Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transducer" wg kryterium: Temat


Tytuł:
Cesarean scar pregnancy – a new challenge for obstetricians
Ciąża w bliźnie po cięciu cesarskim – nowe wyzwanie dla położników
Autorzy:
Pędraszewski, Piotr
Wlaźlak, Edyta
Panek, Wojciech
Surkont, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1033276.pdf
Data publikacji:
2018
Wydawca:
Medical Communications
Tematy:
transvaginal transducer
Opis:
Diagnosis and treatment of ectopic cesarean scar pregnancy has become a challenge for contemporary obstetrics. With an increase in the number of pregnancies concluded with a cesarean section and with the development of transvaginal ultrasonography, the frequency of cesarean scar pregnancy diagnoses has increased as well. The aim of the study is to evaluate various diagnostic methods (ultrasonography in particular) and analyze effective treatment methods for cesarean scar pregnancy. An ultrasound scan, Doppler examination and magnetic resonance imaging are all useful in early detection of asymptomatic cesarean scar pregnancy, thus enabling effective treatment and preservation of fertility. Dilatation and curettage is not recommended as it carries significant risk of bleeding and very high risk of hysterectomy and fertility loss. Systemic methotrexate treatment should not be applied on the routine basis due to its low efficacy, high risk of fertility loss and adverse effects. Local methotrexate therapy (under ultrasound or hysteroscopy guidance) should be considered a perfect management method as it offers fertility preservation in asymptomatic pregnant patients without concomitant hemodynamic disorders. Synchronous usage of several treatment methods is an effective way to manage cesarean scar pregnancy. The combination of local methotrexate with simultaneous aspiration of gestational tissues under ultrasound or hysteroscopy guidance seems optimal. Subsequently, the remaining gestational tissues can be removed hysteroscopically in combination with vascular coagulation at the implantation site. In more advanced cases, local methotrexate treatment should be considered followed by laparoscopic or laparotomic wedge resection with subsequent surgical correction of the cesarean section scar.
Rozpoznanie i leczenie ciąży ektopowej w bliźnie po cięciu cesarskim stało się dużym wyzwaniem dla współczesnego położnictwa. Wraz ze wzrostem liczby ciąż rozwiązywanych drogą cięcia cesarskiego oraz rozwojem przezpochwowych badań ultrasonograficznych częstość rozpoznawania ciąż w bliźnie po cięciu cesarskim uległa istotnemu zwiększeniu. Celem pracy jest ocena przydatności różnych metod diagnostycznych (w szczególności badania ultrasonograficznego) oraz analiza sposobów skutecznego leczenia ciąży ektopowej w bliźnie po cięciu cesarskim. Badanie ultrasonograficzne, dopplerowskie oraz rezonans magnetyczny są przydatne we wczesnym rozpoznawaniu bezobjawowej ciąży ektopowej w bliźnie po cięciu cesarskim, co pozwala na skuteczne leczenie oraz zachowanie płodności. Leczenie metodą rozszerzenia kanału szyjki i wyłyżeczkowania jamy macicy nie jest zalecane, ze względu na istotne zagrożenie krwotokiem oraz wysokie ryzyko histerektomii i utraty płodności. Systemowe podanie metotreksatu nie powinno być stosowane rutynowo, z uwagi na niską skuteczność, wysokie ryzyko utraty płodności oraz działania uboczne. Miejscową terapię metotreksatem (pod kontrolą ultrasonograficzną lub z wykorzystaniem histeroskopii) należy traktować jako doskonałą metodę postępowania, pozwalającą zachować płodność u ciężarnych asymptomatycznych, bez towarzyszących zaburzeń hemodynamicznych. Efektywnym sposobem terapii w przypadku ciąży w bliźnie po cięciu cesarskim jest równoległe zastosowanie kilku technik leczenia. Optymalne jest połączenie miejscowego zastosowania metotreksatu z jednoczesnym odessaniem zawartości jaja płodowego z wykorzystaniem ultrasonografii lub histeroskopii. Następnie można histeroskopowo usunąć pozostałe tkanki jaja płodowego w połączeniu z koagulacją naczyń krwionośnych w miejscu implantacji ciąży. W przypadkach bardziej zaawansowanych należy rozważyć lokalne podanie metotreksatu, a następnie drogą laparoskopii lub laparotomii – klinową resekcję zmiany z następczą korektą chirurgiczną blizny po cięciu cesarskim.
Źródło:
Journal of Ultrasonography; 2018, 18, 72; 56-62
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory investigations of dynamic properties of fractional-order accelerometers
Badania laboratoryjne właściwości dynamicznych akcelerometrów niecałkowitych rzędów
Autorzy:
Luft, M.
Szychta, E.
Pietruszczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/252402.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
akcelerometr
przetwornik pomiarowy
dynamika przetworników
accelerometer
measuring transducer
transducer dynamics
Opis:
The paper shows possibilities of using fractional calculus in dynamic measurements. It describes a laboratory measurement system for investigating dynamic properties of measuring transducers. Transducer’s dynamics are identified by the ARX method. Properties of the examined transducers of integral and fractional orders are compared. The authors indicate the fractional calculus advantages from the point of view of their dynamics description.
W artykule przedstawiono możliwości zastosowania rachunku różniczkowo-całkowego niecałkowitych rzędów w miernictwie dynamicznym. Przedstawiono układ pomiarowy do badań właściwości dynamicznych akcelerometrów W procesie identyfikacji przetwornika pomiarowego zastosowano metodę ARX. Porównano właściwości dynamiczne przetwornika pomiarowego całkowitego i niecałkowitego rzędu. Wskazano na zalety zastosowania rachunku różniczkowocałkowego niecałkowitych rzędów do opisu dynamiki przetworników pomiarowych.
Źródło:
TTS Technika Transportu Szynowego; 2013, 10; 423-436, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of self-oscillation in wire gauges
Autorzy:
Cieplok, G.
Kopij, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/279367.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
self-oscillation
wire transducer
Opis:
In the presented paper, an original solution to the system maintaining vibrations of a wire transducer, which has been based upon the phenomenon of self-oscillation, is described. The vibrations generated in this manner do not fade in time, are resistant to disturbances and allow measurement of the signal rapidly changing in time. The dynamic equations and numerical simulations of motion of the wire interconnected with the van der Pol oscillator are presented. Based on the conceptual model, a laboratory stand has been built, which served to verify properties of the presented solution and possibilities of useful applications.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 1; 29-39
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An experimental study on transducer for the DDS technology demonstrator
Autorzy:
Elminowicz, A.
Lis, W.
Męciński, W.
Powiązania:
https://bibliotekanauki.pl/articles/332550.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
transducer
DDS technology
sonar
Opis:
R&D MTC has began designing and building the next generation wideband Diver Detection Sonar (DDS, with cylindrical multielement piezocomposite transducer. The paper will focus on key features of DDS technology demonstrator, with special attention on technologies of the transducer. The new transducer is designed at the cooperation with the producer of the transducer - Materials Systems Inc. (Littleton, USA), remainder hardware and software solutions are designed in R&D MTC. In this article specific theoretical and technological principles of the wideband cylindrical piezocomposite transducer will be presented. The implementation of the transducer to the wideband Diver Detection Sonar (DDS) will be described. The results of transducer measurements, transmitter modules, matching circuits modeling and examples of application will be also presented.
Źródło:
Hydroacoustics; 2009, 12; 45-52
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetwornik pierwotny dla przepływomierza próbkującego
Primary transducer for the Sampling Flowmeter
Autorzy:
Zator, S.
Powiązania:
https://bibliotekanauki.pl/articles/157992.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
flow measurement
transducer
numerical calibration
Opis:
W artykule przedstawiono przetwornik hydrauliczny ze zmodyfikowaną dyszą ISA1932, którym możliwy jest pomiar strumienia objętości wody na podstawie punktowego pomiaru prędkości. Na podstawie obliczeń numerycznych przetwornika stwierdzono możliwość wykonywania pomiaru strumienia z niepewnością nie większą niż 3,5% wartości mierzonej dla zakresowości Qmax/Qmin = 100. Jednocześnie uzyskano niepewność pomiaru na poziomie 2,5% dla tej samej zakresowości po kalibracji przetwornika na stanowisku kontrolnym.
In this paper the hydraulic transducer with the modified nozzle ISA 1932 was presented. It was showed that it is possible to measure volume flow of water thanks to point measurement of speed with 3,5% uncertainty of measured value without making the calibration of the hydraulic transducer for range Qmax /Qmin = 100. For this transducer the 2,5% uncertainty of flow measurement was obtained for the same range after calibration on test stand. The results of investigations show the interesting propriety of existence of area, in which the relative profiles agree almost. Basis on the numeric calculations the appointed relative profiles of velocity permitted to calculate the relationship between average velocity in channel of transducer and the measured velocity in the select point. This came as result of investigations over construction of laser Doppler flowmeter, but they can be used in measurements of volume liquids flow in closed conduct using another methods of velocity measurement also.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 33-34
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tree transformations defined by hypersubstitutions
Autorzy:
Arworn, Sr.
Denecke, Klaus
Powiązania:
https://bibliotekanauki.pl/articles/728728.pdf
Data publikacji:
2001
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
hypersubstitution
tree transformation
tree transducer
Opis:
Tree transducers are systems which transform trees into trees just as automata transform strings into strings. They produce transformations, i.e. sets consisting of pairs of trees where the first components are trees belonging to a first language and the second components belong to a second language. In this paper we consider hypersubstitutions, i.e. mappings which map operation symbols of the first language into terms of the second one and tree transformations defined by such hypersubstitutions. We prove that the set of all tree transformations which are defined by hypersubstitutions of a given type forms a monoid with respect to the composition of binary relations which is isomorphic to the monoid of all hypersubstitutions of this type. We characterize transitivity, reflexivity and symmetry of tree transformations by properties of the corresponding hypersubstitutions. The results will be applied to languages built up by individual variables and one operation symbol of arity n ≥ 2.
Źródło:
Discussiones Mathematicae - General Algebra and Applications; 2001, 21, 2; 219-227
1509-9415
Pojawia się w:
Discussiones Mathematicae - General Algebra and Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pozycjonowanie serwonapędu elektropneumatycznego z bezpośrednim pomiarem przemieszczenia i prędkości tłoka siłownika
Positioning of electro-pneumatic servo-drive with direct displacement and velocity transducer
Autorzy:
Takosoglu, J.
Dindorf, R.
Łaski, P.
Woś, P.
Powiązania:
https://bibliotekanauki.pl/articles/386348.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
serwonapęd
regulator
servo-drive
transducer
Opis:
W artykule przedstawiono stanowisko eksperymentalne pozycjonowania serwonapędu elektropneumatycznego z bezpośrednim pomiarem przemieszczenia i prędkości tłoka siłownika za pomocą regulatora rozmytego. Analizowano wpływ zastosowanego przetwornika przemieszczenia i prędkości tłoka siłownika na dokładność regulacji serwonapędu elektropneumatycznego.
In the paper a research stand to positioning of electro-pneumatic servo-drive with direct displacement and velocity transducer are presented. The fuzzy logic controller constitute the control system. The performance control of the pneumatic servo-drive with new transducer was checked by means of standard performance index.
Źródło:
Acta Mechanica et Automatica; 2010, 4, 1; 86-91
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inductive current transducers in the frequency range up to 150 kHz
Autorzy:
Kosobudzki, G.
Dusza, D.
Powiązania:
https://bibliotekanauki.pl/articles/1193468.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current
Rogowski coil
inductive current transducer
Opis:
The article presents the results of the research on inductive current transducers in the form of a uniform winding non-magnetic ring with a rigid and flexible construction encompassing the flow of processed current in the frequency range of up to 150 kHz. The results for the developed transducer were related to the results obtained in simulations conducted on the transducer simplified model. The frequency tests of this type of transducers are of key significance in the assessment of the applicability of a given transducer in the measurements of network signals with high-order harmonics, and particularly in the assessment of the construction capacity of inductive current transducers in the form of the Rogowski coil.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 167-176
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy harvesting in a magnetopiezoelastic system driven by random excitations with uniform and Gaussian distributions
Pozyskiwanie energii w piezo-magnetycznym układzie sprężystym, pobudzanym siłą stochastyczną o rozkładzie jednorodnym i normalnym
Autorzy:
Litak, G.
Borowiec, M.
Friswell, M. I.
Adhikari, S.
Powiązania:
https://bibliotekanauki.pl/articles/279267.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
energy harvesting
piezoelectric transducer
random excitation
Opis:
A simple magneto-piezoelectric system excited by random forces modelled with a double well potential is considered. System responses for different realizations of noise with uniform and Gaussian distributions are compared. The results show negligible differences in the regions of small and high noise intensity. A more noticeable difference can be seen in the intermediate region of noise just below the transition from isolated single well oscillations to coupled double wells oscillations. Variations in the mechanical displacement in this transition region indicate that the transition between these types of behaviour is broader for a uniform noise excitation. Consequently, the system excited with Gaussian noise tends more clearly to one of the different solutions (i.e. motion in a single well or in both wells) while the uniform noise case demonstrates intermittency with multiple solutions.
W pracy analizowany jest prosty układ piezo-magnetyczny, pobudzany losowo z potencjałem o dwóch studniach. Porównywane są odpowiedzi układu przy różnej realizacji szumu, o rozkładzie jednorodnym i normalnym (Gaussowskim). Wyniki przedstawiają nieznaczne różnice w obszarach niskiej i wysokiej intensywności szumu. Bardziej zauważalną różnicę można dostrzec w obszarze pośrednim szumu, tuż poniżej przejścia z oscylacji w pojedynczej studni potencjału do oscylacji w dwóch sprzężonych studniach. Zmiany pracy układu w tym obszarze sygnalizują, że obszar przejść pomiędzy takimi typami rozwiązań jest szerszy przy pobudzaniu szumem o rozkładzie jednorodnym. Natomiast układ pobudzany szumem o rozkładzie normalnym wyraźniej wykazuje tendencje do pracy w zakresie jednego z typów rozwiązań. W rezultacie przy szumie Gaussowskim układ dąży do ruchu w obrębie tylko jednej lub dwóch studni potencjału, podczas gdy w obecności szumu jednorodnego, w zachowaniu układu pojawia się zjawisko intermitencji w realizacji dwóch rozwiązań.
Źródło:
Journal of Theoretical and Applied Mechanics; 2011, 49, 3; 757-764
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A high pressure resonator transducer with programmed correction of static characteristics
Autorzy:
Tomczuk, K.
Powiązania:
https://bibliotekanauki.pl/articles/220854.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pressure transducer
quartz resonator
algorithmic correction
Opis:
A high pressure resonator transducer (0 to 100 MPa) devised by the author has been described. The elastic element of the converter consists of a cylinder with an offset arranged axis hole. Quartz resonators were used for the measurement of deformations of the pipe. Based upon the results of the transducer testing, a new algorithmic method for the minimizalizsation of the temperature error, that eliminates the need for a temperature gauge has been worked out.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 667-677
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies