Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transducer" wg kryterium: Temat


Tytuł:
Cesarean scar pregnancy – a new challenge for obstetricians
Ciąża w bliźnie po cięciu cesarskim – nowe wyzwanie dla położników
Autorzy:
Pędraszewski, Piotr
Wlaźlak, Edyta
Panek, Wojciech
Surkont, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1033276.pdf
Data publikacji:
2018
Wydawca:
Medical Communications
Tematy:
transvaginal transducer
Opis:
Diagnosis and treatment of ectopic cesarean scar pregnancy has become a challenge for contemporary obstetrics. With an increase in the number of pregnancies concluded with a cesarean section and with the development of transvaginal ultrasonography, the frequency of cesarean scar pregnancy diagnoses has increased as well. The aim of the study is to evaluate various diagnostic methods (ultrasonography in particular) and analyze effective treatment methods for cesarean scar pregnancy. An ultrasound scan, Doppler examination and magnetic resonance imaging are all useful in early detection of asymptomatic cesarean scar pregnancy, thus enabling effective treatment and preservation of fertility. Dilatation and curettage is not recommended as it carries significant risk of bleeding and very high risk of hysterectomy and fertility loss. Systemic methotrexate treatment should not be applied on the routine basis due to its low efficacy, high risk of fertility loss and adverse effects. Local methotrexate therapy (under ultrasound or hysteroscopy guidance) should be considered a perfect management method as it offers fertility preservation in asymptomatic pregnant patients without concomitant hemodynamic disorders. Synchronous usage of several treatment methods is an effective way to manage cesarean scar pregnancy. The combination of local methotrexate with simultaneous aspiration of gestational tissues under ultrasound or hysteroscopy guidance seems optimal. Subsequently, the remaining gestational tissues can be removed hysteroscopically in combination with vascular coagulation at the implantation site. In more advanced cases, local methotrexate treatment should be considered followed by laparoscopic or laparotomic wedge resection with subsequent surgical correction of the cesarean section scar.
Rozpoznanie i leczenie ciąży ektopowej w bliźnie po cięciu cesarskim stało się dużym wyzwaniem dla współczesnego położnictwa. Wraz ze wzrostem liczby ciąż rozwiązywanych drogą cięcia cesarskiego oraz rozwojem przezpochwowych badań ultrasonograficznych częstość rozpoznawania ciąż w bliźnie po cięciu cesarskim uległa istotnemu zwiększeniu. Celem pracy jest ocena przydatności różnych metod diagnostycznych (w szczególności badania ultrasonograficznego) oraz analiza sposobów skutecznego leczenia ciąży ektopowej w bliźnie po cięciu cesarskim. Badanie ultrasonograficzne, dopplerowskie oraz rezonans magnetyczny są przydatne we wczesnym rozpoznawaniu bezobjawowej ciąży ektopowej w bliźnie po cięciu cesarskim, co pozwala na skuteczne leczenie oraz zachowanie płodności. Leczenie metodą rozszerzenia kanału szyjki i wyłyżeczkowania jamy macicy nie jest zalecane, ze względu na istotne zagrożenie krwotokiem oraz wysokie ryzyko histerektomii i utraty płodności. Systemowe podanie metotreksatu nie powinno być stosowane rutynowo, z uwagi na niską skuteczność, wysokie ryzyko utraty płodności oraz działania uboczne. Miejscową terapię metotreksatem (pod kontrolą ultrasonograficzną lub z wykorzystaniem histeroskopii) należy traktować jako doskonałą metodę postępowania, pozwalającą zachować płodność u ciężarnych asymptomatycznych, bez towarzyszących zaburzeń hemodynamicznych. Efektywnym sposobem terapii w przypadku ciąży w bliźnie po cięciu cesarskim jest równoległe zastosowanie kilku technik leczenia. Optymalne jest połączenie miejscowego zastosowania metotreksatu z jednoczesnym odessaniem zawartości jaja płodowego z wykorzystaniem ultrasonografii lub histeroskopii. Następnie można histeroskopowo usunąć pozostałe tkanki jaja płodowego w połączeniu z koagulacją naczyń krwionośnych w miejscu implantacji ciąży. W przypadkach bardziej zaawansowanych należy rozważyć lokalne podanie metotreksatu, a następnie drogą laparoskopii lub laparotomii – klinową resekcję zmiany z następczą korektą chirurgiczną blizny po cięciu cesarskim.
Źródło:
Journal of Ultrasonography; 2018, 18, 72; 56-62
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory investigations of dynamic properties of fractional-order accelerometers
Badania laboratoryjne właściwości dynamicznych akcelerometrów niecałkowitych rzędów
Autorzy:
Luft, M.
Szychta, E.
Pietruszczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/252402.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
akcelerometr
przetwornik pomiarowy
dynamika przetworników
accelerometer
measuring transducer
transducer dynamics
Opis:
The paper shows possibilities of using fractional calculus in dynamic measurements. It describes a laboratory measurement system for investigating dynamic properties of measuring transducers. Transducer’s dynamics are identified by the ARX method. Properties of the examined transducers of integral and fractional orders are compared. The authors indicate the fractional calculus advantages from the point of view of their dynamics description.
W artykule przedstawiono możliwości zastosowania rachunku różniczkowo-całkowego niecałkowitych rzędów w miernictwie dynamicznym. Przedstawiono układ pomiarowy do badań właściwości dynamicznych akcelerometrów W procesie identyfikacji przetwornika pomiarowego zastosowano metodę ARX. Porównano właściwości dynamiczne przetwornika pomiarowego całkowitego i niecałkowitego rzędu. Wskazano na zalety zastosowania rachunku różniczkowocałkowego niecałkowitych rzędów do opisu dynamiki przetworników pomiarowych.
Źródło:
TTS Technika Transportu Szynowego; 2013, 10; 423-436, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of self-oscillation in wire gauges
Autorzy:
Cieplok, G.
Kopij, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/279367.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
self-oscillation
wire transducer
Opis:
In the presented paper, an original solution to the system maintaining vibrations of a wire transducer, which has been based upon the phenomenon of self-oscillation, is described. The vibrations generated in this manner do not fade in time, are resistant to disturbances and allow measurement of the signal rapidly changing in time. The dynamic equations and numerical simulations of motion of the wire interconnected with the van der Pol oscillator are presented. Based on the conceptual model, a laboratory stand has been built, which served to verify properties of the presented solution and possibilities of useful applications.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 1; 29-39
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An experimental study on transducer for the DDS technology demonstrator
Autorzy:
Elminowicz, A.
Lis, W.
Męciński, W.
Powiązania:
https://bibliotekanauki.pl/articles/332550.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
transducer
DDS technology
sonar
Opis:
R&D MTC has began designing and building the next generation wideband Diver Detection Sonar (DDS, with cylindrical multielement piezocomposite transducer. The paper will focus on key features of DDS technology demonstrator, with special attention on technologies of the transducer. The new transducer is designed at the cooperation with the producer of the transducer - Materials Systems Inc. (Littleton, USA), remainder hardware and software solutions are designed in R&D MTC. In this article specific theoretical and technological principles of the wideband cylindrical piezocomposite transducer will be presented. The implementation of the transducer to the wideband Diver Detection Sonar (DDS) will be described. The results of transducer measurements, transmitter modules, matching circuits modeling and examples of application will be also presented.
Źródło:
Hydroacoustics; 2009, 12; 45-52
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetwornik pierwotny dla przepływomierza próbkującego
Primary transducer for the Sampling Flowmeter
Autorzy:
Zator, S.
Powiązania:
https://bibliotekanauki.pl/articles/157992.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
flow measurement
transducer
numerical calibration
Opis:
W artykule przedstawiono przetwornik hydrauliczny ze zmodyfikowaną dyszą ISA1932, którym możliwy jest pomiar strumienia objętości wody na podstawie punktowego pomiaru prędkości. Na podstawie obliczeń numerycznych przetwornika stwierdzono możliwość wykonywania pomiaru strumienia z niepewnością nie większą niż 3,5% wartości mierzonej dla zakresowości Qmax/Qmin = 100. Jednocześnie uzyskano niepewność pomiaru na poziomie 2,5% dla tej samej zakresowości po kalibracji przetwornika na stanowisku kontrolnym.
In this paper the hydraulic transducer with the modified nozzle ISA 1932 was presented. It was showed that it is possible to measure volume flow of water thanks to point measurement of speed with 3,5% uncertainty of measured value without making the calibration of the hydraulic transducer for range Qmax /Qmin = 100. For this transducer the 2,5% uncertainty of flow measurement was obtained for the same range after calibration on test stand. The results of investigations show the interesting propriety of existence of area, in which the relative profiles agree almost. Basis on the numeric calculations the appointed relative profiles of velocity permitted to calculate the relationship between average velocity in channel of transducer and the measured velocity in the select point. This came as result of investigations over construction of laser Doppler flowmeter, but they can be used in measurements of volume liquids flow in closed conduct using another methods of velocity measurement also.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 33-34
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tree transformations defined by hypersubstitutions
Autorzy:
Arworn, Sr.
Denecke, Klaus
Powiązania:
https://bibliotekanauki.pl/articles/728728.pdf
Data publikacji:
2001
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
hypersubstitution
tree transformation
tree transducer
Opis:
Tree transducers are systems which transform trees into trees just as automata transform strings into strings. They produce transformations, i.e. sets consisting of pairs of trees where the first components are trees belonging to a first language and the second components belong to a second language. In this paper we consider hypersubstitutions, i.e. mappings which map operation symbols of the first language into terms of the second one and tree transformations defined by such hypersubstitutions. We prove that the set of all tree transformations which are defined by hypersubstitutions of a given type forms a monoid with respect to the composition of binary relations which is isomorphic to the monoid of all hypersubstitutions of this type. We characterize transitivity, reflexivity and symmetry of tree transformations by properties of the corresponding hypersubstitutions. The results will be applied to languages built up by individual variables and one operation symbol of arity n ≥ 2.
Źródło:
Discussiones Mathematicae - General Algebra and Applications; 2001, 21, 2; 219-227
1509-9415
Pojawia się w:
Discussiones Mathematicae - General Algebra and Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pozycjonowanie serwonapędu elektropneumatycznego z bezpośrednim pomiarem przemieszczenia i prędkości tłoka siłownika
Positioning of electro-pneumatic servo-drive with direct displacement and velocity transducer
Autorzy:
Takosoglu, J.
Dindorf, R.
Łaski, P.
Woś, P.
Powiązania:
https://bibliotekanauki.pl/articles/386348.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
serwonapęd
regulator
servo-drive
transducer
Opis:
W artykule przedstawiono stanowisko eksperymentalne pozycjonowania serwonapędu elektropneumatycznego z bezpośrednim pomiarem przemieszczenia i prędkości tłoka siłownika za pomocą regulatora rozmytego. Analizowano wpływ zastosowanego przetwornika przemieszczenia i prędkości tłoka siłownika na dokładność regulacji serwonapędu elektropneumatycznego.
In the paper a research stand to positioning of electro-pneumatic servo-drive with direct displacement and velocity transducer are presented. The fuzzy logic controller constitute the control system. The performance control of the pneumatic servo-drive with new transducer was checked by means of standard performance index.
Źródło:
Acta Mechanica et Automatica; 2010, 4, 1; 86-91
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inductive current transducers in the frequency range up to 150 kHz
Autorzy:
Kosobudzki, G.
Dusza, D.
Powiązania:
https://bibliotekanauki.pl/articles/1193468.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current
Rogowski coil
inductive current transducer
Opis:
The article presents the results of the research on inductive current transducers in the form of a uniform winding non-magnetic ring with a rigid and flexible construction encompassing the flow of processed current in the frequency range of up to 150 kHz. The results for the developed transducer were related to the results obtained in simulations conducted on the transducer simplified model. The frequency tests of this type of transducers are of key significance in the assessment of the applicability of a given transducer in the measurements of network signals with high-order harmonics, and particularly in the assessment of the construction capacity of inductive current transducers in the form of the Rogowski coil.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 167-176
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy harvesting in a magnetopiezoelastic system driven by random excitations with uniform and Gaussian distributions
Pozyskiwanie energii w piezo-magnetycznym układzie sprężystym, pobudzanym siłą stochastyczną o rozkładzie jednorodnym i normalnym
Autorzy:
Litak, G.
Borowiec, M.
Friswell, M. I.
Adhikari, S.
Powiązania:
https://bibliotekanauki.pl/articles/279267.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
energy harvesting
piezoelectric transducer
random excitation
Opis:
A simple magneto-piezoelectric system excited by random forces modelled with a double well potential is considered. System responses for different realizations of noise with uniform and Gaussian distributions are compared. The results show negligible differences in the regions of small and high noise intensity. A more noticeable difference can be seen in the intermediate region of noise just below the transition from isolated single well oscillations to coupled double wells oscillations. Variations in the mechanical displacement in this transition region indicate that the transition between these types of behaviour is broader for a uniform noise excitation. Consequently, the system excited with Gaussian noise tends more clearly to one of the different solutions (i.e. motion in a single well or in both wells) while the uniform noise case demonstrates intermittency with multiple solutions.
W pracy analizowany jest prosty układ piezo-magnetyczny, pobudzany losowo z potencjałem o dwóch studniach. Porównywane są odpowiedzi układu przy różnej realizacji szumu, o rozkładzie jednorodnym i normalnym (Gaussowskim). Wyniki przedstawiają nieznaczne różnice w obszarach niskiej i wysokiej intensywności szumu. Bardziej zauważalną różnicę można dostrzec w obszarze pośrednim szumu, tuż poniżej przejścia z oscylacji w pojedynczej studni potencjału do oscylacji w dwóch sprzężonych studniach. Zmiany pracy układu w tym obszarze sygnalizują, że obszar przejść pomiędzy takimi typami rozwiązań jest szerszy przy pobudzaniu szumem o rozkładzie jednorodnym. Natomiast układ pobudzany szumem o rozkładzie normalnym wyraźniej wykazuje tendencje do pracy w zakresie jednego z typów rozwiązań. W rezultacie przy szumie Gaussowskim układ dąży do ruchu w obrębie tylko jednej lub dwóch studni potencjału, podczas gdy w obecności szumu jednorodnego, w zachowaniu układu pojawia się zjawisko intermitencji w realizacji dwóch rozwiązań.
Źródło:
Journal of Theoretical and Applied Mechanics; 2011, 49, 3; 757-764
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A high pressure resonator transducer with programmed correction of static characteristics
Autorzy:
Tomczuk, K.
Powiązania:
https://bibliotekanauki.pl/articles/220854.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pressure transducer
quartz resonator
algorithmic correction
Opis:
A high pressure resonator transducer (0 to 100 MPa) devised by the author has been described. The elastic element of the converter consists of a cylinder with an offset arranged axis hole. Quartz resonators were used for the measurement of deformations of the pipe. Based upon the results of the transducer testing, a new algorithmic method for the minimizalizsation of the temperature error, that eliminates the need for a temperature gauge has been worked out.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 667-677
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural modelling of throttle diagrams for measuring fluid parameters
Autorzy:
Pistun, Y.
Matiko, H.
Krykh, H.
Matiko, F.
Powiązania:
https://bibliotekanauki.pl/articles/221041.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
throttle diagram
measuring transducer
model
fluid
Opis:
In the paper there are presented tools for structural modelling of throttle diagrams that are developed as a basis to building transducers used for measuring fluid parameters. The definitions of throttle diagrams are improved and their classification is developed. Dependences are obtained to calculate the number of measuring channels in a throttle diagram and the number of possible variants of measuring transducers using the combinatory apparatus. A procedure for mathematical description of throttle diagrams in the form of graphs is proposed which makes it possible to obtain all diagrams with different measuring channels on the basis of certain throttle diagram. The model is developed in the form of a graph. A schematic diagram and a mathematical model of a transducer measuring physical and mechanical parameters of Bingham plastic fluid are developed based on a throttle diagram.
Źródło:
Metrology and Measurement Systems; 2018, 25, 4; 659-673
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowy przetwornik drgań - metoda badań, właściwości metrologiczne
New vibration transducer - methodology of testing, metrological characteristics
Autorzy:
Bartmański, C.
Mrukwa, W.
Powiązania:
https://bibliotekanauki.pl/articles/340282.pdf
Data publikacji:
2003
Wydawca:
Główny Instytut Górnictwa
Tematy:
przetwornik drgań
przetwornik A3R
charakterystyka częstotliwościowa
vibration transducer
A3R transducer
frequency characteristics
Opis:
Częstym skutkiem oddziaływania drgań mechanicznych na ludzi, uczestniczących w realizacji wielu procesów technologicznych, jest choroba zawodowa zwana zespołem wibracyjnym. Dotyczy to przede wszystkim przypadków, w których drgania przenoszone są do kończyn górnych pracowników obsługujących narzędzia ręczne o napędzie pneumatycznym i spalinowym. Zagrożenia człowieka w środowisku pracy, potwierdzone corocznymi raportami na temat zapadalności na choroby zawodowe wymagają systematycznych badań obejmujących pomiary parametrów drgań i, na ich podstawie, oszacowania stanu oddziaływania drgań na konkretnego pracownika Międzynarodowe i krajowe dokumenty normalizacyjne precyzują, miedzy innymi prawidłową, z uwagi na transmisję drgań do organizmu człowieka, lokalizację przetwornika dla tych pomiarów -w miejscu kontaktu rąk pracownika z drgającą powierzchnią. Brak odpowiednich przetworników pomiarowych uniemożliwia jednak taki pomiar i sprawia, że w praktyce powszechnie stosuje się metodę zastępczą, tj. pomiar obok rąk pracownika, sankcjonowaną co prawda przez przepisy metodyczne, będącą jednak odstępstwem, fałszującym w-pewnym stopniu wyniki pomiarów. W artykule przedstawiono wyniki kolejnego etapu badań, prowadzonych w celu opracowania metody pomiaru drgań w miejscu kontaktu rąk człowieka, odpowiadającej wymaganiom zawartym w krajowych i międzynarodowych dokumentach normalizacyjnych. Przedmiotem tego etapu badań był prototyp trójosiowego piezoelektrycznego przetwornika drgań, oznaczonego roboczym symbolem A3R firmy EMSON-MAT, skonstruowany specjalnie dla tego typu pomiarów. Z uwagi na specyficzny kształt przetwornika, zakres badań obejmował, opracowanie sposobu mocowania przetwornika do wzorcowego źródła drgań oraz pomiar parametrów metrologicznych przetwornika i określenie ich zgodności z wymaganiami zawartymi w przepisach metrologicznych. W ramach pomiarów parametrów metrologicznych wyznaczono czułości znamionowe, zmierzono charakterystyki przetwarzania i charakterystyki częstotliwościowe oraz wyznaczono, w ograniczonym zakresie, względne czułości poprzeczne przetwornika. Wyniki pomiarów zaprezentowano w formie tabel i wykresów. W wyniku badań stwierdzono, że prototypowy przetwornik drgań A3R spełnia wymagania metrologiczne ustalone w przepisach metrologicznych o piezoelektrycznych użytkowych przetwornikach drgań. Pozytywne wyniki pozwalają na kontynuację badań porównawczych dwóch sposobów lokalizacji miejsca pomiaru drgań - dotychczas stosowanego w praktyce, obok rak pracownika oraz nowego, w miejscu kontaktu rąk pracownika z drgającą powierzchnią, w warunkach symulujących pomiary na stanowisku pracy, na którym drgania są przenoszone do organizmu człowieka przez kończyny górne.
A frequent consequence of the influence of mechanical vibration on humans involved m technological processes is the occupational disease called the vibration syndrome. This refers, first of all, to the cases, in which vibration is transmitted to the upper limbs of the workers who operate hand-held equipment with pneumatic or combustion drive. the hazards in the work environment, confirmed by annual reports on the sick rates of the occupational diseases, need systematic investigations which include the measurements of vibration parameters, and, on that basis, the evaluation of the condition on vibration influence on an individual worker. The International and national standardisation documents precise, among the other things, a correct, in respect of vibration transmission to the human organism, location of the transducers for such measurements. TMs is the point of contact of the worker's hands with the vibrating surface. However, the lack of suitable measuring transducers makes such a measurement impossible, and causes that, in practice, a substitute method is commonly used that is the measurement beside the worker's hands. As a matter of fact, this is sanctioned by methodological regulations, but still it is a deviation, which falsify, to some extent, the results of measurements. The paper present the results of a consecutive phase of research conducted with the aim to develop a method for measuring vibration in the place of contact of the human hands, and fulfilling the requirements included in both domestic and international standardisation documents. The subject of this research phase was a prototype of the three-axial piezoelectric vibration transducer, manufactured by EMSON- MAT under the symbol A3R, and constructed especially for such type of measurements. Considering a specific shape of the transducer, the scope of research included the development of a method of fastening the transducer to Ihe reference source of vibration, and measurements of its metrological parameters, as well as defining their compatibility with the requirements contained in the metrological regulations. Within the framework of measurements of metrological parameters, the rated sensitivities, processing characteristics have been measured, and, to a limited extent, the relative transverse sensitivities of the transducer have been determined. The results of measurements were presented in the form of tables and diagrams. As a result of the conducted investigations, it was found that the prototype vibration transducer A3R meets the metrological requirements specified in the metrological regulations on usable piezoelectric vibration transducers. The positive results make possible to continue the comparative studies of two methods of location of vibration measurement, the one beside the hands, and used until now in practice, and the other, new one, being the place of contact of worker hands with the vibrating surface, in the conditions which simulate measurements at the work station where vibration is transmitted to the human organism through the upper limbs.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2003, 4; 69-80
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niepewność pomiaru długości z użyciem przetwornika pneumatycznego
Measurement uncertainty of air guages for length measurement
Autorzy:
Jakubowicz, M.
Jermak, C. J.
Powiązania:
https://bibliotekanauki.pl/articles/269592.pdf
Data publikacji:
2013
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
przetwornik pneumatyczny
przetwornik długości
pomiar bezdotykowy
niepewność pomiarów
pneumatic transducer
length transducer
non-contact measurement
measurement uncertainty
Opis:
W artykule omówiono wybrane aspekty analizy niepewności pomiaru długości z użyciem przetwornika pneumatycznego. W celu wyznaczenia niepewności pomiaru szerokości szczeliny s, przy wykorzystaniu systemu pomiarowego wyposażonego w pneumatyczny przetwornik długości oraz przetwornik ciśnienia, zastosowano procedurę wzorcowania i estymacji współczynników charakterystyki statycznej. Badania przeprowadzono dla przetworników z różnymi zestawami dysz. Przyjęte zestawy umożliwiły uzyskanie parametrów metrologicznych stosowanych w przemysłowych przyrządach pomiarowych. Uzyskane wyniki poddano analizie statystycznej i w jej efekcie ustalono, w jakim zakresie znajduje się poprawna wartość mierzonej szerokości szczeliny pomiarowej s.
This paper discusses some aspects of measurement uncertainty analysis in air gauges for measurement of length. Investigations was conducted on selected transducers with different sets of nozzles. Adopted combinations of nozzles enabled estimation of metrological parameters used in measuring instruments in conditions corresponding to those applied in industrial applications. The slot size was determined by the measurement system equipped with the air gauge equipped with pressure transducer. In order to evaluate the measurement uncertainty calibration procedure using the estimation of coefficients for static characteristics were applied. The results were statistically analyzed and the range in which there is a correct value of the measured slotsize s was determined.
Źródło:
Inżynieria Maszyn; 2013, R. 18, z. 3; 48-59
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interdigital transducers for lamb-wave based SHM systems: design and sensitivity analysis
Przetworniki IDT dla systemów monitorowania stanu konstrukcji z zastosowaniem fal lamba: projektowanie i analiza wrażliwości
Autorzy:
Mańka, M.
Rosiek, M.
Martowicz, A.
Uhl, T.
Powiązania:
https://bibliotekanauki.pl/articles/368907.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
fale Lamba
systemy monitorowania stanu konstrukcji
przetworniki międzypalczaste
IDT
Lamb waves
System Health Monitoring
transducer
interdigital transducer
Opis:
Structural health monitoring (SHM) systems have been constantly improved in the past decades. Sensors for SHM should be built-in to perform continuous measurements in opposite to non-destructive testing (NDT), in case of which sensors have to be mounted on the structure only during measurements. One of the most promising type of the transducers dedicated for SHM systems is Interdigital Transducer (IDT), which is designed for ultrasonic Lamb wave monitoring. Mode selectivity, high excitation strength, wave directivity, small size and relatively low cost are the most important advantages of the IDT. In the paper a designing process of the IDT is presented. Then, the results of numerical simulations and sensitivity analysis are discussed for exemplary IDT configuration.
Systemy monitorowania stanu konstrukcji (SHM) w ostatnich latach są dynamicznie rozwijane. Przetworniki wykorzystywane w tego typu systemach są na stałe montowane na badanej konstrukcji pozwalając na ciągły pomiar zmian jest stanu. Jednym z przetworników stosowanych w systemach SHM bazujących na powierzchniowych falach ultradźwiękowych są przetworniki międzypalczaste (IDT). Ich głównymi zaletami są małe rozmiary oraz zdolność do generowania wąskopasmowej fali kierunkowej o stosunkowo wysokiej amplitudzie. W artykule przedstawiony został proces projektowania przetworników IDT. Omówiono wyniki przeprowadzonych symulacji oraz procesu analizy wrażliwości dla przedstawionej konstrukcji.
Źródło:
Mechanics and Control; 2011, 30, 2; 79-84
2083-6759
2300-7079
Pojawia się w:
Mechanics and Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype of Wideband Air Sonar Based on STM32
Autorzy:
Okoń-Fąfara, M.
Kawalec, A.
Fąfara, B.
Powiązania:
https://bibliotekanauki.pl/articles/176827.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
imaging air sonar
STM32
ultrasonic transducer
Opis:
The paper presents a project of a low-cost prototype version of a wideband air sonar and the problems occurring during its development process. The aim of this work was to design a short range air sonar capable of creating the reflectivity map of its surroundings using an arbitrary shape wideband signal. The transmitting and receiving transducers that have been chosen for this application typically work in pulsed operation modes. Therefore, dedicated output and input circuits had to be designed to expand its capabilities without information losses. The signal generation, transmission, reception and storage are managed by a Discovery evaluation board with a STM32 microcontroller. The receiving data are saved on a SD card and are processed off-line.
Źródło:
Archives of Acoustics; 2017, 42, 4; 761-765
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound
Autorzy:
Secomski, W.
Nowicki, A.
Wójcik, J.
Lewandowski, M.
Walczak, M.
Tymkiewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/177840.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic therapy
annular array transducer
ultrasonic field
Opis:
The use of therapeutic ultrasound continues to grow. A focused ultrasonic wave can increase the tissue temperature locally for the non-invasive cancer treatment or other medical applications. The authors have designed a seven-element annular array transducer operating at 2.4 MHz. Each element was excited by sine burst supplied by a linear amplifier and FPGA control circuits. The acoustic field, generated by a transducer was initially numerically simulated in a computer and next compared to water tank hydrophone measurements performed at 20, 40 and 60 mm focal depth. The results showed good agreement of the measurements with theory and the possibility to focus the ultrasound in the preselected area. The total acoustic power radiated by the annular array was equal to 2.4 W.
Źródło:
Archives of Acoustics; 2010, 35, 4; 653-660
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data processing of broad-band signals received by multi-element cylindrical transducer
Autorzy:
Janowski, T.
Elminowicz, A.
Szworski, K.
Powiązania:
https://bibliotekanauki.pl/articles/331559.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
data processing
multi-element cylindrical transducer
hydroacoustic
Opis:
The sonar based on cylindrical transducer compared with linear transducer has few advantages. Particularly its omni-directional central symmetry enables simplification of the echo signal Direction of Arrival (DOA) estimation. When the number of transducer staves is the power of two the efficient Fast Fourier Transformation can be used to calculate spatial convolution. The article presents theoretical and technological principles of the real time digital data processing of the wideband echo signals received by cylindrical hydroacoustic transducer. Described procedures enable high resolution underwater target location and precise data display. The implementation of effective broadband pulse compression technique with high range resolution will be presented. The results of signal processing modeling and examples of application will be also discussed.
Źródło:
Hydroacoustics; 2008, 11; 113-120
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the transducer bandwidth and double pulse transmission on the encoded imaging ultrasound
Autorzy:
Trots, I.
Nowicki, A.
Lewandowski, M.
Secomski, W.
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/331651.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
encoded imaging ultrasound
ultrasound imaging transducer
CGS
Opis:
An influence effect of fractional bandwidth of ultrasound imaging transducer on the gain of compressed echo signal being the complementary Golay sequences (CGS) with different spectral widths is studied in this paper. Also, a new composing transmission method of CGS is discussed together with compression technique applied in order to increase the signal-to-noise ratio (SNR) and penetration. The CGS with two different bit lengths, one-cycle and two-cycles are investigated. Two transducers with fractional bandwidth of 25% and 80% at centre frequency 6 MHz are used. The experimental results are presented, clearly proofing that increasing of the code length leads to compressed echo amplitude enhancement. The smaller the bandwidth is the larger is this effect; the pulse-echo sensitivity of the echo amplitude increases by 1.88 for 25% fractional bandwidth and 1.47 for 80% while preserving time resolution. The presented results of double transmission of short codes show the penetration and SNR improvement while maintaining dead zone.
Źródło:
Hydroacoustics; 2008, 11; 419-430
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and optimization of a cross-beam force transducer for a stationary dynamometer for measuring milling cutting force
Autorzy:
Rizal, Muhammad
Ghani, Jaharah A.
Usman, Husni
Dirhamsyah, Muhammad
Mubarak, Amir Zaki
Powiązania:
https://bibliotekanauki.pl/articles/24084662.pdf
Data publikacji:
2023
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
force transducer optimisation
stationary dynamometer
cutting force measurement
Opis:
This paper’s objective is to design and optimize a force transducer to build a stationary dynamometer that can measure three axes of milling cutting force. To reduce interference error and increase sensitivity, the force transducer's Maltese cross-beam design was optimized. The force transducer's performance depends on three design parameters: the cross-rectangular beam's through-hole length and width, the compliant plate thickness, and the strain, stress, and stiffness of force transducer constructions calculated by ANSYS. The response surface method (RSM) estimates a desired second-order polynomial function for three geometric parameters based on sensitivity, interference error, safety factor, and stiffness. A stationary dynamometer prototype was made with four optimized force transducers and several piezoresistive strain sensors. The developed dynamometer has good linearity, repeatability, and hysteresis, as well as high sensitivities and low cross-sensitivity errors. The reference dynamometer's cutting force measurements were very close to those of the designed dynamometer in the validation test.
Źródło:
Journal of Machine Engineering; 2023, 23, 2; 41--65
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Binary valves in analog control
Autorzy:
Mielewczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/242392.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
control
digital signal
actuator
control valve
transducer
positioner
Opis:
Continuous control systems are built with standard transducer measured signal, the controller and actuator. The actuator is responsible for the direct setting of the size of the control object. The actuator is connected to the control valve and the actuator position change signal into the flow rate of the working medium. Since the operating element is required the linear characteristics in the standard signal range to work. The other hand, the control valve provides flow characteristics linear or equal percentage. This flow control principle is used in various control systems. The actuator of the control valve is always equipped with a positioner, which corrects errors in the position of the valve relative to the input signal. The presented design of the control valve is an analogue system. Using the technique of converting multiple digital signal causes, the system is susceptible to damage. Remove the intermediate elements can improve the quality control and safety system. Such benefits give a design of the operating element based on direct digital processing unit and control program. The examples of control present article.
Źródło:
Journal of KONES; 2017, 24, 2; 141-146
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comparison of the metrological properties of two-core current transformers
Porównanie właściwości metrologicznych dwurdzeniowych przekładników prądowych
Autorzy:
Dusza, D.
Powiązania:
https://bibliotekanauki.pl/articles/156954.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
current
processing
current transducer
prąd
przetwarzanie
przekładnik prądowy
Opis:
The paper presents a comparative analysis of the two-core Brooks and Brooks &Holtz transformers used in precision measuring systems. The derived relations indicate that the two-core Brooks & Holtz transformer has much better metrological properties. The metrological analysis was verified by the results of tests carried out on standard transformers. The analysis and the results can be used in the design of two-core transformers.
W artykule przedstawiono porównanie właściwości metrologicznych przekładników prądowych Brooksa oraz Brooksa i Holtza [3]. W rozdziale 2.1 przedstawiono przekładnik jednordzeniowy, którego błąd opisano za pomocą impedancji jego obwodu zastępczego (rys. 1b). W rozdziale 2.2 pokazano schemat zastępczy przekładnika Brooksa i na tej podstawie wyprowadzono wzór (2) określający błąd przekładnika. Przy założeniu (3) uproszczono wzór (2) do postaci (5), z którego wynika, że błąd przekładnika zależy głównie od impedancji obciążenia. Pokazano również wpływ błędu przekładnika pomocniczego ACIT (6) na błąd przetwarzania przekładnika Brooksa. Ze wzoru (10) wynika, że magnetowód przekładnika pomocniczego powinien być wykonany z materiału ferromagnetycznego o dużej wartości przenikalności początkowej, tj. permaloj, taśma amorficzna. W rozdziale 2.3 pokazano strukturę i analizę przekładnika Brooksa i Holtza. Z analizy wynika, że przekładnik ten powinien charakteryzować się lepszymi parametrami metrologicznymi, niż przekładnik Brooksa i Holtza, ponieważ w równaniu występuje iloczyn błędów przekładnika głównego i pomocniczego. W rozdziale 3 pokazano zastosowane układy pomiarowe do wyznaczania błędów przekładnika Brooksa (rys. 4) oraz Brooksa i Holtza (rys.5), które realizują metodę kompensacyjno-różnicową. W rozdziale 4 przedstawiono wyniki badań dla błędów prądowych i kątowych. Z otrzymanych wyników badań określono klasę przekładnika Brooksa jako 0,5 oraz dla połączenia Brooksa i Holtza 0,05.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 568-572
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern actuator
Autorzy:
Mielewczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/242423.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
main engine
control
controller
actuator
regulating valve
transducer
Opis:
The main engine of the ship is a complex technical object, which provides propulsion of the screw and ensures the safety of a ship at sea. It consists of a number of control systems such as lube oil temperature control, temperature control of the cooling water, fuel viscosity control or adjustable speed control of the main engine. Each of the main propulsion control system affects the safety of the ship. Continuous automation systems are built with standard transducer of measured quantity, the controller and actuator. The actuator is responsible for the direct setting of the size of the control object. The actuator is connected to the control valve and the actuator position change translates into a change in the flow rate of the working medium. Thus, the operating element is required to operate in the linear characteristics of the standard signal range. From the other hand, the control valve provides flow characteristics linear or of equal percentage. This control principle of medium flow is used in various control systems. The actuator of the control valve is always equipped with a positioner, which corrects errors in the position of the valve relative to the input signal. The presented design of the motorized valve is an analog system. Using the technique of converting multiple digital signal causes the system complexity and predisposition to damage. Eliminating the intermediate elements can improve the quality control and system safety. Then it is beneficial to have a design of the operating element based on the direct digital processing unit. The aim of paper has been to present design of the valve actuator, which completely abandons the digital-to-analogue convertor. The new design should increase the level of security of the system and quality control. The design layout is presented in the article. The new actuator is on-off valves, which control, directly from the digital bits, the form of the output signal. The control signal may use the control algorithms to be used or developed individually to the actuator design.
Źródło:
Journal of KONES; 2014, 21, 2; 221-226
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Description of selected pneumatic elements and systems using fractional calculus
Wybrane elementy i układy pneumatyczne opisane za pomocą rachunku różniczkowego niecałkowitych rzędów
Autorzy:
Pietruszczak, Daniel
Nowocień, Artur
Powiązania:
https://bibliotekanauki.pl/articles/106071.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
fractional calculus
pressure transducer
rachunek różniczkowy niecałkowitych rzędów
Opis:
The paper presents the application of fractional calculus to describe the dynamics of selected pneumatic elements and systems. In the construction of mathematical models of the analysed dynamic systems, the Riemann-Liouville definition of differintegral of non- integer order was used. For the analysed model, transfer function of integer and non-integer order was determined. Functions describing characteristics in frequency domains were determined, whereas the characteristics of the elements and systems were obtained by means of computer simulation. MATLAB programme were used for the simulation research.
W artykule przedstawiono zastosowanie rachunku różniczkowego niecałkowitych rzędów (ang. fractional calculus) do opisu dynamiki zjawisk układów pneumatycznych wybranych elementów i układów. W budowie modeli matematycznych, analizowanych układów dynamicznych, wykorzystano definicję Riemanna–Liouville’a pochodno–całki niecałkowitego rzędu. Dla analizowanego modelu, wyznaczono transmitancję operatorową całkowitego i niecałkowitego rzędu. Wyznaczono zależności opisujące charakterystyki częstotliwościowe, na drodze symulacji komputerowej uzyskano charakterystyki analizowanych układów. Do badań symulacyjnych wykorzystano oprogramowanie MATLAB.
Źródło:
Journal of Automation, Electronics and Electrical Engineering; 2019, 1, 1; 43-49
2658-2058
2719-2954
Pojawia się w:
Journal of Automation, Electronics and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Sensitivity Field of Dual Transducer Probes on Accuracy of Discontinuity Sizing and Evaluation in Terms of Testing of Forgings According to EN 10228-3
Autorzy:
Kaczmarek, R.
Kaczmarek, K.
Powiązania:
https://bibliotekanauki.pl/articles/352659.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
non destructive testing
ultrasonic testing
double transducer probe
Opis:
The article presents results of research on the impact of sensitivity distribution of double transducer probes, which are often used in non-destructive ultrasonic testing of components such as forgings. Distribution of sensitivity measured in two orientations, parallel and perpendicular to the plane of separation of a double transducer probe has been tested and analyzed. A significant influence of orientation of a probe on echo envelope of an artificial point discontinuity has been studied. It has revealed great differences in length and shape of an echo envelope, depending on a type of probe and orientation of a probe separation plane to the moving direction. Eventually, the analysis of practical consequences of dual transducer probes usage for characterization of a type, dimensioning and evaluation of internal discontinuities, in accordance to the methodology specified in EN 10228, has been conducted.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1677-1682
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt siłomierza z zastosowaniem tensometrii oporowej
The force transducer design with strain gauges method application
Autorzy:
Molski, T.
Baier, A.
Powiązania:
https://bibliotekanauki.pl/articles/408983.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska
Tematy:
tensometria oporowa
siłomierz
metoda elementów skończonych
program Unigraphics NX
strain gauge transducer
force transducer
finite elements method
Unigraphics NX program
Opis:
W artykule przedstawiono model stanowiska z siłomierzem. Pokazano ogólną konstrukcję siłomierza, metodę archiwizacji danych oraz przeprowadzono pomiary z zastosowaniem tensometrii elektrooporowej. Kolejno wykonano niezbędne obliczenia i sprawdzono ich poprawność, wykorzystując analizę MES w programie Unigraphics NX7.
The article describes approach to design of force transducer. Its general form, the method of data archiving were introduced. Moreover, measurements with strain gauges method were introduced. The necessary calculations were performed and verified by FEM analysis in Unigraphics NX7 program.
Źródło:
Wybrane Problemy Inżynierskie; 2010, 1; 73-77
2083-1021
Pojawia się w:
Wybrane Problemy Inżynierskie
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies