Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal power" wg kryterium: Temat


Tytuł:
The fresh waters of the Krakow region as the lower source for heat pumps
Autorzy:
Uliasz-Misiak, B.
Winid, B.
Chodań, E.
Powiązania:
https://bibliotekanauki.pl/articles/299054.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
groundwater
heat pump
temperature
thermal power
Krakow
Opis:
Krakow is a city facing a big problem with air pollution, the use of energy accumulated in groundwater may contribute to reducing emissions of gases and dust to the atmosphere. The article analyzes the possibilities of using groundwater made available with intakes located in Krakow. Estimated water temperatures were ranging from 7.9 to 9.7°C. The thermal power that can be obtained in groundwater varies for individual intakes and allows for obtaining thermal outputs from 0.395 to 1108.035 kW, according to calculations. The analysis of groundwater chemistry in the Krakow region and their comparison with the recommendations of heat pump manufacturers indicates that the use of water as a lower heat source may in some cases cause technical problems.
Źródło:
AGH Drilling, Oil, Gas; 2018, 35, 1; 187-200
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas Formation Reactions in the Raw Mixture Based on TPP Ash
Autorzy:
Koshlak, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/2069926.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
swelling
porous structure
ash of thermal power plants
Opis:
The article discusses the physicochemical mechanisms of the effect of chemical reagents on the processes of swelling of the raw mixture based on the ash of thermal power plants. The process of structure formation in such mixtures occurs as a result of physicochemical transformations of its constituent components. To intensify gas evolution and obtain materials of a porous structure, the presence of a gas former is necessary. The author has analysed the possibility of creating a porous structure in a raw mixture based on ash with the introduction of various gas formers or their formation as a result of exchange reactions. The main chemical compounds contributing to pore formation have been determined. To form a given structure, it is proposed to control chemical transformations at the stage of swelling. To study the processes of intensification of gas evolution, the author proposes to investigate the mechanisms of the influence of mineral fillers and chemical reagents on swelling processes based on the analysis of the Gibbs equation. The parameters of the Gibbs equation are obtained, by which it is possible to determine the probability of the occurrence of chemical reactions with the proposed chemical agents for the formation of gas bubbles with (pores) in the raw material.
Źródło:
Rocznik Ochrona Środowiska; 2021, 23; 106--116
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reactivity of marble wastes for potential utilization in wet flue gas desulphurization
Autorzy:
Altun, N. E.
Powiązania:
https://bibliotekanauki.pl/articles/110132.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
marble
reactivity
thermal power production
SO2
desulphurization
Opis:
Wastes of most marble types are distinguished with their superior CaCO3 content and potential to utilize them as an alternative to limestone. Control of SO2 using marble wastes in wet flue gas desulphurization (WFGD) units of coal fired thermal power plants is an important opportunity. In this study, nine types of marble wastes were evaluated in terms of their ability to dissolution (reactivity) in an acidic environment. The reactivity was expressed as fractional conversion with time with respect to the chemical composition and particle distribution of wastes as well as temperature and pH of solution. Dissolution reaction rate constants were also computed. Reactivity of the wastes varied significantly with chemical compositions of the marble types. The same marble type displayed different dissolution profiles as a function of test conditions (fineness, temperature, pH). Higher contents of CaCO3 and Fe2O3 positively influenced dissolution ability and rates, whereas increased MgCO3 content had adverse effects. The changes in particle size, temperature and pH influenced the reactivity. The reactivity increased with decreasing particle size. Also, higher temperature and increased acidity favored dissolution ability of the marble wastes. Our results showed that under optimized conditions marble wastes, having a higher content of CaCO3 and low content of MgCO3, are potential SO2 sorbent alternative.
Źródło:
Physicochemical Problems of Mineral Processing; 2016, 52, 1; 497-509
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The demand analysis of the biogas plant with chp system on substrate, the aim to obtain required electrical and thermal power
Autorzy:
Piętak, A.
Meus, M.
Nitkiewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/246798.pdf
Data publikacji:
2012
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
biogas
biogas plant
cogeneration
electrical power
renewable energy
thermal power
transportation
Opis:
Due to the ending resources of fossil fuels, as well as instability of the political situation on the world, especially in countries that are their main supplier, governments of poor countries in resources are forced to seek alternative sources of energy. Currently the most commonly used raw material to produce an electrical and thermal power in Poland are coal and lignite, However, in a result of an increase of their prices and an exacerbated by the EU of regulations about an emission of the greenhouse gas, emerged trends, that aim to transform the energy sector through the implementation of technologies based on alternative energy sources. The main focus is to put on renewable energy sources. The methodology, which is contained in this paper, presents a way to designation the demand of the biogas plant with CHP system on substrate of agricultural origin, the aim to obtain required electrical and thermal power. Moreover, the paper presents a simplified diagram of anaerobic fermentation, which is the basis of biogas production, as well as an illustrative diagram of a biogas plant with CHP system. In this paper also was mentioned the possibility of application biogas for transportation purposes.
Źródło:
Journal of KONES; 2012, 19, 3; 334-344
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody arkhitekturno-stroitel'nykh reshenijj teplovaja effektivnost' zdanijj
Methods of architectural and construction solutions and thermal effectiveness of buildings
Autorzy:
Kulikov, G.
Kaz'mina, A.
Powiązania:
https://bibliotekanauki.pl/articles/77512.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
thermal effectiveness
solar energy
climatic factor
building parameter
microclimate
thermal power
thermal balance
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and economic study of the energy transition from natural gas to green hydrogen in thermal power plants
Autorzy:
Moulebe, Laince Pierre
Touati, Abdelwahed
Obar, Akpoviroro Eric
Belbsir, Oumayma
Rabbah, Nabila
Powiązania:
https://bibliotekanauki.pl/articles/27323589.pdf
Data publikacji:
2023
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
green hydrogen
thermal power plant
combustion
zielony wodór
elektrociepłownia
spalanie
Opis:
This research article contributes to the challenge of global warming by presenting the approach of the use of green hydrogen to reduce greenhouse gases. It shows that CO2 emissions can be significantly reduced in thermal power plants by replacing natural gas with green hydrogen as a fuel. This work presents the techno-economic study of the energy transition of a 12 MW thermal power plant based on green hydrogen. The presented study is based on the energy consumption of Nigeria, 73% of which is covered by natural gas thermal power plants. The obtained results show that the cost of this transition is ca. 17 million dollars (USD) for a reduction of 114 tCO2 per plant with a return on investment between 4-5 years. In addition, through modeling and numerical simulation, this article shows that estimated return on investment can be shortened by using the thermal power resulting from the turbine, through industrial use.
Źródło:
Acta Innovations; 2023, 49; 49--59
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of technical efficiency of heat and electric power generation
Autorzy:
Piwowarska, H.
Piwowarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/259361.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Data Envelopment Analysis (DEA)
technical efficiency
Malmquist index
thermal power generation
Opis:
This paper presents an evaluation of technical efficiency and time-dependent changes in productivity of Polish professional electric power and heat & electric power stations by using Data Envelopment Analysis non-parametric method. The research covered the enterprises whose total available electric power amounted to about 98% of that of all professional thermal electric power stations in this country. The analysis has concerned the years 2000÷2004. Impact was considered of such factors as: scale of enterprise activity, form of ownership as well as type of carried out activity, on technical efficiency and time-dependent productivity changes. Changes in productivity of the power generation sector were determined by means of Malmquist index.
Źródło:
Polish Maritime Research; 2009, S 1; 39-44
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of the Triad Approach to Ecological Assessment of the State of a Reservoir Receiving Wastewater From a Thermal Power Plant
Autorzy:
Mahanova, Elena
Powiązania:
https://bibliotekanauki.pl/articles/1839092.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
thermal power plant
chemical analysis of water
bioassay
bioindication
pollution
trophicity
Opis:
Thermal power plants (TPP) belong to the enterprises that accompany the development of any city. These industrial facilities consume and discharge large amounts of water. Therefore, thermal power plants are often located near water bodies that need to assess their ecological state and predict the consequences of the anthropogenic impact. The purpose of the work was to assess the ecological state of the floodplain Lake Ivanovskoye (Russia, Kirov region), which receives the wastewater from a thermal power plant, using a triadic approach and comparing the results of chemical analysis, bioassay and bioindication. It was shown that the main pollutant in the lake and the canal connecting Lake Ivanovskoye with the nearest river Vyatka is ammonium ion (up to 3.2 mg/dm3). In addition, the Russian standards for biological oxygen consumption are exceeded (analysis period is 20 days). The tests for the toxicity of wastewater showed inhibition of Paramecium caudatum and Escherichia coli reactions. In contrast, natural surface water from Lake Ivanovskoye stimulated the test functions of Scenedesmus quadricauda, P. caudatum, and E. coli. The death of Daphnia magna in the samples were not recorded. The totality of the facts pointed to the organic nature of pollution, leading to the anthropogenic eutrophication of the lake. The hypothesis was tested by using the bioindication method and by analyzing the totality of species of coastal aquatic plants. It was shown that the reservoir belongs to the mesotrophic type with a moderate degree of pollution, which decreases with distance from the wastewater discharge points. The increase in the trophicity of the reservoir is facilitated by thermal pollution (up to +15℃) and an alkaline pH of wastewater (up to 9.2). Thus, the joint analysis of the results of chemical analysis, bioassay and bioindication made it possible to carry out an objective assessment of the ecological state of the reservoir and identify the reasons for the revealed facts.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 155-160
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja wydajności urządzeń potrzeb własnych elektrowni cieplnych asynchronicznymi napędami falownikowymi średniego napięcia
Variable speed drives with frequency converters in thermal power plant auxiliaries
Autorzy:
Wawszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/173004.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia cieplna
napęd falownikowy
przemiennik
thermal power station
inverter drive
inverter
Opis:
Omówiono możliwości regulacji wydajności urządzeń potrzeb własnych elektrowni cieplnych napędzanych klatkowymi silnikami indukcyjnymi zasilanymi przemiennikami częstotliwości. Skupiono się głównie na napędach średnionapięciowych (6÷10 kV) dużej mocy. Przedstawiono aktualną ofertę przemienników czołowych światowych producentów. Oceniono możliwości wykorzystania tego typu napędów w dużych, nowoczesnych elektrowniach blokowych.
The paper introduces current potential of variable speed drives (VSD) intended for squirrel cage induction motors supplied by frequency converters in thermal power plant auxiliaries. The paper is mostly focused on medium-voltage (6-10 kV) and high-power drives. Current tender of leading world producers in this field has been presented. Possibility to apply this type of drives in large, modern block-power plants has been considered.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 87-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koordynacja układów regulacji generatorów i transformatorów elektrociepłowni przemysłowej
Autorzy:
Szczerba, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397382.pdf
Data publikacji:
2011
Wydawca:
ENERGA
Tematy:
układ regulacji
generator
transformator
elektrociepłownia przemysłowa
control system
transformer
thermal power station
Opis:
Generatory elektrociepłowni przemysłowych (zwykle w liczbie kilku) pracują równolegle, przyłączone do szyn zbiorczych 6 kV. Szyny zbiorcze 6 kV są połączone ze stacją 110 kV za pomocą co najmniej dwóch (zwykle kilku) transformatorów 110/6 kV. Układy regulacji generatorów są często nietrafnie nastawiane, a algorytmy działania regulatorów transformatorów 110/6 kV są nieprawidłowe, uniemożliwiając współpracę układów regulacji elektrociepłowni. W artykule podano propozycję koordynacji algorytmów działania układów regulacji.
Źródło:
Acta Energetica; 2011, 1; 51-57
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Structure on Thermal Power of Cast-iron Heat Exchangers
Autorzy:
Mróz, M.
Orłowicz, A. W.
Tupaj, M.
Jacek-Burek, M.
Radoń, M.
Kawiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/382256.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchanger
gray cast iron
thermal power
wymiennik ciepła
żeliwo szare
ciepło
Opis:
The objective of the study reported in this paper was to determine the effect of structure on thermal power of cast-iron heat exchangers which in this case were furnace chambers constituting the main component of household fireplace-based heating systems and known commonly as fireplace inserts. For the purpose of relevant tests, plate-shaped castings were prepared of gray iron with flake graphite in pearlitic matrix (the material used to date typically for fireplace inserts) as well as similar castings of gray cast iron with vermicular graphite in pearlitic, ferritic-pearlitic, and ferritic matrix. For all the cast iron variants of different structures (graphite precipitate shapes and matrix type), calorimetric measurements were carried out consisting in determining the heat power which is quantity representing the rate of heat transfer to the ambient environment. It has been found that the value of the observed heat power was affected by both the shape of graphite precipitates and the type of alloy matrix. Higher thermal power values characterize plate castings of gray iron with vermicular graphite compared to plates cast of the flake graphite gray iron. In case of plates made of gray cast iron with vermicular graphite, the highest values of thermal power were observed for castings made of iron with ferritic matrix.
Źródło:
Archives of Foundry Engineering; 2020, 20, 1; 27-30
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the turbogenerator regulation systems
Autorzy:
Kisielewski, P.
Gozdowiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1368630.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
field-circuit modeling
finite element method
regulation systems
thermal power plant
turbogenerator
Opis:
This paper presents the ability to connect field-circuit model of the turbogenerator with regulation systems in power plant. An excitation and a turbine regulator were used in modeling of the power plant regulation system. This article is being considered for thermal power stations.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 69-72
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrownia siersza wodna (1913-1962)
Siersza Wodna Power Plant (1913-1962)
Autorzy:
Kwiatkowski, Marian
Powiązania:
https://bibliotekanauki.pl/articles/1199204.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Siersza
Historia elektrowni
Elektrownia cieplna
Elektrownia okręgowa
History of power plant
Thermal power plant
District power plant
Opis:
Thermal power plant Siersza Wodna, put into operation in 1913, was the first district power plant in Galicia. Its main task was generation of electrical energy and its distribution to end clients. That feature differentiated Siersza Wodna from other company power plants the main task of which was to generate electricity for the company; distribution to external users was a secondary task. The plant was financed from Polish and Austrian resources and soon became the drive for the growth of western Lesser Poland. Its location, close to Galicia Mining company in Siersza, enabled combustion of coal dust and sludge which were difficult to sell. The plant’s initial capacity amounted to 2 x 2.5 MW. Later the capacity increased to 22.5 MW as the plant obtained more government permits and the electrification of the area advanced. At the beginning of 1920s, the plant was purchased by Siła i Światło (Power and Light Company). As part of the company, Siersza Wodna, among other power plants, was to constitute Krakow Electrification District. The outbreak of WWII thwarted these plans. After the war the company took active part in electrification of Krakow voivodship, nonetheless the wear and tear as well as the war damage prevented longer operation of the plant. It was shut down in 1962. An energy utility operates on the premises of former Siersza Wodna. Employess commenced work in the newly-constructed Siersza Power Plant. Siersza Wodna Power Plant significantly contributed to the electrification of western Little Poland as well as education of a large number of power engineers in the region.
Elektrownia cieplna Siersza Wodna uruchomiona w 1913 roku była pierwszą elektrownią okręgową Galicji. Jej głównym zadaniem była produkcja energii elektrycznej i zasilanie nią chętnych odbiorców. To właśnie różniło ją od elektrowni przyzakładowych, dla których głównym celem było zasilanie macierzystego zakładu, a dopiero później, w miarę posiadanych mocy, zasilanie innych odbiorców. Zbudowana przy udziale kapitału polskiego i austriackiego, została motorem rozwoju zachodniej Małopolski. Jej usytuowanie w bezpośrednim sąsiedztwie kopalni węgla „Galicyjskich Akcyjnych Zakładów Górniczych w Sierszy” pozwalało na spalanie miałów i mułów, na które kopalnia nie miała zbytu. Jej początkowa moc wynosiła 2 x 2,5 MW i przez lata w miarę uzyskiwania uprawnień rządowych, zwiększania terenu elektryfikowanego, wzrosła do 22,5 MW. Z początkiem lat 20. ubiegłego wieku została zakupiona przez koncern „Siła i Światło”. W ramach tej spółki miała być jedną z elektrowni tworzących Krakowski Okręg Elektryfikacyjny. Wybuch II wojny światowej pokrzyżował te plany. Po odzyskaniu niepodległości aktywnie uczestniczyła w elektryfikacji województwa krakowskiego. Zużycie wojenne i stan techniczny nie pozwolił jej na dłuższą pracę. Wyłączona została w 1962 roku. Na jej terenie funkcjonuje obecnie zakład energetyczny. Kadra elektrowni przeszła do budowanej wówczas Elektrowni Siersza. Elektrownia Siersza Wodna wniosła olbrzymi wkład w elektryfikację Małopolski Zachodniej i w utworzenie kadry energetyków tego regionu.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 4, 116; 151-157
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uelastycznienie pracy bloku parowego klasy 200 MW źródłem geotermalnym
Autorzy:
Badur, Janusz
Kowalczyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/89378.pdf
Data publikacji:
2018
Wydawca:
Nowa Energia
Tematy:
elektrownia cieplna
blok parowy
źródło geotermalne
thermal power station
steam unit
geothermal source
Opis:
W artykule przedstawiono możliwość wykorzystania źródła geotermalnego do wspomagania pracy bloku parowego klasy 200 MW. Zaproponowane rozwiązanie zmniejsza zużycie węgla i poprawia elastyczność pracy bloku, którą można dodatkowo rozszerzyć przy zastosowaniu magazynów ciepłej wody lub akumulacji ciepła w gruncie podczas jego termicznej regeneracji.
Źródło:
Nowa Energia; 2018, 1; 73-75
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the Efficiency of Treatment Model Mixtures of Petroleum Products with the Modified Sorbent Made of Ash-and-Slag During Dynamic Sorption
Autorzy:
Korotkova, Tatyana Germanovna
Bushumov, Svyatoslav Andreevich
Ksandopulo, Svetlana Yurevna
Solonnikova, Nataliya Vladimirovna
Powiązania:
https://bibliotekanauki.pl/articles/123373.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ash and slag
thermal power plant
sorbent
sorption dynamics
efficiency
petroleum products
extraction
Opis:
Experimental studies on the dynamic sorption of model mixtures containing petroleum products were performed. The subject of the study was the modified sorbent from the ash-and-slag wastes accumulated in the ash dump of the Novocherkassk State District Power Plant (SDPP) (Russia, Novocherkassk, Rostov Region), obtained using the method of ash removal. The quantity of the sorbent for each model solution was fixed at 5.0 g. The model solutions in the amount of 1 dm3 were passed through a column filled with the modified sorbent at constant filtration rate w = const with filtrate takeout of 0.1 dm3/min. The pH value of the solution, which is advisable for extracting petroleum products, was determined experimentally. For this purpose, the model solutions, containing 100 mg/dm3 of petroleum products with pH = 1.65, 4.01, 6.86, 8.12, 9.18, and 11.34, were prepared. The optimum pH value of the solution was considered pH = 7.5. The content of petroleum products in the filtrate in all experiments was determined using IR spectrometry. The working range of water pollution with petroleum products was determined on a series of model solutions containing petroleum products in the range between 0.5 and 10 mg/dm3 with the increment of 0.5, between 10 and 100 mg/dm3 with the increment of 10, and between 100 and 1,000 mg/dm3 with the increment of 100. The maximum extraction of petroleum products from the solution was 88.23%. The applicability of the Henry’s law to the range of petroleum products concentrations in the filtrate of 50 mg/dm3 was confirmed. The adsorption equilibrium constant (Henry’s law constant) was determined experimentally. The effect of the natural freshwater matrix on the degree of petroleum products extraction was studied; no significant effect on petroleum products sorption was found. A conclusion was made that the sorbent can ensure the efficiency of water purifying from petroleum products of no less than 85% in the range of pollution between 5 and 300 mg/dm3.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 202-209
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detailed Energy Audit of Thermal Power Plant Equipment
Autorzy:
Das, Sourabh
Mukherjee, Mainak
Mondal, Surajit
Powiązania:
https://bibliotekanauki.pl/articles/1193916.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Energy Audit
Energy Conservation
Lighting Audit
Motor Audit
Pump Audit
Thermal Power Plant
Transformer Audit
Opis:
Energy audit is a technique developed to reduce unnecessary usage of energy, control and also streamline processes leading to energy efficiency. Energy audit and its impact on a daily basis is high and hence is of good significance. Energy Conservation over the years has been a key in terms of saving excessive bills and building up unnecessary usage both domestically and industrially. The world is not completely energy efficient yet, it should be a made sure that the process to ensure optimum usage and saving wherever possible. In this paper we shall discuss in brief about energy audit in a thermal power plant, techniques and ways data are obtained. India’s strive for complete energizing is yet on the verge of completion, need for saving unused energy and also recovering waste energy can be beneficial in developing an energy content environment. The energy audit carried out in thermal power plant gives a presentation of the data and corners of collecting data.
Źródło:
World Scientific News; 2015, 22; 70-90
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ceramics Materials with Addition of Ashes from Combustion of Coal in Thermal Power Plants
Materiały ceramiczne z dodatkiem popiołów ze spalania węgla w elektrowniach termicznych
Autorzy:
Michalikova, F.
Brezani, I.
Sisol, M.
Skvarla, J.
Kozakova, L.
Powiązania:
https://bibliotekanauki.pl/articles/318233.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
ceramics
fly ash
solid wastes
thermal power plant
ceramika
popioły lotne
odpady stałe
elektrownia termiczna
Opis:
This article reviews results of an experimental study aimed to evaluate the possibility of using ashes - solid wastes from combustion of brown coal in fluid and granulation boilers as one of the ingredients in ceramics production. Results of testing of the ashes from different combustion processes – combustion of slovak brown coal in granulation and fluid boilers and their usage as a components in dark ceramics showed partial usability in this field. These test consisted of firing the ashes in electric laboratory oven and in industrial fast firing oven. Sample (83) of brown coal fluid bed ash has low Fe content, material has light brown color at temperatures 1100 – 1190 °C after partial melting. Sample (84) with fluid fly ash has higher Fe content, resulting in dark brown color. Both of the samples from fluid combustion of coal require higher temperature for partial melting than 1190 °C. Sample (85) of stabilizate – product of desulphurization – was at the same temperature of 1100 °C completely molten. Sample (86) of granulation ash at the same temperature conditions expanded during firing. Results of this testing practice have proven, that tested ashes have high content of coloring oxides, mainly iron oxide, which results in red up to brown color of the ceramic material. Because of high CaO content in fluid ashes they can only be used as an additive of porous ceramic materials. Use of the tested ashes in compounds prepared using similar procedures as the industrial compounds resulted in higher suction capacity. Our tests have proven the possibility of using fluid bed ash as an opening material, fly ash as a partial replacement of opening material and melting ingredient, desulphurization product as a partial replacement of melting ingredient. Laboratory tests confirmed usability of granulation ashes as an ingredient in dark colored tile manufacture.
W artykule dokonano przeglądu wyników badania eksperymentalnego, mającego na celu ocenę możliwości wykorzystania popiołów - odpadów stałych ze spalania węgla brunatnego, w kotłach fluidalnych i granulacyjnych jako jednego ze składników w produkcji wyrobów ceramicznych. Wyniki badań popiołów z różnych procesów spalania - spalanie słowackiego węgla brunatnego w kotłach granulacyjnych i fluidalnych, oraz ich użycie jako składników w ciemnych wyrobach ceramicznych, wykazały częściową użyteczność w tej dziedzinie. Test składał się z wypalania popiołów w elektrycznym piecu laboratoryjnym oraz w przemysłowym piecu do szybkiego wypalania. Próbki (83) popiołów z węgla brunatnego ze złoża fluidalnego mają niską zawartość Fe, materiał ma jasnobrązowy kolor w temperaturze 1100 - 1190°C po częściowym stopieniu. Próbki (84) popiołu lotnego ze złoża fluidalnego mają wyższą zawartość Fe, co w rezultacie daje ciemnobrązowy kolor. Obie grupy próbek z fluidalnego spalania węgla wymagają do ich częściowego stopienia temperatury wyższej niż 1190°C. Próbki (85) ze stabilizatu - produktu odsiarczania - były w temperaturze 1100°C całkowicie stopione. Próbki (86) popiołu z granulacji w tych samych warunkach temperaturowych, rozszerzyły się w czasie wypalania. Wyniki tego badania wykazały że, w praktyce, badane popioły maja wysoką zawartość tlenków barwiących, głównie tlenku żelaza, co prowadzi do uzyskania czerwono-brązowego koloru materiału ceramicznego. Ze względu na wysoką zawartość CaO w popiele ze złoża fluidalnego, mogą być one używane tylko jako dodatku do porowatych materiałów ceramicznych. Wykorzystanie badanych popiołów w związkach przygotowanych przy użyciu podobnych procedur jak w przypadku związków przemysłowych spowodowało wzrost zdolności zasysania. Testy wykazały możliwość wykorzystania popiołu ze złoża fluidalnym jako materiału otwierającego, popiołu lotnego jako częściowo zastępującego materiał otwierający i topliwy, produkt odsiarczania jako częściowe zastąpienie substancji topliwej. Badania laboratoryjne potwierdziły przydatność popiołów granulacyjnych jako składnika w produkcji płytek o ciemnym kolorze.
Źródło:
Inżynieria Mineralna; 2014, R. 15, nr 2, 2; 15-22
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining steam condensation pressure in a power plant condenser in off-design conditions
Autorzy:
Laskowski, Rafał
Smyk, Adam
Ruciński, Adam
Szymczyk, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1954999.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power plant
steam condenser
condenser model
steam condensation
pressure
reference parameters
steam condenser effectiveness
Opis:
The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ożebrowania rury na warunki wymiany ciepła przy konwekcji swobodnej w powietrzu
The influence of fins on heat transfer performance under free convection in air
Autorzy:
Tychanicz-Kwiecień, Maria
Mazur, Aleksandra
Gil, Paweł
Gałek, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/195178.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
powierzchnie ożebrowane
przenikanie ciepła
konwekcja swobodna
moc cieplna
fins
heat transfer
free convection
thermal power
Opis:
Artykuł przedstawia wstępne wyniki pomiarów cieplnych rurowego wymiennika ciepła typu woda–powietrze, wykonanego z odcinków rur gładkich oraz ożebrowanych z żebrami śrubowymi. Stanowisko pomiarowe znajduje się na wyposażeniu Zakładu Termodynamiki Wydziału Budowy Maszyn i Lotnictwa Politechniki Rzeszowskiej. Dokonano pomiarów mocy cieplnej traconej przez przenikanie na rurze gładkiej oraz ożebrowanej w funkcji różnicy temperatury wody wlotowej i temperatury otoczenia oraz współczynników przenikania ciepła: rury gładkiej – odniesionego do powierzchni zewnętrznej oraz dla rury ożebrowanej – odniesionego do powierzchni całkowitej ożebrowania. Wyniki pomiarów wskazują, że moc cieplna rozpraszana do otoczenia wzrasta niemal trzykrotnie w wyniku zastosowania ożebrowania w stosunku do powierzchni gładkiej. Z kolei współczynnik przenikania ciepła określony dla rury gładkiej osiągnął wartość wielokrotnie większą niż dla rury ożebrowanej.
The article presents preliminary results of thermal parameter measurements of an air-water tubular heat exchanger made of smooth- and finned pipes. The experimental set-up is the equipment of The Department of Thermodynamics at Rzeszow University of Technology. The following parameters have been measured as a function of temperature difference between inlet water temperature and ambient temperature: dissipated thermal power for smooth- and finned pipes and the heat transfer coefficient for a smooth pipe related to the external surface and heat transfer coefficient for a finned pipe related to the overall finned surface. The results indicate that dissipated thermal power increased almost three times for the finned pipe with regard to the smooth pipe. The heat transfer coefficient obtained for a smooth pipe was considerably greater than for a finned pipe.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2019, z. 91 [299], 1-2; 93-107
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recurrent Neural Networks for Predictive Maintenance of Mill Fan Systems
Autorzy:
Koprinkova-Hristova, P. D.
Hadjiski, M. B.
Doukovska, L. A.
Beloreshki, S. V.
Powiązania:
https://bibliotekanauki.pl/articles/226304.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
technical diagnosis
Thermal Power Plant (TPP)
Recurrent Neural Networks (RNN)
distributed control system (DCS)
predictive maintenance
Opis:
In the present paper we focus on online monitoring system for predictive maintenance based on sensor automated inputs. Our subject was a device from Maritsa East 2 power plant - a mill fan. The main sensor information we have access to is based on the vibration of the nearest to the mill rotor bearing block. Our aim was to create a (nonlinear) model able to predict on time possible changes in vibrations tendencies that can be early signal for system work deterioration. For that purpose, we compared two types of recurrent neural networks: historical Elman architecture and a recently developed kind of RNN named Echo stet networks (ESN). The preliminary investigations showed better approximation and faster training abilities of ESN in comparison to the Elman network. Direction of future work will be increasing of predications time horizon and inclusion of our predictor at lower level of a complex predictive maintenance system.
Źródło:
International Journal of Electronics and Telecommunications; 2011, 57, 3; 401-406
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Pollutants Emission into the Air at the Stage of an Electric Vehicle Operation
Autorzy:
Marczak, Halina
Droździel, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1955495.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
electric car
efficiency of thermal power plants
emissions from vehicles
electricity from coal
vehicle operation stage
Opis:
The article discusses the research on CO2 emissions at the stage of electric engine vehicle operation. The operation stage includes, among others use of the vehicle as well as maintenance and charging for the vehicle’s propulsion. The origin of the electricity consumed during charging has an impact on the vehicle’s emissions balance. The scope of considerations concerns coal as the main energy carrier in Poland. The obtained results can be a benchmark for comparing other primary energy sources used for electricity production. Based on the collected technical data of electric cars, the values of CO2 emission factors from electricity production in thermal power plants and data on the state and structure of electricity production in Poland, an analysis of CO2 emissions from electric vehicles in the operational stage was performed. The vehicle’s electricity consumption of 0.14–0.16 kWh/km is accompanied by CO2 emissions of 100.94–115.36 g/km. The calculated CO2 exceeds the EU limit value from 01/01/2020 (95 g/km) for average CO2 emissions from new passenger vehicles. The main message of the work is the statement that increasing the efficiency of the electricity generation process in commercial thermal power plants in Poland will translate into a reduction in the emission of electric cars consuming this energy for propulsion. The research shows that the change in the efficiency of energy transformations in a thermal power plant from 38% to 46% leads to a reduction in the emission of an electric vehicle by over 17%. The emission of CO2 from a passenger car with a compression-ignition engine is discussed. The considerations include the stage of the use of the vehicle and the stage of production of diesel oil, which is consumed during the use of the vehicle.
Źródło:
Journal of Ecological Engineering; 2021, 22, 8; 182-188
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of damping characteristics and index evaluation of a wind-PV-thermal-bundled power transmission system by combining PSS and SSSC
Autorzy:
He, Ping
Wu, Xinxin
Li, Congshan
Zheng, Mingming
Li, Zhao
Powiązania:
https://bibliotekanauki.pl/articles/140453.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damping characteristics
eigenvalue analysis
power system stabilizer
wind-PV-thermal-bundled power system
Opis:
The grid integration of large-scale wind and solar energy affects the power flow of wind-PV-thermal-bundled power transmission systems and may introduce an unpredicted threat to the power system’s small signal stability. Meanwhile, a power system stabilizer (PSS) and static synchronous series compensator (SSSC) play an important role in improving the static and dynamic stability of the system. Based on this scenario and in view of the actual engineering requirements, the framework of wind-PV-thermal-bundled power transmitted by an AC/DC system with the PSS and SSSC is established considering the fluctuation of wind and photovoltaic power output and the characteristics of the PSS and SSSC. Afterwards, the situation model is constructed in the IEEE 2-area 4-unit system, and the influence of the PSS and SSSC on the system stability under different operating conditions is analyzed in detail through eigenvalue analysis and time-domain simulation. Finally, an index named the gain rate is defined to describe the improvement of the stability limitations of various wind-PV-thermal operating conditions with the PSS and SSSC. The results indicate (K) that the damping characteristics, dynamic stability and stability limitations for various wind-PV-thermal operating conditions of the wind-PV-thermal-bundled power transmission system can be significantly improved by the interaction of the PSS and SSSC.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 705-721
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiz poroga ekonomiceskoj celesoobraznosti ekspluatacii TES i puti ich vozmoznoj modernizacii na primere vnedrenia castotnych preobrazovatelej dla pitatel’nych elektronasosov
Analysis of an economic feasibility threshold of TPP and ways of possible modernization of TPP on the example of the introduction of frequency converters for feeding pumps
Autorzy:
Pogosov, A.
Prijmak, A.
Malkin, E.
Kulinko, E.
Powiązania:
https://bibliotekanauki.pl/articles/2065364.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska
Tematy:
pompy zasilające
turbiny parowe
regulacja częstotliwości
moc termiczna
thermal power plant
steam turbine
feeding pump
frequency regulation
Opis:
V stat’e privedeny rezul’taty analiza poroga ekonomiceskoj celesoobraznosti ekspluatacii teplovych elektrostancij, kotoryj pozvolaet opredelit’ ekonomiceski obosnovannye sroki podlenia raboty TES, a takze pokazyvaet rentabel’nyj uroven’ zatrat topliva na vyrabotku elektriceskoj energii. Vo vtoroj casti stat’i privedeny techniko-ekonomiceskie pokazateli vnedrenia castotnych preobrazovatelej dla pitatel’nych elektronasosov, kak odin iz celesoobraznych sposobov modernizacii TES.
This article presents the results of the economic feasibility analysis of the threshold operation of thermal power plants (TPP). The determination of an economic feasibility threshold makes it possible to estimate an economically reasonable extension of TPP lifetime and shows reasonable fuel cost level for electricity generation. The second part of the article shows the technical and economic performance of an introduction of frequency converters for feeding pump as one of the appropriate methods of modernization of TPP.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2015, 2 (16); 63--69
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Microstructure and Heat Transfer Surface on the Thermal Power of Cast Iron Heat Exchangers
Autorzy:
Mróz, M.
Orłowicz, A. W.
Tupaj, M.
Lenik, M.
Kawiński, M. J.
Kawiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/2079819.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vermicular cast iron
heat exchanger
thermal power
calorimetric test
żeliwo wermikularne
wymiennik ciepła
moc cieplna
test kalorymetryczny
Opis:
The paper presents the results of calorimetric tests of segment elements of fireplace inserts. The aim of the work was to optimize their thermal power by replacing the previously used gray cast iron with flake graphite with gray iron with vermicular graphite and replacing the existing geometry of the heat transfer surface with a more developed one. It turned out that the thermal power of the test segments made of cast iron with vermicular graphite was higher compared to the segments of the same shape made of gray cast iron with flake graphite. It was found that the use of segments made of vermicular cast iron with a ferritic matrix allowed for an increase in the thermal power value by dozen percent, compared to segments of the same shape made of vermicular cast iron with a pearlitic matrix. The test results showed that the thermal power of the test segments depends on the variant of the development of both the heat receiving surface and the heat giving off surface. The highest value of the thermal power was obtained when ribbing in the form of a lattice was used on both of these surfaces, and the lowest when using flat surfaces.
Źródło:
Archives of Foundry Engineering; 2021, 21, 4; 93-96
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving flexibility characteristics of 200 MW unit
Autorzy:
Taler, J.
Trojan, M.
Taler, D.
Dzierwa, P.
Kaczmarski, K.
Powiązania:
https://bibliotekanauki.pl/articles/239919.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power unit
flexibility increasing
steam boiler
rapid start-up
elektrownia cieplna
elastyczność
kocioł parowy
szybkie uruchamianie
Opis:
Calculations were performed of the thermal system of a power plant with installed water pressure tanks. The maximum rise in the block electric power resulting from the shut-off of low-pressure regenerative heaters is determined. At that time, the boiler is fed with hot water from water pressure tanks acting as heat accumulators. Accumulation of hot water in water tanks is also proposed in the periods of the power unit small load. In order to lower the plant electric power in the off-peak night hours, water heated in low-pressure regenerative heaters and feed water tank to the nominal temperature is directed to water pressure tanks. The water accumulated during the night is used to feed the boiler during the period of peak demand for electricity. Drops in the power block electric power were determined for different capacities of the tanks and periods when they are charged. A financial and economic profitability analysis (of costs and benefits) is made of the use of tanks for a 200 MW power unit. Operating in the automatic system of frequency and power control, the tanks may also be used to ensure a sudden increase in the electric power of the unit. The results of the performed calculations and analyses indicate that installation of water pressure tanks is well justified. The investment is profitable. Water pressure tanks may not only be used to reduce the power unit power during the off-peak night hours and raise it in the periods of peak demand, but also to increase the power capacity fast at any time. They may also be used to fill the boiler evaporator with hot water during the power unit start-up from the cold state.
Źródło:
Archives of Thermodynamics; 2017, 38, 1; 75-90
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat power determination of Dv-290 refrigerator’s evaporator on the basis of thermodynamic parameters of inlet air
Określenie mocy cieplnej parownika chłodziarki Dv-290 na podstawie parametrów termodynamicznych powietrza wlotowego
Autorzy:
Nowak, B.
Kuczera, Z.
Powiązania:
https://bibliotekanauki.pl/articles/218808.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
chłodziarka sprężarkowa
moc cieplna
air conditioning of mines
air cooling
compression refrigerator
thermal power
Opis:
The present paper introduces a method for calculating the thermal power of DV-290 mining air cooler’s evaporator. The power usually differs from the nominal power given by the manufacturer. The thermodynamic parameters of cooled air are not obtained as a result of in situ measurements, but in indirect manner that is by determining the evaporation and condensation’s pressure values of R407C refrigerant. The pressure dependencies formulated as a function of air enthalpy at the evaporator’s inlet were obtained using calculations of a computer program which solves the system of equations describing heat and mass transfer in the refrigerator’s compressor on the basis of previous measurements of air performed before and after its cooling. The obtained dependencies are demonstrated in a graphical (fig. 2 and fig. 3) and analytical (the regression equations (19) and (20)) manner, the values of correlation coefficients are also presented. For the known evaporation and condensation pressure values of the refrigerant, and thus for its basic physical parameters the complete thermal power of the evaporator was determined, that is its: air cooling overt power, dehumidification occult power, temperature, relative humidity and specific humidity of air after its cooling. In addition, using the mentioned method, the capacity of DV-290 refrigerator’s evaporator is provided for the given thermodynamic parameters of air before cooling, along with air thermodynamic parameters after cooling.
W pracy zaproponowano metodę obliczania mocy cieplnej parownika górniczej chłodziarki powietrza DV-290. Moc ta zazwyczaj jest różna od mocy znamionowej podanej przez jej producenta. Wymaganą znajomość parametrów termodynamicznych schłodzonego powietrza otrzymuje się, nie jak dotychczas w wyniku ich pomiarów in situ, lecz drogą pośrednią wyznaczając najpierw wartości ciśnień parowania i skraplania czynnika chłodniczego R407C. Odpowiednie zależności tych ciśnień w funkcji jednostkowej entalpii powietrza na wlocie parownika otrzymano, na podstawie wcześniejszych pomiarów parametrów powietrza przed i po jego schłodzeniu, z obliczeń utworzonym programem komputerowym rozwiązującym układ równań opisujący wymianę ciepła i masy w chłodziarce sprężarkowej. Uzyskane zależności przedstawiono w sposób graficzny (rys. 2 i rys. 3) oraz analityczny - równania regresji (19) i (20), podając też wartości współczynników korelacji. Dla znanych wartości ciśnień parowania i skraplania czynnika chłodniczego, a więc także i jego podstawowych parametrów fizycznych, korzystając z wymienionego programu komputerowego, wyznaczono, w funkcji jednostkowej entalpii powietrza na wlocie parownika, całkowitą jego moc cieplną z podziałem na moc jawną ochładzania powietrza, utajoną moc osuszania powietrza, temperaturę, wilgotność względną i wilgotność właściwą powietrza po jego ochłodzeniu. Podano też, dla przykładowych zadanych parametrów termodynamicznych powietrza przed jego schłodzeniem obliczone wspomnianą metodą, moce parownika chłodziarki DV-290 oraz parametry termodynamiczne powietrza po schłodzeniu.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 911-920
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of a high-forced cooling system for the elements of heat power installations
Autorzy:
Genbach, A. A.
Bondartsev, D. Y.
Iliev, I. K.
Powiązania:
https://bibliotekanauki.pl/articles/100148.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
heat transfer control
capillary-porous coatings
natural mineral media
heat-transfer crisis
capillary-porous system
thermal power plants
Opis:
The studies of the ultimate thermal flows have been carried out in metallic and poorly heat-conducting porous structures, which operate when gravitational and capillary forces act jointly and cool various devices of thermal power plants in order to create a scientific methodology. The mechanism of destruction of metal vaporizing surfaces and poorly heat-conducting coatings of low porosity made of natural mineral media (granite) has been described on the basis of the problem of thermoelasticity and experimental data. Thermal flow dependences on time of their action and depth of penetration of temperature perturbations were identified based on analogy. Capillary-porous systems have high intensity, heat transport ability, reliability, compactness. The results of calculations and experiment showed that the maximum thickness of the particles that detach under the influence of compression forces for granite coatings is (0.25÷0.3).10-2 m. Sections of compression curves that determine the detachment of particles with dimensions of more than 0.3×10-2 m for large thermal flows and short feed times, are screened by the melting curve, and in the case of small thermal flows and time intervals – the expansion curve.
Źródło:
Journal of Machine Engineering; 2018, 18, 2; 106-117
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Analysis of Thermal Properties of Selected Rock Materials by Thermovision Methods
Analiza właściwości cieplnych wybranych surowców naturalnych, na podstawie badań wykorzystujących metody termowizyjne
Autorzy:
Stempkowska, A.
Izak, P.
Mastalska-Popławska, J.
Staszewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/319117.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
ciepło właściwe minerałów
emisja ciepła
termiczne właściwości skał
moc cieplna
termowizja
minerals specific heat capacity
heat emission
rocks thermal properties
thermal power
thermovision
Opis:
Heat accumulation means denotes the of a material to collect and store inside a specific amount of thermal energy, which can be then returned for a period time from the material. There are many investigations devoted to finding a method to collect heat when there is an excess and to use it when there is a deficit. The parameter determining whether the returned heat long for a term will have an impact on the room temperature, is the time of emission of stored energy. For the specified amount of stored energy, the emission time cannot be too short (in such a case too much heat in the unit time is returned) or too long (in this case a too small amount of heat in the time unit is returned, for example insufficient for heating rooms). The main aim of this research is to investigate the behavior (during cooling) of natural rock materials. On the basis of research and performed calculations the evaluation of tested materials to serve as the heat accumulator was performed. This analysis would allow them to be applied for the production of components, including precast, working at elevated temperatures, in which the accumulation and transfer of heat is important (eg. housing furnaces and fireplaces).
Akumulacja ciepła oznacza zdolność materiału do gromadzenia i magazynowania w jego wnętrzu określonej porcji energii cieplnej, która następnie może być przez pewien okres czasu przez ten materiał oddawana. Szuka się więc sposobów gromadzenia ciepła wtedy, gdy jest jego nadmiar oraz wykorzystania, gdy występuje deficyt. Parametrem, decydującym o tym czy oddający ciepło materiał w sposób długotrwały będzie oddziaływał na temperaturę pomieszczenia, jest czas oddawania (emisji) zgromadzonej energii. Przy danej ilości zgromadzonej energii, czas jej emisji nie może być zbyt krótki (wtedy w jednostce czasu oddawane są zbyt duże ilości ciepła) ani zbyt długi (wtedy w jednostce czasu oddawane są zbyt małe ilości ciepła, niewystarczające np. do ogrzania pomieszczenia). W niniejszej pracy zrelacjonowano eksperyment polegający na badaniu zachowania się, podczas studzenia, naturalnych surowców mineralnych. Na tej podstawie badań oraz wykonanych obliczeń oceniono jego zdolność do akumulacji cieplnej. Pozwoliłoby to na stosowanie ich do wytwarzania elementów, w tym prefabrykatów, pracujących w podwyższonych temperaturach, gdzie jest istotna akumulacja i oddawanie ciepła (np. obudowy palenisk i komików).
Źródło:
Inżynieria Mineralna; 2018, R. 20, nr 2, 2; 337-344
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection and calculation of air cooling solutions in underground coal mines in Vietnam
Dobór i obliczenia rozwiązań chłodzenia powietrza w podziemnych kopalniach węgla w Wietnamie
Autorzy:
Borowski, Marek
Trung Tien, Quan
Łuczak, Rafał
Życzkowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1841452.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
air temperature
air humidity
air cooling
thermal power of cooler
temperatura powietrza
wilgotność powietrza
chłodzenie powietrza
moc cieplna chłodnicy
Opis:
Currently, Vietnamese underground mines have been exploited down to -500 m and, in the near future, they will be exploited deeper. The exploitation of coal of seams has an negative impact on a workers environment. The increase in the depth of coal seam exploitation causes is the increase of adverse microclimate factors such as temperature, moisture, heat radiation. According to the current Viet¬namese laws, coal deposits can be mined in a condition when air temperature does not exceed 30oC, although this rule is not always observed, especially during summer. The article show how reducing the adverse impact of climate factors in the mines and calculating the parameters which reduce the temperature on an example in one of underground coal mines in Vietnam.
Obecnie wietnamskie kopalnie podziemne zostały wyeksploatowane do -500 m, w najbliższej przyszłości będą eksploatowane głębiej. Eks¬ploatacja ma negatywny wpływ na środowisko. Działalność eksploatacji w wyrobiskach powoduje wzrost niekorzystnych czynników mi-kroklimatycznych, takich jak temperatura, wilgotność, promieniowanie cieplne. Zgodnie z obowiązującym wietnamskim prawem, złoża węgla mogą być eksploatowane w warunkach, gdy temperatura powietrza nie przekracza 30°C, chociaż nie zawsze jest to przestrzegane, zwłaszcza latem. W artykule przedstawiono rozwiązanie ograniczania niekorzystnego wpływu czynników klimatycznych w kopalniach oraz obliczenie parametrów obniżających temperaturę powietrza na przykładzie podziemnych kopalń węgla w Wietnamie.
Źródło:
Inżynieria Mineralna; 2020, 2, 2; 237-244
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ewolucja kryteriów wyboru i wartości temperatury obliczeniowej powietrza zewnętrznego dla ogrzewnictwa w Polsce
Autorzy:
Narowski, P
Powiązania:
https://bibliotekanauki.pl/articles/363008.pdf
Data publikacji:
2011
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
temperatury obliczeniowe powietrza zewnętrznego
projektowanie zapotrzebowania na moc do ogrzewania i chłodzenia budynków
design temperatures of air
thermal power demand
cooling power demand
Opis:
Wartości temperatury obliczeniowej powietrza zewnętrznego mają podstawowe znaczenie w procesie wyznaczania zapotrzebowania na moc cieplną dla budynków oraz wpływają na proces projektowania i wymiarowania urządzeń ogrzewczych. W Polsce ostania modyfikacja normy dotyczącej obliczeniowych temperatur zewnętrznych dla ogrzewnictwa miała miejsce w 1982 roku, jakkolwiek wartości te nie zmieniały się od kilkudziesięciu lat. Dostępne obecnie dane meteorologiczne z wielolecia dla 61 stacji meteorologicznych, normy europejskie dotyczące danych klimatycznych wykorzystywanych w budownictwie, komputerowe systemy symulacji energetycznych budynków oraz coraz nowocześniejsze technologie stosowane w budownictwie zmuszają do zastanowienia się nad weryfikacją obecnie wykorzystywanych temperatur obliczeniowych dla ogrzewnictwa. W prezentowanym artykule przedstawione zostaną zmiany w doborze kryteriów wyboru oraz wartości temperatury obliczeniowej dla ogrzewnictwa w Polsce na przestrzeni lat.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2011, T. 6, nr 3, 3; 61-67
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of various control techniques for motor-pump sets applied in selected water distribution systems
Autorzy:
Popenda, A.
Powiązania:
https://bibliotekanauki.pl/articles/1372738.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
elektrociepłownia
system dystrybucji wody
pompa
thermal-electric power station
water distribution system
pump
Opis:
The water distribution system applied in the thermal-electric power station EC Tychy SA is analyzed. The economical aspects of various control techniques for motor-pump sets in the aforementioned system are presented in the paper on the example of pumps working out of the cold season. The reasons of control losses occurring in the present system are depicted. The way of improvement of control effectiveness is proposed but unprofitability of the investment is also shown. A control of pumps by throttling and control by rotational speed changes are compared in the paper. It is shown that control by rotational speed changes causes similar losses like control by throttling if application of variable-speed technique is not preceded by appropriate adaptation of water distribution system, especially by adjustment of pump rated parameters.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2011, 4, 92; 97-101
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zagrożeń środowiska pracy w elektrowniach cieplnych-węglowych
Analysis of work environment hazards at the thermal power plants – coal-based
Autorzy:
Bajdur, W.M.
Mrówczyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/103688.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
czynniki chemiczne
czynniki fizyczne
czynniki psychofizyczne
elektrownie cieplne
eliminacja zagrożeń
chemical factor
physical factor
psychophysical factors
thermal power plants
hazards elimination
Opis:
Jednym z najważniejszych zagadnień dotyczących środowiska pracy jest identyfikacja i analiza zagrożeń. Zagrożenia określamy na podstawie pomiaru częstości i ilości różnorodnych czynników występujących w środowisku pracy. Pracodawca wskazuje czynniki szkodliwe po przeprowadzeniu rozpoznania źródeł emisji oraz warunków wykonywania pracy, które mają wpływ na poziom stężeń lub natężeń tych czynników lub na poziom narażenia na oddziaływanie tychże. W elektrowniach cieplnych produkujących energię elektryczną z paliw kopalnych (węgiel) prowadzi się badania i pomiary praktycznie większości czynników z grup czynników fizycznych i chemicznych, na które może być narażony pracownik w środowisku pracy. W artykule przedstawiono identyfikację zagrożeń w elektrowni cieplnej i dokonano ich analizy z uwzględnieniem metod eliminacji tych zagrożeń.
One of the most essential issue regarding work environment is identification and analysis of hazards. Hazards are defined based on measurement of frequency and number of various factors occurring at the work environment. The employer specifies harmful factors after recognizing sources of emission and work conditions, which influence levels of concentrations or intensity of the mentioned factors, or level of exposure to the mentioned factors. Tests and measurements of practically all physical and chemical factors, to which the worker at the work environment may be exposed, are carried out in thermal power plants which generate electric energy of fossil fuels (coal). The article covers identification of hazards at the thermal power plant and their analysis considering methods of their elimination.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2016, T. 4; 13-23
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetyczna ocena efektywności pracy elektrociepłowni gazowo-parowej z organicznym układem binarnym
Autorzy:
Nowak, W.
Powiązania:
https://bibliotekanauki.pl/articles/172827.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
spaliny odlotowe
turbina gazowa
elektrociepłownia parowa
exhaust gas
gas turbine
thermal-electric power station
Opis:
Przedstawiono analizę porównawczą efektywności wykorzystania spalin odlotowych turbiny gazowej do zasilania kilku różnych układów parowych z wykorzystaniem substancji organicznych jako czynników obiegowych. Przeanalizowano jednoobiegową elektrociepłownię parową, pracującą z wodą sieciową jako medium roboczym oraz jej sprzężenie cieplne za pomocą wymiennika typu skraplacz-parowacz z organicznym układem binarnym, w którym obieg górny zasilany jest wodą z elektrociepłowni, zaś w obiegach układu binarnego krążą odpowiednio dobrane czynniki organiczne. Opisano pracę oraz omówiono algorytm i wyniki obliczeń dla czynników organicznych, których zastosowanie pozwala na uzyskanie najlepszych efektów poprawy pracy elektrociepłowni gazowo-parowej współpracującej z układem binarnym, w odniesieniu do elektrociepłowni gazowo-parowej z jednoobiegowym układem parowym.
Źródło:
Archiwum Energetyki; 2011, 41, 1; 59-64
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognoza temperatury i wilgotności powietrza na wylocie parownika chłodziarki bezpośredniego działania
An air-temperature and air-humidity prognosis at an evaporator inlet of a direct-action refrigerator
Autorzy:
Nowak, B.
Łuczak, R.
Życzkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/165689.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
prognoza temperatury i wilgotności powietrza
chłodzenie powietrza
moc cieplna chłodnicy
air-temperature and air-humidity prognosis
air cooling
thermal power of cooler
Opis:
W artykule podano sposób określenia temperatury i wilgotności właściwej powietrza opuszczającego parownik chłodziarki bezpośredniego działania typu TS-300, pracującej w konkretnych warunkach cieplno-wilgotnościowych. W tym celu wykorzystano dane techniczne współpracującego z taką chłodnicą wentylatora lutniowego oraz równania modeli matematycznych opisujących pracę rozważanego systemu (Łuczak 2012, Nowak, Łuczak 2015, Nowak i in. 2016) i proces chłodzenia powietrza w parowniku (Filek, Nowak 1994). Uzyskane z rozwiązań przyjętych opisów matematycznych wyniki obliczeń numerycznych porównano z rezultatami pomiarów i określono istotność statystyczną uzyskanych odchyłek, oceniając tym samym praktyczną przydatność przyjętego modelu do oceny skuteczności pracy chłodziarki powietrza TS-300.
This paper presents methods of determination of temperature and specific humidity of air, leaving the direct-action refrigerator’s evaporator (TS-300) working in the particular hot-humidity conditions. For this, technical data of fan co-working with that cooler, mathematical equations describing operation of this system (Łuczak 2012, Nowak, Łuczak 2015, Nowak et al. 2016) as well as air-cooled process in the evaporator were used (Filek, Nowak 1994). The results obtained from mathematical equations were compared with the measured results and statistical significance of deviations were defined. For this reason, practical usability of the model for evaluation of the work effectiveness of the air refrigerator was examined.
Źródło:
Przegląd Górniczy; 2017, 73, 4; 56-61
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Moc cieplna wymienników górniczej sprężarkowej chłodziarki powietrza
Thermal power of exchangers in mine compression refrigerator of air
Autorzy:
Nowak, B.
Filek, K.
Powiązania:
https://bibliotekanauki.pl/articles/350086.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
chłodziarka sprężarkowa
moc wymienników ciepła
air conditioning of mine
air cooling
compression refrigerator
thermal power of heat exchanger
Opis:
Artykuł dotyczy górniczej sprężarkowej chłodziarki powietrza. Rozważono jej pracę zarówno z wewnętrznym regeneracyjnym wymiennikiem ciepła (dochładzaczem), jak i bez tego wymiennika. Podano równania, z których wyznaczyć można moce cieplne parownika, skraplacza i dochładzacza chłodziarki. Założono skupiony charakter wszystkich elementów chłodziarki (oprócz wymienionych, także sprężarki i zaworu rozprężnego). W przypadku chłodziarki z dochładzaczem otrzymano układ złożony z 12 równań algebraicznych, w którym niewiadomymi, oprócz mocy cieplnych trzech wspomnianych wymienników, są temperatura i wilgotność powietrza schłodzonego, temperatura wody za skraplaczem i temperatura czynnika chłodniczego w pięciu charakterystycznych punktach jego obiegu oraz stopień suchości czynnika na wlocie parownika. W przypadku chłodziarki bez dochładzacza układ składa się z dziewięciu równań o tych samych, co poprzednio, niewiadomych, z wyjątkiem trzech dotyczących dochładzacza.
This article applies to mine compression refrigerator of air. In this article, work of refrigerator with or without inner regenerative heat exchanger (subcooler) is considered. The equations are given, from which thermal powers of evaporator, condenser and subcooler of refrigerator are determined. Focused character of all elements of refrigerator is assumed (expect specified, compressor and expansion valve also). For refrigerator with subcooler, system compound with 12 algebraic equations is received, in which unknowns are: temperature and humidity of cooled air, temperature of water after the condenser and temperature of refrigerant in five characteristic points of its circulation and ariolity degree of refrigerant of evaporator's inlet. For refrigerator without subcooler, the system is composed of 9 equations with the same as before unknowns, with the exception of 3 equations refer to subcooler.
Źródło:
Górnictwo i Geoinżynieria; 2009, 33, 3; 79-91
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrownia Jaworzno I (1898-1998)
Jaworzno I power plant (1898-1998)
Autorzy:
Kwiatkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1197546.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
Elektrownia Jaworzno I
Historia elektrowni
Elektrownia cieplna
Elektrownia kopalniana
Jaworznickie Komunalne Kopalnie Węgla
Jaworzno I Power Plant
History of Power Plant
Thermal Power Plant
Coal mine-owned Power
Plant Jaworzno Municipal Coal Mines
Opis:
Power plant, commissioned in 1898 for the needs of Jaworzno hard-coal mines, was one of the first power plants operating in the former Galicia. Due to the characteristics of Jaworzno coal beds, the power plant was mainly used for the water removal in the mines. Poland’s restored independence encouraged local authorities to buy the coal mine from the Austrians and set up a company called Jaworzno Municipal Coal Mines Ltd. in Krakow. The power plant gradually enlarged its area of electrical energy supply. The breakthrough moment was the order of 6 MW from the Municipality of Krakow. 60 kV distribution line was constructed for this purpose to connect Jaworzno and Krakow power plants. During the WWII, the Nazi occupants commenced further development of the power plant. The end of WWII marked the initiated construction of reinforced concrete boiler support structure. The entire modernization was completed in 1959 with the total installed capacity amounting to 158 MW. Further works were carried out so as to improve the electrical energy generation efficiency. Development of the city of Jaworzno impacted on the power plant’s restructuration into combined heat and power plant. The CHP-plant was permanently shut down after 100 years of operation.
Elektrownia uruchomiona w 1898 roku na potrzeby jaworznickich kopalń węgla kamiennego, była jedną z pierwszych elektrowni Galicji. Z racji właściwości złóż węgla jaworznickiego, służyła głównie do odwadniania kopalń. Już w 1910 roku uruchomiono tam pierwszy turbozespół. Mechanizacja robót górniczych zwiększała ilość posiadanych turbozespołów. Odzyskanie przez Polskę niepodległości zachęciło lokalne władze do wykupienia z rąk austriackich kopalni i utworzenia spółki: „Jaworznickie Komunalne Kopalnie Węgla SA w Krakowie”, właścicielami jej były miasta Kraków i Lwów oraz konsorcjum polskich banków. Elektrownia kopalniana stopniowo rozszerzała obszar swego zasilania. Momentem znacząco wpływającym na rozwój elektrowni było zamówienie przez Kraków 6 MW mocy. Do jej przesyłu wybudowano linię 60 kV łączącą elektrownię jaworznicką z elektrownią krakowską i rozbudowano elektrownię. W czasie II wojny światowej okupanci rozpoczęli kolejną rozbudowę elektrowni. Wyzwolenie zastało rozpoczętą żelbetową konstrukcję nośną kotła. Kontynuowano rozbudowę elektrowni. Oparto ją na dostawach zagranicznych urządzeń. Dopiero w 1952 roku uruchomiono pierwszą turbinę. Rozbudowę zakończono w 1959 roku uzyskując prawie 158 MW mocy. Dalsze modernizacje były prowadzone w celu poprawy sprawności wytwarzania energii. Rozwój Jaworzna wymusił przekształcenie elektrowni w elektrociepłownię. Po 100 latach istnienia została wyłączona.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 4, 120; 217-224
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The possibilities of meeting energy demands in system thermal power plants by using local solid biomass
Możliwość zaspokojenia potrzeb energetycznych w ciepłownicach systemowych przez wykorzystanie lokalnej biomasy stałej
Autorzy:
Jasiulewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1790575.pdf
Data publikacji:
2019
Wydawca:
The Polish Association of Agricultural and Agribusiness Economists
Tematy:
energy demand in a thermal power plant
local biomass resources
meeting energy demands
potrzeby energetyczne ciepłowni
zasoby lokalnej biomasy stałej
zaspokojenie potrzeb energetycznych
Opis:
What is of crucial importance in local conditions as concerns the heat power industry is the use of local biomass, especially waste biomass, as an energy raw material in the existing system of thermal power plants. The purpose of the present study is to assess the possibility of replacing hard coal as an energy raw material with solid biomass. Solid biomass is constituted by: surpluses of cereal straw and rape straw, as well as hay from unused meadows, from the upkeep of roadside trees and from energy crop plantations. The research was conducted on the example of thermal power plants associated in the “Together Warmer” Cluster. This cluster is formed by 10 thermal power plants in small towns in the Warmińsko-Mazurskie Province and the city of Biała Podlaska (Lubelskie Province). All of these are located in north-east Poland. Considering the high transport costs of biomass, a biomass technical potential was accepted within a radius of 30 km from the thermal power plant. The solid biomass potential for each of the ten thermal power plants demonstrates that most of the thermal power plants from the Cluster under examination are able to meet their energy needs with solid biomass from the nearest neighbourhood (replace hard coal). However, when taking a decision on replacing hard coal with local biomass, it is necessary to adequately handle logistics and replace boilers in thermal power plants with special boilers for the combustion of solid biomass.
W warunkach lokalnych w zakresie energetyki cieplnej istotną sprawą jest wykorzystanie lokalnej biomasy, zwłaszcza odpadowej, jako surowca energetycznego w istniejących ciepłowniach systemowych. Celem opracowania jest oszacowanie możliwości zastąpienia węgla kamiennego, jako surowca energetycznego biomasą stałą. Biomasę stałą tworzą nadwyżki słomy zbóż oraz rzepaku, a także siano z niewykorzystanych łąk, pielęgnacji drzew przydrożnych oraz z plantacji upraw energetycznych. Badania przeprowadzono na przykładzie zrzeszonych ciepłowni w Klastrze „Razem Cieplej”. Klaster ten tworzy 10 ciepłowni w niedużych miastach województwa warmińsko-mazurskiego oraz w mieście Biała Podlaska (w województwie lubelskim). Całość zlokalizowana jest w północno-wschodniej Polsce. Ze względu na wysokie koszty transportu biomasy uwzględniono potencjał techniczny biomasy z obszaru w promieniu 30 km od ciepłowni. Oszacowany potencjał biomasy stałej dla każdej z 10 ciepłowni wskazuje, że większość ciepłowni lokalnych badanego klastra jest w stanie zaspokoić swoje potrzeby energetyczne (zastąpić węgiel kamienny) biomasą stałą z najbliższej okolicy. Przy podjęciu decyzji o zastąpieniu węgla lokalną biomasą – konieczne jest odpowiednie przygotowanie logistyki, a także wymiana kotłów w ciepłowniach na specjalne kotły do spalania biomasy stałej.
Źródło:
Annals of The Polish Association of Agricultural and Agribusiness Economists; 2019, 21, 3; 164-172
2657-781X
2657-7828
Pojawia się w:
Annals of The Polish Association of Agricultural and Agribusiness Economists
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of the heat-absorbing surface of an air-cooled solar collector on its thermal and mechanical properties
Autorzy:
Zhelykh, Vasyl
Ulewicz, Małgorzata
Kozak, Krystyna
Savchenko, Olena
Kasynets, Mariana
Powiązania:
https://bibliotekanauki.pl/articles/88616.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
solar air collector
heat-absorbing plate
flow turbulators
thermal power
air channel
powietrzny kolektor słoneczny
płyta pochłaniająca ciepło
turbulatory przepływowe
energetyka cieplna
kanał powietrzny
Opis:
This paper presents the analysis of existing forms of heat absorbing surfaces of air solar collectors, which gained the greatest popularity in the world. The obtained data allowed to conclude that there is a need for the development of solar collectors with air as a coolant with an improved form of heat absorber, which will reduce the operational and capital costs of solar systems and allow the efficient use of such structures in a moderate climate without additional mechanisms for the transfer of coolant. The use of computer simulation helped to compare the thermal characteristics of air-borne solar collectors of a different design. The substantiation of the expediency of installing as a heat absorber of flow turbulators in the form of a screw has been fulfilled, as well as the height of the air channel of the solar collector has been determined, in which the maximum heating of the transfer medium is observed. In addition, the loss of pressure in the air channel of the solar collector with flow turbulators was determined and the comparison of the obtained data with the values of pressure losses in the air collector of the matrix type and the air collector with V-shaped ribs was made.
Źródło:
System Safety : Human - Technical Facility - Environment; 2019, 1, 1; 481-489
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza emisji zanieczyszczeń w wyniku wytwarzania energii cieplnej
Analysis of Emission of Pollution Resulting from Thermal Energy Production
Autorzy:
Noch, T.
Mikołajczewska, W.
Wesołowska, A.
Friedberg, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813745.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
energetyka cieplna
środowisko
spalanie
emisja zanieczyszczeń
olej opałowy
kotłownia
moc
pompa ciepła
OZE
ochrona środowiska
thermal power engineering
environment
emission of pollution
heating oil
boiler
power
heat pump
renewable energy
environment protection
Opis:
W opracowaniu przedmiotem badań jest wytwarzanie energii cieplnej. W wyniku tego zjawiska następuje emisja zanieczyszczeń do atmosfery. Wielkość emisji uzależniona jest od rodzaju i ilości spalanego paliwa. W pracy przedstawiono parametry techniczno-technologiczne urządzeń energetyki cieplnej wykorzystywane w procesie badawczym. W obiekcie eksploatowane są dwa kotły Paromat-Simplex z palnikami Weishaupt L5T D oraz jeden kocioł Paromat ER ND z palnikiem Weishaupt L1Z-B. W pracy dokonano obliczeń wielkości i parametrów emisji. Przeprowadzono badania i obliczenia stężeń emitowanych zanieczyszczeń dla kotłowni olejowej wodno-parowej, eksploatowanej przez obiekt zlokalizowany w Gdańsku Stogach. Badania dotyczą również wykorzystania źródeł energii odnawialnej. W wyniku przeprowadzonych badań porównawczych z zastosowaniem kotła Pilewang Gizex – PM stwierdzono, że oddziaływanie spalania słomy na stan czystości powietrza atmosferycznego jest mniej negatywne niż spalania węgla. Bilans emisji dwutlenku węgla podczas spalania biomasy jest zerowy, gdyż wytworzona jego ilość jest równoważna ilości CO2 pobranej przez roślinę podczas jej wzrostu. Analizą objęto również współpracę kotłowni z zespołem pomp ciepła. System hybrydowy uwzględnia różną moc zainstalowaną w pompach ciepła w granicach Qpc = 13,5-67,5 kW. Moc szczytowa kotłów jest równa Qhybr. = 262,5 kW. Zastosowanie pomp ciepła zmniejszy emisję dwutlenku węgla, odpowiednio dla QPC = 67,5 kW o ∆BCO2 = 33 Mg/a oraz dla QPC = 13,5 kW o ∆BCO2 = 6,6 Mg/a. Z uwagi na to, że badany obiekt zlokalizowany jest na terenie Nadmorskiego Parku Krajobrazowego, wskazane jest możliwie największe ograniczenie emisji zanieczyszczeń z kotłowni (dwutlenku węgla, tlenków siarki, tlenków azotu). Wykorzystanie odnawialnych źródeł energii przez lokalną energetykę cieplną jest korzystne dla ochrony środowiska.
The research is related to thermal energy production and related air pollutions. As a result of this process, emission of pollution to the atmosphere occurs. The effect of pollution depends on the sort and amount of combusted fuel. Technical and technological parameters of thermal energy installations, which have been used in the research process, have been presented. In the building there are two Paromat-Simplex boilers with Weishaupt L5T D burners. In addition to this, a boiler Paromat ER ND with Weishaupt L1Z-B burner is installed. The boilers characteristics are discussed. The influence of thermal energy sources on the environment has been taken into account. Calculations of the volume and parameters of emission have been conducted. The research also concerns the use of renewable energy. As a result of the comparative research with the application of Pilewang Gizex – PM boiler it was found that the influence of straw combustion on the quality of air is less negative than coal combustion. Carbon dioxide emission of biomass combustion is neglected because its amount equals the amount of CO2 absorbed by a plant during its growth. The analysis includes also the hybrid system of a boiler with a set of heat pumps in the power range Qpc = 13,5-67,5 kW. Maximum power of boilers is Qhybr. = 262,5 kW. The application of heat pumps reduces carbon dioxide emission: for QPC = 67,5 kW reduction is ∆BCO2 = 33 Mg/a and for QPC = 13,5 kW it correspond to ∆BCO2 = 6,6 Mg/a. Due to the fact that the object being the subject of the research is located in the Coastal Landscape Park (pol. Nadmorski Park Krajobrazowy) it is advisable to significantly reduce emission of pollution from boilers (carbon dioxide, sulfur oxides, nitrogen oxides). The application of renewable sources of energy by local thermal power engineering is favorable for the protection of the environment.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1181-1198
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetyka jądrowa – konieczność, a nie zagrożenie
Nuclear power – a necessity, not a threat
Autorzy:
Domański, Roman
Powiązania:
https://bibliotekanauki.pl/articles/2176255.pdf
Data publikacji:
2022
Wydawca:
Mazowieckie Biuro Planowania Regionalnego w Warszawie
Tematy:
promieniowanie
rozpad promieniotwórczy
reaktor jądrowy
chłodziwo
moderator
moc cieplna
moc elektryczna
awaria
obieg parowy
paliwo jądrowe
sprawność
radiation
radioactive decay
nuclear reactor
coolant
thermal power
electrical power
failure
steam cycle
nuclear fuel
efficiency
Opis:
W pracy przedstawiono w skrócie potrzeby energetyczne świata, podział zużycia energii pierwotnej z punku widzenia paliw oraz 3 podstawowe scenariusze rozwoju świata prezentowane przez Międzynarodową Agencję Energii. Omówiono podstawowe procesy dotyczące wytwarzania energii jądrowej i jej konwersji na energię wewnętrzną. Przedstawiono najważniejsze typy reaktorów jądrowych podając ich podstawowe parametry pracy. W posumowaniu przedstawiono zasadnicze wnioski.
The work briefly outlines the world's energy needs, the division of primary energy consumption from a fuel perspective and the three basic world development scenarios presented by the International Energy Agency. The basic processes of nuclear power production and its conversion into internal energy are discussed. The most important types of nuclear reactors are presented with their basic operating parameters. The basic conclusions are presented in the summary.
Źródło:
MAZOWSZE Studia Regionalne; 2022, 42; 25-60
1689-4774
Pojawia się w:
MAZOWSZE Studia Regionalne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the Thermal Power of Groundwater Intakes in The Kielce District
Autorzy:
Nartowska, Edyta
Budzianowski, Dominik
Styś-Maniara, Marta
Powiązania:
https://bibliotekanauki.pl/articles/27314854.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
low-temperature geothermal energy
RES
thermal power
energy efficiency index
groundwater intake
heat pump
geotermia niskotemperaturowa
OZE
moc cieplna
wskaźnik efektywności energetycznej
ujęcie wód podziemnych
pompa ciepła
Opis:
The purpose of the article was to estimate the thermal power of groundwater intakes of the Kielce district within the sheets of hydrogeological maps with the serial numbers MHP 813-817, MHP 850-851, and to indicate in this area prospective areas for the development of low-temperature geothermal energy supported by water/water heat pumps. Based on the calculations on the basis of 147 groundwater intakes, it was determined that the estimated values of thermal power resources are in the range of 3.47 kW to 5757.34 kW. The created map of the low-temperature geothermal potential for groundwater intakes indicates the towns of Bodzentyn, Morawica and the villages of Piekoszów, Wolica and the area around the village of Górno as prospective areas.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 25--49
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal power of the TS-300B refrigerator in the aspects of statistical research
Moc cieplna chłodziarki TS-300B w aspekcie badań statystycznych
Autorzy:
Nowak, B.
Łuczak, R.
Powiązania:
https://bibliotekanauki.pl/articles/219985.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
local cooling systems
direct action refrigerator
air conditioning in mines
evaporator thermal power
multiple regression
lokalne systemy chłodnicze
chłodziarka bezpośredniego działania
klimatyzacja kopalń
moc cieplna parownika
regresja wieloraka
Opis:
The article discusses the improvement of thermal working conditions in underground mine workings, using local refrigeration systems. It considers the efficiency of air cooling with direct action air compression refrigerator of the TS-300B type. As a result of a failure to meet the required operating conditions of the aforementioned air cooling system, frequently there are discrepancies between the predicted (and thus the expected) effects of its work and the reality. Therefore, to improve the operating efficiency of this system, in terms of effective use of the evaporator cooling capacity, quality criteria were developed, which are easy in practical application. They were obtained in the form of statistical models, describing the effect of independent variables, i.e. the parameters of the inlet air to the evaporator (temperature, humidity and volumetric flow rate), as well as the parameters of the water cooling the condenser (temperature and volumetric flow rate), on the thermal power of air cooler, treated as the dependent variable. Statistical equations describing the performance of the analyzed air cooling system were determined, based on the linear and nonlinear multiple regression. The obtained functions were modified by changing the values of the coefficients in the case of linear regression, and of the coefficients and exponents in the case of non-linear regression, with the independent variables. As a result, functions were obtained, which were more convenient in practical applications. Using classical statistics methods, the quality of fitting the regression function to the experimental data was evaluated. Also, the values of the evaporator thermal power of the refrigerator, which were obtained on the basis of the measured air parameters, were compared with the calculated ones, by using the obtained regression functions. These statistical models were built on the basis of the results of measurements in different operating conditions of the TS-300B refrigerator, both on the test stand in the manufacturer’s laboratory and in the workings of underground mines. The evaluation of the measurement data distributions, as well as an analysis of the basic descriptive statistics of the mentioned variables were carried out, determining their measures of central tendency, location, dispersion and asymmetry.
Artykuł dotyczy poprawy cieplnych warunków pracy w wyrobiskach górniczych kopalń podziemnych stosujących lokalne systemy chłodnicze. Rozważa się w nim skuteczność schładzania powietrza chłodziarką sprężarkową bezpośredniego działania typu TS-300B. Bardzo często, w wyniku niedotrzymania wymaganych warunków pracy wymienionego systemu chłodzenia powietrza, występują rozbieżności między prognozowanymi, a więc oczekiwanymi efektami jego pracy a rzeczywistością. Dlatego, dla poprawy skuteczności pracy tego systemu, opracowano, pod kątem efektywnego wykorzystania mocy chłodniczej parownika takiej chłodziarki, łatwe w zastosowaniu praktycznym kryteria jakości. Otrzymano je w postaci modeli statystycznych określających wpływ zmiennych niezależnych, tj. parametrów powietrza wlotowego do parownika (temperatury, wilgotności i wydatku objętościowego) oraz parametrów wody chłodzącej skraplacz (temperatury i wydatku objętościowego) na moc cieplną chłodnicy powietrza traktowaną jako zmienna zależna. Równania statystyczne opisujące pracę rozważanego systemu chłodzenia powietrza wyznaczono na podstawie wielorakiej regresji liniowej i nieliniowej. Utworzone funkcje zmodyfikowano poprzez zmianę wartości współczynników w przypadku regresji liniowej oraz współczynników i wykładników w przypadku regresji nieliniowej, przy zmiennych niezależnych. Otrzymano w ten sposób funkcje dogodniejsze w praktycznych wykorzystaniach. Korzystając z metod statystyki klasycznej oceniono jakość dopasowania funkcji regresji do danych eksperymentalnych. Porównano także wartości mocy cieplnych parownika chłodziarki otrzymane na podstawie pomierzonych parametrów powietrza z obliczonymi przy wykorzystaniu utworzonych funkcji regresji. Powyższe modele statystyczne utworzono na podstawie wyników pomiarów w różnych warunków pracy chłodziarki TS-300B, zarówno na stanowisku badawczym w laboratorium jej producenta jak i w wyrobiskach górniczych kopalń podziemnych. Dokonano oceny rozkładów danych pomiarowych oraz przeprowadzono analizę podstawowych statystyk opisowych wymienionych zmiennych określając ich miary przeciętne, pozycyjne, rozrzutu i asymetrii.
Źródło:
Archives of Mining Sciences; 2015, 60, 3; 715-728
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Genetic algorithm tuned IP controller for Load Frequency Control of interconnected power systems with HVDC links
Autorzy:
Selvakumaran, S.
Rajasekaran, V.
Karthigaivel, R.
Powiązania:
https://bibliotekanauki.pl/articles/140655.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
genetic algorithm
Load Frequency Control
IP controller
AC-DC tie-lines
interconnected thermal non-reheat power systems
Opis:
A new design of decentralized Load Frequency Controller for interconnected thermal non-reheat power systems with AC-DC parallel tie-lines based on Genetic Algorithm (GA) tuned Integral and Proportional (IP) controller is proposed in this paper. A HVDC link is connected in parallel with an existing AC tie-line to stabilize the frequency oscillations of the AC tie-line system. Any optimum controller selected for load frequency control of interconnected power systems should not only stabilize the power system but also reduce the system frequency and tie line power oscillations and settling time of the output responses. In practice Load Frequency Control (LFC) systems use simple Proportional Integral (PI) or Integral (I) controller. The controller parameters are usually tuned based on classical or trial-and-error approaches. But they are incapable of obtaining good dynamic performance for various load change scenarios in multi-area power system. For this reason, in this paper GA tuned IP controller is used. A two area interconnected thermal non-reheat power system is considered to demonstrate the validity of the proposed controller. The simulation results show that the proposed controller provides better dynamic responses with minimal frequency and tie-line power deviations, quick settling time and guarantees closed-loop stability margin.
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 161-175
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal properties of nanoliquids in the aspects of their used in the insulation system of high voltage power transformer
Autorzy:
Dombek, G.
Nadolny, Z.
Przybyłek, P
Powiązania:
https://bibliotekanauki.pl/articles/97610.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
nanoliquids
high voltage power transformers
thermal properties
Opis:
The article presents information concerning the electrical and thermal properties of nanoliquids in the context of their use in the insulating system of high voltage power transformers. It consists of six chapters. The first chapter is an introduction. The second chapter describes properties of the modern insulating nanoliquids created on the basis of mineral oil and nanoparticles. The third chapter is devoted to the measurement systems to the measure of the viscosity, thermal conductivity and density. The fourth chapter presents the methods of preparation of nanoliquids. In the fifth chapter the viscosity, thermal conductivity and density of mineral oil and nanoliquids were compared. Article ends with a summary.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 217-226
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ispolzovanie teplovyh metodov v diagnostike ènergetičeskogo oborudovania rybolovnyh sudov
The using of thermal method in diagnostic of marine plant operation of fishing fleet vessel
Autorzy:
Klyus, O.
Behrendt, C.
Rajewski, P.
Szczepanek, M.
Bezyukov, O.
Kordakov, A.
Powiązania:
https://bibliotekanauki.pl/articles/359249.pdf
Data publikacji:
2013
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
diagnostic
thermal method
maritime power plant operation
Opis:
The article presented non destruction method and results of using thermal method in diagnostic of marine plant operation of fishing fleet vessel.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2013, 35 (107); 76-85
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison between thermal simulation results generated by PLECS software and laboratory measurements
Autorzy:
Mysiński, Wojciech
Sysło, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/377458.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
thermal simulation
PLECS
buck converter
thermal time constant
IGBT
diode
power losses
Opis:
This article deals with the subject of simulation of power losses and thermal processes occurring in semiconductors, as illustrated by an example of a DC/DC buck converter. The simulations were performed in PLECS software. The results obtained from the program were compared with measurement results of a laboratory converter model. The physical model is based on the same components as assumed in the simulation. Similarly, the parameters of the transistor control signal were the same. During operation of the converter, the temperature changes were analyzed using a K-type thermocouple. Based on the obtained results of the temperature measurement in the steady state of the converter operation, the correctness of the simulation carried out in the PLECS program was verified and confirmed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 99; 29-40
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Izolacja termiczna w zespołach napędowych rakiet po długoletnim składowaniu
Thermal isolation in rocket motor units after long term storing
Autorzy:
Studencki, M.
Powiązania:
https://bibliotekanauki.pl/articles/235543.pdf
Data publikacji:
2008
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
izolacja termiczna
zespoły napędowe
thermal insulation
power plants
Opis:
W artykule omówiono celowość stosowania izolacji termicznej w zespołach napędowych rakiet na paliwo stałe. Na podstawie własnych badań, przedstawiono budowę i technologię wykonania warstwy termoizolacyjnej w zespołach napędowych rakiet przeciwlotniczych „OSA”. W formie dokumentacji fotograficznej, zaprezentowano jedną z metod oceny stanu technicznego tej warstwy z wykorzystaniem aparatury endoskopowej. Przedstawiono wyniki badań własnych mających na celu ustalenie przyczyn spalenia powłoki lakierniczej na zewnętrznej powierzchni zespołu napędowego rakiety „OSA”. Wskazano na konieczność chronienia powierzchni komory spalania przed mechanicznymi uderzeniami i większymi statycznymi naciskami z zewnątrz.
The expediency of using thermal isolation in rocket solid propellant motor units is presented in the paper. The design and technology for getting a thermo-isolating layer in motor units of antiaircraft missiles OSA is provided on the base of own research work. Technical evaluation of this layer was carried out by the endoscopic instrument and some results presented in the pictures included. Some results of own research work are presented to show the reasons for burning the paint coating on the external surface of OSA motor. It was pointed that there is an expediency to protect the surface of the burning chamber against mechanical hits and greater static stresses from outside.
Źródło:
Problemy Techniki Uzbrojenia; 2008, R. 37, z. 106; 75-88
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and verification of the chip thermal model: the assessment of a power modules resistance to high current peaks
Autorzy:
Pavlásek, P.
Mrázik, M.
Pavelek, M.
Dobrucký, B.
Powiązania:
https://bibliotekanauki.pl/articles/377849.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
power modules
thermal model
simulation
finite element method
Opis:
The paper is focused on creating a thermal model which provides information about the thermal conditions in the semiconductor devices. Increasing the current density and pressure on prices make the optimization of thermal systems an important part in the design process. Simulation analysis has become with development of computer technology an excellent equipment to achieve it. In creating the model, we take account of material and geometric parameters of bonded chips. By the simulation we obtain the necessary information about the components and thermal stresses, these results can be applied in the device design procedure and technology of production. Resistance to bonded diodes is determined by chip parameters and bonding parameters such as the number of bundles, their spacing, and material. Resistance in practice is determined by experimentally measuring IFSM, a peak permeable, unrepeatable current. Also, in the work we analysed voltage-current VA characteristics of power diodes such as threshold voltage, also the closing voltage we tested functionality and we observe changes in the behaviour of the component and, last but not least, the characteristics of thermal resistance and thermal impedance that served as elements for the construction of an equivalent model. In the next part of the paper, in the context of the works, the methods of bindings of PCB components are currently being extended and used in current technological processes and we also concentrate on the dimensional parameters of the modules used to create an equivalent electrical circuit. The presented assembled simplified model respects the chip size, number of bonding wires, and their layout on the chip. For the concept of nine bonds, we had two types of placement from a variety of bonds, so we also respected this factor in the design of the model. As an example, there is a diode module investigated (SKEE SEMIPACK® 2, 1600V/174A).
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 95; 57-65
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techno-Economic Assessment of Concentrating Solar Power and Wind Hybridization in Jordan
Autorzy:
Ayadi, O.
Alsalhen, I. A.
Powiązania:
https://bibliotekanauki.pl/articles/124277.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
concentrated solar power
wind
thermal energy storage
hybridization
Opis:
The variable renewable wind and solar resources have experienced a significant growth on its rate of deployment as a clean and competitive alternative for conventional power sources in Jordan. However, the variability of these sources have brought many technical challenges to grids. This paper presents a hybrid system that provides a firma capacity and improves dispatchability with an interesting financial perspective. This hybrid system includes a wind farm and a concentrated solar power plant with thermal energy storage. The performance analysis was conducted in terms of final yield and capacity factor, while the economic analysis investigated the levelized cost of electricity LCOE. The hybrid plant was simulated and optimized using TRNSYS 17 energy simulation software, minimizing the LCOE and considering a capacity factor higher than 65% as a constraint. Solar multiple and storage size were considered as decision variables. A strong complementarity between wind and direct normal solar radiation was observed in the selected location in Jordan, which emphasizes the attractiveness of the selected hybrid system. The optimal configuration of the CSP-wind hybrid system was obtained with a solar field of a 2.6 solar multiple and a 5 hours energy storage. The achieved capacity factor was 94%, and the LCOE is lower than those resulted for standalone CSP plants.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 16-23
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method Of Calculating Thermal Diffusivity And Conductivity For Irregularly Shaped Specimens In Laser Flash Analysis
Autorzy:
Szałapak, J.
Kiełbasiński, K.
Krzemiński, J.
Młożniak, A.
Zwierkowska, E.
Jakubowska, M.
Pawłowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/220433.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal diffusivity
LFA
LTJT joints
high power electronics
Opis:
The Low Temperature Joining Technique (LTJT) using silver compounds enables to significantly increase the thermal conductivity between joined elements, which is much higher than for soldered joints. However, it also makes difficult to measure the thermal conductivity of the joint. The Laser Flash Analysis (LFA) is a non-intrusive method of measuring the temperature rise of one surface of a specimen after excitation with a laser pulse of its other surface. The main limitation of the LFA method is its standard computer software, which assumes the dimensions of a bonded component to be similar to those of the substrate, because it uses the standard Parker’s formula dedicated for one-dimensional heat flow. In the paper a special design of measured specimen was proposed, consisting of two copper plates of different size joined with the sintered silver layer. It was shown that heat properties of these specimens can also be measured after modifying the LFA method. The authors adapted these specimens by masking the false heat signal sourced from the uncovered plate area. Another adaptation was introducing a correcting factor of the heat travel distance, which was calculated with heat-flow simulations and placed into the Parker’s formula. The heat-flow simulated data were compared with the real LFA measurement results, which enabled estimation of the joint properties, e.g. its porosity.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 521-530
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected problems of determining an efficient operation standard in contemporary heat-and-flow diagnostics
Autorzy:
Głuch, J.
Powiązania:
https://bibliotekanauki.pl/articles/259296.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
steam turbines
operation of turbines
power units
thermal measurements
thermal diagnostics
diagnostic relations
Opis:
In this paper are specified causes of ambiguities and difficulties in determining an efficient operation standard for land and marine turbine power plants. Two of them, namely: lowering values of working media inlet parameters and changes in configuration of connections between component devices of thermal cycles, have been analyzed. As a remedy for resulting difficulties a thermal cycle computational model of modular structure has been proposed. As showed, the tuning of the computational model with respect to correct measurements by elaborating individual corrections for calculation coefficients of computational methods used for particular devices ensures good accuracy of determination of unserviceability symptoms in these conditions. Introduction to the modular computational model – of control modules making use of valve opening indicators in DCS system ensures good accuracy also in the case of changes in structure of complex power object.
Źródło:
Polish Maritime Research; 2009, S 1; 22-27
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal efficiency and hydraulic performance evaluation on Ag–Al2O3 and SiC–Al2O3 hybrid nanofluid for circular jet impingement
Autorzy:
Datta, Abanti
Halder, Pabitra
Powiązania:
https://bibliotekanauki.pl/articles/1845498.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hybrid nanofluid
thermal performance factor
pumping power
merit number
Opis:
Hybrid nanofluids is obtained by dispersing more than one nanoparticle into a base fluid. The work is concerned with a detailed numerical investigation of the thermal efficiency and hydraulic performance of hybrid nanofluids for circular jet impinges on a round plate. For this paper, a metal (Ag), a metal oxides (Al2O3) and a metal carbides (SiC) nanoparticle and their water based hybrid nanofluids are considered to analyse numerically with varying significant dimensionless parameters, i.e., the jet-to-plate spacing ratio, Reynolds number and volume fraction of nanoparticles. The results demonstrated that the efficiency of heat transfer of all nanofluids is increased by the addition of nanoparticle to the dispersed in water at constant Reynolds number. Moreover, the results illustrate that heat transfer efficacy and pumping power penalty both increased as jet-to-plate spacing ratio reduced. The jet-to-plate spacing ratio equal to 4 is the best as the percentage enhance heat transfer is maximum in this situation. Since both the heat transfer effect and pumping penalty increase using hybrid nanofluids, thermal performance factor increases or decreases depends on nanoparticles of nanofluids. It is evident that the analysis of these hybrid nanofluids will consider both the increase in heat efficiency and the pumping capacity. The best flow behaviour is achieved for SiC–Al2O3 hybrid nanofluids. New merit number is introduced for additional clarification.
Źródło:
Archives of Thermodynamics; 2021, 42, 1; 163-182
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of power losses in a high-frequency planar transformer using a thermal camera
Autorzy:
Barlik, R.
Nowak, M.
Grzejszczak, P.
Zdanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/140759.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power losses estimation
thermal camera
thermal calibration
planar transformer
Dowell’s and Steinmetz’s equations
Opis:
This paper presents the implementation of a thermal camera for the quantitative estimation of power losses in a high frequency planar transformer (100 kHz/ 5600 VA). The methodology is based on the observation of the transient temperature rise and determination of the power losses by means of curves representing the derivative of temperature as a function of power losses dissipated in the transformer. First, the thermal calibration characteristics had to be obtained from a simple experiment, where power losses are generated by DC current in the ferrite core and windings. Next, experimental investigations focused on the determination of the transformer power losses for a short circuit and no load, with a resistive load and with the rectifier as a load were carried out. Finally, to verify the obtained results, analytical calculations based on Dowell’s and modified Steinmetz’s equations were additionally made, which showed a good convergence. The proposed method is easy to implement and can be used as an alternative to the calorimetric method which is time-consuming and requires a complicated measurement setup.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 613-627
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal stresses due to frictional heating with time-dependent specific power of friction
Autorzy:
Topczewska, K.
Powiązania:
https://bibliotekanauki.pl/articles/386412.pdf
Data publikacji:
2017
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
frictional heating
temperature
thermal stresses
time-dependent power of friction
Opis:
In this paper influence of temporal profile of the specific friction power (i.e. the product of the coefficient of friction, sliding velocity and contact pressure) on thermal stresses in a friction element during braking was investigated. Spatio-temporal distributions of thermal stresses were analytically determined for a subsurface layer of the friction element, based on the model of thermal bending of a thick plate with unfixed edges (Timoshenko and Goodier, 1970). To conduct calculations, the fields of dimensionless temperature were used. These fields were received in the article (Topczewska, 2017) as solutions to a one-dimensional boundary-value problem of heat conduction for a semi-space heated on its outer surface by fictional heat flux with three, different time profiles of the friction power.
Źródło:
Acta Mechanica et Automatica; 2017, 11, 4; 280-284
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical model for investigation of the effect of friction power on thermal stresses in friction elements of brakes
Autorzy:
Topczewska, K.
Powiązania:
https://bibliotekanauki.pl/articles/281308.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
frictional heating
temperature
specific power of friction
braking
thermal stresses
Opis:
The influence of the change with time of friction power on thermal stresses in a friction element of a brake system is investigated. For this purpose, a list of ten different temporal profiles of specific friction power is used, which has been experimentally established for a single braking process. The corresponding profiles of transient temperature fields in the considered element are applied as input parameters to find quasi-static thermal stresses. Numerical analysis concerned with spatio-temporal distributions of the stresses and their evolutions on the heated surface is presented.
Źródło:
Journal of Theoretical and Applied Mechanics; 2018, 56, 4; 1017-1027
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A qualitative study of mixing a fluid inside a mechanical mixer with the effect of thermal buoyancy
Autorzy:
Hassouni, Souad
Laidoudi, Houssem
Makinde, Oluwole Daniel
Bouzit, Mohamed
Boumediene, Haddou
Powiązania:
https://bibliotekanauki.pl/articles/2204073.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mechanical agitation
mixing process
heat transfer
thermal buoyancy
power number
Opis:
This paper is concerned with the rotational motion of the impeller and the thermal buoyancy within a mechanical mixer. The task was investigated numerically using the ANSYS-CFX simulator. The programmer is based on the finite volume method to solve the differential equations of fluid motion and heat transfer. The impeller has hot surfaces while the vessel has cold walls. The rotational movement of the impeller was controlled by the Reynolds number, while the intensity of the thermal buoyancy effect was controlled by the Richardson number. The equations were solved for a steady flow. After analyzing the results of this research, we were able to conclude that there is no effect of the values of Richardson number on the power number. Also, with the presence of the thermal buoyancy effect, the quality of the fluid mixing becomes more important. The increasing Richardson number increases the value of the Nusselt number of the impeller.
Źródło:
Archives of Thermodynamics; 2023, 44, 1; 105--119
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Characterization of High-Frequency Flyback Power Transformer
Autorzy:
Kasikowski, R.
Gołaszewski, J.
Więcek, B.
Farrer, M.
Powiązania:
https://bibliotekanauki.pl/articles/114581.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IR thermography
power losses
H-F flyback transformer
thermal impedance
Opis:
This paper presents preliminary thermographic measurements and a simple thermal analysis of power losses in high-frequency (H-F) transformers used in AC-DC power converters. The analysis is based on complex thermal impedance and time constant distribution. The main aim of this research was to consider quantitatively the contribution of different power losses in the H-F transformer, including fringing flux effect.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 237-241
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal calculation for distance protection enhancement
Autorzy:
Staszewski, Ł
Rebizant, W
Powiązania:
https://bibliotekanauki.pl/articles/410608.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
distance protection
power swing
third zone
Opis:
Worldwide analysis of recent wide area cascading failures has shown that very often their main cause was the mal-operation of the distance protection relay third zone. The load encroachment and power swing phenomena are the two dire problems to solve when dealing with the third zone of distance protection. The vast number of blackouts could have been avoided or the consequences lowered if the distance relay had not operated due to impedance encroachment while there was no risk of further, continuous operation. This paper proposes a way to improve operation of the distance protection relay by introducing a new blocking algorithm that uses the Dynamic Thermal Line Rating (DTLR) to restrain relay from tripping when conditions in electrical power system allow for it.
Źródło:
Present Problems of Power System Control; 2013, 3; s. 83-94
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu technicznego urządzeń bloków elektrowni Bełchatów w celu redukcji ryzyk eksploatacyjnych
The analysis of the technical condition of the power units of Bełchatów Power Station in order to reduce operational risk
Autorzy:
Oziemski, A.
Powiązania:
https://bibliotekanauki.pl/articles/309675.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
energetyka cieplna
bloki energetyczne
niezawodność eksploatacji
systemy elektroenergetyczne
thermal energetics
power blocks
reliability
power systems
Opis:
W artykule dokonano oceny niezawodności eksploatacyjnej bloków energetycznych zainstalowanych w Elektrowni Bełchatów, która po uruchomieniu w 2011 r. bloku 858 MW osiągnęła moc zainstalowaną 5298 MW i jest obecnie największą elektrownią na świecie wykorzystującą węgiel brunatny. Badania zostały przeprowadzone w oparciu o zarchiwizowane w komputerowej bazie danych populacje zdarzeń eksploatacyjnych, zaistniałych na wszystkich 13. blokach elektrowni od początku ich pracy do końca 2016 r.
The paper presents an assessment of the availability and failure indices of lignite power units installed in Bełchatów Power Station, which has reached a total installed capacity of 5298 MW, after opening of 858 MW unit, and is the biggest lignite fired power plant nowadays. Investigations have been performed on the basis of the computer database with operational statistics consisting of shutdown descriptions recorded at all of the 13 power units since their commissioning by the end of 2016.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 1196-1203, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do automatycznego pomiaru parametrów termicznych półprzewodnikowych przyrządów mocy
An automatic measurement system of thermal parameters of semiconductor power devices
Autorzy:
Bisewski, D.
Zarębski, J.
Powiązania:
https://bibliotekanauki.pl/articles/152727.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
parametry termiczne
rezystancja termiczna
przejściowa impedancja termiczna
półprzewodnikowe przyrządy mocy
thermal parameters
thermal resistance
transient thermal impedance
semiconductor power devices
Opis:
W pracy omówiono budowę i zasadę działania autorskiego systemu do automatycznego pomiaru parametrów termicznych, w tym czasowych przebiegów przejściowej impedancji termicznej oraz rezystancji termicznej półprzewodnikowych przyrządów mocy. W rozważanym systemie zaimplementowano popularną impulsową metodę pomiaru parametrów termicznych opartą na wykorzystaniu krzywej chłodzenia elementu półprzewodnikowego. Działanie systemu pomiarowego zilustrowano wynikami pomiarów parametrów termicznych wybranych półprzewodnikowych przyrządów mocy.
Generally, manufacturers of semiconductor devices do not provide in datasheets detailed information about thermal parameters of semiconductor devices, i.e. time waveform of junction-to-ambient transient thermal impedance or dependence of junction-to-ambient thermal resistance versus dissipated power. Therefore, the designers of electronic circuits do not have reliable information about thermal properties of semiconductor devices in the designed circuit [1 - 3]. The paper discusses the construction and operation of automatic measurement system of thermal parameters, including transient thermal impedance and thermal resistance of semiconductor power devices. Block diagram of the measurement system is shown in Fig. 1. In the measurement system, the popular Rubin and Oettinger [6] pulse method for measuring thermal parameters based on the cooling curve of semiconductor device, has been implemented. For reading and archiving the results of measurements, A/D and D/A converter USB-1608GX-2AO fabricated by Measurement Computing [5], has been used. Usefulness of the measuring system is illustrated by results of measurements of thermal parameters of silicon MOSFET (IRFR420A - International Rectifier), silicon carbide MESFET (CRF24010 - Cree) and silicon carbide Schottky diode (IDT06S60C - International Rectifier). As seen in Fig. 3, the thermal resistance junction-to-ambient strongly depends on semiconductor device dissipated power. For example, the thermal resistance of MOSFET decreases about 20% with increase of the dissipated power from 0.1 W to 1 W, at constant ambient temperature. It has been shown, that realization of such measurements allows to obtain more precise information about the thermal parameters of semiconductor devices in comparison to the device catalogue data.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 12, 12; 1150-1153
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault detection in measuring systems of power plants
Autorzy:
Głuch, J.
Powiązania:
https://bibliotekanauki.pl/articles/258570.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
steam turbines
turbines exploitation
power units
efficiency
thermal diagnostics
diagnostic relations
Opis:
This paper describes possibility of forming diagnostic relations based on application of the artifical neural networks (ANNs), intended for the identifying of degradation of measuring instruments used in developed power systems. As an example a steam turbine high-power plant was used. And, simulative calculations were applied to forming diagnostic neural relations. Both degradation of the measuring instruments and simultaneously occurring degradation of the measuring instruments and thermal cycle component devices, were taken into account. Good quality of diagnostic neural relations was stated. They make it possible to distinguish degradation of measuring instruments from degradation of thermal cycle components. The calculated errors of identification of dergraded devices and measuring instruments in the case of simultaneous occurence of three different degradations were on the level of 0.25 %. Performance of the relations was presented by using an example based on industrial practice.
Źródło:
Polish Maritime Research; 2008, 4; 45-51
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the thermal degradation process within the steam power plants heat exchangers
Autorzy:
Hajduk, T.
Powiązania:
https://bibliotekanauki.pl/articles/244895.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
steam power plants
fouling of heat transfer surface
thermal degradation determinants
Opis:
The consequence of the deposits presence on the heat transfer surface of the following heat exchangers: shell-and-tube condensers, the regenerative feed water exchangers, are commonly the loss of heat exchanger capacity, owing to the high value of heat conductive resistance of fouling. The process is more often defined as the thermal (heat) degradation of a given heat transfer device. The symptoms of heat degradation are usually defined as the difference between the values of thermal-flow parameters for the current and the reference state. Moreover, this process always entails an increase in the cost of energy conversion, leading to increasing the emission output of greenhouse gases consequently increasing the environmental degradation. It is worth mentioning that deposits settled on the waterside of heat transfer surface could also initiate the process of tubes obliteration. This phenomenon is characteristic for condensers cooled by seawater in particular. Reducing internal diameter of any single heat exchanger pipe by the deposits cause the rise in flow resistance and also reduce the condenser cooling water pump capacity. Ultimately, it leads to the reduction in water flow rate, resulting in an additional increase in the resistance of heat transfer. Furthermore, reducing the flow rate of cooling water causes the enhancement of the fouling settling rate. The paper describes the above-mentioned phenomena and presents the quantitative determinants of the thermal degradation description for heat exchangers based on the results of the author’s own experimental research.
Źródło:
Journal of KONES; 2016, 23, 4; 127-133
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power losses and windings temperature of an induction machine under voltage subharmonics
Autorzy:
Gnaciński, Piotr
Pepliński, Marcin
Hallmann, Damian
Powiązania:
https://bibliotekanauki.pl/articles/1819114.pdf
Data publikacji:
2020
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
induction motors
interharmonics
power quality
thermal stresses
voltage fluctuation
voltage waveform distortions
Opis:
This paper deals with the effect of voltage subharmonics on power losses and heating of an induction motor. An increase in power losses in stator and rotor windings and their impact on windings temperature is presented for subharmonics of various frequencies. The results of this study’s investigations are provided for subharmonics occurring as a single power quality disturbance and combined with voltage deviation. The appropriate electromagnetic computations were performed with the finite element method, and thermal ones – with an analytical method.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2020, 63 (135); 51-57
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the influence of output inductance on DBD plasma uniformit
Autorzy:
Hołub, M.
Powiązania:
https://bibliotekanauki.pl/articles/141400.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
non-thermal plasma
power electronic supply
plasma uniformity
dielectric barrier discharge reactors
Opis:
The presented work gives an overview on simulation and experimental results of the power supply parameters’ influence on DBD discharge uniformity. The proposed study is about the use of quasi-pulsed, power electronic power supply and a saturable inductor in series with the discharge cell [1]. The simulation results are presented with a parallel DBD reactor model with linear critical voltage distribution. A more uniform current waveform is observed, however, due to small reactor capacitances no streamer formation could be verified in calculations. An experimental test stand was prepared with a double dielectric barrier discharge arrangement. The experimental results are presented with regard to the electrical oscilloscope waveforms and ICCD camera imaging. A more homogenous plasma was observed in the case of saturable inductor with saturation current set at the point of discharge formation. Two possible mechanisms are connected with this phenomenon – inductive element current support during discharge and/or current rise-time limitation [1].
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 263-272
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PV/T Systems for Renewable Energy Storage: A Review
Autorzy:
Avijit, Mallik
Hasan, Md. Zahid
Powiązania:
https://bibliotekanauki.pl/articles/1177985.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
HVAC
PV/T System
Solar Heat Radiation
Solar Power
Thermal Energy System
Opis:
Sunlight is converted into electricity and heat simultaneously with the help of PV thermal panels. It is examined that the efficiency of the PV/T panel is higher than the separate PV panels and solar thermal collectors’ efficiency. The electricity conversion-efficiency for a PV system is about 6% to 15% and in moreover cases 85% of the incoming solar energy is either reflected or absorbed as heat energy. Now a day’s Renewable energy has become a hot topic. The energy researchers day by day making advanced researches to make this type of system a useable one. Non-renewable sources will be approximately finished within next 100-150 years. So this type of energy is very important for everyone. Normally researches are made on producing electricity from renewable sources like sun-light, wind energy, tidal energy and etc. In this paper there is a compact review of solar photovoltaic thermal system. The performance of the solar cell decreases with the increasing of temperature. Both the electrical efficiency and the power output of PV module depend on the operating temperature. Photovoltaic thermal hybrid solar collectors, also known as hybrid PV/T systems are systems in which sunlight is converted into thermal and electrical energy both. This paper contains a combination of basic and advanced hybrid PV/T systems that are usable in Asian region.
Źródło:
World Scientific News; 2018, 96; 83-95
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozszerzenie zakresu badań alternatora o diagnostykę termowizyjną na stanowisku laboratoryjnym
Extending the scope of research of thermal imaging diagnostics of an alternator on a laboratory stand
Autorzy:
Plich, M.
Stypułkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/249758.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
alternator
obwód zasilania
diagnostyka termowizyjna
termogram
power supply circuit
thermal imaging
thermogram
Opis:
W artykule przedstawiono aktualne możliwości pomiarowe istniejącego stanowiska laboratoryjnego do badań charakterystyk alternatorów wraz z symulacją usterek w obwodzie zasilania. Modułowa budowa tego stanowiska umożliwia rozszerzenie jego funkcji pomiarowych i badawczych o diagnostykę termowizyjną. Takie rozszerzenie zakresu badań alternatora umożliwia również wzbogacenie programu dydaktycznego prowadzonych ćwiczeń laboratoryjnych. Zaprezentowano również przykładowe termogramy wykonane na tym stanowisku.
The paper presents current ability of measurement of the existing laboratory stand using for testing the characteristics of alternators and for simulating faults in a power supply circuit. The modular design of the stand allows to extend its measurement functionality and research of thermal imaging diagnostics. This extension of the scope of research an alternator also allows to enrich of the teaching program conducted in the laboratory. The examples of thermal images were taken on presented laboratory stand.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 1241-1244, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola małych miast w kształtowaniu rozproszonej sieci energetycznej opartej na lokalnej biomasie
The Role of Small Towns in Shaping Distributed Generation Based on Local Biomass
Autorzy:
Jasiulewicz, Michał
Janiszewska, Dorota A.
Powiązania:
https://bibliotekanauki.pl/articles/591306.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Ekonomiczny w Katowicach
Tematy:
Biomasa
Energia cieplna
Energia elektryczna
Miasto
Biomass
City
Electric power
Thermal energy
Opis:
Poland is one of the countries with an evenly spaced settlement grid. District heating systems that are placed in over 300 towns in Poland create the possibility of biomass usage in a distributed generation system. The needs of distributed generation are to be satiated using all kinds of lignocellulosic wastes, manure, as well as energy crops processed into wood chips. To ensure that the usage of biomass would be financially justified it is essential to decrease the distances between the places producing raw materials and the heat generating plants.
Źródło:
Studia Ekonomiczne; 2013, 144; 287-297
2083-8611
Pojawia się w:
Studia Ekonomiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kamery termowizyjne w ocenie jakości energii elektrycznej
Thermal Imaging Cameras in the Evaluation of Electric Power Quality
Autorzy:
Łatka, M.
Piechota, T.
Powiązania:
https://bibliotekanauki.pl/articles/159626.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
jakość energii elektrycznej
kamera termowizyjna
monitoring parametrów jakości energii elektrycznej
electrical power quality
thermal imaging camera
power quality monitoring
Opis:
Kamery termowizyjne okazują się być bardzo skutecznymi narzędziami diagnostycznymi w elektroenergetyce. Coraz częściej wykorzystuje się je do bezdotykowych pomiarów stanu urządzeń elektroenergetycznych w stacjach transformatorowych, rozdzielniach itd. Na podstawie otrzymanych obrazów termowizyjnych można ocenić stan urządzeń tam znajdujących się. Czy również takie obrazy termowizyjne mogą posłużyć do oceny jakości energii elektrycznej w wybranym punkcie systemu elektroenergetycznego? Otóż okazuje się, że jak najbardziej. W artykule zaprezentowano zasady przeprowadzania pomiarów oraz wyniki pomiarów kamerą termowizyjną, w postaci obrazów termowizyjnych i ich analizę pod kątem oceny jakości energii elektrycznej w wybranych punktach systemu elektroenergetycznego. Otrzymywane, w bardzo szybki, bezdotykowy i w sumie tani sposób obrazy termograficzne mogą być wskazaniem do przeprowadzenia dalszych, bardziej zaawansowanych pomiarów w zakresie jakości energii elektrycznej.
Thermal imaging cameras prove to be an effective diagnostic instruments in the electric power engineering. These cameras are used more and more frequently in taking touchless measurements of the state of electric power devices in transformer stations, distribution points, etc. On the basis of the received thermal images, it is possible to evaluate the condition of the devices which are located there. Are such images able to serve in the evaluation of the electrical energy quality at the given point of the electric power system? The answer proves to be in the affirmative. In the article, the principles and the results of measurements that have been taken with the thermal imaging camera are presented. The results are delivered as thermal images and their analysis is provided on the basis of the electric power quality at given points of the electric power system. The results, which have been achieved in a quick, touchless and overall inexpensive way, might be an indication to take further, more advanced measurements in the area of electric power quality.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 272; 83-92
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determinanty procesu degradacji termicznej aparatów wymiany ciepła w siłowniach parowych
The Heat Exchanger Thermal Degradation Process Determinants within the Steam Power Plants
Autorzy:
Hajduk, T.
Powiązania:
https://bibliotekanauki.pl/articles/342415.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Morski w Gdyni. Wydawnictwo Uniwersytetu Morskiego w Gdyni
Tematy:
siłownie parowe
wymienniki ciepła
degradacja cieplna
steam power plants
heat exchangers
thermal degradation
Opis:
Obecność zanieczyszczeń na powierzchniach wymiany ciepła aparatów wymiany ciepła w okrętowych i lądowych siłowniach parowych jest przyczyną m.in. wzrostu spiętrzeń temperatur oraz związanego z tym pogorszenia stopnia próżni w skraplaczach. W końcowym efekcie proces degradacji termicznej wymienników ciepła prowadzi do zmniejszenia sprawności danego układu cieplnego. Symptomy degradacji termicznej najczęściej definiowane są jako różnica między wartościami parametrów cieplno-przepływowych dla stanu referencyjnego i wartościami dla stanu aktualnego. W efekcie końcowym zjawisko degradacji cieplnej pociąga za sobą wzrost kosztów przetwarzania energii, a w konsekwencji prowadzi do zwiększonej degradacji środowiska naturalnego. W artykule opisano powyższe zjawiska oraz zaprezentowano determinanty degradacji termicznej wymienników ciepła siłowni parowych, opierając się na rezultatach własnych badań eksperymentalnych.
he deposits presence on the heat transfer surfaces of the heat exchangers within the stationary and the ship steam power plants cause an inscrease in terminal temperature difference values and entails a decrease of the vacuum level, as well. That fact leads to reducing the total efficiency of the thermal unit. Symptoms of heat degradation are usually defined as the difference between the values of thermal-flow parameters for the current and the reference state. Moreover, thermal degradation of any heat transfer device always entails an increase in the cost of energy conversion, leading to increasing the emission output of greenhouse gases and finally increasing the environmental degradation process. The above-mentioned phenomena, the determinants of the thermal degradation as well as the results of the author’s own experimental research have been presented in the paper.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Gdyni; 2017, 100; 87-99
1644-1818
2451-2486
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Gdyni
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of energy potential of three ways of configuration of a condenser power plant thermal cycle
Autorzy:
Chmielniak, T.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/258540.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Comparative analysis of energy
condenser
power plant
thermal cycle
new regeneration
separation preheater
Opis:
A theoretical, comparative analysis of three configuration ways of a condenser power plant thermal cycle is shown in the work. A new regeneration & separation preheater and its application in a thermal cycle is presented. Results obtained allow to compare all three analysed configurations efficiencies.
Źródło:
Polish Maritime Research; 2008, 4; 30-36
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nuclear power plant as a source of electrical energy and heat
Wykorzystanie elektrowni jądrowej jako źródła energii elektrycznej i cieplnej
Autorzy:
Minkiewicz, T.
Reński, A.
Powiązania:
https://bibliotekanauki.pl/articles/172853.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownie jądrowe
energia elektryczna
energia cieplna
nuclear power plants
electrical energy
thermal energy
Opis:
In this paper, certain the issues concerning usage of nuclear power plants as sources of not only electric power but also thermal energy will be discussed. For such a solution appeals most of all the need to limit harmful emissions of gases (including C02) and ashes, which come from the process of burning fossil fuels, as well as the raising demand for network heat and chill. Additionally combined heat and power production brings measurable economic benefits and increases energy security in the given region. In particular, the possibility of operating a nuclear power plant (NPP) as a source of heat for the heating network system of an agglomeration and the most probable locations for this plant in Pomeranian Voivodeship are considered. Both technical and economic aspects of such an undertaking are taken into account.
Rozpatrzono wybrane problemy eksploatacji elektrowni jądrowych, wykorzystywanych nie tylko jako źródło energii elektrycznej, ale również i cieplnej. Za takim rozwiązaniem przemawia przede wszystkim konieczność ograniczenia emisji szkodliwych gazów (w tym CO2)) i pyłów powstających w procesie spalania paliw kopalnych, a także rosnące zapotrzebowanie na ciepło czy też chłód sieciowy. Dodatkowo praca w skojarzeniu przynosi wymierne korzyści ekonomiczne, a także zwiększa bezpieczeństwo energetyczne w danym rejonie. W szczególności rozważono możliwość wykorzystania elektrowni jądrowej jako źródła ciepła dla systemu ciepłowniczego aglomeracji miejskiej, biorąc pod uwagę najbardziej prawdopodobne lokalizacje tej elektrowni w województwie pomorskim. Uwzględniono zarówno aspekty techniczne, jak i ekonomiczne tego przedsięwzięcia.
Źródło:
Archiwum Energetyki; 2011, 41, 3-4; 155-166
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal properties of natural ester and low viscosity natural ester in the aspect of the reliable operation of the transformer cooling system
Właściwości cieplne estru naturalnego i estru naturalnego o obniżonej lepkości w aspekcie niezawodności działania układu chłodzenia transformatora
Autorzy:
Dombek, Grzegorz
Nadolny, Zbigniew
Marcinkowska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/301946.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
natural ester
dielectrics
power transformer
thermal properties
ester naturalny
dielektryki
transformator
właściwości cieplne
Opis:
The paper presents the results of comparative studies of thermal properties of various types of natural esters used as electroinsulating liquids in transformers. Adequate thermal properties of electro-insulating liquids ensure reliable work of transformers. Two natural esters were selected for the study – one commonly used in distribution transformers, the other characterized by low viscosity. Fourier Transform Infrared Spectroscopy and UV-Visible spectroscopy were used to examine the chemical structure of the examined esters. Properties such as thermal conductivity coefficient λ, kinematic viscosity υ, specific heat cp, density ρ, and thermal expansion coefficient β were analyzed. Heat transfer factor α of the liquid was calculated on the basis of obtained properties. This factor defines the ability of an insulating liquid to heat transport in the transformer, thus determining its reliability. The authors put forward a thesis that a low viscosity natural ester will have a higher heat transfer factor α due to its low viscosity, which affects the factor α. The analysis of thermal properties was carried out for the following temperatures: 25, 40, 60, and 80°C. On the basis of the calculated factor α, the temperature drops in the transformer filled with the analyzed types of natural esters were determined. It has been shown that if a low viscosity natural ester is used in the cooling system of the transformer, the temperature of the hot-spot will be lower. This fact may contribute to more reliable work of transformers and extend its service life.
W pracy przedstawiono wyniki badań porównawczych właściwości cieplnych różnego rodzaju estrów naturalnych stosowanych jako ciecze elektroizolacyjne w transformatorach. Odpowiednie właściwości cieplne cieczy elektroizolacyjnych zapewniają niezawodną pracę transformatorów. Do badań wybrano dwa estry naturalne – jeden powszechnie stosowany w transformatorach rozdzielczych, drugi charakteryzujący się obniżoną lepkością. Do analizy struktury chemicznej badanych estrów wykorzystano spektroskopię w podczerwieni z transformatą Fouriera (FT-IR) oraz spektroskopię w ultrafiolecie i świetle widzialnym (UV-VIS). Analizowanymi właściwościami cieczy były przewodność cieplna λ, lepkość kinematyczna υ, ciepło właściwe cp, gęstość ρ oraz rozszerzalność cieplna β. Na podstawie przedstawionych właściwości cieplnych obliczono współczynnik przejmowania ciepła α. Współczynnik ten określa zdolność cieczy elektroizolacyjnej do transportu ciepła w transformatorze, a tym samym określa jego niezawodność. Autorzy postawili tezę, że ester naturalny o obniżonej lepkości będzie miał wyższy współczynnik przejmowania ciepła α ze względu na jego obniżoną lepkość. Analizę właściwości cieplnych przeprowadzono dla czterech wartości temperatury: 25, 40, 60 i 80°C. Na podstawie obliczonego współczynnika α określono spadki temperatury w transformatorze wypełnionym analizowanymi estrami naturalnymi. Wykazano, że jeżeli w układzie chłodzenia transformatora stosowany jest ester naturalny o obniżonej lepkości, wówczas temperatura najgorętszego miejsca (ang. hot spot) będzie niższa. Fakt ten może przyczynić się do zwiększenia niezawodności pracy transformatorów i przedłużyć okres ich eksploatacji.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 3; 384-391
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Źródła plazmy nietermicznej dla technologii ochrony środowiska
Autorzy:
Hołub, M.
Kalisiak, S.
Jakubowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/266513.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
plazma nietermiczna
energoelektroniczne układy zasilające
non-thermal plasma systems
power electronic supply systems
Opis:
W większości instalacji wykorzystujących technicznie plazmę nietermiczną używa się wzbudzenia poprzez pole elektryczne. Szczególnie dynamicznie rozwijającym się polem zastosowań są układy przeznaczone do generacji plazmy nietermicznej na potrzeby technologii ochrony środowiska. Artykuł prezentuje krótki przegląd typowych źródeł, podając jednocześnie podstawowe, wykorzystywane w poszczególnych przypadkach układy zasilające ze szczególnym uwzględnieniem zasilaczy energoelektronicznych. Jako ilustrację wpływu doboru układu zasilającego do konkretnej aplikacji zaprezentowano wyniki pomiarów elektrycznych oraz kamerą iCCD pojedynczego układu rozładowczego dla różnych kształtów i typów napięcia.
Proposed article describes basic properties of different supply systems for non-thermal, atmospheric pressure plasma devices. Different approaches are given ranging from AC supply, pulsed supplies, microwave beams and electron-beam sources with their basic electric properties. Main supply system configurations are given and typical reactor constructions are discussed with their basic properties. As an example a laboratory discharge cell investigations are presented having different supply voltage and current waveforms. ICCD camera imaging gives a clear evidence on supply voltage shape importance. Pulsed supply with large leakage inductance on the secondary side of a high-voltage transformer yields a more diffuse character. AC supply results in a well-known filamentary discharge with typical streamer channels.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 27; 27-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical method for determining the allowable medium temperature during transient operation of a thick-walled boiler element in power plant
Autorzy:
Rząsa, D.
Duda, P.
Powiązania:
https://bibliotekanauki.pl/articles/240222.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia
naprężenie cieplne
optymalizacja
wymiana ciepła
heat transfer
optimization
power plant
thermal stresses
Opis:
Secure and cost-effective power generation has become very important nowdays. Care must be taken while designing and operating modern steam power plants. There are regulations such as German boiler regulations (Technische Regeln fur Dampfkessel 301) or European Standards that guide the user how to operate the steam power plants. However, those regulations are based on the quasi-steady state assumption and one dimensional temperature distribution in the entire element. This simplifications may not guarantee that the heating and cooling operations are conducted in the most efficient way. Thus, it was important to find an improved method that can allow to establish optimum parameters for heating and cooling operations. The optimum parameters should guarantee that the maximum total stresses in the construction element are in the allowable limits and the entire process is conducted in the shortest time. This paper summarizes mathematical descriptions how to optimize shut down process of power block devices. The optimization formulation is based on the assumption that the maximum total stresses in the whole construction element should be kept within allowable limits during cooling operation. Additionally, the operation should be processed in the shortest time possible.
Źródło:
Archives of Thermodynamics; 2011, 32, 4; 91-99
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ jakości pomiarów eksploatacyjnych bloków energetycznych na wyznaczanie symptomów niesprawnej pracy
Influence of exploitation power units measurements quality on determination of inefficient operation symptoms
Autorzy:
Głuch, J.
Powiązania:
https://bibliotekanauki.pl/articles/257568.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
turbina parowa
energetyka
diagnostyka cieplno-przepływowa
pomiar cieplny
heat and flow diagnostics
thermal measurements
power systems
exploitation of power systems
Opis:
W pracy opisano jedną z metod zminimalizowania błędów pomiarowych pojawiających się przy funkcyjnym wyznaczaniu wzorca sprawnej pracy obiektów energetycznych dużej mocy. Zajęto się problemem oceny jakości pomiarów związanej z występującą koniecznością okresowych wymian czujników pomiarowych ze względu na ich rozkalibrowywanie eksploatacyjne. Przedstawiono obliczenia symulacyjne wpływu takich wymian na niepewność wyznaczania wzorca sprawnej pracy bloku energetycznego turbiny parowej o mocy 200 MW. Wyniki symulacji potwierdzają dobre perspektywy rozwijania zaproponowanej metody.
The paper presents one of the possible methods for the minimization of measurement errors occurring at the time of determination of model efficient operation of high power objects by means of mathematical functions. The problem of measurement quality assessment connected with the need for periodical exchange of measurement sensors caused by their operational decalibration is discussed. The article also presents the results of simulation calculations for the influence such changes have on the determination of the model effective operation of a 200MW power unit of the steam turbine. The results of conducted simulation confirm good perspectives for the development of the method proposed.
Źródło:
Problemy Eksploatacji; 2011, 2; 73-86
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Siłownia parowa z wieloźródłowym zasilaniem
Vapour power plant utilizing multiple energy sources
Autorzy:
Nowak, W.
Wiśniewski, S.
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/173152.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
siłownia parowa
siłownia ORC jednobiegowa
siłownia binarna
obliczenia cieplno-przepływowe
vapour power plant
single cycle ORC power plant
binary power plant
thermal and flow calculations
Opis:
W pracy przedstawiono wyniki obliczeń umożliwiające ocenę efektywności pracy siłowni parowej obejmującej jednoobiegową siłownię ORC (organic Rankine cycle) z parowaczem o cyrkulacji wewnętrznej, sprzężonej cieplnie z dolnym obiegiem siłowni binarnej. Rozpatrywane zagadnienie dotyczy wykorzystania dwóch różnotemperaturowych źródeł ciepła do zasilania obiegów organicznych analizowanego układu. Nośnikami energii pomiędzy źródłami ciepła a obiegiem jednoobiegowej siłowni ORC oraz dolnym obiegiem siłowni binarnej są odpowiednie strumienie wody. Omówione rozwiązanie polegające na zastosowaniu w jednoobiegowej siłowni ORC parowacza z cyrkulacją wewnętrzną nośnika energii, który umożliwia dostosowanie temperatury strumienia wody opuszczającej parowacz do wartości odpowiadającej temperaturze strumienia wody zasilającej podgrzewacz dolnego obiegu siłowni binarnej. W związku z tym możliwe jest skierowanie części strumienia wody zasilającej siłownię jednoobiegową do podgrzewacza dolnego obiegu siłowni binarnej. Podano przykłady obliczeniowe potwierdzające korzyści płynące z takiego rozwiązania.
In the paper, calculation results are presented to enable an assessment of the effectiveness of the vapour power plant that consists of the single cycle ORC power plant incorporating the evaporator with internal circulation and of the bottoming binary power plant, whereby the latter two power plants are thermally coupled, but are driven by two heat sources with different temperatures. Water is used as heat carrier from both the heat sources. The ORC power plant solution with the evaporator, that works with the internal circulation is presented in detail. Evaporator of this type enables to adjusted its outlet water temperature to the value of the temperature of the heat carrier delivered to the bottoming binary power plant, whereby part of the evaporator outlet water can be supplied to the preheater of that plant. Advantages of the above solution are confirmed by the results of the calculated exemplary cases.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 103-112
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór materiałów do wytworzenia pasywnych celów kalibracyjnych oraz metodyka wyznaczania terenowej zdolności rozdzielczej kamer i skanerów termalnych
Selection of materials for the development of passive calibration targets and the methodology used in determining the spatial resolution of thermal cameras and scanner
Autorzy:
Dębski, W.
Walczykowski, P.
Orych, A.
Powiązania:
https://bibliotekanauki.pl/articles/131068.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
sensor termalny
cel kalibracyjny
terenowa zdolność rozdzielcza
MTF
thermal sensor
calibration target
resolving power
Opis:
Precyzyjne wyznaczenie terenowej zdolności rozdzielczej sensorów termalnych jest problemem niezwykle istotnym przy pozyskiwaniu zobrazowań z pułapu lotniczego. Artykuł przedstawia możliwości wyznaczania terenowej zdolności rozdzielczej sensorów termalnych w oparciu o specjalnie do tego celu zaprojektowane testy kalibracyjne. Przedstawiono rodzaje istniejących termalnych celów kalibracyjnych. W artykule zostały omówione i przeanalizowane dwie podstawowe metody wyznaczania rozdzielczości terenowej na podstawie zobrazowań celów kalibracyjnych – metoda subiektywna oraz metoda obiektywna. Dokonano analizy istniejących pasywnych celów termalnych wykorzystywanych przez międzynarodowe zespoły Traktatu Open Skies. Cele, które spełniają rygorystyczne wymogi Traktatu są jednak przeważnie mało mobilne. Dlatego też prowadzone są dalsze prace nad doborem odpowiednich materiałów do wytworzenia pasywnych celów kalibracyjnych. W wyniku analizy danych pozyskanych z pomiarów Open Skies oraz własnych opracowań, można stwierdzić, że najwygodniejszym rozwiązaniem jest wykorzystanie materiałów tekstylnych do wykonania termalnych celów kalibracyjnych. Cele kalibracyjne wykorzystywane przez uczestników Traktatu Open Skies uniemożliwiają określenia zdolności rozdzielczej sensora dla dowolnej wysokości lotu. W artykule przedstawiono metodykę obiektywnego określania zdolności rozdzielczej sensora termalnego na dowolnym pułapie lotu na podstawie tkaninowych testów Siemmensa i przekoszkonej krawędzi wykorzystując do tego celu funkcję przenoszenia modulacji.
Precise determination of the resolving power of thermal sensors is of a key importance when acquiring imagery from the air. The resolving power defines the value of such imagery in many applications. The paper describes possibilities of determining the resolving power of thermal sensors based on especially designed calibration tests. The existing thermal calibration targets are presented. The paper describes and analyses two basic methods of determining the resolving power based on calibration targets: a subjective method of multiple observations and an objective method, which uses the modulation transfer function (MTF). The existing passive thermal targets used by international Open Skies Treaty groups were analysed. The targets, which comply to the rigorous requirements of the Treaty, are usually made of large metal panels, which makes them difficult to transport. Therefore research is in progress on the selection of adequate materials for the production of calibration targets. In the experimental section, a large array of materials such as textiles as well as panels made out of wood, steel and aluminium of different finishes and covered with paints of different emissivities, were examined in the thermal range. Analysis of the authors' own measurements as well as those taken by Open Skies groups allows to conclude that the use of textiles is the most convenient solution for developing a thermal calibration target. Such a target is easy to transport and very convenient to experiment with in the field. Furthermore, development of such a target is simple and does not require any complex, specialised production methods. Calibration targets used by the Open Skies Treaty members make it possible to only subjectively establish the flight altitude, for which the resolving power of the sensor will not exceed 40, 50 or 60cm. They do not, however, allow to determine the resolving power of the sensor for any given flight altitude. The paper presents also an objective method for determining the resolving power of thermal sensors for any flight altitude based on the modulation transfer function used on two textile targets: a Siemmens star and slanted edge test.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2008, 18a; 73-81
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania wód termalnych na obszarze gminy Lesznowola
Assessment of the possibilities of using thermal water in the Lesznowola commune area
Autorzy:
Socha, M.
Szuflicki, M.
Gryszkiewicz, I.
Sokołowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/203588.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wody termalne
Lesznowola
ocena potencjału geotermalnego
efektywność ekonomiczna geotermii
thermal waters
potential assessment
power engineering
Opis:
W artykule zostały przedstawione dane dotyczące potencjału wód termalnych na terenie gminy Lesznowola i w jej bliskim sąsiedztwie. Pod względem tektonicznym analizowany rejon znajduje się w centralnej części niecki warszawskiej, administracyjnie zaś należy do powiatu piaseczyńskiego i zaliczany jest do aglomeracji warszawskiej. Na podstawie informacji z Banku Danych Wód Podziemnych Zaliczonych do Kopalin (http://spdpsh.pgi.gov.pl/) oraz opracowań archiwalnych oszacowano parametry hydrogeologiczne i złożowe zbiorników geotermalnych znajdujących się w obrębie gminy Lesznowola. Na tej podstawie określono możliwości eksploatacyjne wód termalnych z poszczególnych zbiorników. Po oszacowaniu nakładów inwestycyjnych i kosztów eksploatacyjnych wyliczono prawdopodobny koszt produkcji 1 GJ ciepła z wybranych poziomów wodonośnych. Umożliwiło to wskazanie najbardziej perspektywicznych zbiorników oraz kierunków wykorzystania wód termalnych w Lesznowoli. Na podstawie obliczonych wartości i zgromadzonych danych uznano zbiornik geotermalny jury dolnej jako optymalny do zagospodarowania i zaproponowano wykorzystanie jego wód w pierwszej kolejności do celów ciepłowniczych oraz w rekreacji i balneoterapii.
The article presents data concerning the potential of thermal waters in Lesznowola commune and in its close vicinity. In terms of tectonics, the analyzed region is located in the central part of the Warsaw Basin, and belongs to the Piaseczno County of the Warsaw agglomeration. On the basis of information from the Mineral and Thermal Groundwater Database and archive studies, the hydrogeological parameters of geothermal reservoirs located within the Lesznowola commune were estimated. The exploitation possibilities of thermal waters from individual reservoirs were determined. After the estimation of investment efforts and operating expenses, the costs and the probable heat production of 1 GJ from the selected aquifers were calculated. This allowed the most prospective reservoirs and usage directions for thermal waters in Lesznowola to be identified. Based on the calculated values and the collected data, the geothermal reservoir of the Lower Jurassic area was considered as optimal for development and the use of those waters for heating purposes was proposed, as well as in recreation and balneotherapy.
Źródło:
Technika Poszukiwań Geologicznych; 2018, R. 57, nr 1, 1; 87-103
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary rezystancji termicznej tranzystorów mocy z wykorzystaniem metod pirometrycznych
Application of the pirometric methods for the thermal resistance of power transistors measurements
Autorzy:
Górecki, K.
Zarębski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157592.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary rezystancji termicznej tranzystorów
metody pirometryczne
application of pirometric methods
thermal resistance
power transmitors measurements
Opis:
Praca dotyczy pomiarórw rezystancji termicznej wybranych tranzystorów mocy przy wykorzystaniu metod pirometrycznych. Zamieszczono szereg wyników pomiarów tego parametru w funkcji mocy wydzielanej w elemencie, uzyskanych przy zastosowaniu różnych radiatorów obudów i orientacji przestrzennej badanych tranzystorów. Zbadano również nierównomierność przestrzennego rozkładu temperatury w badanej strukturze.
In this paper the problem of measurements of the thermal resistance (Rth) of the selected power transistors with the use of the pirometric method is considered. The measuremental results Rth of bipolar transistors 2N3055 and MOS transistors IRF840 for the dissipated power changing as well as for the various kinds of device cases the temperature distribution on the chip has been estimated.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 1, 1; 41-44
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the mounting manner on thermal and optical parameters of power LEDs
Autorzy:
Górecki, K.
Ptak, P.
Powiązania:
https://bibliotekanauki.pl/articles/397969.pdf
Data publikacji:
2015
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
power LEDs
thermal parameters
optical parameters
measurements
diody LED mocy
parametry cieplne
parametry optyczne
pomiary
Opis:
The paper refers to the investigation results concerning thermal and optical properties of power LEDs. The measuring-set to measure thermal and optical parameters of the considered semiconductor devices is described and some results of measurements of transient thermal impedance and illuminance emitted by power LEDs operating at different cooling conditions are presented. Investigations were performed both for LEDs operating solely and sets of such diodes situated on the common heat-sink.
Źródło:
International Journal of Microelectronics and Computer Science; 2015, 6, 1; 23-28
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of thermal processing on antioxidant power and thiosulfinate content in Brussels sprouts juices
Autorzy:
Kot, M.
Olech, Z.
Powiązania:
https://bibliotekanauki.pl/articles/410496.pdf
Data publikacji:
2017
Wydawca:
Politechnika Łódzka. Wydawnictwo Politechniki Łódzkiej
Tematy:
Brussels sprouts
antioxidant power
thiosulfinates
thermal processing
DPPH
kapusta brukselska
moc przeciwutleniająca
tiosulfiniany
obróbka termiczna
Opis:
The aim of this study was to elucidate the influence of thermal processing at 22-95°C on the antioxidant ability of Brussels sprouts juice and its thiosulfinate content. The antioxidant power was determined by FRAP, Folin-Ciocalteu and DPPH radical scavenging methods. Thiosulfinate concentration was assayed by Han's procedure. It was shown that the increase of processing temperature decreased of the antioxidant ability determined by Folin-Ciocalteu method. However, FRAP and DPPH scavenging showed increase by 20% of the antioxidant power in the final heating step (95°C). The increasing processing temperature resulted in decreasing thiosulfinate concentration until the total loss. This proved that the thiosulfinate present in Brussels sprouts juice is thermolabile compound (not resistant for high temperature). The total loss of the thiosulfinate in high temperature did not reflect the change in antioxidant power. This fact indicated that there was no impact of the thiosulfinate on antioxidant abilities of Brussels sprouts juice or the impact was insignificant among the abundance of other antioxidants. The results showed a good correlation between FRAP and DPPH assays of antioxidant power determination in contrast to correlation with the data of Folin-Ciocalteu procedure.
Źródło:
Biotechnology and Food Science; 2017, 81, 2; 83-92
2084-0136
2299-6818
Pojawia się w:
Biotechnology and Food Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal aspects of operation of the selected photovoltaic components
Autorzy:
Głuchy, A.
Kurz, D.
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/97586.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
photovoltaics
solar collector
Photovoltaic Thermal
PV temperature
photovoltaic roofing tile
power yield
efficiency
roof substrate
Opis:
In the study the authors introduced the idea of the operation of the photovoltaic system with possibly low temperature of photovoltaic cell surfaces. The attention was paid both to PV panels which are very popular in Poland and to currently less popular PV roofing tiles. The selected solutions were characterized, which - in the authors’ opinion - have a practical impact on lowering of the temperature of operation of photovoltaic cells, and thus increase the system’s energy yield. Special attention was paid to the concept of operation of the hybrid PVT collector as well as the selection of roof substrate for PV roofing tiles. Potential benefits resulting from conducted works were indicated for various groups of recipients. The results of first tests and calculations were also presented, which confirm the need of further research works on this issue.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 484-496
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of thermal impedance to inverse heat transfer modeling of power cables
Zastosowanie impedancji termicznej do modelowania cieplnych problemów odwrotnych kabli energetycznych
Autorzy:
Więcek, B.
Strąkowska, M.
De Mey, G.
Chatziathanasiou, V.
Chatzipanagiotou, P.
Powiązania:
https://bibliotekanauki.pl/articles/152880.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IR thermography
power cables
thermal impedance
Fourier analysis
forward and inverse thermal modeling
termografia w podczerwieni
impedancja termiczna
proste i odwrotne modelowania termiczne
Opis:
This paper presents the inverse heat transfer modeling in applications to the power cables. In order to simplify the calculations, the inverse modeling implements thermal simulations in frequency domain. Due to the cylindrical summery of the power cable, this model has an analytical solution, which simplifies using Bessel functions. The inverse model allows estimating the thermal parameters of the material the cable is made of. It can be used for defect detection and aging of the cable. The model was made in Matlab®, and compared with the results obtained from COMSOL® simulation software.
W pracy przedstawiono zastosowanie modelowania cieplnych zjawisk odwrotnych do wyznaczania wartości parametrów termicznych kabli energetycznych. W procesie modelowania odwrotnego struktury wykorzystano model w dziedzinie częstotliwości, który dla struktury o symetrii cylindrycznej ma rozwiązanie analityczne przy użyciu funkcji Bessela. Model termiczny wraz z optymalizacją opracowano w programie Matlab®. Wyniki modelowania odwrotnego zweryfikowano rezultatami uzyskanymi z symulacji 3D wykonanych za pomocą oprogramowania COMSOL® oraz za pomocą danych pomiarowych, uzyskanych z kamery termowizyjnej. Opracowana metoda może być wykorzystana w praktyce do oceny stanu kabli energetycznych, ich zużycia, do wykrywania defektów związanych np. z korozją oraz do oszacowania warunków odprowadzania ciepła z kabli do otoczenia. W konsekwencji na podstawie wyników termowizyjnych można wyuczyć wartość impedancji termicznej kabla, co pozwoli oszacować maksymalną wartość temperatury w określonych warunkach pracy. Na obecnym etapie badań wykonano model kabla z litego materiału. Kolejnym krokiem będzie opracowanie modelu kabla wielowarstwowego, w tym z izolacją o małej przewodności cieplnej.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 9, 9; 946-949
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal properties of nanoliquids prepared on the basis of natural ester modified by nanoparticles TiO2 and C60
Autorzy:
Dombek, G.
Powiązania:
https://bibliotekanauki.pl/articles/97730.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
natural esters
thermal conductivity
viscosity
density
specific heat
high voltage power transformers
heat transfer coefficient
nanoliquids
Opis:
In this paper the results of the researches concerning thermal properties of insulting nanoliquids received on the basis of natural ester, titan dioxide TiO2 and fullerene C60 were presented. Thermal conductivity, viscosity, density and specific heat are these thermal properties. The range of the temperature was changing from 25°C to 80°C. These properties are crucial from the viewpoint of heat transfer coefficient by insulating liquid used in insulating system of power equipment; thus, they influence on temperature distribution inside the equipment. The possibility of receiving steady nanoliquids was also analyzed. The impact of natural ester modification by nanoparticles and surfactant on thermal properties of received nanoliquids was proved.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 404-413
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of assembly technology on exploitation parameters of power SSL-LEDs
Wpływ technologii montażu na parametry eksploatacyjne SSL LED-ów mocy
Autorzy:
Grzesiak, W.
Cież, M.
Koprowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/192268.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
diody mocy LED
montaż
parametr eksploatacyjny
rezystancja termiczna
power SSL-LED
assembly technology
exploitation parameters
thermal resistance
Opis:
The SSL-LEDs (Solid State Lighting LEDs), often of several watts consumed unit power are generally fixed to a cooling substrate to increase the on LEDs' durability, reliability and light efficiency. The size, shape, cooling area and ventilating properties of the substrate, made mainly of aluminum or copper, have to be taken into account. The next problem is the thermal resistance minimizing between the LEDs body and the substrate. Here the out growth is the choice of a LEDs fixing method. The work deals with six fixing methods and reports their properties, achieved by reducing the thermal resistance between LED and the radiator's substrate. The first method consists in purely mechanical fixing by screws. The second is completed by a silicon film. The third one utilizes a foil of excellent thermal resistivity, covered on both sides with an acrylic glue. The fourth simple method bases solely on of an acrylic glue. The fifth method consists in using a resin with aluminum powder and cured at room temperature. The last method makes use of a special silicon CAF-1 type glue. In all cases identical LEDs, radiators and applied powers were used and results compared.
Półprzewodnikowe diody mocy LED bywają mocowane zwykle do chłodzącego podłoża celem zwiększenia ich trwałości, niezawodności i sprawności. Rozmiary, kształt, powierzchnia chłodzenia i własności chłodzące podłoża, wykonanego zwykle z aluminium lub miedzi winny być starannie analizowane. Dalszym problemem jest rezystancja termiczna pomiędzy korpusem diody, a podłożem. Wiąże się ona ze sposobem jej mocowania. Praca omawia sześć metod mocowania i relacjonuje ich wpływ na rezystancję termiczną pomiędzy diodą a podłożem radiatorowym. Metoda pierwsza polega na czysto mechanicznym mocowaniu wkrętami. Druga wprowadza cienką warstewkę silikonu. Metoda trzecia stosuje folię o dobrej przewodności cieplnej, pokrytą obustronnie klejem akrylowym. Czwarta, prosta metoda bazuje wyłącznie na spoiwie akrylowym. Piąta metoda polega na sklejaniu żywicą zmieszaną z pyłem aluminiowym i utwardzaną w temperaturze pokojowej. Metoda szósta wykorzystuje specjalny klej silikonowy typu CAF-1. We wszystkich przypadkach użyto identycznych diod LED, radiatorów i aplikowanych mocy świecenia, a rezultaty prób przedstawiono i skomentowano.
Źródło:
Materiały Elektroniczne; 2008, T. 36, nr 4, 4; 124-132
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opracowanie nowych technologii wykonywania izolacji cieplnych w energetyce
New, environmentally friendly technologies of thermal insulation for power industry
Autorzy:
Witek, J.
Klecan, R.
Kleta, A.
Śliwa, A.
Powiązania:
https://bibliotekanauki.pl/articles/392480.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
przemysł energetyczny
materiał termoizolacyjny
izolacja ognioodporna
izolacja turbin
power industry
thermal insulating material
fireproof insulation
turbine insulation
Opis:
Opracowano nowe ognioodporne materiały termoizolacyjne wielokrotnego użycia, służące do izolacji cieplnej turbin i rurociągów pary przegrzanej w energetyce zawodowej. Wyroby te pozwalają zmienić technologię izolowania turbin i rurociągów pary przegrzanej, a w efekcie obniżyć koszty remontów, zdecydowanie poprawić warunki pracy ekip remontowych oraz wyeliminować problem powstawania, stwarzających duże zagrożenie ekologiczne, odpadów włóknistych.
New, fireproof insulation materials of the repeated use for thermal insulation of power station turbines and superheated steam pipelines were developed. This products allow to change the technology of turbines and superheated steam pipelines insulations and consequently to lower costs of repairs, improvement of repair teams working conditions and elimination the problem of generation of dangerous fibrous waste materials.
Źródło:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych; 2009, R. 2, nr 3, 3; 101-113
1899-3230
Pojawia się w:
Prace Instytutu Szkła, Ceramiki, Materiałów Ogniotrwałych i Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis and analytical simulation of the Rallis modified Stirling cycle
Autorzy:
Ranjan, Ravi Kant
Verma, Suresh Kant
Powiązania:
https://bibliotekanauki.pl/articles/240284.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
rallis modified Stirling cycle engine
nonisothermal characteristics
power output
thermal efficiency
charakterystyki nieizotermiczne
moc użyteczna
sprawność cieplna
Opis:
A Stirling cycle was developed by Rallis considering the adiabatic behaviour instead of isothermal behaviour of working fluid inside the expansion/compression volume, since the isothermal processes are very difficult to be realised in actual practice due to irreversibilities. In order to increase the performance of Rallis Stirling cycle engine, two modified versions of Rallis Stirling cycle engine model have been proposed and developed, called as Rallis modified Stirling cycle engine (RMSE). In this paper, the thermodynamic analysis of the developed models have been carried out and the simulated results are compared with the Rallis ideal model of Stirling cycle engine, as this model describes more accurately the thermodynamic cycle of practical Stirling machines. The results reveal the fact that the thermal efficiency of RMSE I model is enhanced by 38.06% and that of RMSE II model by 48.42%, whereas the power output is increased by 58.05% and 78.19% in case of RMSE I and RMSE II model respectively, when compared with the Rallis ideal adiabatic model of Stirling engine.
Źródło:
Archives of Thermodynamics; 2019, 40, 2; 35-67
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of thermal backfill parameters on current-carrying capacity of power cables installed in the ground
Autorzy:
Szultka, Seweryn
Czapp, Stanisław
Tomaszewski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/27311442.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
current-carrying capacity
numerical simulations
power cables
thermal analysis
obciążalność prądowa
analiza termiczna
symulacja numeryczna
kabel zasilający
Opis:
Proper design of power installations with the participation of power cables buried in homogeneous and thermally well-conductive ground does not constitute a major problem. The situation changes when the ground is non-homogeneous and thermally low-conductive. In such a situation, a thermal backfill near the cables is commonly used. The optimization of thermal backfill parameters to achieve the highest possible current-carrying capacity is insufficiently described in the standards. Therefore, numerical calculations based on computational fluid dynamics could prove helpful for designers of power cable lines. This paper studies the influence of dimensions and thermal resistivity of the thermal backfill and thermal resistivity of the native soil on the current-carrying capacity of power cables buried in the ground. Numerical calculations were performed with ANSYS Fluent. As a result of the research, proposals were made on how to determine the current-carrying capacity depending on the dimensions and thermal properties of the backfill. A proprietary mathematical function is presented which makes it possible to calculate the cable current-carrying capacity correction factor when the backfill is used. The research is expected to fill the gap in the current state of knowledge included in the provisions of standards.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2023, 71, 3; art. no. e145565
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System zacieniająco-izolujący - budowa, działanie, opłacalność
Shading/insulation system ? construction, performance, profitability
Autorzy:
Kęskiewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/402902.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
zużycie energii
bilans cieplny
aktywne zacienienia
termomodernizacja
nowoczesne budownictwo
power consumption
heat balance
modern construction
thermal efficiency improvement
Opis:
W pracy przedstawiono ideę systemu mającego przynosić oszczędności energii, poprzez ograniczanie przenikania ciepła przez przegrody przezroczyste. Oszczędności wynikają z okresowego zwiększenia izolacyjności przegród przezroczystych w okresie zimnym oraz z dodatkowego zacienienia pomieszczeń w okresie ciepłym. Przybliżono budowę i zasady działania systemu. Przedstawiono możliwości oraz różne parametry sterowania. Przedstawione zostały przewidywane korzyści i potencjalne zastosowania wynikające z zastosowania systemu. Wstępna, teoretyczna analiza ekonomiczna została oparta na zmodyfikowanej metodzie obliczania wskaźnika wartości zaktualizowanej netto, tzn. wskaźnika NPV. Uwzględniono zastosowania różnych źródeł i cen energii cieplnej oraz okresu zwrotu inwestycji. Analizę przedstawiono na przykładzie hali magazynowo-produkcyjnej zlokalizowanej w IV strefie klimatycznej. Symulacje przeprowadzono w programie Purmo OZC 4,0.
Presentation of shading/insulation system, which is supposed to reduce losses (gains) of energy through transparent surfaces. Periodic increase of insulation properties of transparent surfaces during winter period (lower heat loss) and additional protection against excessive sun exposure during warm days (lower demand on cooling energy) which will generate savings. Construction possibilities and operating principles and were shows. Ways to control system, as well as benefits and potential uses. Discussion of economic balance including usage of system, deferent sources of heat energy, theoretical money gains, and potential increase in heat energy costs. The economic balance sheet for an example of theoretical storage depot. Simulation performed on popular computer program Purmo OZC version 4,0.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 1; 51-56
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sprawność użytkowania systemu przygotowania ciepłej wody
Operating efficiency of hot water preparation systems
Autorzy:
Małecka, I.
Powiązania:
https://bibliotekanauki.pl/articles/407608.pdf
Data publikacji:
2011
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
wskaźniki zużycia ciepła
efektywność energetyczna
ciepła woda
węzeł ciepłowniczy
heat consumption meters
power efficiency
hot water
thermal centre
Opis:
Jedną z przyczyn powodującą wzrost zapotrzebowania energetycznego dla instalacji ciepłej wody jest wadliwa praca instalacji cyrkulacyjnej. Wskutek wadliwej pracy następuje zwiększenie strat wody wodociągowej i energii cieplnej czego przyczyną jest nadmierne "spuszczanie" ciepłej wody aż do momentu uzyskania przez odbiorcę wymaganej temperatury. Ma to miejsce szczególnie w godzinach nocnych, kiedy nie ma rozbioru ciepłej wody. W dzisiejszych czasach, gdzie głównie nacisk kładzie się na oszczędną pracę instalacji, należy poszukiwać energooszczędnych rozwiązań.
One of the reasons of increased power demand in hot water installations is defective performance of circulating systems. As a result of defective performance, more municipal water and thermal energy is wasted caused by letting hot water flow until the customer receives the desired temperature. This occurs particularly at night time when hot water is not consumed. At present, where the main emphasis is put on efficient system performance, more power-saving solutions have to be sought.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2011, 4; 96-100
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic rating method of traction network based on wind speed prediction
Autorzy:
Su, Zhaoux
Tian, Mingxing
Sun, Lijun
Zhang, Ruopeng
Powiązania:
https://bibliotekanauki.pl/articles/2086724.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dynamic thermal rating
IEEE-738
short-term emergency dispatch
time series model
traction power supply
wind speed prediction
Opis:
The operating temperature of the transmission line in the traction network is affected by geographical and climatic factors, especially the wind speed. To make better use of the thermal stability transmission capacity of the traction power supply system in improving the short-term emergency transmission capacity, the dynamic rating technology is introduced into the traction power supply system. According to the time-varying characteristics of the actual wind speed, a dynamic rating method of the traction network based on wind speed prediction is proposed and constructed. Based on the time series model in predicting the wind speed series along the corridor of the traction network, the temperature curve of each transmission line under different currents is calculated by combining it with the heat balance equation of an IEEE-738 capacity expansion model, thus the relationship between the peak operating temperature and current of each transmission line in the prediction period is obtained. According to the current distribution coefficient, the capacity increase limit of the traction network is determined. The example shows that the proposed dynamic rating method based on wind speed prediction is an effective method to predict the short-term safe capacity increase limit of the traction network, which can increase the comprehensive capacity of the traction network by about 45% in the next six hours, and the capacity increase effect is obvious, which can provide reference and technical support for short-term emergency dispatching of traction power supply dispatching centres.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 379--395
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An influence of fouling gathered on the heat transfer surfaces on the heat performance characteristics of the ship steam systems heat exchangers
Autorzy:
Hajduk, T.
Powiązania:
https://bibliotekanauki.pl/articles/1841551.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
marine power plant
gathering of fouling
heat transfer surface
heat performance characteristics
thermal resistance
heat trransfer
heat exchangers
Opis:
More than half of the incidents reported to EMSA relate to nautical events such as collision, groundings and contacts. Knowledge of accurate and high-integrity positioning is therefore not only a need for future automated shipping but a base for today’s safe navigation. Examples on accidents include Ever Given in the Suez Canal and HNoMS Helge Ingstad in Norway. A Network-RTK (NRTK) service can be used as an augmentation technique to improve performance of shipborne GNSS receivers for future positioning of manned and unmanned vessels in restricted areas, such as port areas, fairways, and inland water ways. NRTK service providers generate RTK corrections based on the observations of networks of GNSS reference stations which enables the users to determine their position with centimeter accuracy in real-time using a shipborne GNSS receiver. Selection of appropriate communication channels for dissemination of NRTK corrections data is the key to a secure positioning (localization) service. In PrePare-Ships project, the modern maritime communication system VDES (VHF Data Exchange System) is proposed to distribute SWEPOS (NRTK in Sweden) correction data to shipborne positioning modules. VDES is a very reliable technique and it is compatible with most onboard functionalities. In order to minimize the impact on the overall VDES data capacity in a local area, NRTK correction data shall only occupy a single VDES slot with a net capacity of 650 bytes. Update rates may vary but are preferably at 1Hz. However, NRTK correction data size changes instantly, depending on the number of visible GNSS satellites, and the data rate can therefore sometimes reach in excess of 1000 byte/s. In this study, a smart technique is proposed to reduce size of NRTK correction data to instantly adapt with the VDES requirements by choosing a combination of specific signals, satellites or even constellations such that the data rate is not more than 650 byte/s, and at the same time it achieves optimal positioning performance with the accuracy required by the PrePare-Ships project application.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2021, 15, 1; 183-189
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ degradacji urządzeń pomiarowych na pozyskiwanie symptomów niesprawnej pracy złożonych obiektów energetycznych
Influence of measuring equipment degradation on gaining of symptoms of large power units inefficient operation
Autorzy:
Głuch, J.
Powiązania:
https://bibliotekanauki.pl/articles/327488.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
symulacja neuronowa
diagnostyka cieplno-przepływowa
turbina parowa
neural simulation
thermal diagnostics
flow diagnostics
steam power plants
measuring system
Opis:
Opisywana jest możliwość budowania relacji cieplno-przepływowych diagnostycznych z zastosowaniem metody sztucznych sieci neuronowych. Są one zastosowane do detekcji zdegradowanych urządzeń pomiarowych w złożonych systemach pomiarowych. Przedstawiono to na przykładzie bloku energetycznego dużej mocy. Wykorzystano obliczenia symulacyjne degradacji. Rozważano zarówno degradacje samego systemu pomiarowego jak i degradacje geometrii urządzeń składowych. Pokazano dobrą jakość określania symptomów degradacji. Wykorzystano przykłady z praktyki eksploatacyjnej.
Possibility of building of diagnostic relations with usage of artificial neural networks ANN is described in the paper. The relations are applied for detection of the degraded measuring devices in steam power cycles of complex electricity generation systems. The example of the large steam turbine power plant is shown in the paper. Neuronal diagnostic relations are created on the basis of simulation calculations. There are taking into account both degradations of that of measuring equipment as well as simultaneously occurring degradations of measuring equipment and components of thermal cycle. Good quality of neuronal calculations is stated. Application of these relations is shown on some examples from exploitation practice.
Źródło:
Diagnostyka; 2008, 2(46); 67-70
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The design of a model for a 1 MW parabolic trough concentrated solar power plant in Sudan using TRNSYS software
Projekt modelu skoncentrowanej elektrowni słonecznej z rynną paraboliczną o mocy 1 MW w Sudanie z wykorzystaniem oprogramowania TRNSYS
Autorzy:
Jebreel, Abdelkareem Abdallah Abdelkareem
Hamad, Hamad Mohamed Ali
Powiązania:
https://bibliotekanauki.pl/articles/2127504.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
thermal storage
thermal solar collectors
photovoltaic solar panel
renewable source of energy
solar power plants
magazynowanie ciepła
termiczne kolektory słoneczne
fotowoltaiczne panele słoneczne
odnawialne źródła energii
elektrownie słoneczne
Opis:
Solar photovoltaic (PV) and concentrated solar power (CSP) systems are the present worldwide trends in utilizing solar energy for electricity generation. Solar energy produced from photovoltaic cells (PV) is considered the main common technology used due to its low capital cost; however, the relatively low efficiency of PV cells has spotlighted development and research on thermal engine applications using concentrated solar power. The efficiency of concentrated solar power is greater than that of PV and considering the solar potential for Sudan. Therefore, this study has been performed in an attempt to draw attention to the utilization of CSP in Sudan since the share of CSP is insignificant in comparison with PV, besides the suitability of CSP applications to Sudan’s hot climate and the high solar energy resource, the study presents a design model of 1 MW parabolic trough collectors (PTC) using the Rankine cycle with thermal energy storage (TES) in Sudan, by adopting reference values of the Gurgaon PTC power plant in India. The design of a 1 MW Concentrated Solar thermal power plant using parabolic trough collectors (PTC) and thermal energy storage is proposed. The simulation was performed for a site receiving an annual direct normal irradiance (DNI) of 1915 kWh/m2, near Khartoum. The results showed that the plant can produce between nearly 0.6 to 1 MWh during the year, and around 0.9 MWh when it encompasses thermal energy storage with an average thermal efficiency of 24%. These results of the PTC Power plant encourage further investigation and the development of CSP technologies for electricity generation in Sudan.
Systemy fotowoltaiczne (PV) i skoncentrowanej energii słonecznej (CSP) to obecne światowe trendy w wykorzystywaniu energii słonecznej do wytwarzania energii elektrycznej. Energia słoneczna wytwarzana z ogniw fotowoltaicznych (PV) jest uważana za główną powszechnie stosowaną technologię ze względu na jej niski koszt kapitałowy, jednak stosunkowo niska wydajność ogniw fotowoltaicznych zwróciła uwagę na rozwój i badania nad zastosowaniami silników cieplnych wykorzystujących skoncentrowaną energię słoneczną. W warunkach posiadanego potencjału słonecznego Sudanu wydajność skoncentrowanej energii słonecznej jest większa niż PV. Dlatego niniejsze badanie zostało przeprowadzone w celu zwrócenia uwagi na wykorzystanie CSP w Sudanie, ponieważ udział CSP jest nieznaczny w porównaniu z PV, pomimo przydatności zastosowań CSP do gorącego klimatu Sudanu i wysokich zasobów energii słonecznej. W pracy przedstawiono projekt modelu parabolicznych kolektorów rynnowych (PTC) o mocy 1 MW z wykorzystaniem cyklu Rankine’a z magazynowaniem energii cieplnej (TES) w Sudanie, przyjmując wartości referencyjne elektrowni Gurgaon PTC w Indiach. Zaproponowano projekt elektrowni słonecznej o mocy 1 MW wykorzystującej paraboliczne kolektory rynnowe (PTC) i magazynowanie energii cieplnej. Symulacja została przeprowadzona dla miejsca zlokalizowanego koło Chartumu, o rocznym bezpośrednim napromieniowaniu normalnym (DNI) 1915 kWh/m2. Wyniki pokazały, że elektrownia może wyprodukować od prawie 0,6 do 1 MWh w ciągu roku i około 0,9 MWh, przy wykorzystaniu magazynowanie energii cieplnej ze średnią sprawnością cieplną 24%. Te wyniki elektrowni PTC zachęcają do dalszych badań i rozwoju technologii CSP do wytwarzania energii elektrycznej w Sudanie.
Źródło:
Polityka Energetyczna; 2022, 25, 3; 67--90
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza parametrów otworów geotermalnych wykonanych na Niżu Polskim pod kątem możliwości budowy siłowni binarnych wykorzystujących ciepło wnętrza Ziemi
Analysis of parameters of geothermal well located on Polish Lowlands for the possibility of building the binary power plants which are using the heat from inside the earth
Autorzy:
Noga, B.
Biernat, H.
Kapuściński, J.
Martyka, P.
Powiązania:
https://bibliotekanauki.pl/articles/203419.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
geotermia
wody geotermalne
energia elektryczna
elektrownie binarne
Niż Polski
geothermal energy
thermal waters
electricity
binary power plants
Polish Lowland
Opis:
W pracy przedstawiono przegląd siłowni binarnych działających na świecie w warunkach zbliżonych do tych panujących na Niżu Polskim. Skupiono się głównie na tych, w których wykorzystywana jest woda termalna o temperaturze około 100°C. Przeanalizowano również parametry wody termalnej możliwej do pozyskania na Niż Polskim za pomocą już wykonanych otworów geotermalnych, w których wykonywane były pompowania pomiarowe.
This paper presents an overview of the binary power plants operating all over the world in the conditions similar to those prevailing in the Polish Lowlands. The paper is focused mainly on those power plants in which the thermal water’s temperature is around 100°C. The parameters of the thermal water possible to raise on the Polish Lowlands are also analyzed by using already completed geothermal wells, in which the pumping test were performed.
Źródło:
Technika Poszukiwań Geologicznych; 2013, R. 52, nr 2, 2; 127-139
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wybranych parametrów energetycznych modelowych silników prądu przemiennego małej mocy o różnych konstrukcjach wirnika
Evaluation of Selected Energy Performance of Low Power AC Motor with Different Rotor Structures
Autorzy:
Idziak, P.
Barański, M.
Łyskawiński, W
Kowalski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1368746.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny magnetoelektryczny
silnik indukcyjny
moc
sprawność
właściwości cieplne
permanent magnet synchronous motor
asynchronous motor
power
efficiency
thermal properties
Opis:
In the paper a power parameters of a line start permanent magnet synchronous motor (LSPMSM) and squirrel-cage motor have been compared. The stator of 3kW induction motor, Sg 100L-4B, was used In both structures. In order to determine opportunities to increase engine performance parameters of LSPMSM the heating curves of both motors were compared. It was found that even after the load LSPMSM increase of 20% over the induction motor rated torque, does not exceed the allowable operating temperature magnets. Efficiency, power factor and current in the stator windings obtained during measurements for both structures have been presented. Particular attention was paid to the possibility to obtain much greater output power for LSPMSM than for induction motor of the same size.
W artykule porównano parametry energetyczne dwóch silników: synchronicznego magnetoelektrycznego o rozruchu bezpośrednim (LSPMSM) oraz indukcyjnego klatkowego. W obu konstrukcjach wykorzystano stojan silnika indukcyjnego typu Sg 100L-4B o mocy 3 kW. W celu określenia możliwości polepszenia parametrów użytkowych silnika o magnesach trwałych porównano krzywe nagrzewania obu silników. Stwierdzono, że nawet wzrost momentu obciążenia LSPMSM o 20% ponad moment znamionowy silnika indukcyjnego, nie powoduje przekroczenia dopuszczalnej temperatury pracy magnesów. Dla obu konstrukcji zestawiono wyznaczone na podstawie pomiarów wartości: sprawności, współczynnika mocy i prądów silnika. Zbadano możliwość uzyskania znacznie większej mocy użytecznej silnika magnetoelektrycznego w stosunku do silnika indukcyjnego mającego te same gabaryty.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 53-57
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Paliwa pochodzące z odpadów – potencjał dla małych elektrociepłowni
Autorzy:
Latva-Somppi, Jouko
Ossera, Adam
Powiązania:
https://bibliotekanauki.pl/articles/1841872.pdf
Data publikacji:
2021
Wydawca:
Nowa Energia
Tematy:
termiczne przekształcanie odpadów komunalnych
paliwa z odpadów
elektrociepłownie
thermal treatment of municipal waste
fuel from waste
combined heat and power plants
Opis:
Udział energii słonecznej i wiatrowej w polskim systemie energetycznym ciągle rośnie, co powoduje zapotrzebowanie na całodobowe moce wytwórcze zapobiegające niestabilności sieci energetycznej. Dodatkowe wyzwanie stanowi konieczność zmniejszenia emisji CO2 poprzez odejście od węgla, jako podstawowego źródła energii pierwotnej. Rozwiązaniem dla polskich elektrociepłowni jest wykorzystanie paliw pochodzących z odpadów (RDF) i biomasy, których dostępność istotnie się zwiększyła w konsekwencji wprowadzonych uregulowań prawnych, dotyczących zagospodarowania odpadów.
Źródło:
Nowa Energia; 2021, 1; 11-13
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of optimisation methods applied to thermal cycle of a coal fired power plant
Autorzy:
Kowalczyk, Ł.
Elsner, W.
Powiązania:
https://bibliotekanauki.pl/articles/240829.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermodynamic optimisation
Nelder-Mead method
thermal cycle
coal fired power plant
IPSEpro
optymalizacja termodynamiczna
metoda Neldera-Meada
cykl termiczny
elektrownia węglowa
Opis:
The paper presents a thermodynamic optimization of 900 MW power unit for ultra-supercritical parameters, modified according to AD700 concept. The aim of the study was to verify two optimisation methods, i.e., the finding the minimum of a constrained nonlinear multivariable function (fmincon) and the Nelder-Mead method with their own constrain functions. The analysis was carried out using IPSEpro software combined with MAT-LAB, where gross power generation efficiency was chosen as the objective function. In comparison with the Nelder-Mead method it was shown that using fmincon function gives reasonable results and a significant reduction of computational time. Unfortunately, with the increased number of decision parameters, the benefit measured by the increase in efficiency is becoming smaller. An important drawback of fmincon method is also a lack of repeatability by using different starting points. The obtained results led to the conclusion, that the Nelder-Mead method is a better tool for optimisation of thermal cycles with a high degree of complexity like the coal-fired power unit.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 175-186
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wysokosprawnej mikro ko-generacji gazowej i gazowych pomp ciepła w modernizacji obiektu sportowo-rekreacyjnego
Utilization of high efficiency gas micro co-generation and gas heat pumps for renovation of the recreation and sports center
Autorzy:
Kaleta, P.
Wałek, T.
Powiązania:
https://bibliotekanauki.pl/articles/113215.pdf
Data publikacji:
2016
Wydawca:
STE GROUP
Tematy:
ciepło
energia elektryczna
MCHP XRGI
gazowe pompy ciepła GHP
korzyści ekonomiczne
thermal energy
electric power
gas heat pumps GHP
economic benefits
Opis:
W artykule przedstawiono analizę praktycznego zastosowania gazowych pomp ciepła i wysokosprawnej mikro ko-generacji gazowej w modernizowanym obiekcie sportowo-rekreacyjnym. Opisano zmiany dokonane w obiekcie, zapotrzebowanie na energie elektryczną i ciepło przed i po modernizacji oraz aspekty techniczne i ekonomiczne modernizacji obiektu.
In the article an analysis of implementation of gas heat pumps GHP and high efficient micro co-generation MCHP XRGI in renovation of the recreation and sport center is presented. Changes made to the center, energy demands before and after renovation as well as economic and technical aspects are described.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2016, 2 (14); 172-180
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena zużycia mediów po przeprowadzonej termomodernizacji
The assessment of media consumption after thermal modernization
Autorzy:
Ujma, A.
Lis, A.
Powiązania:
https://bibliotekanauki.pl/articles/2065360.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
termomodernizacja
zużycie wody
zużycie ciepła
zużycie prądu
zużycie gazu
koszt mediów
thermal modernization
water consumption
electric power consumption
gas consumption
utility costs
Opis:
Ochrona cieplna budynków i racjonalizacja zużycia mediów są bezpośrednio związane z oszczędnością energii, ale również z innymi aspektami. W artykule przedstawiono rzeczywiste rezultaty termomodernizacji na podstawie monitorowania jej efektów w czterech budynkach oświatowych. Analiza obejmuje zużycie wody, prądu, gazu i ciepła w tych budynkach. Zaobserwowano spadek zużycia mediów po termomodernizacji. Zanotowano znaczący spadek wskaźników zużycia mediów na jednego ucznia w ciągu roku w badanych szkołach.
The thermal protection of buildings and rationalization of water consumption are directly related with energy savings but also with other aspects. The article presents the real results of the thermal modernization activity based on the monitoring of their effects in four educational buildings. The analysis includes water, electricity and energy consumption of these buildings. It was found that after thermal modernization the reduction of the consumption of water, electricity and gas has been noticed. The significant decrease in rates of consumption of media attributed to one student, the learner in a year, in the analyzed schools has been registered.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2014, 2 (14); 103--110
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies