Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Frequency Response Analysis" wg kryterium: Wszystkie pola


Tytuł:
Frequency response analysis of microcontroller-based discrete-time lead-lag compensators
Autorzy:
Dewantoro, Gunawan
Rizky, Irwin Shauma
Murtianta, Budihardja
Powiązania:
https://bibliotekanauki.pl/articles/949895.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arduino Uno
discretization
frequency response
lag compensator
lead compensator
Opis:
With the rapid advancement of digital processors, filters have been commonly implemented using microcomputers. In this study, a low-cost and compact Arduino Uno development board was used to realize digital lead and lag compensators. Arduino boards are very affordable. Consequently, they were investigated to see if they were capable of preserving the frequency response of continuous-time compensators. The experiments required a set of equipment including a function generator, an Arduino Uno development board, a PC-based oscilloscope, and a laptop. The signal frequency was varied from 0 to 500 Hz. Two discretization methods were employed, namely bilinear transformation and matched pole-zero mapping. The results showed that an Arduino Uno board can be utilized to implement lead and lag compensators to some extent. The discrete-time compensator preserved the capability of filtering out certain frequencies. The change in DC gain was negligible, however, there was a significant difference in the cut-off frequency and transient slope. For both discretization methods, the frequency responses at high frequency experienced a rippling profile.
Źródło:
Archives of Electrical Engineering; 2020, 69, 4; 937-950
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology for the Composite Tire Numerical Simulation Based on the Frequency Response Analysis
Autorzy:
Karpenko, Mykola
Skačkauskas, Paulius
Prentkovskis, Olegas
Powiązania:
https://bibliotekanauki.pl/articles/24200834.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
tire
composite
finite elements metod
frequency analysis
numerical simulation
optimization
Opis:
Reliability and maintenance analysis in transport focus on the main objective of accident and incident investigations that benefit to better understanding of the causes of accidents and prevention of them in the future. The conducted research presents theoretical and experimental research on composite pneumatic tire used in transport engineering. The approach of the numerical simulation sequence which is offered in this research facilitates engineers in efficient determination of the dynamic properties and behaviour of vehicle tire at design stage. The tire materials have been tested by employing piezoelectric micro-vibration tests and frequency analyses. The Finite Element Method used for numerical simulation in combination with experimental measurements based on optimization by material frequency response, was applied in modelling tire material behaviour avoiding problems of composite structure modelling. The obtained results indicate that the offered methodology can be used in numerical simulation of composite tire investigation and considering material viscos-elastic properties.
Źródło:
Eksploatacja i Niezawodność; 2023, 25, 2; art. no. 163289
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Condition assessment of transformer insulation using dielectric frequency response analysis by artificial bee colony algorithm
Autorzy:
Bigdeli, M.
Aghajanloo, J.
Powiązania:
https://bibliotekanauki.pl/articles/140546.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
artificial bee colony (ABC) algorithm
condition assessment
dielectric frequency
response (DFR)
transformer insulation
Opis:
Transformers are one of the most important components of the power system. It is important to maintain and assess the condition. Transformer lifetime depends on the life of its insulation and insulation life is also strongly influenced by moisture in the insulation. Due to importance of this issue, in this paper a new method is introduced for determining the moisture content of the transformer insulation system using dielectric response analysis in the frequency domain based on artificial bee colony algorithm. First, the master curve of dielectric response is modeled. Then, using proposed method the master curve and the measured dielectric response curves are compared. By analyzing the results of the comparison, the moisture content of paper insulation, electrical conductivity of the insulating oil and dielectric model dimensions are determined. Finally, the proposed method is applied to several practical samples to demonstrate its capabilities compared with the well-known conventional method.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 45-57
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of other windings on frequency response of power transformers
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/378065.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformer
frequency response analysis (FRA)
modelling of windings
Opis:
The diagnostics of power transformers is a very fast developing branch. Due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. In the FRA measurements of many power transformers there can be observed a first resonance, which position on frequency axis and damping factor seems to be similar for primary and secondary windings. The authors are going to explain this strange phenomenon, not depending on inductance of the winding being measured.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 81; 31-38
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Frequency Response measurement results with end-to-end/interwinding test setup correlation
Autorzy:
Banaszak, S.
Szoka, W.
Powiązania:
https://bibliotekanauki.pl/articles/141647.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Frequency Response Analysis
transformer
winding
deformation
test setup
Opis:
The paper presents the idea of a Cross Test Comparison (CTC) method for the analysis of Frequency Response measurement results. FRA is used to detect deformations or electric faults in transformer windings. At the current stage of FRA method development, it is possible to perform repetitive measurements, however there are still problems with interpretation of test results. Authors of this paper found that analysis of results coming from two test setups (end-to-end and interwinding capacitive), which is done simultaneously is a more sensitive tool to detect some faults, and in addition it binds the influence of both voltage sides of a transformer in a single test result. The paper contains results obtained from laboratory tests, where controlled deformations were introduced into windings and also measurements from industry. The CTC method combines both the end-to-end and capacitive interwinding measurements into a single dataset, by subtracting the amplitudes at the corresponding frequencies. The resulting combined dataset is more sensitive in identifying deviations from baseline measurements.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 51-64
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TLM-method for Computer Modeling of Transformers’ Windings Frequency Response
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/97469.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
TLM
frequency response analysis (FRA)
FRA
transformer windings
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the transmission-line models are applied. The idea of TLM was presented in [1]. While the length of transformer wires is comparable to wave length at high frequency, such approach is reasonable. The paper presents examples of models created for simple windings.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 137-145
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TLM-method for computer modeling of transformers’ windings frequency response
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/376947.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power transformers
FRA
TLM
frequency response analysis (FRA)
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the transmission-line models are applied. The idea of TLM was presented in [1], While the length of transformer wires is comparable to wave length at high frequency, such approach is reasonable. The paper presents examples of models created for simple windings.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 41-47
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
RLC-models for computer modeling of transformers’ windings frequency response
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/376937.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power transformers
FRA
frequency response analysis (FRA)
RLC models
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the RLC models are applied. The idea of lumped parameters models was presented in [6]. The new universal model basing on circuit solution is developed in this paper. Lumped parameters used are calculated with finite element method and Maxwell package. The examples of models created for simple windings were compared to real measurements.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 73; 107-113
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Practical use of RLC-models of transformers’ windings for determination of local displacements
Autorzy:
Banaszak, S.
Gawrylczyk, K. M.
Powiązania:
https://bibliotekanauki.pl/articles/97720.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformer’s diagnostic
frequency response analysis (FRA)
lumped parameter models
Opis:
The diagnostics of power transformers is a very fast developing branch, due to increasing average age of assets and changes in asset management strategies, nowadays companies introduce asset management based on a real technical condition. One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows determination of mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. For the aim of windings impedance modeling the RLC models are applied. The idea of lumped parameters models was presented in [6]. The new universal model basing on circuit solution is developed in this paper. Lumped parameters used in calculations are obtained with finite element method and Maxwell package. The examples of models created for simple windings were compared to real measurements.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 100-109
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza odpowiedzi częstotliwościowej uzwojeń transformatorów w świetle zaleceń projektu normy IEC 60076-18
Frequency Response Analysis in the Scope of Standard Regulations
Autorzy:
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/153925.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza odpowiedzi częstotliwościowej
transformator
diagnostyka
norma
frequency response analysis (FRA)
transformer
diagnostics
standard
Opis:
Analiza odpowiedzi częstotliwościowej (FRA - Frequency Response Analysis) jest jedną z metod diagnostycznych transformatorów energetycznych. Obecnie pomiary wykonywane są w oparciu o doświadczenie diagnosty i instrukcje przyrządów pomiarowych. W ciągu kilkunastu miesięcy opracowana zostanie norma IEC 60076-18, która usystematyzuje technikę wykonywania pomiarów i właściwości przyrządów pomiarowych. Autor, biorąc udział w pracach grupy przygotowującej tę normę, omawia w artykule podstawowe wytyczne do wykonywania takich pomiarów, ze szczególnym uwzględnieniem czynników zależnych od przyzwyczajeń diagnostów, które łatwo można dostosować do znormalizowanych zasad.
Frequency Response Analysis (FRA) is one of diagnostic methods for power transformer state. At present measurements are taken on the base of diagnostic personnel experience and manuals of commercial devices. There are some important measuring issues, given in the paper, which are interpreted in different ways by various diagnostic companies. This leads to difficult or even impossible analysis of measured data, as the FRA method is based on com-parison, very often visual, of recorded curves. In over one year there will be published IEC 60076-18 standard, which describes techniques of taking the measurements and properties of measuring devices. The author is a member of working group preparing this standard. This paper describes basic principles of FRA mea-surements, with focus on issues which have significant impact on measurements, but often depend on personnel habits and can be easily adopted to IEC standard.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 413-416
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja uszkodzeń uzwojeń maszyn elektrycznych na podstawie analizy odpowiedzi częstotliwościowej
Identification of electric machine winding failures on basis of frequency response analysis
Autorzy:
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/156573.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
maszyny elektryczne
analiza odpowiedzi częstotliwościowej
diagnostyka
electric machines
frequency response analysis (FRA)
diagnostics
Opis:
Metoda analizy odpowiedzi częstotliwościowej znajduje coraz szersze zastosowanie w badaniach diagnostycznych urządzeń elektrycznych. Artykuł przedstawia możliwości zastosowania tej metody do wykrywania uszkodzeń uzwojeń maszyn elektrycznych. Badano wpływ zwarć między sąsiednimi zwojami uzwojeń maszyn elektrycznych o zróżnicowanych konstrukcjach i parametrach na kształt zależności częstotliwościowej admitancji.
The frequency response analysis method is more and more frequently used as a diagnostic tool for investigation of electrical device windings. This paper presents a novel application regarding possibilities of this method to detection of faults in electrical machine windings. The influence of turn-to-turn faults between adjacent winding wires in electrical machines of different constructions and parameters on the admittance waveform was investigated.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 11, 11; 767-769
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of frequency response of transformer winding with axial deformations
Autorzy:
Gawrylczyk, K. M.
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/140733.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
transformer
winding
frequency response analysis (FRA)
lumped parameters method
transmission line method
Opis:
One of important methods used for diagnostics of a transformer’s active part is Frequency Response Analysis (FRA). It allows to determine the mechanical condition of windings, their displacements, deformations and electric faults, as well as some problems with internal leads and connections, core and bushings. Still pending problem is interpretation of measurements results. One of approaches is application of computer modeling to simulate various failure modes and connected with them changes in FRA response. The paper presents two types of models, one based on lumped parameters with RLC elements, and one based on distributed parameters with TLM method. Both methods give similar results, comparable to real measurements of simulated coil.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 5-17
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitivity of transformer frequency response measurements to connection configuration
Czułość pomiarów odpowiedzi częstotliwościowej uzwojeń transformatorów w zależności od układu pomiarowego
Autorzy:
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/158396.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
frequency response analysis (FRA)
transformer
winding
deformation
analiza odpowiedzi częstotliwościowej (FRA)
transformator
uzwojenie
deformacja
Opis:
The paper presents results of deformational tests conducted on the real transformer. The aim of the research was to compare the influence of various winding deformations on the frequency response measured in standard end-to-end connection setup as well as in interwinding setup. The results showed that for all kinds of simulated deformations interwinding measurements show changes in wide frequency range. In many cases these changes are easier to be detected than for end-to-end measurements. It is recommended to perform interwinding measurements for transformers having changes in frequency response after standard end-to-end tests.
W artykule przedstawiono wyniki badań mających na celu określenie wpływu lokalizacji i skali deformacji w uzwojeniu transformatora na jego odpowiedź częstotliwościową, której pomiar realizowany był w kilku różnych układach pomiarowych. Standardowym układem pomiarowym, zalecanym również przez wprowadzaną właśnie normę IEC 60076-18, jest pomiar pomiędzy końcami uzwojenia danej fazy. Przedstawione w artykule wyniki pomiarów przy różnych deformacjach, wskazują że większą czułość wykazuje układ międzyuzwojeniowy. Jest on realizowany przy podłączeniu aparatury pomiarowej na wejścia uzwojeń strony niskiej oraz wysokiej danej fazy, przy przeciwnych końcach otwartych (dla tzw. pomiaru pojemnościowego) lub uziemionych (dla tzw. pomiaru indukcyjnego). Dlatego zaleca się wykonywanie takich pomiarów w przypadkach, gdy podstawowy pomiar pomiędzy końcami uzwojenia (tzw. end-to-end) wskaże na różnice pomiędzy przebiegami referencyjnym oraz aktualnym dla danej fazy. W przypadkach braku różnic dla standardowego układu wykonywanie pomiarów międzyuzwojeniowych nie jest konieczne.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 164-167
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigations of interturn faults in winding transformer using frequency response analysis
Badania eksperymentalne zwarć zwojowych w uzwojeniu transformatora z wykorzystaniem metody analizy odpowiedzi w dziedzinie częstotliwości
Autorzy:
Wilk, A.
Powiązania:
https://bibliotekanauki.pl/articles/267613.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
transformator trakcyjny
zwarcie zwojowe
analiza odpowiedzi w dziedzinie częstotliwość
traction transformer
interturn fault
frequency response analysis (FRA)
Opis:
This paper presents sensitivity of Frequency Response Analysis method applied to detection of interturn faults. Frequency response has been carried out on a special Reduced Scale Traction Transformer (RSTT). The RSTT has the wound iron core and eight coils arranged in the “core” type of construction. Many papers have been published on FRA techniques for detection of shorted turns but still there are some issues that need to be addressed. The simulated faults presented in the paper include different values of shorting resistance and different localization of short-circuited turns. From the measurements performed on the transformer without faults, it can be concluded that handmade coils with the same type of construction differ significantly in frequency response. It is also concluded that FRA magnitude spectrum is sensitive to short-circuit, but for some ranges of shorting resistance only. FRA magnitude spectrum also changes with respect to localization of short-circuited turns. The frequency response showed shift in waveforms? in case of some resonant frequencies.
W referacie przedstawiono wyniki badań eksperymentalnych specjalnego Transformatora Trakcyjnego o Zredukowanej Skali (TTZS) z wykorzystaniem metody analizy odpowiedzi w dziedzinie częstotliwości. Pokazano wybrane wyniki analizy FRA nieuszkodzonych symetrycznych uzwojeń strony wtórnej. Zmierzono widmo amplitudowe w przypadku zwarć zwojowych pojedynczych zwojów niektórych cewek. Wykazano, że miejsce wystąpienia zwarcia zwojowego ma wpływ na zmianę widma amplitudowego. Dodatkowo przeanalizowano wrażliwość metody FRA w zależności od wartości rezystancji zwierającej zwój cewki i podano, w jakim zakresie tej wartości możliwa jest detekcja zwarcia zwoju.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 139-142
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane czynniki wpływające na odpowiedź częstotliwościową autotransformatora energetycznego
Factors influencing the frequency response of power autotransformer
Autorzy:
Banaszak, S.
Powiązania:
https://bibliotekanauki.pl/articles/153885.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza odpowiedzi częstotliwościowej
FRA
autotransformator
diagnostyka
odkształcenie uzwojeń
frequency response analysis (FRA)
autotransformer
diagnostics
windings deformation
Opis:
Artykuł omawia wyniki badań deformacyjnych przeprowadzonych na autotransformatorze RTdxP 160 MVA. Badania polegały na kontrolowanym wprowadzaniu zmian w strukturę transformatora i rejestrowanie ich wpływu na pomiary odpowiedzi częstotliwościowej (FRA). Zbadano w ten sposób wpływ rodzaju medium izolacyjnego oraz deformacje w uzwojeniach regulacyjnym i wysokiego napięcia (szeregowym). Uzyskane wyniki umożliwiły wyciągnięcie wniosków dotyczących poprawnej interpretacji i analizy krzywych FRA.
Results of deformational tests performed on RTdxP 160 MVA autotransformer are described in the paper. It was based on the infliction of controlled changes in transformer's structure, and changes in measurements of FRA curves (Frequency Response Analysis) were detected. The first issue analyzed in the experiment was change of insulating liquid. It gave clear results - a shift of transformer response along frequency, resulting from permittivity changes of insulating medium. Following tests showed influence of rough deformations of regulation windings, as well as, influence of small deformations in series winding (HV). Part of the HV winding was deformed axially and radially. Also some short-circuits between windings were simulated. On the base of obtained results it was possible to draw conclusions concerning correct interpretation and analysis of FRA results. One of important conclusions is that small changes in winding geometry or local short-circuits can be difficult to detect in case of geometrically large transformers.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 364-367
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies