Assessment of feasibility the use of infrared techniques in aviation : testing structures and aviation parts
Autorzy:
Sobieszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/243819.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
NDT
composites
sandwich composites
active thermography
passive thermography
Opis:
This paper presents the use of infrared thermography in aviation. Each of the described applications has been proved experimentally and revealed the advantages and disadvantages of the thermography method. Thermography is a discipline of research that allows observation of many phenomena, e.g. simple temperature analysis, defectoscopic tests and actions of aerodynamic. Its use in aviation is multidirectional therefore; thermography is an attractive method for research. Thermal techniques seem simple; however require extensive knowledge of infrared radiation, the areas in which this technique is used, the influence of camera parameters on its capabilities and software knowledge applied depending on the purpose. This paper undertakes the verification of temperature analysis method, which is based on the tests of whole machine assembly and its parts during their operation - widely known as passive thermography. Another raised issue is defectoscopic study which aim is to detect structural defects by non-destructive testing (NDT) - active thermography. Several types of sandwich and composite materials were selected, and on the basis of the test results the limitations and possibilities of thermography in the field of active thermography were concluded. The last application considered in this study is the use of thermography for aerodynamic testing, i.e. verification transition point, laminar to turbulent layer on the aerodynamic profile.
Źródło:
Journal of KONES; 2016, 23, 4; 479-485
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal sequences database of the skin flaps in breast reconstruction and burns
Autorzy:
Moderhak, Mateusz
Kaczmarek, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/114409.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermography
active dynamic thermography
burns
breast reconstruction
image database
Opis:
This paper presents a database of Active Dynamic Thermography (ADT) thermal sequences gathered throughout 6 year study on ADT application in skin flap blood perfusion monitoring and burn wounds diagnosis. For skin flap monitoring the database comprises of data collected during three different breast reconstruction procedures. The patients were monitored pre, intra and post surgically within 90 days period. The sequences were used in skin flap parametric imaging aimed at reducing complications and improving flap perfusion. For burns investigation patients were monitored following an accident, at the 3-rd day and 21 days after.
Źródło:
Measurement Automation Monitoring; 2019, 65, 1; 26-29
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Pulse Thermography (PT) and Step Heating (SH) Thermography in Non-Destructive Testing of Unidirectional GFRP Composites
Autorzy:
Kamińska, Paulina
Ziemkiewicz, Jarosław
Synaszko, Piotr
Dragan, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/97879.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
pulsed thermography
step-heating thermography
composites
NDT
NDE
GFRP
Opis:
This paper presents two techniques of active thermography i.e. the pulsed thermography technique and the step heating technique. The aim of this article is to compare these two techniques and present the possibilities, advantages and limitations of their use in the context of non-destructive testing of composite materials. The experimental section presents the results of tests carried out on samples of the polymer composites reinforced with glass fiber.
Źródło:
Fatigue of Aircraft Structures; 2019, 11; 87-102
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proposition of a method of determining the thermovision measurement extended uncertainty of the surface temperature of an object close to a camera lens
Autorzy:
Dziarski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/114078.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
uncertainty
thermography
metrology
Opis:
In the article the influence of selected factors occurring during thermal measurements on the uncertainty of thermovision temperature measurement is discussed. A situation in which the observed surface was close to the camera lens was measured (distance less than one meter). Based on the type B determination methodology described in the literature on the subject, a method of calculating the measurement extended uncertainty is proposed. A division of factors influencing the thermovision temperature measurement uncertainty into external factors and internal factors is also proposed. Factors associated with the conditions prevailing during the measurement, the geometry of the measurement system and the properties of the observed surface were considered external factors. Factors related to the calibration of the thermal imaging camera, the sensor matrix used and the properties of its measuring path were qualified as internal factors. The method of determining the value of the camera display at the highest and lowest value of a particular factor is discussed. The probability distribution for each of the external factors was determined. The measuring system constructed is presented. It is explained how the uncertainty shares and expanded uncertainty were determined in accordance with the method proposed.
Źródło:
Measurement Automation Monitoring; 2019, 65, 1; 7-10
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of infrared thermography to non-contact testing of varistors
Autorzy:
Galla, S.
Konczakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/220473.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermography
testing
varistors
Opis:
Testing of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors working in electronic devices as protective elements, on the basis of estimating temperature increments on varistor surfaces, registered by an infrared camera during surge resistance tests with standard voltage levels. To determine acceptable temperature increments on a tested varistor, preliminary testing was performed of P22Z1 (Littelfuse) and S07K14 (EPCOS) type varistors, working first at a constant load and presently during surge tests,. The thermographic test results were compared with measured varistor capacity values before and after tests. It was found that recording with thermography temperature increments greater than 6°C for both P22Z1 and S07K14 varistor types detects total or partial loss of varistor protective properties. The test results were confirmed by assessment of protective properties of varistors working in output circuits of low nominal voltage devices.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 677-688
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Observation using thermography of post-operative reaction after fascial manipulation®
Autorzy:
Fidut-Wrońska, J.
Chołuj, K.
Chmiel, J.
Pikto-Pitkiewicz, K.
Majcher, P.
Powiązania:
https://bibliotekanauki.pl/articles/2085037.pdf
Data publikacji:
2019
Wydawca:
Instytut Medycyny Wsi
Tematy:
fascial manipulation
thermography
inflammation
Opis:
Introduction and objective. Fascia Manipulation® is one of the methods focusing on the deep fascia. The assumption is that fascial manipulation is carried out on precisely determined points – coordination centres (cc), and on a limited area so as the friction occurring during manipulation would cause a local rise in temperature due to the inflammatory reaction. Rise in temperature influences modification in consistency of elementary matter in the manipulated area, and by the same token causing a decrease in the negative effects of fascia densification which stems from accumulation of hyaluronic acid. The purpose of the research is to prove the thesis that fascial manipulation causes local rise in temperature due to inflammatory reaction. Materials and method. For the research, 25 individuals with densification in lower limb area were qualified. They were exposed to a single, 3-minute facial manipulation®. By means of a thermal-imaging camera, changes in the temperature of the body in the examined area were evaluated. The body’s temperature evaluation was carried out 8 times: before the treatment, 5 minutes after the treatment, and, next, 6, 12, 18, 24, 36, 48 hours after the treatment. Results. The average surface temperature of the treated area before mobilization was 33.4°C. A statistically relevant increase in temperature was already observed 5 minutes after the treatment (increase of 0.5°C; p<0.001). However, the highest temperature was observed 24 hours after mobilization (increase of 2.4 °C). The difference between the first and 7 other measurements was statistically relevant (p<0.001). Conclusion. The statistically relevant increase in temperature under the influence of fascial manipulation® in the treatment area can confirm the occurrence of inflammatory reaction.
Źródło:
Annals of Agricultural and Environmental Medicine; 2019, 26, 3; 468-471
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stereoskopia w interpretacji termogramów obiektów inżynierskich
Interpretation of thermograms of constructions with use of stereoscopy
Autorzy:
Grońska, J.
Grzesik, I.
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/131304.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
termografia
stereoskopia
thermography
stereoscopy
Opis:
Termogram przedstawia rozkład temperatury na obserwowanej powierzchni, przez co znacznie się różni od obrazu w świetle widzialnym. Inną cechą szczególną termogramu są rozmycia konturów, spowodowane płynnością rozkładu temperatury na powierzchni obiektu. Utrudnia to identyfikację szczegółów na termogramie, a zatem umiejscowienie na powierzchni obiektu (zwłaszcza obiektów wielopowierzchniowych) odczytanej wartości temperatury. Dla ułatwienia interpretacji autorzy próbują zastosować wykonywanie i stereoskopową obserwację stereotermogramów. Analizę jakości modelu stereoskopowego przeprowadzono na termogramach budynków przemysłowych i mieszkalnych. Dokładność pomiaru na stereotermogramach oceniano przez porównanie go z wynikami pomiaru geodezyjnego i fotogrametrycznego. Stwierdzono, że model przestrzenny jest wyraźnie widoczny wtedy, kiedy oglądamy obrazy w małej skali. Powiększanie obrazu powodowało pogorszenie jakości obserwacji, czasami do tego stopnia, że nie można było osadzić znaczka pomiarowego na powierzchni modelu. Dokładność odtworzenia przestrzennego położenia elementów obiektu zarejestrowanego na stereotermogramie nie jest wysoka. Dla uzyskania dokładnych informacji geometrycznych o obiekcie stereotermogramy nie zastąpią steropary zdjęć fotograficznych (nawet tych wykonanych niewysokiej jakości kamerami cyfrowymi), mogą być natomiast bardzo pomocne przy interpretacji rozkładu temperatury.
Authors are proposing use of stereoscopic observation of thermograms in order to simplify their interpretation. Analysis of the quality of the stereoscopic model has been made on the images of industrial and habitable buildings. It has been found that model is clearly visible when it is seen in a low scale. Enlargement of the image resulted in decreasing accuracy of observations. Accuracy of spatial placement of objects' elements recorded on the stereograph. In order to acquire geometri-cally accurate information about the object it is necessary to make a photographical stereopair, but thermographical stereograph is very useful in the interpretation of temperature distribution.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2003, 13b; 371-377
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New opportunities for infrared thermography in medicine
Nowe możliwości zastosowania termografii w medycynie
Autorzy:
Ring, F.
Jung, A.
Żuber, J.
Powiązania:
https://bibliotekanauki.pl/articles/261638.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia
termowizja
thermography
thermovision
Opis:
In the last b50 years, termography imaging has found many applications inj medicine. Nowadays, the adventage of computer technology and image processing enable the development of thermography techniques. In this paper some new developments and historical milestones, are reviewed.
Termografia znajduje wiele zastosowań w medycynie od blisko 50 lat. Dynamiczny rozwój nowoczench technologii komputerowych oraz aparatury termowizyjnej umożliwił dalszy postęp technik termograficznych. W pracy zaprezentowano zarówno nowe, jak i już historyczne osiągnięcia.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 1; 28-30
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active Thermography in Qualitative Evaluation of Protective Materials
Autorzy:
Gralewicz, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/90338.pdf
Data publikacji:
2009
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
protective material
active thermography
defects
Opis:
This is a study of the possibilities of a qualitative evaluation of protective materials with active thermography. It presents a simulation of a periodic excitation of a multilayer composite material. Tests were conducted with lock-in thermography on Kevlar® composite consisting of 16 layers of Kevlar® fabric reinforced with formaldehyde resin with implanted delamination defects. Lock-in thermography is a versatile tool for nondestructive evaluation. It is a fast, remote and nondestructive procedure. Hence, it was used to detect delaminations in the composite structure of materials used in the production of components designed for personal protection. This method directly contributes to an improvement in safety.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2009, 15, 4; 363-371
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active dynamic thermography in mammography
Autorzy:
Kaczmarek, M.
Nowakowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1965793.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska
Tematy:
thermography
breast cancer
mathematical modelling
Opis:
We discuss limitations of the known methods of IR imaging in diagnostics of breast cancer. In conclusion we show that the known methods, based on simple observation of external temperature distribution, are not fully effective. Even advanced pattern recognition could not help in analysis of static images. May active dynamic thermography, known in non-destructive testing of materials, be of any help in breast cancer diagnostics? Analysis of thermal transients forced by external thermal excitation shows, even on simple models, that one may expect a visible improvement in resolution after such excitation. Applied models allow analysis of both static and active thermograms. Basing on the models one may recognise elements of the internal structure of a breast not visible in static pictures. This method, new in clinical practice, seems to be promising, but requires further studies.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2004, 8, 2; 259-267
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remarks on noise removal in infrared images
Autorzy:
Budzan, S.
Wyżgolik, R.
Powiązania:
https://bibliotekanauki.pl/articles/114180.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermography
infrared images
noise removal
Opis:
Noise removal in IR (Infra Red) images is very popular in recent years, however the same approach is utilized as for vision images, with no or minor changes. In this work we wanted to show the results of noise removal for selected filters. We focused on investigation of some filters normally used for image processing and their influence to IR image quality. In IR imaging the choice of filter depends mainly on the purpose of the processing, e.g. detection of small objects in complex images, edge and contour detection or removal of non-uniformity of the detector array. The performance of the selected noise reduction filters was evaluated using PSNR (Peak Signal-to-Noise Ratio) and MAE (Mean Absolute Error) quality measure, greater value of the PSNR and lower value of the MAE indicate better noise reduction. The results are shown only for few images from our database which contain over 2000 of IR images.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 187-190
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of selected thermal properties of components of bonded joint for purposes of active thermography
Autorzy:
Fidali, M.
Kruczek, T.
Kurpiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/114512.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diffusivity
specific heat
active thermography
Opis:
Adhesively bonded joints are widely used in the automotive industry. Different kinds of defects could appear in the bounded joint during its creation. The defects could be detected by use of many destructive and non-destructive methods including active thermography. Application of active thermography requires setting of test parameters. It could be done based on analytical or numerical models which requires material properties of bonded components. In the article presented results of measurements of thermal diffusivity and specific heat of automotive steel and adhesive for purposes of further modelling and estimation of active thermography test parameters.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 102-106
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Heat Transfer in Radiators for LED Light Sources Using Thermography and Numerical Modeling
Autorzy:
Szubel, M.
Basista, G.
Karkoszka, L.
Powiązania:
https://bibliotekanauki.pl/articles/114533.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
LED
radiators
thermography
numerical modelling
Opis:
Light-emitting diodes – LED, appeared on the market in the 60s of the last century, and today it is the fastest developing lighting technology. Due to high heat flux on the small surface of the individual diodes, problems related to the light source cooling become to be one of the basic ones. The paper presents results of the thermographic and numerical analyses of the chosen design of the LED lamp radiator. Experimental and computational data have been compared and discussed.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 257-260
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic monitoring of the power transformers
Autorzy:
Lisowska-Lis, A.
Powiązania:
https://bibliotekanauki.pl/articles/114168.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformer
thermography
diagnostics
monitoring
cooling
Opis:
Results of thermographic monitoring of exemplary power transformers are presented in the paper. Series of thermograms were taken. The areas on the transformer surfaces were analysed for higher temperature in aspects of: the electrical insulation condition of the transformer, the area on the surface, the season of the measurement. The thermograms indicated inefficient cooling for the transformers with deteriorated electrical insulation, especially during the summer season.
Źródło:
Measurement Automation Monitoring; 2017, 63, 4; 154-157
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Foreground extraction in images obtained in active thermography
Autorzy:
Kurpiński, M.
Jamrozik, W.
Powiązania:
https://bibliotekanauki.pl/articles/114529.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
active thermography
image processing
segmentation
Opis:
Detecting defects in adhesively bonded joints, using active thermography methods is very promising NDT testing method. In many cases, tests are made with agreed conditions, where a test object is always in specific place of IR camera view. Although, for needs of industry, system should be able to adjust Region of Interest in order to prevailing conditions. Therefore, it is necessary to develop appropriate method for this task. The paper describe one of the easiest attempt to separate foreground of an IR image sequence acquired by Lock-In Thermography (LT) and Pulse Thermography (PT). Proposed approach is based on segmentation and morphological operations. The IR image sequences of 11 various samples were used for this task. Obtained results show that elaborated technique of foreground object extraction is possible.
Źródło:
Measurement Automation Monitoring; 2017, 63, 4; 150-153
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-destructive evaluation of rescue and patrol unmanned aerial vehicle
Autorzy:
Pawluczy-Majka, J.
Powiązania:
https://bibliotekanauki.pl/articles/243854.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
UAV
NDT diagnostics
active thermography
Opis:
With the growing intensity of civil usage of the UAV, one of the most important problems is safety. It consists of operational safe use of the UAV in the common air area and reliability of the aerial vehicle construction. Each flying object is subjected to external loads, which influence on it in flight and on the ground. The external loads are mainly caused by aerodynamic, weight and inertia influence, ground reaction force and the power unit [1]. That is why during service, UAV structures are prone to many mechanical and environmental conditions that can damage to composite structures in the form of delamination, fiber breakage, and matrix cracking. Monitoring the level and type of damage to a composite structure is vital to determining the component’s structural integrity and preventing the failure of the structure during flight [2]. Non-destructive testing which has been used so far to identify defects in the aircraft structure made from metallic materials has a quite limited application in the case of composite structures. With the growing use of composites in the aviation industry, a necessity appears to work out a method allowing identification of technological defects and damages appeared in the process of the UAV’s operation. The answer to the appearing demand could be, for instance, the active thermography technique used for the thin wall test of the skin elements of the UAV. The obtained research results bring closer the problem of selection of the quick, well-fitted non-destructive testing method depending on the kind of the diagnosed construction.
Źródło:
Journal of KONES; 2014, 21, 4; 411-416
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of flow boiling heat transfer in a rectangular minichannel using liquid crystal and infrared thermography
Autorzy:
Strąk, K.
Piasecka, M.
Powiązania:
https://bibliotekanauki.pl/articles/175560.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flow boiling heat transfer
rectangular minichannel
enhanced foil surface
liquid crystal thermography
infrared thermography
Opis:
This paper presents results of flow boiling heat transfer in two parallel asymmetrically heated vertical minichannels. The heating element for Fluorinert FC-72 flowing in the minichannels was a thin foil with an enhanced surface on the side in contact with the fluid. The channels were observed from both sides through glass panes. Two of the panes allowed us to observe the two phase flow patterns on the enhanced surface of the foil, while the other two panes were used for simultaneous measurement of temperature on the smooth side of the foil. The temperature was measured by applying two contactless methods. One was liquid crystal thermography (LCT), which required treating the foil surface with thermochromic liquid crystals (TLCs), and the other was infrared thermography (IRT), which required coating the foil surface with black paint. Calculations were performed on the basis ofa one-dimensional model to determine the heat transfer coefficient at the foil-fluid interface from the Robin boundary condition. The experimental results were graphically represented as the foil temperature and the heat transfer coefficient against the distance from the minichannel inlet and as LCT and IRT images obtained for saturated boiling.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 128; 97-118
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of Bonded Joint Defects by use of Lock-in Thermography
Autorzy:
Kurpiński, M.
Fidali, M.
Powiązania:
https://bibliotekanauki.pl/articles/114547.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
lock-in thermography
NDT
bonded joints
Opis:
Joining of two or more materials using adhesives is one of the most widely used way to connect and/or seal steel panels used in the automotive industry. Due to instabilities of the technological process a different kind of defects could appear in the adhesively bonded joints. There are many destructive and non-destructive methods allowing investigation of defects of bonded joints. In this article lock-in thermography (LT) technique was used to detect of discontinuities in sealing joints between two steel plates. Results of the research shown the defect of bonded joints could be recognised effectively however it is necessary to ensure proper test conditions.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 333-336
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena aktywności wybranej grupy mięśni na podstawie pomiaru zmian temperatury powierzchni ciała
Evaluation of activity of a chosen group of muscles on the basis of temperature changes on the skins surface
Autorzy:
Anwajler, J.
Dudek, K.
Powiązania:
https://bibliotekanauki.pl/articles/261644.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia
aktywność mięśni
thermography
muscular activity
Opis:
W pracy analizowano możliwość oceny aktywności mięśni na podstawie pomiaru zmian temperatury bezpośrednio nad powierzchnią pracujących mięśni. Przedstawiono wyniki pomiaru zmian temperatury na powierzchni skóry nad grupą mięśni zginających przedramię po ćwiczeniach czynnych z oporem, wykonywanych asymetrycznie. Określono optymalne warunki rejestracji termograficznej zmian temperatury skóry nad mięśniem dwugłowym ramienia oraz zależność tych zmian od intensywności ćwiczeń.
The aim of this work was to analyse the possibility of evaluating muscular activity on the basis of temperature changes measured directly over the surface of working muscles. Temperature changes on the skin surface over the group of muscles responsible for flexing the forearm after active exercises with resistance carried out asymmetrically, were measured. The following parameters were determined: optimal conditions for thermal recording of the temperature changes of the skin's surface over the biceps muscle of forearm and the influence of the exercises intensity on temperature distribution.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 1; 20-22
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Image processing techniques for roi identification in rheumatoid arthritis patients from thermal images
Autorzy:
Wasilewska, A.
Pauk, J.
Ihnatouski, M.
Powiązania:
https://bibliotekanauki.pl/articles/386454.pdf
Data publikacji:
2018
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
dynamic thermography
image processing
segmentation
inflammation
Opis:
Rheumatoid arthritis (RA) is a systemic autoimmune disease that manifests itself by joint inflammation, swelling, pain, tenderness and may involve extra-articular organs in severe cases. Joint inflammatory lesions are associated with higher temperature due to increased vascularity in the area of inflamed tissues. This papers aimed to identify heat patterns from ROIs to interpret the presence of inflammation in rheumatoid arthritis patients. The thermovisual image sequences were collected from 65 patients with Rheumatoid Arthritis (RA). Infrared images were generated by a thermal scanning camera (FLIR E60bx Systems Inc., USA). Separate recordings of left and right foot temperature changes were performed for 3 minute periods. The temperature measurement was performed at the moment right after cold water immersion (post-cooling temperature) and at the moment after thermal recovery (post-recovery temperature). The recording of 3-minute foot thermal recovery was used for analysis. Automatically identified ROI corresponds to the area of the soft tissues covering cuboid and navicular bone.
Źródło:
Acta Mechanica et Automatica; 2018, 12, 1; 49-53
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczne zastosowanie badań termowizyjnych przez energetykę zawodową
Practical application research infrared by power industry
Autorzy:
Kowalczyk, R.
Pacholski, K.
Walczak, J.
Olbrycht, R.
Powiązania:
https://bibliotekanauki.pl/articles/267564.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
termowizja
energetyka zawodowa
thermography
power industry
Opis:
Wykorzystanie kamery termowizyjnej do oceny stanu technicznego aparatury rozdzielczej i dystrybucyjnej systemu energetycznego ma bezpośredni wpływ na zachowanie ciągłości dostaw energii elektrycznej. Szczególne warunki środowiskowe, odnoszą się bezpośrednio do sposobu interpretacji wyników pomiarów. Zaprezentowane przykłady badań termowizyjnych, obrazują mechanizmy działań stosowane w praktyce zawodowej. Uzmysławiają, że zignorowanie nawet najmniejszych nieprawidłowości może skutkować rozległą awarią systemu energetycznego. Natomiast prawidłowa weryfikacja termogramów umożliwia diagnostykę sytemu bez konieczności pozbawiania dopływu energii elektrycznej do odbiorców przemysłowych i indywidualnych.
The use of a thermal imaging cameras to analyze the technical condition of the switchgear and distribution of the energy system has a direct impact on the continuity of electricity supply. Specific environmental conditions relate directly to how to interpret the results. The presented examples of research of the thermal imaging, illustrate the mechanisms of action used in professional practice. They make clear that ignoring even the smallest irregularities may result in the failure of an extensive energy systems. Whereas the correct verification of the thermal image allows diagnostics of the system without depriving voltage transmission facilities and thus without disconnecting customers.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 55; 25-28
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrochemical capacitor temperature fluctuations during charging/discharging processes
Autorzy:
Galla, Stanisław
Szewczyk, Arkadiusz
Lentka, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/220829.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrochemical capacitor
statistical parameters
quality
thermography
Opis:
The paper presents a proposal of using additional statistical parameters such as: standard deviation, variance, maximum and minimum increases of the observed value that were determined during measurements of temperature fields created on the surface of the tested electrochemical capacitor. The measurements were carried out using thermographic methods in order to support assessment of the condition of electrochemical capacitor under classic durability tests based on methods of determination of capacity and equivalent series resistance. The possibility of using some statistical parameters in assessment of the electrochemical capacitor quality was illustrated. The applied measurement methodology and the results of research associated with the classic methods of supercapacitors’ assessment are presented. The obtained results indicate that the variability of some statistical parameters of temperature fields can be directly related to changing the values of standard parameters describing electrochemical capacitor, which are capacitance and equivalent series resistance.
Źródło:
Metrology and Measurement Systems; 2019, 26, 1; 23-35
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic evaluation of CaO additive on the process of waste hygienization
Autorzy:
Famielec, S.
Gliniak, M.
Kapjor, A.
Łukasiewicz, M.
Malinowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/101498.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
CaO
Municipal Solid Waste
hygienization
thermography
Opis:
Municipal Solid Waste (MSW) is the mixture of many waste types, including organic waste (garden and park waste, food and kitchen waste, paper and cardboard etc.). Such waste creates a living environment for various microorganism species, many of which are known as pathogenic. The presence of microorganisms in favorable conditions (pH, organic matter content, carbon content, moisture, appropriate granulation) leads to decomposing of organic matter, which is accompanied by an increase in temperature. Microorganisms in waste pose a serious risk for staff operating at waste treatment plants. Moreover, heat released by their activity may cause a fire in waste storage facilities. Therefore, it is necessary to search for methods of waste stabilization and hygienization. The most commonly applied technology for waste stabilization is its processing in Mechanical Biological Treatment (MBT) plants. Such treatment is capital – and timeconsuming, however. Waste liming can become an alternative method for stabilization and hygienization of waste. Lime addition is one of the oldest method known by humans for hygienization of certain waste materials, such as animal waste. Currently, liming is applied in sewage sludge treatment as one of the initial operations and is necessary for further sludge management processes. The aim of the research was to valuate temperature changes during mixed MSW hygienization process with CaO addition in the amount of several percent by using a thermographic camera. The reaction of CaO with waste is short and lasts no longer than 20 minutes. The maximal temperatures were reached after 65-124 seconds from the time of CaO addition. The most dynamic increase in temperature were observed up to approx. 120th second of the process, with the rate dependent on the initial moisture of the material. The observed pH values indicate that the maximal dose of CaO additive should not exceed 3%. Such a dose is sufficient for waste to reach pH 12, which, according to literature, guarantees the deactivation of microorganisms.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/4; 1857-1865
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infrared thermography as a rapid and non-invasive diagnostic tool to detect inflammatory foot diseases in dairy cows
Autorzy:
Gianesella, M.
Arfuso, F.
Fiore, E.
Giambelluca, S.
Giudice, E.
Armato, L.
Piccione, G.
Powiązania:
https://bibliotekanauki.pl/articles/2087735.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dairy cows
foot lesion
infrared thermography
Źródło:
Polish Journal of Veterinary Sciences; 2018, 21, 2; 298-305
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of training on infrared thermographic images of the forelimb and hindlimb joints of healthy racehorses
Autorzy:
Soroko, M.
Górniak, W.
Godlewska, M.
Howell, K.
Powiązania:
https://bibliotekanauki.pl/articles/16539089.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
thermography
horses
surface temperature
exercises
limbs
Opis:
The aim of this study was to evaluate the influence of training on body surface temperature over the joints in racehorses, measured by infrared thermography. The study involved monitoring of 14 Thoroughbred racehorses in 6 imaging sessions over a period of 3 months. Temperature measurements of the forelimb and hindlimb joints were made before and just after training. Joint temperature of limbs increased significantly after training. Environmental temperature had a statistically significant influence on surface temperature over the joints. The lowest surface temperatures were recorded over the metacarpophalangeal and metatarsophalangeal joint and the highest temperatures in the shoulder, elbow, hip and stifle joint. The metacarpophalangeal and metatarsophalangeal joints warmed the least during training, but were influenced the most by differences in environmental temperature. The surface temperature difference before and after training is an important indicator of the thermoregulatory response to exercise in racing horses. Understanding surface temperature changes in response to regular training is necessary for future studies on diagnosing injuries of joints.
Źródło:
Polish Journal of Veterinary Sciences; 2022, 25, 1; 83-92
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies