Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Thermography" wg kryterium: Temat


Tytuł:
Assessment of feasibility the use of infrared techniques in aviation : testing structures and aviation parts
Autorzy:
Sobieszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/243819.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
NDT
composites
sandwich composites
active thermography
passive thermography
Opis:
This paper presents the use of infrared thermography in aviation. Each of the described applications has been proved experimentally and revealed the advantages and disadvantages of the thermography method. Thermography is a discipline of research that allows observation of many phenomena, e.g. simple temperature analysis, defectoscopic tests and actions of aerodynamic. Its use in aviation is multidirectional therefore; thermography is an attractive method for research. Thermal techniques seem simple; however require extensive knowledge of infrared radiation, the areas in which this technique is used, the influence of camera parameters on its capabilities and software knowledge applied depending on the purpose. This paper undertakes the verification of temperature analysis method, which is based on the tests of whole machine assembly and its parts during their operation - widely known as passive thermography. Another raised issue is defectoscopic study which aim is to detect structural defects by non-destructive testing (NDT) - active thermography. Several types of sandwich and composite materials were selected, and on the basis of the test results the limitations and possibilities of thermography in the field of active thermography were concluded. The last application considered in this study is the use of thermography for aerodynamic testing, i.e. verification transition point, laminar to turbulent layer on the aerodynamic profile.
Źródło:
Journal of KONES; 2016, 23, 4; 479-485
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal sequences database of the skin flaps in breast reconstruction and burns
Autorzy:
Moderhak, Mateusz
Kaczmarek, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/114409.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermography
active dynamic thermography
burns
breast reconstruction
image database
Opis:
This paper presents a database of Active Dynamic Thermography (ADT) thermal sequences gathered throughout 6 year study on ADT application in skin flap blood perfusion monitoring and burn wounds diagnosis. For skin flap monitoring the database comprises of data collected during three different breast reconstruction procedures. The patients were monitored pre, intra and post surgically within 90 days period. The sequences were used in skin flap parametric imaging aimed at reducing complications and improving flap perfusion. For burns investigation patients were monitored following an accident, at the 3-rd day and 21 days after.
Źródło:
Measurement Automation Monitoring; 2019, 65, 1; 26-29
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Pulse Thermography (PT) and Step Heating (SH) Thermography in Non-Destructive Testing of Unidirectional GFRP Composites
Autorzy:
Kamińska, Paulina
Ziemkiewicz, Jarosław
Synaszko, Piotr
Dragan, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/97879.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
pulsed thermography
step-heating thermography
composites
NDT
NDE
GFRP
Opis:
This paper presents two techniques of active thermography i.e. the pulsed thermography technique and the step heating technique. The aim of this article is to compare these two techniques and present the possibilities, advantages and limitations of their use in the context of non-destructive testing of composite materials. The experimental section presents the results of tests carried out on samples of the polymer composites reinforced with glass fiber.
Źródło:
Fatigue of Aircraft Structures; 2019, 11; 87-102
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proposition of a method of determining the thermovision measurement extended uncertainty of the surface temperature of an object close to a camera lens
Autorzy:
Dziarski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/114078.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
uncertainty
thermography
metrology
Opis:
In the article the influence of selected factors occurring during thermal measurements on the uncertainty of thermovision temperature measurement is discussed. A situation in which the observed surface was close to the camera lens was measured (distance less than one meter). Based on the type B determination methodology described in the literature on the subject, a method of calculating the measurement extended uncertainty is proposed. A division of factors influencing the thermovision temperature measurement uncertainty into external factors and internal factors is also proposed. Factors associated with the conditions prevailing during the measurement, the geometry of the measurement system and the properties of the observed surface were considered external factors. Factors related to the calibration of the thermal imaging camera, the sensor matrix used and the properties of its measuring path were qualified as internal factors. The method of determining the value of the camera display at the highest and lowest value of a particular factor is discussed. The probability distribution for each of the external factors was determined. The measuring system constructed is presented. It is explained how the uncertainty shares and expanded uncertainty were determined in accordance with the method proposed.
Źródło:
Measurement Automation Monitoring; 2019, 65, 1; 7-10
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of infrared thermography to non-contact testing of varistors
Autorzy:
Galla, S.
Konczakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/220473.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermography
testing
varistors
Opis:
Testing of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors working in electronic devices as protective elements, on the basis of estimating temperature increments on varistor surfaces, registered by an infrared camera during surge resistance tests with standard voltage levels. To determine acceptable temperature increments on a tested varistor, preliminary testing was performed of P22Z1 (Littelfuse) and S07K14 (EPCOS) type varistors, working first at a constant load and presently during surge tests,. The thermographic test results were compared with measured varistor capacity values before and after tests. It was found that recording with thermography temperature increments greater than 6°C for both P22Z1 and S07K14 varistor types detects total or partial loss of varistor protective properties. The test results were confirmed by assessment of protective properties of varistors working in output circuits of low nominal voltage devices.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 677-688
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Observation using thermography of post-operative reaction after fascial manipulation®
Autorzy:
Fidut-Wrońska, J.
Chołuj, K.
Chmiel, J.
Pikto-Pitkiewicz, K.
Majcher, P.
Powiązania:
https://bibliotekanauki.pl/articles/2085037.pdf
Data publikacji:
2019
Wydawca:
Instytut Medycyny Wsi
Tematy:
fascial manipulation
thermography
inflammation
Opis:
Introduction and objective. Fascia Manipulation® is one of the methods focusing on the deep fascia. The assumption is that fascial manipulation is carried out on precisely determined points – coordination centres (cc), and on a limited area so as the friction occurring during manipulation would cause a local rise in temperature due to the inflammatory reaction. Rise in temperature influences modification in consistency of elementary matter in the manipulated area, and by the same token causing a decrease in the negative effects of fascia densification which stems from accumulation of hyaluronic acid. The purpose of the research is to prove the thesis that fascial manipulation causes local rise in temperature due to inflammatory reaction. Materials and method. For the research, 25 individuals with densification in lower limb area were qualified. They were exposed to a single, 3-minute facial manipulation®. By means of a thermal-imaging camera, changes in the temperature of the body in the examined area were evaluated. The body’s temperature evaluation was carried out 8 times: before the treatment, 5 minutes after the treatment, and, next, 6, 12, 18, 24, 36, 48 hours after the treatment. Results. The average surface temperature of the treated area before mobilization was 33.4°C. A statistically relevant increase in temperature was already observed 5 minutes after the treatment (increase of 0.5°C; p<0.001). However, the highest temperature was observed 24 hours after mobilization (increase of 2.4 °C). The difference between the first and 7 other measurements was statistically relevant (p<0.001). Conclusion. The statistically relevant increase in temperature under the influence of fascial manipulation® in the treatment area can confirm the occurrence of inflammatory reaction.
Źródło:
Annals of Agricultural and Environmental Medicine; 2019, 26, 3; 468-471
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stereoskopia w interpretacji termogramów obiektów inżynierskich
Interpretation of thermograms of constructions with use of stereoscopy
Autorzy:
Grońska, J.
Grzesik, I.
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/131304.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
termografia
stereoskopia
thermography
stereoscopy
Opis:
Termogram przedstawia rozkład temperatury na obserwowanej powierzchni, przez co znacznie się różni od obrazu w świetle widzialnym. Inną cechą szczególną termogramu są rozmycia konturów, spowodowane płynnością rozkładu temperatury na powierzchni obiektu. Utrudnia to identyfikację szczegółów na termogramie, a zatem umiejscowienie na powierzchni obiektu (zwłaszcza obiektów wielopowierzchniowych) odczytanej wartości temperatury. Dla ułatwienia interpretacji autorzy próbują zastosować wykonywanie i stereoskopową obserwację stereotermogramów. Analizę jakości modelu stereoskopowego przeprowadzono na termogramach budynków przemysłowych i mieszkalnych. Dokładność pomiaru na stereotermogramach oceniano przez porównanie go z wynikami pomiaru geodezyjnego i fotogrametrycznego. Stwierdzono, że model przestrzenny jest wyraźnie widoczny wtedy, kiedy oglądamy obrazy w małej skali. Powiększanie obrazu powodowało pogorszenie jakości obserwacji, czasami do tego stopnia, że nie można było osadzić znaczka pomiarowego na powierzchni modelu. Dokładność odtworzenia przestrzennego położenia elementów obiektu zarejestrowanego na stereotermogramie nie jest wysoka. Dla uzyskania dokładnych informacji geometrycznych o obiekcie stereotermogramy nie zastąpią steropary zdjęć fotograficznych (nawet tych wykonanych niewysokiej jakości kamerami cyfrowymi), mogą być natomiast bardzo pomocne przy interpretacji rozkładu temperatury.
Authors are proposing use of stereoscopic observation of thermograms in order to simplify their interpretation. Analysis of the quality of the stereoscopic model has been made on the images of industrial and habitable buildings. It has been found that model is clearly visible when it is seen in a low scale. Enlargement of the image resulted in decreasing accuracy of observations. Accuracy of spatial placement of objects' elements recorded on the stereograph. In order to acquire geometri-cally accurate information about the object it is necessary to make a photographical stereopair, but thermographical stereograph is very useful in the interpretation of temperature distribution.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2003, 13b; 371-377
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New opportunities for infrared thermography in medicine
Nowe możliwości zastosowania termografii w medycynie
Autorzy:
Ring, F.
Jung, A.
Żuber, J.
Powiązania:
https://bibliotekanauki.pl/articles/261638.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia
termowizja
thermography
thermovision
Opis:
In the last b50 years, termography imaging has found many applications inj medicine. Nowadays, the adventage of computer technology and image processing enable the development of thermography techniques. In this paper some new developments and historical milestones, are reviewed.
Termografia znajduje wiele zastosowań w medycynie od blisko 50 lat. Dynamiczny rozwój nowoczench technologii komputerowych oraz aparatury termowizyjnej umożliwił dalszy postęp technik termograficznych. W pracy zaprezentowano zarówno nowe, jak i już historyczne osiągnięcia.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 1; 28-30
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active Thermography in Qualitative Evaluation of Protective Materials
Autorzy:
Gralewicz, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/90338.pdf
Data publikacji:
2009
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
protective material
active thermography
defects
Opis:
This is a study of the possibilities of a qualitative evaluation of protective materials with active thermography. It presents a simulation of a periodic excitation of a multilayer composite material. Tests were conducted with lock-in thermography on Kevlar® composite consisting of 16 layers of Kevlar® fabric reinforced with formaldehyde resin with implanted delamination defects. Lock-in thermography is a versatile tool for nondestructive evaluation. It is a fast, remote and nondestructive procedure. Hence, it was used to detect delaminations in the composite structure of materials used in the production of components designed for personal protection. This method directly contributes to an improvement in safety.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2009, 15, 4; 363-371
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active dynamic thermography in mammography
Autorzy:
Kaczmarek, M.
Nowakowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1965793.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska
Tematy:
thermography
breast cancer
mathematical modelling
Opis:
We discuss limitations of the known methods of IR imaging in diagnostics of breast cancer. In conclusion we show that the known methods, based on simple observation of external temperature distribution, are not fully effective. Even advanced pattern recognition could not help in analysis of static images. May active dynamic thermography, known in non-destructive testing of materials, be of any help in breast cancer diagnostics? Analysis of thermal transients forced by external thermal excitation shows, even on simple models, that one may expect a visible improvement in resolution after such excitation. Applied models allow analysis of both static and active thermograms. Basing on the models one may recognise elements of the internal structure of a breast not visible in static pictures. This method, new in clinical practice, seems to be promising, but requires further studies.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2004, 8, 2; 259-267
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remarks on noise removal in infrared images
Autorzy:
Budzan, S.
Wyżgolik, R.
Powiązania:
https://bibliotekanauki.pl/articles/114180.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermography
infrared images
noise removal
Opis:
Noise removal in IR (Infra Red) images is very popular in recent years, however the same approach is utilized as for vision images, with no or minor changes. In this work we wanted to show the results of noise removal for selected filters. We focused on investigation of some filters normally used for image processing and their influence to IR image quality. In IR imaging the choice of filter depends mainly on the purpose of the processing, e.g. detection of small objects in complex images, edge and contour detection or removal of non-uniformity of the detector array. The performance of the selected noise reduction filters was evaluated using PSNR (Peak Signal-to-Noise Ratio) and MAE (Mean Absolute Error) quality measure, greater value of the PSNR and lower value of the MAE indicate better noise reduction. The results are shown only for few images from our database which contain over 2000 of IR images.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 187-190
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of selected thermal properties of components of bonded joint for purposes of active thermography
Autorzy:
Fidali, M.
Kruczek, T.
Kurpiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/114512.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diffusivity
specific heat
active thermography
Opis:
Adhesively bonded joints are widely used in the automotive industry. Different kinds of defects could appear in the bounded joint during its creation. The defects could be detected by use of many destructive and non-destructive methods including active thermography. Application of active thermography requires setting of test parameters. It could be done based on analytical or numerical models which requires material properties of bonded components. In the article presented results of measurements of thermal diffusivity and specific heat of automotive steel and adhesive for purposes of further modelling and estimation of active thermography test parameters.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 102-106
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Heat Transfer in Radiators for LED Light Sources Using Thermography and Numerical Modeling
Autorzy:
Szubel, M.
Basista, G.
Karkoszka, L.
Powiązania:
https://bibliotekanauki.pl/articles/114533.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
LED
radiators
thermography
numerical modelling
Opis:
Light-emitting diodes – LED, appeared on the market in the 60s of the last century, and today it is the fastest developing lighting technology. Due to high heat flux on the small surface of the individual diodes, problems related to the light source cooling become to be one of the basic ones. The paper presents results of the thermographic and numerical analyses of the chosen design of the LED lamp radiator. Experimental and computational data have been compared and discussed.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 257-260
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic monitoring of the power transformers
Autorzy:
Lisowska-Lis, A.
Powiązania:
https://bibliotekanauki.pl/articles/114168.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformer
thermography
diagnostics
monitoring
cooling
Opis:
Results of thermographic monitoring of exemplary power transformers are presented in the paper. Series of thermograms were taken. The areas on the transformer surfaces were analysed for higher temperature in aspects of: the electrical insulation condition of the transformer, the area on the surface, the season of the measurement. The thermograms indicated inefficient cooling for the transformers with deteriorated electrical insulation, especially during the summer season.
Źródło:
Measurement Automation Monitoring; 2017, 63, 4; 154-157
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Foreground extraction in images obtained in active thermography
Autorzy:
Kurpiński, M.
Jamrozik, W.
Powiązania:
https://bibliotekanauki.pl/articles/114529.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
active thermography
image processing
segmentation
Opis:
Detecting defects in adhesively bonded joints, using active thermography methods is very promising NDT testing method. In many cases, tests are made with agreed conditions, where a test object is always in specific place of IR camera view. Although, for needs of industry, system should be able to adjust Region of Interest in order to prevailing conditions. Therefore, it is necessary to develop appropriate method for this task. The paper describe one of the easiest attempt to separate foreground of an IR image sequence acquired by Lock-In Thermography (LT) and Pulse Thermography (PT). Proposed approach is based on segmentation and morphological operations. The IR image sequences of 11 various samples were used for this task. Obtained results show that elaborated technique of foreground object extraction is possible.
Źródło:
Measurement Automation Monitoring; 2017, 63, 4; 150-153
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-destructive evaluation of rescue and patrol unmanned aerial vehicle
Autorzy:
Pawluczy-Majka, J.
Powiązania:
https://bibliotekanauki.pl/articles/243854.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
UAV
NDT diagnostics
active thermography
Opis:
With the growing intensity of civil usage of the UAV, one of the most important problems is safety. It consists of operational safe use of the UAV in the common air area and reliability of the aerial vehicle construction. Each flying object is subjected to external loads, which influence on it in flight and on the ground. The external loads are mainly caused by aerodynamic, weight and inertia influence, ground reaction force and the power unit [1]. That is why during service, UAV structures are prone to many mechanical and environmental conditions that can damage to composite structures in the form of delamination, fiber breakage, and matrix cracking. Monitoring the level and type of damage to a composite structure is vital to determining the component’s structural integrity and preventing the failure of the structure during flight [2]. Non-destructive testing which has been used so far to identify defects in the aircraft structure made from metallic materials has a quite limited application in the case of composite structures. With the growing use of composites in the aviation industry, a necessity appears to work out a method allowing identification of technological defects and damages appeared in the process of the UAV’s operation. The answer to the appearing demand could be, for instance, the active thermography technique used for the thin wall test of the skin elements of the UAV. The obtained research results bring closer the problem of selection of the quick, well-fitted non-destructive testing method depending on the kind of the diagnosed construction.
Źródło:
Journal of KONES; 2014, 21, 4; 411-416
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of flow boiling heat transfer in a rectangular minichannel using liquid crystal and infrared thermography
Autorzy:
Strąk, K.
Piasecka, M.
Powiązania:
https://bibliotekanauki.pl/articles/175560.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flow boiling heat transfer
rectangular minichannel
enhanced foil surface
liquid crystal thermography
infrared thermography
Opis:
This paper presents results of flow boiling heat transfer in two parallel asymmetrically heated vertical minichannels. The heating element for Fluorinert FC-72 flowing in the minichannels was a thin foil with an enhanced surface on the side in contact with the fluid. The channels were observed from both sides through glass panes. Two of the panes allowed us to observe the two phase flow patterns on the enhanced surface of the foil, while the other two panes were used for simultaneous measurement of temperature on the smooth side of the foil. The temperature was measured by applying two contactless methods. One was liquid crystal thermography (LCT), which required treating the foil surface with thermochromic liquid crystals (TLCs), and the other was infrared thermography (IRT), which required coating the foil surface with black paint. Calculations were performed on the basis ofa one-dimensional model to determine the heat transfer coefficient at the foil-fluid interface from the Robin boundary condition. The experimental results were graphically represented as the foil temperature and the heat transfer coefficient against the distance from the minichannel inlet and as LCT and IRT images obtained for saturated boiling.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 128; 97-118
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of Bonded Joint Defects by use of Lock-in Thermography
Autorzy:
Kurpiński, M.
Fidali, M.
Powiązania:
https://bibliotekanauki.pl/articles/114547.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
lock-in thermography
NDT
bonded joints
Opis:
Joining of two or more materials using adhesives is one of the most widely used way to connect and/or seal steel panels used in the automotive industry. Due to instabilities of the technological process a different kind of defects could appear in the adhesively bonded joints. There are many destructive and non-destructive methods allowing investigation of defects of bonded joints. In this article lock-in thermography (LT) technique was used to detect of discontinuities in sealing joints between two steel plates. Results of the research shown the defect of bonded joints could be recognised effectively however it is necessary to ensure proper test conditions.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 333-336
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena aktywności wybranej grupy mięśni na podstawie pomiaru zmian temperatury powierzchni ciała
Evaluation of activity of a chosen group of muscles on the basis of temperature changes on the skins surface
Autorzy:
Anwajler, J.
Dudek, K.
Powiązania:
https://bibliotekanauki.pl/articles/261644.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia
aktywność mięśni
thermography
muscular activity
Opis:
W pracy analizowano możliwość oceny aktywności mięśni na podstawie pomiaru zmian temperatury bezpośrednio nad powierzchnią pracujących mięśni. Przedstawiono wyniki pomiaru zmian temperatury na powierzchni skóry nad grupą mięśni zginających przedramię po ćwiczeniach czynnych z oporem, wykonywanych asymetrycznie. Określono optymalne warunki rejestracji termograficznej zmian temperatury skóry nad mięśniem dwugłowym ramienia oraz zależność tych zmian od intensywności ćwiczeń.
The aim of this work was to analyse the possibility of evaluating muscular activity on the basis of temperature changes measured directly over the surface of working muscles. Temperature changes on the skin surface over the group of muscles responsible for flexing the forearm after active exercises with resistance carried out asymmetrically, were measured. The following parameters were determined: optimal conditions for thermal recording of the temperature changes of the skin's surface over the biceps muscle of forearm and the influence of the exercises intensity on temperature distribution.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 1; 20-22
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Image processing techniques for roi identification in rheumatoid arthritis patients from thermal images
Autorzy:
Wasilewska, A.
Pauk, J.
Ihnatouski, M.
Powiązania:
https://bibliotekanauki.pl/articles/386454.pdf
Data publikacji:
2018
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
dynamic thermography
image processing
segmentation
inflammation
Opis:
Rheumatoid arthritis (RA) is a systemic autoimmune disease that manifests itself by joint inflammation, swelling, pain, tenderness and may involve extra-articular organs in severe cases. Joint inflammatory lesions are associated with higher temperature due to increased vascularity in the area of inflamed tissues. This papers aimed to identify heat patterns from ROIs to interpret the presence of inflammation in rheumatoid arthritis patients. The thermovisual image sequences were collected from 65 patients with Rheumatoid Arthritis (RA). Infrared images were generated by a thermal scanning camera (FLIR E60bx Systems Inc., USA). Separate recordings of left and right foot temperature changes were performed for 3 minute periods. The temperature measurement was performed at the moment right after cold water immersion (post-cooling temperature) and at the moment after thermal recovery (post-recovery temperature). The recording of 3-minute foot thermal recovery was used for analysis. Automatically identified ROI corresponds to the area of the soft tissues covering cuboid and navicular bone.
Źródło:
Acta Mechanica et Automatica; 2018, 12, 1; 49-53
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczne zastosowanie badań termowizyjnych przez energetykę zawodową
Practical application research infrared by power industry
Autorzy:
Kowalczyk, R.
Pacholski, K.
Walczak, J.
Olbrycht, R.
Powiązania:
https://bibliotekanauki.pl/articles/267564.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
termowizja
energetyka zawodowa
thermography
power industry
Opis:
Wykorzystanie kamery termowizyjnej do oceny stanu technicznego aparatury rozdzielczej i dystrybucyjnej systemu energetycznego ma bezpośredni wpływ na zachowanie ciągłości dostaw energii elektrycznej. Szczególne warunki środowiskowe, odnoszą się bezpośrednio do sposobu interpretacji wyników pomiarów. Zaprezentowane przykłady badań termowizyjnych, obrazują mechanizmy działań stosowane w praktyce zawodowej. Uzmysławiają, że zignorowanie nawet najmniejszych nieprawidłowości może skutkować rozległą awarią systemu energetycznego. Natomiast prawidłowa weryfikacja termogramów umożliwia diagnostykę sytemu bez konieczności pozbawiania dopływu energii elektrycznej do odbiorców przemysłowych i indywidualnych.
The use of a thermal imaging cameras to analyze the technical condition of the switchgear and distribution of the energy system has a direct impact on the continuity of electricity supply. Specific environmental conditions relate directly to how to interpret the results. The presented examples of research of the thermal imaging, illustrate the mechanisms of action used in professional practice. They make clear that ignoring even the smallest irregularities may result in the failure of an extensive energy systems. Whereas the correct verification of the thermal image allows diagnostics of the system without depriving voltage transmission facilities and thus without disconnecting customers.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 55; 25-28
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrochemical capacitor temperature fluctuations during charging/discharging processes
Autorzy:
Galla, Stanisław
Szewczyk, Arkadiusz
Lentka, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/220829.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrochemical capacitor
statistical parameters
quality
thermography
Opis:
The paper presents a proposal of using additional statistical parameters such as: standard deviation, variance, maximum and minimum increases of the observed value that were determined during measurements of temperature fields created on the surface of the tested electrochemical capacitor. The measurements were carried out using thermographic methods in order to support assessment of the condition of electrochemical capacitor under classic durability tests based on methods of determination of capacity and equivalent series resistance. The possibility of using some statistical parameters in assessment of the electrochemical capacitor quality was illustrated. The applied measurement methodology and the results of research associated with the classic methods of supercapacitors’ assessment are presented. The obtained results indicate that the variability of some statistical parameters of temperature fields can be directly related to changing the values of standard parameters describing electrochemical capacitor, which are capacitance and equivalent series resistance.
Źródło:
Metrology and Measurement Systems; 2019, 26, 1; 23-35
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic evaluation of CaO additive on the process of waste hygienization
Autorzy:
Famielec, S.
Gliniak, M.
Kapjor, A.
Łukasiewicz, M.
Malinowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/101498.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
CaO
Municipal Solid Waste
hygienization
thermography
Opis:
Municipal Solid Waste (MSW) is the mixture of many waste types, including organic waste (garden and park waste, food and kitchen waste, paper and cardboard etc.). Such waste creates a living environment for various microorganism species, many of which are known as pathogenic. The presence of microorganisms in favorable conditions (pH, organic matter content, carbon content, moisture, appropriate granulation) leads to decomposing of organic matter, which is accompanied by an increase in temperature. Microorganisms in waste pose a serious risk for staff operating at waste treatment plants. Moreover, heat released by their activity may cause a fire in waste storage facilities. Therefore, it is necessary to search for methods of waste stabilization and hygienization. The most commonly applied technology for waste stabilization is its processing in Mechanical Biological Treatment (MBT) plants. Such treatment is capital – and timeconsuming, however. Waste liming can become an alternative method for stabilization and hygienization of waste. Lime addition is one of the oldest method known by humans for hygienization of certain waste materials, such as animal waste. Currently, liming is applied in sewage sludge treatment as one of the initial operations and is necessary for further sludge management processes. The aim of the research was to valuate temperature changes during mixed MSW hygienization process with CaO addition in the amount of several percent by using a thermographic camera. The reaction of CaO with waste is short and lasts no longer than 20 minutes. The maximal temperatures were reached after 65-124 seconds from the time of CaO addition. The most dynamic increase in temperature were observed up to approx. 120th second of the process, with the rate dependent on the initial moisture of the material. The observed pH values indicate that the maximal dose of CaO additive should not exceed 3%. Such a dose is sufficient for waste to reach pH 12, which, according to literature, guarantees the deactivation of microorganisms.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/4; 1857-1865
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infrared thermography as a rapid and non-invasive diagnostic tool to detect inflammatory foot diseases in dairy cows
Autorzy:
Gianesella, M.
Arfuso, F.
Fiore, E.
Giambelluca, S.
Giudice, E.
Armato, L.
Piccione, G.
Powiązania:
https://bibliotekanauki.pl/articles/2087735.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dairy cows
foot lesion
infrared thermography
Źródło:
Polish Journal of Veterinary Sciences; 2018, 21, 2; 298-305
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of training on infrared thermographic images of the forelimb and hindlimb joints of healthy racehorses
Autorzy:
Soroko, M.
Górniak, W.
Godlewska, M.
Howell, K.
Powiązania:
https://bibliotekanauki.pl/articles/16539089.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
thermography
horses
surface temperature
exercises
limbs
Opis:
The aim of this study was to evaluate the influence of training on body surface temperature over the joints in racehorses, measured by infrared thermography. The study involved monitoring of 14 Thoroughbred racehorses in 6 imaging sessions over a period of 3 months. Temperature measurements of the forelimb and hindlimb joints were made before and just after training. Joint temperature of limbs increased significantly after training. Environmental temperature had a statistically significant influence on surface temperature over the joints. The lowest surface temperatures were recorded over the metacarpophalangeal and metatarsophalangeal joint and the highest temperatures in the shoulder, elbow, hip and stifle joint. The metacarpophalangeal and metatarsophalangeal joints warmed the least during training, but were influenced the most by differences in environmental temperature. The surface temperature difference before and after training is an important indicator of the thermoregulatory response to exercise in racing horses. Understanding surface temperature changes in response to regular training is necessary for future studies on diagnosing injuries of joints.
Źródło:
Polish Journal of Veterinary Sciences; 2022, 25, 1; 83-92
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advantages of active over passive thermography in terms of applying in medicine
Zalety termografii aktywnej wobec pasywnej z punktu widzenia zastosowań w medycynie
Autorzy:
Wasilewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/270872.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
temperatura stawu
termografia aktywna
termografia pasywna
warunki chłodzenia
joint temperature
active thermography
passive thermography
cooling conditions
Opis:
Infrared thermography (IT) is a remote non-invasive technique of temperature distribution measurement and is widely applied in mechanics, electronics, metallurgy, medicine. Experimental part: 11 healthy volunteers (36% of women), mean age (28.09 (4.46)) were recruited for the study. Firstly, according to passive thermography procedure, thermographic images of left and right hand were taken. Afterwards, active thermography procedure was performed. The protocol included immersing left and right hand in ice water, separately. Results and discussion: Active thermography is to a lesser extent dependent on environmental, individual and technical factors of temperature measurement than passive thermography. Additionally, active thermography enables temperature distribution measurement over the course of time. Conclusions: Active thermography is superior to passive method.
Termografia w podczerwieni (IT) jest bezdotykową, nieinwazyjną techniką pomiaru rozkładu temperatury i jest szeroko stosowana w mechanice, elektronice, metalurgii, medycynie i innych dziedzinach. Część eksperymentalna: 11 zdrowych uczestników (36% kobiet), średni wiek (28,09 (4,46)) zostało zakwalifikowanych do badania. W pierwszej kolejności, zgodnie z procedurą termografii pasywnej, wykonano zdjęcia termowizyjne lewej i prawej dłoni. Następnie przeprowadzono procedurę termografii aktywnej. Protokół uwzględniał schłodzenie oddzielnie lewej i prawej dłoni w wodzie z lodem. Wyniki i ich dyskusja: Termografia aktywna jest w mniejszym stopniu zależna od czynników środowiskowych, indywidualnych oraz technicznych pomiaru temperatury niż metoda pasywna. Dodatkowo termografia aktywna umożliwia pomiar rozkładu temperatury w czasie.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 2; 88-93
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in selected morphological parameters and body compositio, as well as mean body surface temperature assessed by thermal imaging, in women after abdominal liposuction
Autorzy:
Chudecka, Monika
Dmytrzak, Anna
Lubkowska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1055005.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
body component
body temperature
fat
liposuction
thermography
Opis:
The aim of this study was to assess changes in selected morphological parameters and body composition, as well as in the mean body surface temperature determined by thermal imaging, in women after abdominal liposuction. As abdominal tissue edema and inflammation often persist after liposuction, body composition and surface temperatures were analyzed 3 months after surgery, during a control visit to the clinic. The 12-week delay allowed to eliminate the confounding effects of post-surgical inflammation on our results. We found a statistically significant decrease in all the analyzed morphological parameters and a change in body composition. A reduction in the subcutaneous fat tissue in the abdomen resulted in upward trends in the surface temperature of most of the analyzed areas, with a highly significant increase in the abdominal area. These studies can be considered pioneering and significant in confirming the role of subcutaneous fat as a factor regulating the body surface temperature.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2016, 14, 2; 21 - 26
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the reinforcement bars in concrete samples using eddy currents thermography
Autorzy:
Różański, Leszek
Ziopaja, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/114038.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
active IR thermography
eddy currents
reinforcement bars
Opis:
It is known that sub-surface discontinuities of matter, internal voids, inclusions of other materials or delaminations of the structure can be revealed on the surface temperature distribution. An important element of IR thermography investigations is the application of an appropriate heat source to heat the examined object. This article discusses the use of eddy currents for identification of reinforcing bars in concrete samples. The experiments have the laboratory character and are used primarily for qualitative assessment of the influence of bar diameter and concrete cover thickness on the identification of reinforcement in concrete elements. In order to induce a transient heat flow in tested samples, the eddy currents (EC) generator from IFF GmbH was used. After the pulse was completed, the surface temperature distribution was recorded using FLIR T620 infrared camera. The following experimental studies validate the practical application of active IR with EC to locate and assess the technical condition of reinforcing bars in reinforced concrete structures in buildings and civil engineering structures.
Źródło:
Measurement Automation Monitoring; 2019, 65, 2; 55-59
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of IR thermography for testing the operation parameters of water radiant ceiling systems for heating
Autorzy:
Sornek, K.
Gradzik, I.
Rzepka, K.
Filipowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/114128.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IR thermography
radiant ceiling system for heating
Opis:
This paper shows the possibility of the use of IR thermography for testing the operational parameters of water radiant ceiling systems for heating. The study showed positive results regarding the efficiency of different types of ceiling panels in a function of the level of homogeneous surface temperature distribution. Experimental results were supplemented by theoretical calculations performed with the use of a special equation originally dedicated to sun collector calculations.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 228-232
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic Criteria of Evaluation of Technical Condition of Machinery and Equipment
Autorzy:
Fidali, M.
Powiązania:
https://bibliotekanauki.pl/articles/114634.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
infrared thermography
machinery
devices
diagnostics
methodology
criteria
Opis:
Infrared thermography is used for the diagnosis purposes of various machines and devices. Despite the huge potential of thermography as a diagnostic tool, beginning thermographers are not always able to correctly assess and classify condition of the investigated object. The article presents an overview of current standards, and characterizes the methods and criteria for assessing the condition of machines and equipment.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 245-248
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-destructive evaluation of sandwich plates by an ultrasonic IR thermographic method
Autorzy:
Świderski, W.
Hłosta, P.
Chuda-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/114699.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
non-destructive testing
IR thermography
sandwich panels
Opis:
The paper presents the possibility of using an ultrasonic IR thermographic method to detect internal defects in composite types of sandwich panels with metal sheets. Experimental results indicate that this method may in many cases be effective in detecting defects that weaken the structure of sandwich panels. The results also show the limitations of using this method to sandwich panels and the materials used in them.
Źródło:
Measurement Automation Monitoring; 2016, 62, 12; 406-410
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of very thin defects in CFRP by the lock-in thermography method
Autorzy:
Świderski, W.
Powiązania:
https://bibliotekanauki.pl/articles/247348.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
non-destructive testing
composite material
IR thermography
Opis:
Quick development of constructional composite materials application is caused by their excellent mechanical and strength-related properties, combined with a low specific weight. One of the basic groups of reinforcement materials in composites are carbon fibres discovered back in 19th century. The main reason of defects in structures of composite materials is the variability of working charges in constructions during the process of using. Existed defects are complicated because of the effects like loss of continuity of reinfused fibres, binder cracks and loss of fibres adhesiveness to binder. Diagnostic methods, which are effective with relation to metals became little effective when used in detection of defects in composite materials. This caused greater interest of diagnostic techniques with using infrared thermography. Lock-in thermography is one of NDT methods providing phase images of thermal waves in a sample leading to receiving a distribution of internal defects and allowing for thermal properties evaluation. We used lock-in thermography in connection with modulated thermal source synchronized with the IR image acquisition camera. It was prepared sample of multilayer structure carbon composite with deliberately introduced defects for comparative purposes. Very thin defects of different sizes and shapes made of Teflon or copper having a thickness of 0.1 mm were searches. The results are reported in the paper.
Źródło:
Journal of KONES; 2016, 23, 1; 385-390
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody ilościowej oceny rozpoznawania ludzi na podstawie termogramów
Quantitative methods of people recognition on the basis of thermograms
Autorzy:
Owczarek, G.
Strąkowski, R.
Więcek, M.
Powiązania:
https://bibliotekanauki.pl/articles/262036.pdf
Data publikacji:
2010
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia
analiza obrazu
thermography
thermal images analysis
Opis:
W artykule zaprezentowano algorytm pozwalający na ilościową ocenę ludzi znajdujących się na zarejestrowanym obrazie, wykonanym kamerą termowizyjną. Zadaniem opracowanych modułów programowych jest wyselekcjonowanie parametrów obrazu o właściwościach dyskryminacyjnych, pozwalających wykryć człowieka. Poddano analizie: parametry statystyczne I rzędu liczone na podstawie histogramu jasności, parametry statystyczne II rzędu wyznaczone na podstawie macierzy zdarzeń wyliczonej dla czterech kierunków i trzech wielkości sąsiedztwa, parametry wyznaczone na podstawie macierzy gradientu dla maski 3 x 3 i 5 x 5, macierzy długości ciągów (run length) oraz na podstawie transformacji falkowej. Za pomocą współczynnika Fishera dokonano wyboru najlepszych parametrów charakteryzujących analizowane obrazy (o największej zdolności dyskryminacyjnej). W ten sposób wybrane cechy zostały wykorzystane do klasyfikacji termogramów za pomocą sztucznej sieci neuronowej ANN (artificial neural network).
The algorithm of quantitative evaluation of people recognition based on thermograms, is presented. The aim of the research was to select parameters of thermal image, characterized by discrimination properties, allowing the recognition of the person. The first-level static parameters obtained from luminance histogram, second-level static parameters derived from co-occurrence matrix parametrized by offset (4 directions and 3 neighborhoods), luminance
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2010, 16, 3; 276-279
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rozłożenia elementów przetwornicy ST1S10PUR na rozkład temperatury
Effect of placement of the elements of ST1S10PUR inverter on the temperature emission
Autorzy:
Ekiert, E.
Galla, S.
Powiązania:
https://bibliotekanauki.pl/articles/266426.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
power supply
thermography
layout
zasilacz
termografia
układ
Opis:
W referacie przedstawiono wpływ zmian rozłożenia elementów w przetwornicy ST1S10PUR o topologii typu Buck na emisję termiczną z układu. Wpływ był analizowany na przykładzie wprowadzania drobnych zmian w rozkładzie ścieżek mozaiki połączeń we wszystkich rozpatrywanych konfiguracjach. Zastosowane zmiany w topologii połączeń pozwalają na oszacowanie rzeczywistych parametrów przetwornicy oraz pozwalają na ocenę ich wpływu na charakterystyki emisji termicznej.
The paper presents the results of measurements performed on different thermographic system version of the DC / DC converter based on ST1S10PUR component. Based on the obtained thermograms has been estimated potential ability to use the particular solution and maximum efficiency of the ST1S10PUR has been estimated.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 40; 41-44
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zakres spektralny kamery termowizyjnej do badań w mikroelektronice
Spectral Range of IR Camera for Research in Microelectronics
Autorzy:
Błąd, G.
Wałach, T.
Powiązania:
https://bibliotekanauki.pl/articles/157693.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia
mikroelektronika
niepewność
infrared thermography
microelectronics
uncertainty
Opis:
Omówiono główne czynniki wpływające na wybór zakresu spektralnego kamery termowizyjnej do badań w mikroelektronice: parametry katalogowe kamer, przebiegi krzywych kalibracyjnych oraz własności promienne mikroukładów. Dla oceny kamer opracowano procedurę i obliczono niepewność standardową pomiaru emisyjności i temperatury. Zwykle mniejszą niepewność oferują kamery średniofalowe, lecz inne czynniki mogą zdecydować o wyborze kamery długofalowej.
In microelectronics the accuracy of infrared thermography very often depends strongly on the IR camera spectral range. Cameras with different spectral ranges are usually compared using the uncertainty of temperature measurements. There are several works devoted to calculating this uncertainty. Unfortunately, in these works the uncertainty of emissivity measurements is arbitrarily determined, which makes it difficult to evaluate generally the accuracy of cameras. In the paper procedures for calculation of the relative combined standard uncertainties of emissivity and temperature measurements are proposed. Thanks to knowledge of the definition of some camera parameters it was possible to estimate well the uncertainty components coming from the camera by using statistical relationships and to achieve a high reliability of calculations. The calculation results allow one both to evaluate generally the uncertainties for IR cameras with various spectral ranges and to determine the conditions of obtaining low values of these uncertainties. The camera calibration curve shape influences not only the uncertainty but also the result of averaging temperatures in the camera ground instantaneous field-of-view. The dependence of this result on the spectral range is analysed in the work. In microelectronics the radiative properties of the components may often have the main influence on the choice of camera. Some of these properties and their impact on measurements are also discussed.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 878-881
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wizualizacja danych pomiarowych na obiektach 3D jako sposób szybkiej i efektywnej oceny stanu urządzeń
Visualization of measurement data on 3D objects as a means of rapid and effective assessment of the equipment
Autorzy:
Gasz, R.
Powiązania:
https://bibliotekanauki.pl/articles/276317.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
termowizja
mapowanie
diagnostyka
CAD
thermography
mapping
diagnostics
Opis:
Wizualizacja danych pomiarowych, zebranych w wyniku badania temperatury obiektów, była przyczynkiem do stworzenia doskonałego narzędzia do przeprowadzania wstępnej analizy stanu urządzeń na podstawie rozkładu temperatury. W artykule przedstawiono sposób wykorzystania mapowania termogramów na obiektach 3D w celu wizualizacji rozkładu temperatury.
The article presents how to use thermal image mapping on 3D objects. With the visualization of measurement data obtained from the temperature study of objects, obtained a good tool to carry out an initial analysis of the devices based on the temperature distribution.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 3; 112-115
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic evaluation of experimental pleurisy induced by carrageenan and modified by 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD)
Autorzy:
Kuropka, Piotr
Dobrzyński, Maciej
Tarnowska, Małgorzata
Dymarek, Robert
Leśków, Anna
Wiglusz, Rafał J.
Powiązania:
https://bibliotekanauki.pl/articles/307203.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
termografia
zapalenie opłucnej
TCDD
thermography
pleurisy
rats
Opis:
The use of a thermal imaging camera may improve the detection of changes during inflammation process propagation in animals and humans that could be caused by numerous factors like 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). Methods: Rats were randomised and divided into two groups, C group, in which experimental pleural inflammatory reaction was evoked and TCDD group, in which a single dose was applied 21 days before administration of 1% carrageenan solution. Infrared thermograms were taken with a microbolometer thermal imaging camera MobIR M8. The surface temperature distribution was measured in three randomly selected animals. Results: In the analysis of correlation we found negative results between both groups. In the C group, the pleurisy was developed and allowed to develop freely. It can be observed that both the average maximum temperature and the average minimum temperature were the highest after 48 hours after injection of the 1% carrageenan in solution. In TCDD group, lowered temperature in all days of experiments was noted. However, the increase of temperature after carrageenan injection was similar. The main changes observed in the lungs were oedema, hyperemia with clot formation and changes in lung structure. Several proliferative changes in the lungs were noted. Moreover, increased number of goblet cells as well and increased release of the surfactant was observed. The activation of fibroblasts and synthesis of collagen fibers was noted. Conclusions: The TCDD administration results in the reduction of superficial temperature, which is easily detectable by thermal imaging camera that can be effectively used in monitoring the course of inflammation.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 23-29
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie termografii w diagnostyce i badaniach urządzeń elektronicznych
Application of infrared thermography to diagnosis and testing of electronic equipment
Autorzy:
Galla, S.
Konczakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/153494.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
odporność
diagnostyka
EMC
thermography
immunity
diagnostic
Opis:
Zaproponowano zastosowanie techniki termowizyjnej do oceny poprawność konstrukcji i działania urządzeń elektronicznych. Technikę termowizyjną zastosowano do badania elementów ochronnych zasilacza AC/DC w czasie standardowych badań odporności na udary oraz do badania modułów GSM pracujących pod kontrolą nadrzędnego programu sterującego i płyty głównej centrali systemu przeciwpożarowego. Pomiary termowizyjne zastosowano do oceny przyrostu temperatury ww. urządzeń.
In the paper there is proposed use of infrared thermography for assessing the validity of construction and operation of electronic devices. The most important advantages of this technique are the short time of studies and the ability of direct evaluation of results. It was found that for electronic devices it was appropriate to record infrared imagings in various states of their operation. Comparison of temperature increments from different states of operation enables validation of constructions from the heat discharge point of view. Investigations were performed for AC/DC power supplies, a GSM module, and the motherboard of a fire-fighting system using the camera VIGOcam v50. For AC/DC power supplies (Fig. 1) it was proposed to record infrared imagings during the surge immunity test (the standard EN 61000-4-5) in order to evaluate the quality of protective elements, varistors. From the imaging of the power supply immediately after the first surge (Fig. 2b) it was possible to evaluate the temperature increment on the varistor. It was stated that the accepted temperature increments on the varistor could be equal up to 30°C. The research results for the GSM module (Fig. 3) and the motherboard of the fire-fighting system (Figs. 4 and 5) are presented as imagings of the devices operating in a standby regime and with a full power. The areas with increased emission were identified. It was found that infrared thermography is very useful in the assessment of temperature distributions.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 4, 4; 345-348
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość diagnozowania termograficznego w podczerwieni jako funkcja wymuszenia termicznego w wybranych zastosowaniach medycznych
The Quality of the Infrared Thermographic Diagnosis as Function of Thermal Stimulation in Chosen Medical Applications
Autorzy:
Trafarski, A.
Jaskólska, Z.
Różański, L.
Powiązania:
https://bibliotekanauki.pl/articles/152788.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia medyczna
termostymulacja
medical thermography
thermal stimulation
Opis:
Działanie wielu zabiegów fizykalnych stosowanych w medycynie wiąże się ze zmianami temperatury tkanek. Przeprowadzono badania dotyczące możliwości wykorzystania techniki termograficznej do oceny skuteczności zabiegu krioterapii miejscowej (kriostymulacji miejscowej) u pacjentów z reumatoidalnym zapaleniem stawów. Badanie przeprowadzono w celu określenia stopnia intensywności wymuszenia termicznego podczas zabiegów krioterapii miejscowej i czasu trwania odpowiedzi organizmu na zastosowane wymuszenie. Badanie oparto na porównaniu rozkładu temperatury na powierzchni dłoni przed, zaraz po zabiegu miejscowego nadmuchu oparami ciekłego azotu lub zimnego powietrza na dłoń oraz w pewnych okresach czasu po zabiegu. Wszystkie osoby poddane badaniu były chore na reumatoidalne zapalenie stawów, u niektórych badanych występowały również inne choroby towarzyszące. Podobne procedury wykorzystano do badania reakcji współzmienniczych związanych ze stosowaniem kremów antycellulitowych. W obydwu przypadkach można było zaobserwować podobne reakcje organizmu na zastosowane wymuszenie. Badania pozwoliły na zoptymalizowanie procedur stymulacji termicznej stosowanych w reumatologii i kosmetologii.
Many medical procedures cause the thermal changes of flesh and tissues. In the paper, the investigation on the possibilities of thermographic technique application for evaluation of the criotherapy procedure success (local criostimulation) have been described. The people with rheumathoid arthritis underwent the criogenic treatment in order to evaluate the degree of local thermal stimulation and the time of the organism response. The investigations have been based on the temperature distribution on the palm surface before the treatment with cooled air or liquid nitrogen, immediately after, and in certain time periods. The similar examination had been held in the investigations of the related variables after cellulitis treatment with creams. The organism reactions are very similar in both cases. The investigations have led to the optimization of procedures of thermal stimulation in rheumatology and cosmetology.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 437-439
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long term effect of Step Aerobics Training on skin temperature. A pilot study
Autorzy:
Zuzda, J.G.
Sillero-Quintana, M.
Dziura, J.
Latosiewicz, R.
Tungthongchai, O.
Rosenberg, E.
Powiązania:
https://bibliotekanauki.pl/articles/1918941.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Thermography
Step Aerobics Training
Skin temperature
Exercise
Opis:
The purpose of this study was to evaluate the effects of a Step Aerobics Training (SAT) on the skin temperature (Tsk) in different regions (ROI) of the anterior body surface. The study included 15 healthy volunteers of the Bialystok University of Technology (BUT) without any previous experience in SAT training. Two sets of thermograms were recorded before and immediately after exercise at the first and last sessions of a 30-weeks SAT program with a progressive intensity. The results indicate a generalized drop in body temperature immediately after exercise with ΔTsk values of -2.45ºC registered immediately after the first training and lower drops (ΔTsk = -1.69ºC) after the 30 weeks of SAT. The regions with lower values of post- vs pre-exercise Tsk were the thighs both in the first session and in the last session of the 30-weeks SAT program. The results show non-significant variations for asymmetries between the values of the contralateral ROIs in every moment of the data collection. We concluded that a 30-week SAT program resulted in significant drop of mean Tsk of evaluated body parts (ROI), being the thermal effects related with the areas more activated in the sport practice. From the thermal asymmetries perspective, the training program carried out did not generate any injury risk for the participants.
Źródło:
Progress in Health Sciences; 2020, 10(2); 65-73
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and Numerical Characterization of Thermal Bridges in Windows
Autorzy:
Smusz, Robert
Bałon, Paweł
Kiełbasa, Bartłomiej
Rejman, Edward
Bembenek, Michał
Kowalski, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2201883.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
window frames
window construction
thermal bridges
thermography
Opis:
Actions aimed at improving the energy performance of buildings increase the share of heat loss through thermal bridges and windows in a building’s energy balance. This is especially true of buildings currently under construc- tion. In addition, it is known that the correct installation of windows is one of the biggest obstacles that must be overcome in order to achieve higher energy efficiency and reduce the impact of linear thermal bridges. Therefore, the study analysed, numerically and experimentally, the energy properties of PVC window frames with improved metal stiffening profiles, which were introduced to reduce the risk of window frame deformation and reduce leakage caused by faulty installation. The value of the frame thermal transmittance coefficient and the linear heat transfer coefficients were determined numerically. The simulation results showed that filling large air spaces with insulation material allowed for the reduction of the Uf frame’s thermal transmittance coefficient by over 10%. Moreover, where the window connects with the wall, there was a reduction in the linear thermal bridges’ influence on heat losses. The reduction in the linear thermal transmittance coefficient Ψ was 9.6%, 1.0%, and 3.5% for the window sill, jamb, and lintel, respectively, compared to a frame without insulation. Moreover, experimental studies were conducted on the influence of the insulation of the PVC window frame with metal closed stiffening profiles on the linear thermal bridge located at the joint with the glass. It was found that the incidence factor Itb decreased by more than 6%. Thus, there is also a positive effect on the linear thermal bridge at the joint of the glass pane with the window frame.
Źródło:
Advances in Science and Technology. Research Journal; 2023, 17, 1; 315--331
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermography – Past, Present and Future
Termografia - przeszłość, teraźniejszość i przyszłość
Autorzy:
Clausing, T.
Powiązania:
https://bibliotekanauki.pl/articles/107740.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermography
development
thermographic camera
termografia
rozwój
kamera termograficzna
Opis:
Infrared thermography is one of the fastest growing inspection techniques nowadays. This article provides an overview of the existing equipment solutions on the market of infrared thermography. It also presents the latest announcements of new products and points the path of future development of this technology.
Termografia podczerwono to jedna z najszybciej rozwijających się dziś technik inspekcyjnych. W artykule tym przedstawiono przegląd istniejących na rynku rozwiązań sprzętowych stosowanych w termografii podczerwonej. Zaprezentowano także najnowsze zapowiedzi nowych produktów oraz przedstawiano ścieżkę przyszłego rozwoju tej technologii.
Źródło:
Badania Nieniszczące i Diagnostyka; 2016, 1-2; 49-50
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Imaging in Wound Healing Diagnostics
Autorzy:
Nowakowski, A.
Kaczmarek, M.
Moderhak, M.
Siondalski, P.
Woś, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/114068.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostics
thermal model
quantitative classification
thermography
wound healing
Opis:
Results of a project searching for objective, quantitative evaluation of postoperative wound healing in cardiosurgery are presented. We propose simple thermal models of the healing processes after cardiosurgery interventions as objective descriptors allowing classification of patients for extraction and following recovery at home or for prolonged treatment in a hospital. Classification of healing as the normal process or as a process with complications is possible based on temporal changes of proposed thermal descriptors.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 195-198
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termowizyjny celownik do broni strzeleckiej - budowa, parametry i wyniki badań
Thermal weapon sight - construction, parameters and test results
Autorzy:
Madura, H.
Sosnowski, T.
Bieszczad, G.
Piątkowski, T.
Orżanowski, T.
Firmanty, K.
Powiązania:
https://bibliotekanauki.pl/articles/236223.pdf
Data publikacji:
2009
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
celownik termowizyjny
broń strzelecka
dating Thermography
shooting weapon
Opis:
W artykule został przedstawiony celownik termowizyjny do broni strzeleckiej klasyfikowany, jako kamera III generacji. Celownik pracuje w zakresie dalekiej podczerwieni (LWIR) i zbudowany jest na bazie matrycowego mikrobolometrycznego detektora podczerwieni ze stabilizacją temperatury w układzie Peltiera. Celownik termowizyjny został zbadany laboratoryjnie (w tym badania klimatyczne i wibracyjne) i wyniki badań potwierdziły zakładane parametry taktyczno-techniczne. Celownik poddano także specjalistycznym badaniom poligonowym w Wojskowym Instytucie Technicznym Uzbrojenia, gdzie prowadzono badania strzelaniem na siedmiu typach broni od kalibru 5,56 mm do 12,7 mm.
The paper presents the thermal weapon sight, which can be classified as 3-rd generation camera. The sight operates in the LWIR range and uses microbolometer focal plane array with thermoelectric temperature stabilizer. The sight has been thoroughly tested (including environmental and vibration tests) and the result confirmed its assumed technical and tactical characteristics. The sight was also tested at Military Institute of Armament Technology, where the shooting test were performed with different weapons of calibers ranging from 5.56 mm to 12.7 mm.
Źródło:
Problemy Techniki Uzbrojenia; 2009, R. 38, z. 109; 65-73
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature increase associated with plastic deformation under dynamic compression: application to aluminium alloy AL 6082
Wzrost temperatury wywołany plastycznym odkształceniem przy dynamicznym ściskaniu – analiza stopu aluminium Al 6082
Autorzy:
Perez-Castellanos, J.-L.
Rusinek, A.
Powiązania:
https://bibliotekanauki.pl/articles/280469.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
infrared thermography
plastic strain
adiabatic heating
Hopkinson bar
Opis:
The temperature increase associated with plastic deformation of a material under loading may be measured using several techniques such as infrared thermography (IRT). The present work investigates the temperature increase at different high strain rates and initial test temperatures, using an aluminium alloy Al 6082. A Split Hopkinson Pressure Bar (SHPB) was applied to induce high strain rates to the material and an infrared camera was used to measure the temperature increase. Numerical simulations of dynamic tests were performed to calculate the temperature increase and to gain a better understanding of the process by local measurements. Thus, a detailed finite-elements model was developed to simulate the dynamic compression test. The fraction of plastic work converted into heat was estimated using the Zehnder model. Numerical results in terms of the strain rate and initial temperature effect on the material temperature increase are reported and compared with experiments.
Wzrost temperatury w materiale związany z plastycznym odkształcaniem może być rejestrowany różnymi metodami, w tym m.in. techniką termografii podczerwieni (IRT). Prezentowana praca poświęcona jest badaniom wzrostu temperatury przy różnym tempie odkształceń i temperatury początkowej próbek wykonanych ze stopu aluminium Al 6082. W eksperymentach użyto zmodyfikowanego pręta Hopkinsona do generowania szybko-zmiennych odkształceń w materiale i jednocześnie dokonywano pomiarów temperatury za pomocą kamery termowizyjnej. Przeprowadzono także symulacje numeryczne przebiegu przyrostu temperatury pozwalające na lepsze zrozumienie zachodzących procesów na podstawie lokalnych pomiarowym. W tym celu zbudowano szczegółowy model bazujący na metodzie elementów skończonych, który przeanalizowano pod kątem dynamicznego ściskania. Część pracy odkształcenia plastycznego zamienianego w ciepło oszacowano za pomocą modelu Zehndera. Wyniki obliczeń uwzględniających tempo odkształceń i temperaturę początkową na jej przyrost w badanym materiale zweryfikowano z rezultatami doświadczeń.
Źródło:
Journal of Theoretical and Applied Mechanics; 2012, 50, 2; 377-398
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic method based accelerated fatigue limit calculation for steel X5CRNI18-10 subjected to rotating bending
Autorzy:
Lipski, A.
Powiązania:
https://bibliotekanauki.pl/articles/259472.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
fatigue limit
reversed bending
IR thermography
staircase method
Opis:
The article presents an accelerated method for fatigue limit calculation which makes use of constant temperature increase rate observed in the middle time interval of specimen fatigue loading. The examination was performed on specimens prepared from drawn rods made of corrosion resistant austenitic steel X5CrNi18-10 (1.4301) subjected to rotating bending. For comparison purposes, the fatigue limit was also calculated with the aid of the Staircase method, using 30 specimens and assuming the base number of cycles equal to 10・106. Three specimens were used for accelerated examination during which their temperature was measured with the aid of the thermographic camera CEDIP Silver 420M (FLIR SC 5200). The applied loads were gradually increased until specimen damage took place. Based on the analysis of temperature changes during specimen loading, the average rate of temperature increase at successive loading stages was assessed. The obtained results were then approximated using the 2-nd order curve and its minimal value was assumed as corresponding to the fatigue limit. The performed statistic test has revealed that the fatigue limit calculated in the above way does not differ substantially from that determined using the Staircase method.
Źródło:
Polish Maritime Research; 2015, 4; 64-69
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Półprzewodnikowe źródło promieniowania IR z przestrajaną emisyjnością
Semiconductor IR source with controlled emissivity
Autorzy:
Piątkowski, T.
Polakowski, H.
Trzaskawka, P.
Piotrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/157674.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
promiennik podczerwieni
emisyjność
termowizja
IR source
emissivity
thermography
Opis:
W pracy dokonano analizy wpływu parametrów geometrycznych i optycznych planarnej diody krzemowej na jej właściwości emisyjne. Przeprowadzono analizy teoretyczne oraz dokonano pomiarów emisyjności różnicowej, weryfikujących obliczenia. Wykonano badania wpływu parametrów impulsów sterujących oraz właściwości promiennych testowanego źródła. Zbadano rozkład promieniowania w obszarze optycznie czynnym. Promienniki podczerwieni takiego typu można użyć zarówno do tworzenia sceny termalnej sterowanej elektrycznie jak do pomiarów parametrów dynamicznych kamer termowizyjnych.
The paper presents the influence of geometrical and optical parameters of a planar silicon diode on its emissive properties, especially the maximal value of differential emissivity that can be achieved at 100°C operating temperature. The theoretical analysis was performed (Figs. 1, 2) and was verified by emissivity measurements for two silicon structures, 0.3 and 0.5 mm thick, with and without an aluminum reflective layer. The pulse mode for carrier injection into p-n junction was applied. The pulse parameters as well as radiative properties of silicon structure were optimized and verified experimentally. The pulse amplitude, duration and repetition frequency were determined to obtain optimal source characteristics. The apparent temperature distribution across the active surface with and without carrier injection was measured with use of a thermal camera (Fig. 7). Due to generally promising results for a single diode, the next stage of research concerning a 4-element source (2x2 matrix) is planned. The mutual influence of adjacent diodes will be investigated and the designed control electronics will be tested.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 886-889
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie termowizji w badaniach nieniszczących i w mikroelektronice
Application of Thermography in Non Destructive Testing and microelectronics
Autorzy:
Więcek, B. [et al.]
Powiązania:
https://bibliotekanauki.pl/articles/153907.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
badania nieniszczące
mikroelektronika
nondestructive testing
thermography
microelectronics
Opis:
W niniejszym artykule przedstawiono podstawowe zagadnienia jakimi zajmuje się Zespół Termografii Komputerowej Instytutu Elektroniki PŁ. Ponieważ zastosowania termowizji są bardzo ogromne i rosną, dlatego autorzy wybrali następujące zagadnienia, które są obecnie realizowane: projektowanie interfejsów do kamer termowizyjnych i integracja systemów, projektowanie radiatorów układów scalonych VLSI, wykorzystanie własności dynamicznych rur cieplnych w chłodzeniu układów elektronicznych. Przedstawione zostały również nowe zagadnienia, którymi zajmuje się zespół, takie jak badania nieniszczące z wykorzystaniem fali cieplnej jak również chłodzenie układów elektronicznych z wykorzystaniem pompy kapilarnej.
In this article, an overview of thermography applications developed in the Institute of Electronics, Technical University of Lodz are presented. The growing interest of thermography in various field of applications is observed. In the domain of scientific investigations, thermography is successfully applied for modelling cooling systems in microelectronics, including phase change solutions. Additionally, dynamic thermography is widely used in non destructive testing in material science. Thermal wave method and pulse thermography are applied.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 11, 11; 8-12
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności identyfikacji asymetrii źródeł ciepła w obiekcie biologicznym
Accurancy evalution of the identification of heat source asymmetry in biological object model
Autorzy:
Rylski, A.
Powiązania:
https://bibliotekanauki.pl/articles/154623.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
skolioza
modelowanie numeryczne
thermography
scoliosis
numeric modeling
Opis:
W artykule opisano metodę analizy pola termicznego obiektu biologicznego do określenia różnic właściwości fizycznych jego mięśni w diagnostyce skolioz, przedstawiono wpływ dyskretyzacji zmiennych funkcji ciągłej na dokładność informacji zawartej w jej wartości chwilowej, oraz sposób jej poprawienia przez synchronizowanie kroku dyskretyzacji wartości zmiennej niezależnej z przyrostem wartości funkcji.
The article describesa method of biological object thermal field analysis for the muscle physical property difference determination in scoliosis diagnosis. Influence of the quantized independent variable of continuous function on information contained in its temporary values, as well as manner of its improvement by synchronising of the discretization step of independent variable according to function increment value are presented.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 7-8, 7-8; 32-35
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of vibrations generated by handheld household appliances on temperature changes of user hands
Autorzy:
Wojsznis, M.
Mazurek, I.
Różański, L.
Barczewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/128172.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
vibrations
thermography
household appliances
drgania
termografia
sprzęt AGD
Opis:
The paper presents an analysis of influence of vibrations generated by small hand-held household appliances on temperature changes of hands. To visualize thermal changes of operators’ hands a thermographic camera was used. During the tests values of acceleration of device handle vibrations at points of contact with operators’ hands were recorded simultaneously. It has been observed that even during short periods of work the hand temperature changes significantly. The biggest recorded change was equal to 3°C. The tests have shown that the influence of vibrations is in this case sensed more strongly particularly by fingers and a wrist. The analysis of results has shown purposefulness of pointing out synergistic influence of vibrations and thermal changes caused by commonly available appliances on a human body.
Źródło:
Vibrations in Physical Systems; 2018, 29; 1-8
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of thermography to determine the compaction of a saddle-shaped briquette produced in an innovative roller press compaction unit
Autorzy:
Bembenek, Michał
Uhryński, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2204676.pdf
Data publikacji:
2022
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
roller press
thermography
thermovision
saddle-shaped briquettes
briquetting
Opis:
The unit compacting pressure in the fine-grained material consolidation process in the roller press can reach >100 MPa and is a parameter that results, among other things, from the properties of the consolidated material and the compaction unit geometry. Achieving the right pressure during briquetting is one of the factors that guarantee the proper consolidation and quality of briquettes. The distribution of the temperature on the surface of the briquettes correlates with locally exerted pressure. The present work aimed to analyse the bri-quetting process of four fine-grained materials in a roller press equipped with saddle-shaped briquette-forming rollers based on images ob-tained from the thermography conducted immediately after their consolidation. The tests were carried out in a roller press that was equipped with forming rollers of 450-mm diameter and having a cavity with a volume of 4 cm3, as described by patent PL 222229 B1. Two mixtures of hydrated lime with 9.1 wt% and 13.0 wt% water, a mixture of scale and a mixture of electric arc furnace (EAF) dust were used for the tests. In most mixtures, the highest temperatures were achieved in the middle-upper part of the briquettes. The briquettes from the EAF dust mixture heated locally the most on the surface up to 37.7 °C. The difference between the maximum briquette temperature and the ambient temperature was 20.2 °C.
Źródło:
Acta Mechanica et Automatica; 2022, 16, 4; 340--346
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termowizja w ocenie jakości przegród budowlanych
Infrared method for the quality rating of building partitions
Autorzy:
Steidl, T.
Krause, P.
Powiązania:
https://bibliotekanauki.pl/articles/157649.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
budynek
przegrody budowlane
thermography
infrared inspections
buildings
Opis:
W artykule przedstawiono zastosowanie badań termowizyjnych w ocenie jakości cieplnej przegród budowlanych. Opisano wymagania w zakresie prowadzenia pomiarów kamerą termowizyjną w budownictwie oraz główne czynniki wpływające na otrzymywane wyniki. Na praktycznych przykładach pokazano analizę badań zestawiając wyniki pomiarów termowizyjnych z obliczeniami. Dla badanych fragmentów przegród budowlanych omówiono występujące defekty i anomalie termiczne.
In the paper principles of using the infrared thermography method in building engineering are presented. The first section contains the introduction to the topic of using thermography in building engineering. Defects of building partitions which can be detected by infrared camera are described. The second section gives a short description of the factors which influence the quality of thermo-grams. According to the authors, the main factors are: infrared camera technical parameters, keeping the rules for performing investigations, knowledge of a building structure, ability of making the computer models of building partition connections which can be used to verify the investigation results. The third section presents a short overview of the investigation procedures used for taking measurements during building diagnostics. In the fourth section a way of taking the fundamental and subsidiary measurement is given. The diagnosed defects and anomalies for all partitions and connections between them are described. Several chosen thermograms made during investigations are shown in Figs. 1, 2, 4 with description of the defects. Verification of the selected ther-mograms was performed with the computer program KOBRA. In the summary some guidelines connected with the way of presenting the results of thermal diagnostics of buildings are given.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 942-945
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic and Electrical Test of Medium Voltage Surge Arresters
Autorzy:
Lisowska-Lis, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/114064.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surge arresters
medium voltage
thermography
discharge current
cooling
Opis:
The paper presents the results of a thermal test (conducted with thermographic camera, coupled with an electrical test) of medium voltage metal–oxide surge arresters. Surge arresters (for Uc=18 kV) were tested for the leakage current and surface temperature: for 5 minutes under state 50 Hz alternating voltage 18 kV. The surface temperature of the MOAs correlates with an increase in leakage current. The result shows that the 0.6 mA AC leakage current in the medium voltage metal–oxide surge arrester (18 kV) is above the stable operating point, and the loss of electrical power is higher than the effective heat dissipation in the arrester. After 5 minutes of high voltage impact U = 18 kV, the surface temperature of the surge arrester was (4.32±0.55) K higher than the initial temperature. The IR camera can be used to detect the faults of ZnO metal–oxide surge arresters that lead to an increase in surface temperature.
Źródło:
Measurement Automation Monitoring; 2019, 65, 2; 60-63
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
IR Thermography methods on nondestructive testing of ballistic covers made of multi - layer carbon fiber
Autorzy:
Hłosta, P.
Świderski, W.
Szudrowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/244251.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
IR thermography
light armour
CFRP composite
nondestructive testing
Opis:
Presently a lot of designs of light armours are based mainly on the multilayer composite materials. Thanks to these materials it was possible to achieve highest levels of ballistic resistance of specific armour at limited weight. The weight (area density) and the performance have direct influence on the value of combat ability of equipment and soldiers. Carbon fibers are basic types of reinforcement used in composites. They have many technical applications including light ballistic covers where they are mostly used as multi-layer composite materials constituting a structure made of several interconnected layers or many layers of carbon fibers, or in combination with other materials. Light ballistic covers have usually thickness of several to 10-20 mm and potential defects occurring in them have thermo-physical properties definitely different than materials they are made of so the non-destructive tests using thermography methods may be effective in detecting these defects. The main methods of active thermographic tests are as follows [1, 2]: - Pulsed Thermography – PT, - Step Heating Thermography – SHT, - Lock-in Thermography – LT, - Vibrothermography – VT. In the paper an application of Step Heating Thermography and Vibrothermography to detection of delaminating area of CFRP composites after mechanical impacts is presented.
Źródło:
Journal of KONES; 2013, 20, 2; 167-173
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowatorskie pokrycia powierzchni ciał czarnych dla zakresu dalekiej podczerwieni
Novelty Surface Coatings for Far Infrared Spectrum Black Body Radiators
Autorzy:
Ligienza, Andrzej
Bieszczad, Grzegorz
Sosnowski, Tomasz
Bartosewicz, Bartosz
Firmanty, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2068669.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
ciało czarne
termowizja
emisyjność
black body
thermography
emissivity
Opis:
Źródła promieniowania ciała doskonale czarnego są powszechnie stosowanymi urządzeniami w dziedzinach związanych z obrazowaniem termicznym i radiometrią. Stanowią najbliższe fizyczne przybliżenie teoretycznego emitera ciała doskonale czarnego wyprowadzonego z prawa Plancka. Większość takich urządzeń jest kosztowna, a informacje o technologii ich wytwarzania, w tym o powierzchni emitera, są ograniczone. Wybrano kilka stosunkowo łatwo dostępnych powłok mających potencjalne zastosowanie w tego typu urządzeniach i zmierzono ich emisyjność. W pracy przedstawiono pomiary, które dostarczają informacji niezbędnych do określenia, czy wśród wybranych istnieją powłoki zdatne do emitowania lub powierzchnie odniesienia.
Black body radiation sources are commonly used devices in areas related to thermal imaging and radiometry. They are the closest physical approximation of theoretical black body emitter derived from the Planck’s law. Majority of such devices are costly with restricted information about their production technology, including their emitter surface. A few relatively easily accessible coatings with potential application in such devices have been chosen and their emissivity measured. The paper presents measurements that provides information necessary to determine whether there are coatings viable for black body emitter or reference surface.
Źródło:
Pomiary Automatyka Robotyka; 2021, 25, 4; 77--82
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Transmittance of IR Windows made of CaF2 within Operational Temperatures of Electric Devices
Wyznaczanie transmitancji okien transmisyjnych wykonanych z CaF2 w zakresie temperatury pracy aparatów elektrycznych
Autorzy:
Dziarski, Krzysztof
Hulewicz, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/2068670.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
thermography
electric devices
metrology
termografia
urządzenia elektryczne
metrologia
Opis:
The article presents summaries of works which have resulted in the presentation of a formula making it possible to determine an approximate transmittance of an IR window used in thermographic measurements of electric device temperatures. The equation was formulated after analysing components of the IR radiation reaching the camera lens in case when an IR window was not used and when an IR window was used. Conditions prevailing in course of the thermographic temperature measurement of electric devices contained in the switchgear were recreated in the performance of the works. The measurement system which was used in the experiment has been presented. Components of the IR radiation reaching the camera lens in case when the IR window was used and when the IR window was not used have been discussed. The obtained transmittance results of windows VPFR-75 FRK100-CL have been compared against data from literary sources.
W artykule przedstawiono streszczenie prac, w wyniku których uzyskano wzór umożliwiający wyznaczenie przybliżonej transmitancji okna transmisyjnego wykorzystywanego w termograficznych pomiarach temperatur urządzeń elektrycznych. Równanie zostało sformułowane po przeanalizowaniu składowych promieniowania podczerwonego docierającego do obiektywu kamery w przypadku, gdy nie zastosowano okna transmisyjnego oraz w przypadku, gdy zastosowano okno transmisyjne. W trakcie wykonywania prac odtworzono warunki panujące podczas termograficznego pomiaru temperatury urządzeń elektrycznych znajdujących się w rozdzielnicy. Przedstawiono system pomiarowy zastosowany w eksperymencie. Omówiono składowe promieniowania podczerwonego docierającego do obiektywu kamery w przypadku, gdy okno transmisyjne było używane oraz w przypadku , gdy okno transmisyjne nie zostało zastosowane. Uzyskane wyniki transmitancji okien VPFR-75 FRK100-CL porównano z danymi pochodzącymi z literatury.
Źródło:
Pomiary Automatyka Robotyka; 2021, 25, 4; 25--30
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic Emission and Infrared Thermography Study of Low Strain Tensile Behaviour of AISI 304L Stainless Steel
Autorzy:
Sapietová, Alžbeta
Raček, Marek
Dekýš, Vladimir
Sapieta, Milan
Sága, Milan
Šofer, Pavel
Powiązania:
https://bibliotekanauki.pl/articles/27313863.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission
infrared thermography
stainless steel
tensile deformation
Opis:
In-situ study of deformation behaviour and mechanisms occurring during early stages of deformation is of a great practical importance. Low stacking fault energy materials, as is the case of AISI 304L, show non-linear deformation characteristics way below the bulk yield point. Shockley partial dislocations, formation of stacking faults respectively, resulting in creation of shear bands and ε-martensite transformation are the mechanisms occurring in the low strains in the studied steel. Acoustic emission and infrared thermography have been used in this study to investigate the deformation kinetics at the low strain stages of slow strain rate tensile tests. Acoustic emission cumulative energy together with the tracking of specimen maximum temperature have been found to be very useful in-situ techniques both supplementing each other in the sense of the sensitivity to different mechanisms. Mechanical, acoustic emission and infrared thermography results are discussed in detail with respect to potential occurred mechanism.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 2; 463--468
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of thermal impedance and wavelets analysis for non-destructive testing
Autorzy:
Kopeć, M.
Kałuża, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114695.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nondestructive testing
thermography
T3Ster analysis
wavelet analysis
Opis:
This paper presents a comparison of two methods used for non-destructive testing: thermal impedance (Zth) and wavelet transform (WT). The transient heating process of a textolite plate with defects was measured using a thermographic camera. Based on the measurement results, a qualitative and quantitative assessment of material structure was performed. The measured parameters describing the geometry of the tested material were temperature, time constant, angular frequency and phase. The presented results of thermographic measurements and their analysis indicate the possibility of detection of subsurface defects using both presented methods. The convergence and the correlation between results obtained using thermal impedance and wavelet methods are presented.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 223-227
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termografia w diagnozowaniu zmian zapalnych jamy ustnej
Thermography in the diagnosis of inflammatory changes of the oral cavity
Autorzy:
Rajba, S.
Pomorska-Oleś, E.
Powiązania:
https://bibliotekanauki.pl/articles/115302.pdf
Data publikacji:
2016
Wydawca:
Wyższa Szkoła Techniczna w Katowicach
Tematy:
termografia
diagnostyka stanów zapalnych
thermography
diagnosis of inflammatory conditions
Opis:
W pracy przedstawiono analizę możliwości wykorzystania kamer termowizyjnych w diagnozowaniu stanów zapalnych jamy ustnej. Przedstawiono wyniki badań dotyczące możliwości wykorzystania termografii w diagnostyce stomatologicznej oraz wnioski dotyczące implementacji termowizji i kierunki dalszych badań.
The paper presents an analysis of the possibilities of using thermal imaging cameras in the diagnosis of inflammatory conditions of the oral cavity. The results of studies on the possible use of thermography in the diagnosis of dental and proposals for the implementation of thermography and directions for further.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach; 2016, 8; 201-208
2082-7016
2450-5552
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statystyczna ocena danych w badaniach nieniszczących materiałów kompozytowych metodami termografii w podczerwieni
Statistical evaluation of data in nondestructive testing of composite materials by IR thermography methods
Autorzy:
Świderski, W.
Vavilov, V.
Powiązania:
https://bibliotekanauki.pl/articles/235868.pdf
Data publikacji:
2009
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
termografia w podczerwieni
ocena statystyczna
infrared thermography
statistical evaluation
Opis:
W artykule przedstawiono statystyczne kryteria zwiększające efektywność wykrywania defektów w badaniach nieniszczących materiałów kompozytowych z zastosowaniem metod termografii w podczerwieni, tworzenia map defektów i rozpoznawania obrazów. Przeanalizowano również wpływ szumów i zakłóceń na wyniki tych badań. Przedstawiono szereg przykładowych wyników badań eksperymentalnych ilustrujących analizowane zagadnienia.
Statistical criteria improving effectiveness of detection of defects in nondestructive testing of composite materials by IR thermography methods and creating defect maps and recognition of pictures are presented in the paper. The influence of noises and disturbances on results of these testing was analyzed. Some exemplary results of experimental tests are also presented to illustrate presented problems.
Źródło:
Problemy Techniki Uzbrojenia; 2009, R. 38, z. 112; 59-73
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody i techniki termografii w podczerwieni w badaniach nieniszczących materiałów kompozytowych
Nondestructive testing methods and techniques of composite materials by IR thermography
Autorzy:
Świderski, W.
Powiązania:
https://bibliotekanauki.pl/articles/235870.pdf
Data publikacji:
2009
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
termografia w podczerwieni
materiały kompozytowe
infrared thermography
composite materials
Opis:
W artykule, na podstawie prac naukowo-badawczych autora oraz danych literaturowych, przedstawiono stosowane metody i techniki termografii w podczerwieni w badaniach nieniszczących materiałów kompozytowych. Podano ich możliwości, zalety oraz ograniczenia wynikające zarówno z fizyki wykorzystywanych zjawisk, struktury badanych obiektów jak i stosowanej aparatury pomiarowej.
Nondestructive testing methods and techniques of composite materials by IR thermography on basis of scientific and research works of author as well as literature data are presented in the paper. Their possibilities and advatages as well as limitations resulting both with used phisics phenomena and structure od testing objects and used measuring apparatus are presented too.
Źródło:
Problemy Techniki Uzbrojenia; 2009, R. 38, z. 112; 75-92
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aramid composites after fragment-proof test by ultrasonic ir thermography
Autorzy:
Pracht, M.
Świderski, W.
Powiązania:
https://bibliotekanauki.pl/articles/245923.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
ultrasonic IR thermography
composite material
aramid fabrics
ballistic protection
Opis:
Modern soft ballistic armour is composed of high-strength fibres often used as packages of loose fabrics or laminates. These fibres include carbon, glass fibres, polymer fibres including aramid fibres and polyethylene fibres. Soft armour is applied to provide ballistic protection typically against the impact of small arms projectiles and fragments. In order to determine the level of ballistic protection for ballistic armour, fragment-simulating projectiles (FSP) are used which simulate the properties of fragments created during the explosion of various types of grenades and projectiles. The above-mentioned composites can include a variety of defects such as manufacturing defects, moisture ingress, projectiles impact and other defects. Infrared thermography is a method, which can be used to non-destructive testing and detecting defects of this type of material. However, ultrasonic stimulation is one of method of thermal stimulation used for detection defects in composite. The article presents the results of experimental research of multilayer aramid composite after fragment-proof tests by ultrasonic IR thermography method.
Źródło:
Journal of KONES; 2017, 24, 2; 191-195
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of changes in the microstructure of a gas turbine blade with a non - destructive thermographic method
Autorzy:
Kułaszka, A.
Błachnio, J.
Zasada, D.
Jóźwik, P.
Powiązania:
https://bibliotekanauki.pl/articles/246861.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
gas turbine
blade
pulsed thermography diagnosing
health/maintenance status
Opis:
Diagnostic methods applied nowadays to examine condition of a gas turbine blade have been discussed in the Introduction section. What follows in the body of the paper is presentation of findings on the assessment of changes in the microstructure of a gas turbine blade with a non-destructive thermographic method. A laboratory experiment performed on new turbine rotor blades made of the EI 867WD alloy has been described. The experiment consisted in holding the blades at different temperatures in the exhaust-gas environment produced by an aircraft engine supplied with jet fuel. The pulsed thermography method has been used to determine and analyse the temperature distribution upon the examined area while cooling-down after the earlier uniform warming it up with a heat pulse. Diffusion and effusion of heat in the alloy have been examined. Both phenomena are determined with thermal properties and other physical properties such as size, shape, weight, structure, chemical composition, thickness of the protective coating of the blade. Examination of the microstructure of the blade material has shown the increased thickness of the coating, grain size, and in particular disadvantageous modification in the strengthening gamma' phase against temperature. Finding the relationship between parameters of thermal responses of blade materials to heat pulse against the average size of precipitates of the gamma' phase and thickness of the aluminium protective coating enables inferences on changes in the blade material's condition. With this relationship as the basis and knowing permissible changes to the microstructure one can determine the 'fit-for-use' and 'unfit-for-use' (i.e. serviceable and unserviceable) conditions of the blades. Assuming the material criterion, i.e. some disadvantageous change in the morphology of precipitates of the gamma' phase in the EI 867WD alloy under examination, the 'fit-for-use' (serviceability) thresholds for blades affected with different temperatures have been defined.
Źródło:
Journal of KONES; 2012, 19, 2; 271-281
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic evaluation of muscle activity after front crawl swimming in young men
Autorzy:
Novotny, J.
Rybarova, S.
Zacha, D.
Novotny, J. Jr.
Bernacikova, M.
Ramadan, W.
Powiązania:
https://bibliotekanauki.pl/articles/306837.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
termografia
pływanie
aktywność mięśni
infrared thermography
swimming
muscle activity
Opis:
The information about the workload on individual muscles in the course of a specific physical activity is essential for targeted prevention, early diagnosis and suitable therapy concerning their overloading and injury. The aim of this study is to evaluate temperature changes in particular skin areas in the course of front crawl swimming, caused by muscle work. Methods: Thermograms were taken of 13 students of Defense University immediately and 15 minutes after swimming 1,000 m focused on 20 regions of the skin over the selected agonists and synergists in upper extremities and body. FLUKE TiR infrared hand camera was used. Results: The results indicated the significant increase in the relative temperatures in the areas of agonists of swimmers’ movement – triceps brachii: from 0.952 to 0.997 of normalized units (nu) on the right and from 0.955 to 0.986 nu on the left. At the same time, the temperature of the muscles participating in lifting the arms above the water surface and stretching them forward – deltoids – increased as well (rear part: from 1.002 to 1.015 nu on the right and from 1.002 to 1.014 nu on the left, sides: from 1.008 to 1.023 nu on the right and from 1.011 to 1.023 nu on the left). Conclusions: In conclusion, the order of the other agonists is as follows: biceps brachii, pectoralis major muscle, and latissimus dorsi. This study provides the options for objective assessment of workload on specific muscles or muscle groups during front crawl swimming.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 4; 109-116
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie termograficznych metod pomiaru temperatury w diagnostyce termicznej obiektów i urządzeń energetycznych
Thermographical Methods of Temperature Measurements Applications inj Thermal Diagnostics of Electric Power Devices
Autorzy:
Różański, L.
Powiązania:
https://bibliotekanauki.pl/articles/151882.pdf
Data publikacji:
2004
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostyka termalna
termografia w podczerwieni
thermal diagnostics
IR thermography
Opis:
W pracy przedstawiono możliwości wykorzystania termograficznych metod pomiaru temperatury w diagnostyce termicznej obiektów i urządzeń energetycznych. Uwagę skoncentrowano na diagnostyce bazującej na termografii w podczerwieni. W skrócie omówiono metodykę badań oraz kryteria diagnostyczne stosowane w Energetyce Poznańskiej S.A. Przedstawiono własne doświadczenia związane ze stosowaniem systemów termograficznych krótkofalowych (SW) i długofalowych (LW). Wymieniono problemy badawcze, których rozwiązanie może zwiększyć efektywność diagnostyki termalnej w energetyce. Opisano stanowisko przeznaczone do okresowego wzorcowania i sprawdzania właściwości metrologicznych systemów wykorzystywanych w diagnostyce termalnej.
Possibilities applications of radiational methods of temperature measurements in thermal diagnostics of the electrical power devices have been presented. Special attention has been concentrated on IR thermography. Methods of investigations and diagnostically criterions have been shown. Own experiences connected with usage of LW and SW IR systems has been presented. A computerised measuring system intended for among others thermographs calibration and examination of metrological features of these devices has been described.
Źródło:
Pomiary Automatyka Kontrola; 2004, R. 50, nr 2, 2; 36-39
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wodorostów na podstawie pomiarów termowizyjnych
Application of infrared thermography to varistors quality evaluation
Autorzy:
Bobcow, M.
Galla, S.
Konczakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/266990.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
termografia
warystory
ocena jakości
infrared thermography
varistors
quality evaluation
Opis:
Zaproponowano zastosować temperaturę, mierzoną metodą termowizyjną, do indywidualnej oceny jakości warystorów. Badania przeprowadzono dla 20 warystorów niskonapięciowych. Wykonano pomiary parametrów elektrycznych i temperatury warystorów przed testami narażeniowymi i po 2 kolejnych cyklach narażeń. Testy narażeniowe zastosowano w celu pogorszenia jakości warystorów. Zaproponowano zasady klasyfikacji badanych warystorów do grup o wysokiej i niskiej jakości na podstawie pomiarów parametrów elektrycznych przed testami. Na podstawie porównania wyników pomiarów parametrów elektrycznych i temperatury wykonanych, przed i po testach narażeniowych, wytypowano temperaturę T warystora, mierzoną po 5 minutach samo-podgrzania, jako wartość umożliwiającą klasyfikację badanego warystora do grup jakościowych. Wartość temperatury T większa niż 40 0C wskazuje, że badany warystor jest niskiej jakości.
The use of thermography displacement (NDT - non-destructive tests) is proposed to assess the quality of individual varistor. Twenty low-voltage varistors were studied where electrical and thermal performance measurements were taken before the stress-tests (part I) and after two subsequent cycles of two-tier stress tests (part III and V, respectively). Stress-tests were used to obtain degradation of the tested varistors (part II and IV, respectively). The following electrical parameters were measured: electric resistance Rp , quality Q, dissipation factor D and leakage current Iupł. The scope of the thermographic study included measurements of the varistors’ temperature within 5 minutes after turning on the power (self-heating) and 5 minutes after turning off the power (cooling). A comparison study was conducted of the classification rules, where varistors were assigned to groups depending on their quality based on either the electrical parameters measured before the stress tests, or their temperature measurements. Varistor’s temperature T, measured after self-heating it up for 5 minutes, was selected as the borderline value on basis of which the selection to the different quality groups was conducted. The temperature T higher than 40 0C indicates that the test specimen is of average or poor quality and should not be used.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 46; 21-24
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany powierzchniowej temperatury ciała po krótkotrwałej aplikacji i usunięciu elastycznego plastra stosowanego w kinesiotapingu
The changes of the superficial body temperature after short-term application and removal of elastic tape used in kinesiotaping
Autorzy:
Konieczny, G.
Soroko, M.
Ptak, A.
Kuciel, N.
Powiązania:
https://bibliotekanauki.pl/articles/261113.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia
kinesiotaping
temperatura ciała
podrażnienie
thermography
skin temperature
irritation
Opis:
Termografia jest metodą diagnostyczną stosowaną w bezinwazyjnej rejestracji i wizualizacji rozkładu temperatur na powierzchni ciała. Dzięki termografii możliwa jest m.in. ocena przeciążeń treningowych u sportowców oraz analiza termicznej reakcji tkanek miękkich na mechaniczne odkształcanie. Celem pracy była analiza zmian powierzchniowej temperatury ciała po krótkotrwałej aplikacji i usunięciu elastycznego plastra stosowanego w kinesiotapingu. Miało to posłużyć określeniu metody usuwania plastra, która najmniej wpływa na wzrost powierzchniowej temperatury ciała. W badaniu uczestniczyło 47 osób, których średnie BMI (Body Mass Index) wyniosło 20,85 kg/m2. Pomiary wykonywano pięciokrotnie: przed aplikacją plastrów (badanie 1), zaraz po odklejeniu plastra (badanie 2), 10 sekund (badanie 3), 30 sekund (badanie 4) i 60 sekund (badanie 5) po odklejeniu plastra. W badaniach wykorzystano elastyczny plaster Kinesio Tex oraz sztywny plaster marki Omnifix. Analiza zmian rozkładu temperatury powierzchni ciała w zależności od metody usuwania plastra (metoda szybka i wolna) w większości przypadków nie wykazała istotnych statystycznie różnic. Zanotowano istotnie statystycznie niższą temperaturę badanej okolicy ciała po usunięciu plastra Kinesio Tex, w porównaniu z plastrem sztywnym.
Thermography is a noninvasive diagnostic method applied in detection and visualization of superficial body temperature distribution. It is helpful in detection of sport overloads and the analysis of thermal reaction of soft tissues on mechanical deformation. The objective of this study was to analyze the changes of superficial body temperature after short-term application and removal of elastic tape used in kinesiotaping. The analysis was performed to define a method of such tape removal which would cause the minimal increase of superficial body temperature. The study included 47 students, with mean BMI (Body Mass Index): 20,85 kg/m2. The measurements were taken 5 times: before plaster application (1st measurement), after plaster removal (2nd measurement), after: 10 seconds (3rd measurement); 30 seconds (4th measurement) and 60 seconds (5th measurement) of plaster removal. The elastic plaster Kinesio Tex and stiff Omnifix plaster, were applied. The analysis of superficial body temperatures changes, depending on applied method of plaster removal (slowly and quickly), in most cases did not reveal statistically significant differences. The examination of body surface temperature distribution revealed the statistically significant lower temperature of measured area after removal of Kinesio Tex plaster, comparing to stiff plaster.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2012, 18, 3; 182-185
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Real Time Thermal Imaging of Solid Oxide Fuel Cell
Autorzy:
Jasiński, M.
Ziewiec, K.
Wojciechowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/354907.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermography
solid oxide fuel cell
sofc
thermal imaging
infrared
Opis:
In this work, a mid infrared thermography was used to study thermal behavior of solid oxide fuel cell (SOFC) with a circular shape and a diameter of 90 mm. The emissivity of the anodic surface of the fuel cell was determined to be from 0.95 to 0.46 in the temperature range 550-1200 K and the profile and temperature distribution of the anodic surface of the unloaded cell was given. The surface temperature of the cell was determined during operation and the polarity changes from open circuit voltage (OCV) to 0.0 V. It was found that the cell self-heating effect decreases with increasing temperature of the cell.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 4; 1207-1212
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu sygnału wymuszenia energetycznego na wynik analizy częstotliwościowej w technikach termografii aktywnej
Impact of energy excitation on frequency analysis for active thermography techniques
Autorzy:
Gralewicz, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/157695.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia
impuls
periodyczne wymuszenie
thermography
impulse
periodic energy excitation
Opis:
Przedstawione w pracy wyniki dotyczą badania wpływu rodzaju sygnału wymuszenia energetycznego na wynik analizy częstotliwościowej sekwencji obrazów termograficznych oraz zestawienia wyników analiz Fouriera i falkowej dla materiałów jednorodnych termicznie. Na podstawie przeprowadzonych doświadczeń popartych modelowaniem komputerowym określono wpływ sygnału wymuszenia energetycznego periodycznego i impulsowego na wynik analizy częstotliwościowej.
Results of the excitation energy impact on frequency analysis for active thermography techniques are presented. Active thermography is a non-destructive evaluation method (NDE) in which tested items are excited with heat excitation, while infrared camera measures the changes of temperature distribution in time. Heat spreads in solid materials through diffusion which is strongly dependent on the thermal qualities of the tested material. The investigations included computer simulation and experimental tests. The analysis results of different excitation (frequency and time) for testing thermally conductive and isolative materials while using impulse and periodic energy signals are presented. The comparison between the Fourier and wavelets analysis for thermally homogeneous materials is discussed. The authors defined a parameter phase difference K? for signature defect in materials whose maximum value indicates the frequency of heat excitation. For isolative materials its value is much larger (the larger the thickness of the material, the greater the value of phase angle), while for conductive ones it is smaller, hence it is difficult to locate a defect in the material. The results of the excitation energy impact on the frequency analysis showed that periodic energy is more advantageous for isolative materials, whereas impulse energy is more useful for conductive materials.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 902-905
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the temperature field using liquid crystal thermography and analysis of two-phase flow structures in research on boiling heat transfer in a minichannel
Autorzy:
Piasecka, M.
Powiązania:
https://bibliotekanauki.pl/articles/220691.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
temperature measurement
liquid crystal thermography
measurement accuracy
void fraction
Opis:
The paper presents the application of liquid crystal thermography for temperature determination and visualisation of two phase flow images on the studied surface. Properties and applications of thermochromic liquid crystals are discussed. Liquid crystals were applied for two-dimensional detection of the temperature of the heating foil forming one of the surfaces of the minichannel along which the cooling liquid flowed. The heat flux supplied to the heating surface was altered in the investigation and it was accompanied by a change in the color distribution on the surface. The accuracy of temperature measurements on the surface with liquid crystal thermography is estimated. The method of visualisation of two-phase flow structures is described. The analysis of monochrome images of flow structures was employed to calculate the void fraction for some cross-sections. The flow structure photos were processed using Corel graphics software and binarized. The analysis of phase volumes employed Techsystem Globe software. The measurement error of void fraction is estimated.
Źródło:
Metrology and Measurement Systems; 2013, 20, 2; 205-216
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie procesu inspekcji materiałów w paśmie widzialnym i podczerwieni
Modelling the optical inspection process in the visible and infrared band
Autorzy:
Czajka, P.
Giesko, T.
Mizak, W.
Powiązania:
https://bibliotekanauki.pl/articles/257507.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
multispektralne maszynowe widzenie
termowizja pasywna
termowizja aktywna
detekcja wad
multi-spectral machine vision
passive infrared thermography
active infrared thermography
fault detection
Opis:
W artykule zaprezentowano hybrydową metodę inspekcji w paśmie widzialnym i podczerwieni. W celu eksperymentalnej weryfikacji opracowanej metody zostało wykonane stanowisko badawcze. Do kontroli wizyjnej w paśmie widzialnym został zastosowany sterownik wizyjny z monochromatyczną kamerą CCD i układem panelowych oświetlaczy LED. Do kontroli w zakresie podczerwieni została zastosowana kamera termowizyjna z układem promienników podczerwieni i płytą grzewczą. Przeprowadzono analizę obszarów modelowania procesu inspekcji, uwzględniając możliwości rekonfiguracji stanowiska, stosowane metody badawcze oraz ustawienia parametrów inspekcji. Zaprezentowano analizę wyników eksperymentów dla wytypowanych obiektów z wykorzystaniem opracowanej metody. Przedstawiono obrazy uzyskane z obu torów wizyjnych, efekt nałożenia obrazów oraz wykresy profilowe wzdłuż charakterystycznych linii na termogramach.
The article presents a hybrid optical inspection method in the visible and infrared band. The research stand was fabricated for the experimental verification of the developed method. A vision controller with a monochromatic CCD camera and a system of front LED lighting were used for optical inspection in the visible band. The thermovision camera with a system of infrared lamps and heating plate were used for inspection in the infrared band. The modelling areas of the inspection process were analysed, including features for the reconfiguration of the stand, the research methods applied, and the setting of the inspection parameters. The analysis of the results is presented for selected objects with the use of the developed method. The images from both vision channels and the effect of overlay images and profile charts along representative lines on thermal images are also presented.
Źródło:
Problemy Eksploatacji; 2012, 2; 21-35
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wymiany ciepła podczas wrzenia w przepływie FC-72 w minikanałach przy użyciu termowizji i termografii ciekłokrystalicznej
A study of flow boiling FC-72 in minichannel by using infrared thermography and liquid crystal thermography
Autorzy:
Strąk, K.
Piasecka, M.
Powiązania:
https://bibliotekanauki.pl/articles/253536.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
wymiana ciepła
termografia ciekłokrystaliczna
termowizja
przejmowanie ciepła
płyn FC-72
heat exchange
liquid crystal thermography
thermography
heat transfer
FC-72 fluid
Opis:
W artykule wyznaczono współczynnik przejmowania ciepła w badaniach wymiany ciepła podczas przepływu płynu chłodniczego FC-72 przez dwa pionowe, równoległe minikanały ogrzewane asymetrycznie. Temperaturę powierzchni grzejnej i płyty szklanej każdego z kanałów mierzono odpowiednio za pomocą dwóch bezkontaktowych metod pomiaru: termowizji (IRT) i termografii ciekłokrystalicznej (LCT). Na podstawie dostępnej literatury zaprezentowano zastosowanie obu bezstykowych metod pomiaru powierzchni temperatury w badaniach wymiany ciepła. W pracy omówiono stanowisko pomiarowe oraz pokazano uzyskane wyniki pomiarów temperatury powierzchni w formie: termogramów metod: IRT i LCT. Przedstawiono i omówiono uzyskane zależności współczynnika przejmowania ciepła w funkcji długości minikanału podczas zwiększania strumienia ciepła. Zastosowanie obu bezkontaktowych metod pomiaru temperatury pozwoliło na uzyskanie pełniejszych danych pomiarowych, dokładne wyznaczenie ilości ciepła generowanego z folii grzejnej do płyty szklanej, a w efekcie otrzymania bardziej wiarygodnych wartości lokalnego współczynnika przejmowania ciepła.
The article presented calculate heat transfer coefficient on FC-72 flow boiling heat transfer in two parallel asymmetrically heated vertical minichannels. The temperature of the heated foil and glass plate of each channel was measured by applying two methods: infrared thermography (IRT) and liquid crystal thermography (LCT). Based on the available literature demonstrates the use of both the contactless methods for measuring the surface temperature in the study heat transfer. The paper discusses the workstation and the results of the measurements are shown in graphical form as thermographs method: IRT and LCT. Presented and discussed obtained depending on the heat transfer coefficient as a function of the length of minichannel while increasing heat flux. The use of both contactless of taking measurements in the temperature field methods made it possible to obtain a more complete measurement data, accurate determination of the amount of heat generated from the heating foil to a glass plate, and as a result obtain a more reliable value of the local heat transfer coefficient.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 1449-1453, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja wad technologicznych połączeń klejonych z zastosowaniem termografii aktywnej dla potrzeb przemysłu motoryzacyjnego
Identification of technological defects of bonded joints for the automotive industry needs using active thermography
Autorzy:
Kurpiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/153429.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia impulsowa
NDT
połączenia klejone
pulse thermography
bonded joints
Opis:
W artykule skupiono się na termograficznej metodzie detekcji wad ścieżek kleju. Przeprowadzone zostały rozważania teoretyczne oraz doświadczalne (z zastosowaniem termografii aktywnej metodą impulsową) związane z przepływem ciepła w obszarach gdzie występuje ciągła warstwa kleju oraz tam gdzie występuje defekt. W rezultacie dokonano kalibracji parametrów pomiaru i potwierdzono założenia teoretyczne dla prostej próbki testowej posiadającej wyraźną nieciągłość.
A bonded joint is one of the most popular types of joints in the production process of modern cars [1, 2]. The main reason for that is its uncommonly good ownerships i.e. durability, visual and economical properties [2]. To keep this features, it is necessary to provide continuity of all joints. However, there commonly occur the defects like delamination, poor cure, cracks, porosity, voids, “kissing” bonds and discontinuity of application in the industry environment (Fig. 1). There are many NDT methods (non-destructive tests) to disallow appearing these defects in the final product. In this paper, the active thermography method of NDT is described (Fig. 2). Pulse thermography as well as the simplest active thermography method, whose main idea is shown in Fig. 3, are well-known. There were made many theoretical consideration about various configurations of layers, which could occur in bonded joints (Figs. 4 and 5, Tab. 1). To verify these considerations, there was constructed a test stand (Fig. 7) and there was prepared a sample with a broken path of glue shown in Fig. 8. The results of the experimental research confirmed that earlier calculations of differences in the velocity between sectors with and without defects (Fig. 9) were right. On the other hand, a couple of the results obtained for various heating times (Fig. 10) was helpful to choose the best time of thermal influence duration.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 12, 12; 1158-1162
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykrywanie min metodami termografii w podczerwieni
Mine detection with IR thermography methods
Autorzy:
Świderski, W.
Hłosta, P.
Powiązania:
https://bibliotekanauki.pl/articles/157246.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia w podczerwieni
mina
mikrofale
IR thermography
mine
microwaves
Opis:
Zakopane obiekty powodują zakłócenia w rozkładzie parametrów cieplnych gleby. W naturalnych warunkach wymiany ciepła mogą powstać ślady termiczne poszukiwanych obiektów na powierzchni gleby w zobrazowaniu cieplnym. Dodatkowe zastosowanie źródła mikrofalowego zwiększa prawdopodobieństwo wykrywania zakopanych obiektów metodą termografii w podczerwieni. W artykule przedstawiono zarówno wyniki symulacji komputerowej jak i badań eksperymentalnych tego zagadnienia.
Many factors limit the efficiency of buried object detection by thermal methods. Underground objects create disturbances in the distribution of thermal parameters of the soil. Natural conditions of heat exchange can create a suitable thermal image on the soil surface - in the form of a wanted trace in the thermal image. The solar energy is the main source delivering heat to the soil. The range and character of changes of the heat stream and rate of accumulation in the soil on a given day depend on three factors: atmospherical conditions, the kind of surface and the properties of thermal soil. The active IR thermography method can increase probability and accelerate the detection. This method is used as one of the methods for nondestructive testing of different materials. The problem of detecting objects buried in the soil can be treated as a special case of detecting subsurface heterogeneity of a material. The active IR thermography method requires the use of a source of thermal stimulation to heat the tested objects. A microwave source was used to increase the probability of detecting the buried objects by this method. In this paper the results of such a computer simulation and experimental testing are presented.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 897-900
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termografia w podczerwieni - błędy i niepewności
Infrared thermography - errors and uncertainties
Autorzy:
Minkina, W.
Dudzik, S.
Powiązania:
https://bibliotekanauki.pl/articles/157689.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia w podczerwieni
błędy
niepewności
infrared thermography
errors
uncertainties
Opis:
W artykule przedstawiono zarys teorii błędów i niepewności występujących podczas bezstykowego pomiaru temperatury a pomocą kamery termowizyjnej. Wskazano na różnicę pomiędzy pojęciami błędu i niepewności. Dodatkowo przeprowadzono dyskusję źródeł powstawania błędów i niepewności w tego typu pomiarach. Zaprezentowano wyniki analizy niepewności metodą Monte Carlo dla wybranych warunków pomiaru. Treść artykułu odnosi się do monografii autorów pod tytułem: "Infrared Thermography - errors and uncertainties" będącej aktualnie w druku w wydawnictwie John Wiley & Sons.
In the paper there is presented an outline of the theory of errors and uncertainties for non-contact temperature measurements with an infrared camera. The paper begins with an introduction. In this section, the model of the infrared camera measurement path is described and a difference between the error and uncertainty concept is pointed out. The next section deals with the errors of infrared thermography measurements [1, 3]. In this section an analysis of the source of errors is conducted as well [3, 4]. The exemplary results of the error analysis regarding with the emissivity errors are shown (Figs. 1-3). In Section 3 an uncertainty analysis of the infrared thermography measurements is performed [1-3, 5-12, 14]. The exemplary results of the uncertainty analysis with the Monte Carlo simulations are presented (Figs. 5, 6). These results are obtained for the commonly occurring measurement conditions. The paper ends with conclusions. In this section the quantitative conclusions from the error and uncertainty analysis are drawn. These conclusions can be very useful for thermographers taking the infrared thermography measurements in practical situations. The contents of this paper refers to the authors' monograph entitled "Infrared Thermography - errors and uncertainties", currently printed in John Wiley & Sons.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 868-873
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of inner defects in industrial pipelines using transient IR thermography
Autorzy:
Kopeć, M.
Chatzipanagiotou, P.
De Mey, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114312.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
infrared thermography
transient thermal testing
defect detection
polypropylene pipe
Opis:
A long time operation of pipelines can lead to the reduction of their wall thickness. This process is accelerated by high temperature and variable pressure of the transported medium and can finally cause mechanical failures along with leaks and danger of explosion. The aim of this paper is to present a new method for the detection of abraded walls in industrial pipelines using the time-frequency analysis. The results of transient temperature measurements are used for the calculation of the thermal time constants corresponding - as demonstrated - to the pipeline wall thickness.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 115-118
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of image analysis methods on the example of ultrasonic thermography of an aramid composite
Autorzy:
Świderski, Waldemar
Powiązania:
https://bibliotekanauki.pl/articles/244857.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
non-destructive testing
composite material
IR thermography
image analysis
Opis:
Infrared thermography using ultrasound thermal excitation of the tested material is one of the most effective methods in non-destructive testing of a multi-layer aramid composite. This type of material is very popular in the construction of light ballistic armours. Typical defects are delamination between layers of aramid fabric joined by resin. They are usually filled with air. Delamination located deep under the surface of the test generates very weak temperature signals. They are often at the level of noise. To reduce the impact of noise on the detection of a defect, special methods of image analysis (thermograms) are used. Such methods include principal component analysis and wavelet analysis. Principal Component Analysis is a relatively new procedure of statistical data treatment, which is becoming increasingly popular in non-destructive testing. Mathematically, it is often regarded as implementation of the so-called singular values decomposition technique, which allows extracting of spatial information from a matrix of source data. The wavelet analysis is an integral transform, which represents the convolution of an analysed process with a special mother function called wavelet. Wavelets are characterized by two parameters: scale and shift. The paper presents a comparison of the efficacy of these methods in the detection of defects in the multilayer composite reinforced aramid fibre.
Źródło:
Journal of KONES; 2019, 26, 2; 145-150
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of internal combustion engines of motorcycles with the use of thermal imaging methods
Autorzy:
Magdziak-Tokłowicz, M.
Skrętowicz, M.
Wróbel, R.
Sroka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/949484.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
combustion engine
thermal analysis
thermography
thermal research of motorcycles
Opis:
The internal combustion engine should be rated for the thermal loads that come from different sources. Thermal analysis is important both for design purposes and for evaluating the conditions of its use. Very good results are obtained by a combination of non-invasive measurement techniques, such as research using infrared thermal imaging techniques [3, 11]. The purpose of the study was to determine the engine thermal load by evaluating the average temperature on the outside surface of the engine at many of its points for two selected motorcycle engines with similar displacement capacities. For many reasons, such as ecology, durability, engine strength and thermal performance when heating and cooling are critical. To accomplish this task, a thermographic technique for indirect evaluation has been used, thus creating the possibility of measuring the temperature in a dynamic manner. These are accurate measurements and most importantly do not interfere with the construction of the object under investigation. The engine was tested during operation according to external and load characteristics. As a result of the work, graphs of temperature curves of heating and cooling of the tested engines were compiled. The article presents a methodology for measuring the temperature fields of outer surface engines. The collected material will be used in the future for studying the equable load on the cylinders, and as accurately as possible determine the conditions of movement such as power, revolutions, flow rates, temperatures and pressures.
Źródło:
Journal of KONES; 2017, 24, 4; 181-186
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An innovative person detection system based on thermal imaging cameras dedicate for underground belt conveyors
Autorzy:
Uth, F.
Polnik, B.
Kurpiel, W.
Kriegsch, P.
Baltes, R.
Clausen, E.
Powiązania:
https://bibliotekanauki.pl/articles/88977.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Wydział Geoinżynierii, Górnictwa i Geologii. Instytut Górnictwa
Tematy:
thermography
conveyor belt
mine
health and safety
person detection
Opis:
Within the INESI-project (Increasing Efficiency and Safety Improvement in Underground Mining Transportation Routes) long-wavelength infrared (LWIR) cameras are used for detecting persons on underground belt conveyors or within hazardous areas e.g. in front of crusher or skip vessels by the project partners KOMAG and the Institute for Advanced Mining Technologies (AMT). The test case for evaluating the performance of thermal imaging regarding these applications is the Polish Sobieski underground coal mine operated by Tauron mining company. By the development of thermal image processing algorithms, an automated detection of persons and classification of different objects was achieved. This may allow implementing smart services for person detection on underground belt conveyors as well as material characterization between coal, rock and disturbing objects on belt conveyors.
Źródło:
Mining Science; 2019, 26; 275-288
2300-9586
2353-5423
Pojawia się w:
Mining Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Infrared Thermography of Cortical Bone Grinding in Neurosurgery
Autorzy:
Babbar, Atul
Jain, Vivek
Gupta, Dheeraj
Goyal, Kapil Kumar
Prakash, Chander
Saxena, Kuldeep Kumar
Kumar, Sandeep
Bartoszuk, Marian
Powiązania:
https://bibliotekanauki.pl/articles/2201892.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
biomimetic
bone grinding
Infrared thermography
thermal analysis
surfaces
burr
Opis:
In this work, an effort has been made to determine the effect of different shape surgical burr on the thermogenesis during bone osteotomy. The abrasion during bone grinding leads to heat generation and subsequently rise in the temperature which may have adverse effects such as osteonecrosis, blood coagulation in the carotid artery, damage to sciatic nerves, and even loss of vision. So, mitigating the temperature rise during bone grinding is of paramount importance. Especially, in endoscopic endonasal approach (EEA) in which nasal passage is used for the inserting the grinding burr and reaching the target region. The miniature abrasion can significantly increase the temperature and hence leads to the thermal damage to nerves surrounding the temporal and frontal lobe. These parts of the brain controls movement, problem solving ability, behavior, personality mood, hearing, language, memory, speech, breathing, heart rate, consciousness etc. Furthermore, neurosurgeons rely on their personal surgical experience for estimating the temperature rise during grinding. However, this is much difficult for novice surgeons. Therefore, it becomes critically important to preserve the soft neural tissues and nerves amid bone grinding. To overcome these concerns, infrared thermography technique has been exploited to determine the possibility of thermogenesis during bone grinding by measuring the temperature rise and its distribution using infrared camera. All experiments have been carried at a constant set of process variables. The grinding zone is continuously flooded with the irrigating solution to remove the heat and bone debris away from the grinding site. It has been observed that convex tool shape generated lower maximum temperature i.e. 46.03 ℃ among all tools. The temperature produced by the convex tool is 12.06% lower than spherical tool, 33.39% lower than cylindrical tool, and 10.55% lower than tree-shape tool. The results showed that convex shape tool could prevent thermal necrosis in the bone as temperature caused (i.e. 46 ℃) was less than the threshold limit of osteonecrosis. Thermograms revealed that infrared thermography technique could be implemented for the in-vivo surgical operations for the measurement of temperature during bone grinding.
Źródło:
Advances in Science and Technology. Research Journal; 2023, 17, 1; 116--123
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the thermographic method for the monitoring growth of selected microorganisms
Zastosowanie metody termograficznej w mikrobiologii
Autorzy:
Lipińska, E.
Pobiega, K.
Szymankiewicz, K.
Rudziak-Tałałaj, A.
Klimkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/13925563.pdf
Data publikacji:
2019
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
microorganism
thermovision
thermography
Saccharomyces cerevisiae
Aspergillus niger
Penicillium roqueforti
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2019, 599; 27-36
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of material defects using active thermography and an artificial neural network
Autorzy:
Dudzik, S.
Powiązania:
https://bibliotekanauki.pl/articles/221055.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active thermography
non-destructive testing
defect characterization
neural networks
Opis:
In the paper a method using active thermography and a neural algorithm for material defect characterization is presented. Experimental investigations are conducted with the stepped heating method, so-called time-resolved infrared radiometry, for the test specimen made of a material with low thermal diffusivity. The results of the experimental investigations were used in simulations of artificial neural networks. Simulations are performed for three datasets representing three stages of the heating process occurring in the investigated sample. In this work, the simulation research aimed to determine the accuracy of defect depth estimation with the use of the mentioned algorithm is descibed.
Źródło:
Metrology and Measurement Systems; 2013, 20, 3; 491-500
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of thermal behavior of detector array surface with the use of microscopic thermal camera
Autorzy:
Bieszczad, G.
Kastek, M.
Powiązania:
https://bibliotekanauki.pl/articles/220546.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermovision
microbolometer focal plane array
self-heating
microscopic thermography
Opis:
Modern infrared cameras are constructed with two main types of infrared detectors: photon detectors and thermal detectors. Because of economic reasons, vast numbers of modern thermal cameras are constructed with the use of infrared microbolometric detectors which belong to the group of thermal detectors. Thermal detectors detect incident infrared radiation by measuring changes of temperature on the surface of a special micro-bridge structure. Thermal detectors, like microbolometric detectors on one hand should be sensitive to changing temperature to accurately measure incoming infrared radiation from the observed scene, on the other hand there are many other phenomena that change the temperature of the detector and influence the overall response of the detector. In order to construct an accurate infrared camera, there is a need to evaluate these phenomena and quantify their influence. In the article the phenomenon of self heating due to the operation of the readout circuit is analyzed on an UL 03 19 1 detector. The theoretical analysis is compared with the results of conducted measurements. Measurements with a type SC7900VL thermographic camera were performed to measure the thermodynamic behavior of the UL 03 19 1 detector array.
Źródło:
Metrology and Measurement Systems; 2011, 18, 4; 679-690
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Characterization of High-Frequency Flyback Power Transformer
Autorzy:
Kasikowski, R.
Gołaszewski, J.
Więcek, B.
Farrer, M.
Powiązania:
https://bibliotekanauki.pl/articles/114581.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IR thermography
power losses
H-F flyback transformer
thermal impedance
Opis:
This paper presents preliminary thermographic measurements and a simple thermal analysis of power losses in high-frequency (H-F) transformers used in AC-DC power converters. The analysis is based on complex thermal impedance and time constant distribution. The main aim of this research was to consider quantitatively the contribution of different power losses in the H-F transformer, including fringing flux effect.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 237-241
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczna analiza wpływu charakterystyki wymuszenia cieplnego na wykrywanie defektów w kompozytach wielowarstwowych metodą termografii w podczerwieni
Numerical analysis of thermal stimulation characteristics influence on detection of defects in multi-layer composites by infrared thermography method
Autorzy:
Świderski, W.
Powiązania:
https://bibliotekanauki.pl/articles/235971.pdf
Data publikacji:
2016
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
symulacja komputerowa
kompozyt
termografia impulsowa
computer simulation
composite
pulse thermography
Opis:
W artykule przedstawiono wybrane wyniki numerycznych obliczeń wpływu charakterystyki wymuszenia cieplnego użytego w aktywnej metodzie termografii w podczerwieni na wykrywanie cienkich defektów w kompozytach. Obliczenia przeprowadzono dla wielowarstwowego kompozytu z tworzywa wzmacnianego włóknem węglowym. Symulacje komputerowe przeprowadzono dla typowych wymuszeń cieplnych generowanych przez lampy grzewcze. Przeanalizowano możliwości wykrywania defektów zarówno metodą odbiciową jak i transmisyjną.
Some results of numerical calculations evaluating the influence of characteristic of thermal stimulation used in active infrared thermography on detection of thin defects in composites are presented in the paper. The calculations were carried out for multi-layer composite material strengthened by carbon fibre. Computer simulations were performed for typical thermal stimulations generated by heating lamps. The possibilities for detection of defects by using both reflection and transmission methods were analysed.
Źródło:
Problemy Techniki Uzbrojenia; 2016, 45, 140; 7-20
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Postępy obrazwania termicznego w medycynie – praca poświęcona osobie profesora Antoniego Nowakoweskiego
Advances of infrared thermal imaging in medicine – devoted to profesor Antoni Nowakowski
Autorzy:
Bauer, J.
Powiązania:
https://bibliotekanauki.pl/articles/262119.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia medyczna
132. Seminarium MCB
medical thermography
132. ICB Seminar
Opis:
Praca stanowi skrótowy przegląd wiedzy na temat historii oraz najnowszych osiągnięć termografii medycznej. Przesłanką do napisania niniejszej pracy stało się 132. Seminarium Międzynarodowego Centrum Biocybernetyki, które odbyło się na przełomie czerwca i lipca 2013 i było okazją do integracji oraz do wymiany poglądów międzynarodowych i krajowych środowisk naukowych, zajmujących się medycznymi zastosowaniami termografii. Inicjatorem i przewodniczącym Seminarium Advances of Infrared Thermal Imaging in Medicine był Profesor Antoni Nowakowski z Politechniki Gdańskiej.
This review presents briefly the history and current advances of thermal imaging in medicine. The reason to write it, it was the 132. Seminar of the International Center of Biocybernetics held in Warsaw from 30 June to 3 July 2013. The Seminar devoted to Advances of Infrared Thermal Imaging in Medicine was initiated and chaired by Professor Antoni Nowakowski from Gdańsk University of Technology.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2013, 19, 3; 140-147
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termowizja jako narzędzie w diagnostyce uszkodzeń nadwozi izotermicznych i chłodniczych
Thermography as a tool in the diagnosis of body damage mechanical isotherm and refrigerating
Autorzy:
Rochatka, T.
Powiązania:
https://bibliotekanauki.pl/articles/313610.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
termowizja
diagnostyka uszkodzeń
nadwozie chłodnicze
thermography
fault diagnosis
refrigeration body
Opis:
W artykule przedstawiono opis mechanizmów uszkodzeń nadwozi izotermicznych i chłodniczych przeznaczonych do transportu żywności łatwopsującej się w stanie schłodzonym lub głęboko zamrożonym. Identyfikację uszkodzeń zrealizowano za pomocą kamery termowizyjnej w laboratorium badania nadwozi chłodniczych ATP na Politechnice Poznańskiej.
The article presents a description of mechanisms of damage to isothermal and refrigerated bodies designed to transport frozen or refrigerated frozen foods. Identification of defects was done using a thermal imaging camera ATP refrigerated body testing laboratory at Poznan University of Technology.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 1267-1270, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of thermography in engineering measurements
Autorzy:
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/225027.pdf
Data publikacji:
2007
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
termografia
pomiary inżynieryjne
pomiary geodezyjne
thermography
engineering measurements
engineering surveying
Opis:
- Existing thermographic equipment provides tools for quick and accurate recording of temperature distribution on object surfaces. - Usage of image analysis methods commonly used for photogrammetry and remote sensing provides tools for making accurate maps of temperature distribution on chosen, characteristic surfaces. - Documentation of thermal condition of new buildings should be a mandatory part of the post-construction documentation. - Real-world thermal resistance of buildings should be a factor during assertion of fulfilment of the architectural project and during valuation of buildings.
Źródło:
Reports on Geodesy; 2007, z. 1/82; 409-416
0867-3179
Pojawia się w:
Reports on Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nondestructive Testing of Ceramic Hip Joint Implants with Laser Spot Thermography
Autorzy:
Roemer, J.
Pieczonka, L.
Juszczyk, M.
Uhl, T.
Powiązania:
https://bibliotekanauki.pl/articles/356189.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
laser spot thermography
damage detection
ceramic materials
hip joint implants
Opis:
The paper presents an application of laser spot thermography for damage detection in ceramic samples with surface breaking cracks. The measurement technique is an active thermographic approach based on an external heat delivery to a test sample, by means of a laser pulse, and signal acquisition by an infrared camera. Damage detection is based on the analysis of surface temperature distribution near the exciting laser spot. The technique is nondestructive, non-contact and allows for full-field measurements. Surface breaking cracks are a very common type of damage in ceramic materials that are introduced in the manufacturing process or during the service period. This paper briefly discusses theoretical background of laser spot thermography, describes the experimental test rig and signal processing methods involved. Damage detection results obtained with laser spot thermography are compared with reference measurements obtained with vibrothermography. This is a different modality of active thermography, that has been previously proven effective for this type of damage. We demonstrate that both measurement techniques can be effectively used for damage detection and quality control applications of ceramic materials.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 4; 2133-2139
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza powierzchniowego rozkładu temperatur dolnych partii kończyn u młodych koni wyścigowych
Analysis of superficial temperature distribution of lower part of young race horse limbs
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/154648.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia
analiza temperatury
zapalenie
konie
thermography
temperature analysis
inflammation
horses
Opis:
Celem pracy było wykrycie wczesnych zmian patologicznych związanych z intensywnym treningiem koni rasy półkrwi oraz arabów z zastosowaniem badań termograficznych. Badania obejmowały 20 koni wyścigowych w wieku 3 lat przez okres 4- 6 miesięcy w odstępach 3 tygodniowych. Wyniki pomiarów analizowano za pomocą testu t-Studenta. Rozpatrywane poziomy istotności to: p<0,05, p <0,01, p< 0,001. Zastosowana metoda porównywania średnich wartości temperatur mierzonych w czasie badawczym pozwoliła na wykrycie schorzeń w przypadku ich obustronnego wystąpienia w symetrycznych obszarach ciała. i przyśpieszyła około 4 tygodni identyfikację potencjalnych stanów patologicznych, przed wystąpieniem oznak klinczach.
Objective: The objective of the study was to predict subclinical signs of pathology inflammation associated with intensive training of young Polish Halfbred and Arabian race horses during training cycle applying temperature analysis of lower part of front limbs. Materials and Methods: The study was based on 20 flat race horses at age of 3 years. Thermographic images of lower part of front limbs from cranial view were taken every third week for 4- 6 months. The symmetrical areas of the lower part of the limb were identified and analyzed for average temperature differences for each horse during the research cycle. The results were analyzed using the Student's t-test. The level of significance was determined as (0,05), great significant (0,01), most significant (0,001). Results: In case of 1 horse area of the right metacarpal bone had statistically increased temperature, indicating subclinical stages of inflammation. The remaining 3 horses demonstrated subclinical signs of inflammation in the area of the right and left metacarpal bone indicating early stages of inflammation process. Summary: Theapplied method of comparing the average temperature values of symmetrical areas, monitored during the research cycle allowed detection abnormalities also in case of their bilateral accrue of symmetrical areas. Thermography assessment accelerated identification of subclinical signs of inflammation, about 4 weeks before clinical signs occurred. This study proved that infra-red diagnosis was useful in detection of pathology when images were taken regularly within a specified period of time and that they were properly interpreted. It will help in protection and identification of lower limb pathology.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1157-1160
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termograficzne pomiary okładzin ciernych hamulców
Thermographics measurements of brake pad lining
Autorzy:
Piątkowski, T.
Polakowski, H.
Jachimowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/155824.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tarcie
parametry cieplne
termografia
emisyjność
friction
thermal parameters
thermography
emissivity
Opis:
Opracowanie nowej generacji hamulców wymaga wykonania pomiarów rozkładów temperatury na powierzchniach jego elementów konstrukcyjnych. W pracy przedstawiono wybrane wyniki takich badań metodami termograficznymi. W rezultacie tych badań określono obszary o podwyższonej temperaturze, temperaturę maksymalną oraz szybkość zmian temperatury. Porównano otrzymane wyniki z pomiarami metodą stykową. Dane otrzymane w wyniku analizy termogramów pozwolą na weryfikację modelu numerycznego hamulca.
Braking process has rather short duration (5s÷15s) and during that time the kinetic energy of a vehicle is transformed into heat. Such amount of heat generates thermal shock to braking pads and discs. Development of a new type of brakes requires measuring temperature distributions on their working surfaces. The paper presents some selected results of such measurements performed on a modified IL-68 test rig by means of thermal imaging (Fig. 2). Two types of composite braking pad materials were tested: C/C and 500/EBC. C/C composite is used for aircraft brakes, whereas 500/EBC type is used for brakes of all-terrain ground vehicles. Due to high dynamics of the thermal signal, the measurements were taken in the range from 200?C to 750?C. The data from the thermal images were processed using IR Control software. As a result there were identified the high temperature areas (hot spots), maximum temperature values for each recorded frame and the rate of temperature changes during braking (Fig. 5) as well as cooling down (Fig. 6) phases. The frame-by-frame analysis of the recorded thermal image sequences made it possible to correlate the temperature distribution non-uniformity with structural defects of the tested brake pads. The results of temperature measurements were compared with those obtained from the contact method (Fig. 7). On that basis, the errors of non-contact temperature measurements were estimated. The analysis of the recorded thermal images allowed calculating several thermal parameters, such as thermal time constants of particular brake elements (1), (2). Those data were used to verify the numerical model of the brake. They also can be the guidelines to optimise the brake design with respect to heat transfer aspects.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1285-1288
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary termowizyjne w systemach diagnostycznych
Infrared measurement technology in diagnostic systems
Autorzy:
TWARÓG, Bogusław
GOMÓŁKA, Zbigniew
KWIATKOWSKI, Bogdan
Powiązania:
https://bibliotekanauki.pl/articles/456448.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Rzeszowski
Tematy:
podczerwień
termowizja
emisyjność
diagnostyka systemów
infrared
thermography
emissivity
diagnostics systems
Opis:
W pracy zaprezentowano ideę pomiarów termowizyjnych polegających na rejestrowaniu natężenia promieniowania cieplnego emitowanego przez ciała o temperaturze wyższej od zera bezwzględnego. Do tego celu wykorzystano kamerę termowizyjną typu FLIR T620 jako analizator w wybranych zastosowaniach. Stanowisko pomiarowe prezentowane w pracy znajduje się w Centrum CIiTWTP Uniwersytetu Rzeszowskiego
The paper presents the idea of infrared measurements involving the recording of the intensity of thermal radiation emitted by a body with a temperature above absolute zero. For this purpose the type of infrared camera FLIR T620 as an analyzer for several applications has been presented. Described device stands one of the scientific laboratories equipment of CIiTWTP Center at the University of Rzeszow.
Źródło:
Edukacja-Technika-Informatyka; 2014, 5, 1; 598-604
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of patch tests results–research and development of technique based on infrared thermography
Ocena wyników testów płatkowych–badanie i rozwijanie metody opartej na termografii
Autorzy:
Szwedo, M.
Tomaka, B.
Powiązania:
https://bibliotekanauki.pl/articles/327152.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
medical thermography
allergology
image analysis
termografia medyczna
alergologia
analiza obrazów
Opis:
Skin tests in allergology are a method of medical diagnosis that attempts to provoke a small, controlled allergic response. Evaluation of the patch test depends on visual assessment so it is not an objective method, because it does concern only skin surface and difficulties like changes in skin pigmentation, atopic skin, black race skin or delayed reaction may occur. Studies with use of thermography confirm that skin surface allergic reaction is strictly connected with temperature increasing at that area so such technique may be the key for impartial evaluation. Carried out tests, also confirmed information from literature review, that to obtain valuable infrared images large intervals between allergens must be kept.
Testy skórne w alergologii to metoda diagnostyczna polegająca na wywołaniu małej, kontrolowanej reakcji alergicznej. Ocena testów płatkowych oparta jest na ocenie wizualnej, której podlega tylko powierzchni skóry, a więc nie jest obiektywna, gdyż mogą mieć na nią wpływ takie czynniki jak zmiany w pigmentacji skóry, skóra atopowa, skóra rasy czarnej lub opóźniona reakcja. Badania z użyciem termografii potwierdziły, że reakcja alergiczna powierzchni skóry jest ściśle powiązana ze wzrostem temperatury w tym obszarze, więc technika ta może być kluczowa w dążeniu do obiektywnej oceny. Przeprowadzone badania potwierdziły także informację z przeglądu literatury, że aby otrzymać wartościowe termogramy należy zachować duże odstępy pomiędzy aplikowanymi alergenami.
Źródło:
Diagnostyka; 2015, 16, 3; 3-8
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania efektów cieplnych w czasie polimeryzacji stomatologicznych materiałów do wypełnień ubytków
Evaluation of thermal effects during polymerization of restorative dental materials
Autorzy:
Dąbrowski, M.
Dulski, R.
Zaborowski, P.
Żmuda, S.
Powiązania:
https://bibliotekanauki.pl/articles/154106.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
lampy polimeryzacyjne
materiały stomatologiczne
termografia
polymerization lamps
dental materials
thermography
Opis:
W artykule przedstawiono wyniki badań dynamiki zmian temperatury podczas polimeryzacji stomatologicznych materiałów do wypełnień z użyciem lamp polimeryzacyjnych. W badaniach wykorzystano powszechnie używane materiały stomatologiczne oraz trzy typy lamp polimeryzacyjnych stosowane w gabinetach dentystycznych: halogenową, ksenonową i lampę z diodami półprzewodnikowymi. W celu porównania własności lamp zmierzono ich parametry promienne. Pomiary temperaturowe wykonano w warunkach in vivo oraz in vitro. Stwierdzono istotne różnice, zarówno w wartości jak i w szybkości przyrostu temperatury polimeryzowanych materiałów w zależności od typu lampy i rodzaju użytego materiału. Na podstawie wyników badań można stwierdzić, że niewłaściwe użycie lampy polimeryzacyjnej stwarza możliwość uszkodzenia tkanek zęba.
In the article the test results are presented, which show the dynamics of temperature change during polymerization of restorative dental materials illuminated by different light sources. Most popular dental materials were examined as well as three different lamps: halogen, xenon and LED-based. The parameters of those lamps were measured in order to compare their characteristics. Temperature measurements were conducted in both in vivo and in vitro conditions. Significant differences were observed in magnitude and temperature increase rate depending on the light source and the type of used material. It was proven that improper choice of illuminating lamp may lead to a damage of dental tissue.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 9, 9; 44-47
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie powierzchni obszaru spalonego na podstawie danych z termogramów
Determining a burnt area based on the data from thermograms
Autorzy:
Szajewska, A.
Szajewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/155400.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
external fire
picture analysis
thermography
analiza obrazu
termografia
pożar zewnętrzny
Opis:
W pracy przedstawiono sposób analizy obrazu, umożliwiający obserwacje rozwoju pożaru, oraz obliczanie powierzchni obszaru spalonego. Analiza wykonywana została na podstawie termogramów z umieszczonymi markerami umożliwiającymi określenie orientacji obrazów względem współrzędnych przestrzennych. Przedstawiona metoda umożliwia zbieranie empirycznych danych na temat dynamiki rozwoju pożarów zewnętrznych zwłaszcza do zastosowania w technikach symulacyjnych przy zbieraniu danych empirycznych.
To test the fire development observation method presented in the paper, there was conducted an experiment which allowed gathering the data essential for determining increments of a burnt area. The experiment consisted in recording digital images taken during controlled common reed burning. Images in the visible light and IR were taken in fixed time intervals during the experiment. Digital processing of the images was performed after finishing the burning in order to mark out the areas covered by fire. Marking shifts of the fire front was made by analyzing successive thermograms of the thermal image. Fig. 4 presents the input images in the visible light, in IR and during morphological transformations. Fig. 1 shows the flowchart of the algorithm for determining the burnt area. Segmentation by thresholding, conjuction and logical disjunction on successive matrices of thresholded pictures was performed in order to determine the burnt area in the picture. The burnt area was calculated by summing up all products of partial areas matrices and a binary resulting matrix with identical coordinates (4). The partial areas were determined by orthorectification of projection onto a plane of individual pixels of the thermal camera matrix (Fig. 7). The resulting value of the burnt area was verified and compared with measurements of the area taken after completing the experiment. The difference in the size of the area did not exceed 5%.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 894-896
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sposób wykonania opracowań termograficznych obiektów walcowych i stożkowych
Autorzy:
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/130386.pdf
Data publikacji:
2001
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
obiekt cylindryczny
obiekt stożkowy
termografia
cylindrical object
conical object
thermography
Opis:
Termogramy obiektów walcowych obarczone są zniekształceniami geometrycznymi i radiometrycznymi. Opracowanie termograficzne powinno przedstawiać rozkład temperatury na powierzchni obserwowanego obiektu wolny od błędów systematycznych. Niniejsza praca przedstawia sposób wykonania termogramów i ich późniejsze przetworzenie.
Thermographic images of the cylindrical objects are distorted by the geometrical and radiometrical errors. Distribution of the temperature on the surface of the object should be presented without the systematic errors. The way of the making the thermographic images of the cylindrical objects and their processing is describes in this paper.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2001, 11; 3-41-3-46
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości wykorzystania termografii aktywnej do lokalizacji zbrojenia w elementach żelbetowych
Possibilities of using active ir thermography for localization of steel bars in reinforced concrete
Autorzy:
Noszczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/134750.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
active thermography
non-destructive testing
material inclusions
detection of rebar
Opis:
The paper presents the possibility of using non-destructive testing with active thermography to the location of reinforcement in concrete elements. Four reinforced concrete elements in the form of beams with dimensions of 24 x 24 x 200 cm was researched. The beams had the main reinforcement with diameters sequentially: 12 mm, 16 mm, 20 mm and 25 mm. Stirrups with a diameter of 6 mm were placed every 20 cm. Lagging for the main reinforcement of test surface was 26 mm. Reinforced concrete elements were heated with an infrared lamp and thermal images were recorded periodically at intervals of 1 min. Preliminary studies have shown that detection of reinforcement in concrete elements using active thermography is possible. The rebar was visible on the thermograms from the start of the cool down phase for about 20 min after. The study contains a description of the test stand, and the tests performed. The paper also highlighted the problems encountered on the implementation of research and prospect of development active thermography as a non-destructive testing.
Źródło:
Technical Issues; 2016, 2; 39-44
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Practical assessment of accuracy of thermographic indirect measurements
Autorzy:
Pacholski, K.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114508.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
errors and uncertainty
infra-red (IR) thermography
emissivity metallurgy
slag
Opis:
: In this paper, the basis of error and uncertainty assessment for thermographic measurement of temperature is presented. An engineering simplified analytical approach of determining the coverage coefficient is described for different number of thermal images taken into analysis and different contributions of A and B-type of uncertainties. In the form of an example, the entire procedure of uncertainty assessment was used for emissivity. The exemplary calculus are presented for emissivity in LWIR spectral range.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 278-281
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic eye corners detection and tracking algorithm in sequence of thermal medical images
Autorzy:
Strąkowska, M.
Strąkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/114658.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
eye corners detection
point tracking
IR thermography
thermal image processing
Opis:
The article presents automatic eye corners detection algorithms in thermal images. Its target application is to perform quick and unnoticed measurement of human body temperature. It is proved that the temperature of eyes’ corners is the most reliable and stable temperature considering infrared imaging. That measurements were done manually so far. Our approach is to do this automatically and create complete system for measurement of core human body temperature in crowded places where it is impossible to do this in another way (for example on the airport, railway station). Such system could prevent people for spreading off the epidemic. Two proposed algorithms are presented: first based on morphological operations and geometric features of human face, second based on the cross-correlation and idea of pattern tracking. The selection of appropriate ROI size for reliable temperature extraction was tested according to the distance to person under observation.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 199-202
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Various applications of complex thermal impedance for transient and AC heat transfer analysis
Autorzy:
Więcek, B.
De Mey, G.
Strąkowska, M.
Chatziathanasiou, V.
Gmyrek, Z.
Strzelecki, M.
Chatzipanagiotou, P.
Powiązania:
https://bibliotekanauki.pl/articles/114707.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal impedance
Nyquist plot
Laplace transform
heat transfer
IR thermography
Opis:
This paper presents the concept and three practical examples of using complex thermal impedance for characterisation different thermal objects. The first problem describes estimation time shift between power and temperature in electric distribution systems with non-sinusoidal currents. The second example discussed here, shows the estimation of power losses distribution in the magnetic punched ferromagnetic strips. The third application presents the inverse thermal modelling of 3-layer biomedical objects (tissues) to estimate the thermal parameters. More details of the presented problems are in the appropriate papers of the authors referenced here.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 210-214
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies