Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transients" wg kryterium: Temat


Wyświetlanie 1-39 z 39
Tytuł:
Effect of Hydraulic Characteristics on Fluid Transients Analysis under Different Types of Control Valves
Autorzy:
Al-Zaidi, Basim M.
Ismaeel, Abaas J.
Powiązania:
https://bibliotekanauki.pl/articles/2202314.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hydraulic characteristics
fluid transients
valve
Opis:
In this study, several types of valves were used to study the impact of the valves types and closure characteristics on fluid transients. The valve closure curves, which are the variation of the effective valve opening as a function of percentage opening area, were derived for different selected valves. Six different types of valves were selected to study the effect of the valves types on fluid transient conditions. For simplification, a very simple pipeline system was assumed and presented in this study. The system is about two pipes connected in a series junction and they take the water from a constant-level reservoir at upstream and a valve at downstream. The duration of valve closure was taken as six seconds which plays an important role in the pressure development in the system. A method of characteristics is applied to compute the transient conditions under gradual closure of the valves. Valve data of various forms were compiled and reported as discharge and headloss coefficients as a function of valve opening. The effect of valve geometry and operation on the relative valve opening were compared. Discharge and headloss coefficients were also compared between valve types. The study concluded that transient conditions depend on the valve type. The comparison between the results of all valve types indicated that the changes in pressure and discharges depend on valve type where there is a difference in effective valve opening. It can be concluded that the valve with the highest value of valve effective opening has less effect on transient conditions, i.e., the faster changes of effective valve opening the larger the effect on transient conditions (discharge and the greater the magnitude of the pressure wave). This study would help to select the property valve in pipeline design.
Źródło:
Journal of Ecological Engineering; 2022, 23, 12; 111--123
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The modeling of centrifugal pump transients
Autorzy:
Szymczyk, J.
Karaśkiewicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/175255.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
rotodynamic pumps
complete pump characteristics
transients
Opis:
Centrifugal pumps are part of larger hydraulic systems. These hydraulic machines can work not only in the pumping mode but in a number of other modes whose job description is possible using complete characteristics. Some of these modes, such as the turbine mode and the reversed turbine mode, may have practical significance. Knowledge of the transition from one steady state to another state allows to estimate instantaneous values such as, e.g., flow current and torque, which may be even a few times higher than nominal. The principal issues in these transients are amplitudes of parameters of these pumps and the time constants associated with the characteristics of the system.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 130; 83-92
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Output characteristics of step-down (Buck) power converter
Autorzy:
Janke, W.
Bączek, M.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/201669.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DC-DC converters
output characteristics
load transients
Opis:
The output characteristics of switched-mode dc-dc buck power converter are discussed. The shape of output characteristics is especially important for converters used for supplying modern processors. An output impedance is usually used for description of output characteristics. Many efforts are described in the literature to obtain the satisfastory features of closed-loop output impedance. Another approach, presented in the paper, is based on the concept of the output voltage response corresponding to the load conductance change, and is expressed by hr transmittance. Simulations of output characteristics of the buck converter in frequency and in time-domain have been performed for the ideal case as well as for a more realistic situation, with the parasitic resistances of converter elements included. The measurement results differ substantially from characteristics calculated for an ideal converter and are in good consistency with simulations including parasitics.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 4; 751-755
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of transformer modeling on riser pole arresters behavior during switching transients
Autorzy:
Abbaszadeh, A.
Abedi, M.
Doustmohammadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/140474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arresters
ATP software
ferroresonance
transformer
power system transients
Opis:
Arresters are widely used in power systems to protect other equipment against overvoltages. However, in some conditions, they can’t operate successfully. One of the disturbances leading to the failure of the riser pole arresters is the ferroresonance overvoltages. In this paper, at first the influence of different transformer simulation models of ATP software on the occurrence of ferroresonance is studied and then the effect of ferroresonance on the riser pole arrester has been scrutinized through the thermal and electrical performance of the arrester in an underground distribution system. The results show that the arrester temperature rises due to energy dissipation in a ferroresonance circumstance, which indeed may result into the explosion of the arrester. Also, applying different models of the transformer in the ATP software and comparing the results, it is shown that the available models do not show the same effect on the arrester.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 717-730
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved method for simulating transients of turbulent pipe flow
Autorzy:
Zarzycki, Z.
Kudźma, S.
Urbanowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/280935.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
unsteady pipe flow
transients
waterhammer
efficient numerical simulation
Opis:
The paper presents the problem of modelling and simulation of transients during turbulent fluid flow in hydraulic pipes. The instantaneous wall shear stress on a pipe wall is presented in the form of integral convolution of a weighting function and local acceleration of the liquid. This weighting function depends on the dimensionless time and Reynolds number. Its original, very complicated mathematical structure is approximated to a simpler form which is useful for practical engineering calculations. The paper presents an efficient way to solve the integral convolution based on the method given by Trikha (1975) for laminar flow. An application of an improved method with the use of the Method of Characteristic for the case of unsteady flow (water hammer) is presented. This method is characterised by high efficiency compared to traditional numerical schemes.
Artykuł przedstawia zagadnienie modelowania i symulacji przebiegów przejściowych podczas turbulentnego przepływu cieczy w przewodach ciśnieniowych. Chwilowe naprężenie styczne na ściance przewodu przedstawiono w postaci całki splotowej z funkcji wagi i przyspieszenia cieczy. Funkcja wagi dla naprężenia stycznego na ściance przewodu zależy od czasu bezwymiarowego i liczby Reynoldsa. Ma ona zawiłą postać matematyczną, dlatego aproksymowano ją do prostszej postaci, przydatnej do praktycznych obliczeń inżynierskich. Przedstawiono efektywny sposób rozwiązania całki splotowej, opierając się na metodzie podanej przez Trikha (1975) dla przepływu laminarnego. Podano zastosowanie ulepszonej metody symulacji naprężenia stycznego do metody charakterystyk podczas uderzenia hydraulicznego. Charakteryzuje się ona dużą efektywnością w stosunku do metody tradycyjnej.
Źródło:
Journal of Theoretical and Applied Mechanics; 2011, 49, 1; 135-158
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical solutions for the control and command system of a Plasma Focus device
Autorzy:
Martin, D. I.
Zoita, V. I.
Cotruta, D. A.
Jianu, A. V.
Ighigeanu, D. I.
Bestea, V. I.
Powiązania:
https://bibliotekanauki.pl/articles/147621.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
control system
electromagnetic transients
galvanic separation
plasma focus
Opis:
The paper presents the technical problems related to the electrical control and command system (ECC system) for the plasma focus installation IPF-4/5A having the following main parameters: 1 MA plasma current and 40 kJ energy stored at 20 kV charging voltage. The ECC system applies 23 interlocked logical commands, acquires and processes 28 logical states, acquires, processes and displays continuously the main slow-varying signals coming from IPF-4/5A subassemblies. All the plasma focus installation operational sequences are governed by strict hard and soft interlocking using in parallel two control and command systems: one based on PC-control methods and another based on classical control techniques.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 89-91
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study
Autorzy:
Oramus, P.
Chmielewski, T.
Kuczek, T.
Piasecki, W.
Szewczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/140943.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arc modelling
overvoltages studies
EMTP-ATP program
transients analysis
Opis:
Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 441-458
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on ferroresonance due to power transformer energization in high voltage 400 kV transmission grid
Autorzy:
Polewaczyk, Mateusz
Robak, Sylwester
Szewczyk, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/141509.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ferroresonance
high voltage
Poincaré map
power system transients
PSCAD
Opis:
This paper presents a study on ferroresonance occurring in a high voltage 400 kV transmission grid due to energization of power transformer under no-load conditions. The system scenarios analyzed in the present paper are considered as critical for development and modernization plans as currently announced by the national grid operator in Poland. The PSCAD simulation model was developed and applied for several study cases of a system with double-circuit arrangement of a transmission line. It is shown that the ferroresonant oscillations can be initiated by two-phase switching operation of a line circuit breaker. The impact of the double-circuit length on the ferroresonance mode and severity is demonstrated with the use of the Poincaré map analysis and Short Time Fourier Transform. It is demonstrated that the length of the transmission line that is mutually coupled in the double-circuit arrangement has a significant impact on the ferroresonance occurrence and on its mode. As the ferroresonance can pose severe threat to the power system components due to the severe overvoltage and overcurrent oscillations, the analysis presented in this paper demonstrates the necessity of the ferroresonance analyses for any re-designed transmission system.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 771-786
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling transients in MV resonantly grounded industrial grid during single line to ground faults
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/377060.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical grid
grounding methods
transients overvoltage
transient intermittent faults
Opis:
Medium voltage distribution power grids mostly operate with ungrounded neutral points of transformer. The philosophy about these power supply systems based on the assumption that the electrical grid is more reliable. However the practice of operation showed that currents of single phase or multiple faults to ground depend mostly on the earth capacitances of cables connected to power grid and configuration and structure in relation to the main substation buses. Moreover, this kind of arcing ground faults on the ungrounded system causes transient overvoltages several times than nominal value. In the consequence, it may be dangerous for the electrical devices connected to the power system. The article focuses on the transient impact the equipment insulation due to faults in the middle voltage industrial grid with adjustable speed drives. The examination results of transient voltages across the system was presented. The Matlab/ Simulink Software was used to modeling system behavior during intermittent faults.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 98; 65-75
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control of operability of Peltier modules in cooling systems based on the analysis of transient operating modes
Autorzy:
Kuzichkin, Oleg Rudolfovich
Konstantinov, Igor Sergeevich
Vasilyev, Gleb Sergeevich
Surzhik, Dmitry Igorevich
Powiązania:
https://bibliotekanauki.pl/articles/1845461.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermoelectric system
agriculture
complex
transients
peltier effect
identification algorithms
Opis:
The paper is devoted to the control of operability of Peltier modules based on the analysis of transient modes of their operation. Advantages of using low-power thermoelectric modules for the development of thermoelectric plants with adaptive control systems for the needs of the agricultural complex, which significantly reduce their cost characteristics, are shown. The problem of using the stationary mode of their operation, associated with the low efficiency of the modules, as well as the dynamic mode, associated with the presence of transient processes, is indicated. It is noted that overcoming this problem requires solution of the task of automation of reliability providing the well-known approaches to its solution are shown, for which the key advantages and disadvantages are given. An approach is proposed to complex control of the operability and quality of thermoelectric modules during their expluatation in three components of the physical process of thermoelectric conversion (Peltier thermoelectric effect, electrical and thermal transfer phenomena) by analyzing transients in the system based on identification algorithms. To justify it, the necessary equations and mathematical relations are given. Aprobating of the proposed approach was carried out experimentally by determining the time constants for operable and defective commercially available modules and showed its significant advantages over the standard verification procedure.
Źródło:
Archives of Thermodynamics; 2021, 42, 2; 31-42
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Rho-associated kinase inhibition on actin cytoskeleton structure and calcium response in glioma C6 cells
Autorzy:
Targos, Berenika
Pomorski, Paweł
Krzemiński, Patryk
Barańska, Jolanta
Rędowicz, Maria
Kłopocka, Wanda
Powiązania:
https://bibliotekanauki.pl/articles/1041182.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
glioma C6
actin cytoskeleton
RhoA
ROCK
calcium transients
Opis:
The role of actin cytoskeleton functional state in glioma C6 cell morphology and calcium signaling was investigated through modification of myosin II activity by blocking Rho-associated kinase with the specific inhibitor Y-27632. Treatment of glioma C6 cells with ROCK inhibitor resulted in actin cytoskeleton reorganization and also in the changed shape and distribution of mitochondria. Changes in the distribution of ER, the main calcium store in glioma C6 cells, were not visible. The inhibition of myosin II activity influences the first phase of calcium signaling evoked by agonist, and both phases of thapsigargin-evoked calcium response. We suggest that the observed increase in Ca2+ release from intracellular stores induced by IP3 formation as well as inhibition of SERCA ATPase is at least in part related to severely affected mitochondria. Enhancement of capacitative calcium entry evoked by thapsigargin is probably associated with the reorganization of the acto-myosin II system. ATP-induced calcium response presents no changes in the second phase. We observed that ATP stimulation of Y-27632 pretreated cells leads to immediate morphological rearrangement of glioma C6 cells. It is a consequence of actin cytoskeleton reorganization: formation of stress fibers and relocation of phosphorylated myosin II to actin filaments. It seems that the agonist-evoked strong calcium signal may be sufficient for myosin II activation and the stress fiber organization. This is the first work showing the dependence between the functional state of the acto-myosin II system and calcium signaling stressing the reversible character of this relationship.
Źródło:
Acta Biochimica Polonica; 2006, 53, 4; 825-831
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Transients in a 4-Level Flying Capacitor Converter: Time Domain Approach. Part 2: Small Normalised Voltage Command
Autorzy:
Reznikov, Boris
Ruderman, Alex
Galanina, Valentina
Powiązania:
https://bibliotekanauki.pl/articles/1193863.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
4-level DC–DC converter
flying capacitor
natural balancing
transients
Opis:
A 4-level flying capacitor converter (FCC) operation is considered on a base of discrete state-space model. A transition matrix is obtained for a pulse width modulation (PWM) period for small normalised voltage command values [0, 1/3]. The transition matrix elements are expanded into power series by small parameters. The matrix eigenvalues are presented in the form of power series as well. Six separate transients are constructed for six possible initial FCC states on a PWM period. Inductor current and capacitors’ voltage transients are found for the voltage source power-up as the arithmetic average of the six separate transients. Finally, the discrete solutions are replaced by equivalent continuous ones. Simple and accurate formulas for inductor current and capacitors’ voltage transients demonstrate good agreement with simulation results.
Źródło:
Power Electronics and Drives; 2020, 5, 40; 41-57
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Transients in a 4-Level Flying Capacitor Converter: Time Domain Approach. Part 1: Large Normalised Voltage Command
Autorzy:
Reznikov, Boris
Ruderman, Alex
Galanina, Valentina
Powiązania:
https://bibliotekanauki.pl/articles/1193906.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
4-level DC-DC converter
flying capacitor
natural balancing
transients
Opis:
A 4-level flying capacitor converter (FCC) operation is considered on a base of discrete state-space model. A transition matrix is obtained for a pulse width modulation (PWM) period for large normalised voltage command values [1/3, 1). The transition matrix elements are expanded into power series by small parameters. The matrix eigenvalues are presented in the form of power series as well. Six separate transients are constructed for six possible initial FCC states on a PWM period. Inductor current and capacitors’ voltage transients are found for the voltage source power-up as the arithmetic average of the six separate transients. Finally, the discrete solutions are replaced by equivalent continuous ones. Simple and accurate formulas for inductor current and capacitors’ voltage transients demonstrate good agreement with simulation results.
Źródło:
Power Electronics and Drives; 2020, 5, 40; 27-40
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vibration transients of reservoir-pipe-valve system caused by water hammer
Autorzy:
Miao, Yang
Jiang, Yuncheng
Qiu, Zaihui
Pan, Jun
Wang, Lu
Han, Zhenrong
Li, Kun
Zhang, Li
Zhang, Xiaolu
Powiązania:
https://bibliotekanauki.pl/articles/1839616.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
reservoir-pipe-valve system (RPV system)
water hammer
vibration
transients
Opis:
A severe oscillation, accompanied with an abnormal “click” sound, of a fuel feeding pipe system during valve closing, when the feeding flowrate reaches a certain value, is observed experimentally. A fluctuation model in which stiffness and damping coefficients of the vibration system are time varying is proposed. Each coefficient is composed of two parts, one of which is constant and the other is time varying. Based on this model, simulation transients of the vibration displacement, velocity and pressure in the pipe are presented. Simulations of the pressure transients are compared with experimental data detected by pressure transducer, which shows that both have fluctuations in the transient process at a large flowrate.
Źródło:
Journal of Theoretical and Applied Mechanics; 2020, 58, 4; 1037-1048
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the stator inductances of the expanded Park model and an approach on parameter identification using the evolution strategy
Autorzy:
Schmuelling, Ch.
Kreischer, Ch.
Gołebiowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141147.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
evolution strategy
FEM
Park equations
Park theory
synchronous machines
transients
Opis:
Commonly, the Park model is used to calculate transients or steady-state operations of synchronous machines. The expanded Park theory derives the Park equations from the phase-domain model of the synchronous machine by the use of transformations. Thereby, several hypothesis are made, which are under investigation in this article in respect to the main inductances of two different types of synchronous machines. It is shown, that the derivation of the Park equations from the phase-domain model does not lead to constant inductances, as it is usually assumed for these equations. Nevertheless the Park model is the most common analytic model of synchronous machines. Therefore, in the second part of this article a method using the evolution strategy is shown to obtain the parameters of the Park model.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 585-599
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of different methods for excitation of synchronous machines
Autorzy:
Schmuelling, S.
Kreischer, Ch.
Gołȩbiowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1367718.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
AC machines
Brushless machines
Electromagnetic transients
Excitation system
Power system simulation
Opis:
The energy turnaround in Germany leads to new operating conditions for small and medium synchronous generators. Since the electricity generation through renewable energy sources, such as wind or photovoltaic, is highly volatile, generators have to run up from standstill into rated operation within several minutes. Hence, it is necessary to compensate a lack of electricity generation caused by wrong weather forecasts. Usually, gas turbine systems provide this possibility. The generator is used as a starter engine due to the connection to a frequency inverter. The excitation current is often provided by static excitation systems. Thus, it is possible to start from standstill and run up the drive until the gas turbine is able to generate a positive torque. A new excitation concept, based on an induction machine with a 3-phase rotor winding, is able to provide an excitation current at 0 rpm and eliminates the need for brushes. To verify the applicability for power systems, both systems are compared under different aspects. The control of the excitation current at different speeds and the possibility to settle shaft oscillations after electrical faults are aspects researched in the paper at hand. A power system simulation is performed with a synchronous machine connected to a grid. Both excitation systems are modeled by equivalent circuit diagrams in Matlab Simscape.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 3, 107; 89-93
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accidents of loss of flow for the ETTR-2 reactor: deterministic analysis
Autorzy:
El-Messiry, M.
Powiązania:
https://bibliotekanauki.pl/articles/146728.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
design base accidents
LOFA
loss of flow
pump coastdown
reactor transients
Opis:
The main objective for reactor safety is to keep the fuel in a thermally safe condition with adequate safety margins during all operational modes (normal-abnormal and accidental states). To achieve this purpose an accident analysis of different design base accident (DBA) as loss of flow accident (LOFA), is required for assessing reactor safety. The present work concerns this transients applied to Egypt Test and Research Reactor ETRR-2 (new reactor). An accident analysis code FLOWTR is developed to investigate the thermal behaviour of the core during such flow transients. The active core is simulated by two channels: 1 - hot channel (HC), and 2 - average channel (AC) representing the remainder of the core. Each channel is divided into four axial sections. The external loop, core plene, and core chimney are simulated by different dynamic lumps. The code includes modules for pump coast down, flow regimes, decay heat, temperature distributions, and feedback coefficients. FLOWTR is verified against results from RETRAN code, THERMIC code and commissioning tests for null transient case. The comparison shows a good agreement. The study indicates that for LOFA transients, provided the scram system is available, the core is shutdown safely by low flow signal (496.6 kg/s) at 1.4 s where the HC temperature reaches the maximum value of 45.64°C after shutdown. On the other hand, if the scram system is unavailable, and at t=47.33 s, the core flow decreases to 67.41 kg/s, the HC temperature increases to 164.02°C, and the HC clad surface heat flux exceeds its critical value of 400.00 W/cm2 resulting from the fuel burnout.
Źródło:
Nukleonika; 2000, 45, 4; 229-233
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new closed loop speed control strategy for a vector controlled three-phase induction motor drive
Autorzy:
Tripathi, A.
Dey, A.
Dwivedi, B.
Singh, B.
Chandra, D.
Powiązania:
https://bibliotekanauki.pl/articles/262777.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
space vector modulation
VSI
induction motor model
transients
steady state value
Opis:
This paper presents a completely mathematical equations based model on control of torque and speed of a three-phase indirect vector controlled VSI fed cage induction motor drive that is controlled through the space vector modulated method. This enables a wide range of acceptability of the model for various values of load and for various types and ratings of induction motors. The uniqueness of the model lies in the fact that the deviations in the torque and speed on sudden application of reference step change in speed values are minimum i.e. when any sudden change in the speed reference is desired, the speed and torque waveforms reveal that the time taken in coming back to their final steady state values is very less and the motor overcomes the perturbation with negligible transients. The same is verified through the simulated results.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 1; 67-72
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the Interaction Between Theory, Experiments, and Simulation in Developing Practical Learning Control Algorithms
Autorzy:
Longman, R. W.
Powiązania:
https://bibliotekanauki.pl/articles/908249.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
automatyka
robotyka
iterative learning control
ILC
2D systems
learning transients
Opis:
Iterative learning control (ILC) develops controllers that iteratively adjust the command to a feedback control system in order to converge to zero tracking error following a specific desired trajectory. Unlike optimal control and other control methods, the iterations are made using the real world in place of a computer model. If desired, the learning process can be conducted both in the time domain during each iteration and in repetitions, making ILC a 2D system. Because ILC iterates with the real world, and aims for zero error, the field pushes the limits of theory, modeling, and simulation, to predict the behavior when applied in the real world. It is the thesis of this paper that in order to make significant progress in this field it is essential that the research effort employ a coordinated simultaneous synergistic effort involving theory, experiments, and serious simulations. Otherwise, one very easily expends effort on something that seems fundamental from the theoretical perspective, but in fact has very little relevance to the performance in real world applications.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2003, 13, 1; 101-111
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of transient flows in a hydraulic system with a long liquid line
Symulacja przepływów przejściowych w układzie hydraulicznym z hydrauliczną linią długą
Autorzy:
Zarzycki, Z.
Kudźma, S.
Kudźma, Z.
Stosiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/281500.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
układy hydrauliczne
pulsacje pomp
uderzenia hydrauliczne
unsteady pipe flow
transients
pulsation of pump
Opis:
The paper presents the problem of modelling and simulation of transients phenomena in hydraulic systems with long liquid lines. The unsteady resistance model is used to describe the unsteady liquid pipe flow. The wall shear stress at the pipe wall is expressed by means of the convolution of acceleration and a weighting function which depends on the (laminar or turbulent) character of the flow. The results of numerical simulation are presented for the waterhammer effect, which is caused by a sudden shift of the hydraulic directional control valve. The following cases of the system supply are considered: the first, with a constant delivery rate of the pump and the second, which additionally considers pulsation of the delivery of the pump. Computer simulations are compared with results of experiments. They are found to be very consistent in the case with the variable rate of the pump delivery taken into accent.
Artykuł przedstawia zagadnienie modelowania i symulacji zjawisk przejściowych w układach hydraulicznych z hydrauliczną linią długą. Wykorzystano model tarcia niestacjonarnego do opisu niestacjonarnego przepływu w przewodzie. Naprężenia ścinające na ściankach przewodów są określone za pomocą przyspieszenia i finkcji wagi, która zależy od charakteru przepływu (uwarstwiony, turbulentny). Rezultaty symulacji numerycznych są prezentowane dla uderzenia hydraulicznego, które spowodowane jest poprzez nagłe przesterowanie rozdzielacza. Rozpatrywane są dwa przypadki: pierwszy - gdy układ zasilający podaje stałą wartość natężenia przepływu, drugi uwzględniający pulsację wydajności pompy wyporowej. Symulacje komputerowe są porównane z wynikami badań eksperymentalnych. Wykazano dużą zgodność symulacji komputerowych uwzględniających pulsację wydajności pompy z wynikami eksperymentu.
Źródło:
Journal of Theoretical and Applied Mechanics; 2007, 45, 4; 853-871
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical criterion for the duration of non-chaotic transients in ODEs
Autorzy:
Szczebiot, Ryszard
Kaczyński, Roman
Gołdyn, Leszek
Powiązania:
https://bibliotekanauki.pl/articles/2204683.pdf
Data publikacji:
2022
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
numerical criterion
non-chaotic transients
limit cycle
ODEs systems
Van der Pol oscillator
Opis:
The paper proposes an original numerical criterion for the duration analysis of non-chaotic transients based on the Euclidean norm of a properly defined vector. For this purpose, transient trajectories, prior to their entering a small neighbourhood of the limit cycle, are used. The vector has been defined with its components constituting the lengths of the sections, which connect the origin of the coordinate system with appropriately determined transient trajectory points. The norm of the vector for the analysis of non-chaotic transients has also been applied. As an assessment criterion of transients, the convergence of the norm to small neighbourhood of the limit cycle with the assumed accuracy is used. The paper also provides examples of the application of this criterion to the Van der Pol oscillators in the case of periodic oscillations.
Źródło:
Acta Mechanica et Automatica; 2022, 16, 4; 388--392
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydraulic transients analysis in pipe networks by the method of characteristics (MOC)
Autorzy:
Wichowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/240954.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
hydraulic transients
method of characteristics
single pipe
experimental measurement
pipe networks
numerical simulations
Opis:
The paper presents results of an experimental and theoretical study of the hydraulic transients in straight pipes and numerical simulations of unsteady flow in pipe networks. A mathematical model consists of a set of partial differential equations of hyperbolic type, which have been transformed by the method of characteristics into ordinary differential equations which are solved by the predictor-corrector method. Experimental tests have been performed, in order to examine the hydraulic transients phenomenon, in a single straight steel pipe. The experiments were carried out in the hydraulic laboratory of the Institute of Water Supply and Water Engineering, Environmental Engineering Faculty, Warsaw University of Technology. The numerical results show that the presented one dimensional model for a single pipe correctly describes the phenomenon since there is a good agreement with experimental maximum and minimum oscillations. In the paper, selected exemplary equations in a difference form for the pipe networks are also presented. One calculation example is given relating to the complex water-pipe network consisting of 17 loops, 48 pipelines and 33 nodes, supplied by two independent sources. Water-hammer throughout the whole pipeline network was caused by closing the gate valve at mid-point of one selected pipe. The results of the numerical calculations are presented in graphic form with respect to the final cross-sections of pipes.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2006, 53, 3; 267-291
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical calculations of surges caused by direct lightning strike to underground intrusion detection system
Autorzy:
Aniserowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/200287.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lightning
transients
overvoltages
analytical modeling
underground cable
błyskawica
transjenty
przepięcia
modelowanie analityczne
kabel podziemny
Opis:
The paper presents an analysis of overvoltages caused by a direct lightning strike in intrusion detection system equipped with underground radiating cable sensors. Waveforms of currents and voltages in the system components are calculated using analytical formulas basing on a transmission-line model in the frequency domain. The time-domain waveforms are computed using the inverse fast Fourier transform (IFFT). Three network configurations of the intrusion detection system are analyzed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 2; 263-270
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transformer Modelling for the Frequency and Transient Analyses, with Non-Uniform Inductance Emulating the Inter-Turn Magnetic Coupling
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262677.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
distributed parameter circuits
frequency response
modeling
power system transients
power transformers
resonance
non-uniform
Opis:
A new procedure for analyzing power transformer windings with location-dependent circuit parameters, such as the series inductance, is presented. This dependence is introduced in order to take the inter-turn mutual inductive coupling into consideration. It can be expressed either by analytical expressions or even in a tabulated form. The paper addresses both the frequency and time domain analyses. They are based on replacing the winding by an adequate number of equivalent cascade connected two-ports. In contrast to the usual practice of applying the simple medium line representation, each of these two-ports is treated as a long transmission line. Their A, B, C, D generalized circuit constants will be therefore generally location-and frequency-dependent. The analyses will be conducted in the complex s-domain. The corresponding time-domain results can then be obtained by applying a numerical inverse Laplace transform. Expressions for the winding’s input impedance with different treatments of the transformer’s neutral point will be derived for any assumed number of the equivalent two-ports. Results pertinent to the frequency characteristics including the resonance frequencies are presented. The paper also describes the winding’s transient response to the application of two standard voltage stimuli. The suggested approach is validated by its application to a case study for which an analytical closed-form solution is available. The analysis of windings exhibiting nonuniformities in more than one equivalent.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2014, 17, 1; 1-11
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Low Frequency Transients in Power Transformers and Some Protection-Related Issues
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/1203944.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
transformer cores
inrush current
protection
transients
modeling
equivalent circuit
low frequency
nonlinear model
simulation
Opis:
This paper presents typical results for the non-linear low frequency transients following the energization of power transformers. The three operating conditions of no-load, full-load and internal faults are considered. A direct analytical procedure is applied for solving the corresponding set of differential equations describing the transformers equivalent circuit. The core representation is based on the use of curve fitting applied to their magnetization curves. The results include plots versus time for the supply current, the core flux, the magnetizing current as well as the internal induced voltage. Moreover, graphs for the hysteresis loops relating the instantaneous values of both the excitation current and the core flux are given. An approach is also presented for the numerical determination of the amplitudes of the different harmonics existing in any of these signals utilizing the corresponding equidistant samples. As examples, the DC offset as well as harmonics up to the fourth order are considered. It is shown that several useful features can be extracted from the results in both the time and harmonic domains that can assist in differentiating between overcurrents resulting from short-circuits or inrush phenomena.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2014, 17, 2; 9-16
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczenia elektromagnetyczne przetwornika o ruchu złożonym opartego na wspólnym obwodzie magnetycznym
Analysis of the Dynamic and Stationary States of a Car Starter with Permanent Magnet Motor
Autorzy:
Ciurys, M.
Dudzikowski, I.
Powiązania:
https://bibliotekanauki.pl/articles/1368124.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
rozruszniki samochodowe
magnesy trwałe
przebiegi czasowe
electrical machines
car starters
permanent magnets
transients
Opis:
Using field – circuit method transients of the electric and magnetic quantities of the developed car starter motor with ferrite magnets were determined at dynamic and stationary operating conditions. These results were used, in the developed mathematical model, algorithm and software, to determine mechanical and electrical transient in the system: battery – electrical motor – mechanical transmissions – combustion engine. Transients of the analysed electromechanical system were determined taking into account the variations of inertia, the variations of the load torque generated by combustion engine and the influence of the temperature on the battery parameters, magnets parameters and load torque generated by the combustion engine. Electromechanical characteristics of the car starter were determined.
Metodą polowo-obwodową wyznaczono przebiegi czasowe wielkości elektrycznych i magnetycznych w opracowanym silniku rozrusznika samochodowego z magnesami ferrytowymi w dynamicznych i ustalonych stanach pracy. Wyniki te wykorzystano w opracowanym modelu matematycznym, algorytmie i programie do wyznaczania przebiegów wielkości mechanicznych i elektrycznych w układzie: akumulator – silnik elektryczny – przekładnie mechaniczne – silnik spalinowy. Wyznaczone przebiegi czasowe w analizowanym układzie elektromechanicznym uwzględniają zmienność momentu bezwładności i zmienność momentu obciążenia generowanego przez silnik spalinowy oraz wpływ temperatury na parametry akumulatora, parametry magnesów i na moment obciążenia generowany przez silnik spalinowy. Wyznaczono charakterystyki elektromechaniczne rozrusznika.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 3, 100/1; 141-146
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fuel feed to diesel at a start regime
Autorzy:
Fedyanov, E.
Slavuckiy, V.
Kanygin, Z.
Powiązania:
https://bibliotekanauki.pl/articles/246126.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
starting duty
features of process of giving
nozzle valve lifting
injection pressure
transients
cyclic fuel delivery
Opis:
Some factors defining starting properties of diesel engines are considered. Features of process of fuel feed on a starting mode are analyzed. Basic possibility of steering by processes of mixture forming and combustion is proved at a small speed of a crankshaft. Developed a design procedure of process of fuel feed in a diesel engine at a start regime. On the basis of the theory of transients in a fuel system, the reasons of deterioration of indicators of fuel feed process are explained at a start regime of diesel engine. Possibilities of a method of increase of initial pressure in a delivery highway by prostrating scrolling of a crankshaft with idle spray jets are investigated. The method of intensification of fuel feed process patented by authors used in diesel engine at a start regime. The results of numerical experiments confirming improvement of indicators of process of injection at high-speed speeding up of the pump of a high pressure are resulted: Increase maximum and an average pressure, cutting-down of duration of fuel feed process. The paper concentrates on possibility of improving fuel fed process at the starting regime by means of high speed forcing the fuel pump and the initial pressure rising by an earlier camshaft rotation with out of work injectors.
Źródło:
Journal of KONES; 2009, 16, 1; 111-116
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics simulations of the electrodynamic railgun different constructions and their measurement verification
Autorzy:
Piekielny, Paweł
Tomczuk, Bronisław
Waindok, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/27309948.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
3D field analysis
analysis of transients
analytical models
electrodynamic accelerator
experimental verification
field-circuit modeling
projectile velocity
Opis:
Dynamic characteristics for three types of railgun constructions were simulated and measured in this work. The simplest construction is the iron-less (IL) railgun, while the two other ones (IC and ICPM) have an iron-core. The iron-core permanent magnet (ICPM) railgun additionally has permanent magnets. To compare their characteristics, similar dimensions of the rails and iron cores were adopted, and the same power supply system was used. Numerical magnetic field analyses and our analytical models have been used to determine the electromagnetic parameters. They were verified experimentally. The transient states of the railguns were studied with our field-circuit mathematical model, and their results were also verified by experiments.
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 951--969
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients in Transformers with Non-Uniform Inductance and Capacitance Distributions
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262695.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
distributed parameter circuits
electromagnetic transients
integro-differential equations
modeling
mutual parameters
non-uniform
power transformers
transient response
winding
Opis:
The electromagnetic transients in transformer windings exhibiting location–dependent inductances and capacitances are investigated in the time domain. Analytical functions describing this dependence are assumed and incorporated in the two integro–differential equations governing the transient voltage and current distributions. The boundary conditions are available from the source initiating the transients and the winding’s end termination. A numerical procedure is applied in order to get frequency domain solutions for the voltage and current in the form of Interpolating and Parametric Functions. The numerical Laplace inversion is then applied to these s–domain expressions. Results pertinent to transients initiated by step- and double-exponential impulse sources are presented and discussed. All possible transformers’ neutral connections are considered. The possible error introduced by neglecting either or both of the inductance and capacitance non-uniformities is addressed. Results indicate that the main error is attributed to neglecting the inductance non-uniformity, whereas the impact of the capacitance non-uniformity is relatively small. In most cases, the winding’s copper and insulation losses have a small effect on the transient response.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2017, 20, 1; 7-14
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients under energizing multiple power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97327.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
C–type filter
Static Var Compensator
transient overcurrent
transient overvoltage
dynamic overcurrent
dynamic overvoltage
switching transients
Opis:
The practice of operating reactive power compensation systems involving passive multiple filter circuits (FC) configured by single–tuned filters has shown, that it’s energizing can cause damage of the filter components. Impact of feasible FC configurations, including FC with a C–type filter, on switching overvoltages and overcurrents under the harmonic filters energizing were analyzed. Influence of the filters tuning on transient behavior has been shown. The transient analysis has been carried out by simulating of the FC within Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 89-100
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Program PSCAD/EMTDC jako wygodne narzędzie do modelowania linii napowietrznych
Modelling of Overhead Lines by the PSCAD/EMTDC
Autorzy:
Smolarczyk, A.
Chmielak, W.
Powiązania:
https://bibliotekanauki.pl/articles/158669.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
linie napowietrzne
stany przejściowe
modelowanie
PSCAD/EMTDC
overhead lines
transients in power systems
power system modelling
PSCAD/EMTDC software
Opis:
W artykule opisano jeden z programów do symulacji zjawisk dynamicznych występujących w systemie elektroenergetycznym. Program o nazwie PSCAD/EMTDC jest powszechnie używany do modelowania fragmentów systemu elektroenergetycznego i zjawisk w nich występujących. Przedstawiono dostępne w programie modele linii napowietrznych, które mogą zostać wykorzystane do modelowania takich sytuacji jak stany łączeniowe (załączenia, wyłączenia) linii, zwarcia w linii. W programie linie napowietrzne można zamodelować ręcznie za pomocą elementów pasywnych typu R, L, C, z wykorzystaniem gotowych czwórników typu PI, za pomocą gotowych modeli typu Bergeron Model, Frequency Dependent (Mode) Model, Frequency Dependent (Phase) Model. Pokazano przykładowy sposób zamodelowania linii WN 110 kV z wykorzystaniem słupów kratowych typu B2 za pomocą modelu typu Frequency Dependent (Phase) Model.
The article describes one of the programs for the simulation of dynamic phenomena occurring in the power system. The program called PSCAD/EMTDC is commonly used to model the parts of the power system and phenomena occurring in them. The models of the overhead lines that can be used for modelling situations such as switching states of the line, short-circuit line have been presented. Overhead lines can be manually modelled using passive R, L, C elements by using prepared PI section elements, using prepared Bergeron Model, Frequency Dependent (Mode) Model, Frequency Dependent (Phase) Model. It was shown how to model a high-voltage line 110 kV with the use of type B2 towers by the Frequency Dependent (Phase) Model.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 272; 31-48
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozrusznik samochodowy z bezszczotkowym silnikiem prądu stałego
Car starter with brushless direct current motor
Autorzy:
Ciurys, M.
Dudzikowski, I.
Powiązania:
https://bibliotekanauki.pl/articles/320357.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
rozruszniki samochodowe
silniki bezszczotkowe
magnesy trwałe
obliczenia
stany dynamiczne
car starters
brushless direct current motors
permanent magnets
computations
transients
Opis:
Opracowano model matematyczny, algorytm i program obliczeń przebiegów czasowych wielkości elektrycznych i mechanicznych w układzie: akumulator - rozrusznik samochodowy z bezszczotkowym silnikiem prądu stałego (BLDC) - silnik spalinowy. Opracowany model matematyczny, algorytm i program obliczeń uwzględniają, m.in.: zmienność momentu bezwładności układu korbowego silnika spalinowego, zmienność momentu kompresji i dekompresji gazów w cylindrach oraz zależność momentu tarcia silnika spalinowego od prędkości chwilowej wału korbowego. Obliczono przebiegi czasowe wielkości elektrycznych i mechanicznych w analizowanym układzie.
A mathematical model, algorithm and program for calculations of electrical and mechanical quantities transients in the system: accumulator — starter with brushless direct current motor - combustion engine were developed (Figs 1, 2, 3). The developed mathematical model, computational algorithm and program take account of the combustion engine crankshaft moment of inertia variations as well as the variations of both the compression and decompression torque in the cylinders and the combustion engine friction torque dependence on the instantaneous crankshaft speed. Transients of electrical and mechanical quantities in the analysed system were calculated (Figs 4, 5).
Źródło:
Elektrotechnika i Elektronika; 2006, 25, 2; 129-132
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Transient Performance of Partially-Undergrounded Overhead Lines in the Presence of Corona
Autorzy:
Saied, Mohamed M.
Powiązania:
https://bibliotekanauki.pl/articles/262791.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
distributed parameter circuits
non-uniform lines
power transmission lines
line modeling
transients
power networks
mixed
overhead-cable lines
partial undergrounding
distributions
mathematica
Opis:
The paper presents a method for investigating the electromagnetic transients of partially under-grounded high voltage overhead transmission lines in the presence of corona. It is based on a time domain model in which the corona is simulated by distributed voltage-dependent shunt current sources. The line segments and the inserted cable section are represented by a single equivalent transmission element having location-dependent circuit parameters per unit length. The numerical solution of the resulting set of differential equations yields the distributions of the voltage, the longitudinal current and the shunt corona current (per unit length) as functions of location and time. The presented two-, three-dimensional and contour plots proved to be helpful in discussing these distributions and in identifying any eventual current and/or voltage concentrations. The developed computer code in Mathematica can handle any time waveform of the source initiating the transients, any line termination as well as any lengths of the overhead line and cable section.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2019, 21, 1; 1-8
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ charakterystyk eksploatacyjnych sieci przemysłowych na dobór parametrów filtrów harmonicznych
Impact of industrial network operating characteristics on the harmonic filter parameters sizing
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/268765.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
filtr wyższych harmonicznych
stany ustalone
stany przejściowe
bateria kondensatora
dławik filtrujący
harmonic filter
steady state
transients
capacitor bank
air-core filter reactor
Opis:
Układy kompensacji mocy biernej oraz filtracji, oparte na kondensatorach znajdują powszechne zastosowanie w praktycznych rozwiązaniach systemów przemysłowych. Ich parametry znamionowe wyznaczane są wyłącznie w oparciu o harmoniczne prądów oraz napięć w stanach ustalonych, niemniej jednak tyczy się to głównie jednostek filtrujących o prostej topologii. Stąd, mając na uwadze bardziej złożone układy w większości przypadków istniejących lub nowoprojektowanych obiektów wymaga się, aby analizowane układy były dostosowane do pracy zarówno w warunkach ustalonych jak i przejściowych. Korzystając ze standardów oraz norm, w artykule omówiono procedurę doboru parametrów baterii kondensatorów oraz dławików układów filtrujących z pozycji ich bezawaryjnej pracy w elektrycznych sieciach przemysłowych. Zaproponowana metoda ma wspomóż działania projektowe filtrów harmonicznych.
The application of harmonic filter circuit based on power capacitor banks are widely used in practical solutions in industrial systems. The component ratings of these units are often specified based solely on a combination of steady state fundamental and harmonic voltages and currents. Although, this may be adequate in single-tuned or single branch units and method may not properly rate the components for more complex applications such as multiple, single-tuned harmonic filter circuits in compensated installations. Thus, in the most cases of commonly used or newly designed circuits are required to be adapted to operate as well in steady state and transients conditions. Using the exsisting Standards, the article propose a method for determining equipment ratings parameters of the capacitor banks and air-core filter reactors according to malfunctions. The study illustrated in this paper will be used to support and improve harmonic filter realiability and design. It is hoped that ideas will be a resource for a future filter application guide being contemplated by the capacitor subcommittee.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 47-51
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stany nieustalone towarzyszące pomiarowi impedancji pętli zwarcia w obwodach wyjściowych zasilaczy bezprzerwowych UPS
Transient states associating loop impedance measurement in the output line of UPS power supplies
Autorzy:
Olesz, M.
Katarzyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/266602.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
stany nieustalone
zasilacze bezprzerwowe
pomiary jakości energii elektrycznej
impedancja pętli zwarcia
transients
uninterruptible power supplies
power quality measurements
fault loop impedance
Opis:
W pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem wielokanałowym potwierdziły poprawność danych uzyskiwanych w celu określenia reakcji zasilacza na zaburzenia występujące na wejściu i wyjściu urządzenia. W pracy analizowano wyniki pomiarów impedancji pętli zwarciowej zmierzone przyrządem wymuszającym poziomy prądu zwarciowego na linii zasilającej odbiorniki energii elektrycznej we wszystkich stanach pracy zasilacza, a następnie porównywano je z wynikami obliczeń przeprowadzonych na uzyskanych przebiegach prądu i napięcia.
The paper presents the methodology and the results of transient measurement in on-line Uninterruptable Power Supply (UPS). There were two power quality measurement instruments (synchronised with time) used for registering the events in UPS input and output. The recorders compress the obtained measurement data, which may introduce additional measurement errors of measured values, i.e. voltage and current. Additional registrations with a multi-channel oscilloscope confirmed the correctness of the obtained data in order to determine the reaction of the UPS to the disturbances occurring in UPS input and output. The work analysed the results of loop impedance, measured by a meter that forces short-circuit current in the line supplying electric load, in all states of the UPS, and then they were compared with the results of calculations carried out on the obtained current and voltage waveforms. The measurement of fault loop impedance in UPS output line should be performed in active static switch (bypass mode), because UPS will operate in this mode after switching from inverter operation due to high current forcing during a short circuit in the UPS output. Measurement of fault loop impedance in UPS output circuits, when it is in AC-DC-AC double conversion mode, may result with loop impedance overstating by meters, which in turn limits recognition of the tested installation as safe from the protection against electric shock by automatic power off point of view. The values of calculated loop impedance at forced high current, i.e. 160 A in the UPS output, when it is respectively in the manual bypass and static switch mode, are 4% and 2.5% lower than the ones presented by meter after measure by forcing high current. Differences in impedance of the static switch and manual bypass UPS mode can be the basis for the estimation of the thyristor impedance. Estimation of direct measurement results with 14.6 m, and according to the calculation of recorded transients it is about 16.1 m.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 61; 57-60
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time and electric energy losses minimization in speed control of induction motors
Autorzy:
Kawecki, L.
Niewierowicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/205536.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
optymalizacja
sterowanie optymalne
zasada maksimum
electric energy losses minimization
electromagnetic transients
induction motors
machine control
optimal control
optimal frequency starting
speed control
Opis:
The paper presents a method for solving the problem of the simultaneous time and electric energy losses minimization during the frequency speed control of induction motors with the electromagnetic transients. To solve this vector optimization problem, the optimization index in the form of linear combination of the scalar indexes is assumed and the Pontryagin maximum principle is used. Examples of solution for two cases of optimal frequency starting of two induction motors are presented.
Źródło:
Control and Cybernetics; 1999, 28, 2; 331-353
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A coupled field-circuit model of a 5-phase permanent magnet tubular linear motor
Autorzy:
Tomczuk, B.
Waindok, A.
Powiązania:
https://bibliotekanauki.pl/articles/141318.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
silnik synchroniczny liniowy
magnes trwały
PMLSM
metoda polowo-obwodowa
symulacja
parametry sterowania
permanent magnet linear synchronous motors
field-circuit method
simulation of the transients
control parameters
Opis:
A method for modeling of the dynamics characteristics for a 5-phase permanent magnet tubular linear motor (PMTLM) is presented. Its electromagnetic nonlinear field analysis with finite element method (FEM) has been coupled with the circuit model. The calculation model includes the equations for electrical circuits and mechanical quantities as well. They have been obtained using Lagrange's method. The calculated and measured waves of the mover position have been compared for several values of the excitation current. This comparison yields a good agreement. Presented calculation model is very useful in designing and optimization of the PMTLM and in the calculation of the parameters for the control algorithms intended for such a type of actuators.
Źródło:
Archives of Electrical Engineering; 2011, 60, 1; 5-14
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel power quality data analysis and reporting framework for wide-area system of registration and processing of power quality data
Autorzy:
Rezmer, J.
Leonowicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/136208.pdf
Data publikacji:
2015
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
power quality
faults
power distribution
reliability
power system restoration
power system transients
relational databases
distributed generation
voltage dips
GIS
data visualization
data analysis
localization of disturbances
Opis:
This paper presents a novel method for data analysis and visualization, including real-time visual monitoring and proposal for combined area PQ indices on the example of the developed and operational comprehensive system of registration, archiving and data processing for the wide-area monitoring of power quality in a separated part of real power grid with distributed renewable generation. Real case studies related to power quality disturbances are presented.
Źródło:
Transactions on Environment and Electrical Engineering; 2015, 1, 1; 1-3
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-spark modeling of very fast transient overvoltages for the purposes of developing HV and UHV gas-insulated switchgear and of conducting insulation co-ordination studies
Autorzy:
Szewczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/200835.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
very fast transient overvoltages
VFTO
gas insulated switchgear
GIS
disconnector switch
DS
modeling
simulations
transients
switching
mitigation
breakdown voltage
BDV
odłącznik
modelowanie
symulacje
transjenty
przełączanie
łagodzenie
rozdzielnice izolowane gazem
Opis:
Very fast transient overvoltages (VFTO) originate from steep voltage breakdowns in SF6 gas that are inherent to operation of any switching device of the gas-insulated switchgear (GIS) type. For power stations with voltage ratings exceeding 500 kV, the ratio between equipment rated- and withstand-voltage levels becomes relatively low, which causes the VFTO peak values to reach the component’s insulation withstand-voltage levels, thus becoming a design factor for high- and ultra-high voltage GIS. While well-established approach to VFTO analyses involves only single VFTO events (the so-called single-spark approach), there is often the need to analyze the entire VFTO generation process, for which the multi-spark approach to VFTO modeling is to be employed. The multi-spark approach allows one to evaluate the VFTO impact on the GIS disconnector design along with the impact of the VFTO on selection and dimensioning of the VFTO damping solutions. As the multi-spark approach to VFTO modeling is now being increasingly used in UHV GIS developments as well as for the insulation co-ordination studies of power stations, the present paper is motivated by the need to report on the VFTO multi-spark modeling approach and to lay a common ground for development works that are supported extensively with VFTO simulations. The paper presents physical assumptions and modeling concepts that are in use in such modeling works. Development of the multi-spark GIS disconnector model for VFTO simulations is presented, followed by an overview of examples of the model application for the GIS development works and for insulation co-ordination studies.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 6; 871-882
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-39 z 39

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies