Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "circuit" wg kryterium: Wszystkie pola


Tytuł:
Positive continuous – time linear electrical circuit
Autorzy:
Piotrowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/376959.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
positive
non-positive
electrical circuit
linear
Opis:
The positive linear continuous-time systems by the use of the Caputo and conformable fractional calculus are analyzed. The conditions for internally positive systems are presented. For the established electrical circuit, a solution fractional order state-space equation was developed for system with Caputo and conformable fractional derivative (CFD) definition.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 93; 299-309
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An inductive proof of Whitneys Broken Circuit Theorem
Autorzy:
Dohmen, Klaus
Powiązania:
https://bibliotekanauki.pl/articles/743963.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
chromatic polynomial
broken circuit
induction
Opis:
We present a new proof of Whitney's broken circuit theorem based on induction on the number of edges and the deletion-contraction formula.
Źródło:
Discussiones Mathematicae Graph Theory; 2011, 31, 3; 509-515
2083-5892
Pojawia się w:
Discussiones Mathematicae Graph Theory
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical parameter identification of analog integrated circuit reverse models
Autorzy:
Apolloni, B.
Bassis, S.
Mesiano, C.
Rinaudo, S.
Ciccazzo, A.
Marotta, A.
Powiązania:
https://bibliotekanauki.pl/articles/1396732.pdf
Data publikacji:
2011
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Tematy:
analog circuit
circuit model
granular function
cluster
Spice
Opis:
We solve the manufacturing problem of identifying the model statistical parameters ensuring a satisfactory quality of analog circuits produced in a photolithographic process. We formalize it in a statistical framework as the problem of inverting the mapping from the population of the circuit model parameters to the population of the performances. Both parameters and performances are random. From a sample of the latter population we want to identify the statistical features of the former that produce a performance distribution complying with production samples. The key artifact of the solution method we propose consists of describing the above mapping in terms of a mixture of granular functions, where each is responsible for a fuzzy set within the input-output space, hence for a cluster therein. The way of synthesizing the whole space as a mixture of these clusters is learnt directly from the examples. As a result, we have an analytical form of the mapping that approximates complex Spice models in terms of polynomials in the model parameters, and an implicit expression of the distribution law of the induced performances that allows a relatively quick and easy management of the model distribution statistical parameters. This flows into a semiautomatic procedure managing an adaptive composition of different granular modules to cope with the circuit peculiarities. We check the method both on real world manufacturing problems and on ad hoc benchmarks.
Źródło:
Journal of Artificial Intelligence and Soft Computing Research; 2011, 1, 2; 115-134
2083-2567
2449-6499
Pojawia się w:
Journal of Artificial Intelligence and Soft Computing Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finding short-circuit current time based on raw data
Autorzy:
Książkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/376962.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
overcurrent
Scilab
histogram
short-circuit time
Opis:
Series of tests were conducted in which short-circuit current was registered. Four different overcurrent protection devices were used for a set value of prospective current. Based on obtained data the short-circuit time was calculated. In order to obtain this information a procedure was developed. Later it was implemented with the help of numerical computation software Scilab. In this paper results of calculations, the procedure itself and its implementation are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 213-218
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of performing Design FMEA on electronic circuit diagrams
Autorzy:
Karcz, R.
Powiązania:
https://bibliotekanauki.pl/articles/2069239.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
electronic circuit analysis
failure mode
TTAA
Opis:
Existing method of performing FMEA for electronic diagrams is time consuming task. For complex systems analysis of every single component failure mode and its effect deeply involves design team and blocks resources availability for long time. Method presented in this paper allows effective analysis of design failure modes using FMEA approach carrying so called Time to Acceptable Analysis (TTAA) constraint.
Źródło:
Journal of Polish Safety and Reliability Association; 2015, 6, 1; 125--128
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody ograniczania prądów zwarciowych w sieciach niskiego napięcia
The methods of short-circuit currents limitation in LV distribution networks
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/266492.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyłączniki hybrydowe
zwarcia
hybrid circuit breaker
short-circuit current
Opis:
Prezentuje się własności istniejących ograniczników prądu oraz nowego hybrydowego bezstykowego ogranicznika prądów zwarciowych, powstałego przez zastąpienia układu stykowego specjalnym bezpiecznikiem krótkotopikowym. Przedstawia się możliwość zastosowania go do ograniczania skutków łuku awaryjnego w rozdzielnicach nn oraz poprawy jakości energii elektrycznej przez eliminację zapadów napięcia w wyniku bardzo szybkiego wyłączania zwarcia.
A new idea of a hybrid contactless current limiter and the properties of existing current limiter are discussed. On the substitution of a special ultra-short fuse for a contact switch in the hybrid current limiter a new device has been obtained, suitable for fast short-circuit fault cleaning. The fuse role is only to operate at faulty conditions, forcing current transfer into a parallel semiconductor device. Then the current is interrupted at an appropriate instant. They can be helpful in the reduction of voltage dips. It is thought of as a last resort protection in high rated current circuits, like bud bars of switchboards.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 27; 73-78
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamiczne wyznaczanie parametrów elektrycznego obwodu szeregowego
Dynamic evaluation of series electric circuit parameters
Autorzy:
Arendt, R.
Powiązania:
https://bibliotekanauki.pl/articles/266667.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
nieliniowy obwód elektryczny
obwód szeregowy
wartości chwilowe w obwodzie nieliniowym
opis wektorowy obwodu prądu przemiennego
nonlinear electric circuits
series circuit
instantaneous values in nonlinear circuit
vector description of AC circuit
Opis:
Po załączeniu napięcia na skutek istnienia inercji prąd w obwodzie zaczyna narastać od wartości zerowej do znamionowej. W tym czasie narastają spadki napięć na rezystancjach (impedancjach obwodu) bo zaczynają obowiązywać prawa Kirchhoffa. Można utworzyć układ ze sprzężeniem zwrotnym (układ regulacji stałowartościowej bądź nadążnej), który poszukuje parametrów obwodu spełniających prawa Kirchhoffa – elementy nie muszą być liniowe. W artykule przedstawiono omówienie teoretyczne metodyki rozwiązywania obwodów z zastosowaniem programu MatlabSimulink oraz przykłady: nieliniowego obwodu prądu stałego, nieliniowego obwodu dla wartości chwilowych prądu przemiennego oraz liniowych obwodów prądu przemiennego, obliczanych dla wartości wskazowych.
After voltage switch on a current in circuit due to inertia existence start to grow from null to nominal value. Meanwhile grows the resistance (impedance) voltage drops to achieve Kirchhoff’s rule. We can use a circuit with feedback (constant value control system or follow-up control system), which search for circuit parameters fulfilling Kirchhoff’s rules – in such case elements can be nonlinear. In the paper theoretic bases of circuit solutions using Matlab-Simulink program are discussed. Examples of nonlinear circuit of DC, nonlinear circuit for instantaneous values of AC supplied circuit and linear AC circuit evaluated for vector values are presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 15-18
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwarcie awaryjne transformatora
Emergency short-circuit of the transformer
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2135014.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
zwarcie symetryczne
zwarcie awaryjne
prąd udarowy
transformer
symmetrical short-circuit
emergency short-circuit
surge current
Opis:
Jedną z prób przewidzianą w programie badań pełnych transformatorów nowych jest próba zwarcia. Sposób przeprowadzenia tej próby jest opisany w normie PN-EN 60076-5. W eksploatacji transformatorów, które pracują w sieci elektroenergetycznej, zdarzają się także zwarcia przypadkowe. Przykładem jest transformator 16 MVA, 110/20kV z wyjściem kablowym. Kabel został uszkodzony. Powstało zwarcie dwufazowe. Transformator uległ awarii. Bazując na tym przykładzie i wykorzystując schematy zastępcze, obliczono prąd udarowy przy zwarciu symetrycznym i prąd udarowy przy zwarciu dwufazowym. Oceniono przepięcia indukowane przy wyłączaniu prądu zwarcia. Wskazano przyczynę awarii transformatora.
One of the tests included in the test program for complete new transformers is the short-circuit test. The method of carrying out this test is described in the PN-EN 60076-5 standard. In the operation of transformers that operate in the power grid, accidental short-circuits also occur. An example is a 16 MVA, 110 / 20kV transformer with cable outlet. The cable has been damaged. A two-phase short circuit has arisen. The transformer has failed. Based on this example and using equivalent diagrams, the impulse current for symmetrical shortcircuit and the impulse current for two-phase short-circuit were calculated. The induced overvoltage when switching off the short-circuit current was assessed. The cause of the transformer failure is indicated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 11--19
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesne wyłączniki niskiego napięcia
The modern lv circuit-breaker
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/268092.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
interfejsy komunikacyjne
wyłączniki
komunikacja
circuit breaker
diagnostic
communication capability
Opis:
Nowoczesne systemy rozdziału energii stawiają przed wyłącznikami mocy coraz większe wymagania, przekraczające realizację funkcji ochronnych i zabezpieczeniowych. Z tego względu nowoczesna aparatura łączeniowa niskiego napięcia powinna spełniać wymagania stawiane przez zaawansowane systemy sterowania, uwzględniające przede wszystkim: możliwości komunikacyjne, wsparcie programowe, diagnostykę i moSliwości szybkiej archiwizacji zdarzeń.
Modern power distribution systems demand from circuit breaker more and more complex functions going beyond simple protection. Therefore, modern LV switchgear must comply witch new expectation defined by control systems concerning communication, ability of programming, monitoring, recording of events, etc.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 93-96
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorithms for calculation of electrical circuit state
Autorzy:
Timofeev, A.
Ushakov, P.
Powiązania:
https://bibliotekanauki.pl/articles/92838.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach
Tematy:
simulation
electrical circuit
resistor mode
R-2R ladder
Opis:
Algorithms of calculation of a state of an electric circuit with passive components are described. Algorithms are intended for usage in system of simulation of the mixed electronic devices. Each component of a circuit is presented by program model of high complexity. In this article the resistor model is described. Electric voltages in circuit nodes are calculated by method of summation of volt-ampere characteristics. Component models control iterations at calculation of circuit nodes voltage. Results of calculation of voltage in R-2R ladder of the digital-to-analog converter are presented.
Źródło:
Studia Informatica : systems and information technology; 2011, 1-2(15); 5-14
1731-2264
Pojawia się w:
Studia Informatica : systems and information technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of parallel resonance RLCα circuit with supercapacitor
Autorzy:
Walczak, J.
Jakubowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/97419.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
phase resonance
supercapacitor
parallel RLCα circuit
Opis:
The paper describes the results of analysis on the resonance phenomenon in a parallel RLCα circuit with supercapacitor modeled as a fractional-order capacitance. A complex, more accurate fractional-order model has been taken into analysis. Formulas for frequency characteristics and resonance conditions have been derived and presented by simulation studies of the concerned fractional-order system.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 30-37
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Circuit for Balancing Harmonic-Polluted Three-Phase Networks
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262835.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
harmonic analysis
power quality
load balancing
frequency scan
Steinmetz circuit
Opis:
This paper presents a new circuit capable of balancing harmonics-polluted three-phase power networks supplying single-phase loads. It takes into account the negative and positive sequences exhibited by the fifth and seventh harmonics, respectively. The concept extends the relations of the Steinmetz circuit, which are based exclusively on fundamental frequency considerations. The Steinmetz circuit does not, therefore, guarantee the balancing of the different harmonics in the line currents. Furthermore, it can lead to resonances between the capacitive and inductive elements in the two added balancing branches. A procedure for identifying the topology and the circuit parameters of the proposed connection is given. The results of a detailed case study are presented in order to demonstrate the superiority of the proposed circuit over the conventional Steinmetz connection.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2013, 16, 1; 19-24
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka wyłączników niskiego napięcia
The monitoring of LV circuit breaker
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/267606.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyłączniki nn
komunikacja
diagnostyka
circuit breaker
diagnostic
communication capability
Opis:
Nowoczesne systemy rozdziału energii stawiają przed wyłącznikami mocy coraz większe wymagania, przekraczające realizację funkcji ochronnych i zabezpieczeniowych. Z tego względu nowoczesna aparatura łączeniowa niskiego napięcia powinna spełniać wymagania stawiane przez zaawansowane systemy sterowania, uwzględniające przede wszystkim: możliwości komunikacyjne, wsparcie programowe, diagnostykę i możliwości szybkiej archiwizacji zdarzeń.
Modern power distribution systems demand from circuit breaker morę and morę complex functions going beyond simple protection. Therefore, modern LV switchgear must comply witch new expectation defined by control systems concerning communication, ability of programming, monitoring, recording of events, etc.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 97-100
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic equivalent circuit model for unipolar hybrid excitation synchronous machine
Autorzy:
Kupiec, E.
Przyborowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/141541.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hybrid excitation
magnetic equivalent circuit
synchronous machine
Opis:
Lately, there has been increased interest in hybrid excitation electrical machines. Hybrid excitation is a construction that combines permanent magnet excitation with wound field excitation. Within the general classification, these machines can be classified as modified synchronous machines or inductor machines. These machines may be applied as motors and generators. The complexity of electromagnetic phenomena which occur as a result of coupling of magnetic fluxes of separate excitation systems with perpendicular magnetic axis is a motivation to formulate various mathematical models of these machines. The presented paper discusses the construction of a unipolar hybrid excitation synchronous machine. The magnetic equivalent circuit model including nonlinear magnetization curves is presented. Based on this model, it is possible to determine the multi-parameter relationships between the induced voltage and magnetomotive force in the excitation winding. Particular attention has been paid to the analysis of the impact of additional stator and rotor yokes on above relationship. Induced voltage determines the remaining operating parameters of the machine, both in the motor and generator mode of operation. The analysis of chosen correlations results in an identification of the effective control range of electromotive force of the machine.
Źródło:
Archives of Electrical Engineering; 2015, 64, 1; 107-117
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the parallel resonance circuit with supercapacitor
Autorzy:
Walczak, J.
Jakubowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/376990.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
phase and magnitude resonance
parallel RLCα circuit
supercapacitor
Opis:
The article presents an analysis of phase resonance conditions for the parallel RLCα circuit with supercapacitor. Supercapacitors behaviour somehow differs from classic dielectric capacitors, therefore it is necessary to develop their new mathematical models, using fractional - order differential equations. A simple fractional - order supercapacitor model has been assumed, taking into account its internal equivalent series resistance ESR too. A lossless inductance has also been assumed and relations for equivalent admittance and resonance occurence conditions have been derived in the considered parallel RLCα circuit with supercapacitor. The analysis was conducted for different fractional-order parameter α values. Derived relations have been illustrated by simulation examples. The existence of resonance frequency depends largely on the supercapacitor series resistance value.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 77; 93-99
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydraulic circuit control of a steer by wire system
Autorzy:
Voženilek, R.
Maly, M.
Brabec, P.
Powiązania:
https://bibliotekanauki.pl/articles/245341.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
steer by wire
hydraulic circuit
control
Opis:
The future of cars will be connected with "by-wire" systems. The Technical University of Liberec, Department of vehicles and Engines has developed a design of testing equipment for directional control system testing. The objective of the newly designed equipment is to incorporate a wheel with a real tire and a flexible mounting of axle components. The paper describes properties and control of the hydraulic circuit consisting of two double-acting engines with a unilateral piston rod and two proportional valves (Parker D1FP). Each of the front axle wheels is controlled separately. The paper illustrates relationships andpotential of steer-by-wire systems at the experimental equipment. The safe and easy control of a vehicle undoubtedly poses significant requirements. Satisfying them and improving the design to enhance the vehicle's stability have always belonged to the primary objectives of designer s. Consequently, the chassis characteristics, the mechanical features of wheel suspensions, the quality of air suspensions, but also speed control (including brakes) and the vehicle 's directional control have always been emphasised. The objective of the paper was to design a steer-by-wire directional control mechanism with a suitable arrangement. The comparison focuses on various design options to arrange the action members (actuators) of this mechanism.
Źródło:
Journal of KONES; 2009, 16, 4; 477-483
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of analog circuit based on wavelet transform and neural network
Autorzy:
Wang, Hui
Powiązania:
https://bibliotekanauki.pl/articles/141368.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog circuit
fault diagnosis
neural network
wavelet transform
Opis:
Analog circuits need more effective fault diagnosis methods. In this study, the fault diagnosis method of analog circuits was studied. The fault feature vectors were extracted by a wavelet transform and then classified by a generalized regression neural network (GRNN). In order to improve the classification performance, a wolf pack algorithm (WPA) was used to optimize the GRNN, and a WPA-GRNN diagnosis algorithm was obtained. Then a simulation experiment was carried out taking a Sallen–Key bandpass filter as an example. It was found from the experimental results that the WPA could achieve the preset accuracy in the eighth iteration and had a good optimization effect. In the comparison between the GRNN, genetic algorithm (GA)-GRNN and WPA-GRNN, the WPA-GRNN had the highest diagnostic accuracy, and moreover it had high accuracy in diagnosing a single fault than multiple faults, short training time, smaller error, and an average accuracy rate of 91%. The experimental results prove the effectiveness of the WPA-GRNN in fault diagnosis of analog circuits, which can make some contributions to the further development of the fault diagnosis of analog circuits.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 175-185
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of fuzzy relational cognitive maps in intelligent modelling the technical systems
Autorzy:
Słoń, G.
Yastrebov, A.
Powiązania:
https://bibliotekanauki.pl/articles/376009.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
cognitive maps
electrical circuit
RLC circuit
Opis:
Certain approach to the modelling dynamic states in technical systems is presented in this paper. This approach lies in a replacing classic differential model with a model based on fuzzy relational cognitive map. Described method is illustrated by practical example of simple electrical RLC circuit. The method of the normalized reference data preparation was described. The process of building a cognitive map with concepts crucial from the modelling purposes point of view was presented also results of such a map teaching process were shown. In the end a partial comparison of simulation results of work of models: classic - based on the set of differential equations and proposed - based on fuzzy relational cognitive map was performed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 175-182
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analog Circuit Based on Computational Intelligence Techniques
Autorzy:
Oltean, G.
Hintea, S.
Şipos, E.
Powiązania:
https://bibliotekanauki.pl/articles/385049.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
analog circuit design
optimization
genetic algorithm
neuro-fuzzy systems
Opis:
This paper presents a new method for analog circuit design optimization. Our approach turns to good account the advantages offered by computational intelligence techniques. Design objectives can be expressed in a flexible manner using fuzzy sets. This way appears the possibility to consider different degrees for requirement achievements and acceptability degree for a particular solution. Neuro-fuzzy systems (universal approximators) are used to model the complex multi-variable and nonlinear circuit performances. These models satisfy two main requirements: high accuracy and low computation complexity. An efficient and robust genetic algorithm does avoiding local minima the exploration of the large, multidimensional solution space in quest for the optimal solution.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 2; 63-69
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear behavior analysis of split-winding dry-type transformer using a new star model and a coupled field-circuit approach
Autorzy:
Azizian, D.
Powiązania:
https://bibliotekanauki.pl/articles/140907.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coupled field circuit
electromagnetic modeling
split-winding dry-type transformer
nonlinear equivalent circuit
finite element
Opis:
Regarding the importance of short circuit and inrush current simulations in the split-winding transformer, a novel nonlinear equivalent circuit is introduced in this paper for nonlinear simulation of this transformer. The equivalent circuit is extended using the nonlinear inductances. Employing a numerical method, leakage and magnetizing inductances in the split-winding transformer are extracted and the nonlinear model inductances are estimated using these inductances. The introduced model is validated and using this nonlinear model, inrush and short-circuit currents are calculated. It has been seen that the introduced model is valid and suitable for simulations of the split-winding transformer due to various loading conditions. Finally, the effects of nonlinearity of the model inductances are discussed in the following.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 773-787
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum circuit breakers in high and highest voltage grids
Zastosowanie wyłączników próżniowych w sieciach wysokich i najwyższych napięć
Autorzy:
Kubek, P.
Powiązania:
https://bibliotekanauki.pl/articles/397039.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
vacuum insulation technology
vacuum circuit breaker
SF6 circuit breaker
próżniowa technika izolacyjna
wyłącznik próżniowy
wyłącznik SF6
Opis:
Recently, there has been a noticeable increase in the interest of grid operators in the application of vacuum technology in high and highest voltage overhead grids. For many years vacuum circuit breakers have been used in medium voltage grids, but in the past years mainly due to environmental conditions, vacuum technology has been developed also for high and highest voltages. Application of vacuum circuit breakers in high and highest voltage grids requires considering many technical factors that are characterized in this paper. Its main aim is to review the existing solutions of high voltage vacuum circuit breakers and to compare them with SF6 gas circuit breakers. It also discusses technical aspects of high voltage vacuum circuit breakers’ disadvantages and advantages, as well problems of their designing.
W ostatnim czasie można zauważyć intensywny wzrost zainteresowania operatorów sieciowych wykorzystaniem techniki próżniowej w sieciach napowietrznych wysokiego i najwyższego napięcia. Od wielu lat wyłączniki próżniowe są stosowane w sieciach średniego napięcia, jednak w minionych latach głównie ze względu na uwarunkowania środowiskowe technologia próżniowa rozwijana jest także w zakresie wysokich i najwyższych napięć. Zastosowanie wyłączników próżniowych w sieciach WN i NN wymaga uwzględnienia wielu czynników technicznych, które scharakteryzowano w artykule. Głównym celem artykułu jest dokonanie przeglądu istniejących rozwiązań wyłączników próżniowych wysokiego napięcia oraz ich porównanie z wyłącznikami z gazem SF6. Artykuł zawiera także omówienie aspektów technicznych dotyczących wad i zalet, a także problemów dotyczących projektowania wyłączników próżniowych wysokiego napięcia.
Źródło:
Acta Energetica; 2017, 3; 124-130
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czasy wyłączania magnetowydmuchowych wyłączników szybkich prądu stałego
Switching-off Time of Electromagnetic Blow-out High-speed DC Circuit Breaker
Autorzy:
Rojek, A.
Powiązania:
https://bibliotekanauki.pl/articles/215436.pdf
Data publikacji:
2015
Wydawca:
Instytut Kolejnictwa
Tematy:
wyłącznik szybki
zwarcia
czas własny
czas łukowy
high-speed circuit breaker
short-circuit
opening time
arcing time
Opis:
Wyłączniki szybkie są podstawowym zabezpieczeniem przed przepływem nadmiernych wartości prądu w obwodach sieci trakcyjnej oraz zasilanych z niej pojazdów. Prądy zwarciowe muszą być wyłączone w jak najkrótszym czasie, aby zminimalizować ryzyko uszkodzenia chronionych przez wyłączniki elementów systemu zasilania trakcji elektrycznej. Jednym z istotnych parametrów wyłącznika szybkiego jest czas wyłączania prądu, określany od chwili przekroczenia przez prąd nastawy wyzwalacza wyłącznika do chwili wyłączenia prądu. Zakres badań wyłączników szybkich prądu stałego na zgodność z normami obejmuje określenie tego czasu jedynie dla dużych wartości prądu, znacznie przekraczających poziom prądów roboczych, oraz dla prądów o wartości bardzo małej – prądów krytycznych. Podczas eksploatacji wyłączników szybkich najwięcej wyłączeń następuje w wyniku zwarć odległych lub przeciążeń. W celu określenia rzeczywistych czasów wyłączania prądów o wartościach porównywalnych z poziomem nastawy wyzwalacza wyłącznika szybkiego, przeprowadzono badania przy różnych wartościach stałej czasowej obwodu, w wyniku których określono czas łukowy oraz czas własny wyłącznika w zależności od wartości wyłączanego prądu. Badaniom poddano magnetowydmuchowy wyłącznik szybki prądu stałego typu BWS, który jest najczęściej używanym w Polsce wyłącznikiem w podstacjach trakcyjnych i kabinach sekcyjnych.
The high-speed circuit breakers are an essential safeguard against the flow of an excessive current in the circuit overhead line and vehicles being powered by it. The short circuit currents must be switched off as soon as possible to minimize the risk of damage, protected by circuit breakers, elements of an electric traction power supply system. The switching-off time is one of the main parameters of high-speed circuit- breaker. This time is specified from moment of exceeding of the circuit breaker tripping level by the current until cut off the current. The scope of high-speed DC circuit breakers tests for compliance with standards includes determining this time only for large currents, greatly exceeding the operating currents, and the currents of the very small – critical currents. However, during exploitation of high-speed circuit-breakers many faults clearance occurs by distant short-circuits or overloads. In order to determine the actual switching times of currents, which values are comparable with the tripping level researches and tests were performed for different values of the time constant, which were base of specifying value of arcing and opening time, depending on the value of breaking currents. The study involved electromagnetic blow-out high-speed DC circuit breaker BWS type, which is the most common breaker in traction substations and sectioning cabins in Poland.
Źródło:
Problemy Kolejnictwa; 2015, 169; 53-60
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short-circuit duration and dynamic forces in central section of substation
Autorzy:
Frąckowiak, R.
Piechocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/97305.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
EHV distribution substations
short-circuit dynamic effects
simulations
Opis:
Presented topic is the continuation of investigations concerning the estimation of short-circuit duration when computing the short-circuit effects using probabilistic methods. In the paper, an expanded model of distribution substation for simulation-based analysis of the short-circuit conditions and dynamic effects in the central section of bus-bar is presented. In the model, the operation of protections in the transformer bay has also been considered. The results of simulations aiming to assess the frequency of occurrence of the defined values of short-circuit current, short-circuit duration and dynamic forces are reported. Also, the question: “How the transformer’s protections involved in simulation affect the simulated short-circuit conditions?” has been answered. Computations have been carried out for four different EAZ system configurations.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 220-230
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Arc models for simulating processes in circuits with a SF6 circuit breaker
Autorzy:
Sawicki, Antoni
Powiązania:
https://bibliotekanauki.pl/articles/140610.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
switching arc
high-voltage circuit breaker
Mayr model
Opis:
This paper demonstrates that if a linear dependence of arc dissipated power on power supplied is introduced at an initial stage of analysis, then, with some simplifying assumptions, the classical Mayr model is obtained. Similarly, if this dependence is taken into account in a model with residual conductance, the modified Mayr model is obtained. The study takes into consideration the local phenomenon of sudden voltage drop accompanying linear current decrease occurring in the circuit breaker. To account for this phenomenon, the Dirac delta function and its approximation by a Gaussian function, representing power or enthalpy disturbances, are introduced to the power balance equation. It is demonstrated that both variants yield the same effect, leading to identical differential equations. Macromodels of the circuit-breaker arc are created and connected with the power source circuit with lin- early decreasing current. The results obtained were found to be consistent with experimental data available in the literature. The models presented are based on a fairly uncomplicated 1st order differential equation and offer a straightforward physical interpretation of the phenomena in question.
Źródło:
Archives of Electrical Engineering; 2019, 68, 1; 147-159
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field-circuit analysis of AC machine taking into account stator winding asymmetry
Autorzy:
Pietrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1813709.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
winding asymmetry
induction machine
axial flux
field-circuit model
Opis:
The paper presents the influence of an asymmetry of a stator winding on an axial flux in AC machine. The objective research was performed for selected values of asymmetry. The axial flux was calculated as the sum of flux linkage with stator winding. In order to achieve a magnetic field distribution a dedicated 2D finite element model of AC machine was elaborated. The waveforms of axial flux and torque-time characteristic have been shown. It can be concluded that the asymmetry has significant impact on the axial flux and the pulsation of torque.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 386-392
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two heuristic alghorithms for test point selection in analog circuit diagnoses
Autorzy:
Pułka, A.
Powiązania:
https://bibliotekanauki.pl/articles/221005.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analog circuit diagnosis
fault diagnosis
testing
search methods
heuristic optimization
Opis:
The paper presents a heuristic approach to the problem of analog circuit diagnosis. Different optimization techniques in the field of test point selection are discussed. Two new algorithms: SALTO and COSMO have been introduced. Both searching procedures have been implemented in a form of the expert system in PROLOG language. The proposed methodologies have been exemplified on benchmark circuits. The obtained results have been compared to the others achieved by different approaches in the field and the benefits of the proposed methodology have been emphasized. The inference engine of the heuristic algorithms has been presented and the expert system knowledge-base construction discussed.
Źródło:
Metrology and Measurement Systems; 2011, 18, 1; 115-128
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The electromagnetic calculations of complex motion common magnetic circuit electromagnetic converter
Autorzy:
Kamiński, G.
Góralski, P.
Powiązania:
https://bibliotekanauki.pl/articles/140891.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical machines
common magnetic circuit
torque relative error
Opis:
This document contains results of research on complex motion common magnetic circuit electromagnetic converter characteristic that allows making independent axial and rotary shaft motion. The converter in addition to linear-rotary mechanism consists of two drive rotors and one common magnetic circuit excitator. Such a solution allows to reduce volume of the machine and makes it easier to use. The paper cites design intent and possible structure of the device. Phenomenon of common magnetic circuit adverse effect on correct operation of device is discussed. The concept of using relative error as a way to evaluate the influence of that phenomenon in the torques is discussed. Waveforms of determined relative errors for all possible cases is presented. Furthermore the concept of average relative error is defined and its use as a quantitative method of assessing the degree of common circuit impact is indicated. Definition of relative error ripple factor is given, and its usage is shown. Winding inductance calculation based on free FEM application is shown and its influence on control strategy and power system.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 125-133
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Superstabilization of positive linear electrical circuit by state-feedbacks
Autorzy:
Kaczorek, T.
Powiązania:
https://bibliotekanauki.pl/articles/201246.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
positive
electrical circuit
superstability
state-feedback
pozytywny
obwód elektryczny
superstabilność
informacja zwrotna
Opis:
The concept of superstability of positive linear electrical circuits is introduced and its properties are characterized. The superstabilization of positive and nonpositive electrical circuits by state-feedbacks is analyzed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 703-708
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu warunków zwarciowych na dobór elementów sieci elektroenergetycznej
The influence of short circuit conditions for choosing elements of power network
Autorzy:
Gancarz, A.
Walat, W.
Powiązania:
https://bibliotekanauki.pl/articles/268346.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
sieci rozdzielcze
warunki zwarciowe
wytrzymałość zwarciowa
distribution networks
short-circuit conditions
short-circuit strength
Opis:
W publikacji przedstawiono wpływ warunków zwarciowych na pracę sieci przemysłowych. W szczególności uwzględniono sytuację, w której dochodzi do zmiany mocy zwarciowej lub struktury sieci odbiorczej. W badaniach podjęto próbę wykazania, Se szczegółowe uwzględnienie stopnia obciążenia elementów sieci moSe wpłynąć na ograniczenie nakładów finansowych na jej modernizację.
The paper presents the influence of short-circuit conditions on industrial power networks. It mainly includes the problem of changing short-circuit power or the structure of power network. The attempt was taken to prove that including load range of power network may result in decreasing total costs of modernization.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 46-48
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyłączanie prądów zwarciowych przez wyłączniki szybkie w podstacjach trakcyjnych
Short Circuit Current Breaking by High Speed Circuit Breakers in Traction Substation
Autorzy:
Rojek, A.
Powiązania:
https://bibliotekanauki.pl/articles/215669.pdf
Data publikacji:
2017
Wydawca:
Instytut Kolejnictwa
Tematy:
czas wyłączania
napięcie łuku
badania wyłączników szybkich
breaking time
arc voltage
high speed circuit breakers tests
Opis:
Wyłączniki szybkie stosowane w podstacjach trakcyjnych muszą spełniać wiele wymagań, od czego zależy ich prawidłowa praca, co przekłada się na bezpieczeństwo i ruch pociągów. Z tego względu przed dopuszczeniem do eksploatacji wyłączników szybkich, przechodzą one liczne badana laboratoryjne, w tym na zgodność z wymaganiami norm PN-EN 50123-1 i PN-EN 50123-2. Z uwagi na to, że zapisy norm są ogólne, a czasem mało precyzyjne, wyniki badań laboratoryjnych nie zawsze przekładają się na parametry wyłączników podczas eksploatacji w warunkach rzeczywistych. W  niniejszym artykule przedstawiono zagadnienie dotyczące wyłączania prądu stałego oraz wpływu parametrów obwodu na czas wyłączania. Podano przykład, w którym ten sam typ wyłącznika badany w układzie spełniającym wymagania normy, lecz o różnych parametrach, może spełniać lub nie wymagania dotyczące całkowitego czasu wyłączania. W artykule odniesiono się również do innego parametru wyłącznika szybkiego, jakim jest wartość przepięcia łączeniowego. Przedstawiono wyniki badań, na podstawie których określono wartość maksymalną przepięcia łączeniowego dopuszczalną dla wyłączników pracujących w podstacjach trakcyjnych w Polsce. W ten sposób odniesiono się do zapisów norm branżowych określających, że wartość przepięć łączeniowych może być określona przez użytkownika wyłączników szybkich prądu stałego.
High speed circuit breakers (HSCB) applied in traction substations must meet several requirements conditioning their proper performance, which enhances train safety and traffic. Due to this fact, prior to high speed circuit breakers placing into operation, they are subject to several laboratory tests, including tests checking compliance with PN-EN 50123-1 and PN-EN 50123-2 standards requirements. As many provisions of standards are general and sometimes not very precise, laboratory tests results do not always translate into HSCB parameters in operational use under realistic conditions. The article features the issue concerning DC breaking and the impact of the circuit parameters on the breaking time. An example was given when the same HSCB type was tested in a circuit which meets the standard requirements but bears diff erent parameters and that type can or not fulfi ll the requirements relating to the total breaking time. The article also refers to another HSCB parameter, i.e. the value of switching overvoltage. The test results were presented which were the basis to determine the maximum limit value of switching overvoltage for breakers installed in traction substations in Poland. In this way the reference was made to provisions of industry standards which state that the value of switching overvoltage may be determined by a HSCB user.
Źródło:
Problemy Kolejnictwa; 2017, 177; 51-59
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Joule’s heat generated during a short-circuit current flow in function of phase angle
Autorzy:
Książkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/97577.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
Joule's heat
circuit breaker
let-through energy
Opis:
Joule's heat (let-through energy) is an important factor in proper protection of electrical installations and devices. Studies were preformed during which the relationship between amount of energy and phase angle of short-circuit current was examined. Typically used miniature circuit breaker was utilized as a protective device. Scilab software for numerical computation was used to calculate the let-through energy based on recorded oscillograms of short-circuit current. Results of this calculations are presented.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 162-170
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the transient state in a circuit with supercapacitor
Autorzy:
Jakubowska, A.
Walczak, J.
Powiązania:
https://bibliotekanauki.pl/articles/377512.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
fractional-order differential equation
first-order RCα circuit
supercapacitor
Opis:
The paper presents an analysis of the transient state in a simple circuit of RCα class with a supercapacitor. The behavior of supercapacitors differs from that of classic capacitors, which influences voltage and current waveforms in circuits containing them. The waveforms are described by relations of fractional-order integral-differential calculus. A simple fractional-order supercapacitor model, including its series internal resistance, has been assumed for the analysis. The obtained solution of the fractional-order differential equation describing the examined circuit is presented. The impact of different values of the parameter α on the solution has been analyzed too. The derived relations are illustrated by simulation examples for the circuit powered by a DC voltage source. This situation describes the supercapacitor charging process. Its charging time depends mainly on the value of fractional-order parameter α of the supercapacitor.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 81; 71-77
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Let-through energy of miniature circuit breaker in function of phase angle of short-circuit current
Autorzy:
Książkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/377379.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
MCB
let-through energy
Joule's heat
Opis:
Let-through energy (Joule heat) is an important factor in proper protection of electrical installations and devices. Studies were preformed during which the relationship between amount of energy and phase angle of short-circuit current was examined. Typically used miniature circuit breaker was utilized as a protective device. Scilab software for numerical computation was used to calculate the let-through energy based on recorded oscillograms of short-circuit current. Results of this calculations are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 78; 59-64
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stimulus with limited band optimization for analogue circuit testing
Autorzy:
Golonek, T.
Jantos, P.
Rutkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/221641.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
analogue circuit testing
faults isolation
evolutionary computations
amplitude spectrum
Opis:
The paper presents an analogue circuit testing method that engages the analysis of the time response to a nonperiodic stimulus specialized for the verification of selected specifications. The decision about the current circuit diagnostic state depends on an amplitude spectrum decomposition of the time response measured during the test. A shape of the test excitation spectrum is optimized with the use of a differential evolution algorithm and it allows for achieving maximum fault coverage and the optimal conditions for fault isolation. Genotypes of the evolutionary system encode the amplitude spectrum of candidates for testing stimuli by means of rectangle frequency windows with amplitudes determined evolutionarily.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 73-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transitional processes at capacitive currents switching-off by single and double-break interrupters of vacuum circuit breakers
Autorzy:
Lazimov, T.
Saafan, E.
Powiązania:
https://bibliotekanauki.pl/articles/410591.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
vacuum circuit breaker
double-break vacuum interrupters
SF6 circuit breaker
capacitor banks
transient recovery voltage
dielectric strength
breaking capacity
Opis:
Vacuum circuit breaker technology based on double-break vacuum interrupters has become the most requirements of high voltage circuit breakers that not environmentally harmful. The vacuum interrupter has an excellent ability to deal with the steep rising part of the transient recovery voltage, which makes it faster in the current interruption process. This paper presents results of computer simulations conditioned by capacitive currents switching-offs by using single and double interrupters of vacuum circuit breakers. These results demonstrate that use of double-break circuit breakers leads to notable decreasing of switching overvoltages and allows in the same time to meet the dielectric requirements for high voltage vacuum circuit breakers.
Źródło:
Present Problems of Power System Control; 2014, 5; 33-43
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ pomiaru symetrycznych i asymetrycznych prądów zwarciowych z zastosowaniem wielozakresowych przekładników prądowych w warunkach laboratorium zwarciowego
The system of measurement of symmetrical and asymmetric short circuit current with multi range current transformers in conditions of short-circuit testing laboratory
Autorzy:
Babiuch, Michał
Olak, Jan
Powiązania:
https://bibliotekanauki.pl/articles/267651.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
badania zwarciowe
pomiar prądów zwarciowych
przekładnik prądowy
short-circuit test
short-circuit current measurement
current transformer
Opis:
W artykule przedstawiono różne wymagania zawarte w normach przedmiotowych, dotyczące parametrów probierczych dla aparatury elektroenergetycznej i różnych rodzajów badań wykonywanych w laboratorium zwarciowym. Opisano wyposażenie badawczo pomiarowe Zwarciowni Instytutu Elektrotechniki w Warszawie (IEL). Przedstawiono układ pomiaru prądów zwarciowych przy użyciu nowo opracowanych przekładników. Opisano metodę sprawdzenia dokładności przekładników prądowych do pomiaru prądów zwarciowych i zamieszczono przykładowe wyniki i oscylogramy z badań. Układ został wdrożony i jest eksploatowany w Zwarciowni IEL.
The article contains an overview of various requirements for the parameters of the Short-Circuit Testing Laboratory: symmetrical and asymmetrical short-circuit currents, time constant for the disappearance of the constant short-circuit component, asymmetrical peak factor and various types of short-circuit tests performed on various devices operating in power systems, contained in different subject standards . The equipment of the Short-Circuit Testing Laboratory of the Electrotechnical Institute and the modernized test chamber No. 6 is described, equipped with new multi range current transformers and a modern measuring system for short-circuit current. The method of checking the accuracy of current transformers for measuring short-circuit currents is described and example oscillograms are given. The values of the adopted parameters of the transformers and the way of designing the test track are highlighted, enabling the simplification of preparatory works to carry out short-circuit tests and research organization. The article contains electrical diagrams of measurement systems, diagrams of current transformer windings and photograph of modernized test chamber No. 6.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of hydraulic circuit in mechatronic systems
Stosowanie obwodu hydraulicznego w systemach mechatronicznych
Autorzy:
Tropp, M.
Bastovansky, R.
Powiązania:
https://bibliotekanauki.pl/articles/101808.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
hydraulic circuit
MATLAB
simulation
obwód hydrauliczny
symulacje
Matlab
Opis:
This paper focuses on the calculations of basic variables of the hydrostatic circuits in the mechatronic systems. These calculations are important for machines used for forming materials by means of great forces, e.g. hydraulic press. Due to differences in equipment design, lack of a universal method of calculation is noticeable. It is necessary to determine the coefficients required for the calculations in an experimental way.
Tematem niniejszego artykułu jest obliczanie zmiennych podstawowych w obwodach hydrostatycznych w systemach mechatronicznych. Obliczenia te są wykonywane w mechatronice i wykorzystywane w maszynach do formowania materiałów za pomocą wielkich sił (prasa hydrauliczna). Zauważalny jest brak uniwersalnej metody obliczeń ze względu na różnice w konstrukcji urządzeń, stąd też konieczne jest wyznaczanie potrzebnych do obliczeń współczynników w sposób eksperymentalny.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2016, 2, 1; 5-10
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości komunikacyjne nowoczesnych wyłączników niskiego napięcia
The communication capability of modern LV circuit-breaker
Autorzy:
Leśniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/268030.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyłączniki mocy
diagnostyka
komunikacja
circuit breaker
diagnostic
communication capability
Opis:
Nowoczesne systemy rozdziału energii stawiają przed wyłącznikami mocy coraz większe wymagania, przekraczające realizację funkcji ochronnych i zabezpieczeniowych. Z tego względu nowoczesna aparatura łączeniowa niskiego napięcia powinna spełniać wymagania stawiane przez zaawansowane systemy sterowania, uwzględniające przede wszystkim: możliwości komunikacyjne, wsparcie programowe, diagnostykę i możliwości szybkiej archiwizacji zdarzeń.
Modern power distribution systems demand from circuit breaker more and more complex functions going beyond simple protection. Therefore, modern LV switchgear must comply witch new expectation defined by control systems concernilg communication, ability of programming, monitoring, recording of events, etc.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 25; 91-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On Transformation of a Logical Circuit to a Circuit with NAND and NOR Gates Only
Autorzy:
Baranov, S.
Karatkevich, A.
Powiązania:
https://bibliotekanauki.pl/articles/963932.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
logic synthesis
logic devices
VLSI
minimization
Opis:
In the paper we consider fast transformation of a multilevel and multioutput circuit with AND, OR and NOT gates into a functionally equivalent circuit with NAND and NOR gates. The task can be solved by replacing AND and OR gates by NAND or NOR gates, which requires in some cases introducing the additional inverters or splitting the gates. In the paper the quick approximation algorithms of the circuit transformation are proposed, minimizing number of the inverters. The presented algorithms allow transformation of any multilevel circuit into a circuit being a combination of NOR gates, NAND gates or both types of universal gates.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 3; 373-378
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania obwodu pneumatycznego z korektorem siły hamowania pojazdu
Research of the pneumatic circuit with the proof-reader of the brake force of the vehicle
Autorzy:
Czaban, J.
Miatluk, M.
Powiązania:
https://bibliotekanauki.pl/articles/262927.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
obwód hamulcowy
obwód pneumatyczny
siła hamowania
zawór korygujący
brake circuit
corrector valve
pneumatic circuit
Opis:
W pracy przedstawiono metodykę wyznaczania i identyfikacji charakterystyk statycznych i dynamicznych zaworu korygującego siłę hamowania 975 002. Otrzymane wyniki wykorzystano w obliczeniach dynamicznych obwodu hamulcowego samochodu ciężarowego z zaworem korygującym siłę hamowania. Przedstawiono wykresy przebiegu ciśnień w różnych punktach obwodu hamulcowego.
The paper presents the methodic of getting and identification of static and dynamic characteristics of the 975 002 corrector valve of the brake force. The obtained results were applied in dynamic calculations of the truck brake circuit with corrector valve of the brake force. Graphs of pressures changes in different points of the brake circuit are presented.
Źródło:
Archiwum Motoryzacji; 2008, 2; 121-132
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie fizyczne toru przewodowego przy ocenie iskrobezpieczeństwa obwodów i systemów elektrycznych
Metallic circuit physical modeling for spark-proof safety assessment of electric circuits
Autorzy:
Skoropacki, W.
Powiązania:
https://bibliotekanauki.pl/articles/340945.pdf
Data publikacji:
2003
Wydawca:
Główny Instytut Górnictwa
Tematy:
iskrobezpieczeństwo
obwód elektryczny
system elektryczny
tor przewodowy
iskiernik
spark-proof safety
electric circuit
electric system
metallic circuit
spark gap
Opis:
Jedną z metod określenia poziomu iskrobezpieczeństwa obwodów i systemów elektrycznych zawierających tory przewodowe (linie długie) jest metoda polegająca na wykorzystaniu iskiernika. W celu właściwego przeprowadzenia badań za pomocą iskiernika należy posługiwać się prawidłowym modelem fizycznym toru przewodowego (macierzystego), w postaci kaskadowego połączenia pasywnych symetrycznych czwórników, typu "T", "Π" i "X", zbudowanych ze skupionych elementów R, L, C, których wartości są równe odpowiednim parametrom toru macierzystego. Czwórniki te najczęściej symulują odcinki toru macierzystego o znanych parametrach jednostkowych Rj, Lj, Cj i Gj. Modelowanie toru przewodowego za pomocą pasywnych czwórników wymaga spełnienia dwóch kryteriów: - sumaryczna wartość elektromagnetycznej energii zgromadzonej w elementach reaktancyjnych czwórników zastępczych powinna być adekwatna do wartości energii zgromadzonej w naturalnym torze przewodowym, - charakterystyki amplitudowo-częstotliwościowe kaskady czwórników zastępczych i toru przewodowego powinny być zbieżne w wymaganym paśmie pulsacji, tak w stanie jałowym, jak i w stanie dopasowania falowego. Określono podstawowe warunki zastępowania toru przewodowego minimalną liczbą pasywnych czwórników, przy zachowaniu adekwatnej zdolności gromadzenia i przekazywania energii elektrycznej do punktu komutacji awaryjnej. Ocena modelu fizycznego została dokonana na podstawie określenia zbieżności charakterystyk amplitudowo-częstotliwościowych kaskady czwórników zastępczych i odcinka toru przewodowego w stanie jałowym i w stanie dopasowania falowego. Ustalono, że zastępowanie jednostkowego odcinka toru przewodowego jednym czwórnikiem nie odwzorowuje parametrów falowych toru macierzystego kabla w stanie jałowym i dopasowania falowego, co jest konieczne w badaniach, za pomocą iskiernika zapalności obwodu elektrycznego z torem przewodowym, ponieważ podczas wyładowania elektrycznego rezystancja kanału wyładowania zmienia się od 0 do ∞ (przy awaryjnym rozwarciu obwodu) lub od ∞ do 0 (przy awaryjnym zwarciu). Zakres pulsacji, dla którego wymagana jest zbieżność charakterystyk amplitudowo-częstotliwościowych toru przewodowego i kaskady czwórników zastępczych powinien być określany dla każdego konkretnego przypadku z uwzględnieniem parametrów źródła zasilania, zabezpieczenia przeciwwybuchowego i środowiska wybuchowego.
One of the methods used for determination of spark-proof safety of electric systems including metallic circuits is based on the use of spark gap. An appropriate physical model of metallic circuit is indispensable for that purpose. Such model is built in the form of a cascade of two-terminal-pair networks of "T", "Π" and "X" type, consisting of lump R, L, C elements and having parameters equal to the respective parameters of the metallic circuit. Usually two-terminal-pair networks emulate sections of metallic circuit whose unitary parameters Rj, Lj, Cj and Gj are known. The two following criteria should be met in order to secure a good emulation of metallic circuit by passive two-terminal-pair networks: - sum of electromagnetic energy accumulated in elements of two-terminal-pair networks should be adequate to the value of energy accumulated in the natural metallic circuit, - attenuation-frequency diagrams of the cascade of two-terminal-pair networks and the diagrams of metallic circuit should converge in the requested range of pulsation both in the idle state and in the state of impedance matching, The essential conditions were determined for metallic circuit modeling by minimal number of two-terminal-pair networks with ability preserved for accumulation of electric energy and its transfer to the emergency commutation point. The assessment of physical model was carried out by determination of convergence of diagrams of a section of the metallic circuit and a cascade of two-terminal-pair networks both the idle state and in the state of impedance matching. It has been determined that the substitution of a single section of the metallic circuit by one two-terminal-pair network in spark gap testing does not represent adequately wave parameters of metallic circuit of the cable both in the idle or impedance matching states. It is so because the resistance of the discharge channel changes from 4 to 0 (in the case of emergency circuit opening) or from 0 to 4 (in the case of emergency shorting). The pulsation range for which convergence is required of attenuation-frequency diagrams of a cascade of two-terminal-pair networks and diagrams of a metallic circuit should be determined in each particular case.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2003, 2; 33-48
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A field-circuit model of the hybrid magnetic bearing
Autorzy:
Wajnert, Dawid
Powiązania:
https://bibliotekanauki.pl/articles/140245.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dynamic simulation
field-circuit model
hybrid magnetic bearing
symulacja dynamiczna
model polowo-obwodowy
hybrydowe łożysko magnetyczne
Opis:
The paper presents a simulation model of the hybrid magnetic bearing dedicated to simulations of transient state. The proposed field-circuit model is composed of two components. The first part constitutes a set of ordinary differential equations that describes electrical circuits and mechanics. The second part of the simulation model consists of parameters such as magnetic forces, dynamic inductances and velocity-induced voltages obtained from the 3D finite element analysis. The MATLAB/Simulnik software was used to implement the simulation model with the required control system. The proposed field-circuit model was validated by comparison of time responses with the prototype of the hybrid magnetic bearing.
Źródło:
Archive of Mechanical Engineering; 2019, LXVI, 2; 191-208
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical Modeling of Stress in Circuit Cards Represented by Mechanical Oscillatory Systems
Autorzy:
Kovtun, Igor
Goroshko, Andrii
Petrashchuk, Svitlana
Powiązania:
https://bibliotekanauki.pl/articles/2022447.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
oscillatory system
dynamic force
stress
deflection
circuit card
resonance
Opis:
The represented paper is aimed at stress calculation in circuit cards with their representation as a type of mechanical oscillatory systems in purpose of their strength assessment especially in resonance conditions. Three types of oscillatory systems are researched: single-mass; multiple mass and oscillatory system with uniformly distributed mass. In all types the cylindrical bending of circuit cards is considered to be a set of beam-strips with rectangular cross-sections so their stress calculation is performed by conventional methods applied in strength of materials and civil engineering. Mathematical model has been developed for maximal dynamic stress and deflection estimation in circuit card assemblies represented by unique oscillatory system as prismatic beam set on two oscillating supports under inertial resonance excitation generated by constant dynamic force. Comparative analysis of mathematical modeling, MatLab simulation and experimental determination of maximal dynamic stress and deflection accomplished for three types of oscillatory systems verified proximity of obtained results. Single-mass oscillatory system is proposed as equivalent to multiple mass or uniformly distributed oscillatory systems on condition of their equal mass, geometric, elastic and dissipation characteristics in resonance frequency correspondent to the main mode of oscillation, so mathematical model designed for single-mass oscillatory system is recommended for strength and stiffness assessment in engineering calculations where possible difference in determination of stress in equivalent systems can used as safety factor.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 1; 303-315
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prioritization approach for circuit breakers to equip with condition monitoring devices
Autorzy:
Karimabadi, Ali
Hajiabadi, Mohammad Ebrahim
Kamyab, Ebadollah
Powiązania:
https://bibliotekanauki.pl/articles/140753.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
circuit breakers
condition monitoring
outage rate
reliability
smart sensor
Opis:
Circuit Breakers (CBs) play an important role in ensuring the safe operation of protection systems. Condition Monitoring (CM) devices are widely implemented to extend lifetime, and to improve the maintenance quality. The present paper proposes a cost-based prioritization approach for CBs in a network equipped with CM devices. To this end, a mathematical formulation is developed for the categorization and modeling of equipment failures based on their severity. This formulation quantifies the effect of the CM devices on the outage rate of the equipment. The reliability parameters of the substations 400/132/20 KV, including the failure rate, λ, average repair time, r, average outage time, U, substations, in two status of without CM and with CM of the CBs are calculated. These parameters are calculated implementing a minimal cut-set method. The outage rate of equipment with and without the CM devices is used to determine the effect of the CM devices on the reliability of the network. Finally, the prioritization of substations to install the CM devices on the CBs has been investigated in terms of the Expected Energy Not Supplied (EENS) and costs of CM. To verify the effectiveness and applicability of the method, the proposed approach is applied to the CBs in the power transmission network in the Khorasan Regional Electricity Company (KREC) in Iran.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 403-422
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of snubber circuit design for SiC power MOSFET devices
Autorzy:
Niewiara, Ł. J.
Skiwski, M.
Tarczewski, T.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/97236.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
DC\DC converter
snubber circuit
SiC MOSFET
Opis:
In this paper a design process of snubber circuit for DC\DC converter is presented. Computer simulation and experimental tests were carried out. Due to the presence of parasitic LC (inductance and capacitance) circuit in the power stage, it is necessary to use an additional snubber circuit for voltage overshoot and oscillations reduction. A simulation model of the converter with parasitic circuit was designed. Six topologies of snubber circuits (C, single C, RC, single RC, RCD, single RCD) were investigated in simulation tests. Simulation model of the proposed system has been investigated in Matlab/Simulink/PLECS environment. Input signal parameters like voltage overshoot, rise time, fall time were compared for considered snubber circuits. Experimental tests were carried out for the best simulation results. It confirm the proper choice of snubber circuit.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 120-131
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of fractional electrical circuit with rectangular input signal using Caputo and conformable derivative definitions
Autorzy:
Piotrowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/140842.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fractional order system
Caputo definition
conformable fractional definition
fractional electrical circuit
Opis:
An analysis of a given electrical circuit using a fractional derivative. The statespace equation was developed. The dynamics of tensions described by Kirchhoff’s laws equations. The paper used the definition of the integral derivative Caputo and CDF conformable fractional definition. An electrical circuit solution using Caputo and CDF definitions for rectangular with zero initial conditions was developed. The results obtained using the Caputo and CDF definitions were compared. The solutions are shown for capacitor voltages, for fractional derivative orders of 0.6, 0.8, 1. The results were compared using graphs.
Źródło:
Archives of Electrical Engineering; 2018, 67, 4; 789-802
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unidirectional Protection Strategy for Multi-terminal HVDC Grids
Autorzy:
Mokhberdoran, A.
Silva, N.
Leite, H.
Carvalho, A.
Powiązania:
https://bibliotekanauki.pl/articles/136202.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
DC circuit breaker
HVDC
Protection Device
voltage source converter (VSC)
Short-circuit
Opis:
Protection issue is identified as the main drawback of emerging multi-terminal HVDC grids. Multi-terminal HVDC grid demands fast short circuit fault current interruption. Fast DC circuit breakers as a promising solution can be implemented as either bidirectional or unidirectional devices. In addition to less implementation cost, the unidirectional DC circuit breakers have less power losses as compared to the bidirectional devices. A protection strategy for multi-terminal HVDC grid based on unidirectional breaking devices is discussed and assessed in this paper. The performance of unidirectional protection strategy is examined under different fault scenarios in a fourterminal MMC-HVDC grid model. Furthermore, the impacts of unidirectional protection strategy on power converters and also current interruption and surge arrester ratings of the DC circuit breakers are discussed.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 58-65
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analogowo-cyfrowy rejestrator szybkich obiektów
Autorzy:
Madej, W.
Powiązania:
https://bibliotekanauki.pl/articles/118329.pdf
Data publikacji:
2014
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
układy analogowo-cyfrowe
filtracja analogowa
filtracja cyfrowa
układ dopasowujący
algorytm
analog-to-digital circuit
analog filtering
digital filtering
matching circuit
algorithm
Opis:
W pracy przedstawiono praktyczną realizację analogowo-cyfrowego systemu rejestracji szybkich obiektów. Przez szybkie obiekty rozumie się przeciwlotnicze pociski artyleryjskie o kalibrach powyżej 23 mm. System został zbudowany z wykorzystaniem stacji radiolokacyjnej ZRP-1 „WAZA” oraz sprzężonego z nią komputera klasy IBMPC wyposażonego w kartę wejść – wyjść analogowych. Przedstawiono część analogową systemu oraz algorytm obliczeń realizowanych w komputerze traktowany jako cyfrową obróbkę sygnałów. Na koniec omówiono wizualizację wyników rejestracji. System ten był już wielokrotnie wykorzystywany podczas badań nowych przeciwlotniczych zestawów artyleryjskich.
In this work practical realization of the analog to digital recording system of the fast object are presented. As a fast object the anti-aircraft artillery guns whit caliber 23 mm or greater are understanding. The system was build with use of the radar station ZRP-1 “WAZA” coupling with computer IBMPC appointed an analog inputoutput adapter. The analogue section and the algorithm of the computation realizing in the computer, treating as digital data processing, are presented. At last visualisation of the recording results are discuss. Presented system was repeatedly used during a new anti-aircraft artillery systems research.
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2014, 6; 15-23
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lighting device parameters influence on signal circuit safety in interlocking systems
Autorzy:
Nagy, P.
Ždánsky, J.
Powiązania:
https://bibliotekanauki.pl/articles/393479.pdf
Data publikacji:
2010
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
bezpieczeństwo układu
SRK
semafor świetlny
interlocking system
signal circuit safety
colour light signal
Opis:
Signal circuits are an important part of the interlocking system. The main role of the signalling circuit is to switch the required signal aspects and signal checking. A signal is an interface between the interlocking system and a driver of the railway vehicle. Light bulbs are mostly used as a light source in most types of interlocking systems. It is possible to think about alternative light sources within the context of modernisation of the interlocking systems. The use of alternative light sources using must not cause signal circuit safety degradation. The article deals with problems of light bulbs replacement for another light source in AŽD 71 type relay interlocking in the Railways of Slovak Republic.
Źródło:
Archives of Transport System Telematics; 2010, 3, 3; 9-13
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Implementation of the Parallel Scrambler Scheme for the IEEE 802.11 Standard
Autorzy:
Kudinov, A.
Antimirov, Y.
Tyshchenko, I.
Popova, M.
Cherepanov, A.
Powiązania:
https://bibliotekanauki.pl/articles/226358.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
scrambler
sequential circuit
parallel circuit
Opis:
This article is devoted to the development of the scrambler circuit. Nowadays, new WiFi standard IEEE 802.11 is being put into operation, so that there is a huge need in modern, energy-efficient algorithms, which will be used in the data transmission. Consequently, some of the scrambler circuits, which could be implemented for the IEEE 802.11 standard are described with its comparison. In addition, an example in Python is given for readers to use it in their researches.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 1; 91-94
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies