Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "circuit" wg kryterium: Wszystkie pola


Tytuł:
Positive continuous – time linear electrical circuit
Autorzy:
Piotrowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/376959.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
positive
non-positive
electrical circuit
linear
Opis:
The positive linear continuous-time systems by the use of the Caputo and conformable fractional calculus are analyzed. The conditions for internally positive systems are presented. For the established electrical circuit, a solution fractional order state-space equation was developed for system with Caputo and conformable fractional derivative (CFD) definition.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 93; 299-309
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An inductive proof of Whitneys Broken Circuit Theorem
Autorzy:
Dohmen, Klaus
Powiązania:
https://bibliotekanauki.pl/articles/743963.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
chromatic polynomial
broken circuit
induction
Opis:
We present a new proof of Whitney's broken circuit theorem based on induction on the number of edges and the deletion-contraction formula.
Źródło:
Discussiones Mathematicae Graph Theory; 2011, 31, 3; 509-515
2083-5892
Pojawia się w:
Discussiones Mathematicae Graph Theory
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical parameter identification of analog integrated circuit reverse models
Autorzy:
Apolloni, B.
Bassis, S.
Mesiano, C.
Rinaudo, S.
Ciccazzo, A.
Marotta, A.
Powiązania:
https://bibliotekanauki.pl/articles/1396732.pdf
Data publikacji:
2011
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Tematy:
analog circuit
circuit model
granular function
cluster
Spice
Opis:
We solve the manufacturing problem of identifying the model statistical parameters ensuring a satisfactory quality of analog circuits produced in a photolithographic process. We formalize it in a statistical framework as the problem of inverting the mapping from the population of the circuit model parameters to the population of the performances. Both parameters and performances are random. From a sample of the latter population we want to identify the statistical features of the former that produce a performance distribution complying with production samples. The key artifact of the solution method we propose consists of describing the above mapping in terms of a mixture of granular functions, where each is responsible for a fuzzy set within the input-output space, hence for a cluster therein. The way of synthesizing the whole space as a mixture of these clusters is learnt directly from the examples. As a result, we have an analytical form of the mapping that approximates complex Spice models in terms of polynomials in the model parameters, and an implicit expression of the distribution law of the induced performances that allows a relatively quick and easy management of the model distribution statistical parameters. This flows into a semiautomatic procedure managing an adaptive composition of different granular modules to cope with the circuit peculiarities. We check the method both on real world manufacturing problems and on ad hoc benchmarks.
Źródło:
Journal of Artificial Intelligence and Soft Computing Research; 2011, 1, 2; 115-134
2083-2567
2449-6499
Pojawia się w:
Journal of Artificial Intelligence and Soft Computing Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finding short-circuit current time based on raw data
Autorzy:
Książkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/376962.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
overcurrent
Scilab
histogram
short-circuit time
Opis:
Series of tests were conducted in which short-circuit current was registered. Four different overcurrent protection devices were used for a set value of prospective current. Based on obtained data the short-circuit time was calculated. In order to obtain this information a procedure was developed. Later it was implemented with the help of numerical computation software Scilab. In this paper results of calculations, the procedure itself and its implementation are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 213-218
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of performing Design FMEA on electronic circuit diagrams
Autorzy:
Karcz, R.
Powiązania:
https://bibliotekanauki.pl/articles/2069239.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
electronic circuit analysis
failure mode
TTAA
Opis:
Existing method of performing FMEA for electronic diagrams is time consuming task. For complex systems analysis of every single component failure mode and its effect deeply involves design team and blocks resources availability for long time. Method presented in this paper allows effective analysis of design failure modes using FMEA approach carrying so called Time to Acceptable Analysis (TTAA) constraint.
Źródło:
Journal of Polish Safety and Reliability Association; 2015, 6, 1; 125--128
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody ograniczania prądów zwarciowych w sieciach niskiego napięcia
The methods of short-circuit currents limitation in LV distribution networks
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/266492.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyłączniki hybrydowe
zwarcia
hybrid circuit breaker
short-circuit current
Opis:
Prezentuje się własności istniejących ograniczników prądu oraz nowego hybrydowego bezstykowego ogranicznika prądów zwarciowych, powstałego przez zastąpienia układu stykowego specjalnym bezpiecznikiem krótkotopikowym. Przedstawia się możliwość zastosowania go do ograniczania skutków łuku awaryjnego w rozdzielnicach nn oraz poprawy jakości energii elektrycznej przez eliminację zapadów napięcia w wyniku bardzo szybkiego wyłączania zwarcia.
A new idea of a hybrid contactless current limiter and the properties of existing current limiter are discussed. On the substitution of a special ultra-short fuse for a contact switch in the hybrid current limiter a new device has been obtained, suitable for fast short-circuit fault cleaning. The fuse role is only to operate at faulty conditions, forcing current transfer into a parallel semiconductor device. Then the current is interrupted at an appropriate instant. They can be helpful in the reduction of voltage dips. It is thought of as a last resort protection in high rated current circuits, like bud bars of switchboards.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 27; 73-78
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamiczne wyznaczanie parametrów elektrycznego obwodu szeregowego
Dynamic evaluation of series electric circuit parameters
Autorzy:
Arendt, R.
Powiązania:
https://bibliotekanauki.pl/articles/266667.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
nieliniowy obwód elektryczny
obwód szeregowy
wartości chwilowe w obwodzie nieliniowym
opis wektorowy obwodu prądu przemiennego
nonlinear electric circuits
series circuit
instantaneous values in nonlinear circuit
vector description of AC circuit
Opis:
Po załączeniu napięcia na skutek istnienia inercji prąd w obwodzie zaczyna narastać od wartości zerowej do znamionowej. W tym czasie narastają spadki napięć na rezystancjach (impedancjach obwodu) bo zaczynają obowiązywać prawa Kirchhoffa. Można utworzyć układ ze sprzężeniem zwrotnym (układ regulacji stałowartościowej bądź nadążnej), który poszukuje parametrów obwodu spełniających prawa Kirchhoffa – elementy nie muszą być liniowe. W artykule przedstawiono omówienie teoretyczne metodyki rozwiązywania obwodów z zastosowaniem programu MatlabSimulink oraz przykłady: nieliniowego obwodu prądu stałego, nieliniowego obwodu dla wartości chwilowych prądu przemiennego oraz liniowych obwodów prądu przemiennego, obliczanych dla wartości wskazowych.
After voltage switch on a current in circuit due to inertia existence start to grow from null to nominal value. Meanwhile grows the resistance (impedance) voltage drops to achieve Kirchhoff’s rule. We can use a circuit with feedback (constant value control system or follow-up control system), which search for circuit parameters fulfilling Kirchhoff’s rules – in such case elements can be nonlinear. In the paper theoretic bases of circuit solutions using Matlab-Simulink program are discussed. Examples of nonlinear circuit of DC, nonlinear circuit for instantaneous values of AC supplied circuit and linear AC circuit evaluated for vector values are presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 15-18
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwarcie awaryjne transformatora
Emergency short-circuit of the transformer
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2135014.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
zwarcie symetryczne
zwarcie awaryjne
prąd udarowy
transformer
symmetrical short-circuit
emergency short-circuit
surge current
Opis:
Jedną z prób przewidzianą w programie badań pełnych transformatorów nowych jest próba zwarcia. Sposób przeprowadzenia tej próby jest opisany w normie PN-EN 60076-5. W eksploatacji transformatorów, które pracują w sieci elektroenergetycznej, zdarzają się także zwarcia przypadkowe. Przykładem jest transformator 16 MVA, 110/20kV z wyjściem kablowym. Kabel został uszkodzony. Powstało zwarcie dwufazowe. Transformator uległ awarii. Bazując na tym przykładzie i wykorzystując schematy zastępcze, obliczono prąd udarowy przy zwarciu symetrycznym i prąd udarowy przy zwarciu dwufazowym. Oceniono przepięcia indukowane przy wyłączaniu prądu zwarcia. Wskazano przyczynę awarii transformatora.
One of the tests included in the test program for complete new transformers is the short-circuit test. The method of carrying out this test is described in the PN-EN 60076-5 standard. In the operation of transformers that operate in the power grid, accidental short-circuits also occur. An example is a 16 MVA, 110 / 20kV transformer with cable outlet. The cable has been damaged. A two-phase short circuit has arisen. The transformer has failed. Based on this example and using equivalent diagrams, the impulse current for symmetrical shortcircuit and the impulse current for two-phase short-circuit were calculated. The induced overvoltage when switching off the short-circuit current was assessed. The cause of the transformer failure is indicated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 11--19
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesne wyłączniki niskiego napięcia
The modern lv circuit-breaker
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/268092.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
interfejsy komunikacyjne
wyłączniki
komunikacja
circuit breaker
diagnostic
communication capability
Opis:
Nowoczesne systemy rozdziału energii stawiają przed wyłącznikami mocy coraz większe wymagania, przekraczające realizację funkcji ochronnych i zabezpieczeniowych. Z tego względu nowoczesna aparatura łączeniowa niskiego napięcia powinna spełniać wymagania stawiane przez zaawansowane systemy sterowania, uwzględniające przede wszystkim: możliwości komunikacyjne, wsparcie programowe, diagnostykę i moSliwości szybkiej archiwizacji zdarzeń.
Modern power distribution systems demand from circuit breaker more and more complex functions going beyond simple protection. Therefore, modern LV switchgear must comply witch new expectation defined by control systems concerning communication, ability of programming, monitoring, recording of events, etc.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 93-96
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorithms for calculation of electrical circuit state
Autorzy:
Timofeev, A.
Ushakov, P.
Powiązania:
https://bibliotekanauki.pl/articles/92838.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach
Tematy:
simulation
electrical circuit
resistor mode
R-2R ladder
Opis:
Algorithms of calculation of a state of an electric circuit with passive components are described. Algorithms are intended for usage in system of simulation of the mixed electronic devices. Each component of a circuit is presented by program model of high complexity. In this article the resistor model is described. Electric voltages in circuit nodes are calculated by method of summation of volt-ampere characteristics. Component models control iterations at calculation of circuit nodes voltage. Results of calculation of voltage in R-2R ladder of the digital-to-analog converter are presented.
Źródło:
Studia Informatica : systems and information technology; 2011, 1-2(15); 5-14
1731-2264
Pojawia się w:
Studia Informatica : systems and information technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of parallel resonance RLCα circuit with supercapacitor
Autorzy:
Walczak, J.
Jakubowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/97419.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
phase resonance
supercapacitor
parallel RLCα circuit
Opis:
The paper describes the results of analysis on the resonance phenomenon in a parallel RLCα circuit with supercapacitor modeled as a fractional-order capacitance. A complex, more accurate fractional-order model has been taken into analysis. Formulas for frequency characteristics and resonance conditions have been derived and presented by simulation studies of the concerned fractional-order system.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 30-37
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Circuit for Balancing Harmonic-Polluted Three-Phase Networks
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262835.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
harmonic analysis
power quality
load balancing
frequency scan
Steinmetz circuit
Opis:
This paper presents a new circuit capable of balancing harmonics-polluted three-phase power networks supplying single-phase loads. It takes into account the negative and positive sequences exhibited by the fifth and seventh harmonics, respectively. The concept extends the relations of the Steinmetz circuit, which are based exclusively on fundamental frequency considerations. The Steinmetz circuit does not, therefore, guarantee the balancing of the different harmonics in the line currents. Furthermore, it can lead to resonances between the capacitive and inductive elements in the two added balancing branches. A procedure for identifying the topology and the circuit parameters of the proposed connection is given. The results of a detailed case study are presented in order to demonstrate the superiority of the proposed circuit over the conventional Steinmetz connection.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2013, 16, 1; 19-24
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka wyłączników niskiego napięcia
The monitoring of LV circuit breaker
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/267606.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyłączniki nn
komunikacja
diagnostyka
circuit breaker
diagnostic
communication capability
Opis:
Nowoczesne systemy rozdziału energii stawiają przed wyłącznikami mocy coraz większe wymagania, przekraczające realizację funkcji ochronnych i zabezpieczeniowych. Z tego względu nowoczesna aparatura łączeniowa niskiego napięcia powinna spełniać wymagania stawiane przez zaawansowane systemy sterowania, uwzględniające przede wszystkim: możliwości komunikacyjne, wsparcie programowe, diagnostykę i możliwości szybkiej archiwizacji zdarzeń.
Modern power distribution systems demand from circuit breaker morę and morę complex functions going beyond simple protection. Therefore, modern LV switchgear must comply witch new expectation defined by control systems concerning communication, ability of programming, monitoring, recording of events, etc.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 97-100
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic equivalent circuit model for unipolar hybrid excitation synchronous machine
Autorzy:
Kupiec, E.
Przyborowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/141541.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hybrid excitation
magnetic equivalent circuit
synchronous machine
Opis:
Lately, there has been increased interest in hybrid excitation electrical machines. Hybrid excitation is a construction that combines permanent magnet excitation with wound field excitation. Within the general classification, these machines can be classified as modified synchronous machines or inductor machines. These machines may be applied as motors and generators. The complexity of electromagnetic phenomena which occur as a result of coupling of magnetic fluxes of separate excitation systems with perpendicular magnetic axis is a motivation to formulate various mathematical models of these machines. The presented paper discusses the construction of a unipolar hybrid excitation synchronous machine. The magnetic equivalent circuit model including nonlinear magnetization curves is presented. Based on this model, it is possible to determine the multi-parameter relationships between the induced voltage and magnetomotive force in the excitation winding. Particular attention has been paid to the analysis of the impact of additional stator and rotor yokes on above relationship. Induced voltage determines the remaining operating parameters of the machine, both in the motor and generator mode of operation. The analysis of chosen correlations results in an identification of the effective control range of electromotive force of the machine.
Źródło:
Archives of Electrical Engineering; 2015, 64, 1; 107-117
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the parallel resonance circuit with supercapacitor
Autorzy:
Walczak, J.
Jakubowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/376990.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
phase and magnitude resonance
parallel RLCα circuit
supercapacitor
Opis:
The article presents an analysis of phase resonance conditions for the parallel RLCα circuit with supercapacitor. Supercapacitors behaviour somehow differs from classic dielectric capacitors, therefore it is necessary to develop their new mathematical models, using fractional - order differential equations. A simple fractional - order supercapacitor model has been assumed, taking into account its internal equivalent series resistance ESR too. A lossless inductance has also been assumed and relations for equivalent admittance and resonance occurence conditions have been derived in the considered parallel RLCα circuit with supercapacitor. The analysis was conducted for different fractional-order parameter α values. Derived relations have been illustrated by simulation examples. The existence of resonance frequency depends largely on the supercapacitor series resistance value.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 77; 93-99
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydraulic circuit control of a steer by wire system
Autorzy:
Voženilek, R.
Maly, M.
Brabec, P.
Powiązania:
https://bibliotekanauki.pl/articles/245341.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
steer by wire
hydraulic circuit
control
Opis:
The future of cars will be connected with "by-wire" systems. The Technical University of Liberec, Department of vehicles and Engines has developed a design of testing equipment for directional control system testing. The objective of the newly designed equipment is to incorporate a wheel with a real tire and a flexible mounting of axle components. The paper describes properties and control of the hydraulic circuit consisting of two double-acting engines with a unilateral piston rod and two proportional valves (Parker D1FP). Each of the front axle wheels is controlled separately. The paper illustrates relationships andpotential of steer-by-wire systems at the experimental equipment. The safe and easy control of a vehicle undoubtedly poses significant requirements. Satisfying them and improving the design to enhance the vehicle's stability have always belonged to the primary objectives of designer s. Consequently, the chassis characteristics, the mechanical features of wheel suspensions, the quality of air suspensions, but also speed control (including brakes) and the vehicle 's directional control have always been emphasised. The objective of the paper was to design a steer-by-wire directional control mechanism with a suitable arrangement. The comparison focuses on various design options to arrange the action members (actuators) of this mechanism.
Źródło:
Journal of KONES; 2009, 16, 4; 477-483
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of fuzzy relational cognitive maps in intelligent modelling the technical systems
Autorzy:
Słoń, G.
Yastrebov, A.
Powiązania:
https://bibliotekanauki.pl/articles/376009.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
cognitive maps
electrical circuit
RLC circuit
Opis:
Certain approach to the modelling dynamic states in technical systems is presented in this paper. This approach lies in a replacing classic differential model with a model based on fuzzy relational cognitive map. Described method is illustrated by practical example of simple electrical RLC circuit. The method of the normalized reference data preparation was described. The process of building a cognitive map with concepts crucial from the modelling purposes point of view was presented also results of such a map teaching process were shown. In the end a partial comparison of simulation results of work of models: classic - based on the set of differential equations and proposed - based on fuzzy relational cognitive map was performed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 175-182
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analog Circuit Based on Computational Intelligence Techniques
Autorzy:
Oltean, G.
Hintea, S.
Şipos, E.
Powiązania:
https://bibliotekanauki.pl/articles/385049.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
analog circuit design
optimization
genetic algorithm
neuro-fuzzy systems
Opis:
This paper presents a new method for analog circuit design optimization. Our approach turns to good account the advantages offered by computational intelligence techniques. Design objectives can be expressed in a flexible manner using fuzzy sets. This way appears the possibility to consider different degrees for requirement achievements and acceptability degree for a particular solution. Neuro-fuzzy systems (universal approximators) are used to model the complex multi-variable and nonlinear circuit performances. These models satisfy two main requirements: high accuracy and low computation complexity. An efficient and robust genetic algorithm does avoiding local minima the exploration of the large, multidimensional solution space in quest for the optimal solution.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 2; 63-69
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of analog circuit based on wavelet transform and neural network
Autorzy:
Wang, Hui
Powiązania:
https://bibliotekanauki.pl/articles/141368.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog circuit
fault diagnosis
neural network
wavelet transform
Opis:
Analog circuits need more effective fault diagnosis methods. In this study, the fault diagnosis method of analog circuits was studied. The fault feature vectors were extracted by a wavelet transform and then classified by a generalized regression neural network (GRNN). In order to improve the classification performance, a wolf pack algorithm (WPA) was used to optimize the GRNN, and a WPA-GRNN diagnosis algorithm was obtained. Then a simulation experiment was carried out taking a Sallen–Key bandpass filter as an example. It was found from the experimental results that the WPA could achieve the preset accuracy in the eighth iteration and had a good optimization effect. In the comparison between the GRNN, genetic algorithm (GA)-GRNN and WPA-GRNN, the WPA-GRNN had the highest diagnostic accuracy, and moreover it had high accuracy in diagnosing a single fault than multiple faults, short training time, smaller error, and an average accuracy rate of 91%. The experimental results prove the effectiveness of the WPA-GRNN in fault diagnosis of analog circuits, which can make some contributions to the further development of the fault diagnosis of analog circuits.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 175-185
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear behavior analysis of split-winding dry-type transformer using a new star model and a coupled field-circuit approach
Autorzy:
Azizian, D.
Powiązania:
https://bibliotekanauki.pl/articles/140907.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coupled field circuit
electromagnetic modeling
split-winding dry-type transformer
nonlinear equivalent circuit
finite element
Opis:
Regarding the importance of short circuit and inrush current simulations in the split-winding transformer, a novel nonlinear equivalent circuit is introduced in this paper for nonlinear simulation of this transformer. The equivalent circuit is extended using the nonlinear inductances. Employing a numerical method, leakage and magnetizing inductances in the split-winding transformer are extracted and the nonlinear model inductances are estimated using these inductances. The introduced model is validated and using this nonlinear model, inrush and short-circuit currents are calculated. It has been seen that the introduced model is valid and suitable for simulations of the split-winding transformer due to various loading conditions. Finally, the effects of nonlinearity of the model inductances are discussed in the following.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 773-787
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum circuit breakers in high and highest voltage grids
Zastosowanie wyłączników próżniowych w sieciach wysokich i najwyższych napięć
Autorzy:
Kubek, P.
Powiązania:
https://bibliotekanauki.pl/articles/397039.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
vacuum insulation technology
vacuum circuit breaker
SF6 circuit breaker
próżniowa technika izolacyjna
wyłącznik próżniowy
wyłącznik SF6
Opis:
Recently, there has been a noticeable increase in the interest of grid operators in the application of vacuum technology in high and highest voltage overhead grids. For many years vacuum circuit breakers have been used in medium voltage grids, but in the past years mainly due to environmental conditions, vacuum technology has been developed also for high and highest voltages. Application of vacuum circuit breakers in high and highest voltage grids requires considering many technical factors that are characterized in this paper. Its main aim is to review the existing solutions of high voltage vacuum circuit breakers and to compare them with SF6 gas circuit breakers. It also discusses technical aspects of high voltage vacuum circuit breakers’ disadvantages and advantages, as well problems of their designing.
W ostatnim czasie można zauważyć intensywny wzrost zainteresowania operatorów sieciowych wykorzystaniem techniki próżniowej w sieciach napowietrznych wysokiego i najwyższego napięcia. Od wielu lat wyłączniki próżniowe są stosowane w sieciach średniego napięcia, jednak w minionych latach głównie ze względu na uwarunkowania środowiskowe technologia próżniowa rozwijana jest także w zakresie wysokich i najwyższych napięć. Zastosowanie wyłączników próżniowych w sieciach WN i NN wymaga uwzględnienia wielu czynników technicznych, które scharakteryzowano w artykule. Głównym celem artykułu jest dokonanie przeglądu istniejących rozwiązań wyłączników próżniowych wysokiego napięcia oraz ich porównanie z wyłącznikami z gazem SF6. Artykuł zawiera także omówienie aspektów technicznych dotyczących wad i zalet, a także problemów dotyczących projektowania wyłączników próżniowych wysokiego napięcia.
Źródło:
Acta Energetica; 2017, 3; 124-130
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czasy wyłączania magnetowydmuchowych wyłączników szybkich prądu stałego
Switching-off Time of Electromagnetic Blow-out High-speed DC Circuit Breaker
Autorzy:
Rojek, A.
Powiązania:
https://bibliotekanauki.pl/articles/215436.pdf
Data publikacji:
2015
Wydawca:
Instytut Kolejnictwa
Tematy:
wyłącznik szybki
zwarcia
czas własny
czas łukowy
high-speed circuit breaker
short-circuit
opening time
arcing time
Opis:
Wyłączniki szybkie są podstawowym zabezpieczeniem przed przepływem nadmiernych wartości prądu w obwodach sieci trakcyjnej oraz zasilanych z niej pojazdów. Prądy zwarciowe muszą być wyłączone w jak najkrótszym czasie, aby zminimalizować ryzyko uszkodzenia chronionych przez wyłączniki elementów systemu zasilania trakcji elektrycznej. Jednym z istotnych parametrów wyłącznika szybkiego jest czas wyłączania prądu, określany od chwili przekroczenia przez prąd nastawy wyzwalacza wyłącznika do chwili wyłączenia prądu. Zakres badań wyłączników szybkich prądu stałego na zgodność z normami obejmuje określenie tego czasu jedynie dla dużych wartości prądu, znacznie przekraczających poziom prądów roboczych, oraz dla prądów o wartości bardzo małej – prądów krytycznych. Podczas eksploatacji wyłączników szybkich najwięcej wyłączeń następuje w wyniku zwarć odległych lub przeciążeń. W celu określenia rzeczywistych czasów wyłączania prądów o wartościach porównywalnych z poziomem nastawy wyzwalacza wyłącznika szybkiego, przeprowadzono badania przy różnych wartościach stałej czasowej obwodu, w wyniku których określono czas łukowy oraz czas własny wyłącznika w zależności od wartości wyłączanego prądu. Badaniom poddano magnetowydmuchowy wyłącznik szybki prądu stałego typu BWS, który jest najczęściej używanym w Polsce wyłącznikiem w podstacjach trakcyjnych i kabinach sekcyjnych.
The high-speed circuit breakers are an essential safeguard against the flow of an excessive current in the circuit overhead line and vehicles being powered by it. The short circuit currents must be switched off as soon as possible to minimize the risk of damage, protected by circuit breakers, elements of an electric traction power supply system. The switching-off time is one of the main parameters of high-speed circuit- breaker. This time is specified from moment of exceeding of the circuit breaker tripping level by the current until cut off the current. The scope of high-speed DC circuit breakers tests for compliance with standards includes determining this time only for large currents, greatly exceeding the operating currents, and the currents of the very small – critical currents. However, during exploitation of high-speed circuit-breakers many faults clearance occurs by distant short-circuits or overloads. In order to determine the actual switching times of currents, which values are comparable with the tripping level researches and tests were performed for different values of the time constant, which were base of specifying value of arcing and opening time, depending on the value of breaking currents. The study involved electromagnetic blow-out high-speed DC circuit breaker BWS type, which is the most common breaker in traction substations and sectioning cabins in Poland.
Źródło:
Problemy Kolejnictwa; 2015, 169; 53-60
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The electromagnetic calculations of complex motion common magnetic circuit electromagnetic converter
Autorzy:
Kamiński, G.
Góralski, P.
Powiązania:
https://bibliotekanauki.pl/articles/140891.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical machines
common magnetic circuit
torque relative error
Opis:
This document contains results of research on complex motion common magnetic circuit electromagnetic converter characteristic that allows making independent axial and rotary shaft motion. The converter in addition to linear-rotary mechanism consists of two drive rotors and one common magnetic circuit excitator. Such a solution allows to reduce volume of the machine and makes it easier to use. The paper cites design intent and possible structure of the device. Phenomenon of common magnetic circuit adverse effect on correct operation of device is discussed. The concept of using relative error as a way to evaluate the influence of that phenomenon in the torques is discussed. Waveforms of determined relative errors for all possible cases is presented. Furthermore the concept of average relative error is defined and its use as a quantitative method of assessing the degree of common circuit impact is indicated. Definition of relative error ripple factor is given, and its usage is shown. Winding inductance calculation based on free FEM application is shown and its influence on control strategy and power system.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 125-133
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Superstabilization of positive linear electrical circuit by state-feedbacks
Autorzy:
Kaczorek, T.
Powiązania:
https://bibliotekanauki.pl/articles/201246.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
positive
electrical circuit
superstability
state-feedback
pozytywny
obwód elektryczny
superstabilność
informacja zwrotna
Opis:
The concept of superstability of positive linear electrical circuits is introduced and its properties are characterized. The superstabilization of positive and nonpositive electrical circuits by state-feedbacks is analyzed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 703-708
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short-circuit duration and dynamic forces in central section of substation
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97305.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
EHV distribution substations
short-circuit dynamic effects
simulations
Opis:
Presented topic is the continuation of investigations concerning the estimation of short-circuit duration when computing the short-circuit effects using probabilistic methods. In the paper, an expanded model of distribution substation for simulation-based analysis of the short-circuit conditions and dynamic effects in the central section of bus-bar is presented. In the model, the operation of protections in the transformer bay has also been considered. The results of simulations aiming to assess the frequency of occurrence of the defined values of short-circuit current, short-circuit duration and dynamic forces are reported. Also, the question: “How the transformer’s protections involved in simulation affect the simulated short-circuit conditions?” has been answered. Computations have been carried out for four different EAZ system configurations.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 220-230
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Arc models for simulating processes in circuits with a SF6 circuit breaker
Autorzy:
Sawicki, Antoni
Powiązania:
https://bibliotekanauki.pl/articles/140610.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
switching arc
high-voltage circuit breaker
Mayr model
Opis:
This paper demonstrates that if a linear dependence of arc dissipated power on power supplied is introduced at an initial stage of analysis, then, with some simplifying assumptions, the classical Mayr model is obtained. Similarly, if this dependence is taken into account in a model with residual conductance, the modified Mayr model is obtained. The study takes into consideration the local phenomenon of sudden voltage drop accompanying linear current decrease occurring in the circuit breaker. To account for this phenomenon, the Dirac delta function and its approximation by a Gaussian function, representing power or enthalpy disturbances, are introduced to the power balance equation. It is demonstrated that both variants yield the same effect, leading to identical differential equations. Macromodels of the circuit-breaker arc are created and connected with the power source circuit with lin- early decreasing current. The results obtained were found to be consistent with experimental data available in the literature. The models presented are based on a fairly uncomplicated 1st order differential equation and offer a straightforward physical interpretation of the phenomena in question.
Źródło:
Archives of Electrical Engineering; 2019, 68, 1; 147-159
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field-circuit analysis of AC machine taking into account stator winding asymmetry
Autorzy:
Pietrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1813709.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
winding asymmetry
induction machine
axial flux
field-circuit model
Opis:
The paper presents the influence of an asymmetry of a stator winding on an axial flux in AC machine. The objective research was performed for selected values of asymmetry. The axial flux was calculated as the sum of flux linkage with stator winding. In order to achieve a magnetic field distribution a dedicated 2D finite element model of AC machine was elaborated. The waveforms of axial flux and torque-time characteristic have been shown. It can be concluded that the asymmetry has significant impact on the axial flux and the pulsation of torque.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 386-392
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two heuristic alghorithms for test point selection in analog circuit diagnoses
Autorzy:
Pułka, A.
Powiązania:
https://bibliotekanauki.pl/articles/221005.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog circuit diagnosis
fault diagnosis
testing
search methods
heuristic optimization
Opis:
The paper presents a heuristic approach to the problem of analog circuit diagnosis. Different optimization techniques in the field of test point selection are discussed. Two new algorithms: SALTO and COSMO have been introduced. Both searching procedures have been implemented in a form of the expert system in PROLOG language. The proposed methodologies have been exemplified on benchmark circuits. The obtained results have been compared to the others achieved by different approaches in the field and the benefits of the proposed methodology have been emphasized. The inference engine of the heuristic algorithms has been presented and the expert system knowledge-base construction discussed.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 115-128
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu warunków zwarciowych na dobór elementów sieci elektroenergetycznej
The influence of short circuit conditions for choosing elements of power network
Autorzy:
Gancarz, A.
Walat, W.
Powiązania:
https://bibliotekanauki.pl/articles/268346.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
sieci rozdzielcze
warunki zwarciowe
wytrzymałość zwarciowa
distribution networks
short-circuit conditions
short-circuit strength
Opis:
W publikacji przedstawiono wpływ warunków zwarciowych na pracę sieci przemysłowych. W szczególności uwzględniono sytuację, w której dochodzi do zmiany mocy zwarciowej lub struktury sieci odbiorczej. W badaniach podjęto próbę wykazania, Se szczegółowe uwzględnienie stopnia obciążenia elementów sieci moSe wpłynąć na ograniczenie nakładów finansowych na jej modernizację.
The paper presents the influence of short-circuit conditions on industrial power networks. It mainly includes the problem of changing short-circuit power or the structure of power network. The attempt was taken to prove that including load range of power network may result in decreasing total costs of modernization.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 46-48
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyłączanie prądów zwarciowych przez wyłączniki szybkie w podstacjach trakcyjnych
Short Circuit Current Breaking by High Speed Circuit Breakers in Traction Substation
Autorzy:
Rojek, A.
Powiązania:
https://bibliotekanauki.pl/articles/215669.pdf
Data publikacji:
2017
Wydawca:
Instytut Kolejnictwa
Tematy:
czas wyłączania
napięcie łuku
badania wyłączników szybkich
breaking time
arc voltage
high speed circuit breakers tests
Opis:
Wyłączniki szybkie stosowane w podstacjach trakcyjnych muszą spełniać wiele wymagań, od czego zależy ich prawidłowa praca, co przekłada się na bezpieczeństwo i ruch pociągów. Z tego względu przed dopuszczeniem do eksploatacji wyłączników szybkich, przechodzą one liczne badana laboratoryjne, w tym na zgodność z wymaganiami norm PN-EN 50123-1 i PN-EN 50123-2. Z uwagi na to, że zapisy norm są ogólne, a czasem mało precyzyjne, wyniki badań laboratoryjnych nie zawsze przekładają się na parametry wyłączników podczas eksploatacji w warunkach rzeczywistych. W  niniejszym artykule przedstawiono zagadnienie dotyczące wyłączania prądu stałego oraz wpływu parametrów obwodu na czas wyłączania. Podano przykład, w którym ten sam typ wyłącznika badany w układzie spełniającym wymagania normy, lecz o różnych parametrach, może spełniać lub nie wymagania dotyczące całkowitego czasu wyłączania. W artykule odniesiono się również do innego parametru wyłącznika szybkiego, jakim jest wartość przepięcia łączeniowego. Przedstawiono wyniki badań, na podstawie których określono wartość maksymalną przepięcia łączeniowego dopuszczalną dla wyłączników pracujących w podstacjach trakcyjnych w Polsce. W ten sposób odniesiono się do zapisów norm branżowych określających, że wartość przepięć łączeniowych może być określona przez użytkownika wyłączników szybkich prądu stałego.
High speed circuit breakers (HSCB) applied in traction substations must meet several requirements conditioning their proper performance, which enhances train safety and traffic. Due to this fact, prior to high speed circuit breakers placing into operation, they are subject to several laboratory tests, including tests checking compliance with PN-EN 50123-1 and PN-EN 50123-2 standards requirements. As many provisions of standards are general and sometimes not very precise, laboratory tests results do not always translate into HSCB parameters in operational use under realistic conditions. The article features the issue concerning DC breaking and the impact of the circuit parameters on the breaking time. An example was given when the same HSCB type was tested in a circuit which meets the standard requirements but bears diff erent parameters and that type can or not fulfi ll the requirements relating to the total breaking time. The article also refers to another HSCB parameter, i.e. the value of switching overvoltage. The test results were presented which were the basis to determine the maximum limit value of switching overvoltage for breakers installed in traction substations in Poland. In this way the reference was made to provisions of industry standards which state that the value of switching overvoltage may be determined by a HSCB user.
Źródło:
Problemy Kolejnictwa; 2017, 177; 51-59
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Let-through energy of miniature circuit breaker in function of phase angle of short-circuit current
Autorzy:
Książkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/377379.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
MCB
let-through energy
Joule's heat
Opis:
Let-through energy (Joule heat) is an important factor in proper protection of electrical installations and devices. Studies were preformed during which the relationship between amount of energy and phase angle of short-circuit current was examined. Typically used miniature circuit breaker was utilized as a protective device. Scilab software for numerical computation was used to calculate the let-through energy based on recorded oscillograms of short-circuit current. Results of this calculations are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 78; 59-64
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stimulus with limited band optimization for analogue circuit testing
Autorzy:
Golonek, T.
Jantos, P.
Rutkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/221641.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analogue circuit testing
faults isolation
evolutionary computations
amplitude spectrum
Opis:
The paper presents an analogue circuit testing method that engages the analysis of the time response to a nonperiodic stimulus specialized for the verification of selected specifications. The decision about the current circuit diagnostic state depends on an amplitude spectrum decomposition of the time response measured during the test. A shape of the test excitation spectrum is optimized with the use of a differential evolution algorithm and it allows for achieving maximum fault coverage and the optimal conditions for fault isolation. Genotypes of the evolutionary system encode the amplitude spectrum of candidates for testing stimuli by means of rectangle frequency windows with amplitudes determined evolutionarily.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 73-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Joule’s heat generated during a short-circuit current flow in function of phase angle
Autorzy:
Książkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/97577.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
Joule's heat
circuit breaker
let-through energy
Opis:
Joule's heat (let-through energy) is an important factor in proper protection of electrical installations and devices. Studies were preformed during which the relationship between amount of energy and phase angle of short-circuit current was examined. Typically used miniature circuit breaker was utilized as a protective device. Scilab software for numerical computation was used to calculate the let-through energy based on recorded oscillograms of short-circuit current. Results of this calculations are presented.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 162-170
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the transient state in a circuit with supercapacitor
Autorzy:
Jakubowska, A.
Walczak, J.
Powiązania:
https://bibliotekanauki.pl/articles/377512.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
fractional-order differential equation
first-order RCα circuit
supercapacitor
Opis:
The paper presents an analysis of the transient state in a simple circuit of RCα class with a supercapacitor. The behavior of supercapacitors differs from that of classic capacitors, which influences voltage and current waveforms in circuits containing them. The waveforms are described by relations of fractional-order integral-differential calculus. A simple fractional-order supercapacitor model, including its series internal resistance, has been assumed for the analysis. The obtained solution of the fractional-order differential equation describing the examined circuit is presented. The impact of different values of the parameter α on the solution has been analyzed too. The derived relations are illustrated by simulation examples for the circuit powered by a DC voltage source. This situation describes the supercapacitor charging process. Its charging time depends mainly on the value of fractional-order parameter α of the supercapacitor.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 81; 71-77
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transitional processes at capacitive currents switching-off by single and double-break interrupters of vacuum circuit breakers
Autorzy:
Lazimov, T.
Saafan, E.
Powiązania:
https://bibliotekanauki.pl/articles/410591.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
vacuum circuit breaker
double-break vacuum interrupters
SF6 circuit breaker
capacitor banks
transient recovery voltage
dielectric strength
breaking capacity
Opis:
Vacuum circuit breaker technology based on double-break vacuum interrupters has become the most requirements of high voltage circuit breakers that not environmentally harmful. The vacuum interrupter has an excellent ability to deal with the steep rising part of the transient recovery voltage, which makes it faster in the current interruption process. This paper presents results of computer simulations conditioned by capacitive currents switching-offs by using single and double interrupters of vacuum circuit breakers. These results demonstrate that use of double-break circuit breakers leads to notable decreasing of switching overvoltages and allows in the same time to meet the dielectric requirements for high voltage vacuum circuit breakers.
Źródło:
Present Problems of Power System Control; 2014, 5; 33-43
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ pomiaru symetrycznych i asymetrycznych prądów zwarciowych z zastosowaniem wielozakresowych przekładników prądowych w warunkach laboratorium zwarciowego
The system of measurement of symmetrical and asymmetric short circuit current with multi range current transformers in conditions of short-circuit testing laboratory
Autorzy:
Babiuch, Michał
Olak, Jan
Powiązania:
https://bibliotekanauki.pl/articles/267651.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
badania zwarciowe
pomiar prądów zwarciowych
przekładnik prądowy
short-circuit test
short-circuit current measurement
current transformer
Opis:
W artykule przedstawiono różne wymagania zawarte w normach przedmiotowych, dotyczące parametrów probierczych dla aparatury elektroenergetycznej i różnych rodzajów badań wykonywanych w laboratorium zwarciowym. Opisano wyposażenie badawczo pomiarowe Zwarciowni Instytutu Elektrotechniki w Warszawie (IEL). Przedstawiono układ pomiaru prądów zwarciowych przy użyciu nowo opracowanych przekładników. Opisano metodę sprawdzenia dokładności przekładników prądowych do pomiaru prądów zwarciowych i zamieszczono przykładowe wyniki i oscylogramy z badań. Układ został wdrożony i jest eksploatowany w Zwarciowni IEL.
The article contains an overview of various requirements for the parameters of the Short-Circuit Testing Laboratory: symmetrical and asymmetrical short-circuit currents, time constant for the disappearance of the constant short-circuit component, asymmetrical peak factor and various types of short-circuit tests performed on various devices operating in power systems, contained in different subject standards . The equipment of the Short-Circuit Testing Laboratory of the Electrotechnical Institute and the modernized test chamber No. 6 is described, equipped with new multi range current transformers and a modern measuring system for short-circuit current. The method of checking the accuracy of current transformers for measuring short-circuit currents is described and example oscillograms are given. The values of the adopted parameters of the transformers and the way of designing the test track are highlighted, enabling the simplification of preparatory works to carry out short-circuit tests and research organization. The article contains electrical diagrams of measurement systems, diagrams of current transformer windings and photograph of modernized test chamber No. 6.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości komunikacyjne nowoczesnych wyłączników niskiego napięcia
The communication capability of modern LV circuit-breaker
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/268030.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyłączniki mocy
diagnostyka
komunikacja
circuit breaker
diagnostic
communication capability
Opis:
Nowoczesne systemy rozdziału energii stawiają przed wyłącznikami mocy coraz większe wymagania, przekraczające realizację funkcji ochronnych i zabezpieczeniowych. Z tego względu nowoczesna aparatura łączeniowa niskiego napięcia powinna spełniać wymagania stawiane przez zaawansowane systemy sterowania, uwzględniające przede wszystkim: możliwości komunikacyjne, wsparcie programowe, diagnostykę i możliwości szybkiej archiwizacji zdarzeń.
Modern power distribution systems demand from circuit breaker more and more complex functions going beyond simple protection. Therefore, modern LV switchgear must comply witch new expectation defined by control systems concernilg communication, ability of programming, monitoring, recording of events, etc.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 25; 91-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On Transformation of a Logical Circuit to a Circuit with NAND and NOR Gates Only
Autorzy:
Baranov, S.
Karatkevich, A.
Powiązania:
https://bibliotekanauki.pl/articles/963932.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
logic synthesis
logic devices
VLSI
minimization
Opis:
In the paper we consider fast transformation of a multilevel and multioutput circuit with AND, OR and NOT gates into a functionally equivalent circuit with NAND and NOR gates. The task can be solved by replacing AND and OR gates by NAND or NOR gates, which requires in some cases introducing the additional inverters or splitting the gates. In the paper the quick approximation algorithms of the circuit transformation are proposed, minimizing number of the inverters. The presented algorithms allow transformation of any multilevel circuit into a circuit being a combination of NOR gates, NAND gates or both types of universal gates.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 3; 373-378
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of hydraulic circuit in mechatronic systems
Stosowanie obwodu hydraulicznego w systemach mechatronicznych
Autorzy:
Tropp, M.
Bastovansky, R.
Powiązania:
https://bibliotekanauki.pl/articles/101808.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
hydraulic circuit
MATLAB
simulation
obwód hydrauliczny
symulacje
Matlab
Opis:
This paper focuses on the calculations of basic variables of the hydrostatic circuits in the mechatronic systems. These calculations are important for machines used for forming materials by means of great forces, e.g. hydraulic press. Due to differences in equipment design, lack of a universal method of calculation is noticeable. It is necessary to determine the coefficients required for the calculations in an experimental way.
Tematem niniejszego artykułu jest obliczanie zmiennych podstawowych w obwodach hydrostatycznych w systemach mechatronicznych. Obliczenia te są wykonywane w mechatronice i wykorzystywane w maszynach do formowania materiałów za pomocą wielkich sił (prasa hydrauliczna). Zauważalny jest brak uniwersalnej metody obliczeń ze względu na różnice w konstrukcji urządzeń, stąd też konieczne jest wyznaczanie potrzebnych do obliczeń współczynników w sposób eksperymentalny.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2016, 2, 1; 5-10
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania obwodu pneumatycznego z korektorem siły hamowania pojazdu
Research of the pneumatic circuit with the proof-reader of the brake force of the vehicle
Autorzy:
Czaban, J.
Miatluk, M.
Powiązania:
https://bibliotekanauki.pl/articles/262927.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
obwód hamulcowy
obwód pneumatyczny
siła hamowania
zawór korygujący
brake circuit
corrector valve
pneumatic circuit
Opis:
W pracy przedstawiono metodykę wyznaczania i identyfikacji charakterystyk statycznych i dynamicznych zaworu korygującego siłę hamowania 975 002. Otrzymane wyniki wykorzystano w obliczeniach dynamicznych obwodu hamulcowego samochodu ciężarowego z zaworem korygującym siłę hamowania. Przedstawiono wykresy przebiegu ciśnień w różnych punktach obwodu hamulcowego.
The paper presents the methodic of getting and identification of static and dynamic characteristics of the 975 002 corrector valve of the brake force. The obtained results were applied in dynamic calculations of the truck brake circuit with corrector valve of the brake force. Graphs of pressures changes in different points of the brake circuit are presented.
Źródło:
Archiwum Motoryzacji; 2008, 2; 121-132
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie fizyczne toru przewodowego przy ocenie iskrobezpieczeństwa obwodów i systemów elektrycznych
Metallic circuit physical modeling for spark-proof safety assessment of electric circuits
Autorzy:
Skoropacki, W.
Powiązania:
https://bibliotekanauki.pl/articles/340945.pdf
Data publikacji:
2003
Wydawca:
Główny Instytut Górnictwa
Tematy:
iskrobezpieczeństwo
obwód elektryczny
system elektryczny
tor przewodowy
iskiernik
spark-proof safety
electric circuit
electric system
metallic circuit
spark gap
Opis:
Jedną z metod określenia poziomu iskrobezpieczeństwa obwodów i systemów elektrycznych zawierających tory przewodowe (linie długie) jest metoda polegająca na wykorzystaniu iskiernika. W celu właściwego przeprowadzenia badań za pomocą iskiernika należy posługiwać się prawidłowym modelem fizycznym toru przewodowego (macierzystego), w postaci kaskadowego połączenia pasywnych symetrycznych czwórników, typu "T", "Π" i "X", zbudowanych ze skupionych elementów R, L, C, których wartości są równe odpowiednim parametrom toru macierzystego. Czwórniki te najczęściej symulują odcinki toru macierzystego o znanych parametrach jednostkowych Rj, Lj, Cj i Gj. Modelowanie toru przewodowego za pomocą pasywnych czwórników wymaga spełnienia dwóch kryteriów: - sumaryczna wartość elektromagnetycznej energii zgromadzonej w elementach reaktancyjnych czwórników zastępczych powinna być adekwatna do wartości energii zgromadzonej w naturalnym torze przewodowym, - charakterystyki amplitudowo-częstotliwościowe kaskady czwórników zastępczych i toru przewodowego powinny być zbieżne w wymaganym paśmie pulsacji, tak w stanie jałowym, jak i w stanie dopasowania falowego. Określono podstawowe warunki zastępowania toru przewodowego minimalną liczbą pasywnych czwórników, przy zachowaniu adekwatnej zdolności gromadzenia i przekazywania energii elektrycznej do punktu komutacji awaryjnej. Ocena modelu fizycznego została dokonana na podstawie określenia zbieżności charakterystyk amplitudowo-częstotliwościowych kaskady czwórników zastępczych i odcinka toru przewodowego w stanie jałowym i w stanie dopasowania falowego. Ustalono, że zastępowanie jednostkowego odcinka toru przewodowego jednym czwórnikiem nie odwzorowuje parametrów falowych toru macierzystego kabla w stanie jałowym i dopasowania falowego, co jest konieczne w badaniach, za pomocą iskiernika zapalności obwodu elektrycznego z torem przewodowym, ponieważ podczas wyładowania elektrycznego rezystancja kanału wyładowania zmienia się od 0 do ∞ (przy awaryjnym rozwarciu obwodu) lub od ∞ do 0 (przy awaryjnym zwarciu). Zakres pulsacji, dla którego wymagana jest zbieżność charakterystyk amplitudowo-częstotliwościowych toru przewodowego i kaskady czwórników zastępczych powinien być określany dla każdego konkretnego przypadku z uwzględnieniem parametrów źródła zasilania, zabezpieczenia przeciwwybuchowego i środowiska wybuchowego.
One of the methods used for determination of spark-proof safety of electric systems including metallic circuits is based on the use of spark gap. An appropriate physical model of metallic circuit is indispensable for that purpose. Such model is built in the form of a cascade of two-terminal-pair networks of "T", "Π" and "X" type, consisting of lump R, L, C elements and having parameters equal to the respective parameters of the metallic circuit. Usually two-terminal-pair networks emulate sections of metallic circuit whose unitary parameters Rj, Lj, Cj and Gj are known. The two following criteria should be met in order to secure a good emulation of metallic circuit by passive two-terminal-pair networks: - sum of electromagnetic energy accumulated in elements of two-terminal-pair networks should be adequate to the value of energy accumulated in the natural metallic circuit, - attenuation-frequency diagrams of the cascade of two-terminal-pair networks and the diagrams of metallic circuit should converge in the requested range of pulsation both in the idle state and in the state of impedance matching, The essential conditions were determined for metallic circuit modeling by minimal number of two-terminal-pair networks with ability preserved for accumulation of electric energy and its transfer to the emergency commutation point. The assessment of physical model was carried out by determination of convergence of diagrams of a section of the metallic circuit and a cascade of two-terminal-pair networks both the idle state and in the state of impedance matching. It has been determined that the substitution of a single section of the metallic circuit by one two-terminal-pair network in spark gap testing does not represent adequately wave parameters of metallic circuit of the cable both in the idle or impedance matching states. It is so because the resistance of the discharge channel changes from 4 to 0 (in the case of emergency circuit opening) or from 0 to 4 (in the case of emergency shorting). The pulsation range for which convergence is required of attenuation-frequency diagrams of a cascade of two-terminal-pair networks and diagrams of a metallic circuit should be determined in each particular case.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2003, 2; 33-48
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prioritization approach for circuit breakers to equip with condition monitoring devices
Autorzy:
Karimabadi, Ali
Hajiabadi, Mohammad Ebrahim
Kamyab, Ebadollah
Powiązania:
https://bibliotekanauki.pl/articles/140753.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
circuit breakers
condition monitoring
outage rate
reliability
smart sensor
Opis:
Circuit Breakers (CBs) play an important role in ensuring the safe operation of protection systems. Condition Monitoring (CM) devices are widely implemented to extend lifetime, and to improve the maintenance quality. The present paper proposes a cost-based prioritization approach for CBs in a network equipped with CM devices. To this end, a mathematical formulation is developed for the categorization and modeling of equipment failures based on their severity. This formulation quantifies the effect of the CM devices on the outage rate of the equipment. The reliability parameters of the substations 400/132/20 KV, including the failure rate, λ, average repair time, r, average outage time, U, substations, in two status of without CM and with CM of the CBs are calculated. These parameters are calculated implementing a minimal cut-set method. The outage rate of equipment with and without the CM devices is used to determine the effect of the CM devices on the reliability of the network. Finally, the prioritization of substations to install the CM devices on the CBs has been investigated in terms of the Expected Energy Not Supplied (EENS) and costs of CM. To verify the effectiveness and applicability of the method, the proposed approach is applied to the CBs in the power transmission network in the Khorasan Regional Electricity Company (KREC) in Iran.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 403-422
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A field-circuit model of the hybrid magnetic bearing
Autorzy:
Wajnert, Dawid
Powiązania:
https://bibliotekanauki.pl/articles/140245.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dynamic simulation
field-circuit model
hybrid magnetic bearing
symulacja dynamiczna
model polowo-obwodowy
hybrydowe łożysko magnetyczne
Opis:
The paper presents a simulation model of the hybrid magnetic bearing dedicated to simulations of transient state. The proposed field-circuit model is composed of two components. The first part constitutes a set of ordinary differential equations that describes electrical circuits and mechanics. The second part of the simulation model consists of parameters such as magnetic forces, dynamic inductances and velocity-induced voltages obtained from the 3D finite element analysis. The MATLAB/Simulnik software was used to implement the simulation model with the required control system. The proposed field-circuit model was validated by comparison of time responses with the prototype of the hybrid magnetic bearing.
Źródło:
Archive of Mechanical Engineering; 2019, LXVI, 2; 191-208
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical Modeling of Stress in Circuit Cards Represented by Mechanical Oscillatory Systems
Autorzy:
Kovtun, Igor
Goroshko, Andrii
Petrashchuk, Svitlana
Powiązania:
https://bibliotekanauki.pl/articles/2022447.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
oscillatory system
dynamic force
stress
deflection
circuit card
resonance
Opis:
The represented paper is aimed at stress calculation in circuit cards with their representation as a type of mechanical oscillatory systems in purpose of their strength assessment especially in resonance conditions. Three types of oscillatory systems are researched: single-mass; multiple mass and oscillatory system with uniformly distributed mass. In all types the cylindrical bending of circuit cards is considered to be a set of beam-strips with rectangular cross-sections so their stress calculation is performed by conventional methods applied in strength of materials and civil engineering. Mathematical model has been developed for maximal dynamic stress and deflection estimation in circuit card assemblies represented by unique oscillatory system as prismatic beam set on two oscillating supports under inertial resonance excitation generated by constant dynamic force. Comparative analysis of mathematical modeling, MatLab simulation and experimental determination of maximal dynamic stress and deflection accomplished for three types of oscillatory systems verified proximity of obtained results. Single-mass oscillatory system is proposed as equivalent to multiple mass or uniformly distributed oscillatory systems on condition of their equal mass, geometric, elastic and dissipation characteristics in resonance frequency correspondent to the main mode of oscillation, so mathematical model designed for single-mass oscillatory system is recommended for strength and stiffness assessment in engineering calculations where possible difference in determination of stress in equivalent systems can used as safety factor.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 1; 303-315
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Values of short-circuit duration and dynamie forces during short-circuits in the EHV substations: simulation-based investigations
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97694.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
short-circuit duration
EHV substations
simulation
Opis:
Presented question is the continuation of investigations concerning the short-circuit duration’s estimation in the short-circuit effect calculations using the probabilistic method. In the paper, the developed simulation model of the short circuit duration under the disturbing conditions just in the distribution substation is presented. The model development was based on the analysis of operation of the automatic power protections EAZ and circuit-breakers in the EHV substations during short-circuits. The results of simulation investigations aiming to estimate the frequency of occurrence of the defined short-circuit duration are reported. The calculations have been carried out for different configurations of the EAZ system. For selected spans in the 220 kV substation, probabilistic analysis of dynamic forces accompanying the in-substation faults has been carried out. Also, the way of the short-circuit duration’s estimation when calculating the dynamic effects of the fault current flow basing on an assumed risk value has been proposed.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 171-184
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analog Circuit Fault Classification Using Improved One-Against-One Support Vector Machines
Autorzy:
Cui, J.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/220569.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog circuit
fault classification
Support Vector Machines Classifier
fault dictionary
kernel parameter
Opis:
This paper presents a novel strategy of fault classification for the analog circuit under test (CUT). The proposed classification strategy is implemented with the one-against-one Support Vector Machines Classifier (SVC), which is improved by employing a fault dictionary to accelerate the testing procedure. In our investigations, the support vectors and other relevant parameters are obtained by training the standard binary support vector machines. In addition, a technique of radial-basis-function (RBF) kernel parameter evaluation and selection is invented. This technique can find a good and proper kernel parameter for the SVC prior to the machine learning. Two typical analog circuits are demonstrated to validate the effectiveness of the proposed method.
Źródło:
Metrology and Measurement Systems; 2011, 18, 4; 569-582
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of snubber circuit design for SiC power MOSFET devices
Autorzy:
Niewiara, Ł. J.
Skiwski, M.
Tarczewski, T.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/97236.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
DC\DC converter
snubber circuit
SiC MOSFET
Opis:
In this paper a design process of snubber circuit for DC\DC converter is presented. Computer simulation and experimental tests were carried out. Due to the presence of parasitic LC (inductance and capacitance) circuit in the power stage, it is necessary to use an additional snubber circuit for voltage overshoot and oscillations reduction. A simulation model of the converter with parasitic circuit was designed. Six topologies of snubber circuits (C, single C, RC, single RC, RCD, single RCD) were investigated in simulation tests. Simulation model of the proposed system has been investigated in Matlab/Simulink/PLECS environment. Input signal parameters like voltage overshoot, rise time, fall time were compared for considered snubber circuits. Experimental tests were carried out for the best simulation results. It confirm the proper choice of snubber circuit.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 120-131
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of fractional electrical circuit with rectangular input signal using Caputo and conformable derivative definitions
Autorzy:
Piotrowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/140842.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fractional order system
Caputo definition
conformable fractional definition
fractional electrical circuit
Opis:
An analysis of a given electrical circuit using a fractional derivative. The statespace equation was developed. The dynamics of tensions described by Kirchhoff’s laws equations. The paper used the definition of the integral derivative Caputo and CDF conformable fractional definition. An electrical circuit solution using Caputo and CDF definitions for rectangular with zero initial conditions was developed. The results obtained using the Caputo and CDF definitions were compared. The solutions are shown for capacitor voltages, for fractional derivative orders of 0.6, 0.8, 1. The results were compared using graphs.
Źródło:
Archives of Electrical Engineering; 2018, 67, 4; 789-802
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unidirectional Protection Strategy for Multi-terminal HVDC Grids
Autorzy:
Mokhberdoran, A.
Silva, N.
Leite, H.
Carvalho, A.
Powiązania:
https://bibliotekanauki.pl/articles/136202.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
DC circuit breaker
HVDC
Protection Device
voltage source converter (VSC)
Short-circuit
Opis:
Protection issue is identified as the main drawback of emerging multi-terminal HVDC grids. Multi-terminal HVDC grid demands fast short circuit fault current interruption. Fast DC circuit breakers as a promising solution can be implemented as either bidirectional or unidirectional devices. In addition to less implementation cost, the unidirectional DC circuit breakers have less power losses as compared to the bidirectional devices. A protection strategy for multi-terminal HVDC grid based on unidirectional breaking devices is discussed and assessed in this paper. The performance of unidirectional protection strategy is examined under different fault scenarios in a fourterminal MMC-HVDC grid model. Furthermore, the impacts of unidirectional protection strategy on power converters and also current interruption and surge arrester ratings of the DC circuit breakers are discussed.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 58-65
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analogowo-cyfrowy rejestrator szybkich obiektów
Autorzy:
Madej, W.
Powiązania:
https://bibliotekanauki.pl/articles/118329.pdf
Data publikacji:
2014
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
układy analogowo-cyfrowe
filtracja analogowa
filtracja cyfrowa
układ dopasowujący
algorytm
analog-to-digital circuit
analog filtering
digital filtering
matching circuit
algorithm
Opis:
W pracy przedstawiono praktyczną realizację analogowo-cyfrowego systemu rejestracji szybkich obiektów. Przez szybkie obiekty rozumie się przeciwlotnicze pociski artyleryjskie o kalibrach powyżej 23 mm. System został zbudowany z wykorzystaniem stacji radiolokacyjnej ZRP-1 „WAZA” oraz sprzężonego z nią komputera klasy IBMPC wyposażonego w kartę wejść – wyjść analogowych. Przedstawiono część analogową systemu oraz algorytm obliczeń realizowanych w komputerze traktowany jako cyfrową obróbkę sygnałów. Na koniec omówiono wizualizację wyników rejestracji. System ten był już wielokrotnie wykorzystywany podczas badań nowych przeciwlotniczych zestawów artyleryjskich.
In this work practical realization of the analog to digital recording system of the fast object are presented. As a fast object the anti-aircraft artillery guns whit caliber 23 mm or greater are understanding. The system was build with use of the radar station ZRP-1 “WAZA” coupling with computer IBMPC appointed an analog inputoutput adapter. The analogue section and the algorithm of the computation realizing in the computer, treating as digital data processing, are presented. At last visualisation of the recording results are discuss. Presented system was repeatedly used during a new anti-aircraft artillery systems research.
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2014, 6; 15-23
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lighting device parameters influence on signal circuit safety in interlocking systems
Autorzy:
Nagy, P.
Ždánsky, J.
Powiązania:
https://bibliotekanauki.pl/articles/393479.pdf
Data publikacji:
2010
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
bezpieczeństwo układu
SRK
semafor świetlny
interlocking system
signal circuit safety
colour light signal
Opis:
Signal circuits are an important part of the interlocking system. The main role of the signalling circuit is to switch the required signal aspects and signal checking. A signal is an interface between the interlocking system and a driver of the railway vehicle. Light bulbs are mostly used as a light source in most types of interlocking systems. It is possible to think about alternative light sources within the context of modernisation of the interlocking systems. The use of alternative light sources using must not cause signal circuit safety degradation. The article deals with problems of light bulbs replacement for another light source in AŽD 71 type relay interlocking in the Railways of Slovak Republic.
Źródło:
Archives of Transport System Telematics; 2010, 3, 3; 9-13
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Implementation of the Parallel Scrambler Scheme for the IEEE 802.11 Standard
Autorzy:
Kudinov, A.
Antimirov, Y.
Tyshchenko, I.
Popova, M.
Cherepanov, A.
Powiązania:
https://bibliotekanauki.pl/articles/226358.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
scrambler
sequential circuit
parallel circuit
Opis:
This article is devoted to the development of the scrambler circuit. Nowadays, new WiFi standard IEEE 802.11 is being put into operation, so that there is a huge need in modern, energy-efficient algorithms, which will be used in the data transmission. Consequently, some of the scrambler circuits, which could be implemented for the IEEE 802.11 standard are described with its comparison. In addition, an example in Python is given for readers to use it in their researches.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 1; 91-94
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental verification of signal propagation in automotive ignition cables modelled with distributed parameter circuit
Autorzy:
Różowicz, Sebastian
Zawadzki, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/141016.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed parameter circuit
ignition cable
spark plug
ignition system
spark discharge
Opis:
The paper analyses the possibilities of treating the ignition cable in the internal combustion engine as a distributed parameter system. It presents the experimental verification of computer simulations of signal propagation generated by ignition systems in the ignition cables, modelled by the distributed parameter system. The tests conducted to determine the wave parameters of ignition cables, as well as the results of numerical simulations and their experimental verifications, are presented. It is concluded that the modelling of the ignition cable by means of a long line gives positive results that can be used for the design of a spark plug with impedance equal to wave impedance of the ignition cable.
Źródło:
Archives of Electrical Engineering; 2019, 68, 3; 667-675
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stator winding inter-turn short-circuit modelling of a squirrel-cage induction motor
Autorzy:
Radecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1193158.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
squirrel-cage induction motor modelling
induction motor faults
stator winding inter turn short-circuit
Opis:
A mathematical model of a squirrel-cage induction motor with inter-turn short-circuits in stator phases is presented in this paper. In the proposed mathematical model an extent and angular localization of short-circuit faults are determined using a simple form of short-circuit coefficient matrices. The model does not require any additional motor parameters than those that are required for conventional model of healthy induction motor. Comparative results obtained through computer simulations and from a laboratory test-stand with 2.2 kW induction motor are contained in the article. The results obtained validate the proposed extended mathematical model of a squirrel-cage induction motor with inter-turn short-circuit of stator windings.
Źródło:
Power Electronics and Drives; 2016, 1, 36/1; 139-148
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
VHDL-AMS Models for Current Conveyor Based Monolithic Operational Amplifiers
Autorzy:
Pandiev, Ivailo M.
Powiązania:
https://bibliotekanauki.pl/articles/398082.pdf
Data publikacji:
2018
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
analog circuits
CCII
CCCII
CFOA
integrated circuit modelling
VHDL-AMS
circuit simulation
układy analogowe
symulacja obwodowa
Opis:
This paper focuses on analysis and behavioral modeling of second generation positive and negative current conveyors (CCII+s, CCII‒s), as well current-controlled current conveyors (CCCIIs). On the basis of the proposed CCII+ model improved behavioral models for three-terminal and four-termi-nal monolithic CFOAs are created. The models are developed by using VHDL analog and mixed-signal (VHDL-AMS) language and the descriptions are adapted to the SystemVision (version 5.5) simulation program, which is a part of the Mentor Graphics system. The proposed models simulate static and dynamic para-meters for differential and common-mode input signals at room temperature, including the parameters input offsets, accurate input impedances, non-dominant poles at differential input signals, AC common-mode rejection, PSRR effects, output impe-dances, slew rate limiting and terminal voltage/current operating ranges. The modeling parameters are extracted for commercially available four-terminal CFOA AD844A and CCCII OPA860 by analyzing semiconductor data books or through characterization measurements. For the validation process simulation and experi-mental results for sample electronic circuits are given.
Źródło:
International Journal of Microelectronics and Computer Science; 2018, 9, 1; 34-46
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DC Large-Scale Simulation of Nonlinear Circuits on Parallel Processors
Autorzy:
Udave, D. E. C.
Ogrodzki, J.
de Anda, G. M. A.
Powiązania:
https://bibliotekanauki.pl/articles/226087.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
circuit simulation
parallel computation
DC analysis
circuit decomposition
Opis:
Newton-Raphson DC analysis of large-scale nonlinear circuits may be an extremely time consuming process even if sparse matrix techniques and bypassing of nonlinear models calculation are used. A slight decrease in the time required for this task may be enabled on multi-core, multithread computers if the calculation of the mathematical models for the nonlinear elements as well as the stamp management of the sparse matrix entries is managed through concurrent processes. In this paper it is shown how the numerical complexity of this problem (and thus its solution time) can be further reduced via the circuit decomposition and parallel solution of blocks taking as a departure point the Bordered-Block Diagonal (BBD) matrix structure. This BBD-parallel approach may give a considerable profit though it is strongly dependent on the system topology. This paper presents a theoretical foundation of the algorithm, its implementation, and numerical complexity analysis in virtue of practical measurements of matrix operations.
Źródło:
International Journal of Electronics and Telecommunications; 2012, 58, 3; 285-295
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A control method of fault current in MT-HVDC grid based on current limiter and circuit breaker
Autorzy:
Wang, Sihua
Zhao, Lei
Zhou, Lijun
Powiązania:
https://bibliotekanauki.pl/articles/1955197.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bipolar short circuit
fault current limiting
hybrid DC circuit breaker
ultiterminal HVDC grid
zwarcie bipolarne
ograniczanie prądu zwarciowego
hybrydowy wyłącznik prądu stałego
ultraliniowa sieć HVDC
Opis:
In order to realize selective isolation of fault lines in multi-terminal high voltage DC (MT-HVDC) grids, it is necessary to ensure that the sound lines can still transmit power normally after the grounding fault occurs in a DC power network. If the fault line needs to be cut before the converter is blocked, a DC circuit breaker (DCCB) with large switching capacity is often required. At present, the extreme fault over-current and the high cost of DCCBs have become the prominent contradiction in MT-HVDC projects. Reducing the breaking stress of power electronic devices of the circuit breaker and controlling its cutting-off time are the major difficulties in this research field. In this paper, a topology of a hybrid DCCB with an inductive current limiting device is proposed. By analyzing its working principle, the calculation method of key parameters is given, and a four-terminal HVDC grid is built in a PSCAD/EMTDC platform for fault simulation. The results show that compared with the traditional circuit breaker, this topology can effectively limit the rising speed and maximum current of fault current when the system fails, and quickly remove the fault line, so as to meet the suppression requirement of the HVDC system for fault current.
Źródło:
Archives of Electrical Engineering; 2021, 70, 4; 907-923
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczanie prądu początkowego zwarcia w sieciach SN według normy PE-EN 60909
Calculation of initial short-circuit currents in medium voltage networks acording to the standard PNEN60909
Autorzy:
Księżyk, K.
Zdun, T.
Powiązania:
https://bibliotekanauki.pl/articles/267769.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
obliczenia zwarciowe
początkowy prąd zwarciowy
modele elementów
short-circuit calculations
initial short-circuit current
electrical equipment models
Opis:
Wyznaczanie wielkości zwarciowych należy do najczęściej wykonywanych analiz sieciowych. Przeprowadzanie tych obliczeń powinno być zgodne z obowiązując normą PN-EN 60909. W referacie zostały opisane modele podstawowych elementów sieci wraz ze sposobem wyznaczania ich parametrów impedancyjnych z uwzględnieniem współczynników korygujących wprowadzonych przez normę. Przedstawiono wyniki obliczeń początkowego prądu zwarcia dla przykładowej sieci SN oraz porównano je z wynikami uzyskanymi bez uwzględniania współczynników poprawkowych.
Determining the short-circuit currents is usually conducted network analyzes. An important feature of this calculation is carried out according to the recommendations of the standard PN EN 60909. This paper describes the models of the basic elements of the network with the method of determining the impedance parameters including correction factors introduced by the standard. Thevenin method connected with nodal method are presented and used to determine the initial short-circuit for the example medium voltage network. Results are compared with the ones obtained without taking into account the correction factors.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 75-78
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of short-circuit ac currents on electrical contact resistance of low voltage relays
Autorzy:
Książkiewicz, A.
Janiszewski, J.
Batura, R.
Powiązania:
https://bibliotekanauki.pl/articles/378117.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical contact resistance
ECR
short-circuit current
low voltage relays
Opis:
Electromagnetic relays can be exposed to many hazardous phenomena during their lifetime. The most vulnerable part of an relay to their adverse effects are his electrical contacts. One of many parameters describing electrical contacts is their resistance. In this article experiments regarding the impact of short-circuit currents at make on electrical contact resistance of electromagnetic relays is described.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 70; 99-103
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new 4-D dynamical system exhibiting chaos with a line of rest points, its synchronizationand circuit model
Autorzy:
Vaidyanathan, Sundarapandian
Sambas, Aceng
Zhang, Sen
Powiązania:
https://bibliotekanauki.pl/articles/229283.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chaos
chaotic systems
circuit design
synchronization
Opis:
A new 4-D dynamical system exhibiting chaos is introduced in this work. The proposed nonlinear plant with chaos has an unstable rest point and a line of rest points. Thus, the new nonlinear plant exhibits hidden attractors. A detailed dynamic analysis of the new nonlinear plant using bifurcation diagrams is described. Synchronization result of the new nonlinear plant with itself is achieved using Integral Sliding Mode Control (ISMC). Finally, a circuit modelusing MultiSim of the new 4-D nonlinear plant with chaos is carried out for practical use.
Źródło:
Archives of Control Sciences; 2019, 29, 3; 485-506
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchronous Generator Model with Nonlinear Magnetic Circuit
Model generatora synchronicznego uwzględniający nieliniowość obwodu magnetycznego
Autorzy:
Spałek, D.
Powiązania:
https://bibliotekanauki.pl/articles/396954.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
synchronous generator
nonlinear magnetic circuit
numerical model
generator synchroniczny
nieliniowy obwód magnetyczny
model symulacyjny
Opis:
A synchronous generator with voltage controller is a system whose work describes the ordinary differential equation set for the equivalent circuits. For the nonlinear magnetic circuit of a synchronous generator (stator and rotor saturation) the differential set is nonlinear. The solution of such a problem needs to develop the appropriate model for numerical simulations of the generator. First of all, the generator model type e.g. (1,1), (2,2), (3,3) or other should be chosen. Furthermore, the equivalent parameters for the model of synchronous generator should be chosen. The nonlinearity of magnetic circuit leads to changes of some equivalent parameters and additional numerical computations. There is a numerical program developed in C++ for simulations of transients in order to investigate their sensitivity to generator nonlinearity (saturation effect) and equivalent parameters values. The described program (available at www.elektr.polsl.pl/dspalek/) enables to decide whether the nonlinearity for d/q axis should be taken into account and which equivalent parameter are of high importance. Subsequently, the presented model leads to conclusions on which parameters should influence significantly synchronous generator work in a power system.
Generator synchroniczny wraz z układem wzbudzenia jest obiektem, którego pracę opisuje układ równań różniczkowych zwyczajnych. Przy uwzględnieniu nasycania się obwodu magnetycznego maszyny synchronicznej układ równań różniczkowych jest nieliniowy. Rozwiązanie takiego układu równań różniczkowych wymaga zaproponowania schematu zastępczego dla potrzeb symulacji pracy generatora. Po pierwsze powinien zostać wybrany model generatora synchronicznego np. (1, 1), (2, 2), (3,3) lub inny. Następnie należy dobrać parametry dla obwodów zastępczych generatora. Uwzględnienie nieliniowości obwodu magnetycznego prowadzi do zmian parametrów zastępczych w funkcji prądów i prowadzi do dodatkowych obliczeń przy rozwiązywaniu układu równań różniczkowych. Opracowany został autorski program napisany w języku C++, który pozwala na symulację pracy stanów nieustalonych oraz ocenę wrażliwości otrzymywanych przebiegów na: nieliniowość obwodu i parametry schematu zastępczego. Omawiany symulator numeryczny (dostępny na stronie: www.elektr.polsl.pl/dspalek/) pozwala na szybką ocenę wrażliwości na dany parametr obwodu i nieliniowości w osi d/q, a w konsekwencji pozwala podejmować decyzje, czy należy dokonywać dokładniejszej identyfikacji parametrów modelu dla opisu pracy generatora w systemie energetycznym.
Źródło:
Acta Energetica; 2013, 4; 144-157
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new chaotic system with axe-shaped equilibrium, its circuit implementation and adaptive synchronization
Autorzy:
Vaidyanathan, S.
Sambas, A.
Mamat, M.
Powiązania:
https://bibliotekanauki.pl/articles/230023.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chaos
chaotic systems
curve equilibrium
Lyapunov exponents
circuit design
synchronization
Opis:
In the recent years, chaotic systems with uncountable equilibrium points such as chaotic systems with line equilibrium and curve equilibrium have been studied well in the literature. This reports a new 3-D chaotic system with an axe-shaped curve of equilibrium points. Dynamics of the chaotic system with the axe-shaped equilibrium has been studied by using phase plots, bifurcation diagram, Lyapunov exponents and Lyapunov dimension. Furthermore, an electronic circuit implementation of the new chaotic system with axe-shaped equilibrium has been designed to check its feasibility. As a control application, we report results for the synchronization of the new system possessing an axe-shaped curve of equilibrium points.
Źródło:
Archives of Control Sciences; 2018, 28, 3; 443-462
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of Initial Short-Circuit Currents in Medium Voltage Networks According to the Standard PN-EN 60909
Obliczanie prądu początkowego zwarcia w sieciach sn według normy PN-EN 60909
Autorzy:
Księżyk, K.
Zdun, T.
Powiązania:
https://bibliotekanauki.pl/articles/397330.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
short-circuit calculations
initial short-circuit current
electrical equipment models
obliczenia zwarciowe
początkowy prąd zwarciowy
modele elementów
Opis:
Determining the short-circuit currents is usually conducted by network analyses. An important feature of this calculation is carried out according to the recommendations of the standard PN EN 60909. This paper describes the models of the basic elements of the network with the method of determining the impedance parameters including correction factors introduced by the standard. Thevenin’s method connected with the nodal method are presented and used to determine the initial short-circuit for the example medium voltage network. Results are compared with the ones obtained without taking into account the correction factors.
Wyznaczanie wielkości zwarciowych należy do najczęściej wykonywanych analiz sieciowych. Przeprowadzanie tych obliczeń powinno być zgodne z obowiązującą normą PN-EN 60909. W artykule zostały opisane modele podstawowych elementów sieci wraz ze sposobem wyznaczania ich parametrów impedancyjnych z uwzględnieniem współczynników korygujących wprowadzonych przez normę. Przedstawiono wyniki obliczeń początkowego prądu zwarcia dla przykładowej sieci SN oraz porównano je z wynikami uzyskanymi bez uwzględniania współczynników poprawkowych.
Źródło:
Acta Energetica; 2013, 4; 62-76
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field-circuit modelling of an advanced welding transformer with two parallel rectifiers
Autorzy:
Sakhno, L.
Sakhno, O.
Dubitsky, S.
Powiązania:
https://bibliotekanauki.pl/articles/141600.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arc welding
double-bridge rectifier
leakage inductance
three-winding transformer
transformer equivalent circuit
Opis:
The new topology of three-winding welding transformer is proposed. Each secondary winding is connected in parallel through the separate bridge rectifier to the welding arc. The main feature of the proposed device is parallel working of two secondary windings with different rated voltage. The advantage is nonlinear transformation ratio of current that provides unprecedented power efficiency. The self- and mutual leakage inductances, which are important in power conversion, are calculated by 2D FEA model. The operational current of the device is modelled numerically via P-Spice simulator. The proposed topology is up to 30% more power effective than conventional welding transformer provided that the leakage inductances of primary and secondary windings are correctly fitted. This transformer is used for manual arc welding.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 249-257
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer aided design of snubber circuit for DC/DC converter with SiC power MOSFET devices
Autorzy:
Niewiara, Ł.
Skiwski, M.
Tarczewski, T.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/378069.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
DC\DC converter
snubber circuit
SiC MOSFET
Opis:
In this paper a computer aided design of snubber circuit for DC\DC converter is presented. Due to the presence of parasitic LC circuit in the power stage (inductance and capacitance), it is necessary to use an additional snubber circuit for voltage overshoot and oscillations reduction. A simulation model of the converter with parasitic circuit was designed. Three types of snubber circuits (C, RC, RCD) were investigated in simulation tests. Simulation model of the proposed system has been investigated in Matlab/Simulink/PLECS environment. Input signal parameters like voltage overshoot, rise time, fall time were compared for considered snubber circuits. Experimental tests were carried out for the best simulation result. It confirm the proper choice of snubber circuit.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 84; 77-83
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of fractional electrical circuit with sinusoidal input signal using Caputo and conformable derivative definitions
Autorzy:
Piotrowska, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/378130.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
fractional order system
Sinusoidal Signals
Caputo definition
conformable fractional derivative definition
fractional electrical circuit
Opis:
This paper presents the fractional electrical circuit in the transient state described by the fractional-order state-space equations. General solutions to the fractional state-space equations containing two types of definitions of fractional derivative: Caputo definition and the conformable fractional derivative definition are given the solutions in the case of: 1) control in the form of sine function at zero initial states 2) control in the form of cosine function at zero initial states 3) control in the form of the sine function with phase shift at zero initial states. The solutions are shown for capacitor voltages for fractional derivative orders of 0.7; 0.8; 1.0. The results were compared using graphs.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 97; 155-167
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ i program do wyznaczania parametrów schematu zastępczego superkondensatora
Set-up for estimation of parameters of supercapacitor equivalent circuit
Autorzy:
Przybylski, K.
Szewczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/267233.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
superkondensator
schemat zastępczy superkondensatora
supercapacitor
supercapacitor equivalent circuit
Opis:
W pracy przedstawiono prototyp urządzenia do wyznaczania parametrów schematu zastępczego superkondensatora na podstawie jego charakterystyki ładowania i rozładowania. Urządzenie składa się ze sterowanego źródła prądowego do ładowania i rozładowywania superkondensatora, przetwornika analogowo-cyfrowego do pomiaru prądu i napięcia w trakcie eksperymentu oraz mikroprocesora do sterowania pomiarem i komunikacji z komputerem na którym uruchomiony jest program sterujący. W celu sprawdzenia poprawności działania wykonanego prototypu urządzenia przeprowadzono szereg pomiarów dla wybranych dostępnych w handlu superkondensatorów. Przeprowadzone badania potwierdziły poprawność pracy zaprojektowanego układu. Oszacowane wartości rezystancji szeregowej i pojemności superkondensatorów mieszczą się w zakresach podanych przez producentów w notach katalogowych.
The paper presents the measurement set-up for estimation of supercapacitor’s equivalent circuit parameters based on its charging and discharging characteristics. The designed set-up consists of a controlled current source for charging and discharging the supercapacitor under test, an analog-to-digital converter for measuring current and voltage during the experiment and a microprocessor for controlling the measurement and for communication with the computer on which the control program is running. The program allows to set measurement parameters and presents the results of calculations of equivalent circuit parameters. The supercapacitor equivalent circuit consists of two parallel RC branches. The first one represents the series resistance and the capacity of the Helmholtz layer, while the second one relates to the diffusion of charges. In order to check the correctness of the operation of the measurement set-up, a series of measurements was carried out on commercially available supercapacitors. Their characteristics were measured for different values of charging current. Based on the obtained characteristics, the electrical parameters were determined and compared with manufacturers data. The estimated values of series resistance and capacitance are within the ranges given by datasheet.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 60; 105-108
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Open-circuit fault diagnosis in three-phase induction motor using model-based technique
Autorzy:
Aswad, Raya A. K.
Jassim, Bassim M. H.
Powiązania:
https://bibliotekanauki.pl/articles/949900.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
model-based diagnosis
number of turns
open-circuit fault
Opis:
The presence of an open-circuit fault subjects a three-phase induction motor to severely unbalanced voltages that may damage the stator windings consecutively causing total shutdown of systems. Unplanned downtime is very costly. Therefore, fault diagnosis is essential for making a predictive plan for maintenance and saving the required time and cost. This paper presents a model-based diagnosis technique for diagnosing an open-circuit fault in any phase of a three-phase induction motor. The proposed strategy requires only current signals from the faulty machine to compare them with the healthy currents from an induction motor model. Then the errors of comparison are used as an objective function for a genetic algorithm that estimates the parameters of a healthy model, which they employed to identify and localize the fault. The simulation results illustrate the behaviours of basic parameters (stator and rotor resistances, self-inductances, and mutual inductance) and the number of stator winding turn parameters with respect to the location of an open-circuit fault. The results confirm that the number of stator winding turns are the useful parameters and can be utilized as an identifier for an open-circuit fault. The originality of this work is in extracting fault diagnosis features from the variations of the number of stator winding turns.
Źródło:
Archives of Electrical Engineering; 2020, 69, 4; 815-827
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neural network based adaptive state feedback controller for inverter with voltage matching circuit
Autorzy:
Niewiara, Ł.
Tarczewski, T.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/376361.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
adaptive linear-quadratic controller
voltage matching circuit
artificial neural network
current ripple
Opis:
This paper describes a discrete adaptive state feedback controller used to load current control in terms of variable DC voltage of inverter. Controller was designed by using linear quadratic optimization method. Adaptive LQR was used because of non-stationarity of the control system caused by Voltage Matching Circuit - VMC. Gain values of the adaptive controller were approximated by using an artificial neural network. The VMC was realized as an additional buck converter integrated with the main inverter. As the load of the 2-level inverter a 3-phase symmetric RL circuit was used. Simulation tests show the behavior of the load current regulation during DC bus voltage level step changes. The dependence between current RMS value and inverter DC bus voltage level was also shown. Simulation test was made by using Matlab Simulink and PLECS software.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 80; 231-238
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental validation of equivalent circuit modelling of the piezo-stripe harvester attached to the sfsf rectangular plate
Autorzy:
Koszewnik, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/386747.pdf
Data publikacji:
2020
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
aluminium plate
piezo - harvester
energy harvesting system
modal analysis
Equivalent Circuit Model
ECM
Opis:
Plate-like structures with attached piezo-patch elements are widely used in marine, aerospace and civil infrastructure applications to power small devices with low power demand or used for monitoring of vibration structures. In order to assess the feasibility of an energy harvesting system to generate power output from a harvester, an accurate electromechanical model of the piezo-patch harvester attached to a 2D structure in modal coordinates is required. Taking into account this fact, this study is focused on the analysis of the piezoharvester orientations on the SFSF (Simply Supported-Free-Simply Supported-Free) plate undergoing forced dynamic excitation. The results obtained from the numerical analysis of a smart structure led to determining quasi-optimal piezo-harvester location on the structure, and next, to determining a multi-mode representation of the equivalent circuit model. The experimental set-up carried out on the lab stand properly verified the parameters of the ECM model. Finally, the proposed approach can be used for the structural health monitoring of vibration of some 2D mechanical structures like the front wall of a dishwasher.
Źródło:
Acta Mechanica et Automatica; 2020, 14, 1; 8-15
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Capacitive MEMS accelerometer with open-loop switched-capacitor readout circuit
Autorzy:
Szermer, M.
Amrozik, P.
Zając, P.
Maj, C.
Napieralski, A.
Powiązania:
https://bibliotekanauki.pl/articles/397869.pdf
Data publikacji:
2017
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
MEMS
ASIC
accelerometer
integrated circuit
balance disorders
akcelerometr
układy scalone
zaburzenia równowagi
Opis:
MEMS are one of the fastest developing branch in microelectronics. Many integrated sensors are widely used in smart devices i.e. smartphones, and specialized systems like medical equipment. In the paper we present the main parts of a system for measuring human movement which can be used in human balance disorder diagnosis. We describe our design of capacitive accelerometers and dedicated switched-capacitor readout circuit. Both will be manufactured as separate chips in different technological processes. The principle of operation, schematics and layouts of all parts of the system are presented. Preliminary simulations show that the proposed designs are applicable for the considered medical device.
Źródło:
International Journal of Microelectronics and Computer Science; 2017, 8, 4; 139-145
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transitional processes at switching-off unloaded power transmission lines by modern circuit-breakers and their computer simulation
Autorzy:
Lazimov, T.
Saafan, E.
Powiązania:
https://bibliotekanauki.pl/articles/410587.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
SF6 circuit-breakers
power transmission lines
computer simulation
transitional voltages
Opis:
The article presents results of transitional processes computer simulation at switching-off unloaded power transmission line of rated voltage 220 kV by auto-compression (SF6) circuit-breakers. Transitional voltages (voltage across the line terminals and recovery voltage) at switching-off were calculated and studied in the research carried out. There was also considered dependence between transitional voltages magnitudes and power transmission lines lengths. There were studied some computational peculiarities of the problem under consideration. In particular, the numbers of pi-sections provided satisfactory adequacy of lines equivalency at computer simulation for their typical lengths were determined. There were also estimated optimum simulation parameters provided stability of transitional regime parameters.
Źródło:
Present Problems of Power System Control; 2013, 4; 67-75
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhanced clock gating technique for power optimization in SRAM and sequential circuit
Autorzy:
Ashok Kumar, C.
Madhavi, B.K.
Lal Kishore, K.
Powiązania:
https://bibliotekanauki.pl/articles/2141882.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
enhanced clock gating
D-Latch gating
SRAM
sequential circuit
Area
Delay
Opis:
Low power VLSI designs are having wide variety of application usage in real-time. VLSI circuits are analyzed with various power reduction strategies. Existing approaches are used the clock frequency control, switching activity and scaling factor for power reduction. The glitching problem and clock triggering issues are higher therefore; the proposed work utilized the improved circuit of clock gating technique. In this proposed work, the enhanced clock gating with D-latch model is constructed to obtain the less power consumption. The traditional clock gating technique is improved by adding clock triggering on LATCH circuit and adding buffer circuit between the source and load circuitry to reduce the clock switching issues like gitching and clocking activity. Here the SRAM and sequential counter circuits are designed to utilize the power reduction strategy for improving the performance. This is applicable for various applications in real world and utilizing the FPGA and DSP application specific circuits. Experimental results are analyzed to obtain the power reduction result of SRAM and sequential circuit. Area, power, and delay are obtained the better results as compared with the previous work. Overall, design is performed using Xilinx 14.2 ISE suit.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2021, 15, 2; 32-38
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Qucs/QucsStudio swept parameter technique for statistical circuit simulation
Autorzy:
Brinson, M. E.
Powiązania:
https://bibliotekanauki.pl/articles/397903.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
QucsStudio
Qucs
statistical circuit simulation
swept parameter lists
Verilog-A compact semiconductor device models
statystyczna symulacja obwodu
Verilog-A
Opis:
Qucs and QucsStudio open source circuit simulators have a wealth of built in swept data features, including facilities for linear and logarithmic scans of simulation variables and for setting component values and device parameters. These simulators also allow semicolon separated lists of numerical values to be used as swept data. This little known feature provides a very flexible mechanism for generating component and device parameter statistical data. An outline of a statistical circuit simulation technique is presented in this paper. The proposed technique can be used with any general purpose circuit simulator equipped with swept data capabilities and as such is suitable for the study of device and circuit performance resulting from variations in device parameters and component values. The operation of the proposed simulation technique is illustrated with the results from an investigation of the statistical performance of a simple MOS current mirror integrated circuit cell, modeled with a speed optimized Verilog-A version of a long channel EPFL_EKV v2.6 MOS transistor model.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 3; 92-97
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Konstrukcja wyłącznika próżniowego na napięcie 7,2 kV
Construction of vacuum circuit-breaker for 7.2 kV
Autorzy:
Hejduk, A.
Powiązania:
https://bibliotekanauki.pl/articles/408656.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
wyłącznik próżniowy
napęd elektromagnesowy
magnes trwały
vacuum circuit breaker
electromagnetic drive
permanent magnet
Opis:
W artykule przedstawiono konstrukcje wyłącznika próżniowego 7,2 kV wyposażonego w niezależne napędy elektromagnesowe na każdy biegun. Ponadto omówiono wyniki prac projektowo – konstrukcyjnych oraz wyniki symulacji i badań.
The paper presents the construction of vacuum circuit-breaker 7.2 kV with electromagnetic independent drive for each pole. The drives of new construction are equipped with permanent magnets. Simulations and tests results are presented.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 2; 106-109
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of the finite element method for parameter estimation of the circuit model of a high power synchronous generator
Autorzy:
Berhausen, S.
Paszek, S.
Powiązania:
https://bibliotekanauki.pl/articles/200790.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
synchronous generator model
finite element method
field-circuit model measurement verification
circuit model parameter estimation
model synchronicznego generatora
metoda elementów skończonych
weryfikacja modelu pomiaru pola obwodu
estymacja parametrów modelu obwodu
Opis:
The paper presents the two-dimensional, field-circuit model of a high power synchronous generator verified by measurements. The model enables determining the waveforms of electromagnetic quantities in steady and transient states. Verification of the model was based on comparison of the measured and calculated waveforms after a disturbance in the voltage regulation system of a TWW-200-2 generator operating in Połaniec Power Plant. There are also presented the field methods for determining electromagnetic parameters (synchronous reactances and time constants) when using the distributions of static and quasi-static, magnetic and electromagnetic fields calculated by the finite element method (FEM). The set of these parameters was used as the starting parameters of the optimization algorithm for estimation of electromagnetic parameters of the synchronous generator circuit model. The dynamic waveforms under the generator load conditions calculated by the finite element method are the basis of parameter estimation. The parameter estimation of the generator model was performed with the use of the least squares method.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 3; 575-582
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Based on neural network adaptive linear quadratic regulator for inverter with voltage matching circuit
Autorzy:
Niewiara, Ł.
Tarczewski, T.
Grzesiak, L.M.
Powiązania:
https://bibliotekanauki.pl/articles/97686.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
adaptive linear-quadratic regulator
voltage matching circuit
artificial neural network
current ripple
Opis:
This paper describes a discrete adaptive linear quadratic regulator used to load current control in terms of variable DC voltage of inverter. Controller was designed by using linear quadratic optimization method. Adaptive LQR was used because of non-stationarity of the control system caused by Voltage Matching Circuit - VMC. Gain values of the adaptive controller were approximated by using an artificial neural network. The VMC was realized as an additional buck converter integrated with the main inverter. As the load of the 2-level inverter a 3-phase symmetric RL circuit was used. Simulation tests show the behavior of the load current regulation during DC bus voltage level step changes. The dependence between current RMS value and inverter DC bus voltage level was also shown. There were also made a comparison of the traditional 2-level inverter structure with the modified structure uses VMC. Simulation test was made by using Matlab Simulink and PLECS software.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 434-443
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja prądu w obwodzie elektrycznym cewkowej wyrzutni magnetycznej
Current control in the electric circuit of the coil magnetic launcher
Autorzy:
Gosiewski, Z.
Kondratiuk, M.
Kłoskowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/387382.pdf
Data publikacji:
2009
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
regulacja
prąd
wyrzutnia magnetyczna
obwód
magnetic launcher
circuit
Opis:
W niniejszym artykule przedstawiono koncepcję sterowania prądem w obwodzie elektrycznym cewkowej wyrzutni magnetycznej. Zaproponowano sposób realizacji układu regulacyjnego oraz zamodelowano elektroniczne komponenty obwodu. Przeprowadzono symulacje obiektu wraz z regulatorem impulsowym dzięki któremu stabilizowano wartości prądu w obwodzie cewki przy rozładowaniu kondensatora. W czasie symulacji dobrano odpowiednią częstotliwość pracy kontrolera. Badania przeprowadzono dla różnych wartości indukcyjności zwojnicy, co miało na celu określenie poprawności koncepcji sterowania dla zmienionych parametrów obiektu. Przeprowadzono analizę uzyskanych wyników oraz przedstawiono możliwości realizacji fizycznego układu. Niniejsze badania stanowią fazę wstępną przed budową eksperymentalnego modelu cewkowej wyrzutni elektromagnetycznej o stabilizowanym przyspieszeniu rdzenia.
In this paper the conception of current control in the electric circuit of the coil magnetic launcher is presented. The implementation manner of the regulation system was proposed and electronic component of the electric circuit were modelled. The system of the object and the impulse regulator was simulated. When the coil was energised by discharging capacitor, the controller stabilised circuit current value. The appropriate frequency of the regulator work was obtained by the means of simulation. Research was conducted for different values of the coil inductance. Thus we checked control system correctness for the variable model parameters. The analysis of the simulation was conducted and its results were depicted. Described investigations state preliminary steps of designing and building of the coil magnetic launcher experimental model with stabilised armature acceleration.
Źródło:
Acta Mechanica et Automatica; 2009, 3, 1; 40-44
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new multistable jerk chaotic system, its bifurcation analysis, backstepping control-based synchronization design and circuit simulation
Autorzy:
Vaidyanathan, Sundarapandian
Benkouider, Khaled
Sambas, Aceng
Powiązania:
https://bibliotekanauki.pl/articles/2106506.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chaos
jerk systems
bifurcation
multistability
attractors
backstepping control
circuit design
Opis:
In this work, we present results for a new dissipative jerk chaotic system with three quadratic terms in its dynamics.We describe the bifurcation analysis for the new jerk system and also show that the proposed system exhibits multi-stability. Next, we describe a backstepping control-based synchronization design for a pair of new jerk chaotic systems. MATLAB simulations are put forth to exhibit the various findings in this work. Furthermore, we exhibit a circuit simulation for the new jerk system using MultiSim.
Źródło:
Archives of Control Sciences; 2022, 32, 1; 123--152
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
"Układ zamknięty" jako filmowy performatyw
"The Closed Circuit" as a film performative
Autorzy:
Przepiórka, Michał
Powiązania:
https://bibliotekanauki.pl/articles/517823.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Wrocławski. Wydział Nauk Historycznych i Pedagogicznych. Katedra Etnologii i Antropologii Kulturowej
Tematy:
performatyka
posthumanizm
analiza recepcji
wspólnota interpretacyjna
"Układ zamknięty"
performance theory
posthumanism
analysis of reception
interpretive community
"The Closed Circuit"
Opis:
Artykuł ma na celu ukazanie filmu jako „przedmiotu” działającego – wywołującego spory, ustanawiającego nowe przestrzenie konfliktu oraz ujawniającego wiedzę wspólnot interpretacyjnych. W tym celu przywołuję teorię posthumanizmu, będącego jednym z przejawów zwrotu performatywnego w humanistyce. Według niej, społecznych zmian nie da się interpretować bez włączania w proces refleksji przedmiotów nieożywionych, które wyznaczają ramę ludzkiego postępowania i myślenia. Najważniejszą częścią artykułu jest analiza recepcji filmu Układ zamknięty Ryszarda Bugajskiego, na przykładzie której tropię, w jaki sposób film oddziałuje na odbiorców, ustanawia wspólnoty interpretacyjne oraz staje się aktywnym czynnikiem więziotwórczym.
This article shows film as a performing “object”, which induces controversies, establishes new fields of conflicts and discloses knowledge of interpretive communities. For this reason I use theory of posthumanism, what is a part of performative turn in the humanities. The main part of this article is an analysis of The Closed Circuit’s reception. It is an example of how film influences on viewers, establishes interpretative communities and becomes an active agent.
Źródło:
Tematy z Szewskiej; 2014, Performatywność 1(11)/2014; 46-68
1898-3901
Pojawia się w:
Tematy z Szewskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new three-dimensional chaotic system with a hidden attractor, circuit design and application in wireless mobile robot
Autorzy:
Vaidyanathan, S.
Sambas, A.
Mamat, M.
Sanjaya, M.
Powiązania:
https://bibliotekanauki.pl/articles/229628.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chaos
chaotic systems
hidden attractors
circuit simulation
Opis:
This research work proposes a new three-dimensional chaotic system with a hidden attractor. The proposed chaotic system consists of only two quadratic nonlinearities and the system possesses no critical points. The phase portraits and basic qualitative properties of the new chaotic system such as Lyapunov exponents and Lyapunov dimension have been described in detail. Finally, we give some engineering applications of the new chaotic system like circuit simulation and control of wireless mobile robot.
Źródło:
Archives of Control Sciences; 2017, 27, 4; 541-554
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low voltage modular circuit breakers: FEM employment for modelling of arc chambers
Autorzy:
Kolimas, Ł.
Łapczyński, S.
Szulborski, M.
Świetlik, M.
Powiązania:
https://bibliotekanauki.pl/articles/201038.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
miniature circuit breaker
finite element method (FEM)
computational fluid dynamics (CFD)
arc chambers
Opis:
FEM (finite element method) is an essential and powerful numerical method that can explicitly optimize the design process of electrical devices. In this paper, the employment of FEM tools such as SolidWorks, COMSOL and ANSYS is proposed in order to aid electrical apparatuses engineering and modeling – those are arc chambers of modular circuit breakers. Procured models of arc chambers have been undergoing simulations concerning heating, electric potential distribution, electric charge velocity and traverse paths. The data acquired has been juxta-positioned against experimental data procured in the Short-Circuit Laboratory, Warsaw University of Technology. The reflection of the theoretical approach was clearly noted in the experimental results. Mutual areas of the modeled element expressed the same physical properties and robustness errors when tested under specific conditions – faithfully reflecting those which were experimented with. Moreover, the physical phenomena essential for electrical engineering could be determined already at the model stage. This procedure proved highly valuable during designing/engineering work in terms of material economy.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 1; 61-70
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Researches and tests of high-speed circuit breakers for rolling stock and substations in 3 kV DC traction power system
Badania pojazdowych i podstacyjnych wyłączników szybkich w systemie zasilania trakcji 3 kV DC
Autorzy:
Rojek, A.
Sidorowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/952291.pdf
Data publikacji:
2013
Wydawca:
Instytut Kolejnictwa
Tematy:
wyłącznik szybki
zwarcia
prąd krytyczny
koordynacja zabezpieczeń
high-speed circuit breaker
short circuit
critical currents
coordination of protection
Opis:
Before placing in service in the railway electrical traction high-speed circuit-breakers shall be the subject of conformity tests with standards. The high-speed circuit breakers are an essential safeguard against the flow of an excessive current in the circuit overhead line and vehicles being powered by it. That is the reason why the circuit breakers must be equipped with systems which allow extinguish the high-energy arc. Additionally, the short circuit currents must be switched off as soon as possible to minimize the risk of damage, protected by circuit breakers, elements of an electric traction power supply system. The main document identifying requirements and a scope of the high-speed DC circuit breakers research for traction substation and sectioning cabins is the PN-EN 50123-2 standard. In the case of the on- board high-speed DC circuit breakers, requirements and scope of the research regulates the PN-EN 60077-3 standard. Although, two standards - PN-EN 50123 and PN-EN 60077-3 - apply to the same type of electric gear, the symbols and volume and parameter indexes used therein are different, what causes some inconvenience in analysis and results comparison, especially in terms of circuit breaker cooperation (f.e. in ensuring the coordination of short circuit protection in the traction vehicle - traction substation relation). Besides above standards, the requirements for high-speed DC circuit breakers are contained in PN-EN 50388 standard and technical specification for interoperability of the subsystem “Energy” (TSI “Energy”). For most of the test points and high speed D.C. circuit breaker checks, requirements that are contained in standards, testing and results are not problematic. However, part of the research and their result may be the basis of a discussion about real properties and parameters of circuit breakers. These tests and checks are contact life research, switching capacity check, designation and critical currents switching off and coordination of short circuit protection in the traction vehicle - traction substation relation. The data analysis presented by the producers of circuit breakers show that none of them classifies their products as one of the type: H, V or S, that are defined by PN-EN 50123 standard. Based on many measurements performed by Instytut Kolejnictwa it is possible to determine the type of high-speed D.C. circuit breakers designed to 3 kV D.C. system, produced by the leading European companies. The example of the current limiting very high-speed circuit breaker type V that is produced in Poland can be taken only one of a type DCN. The current limiting high-speed circuit breaker type H is a one of a series BWS, while circuit breakers UR40 is classified to the semi-high-speed circuit breaker type S. The next “imperfection” of the standards containing the requirements for high-speed D.C. circuit breakers is a guideline for short circuit. In such a short circuit should be only inductance and resistance. Whereas in the real conditions in short circuits, where high-speed circuit breakers are working, there are capacities, for example as filters in traction vehicles. Analyzing the short circuit current flow it can be stated that switching on of resonance filter caused extra switching off time about 10%. As a result of later release and oscillating changes of short circuit current, the value of maximum limiting short circuit current increases about 15%. The critical currents switching off are bonded with relatively long burning arc on the contacts of circuit breaker. The burning time of an arc while small values of currents switching off is form over a dozen to ten times longer, than short circuit currents. By this time, which can be up to few or even several seconds, the circuit breaker contacts are exposed to arc, arcing horns and arc chamber. It causes significant arcing erosion of these elements. The standards do not define at what time critical currents should be switched off and do not specify which critical currents value should be taken as a result of tests. To achieve selectivity of short circuit and overload currents switching offs forming in rolling stock is possible while on-board circuit breaker switches off the current before the circuit breaker for use in substations and sectioning cabins will get tripped. It will happen only when on-board circuit breaker limits the current to a value lower than the tripping level of the circuit breaker for use in the fixed installations. It will happen when steepness of short circuit grow is small enough that on-board circuit breaker starts to limit the current before it reaches the tripping level of high-speed circuit breaker for use in substation. The limit value di/dt, at which short circuit current will be switched off only be the on-board circuit breaker depends on independent opening time of on-board circuit breaker, its limiting current capacity and the difference between the value of setting of on-board circuit breaker for use in fixed installations. The results of the simulation, analysis and tests show, that it is not, at the moment, possible to obtain selective short circuit switching offs in rolling stock. At the European market of circuit breakers the greatest range of selectivity show vacuum circuit breakers DCN-L and DCU using in rolling stock.
Przed dopuszczeniem do eksploatacji w kolejowej trakcji elektrycznej wyłączniki szybkie prądu stałego muszą być poddane badaniom na zgodność z normami. Wyłączniki szybkie są podstawowym zabezpieczeniem przed przepływem nadmiernych wartości prądu w obwodach sieci trakcyjnej oraz zasilanych z niej pojazdów. Dlatego muszą być wyposażone w układy umożliwiające zgaszenie łuku o dużej energii. Dodatkowo prądy zwarciowe muszą być wyłączone w jak najkrótszym czasie, aby zminimalizować ryzyko uszkodzenia chronionych przez wyłączniki elementów systemu zasilania trakcji elektrycznej. Podstawowym dokumentem, określającym wymagania i zakres badań wyłączników szybkich prądu stałego przeznaczonych do podstacji trakcyjnych i kabin sekcyjnych, jest norma PN EN 50123-2. W przypadku wyłączników szybkich przeznaczonych do eksploatacji w pojazdach trakcyjnych wymagania i zakres badań reguluje norma PN-EN 60077-3. Pomimo, że obydwie normy dotyczą tego samego typu aparatów elektrycznych, stosowane w nich oznaczenia i indeksy wielkości i parametrów są inne, co powoduje pewne niedogodności w analizach i porównywaniu wyników, w szczególności w aspekcie współpracy wyłączników, np. przy zapewnianiu koordynacji zabezpieczeń zwarciowych w układzie pojazd trakcyjny – podstacja trakcyjna. Oprócz wymienionych norm, wymagania dla wyłączników szybkich są zawarte w normie PN-EN 50388 oraz specyfikacji technicznej interoperacyjności podsystemu „Energia”. Dla większości punktów zakresu badań i sprawdzeń wyłączników szybkich, wymagania zawarte w normach oraz przeprowadzenie i wyniki badań nie są problematyczne. Jednak część badań i ich wynik mogą być podstawą dyskusji dotyczących rzeczywistych właściwości i parametrów wyłączników. Do tych badań i sprawdzeń należą badanie trwałości łączeniowej, sprawdzenie zdolności łączeniowej prądów zwarciowych, wyznaczenie i wyłączenie prądów krytycznych i koordynacja zabezpieczeń zwarciowych w układzie pojazd trakcyjny – podstacja trakcyjna. Wyniki analizy danych przedstawianych przez producentów wyłączników pokazują, że żaden z nich nie klasyfikuje produkowanych wyłączników jako jednego z typów: H, V lub S, zdefiniowanych w normie PN-EN 50123. Na podstawie pomiarów prowadzonych przez Instytut Kolejnictwa jest możliwe określenie typu wyłączników szybkich prądu stałego przeznaczonych do systemu 3 kV DC, produkowanych przez czołowe firmy europejskie. Za wyłącznik typu V można uznać jedynie wyłącznik typu DCN. Wyłącznikiem typu H jest wyłącznik serii BWS, natomiast parametry wyłączników typu UR40. Kolejną „niedoskonałością” norm zawierających wymagania dla wyłączników szybkich prądu stałego, jest wytyczna dotycząca obwodu zwarciowego. W obwodzie tym powinny występować jedynie indukcyjność i rezystancja. Natomiast w warunkach rzeczywistych w obwodach zwarciowych, w których pracują wyłączniki szybkie występują pojemności, np. w postaci urządzeń wygładzających w podstacjach trakcyjnych lub filtrów wejściowych w pojazdach trakcyjnych. Analizując wyniki badań zwarciowych można stwierdzić, że załączenie urządzenia wygładzającego spowoduje wydłużenie czasu wyłączania o około 10%. W wyniku późniejszego wyzwolenia oraz oscylacyjnych zmian prądu zwarciowego, wartość maksymalnego ograniczonego prądu zwarcia zwiększa się o około 15%. Wyłączanie prądów krytycznych wiąże się ze stosunkowo długotrwałym paleniem łuku na stykach wyłącznika. Czas palenia się łuku przy wyłączaniu prądów o małej wartości jest od kilkunastu do kilkudziesięciu razy dłuższy, niż w przypadku wyłączania prądów zwarciowych. Przez ten czas, który może dochodzić do kilku, a nawet kilkunastu sekund, na działanie łuku są narażone styki wyłącznika, rożki łukowe i komora łukowa. Powoduje to znaczną erozję łukową tych elementów. Normy nie definiują w jakim czasie prądy krytyczne powinny być wyłączane oraz nie określają jaką wartość prądów krytycznych należy przyjmować jako wynik badań. Uzyskanie selektywności wyłączeń prądów zwarciowych i przetężeniowych powstających w taborze jest możliwe wówczas, gdy wyłącznik taborowy wyłączy prąd zanim zostanie wyzwolony wyłącznik w podstacji trakcyjnej lub w kabinie sekcyjnej. Nastąpi to tylko w przypadku, gdy wyłącznik taborowy ograniczy prąd do wartości niższej od poziomu wyzwolenia wyłącznika podstacyjnego. Wystąpi to w przypadku, gdy stromość wzrostu prądu zwarciowego będzie na tyle mała, że wyłącznik taborowy zacznie ograniczać prąd zanim osiągnie on poziom wyzwalania wyłącznika szybkiego w podstacji. Wartość graniczna di/dt, przy której prąd zwarciowy będzie wyłączany tylko przez wyłącznik taborowy, zależy od czasu własnego otwarcia wyłącznika w pojeździe, jego zdolności ograniczania prądu i różnicy pomiędzy wartościami nastaw wyłączników taborowego i podstacyjnego. Wyniki symulacji, analiz i badań pokazują, że obecnie nie jest możliwe uzyskanie każdorazowo selektywności wyłączeń prądów zwarciowych w taborze. Największy zakres selektywności można uzyskać w przypadku zastosowania w taborze próżniowych wyłączników serii DCN-L i DCU.
Źródło:
Problemy Kolejnictwa; 2013, 159; 7-30
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of single and multiple IGBTs open-circuit faults in a field-oriented controlled induction motor drive
Autorzy:
Sobański, P.
Orłowska-Kowalska, T.
Powiązania:
https://bibliotekanauki.pl/articles/140648.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
field-oriented control
condition monitoring
open-circuit
fault
fault diagnosis
Opis:
In this paper a transistor open-circuit fault diagnosis method in a rotor field oriented controlled induction motor drive, fed by a two-level voltage inverter has been proposed. The diagnostic procedure ensures detection and localization of single or multiple power switch failures in time shorter than one period of a stator current fundamental harmonic, without regard to a drive operation point. A new simple scheme of the diagnostic system is proposed. In order to validate the proposed transistor fault diagnostic method, a detailed simulation as well as experimental tests of the field-oriented control drive system were carried out and some of them are shown in this paper.
Źródło:
Archives of Electrical Engineering; 2017, 66, 1; 89-104
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An accurate prediction of high-frequency circuit behaviour
Autorzy:
Yoshitomi, S.
Kimijima, H.
Kojima, K.
Kokatsu, H.
Powiązania:
https://bibliotekanauki.pl/articles/308807.pdf
Data publikacji:
2005
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
electro-magnetic simulation
SPICE
circuit test structure
RF CMOS
EKV2.6-MOS model
spiral inductor
CMOS VCO
Opis:
An accurate way to predict the behaviour of an RF analogue circuit is presented. A lot of effort is required to eliminate the inaccuracies that may generate the deviation between simulation and measurement. Efficient use of computer-aided design and incorporation of as many physical effects as possible overcomes this problem. Improvement of transistor modelling is essential, but there are many other unsolved problems affecting the accuracy of RF analogue circuit modelling. In this paper, the way of selection of accurate transistor model and the extraction of parasitic elements from the physical layout, as well as implementation to the circuit simulation will be presented using two CMOS circuit examples: an amplifier and a voltage controlled oscillator (VCO). New simulation technique, electro-magnetic (EM)-co-simulation is introduced.
Źródło:
Journal of Telecommunications and Information Technology; 2005, 1; 47-62
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The equivalent circuit of specially designed induction motor for a main drive system of polymerization reactor
Autorzy:
Rusek, A.
Powiązania:
https://bibliotekanauki.pl/articles/1372702.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
reaktor polimeryzacji
układ napędowy
schemat zastępczy
induction motor
polymerization reactor
drive system
equivalent circuit
Opis:
In the paper a construction of specially designed induction motor for a main drive system of polymerization reactor taking into account the power loss in large-size slide bearing made of sintered carbides is described. The constructional details of motor-bearing set allowing for vertical operation of motor are also given (1), (2). The analysis of power distribution taking into account a slide friction loss in bearing is presented. Resistances of equivalent circuit secondary part as additional vertical branches are determined. The equations describing specially designed induction motor for drive system of polymerization reactor are given. In the equations the loss in large-size slide bearing is taken into account. The equations allow determining static characteristics of the motor. Moreover, in equivalent circuit the phenomenon of agglutination of rotor with stator is taken into account as a result of polymerization phases in reactor chamber where the motor is placed.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2011, 4, 92; 103-108
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polowo-obwodowy model osiowosymetrycznego aktuatora liniowego
The field-circuit model of axis-symmetrical linear actuator
Autorzy:
Mikołajewicz, J.
Wojciechowski, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/1367685.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Model polowo-obwodowy
aktuator liniowy
analiza numeryczna
Field-circuit model
linear actuator
numerical analysis
Opis:
In the paper a field-circuit model of axis-symmetrical linear actuator has been presented. An actuator with conical armature has been considered and investigated. The integral parameters of the model, such as the inductance and the force have been determined on the basis of 2D electromagnetic field distributions, which have been obtained for the field model. Then, the calculated parameters have been implemented to the circuit model, ie. the model of the system comprising the coupled equations of the electrical circuit and the mechanical equilibrium equation of the considered actuator. In the considerations, the eddy current effect has not been taken account. The selected results of simulations have been presented.
W artykule przedstawiono polowy-obwodowy model osiowosymetrycznego aktuatora liniowego. Rozpatrywano aktuator nurnikowy z nurem stożkowym. Parametry całkowe modelu, takie jak indukcyjność oraz siła, zostały wyznaczone na podstawie rozkładu dwuwymiarowego pola magnetycznego. Obliczone parametry skupione następnie zaimplementowano w modelu obwodowym przetwornika, tzn. modelu obejmującym układ sprzężonych równań obwodu elektrycznego oraz równania dynamiki. W rozważaniach pominięto tłumiący charakter prądów wirowych. Przedstawiono wybrane wyniki badań symulacyjnych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 173-177
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new 4-D hyperchaotic system with no equilibrium, its multistability, offset boosting and circuit simulation
Autorzy:
Vaidyanathan, Sundarapandian
Moroz, Irene M.
Sambas, Aceng
Powiązania:
https://bibliotekanauki.pl/articles/229944.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chaos
chaotic systems
hidden attractors
sliding mode control
circuit design
synchronization
Opis:
A new 4-D dynamical system with hyperchaos is reported in this work. It is shown that the proposed nonlinear dynamical system with hyperchaos has no equilibrium point. Hence, the new dynamical system exhibits hidden hyperchaotic attractor. An in-depth dynamic analysis of the new hyperchaotic system is carried out with bifurcation transition diagrams, multistability analysis, period-doubling bubbles and offset boosting analysis. Using Integral Sliding Mode Control (ISMC), global hyperchaos synchronization results of the new hyperchaotic system are described in detail. Furthermore, an electronic circuit realization of the new hyperchaotic system has been simulated in MultiSim software version 13.0 and the results of which are in good agreement with the numerical simulations using MATLAB.
Źródło:
Archives of Control Sciences; 2020, 30, 3; 575-597
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of an anti-parallel memristor circuit
Analiza przeciwrównoległego obwodu memrystorowego
Autorzy:
Mladenov, V.
Kirilov, S.
Powiązania:
https://bibliotekanauki.pl/articles/408335.pdf
Data publikacji:
2018
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
memristor
anti-parallel memristor circuit
finite differences method
equivalent resistance
memrystor
przeciwrównoległy obwód memrystorowy
metoda różnic skończonych
rezystancja równoważna
Opis:
The basic purpose of the present paper is to propose an extended investigation and computer analysis of an anti-parallel memristor circuit with two equivalent memristor elements with different initial values of the state variables using a modified Boundary Condition Memristor (BCM) Model and the finite differences method. The memristor circuit is investigated for sinusoidal supply current at different magnitudes – for soft-switching and hardswitching modes, respectively. The influence of the initial values of the state variables on the circuit’s behaviour is presented as well. The equivalent i-v and memristance-flux and the other important relationshipsof the memristor circuit are also analyzed.
Podstawowym celem niniejszego artykułu jest zaproponowanie rozszerzonego badania i komputerowej analizy przeciwrównoległego układu memrystorowego z dwoma równoważnymi elementami memrystorowymi o różnych wartościach początkowych zmiennych stanu z wykorzystaniem zmodyfikowanego modelu Boundary Condition Memristor (BCM) i metody różnic skończonych. Obwód memrystorowy jest badany dla sinusoidalnego prądu zasilania o różnych wielkościach – odpowiednio dla trybów miękkiego przełączania i twardego przełączania. Przedstawiono również wpływ wartości początkowych zmiennych stanu na zachowanie obwodu. Analizowane są również równoważne charakterystyki prądowo-napięciowe zależność między memrystancją i strumieniem magnetycznym oraz inne ważne cechy obwodu memrystora.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2018, 8, 2; 9-14
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indirect test circuit for testing high voltage fuses in overload conditions
Układ do zastępczych badań bezpieczników wysokiego napięcia na prądy przeciążeniowe
Autorzy:
Kuraszkiewicz, J.
Bandel, J.
Hejduk, A.
Krasuski, K.
Dzierżyński, A.
Staniszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/158595.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
bezpieczniki wysokiego napięcia
próba przeciążeniowa
cykl łączeniowy nr 3
metoda dwuźródłowa
przełącznik ultraszybki
high voltage fuse
fast operating switch
current circuit
voltage circuit
Opis:
Próba określenia zdolności wyłączania prądów przeciążeniowych bezpieczników na wysokie napięcie wykonywana w układzie bezpośrednim związana jest z koniecznością długotrwałego obciążenia bezpiecznika dużym prądem w obwodzie wysokiego napięcia. Zamiast układu do badań bezpośrednich można korzystać z układu zastępczego, dwuźródłowego, w którym nagrzewanie bezpiecznika odbywa się w obwodzie niskonapięciowym, a dopalanie w obwodzie wysokiego napięcia. Dla równoważności obu prób konieczne jest dokonanie przełączenia z jednego układu na drugi w możliwie najkrótszym czasie. W artykule opisano również ultra szybki przełącznik, który pozwala na takie przełączenie i pokazano przykładowy przebieg próby.
During direct tests of high voltage fuses in overload conditions, the tested fuse has to carry the rated overload current at the rated voltage for a long enough time to interrupt the overcurrent. These types of tests cannot be done in short circuit laboratories. A short circuit generator cannot be excited for the length of time needed to complete the test. Therefore the indirect test method is often applied. It uses separate current and voltage circuits in sequence: first the fuse is supplied from a low voltage current circuit to conduct a current of the recommended intensity and, at the moment of the current interruption, the fuse is disconnected from the low voltage circuit and switched to a high voltage circuit. To ensure the equivalence of the direct and indirect tests the switching time from the current to the voltage circuit should be as short as possible. This paper describes a fast operating switch for use in such tests.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 274; 83-87
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko dydaktyczne do badania nowoczesnych niskonapięciowych wyłączników dużej mocy
The labolatory stand for investigation of modern LV circuit-breakers
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/268032.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyłączniki dużej mocy
interfejsy komunikacyjne
wyzwalacze elektroniczne
LV circuit breakers
communication
electronic trip units
Opis:
Nowoczesne systemy rozdziału energii stawiają przed wyłącznikami mocy coraz większe wymagania, przekraczające realizacje funkcji ochronnych i zabezpieczeniowych. Z tego względu nowoczesna aparatura łączeniowa niskiego napięcia powinna sprostać wymaganiom stawianym przez nowoczesne systemy sterowania w zakresie: komunikacji, wsparcia programowalnego, diagnostyki i możliwości szybkiej archiwizacji zdarzeń. Sytuacja taka powoduje konieczność wprowadzenia tej tematyki do programu studiów. W pracy przedstawiono opis stanowiska laboratoryjnego do badania nowoczesnych wyłączników niskiego napięcia oraz przyjętą metodę nauczania.
Modern power distribution systems demand from circuit breaker more and more complex functions going simple protection. Therefore, modern LV switchgear must comply with new expectation defined by control systems concerning communication, ability of programming, monitoring, recording of events, etc. To instruct student on these special demands and means to deal with them a special laboratory stand has been prepared.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 25; 87-90
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of circuit and operation for DC–DC converter based on silicon carbide
Autorzy:
Niewiara, Ł. J.
Tarczewski, T.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/97287.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
DC\DC converter
SiC MOSFETS
high switching frequency
DC–DC converter design
snubber circuit
Opis:
In this paper operating analysis of DC–DC converter is presented. Silicon Carbide based DC–DC converter is investigated. SiC power switches (i.e. MOSFETs and diodes) were used. Synchronous buck topology is applied for converter structure. The DC–DC converter mathematical model is also presented. The parameters of LC circuit were calculated using shown equations. Working conditions determine the values of output LC circuit (inductance and capacitance). Real power semiconductors are equipped in output and input capacitances. This feature may influence the generated input signal. Parasitic capacitances and inductances of the paths causes oscillations and voltage overshoots of the input PWM signal. To avoid such phenomenon, it is necessary to use a snubber circuit. This issue is also presented. The analysis of working conditions is presented for different switching frequencies. The size of passive components (LC) is compared for different operating points. Experimental tests results were presented. Waveforms of voltage and current signals were also shown.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 268-279
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel method of handling tolerances for analog circuit fault diagnosis based on normal quotient distribution
Autorzy:
Ao, Y.
Shi, Y.
Zhang, W.
Li, X.
Powiązania:
https://bibliotekanauki.pl/articles/221119.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-fault diagnosis
analog circuit
Normal Quotient Distribution
Slope Fault Model
Opis:
While the Slope Fault Model method can solve the soft-fault diagnosis problem in linear analog circuit effectively, the challenging tolerance problem is still unsolved. In this paper, a proposed Normal Quotient Distribution approach was combined with the Slope Fault Model to handle the tolerances problem in soft-fault diagnosis for analog circuit. Firstly, the principle of the Slope Fault Model is presented, and the huge computation of traditional Slope Fault Characteristic set was reduced greatly by the elimination of superfluous features. Several typical tolerance handling methods on the ground of the Slope Fault Model were compared. Then, the approximating distribution function of the Slope Fault Characteristic was deduced and sufficient conditions were given to improve the approximation accuracy. The monotonous and continuous mapping between Normal Quotient Distribution and standard normal distribution was proved. Thus the estimation formulas about the ranges of the Slope Fault Characteristic were deduced. After that, a new test-nodes selection algorithm based on the reduced Slope Fault Characteristic ranges set was designed. Finally, two numerical experiments were done to illustrate the proposed approach and demonstrate its effectiveness.
Źródło:
Metrology and Measurement Systems; 2012, 19, 4; 817-830
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new multi-stable chaotic hyperjerk system, its special features, circuit realization, control and synchronization
Autorzy:
Pham, Viet-Thanh
Vaidyanathan, Sundarapandian
Volos, Christos
Jafari, Sajad
Kapitaniak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/229416.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chaos
hyperjerk system
multi-stable
control
synchronization
circuit design
Opis:
Researchers have paid significant attention on hyperjerk systems, especial hyperjerk ones with chaos. A new hyperjerk system with seven terms and two parameters is analyzed. Chaotic attractors as well as coexisting attractors are displayed by the hyperjerk system. Thus it is a new multi-stable chaotic hyperjerk system. Further properties of the proposed hyperjerk system such as circuit design and backstepping-based control and synchronization are reported.
Źródło:
Archives of Control Sciences; 2020, 30, 1; 23-45
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the efficiency of metal recovery from printed circuit boards using gravity processes
Autorzy:
Franke, Dawid M.
Suponik, Tomasz
Nuckowski, Paweł M.
Dubaj, Justyna
Powiązania:
https://bibliotekanauki.pl/articles/1445935.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
metals recovery
printed circuit board
gravity separation
ICP-AES
SEM-EDS
Opis:
This paper evaluates the efficiency of metal recovery from printed circuit boards (PCBs) using two gravity separation devices: a shaking table and a cyclofluid separator. The test results were compared with the results obtained from previous research, where an electrostatic separation process was used for an identically prepared feed. The feed for the separators consisted of PCBs shredded in a knife mill at cryogenic temperatures. The separation efficiency and purity of the products were evaluated based on microscopic analysis, ICP-AES, SEM-EDS, XRD, and specific density. The yield of concentrates (valuable metals) obtained from the shaking table and the cyclofluid separator amounted to 25.7% and 18.9%, respectively. However, the concentrate obtained from the cyclofluid separator was characterised by much higher purity, amounting to ~88% of valuable metals, compared to ~72% for the shaking table. In both cases, middlings formed a significant share, their yield amounting to ~25%, with the share of valuable metals of ~15%. The yield of waste obtained from the shaking table and the cyclofluid separator were 42.6% and 52.5%, respectively. In both cases, as a result of the applied process, the waste was divided into two homogeneous groups differing in grain size and shape. The recovery of metals through gravity separation is possible, in particular, by using a shaking table. These processes can also be applied to separate waste (plastics) into two groups to be selectively processed to produce new materials in line with a circular economy.
Źródło:
Physicochemical Problems of Mineral Processing; 2021, 57, 4; 63-77
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applicability of Park transformation for the analysis of transient performance during subsynchronous resonances
Autorzy:
Kreischer, Ch.
Kulig, S.
Göbel, C.
Powiązania:
https://bibliotekanauki.pl/articles/140498.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
subsynchronous resonances
parameter identification
equivalent circuit
standstill frequency response test
three phase short circuit test
evolutionary strategy
Opis:
Long transmission lines have to be compensated to enhance the transport of active power. But a wrong design of the compensation may lead to subsynchronous resonances (SSR). For studies often park equivalent circuits are used. The parameters of the models are often determined analytically or by a three-phase short-circuit test. Models with this parameters give good results for frequencies of 50 Hz and 100 Hz resp. 60 Hz and 120 Hz. But SSR occurs at lower frequencies what arises the question of the reliability of the used models. Therefore in this publication a novel method for the determination of Park equivalent circuit parameters is presented. Herein the parameters are determined form time functions of the currents and the electromagnetic moment of the machine calculated by transient finite-element simulations. This parameters are used for network simulations and compared with the finite-element calculations. Compared to the parameters derived by a three-phase short-circuit a significant better accuracy of simulation results can be achieved by the presented method.
Źródło:
Archives of Electrical Engineering; 2013, 62, 3; 401-415
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring wizyjny na przejazdach kolejowych z zastosowaniem sieci informatycznych
Closed Circuit Television at railway crossings using a computer network
Autorzy:
Siergiejczyk, M.
Rosiński, A.
Powiązania:
https://bibliotekanauki.pl/articles/311235.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
monitoring wizyjny
sieci informatyczne
telematyka transportu
closed circuit television
computer network
transport telematics
Opis:
W artykule przedstawiono zagadnienia związane z systemami monitoringu wizyjnego zastosowanymi jako systemy telematyki transportu zwiększające poziom bezpieczeństwa na przejazdach kolejowych. Podano ich strukturę ze szczególnym uwzględnieniem zastosowania sieci informatycznych do przesyłu informacji. Zwrócono szczególną uwagę na kwestie związane z eksploatacją tych systemów.
This paper presents the issues related to Closed Circuit Television systems applied as transport telematics systems improve safety at railroad crossings. There is presented their structure with particular emphasis on the use of computer networks to transmit information. Special attention was paid to issues related to the exploitation of these systems.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2013, 14, 3; 1451-1456
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanów zwarciowych w przekształtnikach dużej mocy
Analysis of short circuit conditions in high power devices
Autorzy:
Zymmer, K.
Maścibrodzki, I.
Powiązania:
https://bibliotekanauki.pl/articles/159857.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
przekształtniki dużej mocy
stany zwarciowe
przyrządy energoelektroniczne
High Power converters
short circuit conditions
semiconductor power devices
Opis:
W artykule przedstawiono metodę określania zagrożeń uszkodzeniem przyrządów energoelektronicznych oraz eksplozją tych elementów w warunkach zwarć zewnętrznych i wewnętrznych w przekształtnikach dużej mocy. Metoda oparta jest na analizie porównawczej prądów przeciążeniowych deklarowanych przez wytwórców przyrządów półprzewodnikowych jako dopuszczalne z odpowiednimi wartościami prądów występujących w tych przyrządach w warunkach zwarciowych w zespole przekształtnikowym. W związku z różnymi przebiegami prądu deklarowanego jako dopuszczalny w stosunku do przebiegów występujących w rzeczywistości, jako kryterium porównawcze przyjęto odpowiadające tym prądom wartości całek i2t. Jako kryterium zagrożenia eksplozją przyrządu energoelektronicznego przyjęto wartości całki i2t, powodującej eksplozję tego przyrządu, wyznaczoną w trakcie badań eksperymentalnych prowadzonych w zwarciowni prądu przemiennego. Analizy obliczeniowe prowadzono na przykładzie trakcyjnego zespołu prostownikowego o prądzie 1700 A i napięciu wyprostowanym 3,3 kV. Analizy prowadzone były metodą symulacyjną przy wykorzystaniu programu PSIM.
Method of protection against failure or explosion hazard of semiconductor power devices, which can occur in high power converters, is discussed. This method base on a comparing of the permissible over current declared by manufactures, with the short-circuit current that can appear in case of failure. Different case of failure was analyzed and new criterion for protection of the semiconductor power devices is proposed. Taking the declared current, and the calculated integral i2t as function of time, of the short circuit current, one is able to select circuit breaker operating time that should be applied in substation. This criterion assumed was verified with gut accuracy during experimental investigation in high current conditions. Tests were made at traction DC current unit of 3,3 kV and 1700 A.
Źródło:
Prace Instytutu Elektrotechniki; 2012, 258; 99-121
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jednofazowy silnik synchroniczny z magnesami trwałymi o rozruchu bezpośrednim. Konstrukcje magnetowodu
Single-phase line start permanent magnet synchronous motor. Magnetic circuit constructions
Autorzy:
Gwoździewicz, M.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/1369594.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
jednofazowy silnik
konstrykcje magnetowodu
single-phase motor
magnetic circuit constructions
Opis:
Politechnika Wrocławska Instytut Maszyn, Napędow i Pomiarow Elektrycznych Influence of the permanent magnet assembly on the single-phase permanent magnet synchronous motor on the running motor properties was investigated. Field-circuit synchronous motor models were applied in Maxwell ver. 14. EMF, THD and cogging torque were investigated. The optimum permanent magnet assembly motor solution with the best auxiliary winding parameters was presented.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 2, 95; 139-142
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
Autorzy:
Blakiewicz, G.
Jakusz, J.
Jendernalik, W.
Szczepański, S.
Powiązania:
https://bibliotekanauki.pl/articles/201440.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CMOS circuits
automatic tuning
impedance matching
resonant circuit
układy CMOS
tuning
impedancja
obwód rezonansowy
Opis:
In this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless power reception, fabricated in in AMS CMOS 0.35 μm technology, was used to verify correct operation of the proposed tuning. The prototype system produces a stable supply voltage, adjustable in the range of 1.2–1.8 V at a maximum output current of 100–67 mA, which is sufficient to power a typical endoscopic capsule.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 3; 641-646
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies