Tytuł:
Perceived indoor air quality, air-related symptoms and ventilation in Finnish hospitals
Autorzy:
Hellgren, Ulla-Maija
Hyvärinen, Markku
Holopainen, Rauno
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2185474.pdf
Data publikacji:
2011-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
evaluation of ventilation
Indoor Air Questionnaire
perceived indoor air quality
Health care workers
Opis:
Objectives: Good ventilation is more important in hospitals than in many other buildings. The objective of this study was to evaluate the effect of the condition, performance and modernity of ventilation systems on the perceived indoor air quality (IAQ) and the indoor air-related symptoms of hospital personnel. Materials and Methods: An inspection and evaluation graded on a 1 to 3 scale of the condition, performance, and modernity of the ventilation systems was carried out in ten central hospitals in Finland. The perceived IAQ and the related symptoms were collected by means of an indoor air questionnaire survey among the workers in these hospitals. Results: The condition, performance and modernity of the ventilation systems were good in 40% of the hospitals included in the research and poor in another 40% of them. In hospitals where the majority of the ventilation systems were assessed to be good, the prevalence of the indoor air-related complaints and symptoms was lower than in hospitals where the majority of the ventilation systems were assessed as needing extensive repairs. Conclusions: The condition and performance of the ventilation systems in hospitals had a significant impact on the perceived IAQ and the symptoms observed among the employees in Finnish hospitals. Therefore, it is important that hospital ventilation systems are maintained properly and regularly. Furthermore, they should be renovated, at the latest when their technical lifespan expires.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 1; 48-56
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenia ozonu w pomieszczeniach przeznaczonych na czasowy pobyt ludzi
Ozone concentrations in Lublin non-occupational environments
Autorzy:
Staszowska, A.
Dudzińska, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/127306.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ozon
powietrze wewnętrzne
jakość powietrza wewnętrznego
ozone
indoor air
indoor air quality
non-occupational environments
Opis:
Badania przeprowadzono w pomieszczeniach przeznaczonych na czasowy pobyt ludzi: w pokojach biurowych i punktach kserograficznych zlokalizowanych na terenie miasta Lublina. Badania stężenia ozonu w powietrzu wewnętrznym przeprowadzone zostały w dwóch okresach: w okresie letnim i w sezonie grzewczym. Próbki do badań pobierano metodą pasywną. Pomiaru stężenia ozonu dokonano metodą spektrofotometryczną. Stężenia ozonu dla okresu letniego wyniosły: 0,01 -K),04 mg/m3 dla pomieszczeń biurowych oraz 0,008+0,176 mg/m3 dla punktów kserograficznych. Natomiast w sezonie grzewczym stężenia ozonu kształtowały się w następujących przedziałach: 0,007+0,018 mg/m3 dla pomieszczeń biurowych i 0,001-K),015 mg/m3 dla punktów kserograficznych. W punktach kserograficznych dopuszczalne stężenie 0,15 mg/m3 zostało przekroczone w sezonie letnim w dwóch przypadkach. W sezonie grzewczym nie odnotowano przekroczenia dopuszczalnego stężenia w punktach kserograficznych. W przypadku pomieszczeń biurowych dopuszczalne stężenie wynoszące 0,15 mg/m3 nie zostało przekroczone.
Ozone is the common component of indoor air. Because of its high reactivity it plays an important role in forming of indoor air quality, which influence directly on health of interior occupants. It is a well-known fact, that ozone can damage the respiratory system, inflames and irritates respiratory tissues, and can worsen asthmatic symptoms in individuals with asthma. Ozone exposure can produce symptoms such as coughing, chest tightness and impaired breathing. Elevated exposures have the potential to induce permanent lung damage, and even increase the risk of premature death in persons with poor health. Hence, there is a need to measure the concentrations of ozone in indoor air environments. The indoor ozone concentration depends on the outdoor ozone concentrations, the rate at which indoor air is exchanged with outdoor air, interior air circulation, indoor sources of ozone (eg ozone generators, electrostatic air cleaners, photocopiers, and laser printers), the rate at which ozone is removed by indoor surfaces, and reactions between ozone and other chemicals in the air. The objective of this study was to examine ozone concentrations in indoor air in selected non-occupational environments: office rooms and Xerox service points. Summer time and cold (heating) season was examined. Samples were collected using passive method. The ozone concentration on summer time was within the range of 0.04-K).01 mg/m3 for office rooms and 0.008-0.176 mg/m3 for Xerox points. In two examined Xerox places the permitted level of ozone (0.15 mg/m3) was exceeded in summer time. In cold time the permitted level of ozone was not exceeded in any Xerox points. hi offices rooms the permitted level of ozone was not achieved.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 623-627
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Filtration and Sterilization in Ventilation Systems According to the New Paradigm
Autorzy:
Cepiński, Wojciech
Szałański, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2202141.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pathogen
filtration
ventilation
indoor air pollution
indoor air quality
COVID-19
SARS-CoV-2
air handling unit
Opis:
The paper deals with the subject of increasing the efficiency of air purification in ventilation systems in situations of unusual hazardous indoor air pollutants. It analyzes possible locations of additional filtering and sterilizing elements in the installation to eliminate their return to the rooms. The quantities of pollutants in particular parts of the system were determined for a given fan configuration in the air handling unit and a possible leakage in the heat recovery system. Guidelines were proposed for the design and construction of systems to enable rapid modification of systems in the event of unusual contamination or pathogens in the indoor air.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 25--34
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroorganizmy w kurzu z pomieszczeń na przykładzie miasta Lublina
Characterization of the microbial community in settled dust samples from indoor environments in Lublin
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126364.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikroorganizmy
powietrze wewnętrzne
kurz domowy
jakość powietrza wewnętrznego
microorganisms
indoor air
house dust
indoor air quality
Opis:
W pracy jest przedstawiona charakterystyka mikrobiologiczna próbek kurzu zebranych w pomieszczeniach mieszkalnych i placówkach edukacyjnych zlokalizowanych na obszarze miasta Lublina. W kurzu najczęściej spotykanymi bakteriami były pałeczki Gram-dodatnie. Większość należała do rodzaju Bacillus. W próbkach kurzu z placówek edukacyjnych największą koncentrację bakterii stanowił gatunek Bacillus subtillis. Największą grupę po pałeczkach Gram-dodatnich spotykanych w kurzu były ziarniaki Gram-dodatnie. Głównie był to rodzaj Micrococcus, a dominującym gatunkiem był Micrococcus luteus. W kurzu znajdywały się także Gram-dodatnie ziarniaki z rodzaju Staphylococcus oraz Gram-ujemne pałeczki. W przypadku grzybów zawartych w kurzu dominującymi rodzajami były Aspergillus (głównie gatunek Aspergillus nigerii) oraz Penicillium. Grzyb z rodzaju Cladosporium był także spotykany w badanych próbkach.
Dust particles collected from indoor environments may contain hundreds of chemically and biologically active components, which can cause many adverse health effects and deterioration of building materials. While all types of microorganisms can cause problems indoors, bacteria and fungi are most commonly associated with indoor air quality complaints. Some of them produce mucus and excrete chemicals which can provoke allergy, respiratory system and skin irritation, headache, or fatigue. This study was designed to obtain information about characterization of the microbial community in settled dust samples from indoor environments of the Lublin area. Dust samples were collected from households and educational establishments. Microbial species and their concentrations were determined by culture analysis. The concentrations and proportions of morphologically distinguishable culturable bacteria and fungi in dust samples was as follows. In case of bacteria the most commonly found were Gram-positive rods, predominantly Bacillus spp. (Bacillus subtillis) and cocci - genus Micrococcus (Micrococcus leutus) and Staphylococcus. Fungi were represented by genus Aspergillus (mainly Aspergillus nigerii), Penicillium, and Cladosporium. Additionally, microbial concentrations of similar environments vary between sample types, eg total amount of fungi has been higher in dust from textile covered floor than in samples from bare floor.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 325-328
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor air studies of fungi contamination in two kindergartens in Kavala, Greece
Autorzy:
Łukaszuk, C.
Krajewska-Kułak, E.
Chatzopulu, A.
Theodosopoulou, E.
Powiązania:
https://bibliotekanauki.pl/articles/1917817.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Indoor air fungi
kindergartens
SAS Super 100
Opis:
Introduction: Fungi and moulds are biological hazards that are ubiquitous both in the communal and occupational environments. The aim of the study was to assess the presence of airborne fungi in two kindergartens in Kavala, Greece. Materials and methods: Materials for the tests were: the air samples (in front of the buildings and the selected rooms) of the two kindergartens. The first Kavala kindergarten was located atop a hill and the second in the city center. The air pollution was determined using SAS SUPER 100. Results: The mean number of fungal colonies isolated from air of the kindergarten rooms in the city center was 478.3±148.4 CFU/m3. The mean number of fungal colonies isolated from air of the kindergarten on the hill was 343.6±188.8 CFU/m3. Aspergillus niger was most frequently isolated in air samples from the kindergarten rooms in the city center, while Penicillium species predominated the kindergarten rooms on the hill. CFU values in the air samples outside the kindergartens were higher in the center than on the hill of Kavala. CFU values of the examined air samples are varied. In the kindergarten rooms in the center of Kavala the most frequently isolated species was Aspergillus niger, and in the kindergarten on the hill it was Penicillium species. Conclusions: The present study demonstrated considerable numbers of fungi in the air in two kindergartens in Kavala, Greece.
Źródło:
Progress in Health Sciences; 2016, 6(1); 123-129
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of risk perception connected with exposure to indoor air pollution in the group of inhabitants of Silesian Voivodeship
Ocena percepcji zagrożeń związanych z narażeniem na zanieczyszczenie powietrza wnętrz w grupie mieszkańców województwa śląskiego
Autorzy:
Krupa, Karolina
Piekut, Agata
Złotkowska, Renata
Powiązania:
https://bibliotekanauki.pl/articles/1178779.pdf
Data publikacji:
2012
Wydawca:
Instytut Medycyny Wsi
Tematy:
health risk
indoor air pollution
risk perception
Opis:
Introduction. Population increasingly draws attention to the issues concerning the environment degraded by the progress of civilization and the impact of this process on health. However, public awareness of the risk exposure to indoor contaminants is lagging a long way behind knowledge regarding outdoor environmental hazards. The aim of the study was to assess the risk perception related to exposure to indoor environmental factors in the population of Silesia. Materials and methods. In this study the electronic version of a questionnaire survey – downloaded on the website www.moja-ankiety.pl. was used. During the 3-months duration of the project 552 subjects participated in the survey. In the study participated the Silesian Voivodeship inhabitants such as chat rooms users, newsgroups and online forum participants. Data analysis was performed by using statistical program – STATA Version 8 SE [9], where the Kruskall-Wallis test and χ 2 test were applied. Statistical significance was assessed at p value *0.05. Results. Despite the low perception of environmental health hazards inside the dwellings, the majority of respondents were able to indentify health effects and ways to reduce exposure to indoor air pollution. Both gender, place of residence, education level and age significantly affected the level of perception of respondents on the risk connected with exposure to indoor air pollution. Conclusion. It is necessary to continuously work on raising public awareness of environmental health hazards in confined spaces, the causes of their occurrence, types, effects and above all the ways to counter these threats.
Wstęp. Populacja mieszkańców zwraca coraz większą uwagę na kwestie związane z degradacją środowiska w wyniku postępu cywilizacyjnego i skutku tego procesu na zdrowie. Jakkolwiek ich świadomość narażenia na zanieczyszczenia wnętrz jest znacznie mniej zaawansowana w stosunku do zagrożeń środowiskowych z zewnątrz. Celem tego badania była ocena ryzyka związanego z narażeniem na czynniki środowiskowe wnętrz u mieszkańców województwa śląskiego. Materiały i metody. W tym badaniu zastosowano ankietę w wersji elektronicznej umieszczonej na stronie internetowej www.moja-ankiety.pl. W czasie trzymiesięcznych badań udział wzięło 552 uczestników, mieszkańców województwa śląskiego takich jak: użytkownicy czatów, grup dyskusyjnych i forów internetowych. Analiza danych była przeprowadzona przy użyciu programu statystycznego STATA Version 8 SE [9], gdzie zastosowano testy Kruskall-Wallis i χ 2. Istotność statystyczna była oceniona na poziomie wartości p*0,05. Wyniki. Pomimo niskiej percepcji odnośnie zdrowotnych zagrożeń środowiskowych wewnątrz pomieszczeń, większość respondentów była w stanie ocenić skutki zdrowotne i sposoby ograniczenia narażenia na zanieczyszczenia powietrza wnętrz. Zarówno płeć, miejsce zamieszkania, poziom wykształcenia jak i wiek wywierały znaczny wpływ na poziom percepcji respondentów co do ryzyka związanego z narażeniem na zanieczyszczenie powietrza wewnątrz. Wnioski. Koniecznym jest stałe podnoszenie społecznej świadomości dotyczącej środowiskowych zagrożeń zdrowia w pomieszczeniach zamkniętych, przyczyn ich powstawania, rodzajów, skutków i przede wszystkim sposobów zwalczania tych zagrożeń.
Źródło:
Medycyna Środowiskowa - Environmental Medicine; 2012, 15, 3; 46-54
1505-7054
2084-6312
Pojawia się w:
Medycyna Środowiskowa - Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor air particles in office buildings with suspected indoor air problems in the Helsinki area
Autorzy:
Lappalainen, Sanna
Salonen, Heidi
Salmi, Kari
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2179800.pdf
Data publikacji:
2013-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
particle counts
indoor air
supply air
office
health effects
Opis:
Objectives: Airborne particle concentrations can be used as quality indicators of indoor environments. The previous lack of reference data has limited the use of particle measurements in offi ce environments. The aim of this study was to describe the concentrations of airborne particles (≥ 0.5 μm and ≥ 5.0 μm) in 122 Finnish offi ce buildings with suspected indoor air problems. Materials and Methods: The database consisted of indoor air and supply air particle samples collected in 2001–2006 from the Helsinki area. The particle concentrations (≥ 0.5 μm and ≥ 5.0 μm) were measured in the indoor air (528 samples from 122 offi ce rooms) and in the supply air (384 samples from 105 offi ce rooms) with an optical particle counter. Airborne particle concentrations ≥ 0.5 μm were categorized according to the effi ciency of supply air fi ltration and health survey data. Results: The mean concentrations in the indoor air equaled 1900 particles/l and in the supply air 1300 particles/l. The effi ciency of supply air fi ltration decreased the fi ne particles counts in both the indoor and supply air. The counts of large particles, ≥ 5.0 μm, were low in the indoor air. Airborne counts of ≥ 0.5 μm particles (geometric mean) were statistically higher in the offi ces whose occupants had work-related symptoms (eye and/or upper respiratory symptoms or upper respiratory infections) than in the offi ces whose occupants had no such symptoms. However, the symptoms may also be linked to other indoor air problems or particle characteristics not studied in this work. Conclusions: This study indicates typical airborne particle levels (≥ 0.5 μm and ≥ 5.0 μm) in Finnish offi ce buildings with suspected indoor air problems. The results can be used to evaluate the quality of indoor environment, possible indoor air problems, and the need for additional investigations.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 1; 155-164
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photodegradation of Lower Polybrominated Diphenyl Ether Congeners in Indoor Air – Model Studies
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124336.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PBDEs
indoor air quality
flame retardants
photolytic degradation
Opis:
Polybrominated diphenyl ethers (PBDEs) are additive flame retardants which have found applications in polymers for many consumer plastic and electronic goods. Wide use of these chemicals has led to their extremely high concentrations in the indor environments. This paper presents an exploratory study of the photodebromination of five individual lower polybrominated diphenyl ether congeners (BDE-28, BDE-47, BDE-99, BDE-100 and BDE-101) irradiated with white light and different UV (A, B, C) light ranges. The capability of photodegradation of lower PBDEs under room lights was proven by the debromination which occurred with various effectiveness for the selected PBDE congeners and depended of light source. Almost all PBDE congeners showed the greatest decay when exposed to UV-C, with the exception of BDE-100. The decay of irradiated congeners occurred rapidly during the first 5 min of experiment. The final degradation varied from 38% decay (BDE-28, UV-C) to 94% (BDE-47, UV-C). These findings can help in predicting PBDE behavior in indoors and also be useful in the design of PBDE remediation processes.
Źródło:
Journal of Ecological Engineering; 2017, 18, 3; 180-186
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwość poprawy jakości powietrza w polskich szkołach w wyniku modernizacji opartej na zasadach zrównoważonego rozwoju
Autorzy:
Sowa, J.
Panek, A.
Powiązania:
https://bibliotekanauki.pl/articles/362510.pdf
Data publikacji:
2005
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
jakość powietrza wewnętrznego
zasada zrównoważonego rozwoju
indoor air quality
Opis:
The paper describes part of the results of the Polish/Norwegian scientific cooperation within the project SUREBUILD, funded by the Norwegian Ministry of Foreign Affairs. The whole project is devoted to sustainable redevelopment of buildings in Poland, but special attention was paid to Polish schools constructed between 1958-1966 (the "Millenium" schools). Potential technologies for sustainable modernization of Polish schools were analyzed taking into consideration energetic, environmental, economic and other related criterions. Substantial part of the work was devoted to fin d the economically feasible technologies that might improve current unsatisfactory level of indoor air quality in Polish schools. The paper presents general recommendations for the moderniza- tion of ventilation system s in Polish schools as well as describes the technologies selected for school in Zgierz, the case study object of the project.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2005, T. 1; 305-314
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in a Selected Health Resort Facility: Analysis of PM10, PM2.5 and 222Rn Concentrations
Autorzy:
Merenda, Beata
Maciejewski, Piotr
Bezyk, Yaroslav
Sówka, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/2202169.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
health resort
indoor air
particulate matter
PM
222Rn
Opis:
This paper discusses the importance of indoor air quality and indicates its relation with outdoor air quality in the area of spa treatment. Significant factors and sources causing indoor air pollution by particulate matter and radon are considered. Particular attention is drawn to specific functions of health resorts in spa treatment in the context of the importance of indoor and outdoor air for patients staying in the resorts. It is underlined the specificity of health resorts providing treatment for patients classified as the group most sensitive to air pollution, i.e. people with chronic respiratory diseases. The study comprised measurements of 24-h concentrations of PM10, PM2.5 and 10-minute instantaneous concentrations of radon-222 (222Rn) from February 5 to February 25, 2021 in a treatment room of one of the Polish spas located in Lower Silesia. The analysis of interactions between the concentrations of two fractions of particulates PM10 and PM2.5 was presented. The interaction and dependence of factors affecting the elevated values of concentrations of the studied pollutants were discussed. The presented analyses showed that the concentrations of the studied pollutants were influenced by air exchange and air infiltration from outside to inside. In the case of short-term measurements of 222Rn activity concentration in the air, it was found that the observed changes in hourly concentrations of 222Rn are analogous to those observed in residential buildings. For the specific time intervals, the variation of PM concentrations and 222Rn activity concentration was found to be similar.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 202--215
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Empirical cumulative distribution function of CO2 concentration increments as a descriptor of indoor air variability
Autorzy:
Szczurek, A.
Maciejewska, M.
Pietrucha, T.
Powiązania:
https://bibliotekanauki.pl/articles/208271.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
carbon dioxide
air quality
carbon
indoor air pollution
indoor air quality
indoor environment
dwutlenek węgla
jakość powietrza
węgiel
zanieczyszczenie powietrza w pomieszczeniach
jakość środowiska wewnętrznego
środowisko wewnętrzne
Opis:
Indoor air quality broadly refers to the environmental characteristics inside buildings and characterizes the physical, chemical and biological state of indoor air at some place and time. Usually it is characterized by physicochemical properties of indoor environment such as temperature, relative humidity, airflows and concentration of characteristic pollutants, e.g. carbon dioxide. They are highly variable in time. In the paper, changes of empirical cumulative distribution function (ECDF) of CO2 concentration were considered as a descriptor of indoor air variability. Using this measure, there may be performed the analysis of CO2 variation in a short as well as long term. The approach utilizes the idea of classification. A class of variation of CO2 concentration has its individual ECDF. It indicates a particular case of balance/imbalance between CO2 delivery and removal processes, including gas dispersion. The analysis is applicable for evaluating the stability of indoor environment and it may provide support for the diagnosis of the performance of the air exchange system. Exemplary results were provided for an open space office and a lecture theater.
Źródło:
Environment Protection Engineering; 2015, 41, 3; 173-187
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The capability of fungi isolated from moldy dwellings to produce toxins
Autorzy:
Jeżak, Karolina
Kozajda, Anna
Sowiak, Małgorzata
Brzeźnicki, Sławomir
Bonczarowska, Marzena
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2168358.pdf
Data publikacji:
2016-07-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
indoor air
mycotoxins
molds
residential environment
sterigmatocystin
roquefortine C
Opis:
Objectives The main objective was analysis and assessment of toxinogenic capabilities of fungi isolated from moldy surfaces in residential rooms in an urban agglomeration situated far from flooded areas in moderate climate zone. Material and Methods The assessment of environmental exposure to mycotoxins was carried out in samples collected from moldy surfaces in form of scrapings and airborne dust from 22 moldy dwellings in winter season. In each sample 2 mycotoxins were analyzed: sterigmatocystin and roquefortine C produced by Aspergillus versicolor and Penicillium chrysogenum, respectively. Mycotoxins were analyzed by high-performance liquid chromatography (HPLC) in: scrapings from moldy surfaces, mixture of all species of fungi cultured from scrapings on microbiological medium (malt extract agar), pure cultures of Aspergillus versicolor and Penicillium chrysogenum cultured from scrapings on microbiological medium; mycotoxins in the indoor air dust were also analyzed. Results The production of sterigmatocystin by individual strains of Aspergillus versicolor cultured on medium was confirmed for 8 of 13 isolated strains ranging 2.1–235.9 μg/g and production of roquefortine C by Penicillium chrysogenum for 4 of 10 strains ranging 12.9–27.6 μg/g. In 11 of 13 samples of the mixture of fungi cultured from scrapings, in which Aspergillus versicolor was found, sterigmatocystin production was at the level of 3.1–1683.2 μg/g, whereas in 3 of 10 samples in which Penicillium chrysogenum occurred, the production of roquefortine C was 0.9–618.9 μg/g. The analysis did not show in any of the tested air dust and scrapings samples the presence of analyzed mycotoxins in the amount exceeding the determination limit. Conclusions The capability of synthesis of sterigmatocystin by Aspergillus versicolor and roquefortine C by Penicillium chrysogenum growing in mixtures of fungi from scrapings and pure cultures in laboratory conditions was confirmed. The absence of mycotoxins in scrapings and air dust samples indicates an insignificant inhalatory exposure to mycotoxins among inhabitants in moldy flats of urban agglomeration situated far from flooded territories. Int J Occup Med Environ Health 2016;29(5):823–836
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2016, 29, 5; 823-836
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perceived indoor air quality and psychosocial work environment in office, school and health care environments in Finland
Autorzy:
Tähtinen, Katja
Remes, Jouko
Karvala, Kirsi
Salmi, Kari
Lahtinen, Marjaana
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2116581.pdf
Data publikacji:
2020-06-16
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
Indoor Air Questionnaire
school
health care
perceived indoor environment
reference material
office
Opis:
ObjectivesThe study examined the extent and prevalence of perceived indoor environment-related (IE-related) symptoms environmental complaints and psychosocial work environmental factors in Finnish office, school and health care environments.Material and MethodsThe data were collected from non-industrial workplaces (N = 455) in 2011–2012 and 2015–2017 using the Finnish Institute of Occupational Health’s Indoor Air Questionnaire (IA Questionnaire). Suspicion of IE-related problems was reported in 59% of workplaces. The data consisted of 28 826 employees’ responses.ResultsThe employees reported symptoms and environmental discomfort in office environments less often than in school or health care environments. The most often reported IE-related complaints were stuffy air (39% of respondents), dry air (34%) and insufficient ventilation (33%). The most often reported symptoms were irritation of the nose (27% of respondents), irritation of the eyes (26%), and hoarse or dry throat (24%). The results showed differences between the perceived IE in office, school and health care environments.ConclusionsCompared to earlier findings, the most often perceived IE-related symptoms and complaints have increased in Finnish health care environments. The office employees’ perceptions of psychosocial work environment remained fairly unchanged whereas health care personnel more often assessed their psychosocial environment as positive compared to previous reports. Instead of exact reference values, comparing the results of IA Questionnaires with the distributions and mean values of the results of this study may be more informative for those striving to solve IE-related problems. The presented distribution and mean values of perceived symptoms, environmental complaints and psychosocial work environment might help to relate the results to other workplaces. This, in turn, might increase the understanding that IA Questionnaire results are influenced by many factors. The results presented can be used as new reference material when interpreting the results of IA Questionnaires in office, school and health care environments.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2020, 33, 4; 479-495
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of integrated indoor environmental air quality parameters in selected church buildings of Faisalabad city: a statistical based comparative study
Autorzy:
Hussain, Zahid
Khan, Mohammad S.
Kundi, Kundi
Alaf, Kashif
Ullah, Yasir
Powiązania:
https://bibliotekanauki.pl/articles/35518580.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
indoor air quality
church buildings
particulate matter
public health
air pollution
Opis:
The objective of this study is to control the air quality parameters for a selected range of different particulate matters. A comprehensive experimental approach is established to regulate the quality of air about a selected range of different air pollutants being investigated in the indoor atmosphere of the church building. Relative humidity, temperature, carbon dioxide, particulate matter and radon were considered as the factors of air quality extents. For establishing the association among the selected parameters, the data were mathematically analyzed. The correlation coefficient confirmed a strong relationship between the indoor CO2 level and the number of public. A negative relationship between the indoor CO2 extent and indoor temperature confirmed that due to the increase in temperature the concentration of CO2 decreased as well. A solid adverse connection among indoor relative humidity and indoor air temperature showed that due to the increase in air temperature, the level of the relative humidity decreased. Some recommendations were proposed for the treatment of air quality in church buildings for human well-being.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 134-147
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diversity of yeast-like fungi and their selected properties in bioaerosol premises utility
Wybrane właściwości grzybów drożdżopodobnych na tle ich różnorodności w bioaerozolu pomieszczeń użyteczności publicznej
Autorzy:
Ejdys, E.
Dynowska, M.
Biedunkiewicz, A.
Sucharzewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/67185.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
diversity
yeast-like fungi
bioaerosol
school building
room
indoor air
Opis:
A total of 69 isolates of yeasts were recorded in the indoor air of the school buildings: 43 in heated rooms and 26 in unheated rooms. Perfect stages prevailed. Fungi isolated in our study belonged to 39 species. These were mostly monospecific isolates although five two-species isolates were noted. Differences in the properties of physiological characters of fungi isolated in both study seasons were observed. As indoor and outdoor air does not mix during the heating season, a specific substrate for prototrophic, non-fermenting yeastlike fungi forms. Acid production allows fungi to dissolve inorganic compounds in building structures and to release needed microcomponents. Abilities to produce carotenoid pigments are clearly promoted in yeast-like fungi living indoor. This may be related to the accumulation of compounds that are indirect stages in the cycle of biosynthesis of carotenoids or a surplus of oxidizing compounds.
Znaczną część biocenozy budynków stanowią trudno wykrywalne grzyby z różnych grup taksonomicznych. U podstawy niepowodzeń w hodowli i izolacji drożdżaków z bioaerozolu wewnętrznego leży zbyt mała wiedza dotycząca ekofizjologii izolatów bytujących w pomieszczeniach. Dlatego celem badań było poznanie niektórych właściwości drożdżaków, ułatwiających im przeżywanie w środowisku pomieszczeń. Materiałem do badań były grzyby drożdżopodobne uzyskane z bioaerozolu 26 pomieszczeń szkolnych o różnym sposobie użytkowania poddanych częściowej modernizacji. Próby pobierano w okresie grzewczym (listopad) i po wyłączeniu ogrzewania (maj). Określano morfologię uzyskanych izolatów grzybów, stadium rozwojowe, zdolności strzępkowania i wytwarzania chlamydospor oraz wybrane cechy biochemiczne: zdolności fermentacyjne, źródła węgla i azotu, przyswajanie witamin, wytwarzanie kwasów oraz zdolności syntezowania barwników. Ogólna liczba grzybów w bioaerozolu badanych pomieszczeń wynosiła wiosną od 314 do 3577 jtk/m 3, natomiast jesienią od 79 do 1533 jtk/m 3 . Z powietrza wewnętrznego w badanych budynkach uzyskano łącznie 69 izolatów drożdży: 43 z pomieszczeń ogrzewanych i 26 z nieogrzewanych. Dominowały stadia doskonałe. Wyizolowane grzyby należały do 39 gatunków. Na ogół izolaty były jednogatunkowe, natomiast w pięciu przypadkach stwierdzono izolaty dwugatunkowe. Zaobserwowano różnice w cechach fizjologicznych grzybów izolowanych w obu sezonach badawczych. Nie mieszanie się powietrza zewnętrznego i wewnętrznego pomieszczeń w okresie grzewczym stwarza specyficzne siedlisko dla prototroficznych, nie fermentujących grzybów droż-dżopodobnych. Produkcja kwasu umożliwia grzybom rozpuszczanie związków nieorganicznych w konstrukcjach budowlanych i uwalnianie potrzebnych mikroskładników. Zdolności wytwarzania barwników karotenoidowych, są wyraźnie promowane u drożdżaków bytujących w pomieszczeniach, co być może wiąże się z nagromadzeniem związków będących pośrednimi etapami w cyklu biosyntezy karotenoidów oraz nadmiarem związków utleniających.
Źródło:
Acta Mycologica; 2014, 49, 1
0001-625X
2353-074X
Pojawia się w:
Acta Mycologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Dispersion of Nitrogen Dioxide and Carbon Monoxide in the Indoor Café – Case Study
Autorzy:
Al-Sultan, Ammar A.
Jumaah, Ghufran F.
Al-Ani, Faris H.
Powiązania:
https://bibliotekanauki.pl/articles/124047.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
indoor air pollutants
nitrogen dioxide
carbon monoxide
global standard
smoker
Opis:
A popularity café in Baghdad city was chosen to measure the dispersion of nitrogen dioxide (NO2) and carbon monoxide (CO) as examples of the Indoor Air Pollutants (IAPs) which are considered a significant environmental problem. The aims of this research were, firstly, to measure the variation of NO2 and CO concentrations; secondly, to examine the effect of the seasonal variation of indoor temperature (°C) and relative humidity (%) on the dispersion of both NO2 and CO and finally to compare the results with those of the global standards. The volume of café was about 360 m3 and the number of smokers was about 25-35 smoker/day. This work was divided into two parts where the first part includes the experimental work which comprised the measurement of NO2 and CO by GIGs devices. It was lasted about five months commencing from November 2017 to March 2018 and the readings were taken during two intervals at partial time and during peak time. The second part includes the analysis of obtained results and compared the results of those of the global standards for the Indoor Air Quality suggested by WHO, EPA, and European criteria in order to achieve the goals of this work. The results from this research have highlighted a clear increase in the concentrations of NO2 and CO along with the growing numbers of smokers. Furthermore, the concentrations of NO2 and CO were close to some global standard values of short-term exposure at peak time.
Źródło:
Journal of Ecological Engineering; 2019, 20, 4; 256-261
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of viable fungi in indoor air: a case study from Tagore’s residence at Jorasanko, India
Autorzy:
Bhattacharyya, S.
Mukherjee, D.
Sarkar, P.
Ghosh, S.
Samaddar, B.
Chaudhuri, P.
Powiązania:
https://bibliotekanauki.pl/articles/11560.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
assessment
viable fungi
fungi
indoor air
indoor environment
Tagore’s residence
Jorasanko
India
Opis:
Indoor environment is significant with respect to human health especially if it is concerned when the building is v. Aim of very old. In the present study was to assess the presence of airborne fungi at an old building in Kolkata India where lots of tourists are exposed every day. Residence of famous Nobel laureate poet Rabindranath Tagore (built in the 18th century and presently used as a famous museum) in Kolkata, West Bengal was selected for this study and the indoor fungi from different room of the museum were assessed by using exposure plate technique. Humidity, temperature, wind speed and illuminance were also measured by hygrometer, thermometer anemometer and lux-meter respectively. The fungal species isolated from the air samples of different rooms were Aspergillus sp., Penicillium sp., Paecilomyces sp., Trichoderma sp, Alternaria sp Verticillium sp, Fusarium sp, Cladosporium sp, Yeast, Curvularia sp. and Helminthosporium sp. among them, Aspergillus sp. (71.4% at monsoon at library), Penicillium sp (57% at summer at library), Paecilomyces sp.(91% at monsoon at manuscript room) are mostly dominated pathogens, which may harm the workers and visitors of the museum. No significant correlation among colony forming unit of fungi with illuminance, wind speed and temperature in the tested indoor environment was noted whereas, the humidity in indoor environment played a crucial (P<0.05) role. Round the year humidity control may be required for maintaining healthy environment.
Źródło:
International Letters of Natural Sciences; 2015, 06
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Survey of indoor air pollution and health symptoms at residential buildings
Autorzy:
Sarkar, S.
Nandy, A.
Talapatra, S.N.
Basu, R.
Mukhopadhyay, A.
Powiązania:
https://bibliotekanauki.pl/articles/11531.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
indoor air
air pollution
air pollutant
household product
human health
hazard symptom
residential building
Opis:
This survey work summarizes the generation of indoor air pollutants (IAPs) through household products and activities and also the probable health symptoms of IAPs were discussed through questionnaire in the residential buildings of urban and semi urban area when compared to rural (control) area by door to door survey. The IAPs are categorized as physical, chemical and biological and surveyed as per the product(s) usage in the closed room of buildings. The survey results of IAPs generated from household products and activities, these are asbestos, fine particulate matters and ash as physical pollutants. The chemical pollutants are carbon mono and di oxide gases, phthalates; DDT, chlordane, heptachlor, o-phenylphenol; PBDEs, Formaldehyde, Other Aldehydes, lead, benzene, chloroform, para-dichlorobenzene, methylene chloride, perchloroethylene, styrene, benzene, formaldehyde, terpenes, styrene, phthalate esters, toluene, Propellant, pesticides, PAH, NOx, acrylamide, VOCs, acetone, HCl gas and biological pollutants are bacteria, fungi, viruses, house dust mites, animal dander; cockroaches, microbial spore. In respect to established health impact data, the health symptoms were recorded after survey in two areas viz. urban and semi urban area. The health symptoms were recorded as eye, nose, and throat irritation; allergic reactions, respiratory irritation, aggravated asthma, influenza and other infectious diseases may be the generation of IAPs. The urban and semi urban area are compared with rural (control) area in which no symptoms were found as per discussion. In the present survey it was concluded that the generation of IAPs may from household products and activities in the urban and semi urban area due to less ventilation facilities when compared to rural (control) area. This is a preliminary observation, further researches are needed in relation to measurement of physical, chemical and biological indoor pollutants in closed room of residential buildings and also health hazards study of residents by haematological, biochemical, enzymological and genotoxicological parameters.
Źródło:
International Letters of Natural Sciences; 2014, 08, 1
2300-9675
Pojawia się w:
International Letters of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of indoor air quality in a store with additional gas heater
Autorzy:
Wysocka, Monika
Załuska, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1177489.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
air pollution
carbon dioxide
gas heater
heating
indoor air quality
thermal comfort
ventilation
Opis:
The quality of the internal environment is an extremely important issue, because users of rooms spend a significant part of the day inside buildings. The quality of the environment is largely dependent on the quality of the indoor air. The parameters of the air we breathe affect our health and the comfort of use of the rooms. Poor indoor air quality can cause a decrease in human comfort and various illnesses and ailments. Therefore, care should be taken to ensure adequate ventilation in the rooms, especially those that have an additional source of pollutant emissions. The purpose of this work is to examine the effect of heating a commercial premises room with a gas heater on air quality. The following parameters were measured as part of the tests: carbon dioxide concentration, air temperature and relative air humidity. The most important parameter significantly affecting the deterioration of the quality of the interior microclimate is carbon dioxide, the level of which reached high values, well above the hygienic minimum (1000 ppm). In order to compare the values of the tested parameters, the measurements were carried out in two options - for a period of five days with the stove running and another two days without additional heating.
Źródło:
World Scientific News; 2018, 102; 209-216
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologiczna jakości powietrza w zakładach piekarniczych
The assessment of microbiological indoor air quality in bakeries
Autorzy:
Wołejko, E.
Kowaluk-Krupa, A.
Wydro, U.
Butarewicz, A.
Jabłońska-Trypuć, A.
Piekut, J.
Dec, D.
Łoboda, T.
Powiązania:
https://bibliotekanauki.pl/articles/399933.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
piekarnie
bakterie
grzyby
zanieczyszczenie powietrza
bacteria
fungi
indoor air quality
bakeries
Opis:
Celem niniejszej pracy była ocena stanu jakości mikrobiologicznej powietrza w zakładach piekarniczych zlokalizowanych na terenie województwa podlaskiego. Badania wykonano jesienią 2014 roku na terenie trzech zakładów piekarniczych. Próby powietrza pobierano metodą zderzeniową z użyciem próbnika powietrza MAS-100 (Merck, Niemcy). Mikrobiologiczne badania powietrza obejmowały oznaczenie ogólnej liczby bakterii psychrofilnych i mezofilnych, bakterii wskaźnikowych tj. bakterii z gatunku Pseudomonas fluorescens, gronkowców mannitolododatnich i manitoloujemnych oraz grzybów pleśniowych znajdujących się w powietrzu atmosferycznym. Zanieczyszczenie powietrza wewnętrznego w badanych piekarniach pod kątem mikrobiologicznym różniło się w zależności od rodzaju lokalizacji zakładu produkcyjnego. Stężenia występujących wewnątrz zakładów bakterii mezofilnych i Staphylococcus mannitolododatnich oraz mannitoloujemnych przekraczały wartości graniczne określone dla powietrza niezanieczyszczonego. Nie odnotowano natomiast w analizowanych piekarniach nadmiernego zanieczyszczania powietrza grzybami pleśniowymi. Najwyższą liczbę grzybów w powietrzu wykryto w piekarni 1, natomiast w pozostałych piekarniach ich liczba utrzymywała się na poziomie czystego powietrza atmosferycznego.
The aim of this study was to assess microbiological indoor air quality of selected bakeries located in the region of Podlasie. The microbiological studies were conducted in autumn in 2014 in three selected bakeries. Microbiological air counts were measured by impaction using an air sampler MAS-100 NT. The microbiological air studies, comprised the determination of the total number of psychrophilic and mesophilic bacteria, namely indicator bacteria such as: bacteria of the species Pseudomonas fluorescens, mannitol-positive and mannitol-negative Staphylococc, the total number of bacteria from the Enterobacteriaceae family and fungi found in atmospheric air. The results of the study of indoor air polluted with the analyzed groups of microorganisms differed depending on the type of test air and the location of the manufacturing plant. In the plants, the concentration of mesophilic bacteria and mannitol–positive and mannitol-negative Staphylococcus exceeded the limit values of unpolluted air, according to the Polish Standard recommendations.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 182-188
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Semivolatile compounds in schools and their influence on cognitive performance of children
Autorzy:
Hutter, Hans-Peter
Haluza, Daniela
Piegler, Kathrin
Hohenblum, Philipp
Fröhlich, Marina
Scharf, Sigrid
Uhl, Maria
Damberger, Bernhard
Tappler, Peter
Kundi, Michael
Wallner, Peter
Moshammer, Hanns
Powiązania:
https://bibliotekanauki.pl/articles/2179136.pdf
Data publikacji:
2013-08-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
children’s health
cognitive performance
indoor air pollution
semivolatile compounds
TCEP
Opis:
Objectives: WHO's Children's Environment and Health Action Plan for Europe (CEHAPE) focuses on improvements of indoor environments where children spend most of their time. To investigate the relationship between school indoor air pollutants and cognitive performance in elementary school children, a multidisciplinary study was planned in all-day schools in Austria. Materials and Methods: In a cross-sectional study (LuKi study: Air and Children) indoor air pollutants were monitored in nine elementary all-day schools in urban and rural regions of Austria. In addition, school dust and suspended particulates ($\text{PM}_\text{10}$, $\text{PM}_\text{2.5}$) were measured, focusing on semivolatile compounds (e.g. phthalates, phosphororganic compounds [POC]). Health status and environmental conditions were determined by parents' questionnaire, cognitive function was measured by Standard Progressive Matrices (SPM). Results: Overall, 596 children (6-8 years of age) were eligible for the study. Cognitive tests were performed in 436 children. Analysis showed significant correlations of tris(2-chlorethyl)-phosphate (TCEP) in $\text{PM}_\text{10}$ and $\text{PM}_\text{2.5}$ and school dust samples with cognitive performance. Cognitive performance decreased with increasing concentrations of TCEP. Furthermore, cognitive function decreased significantly with increasing CO₂ levels. Conclusions: POC are widely used as plasticizers, flame retardants and floor sealing. This is the first report of a correlation between TCEP in indoor air samples and impairment of cognitive performance in school children. As a precautionary measure, it is recommended to prohibit the use of toxic chemicals and those suspected of a toxic potential in children's environments such as schools.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 4; 628-635
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grzyby pleśniowe w oazach sprzyjającego mikroklimatu
Autorzy:
Stawiski, B.
Powiązania:
https://bibliotekanauki.pl/articles/163713.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
powietrze wewnętrzne
jakość powietrza wewnętrznego
kondensacja wilgoci
wilgotność powietrza
grzyb pleśniowy
rozwój pleśni
analiza przyczyn
indoor air
indoor air quality
damp condensation
air humidity
mould
mould growth
causes analysis
Opis:
Ograniczenie dopływu powietrza do powierzchni przegród na skutek niewłaściwego użytkowania (zastawienie ścian meblami, książkami) lub niezgodnych z zasadami sztuki budowlanej, samodzielnych przeróbek systemu wentylacji (brak nawiewu, zamiana kanałów pionowych na poziome) prowadzi do nadmiernej wilgotności względnej powietrza (czasem lokalnie, czasem w całym mieszkaniu) i wykraplania się pary wodnej na przegrodach budowlanych. W artykule przedstawiono przykłady korozji biologicznej na ścianach w źle wentylowanych strefach mieszkania pomimo niezłej wentylacji samego mieszkania jako całości. Zwrócono także uwagę na błędne interpretacje termogramów, błędne wnioski o złej termoizolacji w oparciu o nieznaczne różnice temperatury na ścianach i w narożach, przy oknach i drzwiach. Pomijanie oczywistych zjawisk fizycznych związanych z przepływem ciepła należy uznawać za wadliwość badań termowizyjnych.
Źródło:
Przegląd Budowlany; 2017, 88, 10; 19-22
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Volatile organic compounds removal from vehicle interior based on photocatalytic solution
Autorzy:
Bury, P.
Górniak, A.
Janicka, A.
Zawiślak, M.
Michniewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/245126.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
automotive vehicle
benzene-toluene-xylene compounds
vehicle interior
indoor air
photocatalysis
Opis:
The article presents results of research work which aim was development of solution for volatile organic compounds (VOCs) removal from vehicle indoor air. VOCs, especially benzene, toluene, and xylene (BTX), are air pollutants responsible for many civilizational diseases because of its carcinogenic and mutagenic properties. Concentration of those substances can be even few times higher in micro atmosphere of vehicle cabin than in other indoor atmospheres [1]. The aim of the scientific cooperation between Dr. Schneider Automotive Polska and the Wroclaw University of Science and Technology (WUST) is research on innovative (international range), product development – photocatalytic reactor characterized by Volatile Organic Compounds, especially BTX removal properties. The BTX reduction effectiveness, caused by photocatalytic reactor application in vehicle ventilation system, was subjected to in-depth analysis. The results showed difference on not only maximal benzene, toluene, and xylene reduction (separately) but also in the pattern of response surface. In some tested parameters, the hazardous compounds (as a BTX sum) were reduced for almost 70%. The photocatalytic reactor seems to be prospective solution for air quality improvement in any vehicle cabin.
Źródło:
Journal of KONES; 2018, 25, 3; 77-84
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacterial and Fungal Aerosols in Air-Conditioned Office Buildings in Warsaw, Poland—The Winter Season
Autorzy:
Gołofit-Szymczak, M.
Górny, R. L.
Powiązania:
https://bibliotekanauki.pl/articles/90052.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
indoor air quality
office buildings
bacterial and fungal aerosols
size distribution
Opis:
The microbial quality of the working environment was assessed in winter in air-conditioned office buildings in Warsaw. The average indoor concentrations of bacterial and fungal aerosols were low (<103 cfu∙m–3), below Polish proposals for threshold limit values in public service buildings. Even during cold months, if the air-conditioning system works properly, people remain the main source of bacterial aerosol in offices, whereas infiltration of outdoor air remains a major mechanism responsible for their fungal contamination. An analysis of the bioaerosol size distribution showed that microbial propagules that reach both the upper and lower respiratory tract may evoke numerous adverse health effects from irritation and asthmatic reactions to allergic inflammation. A comparative analysis of viable and total airborne microbial counts showed that viable micro-organisms accounted for up to 0.3% of the total number of microbial propagules. Hence, a comprehensive hygienic assessment of office workplaces should include an efficient control of both these elements.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 4; 465-476
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of air quality on sleep and cognitive performance in school children aged 10–12 years: a double-blinded, placebo-controlled, crossover trial
Autorzy:
Klausen, Frida B.
Amidi, Ali
Kjærgaard, Søren K.
Schlünssen, Vivi
Ravn, Peter
Østergaard, Kirsten
Gutzke, Vibeke H.
Glasius, Marianne
Grønborg, Therese K.
Hansen, Stefan N.
Zachariae, Robert
Wargocki, Pawel
Sigsgaard, Torben
Powiązania:
https://bibliotekanauki.pl/articles/2203016.pdf
Data publikacji:
2023-05-23
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
sleep quality
cognition
indoor air
CO2 exposure
school children
RCT study
Opis:
Objectives To investigate the effect of CO₂ during sleep on next-morning cognitive performance in young schoolchildren, the authors performed a double-blind fully balanced crossover placebo-controlled study. Material and Methods The authors included 36 children aged 10–12 years in the climate chamber. The children slept at 21°C in 6 groups each at 3 different conditions separated by 7 days in a random order. Conditions were as follows: high ventilation with CO₂ at 700 ppm, high ventilation with added pure CO₂ at 2000–3000 ppm, and reduced ventilation with CO₂ at 2–3000 ppm and bioeffluents. Children were subjected to a digital cognitive test battery (CANTAB) in the evening prior to sleep and on the next morning after breakfast. Sleep quality was monitored with wrist actigraphs. Results There were no significant exposure effects on cognitive performance. Sleep efficiency was significantly lower at high ventilation with CO₂ at 700 ppm which is considered to be a chance effect. No other effects were seen, and no relation between air quality during sleep and next-morning cognitive performance was observed in the children emitting an estimated 10 l CO₂ /h per child. Conclusions No effect of CO₂ during sleep was found on next day cognition. The children were awakened in the morning, and spent from 45–70 min in well-ventilated rooms before they were tested. Hence, it cannot be precluded that the children have benefitted from the good indoor air quality conditions before and during the testing period. The slightly better sleep efficiency during high CO₂ concentrations might be a chance finding. Hence, replication is needed in actual bedrooms controlling for other external factors before any generalizations can be made.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2023, 36, 2; 177-191
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu środowiska wewnętrznego w wybranych przedszkolach. Cz. 1 Temperatura
Analysis of indoor environment in a kindergarten building. P. 1 Temperature
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403027.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
jakość powietrza wewnętrznego
wentylacja
mikroklimat
temperatura
indoor air quality
ventilation
microclimate
temperature
Opis:
Aby zapewnić dzieciom odpowiednie warunki sanitarno-higieniczne w pomieszczeniach przedszkolnych należy pamiętać o częstym wietrzeniu i nie przegrzewaniu pomieszczeń. Aby zapewnić dzieciom odpowiednie warunki sanitarno-higieniczne w pomieszczeniach należy więc zapewnić właściwą wentylację. Temperatura w pomieszczeniach jest parametrem stanu powietrza najbardziej odczuwalnym przez ludzi. Decyduje ona o samopoczuciu, wydajności w pracy, zapewnia tzw. komfort cieplny. Niewłaściwa temperatura, może doprowadzić do chorób. Badania prowadzono w trzech przedszkolach o różnej wielkości i różnej termoizolacyjności ścian zewnętrznych. Termomodernizację w poszczególnych przedszkolach wykonano w różnym czasie. Prowadzono badania jakości powietrza wewnętrznego w salach przedszkolnych. W artykule przedstawiono tylko wyniki dotyczące temperatury powietrza wewnętrznego badanych przedszkoli.
In order to ensure proper sanitary and hygienic conditions in a kindergarten building, one needs to remember about airing the rooms frequently and making sure that the temperature is not too high; this is why an efficient ventilation system is indispensable. Temperature is the parameter of indoor air whose influence people are most likely to feel. It is the decisive factor about their general physical and mental state and the efficiency of their work; temperature also ensures the socalled thermal comfort. A temperature that is either too high or too low may cause various diseases. The research was conducted in three kindergartens which varied in terms of the space of the facilities and thermal insulation of exterior walls. Thermomodernization in each kindergarten was carried out at a different time. The research focused on the quality of indoor air in particular rooms. This article discusses the results only with regard to air temperature in the kindergartens in question.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 4; 281-285
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry powietrza podczas pracy lakierni autobusowej na wybranym przykładzie
Air quality parameters during the operation of a bus paint shop on the basis of a selected example
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/315602.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
wentylacja
lakiernik
jakość powietrza wewnętrznego
ventilation
car paint shop
indoor air quality
Opis:
Zasadniczą treść tego artykułu stanowi przedstawienie parametrów powietrza wentylacyjnego, które wystąpiły podczas ich pomiarów, przeprowadzonych w czasie pracy lakierni autobusowej. Przedstawiono rozkłady temperatur, wilgotności względnej, prędkości ruchu powietrza w lakierni oraz stężenia dwutlenku węgla, a także wyciągnięto wnioski z wyników pomiarów. Omówiono także zagadnienia, związane z komfortem cieplnym oraz jego wpływem na warunki pracy pracownika w lakierni. Szczególny nacisk położono na scharakteryzowanie wpływu dwutlenku węgla na organizm ludzki. Zawarto również informacje o dopuszczalnych wartościach tego trującego gazu w pomieszczeniach lakierni, wynikające z obowiązujących przepisów.
The principal part of this paper is concerned with the presentation of air quality parameters and ventilation rates, which were registered during measurements conducted in a bus paint shop. The presentation includes the distribution of temperatures, relative humidity, velocity of air circulation in a paint ship along with concentration of carbon dioxide coupled with conclusions from the conducted measurements. In addition, the presentation includes the issues associated with thermal comfort and its impact on the working conditions in a paint shop. The paper also contains information regarding the maximum admissible levels of this pollutant on the premises of a paint shop, according to the regulations in force.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 199-203, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poziomy metali ciężkich w kurzu domowym z obszaru Lublina
Heavy metals levels in indoor dust from households of the Lublin area, Poland
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126741.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
metale ciężkie
kurz domowy
powietrze wewnętrzne
heavy metals
indoor air
house dust
Opis:
Dostępne badania literaturowe wskazują, że kurz domowy może być zapadliskiem dla wielu niebezpiecznych substancji chemicznych występujących w powietrzu wewnętrznym, np. średniolotnych związków organicznych (perfluorowanych, bromoorganicznych antypirenów, pestycydów, wielopierścieniowych węglowodorów aromatycznych), materii organicznej oraz metali, których pochodzenie może mieć charakter naturalny lub związany z działalnością człowieka. Kurz domowy może być szczególnie ważnym źródłem zatruć metalami ciężkimi wśród małych dzieci, które mimowolnie spożywają go w trakcie zabaw. W pracy przedstawiono charakterystykę potencjalnych źródeł metali ciężkich: Cd, Co, Cr, Cu, Ni, Pb, Zn i ich poziomów w kurzu domowym, zebranym w 30 lubelskich mieszkaniach.
Many studies have reported that household dust serves as a sink to hazardous substances including semivolatile organic compounds (perfluorinated compounds, brominated flame retardants, pesticides, PAHs), organic matter, and metals of both natural and man-made origin. Metal pollution in indoor dust, in particular heavy metals has been investigated from years in order to moderate elevation in children’s blood an the unintentional ingestion of indoor dust. Generally, contamination of indoor dust by metals can be a result of industrial activity, automobile emission and other indoor sources, eg paints, devices etc. This study pays attention to the potential sources and levels of selected heavy metals distributed in the households of the Lublin area, Poland, The highest concentrations from investigated metals have been found for Zn, Cu, Cr, Pb and Ni, respectively.
Źródło:
Proceedings of ECOpole; 2010, 4, 2; 489-493
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of exposure to fungi in the heavily contaminated work environment (a solid waste sorting plant) based on the ergosterol analysis
Autorzy:
Kozajda, Anna I.
Jeżak, Karolina
Sowiak, Małgorzata
Gutarowska, Beata
Szadkowska-Stańczyk, Irena
Powiązania:
https://bibliotekanauki.pl/articles/2177184.pdf
Data publikacji:
2015-07-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational exposure
bioaerosols
sterols
solid waste management plant
ergosterol
indoor air pollution
Opis:
Objectives This paper reports on the results of the study aimed at application of ergosterol as an quantitative indicator of fungal bioaerosol present in the indoor air in occupational environment heavily contaminated with organic dust as well as its comparison with the culturable method. Material and Methods The study was conducted in the indoor solid waste sorting plant. Using Andersen impactor adapted to 1 plate at the flow rate of 30 l/min, indoor air was sampled in the workers’ breathing zone. Ergosterol was sampled using gelatinous filter (1000 l of air) and then analyzed by means of the spectrophotometric method. Fungi were sampled on malt extract agar (MEA) medium (3 replications: 2 l, 7.5 l, 15 l of air) and analyzed by means of the culturable method. Based on ergosterol analyzes, concentration of fungi was calculated. Results were given as the range assuming min. as 5.1 pg ergosterol/spore and max as 1.7 pg ergosterol/spore. Results The average concentrations of ergosterol in a working room (arithmetic mean (AM), standard deviation (SD); minimum–maximum (min.–max)) were, respectively: 2.16, 0.72; 0.85–2.92 μg/m³; fungi calculated based on ergosterol – 424.1×10³–1272.4×10³, 140.1×10³– 420.4×10³, 167×10³–1716.5×10³ CFU/m³, and culturable fungi – 13×10³, 9.7×10³, 1.9×10³–34×10³ CFU/m³). It was revealed that concentrations of calculated fungi were even 2 orders of magnitude higher than culturable fungi. Conclusions The quantitative assessment of moldiness by means of ergosterol measurement seems to be a reliable indicator for environments heavily contaminated with organic dust, where viable and non-viable fungi are present in high proportions. Based on that result, more restrictive (as compared to a similar assessment carried out by means of the culturable method) hygienic recommendations, especially those related to the use of preventive measures protecting the employees’ respiratory tract, should have been undertaken.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 5; 813-821
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in Offices and Classrooms in Public Utility Building - a Case Study
Autorzy:
Łuszczyńska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/27314787.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
indoor air quality
bioaerosol
microorganisms
fungi
jakość powietrza w pomieszczeniach
bioaerozol
mikroorganizmy
grzyby
Opis:
A microbiological analysis of indoor air quality in offices, lecture rooms, and hallways in a public utility building has been carried out in the Lubuskie Voivodship (Poland). In one of the storage rooms, the presence of fungi on the building partition was found in the place of water infiltration as a result of a technological failure in the building. A total of 17 nonresidential interiors were examined. The total number of psychrophilic and mesophilic bacteria and the total number of fungi were sampled by the collision method with the air sampler. A qualitative analysis has been performed of fungi present in the indoor air and from building partition of the studied interiors. A total of 11 species of fungi have been specified. Relative humidity and air temperature were measured with a hygrometer. The studies showed that the number of psychrophilic bacteria in indoor air was in the range 0-730 CFU/m3 , while the number of mesophilic bacteria was slightly higher (0-896 CFU/m3 ). A high level of contamination and a large number of fungi (734 CFU/m3 ) were found in the indoor air of storage room, where the problem of biodeterioration of building partitions occurred. In the remaining rooms, the level of microorganisms was low or moderate. Microbiological tests of the outdoor air (background) did not reveal an excessive number of microorganisms in the air.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 3; 228--239
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozkład wybranych parametrów powietrza w hamowni samochodowej
Variability of selected air parameters in the premises containing a car dynamometer
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/315419.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
jakość powietrza wewnętrznego
dwutlenek węgla
hamownia
indoor air quality
carbon dioxide
car dynamometer
Opis:
W artykule scharakteryzowano pracę hamowni samochodowych omawiając szczegółowo ich rodzaje i przeznaczenie. Wskazano między innymi na warunki pracy w pomieszczeniach, w których znajdują się tego typu urządzenia diagnostyczne. Przedstawiono także podstawowe informacje o komforcie cieplnym, jaki należy stworzyć diagnostom realizującym swoje zadania w hamowni. Duży nacisk położono na omówienie szkodliwości występowania nadmiernego stężenia CO2 w pomieszczeniach i jego wpływ na organizm ludzki. W części eksperymentalnej zawarto informacje o zmierzonych parametrach powietrza wewnętrznego w hamowni, takich jak temperatura, wilgotność względna i stężenie dwutlenku węgla. Uzyskane wyniki pozwoliły na wyciagnięcie wniosków z których wynika, że zaistniałe podczas pracy hamowni warunki powietrza w pomieszczeniu nie odbiegały znacząco od prawidłowych. Wskazano także na konieczność wykonania dalszych badań.
The paper discusses the operation of a car dynamometer and includes details of its types and the designated use. Among other things, the conditions of operation in the premises containing diagnostic devices are indicated. The basic information about the thermal comfort, which needs to be secured for the work of diagnosticians performing their duties in the premises containing a dynamometer. An emphasis is placed on the discussion of the hazard posed by the excessive CO2 concentrations in the premises and its effects on the human body. The experimental part of the paper contains information regarding the measured parameters of internal air in the rooms containing a dynamometer, such as temperature, relative humidity and carbon dioxide concentration. The results enabled the statement of the conclusions which indicate that the ambient air conditions in the premises do not differ significantly from the acceptable results. The need to conduct further studies is also indicated.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 204-208, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunki rozwoju pomiarów zapachu i zawartości związków mVOC we wnętrzach budynków
Trends in odour measurements and determining mVOC content in the interiors of buildings
Autorzy:
Kostyrko, K. B.
Kozicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/267570.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odorant
powietrze wewnętrzne
moc
indoor air quality
IAQ
microbial volatile organic compounds
mVOC
Opis:
Praca zawiera zestawienie współczesnych technik służących do pomiarów zapachu jak również dopuszczalnych poziomów stężeń substancji uciążliwych zapachowo występujących we wnętrzach budynków. Scharakteryzowano lotne związki organiczne pochodzenia mikrobiologicznego, odpowiedzialne za różnego rodzaju zapachy, jak również techniki analityczne służące do ich chemicznej charakterystyki. Szczególną uwagę poświęcono elektronicznym nosom, będącym coraz powszechniejszymi, często przenośnymi, urządzeniami służącymi do monitorowania stężenia odorantów zapewniającymi analizę w czasie rzeczywistym.
The work summarizes contemporary techniques for odour measurements as well as permissible levels of concentrations of odorous substances occurring in the interiors of buildings. Microbial volatile organic compounds which are responsible for various smells have been characterized. The most suitable techniques for sampling and MVOC chemical characterization in indoor environments were reviewed. The olfactometric techniques are discussed and the strong and weak points of odour assessment through human detection are highlighted. Particular attention was paid to electronic noses, which are increasingly common, often portable, devices for monitoring the concentration of odorants providing real-time analysis.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 97-102
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba poprawy jakości powietrza wewnętrznego w przedszkolu
Indoor air quality in a preschool
Autorzy:
Koruba, D.
Zender-Świercz, E.
Piotrowski, J.Z.
Orman, Ł.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/390993.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
Opis:
W artykule przedstawiono wyniki badań nad jakością powietrza wewnętrznego (IAQ) w jednym z wybranych przedszkoli. W obiekcie zastosowany został system wentylacji grawitacyjnej. Wstępne badania potwierdziły niską jakość powietrza wewnętrznego w podmiotowym budynku. W trakcie badań zaproponowano dwa usprawnienia mające na celu poprawę jakości powietrza: zwiększenie strumienia powietrza nawiewanego oraz, w drugiej kolejności, montaż urządzeń do uzdatniania powietrza wewnętrznego. Uzyskane wyniki badań wskazują, że wprowadzone usprawnienia wpływają na poprawę jakości powietrza wewnętrznego.
The article demonstrates the results of research on the indoor air quality (IAQ) in one of chosen preschools. In such facilities, the standard solution is a system of natural ventilation. Only a small percentage of such buildings is equipped with a mechanical ventilation system with adjustable parameters of the microclimate. The article presents the results of indoor air quality in the local preschool located in Kielce. In the present facility natural ventilation system was used. Preliminary studies confirmed the poor quality of indoor air in a subjected building. During the study, two improvements aimed at improving air quality were proposed. The first improvement was to increase the supply air stream. The second one concerned the installation of equipment for the treatment of indoor air. The results indicate that under certain guidelines it is possible to improve indoor air quality. As an indicator of indoor air quality, concentration of carbon dioxide was adopted. In addition, microbiological tests were performed indoors.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 7-13
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza w wielorodzinnych budynkach mieszkalnych
Indoor air quality in multifamily buildings
Autorzy:
Telejko, M.
Zender–Świercz, E.
Piotrowski, J.Z.
Powiązania:
https://bibliotekanauki.pl/articles/390643.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
jakość powietrza wewnętrznego
mikroklimat
wymiana powietrza
fizyka budowli
indoor air quality
microclimate
air exchange
building physics
Opis:
Obowiązujące aktualnie przepisy prawne regulujące zagadnienia wentylacji naturalnej [1], [2], [3] w wielu obszarach są niejednoznaczne, a niekiedy wręcz sprzeczne. Sytuacja taka prowadzi do stosowania rozwiązań powodujących poważne zaburzenia w działaniu wentylacji grawitacyjnej. W dużej części budynków zaburzenia te są wynikiem dostarczania do pomieszczeń zbyt małej ilości powietrza zewnętrznego. Jak wykazały badania, ze względu na kształtowanie warunków mikroklimatu wnętrz, podstawowe znaczenie ma nie tylko wielkość dostarczanego strumienia powietrza zewnętrznego, ale również rozmieszczenie elementów doprowadzających to powietrze.
The applicable legislation connected with the natural ventilation are ambiguous and sometimes contradictory. This leads to serious problems with natural ventilation. In most cases malfunction of the natural ventilation is due to the insufficient stream of air from the outside. The research showed that the microclimate is influenced not only by the incoming air stream, but also by the layout of the air supply.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 67-74
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza rzeczywistych wartości wilgotności powietrza wewnętrznego
Analysis of results of indoor humidity measurements
Autorzy:
Mijakowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/362971.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
wilgotność
mikroklimat
pomiary
powietrze wewnętrzne
rozwój pleśni
humidity
microclimate
measurement
indoor air
mould growth
Opis:
W artykule przedstawiono analizę wieloletnich pomiarów parametrów powietrza wewnętrznego. Szczegółowo przeanalizowano wilgotność powietrza wewnetrznego. Przedstawiono statystyki wilgotności względnej dla różnych typów pomieszczeń , korelacje pomiędzy zawartością wilgoci w powietrzu zewnętrznym i wewnętrznym oraz ryzyko rozwoju pleśni na wewnętrznych powierzchniach przegród zewnętrznych o różnych współczynnikach przenikania ciepła. Przy określaniu ryzyka wzrostu pleśni posłużono sie modelem LIM (Lowest Isopleth for Mould[3]). Ponadto przedstawiono wyniki badań nad wilgotnością powietrza wewnętrznego, mogą stanowić dane wejściowe do różnorodnych obliczeń symulacyj- nych.
Long period measurements results of indoor parameters are presented. The paper focus on indoor humidity. The following analysis were presented: illustration of indoor thermal environment on psyhometric chart, histogram of indoor relative humidity, correlation between outdoor and indoor moisture content, and risk of mould growth on inside surface of building partitions with different U-value. The model of LIM (Lowest Isopleth for Mould [3] for risk of mould growth was implemented. Presented statistics may be used as an input for building simulation
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 209-214
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort in university computer laboratories
Komfort cieplny w pracowniach komputerowych uczelni wyższej
Autorzy:
Telejko, M.
Stachera, A.
Powiązania:
https://bibliotekanauki.pl/articles/402042.pdf
Data publikacji:
2018
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
PMV
PPD
microclimate
indoor air quality
komfort cieplny
mikroklimat
jakość powietrza wewnętrznego
Opis:
Thermal comfort defines the state of satisfaction of a person or a group of people with thermal conditions of the environment in which the person, or the group of people is staying. The state of satisfaction depends on the balance between the amount of heat produced by the organism in the process of metabolism and heat loss from the organism to the surrounding environment. It has an effect on the quality and efficiency at work, and indirectly also on the presence of symptoms of Sick Building Syndromes (SBS). Due to differences in body structure, metabolism, clothing etc., it is not possible to create a satisfactory thermal environment for all the people staying in it. However, there are parameter values, which maintained at an appropriate level, allow to meet thermal expectations of even 95% of people staying in this environment. The article presents the results of tests conducted in the university computer rooms. The studies included measurements and analysis of typical internal microclimate parameters: temperature, relative humidity and CO2 concentration. The results raised considerable reservations and therefore in order to assess fully the conditions of use, it has been decided to conduct evaluation of thermal comfort in rooms analysed. In addition, the surrounding surface radiation temperature and clothing insulation of users have been specified. On the basis of the obtained data, PPD and PMV index values were determined in accordance with the standard EN ISO 7730:2005 Ergonomics of the thermal environment – Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria [3].
Komfort cieplny określa stan zadowolenia osoby lub grupy osób z warunków termicznych środowiska, w którym osoba ta lub grupa osób przebywa. Ten stan zadowolenia zależny jest od równowagi pomiędzy ilością ciepła wytwarzanego przez organizm w procesie metabolizmu a stratami ciepła z organizmu do otaczającego go środowiska. Ma on wpływ na jakość i wydajność pracy, a pośrednio również na występowanie symptomów syndromów chorego budynku (SBS). Na skutek różnic w budowie ciała, metabolizmie, ubiorze etc. nie ma możliwości stworzenia środowiska cieplnego odpowiadającego wszystkim przebywającym w nim osobom. Istnieją jednak wartości parametrów, które utrzymane na odpowiednim poziomie, pozwalają na spełnienie oczekiwań termicznych nawet 95% ludzi przebywających w tym środowisku. W artykule zaprezentowano wyniki badań przeprowadzonych w pomieszczeniach komputerowych uczelni wyższej. Badania obejmowały pomiary oraz analizę typowych parametrów mikroklimatu wewnętrznego: temperatury, wilgotności względnej oraz stężenia CO2. Uzyskane wyniki budziły spore zastrzeżenia, dlatego w celu pełnej oceny warunków użytkowania zdecydowano się na przeprowadzenie oceny komfortu termicznego analizowanych pomieszczeń. Dodatkowo określono zatem temperaturę promieniowania powierzchni otaczających i izolacyjność odzieży użytkowników. Na podstawie otrzymanych danych wyznaczono wartości wskaźników PPD i PMV, zgodnie z normą EN ISO 7730:2005 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria [3].
Źródło:
Structure and Environment; 2018, 10, 3; 201-210
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor and Outdoor Concentrations of Particulate Matter and Gaseous Pollutants on Different Floors of a University Building: A Case Study
Autorzy:
Cichowicz, Robert
Dobrzański, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1839306.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
air quality monitoring
VOCs
H2S
PM10
PM2.5
indoor air quality
outdoor air quality
Opis:
In this study, we investigate the changes in the concentrations of suspended particulate matter (PM10 and PM2.5) and selected gaseous pollutants (VOCs, H2S) in the atmospheric air inside and outside a 9-story building, which is intended primarily for the teaching activities. The purpose was to determine whether the air quality inside the building is directly dependent on the outside air quality. The analysis also included the influence of the height of the building, its location and environment, as well as meteorological conditions. No clear correlation was found between the measured parameters inside and outside the building. The height above ground (the floor on which the measurements were made) was found to have a significant influence on the concentration of each pollutant. Wind direction was also found to have a very important impact on the air quality inside the building. A strong relationship was observed on the leeward side between the concentration of impurities on the inside and outside of the building.
Źródło:
Journal of Ecological Engineering; 2021, 22, 1; 162-173
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu środowiska wewnętrznego w wybranych przedszkolach. Cz. 2 Wilgotność względna
Analysis of indoor environment in a kindergarten building. P. 2
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403031.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
jakość powietrza wewnętrznego
wentylacja
mikroklimat
wilgotność względna
indoor air quality
ventilation
microclimate
relative humidity
Opis:
Najczęstszym objawem problemów z wymianą powietrza jest nadmierny wzrost wilgotności, który jest konsekwencją źle działającej wentylacji. Wilgotność względna powietrza w pomieszczeniu powinna się mieścić w granicach 30-65%, optymalna - 40-50%. Przebadano trzy przedszkola o różnej izolacyjności ścian zewnętrznych, aby ocenić stan środowiska wewnętrznego z uwzględnieniem wilgotności względnej. Badania wszystkich przedszkoli prowadzono w trzech seriach pomiarowych. Wilgotność powietrza w listopadzie i lutym, w budynkach po termomodernizacji, była poniżej zalecanych wartości. Powietrze było suche, mimo dużej wilgotności względnej powietrza zewnętrznego. W przedszkolu nie poddanym termomodernizacji, bez względu na porę roku, powietrze wewnętrzne było wilgotne.
Excessive rise of humidity is the most frequently observed sign of problems with air circulation, which often result from a faulty ventilation system. Relative humidity value indoors should range from 30% to 65%, the ideal being between 40% and 50%. The research was conducted in three kindergartens with different insulation of exterior walls; the objective was to assess the quality of indoor air with regard to relative humidity. Three series of measurements were taken in each of the kindergartens. In the building where thermomodernization was carried out, humidity values in February and November dropped below the recommended ones. Even though outdoor relative humidity was high, indoor air in this kindergarten was dry. In the kindergarten whose heating system has not been modernized, humidity values inside the building were appropriate regardless of the season.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 4; 287-291
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort measurements in the Energis building
Badania komfortu cieplnego w budynku Energis
Autorzy:
Białek, Anita
Koltuk, Bade
Powiązania:
https://bibliotekanauki.pl/articles/2055091.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
indoor air quality
thermal comfort
thermal responses
jakość powietrza wewnętrznego
komfort cieplny
odczucia cieplne
Opis:
In the paper the measurements of thermal comfort in the modern smart building “Energis” have been presented together with their analysis. The data have been obtained in the spring and the analyses of indoor air parameters as well as subjective responses of the volunteers have been conducted. Based on the performed studies it has been concluded that the people felt fine in the considered room (pleasantly warm, cool and comfortable) and described their feelings as acceptable and comfortable.
W artykule przedstawiono wyniki badań i analizę komfortu cieplnego w budynku inteligentnym „Energis”. Dane eksperymentalne uzyskano w okresie wiosennym, a analiza dotyczyła parametrów powietrza wewnętrznego, jak również subiektywnych odczuć ochotników. W oparciu o przeprowadzone badania można stwierdzić, że użytkownicy czuli się dobrze w rozpatrywanym pomieszczeniu (przyjemnie ciepło i chłodno, a także komfortowo) i ocenili swoje odczucia jako akceptowalne i komfortowe.
Źródło:
Structure and Environment; 2021, 13, 1; 10--15
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości powietrza wewnętrznego w wybranych przedszkolach
Indoor air quality in a preschool
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/391209.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
preschool building
Opis:
W artykule przedstawiono wyniki badań jakości powietrza wewnętrznego przeprowadzonych w 4 przedszkolach samorządowych. W rozpatrywanych obiektach zastosowany został system wentylacji grawitacyjnej. Uzyskane wyniki badań wskazują jednoznacznie na bardzo niską jakość powietrza w tego typy budynkach.
The article presents the results of indoor air quality (IAQ) assessment in four local preschools. The natural ventilation system was used in the buildings. Outdoor air was supplied to the premises through a leak in the external walls and air intakes were of maximum efficiency of 30 m3/h. Parameters describing IAQ were measured, such as: temperature, relative humidity and carbon dioxide concentration. Two series of studies were performed in each preschool. On the basis of the survey, it can be clearly stated that the indoor air quality in preschools is considered to be very low very low. All the analyzed parameters describing the quality do not meet the current legal requirements. Reported values of CO2 concentration exceeded three times the value set of the recommended maximum.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 41-48
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the internal microclimate using the questionnaires survey
Badania nad jakością mikroklimatu wewnętrznego z zastosowaniem kwestionariuszy ankietowych
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/402569.pdf
Data publikacji:
2013
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
building physics
indoor air quality
indoor climate
questionnaire surveys
fizyka budowli
jakość mikroklimatu wewnętrznego
jakość powietrza wewnętrznego
badania ankietowe
Opis:
This paper considers the subject of the applicability of survey research as an essential element for the assessment of the indoor microclimate. The results of the survey research are presented and compared with the experimental results performed in residential buildings.
Źródło:
Structure and Environment; 2013, 5, 4; 32-36
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary test results of thermal comfort in a classroom
Wstępne wyniki badań komfortu cieplnego w sali lekcyjnej
Autorzy:
Krawczyk, Natalia
Piasta, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/402066.pdf
Data publikacji:
2019
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
indoor air quality
thermal sensations
komfort cieplny
jakość powietrza w pomieszczeniu
odczucia termiczne
Opis:
The paper presents the issue of thermal comfort based on the conducted study. First, the definition and importance of thermal comfort was discussed. Then, air parameters were measured and surveys were conducted regarding questions about the assessment of thermal comfort of persons using the room. The list of the subject thermal comfort evaluation tests are illustrated in the diagrams. The impact of gender and BMI on the Predicted Mean Vote PMV were also analyzed. In the next part, results obtained from surveys and according to formulas from the standard were developed, and then compared.
W pracy przedstawiono zagadnienie komfortu cieplnego w oparciu o przeprowadzone badanie. Najpierw omówiono definicję i znaczenie komfortu cieplnego. Następnie wykonano pomiary parametrów powietrza oraz przeprowadzono ankiety dotyczące pytań o ocenę komfortu cieplnego osób użytkujących pomieszczenie. Zestawienia badań oceny komfortu cieplnego zilustrowano na wykresach. Analizie poddano także wpływ płci i wskaźnika BMI na przewidywaną średnią ocenę PMV. W kolejnej części opracowano wyniki otrzymane z ankiet oraz według wzorów z normy, a następnie je porównano.
Źródło:
Structure and Environment; 2019, 11, 4; 281-286
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort in intelligent buildings
Komfort cieplny w budynkach inteligentnych
Autorzy:
Majewski, G.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/402098.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
smart building
thermal comfort
indoor air quality
inteligentny budynek
komfort termiczny
jakość powietrza w pomieszczeniach
Opis:
The paper presents the issue of thermal comfort conditions with regard to intelligent buildings. First the principles of thermal comfort are discussed, namely the parameters affecting the human perception of the best indoor air conditions. Among the mentioned parameters indoor temperature seems to be especially vital for humans. In the second part the test results of temperature changes in the Energis building are presented together with the discussion.
Źródło:
Structure and Environment; 2016, 8, 1; 25-30
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Indoor Ultrafine Particulate Matter at the Sites of the Czech Armed Forces
Monitorowanie ultradrobnych cząstek w pomieszczeniach na terenach czeskich sił zbrojnych
Autorzy:
Kellnerova, Eva
Vecera, Zbynek
Kellner, Josef
Zeman, Tomas
Powiązania:
https://bibliotekanauki.pl/articles/319019.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
ultradrobne cząstki
powietrze w pomieszczeniach
jakość powietrza
ryzyko dla zdrowia
ultrafine particles
indoor air
air quality
health risk
Opis:
Ultrafine particles and nanoparticles in the air are evaluated as a risk factor for the development of respiratory and other health symptoms due to their inhalation from the ambient air. The Czech Army professionals are expected to have frequent presence in a polluted environment and regular exposure to air with increased concentration of airborne pollutants. The report evaluates the presence of ultra-fine particles (in the range of about 7.6–299.6 nm) in rooms often used by soldiers during their working hours when they are not deployed. The purpose is to assess whether the presence of troops in these workplaces is safe and does not pose a risk of adverse health effects in itself. Testing took place in three military rooms (classroom 1, classroom 2 and exercise flight simulator room). Seven samples of air were analysed in time by the scanning mobility particle sizer in succession. Mean particle concentrations were found at 1.79×104, 7.53×103 and 8.39×103 N·cm-3 for the classroom 1, classroom 2 and exercise flight simulator room. Conclusions of the research have shown that particle concentrations in the places of the Czech Army can reach values that border the immission limits stated by the World Health Organisation.
Najdrobniejsze cząstki i nanocząsteczki w powietrzu są oceniane jako czynnik ryzyka dla dróg oddechowych i innych objawów zdrowotnych spowodowanych ich wdychaniem z otaczającego powietrza. Oczekuje się, że specjaliści z czeskiej armii będą często obecni w zanieczyszczonym środowisku i będą regularnie narażeni na kontakt z powietrzem o zwiększonej koncentracji zanieczyszczeń. Raport ocenia obecność ultradrobnych cząstek (w zakresie około 7,6–299,6 nm) w pomieszczeniach często używanych przez żołnierzy w godzinach pracy. Celem jest ocena, czy obecność wojsk w tych miejscach pracy jest bezpieczna i sama w sobie nie stwarza ryzyka negatywnych skutków zdrowotnych. Testowanie odbyło się w trzech pomieszczeniach wojskowych (sala 1, sala 2 i sala do ćwiczeń). Siedem próbek powietrza analizowano w czasie przez separator cząstek. Stwierdzone średnie stężenia cząstek 1,79 × 104, 7,53 × 103 i 8,39 × 103 [N · cm-3] w sali lekcyjnej 1, klasie 2 i sali do ćwiczeń. Wnioski z badań wykazały, że stężenia cząstek w wybranych pomieszczeniach czeskiej armii mogą osiągnąć wartości graniczące z limitami imisji podanymi przez Światową Organizację Zdrowia.
Źródło:
Inżynieria Mineralna; 2019, 21, 1; 163-167
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Yeast-like fungi isolated from indoor air in school buildings and the surrounding outdoor air
Grzyby drozdzopodobne izolowane z powietrza budynkow szkolnych i powietrza atmosferycznego wokol nich
Autorzy:
Ejdys, E
Michalak, J.
Szewczyk, K.M.
Powiązania:
https://bibliotekanauki.pl/articles/67811.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
yeast-like fungi
fungi
isolation
indoor air
school building
outdoor air
building
biotic factor
abiotic factor
fungi species
Opis:
A total of 111 isolates of yeast-like fungi and yeasts belonging to 40 species of 19 genera were identified in indoor air and outdoor air. Only one species, Kluyveromyces marxianus, was recorded in both types of air and seasons (spring and autumn). Kluyveromyces lactis and Yarrowia lipolytica, a species having the greatest symbiotic abilities, dominated in indoor air and outdoor air, respectively. Intensely used rooms, especially those with limited access of air, have the broadest range of species of yeast-like fungi. A comparison of both habitats shows that school rooms pose a greater epidemiological risk of yeast-like infections than outdoor air. The indoor as well as outdoor mycobiota undergoes phenological changes although it is determined by other biotic and abiotic factors.
Podobnie jak w powietrzu wewnętrznym, największą część bioaerozolu powietrza atmosferycznego stanowią elementy grzybni i zarodniki grzybów z różnych grup systematycznych. Duże zagęszczenie grzybów drożdżopodobnych w powietrzu może stanowić poważne zagrożenie dla zdrowia oddychająch nim dzieci. Dlatego też postanowiono zbadać występowanie omawianych grzybów w powietrzu budynków szkolnych i wokół nich. Materiałem do badań były grzyby drożdżopodobne występujące przejściowo w powietrzu wokół budynków szkolnych oraz w ich wnętrzu. Grzyby pobierano w maju (ogrzewanie wyłączone) i listopadzie (okres grzewczy). Materiał uzyskano metodą sedymentacyjną Kocha, eksponując płytki Petriego z podłożem Sabourauda z chloramfenikolem oraz z różem bengalskim, w trzykrotnym powtórzeniu na każdym stanowisku. Ogółem uzyskano 111 izolatów grzybów drożdżopodobnych i drożdży właściwych, należących do 40 gatunków zgrupowanych w 19 rodzajach. W obu porach roku i typach badanego powietrza notowano tylko jeden gatunek –Kluyveromyces marxianus. Stwierdzono, że powietrze budynków szkolnych, o prawidłowych parametrach wilgotności i temperatury, może obfitować w grzyby drożdżopodobne – 28 gatunków drożdżaków z 15 rodzajów. W powietrzu atmosferycznym zidentyfikowano 20 gatunków z 14 rodzajów. W powietrzu wewnętrznym dominantem był Kluyveromyces lactis, natomiast w powietrzu zewnętrznym Yarrowia lipolytica, gatunek o największych zdolnościach symbiotycznych. Porównując badane siedliska zauważono, że w sensie epidemiologicznym, pomieszczenia szkolne stwarzają większe możliwości zakażeń grzybami drożdżopodonymi niż powietrze na zewnątrz budynków. Pomieszczenia intensywnie użytkowane, zwłaszcza z limitowanym dostępem światła, mają najszersze spektrum gatunkowe drożdżaków, a tym samym stanowią największe potencjalne zagrożenie dla zdrowia dzieci i pracowników szkoły. Mikobiota powietrza wewnątrz pomieszczeń i na zewnątrz ich podlega zmianom fenologicznym, chociaż jest determinowana przez inne czynniki biotyczne i abiotyczne. Do „grzybów domowych” można zaliczyć gatunki drożdżaków występujące tylko w pomieszczeniach, natomiast gatunki pochodzące z powierza atmosferycznego można uznać za „grzyby polowe”.
Źródło:
Acta Mycologica; 2009, 44, 1; 97-107
0001-625X
2353-074X
Pojawia się w:
Acta Mycologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to the airborne mould Botrytis and its health effects
Autorzy:
Jurgensen, C W
Madsen, A.M.
Powiązania:
https://bibliotekanauki.pl/articles/49724.pdf
Data publikacji:
2009
Wydawca:
Instytut Medycyny Wsi
Tematy:
healthy effect
allergy
Botrytis
fungi
indoor air
mould
occupational exposure
outdoor air
season
spore calendar
asthma
human disease
Źródło:
Annals of Agricultural and Environmental Medicine; 2009, 16, 2; 183-196
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie parametrów powietrza w kotłowni opalanej różnymi rodzajami paliwa
Parameters of air fired boiler fed with different types of fuel
Autorzy:
Gładyszewska-Fiedoruk, K.
Rybałtowska, N.
Powiązania:
https://bibliotekanauki.pl/articles/400633.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
jakość powietrza wewnętrznego
tlenek węgla
dwutlenek węgla
kotłownia
indoor air quality
carbon monoxide
carbon dioxide
boiler
Opis:
W pracy podjęto próbę analizy wyników z przeprowadzonych pomiarów CO i CO2 w kotłowniach przydomowych. Przedstawiono stężenie spalin w trakcie energetycznego wykorzystania różnych rodzajów paliwa (olej opałowy lekki, pellet drzewny, ekogroszek, drewno brzozowe z węglem). Dało to możliwość oszacowania, które z badanych paliw daje najwyższą jakość powietrza w kotłowni podczas jego spalania, a tym samym najniższe stężenia badanych parametrów. Dodatkowo pozwoliło to dowieść, które paliwo w jakich warunkach spala się całkowicie i zupełnie, co oznacza, że wszystkie składniki paliwa uległy spaleniu do postaci ostatecznej i w spalinach nie ma już palnych cząstek. Analiza kosztów pozwoliła sprawdzić, jaki nośnik energii będzie najkorzystniejszy pod względem finansowym.
The measurement and interpretation of indoor carbon dioxide CO2 concentration can provide information on building indoor air quality and ventilation. On the other hand, concentration of carbon monoxide CO can show as how combustion process run and if the boiler is safe. When there is not sufficient air available to complete the combustion process, some of the fuel is left unburned, resulting in inefficiency and undesirable emissions. An examination of the CO2 and CO concentration in boiler and interpretation results help to improve indoor air quality. The paper presents characteristics of concentration CO2 and CO depend on used fuel in tested boiler rooms. The concentration curves show how each fuel combustion affect the amount of CO2 and CO that is produced.
Źródło:
Inżynieria Ekologiczna; 2016, 49; 202-207
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Biophilic Installations for Indoor Air Quality Improvement
Wykorzystanie instalacji biofilicznych do poprawy jakości powietrza wewnętrznego
Autorzy:
Staszowska, Amelia
Powiązania:
https://bibliotekanauki.pl/articles/1811733.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
indoor air quality
biophilic installation
phytoremediation
green walls
jakość powietrza wewnętrznego
instalacje biofiliczne
fitoremediacja
zielone ściany
Opis:
This paper discusses the possibilities and limitations of using biophilic installations to improve the indoor air quality in residential and commercial spaces. Modular plant systems can provide the support or, in smaller facilities, even an alternative to the conventional indoor air purification techniques, such as filtration. The unquestionable advantage of green walls is their comprehensive influence on the indoor air quality by shaping both appropriate thermal and humidity conditions as well as the chemical air composition. However, these constructions are not mechanical systems and therefore, the effectiveness of these specific types of living air purifiers in removing gaseous pollutants and particulate matter cannot be expected to match the level of traditional systems.
W pracy omówiono możliwości i ograniczenia wykorzystania instalacji biofilicznych do poprawy jakości powietrza wewnętrznego w przestrzeniach mieszkalnych i komercyjnych. Roślinne systemy modułowe mogą stanowić wsparcie lub w mniejszych obiektach alternatywę dla konwencjonalnych technik oczyszczania powietrza wewnętrznego jakim jest filtracja. Niekwestionowaną zaletą zielonych ścian jest ich kompleksowy wpływ na jakość powietrza wewnętrznego poprzez kształtowanie zarówno odpowiednich warunków cieplno-wilgotnościowych jaki i składu chemicznego powietrza. Nie są to jednak układy mechaniczne i nie można oczekiwać, aby te swoistego rodzaju żywe oczyszczacze powietrza osiągały skuteczności w usuwaniu zanieczyszczeń gazowych i pyłowych na poziomie tradycyjnych systemów.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 716-726
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Childrens allergic diseases and microbial contamination of indoor air - a case report
Autorzy:
Kasznia-Kocot, J
Lis, D.O.
Kordys-Darmolinska, B.
Grzybowska-Chlebowczyk, U.
Wos, H.
Gorny, R.L.
Powiązania:
https://bibliotekanauki.pl/articles/51486.pdf
Data publikacji:
2007
Wydawca:
Instytut Medycyny Wsi
Tematy:
human disease
asthma
perennial rhinitis
microbial contamination
indoor air
allergy
child
bacteria
damp house
fungi
allergen
Opis:
The assessment of exposure to bioaerosols in damp houses of two children who suffered from perennial rhinitis and asthma was performed. The paper presents an approach to the complex (i.e., medical and environmental) treatment of allergic diseases.
Źródło:
Annals of Agricultural and Environmental Medicine; 2007, 14, 1
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CFD Analysis of an Innovative Wind Tower Design with Wind-Inducing Natural Ventilation Technique for Arid Climatic Conditions
Autorzy:
Obeidat, Bushra
Kamal, Hammam
Almalkawi, Amal
Powiązania:
https://bibliotekanauki.pl/articles/1839069.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wind tower
computational fluid dynamics
natural ventilation
wind pressure fluctuation
indoor air quality
passive ventilation system
Opis:
Wind towers are passive architectural elements traditionally used to ventilate buildings in the Middle East’s hot and arid regions. Some recent design initiatives in Jordan are particularly interested in using passive systems for natural ventilation. This paper focuses on an innovative wind tower design as a passive ventilation system, which will be integrated into a train station design in Aqaba, Jordan to improve the air quality in indoor spaces and reduce the cooling loads. The design uses wind-induced effects as the motivating forces to improve natural ventilation. The study optimized the wind tower and evaluated its performance using Autodesk Computational Fluid Dynamics (CFD) simulations and Grasshopper Rhino plug-ins. Airflow and distribution through the tower were analyzed using the CFD model. Grasshopper definitions were used to examine the tower efficiency in lowering the indoor air temperature. Simulations indicated the potential of the proposed wind tower to reduce the temperature by 6.164°C and supply the interior space with the required fresh air rates. This article outlines how wind towers can be used in contemporary architecture and incorporate the simulation methods to pave the way for architects to effectively validate the performance of their design proposals at the early design stage.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 86-97
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies