Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pool" wg kryterium: Temat


Tytuł:
Estimation of solar radiation transmission for polycarbonate retractable swimming pool enclosures
Autorzy:
Zapałowicz, Zbigniew
Garnysz-Rachtan, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1845493.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
outdoor swimming pool
swimming pool roofing system
pool enclosure
polycarbonate enclosure
solar transmission through enclosure
Opis:
Application of retractable enclosures enables to lengthen operation periods for outdoor swimming pools operated in the moderate climate zone. Enclosures allow to diminish energy losses from water in the pool to the environment. Thermal calculations for pools with retractable enclosures are difficult to carry out because of a number of required parameters which can only be estimated. One of them is the transmission of solar radiation through the enclosure. The present paper presents the method of estimation of this parameter for swimming pool enclosures made of polycarbonate panels that have multichannels structure. In order to calculate transmission, the methodology considering the multiples of solar reflection inside the enclosure and their absorption by polycarbonate has been elaborated. Calculation results for transmission of the enclosure were verified experimentally. Analysis of results show that the transmission depends strongly on the enclosure’s construction and on the direction of solar radiation on the enclosure. Mean transmission values of enclosure under research were determined both from calculations and experiment are equal to about 0.69 and 0.64, respectively. However, experimentally determined mean values of total transmission by parallel and perpendicular solar directions in relation to channel axes are equal to about 0.69 and 0.60, respectively.
Źródło:
Archives of Thermodynamics; 2021, 42, 1; 129-146
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intra-population genetic diversity of cultivated carrot (Daucus carota L.) assessed by analysis of microsatellite markers
Autorzy:
Maksylewicz, Anna
Baranski, Rafal
Powiązania:
https://bibliotekanauki.pl/articles/1039480.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
SSR
biodiversity
genetic structure
gene pool
Opis:
Intra-population variation of 18 cultivated carrot (Daucus carota L. ssp. sativus) populations of diverse origins was evaluated using codominant microsatellite (SSR) markers. Using 27 genomic and EST-derived SSR markers, 253 alleles were identified with a mean 9.4 alleles per marker. Most of the alleles (60.5%) were rare i.e., with the frequency ≤ 0.05 while only 3.95% of alleles occurred with frequency > 0.6. EST-derived SSR markers were less polymorphic than genomic SSR markers. Differences in allele occurrence allowed 16 out of 18 populations to be assigned to either the Western or Asian carrot gene pools with high probability. Populations could be also discriminated due to the presence of private alleles (25.3% of all alleles). Most populations had excess of alleles in the homozygous state indicating their inbreeding, although heterozygous loci were common in F1 hybrids. Genetic diversity was due to allelic variation among plants within populations (62% of total variation) and between populations (38%). Accessions originating from continental Asia and Europe had more allelic variants and higher diversity than those from Japan and USA. Also, allelic richness and variability in landraces was higher than in F1 hybrids and open-pollinated cultivars.
Źródło:
Acta Biochimica Polonica; 2013, 60, 4; 753-760
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Comparative Analysis of the Kayak Forward Stroke
Autorzy:
Skopek, Martin
Bacakova, Radka
Bily, Milan
Tunkova, Kristyna
Powiązania:
https://bibliotekanauki.pl/articles/1922209.pdf
Data publikacji:
2019-06-05
Wydawca:
PPHU Projack Jacek Wąsik
Tematy:
counterflow pool
kayak
paddling
surface electromyography
Opis:
This work follows previous research in the field which investigated the comparison of two types of paddling. These studies, however, focused on the similarity of kayaking and trainers, more precisely ergometers, that are used by racers during their training in the winter. However, the results of these studies indicate a significant difference in muscle involvement. Aim of Study: The aim of this study is to describe and to compare the muscle activation of the kayak forward stroke performed in a pool with an opposite/counter current and on flat/calm water. Material and Methods: The research was conducted via a selected sample of eight kayakers (subjects) who had attained a high level of performance in whitewater slalom. We observed the activity of twelve selected muscles used during the kayak forward stroke performed in a counterflow pool and on flat water by means of surface electromyography and kinematic analysis. Study results point to effects in relation to intraindividual and subsequently inter-individual muscle timing and the size of the muscle activation due to maximal voluntary contraction. We used comparative analysis and the data were measured by surface electromyography and 2D video-analysis. Results: The results proved equal timing of muscles in a counterflow pool and on flat water. The muscle activity in the counterflow pool was bigger than on flat water. Conclusion: From our results we can recommend a pool which makes use of a counter current as a replacement training tool. Compared with other training devices which might be used (such as, crank ergometers, paddling trainers, and paddling pools), this kind of training device gives the kayaker one great advantage. It is the fact that the kayaker has the same placement of the fixed point and the preservation of the feeling of grasping water.
Źródło:
Physical Activity Review; 2019, 7; 107-113
2300-5076
Pojawia się w:
Physical Activity Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utonięcia małych dzieci w przydomowych basenach
Young children drowning in the private pools
Autorzy:
Michniewicz, R.
Michniewicz, I.
Powiązania:
https://bibliotekanauki.pl/articles/366157.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
śmierć
dziecko
basen
death
child
private pool
Opis:
Każdego roku, na całym świecie - również w Polsce, dochodzi do wielu wypadków, które spowodowane są wyłącznie brakiem wyobraźni czy wręcz lekkomyślnością rodziców. Specjaliści od dawna alarmują, że nawet płytki, niewielki zbiornik wypełniony wodą, na prywatnej posesji, może doprowadzić do śmiertelnego wypadku. Coraz popularniejsze i dostępne w wielu punktach sprzedaży przenośne baseny ogrodowe, są ogromnym zagrożeniem dla najmłodszych - dzieci w wieku do pięciu lat. W Polsce nie ma żadnych regulacji prawnych w zakresie konieczności stosowania zabezpieczeń wokół przydomowych basenów.
Each year in Poland, indeed all over the world, there are accidents attributable to parents' lack of imagination or recklessness. Specialists have been highlighting for a long time that even a small, shallow container filled with water and located within a private property may lead to a fatal accident. Portable garden pools, which are growing in both popularity and availability pose a significant threat to the youngest members of our communities - especially children below the age of five. In Poland there is lack of legal regulations requiring the use of protective measures around home pools.
Źródło:
Polish Hyperbaric Research; 2012, 2(39); 53-68
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of pressure on heat transfer during pool boiling of water-A1[2]0[3] and water-Cu nanofluids on stainless steel smooth tube
Autorzy:
Cieślinski, J.T.
Kaczmarczyk, T.Z.
Powiązania:
https://bibliotekanauki.pl/articles/185613.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nanofluid
ciśnienie robocze
pool boiling
operating pressure
Opis:
Experimental investigation of heat transfer during pool boiling of two nanofluids, i.e. water-Al203 and water-Cu has been carried out. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. The horizontal smooth stainless steel tubes having 10 mm OD and 0.6 mm wall thickness formed the test heater. The experiments have been performed to establish the influence of nanofluids concentration on heat transfer characteristics during boiling at different absolute operating pressure values, i.e. 200 kPa, ca. 100 kPa (atmospheric pressure) and 10 kPa. It was established that independent of nanoparticle materials (A1203 and Cu) and their concentration, an increase of operating pressure enhances heat transfer. Generally, independent of operating pressure, sub- and atmospheric pressure, and overpressure, an increase of nanoparticle concentration caused heat transfer augmentation.
Źródło:
Chemical and Process Engineering; 2011, 32, 4; 321-332
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lymphocyte labile iron pool, plasma iron, transferrin saturation and ferritin levels in colon cancer patients.
Autorzy:
Gackowski, Daniel
Kruszewski, Marcin
Banaszkiewicz, Zbigniew
Jawien, Arkadiusz
Olinski, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/1043840.pdf
Data publikacji:
2002
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
labile iron pool
iron metabolism
colon cancer
Opis:
Patients with colorectal carcinoma showed statistically significant lower values of transferrin saturation, total iron binding capacity and serum iron level as compared with control group, while the level of ferritin and the size of labile iron pool in carcinoma patients were higher, although this difference was not statistically significant. Our observations are in favour of the hypothesis which suggests that changes in iron metabolism restrict iron availability for tumour cells and as consequence, slow their growth.
Źródło:
Acta Biochimica Polonica; 2002, 49, 1; 269-273
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania żelbetowej konstrukcji basenu z lat 30. XX wieku
Examination of swimming pool concrete structure from beginnings of the 20th century
Autorzy:
Moczko, A.
Dmochowski, G.
Berkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/217776.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
konstrukcja żelbetowa
basen
concrete structure
swimming pool
Opis:
W artykule przedstawiono wyniki badań betonu i zbrojenia oraz rezultaty obliczeń konstrukcji basenu pływackiego z początku XX wieku. W celu określenia stanu technicznego obiektu zrealizowano następujące badania: określenie wytrzymałości betonu w oparciu o badania laboratoryjne próbek pobranych z konstrukcji oraz metodą "pull-out", identyfikację zbrojenia i głębokości powierzchniowej karbonatyzacji betonu. W celu określenia nośności elementów konstrukcyjnych zdefiniowano rzeczywisty model konstrukcji i przeprowadzono obliczenia wytrzymałościowe, wykorzystując dane otrzymane z analiz materiałowych. W podsumowaniu zostały określone wymagania i niezbędne prace, które należy wykonać w celu zapewnienia dalszej bezpiecznej eksploatacji basenu.
The results of concrete and reinforcement examination and structural calculations of swimming pool construction from beginnings of the 20th century are presented in the paper. In order to define technical state of the structure the following examinations were realised: determination of concrete strength basing on laboratory stress analysis and "pull-out" method, identification of reinforcement and surface concrete carbonatisation depth. To determine the bearing capacity of structural elements there was done an identification of construction static model and conducted strength calculations basing concrete data on that obtained from material examination. Finally, there were defined requirements and works necessary to be realised with aim to guarantee further safe exploitation of the swimming pool.
Źródło:
Wiadomości Konserwatorskie; 2009, 26; 108-114
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preduprezhdenie deformacijj i avarijj monolitnykh zhelezobetonnykh bassejjnov
Prevention of deformations and accidents of monolithic reinforced concrete pools
Autorzy:
Kotljar, N.
Poshhina, N.
Likhograjj, V.
Powiązania:
https://bibliotekanauki.pl/articles/78067.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
swimming pool
construction
slab
concrete mix
deformation
accident
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 6
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of pool nucleate boiling in nanofluid with lattice Boltzmann method
Autorzy:
Rostamzadeh, A.
Jafarpur, K.
Rad, E. G.
Powiązania:
https://bibliotekanauki.pl/articles/949317.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
pool boiling
nanofluid
lattice Boltzmann method
heat transfer
Opis:
Due to significant improvement of thermal performance and other properties of nanofluids, this group of liquids is in high demand. According to the literature, the effect of nanoparticles on boiling heat transfer enhancement or degradation is not the same among different investigations. In the present article, the pseudo-potential multiphase lattice Boltzmann method is used to simulate nucleate pool boiling with two different fluids: a pure liquid and a nanofluid. The current results indicate that the contact angle is the same for both the fluid and nanofluid when the vapor bubble detachment occurs. Also, bubble departure diameter is greater in the base liquid while bubble release frequency is higher in the nanofluid. In brief, the present results demonstrate that using a nanofluid instead of its base fluid will increase the boiling heat transfer coefficient.
Źródło:
Journal of Theoretical and Applied Mechanics; 2016, 54, 3; 811-825
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awaria drewnianej szkieletowej konstrukcji ścian basenu kąpielowego
Failure of skeleton timber structure of swimming pool walls
Autorzy:
Malczyk, A.
Brol, J.
Powiązania:
https://bibliotekanauki.pl/articles/161731.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen kąpielowy
budynek basenu
szkielet drewniany
awaria
przyczyna uszkodzeń
swimming pool
swimming pool building
timber frame structure
failure
destruction causes
Opis:
W artykule przedstawiono opis konstrukcji parterowego budynku basenu kąpielowego wykonanego w technologii szkieletu drewnianego. W wyniku błędów projektowych i wykonawczych, po kilku latach użytkowania obiektu wystąpił stan awaryjny konstrukcji nośnej szkieletu spowodowany butwieniem drewna. Przedstawiono sposób wymiany uszkodzonych elementów oraz jego realizację.
Structure of one floor building of swimming pool realized as a skeleton made out of timber is presented. Failure of structure was a result of decay of wood after just few years of exploitation. Paper presents a realization of damage repair.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 7-8, 7-8; 50-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sustainable restoration of the roof of a large indoor pool
Autorzy:
Pasternak, H.
Powiązania:
https://bibliotekanauki.pl/articles/403155.pdf
Data publikacji:
2011
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
basen kryty
dach
korozja
large indoor pool
roof
corrosion
Opis:
During an inspection of the roof of an indoor pool from 1971 in Potsdam (Germany) it was observed, that the roof and the column structures of the building are partially damaged by corrosion. The roof construction is a suspended simple-bent pre-stressed shell between two stiff edge beams. The span of the roof is 39.5 m. The edge beams are supported by A-frames. After further investigation on the damaged areas (including tension tests, tension tests on notched tendons with different load cycles, tests of the bearing capacity of sleeve splices and screw nuts) the conclusion was that the joint of the tension rod and the concrete column had to be restored. This was accomplished through the attaching of a new supporting construction to the existing parts, which took over the load from the old connection. At both sides of the columns pre-stressed DYWIDAG-single-tendons (St1080/1230, diameter of 36 mm) were used. They have to bear a maximal tension force of 835 kN. With this unusual restoration technique, a fast and relative inexpensive retrofitting of the construction could be carried out. The existing construction had to be modified only marginal, and the typical appearance of the building was preserved. This solution stands for sustainability.
Źródło:
Budownictwo i Inżynieria Środowiska; 2011, 2, 4; 631-637
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of chloramine concentration in swimming pool water depending on swimming pool intended use
Porównanie stężeń chloramin w wodzie basenowej w zależności od funkcji basenu
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/388965.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
swimming pool water
chloramine
disinfection
woda basenowa
chloraminy
dezynfekcja
Opis:
Swimming pool water is a mixture of supplementary water added to a closed pool circuit (usually from water supply system) and water from a pool basin, constantly purified and disinfected because of its pollution caused by bathing people. In public swimming pools, in accordance with hygiene guidelines, disinfection by chlorine compounds is required. The most commonly used is sodium hypochlorite disinfectant. The disinfectant properties of chlorine are related to its ability to oxidize organic and inorganic compounds, and the result of water chlorination is the formation of disinfection by-products (DBP). Among the most troublesome DBPs for bathers and service facility of the swimming-pool are chloramines. Chloramines are responsible for the so-called syndrome of swimmers irritation, dry skin, irritation of the mucous membranes of the nose, throat and eyes. They give the pool water and the air in the pool hall a characteristic odor and have mutagenic properties. Therefore, analyzing chloramines concentrations and taking actions, in the field of pool water treatment, in order to reduce them are very important. The primary purpose of this paper is to present the distribution of chloramines concentrations (monochloramine and dichloramine) in the pool water, depending on the pool intended use (school training pool, sports pool, pool for children to play, pool with hydromassage and water tunnel). The analysis of the results of research takes into account the swimming pool water treatment systems, exploitation parameters and the number of people bathing. The comparison of parameters (physical, chemical and bacteriological) defining the quality of the pool water, with particular emphasis on the chloramines concentrations, allows to assess the efficiency of the treatment system and the usefulness of the water to swim and bathe in relation to DIN 19643 standards.
Woda basenowa to mieszanina wody uzupełniającej zamknięty obieg basenowy (najczęściej woda z sieci wodociągowej) oraz wody z niecki basenowej, podlegającej ciągłemu procesowi oczyszczania i dezynfekcji z powodu jej zanieczyszczania przez osoby kąpiące się. W basenach publicznych, zgodnie z obowi ązującymi wytycznymi sanitarno-higienicznymi, wymagana jest dezynfekcja związkami chloru. Najczęściej stosowanym dezynfektantem jest podchloryn sodu. Właściwości dezynfekcyjne chloru związane są z jego zdolnością do utleniania związków organicznych i nieorganicznych, a wynikiem chlorowania wody jest powstawanie ubocznych produktów dezynfekcji (DBP). Spośród DBP najbardziej uciążliwymi dla osób kąpiących się i dla obsługi obiektu basenowego są chloraminy. Chloraminy odpowiedzialne są za tzw. zespół podrażnienia u pływaków, suchość skóry, podrażnienia śluzówki nosa, gardła i oczu, nadają wodzie basenowej i powietrzu w hali basenowej charakterystyczny nieprzyjemny zapach i mają właściwości mutagenne. W związku z powyższym analiza stężeń chloramin oraz podejmowanie działań z zakresu technologii wody basenowej, umożliwiających ich zmniejszenie są bardzo ważne. Podstawowym celem badań jest przedstawienie rozkładu stężeń chloramin (monochloraminy i dichloraminy) w wodzie basenowej w zależności od funkcji basenu (szkolny basen do nauki pływania, basen sportowy, basen do zabaw dla dzieci, basen z hydromasażem i tunel wodny). Analiza wyników badań uwzględnia układ oczyszczania wody basenowej, parametry eksploatacyjne oraz obciążenie niecek basenowych. Porównanie parametrów (fizyczno-chemicznych i bakteriologicznych) określających jakość wody basenowej, ze szczególnym uwzględnieniem stężeń chloramin, pozwoliło ocenić sprawność systemu jej oczyszczania i przydatność wody do kąpieli w odniesieniu do normy DIN 19643.
Źródło:
Ecological Chemistry and Engineering. A; 2015, 22, 1; 27-37
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Semi-analytical solution of optimization on moon-pool shaped WEC
Autorzy:
Zhang, W. C.
Liu, H. X.
Zhang, X. W.
Zhang, L.
Powiązania:
https://bibliotekanauki.pl/articles/963397.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
wave energy
eigenfunction expansion
moon pool
conversion ability
optimization
Opis:
In order to effectively extract and maximize the energy from ocean waves, a new kind of oscillating-body WEC (wave energy converter) with moon pool has been put forward. The main emphasis in this paper is placed on inserting the damping into the equation of heaving motion applied for a complex wave energy converter and expressions for velocity potential added mass, damping coefficients associated with exciting forces were derived by using eigenfunction expansion matching method. By using surface-wave hydrodynamics, the exact theoretical conditions were solved to allow the maximum energy to be absorbed from regular waves. To optimize the ability of the wave energy conversion, oscillating system models under different radius-ratios are calculated and comparatively analyzed. Numerical calculations indicated that the capture width reaches the maximum in the vicinity of the natural frequency and the new kind of oscillating-body WEC has a positive ability of wave energy conversion.
Źródło:
Polish Maritime Research; 2016, S 1; 25-31
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Iron-sulfur cluster proteins: electron transfer and beyond
Autorzy:
Brzóska, Kamil
Męczyńska, Sylwia
Kruszewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1041158.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
IRP1 protein
labile iron pool
aconitase
DNA glycosylases
Opis:
Iron-sulfur clusters-containing proteins participate in many cellular processes, including crucial biological events like DNA synthesis and processing of dioxygen. In most iron-sulfur proteins, the clusters function as electron-transfer groups in mediating one-electron redox processes and as such they are integral components of respiratory and photosynthetic electron transfer chains and numerous redox enzymes involved in carbon, oxygen, hydrogen, sulfur and nitrogen metabolism. Recently, novel regulatory and enzymatic functions of these proteins have emerged. Iron-sulfur cluster proteins participate in the control of gene expression, oxygen/nitrogen sensing, control of labile iron pool and DNA damage recognition and repair. Their role in cellular response to oxidative stress and as a source of free iron ions is also discussed.
Źródło:
Acta Biochimica Polonica; 2006, 53, 4; 685-691
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarządzanie miastem w chmurze – Cloud City
Management of City „in Cloud”
Autorzy:
Wrana, Krzysztof
Kmieć, Błażej
Kmieć, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/2028973.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Common pool resources
intelligent cities
open governance
public participation
Opis:
Information society is characterized by self-organization and distributed information processing abilities. At the same time there is an increase in demand for participation in local decision processes. To meet these new expectations the authors present new, alternative framework for management of cities, in which local authorities are moderators, consultants and managers, whereas all stakeholders participate in decision making within purposely created networks and groups. In the article authors also indicate selected city infrastructure elements, which ownership and management could be transferred into “city cloud”.
Źródło:
Studia komitetu przestrzennego zagospodarowania kraju PAN; 2014, 157; 91-104
0079-3507
Pojawia się w:
Studia komitetu przestrzennego zagospodarowania kraju PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie stężeń chloramin w wodzie basenowej w zależności od funkcji basenu
Comparison of chloramine concentration in swimming pool water depending on function of swimming pool
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/127065.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
woda basenowa
chloraminy
dezynfekcja
swimming pool water
chloramine
disinfection
Opis:
Przedstawiono wyniki badań stężeń chloramin w zależności od funkcji basenu. Zaprezentowano rozkład stężeń chloramin i porównano ich wielkości w wodzie basenowej. Analiza wyników badań uwzględnia układ oczyszczania wody basenowej, parametry eksploatacyjne oraz obciążenie rozpatrywanych niecek basenowych. Porównanie parametrów określających jakość wody basenowej, ze szczególnym uwzględnieniem stężeń chloramin, pozwoliło ocenić przydatność wody do kąpieli w odniesieniu do normy DIN 19643.
The distribution of chloramines concentrations in the pool water, depending on the function of the pool was presented. Analysis of the results of research takes into account the swimming pool water treatment systems, exploitation parameters and the number of people bathing. Comparison of parameters defining the quality of the pool water, with particular emphasis on the chloramines concentrations, allows to assess the usefulness of the water to swim and bath in relation to the DIN 19643 standards.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 357-363
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Modelling of Fish Passage with Turning Pools
Autorzy:
Maniecki, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/241474.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
open channel flow
fishway
turbulence
numerical model
turning pool
Opis:
An assessment of operating conditions in a baffled fish passage with pool dimensions of 2:2 3:0 m, and 180 horizontally turning pools, was carried out using numerical computations and a site survey of water flow velocity distribution. Velocity was measured with a PMS electromagnetic flowmeter and a hydrometric current meter in representative cross-sections of the fish passage in the pool centres and in the baffle barrier cross-section area. Numerical computations were also performed for two alternative baffle locations in the fishway. One reflected the actual conditions, and the other was an alternative arrangement designed to improve hydraulic conditions for fish migration. The numerical model used the Large Eddy Simulation (LES) method, which makes it possible to detect large vortexes. The study pays close attention to the velocity field analysis as well as the distribution and sizes of vortexes in the turning pool of the culvert. The results of numerical computations and the site survey show high consistency, and the proposed baffle placement modification significantly improves flow conditions, especially in the entry section of the passage.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2018, 65, 1; 41-66
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of chlorinated water on the development of allergic diseases - an overview
Autorzy:
Kanikowska, A.
Napiórkowska-Baran, K.
Graczyk, M.
Kucharski, M.A.
Powiązania:
https://bibliotekanauki.pl/articles/2081977.pdf
Data publikacji:
2018
Wydawca:
Instytut Medycyny Wsi
Tematy:
asthma
allergic rhinitis
allergic diseases
swimming pool
chlorinated water
Opis:
Indoor swimming pools can be used all year round and serve for one of the most popular sport pursued for recreation The positive effect of swimming arises in particular from the involvement of all the muscles of the body, decreasing the burden on the joints, as well as functional improvement of both the lungs and heart. Chlorine is typically used to disinfect swimming pool water and as a result the changes that take place lead to the formation of by-products, such as monochloramines (NH2Cl), dichloramines (NH2Cl2) i trichloramines (NH2Cl3), trihalogenometans (THM) or haloacetic acid (HAA). The highest concentration of these substances is just above the water surface and they may cause irritation of skin, eyes and mucosa of the respiratory tract. The toxic effect of high chlorine concentration and its side-products on the respiratory system is known, but the effect of low concentrations of these compounds is still not fully determined. Recent studies suggest that development of allergic diseases among swimmers may be increased by epithelial disorders driven by airway barrier dysfunction caused by chlorine irritation. Swimming in chlorinated water may be linked to symptoms of bronchial hyperreactivity, asthma and rhinitis especially in children, elite swimmers and employees of indoor swimming pools. Hypersensivity pneumonitis related to the use of swimming pools may manifest as a swimming pool or sauna user lung, most commonly caused by water polluting pathogens. The article summarizes recent data concerning the influence of chlorinated water on the development of allergic diseases.
Źródło:
Annals of Agricultural and Environmental Medicine; 2018, 25, 4; 651-655
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniczne aspekty transportu żywych ryb słodkowodnych
Technical aspects of the transport of live freshwater fish
Autorzy:
Chomka, G.
Kasperowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/314761.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
ryba
transport
samochód
basen
fish
transportation
car
swimming pool
Opis:
W artykule przedstawiono problemy związane z transportem żywych ryb. Omówiono również techniczne aspekty umożliwiające samochodowy transport żywych ryb słodkowodnych.
This paper presents the issues related to the transport of live fish. It also discusses the technical aspects of the car modification needed to allow the transport of live freshwater fish.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2013, 14, 10; 69-72
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Binary choice models with aversion to inequality. Individual interactions vs. mean-field interaction
Autorzy:
Ostasiewicz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/433914.pdf
Data publikacji:
2019
Wydawca:
Wydawnictwo Uniwersytetu Ekonomicznego we Wrocławiu
Tematy:
common-pool resources
binary-choice model
stationary state
multistability
Opis:
For several decades the problem of common goods has been intensively discussed and studied not only by economists, but also by politicians. One particular field of study concerns the problem of social choices realized by collective decisions, or rather individual decisions within some social collective (group). Several analytical models of using common-pool resources are proposed. Most approaches adopted within welfare economics are restricted to the maxim of this part of economics, i.e. to the maximization of the utility function. It was however discovered a long time ago that social interactions may play a significant role. In particular, aversion to inequality can be taken into account as the quantitative manifestation of the human sense of justice. Based on a simple binary choice model it is shown in this paper that by including social interactions into the decisional system of using a common-good resource, it is possible to reveal many stationary states (system multistability). Some of these stationary states may be more, and some others less beneficial from the global point of view. In this paper we investigate the eventual differences introduced by different forms of interactions between individuals. The status of the so-called mean-field approach is also examined.
Źródło:
Śląski Przegląd Statystyczny; 2019, 17 (23); 71-84
1644-6739
Pojawia się w:
Śląski Przegląd Statystyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki oraz możliwości korzystania z pływalni i parków wodnych osób z niepełnosprawnością
Access to swimming pools and water parks and their use by disabled people
Autorzy:
Czeluściński, Wiesław
Kapusta, Robert
Powiązania:
https://bibliotekanauki.pl/articles/1818337.pdf
Data publikacji:
2019-11-27
Wydawca:
Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach
Tematy:
swimming pool
disability
architectural barriers
pływalnia
niepełnosprawność
bariery architektoniczne
Opis:
Spośród wielu form rekreacji ruchowej, która ma ogromny wpływ na poprawę jakości życia, a także rehabilitację zdrowotną osób z niepełnosprawnością, ważną rolę odgrywa kontakt z wodą na pływalniach i w parkach wodnych, które coraz częściej powstają w okolicach wielu miast, osiedli i gmin. Dzięki możliwości korzystania z nich, młodzież i dorośli z różnymi problemami zdrowotnymi mają sposobność rozwijania swych umiejętności pływackich w ramach zajęć sportowych, rekreacyjnych i rehabilitacji ruchowej. Nie wszystkie jednak obiekty są przystosowane dla osób z dysfunkcjami zdrowotnymi, gdyż posiadają bariery architektoniczne, techniczne lub organizacyjne, które ograniczają lub całkowicie uniemożliwiają swobodne korzystanie z nich osobom z różnymi formami niepełnosprawności ruchowej. Dlatego ważnym zadaniem w rozwijaniu zdrowego trybu życia, kultury fizycznej i aktywnej rehabilitacji zdrowotnej jest zapewnienie warunków do korzystania z obiektów sportowych i rekreacyjnych wszystkim osobom, które tego potrzebują.
With their increasing number in and around many cities, but also in towns and villages, swimming pools and water parks are among many forms of recreation. Giving local people access to those facilities has a huge impact on improving the quality of life, as well as on the rehabilitation of people with disabilities. With an opportunity to use them, young people and adults with different health issues have a chance to develop their swimming skills in the context of sports, recreation and rehabilitation. Unfortunately, not all swimming pools or water parks are accessible to persons with disabilities because of architectural, technical or organizational barriers that limit or completely prevent people with various forms of health problems from their free use. Therefore, an important task in developing a healthy lifestyle, physical culture and active rehabilitation is to provide the right conditions for the use of sports and recreational facilities to all people that need them.
Źródło:
Student Niepełnosprawny. Szkice i rozprawy; 2018, 18, 11; 71-84
1689-6416
Pojawia się w:
Student Niepełnosprawny. Szkice i rozprawy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Pool Detergents on Formation of Chloramines in Swimming Pool Water
Wpływ środków czystości stosowanych na pływalniach na powstawanie chloramin w wodzie basenowej
Autorzy:
Stańkowska, Emilia
Włodyka-Bergier, Agnieszka
Bergier, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/385964.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
produkty uboczne dezynfekcji wody
chloraminy
środki czystości
chemia basenowa
woda basenowa
disinfection by-products
chloramines
cleaning detergents
pool chemistry
swimming pool water
Opis:
Środki czystości stosowane na pływalniach są istotnym elementem w procesie utrzymywania należytych warunków sanitarno-higienicznych. Mogą być również przyczyną zanieczyszczenia wody, a także stanowić potencjalne zagrożenie zdrowotne dla użytkowników pływalni. Badania naukowe pokazują, że połączenie substancji stosowanych podczas dezynfekcji z niektórymi zanieczyszczeniami wody basenowej może powodować powstawanie wielu groźnych produktów ubocznych. Jednym z nich są chloraminy wykazujące właściwości kancerogenne i mutagenne. Analiza czynników mających wpływ na ich powstawanie jest zatem bardzo ważna. Celem artykułu było określenie wpływu środków czystości stosowanych na pływalniach na powstawanie chloramin w wodzie basenowej. Próbki wody basenowej poddawano działaniu wybranych detergentów (Benamin AKR, Benamin SND, Randklar A, Randklar S), używanych na jednej z krakowskich pływalni, następnie badano je pod kątem zawartości monochloraminy, dichloraminy i trichloraminy. Otrzymane wyniki mogą być pomocne przy podejmowaniu działań łagodzących negatywne skutki używania środków czystości na basenach.
Cleaning agents used in swimming pools are essential elements in maintaining the proper hygiene of a swimming pool facility. They can also pollute water and cause a potential health hazard for swimming pool users. Studies show that the combination of substances used for disinfection with some contaminations presented in pool water can cause the formation of many dangerous by-products. One of these is chloramines, which have carcinogenic and mutagenic properties; this is why an analysis of the factors that influence their formation is very important. The purpose of this article is to determine the effect of pool detergents used on swimming pools on the formation of chloramines in pool water. Samples of swimming pool water were treated with selected detergents (Benamin AKR, Benamin SND, Randklar A, and Randklar S) used in one of Krakow’s public swimming pools and then tested for monochloramine, dichloramine, and trichloride. The results may be helpful in taking the steps to mitigate the negative effects of using cleaning agents.
Źródło:
Geomatics and Environmental Engineering; 2019, 13, 3; 93-102
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of heat transfer during pool boiling on minifins surface coated with carbon nanotubes
Autorzy:
Strąk, E.
Pastuszko, R.
Kłosowiak, R.
Urbaniak, R.
Powiązania:
https://bibliotekanauki.pl/articles/175588.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pool boiling
carbon nanotube
heat transfer coefficient
power
electronic cooling
Opis:
The article describes the study of heat transfer during pool boiling on minifins surface coated with nanostructure. This is a molecular level technology used in engineering or mechanical factory. A surface with carbon nanotubes (CNTs) is highly effective in reducing the superheat incipience and enhancing both the heat flux and heat transfer coefficient. The paper focuses on the comparison of the surfaces, on which pool boiling heat transfer occurs, i.e., on minifins coated with carbon nanotubes (MF+N) with surfaces formed by sintering the woven copper wire mesh to the minifins tips (MF+M) and with plain minifins surface (MF). The experiments were carried out for two boiling fluids: water and ethyl alcohol. The purpose of the presented study was to find out which of those tested surfaces and fluids could be the best alternative for use in the cooling of electronic devices and which surfaces could be used as thermosyphon or heat pipe evaporator.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 128; 59-72
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie platformy Moodle do przeprowadzania ankiet o zajęciach dydaktycznych
Use of Moodle platform for surveying students
Autorzy:
Bochniak, A.
Miaskowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/289964.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
e-learning
kształcenie na odległość
ankietyzacja
distance learning
survey pool
Opis:
Jednym z elementów oceny zajęć przeprowadzanych przez władze uczelni jest wykorzystanie procesu ankietyzacji wśród studentów. W pracy przedstawiono możliwość zastosowania platformy zdalnego nauczania Moodle do oceny zajęć przez studentów. Pokazano konstrukcję ankiety przy pomocy modułu Kwestionariusz oraz wyniki uzyskane na podstawie przykładowej ankiety przeprowadzonej po zakończeniu jednego z przedmiotów na studiach stacjonarnych dla specjalności technika komputerowa w inżynierii rolniczej.
Survey pooling is one of criteria which are used in taking measures on training activities and teachers. This article presents the usage of Moodle platform to taking students' surveys about their activities. The construction of module Questionnaire is shown on example of survey done for one obligatory subject on speciality computer technology in agricultural engineering. It is possible to evaluate activities for future relying on results of questionnaire which shows weak points of exercises and teachers. It can show what exactly students expects from lessons as well.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 11(109), 11(109); 17-23
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza opłacalności zamkniętych poolingów paletowych w przedsiębiorstwie xyz
The analysis of the profitability of use closed pallet pools in selected company
Autorzy:
Frątczak, Klaudia
Mistrzak, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/1194497.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pooling paletowy
oszczędności
optymalizacja procesów
pallets pool
savings
process optimization
Opis:
Authors of the lecture noticed huge potential of using closed pallets pools. The solution offers a lot of advantages for suppliers and recipients. In order to determine profitability, thesuggested solutions the authors made measurements in one of the warehouse company from the FMCG industry. The authors compared the times of operations using existing pallets and pallets from closed pallets pools.
Źródło:
Journal of TransLogistics; 2019, 5, 1; 131-142
2450-5870
Pojawia się w:
Journal of TransLogistics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie mikrozanieczyszczeń z makrogrupy PPCPs w wodzie basenowej
The occurence of micropollutants from PPCPs macrogroup in swimming pool water
Autorzy:
Lempart, A.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127547.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikrozanieczyszczenia
woda basenowa
GC-MS
SPE
micropollutants
swimming pool water
Opis:
Utrzymywanie mikrobiologicznej jakości wody basenowej, mające na celu zahamowania rozprzestrzeniania się zakażeń i chorób, jest priorytetem dla wszystkich właścicieli i zarządców basenów. Istnieje wiele środków dezynfekcyjnych stosowanych w basenach, które mogą potencjalnie powodować produkcję szerokiej gamy ubocznych produktów dezynfekcji (DBP). Mikrozanieczyszczenia te powstają na skutek reakcji z organicznymi i nieorganicznymi substancjami wprowadzanymi na obiekty przez ich użytkowników. Oprócz wielu ubocznych produktów dezynfekcji, w wodzie basenowej współcześnie identyfikowane są również mikrozanieczyszczenia z makrogrupy PPCPs (ang. Pharmaceuticals and Personal Care Products). Przeprowadzone w pracy chromatograficzne analizy jakościowe wody pobranej z niecki basenu szkolnego wykazały obecność ponad 100 różnych mikrozanieczyszczeń, niezidentyfikowanych dotychczas w tym środowisku, m.in. leków, hormonów, witamin, domieszek przemysłowych czy też składników kosmetyków. Do identyfikacji związków zastosowano metodę chromatografii gazowej z detekcją mas GC-MS z jonizacją elektronową poprzedzoną ekstrakcją do fazy stałej SPE (ang. Solid Phase Extraction).
Maintaining the microbial water quality in order to inhibit the spread of infections and diseases is the priority for every swimming pool owners and managers. There is a number of disinfectants that have been used for swimming pool, which potentially produce a wide range of disinfection by-products (DBPs). These micropollutants are produced by reaction with organic and inorganic matter entering swimming pools by their users. Besides DBPs there are many others micropollutants from PPCPs macro group (Pharmaceuticals and Personal Care Products) that are nowadays identified in swimming pool water. This article describes research conducted on the school swimming pool water. Qualitative chromatographic analysis have shown the presence of more than 100 micropollutants that have not been identified in these environment yet, including medicines, hormones, vitamins, industrial admixtures or cosmetic ingredients. Gas chromatography with GC-MS detection and electron ionization followed by SPE (Solid Phase Extraction) was used to identify the compounds.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 169-176
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Polish adaptation of the IPIP-BFM-50 questionnaire for measuring five personality traits in the lexical approach
Autorzy:
Strus, Włodzimierz
Cieciuch, Jan
Rowiński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2128192.pdf
Data publikacji:
2019-04-04
Wydawca:
Katolicki Uniwersytet Lubelski Jana Pawła II. Towarzystwo Naukowe KUL
Tematy:
personality
personality traits
the Big Five
International Personality Item Pool
Opis:
The article presents the Polish adaptation of Goldberg’s IPIP-BFM-50 questionnaire for measuring the five personality traits in the lexical tradition (Extraversion, Agreeableness, Conscientiousness, Emotional Stability, and Intellect). The adaptation procedure was carried out as a series of eight studies. Analyses were performed on a total of N = 7015 people aged from 10 to 83 (their mean age was 29 years). Reliability was assessed using Cronbach’s alpha coefficient. Factorial validity was verified in confirmatory factor analysis. In multigroup confirmatory factor analysis, measurement invariance between various research situations was verified. External validity was assessed by comparing the scores obtained using the IPIP-BFM-50 with NEO-FFI and NEO-PI-R scores. The results support the conclusion that the IPIP-BFM-50 is a measure with satisfactory psychometric properties, fit for use in scientific research.
Źródło:
Roczniki Psychologiczne; 2014, 17, 2; 347-366
1507-7888
Pojawia się w:
Roczniki Psychologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chlorine distribution in the indoor and outdoor swimming pools
Rozkład chloru w basenie krytym i otwartym
Autorzy:
Wyczarska-Kokot, Joanna
Lempart, Anna
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/126109.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
indoor swimming pool
outdoor swimming pool
free chlorine
combined chlorine
reliable sampling point
basen kryty
basen otwarty
zawartość chloru
miarodajne punkty poboru próbek
Opis:
The results of research on the distribution of chlorine content in the characteristic points of the outdoor pool (SPO) and indoor pool (SPI) are presented. Sports and recreational pools for swimmers were selected for the study. Technical and technological parameters of these pools are presented. Free chlorine and combined chlorine were the basic parameters affecting the quality of pool water. Their quick and easy estimation allowed to assess the spread of the disinfectant in swimming pools and the effectiveness of its operation. In both swimming pools, there was a large variation in the chlorine content and non-compliance with the requirements in this area (in SPI, content of combined chlorine > 0.3 mg Cl2/dm3, in the SPO content of free chlorine > 0.6 mg Cl2/dm3). In the SPI, in contrast to the SPO, a significant variation in chlorine concentrations was observed in samples taken from various points in the same series. Based on the analysis of the chlorine content in the characteristic points of swimming pools and physio-chemical and bacteriological supplementary parameters, an attempt was made to determine reliable sampling points to assess the quality of water. The test results were compared with the recommendations regarding the quality of swimming pool water.
Przedstawiono wyniki badań nad rozkładem zawartości chloru w charakterystycznych punktach niecek basenu otwartego (SPO) i krytego (SPI). Do badań wybrano baseny o charakterze sportowo-rekreacyjnym, dla osób umiejących pływać. Przedstawiono techniczne i technologiczne parametry tych basenów. Chlor wolny oraz chlor związany były podstawowymi parametrami wpływającymi na jakość wody basenowej. Szybki i łatwy sposób ich oznaczenia pozwolił ocenić rozprzestrzenianie się środka dezynfekcyjnego w nieckach basenowych i skuteczność jego działania. W obu basenach stwierdzono duże zróżnicowanie zawartości chloru i niezgodność z wymogami w tym zakresie (w SPI zawartość chloru związanego > 0,3 mg Cl2/dm3, w SPO zawartości chloru wolnego > 0,6 mg Cl2/dm3). W basenie SPI w odróżnieniu od SPO obserwowano znaczne zróżnicowanie stężeń chloru w próbkach pobranych z różnych punktów w tej samej serii pomiarowej. Na podstawie analizy zawartości chloru w charakterystycznych punktach niecek basenowych oraz uzupełniających parametrów fizyczno-chemicznych i bakteriologicznych podjęto próbę wyznaczenia miarodajnych punktów poboru próbek wody basenowej w celu oceny jej jakości. Wyniki badań porównano z zaleceniami, jakim powinna odpowiadać woda w pływalniach.
Źródło:
Proceedings of ECOpole; 2019, 13, 1-2; 77-84
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poszerzenie puli genetycznej jęczmienia
Broadening of barley gene pool
Autorzy:
Piechota, Urszula
Czembor, Paweł
Czembor, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2199440.pdf
Data publikacji:
2019-11-30
Wydawca:
Instytut Hodowli i Aklimatyzacji Roślin
Tematy:
jęczmień
pula genowa
mączniak prawdziwy
barley
gene pool
powdery mildew
Opis:
Przedstawiono badania nad określenie uwarunkowania genetycznego odporności na mączniaka prawdziwego czterech linii jęczmienia jarego. Badane linie wykazały odmienny profil reakcji na zastosowane izolaty, co wskazuje na obecność nowych nieznanych genów odporności. Wykazano że lokalne odmiany jęczmienia są potencjalnym źródłem efektywnej odporności.
Research to determine the genetic determinant of mildew resistance to four spring barley lines has been presented. The examined lines showed a different reaction profile for the isolates used, which indicates the presence of new unknown resistance genes. It has been shown that local varieties of barley are a potential source of effective immunity.
Źródło:
Biuletyn Instytutu Hodowli i Aklimatyzacji Roślin; 2019, 287; 41-42
0373-7837
2657-8913
Pojawia się w:
Biuletyn Instytutu Hodowli i Aklimatyzacji Roślin
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wymiana ciepła między wodą w basenach do kontrolowanego chowu ryb ciepłolubnych a otoczeniem
The heat exchange between water in pools for the controlled breeding of warmth-like fish and surroundings
Autorzy:
Żelazny, H.
Powiązania:
https://bibliotekanauki.pl/articles/290961.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
ryba
chów kontrolowany
basen
wymiana ciepła
fish
pool
heat exchange
breeding
Opis:
Celem pracy była ocena skali zjawiska wymiany ciepła drogą przewodzenia oraz ciepła suchego przenoszonego na skutek konwekcji i radiacji miedzy wodą w basenach do kontrolowanego chowu ryb ciepłolubnych a otoczeniem w istniejących obiektach fermowych. Strumienie ciepła określono metodą obliczeniową na podstawie pomiarów temperatury wody basenowej oraz parametrów powietrza wewnętrznego w czterech pomieszczeniach produkcyjnych. W trzech słabo ogrzewanych wnętrzach stwierdzono niewielkie straty ciepła z basenów na skutek przenikania przez ściany zbiorników, a w dwóch przypadkach straty konwekcyjnego ciepła suchego z powierzchni wody. W budynku o znacznie podwyższonej temperaturze powietrza strumień ciepła suchego i strumień ciepła przewodzenia przepływały w kierunku odwrotnym, to jest od otoczenia do basenów.
The aim of work was the opinion about phenomenon scale of the heat exchange by conduction and the dry heat transferred in result of convection and radiation between water in pools for the controlled breeding of fish and the surrounding in existing breeding objects. Streams of warmth was determined by the computational method on the basis of measurements of pool water temperature and parameters of internal air in four production rooms. There were affirmed that in three faintly heating rooms were small losses of the heat from pools as a result of the penetration through walls of reservoirs and in two cases there were losses of the convective dry heat from the surface of water. In the building with considerably increased air temperature the streams of dry heat and conduction run in opposite direction, from surroundings to pools.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 9 (97), 9 (97); 289-295
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elevation of the adenylate pool in rat cardiomyocytes by S-adenosyl-L-methionine.
Autorzy:
Smolenski, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/1044271.pdf
Data publikacji:
2000
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
cardiomyocytes
ribose
adenylate pool
ATP
adenine
S-adenosyl-L-methionine
adenosine
Opis:
Rapid resynthesis of the adenylate pool in cardiac myocytes is important for recovery of contractility and normal function of regulatory mechanisms in the heart. Adenosine and adenine are thought to be the most effective substrates for nucleotide synthesis, but the possibility of using other compounds has been studied very little in cardiomyocytes. In the present study, the effect of S-adenosyl-L-methionine (SAM) on the adenylate pool of isolated cardiomyocytes was investigated and compared to the effect of adenine and adenosine. Adult rat cardiomyocytes were isolated using the collagenase perfusion technique. The cells were incubated in the presence of adenine derivatives for 90 min followed by nucleotide determination by HPLC. The concentrations of adenine nucleotides expressed in nmol/mg of cell protein were initially 22.1 ± 1.4, 4.0 ± 0.3 and 0.70 ± 0.08 for ATP, ADP and AMP, respectively (n = 10, ±S.E.M.), and the total adenylate pool was 26.8 ± 1.6. In the presence of 1.25 mM SAM in the medium, the adenylate pool increased by 5.2 ± 0.4 nmol/mg of cell protein, but only if 1 mM ribose was additionally present in the medium. No changes were observed with SAM alone. A similar increase (by 4.9 ± 0.6 nmol/mg protein) was observed after incubation with 1.25 mM adenine plus 1 mM ribose, but no increase was observed if ribose was omitted. Adenosine at 0.1 or 1.25 mM concentrations also caused an increase in the adenylate pool (by 5.2 ± 1.0 and 5.2 ± 0.9 nmol/mg protein, respectively), which in contrast to the SAM or adenine was independent of the additional presence of ribose. Thus, S-adenosyl-L-methionine could be used as a precursor of the adenylate pool in cardiomyocytes, which is as efficient in increasing the adenylate pool after 90 min of incubation as adenosine or adenine. Nucleotide synthesis from SAM involves the formation of adenine as an intermediate with its subsequent incorporation by adenine phosphoribosyltransferase.
Źródło:
Acta Biochimica Polonica; 2000, 47, 4; 1171-1178
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ethanol pool fire on a one-meter test tray – validation of CFD results
Autorzy:
Cherbański, Robert
Rudniak, Leszek
Machniewski, Piotr
Molga, Eugeniusz
Tępiński, Jarosław
Klapsa, Wojciech
Lesiak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2173418.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ogień w basenie
etanol
CFD
SBES
pool fire
ethanol
large-scale
Opis:
The ethanol fire hazards will become more frequent due to the new established targets for the consumption of renewable energy sources. With this in mind, this paper aims to widen the current knowledge on CFD modelling of such a fire. As previous works rely heavily on the data of small pool fire diameters (below 1 m), this research deals with ethanol pool fire on a one-meter test tray, using our own experimental data. A mathematical model was developed and solved using a commercial CFD package (ANSYS Fluent). A new hybrid RANS-LES (SBES) model was employed to calculate turbulent stresses. Generally, the simulation results showed a good fit with the experimental results for flame temperatures at different elevations. In particular, a minor discrepancy was only observed for the top thermocouple (1.9 m above the tray). The flame heights computed with the CFD model were on average higher than the experimental one. Good agreement was observed for the radiative fraction and the axial temperature profile on the plume centreline. The latter showed an almost perfect fit between the temperature profiles obtained from CFD simulations and those calculated from the plume law for temperature.
Źródło:
Chemical and Process Engineering; 2022, 43, 1; 23--44
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cavitation-Reagent Technology for Water Purification of Pools and Water Parks
Autorzy:
Aftanaziv, Ivan
Shevchuk, Lilija
Malovanyy, Myroslav
Strutynska, Lesya
Samsin, Igor
Powiązania:
https://bibliotekanauki.pl/articles/125410.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pool
water purification
electrolysis
cavitation
vibration
elastic system
oscillation
working chamber
Opis:
The research goal was to develop an improved water purification technology for public reservoirs by adding the vibrocavitation purification before a reagent method with sodium hypochlorite, produced via electrolysis of salt. The main tasks of the research include the determination of vibrocavitation treatment efficiency and the development of a new low-frequency vibration resonance cavitation process for water purification, as well as equipment for this process. The vibroresonance method supporting the intensity of spatial displacements of cavitation exciters was developed on the basis of the theory of cavitation fields in liquids. While using this method, it was possible to establish the boundary conditions for stable support of the cavitation field created by low-frequency vibrations. The developed method is based on the formation of high intensive cavitation fields in liquids by vibratory decks. The advanced technological scheme of water purification for pools and public use reservoirs was proposed, which includes the addition of resonance vibrocavitators to a closed circulation cycle of water purification with the reagent method.
Źródło:
Journal of Ecological Engineering; 2019, 20, 6; 141-152
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The hidden potential of advantages offered by a wooden pallet in a heterogeneous pallet pool – theoretical and analytical view
Autorzy:
Jedliński, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/24202548.pdf
Data publikacji:
2022
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
logistics infrastructure
wood pallets pool
hidden value
supply chain
logistics process
Opis:
A flat wooden pallet, being a simple logistics carrier in terms of its structure, can nonetheless be treated as a highly specialized logistical and marketing object applied in complex supply chains. Rigorous measures taken to standardize pallets are predominantly aimed at ensuring the highest possible safety level for the transported products and people handling the freight units during the complex logistical processes that involve pallets along supply chains. The goal of this article was to increase understanding of the operating strategies employed by entities using pallet pools, as well as the organizational, operational, and market challenges faced by them. It was hoped to achieve this goal via both theoretical and empirical studies. To this end, the research study applied theoretical synthesis and empirical evidence derived from primary research based on the industrial, transport, forwarding, and logistics markets. At the same time, the theoretical context was based on the literature on the subject, related to wooden pallet issues and their special role in logistical processes. Challenges connected with decisions made to enable effective and efficient management of pallet pools were addressed at legal and regulatory, as well as organizational and operational, levels. Diverse courses of action identified in several stakeholder groups were reflected in the adopted philosophy of managing the main feeding streams of pallet pools. Though limited to just the Polish market, the research study was sufficiently representative due to the strategic share of the European and global market of standard flat wooden pallets. The author proposes taking a perspective of value-added synergy as an alternative (to be understood as different and complementary rather than excluding possibilities) to other ways of approaching the value of supply chains. The undertaken considerations may contribute to increasing the awareness of the importance of taking a pallet, so common from the technical and technological point of view, as a value-added carrier in scientific considerations, due to its paradoxically low individual economic vulnerability.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2022, 71 (143); 111--119
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of 1-methylnicotinamide and its metabolite N-methyl-2-pyridone-5-carboxamide on streptozotocin-induced toxicity in murine insulinoma MIN6 cell line
Autorzy:
Przygodzki, Tomasz
Slominska, Ewa
Polakowska, Ewa
Mlynarski, Wojciech
Watala, Cezary
Powiązania:
https://bibliotekanauki.pl/articles/1039953.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
nucleotide pool
streptozotocine
1-methylnicotinamide
N-methyl-2-pyridone-5-carboxamide
Opis:
1-methylnicotinamide (MNA) is a primary metabolite of nicotinamide. In recent years several activities of MNA have been described, such as anti-inflammatory activity in skin diseases, induction of prostacyclin synthesis via COX-2, aortal endothelium protection in diabetes and hypertriglyceridaemia and increased survival rate of diabetic rats. 1-methylnicotinamide was also suggested to protect pancreatic cells from streptozotocin in vivo. Streptozotocin toxicity is known to be mediated by poly-ADP-ribose polymerase. Nicotinamide and its derivatives have been shown to ameliorate poly-ADP-ribose polymerase-dependent nucleotide pool reduction. We aimed to verify if 1-methylnicotinamide and its metabolite, N-methyl-2-pyridone-5-carboxamide, can protect insulinoma cells from streptozotocin-induced toxicity. We found that N-methyl-2-pyridone-5-carboxamide, but not 1-methylnicotinamide, restores the pool of ATP and NAD+ in streptozotocin-treated cells, but neither compound improved the cell viability. We conclude that inhibition of poly-ADP-ribose polymerase-dependent nucleotide pool reduction may not be sufficient to protect cells from streptozotocin toxicity.
Źródło:
Acta Biochimica Polonica; 2011, 58, 1; 75-77
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the filtration bed type in the pool water treatment system on washings quality
Wpływ rodzaju złoża filtracyjnego w układach oczyszczania wody basenowej na jakość popłuczyn
Autorzy:
Wyczarska-Kokot, J.
Lempart, A.
Powiązania:
https://bibliotekanauki.pl/articles/126751.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
filter beds
washings
swimming pool
sedimentation
złoża filtracyjne
popłuczyny
basen
sedymentacja
Opis:
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and possibility of reusing the washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of drainage of washings into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of the washings from the analyzed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. The washings were sedimented and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
Przedstawiono wpływ rodzaju złóż filtracyjnych, stanowiących wypełnienie filtrów w układach oczyszczania wody basenowej, na jakość i możliwość zagospodarowania popłuczyn. Badaniami objęto 4 obiegi basenowe, w których zastosowano złoża: piaskowe, piaskowo-antracytowe, szklane oraz okrzemkowe. Stopień zanieczyszczenia popłuczyn oceniono na podstawie badań fizyczno-chemicznych i bakteriologicznych próbek popłuczyn. Rozważono możliwość odprowadzania popłuczyn do środowiska naturalnego, a wyniki badań porównano z dopuszczalnymi wartościami wskaźników zanieczyszczeń dla ścieków odprowadzanych do wód lub ziemi. Bezpośrednie zagospodarowanie popłuczyn z analizowanych filtrów okazało się niemożliwe przede wszystkim ze względu na duże zawartości zawiesin ogólnych oraz chloru wolnego. Z tego względu popłuczyny poddano sedymentacji, a wodę nadosadową intensywnemu mieszaniu. W wyniku tych procesów jakość popłuczyn uległa znacznej poprawie. Pozwoliło to planować uzupełnianie instalacji wody basenowej o układy zagospodarowania popłuczyn.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 355-361
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gene pool variation of Fragaria × ananassa (Duch.) and Fragaria vesca (L.)
Zmienność w obrębie zasobów genowych Fragaria × ananassa (Duch.) i Fragaria vesca (L.)
Autorzy:
Dziadczyk, E.
Dziadczyk, P.
Tyrka, M.
Powiązania:
https://bibliotekanauki.pl/articles/11543047.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
gene variant
Fragaria ananassa
Fragaria vesca
gene pool
hybrid
interspecific hybrid
Opis:
Gene pool variation of twenty varieties and breeding clones of Fragaria × ananassa, nine varieties and breeding lines of Fragaria vesca, and one new interspecific hybrid designated Fragaria × anavesca was analysed with three DNA marker systems. ISSR reactions with four primers produced 45 polymorphic markers. Similarly, RAPD analyses with three primers produced 26 markers and SSR method with three primer pairs revealed 28 different alleles. The total number of 99 polymorphic markers allowed distinguishing clearly a group of F. × ananassa genotypes from that of F. vesca genotypes with F. × anavesca in between of these two. RAPD markers proved to be more informative than ISSRs as 3 of 26 were specific to F. × ananassa only and one exclusively to F. vesca and F. × anavesca. Thus, the presumed hybrid nature of F. × anavesca was effectively confirmed by RAPD markers. Especially important was the 1100bp long PCR product of the B104 primer present in all F. vesca genotypes as well as in F. × anavesca but absent in F. × ananassa. Presence of F. vesca DNA in the hybrid F. × anavesca was additionally corroborated by the 223bp product of the UDF017 primer pair and the 185bp-long band generated with the UDF006 primer pair.
Analizowano zmienność w puli genów dwudziestu odmian i klonów hodowlanych Fragaria × ananassa, dziewięciu odmian i linii hodowlanych Fragaria vesca i nowego prawdopodobnego mieszańca międzygatunkowego nazwanego Fragaria × anavesca przy zastosowaniu trzech systemów markerów DNA. Cztery startery ISSR wygenerowały 45 markerów polimorficznych. Trzy startery RAPD dały 26 markerów, natomiast trzy startery SSR – 28 markerów polimorficznych. 99 uzyskanych markerów polimorficznych pozwoliło na jednoznaczne odróżnienie grupy genotypów należących do gatunku F. × ananassa od grupy genotypów należących do gatunku F. vesca z mieszańcem F. × anavesca sytuującym się pomiędzy nimi. Markery RAPD okazały się lepszym źródłem informacji niż ISSR, ponieważ 3 spośród 26 były specyficzne tylko dla F. × ananassa, a jeden wyłącznie dla F. vesca i F. × anavesca. W ten sposób, za pomocą markerów RAPD, potwierdzona została przypuszczalna wcześniej mieszańcowość F. × anavesca. Szczególnie istotny okazał się produkt reakcji PCR ze starterem B104 o długości 1100pz obecny we wszystkich genotypach F. vesca oraz F. × anavesca, a niewystępujący u F. × ananassa. Obecność DNA pochodzącego z F. vesca w mieszańcu F. × anavesca została dodatkowo potwierdzona poprzez produkt pary starterów UDF017 o długości 223pz i produkt pary starterów UDF006 o długości 185pz.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2015, 14, 2; 41-50
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health risk as a consequence of exposure to trihalomethanes in swimming pool water
Autorzy:
Bozym, M.
Wzorek, M.
Klosok-Bazan, I.
Powiązania:
https://bibliotekanauki.pl/articles/872856.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
health risk
toxicological exposure
human exposure
trihalomethane
toxicity
swimming pool
swimming water
Opis:
The article presents the formation and toxicity of trihalomethanes (THMs), substances belonging to Disinfection By- Products (DBP), formed as a result of pool water chlorination. Concentration of THMs in pool water has been standardised in Poland since recently. THMs concentration in pool water depends on multiple factors, mostly the method of water disinfection, including chlorine or organic substance (TOC) concentration. Apart from that, the level of exposure of swimmers to the toxic effect of THMs is affected by their content in the air of swimming pool halls, intensity of swimming as well as time of stay in the indoor swimming pool area. The water and air temperature as well as number of swimmers and time of their staying in pool have also significance influence on THMs concentration. In order to decrease the quantity of THMs in pool water, alternative disinfection agents are applied. Additionally, an efficiently operating pool ventilation system as well as proper water treatment method are also important. Because THMs are produced from organic material under the influence of the chlorination, the users can have an impact on decrease of the THMs concentration in pool water, for instance by taking a shower prior to entering the pool or by wearing a swim cap. The results of studies conducted in 2015 showed that the quantity of THMs in pool water depends on type of the pool (indoor, outdoor), water replacement frequency, water treatment system, chlorine dose and TOC content. In most collected samples, the THMs concentration exceeded the admissible norm (100 μg/L).
W artykule omówiono powstawanie i działanie toksyczne trihalometanów (THM), związków należących do tzw. Disinfection By-Products (DBP), powstających w wyniku chlorowania wody w nieckach basenowych. Od niedawna w Polsce normuje się stężenie tych związków w wodzie basenowej. Stężenie THM w wodach w obiektach basenowych zależy od wielu czynników, głównie od sposobu dezynfekcji wody, w tym stężenia chloru oraz substancji organicznych (TOC). Poza tym na stopień narażenia pływaków na toksyczne działanie THM ma ich zawartość w powietrzu hali basenowych, intensywność pływania oraz czas przebywania na terenie pływalni. Ważna jest też temperatura wody i powietrza oraz ilość osób korzystających z basenu w danym czasie. W celu zmniejszenia ilości THM w wodzie basenowej stosuje się alternatywne środki dezynfekcji. Poza tym ważny jest sprawnie działający system wentylacji hali basenowej i odpowiedni sposób oczyszczania wody. Ponieważ THM są wytwarzane z udziałem substancji organicznych pod wpływem chlorowania, korzystający z basenów mogą wpłynąć na obniżenie poziomu THM, np. poprzez noszenie czepków oraz skorzystanie z prysznica przed wejściem do wody. Przeprowadzone w 2015 roku badania wykazały, że ilość THM w wodzie basenowej zależy od wielu czynników, w tym rodzaju basenu (kryty, odkryty), częstości wymian wody, rodzaju systemu jej oczyszczania, dawki chloru oraz zawartości TOC. W większości pobranych próbek stężenie THM przekraczało dopuszczalną normę (100 μg/L).
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobro wspólne okiem socjologa — kilka uwag porządkujących
The Common Good in the Eye of the Sociologist—A Few Ordering Remarks
Autorzy:
Mika, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/1373002.pdf
Data publikacji:
2017-10-10
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multitude
socialization
ownership
common-pool resources
wielość
uspołecznienie
własność
dobra wspólnej puli
Opis:
This text can be defined as an attempt to look at the question of the common good through sociological glasses. The author suggests that many of the issues subsumed under  the term “the common good” have already been elucidated and described in detail on the basis of classical and contemporary sociology. If it is assumed that the common good can be understood triply, as (1) a postulate of the social good, (2) materially, as an object of collective ownership, and (3) as an effect of the individual’s life in society, then it must be admitted that, at least in the third case, reference to the collected achievements of sociology is necessary in order to describe the common good properly.
Źródło:
Kultura i Społeczeństwo; 2017, 61, 4; 49-63
2300-195X
Pojawia się w:
Kultura i Społeczeństwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health Risk Assessment of Swimming Pool Users from the Effects of Legionella Spp. Contamination of Water
Autorzy:
Zimoch, Izabela
Paciej, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/124346.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
Legionella spp.
swimming pool
health risk assessment
GIS technology
water quality control
Opis:
One of the main problems in the scope of public health is poor identification of the waterborne diseases and their etiology. One of the aims of the new directive concerning the quality of water intended for human consumption is to implement the principles of hazard assessment in water supply systems (WSS) in the member states, on the basis of water quality monitoring and analyses of the system functioning conditions. The implementation of risk management procedures in WSSs is to ensure an increase in the water supply safety and, in turn, protect the consumer’s health against the harmful effects of any potable water contamination. At present, the secondary legislation to the Polish acts implementing the Directive of the Council of Europe is the Regulation of the Minister of Health on the quality of water intended for human consumption, which also sets forth the scope of monitoring the quality of hot water for Legionella spp., which can be an etiological factor of legionellosis. Another act regulating the water quality in terms of Legionella spp. is the Regulation of the Minister of Health on water quality in swimming pools. These acts, referring to the parameter of Legionella spp., are complementary. This paper presents the results of evaluating the change in the sanitary status of hot water quality in terms of contamination with Legionella spp. bacteria in the selected swimming pool facilities in southern Poland (Silesian Voivodship). On the basis of the available water quality test from state inspections (Chief Sanitary Inspectorate), an analysis of the microbiological quality of hot water in swimming pools was conducted. The analyses included a spatial distribution of those facilities, which results from the regionalisation subject to the territorially competent public health authority exercising supervision over the water quality in the Silesian Voivodship. The methods were presented for determination of the health risk of swimming pool users as a result of contamination of swimming pool water with Legionella spp. in relation to the availability of a given recreation facility. The final result of these studies is the use of GIS (Geographic Information System) tools in spatial risk interpretation.
Źródło:
Journal of Ecological Engineering; 2020, 21, 2; 178-189
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evolutionary algorithm with a configurable search mechanism
Autorzy:
Łapa, Krystian
Cpałka, Krzysztof
Laskowski, Łukasz
Cader, Andrzej
Zeng, Zhigang
Powiązania:
https://bibliotekanauki.pl/articles/1837536.pdf
Data publikacji:
2020
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Tematy:
evolutionary algorithm
population-based algorithm
optimization
operator pool
operator selection
individual selection
Opis:
In this paper, we propose a new population-based evolutionary algorithm that automatically configures the used search mechanism during its operation, which consists in choosing for each individual of the population a single evolutionary operator from the pool. The pool of operators comes from various evolutionary algorithms. With this idea, a flexible balance between exploration and exploitation of the problem domain can be achieved. The approach proposed in this paper might offer an inspirational alternative in creating evolutionary algorithms and their modifications. Moreover, different strategies for mutating those parts of individuals that encode the used search operators are also taken into account. The effectiveness of the proposed algorithm has been tested using typical benchmarks used to test evolutionary algorithms.
Źródło:
Journal of Artificial Intelligence and Soft Computing Research; 2020, 10, 3; 151-171
2083-2567
2449-6499
Pojawia się w:
Journal of Artificial Intelligence and Soft Computing Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ARIMA model used to analyze the demand for swimming pool services
Autorzy:
Pawlisiak, Mieczysław
Powiązania:
https://bibliotekanauki.pl/articles/970657.pdf
Data publikacji:
2019-03-31
Wydawca:
Uniwersytet Gdański. Wydział Ekonomiczny
Tematy:
arima model
lifeguarding and water rescue
readiness
swimming pool
swimming baths
safety
Opis:
Na preferencje klientów wybierających aktywną formę spędzania wolnego czasu wpływa wiele czynników. Bogata oferta rynkowa daje szerokie możliwości, a od obiektów sportowych wymaga się, aby pozostawały w pełnej gotowości do świadczenia usług. Pomocne w takim przygotowaniu jest konstruowanie prognoz umożliwiających określenie przewidywalnej liczby klientów. Przykład takiej predykcji, sporządzonej na podstawie pływalni, przedstawiono w niniejszym artykule. W tym celu wykorzystano model ARIMA bazujący na założeniu, że na wartość zmiennej objaśnianej wpływa wartość tej zmiennej opóźniona w czasie.   Klasyfikacja JEL: C2, C22. 
Many factors influence customer preferences among those who choose active leisure. A wide range of market productsmakes for many opportunities, and sports facilities are required to be fully prepared to provide services. It is helpful to create forecasts that enable to determine the predictable number of clients. An example prediction made with respect to swimming pools is presented in this article. For this purpose, the ARIMA model was used, based on the assumption that the value of the endogenous variable is affected by the value of this variable laggedin time. JEL classification: C2, C22. 
Źródło:
Współczesna Gospodarka; 2019, 10, 1 (32); 55-68
2082-677X
Pojawia się w:
Współczesna Gospodarka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhancement of the pool boiling heat transfer coefficient using the gas injection into the water
Autorzy:
Sarafraz, M.M.
Peyghambarzadeh, S.M.
Alavi Fazel, S.A.
Powiązania:
https://bibliotekanauki.pl/articles/778947.pdf
Data publikacji:
2012
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
heat transfer
pool boiling
Gas-liquid solution
Nucleation site density
SO2
water
Opis:
In this paper, a new method for enhancing the pool boiling heat transfer coefficient of pure liquid, based on the gas injection through the liquids has been introduced. Hence, the effect of gas dissolved in a stagnant liquid on pool boiling heat transfer coefficient, nucleation site density, and bubble departure diameter has experimentally been investigated for different mole fractions of SO2 and various heat fluxes up to 114 kW/ m2. The presence of SO2 in captured vapor inside the bubbles, particularly around the heat transfer surface increases the pool boiling heat transfer coefficient. The available predicted correlations are unable to obtain the reasonable values for pool boiling heat transfer coefficient in this particular case. Therefore, to predict the pool boiling heat transfer coefficient accurately, a new modified correlation based on Stephan-Körner relation has been proposed. Also, during the experiments, it is found that nucleation site density is a strictly exponential function of heat flux. Accordingly, a new correlation has been obtained to predict the nucleation site density. The major application of the nucleation site density is in the estimating of mean bubble diameters as well as local agitation due to the rate of bubble frequency.
Źródło:
Polish Journal of Chemical Technology; 2012, 14, 4; 100-109
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effects of The Common Fisheries Policy on the theory of the availability of marine resources
Autorzy:
Gielo-Politewicz, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/970662.pdf
Data publikacji:
2019-03-31
Wydawca:
Uniwersytet Gdański. Wydział Ekonomiczny
Tematy:
common pool resources
exploitation of marine resources
tragedy of
common
common fisheries policy
Opis:
The aim of the paper is to present issues connected with responsibility in the fishery industry. The paper discusses the ‘tragedy of common.’ An attempt was made to formulate proposals for how to increase the efficiency of marine resource management and reduce the problem of declining fisheries. The publication analyses the current Common Fisheries Policy in the context of overfishing. It will take a great deal of serious effort for fishermen, scientists and politicians to solve the problem of the Baltic Sea. The rebirth of fish stocks will create healthier ecosystems and greater reproduction of fish populations. A higher number of fish schools may result in more balanced catch figures. It is expected that profits will increase and thereby result in more jobs and higher salaries, leading to a greater overall profitability of the fishing sector. Keywords: common pool resources, exploitation of marine resources, tragedy of common, Common Fisheries Policy JEL classification: Q 22
Źródło:
Współczesna Gospodarka; 2019, 10, 1 (32); 21-33
2082-677X
Pojawia się w:
Współczesna Gospodarka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fenomenologiczna ocena tworzenia się struktur wodno-olejowych podczas wrzenia w objętości
Phenomenological assessment of water-oil patterns formed during pool boiling
Autorzy:
Troniewski, L.
Filipczak, G.
Witczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/2070619.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wrzenie w objętości
struktury wrzenia
wnikanie ciepła
pool boiling
boiling patterns
heat transfer
Opis:
W pracy przedstawiono wyniki badań i analiz dotyczących warunków wnikania ciepła podczas wrzenia mieszaniny cieczy wzajemnie nierozpuszczalnych. Eksperymenty przeprowadzono w dużej objętości i pod ciśnieniem atmosferycznym, wykorzystując jako czynniki robocze wodę oraz oleje o różnych właściwościach. Scharakteryzowano warunki wnikania ciepła przy różnej zawartości obu składników mieszaniny.
Experimental results of heat transfer during pool boiling of two immiscible liquids are presented. The experiments were carried out under atmospheric pressure. Water and various oil mixtures were used as working liquids. The conditions of heat transfer for a different content of both liquids in the mixture were characterized.
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 6; 188-189
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania weryfikujące opinię o możliwości ogrzewania wody w basenach dla ryb poprzez ogrzewanie powietrza w budynku
Research verifying the opinion concerning possibility to heat water in pools for fish by means of heating air in a building
Autorzy:
Żelazny, H.
Powiązania:
https://bibliotekanauki.pl/articles/290840.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
bilans ciepła
basen
samoogrzewanie wody
ryba
ferma
heat balance
pool
fish
farm facility
Opis:
Celem pracy było zweryfikowanie na podstawie badań instrumentalnych opinii o możliwości ogrzewania wody w basenach do przemysłowej produkcji ryb poprzez ogrzewanie powietrza wewnętrznego w zamkniętym obiekcie fermowym. Zakresem analizy objęto zyski i straty ciepła między wodą w zbiornikach na ryby a otoczeniem na drodze promieniowania, konwekcji suchej i mokrej oraz przewodzenia przez ściany basenów. Pomiary parametrów termicznych powietrza i wody w basenach przeprowadzono w czterech eksploatowanych pomieszczeniach kontrolowanego chowu suma afrykańskiego. We wszystkich przypadkach straty z wody przewyższały zyski strumienia ciepła z powietrza, nie wyłączając fermy w Bańskiej, w której temperatura powietrza była podniesiona w stosunku do temperatury wody aż o 4°C. Stąd należałoby poddać w wątpliwość samoogrzewanie się wody od powietrza w tego typu obiektach.
The purpose of the work was to carry out an instrumental research aimed to verify the opinion regarding possibility to heat water in pools for industrial scale fish production by means of heating inside air in a closed farm facility. The scope of the analysis covered heat gains and losses between water in reservoirs for fish and environment resulting from radiation, dry and wet convection, and conduction through pool walls. Thermal parameters of air and water in the pools were measured in four rooms currently used for controlled African sheatfish breeding. In all cases losses from water were higher than gains of heat flux gains from air, including the farm in Banska, in which air temperature was as much as 4°C higher compared to water temperature. Thus, the process of spontaneous water heating resulting from its contact with air in facilities of this type should be questioned.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 5(103), 5(103); 411-418
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of the irradiation facility SIBO INRA/Tangier, Morocco by upgrading cobalt-60 in a temporary pool and enhancing safety and control features
Autorzy:
Mohammed, M.
Mouad, C.
Amina, G.
Powiązania:
https://bibliotekanauki.pl/articles/147184.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gamma irradiator
temporary pool
nuclear safety
dry store irradiator
cobalt-60
security systems
Opis:
An automatic control system is one of the most important parts of an irradiation facility. The level of this control is always maintained to comply with safety procedures during routine work in this field. Also sometimes it is limited to the minimum level of regulation required due to economical aspects; some commercial systems are generally made by manufacturers of industrial facilities and considered affordable by irradiators. In some cases specific irradiation facilities tailor their control systems to their needs. For this kind of irradiator the control system can be developed and upgraded according to personal and industrial experiences. These upgrading procedures are also used by others to develop their systems. The objective of this paper is to share a local experience in upgrading security, safety systems and the use of cobalt-60 for the irradiator. It is a composite experiment at SIBO INRA/Tangier, Morocco and concerns the: (i) upgrade of cobalt-60 in a temporary pool in the SIBO irradiator in Tangier. This operation was conducted in collaboration with the International Atomic Energy Agency (IAEA) and was a success story of 2014 according to the general conference of IAEA; (ii) safety and technical upgrade of the system in the SIBO irradiator made in collaboration with IAEA; (iii) installation and upgrade of the security system in accordance with the Global Threat Reduction Programme (GTRP) to reduce the threat of a Radiological Dispersal Device (RDD) in collaboration with The United States Department of Energy’s National Nuclear Security Administration (NNSA).
Źródło:
Nukleonika; 2017, 62, 4; 303-309
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations on water circulation in animal sea-water basins – on the example of seals’ breeding pools
Autorzy:
Zima, P.
Powiązania:
https://bibliotekanauki.pl/articles/259209.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
circulation of water in animal breeding pool
water flow through the pools
computer simulation
Opis:
This paper presents general comments concerning investigations on water circulation in animal breeding pools containing sea water. As an example are given results of computer simulation of water circulation in seals’ breeding pools situated in Marine Station at Hel, belonging to Oceanographic Institute , Gdansk University. A mathematical model of three main pools was prepared with taking into account their inflow and outflow water supply points. Next, the object indication ( tracer) tests were done with the use of mathematical modelling as well as in-situ measurements. For description of flow field in steady conditions a simplified model of 2D flow in the form of Helmholtz biharmonic equation of stream function , recalculated then into velocity vector components, was used. The equation , supplemented with appropriate boundary conditions , was solved numerically by using the finite differences method. The spreading of a substance dissolved in water (tracer) was analyzed by solving 2D equation of transient advecting - dispersing transport. To solve it the finite volumes method was applied. The applied model was verified by conducting the indication tests with the use of the rhodamine WT as a tracer. The obtained results made it possible to reconstruct water circulation within the seals’ pools and identify stagnation zones in which water circulation may be made difficult.
Źródło:
Polish Maritime Research; 2017, S 1; 224-229
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczna symulacja pożaru powierzchniowego powstałego w wyniku wycieku LNG
Numerical simulation of LNG pool fire
Autorzy:
Rudniak, L.
Molga, E.
Powiązania:
https://bibliotekanauki.pl/articles/2073252.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
modelowanie CFD
pożar powierzchniowy
LNG
promieniowanie cieplne
CFD simulation
LNG pool fire
heat irradiance
Opis:
W pracy wykorzystano oprogramowanie ANSYS Fluent 18.1 do numerycznego modelowania pożaru powierzchniowego. Model CFD wymagał numerycznego rozwiązania równań bilansu masy, pędu, zmodyfikowanego modelu turbulencji SAS, energii oraz bilansu składników. Wyniki uzyskane z numerycznej symulacji wycieku skroplonego gazu LNG w postaci profili temperatury, intensywności emitowanego przez spalany gaz promieniowania cieplnego oraz stężenia produktów spalania posłużyły do oceny skutków takiego pożaru.
In the presented paper, commercial CFD code ANSYS FLUENT 18.1 has been used to curry out the numerical simulation of LNG pool fire. The applied CFD model required to solve numerically: continuity and momentum equations together with enhanced two-equation turbulence model (SAS), and also energy and components balance equations. The results obtained in numerical simulation such as temperature, incident heat radiation and reagent concentration profiles were used in assessment of a risk of LNG pool fire.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 3; 102--103
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zasoby przyrodnicze jako przykład dóbr typu CPR (common-pool resources). Konflikty o dostęp do wspólnych zasobów i ich znaczenie dla rozwoju lokalnego i regionalnego
Natural Resources as an Example of Common-pool Resources. Conflicts Over Access to Common Goods and Their Importance for the Local and Regional Development
Autorzy:
Wołyniec, Łukasz Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2096810.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Instytut Socjologii
Tematy:
natural resources
common-pool resources
conflicts
easements
zasoby przyrodnicze
zasoby wspólnej puli
konflikty
służebności
Opis:
Artykuł traktuje zasoby przyrodnicze jako przykład dóbr typu CPR (common-pool resources). Omawiane są one w kontekście konfliktów o dostęp do zasobów na obszarach o szczególnych walorach przyrodniczych. Jeden z konfliktów sprowadza się potwierdzenia ważności służebności nadanych polskim chłopom przez rosyjskiego cara w XIX wieku. Ich potomkowie domagają się prawa do bezpłatnego połowu ryb w jeziorach. Drugi przykład konfliktu odnosi się do Puszczy Białowieskiej i rządowych propozycji powiększenia Białowieskiego Parku Narodowego. Zaobserwowane konflikty przypominają szeroko omawiane w literaturze dylematy CPR. Ich rozwiązanie będzie miało istotne znaczenie z punktu widzenia zapewnienia tym obszarom możliwości rozwoju.
The article treats natural resources as an example of common-pool resources, which arediscussed in the context of conflicts over access to the resources located in areas of natural value. One of these conflicts comes down to confirmation of the validity of easements given toPolish peasants by the Russian Tsar in the 19th century. Their descendants demand the free access to fisheries in lakes. Another example of such conflict is related to the Białowiez ̇a Forrest and government proposals to enlarge the area of Białowiez ̇a National Park. Observed conflicts resemble CPR dilemmas widely discussed in the literature. The solution will be important toprovide opportunities for development in these areas.
Źródło:
Konteksty Społeczne; 2013, 1, 2; 57-64
2300-6277
Pojawia się w:
Konteksty Społeczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The evaluation of the public perception of the implementation of “Rajgród FW6 Polska wind farm”
Autorzy:
Rauba, K.
Zimińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/96114.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
farma wiatrowa
społeczne postrzeganie inwestycji
ankieta
wind farm
social perception of investments
opinion pool
Opis:
Renewable energy sources play a key role. The Polish legal system takes into account public participation in the investment process. This also applies to the construction of a wind power plant. In Poland, there is still opposition from local communities to the choice of location and the implementation of an investment project involving the construction of a wind power plant. The aim of this article is to assess the public perception of the construction of a wind farm located in the municipality of Rajgród. The survey of the local community opinion was conducted on the basis of a questionnaire carried out through a direct interview. By using the conditional valuation method (CVM), which uses the ready-to-pay (WTP) techniques, residents’ preferences regarding participation in investment financing costs were also examined. Surveys carried out show that the inhabitants of the commune support renewable energy sources and some of the respondents are willing to partially subsidize them. The research has shown that there is a correlation between the age, education and income of the respondents and the amount of co-financing declared by them for the construction of a wind farm in the commune of Rajgród. The largest group of people willing to finance the investment were people in the age groups 26-40 and 41-65. The declared willingness to finance the investment was 1,86 EUR (10% of people) and 2,33 EUR (15% of people). These were people aged between 41-65 with their income of over 232,56 EUR. Only 2% of the respondents declared the amount of 1,16 EUR and they were people over 65 years of age with an average monthly income of about 116,28 EUR.
Źródło:
Ekonomia i Środowisko; 2018, 2; 124-141
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing the Petra Garden and Pool Complex chronology through the ceramics
Autorzy:
Koulianos, Pamela K
Powiązania:
https://bibliotekanauki.pl/articles/2033327.pdf
Data publikacji:
2021-12-31
Wydawca:
Uniwersytet Warszawski. Wydawnictwa Uniwersytetu Warszawskiego
Tematy:
pottery
Nabataean
Roman
Coarse wares
Nabataean Painted Fine Ware
Petra Garden and Pool Complex
Opis:
The Petra Garden and Pool Complex in the ancient city center has been dated based on stratigraphy and an array of diagnostic finds. The present study of the coarse wares from selected contexts at the site (augmented by amphorae and fine wares) aims to show corroborative evidence from the ceramic assemblage to support the dating of three major phases in the history of the complex: the construction of the monumental Nabataean garden and pool complex in the end of the 1st century BCE, the Roman renovations in the early 2nd century CE and, last but not least, the second destruction that ended the occupation of the complex, most probably at the end of the 6th century CE. The overall purpose of this paper is to contribute to the knowledge of Petra coarse-ware pottery from the Nabataean and Roman periods.
Źródło:
Polish Archaeology in the Mediterranean; 2021, 30(2); 611-628
1234-5415
Pojawia się w:
Polish Archaeology in the Mediterranean
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the phytotoxicity of filter backwash water coagulation products from a pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/207079.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phytotptpxicity
swimming pool water
coagulation process
Lepidium sativum
Lemna minor
fitotoksyczność
woda basenowa
proces koagulacji
Opis:
The possibility of using the process of coagulation for purifying the filter backwash water from a swimming pool water system has been presented. The assessment of the process efficiency based on the physicochemical parameters was extended by a phytotoxicity analysis of products (sludges and supernatant liquids) obtained from the coagulation processes. The phytotoxicity of sludges was examined with respect to garden cress (Lepidium sativum) and white mustard (Sinapis alba), while duckweed (Lemna minor) was used for studying liquids. Coagulation process was highly effective in purifying backwash water when the lowest of the studied aluminum coagulant doses (from 7 to 20 mg/dm3) was used. Moreover, the phytotoxicity assessment of backwash water allowed the determination of the hazard toward plants, which would be posed by using the backwash water for plant irrigation. The high stimulation of the growth of plant indices, observed in samples with raw backwash water, was caused by nutritive nitrogen and phosphorus. Their removal, in the case of postcoagulation solutions, significantly contributed to the inhibition of plant growth. In turn, sludges derived from both raw washings and coagulation exhibited phytotoxicity.
Źródło:
Environment Protection Engineering; 2018, 44, 4; 43-56
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Straty strumienia ciepła z powierzchni wody w basenach do kontrolowanego chowu ryb ciepłolubnych
Losses of heat stream from the surface of water in pools for controlled breeding of thermophilous fish
Autorzy:
Żelazny, H.
Powiązania:
https://bibliotekanauki.pl/articles/238999.pdf
Data publikacji:
2007
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
straty strumienia ciepła
basen
kontrolowany chów ryb
heat stream losses
pool
controlled breeding of fish
Opis:
Celem badań było oszacowanie strat strumienia ciepła suchego i mokrego z powierzchni basenów do przemysłowego chowu ryb ciepłolubnych. Pomiary parametrów cieplno-wilgotnościowych powietrza i wody w zbiornikach produkcyjnych przeprowadzono w czterech eksploatowanych pomieszczeniach fermowych. Uzyskano duże zróżnicowanie wartości strumienia ciepła traconego do otoczenia, przy czym zdecydowanie większy udział miał strumień ciepła mokrego. Do inżynierskich obliczeń mocy urządzenia podgrzewającego wodę cyrkulującą w basenach zaproponowano przyjmować straty strumienia ciepła o gęstości 100 W/m2.
The research aimed at estimating the losses of dry and wet heat stream from water surface of the pools for industrial breeding of thermophilous fish. The measurements of thermal and moisture parameters of the air and water in production reservoirs were conducted in four exploited livestock rooms. Measured values of heat stream lost to the surroundings were strongly differentiated and much larger part of the stream consisted of the wet heat. For engineering calculations of power necessary for the device heating up the water circulating in pools, an assumption of heat stream losses of 100 W/m2 density was proposed.
Źródło:
Problemy Inżynierii Rolniczej; 2007, R. 15, nr 1 cz.2, 1 cz.2; 115-121
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania możliwości zagospodarowania popłuczyn z obiegów basenowych
The study of possibilities of washings reusing from swimming pool circulation systems
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125784.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
popłuczyny
obieg basenowy
zagospodarowanie popłuczyn
sedymentacja
washings
swimming pool water circulation system
washings reusing
sedimentation
Opis:
Baseny to bardzo drogie pod względem eksploatacji obiekty sportowe, dlatego też osoby zarządzające tymi obiektami szukają sposobów na obniżenie kosztów ich użytkowania. Jednym z nich jest zagospodarowanie popłuczyn dotychczas odprowadzanych do kanalizacji sanitarnej. Oceny możliwości zagospodarowania popłuczyn odprowadzanych z filtracyjnych instalacji basenowych dokonano na podstawie dopuszczalnych wartości podstawowych wskaźników zanieczyszczeń w ściekach odprowadzanych do wód i ziemi (pH temperatura, zawiesiny ogólne, ChZT, BZT5, Pog, Nog, chlor wolny). Badania jakości popłuczyn z 26 basenów wykazały, że ich jakość jest zależna od warunków eksploatacji danego obiegu basenowego, m.in. długości cyklu filtracyjnego i rodzaju złoża. Parametrami uniemożliwiającymi bezpośrednie zagospodarowanie popłuczyn były zbyt duża zawartość zawiesin ogólnych (≥ 35 mg/dm3) oraz stężenie chloru wolnego (≥ 0,2 mg Cl2/dm3). Jakość wód nadosadowych powstałych w wyniku sedymentacji popłuczyn wskazuje na ich przydatność do zagospodarowania. Zastosowanie w obiektach basenowych odstojników popłuczyn umożliwiłoby odciążenie systemów kanalizacji i odpływ wód nadosadowych do wód powierzchniowych lub ich wykorzystanie do nawadniania terenów zielonych w sposób bezpieczny dla środowiska.
Swimming pools are very expensive in terms of exploitation sports facilities, therefore managers of these facilities are looking for methods of reducing the costs of their use. One of the proposed method is the managing of washings previously discharged to the sanitary sewage system. The assessment of possibilities of washings reusing from swimming pool filtration system is based on the limits of basic indicators of pollutants in wastewater discharged to water and soil (temperature, pH, TSS, BOD5, COD, TN, TP, free chlorine). The conducted research of washings quality from 26 tested swimming pools have shown that washings quality is dependent on the operating conditions of the circuit pool, including the filter cycle duration and types of filter bed. The parameters which prevents direct management washings were too high content of total suspended solids (≥ 35 mg/dm3) and the concentration of free chlorine (≥ 0.2 mg Cl2/dm3). Quality washings subjected to sedimentation indicates its usefulness for rational management. The application in swimming pools settling tanks allows discharge sewage systems and drainage supernatants to surface waters or using to irrigation green areas in an environmentally safe way.
Źródło:
Proceedings of ECOpole; 2015, 9, 2; 803-813
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problematyka uzyskiwania i wykonywania praw z patentu z perspektywy prawa ochrony konkurencji ze szczególnym uwzględnieniem sektora farmaceutycznego
Autorzy:
Anusz, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/2216137.pdf
Data publikacji:
2022-01-10
Wydawca:
Uniwersytet Warszawski. Wydawnictwo Naukowe Wydziału Zarządzania
Tematy:
prawo patentowe
prawo antymonopolowe
smoke-screen patenting
gąszcze patentowe
zasoby patentowe
patent pool
trolling patentowy
Opis:
Artykuł omawia problematykę uzyskiwania i wykonywania praw z patentu z perspektywy prawa antymonopolowego w celu rozstrzygnięcia czy proces uzyskiwania praw z patentu może stanowić praktykę o celu lub skutku antykonkurencyjnym oraz w jaki sposób możliwe jest naruszanie prawa antymonopolowego poprzez wykonywanie praw z patentu. W przypadku praktyk uzyskiwania praw z patentu artykuł prowadzi do wniosku, że działania przedsiębiorców w procesie uzyskiwania praw z patentu mogą stanowić naruszenie ustawy antymonopolowej. Praktyki te mogą być sankcjonowane na podstawie uokik, niemniej ze względu na specyfikę procedury uzyskiwania praw z patentu, tzn. procedury toczącej się przed Urzędem Patentowym, skuteczniejszym rozwiązaniem może być wyposażenie Urzędu Patentowego w kompetencję interwencji w razie wystąpienia praktyk antykonkurencyjnych w procesie uzyskiwania praw z patentu. W odniesieniu do praktyk antykonkurencyjnych związanych z wykonywaniem praw z patentu regulacje antymonopolowe należy uznać za wystarczające, podkreślając konieczność zaistnienia naruszenia interesu publicznego jako czynnika szczególnie istotnego w przypadku wykonywania i uzyskiwania praw z patentu.
Źródło:
internetowy Kwartalnik Antymonopolowy i Regulacyjny; 2022, 11, 1; 33-44
2299-5749
Pojawia się w:
internetowy Kwartalnik Antymonopolowy i Regulacyjny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of solar collectors on the example of a water-park. Part 1: Technical analysis
Wykorzystanie kolektorow slonecznych na przykladzie parku wodnego. Cz. 1: Analiza techniczna
Autorzy:
Tucki, K.
Powiązania:
https://bibliotekanauki.pl/articles/793132.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
solar collector
technological analysis
modernization
energy system
water park
heating system
swimming pool
venting system
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2016, 16, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The short IPIP-BFM-20 questionnaire for measuring the Big Five
Autorzy:
Topolewska, Ewa
Skimina, Ewa
Strus, Włodzimierz
Cieciuch, Jan
Rowiński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2128259.pdf
Data publikacji:
2019-04-04
Wydawca:
Katolicki Uniwersytet Lubelski Jana Pawła II. Towarzystwo Naukowe KUL
Tematy:
the Big Five
short version of the questionnaire
personality
personality traits
International Personality Item Pool
Opis:
The most frequently used measures of personality consist of a large number of items. However, it is their short versions that have enjoyed popularity in recent years. This article is a presentation of the short form of Goldberg’s questionnaire for measuring the Big Five personality traits. The questionnaire measures five traits (Extraversion, Agreeableness, Conscientiousness, Emotional Stability, Intellect), and consists of 20 items. It is a shortened version of the 50-item Big Five Markers questionnaire from the resources of the International Personality Item Pool, whose Polish version was prepared by Strus, Cieciuch, and Rowiński (2014b). In constructing the short version, we followed the procedure developed by Donnellan and colleagues (2006), aimed at maximizing the internal consistency and independence of scales. The research was carried out on a group of N = 903 people aged between 16 and 83 years. The validity (verified in confirmatory factor analysis and in the analysis of correlations between the questionnaire’s scales and other measures of the five personality traits) and reliability (measured by Cronbach’s alpha coefficient) are satisfactory and make the questionnaire fit for use in scientific research.
Źródło:
Roczniki Psychologiczne; 2014, 17, 2; 385-402
1507-7888
Pojawia się w:
Roczniki Psychologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O potrzebie regulacji umów o współdziałanie
On the need to regulate cooperation agreements in the Polish Civil Code
Autorzy:
Klaja, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/1026546.pdf
Data publikacji:
2020-09-24
Wydawca:
Katolicki Uniwersytet Lubelski Jana Pawła II
Tematy:
umowy o współdziałanie
spółka cywilmna
joint venture
konsorcjum
pool
cooperation agreements
civil law partnership
consortium,
Opis:
Przedmiotem publikacji jest problematyka umów o współdziałanie. W artykule dokonano krytycznej oceny aktualnego stanu regulacji, a także podjęto próbę określenia cech wspólnych oraz umiejscowienia form współdziałania w systemie prawa cywilnego poprzez delimitację przedmiotowych umów i typowych umów zobowiązaniowych, a także odwołanie się do prawa osobowego. Publikacja stanowi głos w dyskusji nad założeniami przyszłej regulacji umów o współdziałanie w Kodeksie cywilnym.
The subject of this article is the issue of cooperation agreements under Polish law. The article presents a critical assessment of the current legal regulation. It focuses on attempts to determine characteristic features and to place cooperation agreements in the civil law system by distinguishing between cooperation and typical agreements, as well as referring to the personal civil law. The publication is a voice in the discussion on the assumptions of the future regulation of cooperation agreements in the Polish Civil Code.
Źródło:
Przegląd Prawno-Ekonomiczny; 2019, 4; 87-98
1898-2166
Pojawia się w:
Przegląd Prawno-Ekonomiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu systemu cyrkulacji na poziom stężeń mikrozanieczyszczeń w układzie oczyszczania wody basenowej
The impact of the circulation system on the concentration levels of micropollutants in the swimming pool water treatment system
Autorzy:
Lempart, A.
Kudlek, E.
Dudziak, M.
Szyguła, A.
Powiązania:
https://bibliotekanauki.pl/articles/399926.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
system oczyszczania
woda basenowa
cyrkulacja wody
PPCPs
mikrozanieczyszczenia
pool water
treatment system
water circulation
micropollutants
Opis:
Każda instalacja basenowa powinna zapewniać prawidłową i stałą cyrkulację wody w systemie obiegu zamkniętego, która umożliwia przedłużenie czasu całkowitej wymiany wody nawet do 1 roku. Praca takiego systemu może jednak potencjalnie powodować podwyższenie stężenia małocząsteczkowych mikrozanieczyszczeń w układzie oczyszczania wody basenowej. Celem niniejszej pracy jest potwierdzenie lub odrzucenie niniejszej tezy. W ramach badań wstępnych przeprowadzono analizę zawartości substancji organicznych i nieorganicznych w wodzie basenowej na podstawie wskaźników ogólnych takich jak OWO, absorbancja UV254 i przewodność właściwa. W zasadniczym etapie badań, próbki wody basenowej pobierane z czterech różnych punktów instalacji zostały poddane analizie chromatograficznej w celu oznaczenia małocząsteczkowych mikrozanieczyszczeń organicznych. Badaniu poddano także wodę wodociągową stosowaną do napełnienia niecki i regularnego uzupełniania strat objętości. Badanie to miało na celu wykluczenie wody wodociągowej jako potencjalnie możliwego źródła pochodzenia zanieczyszczeń w wodzie basenowej. Przeprowadzone badania wstępne wykazały niemal dwukrotny wzrost zawartości ogólnego węgla organicznego oraz absorbancji UV254 po sześciu miesiącach, co niewątpliwie świadczy o możliwości gromadzenia się zanieczyszczeń organicznych w systemach cyrkulacji wody basenowej. Tego zjawiska nie zaobserwowano w przypadku związków nieorganicznych. W wyniku analiz chromatograficznych w wodzie basenowej oznaczono farmaceutyki i pozostałości kosmetyków. Stwierdzono, że w układzie oczyszczania wody basenowej miejscem największego gromadzenia się farmaceutyków jest zbiornik przelewowy, a pozostałości kosmetyków niecka basenowa. Na omawiane zjawisko ma wpływ czas trwania filtrocyklu.
Each pool installation should ensure proper and constant circulation of water in a closed circuit system. However, the operation of such a system can potentially cause the accumulation of small -molecule micropollutants in the pool water treatment system. The aim of this work is to confirm or reject this argument. As part of preliminary tests, the content of organic and inorganic substances in swimming pool water was analyzed based on general indicators such as TOC, UV254 absorbance and conductivity. In the main stage of the research, pool water samples collected from four different points of the swimming pool installation were subjected to chromatographic analysis to determine the small-molecule micropollutants. The tap water used to fill the basin and regular replenishment of volume losses was also tested. This study was intended to exclude the tap water as a potential source of contamination in the pool water. Preliminary studies have shown almost a two-fold increase in the total organic carbon content and absorbance UV254 at the turn of six months, which undoubtedly indicates the accumulation of organic pollutants in pool water circulation systems. It was not observed in the case of inorganic compounds. As a result of the chromatographic analyzes of the pool water, the content of pharmaceuticals and personal care product was determined. It was found that the compensation tank is the place of the highest accumulation of the tested pharmaceuticals in the pool water treatment system , while the cosmetics component accumulated in the pool basin to the greatest degree. It was affected by the duration of the filter cycle.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 2; 23-31
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instytucje i środowisko
Institutions and the Environment
Autorzy:
Ostrom, Elinor
Powiązania:
https://bibliotekanauki.pl/articles/903811.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Ekonomiczny w Krakowie, Małopolska Szkoła Administracji Publicznej
Tematy:
zasoby wspólne
reguły instytucjonalne
wspólnoty
adaptacja
eksploatacja
common-pool resources
institutional rules
adaptation
exploitation
communities
Opis:
W swoim artykule Elinor Ostrom przedstawia krytyczną analizę wyników wielu badań empirycznych, współczesnej teorii gier i własnych eksperymentów z dziedziny projektowania instytucji w odniesieniu do nadmiernej eksploatacji zasobów wspólnych. Autorka wskazuje na fakt, iż mając możliwość porozumiewania się, eksperymentowania i modyfikacji reguł instytucjonalnych, ludzie wypracowują różnorodne − niekoniecznie rynkowe − rozwiązania prowadzące do zrównoważonego zarządzania dobrami wspólnymi, do których rzekomo ma zastosowanie pojęcie "tragedii wspólnego pastwiska".
In her article, Elinor Ostrom offers a critical account of a number of empirical studies, game-theoretic analyses and her own experiments in institutional design as applicable to the issue of overexploitation of common-pool resources. She argues that, given people's ability to communicate, experiment and modify institutional rules, they can develop various − not necessarily market-based − solutions with a view to achieving sustainable management of such resources to which the concept of the tragedy of the commons supposedly applies.
Źródło:
Zarządzanie Publiczne / Public Governance; 2012, 2(20); 83-99
1898-3529
2658-1116
Pojawia się w:
Zarządzanie Publiczne / Public Governance
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The short IPIP-BFM-20 questionnaire for measuring the Big Five
Autorzy:
Topolewska, Ewa
Skimina, Ewa
Strus, Włodzimierz
Cieciuch, Jan
Rowiński, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2128183.pdf
Data publikacji:
2019-04-04
Wydawca:
Katolicki Uniwersytet Lubelski Jana Pawła II. Towarzystwo Naukowe KUL
Tematy:
the Big Five
short version of the questionnaire
personality
personality traits
International Personality Item Pool
Opis:
The most frequently used measures of personality consist of a large number of items. However, it is their short versions that have enjoyed popularity in recent years. This article is a presentation of the short form of Goldberg’s questionnaire for measuring the Big Five personality traits. The questionnaire measures five traits (Extraversion, Agreeableness, Conscientiousness, Emotional Stability, Intellect), and consists of 20 items. It is a shortened version of the 50-item Big Five Markers questionnaire from the resources of the International Personality Item Pool, whose Polish version was prepared by Strus, Cieciuch, and Rowiński (2014b). In constructing the short version, we followed the procedure developed by Donnellan and colleagues (2006), aimed at maximizing the internal consistency and independence of scales. The research was carried out on a group of N = 903 people aged between 16 and 83 years. The validity (verified in confirmatory factor analysis and in the analysis of correlations between the questionnaire’s scales and other measures of the five personality traits) and reliability (measured by Cronbach’s alpha coefficient) are satisfactory and make the questionnaire fit for use in scientific research.
Źródło:
Roczniki Psychologiczne; 2014, 17, 2; 385-402
1507-7888
Pojawia się w:
Roczniki Psychologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A circular pool in the main courtyard of the “Hellenistic” House in Nea Paphos. Preliminary remarks
Autorzy:
Romaniuk, Marcin M.
Powiązania:
https://bibliotekanauki.pl/articles/1684164.pdf
Data publikacji:
2018-07-09
Wydawca:
Uniwersytet Warszawski. Wydawnictwa Uniwersytetu Warszawskiego
Tematy:
Nea Paphos
“Hellenistic” House
peristyle
circular pool
fishpond
piscina
Dressel 6A amphora
labrum
garden
Opis:
Excavations in the main courtyard of the “Hellenistic” House in Nea Paphos in 2016, Polish excavations, revealed a small circular pool with immured tops of Dressel 6A amphorae in the wall surrounding it and a circular imprint in the middle of the floor. The paper undertakes a discussion of possible form and function, putting forward a tentative interpretation based on a study of parallels that we are dealing with an ornamental pool, a popular furnishing of wealthy Roman house gardens, functioning perhaps as a fishpond (piscina) or a tank with water constantly running in and out, with a labrum or columnar pedestal standing in the middle.
Źródło:
Polish Archaeology in the Mediterranean; 2017, 26(1); 429-440
1234-5415
Pojawia się w:
Polish Archaeology in the Mediterranean
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości zrzutu popłuczyn z obiektu basenowego do rzeki
Analysis of the possibility of washings discharge from the swimming pool to the river
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/127336.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
basen
popłuczyny
klasa czystości rzeki
sedymentacja
koagulacja
swimming pool
washings
cleanliness class of river
sedimentation
coagulation
Opis:
W pracy przedstawiono wyniki badań, na podstawie których określono możliwość odprowadzenia popłuczyn, powstałych w wyniku płukania złóż filtracyjnych w systemie oczyszczania wody basenowej, do pobliskiej rzeki. Na podstawie analiz fizyczno-chemicznych próbek popłuczyn określono stopień ich zanieczyszczenia. Wyniki badań porównano z zaleceniami dotyczącymi dopuszczalnego stopnia zanieczyszczeń w ściekach odprowadzanych do wód lub ziemi (DzU 2014, poz. 1800) i wymaganiami pozwolenia wodnoprawnego wydanymi dla analizowanego obiektu basenowego. Analiza wyników badań popłuczyn surowych (niepoddanych obróbce) wykazała, że bezpośrednie ich odprowadzenie do rzeki jest niemożliwe przede wszystkim ze względu na duże stężenie chloru wolnego oraz ilość zawiesin ogólnych. Analiza wyników badań popłuczyn poddanych procesowi sedymentacji lub koagulacji objętościowej w warunkach laboratoryjnych pozwoliła zaprojektować system odprowadzenia wody nadosadowej do rzeki. Warunkiem „zrzutu” wody nadosadowej do rzeki będzie konieczność zastosowania zbiornika buforowego, osadnika lub systemu wspomagającego sedymentację zawiesin w popłuczynach np. poprzez zastosowanie koagulacji objętościowej, a następnie odprowadzanie zagęszczonych ścieków do kanalizacji sanitarnej.
The paper presents the results of studies on determining of the possibility of discharge washings, as a result of rinse filter beds in the swimming pool water treatment system, to the river. Based on the physical and chemical analysis of washings samples the degree of their contamination was determined. The results were compared with the recommended acceptable level of pollutants in wastewater discharged to water or soil (OJ 2014, item 1800) and with the requirements of the water permit issued for the analyzed swimming pool. The obtained results for raw washings (untreated) showed that direct discharge of washings into the near located river is impossible, especially due to the high concentration of free chlorine and the amount of total suspended solids (TSS). Analysis of the results of washings subjected to the process of sedimentation or coagulation in the laboratory helped design the system supernatant water drain into the river. The condition of such management would be to use a buffer tank, settling tank or supporting system to sedimentation of suspended solids, e.g. the use of coagulation and then the draining of concentrated sewage into the sanitary sewage system.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 325-331
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltration for Purification and Treatment of Water Streams in Swimming Pool Circuits
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125442.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
swimming pool water
pressure driven
membrane processes
closed circuit
water systems
water treatment systems
water recovery
Opis:
The paper presents possible applications of pressure-driven membrane processes for treatment of swimming pool water and purification of waste streams – washings. Newly identified swimming pool water quality issues are presented that require a modernization of existing technologies. The studies used polymer membranes with the same particle distribution range (50000 Da), but made of different membrane-forming materials: polyvinylidene difluoride (PVDF) and polyether sulfone (PES) for purification of washings. The ultrafiltration process allowed obtaining a high turbidity reduction rate in washings (over 95%), and also a significant reduction of total organic carbon. The effectiveness of the PES membrane was reduced after the process commencement, whereas the separation capacity of the PVDF membrane increased during the studied filtration process. While setting the operational process parameters consideration should be given also to the resistance of used membranes to chlorine present in the swimming pool water. A prolonged exposure of the polyether sulfone membrane to chloride may have caused its gradual damage and degradation of its separation properties.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 38-44
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczna żelbetowej konstrukcji basenu sportowego
Numerical analysis of the reinforced concrete structure of a sports pool
Autorzy:
Skierka, Beata
Domski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2081886.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
konstrukcja żelbetowa
analiza numeryczna
obciążenie
modernizacja
swimming pool
reinforced concrete structure
numerical analysis
load
modernization
Opis:
W artykule przedstawiono analizę numeryczną istniejącego basenu. Analiza obejmowała trzy warianty obciążeniowe związane z jego modernizacją. Pierwszy przypadek obciążeń dotyczył rzeczywistej pracy basenu przed modernizacją. Natomiast dwa kolejne przypadki obciążeń obejmowały możliwe oddziaływania na basen po modernizacji. W wyniku przeprowadzonych analiz stwierdzono, że modernizacja basenu związana ze zmianą jego obciążenia, nie spowoduje przekroczenia jego stanów granicznych.
The article presents the numerical analysis of the existing swimming pool. The analysis included three load variants related to the pool modernization. The first load case was related to the actual operation of the pool before its modernization. Next, two subsequent load cases included possible impacts on the swimming pool after its modernization. As a result of the conducted analyzes, it was found that the modernization of the swimming pool will not result in exceeding its limit states.
Źródło:
Przegląd Budowlany; 2022, 93, 3-4; 89--94
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Disinfection By-Products in Swimming Pool Water and Possibilities of Limiting Their Impact on Health of Swimmers
Produkty uboczne dezynfekcji wody basenowej i możliwości ograniczania ich wpływu na zdrowie użytkowników
Autorzy:
Ratajczak, Katarzyna
Piotrowska, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/385396.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
uzdatnianie wody basenowej
THM
produkty uboczne dezynfekcji wody
wentylacja
treatment of swimming pool water
DBPs
ventilation
Opis:
Obecność produktów ubocznych dezynfekcji wody (DBPs) w środowisku basenowym jest zagrożeniem dla zdrowia użytkowników pływalni. Z uwagi na mechanizm formowania DBPs nie jesteśmy w stanie zapobiec ich powstawaniu. Istnieje jednak kilka możliwości zapobiegania szkodliwemu wpływowi DBPs na zdrowie użytkowników basenów, wśród których należy wymienić różne rodzaje metod redukcji prekursorów chloru związanego i DBPs oraz nowe podejście do projektowania rozdziału powietrza wentylacyjnego.
The presence of water disinfection by-products (DBPs) in the pool environment is a threat to the health of the users of swimming pools. Due to the mechanism of DBP formation, we are not able to prevent their presence. However, there are several ways to prevent the harmful effects of DBPs on the health of pool users; among these, various kinds of methods that result in the reduction of combined chlorine and DBPs precursors should be mentioned. And last but not least, a new approach to the design of the ventilation system for indoor swimming pools seems to be crucial for the above-mentioned purpose.
Źródło:
Geomatics and Environmental Engineering; 2019, 13, 3; 71-92
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geotermia na przykładzie tarnowskich term w Tarnowie Podgórnym
Geothermics on the example of tarnowskie termy in Tarnowo Podgórne
Autorzy:
Trzepierczyński, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/115283.pdf
Data publikacji:
2018
Wydawca:
Wyższa Szkoła Techniczna w Katowicach
Tematy:
geotermia
dolna jura
basen sportowo-rekreacyjny
perspektywy geotermii
geothermics
Lower Jurassic
competition and recreation swimming pool
perspectives
Opis:
Polska posiada największe zasoby energii geotermalnej względem innych rodzajów energii odnawialnej. Energia geotermalna jest niezależna od warunków klimatycznych i atmosferycznych. Z końcem ubiegłego wieku w naszym kraju rozpoczęto prace badawcze poszukiwania i oszacowania zasobów wód geotermalnych, wskazano perspektywy ich wykorzystania oraz rozpoczęto budowę zakładów geotermalnych. Autor artykułu opracował możliwości pozyskania energii wód geotermalnych dla celów rekreacyjno-balneologicznych dla Tarnowa Podgórnego w Wielkopolsce. Na podstawie badań geologicznych autora wykonano projekt wiercenia, następnie dokumentację hydrogeologiczną, zaprojektowano i wybudowano ośrodek rekreacyjny Tarnowskie Termy otwarty w maju 2015 r. W artykule wskazano na rolę wyprzedzających badań geologicznych dla efektów poszukiwania wód geotermalnych. W Tarnowie Podgórnym nawiercono w utworach dolnojurajskich na głębokości 810-1170 m p.p.t. wodę geotermalną o wydajności 220m3/h, temperaturze 44°C i mineralizacji 80g/l. Tarnowskie Termy to 2 baseny geotermalne wewnętrzny i zewnętrzny, basen rekreacyjny oraz basen sportowy i do nauki pływania. Woda chlorkowo-sodowa z zawartością pierwiastków: J, Ba, Mg, Ca, F, Cu, Fe stwarza perspektywy do rozwoju balneologii. Dziennie w Tarnowskich Termach przebywa około 1500 ludzi. Obecnie po pewnym zastoju nastąpił w naszym kraju wzrost zainteresowania wykorzystaniem energii geotermalnej dla ciepłownictwa, rekreacji a nawet produkcji energii elektrycznej. Przełamano zastój budowy zakładu geotermalnego w Toruniu oraz zatwierdzono do realizacji wykonanie odwiertów geotermalnych na Podhalu, w Kole, Lądku Zdroju, Sochaczewie i Sieradzu. Problematykę wykorzystania energii geotermalnej powinno się również reaktywować w Górnośląskim Zagłębiu Węglowym.
Great resources of geothermal energy in relation to other types of renewable energy there are in Poland. Geothermal energy is independent of climate and weather conditions. At the end of the past century, research for geothermal water condition and construction of geothermal plants were started in our country and then, their resources were estimated and the options of their use were determined. Possibilities for acquisition of geothermal water energy for recreation and balneology purposes in Tarnowo Podgórne in Wielkopolska Region of Poland were presented in this article. On the basis of the author's geological research, project of drilling and hydrogeological documents were prepared and then, the recreation centre "Tarnowskie Termy" was designed and built. Opening of the centre took place in May 2015. The article points out the role of leading geological research for the effects of searching for geothermal water. Geothermal water with the flow rate of 220m3/h, 44°C of temperature and 80g/l mineralization was extracted in Tarnowo Podgórne in Lower J urassic formations at the depth of 810-1170 m b.g.l. Tarnowskie Termy consist of 2 geothermal pools - an indoor and an outdoor pool, a pool for recreation swimming, a competition pool and a pool for learning swimming. Sodium chloride water with I, Ba, Mg, Ca, F, Cu, Fe elements provides perspectives for development of balneotherapy. Each day, 1,500 people spend time in Tarnowskie Termy. Currently, after some stagnation, a growth of interest in using geothermal energy for heat engineering, recreation and even electrical energy production has been observed in our country. The construction of geothermal plant in Toruń was resumed, and drilling of geothermal boreholes in Podhale, Koło, Lądek Zdrój, Sochaczew and Sieradz was accepted for accomplishment. The question of geothermal energy use should be also revived in Upper Silesian Coal Basin.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach; 2018, 10; 49-63
2082-7016
2450-5552
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the possibility of recycling backwashing water from the swimming pool water treatment system
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/388489.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
swimming pool water
backwashing
toxicological assessment
physicochemical analysis
biotests
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
Opis:
The paper presents the physicochemical analysis and toxicological assessment of backwashing samples taken after the process of washing filter beds in a raw condition after the process of their aeration and dechlorination. The backwash water under investigation originated from circulation systems existing in two indoor swimming pool facilities. The backwash water, as used at the preliminary and the main stages, was characterized by different physicochemical properties. For toxicological assessment, the Mictorox® bioluminescence inhibition test, the Chaoborus sp. insect larva survival test and the phyto test using Lemna minor fine cilium were involved. The investigation presented in the paper included a preliminary phase focusing on the ecotoxic characterization of backwash water subjected to aeration and dechlorination processes. In turn, at the main stage, the effect of aeration duration on the quality of backwash water in terms of its physicochemical parameters was analyzed. The results of the preliminary stage investigation indicate that backwash water, both in a raw condition and after 30 minutes’ aeration, could not be discharged directly to the environment due to the threat to living organisms caused by its high toxicity. Whereas, using 160 minutes’ aeration duration contributed to a significant improvement in the quality of the backwash water and elimination of its toxic properties with respect to the indicator organisms used. The chemical dechlorination process brought about varying effects. In the case of the Microtox® test, a stimulation of bacterial bioluminescence was noted, but, at the same time, the death of individual insect larva specimens was observed. In spite of the high biomass increase in the Lemna minor test, a gradual discolouration of fronds under the influence of backwash water was observed. Because of the presence of numerous compounds being disinfection by-products, as well as coagulant residues in backwash water deriving from swimming pool systems, it is necessary to seek further solutions that will allow them to be recycled, which will result in a reduction of water consumption and effluent discharges.
W pracy przedstawiono analizę fizykochemiczną oraz ocenę toksykologiczną próbek popłuczyn pobranych po procesie płukania złóż filtracyjnych w stanie surowym po procesie napowietrzania oraz dechloracji. Badane popłuczyny pochodziły z obiegów zlokalizowanych w dwóch obiektach basenowych krytych. Do oceny toksykologicznej włączono test inhibicji bioluminescencji Mictorox®, przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania obejmowały fazę wstępną, skupiającą się na charakterystyce ekotoksykologicznej popłuczyn poddanych procesom dechloracji oraz napowietrzania. W etapie zasadniczym badań analizowano dodatkowo wpływ czasu napowietrzania na jakość popłuczyn pod względem parametrów fizykochemicznych. Wyniki wstępnego etapu badań sygnalizuj ą, że popłuczyny zarówno w stanie surowym, jak i po 30-minutowym napowietrzaniu nie mogły zostać bezpośrednio odprowadzone do środowiska ze względu na zagrożenie dla organizmów żywych, spowodowane ich wysoką toksycznością. Natomiast zastosowane wydłużenie czasu napowietrzania (160 min) przyczyni ło się do znaczącej poprawy jakości popłuczyn i pozbawienia ich właściwości toksycznych w stosunku do wykorzystanych organizmów wskaźnikowych. Zróżnicowane efekty przyniósł zabieg chemicznej dechloracji. W przypadku testu Microtox® odnotowano stymulację bioluminescencji bakterii, równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem użytych popłuczyn. Niezbędne jest poszukiwanie dalszych rozwiązań umożliwiających ich recykling, co zapewni ograniczenie zużycia wody oraz odprowadzania ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 4; 401-410
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jubileusz 65 lat działalności pływalni w Pałacu Młodzieży w Warszawie
65-year jubilee of swimming pool in the Palace of Youth in Warsaw
Autorzy:
Krynicki, Bartłomiej
Pawlikowska-Piechotka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2044434.pdf
Data publikacji:
2021
Wydawca:
Mazowieckie Biuro Planowania Regionalnego w Warszawie
Tematy:
historia architektury
historia sportu
PKiN Warszawa
pływalnia
history of architecture
history of sport
PKiN Warsaw
swimming pool
Opis:
Pałac Młodzieży w Warszawie został oddany do użytku 65 lat temu, w kwietniu 1955 r., jako część gmachu Pałacu Kultury i Nauki, wzniesionego w stylu socrealizmu. Był wówczas niezwykłą atrakcją, oferując dzieciom nieosiągalne gdzie indziej możliwości rozwoju pasji i zainteresowań. Na przykład, kryta pływalnia w Pałacu Młodzieży była i jest nadal jedyną pływalnią w województwie mazowieckim, na której jest możliwe uprawianie skoków do wody. Jest to jednocześnie jedna z kilku pływalni w Polsce, na której można uprawiać tę dyscyplinę w pełnym zakresie konkurencji przez cały rok. W 2007 r. wpisano Pałac Kultury i Nauki wraz z otoczeniem (Plac Defilad) do rejestru zabytków. Prace modernizacyjne, które miały miejsce w Pałacu Młodzieży, w tym na pływalni PM-PKiN, musiały uwzględnić bardzo restrykcyjne i szczegółowe rekomendacje programu konserwatorskiego, narzucającego zachowanie historycznych walorów stylu architektonicznego pływalni. Oddana w 2016 r. ponownie do użytku po zabiegach renowacyjnych pływalnia w PM-PKiN służy obecnie sekcji pływackiej (zajęcia: piłka wodna, skoki do wody, pływanie, aerobik).
The Palace of Youth in Warsaw was opened 65 years ago, in April 1955, as a part of the Palace of Culture and Science building (PKiN), erected in the style of socialist realism. At that time, it was an extraordinary attraction, offering children unattainable elsewhere opportunities to develop their passions and interests. For example, the indoor swimming pool at the Palace of Youth was (and still is) the only swimming pool in the Masovian Voivodeship where diving is possible. At the same time, it is one of the few swimming pools in Poland where this discipline can be practiced in the full range of competition throughout the year. In 2007, the Palace of Culture and Science and its surroundings (Parade Square) entered into the register of historic monuments. The modernization works that took place in the Palace of Youth, including PM-PKiN swimming pool, had to take into account very restrictive and detailed recommendations of the conservation program, which imposed preservation of the historical values of architectural style of the swimming pool. The swimming pool at PM-PKiN, which was reopened in 2016 after renovation, is now used by the swimming section (activities: water polo, diving, swimming, aerobics).
Źródło:
MAZOWSZE Studia Regionalne; 2021, 37; 131-152
1689-4774
Pojawia się w:
MAZOWSZE Studia Regionalne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125768.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
integrated process
washings nanofiltration
coagulation
swimming pool water installation
Opis:
Przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu: koagulacja-sedymentacja-nanofiltracja do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5-3,0 mg Al/dm3) oraz sedymentacji (przy czasie trwania 0,5-24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mg Al/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Cząsteczki osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, przy wyższej dawce koagulantu (3,0 mg Al/dm3), równocześnie spowodowały stopniowy wzrost zdolności separacyjnych membrany i utworzenie tzw. membrany wtórnej. Przy czym charakteryzowała się ona mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5-3.0 mg Al/dm3 and sedimentation where the scope of duration 0.5-24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mg Al/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after Edyta Łaskawiec, Mariusz Dudziak i Joanna 184 Wyczarska-Kokot coagulation with dose 3.0 mg Al/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 177-184
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Salix myrtilloides in north central Poland. Distribution, threats and conservation
Autorzy:
Churski, M
Danielewicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/41057.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Instytut Dendrologii PAN
Tematy:
glacial relict
willow
Polska
locality
habitat loss
Salix myrtilloides
distribution
threat
conservation
habitat protection
gene pool
strategy
Opis:
Present status of a postglacial relict – Salix myrtilloides L. was investigated in north central Poland at 27 localities. Consequently 3 sites were confirmed, 4 were not confirmed, and the remaining 20 were considered to be extinct. In comparison to the historical distribution, ca. 74% of the sites existing 50 years ago do not exist today in the studied region. The confirmed populations were found near Oporówek (ca. 1600 stems), Rakowiec (ca. 100) and Bobrowo (15). At three sites confirmed in this study, the existence of vigorous hybrids between S. myrtilloides and S. aurita L. (S. ×onusta Besser) were observed. The most important threats to Salix myrtilloides L. populations in the studied region were assessed to be hybridization with other commonly occurring willow species, site isolation and habitat destruction. Natural habitat protection with adequate buffer zone and gene pool protection in a form of plantations was suggested as a conservation strategy. As an alternative strategy active protection ‘insitu’ was proposed based on cutting competitive common species of willows.
Źródło:
Dendrobiology; 2008, 60; 3-9
1641-1307
Pojawia się w:
Dendrobiology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Basen wypalonego paliwa
Spent fuel pool
Autorzy:
Rzymkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/214110.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
basen wypalonego paliwa
wypalone paliwo
przechowalnik mokry
spent fuel pond
spent fuel pool
spent fuel
wet storage
Opis:
W opracowaniu przedstawiono podstawowe problemy związane z przechowywaniem zestawów wypalonego paliwa w basenie
The paper presents the basic problems associated with the storage of spent fuel clusters in the pool
Źródło:
Postępy Techniki Jądrowej; 2017, 4; 12-20
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt konstrukcji przekrycia pływalni miejskiej
Design of the shell roof structure of the swimming pool
Autorzy:
Sęk, Anna Małgorzata
Prusiel, Jolanta Anna
Powiązania:
https://bibliotekanauki.pl/articles/162085.pdf
Data publikacji:
2020
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
pływalnia publiczna
przekrycie dachowe
przekrycie cienkościenne
powłoka walcowa
obliczenia statyczne
analiza statyczno-wytrzymałościowa
metoda numeryczna
metoda analityczna
swimming pool
public swimming pool
roof cover
thin-walled covering
cylindrical shell
static calculations
static-strength analysis
numerical method
analitycal method
Opis:
Opracowano koncepcję architektoniczną obiektu pływalni miejskiej z dwoma wariantami konstrukcji przekrycia w postaci powłoki walcowej. Przeprowadzono analizę porównawczą sił wewnętrznych w powłoce uzyskanych metodą numeryczną i analityczną. Zwymiarowano żelbetową konstrukcję przekrycia powłokowego zgodnie z obowiązującymi eurokodami.
The architectural and construction concept of the swimming pool with two types of cylindrical shell roof was designed. A comparative analysis of internal forces using a numerical and analytical method has been carried out. The reinforced structure of cylindrical shell roof has been designed according to required eurocodes.
Źródło:
Przegląd Budowlany; 2020, 91, 5; 43-48
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wody basenowej pływalni krytych oraz kąpielisk sezonowych z wykorzystaniem testu MICROTOX®
Qualitative assessment of water in indoor swimming pool and seasonal bathing resorts using MICROTOX® test
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/400114.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
uboczne produkty dezynfekcji
woda basenowa
biotest bakteryjny
klasyfikacja toksyczności
disinfection by-products
pool water
bacterial bioassays
toxicity classification
Opis:
Przeprowadzone badania miały na celu określenie wielkości efektu toksycznego na podstawie inhibicji bioluminescencji bakterii Aliivibrio fischeri wywołanej przez zanieczyszczenia obecne w próbkach wody basenowej. Wykorzystywanym narzędziem był test Microtox®. Szybkość z jaką uzyskuje się wyniki w tym bioteście pozwala na stosowanie go w stosunku do wielu toksykantów. Ponadto przeprowadzono pomiar absorbancji w nadfiolecie UV254, którego wartość stanowiła parametr zastępczy dla określenia udziału prekursorów ubocznych produktów dezynfekcji w próbkach. Część próbek charakteryzowała się wysokimi wartościami UV254, w przypadku próbki popłuczyn jednego z badanych obiegów wyniosła 144 m-1. Przedstawione w pracy badania jakości wód basenowych obiektów krytych i odkrytych, z zastosowaniem testu Microtox® pozwoliły na potwierdzenie wpływu takich czynników jak wymiana powietrza czy źródło zasilania obiegów basenowych na jakość wody. W ramach pracy określono, że zanieczyszczenia obecne w wodzie basenowej powoduje jej toksyczność wobec bakterii. Uzyskano niższe wartości toksyczności w przypadku kąpielisk sezonowych, niż w przypadku pływalni krytej. Natomiast nie stwierdzono zależności pomiędzy wysokimi wartościami absorbancji w nadfiolecie UV254 a podwyższoną toksycznością próbek wody. Przeprowadzona ocena toksykologiczna może stanowić przesiewowy test jakości wody basenowej. Istotnym jest by przed jego wykonaniem poddać kontroli zawartość chloru wolnego, ponieważ wysokie stężenia mogą przyczyniać się do uzyskiwania wartości inhibicji bioluminescencji w zakresie wartości dla wysokiej toksyczności.
The tests were to specify the toxic effect on the basis of Vibrio fischeri luminescence inhibition caused by chemical compounds present in pool water samples. The testing tool was Microtox®. This biotest produces quick results thus making it a comfortable tool for testing water for various toxicants. Furthermore, UV254 absorbance measure was carried out and its value was a proxy parameter for defining participation of precursors to disinfection by-products in the samples. Some of the samples had high UV254 values, one of them was 144 m 1. The Microtox® quality tests of indoor and outdoor swimming pool water presented in the paper proved impact of such factors like air exchange or supply of pool water circulation on water quality. Seasonal bathing waters had lower toxicity values. In the context of the work specifies that impurities in the water cause its toxicity. However, there was no relationship between high UV254 absorbance values and higher toxicity of the samples. The toxicological analysis may serve as a screening test of swimming pool water quality. It is of key importance to check the free chlorine value for a water sample. High chlorine concentration can cause higher bioluminescence inhibition values.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 210-216
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/387996.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
integrated process
washings nanofiltration
coagulation
sedimentation
swimming pool water
Installation
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
Opis:
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5–3.0 mgAl/dm3 and sedimentation where the scope of duration 0.5–24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. DK GE Osmonics membrane was used as a nanofiltration membrane. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mgAl/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after coagulation with dose 3.0 mgAl/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
W pracy przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu koagulacji–sedymentacji–nanofiltracji do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5–3,0 mgAl/dm3) oraz sedymentacji (czas trwania 0,5–24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mgAl/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Obecność cząsteczek osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, w której zastosowano wyższą dawkę koagulantu (3,0 mgAl/dm3), równocześnie spowodowała stopniowy wzrost zdolności separacyjnych membrany – utworzyła się tzw. membrana wtórna charakteryzująca się mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 227-236
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of Large Scale Pool Fire of Technical Ethanol
Badania pożaru powierzchniowego etanolu technicznego w dużej skali
Autorzy:
Tępiński, Jarosław
Klapsa, Wojciech
Cygańczuk, Krzysztof
Lesiak, Piotr
Lewak, Michał Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2060712.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
pool fire
field tests
technical ethanol
temperature
thermal radiation
pożar powierzchniowy
badania poligonowe
etanol techniczny
temperatura
promieniowanie cieplne
Opis:
Aim: The aim of this article is to determine the characteristics of a pool fire, including the temperatures and thermal radiation densities caused by it. Mappings of pool fires occurring in actual emergency events were conducted by performing large-scale polygon tests. Project and methods: Experimental study of pool fire of technical ethanol was carried out on a specially built test stand in the training area of the Training Centre in Pionki of the Regional Headquarters of the State Fire Service in Warsaw. The pool fire test stand consisted of a test tray, with a test chamber with the diameter of 300 cm, founded on a reinforced concrete slab. Using a developed measurement system with data acquisition that included measurement sensors mounted at defined locations relative to the fire, temperatures and thermal radiation densities were measured at various distances/locations relative to the fire. Metrological data such as air temperature, atmospheric pressure, humidity, wind direction and speed were monitored and recorded using the weather station. The height of the fire flame was measured by comparing it to racks set up nearby with marked scales of specific lengths. Results: A polygon stand that was built to study pool fires, equipped with a temperature and thermal radiation density measuring system with measuring sensors distributed in defined locations, is discussed. A study of a pool fire resulting from the combustion of dehydrated, fully contaminated ethanol was conducted. The study measured temperatures, thermal radiation densities, and flame heights. The average and maximum values of temperatures and thermal radiation densities during the steady-state combustion stage (i.e., phase II of the fire) were determined. Conclusions: Based on the presented results of temperature and thermal radiation density measurements at various distances/locations relative to the pool fire site, there was a significant effect of wind direction and speed on these values. Higher temperature and heat radiation density were recorded at the sensors on the leeward side than on the windward side. As the wind speed decreased, there was an increase in the temperature values recorded on the thermocouples located above the centre of the bottom of the tray test chamber due to the flame, which, when not blown away, was allowed to rise vertically upward and fully sweep the temperature sensors.
Cel: Celem artykułu jest określenie charakterystyki pożaru powierzchniowego, w tym temperatur i gęstości promieniowań cieplnych przez niego wywoływanych. Odwzorowania pożarów powierzchniowych mających miejsce w rzeczywistych zdarzeniach awaryjnych przeprowadzono poprzez wykonanie poligonowych badań w dużej skali. Projekt i metody: Badanie doświadczalne pożaru powierzchniowego etanolu technicznego zrealizowano na specjalnie do tego celu zbudowanym stanowisku badawczym na terenie poligonu Ośrodka Szkolenia w Pionkach Komendy Wojewódzkiej Państwowej Straży Pożarnej w Warszawie. W skład stanowiska do badania pożarów powierzchniowych wchodziła taca badawcza, o średnicy komory badawczej wynoszącej 300 cm, posadowiona na płycie żelbetowej. Przy pomocy opracowanego układu pomiarowego z akwizycją danych, w skład którego wchodziły czujniki pomiarowe zamontowane w zdefiniowanych lokalizacjach względem pożaru, dokonano pomiarów temperatur i gęstości promieniowań cieplnych w różnych odległościach/lokalizacjach względem miejsca pożaru. Za pomocą stacji pogodowej monitorowano i rejestrowano dane metrologiczne, takie jak temperatura powietrza, ciśnienie atmosferyczne, wilgotność, kierunek i prędkość wiatru. Pomiaru wysokości płomienia pożaru dokonano przez jego porównanie z ustawionymi w pobliżu stojakami z zaznaczonymi podziałkami o określonych długościach. Wyniki: Omówiono poligonowe stanowisko, które zostało zbudowane do badania pożarów powierzchniowych, wyposażone w układ pomiarowy temperatur i gęstości promieniowań cieplnych z czujnikami pomiarowymi rozmieszczonymi w zdefiniowanych lokalizacjach. Przeprowadzono badania pożaru powierzchniowego powstałego w wyniku spalania etanolu odwodnionego, całkowicie skażonego. W ramach badań dokonano pomiarów temperatur, gęstości promieniowań cieplnych oraz wysokości płomienia. Wyznaczono średnie i maksymalne wartości temperatur i gęstości promieniowań cieplnych w etapie ustalonego spalania (tzn. II faza pożaru). Wnioski: Na podstawie przedstawionych wyników pomiarów temperatur i gęstości promieniowań cieplnych w różnych odległościach/lokalizacjach względem miejsca pożaru powierzchniowego, odnotowano znaczący wpływ kierunku i prędkości wiatru na te wartości. Wyższą temperaturę i gęstość promieniowań cieplnych rejestrowano na czujnikach po stronie zawietrznej niż po stronie nawietrznej. Na skutek spadku prędkości wiatru następował wzrost wartości temperatur rejestrowanych na termoparach umieszczonych nad środkiem dna komory badawczej tacy, co było spowodowane przez płomień, który niezdmuchiwany, mógł unosić się pionowo do góry i w pełni omiatać czujniki temperatury.
Źródło:
Safety and Fire Technology; 2022, 59, 1; 96--109
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości bakteriologicznej i fizyczno-chemicznej wody basenowej w wybranym krytym obiekcie rekreacyjnym
Assessing bacteriological and physicochemical quality of swimming pool water in an indoor recreational object
Autorzy:
Szczygłowska, R.
Chyc, M.
Burzała, B.
Kołwzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/236846.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
kryty basen
jakość wody
dezynfekcja
Pseudomonas aeruginosa
mętność
potencjał redoks
turbidity
swimming pool
water quality
disinfection
redox potential
Opis:
Jakość wody w krytych obiektach rekreacyjnych (pływalnie, SPA, parki wodne) ma bardzo istotne znaczenie zdrowotne. Niewłaściwie prowadzony proces dezynfekcji wody basenowej może powodować zakażenia bakteriologiczne, przy czym stosowanie środków dezynfekcyjnych w nadmiernych ilościach może również powodować schorzenia u ludzi. W pracy dokonano oceny jakości wody w wybranej pływalni na podstawie rutynowej oraz rozszerzonej analizy mikrobiologicznej i fizyczno-chemicznej. Wykazano, że rutynowa analiza mikrobiologiczna wody basenowej nie pozwala na prawidłową ocenę jej stanu sanitarnego. Rutynowe wskaźniki mikrobiologiczne osiągnęły bowiem poziom potwierdzający zadowalającą jakość wody w odniesieniu do prawie wszystkich punktów pomiarowych badanego obiektu. Wyjątek stanowiły wanny SPA oraz brodzik dla dzieci, gdzie odnotowano jedynie ponadnormatywną liczbę bakterii mezofilnych (115÷1000 jtk/cm3). Jednak dopiero rozszerzona analiza mikrobiologiczna wody pozwoliła na wykrycie obecności bakterii z rodzaju Pseudomonas, w tym Pseudomonas aeruginosa. Badane próbki wody charakteryzowały się także niższą wartością potencjału redoks (507÷582 mV) oraz mniejszą zawartością chloru wolnego (0÷0,1 gCl2/m3). Jedną z przyczyn okresowego pojawiania się bakterii Pseudomonas był zastój wody w elementach instalacji, w których następował rozwój tych bakterii w ilościach przekraczających 100 jtk/cm3, a także gronkowców koagulazododatnich. Bakterie z rodzaju Pseudomonas obecne były również w próbkach wody pochodzących z urządzeń do jej rozdeszczania. Otrzymane wyniki wykazały możliwość zasiedlania urządzeń basenowych - w przypadku niewłaściwie prowadzonego procesu dezynfekcji - przez mikroorganizmy stanowiące zagrożenie dla zdrowia użytkowników obiektów rekreacyjnych.
Water quality in indoor recreational objects (swimming pool, SPA, aquapark) is of paramount importance to the health of the users. Inadequate disinfection of swimming pool water may be the underlying cause of various diseases or afflictions. In the recreational object chosen for the study reported on here, water quality assessments were carried out using routine and extended microbiological and physicochemical analyses. It has been demonstrated that routine microbiological analysis failed to reliably assess the sanitary condition of the swimming pool water. In terms of routine microbiological indicators, water quality was satisfactory at all sampling sites but two. The two exceptions were in the SPA tubs and wading pools, where mesophilic bacteria alone were found to occur in excessive numbers (115 to 1000 cfu/cm3). Only with extended microbiological analysis was it possible to detect the occurrence of bacteria of the Pseudomonas genus, including Pseudomonas aeruginosa. The water samples examined in this mode also displayed lower redox potential values (507 to 582 mV) and a lower free chlorine content (0 to 0.1 gCl2/m3). The periodical occurrence of Pseudomonas bacteria should, inter alia, be attributed to the stagnation of water in some parts of the installation, where their growth rate was found to exceed 100 cfu/cm3, and where the presence of coagulase-positive staphylococci was detected. Pseudomonas bacteria were also present in the water samples collected from spray irrigators and rain showers. The results obtained make it clear that if the disinfection process is conducted without sufficient efficacy, the microorganisms growing in the swimming pool develop the potential for colonizing the installations, and thus pose health hazards to the swimmer.
Źródło:
Ochrona Środowiska; 2012, 34, 4; 51-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Evaluation of the recycling possibility of washings from swimming poool water treatment system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/126852.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
swimming pool water
back washing water
toxicological assessment
physicochemical analysis
Opis:
Przedstawiono ocenę fizykochemiczną oraz toksykologiczną próbek popłuczyn surowych (pobranych bezpośrednio po procesie płukania złóż filtracyjnych) po procesie napowietrzania oraz procesie dechloracji. Popłuczyny pobrano z obiegów basenowych dwóch krytych pływalni. Przeprowadzono badania wstępne i zasadnicze, w których popłuczyny charakteryzowały się zróżnicowanymi parametrami fizykochemicznymi. Do oceny toksykologicznej zastosowano test inhibicji bioluminescencji Mictorox®, test przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania wstępne obejmowały charakterystykę ekotoksykologiczną popłuczyn poddanych procesom napowietrzania oraz dechloracji. W badaniach zasadniczych analizowano wpływ czasu napowietrzania na jakość popłuczyn. Wyniki badań wstępnych wskazywały, że popłuczyny surowe, jak również po 30-minutowym napowietrzaniu nie mogły być bezpośrednio odprowadzone do środowiska naturalnego ze względu na wysoką toksyczność w stosunku do organizmów żywych. Zastosowanie dłuższego czasu napowietrzania (160 minut) przyczyniło się do znacznej poprawy jakości popłuczyn i eliminacji ich właściwości toksycznych w stosunku do organizmów wskaźnikowych. Zróżnicowane efekty uzyskano po procesie chemicznej dechloracji. Odnotowano stymulację bioluminescencji bakterii (testu Microtox®), ale równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem popłuczyn. Ze względu na zmienność jakości popłuczyn, obecność w nich ubocznych produktów dezynfekcji i koagulacji oraz toksyczne oddziaływanie na organizmy niezbędne jest rozszerzenie badań w zakresie metod umożliwiających ich recykling.
This study discusses the physical and chemical analysis as well as toxicological evaluation of backwashings samples collected after rising raw filter beds, following aeration and dechlorination process. The tested washings were collected at facilities located in two indoor swimming pools. Toxicological evaluation included Mictorox® bioluminescence inhibition assay, Chaoborus sp. larvae survivability test as well as Lemna minor duckweed fito test. The initial stage of the research was focused on eco-toxicological properties of backwashings, subject to aeration and dechlorination processes. The main stage of the research involved additional analysis of the impact of aeration duration on the quality of washings in terms of physical and chemical parameters. The results of the initial stage clearly suggest that both raw washings as well as washings after 30 minutes of aeration are not suitable for direct disposal in the environment due to biohazards resulting from high toxicity of washings. On the other hand extension of the aeration process (160 minutes) contributed to significant improvement of washings quality and removal of toxic properties in relation to the indicator species used in the research. Chemical dechlorination ended with varying results. Microtox® bioluminescence assay resulted in bacteria bioluminescence with simultaneous observation of death of individual larvae. Despite high increase of biomass in Lemna minor test, some gradual decolouration of shoots as the result of washings used. In further solutions for recycling must be sought which will provide reduced water consumption and sewage.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 185-193
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena cieplno-wilgotnościowa stropodachu szczelinowego nad basenem na przykładzie rozwiązania zrealizowanego w praktyce
Evaluation of the thermal and damp properties of a slotted flat roof over a swimming pool, based on a practical example
Autorzy:
Byrdy, A.
Kisilewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/163551.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
stropodach szczelinowy
właściwości cieplno-wilgotnościowe
przykład
swimming pool
slotted flat roof
thermal and moisture control properties
example
Opis:
Hale krytych basenów są obiektami, w których panuje wysoka temperatura i wilgotność względna powietrza wewnętrznego. Takie warunki stawiają wysokie wymagania przy projektowaniu przegród zewnętrznych tego rodzaju obiektów, ze szczególnym uwzględnieniem stropodachów. W artykule przeanalizowano błędy projektowe w przykładowym zrealizowanym stropodachu, który wykazał problemy eksploatacyjne już w pierwszych miesiącach funkcjonowania obiektu.
Indoor swimming pool buildings are subject to high temperatures and relative humidity of the air in their interior. These conditions entail stringent requirements for the design of the external partitions of such buildings, particularly their flat roofs. This article contains an analysis of design errors based on the example of a roof which suffered operational problems only months after the facility was opened.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 2, 2; 47-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan zachowania i sposoby renowacji żelbetowych niecek basenowych
The condition and manners of the renovation of reinforced concrete swimming-pools
Autorzy:
Pająk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/162027.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
pływalnia
konstrukcja żelbetowa
stan techniczny
korozja zbrojenia
renowacja
swimming pool
reinforced concrete structures
technical state
reinforcement corrosion
renovation method
Opis:
Żelbetowe niecki basenowe otwartych i krytych pływalni narażone są na oddziaływania agresywnych środowisk atmosferycznych, gruntowych oraz wodnych powodujących korozję betonu i zbrojenia. W artykule na kilku przykładach żelbetowych niecek, zrealizowanych w latach 70. XX w., przedstawiono stan zachowania konstrukcji. Opisano najczęściej występujące uszkodzenia i ich wpływ na nośność i bezpieczeństwo konstrukcji. Przedstawiono stosowane sposoby renowacji i wzmocnień uszkodzonych niecek basenowych.
Reinforced concrete structures of swimming-pools are exposed to influences of aggressive atmospheric environment, soil environment and water environment, causing the corrosion of concrete and reinforcement. A few examples of reinforced concrete swimming-pools, build in 70 years the 20th century, the condition of the structure was presented. Most often appearing damage and their influence on the carrying capacity and the safety of the structure were described. Applied manners of the renovation and construction strengthening were presented.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 6, 6; 63-66
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zawartość chloru w różnych punktach niecki basenowej - analiza ryzyka dla zdrowia kąpiących się
Chlorine contamination in different points of pool - risk analysis for bathers’ health
Autorzy:
Wyczarska-Kokot, J.
Lempart, A.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127220.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mapa chloru
system hydrauliczny basenu
zagrożenie zdrowia kąpiących się
map of chlorine
pool hydraulic system
risk to bathers’ health
Opis:
Stacja oczyszczania i dezynfekcji wody basenowej spełnia swoje zadanie pod warunkiem współpracy systemu hydraulicznego z odpowiednią geometrią niecki basenowej. Przepływ wody przez nieckę basenu może powodować powstawanie „martwych” stref niebiorących udziału w cyrkulacji. W strefach tych różny może być stopień wymieszania dezynfektanta z wodą. Tym samym różna może być skuteczność dezaktywacji mikroorganizmów i wpływ na zdrowie osób kąpiących się. Przedstawiono wyniki fizyczno-chemicznych badań próbek wody basenowej pobranych z charakterystycznych punktów niecki. Szczególną uwagę zwrócono na zawartość chloru wolnego i chloru związanego. Badania przeprowadzono w dwóch krytych basenach różniących się systemem przepływu wody. Na podstawie wyników analiz sporządzono mapy chloru dla niecek basenowych. Wykazano, że dla oceny ryzyka zagrożenia zdrowia osób kąpiących się próbki wody powinny być pobierane z punktów niecki basenowej uznanych za reprezentatywne.
The pool water treatment and disinfection plant fulfills its task, if the hydraulic system cooperates with the appropriate pool basin geometry. Water flow through the pool can cause “dead” zones not involved in circulation. In these zones the degree of mixing the disinfectant with water can be different. In consequence, the effectiveness of microorganisms’ deactivation and the health effects of bathers may be different. The physicochemical results of pool water samples taken from the characteristic points of the basin were presented. Attention has been paid to the content of free chlorine and combined chlorine. The study was conducted in two indoor pools, differing in water flow. Based on the analysis results, chlorine maps for swimming pools were prepared. It has been shown that in order to assess the health risk to bathers samples of water should be collected from representative points of pool.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 275-283
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
UV filters as disinfection by-products precursors in swimming pool water
Filtry UV jako prekursory tworzenia ubocznych produktów chlorowania wody basenowej
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Nowak-Bator, M.
Powiązania:
https://bibliotekanauki.pl/articles/127505.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
disinfection by-products
personal care products
UV filters
swimming pool water
uboczne produkty dezynfekcji
kosmetyki
filtry UV
woda basenowa
Opis:
The disinfection by-products formation precursors, which are brought into swimming water with swimmers, are not only the human body fluids released during the workout, but also hair, epidermis and residues of personal care products. The cosmetics contain the whole range of substances, however UV filters have the special importance in a case of swimming water. The article presents the results of experiments on the disinfection by-products formation potential of model solutions of UV filters: ethylhexyl methoxycinnamate (EHMC); butyl methoxydibenzoylmethane (BM-DBM); 4-methylbenzylidene camphor (4-MBC); octocrylene (OC); benzophenone-3 (BP3); ethylhexyl salicylate (EHS), octyl dimethyl-para-amino-benzoic acid (OD-PABA). These substances belong to different groups of cosmetics commonly used to protect skin against solar radiation. In the presented research the following by-products were analyzed: trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane, tribromomethane), haloacetic acids (monochloroacetic acid, dichloroacetic acid, bromochloroacetic acid, dibromoacetic acid, trichloroacetic acid), haloacetonitriles (bromochloroacetonitrile, dibromoacetonitrile, dichloroacetonitrile, trichloroacetonitrile), haloketones (1,1-dichloro-2-propanone, 1,1,1-trichloro-2-propanone), chloropicrin and chloral hydrate. For the experiments, the test of by-products formation potential in swimming water was applied, with 24 h time of swimming water samples incubation. The results were used to define which UV filters have the highest potential to form halogenated organic by-products of water chlorination.
Wprowadzane z osobami kąpiącymi się do wody basenowej prekursory tworzenia produktów ubocznych dezynfekcji to nie tylko wydzieliny ciała uwalniane podczas wysiłku, ale także włosy, naskórek oraz zanieczyszczenia, znajdujące się na powierzchni skóry, pochodzące ze środków do pielęgnacji ciała. Składniki kosmetyków to cała gama związków, jednak filtry UV w przypadku wody basenowej mają szczególne znaczenie. W artykule przedstawiono wyniki badań nad potencjałem tworzenia się szeregu organicznych produktów ubocznych chlorowania modelowych roztworów zawierających filtry UV: 4-metoksycynamonian 2-etyloheksylu (EHMC); 1-(4-tert-butylofenylo)-3-(4-metoksyfenylo)propano-1,3-don (BM-DBM); 3-(4-metylobenzylideno)-d-1 kamfora (4-MBC); ester 2-etyloheksylowy kwasu 2-cyjano-3,3-difenyloakrylowego (OC); 2-hydroksy-4metoksybenzofenon (BP3); ester 2-etyloheksylowy kwasu salicylowego (EHS), ester 2-etyloheksylowy kwasu 4-dimetyloaminobenzoesowego (OD-PABA). Związki te należą do różnych grup związków powszechnie używanych do ochrony skóry przed promieniowaniem słonecznym. W badaniach przeanalizowano potencjał tworzenia się następujących produktów ubocznych: trihalometanów (trichlorometan, bromodichlorometan, dibromochlorometan, tribromometan), kwasów halogenooctowych (kwas monochlorooctowy, kwas dichlorooctowy, kwas trichlorooctowy, kwas bromochlorooctowy i kwas dibromooctowy), haloacetonitryli (trichloroacetonitryl, dichloroacetonitryl, bromochloroacetonitryl, dibromoacetonitryl), haloketonów (1,1-dichloroproponon, 1,1,1-trichloropropanon) oraz wodzianu chloralu i chloropikryny. Badania prowadzono z wykorzystaniem testu na potencjał tworzenia się produktów ubocznych w wodzie basenowej, stosując 24 h czas inkubacji próbek wody basenowej. Analiza otrzymanych wyników pozwoliła ocenić, które związki z grupy filtrów UV mają najwyższe powinowactwo do tworzenia się halogenowych organicznych produktów chlorowania wody.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 577-584
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chlorine contamination in different points of pool – risk analysis for bathers’ health
Zawartość chloru w różnych punktach niecki basenowej – analiza ryzyka dla zdrowia kąpiących się
Autorzy:
Wyczarska-Kokot, J.
Lempart, A.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388266.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
map of chlorine
pool hydraulic system
risk to bathers’ health
mapa chloru
system hydrauliczny basenu
zagrożenie zdrowia kąpiących się
Opis:
The pool water treatment and disinfection plant fulfills its task only if the hydraulic system cooperates with the appropriate pool basin geometry. Water flow through the pool can cause “dead” zones not involved in circulation. In these zones the degree of mixing the disinfectant with water can be different. In consequence, the effectiveness of microorganisms’ deactivation and the health effects on bathers may be different. The physicochemical results of pool water samples taken from the characteristic points of the basin were presented. Attention has been paid to the content of free chlorine and combined chlorine. The study was conducted in two indoor pools, differing in water flow system. Based on the analysis results, chlorine maps for swimming pools were prepared. It has been shown that in order to assess the health risk to bathers samples of water should be collected from representative points of the pool.
Stacja oczyszczania i dezynfekcji wody basenowej spełnia swoje zadanie pod warunkiem współpracy systemu hydraulicznego z odpowiednią geometrią niecki basenowej. Przepływ wody przez nieckę basenu może powodować powstawanie „martwych” stref niebiorących udziału w cyrkulacji. W strefach tych różny może być stopień wymieszania dezynfektanta z wodą. Tym samym różna może być skuteczność dezaktywacji mikroorganizmów i wpływ na zdrowie osób kąpiących się. Przedstawiono wyniki fizyczno-chemicznych badań próbek wody basenowej pobranych z charakterystycznych punktów niecki. Szczególną uwagę zwrócono na zawartość chloru wolnego i chloru związanego. Badania przeprowadzono w dwóch krytych basenach różniących się systemem przepływu wody. Na podstawie wyników analiz sporządzono mapy chloru dla niecek basenowych. Wykazano, że do oceny ryzyka zagrożenia zdrowia osób kąpiących się próbki wody powinny być pobierane z punktów niecki basenowej uznanych za reprezentatywne.
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 217-226
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heading control system design for a micro-USV based on an adaptive expert S-PID algorithm
Autorzy:
Miao, R.
Dong, Z.
Wan, L.
Zeng, J.
Powiązania:
https://bibliotekanauki.pl/articles/258606.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
micro unmanned surface vessel (micro-USV)
control system design
adaptive expert S-PID algorithm
heading control
pool experiment
lake experiment
Opis:
The process of heading control system design for a kind of micro-unmanned surface vessel (micro-USV) is addressed in this paper and a novel adaptive expert S-PID algorithm is proposed. First, a motion control system for the micro-USV is designed based on STM32-ARM and the PC monitoring system is developed based on Labwindows/CVI. Second, by combining the expert control technology, S plane and PID control algorithms, an adaptive expert S-PID control algorithm is proposed for heading control of the micro-USV. Third, based on SL micro-USV developed in this paper, a large number of pool experiments and lake experiments are carried out, to verify the effectiveness and reliability of the motion control system designed and the heading control algorithm proposed. A great amount of comparative experiment results shows the superiority of the proposed adaptive expert S-PID algorithm in terms of heading control of the SL micro-USV.
Źródło:
Polish Maritime Research; 2018, 2; 6-13
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identifying the pool-point bar location based on experimental investigation
Określanie lokalizacji odsypiska na podstawie badań eksperymentalnych
Autorzy:
Maatooq, Jaafar S.
Hameed, Luay
Powiązania:
https://bibliotekanauki.pl/articles/293076.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
experimental investigation
meander evolution
morphologic properties
pool-point bar
river sand
badania doświadczalne
cechy morfologiczne
ewolucja meandru
odsypisko
piasek rzeczny
Opis:
Morphological relationships of meander evolution in terms of hydraulic and geometric characteristics are essential for river management. In present study, an experimental based study of meander evolution was employed to develop a prediction formula for identifying the pool-point bar location by using the dimensional analysis technique and multiple nonlinear regressions. Through the experimental work on a race of the non-uniform river sand, a set of experimental runs have been carried out through combining different hydraulic and geometric parameters to produce different empirical conditions that have a direct impact on the pool-point bar location. Based on the experimental observations and measurements, the variation in pool–point bar locations could be interpreted to that the hydraulic and morphologic properties through the meander evolution were varied during the time causes the variations in the patterns of the pool-point bar formations accordingly. The developed formula was verified by using another set of the experimental data and tested with three statistical indicators. The predicted results indicated that the proposed formula had high reliability for practical estimation of the pool-point bar location. This reliability was tested by the statistical indicators, where the less values have been resulted for bias and mean absolute error (MAE), 0.0004 and 0.0110 respectively, whereas the higher values 0.935 and 0.930 are achieved for the Nash–Sutcliffe efficiency (NSE) and the determination coefficient R2, respectively.
Morfologiczne zależności rozwoju meandrów, określane cechami hydraulicznymi i geometrycznymi, są ważne dla gospodarki wodnej. W przedstawionej pracy opisano eksperymentalne badania rozwoju meandrów celem uzyskania prognostycznego wzoru do określenia lokalizacji odsypiska z użyciem techniki analizy wymiarowej i wielorakiej regresji nieliniowej. Przeprowadzono serię eksperymentów nad przemieszczaniem niejednorodnego piasku rzecznego poprzez łączenie różnych parametrów hydraulicznych i geometrycznych, aby osiągnąć różne warunki doświadczalne, które mają wpływ na lokalizację odsypiska. Na podstawie obserwacji i pomiarów z doświadczeń zmienność lokalizacji można interpretować jako zmienność w czasie hydraulicznych i morfologicznych cech tworzenia meandru, które odpowiednio zmieniają położenie odsypiska. Uzyskany wzór weryfikowano, używając innego zestawu danych eksperymentalnych i testowano za pomocą trzech wskaźników statystycznych. Wyniki wskazują, że proponowany wzór ma dużą wiarygodność w praktycznym szacowaniu lokalizacji odsypiska. Wiarygodność tę sprawdzono za pomocą wskaźników statystycznych, w których uzyskano mniejsze wartości dla błędu systematycznego – 0,0004 i średniego błędu bezwzględnego (MAE) – 0,011, podczas gdy wyższe wartości osiągnięto dla współczynnika efektywności Nasha–Sutcliffe’a (NSE) – 0,935 i współczynnika determinacji R2 – 0,930.
Źródło:
Journal of Water and Land Development; 2019, 43; 106-112
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Baseny i kąpieliska geotermalne w Islandii jako element przestrzeni publicznej. Rozwiązania funkcjonalne, przestrzenne i krajobrazowe sprzyjające kontaktom społecznym
Swimming pools and geothermal baths in Iceland as an element of public space. Functional, spatial and landscape solutions conducive to social contacts
Autorzy:
Homiński, B.
Powiązania:
https://bibliotekanauki.pl/articles/345043.pdf
Data publikacji:
2018
Wydawca:
Politechnika Krakowska im. Tadeusza Kościuszki. Wydział Architektury. Katedra Kształtowania Środowiska Mieszkaniowego
Tematy:
basen geotermalny
energia geotermalna
infinity pool
krajobraz
przestrzeń publiczna
Islandia
geothermal bath
geothermal energy
hot tub
landscape
public space
Iceland
Opis:
Baseny kąpielowe i pływackie są powszechnym elementem infrastruktury społecznej wielu miejscowości w Islandii. Pełnią nie tylko funkcję rekreacyjną i sportową. Dzięki swojej powszechności, niskiemu kosztowi dostępu, a także atrakcyjności gorących kąpieli w chłodnym klimacie, otwarte publiczne baseny są rodzajem specyficznych dla Islandii przestrzeni publicznych. Rekompensują one niedostatki tradycyjnie rozumianej przestrzeni miejskiej w miejscowościach i osadach o rozproszonej strukturze. Wykorzystując narzędzia wielokrotnych studiów przypadków, z zastosowaniem technik analizy literatury i rysunku architektonicznego, wizyt w terenie i obserwacji nieuczestniczącej, analizie poddano rozwiązania architektoniczne i krajobrazowe zastosowane w trzech realizacjach otwartych basenów i kąpielisk w Islandii pod kątem przypisywanej im funkcji publicznej, integrującej i społecznej. W wyniku przeprowadzonej analizy ustalono że: nieczęsto program użytkowy basenu bywa uzupełniany funkcjami towarzyszącymi, takimi jak np. kawiarnia; rozwiązania projektowe kąpielisk obejmują niecki i jacuzzi z gorącą wodą o różnej wielkości, kształtach i zorientowaniu względem obiektu; wspólną cechą analizowanych obiektów jest powiązanie widokowe kąpieliska i niecek z gorącymi źródłami z krajobrazem.
Bathing and swimming pools are a common element of social infrastructure of many of Iceland’s localities. Their function is not limited to recreation and sports. Thanks to their spread, low admission costs, as well as the attractiveness of hot baths in the cold climate, open public pools are a type of public spaces that are specific to Iceland. They compensate for the lack of traditionally understood urban spaces in localities and settlements that feature a dispersed structure of low density. Using tools such as the multiple-case study with the application of the techniques of analysing literature and architectural drawings, on-site visits and non-participatory observation, the author analysed the architectural and landscape solutions applied in three built projects featuring open-air pools and bathing facilities in Iceland in terms of their ascribed public, integrating and social function. As a result of the analysis, the author determined that: the functional programme of the pool is not commonly supplemented by accompanying functions, such as, for instance, coffee shops; the design solutions of the bathing facilities include pools and Jacuzzi or hot tubs of varying size, shape and orientation relative to the structure; the common characteristic of the analysed structures was the visual connection of the bathing facilities and the hot tubs with the landscape.
Źródło:
Środowisko Mieszkaniowe; 2018, 24; 130-141
1731-2442
2543-8700
Pojawia się w:
Środowisko Mieszkaniowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydrographic and hydrochemical conditions in the Gotland Deep area between 1992 and 2003
Autorzy:
Nausch, G.
Matthaus, W.
Feistel, R.
Powiązania:
https://bibliotekanauki.pl/articles/48546.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
nutrient pool
temperature
hydrography
hydrochemical condition
ventilation
nutrient distribution
bottom water
salinity
Baltic Sea
stagnation period
hydrographic condition
Gotland Deep
Opis:
The paper describes the hydrographic-hydrochemical development in the eastern Gotland Basin between the major saltwater inflows into the Baltic Sea in 1993 and 2003. This period is characterised by only low inflow activity. The most important hydrographic events were the effects of the very strong inflow in 1993 and the weak inflows in 1993/1994 and 1997. The 1993/1994 inflows led to deep-water renewal, a steep fall in deep-water temperatures, and increasing salinity. The effects of the inflow of very warm, saline and oxygen-rich water in autumn 1997 were observed in the deep water in 1998, resulting in temperatures rising to 7◦C. The recent renewal in spring 2003 is reflected in the decreasing temperature, higher salinity and improved ventilation of the bottom water. Changes in the redox conditions exert a considerable influence on the nutrient distribution. During stagnation periods, there is enrichment of phosphate and ammonium, while nitrate is absent. Thus, around 31 μmol l−1 ammonium and 7 μmol l−1 phosphate were measured prior to the water renewal in 2003. Deepwater ventilation results in lower phosphate concentrations of around 2 μmol l−1, the nitrification of ammonium and the occurrence of nitrate. For the observation period, an estimate of nutrients stored in the deep water was done for the eastern Gotland Basin. During the recent stagnation period, there was an increase of up to 150% in the phosphate pool below the halocline, whereas the pool of inorganic nitrogen compounds decreased to 80% compared with 1992 when the previous stagnation period had ended. Under specific circumstances, these unbalanced nutrients can be made available to the upper water layers and can induce large-scale blooms of algae, especially of cyanobacteria.
Źródło:
Oceanologia; 2003, 45, 4
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Beneficial Ownership in Cash Pooling Arrangements
Autorzy:
Cieślewicz, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/1963184.pdf
Data publikacji:
2020
Wydawca:
Akademia Leona Koźmińskiego w Warszawie
Tematy:
beneficial owner
liquidity management
loan agreement
interest
market value
capital group
pool leader
global agent
OECD
transfer prices
cash pooling
Opis:
Cash pooling is a method of managing financial resources, which works well primarily in enterprises with an extensive corporate structure and operating within capital groups. The choice of a given form of cash pooling will depend on the entrepreneur’s individual preferences. Although using this method has many advantages, it still raises legal doubts. There is a lack of provisions in Poland that would precisely regulate this type of agreement. In many cases, the design of the cash pooling agreement is similar to a loan agreement. However, it is worth paying attention to the basic differences, such as the fact that the essence of cash pooling is not an obligation to transfer a specific monetary value to an entity specified in the contract. These and other specific features of cash pooling agreements mean that it is not always obvious to which entity and on what terms an entity can be granted the status of beneficial owner. An additional, verification obligations imposed on the Polish payer and the need to act with due diligence are practical impediments.
Źródło:
Krytyka Prawa. Niezależne Studia nad Prawem; 2020, 12, 1; 58-75
2080-1084
2450-7938
Pojawia się w:
Krytyka Prawa. Niezależne Studia nad Prawem
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pool boiling of nanofluids on rough and porous coated tubes: experimental and correlation
Autorzy:
Cieśliński, J. T.
Kaczmarczyk, T. Z.
Powiązania:
https://bibliotekanauki.pl/articles/240179.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pool boiling
nanofluids
correlation equation
rough and porous coated tubes
wrzenie w objętości
nanopłyny
równanie korelacyjne
rury z powłoką porowatą
Opis:
The paper deals with pool boiling of water-Al2O3 and water-Cu nanofluids on rough and porous coated horizontal tubes. Commercially available stainless steel tubes having 10 mm outside diameter and 0.6 mm wall thickness were used to fabricate the test heater. The tube surface was roughed with emery paper 360 or polished with abrasive compound. Aluminium porous coatings of 0.15 mm thick with porosity of about 40% were produced by plasma spraying. The experiments were conducted under different absolute operating pressures, i.e., 200, 100, and 10 kPa. Nanoparticles were tested at the concentration of 0.01, 0.1, and 1% by weight. Ultrasonic vibration was used in order to stabilize the dispersion of the nanoparticles. It was observed that independent of operating pressure and roughness of the stainless steel tubes addition of even small amount of nanoparticles augments heat transfer in comparison to boiling of distilled water. Contrary to rough tubes boiling heat transfer coefficient of tested nanofluids on porous coated tubes was lower compared to that for distilled water while boiling on porous coated tubes. A correlation equation for prediction of the average heat transfer coefficient during boiling of nanofluids on smooth, rough and porous coated tubes is proposed. The correlation includes all tested variables in dimensionless form and is valid for low heat flux, i.e., below 100 kW/m2.
Źródło:
Archives of Thermodynamics; 2014, 35, 2; 3-20
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usługi nieruchomościowe w gospodarce krajów Unii Europejskiej
Property services in the economies of EU Member States
Autorzy:
Kałkowski, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/414894.pdf
Data publikacji:
2012-06
Wydawca:
Małopolska Wyższa Szkoła Ekonomiczna w Tarnowie
Tematy:
zasób nieruchomości
przepływy międzygałęziowe
budownictwo
usługi nieruchomościowe
mieszkalnictwo
a pool of properties
input-output analysis
construction industry
property services
housing industry
Opis:
Działalność związana z obsługą światowego zasobu nieruchomości stanowi znaczący dział gospodarki narodowej każdego kraju. Jest ona rejestrowana jako oddzielny wiersz i kolumna w narodowych tablicach przepływów międzygałęziowych. Dzięki Eurostatowi mamy wgląd w anglojęzyczne tablice 26 państw należących do Unii Europejskiej z lat 1995-2007. Analiza tablic przepływów międzygałęziowych 26 krajów UE pozwoliła pogłębić i ugruntować naszą wiedzę o pozycji ekonomicznej działu real estate w gospodarce badanych państw. Pomimo pewnych usterek i luk badanego materiału otrzymano obraz w miarę wiarygodny, pogłębiony i aktualny. Dział real estate jawi się w badanym materiale statystycznym jako znaczący, reprezentujący 5,7% udziału w łącznej wartości produkcji globalnej krajów UE, ustabilizowany w czasie. Kooperuje on ze wszystkimi pozostałymi działami tablicy narodowej. Obsługa nieruchomości systematycznie towarzyszy działowi „budownictwo”, z którym razem stanowi 1/8 produkcji globalnej każdego kraju. Głównym odbiorcą usług nieruchomościowych jest mieszkalnictwo, częściowo także obiekty niemieszkalne. Wskaźnik (umowny) na jedno statystyczne mieszkanie w skali miesięcznej odpowiada aktualnej rzeczywistości i wynosił w 2007 roku (ostatni rok badań) od 105 do 318 euro na osobę. Gospodarka Polski - przy gorszych parametrach kwestii mieszkaniowej - wydatkowała na obsługę całego swojego zasobu nieruchomości kwotę około 260 zł (65 euro) miesięcznie na obywatela, przy podobnej do pozostałych krajów dynamice nakładów.
Services related to the world pool of properties constitute a significant sector of the national economy of each country. It is recorded in a separate row and column of national input-output tables. Thanks to Eurostat, we have access to tables of 26 EU Member States in the English language, presenting figures from years 1995-2007. The analysis of input-output tables of the 26 EU states made us deepen and reinforce our knowledge about the position of the real property sector in the economies of the analysed countries. Despite certain deficiencies and gaps of the studied material, the obtained picture is quite reliable, detailed and up to date. Based on the studied statistical materials, the real property sector seems significant, representing 5.7% share of the total value of the EU states’ total output, and stable in time. It cooperates with all other sectors included in national tables. Property services are usually accompanied by the construction sector. Together they constitute 1/8 of each state’s total output. The main ‘users’ of property services is the housing industry and, to some extent, non-residential buildings. The symbolic indicator per 1 statistical flat per month represents the actual situation, and in 2007 (the last year of the studies) it was equal to 105-318 euro per person. The Polish economy—with worse parameters related to housing—expended around 260 zlotys (65 euro) on services related to its pool of properties, with similar level of capital investment as compared to other states.
Źródło:
Zeszyty Naukowe Małopolskiej Wyższej Szkoły Ekonomicznej w Tarnowie; 2012, 1(20); 63-72
1506-2635
Pojawia się w:
Zeszyty Naukowe Małopolskiej Wyższej Szkoły Ekonomicznej w Tarnowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości stosowania promieniowania nadfioletowego w uzdatnianiu wody basenowej – studium przypadku
Assessment of applicability of UV irradiation in swimming pool water treatment – a case study
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Zając, W.
Powiązania:
https://bibliotekanauki.pl/articles/237754.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
swimming pool water
water treatment
UV irradiation
disinfection by-products
operating costs
woda basenowa
uzdatnianie wody
promieniowanie UV
produkty uboczne dezynfekcji
koszty eksploatacji
Opis:
Influence of UV-chlorination sequence application on swimming pool water quality was investigated. In addition, an analysis of operating costs of such system was conducted. The study was based on a real facility, i.e. the swimming pool of AGH University of Science and Technology in Krakow. In the facility, water disinfection with calcium hypochlorite was carried out, assisted by UV irradiation. Switching the UV lamps temporarily off allowed for comparative studies on the quality of pool water disinfected by pure chlorination and by the UV and chlorination sequence. For these two variants of the swimming pool water disinfection several physico-chemical and microbiological parameters were analyzed, including the disinfection by-products. Cost analysis included the consumption of chemical agents and the UV lamp operation. It was established that the UV technology did not contribute to the expected improvement in the pool water quality in terms of the combined chlorine removal, however it did cause an increase in the concentration of selected organic chlorination by-products. Moreover, application of the UV lamp to the pool water treatment system increased the chlorine demand and, consequently, the consumption of calcium hypochlorite. Combined with the need to exchange lamp fi laments, it raised the operating costs of the pool water treatment technology.
Badano wpływ zastosowania technologii UV w połączeniu z chlorowaniem na jakość wody basenowej, a także przeprowadzono analizę kosztów eksploatacyjnych takiego systemu. Badania przeprowadzono na rzeczywistym obiekcie, jakim jest basen sportowy Akademii Górniczo-Hutniczej w Krakowie. W obiekcie tym dezynfekcja wody jest prowadzona z wykorzystaniem podchlorynu wapnia, a proces ten jest wspomagany naświetlaniem wody promieniami nadfioletowymi (UV). Wyłączenie lamp UV na określony czas pozwoliło na przeprowadzenie badań porównawczych jakości wody basenowej dezynfekowanej tylko chlorem oraz z zastosowaniem układu UV/Cl2. Przeanalizowano szereg wskaźników mikrobiologicznych oraz fizyczno-chemicznych, w tym produktów ubocznych chlorowania, w obu wariantach dezynfekcji wody basenowej. W analizie kosztów uwzględniono zużycie chemikaliów oraz koszty promiennika UV. Stwierdzono, że technologia UV nie spowodowała oczekiwanej poprawy jakości wody basenowej pod względem usuwania chloru związanego, natomiast wpłynęła na zwiększenie ilości niektórych organicznych ubocznych produktów chlorowania. Włączenie lampy UV w system uzdatniania wody basenowej spowodowało również wzrost zapotrzebowania wody na chlor, a w rezultacie większe zużycie podchlorynu wapnia, co w połączeniu z koniecznością wymiany żarników lampy zwiększyło koszty eksploatacyjne technologii uzdatniania wody basenowej.
Źródło:
Ochrona Środowiska; 2017, 39, 1; 53-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instytucjonalna ciągłość i zmiana w społeczności lokalnej. Na przykładzie zarządzania wspólnymi zasobami w Jurgowie, wsi polskiego Spisza
Institutional Continuity and Change in the Local Community. Example of Commons Governing in Jurgów, Village of Polish Spisz
Autorzy:
Chmielewski, Piotr
Chmielewski, Jan
Powiązania:
https://bibliotekanauki.pl/articles/427916.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
instytucjonalni przedsiębiorcy
dylematy społeczne
działanie kolektywne
struktura instytucjonalno-organizacyjna
wspólne zasoby
institutional entrepreneurs
social dilemmas
collective action
institutional-organizational structure
common-pool resources
Opis:
Artykuł analizuje ciągłość i zmianę reguł instytucjonalnych organizujących gospodarowanie wspólnymi leśnymi zasobami społeczności lokalnej Jurgowa, na polskim Spiszu. W wyniku zmiany część zasobów przyrodniczych wykorzystywanych zgodnie z tradycją została przekształcona w ośrodek sportów zimowych. Takie innowacyjne przedsięwzięcie wymagało nowych sposobów zbiorowego działania. Ważną rolę odegrali członkowie wspólnoty występujący w charakterze „okazjonalnych przywódców” i „instytucjonalnych przedsiębiorców”. Mieli oni ułatwione zadanie ze względu na tradycyjnie ugruntowane we wspólnocie sposoby rozwiązywania dylematów społecznych, wysoki poziom kapitału społecznego i zaufania wśród członków wspólnoty oraz spiskie zasoby kulturowe. Artykuł zwraca uwagę na potrzebę badania wspólnych zasobów w Polsce wskazując na fakt, iż ten aspekt różnorodności instytucjonalno-organizacyjnej i społeczno-kulturowej jest szczególnie ważny w obliczu zachodzących zmian. Tekst jest efektem badań jakościowych inspirowanych teoriami nowego instytucjonalizmu, w szczególności „Analizy Instytucjonalnej Rozwoju”.
The article includes analysis of continuity and change of institutional rules applicable to governing the common-pool forest resources in possession of local community of Jurgów village, located within Polish Spisz. As a result of occurring change, traditionally exploited part of environmental resources was repositioned into modern winter sports resort. Such innovative adaptation required, and was challenged, by new collective action that was introduced by local society as common approach. It is such roles of local society members’ representatives, described as ‘occasional leaders’ and ‘institutional entrepreneurs’, that were taking major part in this complex process of transformation. Also noteworthy is that this task was to certain extent simplified by their traditionally rooted within local community resolving of social dilemmas skills, comparably high level of social capital, trust gained over the years among community members and cultural resources of Spisz area. The article directs readers attention towards need of Polish research on common pool resources, indicating that aspects of institutional-organizational structure, as well as, social-cultural diversity is particularly important in face of such changes taking place. This text was also result of qualitative research inspired by new institutionalism theories, in particular ‘Institutional Analysis and Development”.
Źródło:
Studia Socjologiczne; 2017, 3(226); 99-128
0039-3371
Pojawia się w:
Studia Socjologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przydatnośc bakterii grupy Coli jako wskaźnika zanieczyszczenia wody w pływalniach
Prigodnost bakterii gruppy Coli kak pokazatelja zagrjagrjaznenija vody v basseinah dlja v basseinah dlja plavanija
The applicability of the Coli group bacteria as the sanitary indicator of the degree of contamination of water in swimming pools
Autorzy:
Haman, S.
Powiązania:
https://bibliotekanauki.pl/articles/872681.pdf
Data publikacji:
1970
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zanieczyszczenie wod
plywalnie
Escherichia coli
bakterie
badania sanitarne
badania bakteriologiczne
badania naukowe
water pollutant
swimming pool
bacteria
sanitary research
bacteriological examination
scientific research
Źródło:
Roczniki Państwowego Zakładu Higieny; 1970, 21, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational Problems of Selected Elements of the Dobrzyca Barrage on the Głomia River
Problemy eksploatacyjne wybranych elementów stopnia wodnego Dobrzyca na rzece Głomii
Autorzy:
Hämmerling, M.
Walczak, N.
Kałuża, T.
Oliskiewicz-Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813687.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
Dobrzyca barrage
operational problems
impoundment structure
pool fish pass
hydrotechnical structure assessment
stopień wodny Dobrzyca
problemy eksploatacji
budowla piętrząca
przepławka komorowa
ocena konstrukcji hydrotechnicznych
Opis:
A barrage is a type of diversion dam consisting of numerous different structures, demanding high level of maintenance which allow for operating in accordance to water management instructions. The barrage analysed in the present paper is located at 0+640 km of the Głomia river. It includes: a small hydropower plant, a three-gate weir and a technical fish pass (pool fish pass). Location of the barrage, position of its structures in mutual relation, as well as their operation have a practical effect on its specific operational problems. These include i.e.: silting of the reservoir bottom, depositing of plant debris on the weir bars, overgrowing of the river bed. The paper presents a technical condition assessment of these structures and analyses flow rate characteristics of the barrage. With the use of HEC-RAS software the authors tested the effect the topological changes in the water table of the river on the operation of the hydroelectric power station. Besides different possible operational variants of the weir and the power station studied, potential hazards and threats associated with the operation of the barrage are indicated in the paper.
W skład stopnia wodnego wchodzi wiele różnych budowli, których poprawna eksploatacja umożliwia działanie całego stopnia zgodne z instrukcją gospodarowania wodą. Analizowany w pracy stopień zlokalizowany jest na rzece Głomia w km 0+640. W jego skład wchodzą: mała elektrownia wodna, jaz trzy przęsłowy oraz przepławka techniczna (komorowa). Lokalizacja stopnia, wzajemne usytuowanie obiektów i ich eksploatacja wpływają na określone problemy funkcjonowania stopnia wodnego Dobrzyca. Należą do nich, między innymi kłopoty z zamuleniem dna zbiornika, odkładaniem się na kratach rumoszu roślinnego, a także zarastaniem koryta. W pracy przedstawiono ocenę stanu technicznego budowli oraz przeanalizowano warunki przepływu wody przez stopień wodny. Wykorzystując program komputerowy HEC – RAS przebadano wpływ zmian układu zwierciadła wody w korycie rzeki na pracę elektrowni wodnej. Przeanalizowano różne możliwe warianty pracy jazu i elektrowni wodnej. Wskazano możliwe zagrożenia i niebezpieczeństwa związane z pracą stopnia wodnego.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 163-183
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie wody popłucznej z instalacji basenowej w jednostkowym membranowym procesie ultrafiltracji oraz w układzie zintegrowanym napowietrzanie-ultrafiltracja
Treatment of aqueous rinsing liquids of the pool water installation in a unit process of membrane ultrafiltration and in the airing-ultrafiltration integrated system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/270649.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
popłuczyny
woda basenowa
ultrafiltracja
ciśnieniowe procesy membranowe
oczyszczanie strumieni wód odpadowych
washings
pool water
ultrafiltration
pressure driven membrane processes
treatment of streams of wastewater
Opis:
W pracy przedstawiono możliwość wykorzystania membranowego procesu ultrafiltracji do oczyszczania popłuczyn z instalacji basenowych. Badania obejmowały proces jednostkowy ultrafiltracji oraz zintegrowany układ napowietrzanie-ultrafiltracja, który pozwolił na częściowe usunięcie zanieczyszczeń występujących w nadawie. Porównano membrany o zróżnicowanym materiale polimerowym oraz różnej wartości granicznej masy molowej cut-off. Określono wpływ zastosowanego procesu wstępnego na zdolności transportowo-separacyjne membran o różnych własnościach fizyczno-chemicznych. Uzyskano wysoką wydajność hydrauliczną we wszystkich prowadzonych filtracjach (w zakresie od 1,23·10-5 do 1,40·10-7 m³/m²·s). W zakresie usuwania mętności badane układy charakteryzowały się współczynnikiem usunięcia przekraczającym 90%. Odnotowano znaczące usunięcie grupy zanieczyszczeń opisanych przez wskaźnik ogólny, tj. absorbancję w nadfiolecie UV254. Przeprowadzone badania wykazały możliwość wykorzystania ultrafiltracji do odzysku wody basenowej z popłuczyn poprocesowych.
The paper presents the possibility of using the membrane ultrafiltration process for the treatment of washings from pool water systems. The tests included a unit ultrafiltration process and airing-ultrafiltration integrated system which partly removed contamination from the feed material. Membranes of various polymere materials and molar mass cut-off were compared. This helped to determine the influence of the used initial process on transport and separation abilities of the membranes of different physical and chemical features. High hydraulic performance was obtained in all performed filtration actions (1.23·10-5 ÷ 1.40·10-7 m³/m²·s). In respect of fighting turbidity, all tested systems had a removal rate of more than 90%. It was also noted that a significant amount of contamination described by the general indicator, which is specific UV254 absorbance, was removed. The tests proved that ultrafiltration can be used for recovery pool water from post-process washings.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 4; 238-245
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Association between body iron stores and level of oxidatively modified DNA bases
Autorzy:
Dziaman, T.
Jurgowiak, M.
Olinski, R.
Powiązania:
https://bibliotekanauki.pl/articles/80695.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
atherosclerosis
cancer
cardiovascular disease
cellular DNA
free radical damage
heterozygosity
iron deficiency anaemia
labile iron pool
oxidative damage
oxidative stress
reactive oxygen species
vascular disease
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2011, 92, 2
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advances and Perspectives in Using Medical Informatics for Steering Surgical Robots in Welding and Training of Welders Applying Long-Distance Communication Links
Postępy i perspektywy wykorzystania informatyki medycznej do sterowania robotami chirurgicznymi w spawaniu i szkoleniu spawaczy korzystających z połączeń komunikacji na duże odległości
Autorzy:
Prusak, Zbigniew
Tadeusiewicz, Ryszard
Jastrzębski, Ryszard
Jastrzębska, Ilona
Powiązania:
https://bibliotekanauki.pl/articles/115145.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spawanie zdalne
sztuczna inteligencja
rzeczywistość rozszerzona
maska spawalnicza
jeziorko spawalnicze
UHTC
plazma łukowa
remote welding
artificial intelligence
augmented reality
welding mask
weld pool
arc plasma
Opis:
This paper discusses various challenges in remote welding with a surgical robot equipped with a digital camera used to observe the welding zone, in particular the difficulty in detecting the boundaries of the weld pool. The difference in the processing of the real image by the human brain is discussed in comparison with the image in the form of a film from a digital camera. In addition to the need of performing the second derivative of the image in real-time, three models of human recognition of an image were discussed, one of which was already studied by researchers from Cambridge, UK. The concept of melting the base material by bending the weld pool with the pressure of non-ionized arc gases and the American implementation of the measurement of the third dimension of the weld pool and determining the weld penetration by electronics of the welding machine are discussed. Desired movement trajectories of the electrode tip based on the physics of the welding arc and welding technology are presented along with difficulties in teaching the movements to welding trainees. Basics of the neural model of the brain with the vector model of artificial intelligence are also presented.
W artykule omówiono różne wyzwania związane ze spawaniem zdalnym za pomocą robota chirurgicznego wyposażonego w kamerę cyfrową do obserwacji strefy spawania, w szczególności dyskutowano trudność w wykrywaniu granic jeziorka spawalniczego. Omówiono różnicę w przetwarzaniu obrazu rzeczywistego przez ludzki mózg w porównaniu z obrazem w postaci filmu z aparatu cyfrowego. Oprócz potrzeby wykonania drugiej pochodnej obrazu w czasie rzeczywistym, omówiono trzy modele rozpoznawania obrazu przez człowieka, z których jeden był już badany przez naukowców z Cambridge w Wielkiej Brytanii. Omówiono koncepcję topienia materiału podstawowego przez zaginanie jeziorka spawalniczego ciśnieniem niejonizowanych gazów łukowych oraz amerykańską implementację pomiaru trzeciego wymiaru jeziorka spawalniczego i określania wtopienia stymulowanego przez elektronikę spawarki. Przedstawiono pożądane trajektorie ruchu końcówki elektrody w oparciu o fizykę łuku spawalniczego i technologię spawania oraz trudności w uczeniu ruchów praktykantów. Przedstawiono również podstawy neuronowego modelu mózgu wraz z modelem wektorowym sztucznej inteligencji.
Źródło:
Welding Technology Review; 2020, 92, 5; 37-49
0033-2364
2449-7959
Pojawia się w:
Welding Technology Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utility of two mitochondrial markers for identification of Picea abies refugial origin
Autorzy:
Litkowiec, M
Dering, M.
Lewandowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/41333.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Dendrologii PAN
Tematy:
coniferous plant
tree
Norway spruce
Picea abies
mtDNA
molecular marker
mitochondrial marker
identification
polymerase chain reaction
RFLP analysis
gene pool conservation
forest ecosystem
plant population
Opis:
Picea abies (L.) Karst is one of the most important coniferous species of Europe from both ecological and economical points of view. Traditional methods for the gene pool conservation and biodiversity maintenance in forest ecosystems have been practiced in many countries. For progress in this field using highly polymorphic genetic molecular markers is needed. Our goal was to demonstrate the utility of two polymorphic mitochondrial markers mt15-D02 and nad1 b/c in identification native Norway spruce stands. This molecular markers were tested in 1401 individuals from 59 Polish Norway spruce populations. We detected three alleles, which are called1, 2 and3, for locus mt15-D02 and two alleles , which are called1 and2, for locus nad1 b/c in our material. All five variants of alleles indicate the natural origin of P. abies. Result of this study shows that molecular marker mt15-D02 is easy to use and more informative in compare to marker nad1 b/c.
Źródło:
Dendrobiology; 2009, 61; 65-71
1641-1307
Pojawia się w:
Dendrobiology
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies