Wyszukujesz frazę "indoor air quality" wg kryterium: Wszystkie pola


Tytuł:
Perceived indoor air quality, air-related symptoms and ventilation in Finnish hospitals
Autorzy:
Hellgren, Ulla-Maija
Hyvärinen, Markku
Holopainen, Rauno
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2185474.pdf
Data publikacji:
2011-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
evaluation of ventilation
Indoor Air Questionnaire
perceived indoor air quality
Health care workers
Opis:
Objectives: Good ventilation is more important in hospitals than in many other buildings. The objective of this study was to evaluate the effect of the condition, performance and modernity of ventilation systems on the perceived indoor air quality (IAQ) and the indoor air-related symptoms of hospital personnel. Materials and Methods: An inspection and evaluation graded on a 1 to 3 scale of the condition, performance, and modernity of the ventilation systems was carried out in ten central hospitals in Finland. The perceived IAQ and the related symptoms were collected by means of an indoor air questionnaire survey among the workers in these hospitals. Results: The condition, performance and modernity of the ventilation systems were good in 40% of the hospitals included in the research and poor in another 40% of them. In hospitals where the majority of the ventilation systems were assessed to be good, the prevalence of the indoor air-related complaints and symptoms was lower than in hospitals where the majority of the ventilation systems were assessed as needing extensive repairs. Conclusions: The condition and performance of the ventilation systems in hospitals had a significant impact on the perceived IAQ and the symptoms observed among the employees in Finnish hospitals. Therefore, it is important that hospital ventilation systems are maintained properly and regularly. Furthermore, they should be renovated, at the latest when their technical lifespan expires.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 1; 48-56
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza w wielorodzinnych budynkach mieszkalnych
Indoor air quality in multifamily buildings
Autorzy:
Telejko, M.
Zender–Świercz, E.
Piotrowski, J.Z.
Powiązania:
https://bibliotekanauki.pl/articles/390643.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
jakość powietrza wewnętrznego
mikroklimat
wymiana powietrza
fizyka budowli
indoor air quality
microclimate
air exchange
building physics
Opis:
Obowiązujące aktualnie przepisy prawne regulujące zagadnienia wentylacji naturalnej [1], [2], [3] w wielu obszarach są niejednoznaczne, a niekiedy wręcz sprzeczne. Sytuacja taka prowadzi do stosowania rozwiązań powodujących poważne zaburzenia w działaniu wentylacji grawitacyjnej. W dużej części budynków zaburzenia te są wynikiem dostarczania do pomieszczeń zbyt małej ilości powietrza zewnętrznego. Jak wykazały badania, ze względu na kształtowanie warunków mikroklimatu wnętrz, podstawowe znaczenie ma nie tylko wielkość dostarczanego strumienia powietrza zewnętrznego, ale również rozmieszczenie elementów doprowadzających to powietrze.
The applicable legislation connected with the natural ventilation are ambiguous and sometimes contradictory. This leads to serious problems with natural ventilation. In most cases malfunction of the natural ventilation is due to the insufficient stream of air from the outside. The research showed that the microclimate is influenced not only by the incoming air stream, but also by the layout of the air supply.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 67-74
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of indoor air quality in a store with additional gas heater
Autorzy:
Wysocka, Monika
Załuska, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1177489.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
air pollution
carbon dioxide
gas heater
heating
indoor air quality
thermal comfort
ventilation
Opis:
The quality of the internal environment is an extremely important issue, because users of rooms spend a significant part of the day inside buildings. The quality of the environment is largely dependent on the quality of the indoor air. The parameters of the air we breathe affect our health and the comfort of use of the rooms. Poor indoor air quality can cause a decrease in human comfort and various illnesses and ailments. Therefore, care should be taken to ensure adequate ventilation in the rooms, especially those that have an additional source of pollutant emissions. The purpose of this work is to examine the effect of heating a commercial premises room with a gas heater on air quality. The following parameters were measured as part of the tests: carbon dioxide concentration, air temperature and relative air humidity. The most important parameter significantly affecting the deterioration of the quality of the interior microclimate is carbon dioxide, the level of which reached high values, well above the hygienic minimum (1000 ppm). In order to compare the values of the tested parameters, the measurements were carried out in two options - for a period of five days with the stove running and another two days without additional heating.
Źródło:
World Scientific News; 2018, 102; 209-216
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor air quality in computer labs
Jakość powietrza wewnętrznego w pracowniach komputerowych
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/402282.pdf
Data publikacji:
2015
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
building physics
ventilation
air exchange
indoor air quality
CO2 concentration
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
stężenie CO2
Opis:
The article presents the results of indoor air quality measurements in three university computer labs. In the spaces concerned natural ventilation system has been applied. The obtained results indicate a very low air quality in this type of room.
Źródło:
Structure and Environment; 2015, 7, 4; 194-198
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological indoor air quality in Polish schools
Mikrobiologiczna jakość powietrza w polskich szkołach
Autorzy:
Dumała, S. M.
Dudzińska, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/1818752.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
jakość powietrza
polskie szkoły
Opis:
Większość ludzi spędza ponad 90% swojego życia wewnątrz pomieszczeń m.in.: w domach, biurach i szkołach, gdzie narażeni są na działanie różnych czynników środowiska wewnętrznego (np. bioaerozoli) wpływających na ich zdrowie i kondycję fizyczną. Dlatego w ostatnich latach stale rośnie zainteresowanie badaniami wewnętrznych zanieczyszczeń biologicznych. Celem tych badań jest nie tylko szacunkowa ocena ilości mikroorganizmów w powietrzu, ale również ich identyfikacja i określenie czynników wpływających na skład bioaerozolu wewnątrz pomieszczeń. Biologiczne zanieczyszczenie powietrza w pomieszczeniach jest najczęściej spowodowane przez bakterie i grzyby. Nie tylko samo ich występowanie w formie żywych komórek patogennych może być szkodliwe dla zdrowia, ale również wydzielane przez nie substancje stanowią spore zagrożenie. W artykule zbadano szkoły z terenu Lublina pod kątem zanieczyszczeń mikrobiologicznych. Badania przeprowadzono podczas okresu grzewczego (marzec) i bez ogrzewania (maj). Próbki powietrza pobierano przed lekcją oraz podczas jej trwania. Zidentyfikowano następujące bakterie i grzyby: Bacillus lentus, Bacillus licheniformis, Bacillus pumilus, Bacillus cereus,Pseudomonas stutzeri, Micrococcus ssp., Staphylococcus xylosus, Staphylococcus saprophyticus, Staphylococcus haemolyticus, Acremonium, Aerobasidium, Aspergillus, Aspergillusniger, Alternaria, Cladosporium, Epicocum, Mucor, Penicilinium. Wśród tych drobnoustrojów wykryto obecność mikroorganizmów chorobotwórczych i o silnym działaniu uczulającym.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 231-244
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości powietrza wewnętrznego w wybranych przedszkolach
Indoor air quality in a preschool
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/391209.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
preschool building
Opis:
W artykule przedstawiono wyniki badań jakości powietrza wewnętrznego przeprowadzonych w 4 przedszkolach samorządowych. W rozpatrywanych obiektach zastosowany został system wentylacji grawitacyjnej. Uzyskane wyniki badań wskazują jednoznacznie na bardzo niską jakość powietrza w tego typy budynkach.
The article presents the results of indoor air quality (IAQ) assessment in four local preschools. The natural ventilation system was used in the buildings. Outdoor air was supplied to the premises through a leak in the external walls and air intakes were of maximum efficiency of 30 m3/h. Parameters describing IAQ were measured, such as: temperature, relative humidity and carbon dioxide concentration. Two series of studies were performed in each preschool. On the basis of the survey, it can be clearly stated that the indoor air quality in preschools is considered to be very low very low. All the analyzed parameters describing the quality do not meet the current legal requirements. Reported values of CO2 concentration exceeded three times the value set of the recommended maximum.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 41-48
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba poprawy jakości powietrza wewnętrznego w przedszkolu
Indoor air quality in a preschool
Autorzy:
Koruba, D.
Zender-Świercz, E.
Piotrowski, J.Z.
Orman, Ł.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/390993.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
Opis:
W artykule przedstawiono wyniki badań nad jakością powietrza wewnętrznego (IAQ) w jednym z wybranych przedszkoli. W obiekcie zastosowany został system wentylacji grawitacyjnej. Wstępne badania potwierdziły niską jakość powietrza wewnętrznego w podmiotowym budynku. W trakcie badań zaproponowano dwa usprawnienia mające na celu poprawę jakości powietrza: zwiększenie strumienia powietrza nawiewanego oraz, w drugiej kolejności, montaż urządzeń do uzdatniania powietrza wewnętrznego. Uzyskane wyniki badań wskazują, że wprowadzone usprawnienia wpływają na poprawę jakości powietrza wewnętrznego.
The article demonstrates the results of research on the indoor air quality (IAQ) in one of chosen preschools. In such facilities, the standard solution is a system of natural ventilation. Only a small percentage of such buildings is equipped with a mechanical ventilation system with adjustable parameters of the microclimate. The article presents the results of indoor air quality in the local preschool located in Kielce. In the present facility natural ventilation system was used. Preliminary studies confirmed the poor quality of indoor air in a subjected building. During the study, two improvements aimed at improving air quality were proposed. The first improvement was to increase the supply air stream. The second one concerned the installation of equipment for the treatment of indoor air. The results indicate that under certain guidelines it is possible to improve indoor air quality. As an indicator of indoor air quality, concentration of carbon dioxide was adopted. In addition, microbiological tests were performed indoors.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 7-13
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Gas Chromatography for Indoor-Air Quality Control in Conservation and Renovation Studios
Autorzy:
Ligor, T.
Gorczyca, P.
Buszewski, B.
Powiązania:
https://bibliotekanauki.pl/articles/90290.pdf
Data publikacji:
2005
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
volatile organic compounds (VOCs)
air analysis
gas chromatography
occupational exposure
sample preparation
chromatografia gazowa
zagrożenia chemiczne
jakość powietrza
analiza powietrza
kontrola powietrza
Opis:
Investigations were carried out in the Department of Conservation of Painting and Polychrome Sculpture and in the Screen Printing Studio of the Faculty of Art at Nicolaus Copernicus University. Concentration of the vapours of organic solvents was measured in 2 workshops: the Art Conservation Studio and the Screen Printing Studio. This study attempts to evaluate the work environment in both studios by analysing the concentration of vapour solvents over 5 to 7 years of measurements. Volatile solvents—aliphatic and aromatic hydrocarbons, alcohols, esters and ketones—were detected in investigated workplaces. These compounds have a wide range of applications in cleaning and removing old varnishes, lacquers and paints; inhalation is the main route of exposure. Vapour was collected using an active sampling method.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2005, 11, 3; 251-261
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in Offices and Classrooms in Public Utility Building - a Case Study
Autorzy:
Łuszczyńska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/27314787.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
indoor air quality
bioaerosol
microorganisms
fungi
jakość powietrza w pomieszczeniach
bioaerozol
mikroorganizmy
grzyby
Opis:
A microbiological analysis of indoor air quality in offices, lecture rooms, and hallways in a public utility building has been carried out in the Lubuskie Voivodship (Poland). In one of the storage rooms, the presence of fungi on the building partition was found in the place of water infiltration as a result of a technological failure in the building. A total of 17 nonresidential interiors were examined. The total number of psychrophilic and mesophilic bacteria and the total number of fungi were sampled by the collision method with the air sampler. A qualitative analysis has been performed of fungi present in the indoor air and from building partition of the studied interiors. A total of 11 species of fungi have been specified. Relative humidity and air temperature were measured with a hygrometer. The studies showed that the number of psychrophilic bacteria in indoor air was in the range 0-730 CFU/m3 , while the number of mesophilic bacteria was slightly higher (0-896 CFU/m3 ). A high level of contamination and a large number of fungi (734 CFU/m3 ) were found in the indoor air of storage room, where the problem of biodeterioration of building partitions occurred. In the remaining rooms, the level of microorganisms was low or moderate. Microbiological tests of the outdoor air (background) did not reveal an excessive number of microorganisms in the air.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 3; 228--239
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigations of effect of indoor air quality on thermal comfort in residential buildings
Autorzy:
Krzaczek, M.
Tejchman, J
Powiązania:
https://bibliotekanauki.pl/articles/231320.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
budynek mieszkalny
jakość powietrza wewnętrznego
stężenie CO2
komfort cieplny
CFD
strefa oddychania osobista
obciążenie cieplne
wentylacja naturalna
residential building
indoor air quality
CO2 concentration
thermal comfort
personal breathing zone
heat load
natural ventilation
Opis:
The influence of the CO2 concentration in a local air zone in naturally ventilated residential houses on the residents’ behaviour was numerically investigated. A numerical two-dimensional CFD model of the indoor zone based on experiments performed by the authors was used. Different resident locations in the fluid domain and different inlet velocities imposed by wind were considered in simulations. The overall thermal comfort and IAQ indices were also calculated. The investigations results show that in contrast to the overall air quality, the local CO2 was strongly dependent upon the resident location, fresh air inlet velocity and ventilation system type.
Źródło:
Archives of Civil Engineering; 2014, 60, 1; 91-121
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of road traffic on indoor air quality
Wpływ ruchu drogowego na jakość powietrza wewnętrznego
Autorzy:
Zender-Świercz, Ewa
Polański, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2174677.pdf
Data publikacji:
2022
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
particulate matter PM2.5
particulate matter PM10
Indoor Air Quality
road traffic
pyły zawieszone PM2.5
pyły zawieszone PM10
jakość powietrza wewnętrznego
ruch drogowy
Opis:
The quality of air that people breathe has become a very important parameter of quality of life. Pollution contributes to numerous diseases, problems with the absorption of knowledge, and also reduces work efficiency. The article attempts to find the relationship between road traffic and indoor air quality. The parameter used to assess air pollution was particulate matter (smog). The research was carried out in three localisations with different traffic volumes, in three places for each localisation, in the summer, autumn, and winter periods. It was found that in areas with heavy road traffic, this traffic causes an inflow of pollutants into the rooms. In low-traffic localisations, sources other than road traffic have a greater impact on the indoor air quality, especially in the cool periods (autumn, and winter)
Jakość powietrza, jakim oddycha człowiek, stała się bardzo istotnym parametrem jakości życia. Zanieczyszczenia przyczyniają się do licznych zachorowań, problemów z przyswajaniem wiedzy, a także obniżają wydajność pracy. W artykule podjęto próbę odnalezienia zależności pomiędzy natężeniem ruchu drogowego i jakością powietrza wewnętrznego. Parametrem, który wykorzystano do oceny zanieczyszczenia powietrza, był pył zawieszony (smog). Badania przeprowadzono w trzech lokalizacjach o różnym natężeniu ruchu, w trzech miejscach dla każdej lokalizacji, w okresach lato, jesień i zima. Stwierdzono, że w lokalizacji o dużym natężeniu ruchu pojazdów ruch ten powoduje napływ zanieczyszczeń do pomieszczeń. W lokalizacjach o małym natężeniu ruchu większy wpływ na jakość powietrza wewnętrznego mają inne niż ruch drogowy źródła, szczególnie w okresach chłodnych (jesień, zima).
Źródło:
Structure and Environment; 2022, 14, 4; 142--152
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza jakości powietrza wewnętrznego w małym przedszkolu
Analysis of indoor air quality in a small kindergarten
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/271034.pdf
Data publikacji:
2010
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
wentylacja
jakość powietrza
przedszkola
ventilation
air quality
kindergarten
Opis:
Najczęściej w przedszkolach człowiek zaczyna swoją edukację. Dzieci spędzają w nich od pięciu do dziesięciu godzin dziennie. Dlatego ważna jest jakość powietrza wewnętrznego. Najczęściej stosowanym systemem wentylacji w przedszkolach jest wentylacja naturalna. Dokładniej wentylacja grawitacyjna kanałowa wspomagana okresowym wietrzeniem. W badanym przedszkolu rano stężenie dwutlenku węgla nie przekracza dopuszczalnych norm. Po południu stężenia dwutlenku węgla są znacznie przekroczone - maksymalnie o 190%. Temperatura i wilgotność powietrza znajdują się w granicach normy. Rozszczelniając lub otwierając okna doprowadzamy do pomieszczeń powietrze zewnętrzne, poprawiamy w ten sposób działanie wentylacji grawitacyjnej, poprawiamy jakość powietrza wewnętrznego.
Formal education usually begins in kindergarten. Children spend five to ten hours a day there, so indoor air quality is of paramount importance. Natural ventilation (or to be more precise gravitational channel ventilation system) is by far the most common ventilation method in kindergartens; its efficiency is enhanced by airing the premises from time to time. In the kindergarten in question, carbon dioxide concentration in the morning does not exceed the permissible level. In the afternoon, however, this level is considerably exceeded (by as much as 190%). Temperature and humidity stay within the acceptable range of values. Thanks to unsealing or opening the windows, outdoor air penetrates into the rooms, which boosts the functioning of the gravitational ventilation system thus improving indoor air quality.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2010, 15, 2; 9-14
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ adsorpcji zanieczyszczeń na jakość powietrza w pomieszczeniach
Influence of pollutants adsorption on indoor air quality
Autorzy:
Sowa, J.
Powiązania:
https://bibliotekanauki.pl/articles/362724.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
jakość powietrza
adsorpcja
modelowanie
węgiel aktywny
air quality
adsorption
modeling
activated carbon
Opis:
W wielu przypadkach ograniczenie się jedynie do procesów adwektywnych przy modelowaniu jakości powietrza prowadzi do znacznych błędów. W artykule przedstawiono podstawowe zależności uproszczonego modułu adsorpcji, który mogły być stosowany z klasycznymi modelami jakości powietrza w skali makro. Przeanalizowano także wpływ adsorp- cji zanieczyszczeń powietrza na stężenia zanieczyszczeń dla hipotetycznego pomieszczenia biurowego przy różnych założeniach. Na podstawie przeprowadzonych analiz, a także na podstawie badań literaturowych, przestawiono uwagi odnośnie wpływu adsorpcji zanieczyszczeń na jakość powietrza w pomieszczeniach.
In many cases limitation just to advective processes during modelling indoor air quality leads to substantial errors. The paper presents basic relations of simplified adsorption model, that could be applied together with classic indoor air quality models of macro scale. The behaviour of hypothetical office has been analysed for different combination of assumptions. On the base of both performed analysis and literature studies some qualitative remarks have been formulated.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 251-254
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologiczna jakości powietrza w zakładach piekarniczych
The assessment of microbiological indoor air quality in bakeries
Autorzy:
Wołejko, E.
Kowaluk-Krupa, A.
Wydro, U.
Butarewicz, A.
Jabłońska-Trypuć, A.
Piekut, J.
Dec, D.
Łoboda, T.
Powiązania:
https://bibliotekanauki.pl/articles/399933.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
piekarnie
bakterie
grzyby
zanieczyszczenie powietrza
bacteria
fungi
indoor air quality
bakeries
Opis:
Celem niniejszej pracy była ocena stanu jakości mikrobiologicznej powietrza w zakładach piekarniczych zlokalizowanych na terenie województwa podlaskiego. Badania wykonano jesienią 2014 roku na terenie trzech zakładów piekarniczych. Próby powietrza pobierano metodą zderzeniową z użyciem próbnika powietrza MAS-100 (Merck, Niemcy). Mikrobiologiczne badania powietrza obejmowały oznaczenie ogólnej liczby bakterii psychrofilnych i mezofilnych, bakterii wskaźnikowych tj. bakterii z gatunku Pseudomonas fluorescens, gronkowców mannitolododatnich i manitoloujemnych oraz grzybów pleśniowych znajdujących się w powietrzu atmosferycznym. Zanieczyszczenie powietrza wewnętrznego w badanych piekarniach pod kątem mikrobiologicznym różniło się w zależności od rodzaju lokalizacji zakładu produkcyjnego. Stężenia występujących wewnątrz zakładów bakterii mezofilnych i Staphylococcus mannitolododatnich oraz mannitoloujemnych przekraczały wartości graniczne określone dla powietrza niezanieczyszczonego. Nie odnotowano natomiast w analizowanych piekarniach nadmiernego zanieczyszczania powietrza grzybami pleśniowymi. Najwyższą liczbę grzybów w powietrzu wykryto w piekarni 1, natomiast w pozostałych piekarniach ich liczba utrzymywała się na poziomie czystego powietrza atmosferycznego.
The aim of this study was to assess microbiological indoor air quality of selected bakeries located in the region of Podlasie. The microbiological studies were conducted in autumn in 2014 in three selected bakeries. Microbiological air counts were measured by impaction using an air sampler MAS-100 NT. The microbiological air studies, comprised the determination of the total number of psychrophilic and mesophilic bacteria, namely indicator bacteria such as: bacteria of the species Pseudomonas fluorescens, mannitol-positive and mannitol-negative Staphylococc, the total number of bacteria from the Enterobacteriaceae family and fungi found in atmospheric air. The results of the study of indoor air polluted with the analyzed groups of microorganisms differed depending on the type of test air and the location of the manufacturing plant. In the plants, the concentration of mesophilic bacteria and mannitol–positive and mannitol-negative Staphylococcus exceeded the limit values of unpolluted air, according to the Polish Standard recommendations.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 182-188
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klasyfikacja jakości powietrza wewnętrznego z zastosowaniem logiki rozmytej
CLASSIFICATION OF INDOOR AIR QUALITY USING FUZZY LOGIC
Autorzy:
SZCZUREK, Andrzej
MACIEJEWSKA, Monika
Powiązania:
https://bibliotekanauki.pl/chapters/1965450.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Opis:
Jakość powietrza wewnętrznego (IAQ) charakteryzuje fizyczny, chemiczny oraz biologiczny stan powietrza w pewnym miejscu i czasie. Informacja o niej jest bardzo potrzebna. Wielkość ta nie jest jednak mierzalna instrumentalnie w sposób bezpośredni. Jedną z możliwości określenia IAQ jest wykorzystanie modelu jej zależności od innych mierzalnych wielkości. W tej pracy rozważono możliwość zastosowania logiki rozmytej do klasyfikacji jakości powietrza wewnętrznego. Klasyfikację przeprowadzono na podstawie trzech paramentów powietrza wewnętrznego: temperatury, wilgotności względnej i stężenia ditlenku węgla. Model rozmyty wykorzystuje wiedzę ekspercką o związku między tymi parametrami a odczuciami człowieka. Porównano wyniki uzyskane z wykorzystaniem modeli bazujących na logice klasycznej i na logice rozmytej. W tym celu wykorzystano dane z monitoringu powietrza w przykładowym pomieszczeniu. Z przedstawionych rezultatów i ich dyskusji wynika, że zastosowana metoda jest dobrą propozycją rozwiązania problemu klasyfikacji jakości powietrza wewnętrznego.
Indoor air quality (IAQ) characterizes physical, chemical and biological state of air in a defined location and time. This quantity is not measurable with analytical methods. One of alternative approaches applied for its determination utilizes the fact that IAQ depends on many factors and those dependencies may be modelled. In this work we considered application of fuzzy logic to the classification of indoor air quality. The classification was carried out based on three parameters: temperature, relative humidity and carbon dioxide concentration. Fuzzy model utilized an expert knowledge about the relationship between these factors and human perception of the conditions around him. We compared results of classification obtained with classical, binary logic and fuzzy logic. Air monitoring data from an exemplary room was utilized for this purpose. Based on the presented results and their discussion, the applied method is an interesting option for solving a problem of indoor air quality classification.
Źródło:
Powietrze atmosferyczne. Jakość – zagrożenia – ochrona; 281-289
9788374939423
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Biophilic Installations for Indoor Air Quality Improvement
Wykorzystanie instalacji biofilicznych do poprawy jakości powietrza wewnętrznego
Autorzy:
Staszowska, Amelia
Powiązania:
https://bibliotekanauki.pl/articles/1811733.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
indoor air quality
biophilic installation
phytoremediation
green walls
jakość powietrza wewnętrznego
instalacje biofiliczne
fitoremediacja
zielone ściany
Opis:
This paper discusses the possibilities and limitations of using biophilic installations to improve the indoor air quality in residential and commercial spaces. Modular plant systems can provide the support or, in smaller facilities, even an alternative to the conventional indoor air purification techniques, such as filtration. The unquestionable advantage of green walls is their comprehensive influence on the indoor air quality by shaping both appropriate thermal and humidity conditions as well as the chemical air composition. However, these constructions are not mechanical systems and therefore, the effectiveness of these specific types of living air purifiers in removing gaseous pollutants and particulate matter cannot be expected to match the level of traditional systems.
W pracy omówiono możliwości i ograniczenia wykorzystania instalacji biofilicznych do poprawy jakości powietrza wewnętrznego w przestrzeniach mieszkalnych i komercyjnych. Roślinne systemy modułowe mogą stanowić wsparcie lub w mniejszych obiektach alternatywę dla konwencjonalnych technik oczyszczania powietrza wewnętrznego jakim jest filtracja. Niekwestionowaną zaletą zielonych ścian jest ich kompleksowy wpływ na jakość powietrza wewnętrznego poprzez kształtowanie zarówno odpowiednich warunków cieplno-wilgotnościowych jaki i składu chemicznego powietrza. Nie są to jednak układy mechaniczne i nie można oczekiwać, aby te swoistego rodzaju żywe oczyszczacze powietrza osiągały skuteczności w usuwaniu zanieczyszczeń gazowych i pyłowych na poziomie tradycyjnych systemów.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 716-726
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ tlenków azotu na jakość powietrza w pomieszczeniach
Impact of nitrogen oxides on the indoor air quality
Autorzy:
Bieniek, M.
Powiązania:
https://bibliotekanauki.pl/articles/340741.pdf
Data publikacji:
2008
Wydawca:
Główny Instytut Górnictwa
Tematy:
tlenki azotu
IAQ
jakość powietrza
zanieczyszczenia powietrza
nitrogen oxides
air quality
atmospheric pollutants emission
Opis:
Z uwagi na fakt, że przeważająca większość ludzi spędza około 70% czasu w pomieszczeniach (budynkach mieszkalnych, pomieszczeniach pracy i nauki, obiektach handlowych), konieczna jest ich ochrona przed bezpośrednim wpływem zmiennych zewnętrznych warunków klimatycznych, a także zapewnienie poczucia względnego komfortu przebywania, warunkowane stworzeniem właściwego mikroklimatu pomieszczenia IAQ (Indoor Air Quality). Dominujący wpływ na jakość powietrza wewnątrz budynków mają powstające w pomieszczeniach wentylowanych zanieczyszczenia. Ich źródłem są użytkownicy pomieszczeń oraz urządzenia stanowiące wyposażenie pomieszczeń, a także materiały budowlane użyte do wykończenia wnętrza (farby, lakiery, dywany, wykładziny syntetyczne). Odrębną grupę stanowią zanieczyszczenia wprowadzane do pomieszczeń wraz z powietrzem zewnętrznym, przy czym za zanieczyszczenie powietrza uważa się każdy jego składnik, który powoduje odstępstwa od klasycznego składu powietrza atmosferycznego. Do zanieczysz-czeń powietrza atmosferycznego zalicza się więc związki zawarte w spalinach, pyłki roślin, parę wodną, ale także jego naturalne składniki (O2, N2, CO2), jeżeli ich udział w powietrzu zewnętrznym jest różny od określonego dla klasycznego składu powietrza. Badania przeprowadzone przez amerykańską Agencję Ochrony Środowiska (???) wykazały, że w powietrzu wewnętrznym stężenia wielu zanieczyszczeń mogą być kilka razy większe niż w powietrzu zewnętrznym. Obowiązujące w Polsce przepisy prawne nie poruszają problemu jakości powietrza wewnątrz pomieszczeń, dotyczą jedynie wymaganej ilości powietrza wentylacyjnego i dopuszczalnych wartości stężeń substancji zanieczyszczających. Bardziej szczegółowo opracowano normy stężeń zanieczyszczeń na stanowiskach pracy, w których wyszczególniono dopuszczalne wartości normatywne dla 352 substancji chemicznych i 17 rodzajów pyłów, podczas gdy w przepisach dotyczących pomieszczeń przeznaczonych na stały pobyt ludzi wzięto pod uwagę jedynie 35 substancji zanieczyszczających. Ustawodawca pominął wiele zanieczyszczeń, co do których obecności i negatywnego wpływu na użytkowników pomieszczeń mieszkalnych nie ma wątpliwości, jak np. dwutlenek azotu. Postanowiono więc przybliżyć tę problematykę. Podjęto badania w celu określenia wpływu tlenków azotu na jakość powietrza w pomieszczeniach. Ich wyniki zostały omówione w niniejszym artykule.
Due to the fact, that predominantly most people spend ca. 70% of time indoors (dwelling buildings, rooms for work and learning, trade objects), their protection is necessary against direct changing of external climatic conditions. And also assuring of feeling of relative comfort of habitation conditioned by creation of proper indoor microclimate IAQ (Indoor Air Quality). Pollution arising in ventilated rooms has predominant impact on the indoor air quality. Its source are users of rooms as well as devices being equipment of rooms, and also building materials used to finish interior (paints, varnishes, carpets, synthetic facings). A separate group form the pollutants introduced to rooms together with an external air, and each component, which causes departures from classic composition of atmospheric air, is considered as a pollutant. Therefore, compounds contained in fumes, pollens of plants, water vapor are classified to be atmospheric air pollutants, but also its natural components (O2, N2, CO2), if their part in the external air differs from defined for classic composition of air. Researches conducted by U.S. Environmental Protection Agency (EPA) showed that concentrations of many pollutants in the indoor air could be few times higher than in the outdoor air. Legal regulations valid in Poland do not refer to the problem of indoor air quality, and concern required quantities of ventilating air and admissible values of polluting substances concentrations only. In more details there were developed standards of pollutants' concentrations at working posts, where admissible standardized values were specified for 352 chemical substances and 17 kinds of dusts. Whereas, only 35 polluting substances were taken into account in regulations related to rooms designed for permanent stay of people. Legislator skipped many contaminants, which presence and negative impact on users of habitable rooms is undoubted, e.g. nitrogen dioxide. Therefore, it was decided to study closer these problems and to conduct researches in this area. In this connection, researches were undertaken to define the nitrogen oxides' impact on the indoor air quality. Their results were discussed in the present article.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2008, 2; 5-17
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perceived indoor air quality and psychosocial work environment in office, school and health care environments in Finland
Autorzy:
Tähtinen, Katja
Remes, Jouko
Karvala, Kirsi
Salmi, Kari
Lahtinen, Marjaana
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2116581.pdf
Data publikacji:
2020-06-16
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
Indoor Air Questionnaire
school
health care
perceived indoor environment
reference material
office
Opis:
ObjectivesThe study examined the extent and prevalence of perceived indoor environment-related (IE-related) symptoms environmental complaints and psychosocial work environmental factors in Finnish office, school and health care environments.Material and MethodsThe data were collected from non-industrial workplaces (N = 455) in 2011–2012 and 2015–2017 using the Finnish Institute of Occupational Health’s Indoor Air Questionnaire (IA Questionnaire). Suspicion of IE-related problems was reported in 59% of workplaces. The data consisted of 28 826 employees’ responses.ResultsThe employees reported symptoms and environmental discomfort in office environments less often than in school or health care environments. The most often reported IE-related complaints were stuffy air (39% of respondents), dry air (34%) and insufficient ventilation (33%). The most often reported symptoms were irritation of the nose (27% of respondents), irritation of the eyes (26%), and hoarse or dry throat (24%). The results showed differences between the perceived IE in office, school and health care environments.ConclusionsCompared to earlier findings, the most often perceived IE-related symptoms and complaints have increased in Finnish health care environments. The office employees’ perceptions of psychosocial work environment remained fairly unchanged whereas health care personnel more often assessed their psychosocial environment as positive compared to previous reports. Instead of exact reference values, comparing the results of IA Questionnaires with the distributions and mean values of the results of this study may be more informative for those striving to solve IE-related problems. The presented distribution and mean values of perceived symptoms, environmental complaints and psychosocial work environment might help to relate the results to other workplaces. This, in turn, might increase the understanding that IA Questionnaire results are influenced by many factors. The results presented can be used as new reference material when interpreting the results of IA Questionnaires in office, school and health care environments.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2020, 33, 4; 479-495
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza wewnętrznego w typowym przedszkolu w Białymstoku
Indoor air quality in a typical kindergarten in Bialystok
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403063.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
stężenie dwutlenku węgla
jakość powietrza wewnętrznego
air quality
kindergarten
Opis:
W przedszkolach dzieci spędzają od pięciu do dziesięciu godzin dziennie, dlatego ważna jest jakość powietrza w pomieszczeniach. Najczęściej stosowanym systemem wentylacji w przedszkolach jest wentylacja naturalna, a dokładniej wentylacja grawitacyjna kanałowa wspomagana okresowym wietrzeniem. W badanym przedszkolu stężenie dwutlenku węgla rano nie przekracza dopuszczalnych norm. Po południu stężenia dwutlenku węgla znacznie przekraczają normy – maksymalnie o 97%. Temperatura i wilgotność powietrza są w granicach normy. Rozszczelniając lub otwierając okna doprowadzamy do pomieszczeń powietrze zewnętrzne i poprawiamy w ten sposób działanie wentylacji grawitacyjnej, a przez to poprawiamy jakość powietrza wewnętrznego.
Formal education usually begins in kindergarten. Children spend five to ten hours a day there, so indoor air quality is of paramount importance. Natural ventilation (or to be more precise gravitational channel ventilation system) is by far the most common ventilation method in kindergartens; its efficiency is enhanced by airing the premises from time to time. In the kindergarten in question, carbon dioxide concentration in the morning does not exceed the permissible level. In the afternoon, however, this level is considerably exceeded (by as much as 97%). Temperature and humidity stay within the acceptable range of values. Thanks to unsealing or opening the windows, outdoor air penetrates into the rooms, which boosts the functioning of the gravitational ventilation system thus improving indoor air quality.
Źródło:
Budownictwo i Inżynieria Środowiska; 2012, 3, 1; 33-38
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy consumption, thermal comfort and indoor air quality assessment in a school building using three air-cooling systems
Autorzy:
Romero, María Jesús
Comino, Francisco
Ruiz de Adana, Manuel
Powiązania:
https://bibliotekanauki.pl/chapters/31233748.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
HVAC systems
classroom
thermal comfort
energy consumption
energy simulation
Opis:
Efficient air-cooling systems for hot climatic conditions, such as southern Europe, are required in the context of Nearly Zero Energy Buildings. Regenerative indirect evaporative coolers, RIEC, and desiccant regenerative indirect evaporative coolers, DRIEC, could be considered an innovative alternative to direct expansion conventional systems, DX. The main objective of this work was to evaluate the seasonal performance of three air-cooling systems in terms of thermal comfort, air quality and energy consumption in a standard classroom. Several energy simulations were carried out to evaluate these indexes in the climate zone of Lampedusa, in Mediterranean area, by using European Standards. The simulations were based on experimentally validated models. DRIEC system was the recommended system to serve a standard classroom in terms of thermal comfort and RIEC system in terms of air quality and energy consumption. DX system achieved similar comfort favourable conditions to DRIEC system. However, it always worked in III unfavourable category of air quality and consumed three times more than RIEC and DRIEC systems.
Źródło:
Innovations – Sustainability – Modernity – Openness. Modernity in engineering; 115-121
9788366391901
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Case Study of the PM2.5 and PM10 Local Elimination Device – The Impact on Indoor Air Quality
Autorzy:
Szatyłowicz, Ewa
Siemiończyk, Emilia
Hawrylik, Eliza
Powiązania:
https://bibliotekanauki.pl/articles/24201765.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
air protection
air purification
particulate matter
PM2.5
PM10
Opis:
Due to its irritating, allergenic, toxic, pathogenic, and carcinogenic effects, suspended particulate matter (PM) seriously threatens human health. Therefore, it seems obvious to control the level of concentration of PM2.5 and PM10 particles and their reduction in the indoor environment such as homes, workplaces, or public utilities. In the following work, an attempt was made to determine the efficiency of a home air purifier based on the concentration of PM2.5 and PM10 particles at selected measurement points in a teaching room located in the building of the Bialystok University of Technology. The tests were carried out in March and in April 2021, using the DT-96 meter, which measured the concentration of PM2.5 and PM10 in the air. The study included the time and intensity of air purifier operation. In addition, reference was made to the concentration of PM2.5 and PM10 in outdoor air, which was measured at measuring stations in the city of Bialystok. The obtained test results made it possible to assess the initial state of air quality in the test room, as well as to determine the parameters affecting the best efficiency of the air purifier and to notice the dependencies in changes in the concentration of PM2.5 and PM10 between the indoor and outdoor environment.
Źródło:
Journal of Ecological Engineering; 2023, 24, 5; 32--39
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in a Selected Health Resort Facility: Analysis of PM10, PM2.5 and 222Rn Concentrations
Autorzy:
Merenda, Beata
Maciejewski, Piotr
Bezyk, Yaroslav
Sówka, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/2202169.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
health resort
indoor air
particulate matter
PM
222Rn
Opis:
This paper discusses the importance of indoor air quality and indicates its relation with outdoor air quality in the area of spa treatment. Significant factors and sources causing indoor air pollution by particulate matter and radon are considered. Particular attention is drawn to specific functions of health resorts in spa treatment in the context of the importance of indoor and outdoor air for patients staying in the resorts. It is underlined the specificity of health resorts providing treatment for patients classified as the group most sensitive to air pollution, i.e. people with chronic respiratory diseases. The study comprised measurements of 24-h concentrations of PM10, PM2.5 and 10-minute instantaneous concentrations of radon-222 (222Rn) from February 5 to February 25, 2021 in a treatment room of one of the Polish spas located in Lower Silesia. The analysis of interactions between the concentrations of two fractions of particulates PM10 and PM2.5 was presented. The interaction and dependence of factors affecting the elevated values of concentrations of the studied pollutants were discussed. The presented analyses showed that the concentrations of the studied pollutants were influenced by air exchange and air infiltration from outside to inside. In the case of short-term measurements of 222Rn activity concentration in the air, it was found that the observed changes in hourly concentrations of 222Rn are analogous to those observed in residential buildings. For the specific time intervals, the variation of PM concentrations and 222Rn activity concentration was found to be similar.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 202--215
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photodegradation of Lower Polybrominated Diphenyl Ether Congeners in Indoor Air – Model Studies
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124336.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PBDEs
indoor air quality
flame retardants
photolytic degradation
Opis:
Polybrominated diphenyl ethers (PBDEs) are additive flame retardants which have found applications in polymers for many consumer plastic and electronic goods. Wide use of these chemicals has led to their extremely high concentrations in the indor environments. This paper presents an exploratory study of the photodebromination of five individual lower polybrominated diphenyl ether congeners (BDE-28, BDE-47, BDE-99, BDE-100 and BDE-101) irradiated with white light and different UV (A, B, C) light ranges. The capability of photodegradation of lower PBDEs under room lights was proven by the debromination which occurred with various effectiveness for the selected PBDE congeners and depended of light source. Almost all PBDE congeners showed the greatest decay when exposed to UV-C, with the exception of BDE-100. The decay of irradiated congeners occurred rapidly during the first 5 min of experiment. The final degradation varied from 38% decay (BDE-28, UV-C) to 94% (BDE-47, UV-C). These findings can help in predicting PBDE behavior in indoors and also be useful in the design of PBDE remediation processes.
Źródło:
Journal of Ecological Engineering; 2017, 18, 3; 180-186
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwość poprawy jakości powietrza w polskich szkołach w wyniku modernizacji opartej na zasadach zrównoważonego rozwoju
Autorzy:
Sowa, J.
Panek, A.
Powiązania:
https://bibliotekanauki.pl/articles/362510.pdf
Data publikacji:
2005
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
jakość powietrza wewnętrznego
zasada zrównoważonego rozwoju
indoor air quality
Opis:
The paper describes part of the results of the Polish/Norwegian scientific cooperation within the project SUREBUILD, funded by the Norwegian Ministry of Foreign Affairs. The whole project is devoted to sustainable redevelopment of buildings in Poland, but special attention was paid to Polish schools constructed between 1958-1966 (the "Millenium" schools). Potential technologies for sustainable modernization of Polish schools were analyzed taking into consideration energetic, environmental, economic and other related criterions. Substantial part of the work was devoted to fin d the economically feasible technologies that might improve current unsatisfactory level of indoor air quality in Polish schools. The paper presents general recommendations for the moderniza- tion of ventilation system s in Polish schools as well as describes the technologies selected for school in Zgierz, the case study object of the project.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2005, T. 1; 305-314
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacterial and Fungal Aerosols in Air-Conditioned Office Buildings in Warsaw, Poland—The Winter Season
Autorzy:
Gołofit-Szymczak, M.
Górny, R. L.
Powiązania:
https://bibliotekanauki.pl/articles/90052.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
indoor air quality
office buildings
bacterial and fungal aerosols
size distribution
Opis:
The microbial quality of the working environment was assessed in winter in air-conditioned office buildings in Warsaw. The average indoor concentrations of bacterial and fungal aerosols were low (<103 cfu∙m–3), below Polish proposals for threshold limit values in public service buildings. Even during cold months, if the air-conditioning system works properly, people remain the main source of bacterial aerosol in offices, whereas infiltration of outdoor air remains a major mechanism responsible for their fungal contamination. An analysis of the bioaerosol size distribution showed that microbial propagules that reach both the upper and lower respiratory tract may evoke numerous adverse health effects from irritation and asthmatic reactions to allergic inflammation. A comparative analysis of viable and total airborne microbial counts showed that viable micro-organisms accounted for up to 0.3% of the total number of microbial propagules. Hence, a comprehensive hygienic assessment of office workplaces should include an efficient control of both these elements.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 4; 465-476
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of integrated indoor environmental air quality parameters in selected church buildings of Faisalabad city: a statistical based comparative study
Autorzy:
Hussain, Zahid
Khan, Mohammad S.
Kundi, Kundi
Alaf, Kashif
Ullah, Yasir
Powiązania:
https://bibliotekanauki.pl/articles/35518580.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
indoor air quality
church buildings
particulate matter
public health
air pollution
Opis:
The objective of this study is to control the air quality parameters for a selected range of different particulate matters. A comprehensive experimental approach is established to regulate the quality of air about a selected range of different air pollutants being investigated in the indoor atmosphere of the church building. Relative humidity, temperature, carbon dioxide, particulate matter and radon were considered as the factors of air quality extents. For establishing the association among the selected parameters, the data were mathematically analyzed. The correlation coefficient confirmed a strong relationship between the indoor CO2 level and the number of public. A negative relationship between the indoor CO2 extent and indoor temperature confirmed that due to the increase in temperature the concentration of CO2 decreased as well. A solid adverse connection among indoor relative humidity and indoor air temperature showed that due to the increase in air temperature, the level of the relative humidity decreased. Some recommendations were proposed for the treatment of air quality in church buildings for human well-being.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 134-147
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ błędów termomodernizacyjnych budynków użyteczności publicznej na poziom jakości powietrza wewnętrznego
Impact of thermomodernisation errors of public buildings on the level of indoor air quality
Autorzy:
Janka, R.M.
Powiązania:
https://bibliotekanauki.pl/articles/402978.pdf
Data publikacji:
2016
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
jakość powietrza wewnętrznego
stężenie ditlenku węgla
wentylacja
szybkość zmian stężenia CO2
indoor air quality
concentration of carbon dioxide
ventilation
rate of change of CO2 concentration
Opis:
Remonty obiektów użyteczności publicznej, a szczególnie budynków zabytkowych, powinny zapewniać, nie tylko poprawę ich stanu technicznego i obniżenie energochłonności, ale także stwarzać warunki do występowania w nich odpowiedniego poziom jakości powietrza wewnętrznego. W artykule przedstawiono wyniki badań wpływu zakresu modernizacji obiektów, obciążenia osobowego, czasu przebywania osób w pomieszczenia oraz kubatury sal i rodzaju stosowanego systemu wentylacji naturalnej i mechanicznej na przebieg, a także szybkość zmian stężenia ditlenku węgla w powietrzu wewnętrznym. Badania te przeprowadzono w ośmiu pomieszczeniach zarówno administracyjnych, jak i audytoryjnych o różnej wielkości i przeznaczeniu w dwóch wyremontowanych XIX budynkach użyteczności publicznej. Zagadnie to powiązano z badaniami zmian wilgotności i temperatury powietrza. Wykazano, że przy dużym obciążeniu osobowym sal już po około 40-50 minutach, maksymalnie 1,5 godziny w powietrzu wewnętrznym występuje stężenie ditlenku węgla ponad dwu i trzy krotnie wyższe od poziom progu higienicznego CO2.
Renovation of public buildings, especially historic buildings, should ensure not only improve their condition and reduce the energy consumption, but also the appropriate level of indoor air quality. Inserting in the hallways of public buildings fire partitions without at the same time ensuring an adequate level of air exchange affects the deterioration of indoor air quality at these facilities. They arise areas where there is inadequate quality of indoor air. Air that they breathe, both employees of the institution taking up very often important decisions and the clients of these offices. The article presents a study on the impact of the scope of the modernization of selected public facilities, passenger load, the residence time of the meeting room and the volume and the type of ventilation system on the course and speed of changes in the concentration of carbon dioxide in the indoor air. These studies were conducted in eight areas both administrative and auditoriums of different sizes and purposes in two renovated nineteenth century public buildings. These buildings are the seats of the courts. This issue is related to research changes in humidity and air temperature. It has been shown that under high load passenger rooms after about 40-50 minutes up to 1.5 hours in the indoor air concentration of carbon dioxide is over two and three times higher than the threshold level of the sanitary CO2.
Źródło:
Budownictwo i Inżynieria Środowiska; 2016, 7, 4; 17-27
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu środowiska wewnętrznego w wybranych przedszkolach. Cz. 1 Temperatura
Analysis of indoor environment in a kindergarten building. P. 1 Temperature
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403027.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
jakość powietrza wewnętrznego
wentylacja
mikroklimat
temperatura
indoor air quality
ventilation
microclimate
temperature
Opis:
Aby zapewnić dzieciom odpowiednie warunki sanitarno-higieniczne w pomieszczeniach przedszkolnych należy pamiętać o częstym wietrzeniu i nie przegrzewaniu pomieszczeń. Aby zapewnić dzieciom odpowiednie warunki sanitarno-higieniczne w pomieszczeniach należy więc zapewnić właściwą wentylację. Temperatura w pomieszczeniach jest parametrem stanu powietrza najbardziej odczuwalnym przez ludzi. Decyduje ona o samopoczuciu, wydajności w pracy, zapewnia tzw. komfort cieplny. Niewłaściwa temperatura, może doprowadzić do chorób. Badania prowadzono w trzech przedszkolach o różnej wielkości i różnej termoizolacyjności ścian zewnętrznych. Termomodernizację w poszczególnych przedszkolach wykonano w różnym czasie. Prowadzono badania jakości powietrza wewnętrznego w salach przedszkolnych. W artykule przedstawiono tylko wyniki dotyczące temperatury powietrza wewnętrznego badanych przedszkoli.
In order to ensure proper sanitary and hygienic conditions in a kindergarten building, one needs to remember about airing the rooms frequently and making sure that the temperature is not too high; this is why an efficient ventilation system is indispensable. Temperature is the parameter of indoor air whose influence people are most likely to feel. It is the decisive factor about their general physical and mental state and the efficiency of their work; temperature also ensures the socalled thermal comfort. A temperature that is either too high or too low may cause various diseases. The research was conducted in three kindergartens which varied in terms of the space of the facilities and thermal insulation of exterior walls. Thermomodernization in each kindergarten was carried out at a different time. The research focused on the quality of indoor air in particular rooms. This article discusses the results only with regard to air temperature in the kindergartens in question.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 4; 281-285
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry powietrza podczas pracy lakierni autobusowej na wybranym przykładzie
Air quality parameters during the operation of a bus paint shop on the basis of a selected example
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/315602.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
wentylacja
lakiernik
jakość powietrza wewnętrznego
ventilation
car paint shop
indoor air quality
Opis:
Zasadniczą treść tego artykułu stanowi przedstawienie parametrów powietrza wentylacyjnego, które wystąpiły podczas ich pomiarów, przeprowadzonych w czasie pracy lakierni autobusowej. Przedstawiono rozkłady temperatur, wilgotności względnej, prędkości ruchu powietrza w lakierni oraz stężenia dwutlenku węgla, a także wyciągnięto wnioski z wyników pomiarów. Omówiono także zagadnienia, związane z komfortem cieplnym oraz jego wpływem na warunki pracy pracownika w lakierni. Szczególny nacisk położono na scharakteryzowanie wpływu dwutlenku węgla na organizm ludzki. Zawarto również informacje o dopuszczalnych wartościach tego trującego gazu w pomieszczeniach lakierni, wynikające z obowiązujących przepisów.
The principal part of this paper is concerned with the presentation of air quality parameters and ventilation rates, which were registered during measurements conducted in a bus paint shop. The presentation includes the distribution of temperatures, relative humidity, velocity of air circulation in a paint ship along with concentration of carbon dioxide coupled with conclusions from the conducted measurements. In addition, the presentation includes the issues associated with thermal comfort and its impact on the working conditions in a paint shop. The paper also contains information regarding the maximum admissible levels of this pollutant on the premises of a paint shop, according to the regulations in force.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 199-203, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozkład wybranych parametrów powietrza w hamowni samochodowej
Variability of selected air parameters in the premises containing a car dynamometer
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/315419.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
jakość powietrza wewnętrznego
dwutlenek węgla
hamownia
indoor air quality
carbon dioxide
car dynamometer
Opis:
W artykule scharakteryzowano pracę hamowni samochodowych omawiając szczegółowo ich rodzaje i przeznaczenie. Wskazano między innymi na warunki pracy w pomieszczeniach, w których znajdują się tego typu urządzenia diagnostyczne. Przedstawiono także podstawowe informacje o komforcie cieplnym, jaki należy stworzyć diagnostom realizującym swoje zadania w hamowni. Duży nacisk położono na omówienie szkodliwości występowania nadmiernego stężenia CO2 w pomieszczeniach i jego wpływ na organizm ludzki. W części eksperymentalnej zawarto informacje o zmierzonych parametrach powietrza wewnętrznego w hamowni, takich jak temperatura, wilgotność względna i stężenie dwutlenku węgla. Uzyskane wyniki pozwoliły na wyciagnięcie wniosków z których wynika, że zaistniałe podczas pracy hamowni warunki powietrza w pomieszczeniu nie odbiegały znacząco od prawidłowych. Wskazano także na konieczność wykonania dalszych badań.
The paper discusses the operation of a car dynamometer and includes details of its types and the designated use. Among other things, the conditions of operation in the premises containing diagnostic devices are indicated. The basic information about the thermal comfort, which needs to be secured for the work of diagnosticians performing their duties in the premises containing a dynamometer. An emphasis is placed on the discussion of the hazard posed by the excessive CO2 concentrations in the premises and its effects on the human body. The experimental part of the paper contains information regarding the measured parameters of internal air in the rooms containing a dynamometer, such as temperature, relative humidity and carbon dioxide concentration. The results enabled the statement of the conclusions which indicate that the ambient air conditions in the premises do not differ significantly from the acceptable results. The need to conduct further studies is also indicated.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 204-208, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunki rozwoju pomiarów zapachu i zawartości związków mVOC we wnętrzach budynków
Trends in odour measurements and determining mVOC content in the interiors of buildings
Autorzy:
Kostyrko, K. B.
Kozicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/267570.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odorant
powietrze wewnętrzne
moc
indoor air quality
IAQ
microbial volatile organic compounds
mVOC
Opis:
Praca zawiera zestawienie współczesnych technik służących do pomiarów zapachu jak również dopuszczalnych poziomów stężeń substancji uciążliwych zapachowo występujących we wnętrzach budynków. Scharakteryzowano lotne związki organiczne pochodzenia mikrobiologicznego, odpowiedzialne za różnego rodzaju zapachy, jak również techniki analityczne służące do ich chemicznej charakterystyki. Szczególną uwagę poświęcono elektronicznym nosom, będącym coraz powszechniejszymi, często przenośnymi, urządzeniami służącymi do monitorowania stężenia odorantów zapewniającymi analizę w czasie rzeczywistym.
The work summarizes contemporary techniques for odour measurements as well as permissible levels of concentrations of odorous substances occurring in the interiors of buildings. Microbial volatile organic compounds which are responsible for various smells have been characterized. The most suitable techniques for sampling and MVOC chemical characterization in indoor environments were reviewed. The olfactometric techniques are discussed and the strong and weak points of odour assessment through human detection are highlighted. Particular attention was paid to electronic noses, which are increasingly common, often portable, devices for monitoring the concentration of odorants providing real-time analysis.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 97-102
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu środowiska wewnętrznego w wybranych przedszkolach. Cz. 2 Wilgotność względna
Analysis of indoor environment in a kindergarten building. P. 2
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403031.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
jakość powietrza wewnętrznego
wentylacja
mikroklimat
wilgotność względna
indoor air quality
ventilation
microclimate
relative humidity
Opis:
Najczęstszym objawem problemów z wymianą powietrza jest nadmierny wzrost wilgotności, który jest konsekwencją źle działającej wentylacji. Wilgotność względna powietrza w pomieszczeniu powinna się mieścić w granicach 30-65%, optymalna - 40-50%. Przebadano trzy przedszkola o różnej izolacyjności ścian zewnętrznych, aby ocenić stan środowiska wewnętrznego z uwzględnieniem wilgotności względnej. Badania wszystkich przedszkoli prowadzono w trzech seriach pomiarowych. Wilgotność powietrza w listopadzie i lutym, w budynkach po termomodernizacji, była poniżej zalecanych wartości. Powietrze było suche, mimo dużej wilgotności względnej powietrza zewnętrznego. W przedszkolu nie poddanym termomodernizacji, bez względu na porę roku, powietrze wewnętrzne było wilgotne.
Excessive rise of humidity is the most frequently observed sign of problems with air circulation, which often result from a faulty ventilation system. Relative humidity value indoors should range from 30% to 65%, the ideal being between 40% and 50%. The research was conducted in three kindergartens with different insulation of exterior walls; the objective was to assess the quality of indoor air with regard to relative humidity. Three series of measurements were taken in each of the kindergartens. In the building where thermomodernization was carried out, humidity values in February and November dropped below the recommended ones. Even though outdoor relative humidity was high, indoor air in this kindergarten was dry. In the kindergarten whose heating system has not been modernized, humidity values inside the building were appropriate regardless of the season.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 4; 287-291
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort in university computer laboratories
Komfort cieplny w pracowniach komputerowych uczelni wyższej
Autorzy:
Telejko, M.
Stachera, A.
Powiązania:
https://bibliotekanauki.pl/articles/402042.pdf
Data publikacji:
2018
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
PMV
PPD
microclimate
indoor air quality
komfort cieplny
mikroklimat
jakość powietrza wewnętrznego
Opis:
Thermal comfort defines the state of satisfaction of a person or a group of people with thermal conditions of the environment in which the person, or the group of people is staying. The state of satisfaction depends on the balance between the amount of heat produced by the organism in the process of metabolism and heat loss from the organism to the surrounding environment. It has an effect on the quality and efficiency at work, and indirectly also on the presence of symptoms of Sick Building Syndromes (SBS). Due to differences in body structure, metabolism, clothing etc., it is not possible to create a satisfactory thermal environment for all the people staying in it. However, there are parameter values, which maintained at an appropriate level, allow to meet thermal expectations of even 95% of people staying in this environment. The article presents the results of tests conducted in the university computer rooms. The studies included measurements and analysis of typical internal microclimate parameters: temperature, relative humidity and CO2 concentration. The results raised considerable reservations and therefore in order to assess fully the conditions of use, it has been decided to conduct evaluation of thermal comfort in rooms analysed. In addition, the surrounding surface radiation temperature and clothing insulation of users have been specified. On the basis of the obtained data, PPD and PMV index values were determined in accordance with the standard EN ISO 7730:2005 Ergonomics of the thermal environment – Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria [3].
Komfort cieplny określa stan zadowolenia osoby lub grupy osób z warunków termicznych środowiska, w którym osoba ta lub grupa osób przebywa. Ten stan zadowolenia zależny jest od równowagi pomiędzy ilością ciepła wytwarzanego przez organizm w procesie metabolizmu a stratami ciepła z organizmu do otaczającego go środowiska. Ma on wpływ na jakość i wydajność pracy, a pośrednio również na występowanie symptomów syndromów chorego budynku (SBS). Na skutek różnic w budowie ciała, metabolizmie, ubiorze etc. nie ma możliwości stworzenia środowiska cieplnego odpowiadającego wszystkim przebywającym w nim osobom. Istnieją jednak wartości parametrów, które utrzymane na odpowiednim poziomie, pozwalają na spełnienie oczekiwań termicznych nawet 95% ludzi przebywających w tym środowisku. W artykule zaprezentowano wyniki badań przeprowadzonych w pomieszczeniach komputerowych uczelni wyższej. Badania obejmowały pomiary oraz analizę typowych parametrów mikroklimatu wewnętrznego: temperatury, wilgotności względnej oraz stężenia CO2. Uzyskane wyniki budziły spore zastrzeżenia, dlatego w celu pełnej oceny warunków użytkowania zdecydowano się na przeprowadzenie oceny komfortu termicznego analizowanych pomieszczeń. Dodatkowo określono zatem temperaturę promieniowania powierzchni otaczających i izolacyjność odzieży użytkowników. Na podstawie otrzymanych danych wyznaczono wartości wskaźników PPD i PMV, zgodnie z normą EN ISO 7730:2005 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria [3].
Źródło:
Structure and Environment; 2018, 10, 3; 201-210
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort measurements in the Energis building
Badania komfortu cieplnego w budynku Energis
Autorzy:
Białek, Anita
Koltuk, Bade
Powiązania:
https://bibliotekanauki.pl/articles/2055091.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
indoor air quality
thermal comfort
thermal responses
jakość powietrza wewnętrznego
komfort cieplny
odczucia cieplne
Opis:
In the paper the measurements of thermal comfort in the modern smart building “Energis” have been presented together with their analysis. The data have been obtained in the spring and the analyses of indoor air parameters as well as subjective responses of the volunteers have been conducted. Based on the performed studies it has been concluded that the people felt fine in the considered room (pleasantly warm, cool and comfortable) and described their feelings as acceptable and comfortable.
W artykule przedstawiono wyniki badań i analizę komfortu cieplnego w budynku inteligentnym „Energis”. Dane eksperymentalne uzyskano w okresie wiosennym, a analiza dotyczyła parametrów powietrza wewnętrznego, jak również subiektywnych odczuć ochotników. W oparciu o przeprowadzone badania można stwierdzić, że użytkownicy czuli się dobrze w rozpatrywanym pomieszczeniu (przyjemnie ciepło i chłodno, a także komfortowo) i ocenili swoje odczucia jako akceptowalne i komfortowe.
Źródło:
Structure and Environment; 2021, 13, 1; 10--15
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenia ozonu w pomieszczeniach przeznaczonych na czasowy pobyt ludzi
Ozone concentrations in Lublin non-occupational environments
Autorzy:
Staszowska, A.
Dudzińska, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/127306.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ozon
powietrze wewnętrzne
jakość powietrza wewnętrznego
ozone
indoor air
indoor air quality
non-occupational environments
Opis:
Badania przeprowadzono w pomieszczeniach przeznaczonych na czasowy pobyt ludzi: w pokojach biurowych i punktach kserograficznych zlokalizowanych na terenie miasta Lublina. Badania stężenia ozonu w powietrzu wewnętrznym przeprowadzone zostały w dwóch okresach: w okresie letnim i w sezonie grzewczym. Próbki do badań pobierano metodą pasywną. Pomiaru stężenia ozonu dokonano metodą spektrofotometryczną. Stężenia ozonu dla okresu letniego wyniosły: 0,01 -K),04 mg/m3 dla pomieszczeń biurowych oraz 0,008+0,176 mg/m3 dla punktów kserograficznych. Natomiast w sezonie grzewczym stężenia ozonu kształtowały się w następujących przedziałach: 0,007+0,018 mg/m3 dla pomieszczeń biurowych i 0,001-K),015 mg/m3 dla punktów kserograficznych. W punktach kserograficznych dopuszczalne stężenie 0,15 mg/m3 zostało przekroczone w sezonie letnim w dwóch przypadkach. W sezonie grzewczym nie odnotowano przekroczenia dopuszczalnego stężenia w punktach kserograficznych. W przypadku pomieszczeń biurowych dopuszczalne stężenie wynoszące 0,15 mg/m3 nie zostało przekroczone.
Ozone is the common component of indoor air. Because of its high reactivity it plays an important role in forming of indoor air quality, which influence directly on health of interior occupants. It is a well-known fact, that ozone can damage the respiratory system, inflames and irritates respiratory tissues, and can worsen asthmatic symptoms in individuals with asthma. Ozone exposure can produce symptoms such as coughing, chest tightness and impaired breathing. Elevated exposures have the potential to induce permanent lung damage, and even increase the risk of premature death in persons with poor health. Hence, there is a need to measure the concentrations of ozone in indoor air environments. The indoor ozone concentration depends on the outdoor ozone concentrations, the rate at which indoor air is exchanged with outdoor air, interior air circulation, indoor sources of ozone (eg ozone generators, electrostatic air cleaners, photocopiers, and laser printers), the rate at which ozone is removed by indoor surfaces, and reactions between ozone and other chemicals in the air. The objective of this study was to examine ozone concentrations in indoor air in selected non-occupational environments: office rooms and Xerox service points. Summer time and cold (heating) season was examined. Samples were collected using passive method. The ozone concentration on summer time was within the range of 0.04-K).01 mg/m3 for office rooms and 0.008-0.176 mg/m3 for Xerox points. In two examined Xerox places the permitted level of ozone (0.15 mg/m3) was exceeded in summer time. In cold time the permitted level of ozone was not exceeded in any Xerox points. hi offices rooms the permitted level of ozone was not achieved.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 623-627
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort in intelligent buildings
Komfort cieplny w budynkach inteligentnych
Autorzy:
Majewski, G.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/402098.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
smart building
thermal comfort
indoor air quality
inteligentny budynek
komfort termiczny
jakość powietrza w pomieszczeniach
Opis:
The paper presents the issue of thermal comfort conditions with regard to intelligent buildings. First the principles of thermal comfort are discussed, namely the parameters affecting the human perception of the best indoor air conditions. Among the mentioned parameters indoor temperature seems to be especially vital for humans. In the second part the test results of temperature changes in the Energis building are presented together with the discussion.
Źródło:
Structure and Environment; 2016, 8, 1; 25-30
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacje wymiany powietrza, jako pomoc w projektowaniu organizacji napływu powietrza do mieszkań
Simulation analysis of indoor air quality, as a help in organization of airflow to the apartaments
Autorzy:
Miśniakiewcz, E
Powiązania:
https://bibliotekanauki.pl/articles/115224.pdf
Data publikacji:
2013
Wydawca:
Wyższa Szkoła Techniczna w Katowicach
Tematy:
wymiana powietrza
projektowanie architektoniczne
stolarka budowlana
symulacja komputerowa
model wielowarstwowy
air exchange
architecture design
window woodwork
computer simulation
multi-zone modeling
Opis:
W artykule przedstawiono podstawowe zależności opisujące zasadę działania systemu wentylacji naturalnej. Przedstawiono również wyniki symulacji wymiany powietrza w pomieszczeniach mieszkalnych wyposażonych w wentylację naturalną. Symulacje przeprowadzono autorską procedurą obliczeniową. Na podstawie analizy przeprowadzonych symulacji, zaproponowano wprowadzenie zróżnicowania stolarki okiennej, np. w odniesieniu do kondygnacji, dla utrzymania akceptowalnej jakości powietrza wewnętrznego w sezonie grzewczym. Przedstawiona propozycja zróżnicowania stolarki okiennej pod względem napływu powietrza do pomieszczeń kierowana jest głównie do projektantów architektury.
Paper presents basic rules describing function of natural ventilation system. It has been also presented a comparison of the simulation analysis selected results in the existing dwelling houses with natural ventilation. On the basic of performed simulation analysis introduction of various window types was proposed, e.g. depending on storey, for maintenance of accepted indoor air quality in the heating season. Presented proposition of diversity window woodwork types in respect of air inflow is addressed mostly to architecture designer.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach; 2013, 5; 75-85
2082-7016
2450-5552
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary test results of thermal comfort in a classroom
Wstępne wyniki badań komfortu cieplnego w sali lekcyjnej
Autorzy:
Krawczyk, Natalia
Piasta, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/402066.pdf
Data publikacji:
2019
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
indoor air quality
thermal sensations
komfort cieplny
jakość powietrza w pomieszczeniu
odczucia termiczne
Opis:
The paper presents the issue of thermal comfort based on the conducted study. First, the definition and importance of thermal comfort was discussed. Then, air parameters were measured and surveys were conducted regarding questions about the assessment of thermal comfort of persons using the room. The list of the subject thermal comfort evaluation tests are illustrated in the diagrams. The impact of gender and BMI on the Predicted Mean Vote PMV were also analyzed. In the next part, results obtained from surveys and according to formulas from the standard were developed, and then compared.
W pracy przedstawiono zagadnienie komfortu cieplnego w oparciu o przeprowadzone badanie. Najpierw omówiono definicję i znaczenie komfortu cieplnego. Następnie wykonano pomiary parametrów powietrza oraz przeprowadzono ankiety dotyczące pytań o ocenę komfortu cieplnego osób użytkujących pomieszczenie. Zestawienia badań oceny komfortu cieplnego zilustrowano na wykresach. Analizie poddano także wpływ płci i wskaźnika BMI na przewidywaną średnią ocenę PMV. W kolejnej części opracowano wyniki otrzymane z ankiet oraz według wzorów z normy, a następnie je porównano.
Źródło:
Structure and Environment; 2019, 11, 4; 281-286
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroorganizmy w kurzu z pomieszczeń na przykładzie miasta Lublina
Characterization of the microbial community in settled dust samples from indoor environments in Lublin
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126364.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikroorganizmy
powietrze wewnętrzne
kurz domowy
jakość powietrza wewnętrznego
microorganisms
indoor air
house dust
indoor air quality
Opis:
W pracy jest przedstawiona charakterystyka mikrobiologiczna próbek kurzu zebranych w pomieszczeniach mieszkalnych i placówkach edukacyjnych zlokalizowanych na obszarze miasta Lublina. W kurzu najczęściej spotykanymi bakteriami były pałeczki Gram-dodatnie. Większość należała do rodzaju Bacillus. W próbkach kurzu z placówek edukacyjnych największą koncentrację bakterii stanowił gatunek Bacillus subtillis. Największą grupę po pałeczkach Gram-dodatnich spotykanych w kurzu były ziarniaki Gram-dodatnie. Głównie był to rodzaj Micrococcus, a dominującym gatunkiem był Micrococcus luteus. W kurzu znajdywały się także Gram-dodatnie ziarniaki z rodzaju Staphylococcus oraz Gram-ujemne pałeczki. W przypadku grzybów zawartych w kurzu dominującymi rodzajami były Aspergillus (głównie gatunek Aspergillus nigerii) oraz Penicillium. Grzyb z rodzaju Cladosporium był także spotykany w badanych próbkach.
Dust particles collected from indoor environments may contain hundreds of chemically and biologically active components, which can cause many adverse health effects and deterioration of building materials. While all types of microorganisms can cause problems indoors, bacteria and fungi are most commonly associated with indoor air quality complaints. Some of them produce mucus and excrete chemicals which can provoke allergy, respiratory system and skin irritation, headache, or fatigue. This study was designed to obtain information about characterization of the microbial community in settled dust samples from indoor environments of the Lublin area. Dust samples were collected from households and educational establishments. Microbial species and their concentrations were determined by culture analysis. The concentrations and proportions of morphologically distinguishable culturable bacteria and fungi in dust samples was as follows. In case of bacteria the most commonly found were Gram-positive rods, predominantly Bacillus spp. (Bacillus subtillis) and cocci - genus Micrococcus (Micrococcus leutus) and Staphylococcus. Fungi were represented by genus Aspergillus (mainly Aspergillus nigerii), Penicillium, and Cladosporium. Additionally, microbial concentrations of similar environments vary between sample types, eg total amount of fungi has been higher in dust from textile covered floor than in samples from bare floor.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 325-328
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia wentylacji i jakości powietrza wewnętrznego w obliczu zagrożeń COVID-19. Współczesne problemy w kontekście historycznym
Selected ventilation and indoor air quality issues in the face of COVID-19
Autorzy:
Radziewicz-Winnicki, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/1848917.pdf
Data publikacji:
2021
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
architektura zrównoważona
wentylacja
jakość powietrza wewnętrznego
historia architektury
sustainable architecture
ventilation
indoor air quality
history of architecture
Opis:
Artykuł podejmuje polemikę na temat aktualnego stanu prawnego w dziedzinie wentylacji i jakości powietrza wewnętrznego w kontekście pandemii COVID-19. Obecne problemy związane z bezpieczeństwem sanitarnym, a także komfortem użytkowników skłaniają nas do konieczności korekty stosowanych założeń czy strategii. Pomocna wydawać się może analiza oraz próba implementacji rozwiązań stosowanych w architekturze historycznej. Konkluzją są wytyczne w kierunku działań na rzecz rozwiązania obecnych problemów, jak również uniknięcia przyszłych zagrożeń.
Contemporary problems in historical context. The article undertakes a polemic on the current state of legislation in the field of ventilation and indoor air quality in the context of the COVID-19 pandemic. Current problems of sanitary safety and comfort of users make it necessary to correct the assumptions and strategies used. It may seem helpful to analyze and try to implement solutions used in historical architecture. The conclusion is a guideline for actions towards solving current problems as well as avoiding future threats.
Źródło:
Builder; 2021, 25, 4; 15-17
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie parametrów powietrza w kotłowni opalanej różnymi rodzajami paliwa
Parameters of air fired boiler fed with different types of fuel
Autorzy:
Gładyszewska-Fiedoruk, K.
Rybałtowska, N.
Powiązania:
https://bibliotekanauki.pl/articles/400633.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
jakość powietrza wewnętrznego
tlenek węgla
dwutlenek węgla
kotłownia
indoor air quality
carbon monoxide
carbon dioxide
boiler
Opis:
W pracy podjęto próbę analizy wyników z przeprowadzonych pomiarów CO i CO2 w kotłowniach przydomowych. Przedstawiono stężenie spalin w trakcie energetycznego wykorzystania różnych rodzajów paliwa (olej opałowy lekki, pellet drzewny, ekogroszek, drewno brzozowe z węglem). Dało to możliwość oszacowania, które z badanych paliw daje najwyższą jakość powietrza w kotłowni podczas jego spalania, a tym samym najniższe stężenia badanych parametrów. Dodatkowo pozwoliło to dowieść, które paliwo w jakich warunkach spala się całkowicie i zupełnie, co oznacza, że wszystkie składniki paliwa uległy spaleniu do postaci ostatecznej i w spalinach nie ma już palnych cząstek. Analiza kosztów pozwoliła sprawdzić, jaki nośnik energii będzie najkorzystniejszy pod względem finansowym.
The measurement and interpretation of indoor carbon dioxide CO2 concentration can provide information on building indoor air quality and ventilation. On the other hand, concentration of carbon monoxide CO can show as how combustion process run and if the boiler is safe. When there is not sufficient air available to complete the combustion process, some of the fuel is left unburned, resulting in inefficiency and undesirable emissions. An examination of the CO2 and CO concentration in boiler and interpretation results help to improve indoor air quality. The paper presents characteristics of concentration CO2 and CO depend on used fuel in tested boiler rooms. The concentration curves show how each fuel combustion affect the amount of CO2 and CO that is produced.
Źródło:
Inżynieria Ekologiczna; 2016, 49; 202-207
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Filtration and Sterilization in Ventilation Systems According to the New Paradigm
Autorzy:
Cepiński, Wojciech
Szałański, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2202141.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pathogen
filtration
ventilation
indoor air pollution
indoor air quality
COVID-19
SARS-CoV-2
air handling unit
Opis:
The paper deals with the subject of increasing the efficiency of air purification in ventilation systems in situations of unusual hazardous indoor air pollutants. It analyzes possible locations of additional filtering and sterilizing elements in the installation to eliminate their return to the rooms. The quantities of pollutants in particular parts of the system were determined for a given fan configuration in the air handling unit and a possible leakage in the heat recovery system. Guidelines were proposed for the design and construction of systems to enable rapid modification of systems in the event of unusual contamination or pathogens in the indoor air.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 25--34
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CFD Analysis of an Innovative Wind Tower Design with Wind-Inducing Natural Ventilation Technique for Arid Climatic Conditions
Autorzy:
Obeidat, Bushra
Kamal, Hammam
Almalkawi, Amal
Powiązania:
https://bibliotekanauki.pl/articles/1839069.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wind tower
computational fluid dynamics
natural ventilation
wind pressure fluctuation
indoor air quality
passive ventilation system
Opis:
Wind towers are passive architectural elements traditionally used to ventilate buildings in the Middle East’s hot and arid regions. Some recent design initiatives in Jordan are particularly interested in using passive systems for natural ventilation. This paper focuses on an innovative wind tower design as a passive ventilation system, which will be integrated into a train station design in Aqaba, Jordan to improve the air quality in indoor spaces and reduce the cooling loads. The design uses wind-induced effects as the motivating forces to improve natural ventilation. The study optimized the wind tower and evaluated its performance using Autodesk Computational Fluid Dynamics (CFD) simulations and Grasshopper Rhino plug-ins. Airflow and distribution through the tower were analyzed using the CFD model. Grasshopper definitions were used to examine the tower efficiency in lowering the indoor air temperature. Simulations indicated the potential of the proposed wind tower to reduce the temperature by 6.164°C and supply the interior space with the required fresh air rates. This article outlines how wind towers can be used in contemporary architecture and incorporate the simulation methods to pave the way for architects to effectively validate the performance of their design proposals at the early design stage.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 86-97
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor and Outdoor Concentrations of Particulate Matter and Gaseous Pollutants on Different Floors of a University Building: A Case Study
Autorzy:
Cichowicz, Robert
Dobrzański, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1839306.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
air quality monitoring
VOCs
H2S
PM10
PM2.5
indoor air quality
outdoor air quality
Opis:
In this study, we investigate the changes in the concentrations of suspended particulate matter (PM10 and PM2.5) and selected gaseous pollutants (VOCs, H2S) in the atmospheric air inside and outside a 9-story building, which is intended primarily for the teaching activities. The purpose was to determine whether the air quality inside the building is directly dependent on the outside air quality. The analysis also included the influence of the height of the building, its location and environment, as well as meteorological conditions. No clear correlation was found between the measured parameters inside and outside the building. The height above ground (the floor on which the measurements were made) was found to have a significant influence on the concentration of each pollutant. Wind direction was also found to have a very important impact on the air quality inside the building. A strong relationship was observed on the leeward side between the concentration of impurities on the inside and outside of the building.
Źródło:
Journal of Ecological Engineering; 2021, 22, 1; 162-173
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sick building syndrome as a result of poor indoor air quality in educational and residential buildings
Syndrom chorego budynku jako rezultat złej jakości powietrza w pomieszczeniach budynków edukacyjnych i mieszkalnych
Autorzy:
Lis, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2175055.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
SBS
indoor microclimate parameters
IAQ
educational and multi-family building
CO2 concentration
parametry mikroklimatu wnętrz
budynki edukacyjne i wielorodzinne
stężenie CO2
Opis:
The main goal in the design, construction and operation of buildings should be to create a favourable environment for people. Properly selected material, construction and installation solutions allow for the creation of healthy buildings, while significantly reducing energy consumption and costs. Impact on health and methods to reduce exposure to indoor air pollution vary depending on the type of building and its intended use. The improvements should concern, first of all, proper formation of indoor air quality and the mitigation of existing exposures in the building and its surroundings. The paper discusses the phenomenon of sick building syndrome and the impact of improper ventilation and poor air quality in rooms on the formation of the syndrome symptoms. The results of research on the condition of the interior environment of pre-school, school and indoor apartments located in a multi-family residential buildings are presented. The results of measurements of selected thermal parameters of the interior microclimate, i.e. air temperature and relative humidity as well as carbon dioxide concentration, are presented. Based on the conducted questionnaires the phenomenon of the sick building syndrome was assessed among room users. Carbon dioxide levels above 1000 ppm have been exceeded, especially in educational buildings. The respondents mainly complained about the deteriorating air quality with the passage of time indoors, irritation of the eyes and respiratory tract, as well as fatigue and headache.
Głównym celem przy projektowaniu, wznoszeniu i eksploatacji budynków powinno być stworzenie środowi ska przyjaznego dla człowieka. Odpowiednio dobrane rozwiązania materiałowo-konstrukcyjne i instalacyjne pozwalają na stworzenie zdrowych budynków, jednocześnie znacznie zmniejszając zużycie energii i koszty. Wpływ na zdrowie ludzi i metody ograniczania narażenia na zanieczyszczenie powietrza w pomieszczeniach różnią się w zależności od typu budynku i jego przeznaczenia. Ulepszenia powinny dotyczyć przede wszystkim prawidłowego kształtowania jakości powietrza w pomieszczeniach oraz łagodzenia istniejących narażeń w budynku i w jego otoczeniu. Omówiono zjawisko sick building syndrome oraz wpływ niewłaściwej wentylacji i złej jakości powietrza w pomieszczeniach na powstawanie symptomów syndromu. Zaprezentowano rezultaty badań dotyczących kondycji środowiska wnętrz budynków przedszkolnych, szkolnych oraz wewnątrz mieszkań znajdujących się w budynku mieszkalnym wielorodzinnym. Przedstawiono wyniki pomiarów wybranych termicznych parametrów mikroklimatu wnętrz, tj. temperatury i wilgotności względnej powietrza oraz stężenia dwutlenku węgla. Na podstawie przeprowadzonych ankiet dokonano oceny zjawiska syndromu wśród użytkowników pomieszczeń. Zanotowano przekroczony poziom stężenia dwutlenku węgla powyżej 1000 ppm, szczególnie w budynkach edukacyjnych. Respondenci skarżyli się przede wszystkim na pogarszającą się, z upływem czasu przebywania w pomieszczeniach, jakość powietrza oraz na podrażnienie oczu i dróg oddechowych, a także zmęczenie i ból głowy.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2021, 27 (177); 141-151
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Purification in Sustainable Buildings
Oczyszczanie powietrza wewnętrznego w budynkach zrównoważonych
Autorzy:
Staszowska, Amelia
Powiązania:
https://bibliotekanauki.pl/articles/371528.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Komitet Człowiek i Środowisko PAN
Tematy:
indoor air quality
sustainable buildings
phytoremediation
photocatalysis
innovative materials
jakość powietrza wewnętrznego
zrównoważone budownictwo
fitoremediacja
fotokataliza
materiały innowacyjne
Opis:
This paper concerns the issue of indoor air purification techniques in sustainable public buildings and the residential sector. One of the requirements of sustainable construction is to reduce the energy costs, minimize waste, improve the well-being of users and create green space. The most important certification systems for green (ecological) buildings such as LEED or BREEAM also include the assessment of the indoor environment in terms of the air quality, noise level, building acoustics and energy consumption. Traditional air treatment and purification systems require the use of numerous devices, air transport systems, which are energy-consuming. It is necessary to clean or replace the working elements periodically. The alternative is biophilic installations (green walls) based on the natural properties of plants for removing gaseous pollutants, particulate matter and even bioaerosols from the air. Plants improve humidity, regulate the carbon dioxide concentration, ionize the air and suppress noise. However, the processes of photocatalytic degradation of gaseous compounds are a very promising method of removing impurities, due to low costs, mild process conditions (temperature and pressure) and the possibility of complete mineralization of impurities.
Praca dotyczy zagadnienia technik oczyszczania powietrza wewnętrznego w zrównoważonych budynkach użyteczności publicznej i sektorze mieszkalnym. Jednym z wymogów budownictwa zrównoważonego jest ograniczenie kosztów zużycia energii, minimalizacja powstawania odpadów, poprawa samopoczucia użytkowników oraz tworzenie zielonej przestrzeni. Najważniejsze systemy certyfikacji zielonych/ ekologicznych budynków takie jak LEED czy BREEAM obejmują również ocenę środowiska wewnętrznego w zakresie jakości powietrza, poziomu hałasu, akustyki budynku i jego energochłonności. Tradycyjne systemy uzdatniania i oczyszczania powietrza wymagają wykorzystania licznych urządzeń, systemów przesyłu powietrza świeżego i zużytego, które są energochłonne. Konieczne jest ich okresowe czyszczenie lub wymiana elementów roboczych. Alternatywą są instalacje biofiliczne (zielone ściany) oparte na naturalnych właściwościach roślin do usuwania z powietrza zanieczyszczeń gazowych, pyłów a nawet bioaerozoli. Rośliny poprawiają wilgotność, regulują stężenie dwutlenku węgla, jonizują powietrze i tłumią hałas. Natomiast procesy fotokatalitycznej degradacji związków gazowych są bardzo obiecującą metodą usuwania zanieczyszczeń, ze względu na niewielkie koszty, łagodne warunki prowadzenia procesów (temperatura i ciśnienie) i możliwość całkowitej mineralizacji zanieczyszczeń.
Źródło:
Problemy Ekorozwoju; 2020, 15, 2; 245-252
1895-6912
Pojawia się w:
Problemy Ekorozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural ventilation and indoor air quality in multi-family residential buildings – an indication of the problem, case study
Wentylacja naturalna a jakość powietrza wewnętrznego w budynkach mieszkalnych wielorodzinnych – wskazanie problemu, studium przypadku
Autorzy:
Stolarska, Magdalena
Lis, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2175059.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
indoor air quality
natural ventilation
hybrid ventilation
multi-family buildings
jakość powietrza wewnętrznego
wentylacja naturalna
wentylacja hybrydowa
budynki mieszkalne wielorodzinne
Opis:
Existing and designed residential buildings should provide the residents with appropriate indoor microclimatic conditions. Both in terms of thermal comfort and indoor air quality. Strong tendencies towards saving energy in buildings contribute to the use of materials with better thermal insulation (walls) and airtightness coefficients (doors and windows). In the last few years there has been a tendency towards air-tight sealing of buildings. This phenomenon can be seen both in older buildings being refurbished as well as in those that are new or thermally-upgraded. At the same time, in existing and new buildings traditional, gravity ventilation is used, and is becoming an extremely important factor in achieving the required indoor conditions. The following are some of the results of the research on this subject, which will, hopefully, provide new insight. The paper describes the use of new technologies, such as hybrid ventilation, in existing buildings. The results presented herein have been achieved from comprehensive measurements in the buildings with natural and hybrid ventilation. The aim of the paper is to present and summarize preliminary studies describing the influence of natural and hybrid ventilation as well as airtightness on an indoor environment.
Istniejące i projektowane budynki mieszkalne powinny zapewniać mieszkańcom odpowiednie warunki mikroklimatu wewnętrznego zarówno pod względem komfortu cieplnego, jak i jakości powietrza w pomieszczeniach. Silne tendencje do oszczędzania energii w budynkach przyczyniają się do stosowania materiałów o lepszej izolacyjności termicznej (ściany) i szczelności (drzwi i okna). W ciągu ostatnich kilku lat pojawiła się tendencja do hermetycznego uszczelniania budynków. Zjawisko to można zaobserwować zarówno w starych remontowanych budynkach, jak i nowych lub termomodernizowanych. Jednocześnie, w budynkach nowych oraz istniejących stosowane są tradycyjne rozwiązania wentylacji grawitacyjnej. W takich przypadkach działanie wentylacji staje się istotnym czynnikiem do realizacji wymagań jakości powietrza w pomieszczeniach. Przedstawiono wybrane wyniki badań dotyczących tej problematyki, ujmujące temat w nowym świetle, z możliwością wykorzystania nowych technologii, takich jak wentylacja hybrydowa, w istniejących budynkach. Uzyskano je drogą kompleksowych pomiarów w istniejących budynkach mieszkalnych. Celem opracowania jest zaprezentowanie i podsumowanie wstępnych badań opisujących wpływ wentylacji naturalnej i hybrydowej oraz szczelności przegród na stan środowiska wewnętrznego.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2021, 27 (177); 234-241
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microclimate in rooms heated by tiled fireplace with the function of accumulation of heat
Mikroklimat w pomieszczeniach ogrzewanych piecem kominkowym z funkcją akumulacji ciepła
Autorzy:
Telejko, M.
Zender-Świercz, E.
Powiązania:
https://bibliotekanauki.pl/articles/402011.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
building physics
ventilation
indoor air quality
heating by tiled fireplace
fizyka budowli
wentylacja
jakość powietrza wewnętrznego
ogrzewanie kominkowe
Opis:
The article presents the analysis of microclimate in rooms equipped with tiled fireplace with the function of accumulation of heat. Two research series, conducted in used premises, were presented.
Źródło:
Structure and Environment; 2016, 8, 4; 273-277
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quality inspection of nail polish removers and assessment of health hazard associated with the use of the removers
Kontrola jakości zmywaczy do paznokci oraz ocena zagrożenia zdrowia przy ich stosowaniu
Autorzy:
Huzar, E.
Wodnicka, A.
Dzięcioł, M.
Powiązania:
https://bibliotekanauki.pl/articles/126517.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
nail polish removers
volatile organic compounds
indoor air quality
zmywacze do paznokci
lotne związki organiczne
jakość powietrza wewnętrznego
Opis:
The volatile organic compounds content in nail polish removers available on the home market was determined. Qualitative and quantitative analyses of acetone, methanol, ethanol, isopropanol and ethyl acetate were performed. Theoretical VOCs concentrations in the standard room and time for reduction to low values were calculated.
Przeprowadzono badania zawartości lotnych składników zmywaczy do paznokci dostępnych na rynku krajowym. W badanych produktach zidentyfikowano i oznaczono ilościowo aceton, metanol, etanol, izopropanol i octan etylu. Określono teoretyczne stężenia lotnych związków organicznych wydzielających się ze zmywaczy do paznokci w pomieszczeniu standardowym i wyznaczono czas niezbędny do uzyskania niskich wartości tych stężeń.
Źródło:
Proceedings of ECOpole; 2010, 4, 2; 263-266
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zależność stężenia dwutlenku węgla i wilgotności względnej w sali dydaktycznej - studium przypadku
Dependence of carbon dioxide concentration and relative humidity in didactic room - case study
Autorzy:
Gładyszewska-Fiedoruk, K.
Rodero-Serrano, A.
Powiązania:
https://bibliotekanauki.pl/articles/297330.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
correlation
indoor air quality
carbon dioxide concentration
humidity
korelacja
jakość powietrza wewnętrznego
stężenie dwutlenku węgla
wilgotność względna powietrza
Opis:
Indoor air quality could influence on people health, fettle, ability to work and ability to learning. IAQ characteristics include the concentrations of pollutants (especially carbon dioxide concentration) in indoor air, as well as air temperature and humidity. General guidelines concerning the quality of air inside education rooms facilities are contained in the PN-EN 13779:2008 standard, drawn up on the basis of EU directives which are in effect in most European countries. Recommended concentration of carbon dioxide in confined spaces equals 1000 ppm. Standards show humidity from 40 to 60%. This minimum sanitary requirement is recommended by the European Office of WHO and by ASHRAE. Public buildings (education buildings) are an institution in which people the learning has a group character. As far as the quality of indoor air is concerned, education buildings have been often neglected. In countries all over the world there are public buildings which make use of different kinds of natural ventilation, and do not possess any mechanical ventilation systems. The article presents the measurement results of carbon dioxide concentration, relative humidity and interior air temperature. The measurements were taken only in one classroom, on a given day and with a varied number of people present. They are thus to be treated as a pilot study. In the classroom, natural ventilation does not provide sufficient air exchange; the air inside the classroom is dry and polluted with carbon dioxide. The correlation of humidity and carbon dioxide concentration in the classroom was examined and a strong interdependence was observed. The correlation results may be applied to how the control of ventilation. The problem of appropriate indoor air quality is significant because the correlation between the IAQ and potential energy costs reduction is more complicated that in other types of buildings. Conducting public buildings, in particular, educational buildings we must remember not only about energy savings, but also about maintaining proper indoor air quality.
W artykule zaprezentowano wyniki pomiarów stężenia dwutlenku węgla i wilgotności względnej oraz temperatury powietrza wewnętrznego. Wykonano badania tylko w jednej sali dydaktycznej, jednego dnia, przy różnej liczbie osób. Należy więc potraktować je jako badania pilotażowe. W badanej sali wentylacja naturalna zapewnia zbyt małą wymianę powietrza, powietrze wewnętrzne jest suche i zanieczyszczone dwutlenkiem węgla. Wykonano korelację wilgotności względnej powietrza i stężenia dwutlenku węgla w pomieszczeniu. Korelacja ta wykazuje bardzo silny związek. Zaprezentowane wyniki korelacji mogą posłużyć do sterowania wentylacją. Obecnie, przy bardzo szczelnych budynkach ilość zużytej energii na cele wentylacyjne, zarówno w budynkach mieszkalnych, jak i budynkach użyteczności publicznej, zbliża się do 80%. Dlatego też odpowiednie sterowanie wentylacją ma bardzo duży wpływ na efektywność energetyczną budynków.
Źródło:
Inżynieria i Ochrona Środowiska; 2017, 20, 1; 17-26
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies