Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "probe" wg kryterium: Temat


Tytuł:
Probe radius correction methods - review and comparison of existing methods
Autorzy:
Rak, A.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/385250.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
coordinate measuring machine (CMM)
scanning probe
probe tip radius correction
Opis:
Scanning technology has been becoming more common then ever. Scanning offers new and effective possibilities of measurement. Nowadays planning, production and assembling without high accurate metrology is impossible. Measurement of small, curved elements became much easier with great development of mechanical components of measure machines, such as: guideways, transducers, bearings, servomechanisms. All this improvement made possible to collect with good accuracy points in high density. Algorithms, and computer software were greatly improved as well. Especially, many efforts were put on probe radius correction algorithms development. In this paper a review and a comparison of probe radius correction methods are shown.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 169-171
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of magnetized low temperature plasma by ball - pen probe
Autorzy:
Adámek, J.
Peterka, M.
Gyergyek, T.
Kudrna, P.
Tichý, M.
Powiązania:
https://bibliotekanauki.pl/articles/146432.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ball-pen probe
magnetron
Opis:
The ball-pen probe is an innovative electric probe for direct measurements of the plasma potential in magnetized hot plasma. This probe is based on the Katsumata probe concept. The ball-pen probe can adjust the ratio I- saturat/I+ saturat of the electron and ion saturation currents to be equal to one and therefore the ball-pen probe characterization becomes symmetric. If this is achieved, the floating potential of the ball-pen probe is equal to the plasma potential in Maxwellian plasma. We show the application of a ball-pen probe in slightly magnetized low temperature plasma.
Źródło:
Nukleonika; 2012, 57, 2; 297-300
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ARMScope – the versatile platform for scanning probe microscopy systems
Autorzy:
Świadkowski, Bartosz
Piasecki, Tomasz
Rudek, Maciej
Świątkowski, Michał
Gajewski, Krzysztof
Majstrzyk, Wojciech
Babij, Michał
Dzierka, Andrzej
Gotszalk, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/221551.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Scanning probe microscopy
AFM
Kelvin Probe force microscopy
scanning tunnelling microscopy
Opis:
Scanning probe microscopy (SPM) since its invention in the 80’s became very popular in examination of many different sample parameters, both in university and industry. This was the effect of bringing this technology closer to the operator. Although the ease of use opened a possibility for measurements without high labour requirement, a quantitative analysis is still a limitation in Scanning Probe Microscopes available on the market. Based on experience of Nano-metrology Group, SPM still can be considered as a tool for quantitative examination of thermal, electrical and mechanical surface parameters. In this work we present an ARMScope platform as a versatile SPM controller that is proved to be useful in a variety of applications: from atomic-resolution STM (Scanning Tunnelling Microscopy) to Multi-resonance KPFM (Kelvin Probe force microscopy) to commercial SEMs (Scanning electron microscopes).
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 119-130
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tilt-shift eddy current probe impact on information value of response signal
Autorzy:
Chudacik, V.
Smetana, M.
Powiązania:
https://bibliotekanauki.pl/articles/140578.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy current testing
eddy current probe
response signals
tilt-shift probe
Opis:
This article deals with the possibility for increasing of the informational value of a response signal using tilt-shift eddy current probe. Numerical simulations based on the FEM method using the OPERA 3D software as well as gained experimental results are presented. The simulated cracks are evaluated at the selected eddy current probe tilts and shifts with respect to conductive plate to obtain additional data needed for its evaluation and localization. Obtained simulation results are compared and discussed with the experimental results.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 133-140
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermionic vacuum arc diagnostic using emissive probe
Autorzy:
Tiron, V.
Aniculaesei, C.
Popa, G.
Powiązania:
https://bibliotekanauki.pl/articles/385290.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
thermionic vacuum arc
emissive probe
Opis:
In this paper, experimental results are presented on study of the copper thermionic vacuum arc using emissive probe. Experimental results show that plasma potential is direct related to the discharge voltage and it shows nonlinear distribution from the anodic melted spot towards to the plasma extremity.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 147-149
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of micro- and nanostructure using the scanning probe microscopy
Autorzy:
Gotszalk, T.
Janusz, P.
Marendziak, A.
Czarnecki, P.
Radojewski, J.
Szeloch, R. F.
Grabiec, P.
Rangelow, I. W.
Powiązania:
https://bibliotekanauki.pl/articles/308801.pdf
Data publikacji:
2005
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
scannig probe microscopy
microsystem
nanofabrication
Opis:
In this paper we summarize the results of our research concerning the diagnostics of micro- and nanostructure with scanning probe microscopy (SPM). We describe the experiments performed with one of the scanning probe microscopy techniques enabling also insulating surfaces to be investigated, i.e., atomic force microscopy (AFM). We present the results of topography measurements using both contact and non-contact AFM modes, investigations of the friction forces that appear between the microtip and the surface, and experiments connected with the thermal behaviour of integrated circuits, carried out with the local resolution of 20 nm.
Źródło:
Journal of Telecommunications and Information Technology; 2005, 1; 41-46
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A coumarin-based fluorescent probe for specific and rapid detection of fluoride ions
Autorzy:
Xin, Z.-H.
Meng, Y.-L.
Wu, Y.-H.
Feng, Z.-K.
Kang, Y.-F.
Powiązania:
https://bibliotekanauki.pl/articles/778907.pdf
Data publikacji:
2018
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Fluorion
Fluorescence
Coumarin
Probe
Bioimaging
Opis:
A simple and coumarin-based fluorescence probe has been designed and synthesized with silyl group as recognition group of fluoride ions (F−) in this study. The results showed that the fluorescence intensity of the probe displayed prominent enhancement with addition of F− at 445 nm with incubation of 1 min. There was an excellent linear relationship between fluorescence intensity and fluoride concentration from 0 to 30 μM (0~0.57 ppm), which offered the important condition for the quantitative analysis. In addition, the highly selective response to fluorion, the low detection limit with 28 nM (0.532 ppb), low toxicity and bioimaging afforded an advantage for practical application and detecting fluoride in biological systerms.
Źródło:
Polish Journal of Chemical Technology; 2018, 20, 4; 1-5
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of the measurement method of relative moisture determination using Peltier probe
Modyfikacja techniki pomiarowej do wyznaczania wilgotności względnej za pomocą sondy psychrometrycznej Peltiera
Autorzy:
Guz, Ł.
Suchorab, Z.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/127061.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
psychrometric probe
sleeves
sondy psychrometryczne
tuleje
Opis:
Psychrometric probes are used for porous materials potential determination which can be easily recalculated into the relative moisture. They can be also applied for building materials moisture parameters determination. They enable relative moisture readout in the narrow range between 94 and 99.9%. Water film evaporating from the thermocouple causes temperature decrease and generation of a voltage in a range of microvolts. Due to external heat flux influence on the applied sensors (Wescor PST-55 probes) the measurement must be conducted in the stabilized conditions. Non-stable heat flows and thus the decrease of measurement results repeatability. This is especially important during measurement of porous material samples with small dimensions. To increase the measurement accuracy the probes were equipped with metal sleeves having the external diameter of 12 mm and wall thickness 1 mm. The aim of the sleeve is to stabilize the instantaneous temperature variations and bridge the heat flow around the psychrometric Peltier probe.
Sondy psychrometryczne służą do pomiaru potencjału wody materiałów porowatych, którą można przeliczyć na wilgotność względną. Stosowane są od lat w agrotechnice i mogą również być zastosowane do pomiarów parametrów wilgotnościowych materiałów budowlanych. Umożliwiają odczyt wilgotności względnej w wąskim zakresie około 94÷99,9%. Jest to możliwe dzięki zjawisku Seebecka, odparowujący film wody z termopary powoduje obniżenie jej temperatury i wygenerowanie mikrowoltowego napięcia. Z uwagi na niską wartość mikrowoltowego napięcia generowanego na sondach Wescor PST-55, użytych podczas badań, pomiary muszą odbywać się w ustabilizowanych warunkach. Nieustabilizowane przepływy strumienia ciepła lub skoki temperatury powodują zmniejszenie powtarzalności wyników pomiarów. Ma to szczególne znaczenie podczas pomiarów próbek materiałów porowatych o niewielkich wymiarach geometrycznych. W celu zwiększenia dokładności pomiarów sondy zostały osłonięte metalowymi tulejami o średnicy 10 mm i grubości ścianki 1 mm. Zadaniem takiej tulei jest stabilizowanie nagłych wahań temperatury i regulowanie przepływów strumienia ciepła wokół sondy psychrometrycznej Peltiera.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 51-56
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of plasma diffusion coefficient in Pilot-PSI device using Katsumata probe
Autorzy:
Solomon, M. L.
Mihaila, I.
Anita, V.
Costin, C.
Popa, G.
van der Meiden, H.
Al, R.
van Rooij, G.
Cardozo, N. L.
Rapp, J.
Ionita, C.
Stärz, R.
Schrittwieser, R.
Powiązania:
https://bibliotekanauki.pl/articles/385269.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Katsumata probe
magnetized plasma
diffusion coefficient
Opis:
Cross-field transport of particles and energy is a major issue in magnetized fusion-relevant plasmas, due to its relevance for plasma confinement. In this paper Katsumata probe measurements performed in Pilot-PSI linear magnetized plasma device are presented. The plasma diffusion coefficient in perpendicular direction to the magnetic field was estimated from the measurements.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 160-162
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the impact of probe head hysteresis on the accuracy of five-axis coordinate measuring systems
Autorzy:
Gąska, P.
Gruza, M.
Gąska, A.
Harmatys, W.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102633.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
hysteresis
accuracy
CMM
Opis:
One of the factors affecting the accuracy of Coordinate Measuring Systems is hysteresis of a probe head. It is important especially in case of touch trigger probes and should be taken into account during the determination of probing strategy. In this article, the authors try to assess how this phenomenon affects the accuracy of five axis coordinate systems which utilize articulating probe head. Such systems allow to measure point coordinates using rotary movements of the head what introduces changes to the probing process. The experiments presented in this paper are based on multiple measurements of the reference elements such as gauge blocks and standard ring.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 277-282
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies