Wyszukujesz frazę "transients" wg kryterium: Wszystkie pola


Wyświetlanie 1-70 z 70
Tytuł:
The modeling of centrifugal pump transients
Autorzy:
Szymczyk, J.
Karaśkiewicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/175255.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
rotodynamic pumps
complete pump characteristics
transients
Opis:
Centrifugal pumps are part of larger hydraulic systems. These hydraulic machines can work not only in the pumping mode but in a number of other modes whose job description is possible using complete characteristics. Some of these modes, such as the turbine mode and the reversed turbine mode, may have practical significance. Knowledge of the transition from one steady state to another state allows to estimate instantaneous values such as, e.g., flow current and torque, which may be even a few times higher than nominal. The principal issues in these transients are amplitudes of parameters of these pumps and the time constants associated with the characteristics of the system.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 130; 83-92
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved method for simulating transients of turbulent pipe flow
Autorzy:
Zarzycki, Z.
Kudźma, S.
Urbanowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/280935.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
unsteady pipe flow
transients
waterhammer
efficient numerical simulation
Opis:
The paper presents the problem of modelling and simulation of transients during turbulent fluid flow in hydraulic pipes. The instantaneous wall shear stress on a pipe wall is presented in the form of integral convolution of a weighting function and local acceleration of the liquid. This weighting function depends on the dimensionless time and Reynolds number. Its original, very complicated mathematical structure is approximated to a simpler form which is useful for practical engineering calculations. The paper presents an efficient way to solve the integral convolution based on the method given by Trikha (1975) for laminar flow. An application of an improved method with the use of the Method of Characteristic for the case of unsteady flow (water hammer) is presented. This method is characterised by high efficiency compared to traditional numerical schemes.
Artykuł przedstawia zagadnienie modelowania i symulacji przebiegów przejściowych podczas turbulentnego przepływu cieczy w przewodach ciśnieniowych. Chwilowe naprężenie styczne na ściance przewodu przedstawiono w postaci całki splotowej z funkcji wagi i przyspieszenia cieczy. Funkcja wagi dla naprężenia stycznego na ściance przewodu zależy od czasu bezwymiarowego i liczby Reynoldsa. Ma ona zawiłą postać matematyczną, dlatego aproksymowano ją do prostszej postaci, przydatnej do praktycznych obliczeń inżynierskich. Przedstawiono efektywny sposób rozwiązania całki splotowej, opierając się na metodzie podanej przez Trikha (1975) dla przepływu laminarnego. Podano zastosowanie ulepszonej metody symulacji naprężenia stycznego do metody charakterystyk podczas uderzenia hydraulicznego. Charakteryzuje się ona dużą efektywnością w stosunku do metody tradycyjnej.
Źródło:
Journal of Theoretical and Applied Mechanics; 2011, 49, 1; 135-158
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of transformer modeling on riser pole arresters behavior during switching transients
Autorzy:
Abbaszadeh, A.
Abedi, M.
Doustmohammadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/140474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arresters
ATP software
ferroresonance
transformer
power system transients
Opis:
Arresters are widely used in power systems to protect other equipment against overvoltages. However, in some conditions, they can’t operate successfully. One of the disturbances leading to the failure of the riser pole arresters is the ferroresonance overvoltages. In this paper, at first the influence of different transformer simulation models of ATP software on the occurrence of ferroresonance is studied and then the effect of ferroresonance on the riser pole arrester has been scrutinized through the thermal and electrical performance of the arrester in an underground distribution system. The results show that the arrester temperature rises due to energy dissipation in a ferroresonance circumstance, which indeed may result into the explosion of the arrester. Also, applying different models of the transformer in the ATP software and comparing the results, it is shown that the available models do not show the same effect on the arrester.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 717-730
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling transients in MV resonantly grounded industrial grid during single line to ground faults
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/377060.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical grid
grounding methods
transients overvoltage
transient intermittent faults
Opis:
Medium voltage distribution power grids mostly operate with ungrounded neutral points of transformer. The philosophy about these power supply systems based on the assumption that the electrical grid is more reliable. However the practice of operation showed that currents of single phase or multiple faults to ground depend mostly on the earth capacitances of cables connected to power grid and configuration and structure in relation to the main substation buses. Moreover, this kind of arcing ground faults on the ungrounded system causes transient overvoltages several times than nominal value. In the consequence, it may be dangerous for the electrical devices connected to the power system. The article focuses on the transient impact the equipment insulation due to faults in the middle voltage industrial grid with adjustable speed drives. The examination results of transient voltages across the system was presented. The Matlab/ Simulink Software was used to modeling system behavior during intermittent faults.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 98; 65-75
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Hydraulic Characteristics on Fluid Transients Analysis under Different Types of Control Valves
Autorzy:
Al-Zaidi, Basim M.
Ismaeel, Abaas J.
Powiązania:
https://bibliotekanauki.pl/articles/2202314.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hydraulic characteristics
fluid transients
valve
Opis:
In this study, several types of valves were used to study the impact of the valves types and closure characteristics on fluid transients. The valve closure curves, which are the variation of the effective valve opening as a function of percentage opening area, were derived for different selected valves. Six different types of valves were selected to study the effect of the valves types on fluid transient conditions. For simplification, a very simple pipeline system was assumed and presented in this study. The system is about two pipes connected in a series junction and they take the water from a constant-level reservoir at upstream and a valve at downstream. The duration of valve closure was taken as six seconds which plays an important role in the pressure development in the system. A method of characteristics is applied to compute the transient conditions under gradual closure of the valves. Valve data of various forms were compiled and reported as discharge and headloss coefficients as a function of valve opening. The effect of valve geometry and operation on the relative valve opening were compared. Discharge and headloss coefficients were also compared between valve types. The study concluded that transient conditions depend on the valve type. The comparison between the results of all valve types indicated that the changes in pressure and discharges depend on valve type where there is a difference in effective valve opening. It can be concluded that the valve with the highest value of valve effective opening has less effect on transient conditions, i.e., the faster changes of effective valve opening the larger the effect on transient conditions (discharge and the greater the magnitude of the pressure wave). This study would help to select the property valve in pipeline design.
Źródło:
Journal of Ecological Engineering; 2022, 23, 12; 111--123
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydraulic transients analysis in pipe networks by the method of characteristics (MOC)
Autorzy:
Wichowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/240954.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
hydraulic transients
method of characteristics
single pipe
experimental measurement
pipe networks
numerical simulations
Opis:
The paper presents results of an experimental and theoretical study of the hydraulic transients in straight pipes and numerical simulations of unsteady flow in pipe networks. A mathematical model consists of a set of partial differential equations of hyperbolic type, which have been transformed by the method of characteristics into ordinary differential equations which are solved by the predictor-corrector method. Experimental tests have been performed, in order to examine the hydraulic transients phenomenon, in a single straight steel pipe. The experiments were carried out in the hydraulic laboratory of the Institute of Water Supply and Water Engineering, Environmental Engineering Faculty, Warsaw University of Technology. The numerical results show that the presented one dimensional model for a single pipe correctly describes the phenomenon since there is a good agreement with experimental maximum and minimum oscillations. In the paper, selected exemplary equations in a difference form for the pipe networks are also presented. One calculation example is given relating to the complex water-pipe network consisting of 17 loops, 48 pipelines and 33 nodes, supplied by two independent sources. Water-hammer throughout the whole pipeline network was caused by closing the gate valve at mid-point of one selected pipe. The results of the numerical calculations are presented in graphic form with respect to the final cross-sections of pipes.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2006, 53, 3; 267-291
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients under energizing multiple power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97327.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
C–type filter
Static Var Compensator
transient overcurrent
transient overvoltage
dynamic overcurrent
dynamic overvoltage
switching transients
Opis:
The practice of operating reactive power compensation systems involving passive multiple filter circuits (FC) configured by single–tuned filters has shown, that it’s energizing can cause damage of the filter components. Impact of feasible FC configurations, including FC with a C–type filter, on switching overvoltages and overcurrents under the harmonic filters energizing were analyzed. Influence of the filters tuning on transient behavior has been shown. The transient analysis has been carried out by simulating of the FC within Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 89-100
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients in Transformers with Non-Uniform Inductance and Capacitance Distributions
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262695.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
distributed parameter circuits
electromagnetic transients
integro-differential equations
modeling
mutual parameters
non-uniform
power transformers
transient response
winding
Opis:
The electromagnetic transients in transformer windings exhibiting location–dependent inductances and capacitances are investigated in the time domain. Analytical functions describing this dependence are assumed and incorporated in the two integro–differential equations governing the transient voltage and current distributions. The boundary conditions are available from the source initiating the transients and the winding’s end termination. A numerical procedure is applied in order to get frequency domain solutions for the voltage and current in the form of Interpolating and Parametric Functions. The numerical Laplace inversion is then applied to these s–domain expressions. Results pertinent to transients initiated by step- and double-exponential impulse sources are presented and discussed. All possible transformers’ neutral connections are considered. The possible error introduced by neglecting either or both of the inductance and capacitance non-uniformities is addressed. Results indicate that the main error is attributed to neglecting the inductance non-uniformity, whereas the impact of the capacitance non-uniformity is relatively small. In most cases, the winding’s copper and insulation losses have a small effect on the transient response.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2017, 20, 1; 7-14
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical criterion for the duration of non-chaotic transients in ODEs
Autorzy:
Szczebiot, Ryszard
Kaczyński, Roman
Gołdyn, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/2204683.pdf
Data publikacji:
2022
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
numerical criterion
non-chaotic transients
limit cycle
ODEs systems
Van der Pol oscillator
Opis:
The paper proposes an original numerical criterion for the duration analysis of non-chaotic transients based on the Euclidean norm of a properly defined vector. For this purpose, transient trajectories, prior to their entering a small neighbourhood of the limit cycle, are used. The vector has been defined with its components constituting the lengths of the sections, which connect the origin of the coordinate system with appropriately determined transient trajectory points. The norm of the vector for the analysis of non-chaotic transients has also been applied. As an assessment criterion of transients, the convergence of the norm to small neighbourhood of the limit cycle with the assumed accuracy is used. The paper also provides examples of the application of this criterion to the Van der Pol oscillators in the case of periodic oscillations.
Źródło:
Acta Mechanica et Automatica; 2022, 16, 4; 388--392
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Low Frequency Transients in Power Transformers and Some Protection-Related Issues
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/1203944.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
transformer cores
inrush current
protection
transients
modeling
equivalent circuit
low frequency
nonlinear model
simulation
Opis:
This paper presents typical results for the non-linear low frequency transients following the energization of power transformers. The three operating conditions of no-load, full-load and internal faults are considered. A direct analytical procedure is applied for solving the corresponding set of differential equations describing the transformers equivalent circuit. The core representation is based on the use of curve fitting applied to their magnetization curves. The results include plots versus time for the supply current, the core flux, the magnetizing current as well as the internal induced voltage. Moreover, graphs for the hysteresis loops relating the instantaneous values of both the excitation current and the core flux are given. An approach is also presented for the numerical determination of the amplitudes of the different harmonics existing in any of these signals utilizing the corresponding equidistant samples. As examples, the DC offset as well as harmonics up to the fourth order are considered. It is shown that several useful features can be extracted from the results in both the time and harmonic domains that can assist in differentiating between overcurrents resulting from short-circuits or inrush phenomena.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2014, 17, 2; 9-16
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Transients in a 4-Level Flying Capacitor Converter: Time Domain Approach. Part 2: Small Normalised Voltage Command
Autorzy:
Reznikov, Boris
Ruderman, Alex
Galanina, Valentina
Powiązania:
https://bibliotekanauki.pl/articles/1193863.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
4-level DC–DC converter
flying capacitor
natural balancing
transients
Opis:
A 4-level flying capacitor converter (FCC) operation is considered on a base of discrete state-space model. A transition matrix is obtained for a pulse width modulation (PWM) period for small normalised voltage command values [0, 1/3]. The transition matrix elements are expanded into power series by small parameters. The matrix eigenvalues are presented in the form of power series as well. Six separate transients are constructed for six possible initial FCC states on a PWM period. Inductor current and capacitors’ voltage transients are found for the voltage source power-up as the arithmetic average of the six separate transients. Finally, the discrete solutions are replaced by equivalent continuous ones. Simple and accurate formulas for inductor current and capacitors’ voltage transients demonstrate good agreement with simulation results.
Źródło:
Power Electronics and Drives; 2020, 5, 40; 41-57
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Transients in a 4-Level Flying Capacitor Converter: Time Domain Approach. Part 1: Large Normalised Voltage Command
Autorzy:
Reznikov, Boris
Ruderman, Alex
Galanina, Valentina
Powiązania:
https://bibliotekanauki.pl/articles/1193906.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
4-level DC-DC converter
flying capacitor
natural balancing
transients
Opis:
A 4-level flying capacitor converter (FCC) operation is considered on a base of discrete state-space model. A transition matrix is obtained for a pulse width modulation (PWM) period for large normalised voltage command values [1/3, 1). The transition matrix elements are expanded into power series by small parameters. The matrix eigenvalues are presented in the form of power series as well. Six separate transients are constructed for six possible initial FCC states on a PWM period. Inductor current and capacitors’ voltage transients are found for the voltage source power-up as the arithmetic average of the six separate transients. Finally, the discrete solutions are replaced by equivalent continuous ones. Simple and accurate formulas for inductor current and capacitors’ voltage transients demonstrate good agreement with simulation results.
Źródło:
Power Electronics and Drives; 2020, 5, 40; 27-40
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vibration transients of reservoir-pipe-valve system caused by water hammer
Autorzy:
Miao, Yang
Jiang, Yuncheng
Qiu, Zaihui
Pan, Jun
Wang, Lu
Han, Zhenrong
Li, Kun
Zhang, Li
Zhang, Xiaolu
Powiązania:
https://bibliotekanauki.pl/articles/1839616.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
reservoir-pipe-valve system (RPV system)
water hammer
vibration
transients
Opis:
A severe oscillation, accompanied with an abnormal “click” sound, of a fuel feeding pipe system during valve closing, when the feeding flowrate reaches a certain value, is observed experimentally. A fluctuation model in which stiffness and damping coefficients of the vibration system are time varying is proposed. Each coefficient is composed of two parts, one of which is constant and the other is time varying. Based on this model, simulation transients of the vibration displacement, velocity and pressure in the pipe are presented. Simulations of the pressure transients are compared with experimental data detected by pressure transducer, which shows that both have fluctuations in the transient process at a large flowrate.
Źródło:
Journal of Theoretical and Applied Mechanics; 2020, 58, 4; 1037-1048
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of IGCT turn-on transients in circuit configurations with series connected diodes
Autorzy:
Tschirley, S.
Bernet, S.
Powiązania:
https://bibliotekanauki.pl/articles/262745.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Opis:
This paper describes the effect of series connected diodes and their balancing networks m the clamp circuit in IGCT converters. It is shown, that the balancing of the clamp diodes has other requirements than the balancing of the series connected freewheeling diodes in the switch cell. The dynamic and static balancing of the clamp diodes is analyzed in detail.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 33-39
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Double Injection Current Transients in a-Si:H
Autorzy:
Nekrašas, N.
Genevičius, K.
Juška, G.
Powiązania:
https://bibliotekanauki.pl/articles/1813197.pdf
Data publikacji:
2008-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
73.50.Gr
Opis:
In this work we present results of both computer modelling and experimental studies of double injection current transients in amorphous hydrogenated silicon thin layers.
Źródło:
Acta Physica Polonica A; 2008, 113, 3; 845-849
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long lasting transients in power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97714.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inrush current
arc fumace transformer
harmonic filter
switching transient
Opis:
The practice of operating AC electrical arc fumace power supply systems has shown that energizing unloaded fumace transformer can cause long lasting transients in filter circuits of static VAR compensators used in the supply systems. Examination of the supply system configuration impact on switching transient behaviour has been carried out by example of a 50 MVA arc fumace unit. The transient analysis has been carried out through simulating by Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 324-333
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Output characteristics of step-down (Buck) power converter
Autorzy:
Janke, W.
Bączek, M.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/201669.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC-DC converters
output characteristics
load transients
Opis:
The output characteristics of switched-mode dc-dc buck power converter are discussed. The shape of output characteristics is especially important for converters used for supplying modern processors. An output impedance is usually used for description of output characteristics. Many efforts are described in the literature to obtain the satisfastory features of closed-loop output impedance. Another approach, presented in the paper, is based on the concept of the output voltage response corresponding to the load conductance change, and is expressed by hr transmittance. Simulations of output characteristics of the buck converter in frequency and in time-domain have been performed for the ideal case as well as for a more realistic situation, with the parasitic resistances of converter elements included. The measurement results differ substantially from characteristics calculated for an ideal converter and are in good consistency with simulations including parasitics.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 4; 751-755
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of the magnetostrictive actuator transients
Autorzy:
Idziak, P.
Kowalski, K.
Nowak, L.
Barlak, M.
Pochrybniak, C.
Powiązania:
https://bibliotekanauki.pl/articles/377166.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
actuators
magnetostriction
electromagnetic field
transient analysis
Opis:
The paper deals with a magnetostrictive fast-acting actuator applied as a driving device for plasma valve. The actuator is characterized by a relatively small displacement (les then 0.1 mm), but with a very short response time – below 0.1 ms. System is designed for so called “high intensity plasma pulses gun” which is applied in the area of plasma physics and material engineering [1]. A structure with an axisymmetrical actuator energised by discharged pulses of a capacitor has been proposed. The field-circuit mathematical model of the dynamic operation of the actuator has been applied. The model includes: the equation of transient electromagnetic field in a non-linear ferromagnetic material and equation of electric circuit. Using the Borland Delphi 9.0 environment, the computer software has been elaborated. Results of simulation are presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 83; 23-30
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of different methods for excitation of synchronous machines
Autorzy:
Schmuelling, S.
Kreischer, Ch.
Gołȩbiowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1367718.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
AC machines
Brushless machines
Electromagnetic transients
Excitation system
Power system simulation
Opis:
The energy turnaround in Germany leads to new operating conditions for small and medium synchronous generators. Since the electricity generation through renewable energy sources, such as wind or photovoltaic, is highly volatile, generators have to run up from standstill into rated operation within several minutes. Hence, it is necessary to compensate a lack of electricity generation caused by wrong weather forecasts. Usually, gas turbine systems provide this possibility. The generator is used as a starter engine due to the connection to a frequency inverter. The excitation current is often provided by static excitation systems. Thus, it is possible to start from standstill and run up the drive until the gas turbine is able to generate a positive torque. A new excitation concept, based on an induction machine with a 3-phase rotor winding, is able to provide an excitation current at 0 rpm and eliminates the need for brushes. To verify the applicability for power systems, both systems are compared under different aspects. The control of the excitation current at different speeds and the possibility to settle shaft oscillations after electrical faults are aspects researched in the paper at hand. A power system simulation is performed with a synchronous machine connected to a grid. Both excitation systems are modeled by equivalent circuit diagrams in Matlab Simscape.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 89-93
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accidents of loss of flow for the ETTR-2 reactor: deterministic analysis
Autorzy:
El-Messiry, M.
Powiązania:
https://bibliotekanauki.pl/articles/146728.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
design base accidents
LOFA
loss of flow
pump coastdown
reactor transients
Opis:
The main objective for reactor safety is to keep the fuel in a thermally safe condition with adequate safety margins during all operational modes (normal-abnormal and accidental states). To achieve this purpose an accident analysis of different design base accident (DBA) as loss of flow accident (LOFA), is required for assessing reactor safety. The present work concerns this transients applied to Egypt Test and Research Reactor ETRR-2 (new reactor). An accident analysis code FLOWTR is developed to investigate the thermal behaviour of the core during such flow transients. The active core is simulated by two channels: 1 - hot channel (HC), and 2 - average channel (AC) representing the remainder of the core. Each channel is divided into four axial sections. The external loop, core plene, and core chimney are simulated by different dynamic lumps. The code includes modules for pump coast down, flow regimes, decay heat, temperature distributions, and feedback coefficients. FLOWTR is verified against results from RETRAN code, THERMIC code and commissioning tests for null transient case. The comparison shows a good agreement. The study indicates that for LOFA transients, provided the scram system is available, the core is shutdown safely by low flow signal (496.6 kg/s) at 1.4 s where the HC temperature reaches the maximum value of 45.64°C after shutdown. On the other hand, if the scram system is unavailable, and at t=47.33 s, the core flow decreases to 67.41 kg/s, the HC temperature increases to 164.02°C, and the HC clad surface heat flux exceeds its critical value of 400.00 W/cm2 resulting from the fuel burnout.
Źródło:
Nukleonika; 2000, 45, 4; 229-233
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients impact on power filter circuit sizing
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97523.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
transient and dynamic overvoltage
transient and dynamic overcurrent
equipment ratings
Opis:
The practice of operating multiple single-tuned filters in AC electrical arc furnace power supply systems has shown, that frequent energizing unloaded furnace transformer can cause damage of the filters. To examination of supply and filter system configuration impact on switching transient and dynamic overvoltages and overcurrents, an example of 50 MVA arc furnace unit was chosen. The transient analysis has been carried out by simulating within Matlab/Simulink Software. Using ANSI/IEEE Standards paper focuses on the selections of ratings for capacitors and air-core reactors used in multiple single-tuned harmonic filters configurations. Comparison of filter reactor and capacitor bank design based on steady state operation and transformer energizing was shown.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 111-119
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parks Transformation Based Formulation For Power Systems Transients Detection
Autorzy:
Ferraz, R. G.
Iurinic, L. U.
Filomena, A. D.
Bretas, A. S.
Powiązania:
https://bibliotekanauki.pl/articles/410529.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Park's transformation
transient detection
power systems
Opis:
This paper presents proposed developments of a new formulation and a full algorithm for transient detection by applying Parks transformation. This approach consist in transforming three-phase voltage or current signals into Parks components known as direct, quadrature, and zero axes components. The input signals are local measurements of a power transmission or distribution system. Then, transients are superimposed in three-phase signals that can be detected in Parks components through the finite difference between samples. A full algorithm for the transient detection is presented and envisions the possibility of being applied in real time. In order to demonstrate the proposed algorithms performance, four case studies are considered: capacitor energizing, distribution transformer energizing, permanent resistive fault, and high impedance fault. These cases were simulated on a typical Brazilian sub-transmission line using Alternative Transient Program. As demonstrated by the case studies, the proposed formulation introduces further improvements for transient detection in power systems.
Źródło:
Present Problems of Power System Control; 2013, 4; 5-23
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obrazowanie termiczne stanów przejściowych przy załączaniu tyrystora
Thermal imaging of thyristor turn-on transients
Autorzy:
Kałuża, M.
Napiórkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/154464.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
przyrządy półprzewodnikowe mocy
thermovision
power semiconductor devices
Opis:
W artykule przedstawiono wyniki badań dotyczące możliwości zastosowania kamery termowizyjnej do rejestracji termogramów szybkich procesów przejściowych generacji ciepła w czasie załączania otwartej struktury półprzewodnikowej tyrystora. Badania wykazały możliwość rejestracji termogramów w czasie załączania przyrządu półprzewodnikowego mocy przy odpowiednim doborze niestandardowych ustawień pracy kamery termowizyjnej.
The paper presents the results of investigations on possible use of a thermal imaging camera for the recording of fast transient processes of heat generation during the switching of semiconductor structures in semiconductor power devices, based on measurements of a thyristor semiconductor structure. Using a measurement setup consisting of an IR camera and of a purpose build current pulse generator, the thermal behaviour of the T00-80 thyristor semiconductor structure during turn on was investigated. The thermograms were recorded at speeds reaching 1400 frames per second. Studies of the semiconductor structure of the thyristor mounted in a special holder showed the possibility of using a thermal camera for analyzing the behaviour of power semiconductor devices, however further increase in the temporal resolution of the recording process will be needed. One of the solutions will be to synchronize operation of a pulse generator and a thermal camera, including a controlled, variable time delay between current pulse generation and image acquisition.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1199-1201
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określanie charakterystyk drganiowych silników turbinowych w stanach nieustalonych
Determining vibration characteristics in marine turbine engines in transients conditions
Autorzy:
Grządziela, A.
Powiązania:
https://bibliotekanauki.pl/articles/223192.pdf
Data publikacji:
2011
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
silnik turbinowy
charakterystyki
drgania
turbine engine
characteristics
vibrations
Opis:
W artykule przedstawiono metodę wyznaczania charakterystyk drganiowych okrętowych turbinowych silników spalinowych. Zaproponowano sposób akwizycji danych z pomiarów w stanach nieustalonych oraz metodykę badań procesów drganiowych zachodzących w procesach zimnego i gorącego rozruchu oraz wybiegu wirnika wytwornicy spalin.
The paper presents a method for determining vibration characteristics in marine turbine engines. It proposes a way of data acquisition from measurements in transient conditions, as well as methodology for investigating vibration processes occurring under run-up and shut-down engine processes and rotor coasting of gas generator.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2011, R. 52 nr 3 (186), 3 (186); 57-64
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the Interaction Between Theory, Experiments, and Simulation in Developing Practical Learning Control Algorithms
Autorzy:
Longman, R. W.
Powiązania:
https://bibliotekanauki.pl/articles/908249.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
automatyka
robotyka
iterative learning control
ILC
2D systems
learning transients
Opis:
Iterative learning control (ILC) develops controllers that iteratively adjust the command to a feedback control system in order to converge to zero tracking error following a specific desired trajectory. Unlike optimal control and other control methods, the iterations are made using the real world in place of a computer model. If desired, the learning process can be conducted both in the time domain during each iteration and in repetitions, making ILC a 2D system. Because ILC iterates with the real world, and aims for zero error, the field pushes the limits of theory, modeling, and simulation, to predict the behavior when applied in the real world. It is the thesis of this paper that in order to make significant progress in this field it is essential that the research effort employ a coordinated simultaneous synergistic effort involving theory, experiments, and serious simulations. Otherwise, one very easily expends effort on something that seems fundamental from the theoretical perspective, but in fact has very little relevance to the performance in real world applications.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2003, 13, 1; 101-111
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on ferroresonance due to power transformer energization in high voltage 400 kV transmission grid
Autorzy:
Polewaczyk, Mateusz
Robak, Sylwester
Szewczyk, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/141509.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ferroresonance
high voltage
Poincaré map
power system transients
PSCAD
Opis:
This paper presents a study on ferroresonance occurring in a high voltage 400 kV transmission grid due to energization of power transformer under no-load conditions. The system scenarios analyzed in the present paper are considered as critical for development and modernization plans as currently announced by the national grid operator in Poland. The PSCAD simulation model was developed and applied for several study cases of a system with double-circuit arrangement of a transmission line. It is shown that the ferroresonant oscillations can be initiated by two-phase switching operation of a line circuit breaker. The impact of the double-circuit length on the ferroresonance mode and severity is demonstrated with the use of the Poincaré map analysis and Short Time Fourier Transform. It is demonstrated that the length of the transmission line that is mutually coupled in the double-circuit arrangement has a significant impact on the ferroresonance occurrence and on its mode. As the ferroresonance can pose severe threat to the power system components due to the severe overvoltage and overcurrent oscillations, the analysis presented in this paper demonstrates the necessity of the ferroresonance analyses for any re-designed transmission system.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 771-786
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined monitoring and time-frequency analysis for transients in wind energy systems
Autorzy:
Łobos, T.
Sikorski, T.
Amarís, H
Alonso, M
Florez, D
Powiązania:
https://bibliotekanauki.pl/articles/1395766.pdf
Data publikacji:
2010
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power quality monitoring
wind energy
wind power plant
Opis:
The aim of this paper is the application of selected time-varying power quality indices combined with detailed time-frequency analysis for assessment of transients in wind energy system. Presented proposition utilizes short-term harmonic distortion in voltage (STHDV) characteristic as an indicator for detail local time-frequency analysis of the transients. Introduced ideas can be treated as hybrid system absorbing both power quality indices and time-frequency representation.
Źródło:
Computer Applications in Electrical Engineering; 2010, 8; 261-269
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical calculations of surges caused by direct lightning strike to underground intrusion detection system
Autorzy:
Aniserowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/200287.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lightning
transients
overvoltages
analytical modeling
underground cable
błyskawica
transjenty
przepięcia
modelowanie analityczne
kabel podziemny
Opis:
The paper presents an analysis of overvoltages caused by a direct lightning strike in intrusion detection system equipped with underground radiating cable sensors. Waveforms of currents and voltages in the system components are calculated using analytical formulas basing on a transmission-line model in the frequency domain. The time-domain waveforms are computed using the inverse fast Fourier transform (IFFT). Three network configurations of the intrusion detection system are analyzed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 2; 263-270
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of synchronous generators for the analysis of frequency transients above 1 Hz/s
Autorzy:
Assenkamp, Alf
Powiązania:
https://bibliotekanauki.pl/articles/2135729.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control system
distributed energy systems
frequency support
generator model
RoCoF
synchronous generators
synchronous machines
Opis:
Large synchronous generators are of high importance for the stability of power systems. They generate the frequency of the system and stabilize it in case of severe grid faults like trips of large in-feeders or loads. In distributed energy systems, in-feed via inverters will replace this generation in large parts. Modern inverters are capable of supporting grid frequency during severe faults by different means on the one hand. On the other hand, higher Rates of Change of Frequency (RoCoF) after incidents need to be accustomed by future systems. To be able to analyse the RoCoF withstand capability of synchronous or induction generators, suitable models need to be developed. Especially the control and excitation system model need enhancements compared to models proposed in standards like IEEE Std 421.5. This paper elaborates on the necessary modelling depth and validates the approach with example results.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 687--700
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Transients in a Three-Level DC–DC Flying Capacitor Converter. Time Domain Approach
Autorzy:
Reznikov, Boris
Ruderman, Alexander
Galanina, Valentina
Powiązania:
https://bibliotekanauki.pl/articles/1193695.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
three-level DC–DC converter
flying capacitor
transient
natural balancing
Opis:
The paper considers a discrete state-space model for transients in a three-level flying capacitor DC–DC converter. A transition matrix is obtained for a pulse width modulation (PWM) period. The matrix elements are expanded into a power series using a selected small parameter. The matrix eigenvalues that determine the natural balancing dynamics transients are presented in the form of power series as well. Four separate transients are constructed based on four possible PWM period initial states (topologies). Inductor current and capacitor voltage transients are found for the voltage source power-up as the arithmetic average of the four separate transients. The discrete solutions are replaced by continuous ones. The resulting transients that are elementary functions of the circuit parameters, PWM period, and voltage reference demonstrate good agreement with the simulation results.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 33-45
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fuel feed to diesel at a start regime
Autorzy:
Fedyanov, E.
Slavuckiy, V.
Kanygin, Z.
Powiązania:
https://bibliotekanauki.pl/articles/246126.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
starting duty
features of process of giving
nozzle valve lifting
injection pressure
transients
cyclic fuel delivery
Opis:
Some factors defining starting properties of diesel engines are considered. Features of process of fuel feed on a starting mode are analyzed. Basic possibility of steering by processes of mixture forming and combustion is proved at a small speed of a crankshaft. Developed a design procedure of process of fuel feed in a diesel engine at a start regime. On the basis of the theory of transients in a fuel system, the reasons of deterioration of indicators of fuel feed process are explained at a start regime of diesel engine. Possibilities of a method of increase of initial pressure in a delivery highway by prostrating scrolling of a crankshaft with idle spray jets are investigated. The method of intensification of fuel feed process patented by authors used in diesel engine at a start regime. The results of numerical experiments confirming improvement of indicators of process of injection at high-speed speeding up of the pump of a high pressure are resulted: Increase maximum and an average pressure, cutting-down of duration of fuel feed process. The paper concentrates on possibility of improving fuel fed process at the starting regime by means of high speed forcing the fuel pump and the initial pressure rising by an earlier camshaft rotation with out of work injectors.
Źródło:
Journal of KONES; 2009, 16, 1; 111-116
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of transients in multiple power filter circuit comprising C-type filter
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/377600.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
C–type filter
single-tuned passive filter
switching transient
transient overvoltage
transient overcurrent
Opis:
Passive filters are widely used to mitigate the effect of load harmonics on the supply power grid. Topology selection of the filters is based on the frequency bandwidth to be suppressed. Filter topologies comprising single-tuned filters and damped filters are the most popular in industrial power system applications. The article focuses on the influence of the damped C-type 2nd harmonic filter on the transients behavior under arc transformer energization in the arc furnace power supply system compensated by SVC. The examination results of transient currents and voltages across capacitors and reactors of the 3rd and 5th passive filters are compared for two topologies of the SVC filter circuits: with and without C-type filter. The Matlab/Simulink Software was used to modeling filter behavior during unload transformer switching-on.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 95; 105-115
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics simulations of the electrodynamic railgun different constructions and their measurement verification
Autorzy:
Piekielny, Paweł
Tomczuk, Bronisław
Waindok, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/27309948.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
3D field analysis
analysis of transients
analytical models
electrodynamic accelerator
experimental verification
field-circuit modeling
projectile velocity
Opis:
Dynamic characteristics for three types of railgun constructions were simulated and measured in this work. The simplest construction is the iron-less (IL) railgun, while the two other ones (IC and ICPM) have an iron-core. The iron-core permanent magnet (ICPM) railgun additionally has permanent magnets. To compare their characteristics, similar dimensions of the rails and iron cores were adopted, and the same power supply system was used. Numerical magnetic field analyses and our analytical models have been used to determine the electromagnetic parameters. They were verified experimentally. The transient states of the railguns were studied with our field-circuit mathematical model, and their results were also verified by experiments.
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 951--969
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulations of Fast Transients in typical 25 kV a.c. railway power supply system
Symulacje stanów nieustalonych w typowym 25 kV a.c.układzie zasilania trakcji
Autorzy:
Chmielewski, T.
Dziadkowiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/266311.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
railway
lightning
PSCAD
trakcja
przepięcia piorunowe
Opis:
Railway power lines as any other outdoor overhead conductors are exposed to lightning strokes. Overvoltages generated by a lightning surge may severely decrease the overall system reliability due to possible damages of powering and signalling equipment. Hence an appropriate design of lightning protection is crucial. This paper presents computer simulations of lightning phenomenon (Fast Transients) in a typical railway catenary system conducted in PSCAD software. Detailed numerical model consisted of cables, overhead catenary lines, surge arresters, transformers and rails. A few modelling approaches were used and compared. The outcome of such analysis can be helpful in determining possible overvoltages in railway system along with a proposal of ratings and locations of additional surge arresters’ installation.
Treść artykułu skupia się na symulacyjnych badaniach przepięć piorunowych w sieci zasilania trakcji elektrycznej. W oparciu o model typowego systemu 25 kV a.c., przeprowadzono porównanie odpowiedzi układu w przypadku zmiany podejścia do modelowania elementów takich jak napowietrzna sieć trakcyjna, czy też szyny.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 36; 43-46
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transformer Modelling for the Frequency and Transient Analyses, with Non-Uniform Inductance Emulating the Inter-Turn Magnetic Coupling
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262677.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
distributed parameter circuits
frequency response
modeling
power system transients
power transformers
resonance
non-uniform
Opis:
A new procedure for analyzing power transformer windings with location-dependent circuit parameters, such as the series inductance, is presented. This dependence is introduced in order to take the inter-turn mutual inductive coupling into consideration. It can be expressed either by analytical expressions or even in a tabulated form. The paper addresses both the frequency and time domain analyses. They are based on replacing the winding by an adequate number of equivalent cascade connected two-ports. In contrast to the usual practice of applying the simple medium line representation, each of these two-ports is treated as a long transmission line. Their A, B, C, D generalized circuit constants will be therefore generally location-and frequency-dependent. The analyses will be conducted in the complex s-domain. The corresponding time-domain results can then be obtained by applying a numerical inverse Laplace transform. Expressions for the winding’s input impedance with different treatments of the transformer’s neutral point will be derived for any assumed number of the equivalent two-ports. Results pertinent to the frequency characteristics including the resonance frequencies are presented. The paper also describes the winding’s transient response to the application of two standard voltage stimuli. The suggested approach is validated by its application to a case study for which an analytical closed-form solution is available. The analysis of windings exhibiting nonuniformities in more than one equivalent.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2014, 17, 1; 1-11
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compared analysis of the transients and the steady states of squirrel-cage motor and LSPMSM
Autorzy:
Barański, M.
Idziak, P.
Łyskawiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/97457.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
squirrel-cage motor
line start permanent magnet synchronous motor
starting process
heating
functional parameters
Opis:
In the paper the transients under starting process and the steady states of squirrel-cage motor (IM) and line start permanent magnet synchronous motor (LSPMSM) have been compared. The original stator of 3 kW induction motor type Sg 100L-4B, was used in both structures. In order to determine opportunities to increase energy parameters of LSPMSM the heating curves of both motors were compared. In LSPMSM the rotor with aluminum and copper cage was used. The basic operating parameters of the two structures which are characterized by identical stators were tested. Particular attention has been given to the transient under starting process. Efficiency, power factor and current in the stator windings obtained during measurements for both structures have been presented. The paper focuses on achieving a much higher output power for LSPMSM than an induction motor of the same size. The selected results of experimental tests were shown.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 265-274
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients of electrical and mechanical quantities of a brushless DC motor - computations, measurements
Autorzy:
Ciurys, M.
Dudzikowski, I.
Powiązania:
https://bibliotekanauki.pl/articles/141324.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
maszyna elektryczna
silnik bezszczotkowy
magnes trwały
silnik BLDC
obliczenia
pomiary
electrical machines
BLDC motors
permanent magnets
computations
measurements
Opis:
The paper presents a method of computing electrical and mechanical variables of BLDC motors. It takes into account electrical, magnetic and mechanical phenomena in the power supply-converter-BLDC motor-load machine system. The solution to the problem is the so-called circuit-field method. The results determined with the use of time stepping finite element method were used as the parameters of equations of the developed mathematical model. Losses in the motor, losses in transistors and diodes of the converter as well as the actual back EMF waveforms, variable moment of inertia and variable load torque are accounted for. The designed laboratory stand and the test results are presented in the paper. The experimental verification shows the correctness of the developed method, algorithm and program. The developed computational method is universal with respect to different electromechanical systems with cylindrical BLDC motors. It can be applied to electromechanical systems with BLDC motors operating at constant but also variable load torque and moment of inertia.
Źródło:
Archives of Electrical Engineering; 2011, 60, 1; 23-34
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study
Autorzy:
Oramus, P.
Chmielewski, T.
Kuczek, T.
Piasecki, W.
Szewczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/140943.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arc modelling
overvoltages studies
EMTP-ATP program
transients analysis
Opis:
Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 441-458
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the stator inductances of the expanded Park model and an approach on parameter identification using the evolution strategy
Autorzy:
Schmuelling, Ch.
Kreischer, Ch.
Gołebiowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141147.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
evolution strategy
FEM
Park equations
Park theory
synchronous machines
transients
Opis:
Commonly, the Park model is used to calculate transients or steady-state operations of synchronous machines. The expanded Park theory derives the Park equations from the phase-domain model of the synchronous machine by the use of transformations. Thereby, several hypothesis are made, which are under investigation in this article in respect to the main inductances of two different types of synchronous machines. It is shown, that the derivation of the Park equations from the phase-domain model does not lead to constant inductances, as it is usually assumed for these equations. Nevertheless the Park model is the most common analytic model of synchronous machines. Therefore, in the second part of this article a method using the evolution strategy is shown to obtain the parameters of the Park model.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 585-599
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Transient Performance of Partially-Undergrounded Overhead Lines in the Presence of Corona
Autorzy:
Saied, Mohamed M.
Powiązania:
https://bibliotekanauki.pl/articles/262791.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
distributed parameter circuits
non-uniform lines
power transmission lines
line modeling
transients
power networks
mixed
overhead-cable lines
partial undergrounding
distributions
mathematica
Opis:
The paper presents a method for investigating the electromagnetic transients of partially under-grounded high voltage overhead transmission lines in the presence of corona. It is based on a time domain model in which the corona is simulated by distributed voltage-dependent shunt current sources. The line segments and the inserted cable section are represented by a single equivalent transmission element having location-dependent circuit parameters per unit length. The numerical solution of the resulting set of differential equations yields the distributions of the voltage, the longitudinal current and the shunt corona current (per unit length) as functions of location and time. The presented two-, three-dimensional and contour plots proved to be helpful in discussing these distributions and in identifying any eventual current and/or voltage concentrations. The developed computer code in Mathematica can handle any time waveform of the source initiating the transients, any line termination as well as any lengths of the overhead line and cable section.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2019, 21, 1; 1-8
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza procesów zachodzących podczas załączania transformatora pieca łukowego zasilanego z układu z filtrami wyższych harmonicznych
Transients analysis during arc furnace transformer energization in environment of harmonic filters
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/377163.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
prąd rozruchowy
transformator piecowy
filtr wyższych harmonicznych
Opis:
Praktyka eksploatacji układów zasilania pieców łukowych prądu przemiennego pokazała, że wielokrotne komutacje technologiczne transformatorów piecowych mogą stać się przyczyną uszkodzenia transformatora systemowego i innych urządzeń sieci zasilającej. W pracy zbadano wpływ konfiguracji sieci zasilającej na charakter procesów przejściowych jednostki piecowej średniej mocy 50 MVA. Analizę zachodzących procesów przejściowych w układzie zasilania pieca łukowego przeprowadzono stosując model zrealizowany w pakiecie Matlab/Simulink.
The practice of operating AC electrical arc furnace power supply systems has shown that frequent energizing unloaded furnace transformer can cause damage of the system transformer and other system devices. To examination of supply system configuration impact on switching transient nature an example of 50 MVA arc furnace unit was chosen. The transient analysis has been carried out by simulating within Matlab/Simulink software.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 79; 279-287
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie matematyczne procesów rozruchu układów napędowych podnośników budowlanych
Mathematical modelling of transients in drives of building elevating devices
Autorzy:
Kharchenko, Y.
Sobkowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/328348.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
podnośnik
układ napędowy
rozruch
modelowanie matematyczne
diagnostyka
elevator
drive syatem
starting-up
mathematical modelling
technical diagnostics
Opis:
W pracy rozpatruje się wyniki modelowania matematycznego procesów rozruchu układów napędowych podnośników budowlanych. Analizę zjawisk dynamicznych wykonano poprzez wspólne całkowanie równań ruchu elementów układu oraz równań stanu elektromagnetycznego silnika asynchronicznego. Zbadano wpływ masy ładunku i masy przeciwwagi na działające siły dynamiczne w linach.
Results of mathematical modelling of processes of start-up of drives of building elevating devices are analyzed. Calculation of dynamic processes is carried out by joint integration of the equations of movement of elements of systems and the equations of the electromagnetic phenomena in asynchronous engines. Influence of structure of the device and its mechanical characteristics on dynamic efforts in elastic parts is investigated.
Źródło:
Diagnostyka; 2005, 35; 37-42
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control of operability of Peltier modules in cooling systems based on the analysis of transient operating modes
Autorzy:
Kuzichkin, Oleg Rudolfovich
Konstantinov, Igor Sergeevich
Vasilyev, Gleb Sergeevich
Surzhik, Dmitry Igorevich
Powiązania:
https://bibliotekanauki.pl/articles/1845461.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermoelectric system
agriculture
complex
transients
peltier effect
identification algorithms
Opis:
The paper is devoted to the control of operability of Peltier modules based on the analysis of transient modes of their operation. Advantages of using low-power thermoelectric modules for the development of thermoelectric plants with adaptive control systems for the needs of the agricultural complex, which significantly reduce their cost characteristics, are shown. The problem of using the stationary mode of their operation, associated with the low efficiency of the modules, as well as the dynamic mode, associated with the presence of transient processes, is indicated. It is noted that overcoming this problem requires solution of the task of automation of reliability providing the well-known approaches to its solution are shown, for which the key advantages and disadvantages are given. An approach is proposed to complex control of the operability and quality of thermoelectric modules during their expluatation in three components of the physical process of thermoelectric conversion (Peltier thermoelectric effect, electrical and thermal transfer phenomena) by analyzing transients in the system based on identification algorithms. To justify it, the necessary equations and mathematical relations are given. Aprobating of the proposed approach was carried out experimentally by determining the time constants for operable and defective commercially available modules and showed its significant advantages over the standard verification procedure.
Źródło:
Archives of Thermodynamics; 2021, 42, 2; 31-42
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozrusznik samochodowy z bezszczotkowym silnikiem prądu stałego
Car starter with brushless direct current motor
Autorzy:
Ciurys, M.
Dudzikowski, I.
Powiązania:
https://bibliotekanauki.pl/articles/320357.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
rozruszniki samochodowe
silniki bezszczotkowe
magnesy trwałe
obliczenia
stany dynamiczne
car starters
brushless direct current motors
permanent magnets
computations
transients
Opis:
Opracowano model matematyczny, algorytm i program obliczeń przebiegów czasowych wielkości elektrycznych i mechanicznych w układzie: akumulator - rozrusznik samochodowy z bezszczotkowym silnikiem prądu stałego (BLDC) - silnik spalinowy. Opracowany model matematyczny, algorytm i program obliczeń uwzględniają, m.in.: zmienność momentu bezwładności układu korbowego silnika spalinowego, zmienność momentu kompresji i dekompresji gazów w cylindrach oraz zależność momentu tarcia silnika spalinowego od prędkości chwilowej wału korbowego. Obliczono przebiegi czasowe wielkości elektrycznych i mechanicznych w analizowanym układzie.
A mathematical model, algorithm and program for calculations of electrical and mechanical quantities transients in the system: accumulator — starter with brushless direct current motor - combustion engine were developed (Figs 1, 2, 3). The developed mathematical model, computational algorithm and program take account of the combustion engine crankshaft moment of inertia variations as well as the variations of both the compression and decompression torque in the cylinders and the combustion engine friction torque dependence on the instantaneous crankshaft speed. Transients of electrical and mechanical quantities in the analysed system were calculated (Figs 4, 5).
Źródło:
Elektrotechnika i Elektronika; 2006, 25, 2; 129-132
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new closed loop speed control strategy for a vector controlled three-phase induction motor drive
Autorzy:
Tripathi, A.
Dey, A.
Dwivedi, B.
Singh, B.
Chandra, D.
Powiązania:
https://bibliotekanauki.pl/articles/262777.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
space vector modulation
VSI
induction motor model
transients
steady state value
Opis:
This paper presents a completely mathematical equations based model on control of torque and speed of a three-phase indirect vector controlled VSI fed cage induction motor drive that is controlled through the space vector modulated method. This enables a wide range of acceptability of the model for various values of load and for various types and ratings of induction motors. The uniqueness of the model lies in the fact that the deviations in the torque and speed on sudden application of reference step change in speed values are minimum i.e. when any sudden change in the speed reference is desired, the speed and torque waveforms reveal that the time taken in coming back to their final steady state values is very less and the motor overcomes the perturbation with negligible transients. The same is verified through the simulated results.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 1; 67-72
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przebiegi nieustalone prądu i momentu elektromagnetyczneco podczas rozruchu w silnikach indukcyjnych wysokoobrotowych
Transients of current and electromagnetic torque during start-up in high-speed induction motors
Autorzy:
Zielińska, M.J.
Zieliński, W.G.
Zieliński, W.
Powiązania:
https://bibliotekanauki.pl/articles/1373753.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
silnik wysokoobrotowy
rozruch
Opis:
High-speed motors are produced in Poland outside the machine-building industry. Only a few motors, adapted to specific purposes, are manufactured, for example, by plants that produce rolling-element bearings. These motors have found their application in driving high-speed grinders in bearing ring raceway production lines. The properties of motors fed with high-frequency voltage result mainly from the use of a closed slot in the rotor and the high frequency of supply voltage. The use of the closed rotor slot causes strong saturation of the magnetic circuit by the leakage flux around the slot. Taking account of the phenomenon of saturation of the magnetic circuit due to the leakage flux around the closed rotor slots is a complex issue. In the present article, this phenomenon was taken into consideration by introducing into the mathematical model of the motor, derived for a linear magnetic circuit, rotor leakage inductance dependent on rotor current. The relation was determined experimentally.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2009, 82; 249-252
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time and electric energy losses minimization in speed control of induction motors
Autorzy:
Kawecki, L.
Niewierowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/205536.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
optymalizacja
sterowanie optymalne
zasada maksimum
electric energy losses minimization
electromagnetic transients
induction motors
machine control
optimal control
optimal frequency starting
speed control
Opis:
The paper presents a method for solving the problem of the simultaneous time and electric energy losses minimization during the frequency speed control of induction motors with the electromagnetic transients. To solve this vector optimization problem, the optimization index in the form of linear combination of the scalar indexes is assumed and the Pontryagin maximum principle is used. Examples of solution for two cases of optimal frequency starting of two induction motors are presented.
Źródło:
Control and Cybernetics; 1999, 28, 2; 331-353
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical solutions for the control and command system of a Plasma Focus device
Autorzy:
Martin, D. I.
Zoita, V. I.
Cotruta, D. A.
Jianu, A. V.
Ighigeanu, D. I.
Bestea, V. I.
Powiązania:
https://bibliotekanauki.pl/articles/147621.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
control system
electromagnetic transients
galvanic separation
plasma focus
Opis:
The paper presents the technical problems related to the electrical control and command system (ECC system) for the plasma focus installation IPF-4/5A having the following main parameters: 1 MA plasma current and 40 kJ energy stored at 20 kV charging voltage. The ECC system applies 23 interlocked logical commands, acquires and processes 28 logical states, acquires, processes and displays continuously the main slow-varying signals coming from IPF-4/5A subassemblies. All the plasma focus installation operational sequences are governed by strict hard and soft interlocking using in parallel two control and command systems: one based on PC-control methods and another based on classical control techniques.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 89-91
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Rho-associated kinase inhibition on actin cytoskeleton structure and calcium response in glioma C6 cells
Autorzy:
Targos, Berenika
Pomorski, Paweł
Krzemiński, Patryk
Barańska, Jolanta
Rędowicz, Maria
Kłopocka, Wanda
Powiązania:
https://bibliotekanauki.pl/articles/1041182.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
glioma C6
actin cytoskeleton
RhoA
ROCK
calcium transients
Opis:
The role of actin cytoskeleton functional state in glioma C6 cell morphology and calcium signaling was investigated through modification of myosin II activity by blocking Rho-associated kinase with the specific inhibitor Y-27632. Treatment of glioma C6 cells with ROCK inhibitor resulted in actin cytoskeleton reorganization and also in the changed shape and distribution of mitochondria. Changes in the distribution of ER, the main calcium store in glioma C6 cells, were not visible. The inhibition of myosin II activity influences the first phase of calcium signaling evoked by agonist, and both phases of thapsigargin-evoked calcium response. We suggest that the observed increase in Ca2+ release from intracellular stores induced by IP3 formation as well as inhibition of SERCA ATPase is at least in part related to severely affected mitochondria. Enhancement of capacitative calcium entry evoked by thapsigargin is probably associated with the reorganization of the acto-myosin II system. ATP-induced calcium response presents no changes in the second phase. We observed that ATP stimulation of Y-27632 pretreated cells leads to immediate morphological rearrangement of glioma C6 cells. It is a consequence of actin cytoskeleton reorganization: formation of stress fibers and relocation of phosphorylated myosin II to actin filaments. It seems that the agonist-evoked strong calcium signal may be sufficient for myosin II activation and the stress fiber organization. This is the first work showing the dependence between the functional state of the acto-myosin II system and calcium signaling stressing the reversible character of this relationship.
Źródło:
Acta Biochimica Polonica; 2006, 53, 4; 825-831
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Program PSCAD/EMTDC jako wygodne narzędzie do modelowania linii napowietrznych
Modelling of Overhead Lines by the PSCAD/EMTDC
Autorzy:
Smolarczyk, A.
Chmielak, W.
Powiązania:
https://bibliotekanauki.pl/articles/158669.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
linie napowietrzne
stany przejściowe
modelowanie
PSCAD/EMTDC
overhead lines
transients in power systems
power system modelling
PSCAD/EMTDC software
Opis:
W artykule opisano jeden z programów do symulacji zjawisk dynamicznych występujących w systemie elektroenergetycznym. Program o nazwie PSCAD/EMTDC jest powszechnie używany do modelowania fragmentów systemu elektroenergetycznego i zjawisk w nich występujących. Przedstawiono dostępne w programie modele linii napowietrznych, które mogą zostać wykorzystane do modelowania takich sytuacji jak stany łączeniowe (załączenia, wyłączenia) linii, zwarcia w linii. W programie linie napowietrzne można zamodelować ręcznie za pomocą elementów pasywnych typu R, L, C, z wykorzystaniem gotowych czwórników typu PI, za pomocą gotowych modeli typu Bergeron Model, Frequency Dependent (Mode) Model, Frequency Dependent (Phase) Model. Pokazano przykładowy sposób zamodelowania linii WN 110 kV z wykorzystaniem słupów kratowych typu B2 za pomocą modelu typu Frequency Dependent (Phase) Model.
The article describes one of the programs for the simulation of dynamic phenomena occurring in the power system. The program called PSCAD/EMTDC is commonly used to model the parts of the power system and phenomena occurring in them. The models of the overhead lines that can be used for modelling situations such as switching states of the line, short-circuit line have been presented. Overhead lines can be manually modelled using passive R, L, C elements by using prepared PI section elements, using prepared Bergeron Model, Frequency Dependent (Mode) Model, Frequency Dependent (Phase) Model. It was shown how to model a high-voltage line 110 kV with the use of type B2 towers by the Frequency Dependent (Phase) Model.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 272; 31-48
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie przebiegów nieustalonych w nieliniowym i zlinearyzowanym modelu zespołu wytwórczego pracującego w systemie elektroenergetycznym
Comparison of transients for the nonlinear and linearized model of a generating unit working in a power system
Autorzy:
Paszek, S.
Pruski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1372836.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
system elektroenergetyczny
układ jednomaszynowy
zespół wytwórczy
nieliniowość
Opis:
The paper presents the investigation results dealing with reconstruction of output waveforms of the nonlinear generating unit model on a basis of the state matrix eigenvalues of the model linearized at the determined working point. There were considered the waveforms of the terminal voltage, the instantaneous power and the field current of a synchronous generator in the case of step and impulse change of the regulator reference voltage. Linearization of the system model allows obtaining the results in analytical form. The exemplary calculations were carried out in Matlab - Simulink environment for the generating unit model consisting of "Configurable Subsystems" blocks enabling the choice of a generator, an excitation system, a turbine and a power system stabilizer model. The waveforms obtained from simulations on the nonlinear model were compared with those reconstructed from the eigenvalues dependently on the model complexity and nonlinearity level. There was also compared the waveform reconstruction accuracy obtained when using the all eigenvalues and when neglecting the eigenvalues of small participation factor absolute values. From the calculations it follows that the influence of the waveform reconstruction accuracy on nonlinearity of the generator magnetization characteristic is dominant, especially for loads close to the rated one. Neglecting in the waveforms reconstructed the eigenvalues of small participation factor absolute values does not result in significant deterioration of the reconstructed waveform quality, while it allows simplifying the system transmittance.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 88; 181-185
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of a water hammer and cavitation on vibration transients in a reservoir-pipe-valve system
Autorzy:
Miao, Yang
Qiu, Zaihui
Zhang, Xiaolu
Jiang, Yuncheng
Pan, Jun
Liu, Yi
Zhang, Li
Li, Kun
Powiązania:
https://bibliotekanauki.pl/articles/2055065.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
reservoir-pipe-valve system (RPV system)
water hammer
vibration
cavitation
Opis:
An extraordinary phenomenon with violent oscillation, accompanied by an abnormal “click” sound is observed during the valve closing in a fuel feeding pipe system. A fluctuation model with flow cavitation, in which time-varying stiffness, time-varying damping coefficients and flow cavitation are comprehensively considered, is proposed. On this basis, a dynamic vibration equation is established and an expression of flow pressure at the valve port is derived. The critical displacement of the flow cavitation system is defined. When the vibration amplitude reaches the critical displacement, cavitation occurs. Based on this model, simulation of vibration displacement and flow pressure is given. The simulated transient process shows the phenomena of vibration fluctuation with cavitation. The results are compared with the experimental data measured by a pressure sensor. Under our experimental conditions, the critical displacement of vibration is 1.41mm, and the average relative pressure peak error is 0.022. The comparison between the simulation and experimental results shows that they are in an acceptable agreement.
Źródło:
Journal of Theoretical and Applied Mechanics; 2021, 59, 4; 611--622
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients of Carrier Recombination and Diffusion in Highly Excited GaN Studied by Photoluminescence and Four-Wave Mixing Techniques
Autorzy:
Juršėnas, S.
Miasojedovas, S.
Kurilčik, G.
Žukauskas, A.
Aleksiejūnas, R.
Malinauskas, T.
Sūdžius, M.
Jarašiūnas, K.
Powiązania:
https://bibliotekanauki.pl/articles/2041739.pdf
Data publikacji:
2005-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Ey
72.20.Jv
78.55.Cr
Opis:
Time-resolved photoluminescence and four-wave mixing techniques have been combined for studies of carrier relaxation dynamics in a highly photoexcited GaN epilayer. For a moderate excitation density below 1 mJ/cm$\text{}^{2}$, carrier recombination was due to free carrier capture by deep traps. The characteristic time of carrier capture,τ$\text{}_{e}$=550 ps, was measured under deep trap saturation regime. The ambipolar diffusion coefficient for free carriers, D=1.7 cm$\text{}^{2}$/s, was estimated from the analysis of the transients of the light-induced gratings of various periods. A complete saturation of the four-wave mixing efficiency was observed for the excitation energy density exceeding 1.5 mJ/cm$\text{}^{2}$. The latter saturation effect was shown to be related to electron-hole plasma degeneration, which results in a significant enhancement of carrier recombination rate due to onset of stimulated emission.
Źródło:
Acta Physica Polonica A; 2005, 107, 2; 240-244
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A coupled field-circuit model of a 5-phase permanent magnet tubular linear motor
Autorzy:
Tomczuk, B.
Waindok, A.
Powiązania:
https://bibliotekanauki.pl/articles/141318.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
silnik synchroniczny liniowy
magnes trwały
PMLSM
metoda polowo-obwodowa
symulacja
parametry sterowania
permanent magnet linear synchronous motors
field-circuit method
simulation of the transients
control parameters
Opis:
A method for modeling of the dynamics characteristics for a 5-phase permanent magnet tubular linear motor (PMTLM) is presented. Its electromagnetic nonlinear field analysis with finite element method (FEM) has been coupled with the circuit model. The calculation model includes the equations for electrical circuits and mechanical quantities as well. They have been obtained using Lagrange's method. The calculated and measured waves of the mover position have been compared for several values of the excitation current. This comparison yields a good agreement. Presented calculation model is very useful in designing and optimization of the PMTLM and in the calculation of the parameters for the control algorithms intended for such a type of actuators.
Źródło:
Archives of Electrical Engineering; 2011, 60, 1; 5-14
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ technologicznych odchyleń parametrów filtrów harmonicznych na stany przejściowe w sieciach przemysłowych
Impact of filter circuit manufacturing tolerances on industrial supply system transients
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/376396.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
bateria kondensatora
dławik filtrujący
filtr wyższych harmonicznych
strojenie projektowe i dokładne
kompensator statyczny SVC
proces przejściowy
komutacje łączeniowe
Opis:
Praktyka eksploatacji układów kompensacyjno-filtrujących w różnych topologiach i systemach zasilana pokazała, że strojenie filtrów powinno odbywać się dla częstotliwości nieco niższej, niż wielokrotność częstotliwości podstawowej. W pracy, w oparciu o model zrealizowany w pakiecie Matlab/Simulink zbadano wpływu technologicznych odchyleń parametrów elementów filtru na występujące stany przejściowe. Poprzez zmianę strojenia jednostki filtrującej, utożsamianą ze zmianą tolerancji indukcyjności dławika oraz pojemności baterii kondensatorów filtru, porównano wartości udarów prądowych i przepięć generowanych na elementach układu filtrującego podczas komutacji łączeniowych.
The practice of operating multiple, single-tuned FC units in different power supply systems has shown that harmonic filters tuning should be carried out for lower frequencies than multiple of network frequency. To examination of the filter components parameters tolerances impact on switching transients Matlab/Simulink software was chosen. The influence of the filter tuning on switching transients behavior under arc furnace unit and harmonic filters energizing was analyzed. The paper focuses on the comparison of the switching transients due to different tolerances of air-core reactor inductances and capacitor bank capacitances in single and multiple harmonic filters configurations.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 89-100
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza powównawcza stanów pracy silników indukcyjnego i synchronicznego z magnesami trwałymi i klatką rozruchową
Compared analysis of the transients under starting process and the steady states of squirrel-cage motor and LSPMSM
Autorzy:
Barański, M.
Idziak, P.
Łyskawiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/377000.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
silnik synchroniczny magnetoelektryczny
silnik indukcyjny
rozruch
nagrzewanie
Opis:
W artykule porównano pracę w stanie ustalonym i podczas rozruchu dwóch silników: synchronicznego magnetoelektrycznego o rozruchu bezpośrednim (LSPMSM) oraz indukcyjnego klatkowego (IM). W obu konstrukcjach wykorzystano stojan silnika indukcyjnego typu Sg 100L-4B o mocy 3 kW. W silniku synchronicznym zastosowano klatkę rozruchową wykonaną z aluminium i z miedzi. Zbadano proces rozruchu tych maszyn. W celu określenia możliwości polepszenia parametrów użytkowych silnika o magnesach trwałych porównano krzywe nagrzewania silników. Dla obu konstrukcji zestawiono wyznaczone na podstawie pomiarów wartości: sprawności, współczynnika mocy i prądów silnika. Zbadano możliwość uzyskania znacznie większej mocy użytecznej silnika magnetoelektrycznego w stosunku do silnika indukcyjnego mającego te same gabaryty.
In the paper the transients under starting process and the steady states of line start permanent magnet synchronous motor (LSPMSM) and squirrel-cage motor have been. The stator of 3kW induction motor, Sg 100L-4B, was used in both structures. In order to determine opportunities to increase engine performance parameters of LSPMSM the heating curves of both motors were compared. In LSPMSM the rotor with aluminum and copper cage was used. The basic operating parameters of the two structures which are characterized by identical stators was compared. Particular attention has been given to the transient under starting process. Efficiency, power factor and current in the stator windings obtained during measurements for both structures have been presented. Particular attention was paid to the possibility to obtain much greater output power for LSPMSM than for induction motor of the same size. The selected results of experimental tests was shown.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 77; 155-163
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of transient flows in a hydraulic system with a long liquid line
Symulacja przepływów przejściowych w układzie hydraulicznym z hydrauliczną linią długą
Autorzy:
Zarzycki, Z.
Kudźma, S.
Kudźma, Z.
Stosiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/281500.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
układy hydrauliczne
pulsacje pomp
uderzenia hydrauliczne
unsteady pipe flow
transients
pulsation of pump
Opis:
The paper presents the problem of modelling and simulation of transients phenomena in hydraulic systems with long liquid lines. The unsteady resistance model is used to describe the unsteady liquid pipe flow. The wall shear stress at the pipe wall is expressed by means of the convolution of acceleration and a weighting function which depends on the (laminar or turbulent) character of the flow. The results of numerical simulation are presented for the waterhammer effect, which is caused by a sudden shift of the hydraulic directional control valve. The following cases of the system supply are considered: the first, with a constant delivery rate of the pump and the second, which additionally considers pulsation of the delivery of the pump. Computer simulations are compared with results of experiments. They are found to be very consistent in the case with the variable rate of the pump delivery taken into accent.
Artykuł przedstawia zagadnienie modelowania i symulacji zjawisk przejściowych w układach hydraulicznych z hydrauliczną linią długą. Wykorzystano model tarcia niestacjonarnego do opisu niestacjonarnego przepływu w przewodzie. Naprężenia ścinające na ściankach przewodów są określone za pomocą przyspieszenia i finkcji wagi, która zależy od charakteru przepływu (uwarstwiony, turbulentny). Rezultaty symulacji numerycznych są prezentowane dla uderzenia hydraulicznego, które spowodowane jest poprzez nagłe przesterowanie rozdzielacza. Rozpatrywane są dwa przypadki: pierwszy - gdy układ zasilający podaje stałą wartość natężenia przepływu, drugi uwzględniający pulsację wydajności pompy wyporowej. Symulacje komputerowe są porównane z wynikami badań eksperymentalnych. Wykazano dużą zgodność symulacji komputerowych uwzględniających pulsację wydajności pompy z wynikami eksperymentu.
Źródło:
Journal of Theoretical and Applied Mechanics; 2007, 45, 4; 853-871
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczenia elektromagnetyczne przetwornika o ruchu złożonym opartego na wspólnym obwodzie magnetycznym
Analysis of the Dynamic and Stationary States of a Car Starter with Permanent Magnet Motor
Autorzy:
Ciurys, M.
Dudzikowski, I.
Powiązania:
https://bibliotekanauki.pl/articles/1368124.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
rozruszniki samochodowe
magnesy trwałe
przebiegi czasowe
electrical machines
car starters
permanent magnets
transients
Opis:
Using field – circuit method transients of the electric and magnetic quantities of the developed car starter motor with ferrite magnets were determined at dynamic and stationary operating conditions. These results were used, in the developed mathematical model, algorithm and software, to determine mechanical and electrical transient in the system: battery – electrical motor – mechanical transmissions – combustion engine. Transients of the analysed electromechanical system were determined taking into account the variations of inertia, the variations of the load torque generated by combustion engine and the influence of the temperature on the battery parameters, magnets parameters and load torque generated by the combustion engine. Electromechanical characteristics of the car starter were determined.
Metodą polowo-obwodową wyznaczono przebiegi czasowe wielkości elektrycznych i magnetycznych w opracowanym silniku rozrusznika samochodowego z magnesami ferrytowymi w dynamicznych i ustalonych stanach pracy. Wyniki te wykorzystano w opracowanym modelu matematycznym, algorytmie i programie do wyznaczania przebiegów wielkości mechanicznych i elektrycznych w układzie: akumulator – silnik elektryczny – przekładnie mechaniczne – silnik spalinowy. Wyznaczone przebiegi czasowe w analizowanym układzie elektromechanicznym uwzględniają zmienność momentu bezwładności i zmienność momentu obciążenia generowanego przez silnik spalinowy oraz wpływ temperatury na parametry akumulatora, parametry magnesów i na moment obciążenia generowany przez silnik spalinowy. Wyznaczono charakterystyki elektromechaniczne rozrusznika.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 3, 100/1; 141-146
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu uszkodzenia tranzystora IGBT falownika napięcia na przebiegi zmiennych stanu w napędzie indukcyjnym
Analysis of the influence of IGBT transistor fault in voltage inverter to state variable transients of the induction motor drive
Autorzy:
Sobański, P.
Orłowska-Kowalska, T.
Powiązania:
https://bibliotekanauki.pl/articles/1811989.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
silnik indukcyjny
falownik napięcia
uszkodzenie łącznika
diagnostyka uszkodzeń
Opis:
The aim of the paper is an analysis of the state variable transients in the direct oriented control of induction motor drive under open-switch fault of the voltage inverter. Study results that were presented, were obtained by simulation tests by MATLAB/Simulink environment. The paper is an introduction to the problem of power converter fault-tolerant control methods for electric drives.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 145-152
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ charakterystyk eksploatacyjnych sieci przemysłowych na dobór parametrów filtrów harmonicznych
Impact of industrial network operating characteristics on the harmonic filter parameters sizing
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/268765.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
filtr wyższych harmonicznych
stany ustalone
stany przejściowe
bateria kondensatora
dławik filtrujący
harmonic filter
steady state
transients
capacitor bank
air-core filter reactor
Opis:
Układy kompensacji mocy biernej oraz filtracji, oparte na kondensatorach znajdują powszechne zastosowanie w praktycznych rozwiązaniach systemów przemysłowych. Ich parametry znamionowe wyznaczane są wyłącznie w oparciu o harmoniczne prądów oraz napięć w stanach ustalonych, niemniej jednak tyczy się to głównie jednostek filtrujących o prostej topologii. Stąd, mając na uwadze bardziej złożone układy w większości przypadków istniejących lub nowoprojektowanych obiektów wymaga się, aby analizowane układy były dostosowane do pracy zarówno w warunkach ustalonych jak i przejściowych. Korzystając ze standardów oraz norm, w artykule omówiono procedurę doboru parametrów baterii kondensatorów oraz dławików układów filtrujących z pozycji ich bezawaryjnej pracy w elektrycznych sieciach przemysłowych. Zaproponowana metoda ma wspomóż działania projektowe filtrów harmonicznych.
The application of harmonic filter circuit based on power capacitor banks are widely used in practical solutions in industrial systems. The component ratings of these units are often specified based solely on a combination of steady state fundamental and harmonic voltages and currents. Although, this may be adequate in single-tuned or single branch units and method may not properly rate the components for more complex applications such as multiple, single-tuned harmonic filter circuits in compensated installations. Thus, in the most cases of commonly used or newly designed circuits are required to be adapted to operate as well in steady state and transients conditions. Using the exsisting Standards, the article propose a method for determining equipment ratings parameters of the capacitor banks and air-core filter reactors according to malfunctions. The study illustrated in this paper will be used to support and improve harmonic filter realiability and design. It is hoped that ideas will be a resource for a future filter application guide being contemplated by the capacitor subcommittee.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 47-51
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu sposobu namagnesowania magnesów na przebiegi czasowe wielkości elektrycznych i mechanicznych w silniku bezszczotkowym
Analysis of the permanent magnets magnetization on the transients of the electrical and mechanical quantities of a brushless dc motor
Autorzy:
Ciurys, M.
Dudzikowski, I.
Kmieć, P.
Powiązania:
https://bibliotekanauki.pl/articles/1813548.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
silnik bezszczotkowy
magnesy trwałe
przebiegi czasowe
obliczenia
pomiary
Opis:
Circuit-field models of the brushless DC motor with parallel and radial magnets magnetization were developed. Transients of the electrical and mechanical quantities of the motor were determined at parallel and radial magnets magnetization. Experimental verification was carried out. The computed and the measured transients were compared.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 258-266
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sozdanie ehlektronnykh diagnosticheskikh sredstv gidravlicheskikh privodov kombajjnov na osnove dinamicheskikh perekhodnykh processov ikh funkcionirovanija
Creation of electronic diagnostic means of hydraulic drives of combines on the basis of dynamic transients of their functioning
Autorzy:
Jaremenko, V.
Kucenko, A.
Chernysh, O.
Bondar, M.
Powiązania:
https://bibliotekanauki.pl/articles/78245.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
hydraulic drive
diagnosis
combine
dynamic characteristics
technological operation
control system
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 3
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel power quality data analysis and reporting framework for wide-area system of registration and processing of power quality data
Autorzy:
Rezmer, J.
Leonowicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/136208.pdf
Data publikacji:
2015
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
power quality
faults
power distribution
reliability
power system restoration
power system transients
relational databases
distributed generation
voltage dips
GIS
data visualization
data analysis
localization of disturbances
Opis:
This paper presents a novel method for data analysis and visualization, including real-time visual monitoring and proposal for combined area PQ indices on the example of the developed and operational comprehensive system of registration, archiving and data processing for the wide-area monitoring of power quality in a separated part of real power grid with distributed renewable generation. Real case studies related to power quality disturbances are presented.
Źródło:
Transactions on Environment and Electrical Engineering; 2015, 1, 1; 1-3
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zaburzeń piorunowych indukowanych w modelu wiązki kablowej statku powietrznego
Analysis of lightning induced transients in an aircraft cable bundle model
Autorzy:
Filik, K.
Masłowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/194214.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
przepięcia atmosferyczne
wieloprzewodowa linia transmisyjna
sprzężenia elektromagnetyczne
ekranowanie przewodów
badania eksperymentalne
badania komputerowe
lightning overvoltages
multi-conductor transmission line
electromagnetic coupling
electromagnetic shielding
experimental studies
computer studies
Opis:
W artykule dokonano analizy zaburzeń pochodzenia piorunowego, indukowanych w odcinku modelowej wiązki kablowej, ułożonej nad płaszczyzną metalową, w oparciu o przedstawione wyniki badań eksperymentalnych oraz komputerowych. Do przygotowania układu fizycznego użyto typowych lotniczych przewodów i oplotu ekranującego. Badania przeprowadzono dla wybranych wartości obciążenia linii oraz przy kilku sposobach uziemienia ekranu otaczającego wybrane przewody. W nieekranowanej linii tej samej wiązki wymuszano przepływ prądu udarowego. Zarejestrowano przebiegi czasowe napięć i prądów w określonych punktach systemu, będące efektem obecności zaburzenia piorunowego oraz sprzężeń pojemnościowych i indukcyjnych pomiędzy przewodami. Wyniki badań eksperymentalnych były podstawą do weryfikacji rezultatów symulacji komputerowej wykonanej w pakiecie oprogramowania CST Studio Suite 2017. Na bazie przygotowanej struktury trójwymiarowej badanego układu program umożliwił uzyskanie obwodowego modelu linii transmisyjnej, użytego w późniejszych obliczeniach w dziedzinie czasowej. Badania wykazały zależność konfiguracji obciążenia linii i sposobu jej ekranowania na kształt i wartość szczytową obserwowanych przepięć w układzie. Rezultaty obliczeń komputerowych charakteryzowały się dobrą zgodnością z wynikami eksperymentalnymi. Różnice wynikały między innymi ze stopnia dokładności odzwierciedlenia struktury 3D modelu fizycznego, sposobu zdefiniowania prądu wymuszającego oraz parametrów samej symulacji komputerowej.
The paper presents an analysis of lightning overvoltages induced in the section of cable harness, located above the conducive metal plane, based on the presented results of experimental and computer studies. For the preparation of the physical model, typical wires and braided shield for aviation industry were used. The tests were carried out for various harness configuration. First of all, both the values of the resistive loads on both ends of the wires and the method of grounding the screen surrounding the selected wires were changed. In the unshielded wire of the same bundle, the lightning current was forced using a single impulse generator MIG0618SS with high accuracy and repeatability of generated disturbances. The overvoltages were transferred to the other wires of the line by capacitive and inductive coupling. Voltage and current waveforms at specific points of the system were recorded using a digital oscilloscope. The results of experimental research were the basis for verification of the computer simulation computation made in the CST Studio Suite 2017 software package. On the basis of the prepared 3D structure of the studied system, the program made it possible to obtain an equivalent transmission line model, used for later calculations in the time domain. Studies showed a clear and also the expected relationship of load configuration and the shield grounding method of the cable bundle on the shape and peak value of transients observed in the system. The differences resulted among other, from the degree of 3D model accuracy and the method defining the forcing current and parameters of the simulation. It is planned to use the presented software in further work on the analysis of lightning induced signals in electrical and electronic systems.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Elektrotechnika; 2018, z. 37 [297], nr 1, 1; 5-24
0209-2662
2300-6358
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Elektrotechnika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stany nieustalone towarzyszące pomiarowi impedancji pętli zwarcia w obwodach wyjściowych zasilaczy bezprzerwowych UPS
Transient states associating loop impedance measurement in the output line of UPS power supplies
Autorzy:
Olesz, M.
Katarzyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/266602.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
stany nieustalone
zasilacze bezprzerwowe
pomiary jakości energii elektrycznej
impedancja pętli zwarcia
transients
uninterruptible power supplies
power quality measurements
fault loop impedance
Opis:
W pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem wielokanałowym potwierdziły poprawność danych uzyskiwanych w celu określenia reakcji zasilacza na zaburzenia występujące na wejściu i wyjściu urządzenia. W pracy analizowano wyniki pomiarów impedancji pętli zwarciowej zmierzone przyrządem wymuszającym poziomy prądu zwarciowego na linii zasilającej odbiorniki energii elektrycznej we wszystkich stanach pracy zasilacza, a następnie porównywano je z wynikami obliczeń przeprowadzonych na uzyskanych przebiegach prądu i napięcia.
The paper presents the methodology and the results of transient measurement in on-line Uninterruptable Power Supply (UPS). There were two power quality measurement instruments (synchronised with time) used for registering the events in UPS input and output. The recorders compress the obtained measurement data, which may introduce additional measurement errors of measured values, i.e. voltage and current. Additional registrations with a multi-channel oscilloscope confirmed the correctness of the obtained data in order to determine the reaction of the UPS to the disturbances occurring in UPS input and output. The work analysed the results of loop impedance, measured by a meter that forces short-circuit current in the line supplying electric load, in all states of the UPS, and then they were compared with the results of calculations carried out on the obtained current and voltage waveforms. The measurement of fault loop impedance in UPS output line should be performed in active static switch (bypass mode), because UPS will operate in this mode after switching from inverter operation due to high current forcing during a short circuit in the UPS output. Measurement of fault loop impedance in UPS output circuits, when it is in AC-DC-AC double conversion mode, may result with loop impedance overstating by meters, which in turn limits recognition of the tested installation as safe from the protection against electric shock by automatic power off point of view. The values of calculated loop impedance at forced high current, i.e. 160 A in the UPS output, when it is respectively in the manual bypass and static switch mode, are 4% and 2.5% lower than the ones presented by meter after measure by forcing high current. Differences in impedance of the static switch and manual bypass UPS mode can be the basis for the estimation of the thyristor impedance. Estimation of direct measurement results with 14.6 m, and according to the calculation of recorded transients it is about 16.1 m.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 61; 57-60
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new method for on-line monitoring of bushings, transients and PD of power transformers
Nowe metody monitoringu on-line przepustów, przepięć i wyładowań niezupełnych transformatorów energetycznych
Autorzy:
Koch, M.
Kołtunowicz, W.
Krüger, M.
Powiązania:
https://bibliotekanauki.pl/articles/156993.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
power transformers
bushings
on-line monitoring
dissipation factor
capacitance
PD
UHF
transformator energetyczny
przepust
monitoring on-line
współczynnik strat
pojemność
WNZ
Opis:
This paper describes a new on-line method for capacitance and dissipation factor measurements of high voltage bushings, for recording grid transients and for partial discharge monitoring at power transformers. The needed accuracy for reliable detection of failures is in the range of 5 pF for capacitance and 0.1 % for dissipation factor. To overcome these shortcomings, this paper introduces an absolute method for measuring capacitance and dissipation factor of HV bushings. As for off-line measurements, the discrimination between noise and true internal discharges is the key for successful diagnosis. Strategies for sensitive partial discharge measurements under disturbed on-line conditions are described, also involving measurements in the UHF range.
Artykuł opisuje nowe metody pomiaru on-line pojemności i współczynnika strat przepustów wysokonapięciowych na potrzeby, monitorowania przepięć w sieci i wyładowań niezupełnych w transformatorach energetycznych. Według statystyk awaryjności przepusty WN są jedną z głównych przyczyn awarii transformatorów, co motywuje operatorów do ciągłego monitoringu on-line stanu układów izolacyjnych. Na potrzeby wiarygodnej diagnostyki wymagana jest dokładność pomiaru pojemności rzędu 5 pF i współczynnika strat rzędu 0,1%. Aby uzyskać taką rozdzielczość, wskutek braku symetrii w sieci, nie wystarczy względne porównanie prądów mierzonych w zaciskach pomiarowych w przepustach trzech faz. Dodatkowo, ten sposób pomiaru nie pozwala identyfikować procesu starzenia przebiegającego w trzech fazach ze zbliżonym tempem. W artykule przedstawiono metodę pomiaru rzeczywistych wartości pojemności i współczynnika strat przepustów WN. Pozwala ona uzyskać dokładność podobną do pomiarów off-line nawet w warunkach eksploatacyjnych. Wyładowania niezupełne są wczesnym wskaźnikiem zbliżającego się przebicia w izolacji WN. Ich pomiar na zacisku przepustu WN umożliwia wykrycie defektów w izolacji przepustu oraz transformatora. Podobnie jak w pomiarach off-line, rozróżnienie zakłóceń od rzeczywistych wyładowań wewnętrz izolacji jest kluczem do poprawnej diagnostyki. Opisano strategie czułego pomiaru wyładowań niezupełnych w warunkach on-line, z uwzględnieniem zakresu UHF.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 120-124
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new method for analytic determination of extremum of the transients in linear systems
Autorzy:
Górecki, H.
Powiązania:
https://bibliotekanauki.pl/articles/970346.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
równanie przestępne
układ stacjonarny liniowy
optymalizacja parametryczna
formułka obliczeniowa
wyróżnik funkcji wykładniczej
wyznacznik Vandermondesa
wzór Vietesa
transcendental equations
extremal dynamic error
linear stationary system
parametric optimization
analytic formulae
discriminants of exponential functions
Vandermonde's determinant
Viete's formulae
process control
Opis:
The relation between extremal values of the error and the coefficients of its differential equations is one of the central problems of control systems in chemical industry, because extremal values of the error sometimes cause serious damages to the environment or to the system itself. Analytical formulae for the determination of these values are known only for the second-order systems. In this paper a method which permits to determine extremal values of the error in higher-order systems is proposed.
Źródło:
Control and Cybernetics; 2004, 33, 2; 275-295
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interdyscyplinarne modelowanie procesów nieustalonych w lokalnym układzie elektroenergetycznym zawierającym linie zasilania o parametrach rozłożonych
Mathematical modeling of transients in power system consisting of two subsystems connected among themselves transmission line with distributed parameters
Autorzy:
Czaban, A.
Szafraniec, A.
Levoniyk, V.
Powiązania:
https://bibliotekanauki.pl/articles/253457.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
proces nieustalony
układ energetyczny
minisystem elektroenergetyczny
zasada Hamiltona-Ostrogradskiego
transient process
energy system
MINISYSTEM electricity
Hamilton's principle-Ostrogradskiy
Opis:
W pracy, wychodząc z podejść wariacyjnych, proponuje się model matematyczny lokalnego układu energetycznego, który składa się z dwu minisystemów elektroenergetycznych połączonych między sobą przez długą linię zasila-nia o parametrach rozłożonych. Podukłady energetyczne składają się z linii zasilania o parametrach skupionych, transformatorów mocy oraz obciążenia o charakterze rezystancyjno-indukcyjno-pojemnościowym. Wyjściowe równania przedstawione są w normalnej postaci Cauchy'ego. Wyniki symulacji komputerowej podano w postaci rysunków, które są zinterpretowane i opisane w pracy.
In this paper based on variation approaches the mathematical model of the local power system that consists of two mini power systems, which are interconnected via a long transmission line with distributed parameters. The energy subsystem consists of power lines with concentrated parameters, power transformers and load equivalent to connection active-inductive-capacitive elements. Initial state equation represented in normal Cauchy form. The results of computer simulations are presented in the form of figures that is analyzed.
Źródło:
TTS Technika Transportu Szynowego; 2016, 12; 406-411
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-spark modeling of very fast transient overvoltages for the purposes of developing HV and UHV gas-insulated switchgear and of conducting insulation co-ordination studies
Autorzy:
Szewczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/200835.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
very fast transient overvoltages
VFTO
gas insulated switchgear
GIS
disconnector switch
DS
modeling
simulations
transients
switching
mitigation
breakdown voltage
BDV
odłącznik
modelowanie
symulacje
transjenty
przełączanie
łagodzenie
rozdzielnice izolowane gazem
Opis:
Very fast transient overvoltages (VFTO) originate from steep voltage breakdowns in SF6 gas that are inherent to operation of any switching device of the gas-insulated switchgear (GIS) type. For power stations with voltage ratings exceeding 500 kV, the ratio between equipment rated- and withstand-voltage levels becomes relatively low, which causes the VFTO peak values to reach the component’s insulation withstand-voltage levels, thus becoming a design factor for high- and ultra-high voltage GIS. While well-established approach to VFTO analyses involves only single VFTO events (the so-called single-spark approach), there is often the need to analyze the entire VFTO generation process, for which the multi-spark approach to VFTO modeling is to be employed. The multi-spark approach allows one to evaluate the VFTO impact on the GIS disconnector design along with the impact of the VFTO on selection and dimensioning of the VFTO damping solutions. As the multi-spark approach to VFTO modeling is now being increasingly used in UHV GIS developments as well as for the insulation co-ordination studies of power stations, the present paper is motivated by the need to report on the VFTO multi-spark modeling approach and to lay a common ground for development works that are supported extensively with VFTO simulations. The paper presents physical assumptions and modeling concepts that are in use in such modeling works. Development of the multi-spark GIS disconnector model for VFTO simulations is presented, followed by an overview of examples of the model application for the GIS development works and for insulation co-ordination studies.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 6; 871-882
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nasycenia obwodu magnetycznego i wypierania prądu na przebiegi momentu elektromagnetycznego i prądu podczas rozruchu wysokoobrotowych silników klatkowych
Influence of the saturation of the magnetic circuit and skin effect on the transients of electromagnetic torque and current during the start up of high-speed motors
Autorzy:
Zielińska, M.J.
Zieliński, W.G.
Powiązania:
https://bibliotekanauki.pl/articles/1372567.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik elektryczny
silnik klatkowy
silnik wysokoobrotowy
rozruch silnika
obwód magnetyczny
moment elektromagnetyczny
Opis:
High speed squirrel-cage motors are a relatively unknown group of machines, mainly due to their particular application. High rotational speed is achieved by supplying the motors with 400-1500Hz frequency voltage. Their operation in special conditions results in the fact that their structure and some properties differ from those of squirrel-cage induction machines supplied with 50Hz frequency voltage. The use of closed rotor slots causes strong saturation of the magnetic circuit for the slot leakage flux. Changes in the current in the slot causes a varying state of saturation and thus rotor leakage inductance is not a constant parameter. When determining the rotor winding leakage inductance for classic induction motors supplied with 50Hz frequency voltage, the influence of the saturation of the magnetic circuit for the leakage flux is usually omitted. This is a standard approach and an equivalent scheme, mentioned in literature, is used in such a case. Identification of the inductance in motors supplied with high frequency voltage, in which the phenomenon of core saturation occurs, is a relatively complex issue due to the complicated distribution of magnetic flux, and especially the leakage flux. The value of leakage inductance was determined experimentally. The paper presents differential equations describing a mathematical model and transients of the current and electromagnetic torque, obtained by simulating the start-up of a squirrel-cage high-speed motor.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2011, 3, 91; 183-186
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-70 z 70

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies