Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "probe" wg kryterium: Temat


Tytuł:
Probe radius correction methods - review and comparison of existing methods
Autorzy:
Rak, A.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/385250.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
coordinate measuring machine (CMM)
scanning probe
probe tip radius correction
Opis:
Scanning technology has been becoming more common then ever. Scanning offers new and effective possibilities of measurement. Nowadays planning, production and assembling without high accurate metrology is impossible. Measurement of small, curved elements became much easier with great development of mechanical components of measure machines, such as: guideways, transducers, bearings, servomechanisms. All this improvement made possible to collect with good accuracy points in high density. Algorithms, and computer software were greatly improved as well. Especially, many efforts were put on probe radius correction algorithms development. In this paper a review and a comparison of probe radius correction methods are shown.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 169-171
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of magnetized low temperature plasma by ball - pen probe
Autorzy:
Adámek, J.
Peterka, M.
Gyergyek, T.
Kudrna, P.
Tichý, M.
Powiązania:
https://bibliotekanauki.pl/articles/146432.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ball-pen probe
magnetron
Opis:
The ball-pen probe is an innovative electric probe for direct measurements of the plasma potential in magnetized hot plasma. This probe is based on the Katsumata probe concept. The ball-pen probe can adjust the ratio I- saturat/I+ saturat of the electron and ion saturation currents to be equal to one and therefore the ball-pen probe characterization becomes symmetric. If this is achieved, the floating potential of the ball-pen probe is equal to the plasma potential in Maxwellian plasma. We show the application of a ball-pen probe in slightly magnetized low temperature plasma.
Źródło:
Nukleonika; 2012, 57, 2; 297-300
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ARMScope – the versatile platform for scanning probe microscopy systems
Autorzy:
Świadkowski, Bartosz
Piasecki, Tomasz
Rudek, Maciej
Świątkowski, Michał
Gajewski, Krzysztof
Majstrzyk, Wojciech
Babij, Michał
Dzierka, Andrzej
Gotszalk, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/221551.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Scanning probe microscopy
AFM
Kelvin Probe force microscopy
scanning tunnelling microscopy
Opis:
Scanning probe microscopy (SPM) since its invention in the 80’s became very popular in examination of many different sample parameters, both in university and industry. This was the effect of bringing this technology closer to the operator. Although the ease of use opened a possibility for measurements without high labour requirement, a quantitative analysis is still a limitation in Scanning Probe Microscopes available on the market. Based on experience of Nano-metrology Group, SPM still can be considered as a tool for quantitative examination of thermal, electrical and mechanical surface parameters. In this work we present an ARMScope platform as a versatile SPM controller that is proved to be useful in a variety of applications: from atomic-resolution STM (Scanning Tunnelling Microscopy) to Multi-resonance KPFM (Kelvin Probe force microscopy) to commercial SEMs (Scanning electron microscopes).
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 119-130
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tilt-shift eddy current probe impact on information value of response signal
Autorzy:
Chudacik, V.
Smetana, M.
Powiązania:
https://bibliotekanauki.pl/articles/140578.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy current testing
eddy current probe
response signals
tilt-shift probe
Opis:
This article deals with the possibility for increasing of the informational value of a response signal using tilt-shift eddy current probe. Numerical simulations based on the FEM method using the OPERA 3D software as well as gained experimental results are presented. The simulated cracks are evaluated at the selected eddy current probe tilts and shifts with respect to conductive plate to obtain additional data needed for its evaluation and localization. Obtained simulation results are compared and discussed with the experimental results.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 133-140
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermionic vacuum arc diagnostic using emissive probe
Autorzy:
Tiron, V.
Aniculaesei, C.
Popa, G.
Powiązania:
https://bibliotekanauki.pl/articles/385290.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
thermionic vacuum arc
emissive probe
Opis:
In this paper, experimental results are presented on study of the copper thermionic vacuum arc using emissive probe. Experimental results show that plasma potential is direct related to the discharge voltage and it shows nonlinear distribution from the anodic melted spot towards to the plasma extremity.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 147-149
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of micro- and nanostructure using the scanning probe microscopy
Autorzy:
Gotszalk, T.
Janusz, P.
Marendziak, A.
Czarnecki, P.
Radojewski, J.
Szeloch, R. F.
Grabiec, P.
Rangelow, I. W.
Powiązania:
https://bibliotekanauki.pl/articles/308801.pdf
Data publikacji:
2005
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
scannig probe microscopy
microsystem
nanofabrication
Opis:
In this paper we summarize the results of our research concerning the diagnostics of micro- and nanostructure with scanning probe microscopy (SPM). We describe the experiments performed with one of the scanning probe microscopy techniques enabling also insulating surfaces to be investigated, i.e., atomic force microscopy (AFM). We present the results of topography measurements using both contact and non-contact AFM modes, investigations of the friction forces that appear between the microtip and the surface, and experiments connected with the thermal behaviour of integrated circuits, carried out with the local resolution of 20 nm.
Źródło:
Journal of Telecommunications and Information Technology; 2005, 1; 41-46
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A coumarin-based fluorescent probe for specific and rapid detection of fluoride ions
Autorzy:
Xin, Z.-H.
Meng, Y.-L.
Wu, Y.-H.
Feng, Z.-K.
Kang, Y.-F.
Powiązania:
https://bibliotekanauki.pl/articles/778907.pdf
Data publikacji:
2018
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Fluorion
Fluorescence
Coumarin
Probe
Bioimaging
Opis:
A simple and coumarin-based fluorescence probe has been designed and synthesized with silyl group as recognition group of fluoride ions (F−) in this study. The results showed that the fluorescence intensity of the probe displayed prominent enhancement with addition of F− at 445 nm with incubation of 1 min. There was an excellent linear relationship between fluorescence intensity and fluoride concentration from 0 to 30 μM (0~0.57 ppm), which offered the important condition for the quantitative analysis. In addition, the highly selective response to fluorion, the low detection limit with 28 nM (0.532 ppb), low toxicity and bioimaging afforded an advantage for practical application and detecting fluoride in biological systerms.
Źródło:
Polish Journal of Chemical Technology; 2018, 20, 4; 1-5
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of the measurement method of relative moisture determination using Peltier probe
Modyfikacja techniki pomiarowej do wyznaczania wilgotności względnej za pomocą sondy psychrometrycznej Peltiera
Autorzy:
Guz, Ł.
Suchorab, Z.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/127061.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
psychrometric probe
sleeves
sondy psychrometryczne
tuleje
Opis:
Psychrometric probes are used for porous materials potential determination which can be easily recalculated into the relative moisture. They can be also applied for building materials moisture parameters determination. They enable relative moisture readout in the narrow range between 94 and 99.9%. Water film evaporating from the thermocouple causes temperature decrease and generation of a voltage in a range of microvolts. Due to external heat flux influence on the applied sensors (Wescor PST-55 probes) the measurement must be conducted in the stabilized conditions. Non-stable heat flows and thus the decrease of measurement results repeatability. This is especially important during measurement of porous material samples with small dimensions. To increase the measurement accuracy the probes were equipped with metal sleeves having the external diameter of 12 mm and wall thickness 1 mm. The aim of the sleeve is to stabilize the instantaneous temperature variations and bridge the heat flow around the psychrometric Peltier probe.
Sondy psychrometryczne służą do pomiaru potencjału wody materiałów porowatych, którą można przeliczyć na wilgotność względną. Stosowane są od lat w agrotechnice i mogą również być zastosowane do pomiarów parametrów wilgotnościowych materiałów budowlanych. Umożliwiają odczyt wilgotności względnej w wąskim zakresie około 94÷99,9%. Jest to możliwe dzięki zjawisku Seebecka, odparowujący film wody z termopary powoduje obniżenie jej temperatury i wygenerowanie mikrowoltowego napięcia. Z uwagi na niską wartość mikrowoltowego napięcia generowanego na sondach Wescor PST-55, użytych podczas badań, pomiary muszą odbywać się w ustabilizowanych warunkach. Nieustabilizowane przepływy strumienia ciepła lub skoki temperatury powodują zmniejszenie powtarzalności wyników pomiarów. Ma to szczególne znaczenie podczas pomiarów próbek materiałów porowatych o niewielkich wymiarach geometrycznych. W celu zwiększenia dokładności pomiarów sondy zostały osłonięte metalowymi tulejami o średnicy 10 mm i grubości ścianki 1 mm. Zadaniem takiej tulei jest stabilizowanie nagłych wahań temperatury i regulowanie przepływów strumienia ciepła wokół sondy psychrometrycznej Peltiera.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 51-56
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of plasma diffusion coefficient in Pilot-PSI device using Katsumata probe
Autorzy:
Solomon, M. L.
Mihaila, I.
Anita, V.
Costin, C.
Popa, G.
van der Meiden, H.
Al, R.
van Rooij, G.
Cardozo, N. L.
Rapp, J.
Ionita, C.
Stärz, R.
Schrittwieser, R.
Powiązania:
https://bibliotekanauki.pl/articles/385269.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Katsumata probe
magnetized plasma
diffusion coefficient
Opis:
Cross-field transport of particles and energy is a major issue in magnetized fusion-relevant plasmas, due to its relevance for plasma confinement. In this paper Katsumata probe measurements performed in Pilot-PSI linear magnetized plasma device are presented. The plasma diffusion coefficient in perpendicular direction to the magnetic field was estimated from the measurements.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 160-162
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the impact of probe head hysteresis on the accuracy of five-axis coordinate measuring systems
Autorzy:
Gąska, P.
Gruza, M.
Gąska, A.
Harmatys, W.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102633.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
hysteresis
accuracy
CMM
Opis:
One of the factors affecting the accuracy of Coordinate Measuring Systems is hysteresis of a probe head. It is important especially in case of touch trigger probes and should be taken into account during the determination of probing strategy. In this article, the authors try to assess how this phenomenon affects the accuracy of five axis coordinate systems which utilize articulating probe head. Such systems allow to measure point coordinates using rotary movements of the head what introduces changes to the probing process. The experiments presented in this paper are based on multiple measurements of the reference elements such as gauge blocks and standard ring.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 277-282
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impedance measurements problem in antennas for RFID technique
Autorzy:
Jankowski-Mihułowicz, P.
Pitera, G.
Węglarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/221609.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
RFID
antenna
impedance measurement
differential probe
Opis:
The authors paid particular attention to the problem of antenna impedance measurements in the RFID technique. These measurements have to be realized by using two ports of a vector network analyzer and dedicated passive differential probes. Since the measurement process and estimated parameters depend on the frequency band, operating conditions, type of the system component and antenna designs used, appropriate verification of the impedance parameters on the basis of properly conducted experiments is a crucial stage in the antenna synthesis of transponders and read/write devices. Accordingly, a systematized procedure of impedance measurements is proposed. It can be easily implemented by designers preparing antennas for different kinds of RFID applications. The essence of indirect measurements of the differential impedance parameters is discussed in details. The experimental verification has been made on the basis of a few representative examples.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 509-520
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a carbazole derivative as a spectroscopic fluorescent probe for real time monitoring of cationic photopolymerization
Autorzy:
Ortyl, J.
Galica, M.
Popielarz, R.
Bogdał, D.
Powiązania:
https://bibliotekanauki.pl/articles/778445.pdf
Data publikacji:
2014
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
spectroscopic fluorescent probe
FPT
fluorescence
carbazole
photopolymerization
Opis:
The performance of 1-(9-ethylcarbazol-3-yl)-4,4,4-trifluorobutane-1,3-dione (1) as a fluorescent probe for the monitoring of cationic photopolymerization processes by Fluorescence Probe Technique (FPT) has been evaluated in comparison with the response of 7-diethylamino-4-methylcoumarin (Coumarin 1) (2). Triethylene glycol divinyl ether and diphenyliodonium hexafluorophosphate were used as an example monomer and a cationic photoinitiator respectively. It has been found that the probe 1 withstands the cationic polymerization conditions and provides correct probe response. 1-(9-ethylcarbazol-3-yl)-4,4,4-trifluorobutane-1,3-dione shifts its fluorescence spectrum with progress of cationic photopolymerization of the monomer, which enables the monitoring of the polymerization progress using the fluorescence intensity ratio measured at two different wavelengths as the progress indicator. By comparing the behavior of 1 and 2, it has been documented that the fluorescence spectrum of probe 1 shows a spectacular hypsochromic shift (Δλ = 33 nm) upon the monomer polymerization, while the shift of 2 is three times smaller (Δλ = 11 nm). Moreover, the sensitivity of probe 1 is more than 2.5-times higher than that of any other probes suitable for monitoring cationic polymerization processes, reported previously. Therefore, application of the carbazole derivative (1) as a new probe for the monitoring of the crosslinking process of coatings cured by cationic photopolymerization has been proposed.
Źródło:
Polish Journal of Chemical Technology; 2014, 16, 1; 75-80
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Employing Optical Measurements for Monitoring and Diagnostics of Combustion Process in Industrial Conditions
Autorzy:
Wójcik, W.
Suleimenov, B.
Junisbekov, M.
Kalizhanova, A.
Smailova, S.
Mussabekov, R.
Powiązania:
https://bibliotekanauki.pl/articles/124530.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
combustion process
fiber optic probe
signal analysis
Opis:
The paper discusses some practical problems conected with introdction of modern coal combustion technologies as well as biomass co-combustion. In order to ensure that the combustion process runs in a proper way, the multichannel fiber optic monitoring system was applied. The system converts the optical signals coming from several flame zones to electrical that were further transmitted to the control room. The article prsents signal analyses made in time-frequency domain using short-time Fourier transform and wavelet transform and the way of their visualization to power boiler operators.
Źródło:
Journal of Ecological Engineering; 2017, 18, 1; 273-283
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie krzywej retencji wody materiałów porowatych za pomocą sond psychometrycznych i TDR
Determination of the water retention curves for porous materials using psychrometric probes combined with TDR methodology
Autorzy:
Guz, Ł.
Suchorab, Z.
Alcobia, B.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/126951.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
psychrometria
sonda TDR
krzywa retencji
materiały porowate
psychrometric probe
TDR probe
soil water retention curve
porous materials
Opis:
Woda jest bardzo ważnym składnikiem produkcji materiałów budowlanych. Jest również jednym z najbardziej destruktywnych czynników podczas późniejszej eksploatacji obiektów z nich zbudowanych. Z tego względu niezbędna jest znajomość właściwości wilgotnościowych materiałów, takich jak: podsiąkanie kapilarne, opór dyfuzyjny czy nasiąkliwość. Właściwości materiałów porowatych związanych z wilgotnością bardzo dobrze opisuje krzywa retencji wody. Określa ona, jaką ilość wody materiał porowaty jest w stanie wchłonąć oraz z jaką siłą utrzymuje wodę w przestrzeniach porowatych. Jest to zależność pomiędzy ciśnieniem ssącym wodę a zawartością wody. W niniejszej pracy przedstawiono krzywe retencji wody wyznaczone dla gazobetonu o gęstości 450; 550 i 650 kg/m3. Krzywa została wyznaczona poprzez sprzężenie dwóch technik pomiarowych: psychrometrycznej i reflektometrycznej TDR. Ciśnienie ssące było zmierzone za pomocą sond psychrometrycznych Peltiera, a wilgotność objętościowa poprzez sondy TDR. Krzywa retencji opisana w publikacji została wyznaczona tylko w wąskim zakresie, determinowanym czułością sond psychrometrycznych, który mieścił się w granicach od 0,03 do 0,12 m3/m3 wilgotności objętościowej materiału porowatego.
Water is an important compound of building materials production technology. On the other hand it is one of the most destructive factor during exploitation of building objects. That is why it is necessary to know the moisture parameters of the materials like porosity, maximum water content, capillary rise and water conductivity. Water parameters of the porous materials can be described by water retention curve, which valuates what amount of water can be absorbed by the material and what force remains water in air gaps. It is dependence between water potential and moisture. In this work there are presented water retention curves determined for aerated concrete with the apparent density of 450, 550 and 650 kg/m3. Determination of water retention curve was achieved by combination of two measuring techniques: Peltier psychrometric probes for water potential and TDR for water content. Water retention curve described in the paper was established only in a small range of moisture which is mainly caused by the sensitivity of the psychrometric probes, which value was varying in the frames of material moisture between 0.03 and 0.12 m3/m3.
Źródło:
Proceedings of ECOpole; 2010, 4, 2; 371-375
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seebeck coefficient measurement by Kelvin-probe force microscopy
Autorzy:
Ikeda, H.
Salleh, F.
Asai, K.
Powiązania:
https://bibliotekanauki.pl/articles/384281.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Seebeck coefficient
Kelvin-probe force microscopy
nanostructure
Opis:
In order to measure the Seebeck coefficient of nanometer-scale thermoelectric materials, we propose a new technique in which the thermoelectric-motive force (TEMF) is evaluated by Kelvin-probe force microscopy (KFM). In this study, we measured the Seebeck coefficient of an n-type Si wafer. The surface-potential difference between the high- and low-temperature regions on the Si wafer increases with increasing temperature difference. This indicates that the TEMF can be measured by KFM. The Seebeck coefficient evaluated from the surface-potential difference is 0.71š0.08 mV/K, which is close to that obtained by the conventional method.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 49-51
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A near-infrared fluorescent probe for selective detection of fluorion
Autorzy:
Kang, Yan-Fei
Wei, Fan
Meng, Ya-Li
Xin, Zhen-Hui
Wei, Dong
Powiązania:
https://bibliotekanauki.pl/articles/778367.pdf
Data publikacji:
2020
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Probe
Fluorescence
Fluoride anion
Selectivity
Near-infrared
Opis:
In this work, we have designed and synthesized the fluorescent probe 1, which was capable to selectively detect fluoride anion (F). More importantly, the probe 1 possessed near-infrared excitation and emission wavelengths (excitation at 650 nm and emission at 695), and the probe solution had changed dramatically from yellow to cyan with the addition of F. In addition, the fluorescence intensity exhibited perfectly positive correlation with concentration of F concentration from 0 to 40 μM (R2 = 0.9972), which offered the important condition for quantitative analysis. The probe 1 owned detection limit of 46 nM. Therefore, this near-infrared probe can be of great benefit for detecting F in practical application.
Źródło:
Polish Journal of Chemical Technology; 2020, 22, 1; 1-5
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A characterization of 2-tree probe interval graphs
Autorzy:
Brown, David E.
Flesch, Breeann M.
Lundgren, J. Richard
Powiązania:
https://bibliotekanauki.pl/articles/30148257.pdf
Data publikacji:
2014-08-01
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
interval graph
probe interval graph
2-tree
Opis:
A graph is a probe interval graph if its vertices correspond to some set of intervals of the real line and can be partitioned into sets P and N so that vertices are adjacent if and only if their corresponding intervals intersect and at least one belongs to P. We characterize the 2-trees which are probe interval graphs and extend a list of forbidden induced subgraphs for such graphs created by Pržulj and Corneil in [2-tree probe interval graphs have a large obstruction set, Discrete Appl. Math. 150 (2005) 216-231]
Źródło:
Discussiones Mathematicae Graph Theory; 2014, 34, 3; 509-527
2083-5892
Pojawia się w:
Discussiones Mathematicae Graph Theory
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interstellar probe: science, engineering, logistic, economic, and social factors
Autorzy:
Ratkiewicz, Romana
Baraniecka, Anna
Stępniewski, Kajetan
Miś, Tomasz
Błądek, Piotr
Tkacz, Arkadiusz
Mikołajków, Tomasz
Kozanecki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/27314483.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Centrum Badań Kosmicznych PAN
Tematy:
Interstellar Probe mission
science
engineering
logistic
business
Opis:
In this publication, we refer to a certain novelty introduced to the presentation at the AGU 2020 conference. This novelty consists of quoting the thoughts, remarks, and comments of six young people who declared their interest in space research after listening to a lecture on the Interstellar Probe journey, organized in June 2020 by the Polish Space Agency. Therefore, they were then asked to express their comments after reading two publications on the Interstellar Probe that were sent to them. As a result, this idea also became the topic of this article. Although the interstellar mission is primarily a research and science project, its engineering, logistics, business (economic), and social aspects, as well as a short commentary on our home in the universe, which is the heliosphere, have also been included in this article.
Źródło:
Artificial Satellites. Journal of Planetary Geodesy; 2023, 58, 2; 29--41
2083-6104
Pojawia się w:
Artificial Satellites. Journal of Planetary Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie sondy CPTU 15 cm2 do badań podłoża gruntowego
The use of 15 cm2 CPTU for investigations of subsoil
Autorzy:
Bajda, M.
Biliniak, M.
Lech, M.
Powiązania:
https://bibliotekanauki.pl/articles/40404.pdf
Data publikacji:
2012
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
geotechnika
grunty
badania terenowe
sondowanie statyczne
sonda CPTU
wykorzystanie
geotechnics
soil
field research
static sounding
CPTU probe
probe use
Źródło:
Acta Scientiarum Polonorum. Architectura; 2012, 11, 2
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy związane z korekcją promienia końcówki pomiarowej podczas skaningowych pomiarów współrzędnościowych
Difficulties with the corrected measured point determination in coordinate metrology
Autorzy:
Woźniak, A.
Mayer, M.
Cote, M.
Powiązania:
https://bibliotekanauki.pl/articles/153572.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Współrzędnościowa Maszyna Pomiarowa
WMP
sonda głowica skaningowa
korekcja promienia końcówki
Coordinate Measuring Machine
CMM
scanning probe
probe radius compensation
Opis:
W artykule przedstawiono analizy teoretyczne i badania doświadczalne potwierdzające, że korekcja promienia końcówki pomiarowej może być istotnym źródłem błędów podczas saningowych pomiarów przeprowadzanych na maszynach współrzędnościowych. Przedstawiono wyniki pomiarów przykładowego elementu na maszynie Mitutoyo LEGEX 910 CMM wyposażonej w sondę skaningową MPP-300, ze wskazaniem mechanizmów złej korekcji promienia końcówki pomiarowej.
Paper discusses an understanding for the compensation of the probe ball radius in a scanning process carried out by coordinate measuring machines (CMM). According to some initial trials of scanning measurement using the stylus tip radius correction built-in the CMM software, it was found, as will be shown in the paper, that the indigenous CMM software do not compensate the stylus tip radius well. As a result, the information about the real shape of the measured reatures can be distored. The difficulties with the corrected measured point determination will be demonstrate no the basis of tests were carried out on a Mitutoyo LEGEX 910 CMM equipped with a MPP-300 scanning probe.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 485-488
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
Powtarzalność i odtwarzalność pomiarów lokalizacji taśmy podcewkowej uzyskanych w USG dna miednicy wykonywanym głowicą przezpochwową
Autorzy:
Dresler, Maria Magdalena
Kociszewski, Jacek
Wlaźlak, Edyta
Pędraszewski, Piotr
Trzeciak, Agnieszka
Surkont, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1033435.pdf
Data publikacji:
2017
Wydawca:
Medical Communications
Tematy:
pelvic ultrasound
repeatability
suburethral tape
transvaginal probe
urogynecology
Opis:
Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.
Wstęp: Implanty stosowane do leczenia pacjentek z dolegliwościami uroginekologicznymi są dobrze widoczne w badaniu ultrasonograficznym. Lokalizacja taśmy podcewkowej określana jest w stosunku do cewki moczowej oraz spojenia łonowego. Cel pracy: Celem pracy była ocena dokładności pomiarów określających lokalizację taśmy podcewkowej uzyskanych podczas badania ultrasonograficznego dna miednicy wykonywanego głowicą przezpochwową. Materiał i metody: Analizą objęto wyniki pomiarów ultrasonograficznych przeprowadzonych zgodnie z wystandaryzowaną techniką u kobiet, które zostały skierowane na diagnostykę uroginekologiczną. Do analizy powtarzalności i odtwarzalności wyników uzyskanych tego samego dnia wykorzystano dane od 68 pacjentek. Wyniki: Współczynnik korelacji wewnątrzklasowej dla powtarzalności oraz odtwarzalności pomiarów lokalizacji taśmy podcewkowej uzyskanych w badaniu ultrasonograficznym głowicą przezpochwową wahał się od 0,6665 do 0,9911. Analiza pomiarów lokalizacji taśmy podcewkowej potwierdziła ich zgodność na bardzo dobrym i dobrym poziomie. Wnioski: Bardzo dobra i dobra powtarzalność oraz odtwarzalność pomiarów lokalizacji taśmy podcewkowej uzyskanych w badaniu ultrasonograficznym dna miednicy wykonywanym głowicą przezpochwową stanowią potwierdzenie możliwości zastosowania tego badania w praktyce klinicznej i w badaniach naukowych. Artykuł w wersji polskojęzycznej jest dostępny na stronie http://jultrason.pl/index.php/wydawnictwa/volume-17-no-69
Źródło:
Journal of Ultrasonography; 2017, 17, 69; 101-105
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of measured workpiece’s form errors influence on the accuracy of probe heads used on five-axis measuring systems
Autorzy:
Harmatys, W.
Gąska, A.
Gruza, M.
Gąska, P.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102182.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
five-axis system
accuracy
CMM
Opis:
The five-axis measuring systems are one of the most modern inventions in coordinate measuring technique. They are capable of performing measurements using only the rotary pairs present in their kinematic structure. This possibility is very useful because it may cause significant reduction of total measurement time and costs. However, it was noted that high values of measured workpiece’s form errors may cause significant reduction of the accuracy of a five-axis measuring system. The investigation on the relation between these two parameters was conducted in this paper and possible reasons of decrease in measurement accuracy was discussed on the example of measurements of workpieces with form errors ranging from 0,5 to 1,7 millimetre.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 305-310
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of multiple velocity and temperature probe sets for ventilated spaces
Autorzy:
Alimardani, R.
Hoff, S.J.
Powiązania:
https://bibliotekanauki.pl/articles/24933.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
temperature measurement
temperature
ventilation
probe
development
thermistor
velocity
Źródło:
International Agrophysics; 2005, 19, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Sensitivity Field of Dual Transducer Probes on Accuracy of Discontinuity Sizing and Evaluation in Terms of Testing of Forgings According to EN 10228-3
Autorzy:
Kaczmarek, R.
Kaczmarek, K.
Powiązania:
https://bibliotekanauki.pl/articles/352659.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
non destructive testing
ultrasonic testing
double transducer probe
Opis:
The article presents results of research on the impact of sensitivity distribution of double transducer probes, which are often used in non-destructive ultrasonic testing of components such as forgings. Distribution of sensitivity measured in two orientations, parallel and perpendicular to the plane of separation of a double transducer probe has been tested and analyzed. A significant influence of orientation of a probe on echo envelope of an artificial point discontinuity has been studied. It has revealed great differences in length and shape of an echo envelope, depending on a type of probe and orientation of a probe separation plane to the moving direction. Eventually, the analysis of practical consequences of dual transducer probes usage for characterization of a type, dimensioning and evaluation of internal discontinuities, in accordance to the methodology specified in EN 10228, has been conducted.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1677-1682
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensation of systematic errors of damaged probe for on-machine measurement
Autorzy:
Wozniak, A.
Jankowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/99611.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
on-machine measurement
touch trigger probe
errors compensation
Opis:
Spatial characteristic of triggering radius of the damaged probe for the CNC machine tools has been presented. In such case a clear distortion of the probe performance characteristic and a significant increase in probe errors have been observed. Then, to such a damaged probe, a variable speed correction method of systematic errors was used. By setting proper measurement speeds, varying for different measurement directions, errors of the probe can be significantly reduced.
Źródło:
Journal of Machine Engineering; 2018, 18, 1; 88-94
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vibro piles performance prediction using result of CPT
Autorzy:
Więcławski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2037706.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Vibro piles
ultimate capacity
settlement curve
CPT probe
Opis:
Vibro piles belong to the group of full displacement piles with an expanded base, characterised by a very high load capacity, especially in non-cohesive soils. The problem is to adopt a reliable method for the determination of full load-settlement (Q-s) curve. A frequent difficulty is the determination of the load capacity limit based on the static load test because the course of the load-settlement curve is of a linear nature. This publication presents the empirical method. It allows direct prediction of a full axially loaded pile settlement curve based on the values of qc cone resistance obtained in cone penetration test (CPT). The advantage offered by this procedure is the accuracy of the obtained limit values in relation to the actual load-bearing capacity as compared to other methods based on soil parameters obtained in in situ testing. An additional advantage is the Q-s characteristics, which enable designing for intermediate values, allowing for the criterion of minimal or equal settlements. The shape of analytical curves was compared with static pile load test (SPLT) curves. This comparison showed large convergences between the analytical and measured curves.
Źródło:
Studia Geotechnica et Mechanica; 2021, 43, 4; 452-464
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
(Brak) kontroli jakości urządzeń ultrasonograficznych
(Lack of) quality control of ultrasound devices
Autorzy:
Jędrzejewska, Monika
Węckowski, Bartosz
Jankowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2146813.pdf
Data publikacji:
2021
Wydawca:
Indygo Zahir Media
Tematy:
ultrasonografia
kontrola jakości
sonda
ultrasonography
quality control
probe
Opis:
Kontrola jakości aparatury ultrasonograficznej budzi wiele kontrowersji. W Polsce opiera się ona na błędnym założeniu, że ultrasonografia jest nieszkodliwa, nie powinna zatem podlegać takiej kontroli jak metody diagnostyczne bazujące na promieniowaniu jonizującym. Powyższe nie eliminuje jednak potrzeby prowadzenia testów kontroli jakości. Kryterium braku szkodliwości nie zmienia faktu, że nieprawidłowe funkcjonowanie systemu obrazowania może stanowić zagrożenie dla zdrowia i życia pacjentów ze względu na błędną diagnozę. W artykule zaproponowano schemat postępowania w zakresie oceny ultrasonografów, sond, protokołu pomiarowego oraz uzyskanych wyników i weryfikacji poprawności rejestracji obrazu.
The quality control of the ultrasound equipment is controversial. In Poland, it is based on the erroneous assumption that ultrasonography is harmless, therefore it should not be subject to such control as diagnostic methods based on ionizing radiation. However, the above does not eliminate the need to conduct quality control tests. The non-harmfulness criterion does not change the fact that improper functioning of the imaging system may pose a threat to the health and life of patients due to incorrect diagnosis. The article proposes a procedure for the assessment of ultrasound scanners, probes, measurement protocol, the obtained results and verification of the correctness of image registration.
Źródło:
Inżynier i Fizyk Medyczny; 2021, 10, 1; 69--75
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Urządzenie do lokalizacji sensorów pomiarowych w sondach temperatury wykorzystywane do precyzyjnego wyznaczania SND w konserwie
A device for locating measuring sensors in temperature probes used for precise determination of SHZ in cans
Autorzy:
Szczepka, Maciej
Stasiak, Alicja
Czyżewski, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/270989.pdf
Data publikacji:
2019
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
strefa najmniejszego dogrzania
sonda temperatury
wielokanałowa sonda temperatury
czujnik temperatury
slowest heating zone
temperature probe
multi-channel temperature probe
temperature sensor
Opis:
Artykuł opisuje przyrząd pomiarowy służący do precyzyjnego lokalizowania czujników temperatury w obudowach sond temperatury. Opis dotyczy budowy urządzenia oraz metody pomiarowej.
The article describes a measuring instrument used for precise location of temperature sensors in temperature probe casings. The description concerns the construction of the device and the measurement method.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2019, 24, 3; 193-196
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary laboratory tests of a new fibre optic high temperature measurement device
Autorzy:
Lisiecka, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/173508.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
non-contact thermometer
high temperature measurements
fibre optic probe
Opis:
This article presents the laboratory verification of the author’s algorithm for temperature determination. The conducted tests confirm the ability to eliminate the measurement condition impact (emissivity of the radiation source, attenuation of the atmosphere) on non-contact thermometric measurement results. What is more, this method allows measurement for wavelength shorter than 1 µm to be carried out. The second stage of the work involved transmission tests of the fibre optic probe. The use of three quartz rods ensured that thermal radiation from each direction in a perpendicular plane to the probe head is collected and transmitted. The combination of the new temperature determination method and new constructed measurement instrument will allow the area of application of a non-contact thermometric device to be extended.
Źródło:
Optica Applicata; 2019, 49, 4; 669-677
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement uncertainty analysis of different CNC machine tools measurement systems
Autorzy:
Semotiuk, L.
Józwik, J.
Kuric, I.
Powiązania:
https://bibliotekanauki.pl/articles/102390.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
measurement uncertainty
inspection probe
control system
CNC machine tool
Opis:
In this paper the results of measurement uncertainty tests conducted with a Heidenhain TS 649 probe on CNC machine tools are presented. In addition, identification and analysis of random and systematic errors of measurement were presented. Analyses were performed on the basis of measurements taken on two different CNC machine tools with Heidenhain control system. The evaluated errors were discussed and compensation procedures were proposed. The obtained results were described in tables and figures.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 19; 41-47
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The dynamics of the surface layer of lipid membranes doped by vanadium complex : computer modeling and EPR studies
Autorzy:
Olchawa, R.
Man, D.
Pytel, B.
Powiązania:
https://bibliotekanauki.pl/articles/147585.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
EPR probe
lipid membrane
membrane fluidity
Monte Carlo simulation
Opis:
Penetration of the liposome membranes doped with vanadium complex formed in the liquid-crystalline phase from egg yolk lecithin (EYL) by the TEMPO (2,2,6,6-tetramethylpiperidine-1-oxyl) spin probes has been investigated. The penetration process was followed by 360 hours at 24◦C, using the electron spin resonance (EPR) method. The spectroscopic parameter of the partition (F) of this probe indicated that a maximum rigidity of the membrane was at 3% concentration of the vanadium complex. Computer simulations showed that the increase in the rigidity of the membrane corresponds to the closure of gaps in the surface layer of the membrane, and indicates the essential role of the membrane surface in transport processes.
Źródło:
Nukleonika; 2015, 60, No. 3, part 1; 395-398
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Concept of a Collection System for Gas Mixture from the Interior of Chimney Openings for Unmanned Flying Systems
Autorzy:
Klimczyk, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2123293.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
drone
UAV
air pollution
quality
environment
smog
probe
chimney
Opis:
Today, one of the most topical issues related to the quality and safety of life on Earth is the monitoring of air quality in terms of its pollution that is harmful to human health and life. The activities undertaken as part of monitoring carried out include, among others, analysis of the composition of exhaust fumes from emission sources, such as households and industrial entities, in terms of the presence therein of potentially hazardous substances, indirectly in order to detect violations of the applicable environmental standards. In order to conduct this type of analysis, unmanned aerial systems are commonly used, which allow sampling in the immediate vicinity of the emission source. However, the currently functioning solutions do not allow for exhaust fume sampling in a way that allows a mixture for testing to be taken directly from an emission source. This leads to questioning of the reliability of the conducted research, as it is uncertain in terms of the origin of the tested mixture, indicating that the test takes place not at the source of the emission, but in its surroundings. This study proposes a technical solution to sample exhaust fumes directly from the emission source - from the interior of chimney openings.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 3; 191--196
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified pressure-pressure sound intensity measurement method and its application to loudspeaker set directivity assessment
Autorzy:
Mickiewicz, Witold
Raczyński, Michał
Powiązania:
https://bibliotekanauki.pl/articles/220959.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sound intensity
pressure-pressure intensity probe
loudspeaker set measurements
Opis:
Sound intensity measurements using special sensors in a form of pressure-velocity and pressure-pressure probes are becoming more and more often the method of choice for characterization of sound sources. Its wider usability is blocked by the probes’ costs. This paper is on a possible modification of the well-known pressure-pressure sound intensity measurement method. In the proposed new approach a synchronized measurement procedure using only single microphone is used. The paper presents the basics of the sound intensity theory, a review of currently used methods of intensity measurement and requirements and limitations of the new method. In the proposed approach one microphone and a properly designed positioning system is used. The application of the method to study the directional characteristics of an active loudspeaker system have been described in detail. The obtained results were compared with those of measurements performed with a commercial p-u probe. The paper contains conclusions indicating advantages of the applied method in comparison with standard pressure measurement methods.
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 181-194
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A 2-Port, Space-Saving, Maintenance-Friendly Pneumatic Probe for Velocity Measurements
Autorzy:
Olczyk, A.
Magiera, R.
Kabalyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/221299.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pneumatic probes
probe calibration
uncertainty of measurements
velocity measurements
Opis:
This paper presents the concept, design and experimental results of tests, in laboratory conditions, of a 2-port, space-saving pneumatic probe. The main features of the probe are a result of restrictions imposed by the functioning environment: a limited space for probe installation, the possibility of processing only two output signals and requirements for simplicity and reliability of the probe. A cylindrical shape of the probe tip is proposed as a general concept, similar to the classic, cylindrical, 3-port probe. The main difference arises in using only two pressure signals: one from the overpressure zone on the front side of the cylinder and another, from the underpressure zone on the back side. After performing an appropriate calibration procedure, it is possible to measure the flow velocity and correct the pressure difference obtained by means of a velocity coefficient kv. This paper also presents an analysis of the kv coefficient uncertainty to evaluate the quality of measurements.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 171-185
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Częstotliwościowa metoda pomiaru zespolonej przenikalności dielektrycznej materiałów porowatych przy zastosowaniu sond o różnej długości
Frequency method for the measurement of the porous materials complex dielectric permittivity using probes of different length
Autorzy:
Wilczek, A.
Skierucha, W.
Powiązania:
https://bibliotekanauki.pl/articles/156814.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
właściwości gleby
zespolona przenikalność dielektryczna
sonda Open-Ended
sonda dwuprętowa
soil properties
complex dielectric permittivity
Open-Ended probe
two-rod probe
Opis:
Celem pracy jest porównanie dwóch metod pomiaru zespolonej przenikalności dielektrycznej gleby. W pierwszej metodzie wykorzystywanej do pomiarów referencyjnych użyta została sonda Open-Ended. W drugiej metodzie do pomiarów zostały wykorzystane sondy dwuprętowe o różnej długości, przy pomocy których dokonywano pomiaru przenikalności dielektrycznej w tak dobranych częstotliwościach, aby można je było traktować jako elementy o parametrach skupionych. W pracy przedstawiono kalibrację sond dwuprętowych metodą używaną do kalibracji sond Open-Ended. Polega ona na pomiarach sond w stanach zwarcia, rozwarcia i po umieszczeniu ich w ośrodku o znanych właściwościach dielektrycznych. Po kalibracji dokonano pomiarów parametrów odbiciowych na próbkach trzech gleb w wybranych częstotliwościach. Wszystkie pomiary wykonywane były wektorowym analizatorem sieci pracującym w zakresie częstotliwości 20 kHz + 8 GHz. Obiektami badanymi były trzy gleby o różnym rozkładzie granulometrycznym oraz wilgotności. Ze względu na specyfikę pomiaru w pracy przedstawiono analizę dla jednej tylko gleby. Porównanie wyników pozwala sądzić, że stosowane metody wykazują się wysoką korelacją wyników w przypadku pomiarów obu składowych zespolonej przenikalności dielektrycznej.
The main aim of the study is comparision of two measurement methods of the complex dielectric permittivity of soils. The first one used an Open-Ended probe and it was a reference method. The other one used two-rod probes of different length. These probes measured reflection parameters soils in selected frequencies that enabled to treat the probes as elements of lumped parameters. The study presents calibration of the two-rod probes using the method applied in Open-Ended probes. Il consists of measurements in shorted and open states as well as the measurement in a medium of known dielectric properties. All measurements were done using a vector network analyzer of the frequency range 20 kHz 8 GHz. Three soils of various texture and moisture were the analysed objects. Due to specificity of the measurement the paper presents the analysis for only one soil. The comparison of the measured data shows that the real and imaginary parts of the complex dielectric permittivity measured by both methods are highly correlated.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 680-682
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic field measurements on PF - 1000 and PF - 3 facilities: current sheath structure and neutron scaling
Autorzy:
Krauz, V. I.
Mitrofanov, K. N.
Scholz, M.
Myalton, V. V.
Paduch, M.
Grabovskii, E. V.
Karpinski, L.
Koidan, V. S.
Vinogradov, V. P.
Vinogradova, Y. V.
Zielinska, E.
Powiązania:
https://bibliotekanauki.pl/articles/147526.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus (PF)
magnetic probe
current sheath
neutron scaling
Opis:
The comparative analysis of the magnetic field distribution, the dynamics and structure of the plasma current sheath, and the neutron yield scaling in two largest plasma focus facilities, PF-3 and PF-1000 is done. The power-low dependence of the neutron yield on the current in the imploding plasma sheath has been demonstrated experimentally. For the first time the presence of the Bz magnetic field components is experimentally shown.
Źródło:
Nukleonika; 2012, 57, 2; 201-204
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of individual dopants in singe-electron devices - a study by KFM observation and simulation
Autorzy:
Ligowski, M.
Moraru, D.
Miftahul, A.
Tarido, J. C.
Mizuno, T.
Tabe, M.
Jabłoński, R.
Powiązania:
https://bibliotekanauki.pl/articles/385159.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
single dopant
Kelvin Probe Force Microscope
single-electron transfer
Opis:
Single electron devices (SEDs) are candidates to become a keystone of future electronics. They are very attractive due to low power consumption, small size or high operating speed. It is even possible to assure compatibility with present CMOS technology when natural potential fluctuations introduced by dopant atoms are used to create quantum dots (QD). However, the main problem of this approach is due to the randomness of dopant distribution which is characteristic for conventional doping techniques. This leads to scattered characteristics of the devices, which precludes from using them in the circuits. In these work we approach the problem of correlating the distribution of QD's with the device characteristics. For that, we investigate with a Kelvin probe force microscope (KFM) the surface potential of Si nanodevice channel in order to understand the potential landscape. Results reveal the features ascribable to individual dopants. These findings are supported also by simulation results.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 130-133
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interstellar Probe - where is the “nose” of the heliosphere?
Autorzy:
Ratkiewicz, Romana
Baraniecka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2204241.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Centrum Badań Kosmicznych PAN
Tematy:
heliosphere
heliosphere model
interstellar probe
paradigm shift
space logistics
Opis:
In this paper are reviewed publications that were concerned about the discovery of the location of the heliopause “nose” by the Newtonian Approximation method and publications using the full three-dimensional magnetohydrodynamic simulations of the heliosphere that confirmed that discovery. Since we do not have a clear answer to the question of what the heliosphere looks like, in connection with the planned launch of the Interstellar Probe within this decade, there was a problem with deciding which direction to send it. The discovery of the movement of the “nose” of the heliopause depending on the direction of the interstellar magnetic field and the determination of the position of the “nose” is very important for this decision. Therefore, the purpose of the article is to answer the question of where is the “nose” of the heliopause. In the second part of the article, the possibility of changing the paradigm of scientific research projects related to interstellar missions (including those focused on the study of the heliosphere), among other things, by increasing the interdisciplinarity of research, is explored. As part of initiating such cooperation, the article develops social sciences themes related to the sustainable logistics of Interstellar Probe missions to increase public involvement in these projects.
Źródło:
Artificial Satellites. Journal of Planetary Geodesy; 2023, 58, 1; 14--28
2083-6104
Pojawia się w:
Artificial Satellites. Journal of Planetary Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the influence of calibration sphere parameters on the results of articulating probe head qualification
Autorzy:
Gruza, Maciej
Gąska, Adam
Gąska, Piotr
Harmatys, Wiktor
Sładek, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/103260.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
calibration
accuracy
przegubowa głowica sondy
kalibrowanie
precyzja
Opis:
The qualification of probe heads before the measurements performed with their usage is now a standard procedure. It is used for correction of probe head’s and measuring tip systematic errors. The calibration sphere, which is used for this process, should have adequately small form errors. However, it is not always possible to use a highly accurate spheres and it is a common practice to use a sphere that was provided by the manufacturer of the CMM for a long time. This is why, the authors have tried to answer the question about the impact of the calibration sphere inaccuracies on the results of probe head qualification process.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 2; 252-259
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja pomiarów termoparowej sondy psychrometrycznej za pomocą współczynnika temperaturowego
Correction of the thermocouple psychrometer probe measurements using temperature coefficient
Autorzy:
Guz, Ł.
Targosińska, E.
Powiązania:
https://bibliotekanauki.pl/articles/127077.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
termoparowa sonda psychrometryczna
korekcja pomiarów
thermocouple psychrometer probe
readings correction
Opis:
Termoparowe sondy psychrometryczne służą do pomiaru potencjału wody. Często wykorzystywane są w agrotechnice. Znajduję też inne zastosowanie, np. w szczególnych przypadkach mogą zostać zastosowane do oceny wilgotności porowatych materiałów budowlanych. Zastosowanie w budownictwie drastycznie ogranicza ich wąski zakres pomiarowy, który mieści się w granicach 94÷99% wilgotności względnej powietrza. Odczyt z sondy psychrometrycznej jest dodatkowo funkcją zależną od temperatury. Dlatego podczas analizy wyników pomiarów przeprowadzonych w odmiennych warunkach środowiskowych należy dokonać korekcji wyników ze względu na temperaturę pomiaru. Celem niniejszej pracy jest przeanalizowanie sposobu wykorzystania korekcji temperaturowej dla termoparowych sond psychrometrycznych PST-55 Wescor. Kalibracja sond została przeprowadzona w laboratoryjnym piecu Memmert VO500 w temperaturach 20÷35°C. Wzrost temperatury o 1°C następował w ciągu 10 minut, a następnie temperatura utrzymywana była przez 2 godziny. Jako roztwór kalibrujący został użyty wodny roztwór NaCl o stężeniach: 0,4 M, 0,7 M, 1,1 M oraz 1,4 M. Zaproponowany został uogólniony wzór Ψ = f(U,T), wyznaczający potencjał wody w funkcji napięcia sondy i temperatury.
Thermocouple psychrometer probes are used to water potential measurement. They are often used in agricultural applications. Psychrometric probes can be also used in other domains, such as moisture estimation in the porous building materials. Their application in building physics is strongly limited by narrow sensitivity range of the sensors, which, varies between 94÷99% of relative humidity of air in the porous material. Also, readouts of the thermocouple probes are function of the temperature during measurement. Therefore, in order to analyze of the results of measurements performed in the different environmental conditions it is necessary to correct the results regarding to temperature. The aim of this article is to assessment of the temperature correction method for the thermocouple psychrometer probes Wescor PST-55. Calibration of the probe was carried out in a laboratory oven Memmert VO500 at a temperature range between 20 and 35°C. Temperature increase of 1°C appeared during 10 min period and afterwards the temperature was maintained for 2 hours. For calibration there were used NaCl solutions at molar concentrations 0.4 M, 0.7 M, 1.1 M and 1.4 M. The general Ψ=f(U,T) equation was proposed, which allow to calculate water potential as a function depending on voltage and temperature.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 714-718
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TaqMan real-time PCR for detecting bovine viral diarrhea virus
Autorzy:
Liang, H.
Geng, J.
Bai, S.
Aimuguri, A.
Gong, Z.
Feng, R.
Shen, X.
Wei, S.
Powiązania:
https://bibliotekanauki.pl/articles/2087557.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bovine viral diarrhea virus
quantitative real time PCR
TaqMan probe
Źródło:
Polish Journal of Veterinary Sciences; 2019, 2; 405-413
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strain gauge tool probe for NC lathes
Narzędziowa sonda tensometryczna
Autorzy:
Szafarczyk, M.
Chrzanowski, J.
Gościniak, R.
Powiązania:
https://bibliotekanauki.pl/articles/256745.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
sonda tensometryczna
sonda narzędziowa
naturalne zużycie ostrza
pomiar
nóż tokarski
obrabiarka NC
tool probe
tool wear
tool wear measurement
strain gauge tool probe
NC lathes
Opis:
This paper shows the original probe which is protected by patent pending, and original method which is developed for direct wear measurement at the tip of the cutting edge in turning. The measurement is made automatically on a NC lathe by means of a special probe, which enables at the same time, to determine the X, Z co-ordinate of the edge. The modified probe has 4 strain gauges connected to full-bridge sensor. The sensor is placed on a flat surface which is mounted under angle 45 degree in relation to measurement direction. This probe has a possibility of 4-axis measurement, in X-, X+, Z-, Z+ direction of tool movement using only one full-bridge sensor. The results of laboratory tests show great promise in a number of industrial applications.
W artykule przedstawiono rolę sond narzędziowych stosowanych na obrabiarkach NC. Ukazano obecne sposoby określania współrzędnych i zużycia ostrza. Przedstawiono koncepcję nowej sondy bazującej na mostkach tensometrycznych, która umożliwia podczas jednego cyklu pomiarowego określenie współrzędnych i bezpośredni pomiar zużycia ostrza noża tokarskiego na tokarkach NC przy czterech kierunkach ruchu narzędzia.
Źródło:
Problemy Eksploatacji; 2006, 4; 161-170
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relationship between the impedance of a multi-pin probe and soil water content
Autorzy:
Sun, Y.
Kromer, K.H.
Powiązania:
https://bibliotekanauki.pl/articles/24149.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
soil water
relationship
dielectrical constant
impedance
multi-pin probe
water content
Źródło:
International Agrophysics; 2003, 17, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of Wall Velocity Measurements Using Photonic Doppler Velocimetry (PDV)
Autorzy:
Künzel, M.
Němec, O.
Pachman, J.
Powiązania:
https://bibliotekanauki.pl/articles/358399.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
bare fiber probe
Gurney constant
pentaerythritol tetranitrate
photonic Doppler velocimetry
Semtex
Opis:
The paper describes the measurement of cylindrical charge wall velocity profiles at various angles to the surface normal. The wall velocities were measured using simple zero generation photonic Doppler velocimetry (PDV). The detonation velocity was measured simultaneously using fiber optic probes coupled with a digital chronometer. The PDV probe angles were set in the range of -2° to 17° to the surface normal. Powdered pentaerythritol tetranitrate (PETN) and the PETN-based plastic-bonded explosive Semtex 1A were selected as the explosive materials in order to ensure reliable detonation under the measurement conditions. The explosive charges were confined in thin-walled aluminum tubes with an internal diameter of 16 mm and wall thickness of 2 mm. The results can be useful for the characterization of charge expansion phenomena and also for the optimization of cylinder test measurements using PDV. Gurney constants were determined for both explosives.
Źródło:
Central European Journal of Energetic Materials; 2015, 12, 1; 89-97
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dopant-Based Charge Sensing Utilizing P-I-N Nanojunction
Autorzy:
Nowak, R.
Jabłoński, R.
Powiązania:
https://bibliotekanauki.pl/articles/220915.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nanosensor
silicon
p-i-n junction
dopant
Kelvin Probe Force Microscope
Opis:
We studied lateral silicon p-i-n junctions, doped with phosphorus and boron, regarding charge sensing feasibility. In order to examine the detection capabilities and underlying mechanism, we used in a complementary way two measurement techniques. First, we employed a semiconductor parameter analyzer to measure I−V characteristics at a low temperature, for reverse and forward bias conditions. In both regimes, we systematically detected Random Telegraph Signal. Secondly, using a Low Temperature Kelvin Probe Force Microscope, we measured surface electronic potentials. Both p-i-n junction interfaces, p-i and i-n, were observed as regions of a dynamic behaviour, with characteristic time-dependent electronic potential fluctuations. Those fluctuations are due to single charge capture/emission events. We found analytically that the obtained data could be explained by a model of two-dimensional p-n junction and phosphorus-boron interaction at the edge of depletion region. The results of complementary measurements and analysis presented in this research, supported also by the previous reports, provide fundamental insight into the charge sensing mechanism utilizing emergence of individual dopants.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 391-399
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of different probing systems used in articulated arm coordinate measuring machines
Autorzy:
Brau, A.
Valenzuela, M.
Santolaria, J.
Aguilar, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/221100.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
articulated arm coordinate measuring machine
probing systems
self-centering active probe
Opis:
This paper presents a comparison of different techniques to capture nominal data for its use in later verification and kinematic parameter identification procedures for articulated arm coordinate measuring machines (AACMM). By using four different probing systems (passive spherical probe, active spherical probe, self-centering passive probe and self-centering active probe) the accuracy and repeatability of captured points has been evaluated by comparing these points to nominal points materialized by a ball-bar gauge distributed in several positions of the measurement volume. Then, by comparing these systems it is possible to characterize the influence of the force over the final results for each of the gauge and probing system configurations. The results with each of the systems studied show the advantages and original accuracy obtained by active probes, and thus their suitability in verification (active probes) and kinematic parameter identification (self-centering active probes) procedures.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 233-246
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model kinetyczny przetwornika pasywnych głowic skaningowych CMM
Kinetic model of CMM scanning passive probe transducer
Autorzy:
Krajewski, G.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/155447.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica skanująca
współrzędnościowa maszyna pomiarowa
CMM
scanning probe
coordinate measuring machine
Opis:
W artykule przedstawiono analizę teoretyczną budowy przetwornika głowic skaningowych pasywnych stosowanych do pomiarów w technice współrzędnościowej. W efekcie podjętych prac autorzy otrzymali wstępny model dynamiczny pracy głowic, który może posłużć do kompensacji ich błędów powstałych na skutek zwiększenia prędkości pomiarowej.
Scanning probes, also known as measuring probes, are one of the most often used equipment of coordinate measuring machines (CMM) owing to ability of collecting large number of measuring points as well as taking fast measurements. High speed of measurements and high accuracy of the measuring system are two critical parameters deciding about the machine effectiveness. Dynamics is the most significant factor limiting the measurement accuracy. In most investigations of scanning CMM there is not separated the probing system performance from other sources of the machine errors, so the true error influenced by the probing system is not profoundly determined. This paper presents the scanning probe model regardless of the machine links. The worked out model allows for better understanding of the probing process with higher speed and optimising the measuring process. The future works will aim at proposing optimisation algorithms and applying them to the probing system as well as obtaining improvement in the accuracy.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 1, 1; 50-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa metoda generowania punktów offsetowych po skanowaniu CMM
The new method of generation of offset points after CMM scanning
Autorzy:
Filipowski, R.
Dąbrowski, L.
Zawora, J.
Powiązania:
https://bibliotekanauki.pl/articles/157835.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica pomiarowa
interpolacja
parametryzacja krzywej
probe head
interpolation
form of curve
Opis:
Skanowanie złożonych powierzchni na współrzędnościowej maszynie pomiarowej (CMM) jest szybką metodą ich pomiaru. Współrzędne punktów środka kulki głowicy pomiarowej w układzie współrzędnych kartezjańskich są zapisywane do zbioru danych w komputerze (PC). Każdy punkt pomiarowy jest określony przez wektor pozycyjny w prostokątnym układzie oraz parametr zmieniający się od zera do jedności. Przez punkty pomiarowe prowadzi się krzywe parametryczne Fergusona (splajn) a następnie przy ich pomocy generuje się punkty offsetowe. Zastosowane interpolacyjne funkcje Fergusona pozwalają uzyskać dobrą dokładność obliczenia położenia punktów offsetowych powierzchni mierzonych.
This paper presents a new method generating offset points after scanning process of cylindrical surface on the CMM, were in to the file of the connected PC using part coordinate system. The cartesian coordinates of points are transformed in parameter coordinates. By the processing of scanning data, the distance between points are made nearly equal. That way some points positioned too closely were eliminated form the calculation process. This closeness was caused by variation in CMM scanning speed. In the last step, the processed points with parameter coordinates were connected to the Ferguson function, thus enabling determining the position of the offset points. The parameter coordinates of points and the third degree curve (Ferguson curve) lead to very good accuracy of reverse engineering process for cylindrical surfaces.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 11, 11; 5-8
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie błędów głowicy pomiarowej z zastosowaniem metody Monte Carlo
Modeling of probing system errors by use of Monte Carlo method
Autorzy:
Sładek, J.
Juras, B.,
Krawczyk, M.
Gąska, A.
Powiązania:
https://bibliotekanauki.pl/articles/152502.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica pomiarowa
niepewność
metoda Monte Carlo
probe head
uncertainty
Monte Carlo
Opis:
W obecnych czasach, gdy nowoczesne techniki wytwarzania umożliwiają produkcję części z coraz to większą dokładnością, a tolerancje ich wykonania stają się coraz węższe, pojawia się potrzeba bardzo dokładnego wyznaczania niepewności pomiarów. Ważne jest również, aby proces estymacji niepewności stawał się jak najszybszy. Z tego powodu najlepiej rozwinięte laboratoria metrologiczne starają się stworzyć wirtualne modele WMP, które są w stanie wyznaczyć niepewność pomiarów w czasie quasi-rzeczywistym. Ten artykuł przedstawia sposób modelowania błędów głowicy pomiarowej z wykorzystaniem metody Monte Carlo. Błędy głowicy pomiarowej stanowią znaczną część całkowitych błędów maszyny pomiarowej, a zaprezentowany model może zostać wykorzystany jako jeden z modułów wirtualnej WMP.
Nowadays, when the manufacturing technologies are getting more and more precise, and the tolerances are getting narrower, there is a need of expressing the uncertainty of measurement at the really high level. It is also important to make the uncertainty estimation as quick as possible. This is why the most developed metrological laboratories are trying to create the virtual CMM models that can handle uncertainty evaluation in quasi-real time. This paper shows how to model, with use of the Monte Carlo method, the probing system errors which are one of the most significant errors of CMMs. The presented model can then be used as a module of virtual CMM. Paragraph 2 presents the theoretical basis of probing system operation. It also points out the factors causing probing system errors. The mentioned model of probe head errors is presented in Paragraph 3. Paragraph 4 gives the results of the measurements and simulations that have been performed to show functionality and correctness of the model. Conclusions and areas of development are presented in Paragraph 5.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 946-949
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie sondy lambda w systemie Motronic
Use of service knowledge in the diagnosis of network CAN
Autorzy:
Duer, S.
Warczyk, S.
Powiązania:
https://bibliotekanauki.pl/articles/314848.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
sterownik silnika
sonda lambda
system Motronic
motor controller unit
lambda probe
Opis:
W pracy przedstawiono problematykę badania układu sondy lambdda w systemie Motronic. Celem prowadzonych badań diagnostycznych jest określenie stanu sprawności układu sondy lambdda. Sonda lambdda ma duży wpływ z jednej strony na optymalne zużycie paliwa, a z drugiej strony na czystość spalin. Podstawowe badanie przy użyciu typowych metod i typowych narzędzi pomiarowych jest nie wystarczające. Pełniejszym badanie w układzie sony lambdda możliwym do wykonania „map roboczych”. W tym celu dokonuje się pomiarów sygnałów sterujących w układzie wtrysku paliwa jest czas wtrysku paliwa. Na podstawie tych pomiarów wykreślane są „mapy robocze”. Znajomość „map roboczych” w dalszym etapie badań są jest podstawą do analizy uzyskanych wyników pomiarowych z danymi zawartymi w bazach serwisowych np. bazie serwisowej „AutoData”. Sposób diagnostyki polega głównie na sprawdzeniu poprawności parametrów sygnałów badanych z ich sygnałami wzorcowymi zawartymi w bazie serwisowej.
The issues are presented in the study of the probe lambdda system Motronic. The aim of the study is to determine the diagnostic performance status of the probe lambdda. Poll lambdda has a big influence on the one hand for optimum fuel consumption and on the other hand, the purity of exhaust gases. The basic test using conventional methods and common tools of measurement is not sufficient. Fuller examination system lambdda possible to do "map work." For this purpose, the measurement control signals to the fuel injection system is a fuel injection time. On the basis of these measurements are plotted "maps working". Knowledge of the "working map" in the next stage of research are the basis for the analysis of the results from the measurement data contained in databases such service. Based service "Autodata". Method for the diagnosis relies mainly on checking the correctness of signal parameters studied with the calibrating signals contained in the database service.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 7-8; 153-158
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies