Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "probe" wg kryterium: Temat


Tytuł:
Probe radius correction methods - review and comparison of existing methods
Autorzy:
Rak, A.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/385250.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
coordinate measuring machine (CMM)
scanning probe
probe tip radius correction
Opis:
Scanning technology has been becoming more common then ever. Scanning offers new and effective possibilities of measurement. Nowadays planning, production and assembling without high accurate metrology is impossible. Measurement of small, curved elements became much easier with great development of mechanical components of measure machines, such as: guideways, transducers, bearings, servomechanisms. All this improvement made possible to collect with good accuracy points in high density. Algorithms, and computer software were greatly improved as well. Especially, many efforts were put on probe radius correction algorithms development. In this paper a review and a comparison of probe radius correction methods are shown.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 169-171
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of magnetized low temperature plasma by ball - pen probe
Autorzy:
Adámek, J.
Peterka, M.
Gyergyek, T.
Kudrna, P.
Tichý, M.
Powiązania:
https://bibliotekanauki.pl/articles/146432.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ball-pen probe
magnetron
Opis:
The ball-pen probe is an innovative electric probe for direct measurements of the plasma potential in magnetized hot plasma. This probe is based on the Katsumata probe concept. The ball-pen probe can adjust the ratio I- saturat/I+ saturat of the electron and ion saturation currents to be equal to one and therefore the ball-pen probe characterization becomes symmetric. If this is achieved, the floating potential of the ball-pen probe is equal to the plasma potential in Maxwellian plasma. We show the application of a ball-pen probe in slightly magnetized low temperature plasma.
Źródło:
Nukleonika; 2012, 57, 2; 297-300
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ARMScope – the versatile platform for scanning probe microscopy systems
Autorzy:
Świadkowski, Bartosz
Piasecki, Tomasz
Rudek, Maciej
Świątkowski, Michał
Gajewski, Krzysztof
Majstrzyk, Wojciech
Babij, Michał
Dzierka, Andrzej
Gotszalk, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/221551.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Scanning probe microscopy
AFM
Kelvin Probe force microscopy
scanning tunnelling microscopy
Opis:
Scanning probe microscopy (SPM) since its invention in the 80’s became very popular in examination of many different sample parameters, both in university and industry. This was the effect of bringing this technology closer to the operator. Although the ease of use opened a possibility for measurements without high labour requirement, a quantitative analysis is still a limitation in Scanning Probe Microscopes available on the market. Based on experience of Nano-metrology Group, SPM still can be considered as a tool for quantitative examination of thermal, electrical and mechanical surface parameters. In this work we present an ARMScope platform as a versatile SPM controller that is proved to be useful in a variety of applications: from atomic-resolution STM (Scanning Tunnelling Microscopy) to Multi-resonance KPFM (Kelvin Probe force microscopy) to commercial SEMs (Scanning electron microscopes).
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 119-130
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tilt-shift eddy current probe impact on information value of response signal
Autorzy:
Chudacik, V.
Smetana, M.
Powiązania:
https://bibliotekanauki.pl/articles/140578.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy current testing
eddy current probe
response signals
tilt-shift probe
Opis:
This article deals with the possibility for increasing of the informational value of a response signal using tilt-shift eddy current probe. Numerical simulations based on the FEM method using the OPERA 3D software as well as gained experimental results are presented. The simulated cracks are evaluated at the selected eddy current probe tilts and shifts with respect to conductive plate to obtain additional data needed for its evaluation and localization. Obtained simulation results are compared and discussed with the experimental results.
Źródło:
Archives of Electrical Engineering; 2016, 65, 1; 133-140
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermionic vacuum arc diagnostic using emissive probe
Autorzy:
Tiron, V.
Aniculaesei, C.
Popa, G.
Powiązania:
https://bibliotekanauki.pl/articles/385290.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
thermionic vacuum arc
emissive probe
Opis:
In this paper, experimental results are presented on study of the copper thermionic vacuum arc using emissive probe. Experimental results show that plasma potential is direct related to the discharge voltage and it shows nonlinear distribution from the anodic melted spot towards to the plasma extremity.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 147-149
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of micro- and nanostructure using the scanning probe microscopy
Autorzy:
Gotszalk, T.
Janusz, P.
Marendziak, A.
Czarnecki, P.
Radojewski, J.
Szeloch, R. F.
Grabiec, P.
Rangelow, I. W.
Powiązania:
https://bibliotekanauki.pl/articles/308801.pdf
Data publikacji:
2005
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
scannig probe microscopy
microsystem
nanofabrication
Opis:
In this paper we summarize the results of our research concerning the diagnostics of micro- and nanostructure with scanning probe microscopy (SPM). We describe the experiments performed with one of the scanning probe microscopy techniques enabling also insulating surfaces to be investigated, i.e., atomic force microscopy (AFM). We present the results of topography measurements using both contact and non-contact AFM modes, investigations of the friction forces that appear between the microtip and the surface, and experiments connected with the thermal behaviour of integrated circuits, carried out with the local resolution of 20 nm.
Źródło:
Journal of Telecommunications and Information Technology; 2005, 1; 41-46
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A coumarin-based fluorescent probe for specific and rapid detection of fluoride ions
Autorzy:
Xin, Z.-H.
Meng, Y.-L.
Wu, Y.-H.
Feng, Z.-K.
Kang, Y.-F.
Powiązania:
https://bibliotekanauki.pl/articles/778907.pdf
Data publikacji:
2018
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Fluorion
Fluorescence
Coumarin
Probe
Bioimaging
Opis:
A simple and coumarin-based fluorescence probe has been designed and synthesized with silyl group as recognition group of fluoride ions (F−) in this study. The results showed that the fluorescence intensity of the probe displayed prominent enhancement with addition of F− at 445 nm with incubation of 1 min. There was an excellent linear relationship between fluorescence intensity and fluoride concentration from 0 to 30 μM (0~0.57 ppm), which offered the important condition for the quantitative analysis. In addition, the highly selective response to fluorion, the low detection limit with 28 nM (0.532 ppb), low toxicity and bioimaging afforded an advantage for practical application and detecting fluoride in biological systerms.
Źródło:
Polish Journal of Chemical Technology; 2018, 20, 4; 1-5
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of the measurement method of relative moisture determination using Peltier probe
Modyfikacja techniki pomiarowej do wyznaczania wilgotności względnej za pomocą sondy psychrometrycznej Peltiera
Autorzy:
Guz, Ł.
Suchorab, Z.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/127061.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
psychrometric probe
sleeves
sondy psychrometryczne
tuleje
Opis:
Psychrometric probes are used for porous materials potential determination which can be easily recalculated into the relative moisture. They can be also applied for building materials moisture parameters determination. They enable relative moisture readout in the narrow range between 94 and 99.9%. Water film evaporating from the thermocouple causes temperature decrease and generation of a voltage in a range of microvolts. Due to external heat flux influence on the applied sensors (Wescor PST-55 probes) the measurement must be conducted in the stabilized conditions. Non-stable heat flows and thus the decrease of measurement results repeatability. This is especially important during measurement of porous material samples with small dimensions. To increase the measurement accuracy the probes were equipped with metal sleeves having the external diameter of 12 mm and wall thickness 1 mm. The aim of the sleeve is to stabilize the instantaneous temperature variations and bridge the heat flow around the psychrometric Peltier probe.
Sondy psychrometryczne służą do pomiaru potencjału wody materiałów porowatych, którą można przeliczyć na wilgotność względną. Stosowane są od lat w agrotechnice i mogą również być zastosowane do pomiarów parametrów wilgotnościowych materiałów budowlanych. Umożliwiają odczyt wilgotności względnej w wąskim zakresie około 94÷99,9%. Jest to możliwe dzięki zjawisku Seebecka, odparowujący film wody z termopary powoduje obniżenie jej temperatury i wygenerowanie mikrowoltowego napięcia. Z uwagi na niską wartość mikrowoltowego napięcia generowanego na sondach Wescor PST-55, użytych podczas badań, pomiary muszą odbywać się w ustabilizowanych warunkach. Nieustabilizowane przepływy strumienia ciepła lub skoki temperatury powodują zmniejszenie powtarzalności wyników pomiarów. Ma to szczególne znaczenie podczas pomiarów próbek materiałów porowatych o niewielkich wymiarach geometrycznych. W celu zwiększenia dokładności pomiarów sondy zostały osłonięte metalowymi tulejami o średnicy 10 mm i grubości ścianki 1 mm. Zadaniem takiej tulei jest stabilizowanie nagłych wahań temperatury i regulowanie przepływów strumienia ciepła wokół sondy psychrometrycznej Peltiera.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 51-56
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of plasma diffusion coefficient in Pilot-PSI device using Katsumata probe
Autorzy:
Solomon, M. L.
Mihaila, I.
Anita, V.
Costin, C.
Popa, G.
van der Meiden, H.
Al, R.
van Rooij, G.
Cardozo, N. L.
Rapp, J.
Ionita, C.
Stärz, R.
Schrittwieser, R.
Powiązania:
https://bibliotekanauki.pl/articles/385269.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Katsumata probe
magnetized plasma
diffusion coefficient
Opis:
Cross-field transport of particles and energy is a major issue in magnetized fusion-relevant plasmas, due to its relevance for plasma confinement. In this paper Katsumata probe measurements performed in Pilot-PSI linear magnetized plasma device are presented. The plasma diffusion coefficient in perpendicular direction to the magnetic field was estimated from the measurements.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 160-162
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the impact of probe head hysteresis on the accuracy of five-axis coordinate measuring systems
Autorzy:
Gąska, P.
Gruza, M.
Gąska, A.
Harmatys, W.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102633.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
hysteresis
accuracy
CMM
Opis:
One of the factors affecting the accuracy of Coordinate Measuring Systems is hysteresis of a probe head. It is important especially in case of touch trigger probes and should be taken into account during the determination of probing strategy. In this article, the authors try to assess how this phenomenon affects the accuracy of five axis coordinate systems which utilize articulating probe head. Such systems allow to measure point coordinates using rotary movements of the head what introduces changes to the probing process. The experiments presented in this paper are based on multiple measurements of the reference elements such as gauge blocks and standard ring.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 277-282
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impedance measurements problem in antennas for RFID technique
Autorzy:
Jankowski-Mihułowicz, P.
Pitera, G.
Węglarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/221609.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
RFID
antenna
impedance measurement
differential probe
Opis:
The authors paid particular attention to the problem of antenna impedance measurements in the RFID technique. These measurements have to be realized by using two ports of a vector network analyzer and dedicated passive differential probes. Since the measurement process and estimated parameters depend on the frequency band, operating conditions, type of the system component and antenna designs used, appropriate verification of the impedance parameters on the basis of properly conducted experiments is a crucial stage in the antenna synthesis of transponders and read/write devices. Accordingly, a systematized procedure of impedance measurements is proposed. It can be easily implemented by designers preparing antennas for different kinds of RFID applications. The essence of indirect measurements of the differential impedance parameters is discussed in details. The experimental verification has been made on the basis of a few representative examples.
Źródło:
Metrology and Measurement Systems; 2014, 21, 3; 509-520
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a carbazole derivative as a spectroscopic fluorescent probe for real time monitoring of cationic photopolymerization
Autorzy:
Ortyl, J.
Galica, M.
Popielarz, R.
Bogdał, D.
Powiązania:
https://bibliotekanauki.pl/articles/778445.pdf
Data publikacji:
2014
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
spectroscopic fluorescent probe
FPT
fluorescence
carbazole
photopolymerization
Opis:
The performance of 1-(9-ethylcarbazol-3-yl)-4,4,4-trifluorobutane-1,3-dione (1) as a fluorescent probe for the monitoring of cationic photopolymerization processes by Fluorescence Probe Technique (FPT) has been evaluated in comparison with the response of 7-diethylamino-4-methylcoumarin (Coumarin 1) (2). Triethylene glycol divinyl ether and diphenyliodonium hexafluorophosphate were used as an example monomer and a cationic photoinitiator respectively. It has been found that the probe 1 withstands the cationic polymerization conditions and provides correct probe response. 1-(9-ethylcarbazol-3-yl)-4,4,4-trifluorobutane-1,3-dione shifts its fluorescence spectrum with progress of cationic photopolymerization of the monomer, which enables the monitoring of the polymerization progress using the fluorescence intensity ratio measured at two different wavelengths as the progress indicator. By comparing the behavior of 1 and 2, it has been documented that the fluorescence spectrum of probe 1 shows a spectacular hypsochromic shift (Δλ = 33 nm) upon the monomer polymerization, while the shift of 2 is three times smaller (Δλ = 11 nm). Moreover, the sensitivity of probe 1 is more than 2.5-times higher than that of any other probes suitable for monitoring cationic polymerization processes, reported previously. Therefore, application of the carbazole derivative (1) as a new probe for the monitoring of the crosslinking process of coatings cured by cationic photopolymerization has been proposed.
Źródło:
Polish Journal of Chemical Technology; 2014, 16, 1; 75-80
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Employing Optical Measurements for Monitoring and Diagnostics of Combustion Process in Industrial Conditions
Autorzy:
Wójcik, W.
Suleimenov, B.
Junisbekov, M.
Kalizhanova, A.
Smailova, S.
Mussabekov, R.
Powiązania:
https://bibliotekanauki.pl/articles/124530.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
combustion process
fiber optic probe
signal analysis
Opis:
The paper discusses some practical problems conected with introdction of modern coal combustion technologies as well as biomass co-combustion. In order to ensure that the combustion process runs in a proper way, the multichannel fiber optic monitoring system was applied. The system converts the optical signals coming from several flame zones to electrical that were further transmitted to the control room. The article prsents signal analyses made in time-frequency domain using short-time Fourier transform and wavelet transform and the way of their visualization to power boiler operators.
Źródło:
Journal of Ecological Engineering; 2017, 18, 1; 273-283
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie krzywej retencji wody materiałów porowatych za pomocą sond psychometrycznych i TDR
Determination of the water retention curves for porous materials using psychrometric probes combined with TDR methodology
Autorzy:
Guz, Ł.
Suchorab, Z.
Alcobia, B.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/126951.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
psychrometria
sonda TDR
krzywa retencji
materiały porowate
psychrometric probe
TDR probe
soil water retention curve
porous materials
Opis:
Woda jest bardzo ważnym składnikiem produkcji materiałów budowlanych. Jest również jednym z najbardziej destruktywnych czynników podczas późniejszej eksploatacji obiektów z nich zbudowanych. Z tego względu niezbędna jest znajomość właściwości wilgotnościowych materiałów, takich jak: podsiąkanie kapilarne, opór dyfuzyjny czy nasiąkliwość. Właściwości materiałów porowatych związanych z wilgotnością bardzo dobrze opisuje krzywa retencji wody. Określa ona, jaką ilość wody materiał porowaty jest w stanie wchłonąć oraz z jaką siłą utrzymuje wodę w przestrzeniach porowatych. Jest to zależność pomiędzy ciśnieniem ssącym wodę a zawartością wody. W niniejszej pracy przedstawiono krzywe retencji wody wyznaczone dla gazobetonu o gęstości 450; 550 i 650 kg/m3. Krzywa została wyznaczona poprzez sprzężenie dwóch technik pomiarowych: psychrometrycznej i reflektometrycznej TDR. Ciśnienie ssące było zmierzone za pomocą sond psychrometrycznych Peltiera, a wilgotność objętościowa poprzez sondy TDR. Krzywa retencji opisana w publikacji została wyznaczona tylko w wąskim zakresie, determinowanym czułością sond psychrometrycznych, który mieścił się w granicach od 0,03 do 0,12 m3/m3 wilgotności objętościowej materiału porowatego.
Water is an important compound of building materials production technology. On the other hand it is one of the most destructive factor during exploitation of building objects. That is why it is necessary to know the moisture parameters of the materials like porosity, maximum water content, capillary rise and water conductivity. Water parameters of the porous materials can be described by water retention curve, which valuates what amount of water can be absorbed by the material and what force remains water in air gaps. It is dependence between water potential and moisture. In this work there are presented water retention curves determined for aerated concrete with the apparent density of 450, 550 and 650 kg/m3. Determination of water retention curve was achieved by combination of two measuring techniques: Peltier psychrometric probes for water potential and TDR for water content. Water retention curve described in the paper was established only in a small range of moisture which is mainly caused by the sensitivity of the psychrometric probes, which value was varying in the frames of material moisture between 0.03 and 0.12 m3/m3.
Źródło:
Proceedings of ECOpole; 2010, 4, 2; 371-375
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seebeck coefficient measurement by Kelvin-probe force microscopy
Autorzy:
Ikeda, H.
Salleh, F.
Asai, K.
Powiązania:
https://bibliotekanauki.pl/articles/384281.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
Seebeck coefficient
Kelvin-probe force microscopy
nanostructure
Opis:
In order to measure the Seebeck coefficient of nanometer-scale thermoelectric materials, we propose a new technique in which the thermoelectric-motive force (TEMF) is evaluated by Kelvin-probe force microscopy (KFM). In this study, we measured the Seebeck coefficient of an n-type Si wafer. The surface-potential difference between the high- and low-temperature regions on the Si wafer increases with increasing temperature difference. This indicates that the TEMF can be measured by KFM. The Seebeck coefficient evaluated from the surface-potential difference is 0.71š0.08 mV/K, which is close to that obtained by the conventional method.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 49-51
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A near-infrared fluorescent probe for selective detection of fluorion
Autorzy:
Kang, Yan-Fei
Wei, Fan
Meng, Ya-Li
Xin, Zhen-Hui
Wei, Dong
Powiązania:
https://bibliotekanauki.pl/articles/778367.pdf
Data publikacji:
2020
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Probe
Fluorescence
Fluoride anion
Selectivity
Near-infrared
Opis:
In this work, we have designed and synthesized the fluorescent probe 1, which was capable to selectively detect fluoride anion (F). More importantly, the probe 1 possessed near-infrared excitation and emission wavelengths (excitation at 650 nm and emission at 695), and the probe solution had changed dramatically from yellow to cyan with the addition of F. In addition, the fluorescence intensity exhibited perfectly positive correlation with concentration of F concentration from 0 to 40 μM (R2 = 0.9972), which offered the important condition for quantitative analysis. The probe 1 owned detection limit of 46 nM. Therefore, this near-infrared probe can be of great benefit for detecting F in practical application.
Źródło:
Polish Journal of Chemical Technology; 2020, 22, 1; 1-5
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A characterization of 2-tree probe interval graphs
Autorzy:
Brown, David E.
Flesch, Breeann M.
Lundgren, J. Richard
Powiązania:
https://bibliotekanauki.pl/articles/30148257.pdf
Data publikacji:
2014-08-01
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
interval graph
probe interval graph
2-tree
Opis:
A graph is a probe interval graph if its vertices correspond to some set of intervals of the real line and can be partitioned into sets P and N so that vertices are adjacent if and only if their corresponding intervals intersect and at least one belongs to P. We characterize the 2-trees which are probe interval graphs and extend a list of forbidden induced subgraphs for such graphs created by Pržulj and Corneil in [2-tree probe interval graphs have a large obstruction set, Discrete Appl. Math. 150 (2005) 216-231]
Źródło:
Discussiones Mathematicae Graph Theory; 2014, 34, 3; 509-527
2083-5892
Pojawia się w:
Discussiones Mathematicae Graph Theory
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interstellar probe: science, engineering, logistic, economic, and social factors
Autorzy:
Ratkiewicz, Romana
Baraniecka, Anna
Stępniewski, Kajetan
Miś, Tomasz
Błądek, Piotr
Tkacz, Arkadiusz
Mikołajków, Tomasz
Kozanecki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/27314483.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Centrum Badań Kosmicznych PAN
Tematy:
Interstellar Probe mission
science
engineering
logistic
business
Opis:
In this publication, we refer to a certain novelty introduced to the presentation at the AGU 2020 conference. This novelty consists of quoting the thoughts, remarks, and comments of six young people who declared their interest in space research after listening to a lecture on the Interstellar Probe journey, organized in June 2020 by the Polish Space Agency. Therefore, they were then asked to express their comments after reading two publications on the Interstellar Probe that were sent to them. As a result, this idea also became the topic of this article. Although the interstellar mission is primarily a research and science project, its engineering, logistics, business (economic), and social aspects, as well as a short commentary on our home in the universe, which is the heliosphere, have also been included in this article.
Źródło:
Artificial Satellites. Journal of Planetary Geodesy; 2023, 58, 2; 29--41
2083-6104
Pojawia się w:
Artificial Satellites. Journal of Planetary Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie sondy CPTU 15 cm2 do badań podłoża gruntowego
The use of 15 cm2 CPTU for investigations of subsoil
Autorzy:
Bajda, M.
Biliniak, M.
Lech, M.
Powiązania:
https://bibliotekanauki.pl/articles/40404.pdf
Data publikacji:
2012
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
geotechnika
grunty
badania terenowe
sondowanie statyczne
sonda CPTU
wykorzystanie
geotechnics
soil
field research
static sounding
CPTU probe
probe use
Źródło:
Acta Scientiarum Polonorum. Architectura; 2012, 11, 2
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy związane z korekcją promienia końcówki pomiarowej podczas skaningowych pomiarów współrzędnościowych
Difficulties with the corrected measured point determination in coordinate metrology
Autorzy:
Woźniak, A.
Mayer, M.
Cote, M.
Powiązania:
https://bibliotekanauki.pl/articles/153572.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Współrzędnościowa Maszyna Pomiarowa
WMP
sonda głowica skaningowa
korekcja promienia końcówki
Coordinate Measuring Machine
CMM
scanning probe
probe radius compensation
Opis:
W artykule przedstawiono analizy teoretyczne i badania doświadczalne potwierdzające, że korekcja promienia końcówki pomiarowej może być istotnym źródłem błędów podczas saningowych pomiarów przeprowadzanych na maszynach współrzędnościowych. Przedstawiono wyniki pomiarów przykładowego elementu na maszynie Mitutoyo LEGEX 910 CMM wyposażonej w sondę skaningową MPP-300, ze wskazaniem mechanizmów złej korekcji promienia końcówki pomiarowej.
Paper discusses an understanding for the compensation of the probe ball radius in a scanning process carried out by coordinate measuring machines (CMM). According to some initial trials of scanning measurement using the stylus tip radius correction built-in the CMM software, it was found, as will be shown in the paper, that the indigenous CMM software do not compensate the stylus tip radius well. As a result, the information about the real shape of the measured reatures can be distored. The difficulties with the corrected measured point determination will be demonstrate no the basis of tests were carried out on a Mitutoyo LEGEX 910 CMM equipped with a MPP-300 scanning probe.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 485-488
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe
Powtarzalność i odtwarzalność pomiarów lokalizacji taśmy podcewkowej uzyskanych w USG dna miednicy wykonywanym głowicą przezpochwową
Autorzy:
Dresler, Maria Magdalena
Kociszewski, Jacek
Wlaźlak, Edyta
Pędraszewski, Piotr
Trzeciak, Agnieszka
Surkont, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1033435.pdf
Data publikacji:
2017
Wydawca:
Medical Communications
Tematy:
pelvic ultrasound
repeatability
suburethral tape
transvaginal probe
urogynecology
Opis:
Introduction: Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study: The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods: The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results: The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions: Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes.
Wstęp: Implanty stosowane do leczenia pacjentek z dolegliwościami uroginekologicznymi są dobrze widoczne w badaniu ultrasonograficznym. Lokalizacja taśmy podcewkowej określana jest w stosunku do cewki moczowej oraz spojenia łonowego. Cel pracy: Celem pracy była ocena dokładności pomiarów określających lokalizację taśmy podcewkowej uzyskanych podczas badania ultrasonograficznego dna miednicy wykonywanego głowicą przezpochwową. Materiał i metody: Analizą objęto wyniki pomiarów ultrasonograficznych przeprowadzonych zgodnie z wystandaryzowaną techniką u kobiet, które zostały skierowane na diagnostykę uroginekologiczną. Do analizy powtarzalności i odtwarzalności wyników uzyskanych tego samego dnia wykorzystano dane od 68 pacjentek. Wyniki: Współczynnik korelacji wewnątrzklasowej dla powtarzalności oraz odtwarzalności pomiarów lokalizacji taśmy podcewkowej uzyskanych w badaniu ultrasonograficznym głowicą przezpochwową wahał się od 0,6665 do 0,9911. Analiza pomiarów lokalizacji taśmy podcewkowej potwierdziła ich zgodność na bardzo dobrym i dobrym poziomie. Wnioski: Bardzo dobra i dobra powtarzalność oraz odtwarzalność pomiarów lokalizacji taśmy podcewkowej uzyskanych w badaniu ultrasonograficznym dna miednicy wykonywanym głowicą przezpochwową stanowią potwierdzenie możliwości zastosowania tego badania w praktyce klinicznej i w badaniach naukowych. Artykuł w wersji polskojęzycznej jest dostępny na stronie http://jultrason.pl/index.php/wydawnictwa/volume-17-no-69
Źródło:
Journal of Ultrasonography; 2017, 17, 69; 101-105
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of measured workpiece’s form errors influence on the accuracy of probe heads used on five-axis measuring systems
Autorzy:
Harmatys, W.
Gąska, A.
Gruza, M.
Gąska, P.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102182.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
five-axis system
accuracy
CMM
Opis:
The five-axis measuring systems are one of the most modern inventions in coordinate measuring technique. They are capable of performing measurements using only the rotary pairs present in their kinematic structure. This possibility is very useful because it may cause significant reduction of total measurement time and costs. However, it was noted that high values of measured workpiece’s form errors may cause significant reduction of the accuracy of a five-axis measuring system. The investigation on the relation between these two parameters was conducted in this paper and possible reasons of decrease in measurement accuracy was discussed on the example of measurements of workpieces with form errors ranging from 0,5 to 1,7 millimetre.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 305-310
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of multiple velocity and temperature probe sets for ventilated spaces
Autorzy:
Alimardani, R.
Hoff, S.J.
Powiązania:
https://bibliotekanauki.pl/articles/24933.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
temperature measurement
temperature
ventilation
probe
development
thermistor
velocity
Źródło:
International Agrophysics; 2005, 19, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Sensitivity Field of Dual Transducer Probes on Accuracy of Discontinuity Sizing and Evaluation in Terms of Testing of Forgings According to EN 10228-3
Autorzy:
Kaczmarek, R.
Kaczmarek, K.
Powiązania:
https://bibliotekanauki.pl/articles/352659.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
non destructive testing
ultrasonic testing
double transducer probe
Opis:
The article presents results of research on the impact of sensitivity distribution of double transducer probes, which are often used in non-destructive ultrasonic testing of components such as forgings. Distribution of sensitivity measured in two orientations, parallel and perpendicular to the plane of separation of a double transducer probe has been tested and analyzed. A significant influence of orientation of a probe on echo envelope of an artificial point discontinuity has been studied. It has revealed great differences in length and shape of an echo envelope, depending on a type of probe and orientation of a probe separation plane to the moving direction. Eventually, the analysis of practical consequences of dual transducer probes usage for characterization of a type, dimensioning and evaluation of internal discontinuities, in accordance to the methodology specified in EN 10228, has been conducted.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 3; 1677-1682
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensation of systematic errors of damaged probe for on-machine measurement
Autorzy:
Wozniak, A.
Jankowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/99611.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
on-machine measurement
touch trigger probe
errors compensation
Opis:
Spatial characteristic of triggering radius of the damaged probe for the CNC machine tools has been presented. In such case a clear distortion of the probe performance characteristic and a significant increase in probe errors have been observed. Then, to such a damaged probe, a variable speed correction method of systematic errors was used. By setting proper measurement speeds, varying for different measurement directions, errors of the probe can be significantly reduced.
Źródło:
Journal of Machine Engineering; 2018, 18, 1; 88-94
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vibro piles performance prediction using result of CPT
Autorzy:
Więcławski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2037706.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Vibro piles
ultimate capacity
settlement curve
CPT probe
Opis:
Vibro piles belong to the group of full displacement piles with an expanded base, characterised by a very high load capacity, especially in non-cohesive soils. The problem is to adopt a reliable method for the determination of full load-settlement (Q-s) curve. A frequent difficulty is the determination of the load capacity limit based on the static load test because the course of the load-settlement curve is of a linear nature. This publication presents the empirical method. It allows direct prediction of a full axially loaded pile settlement curve based on the values of qc cone resistance obtained in cone penetration test (CPT). The advantage offered by this procedure is the accuracy of the obtained limit values in relation to the actual load-bearing capacity as compared to other methods based on soil parameters obtained in in situ testing. An additional advantage is the Q-s characteristics, which enable designing for intermediate values, allowing for the criterion of minimal or equal settlements. The shape of analytical curves was compared with static pile load test (SPLT) curves. This comparison showed large convergences between the analytical and measured curves.
Źródło:
Studia Geotechnica et Mechanica; 2021, 43, 4; 452-464
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
(Brak) kontroli jakości urządzeń ultrasonograficznych
(Lack of) quality control of ultrasound devices
Autorzy:
Jędrzejewska, Monika
Węckowski, Bartosz
Jankowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2146813.pdf
Data publikacji:
2021
Wydawca:
Indygo Zahir Media
Tematy:
ultrasonografia
kontrola jakości
sonda
ultrasonography
quality control
probe
Opis:
Kontrola jakości aparatury ultrasonograficznej budzi wiele kontrowersji. W Polsce opiera się ona na błędnym założeniu, że ultrasonografia jest nieszkodliwa, nie powinna zatem podlegać takiej kontroli jak metody diagnostyczne bazujące na promieniowaniu jonizującym. Powyższe nie eliminuje jednak potrzeby prowadzenia testów kontroli jakości. Kryterium braku szkodliwości nie zmienia faktu, że nieprawidłowe funkcjonowanie systemu obrazowania może stanowić zagrożenie dla zdrowia i życia pacjentów ze względu na błędną diagnozę. W artykule zaproponowano schemat postępowania w zakresie oceny ultrasonografów, sond, protokołu pomiarowego oraz uzyskanych wyników i weryfikacji poprawności rejestracji obrazu.
The quality control of the ultrasound equipment is controversial. In Poland, it is based on the erroneous assumption that ultrasonography is harmless, therefore it should not be subject to such control as diagnostic methods based on ionizing radiation. However, the above does not eliminate the need to conduct quality control tests. The non-harmfulness criterion does not change the fact that improper functioning of the imaging system may pose a threat to the health and life of patients due to incorrect diagnosis. The article proposes a procedure for the assessment of ultrasound scanners, probes, measurement protocol, the obtained results and verification of the correctness of image registration.
Źródło:
Inżynier i Fizyk Medyczny; 2021, 10, 1; 69--75
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Urządzenie do lokalizacji sensorów pomiarowych w sondach temperatury wykorzystywane do precyzyjnego wyznaczania SND w konserwie
A device for locating measuring sensors in temperature probes used for precise determination of SHZ in cans
Autorzy:
Szczepka, Maciej
Stasiak, Alicja
Czyżewski, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/270989.pdf
Data publikacji:
2019
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
strefa najmniejszego dogrzania
sonda temperatury
wielokanałowa sonda temperatury
czujnik temperatury
slowest heating zone
temperature probe
multi-channel temperature probe
temperature sensor
Opis:
Artykuł opisuje przyrząd pomiarowy służący do precyzyjnego lokalizowania czujników temperatury w obudowach sond temperatury. Opis dotyczy budowy urządzenia oraz metody pomiarowej.
The article describes a measuring instrument used for precise location of temperature sensors in temperature probe casings. The description concerns the construction of the device and the measurement method.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2019, 24, 3; 193-196
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary laboratory tests of a new fibre optic high temperature measurement device
Autorzy:
Lisiecka, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/173508.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
non-contact thermometer
high temperature measurements
fibre optic probe
Opis:
This article presents the laboratory verification of the author’s algorithm for temperature determination. The conducted tests confirm the ability to eliminate the measurement condition impact (emissivity of the radiation source, attenuation of the atmosphere) on non-contact thermometric measurement results. What is more, this method allows measurement for wavelength shorter than 1 µm to be carried out. The second stage of the work involved transmission tests of the fibre optic probe. The use of three quartz rods ensured that thermal radiation from each direction in a perpendicular plane to the probe head is collected and transmitted. The combination of the new temperature determination method and new constructed measurement instrument will allow the area of application of a non-contact thermometric device to be extended.
Źródło:
Optica Applicata; 2019, 49, 4; 669-677
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement uncertainty analysis of different CNC machine tools measurement systems
Autorzy:
Semotiuk, L.
Józwik, J.
Kuric, I.
Powiązania:
https://bibliotekanauki.pl/articles/102390.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
measurement uncertainty
inspection probe
control system
CNC machine tool
Opis:
In this paper the results of measurement uncertainty tests conducted with a Heidenhain TS 649 probe on CNC machine tools are presented. In addition, identification and analysis of random and systematic errors of measurement were presented. Analyses were performed on the basis of measurements taken on two different CNC machine tools with Heidenhain control system. The evaluated errors were discussed and compensation procedures were proposed. The obtained results were described in tables and figures.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 19; 41-47
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The dynamics of the surface layer of lipid membranes doped by vanadium complex : computer modeling and EPR studies
Autorzy:
Olchawa, R.
Man, D.
Pytel, B.
Powiązania:
https://bibliotekanauki.pl/articles/147585.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
EPR probe
lipid membrane
membrane fluidity
Monte Carlo simulation
Opis:
Penetration of the liposome membranes doped with vanadium complex formed in the liquid-crystalline phase from egg yolk lecithin (EYL) by the TEMPO (2,2,6,6-tetramethylpiperidine-1-oxyl) spin probes has been investigated. The penetration process was followed by 360 hours at 24◦C, using the electron spin resonance (EPR) method. The spectroscopic parameter of the partition (F) of this probe indicated that a maximum rigidity of the membrane was at 3% concentration of the vanadium complex. Computer simulations showed that the increase in the rigidity of the membrane corresponds to the closure of gaps in the surface layer of the membrane, and indicates the essential role of the membrane surface in transport processes.
Źródło:
Nukleonika; 2015, 60, No. 3, part 1; 395-398
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Concept of a Collection System for Gas Mixture from the Interior of Chimney Openings for Unmanned Flying Systems
Autorzy:
Klimczyk, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2123293.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
drone
UAV
air pollution
quality
environment
smog
probe
chimney
Opis:
Today, one of the most topical issues related to the quality and safety of life on Earth is the monitoring of air quality in terms of its pollution that is harmful to human health and life. The activities undertaken as part of monitoring carried out include, among others, analysis of the composition of exhaust fumes from emission sources, such as households and industrial entities, in terms of the presence therein of potentially hazardous substances, indirectly in order to detect violations of the applicable environmental standards. In order to conduct this type of analysis, unmanned aerial systems are commonly used, which allow sampling in the immediate vicinity of the emission source. However, the currently functioning solutions do not allow for exhaust fume sampling in a way that allows a mixture for testing to be taken directly from an emission source. This leads to questioning of the reliability of the conducted research, as it is uncertain in terms of the origin of the tested mixture, indicating that the test takes place not at the source of the emission, but in its surroundings. This study proposes a technical solution to sample exhaust fumes directly from the emission source - from the interior of chimney openings.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 3; 191--196
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified pressure-pressure sound intensity measurement method and its application to loudspeaker set directivity assessment
Autorzy:
Mickiewicz, Witold
Raczyński, Michał
Powiązania:
https://bibliotekanauki.pl/articles/220959.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sound intensity
pressure-pressure intensity probe
loudspeaker set measurements
Opis:
Sound intensity measurements using special sensors in a form of pressure-velocity and pressure-pressure probes are becoming more and more often the method of choice for characterization of sound sources. Its wider usability is blocked by the probes’ costs. This paper is on a possible modification of the well-known pressure-pressure sound intensity measurement method. In the proposed new approach a synchronized measurement procedure using only single microphone is used. The paper presents the basics of the sound intensity theory, a review of currently used methods of intensity measurement and requirements and limitations of the new method. In the proposed approach one microphone and a properly designed positioning system is used. The application of the method to study the directional characteristics of an active loudspeaker system have been described in detail. The obtained results were compared with those of measurements performed with a commercial p-u probe. The paper contains conclusions indicating advantages of the applied method in comparison with standard pressure measurement methods.
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 181-194
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A 2-Port, Space-Saving, Maintenance-Friendly Pneumatic Probe for Velocity Measurements
Autorzy:
Olczyk, A.
Magiera, R.
Kabalyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/221299.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pneumatic probes
probe calibration
uncertainty of measurements
velocity measurements
Opis:
This paper presents the concept, design and experimental results of tests, in laboratory conditions, of a 2-port, space-saving pneumatic probe. The main features of the probe are a result of restrictions imposed by the functioning environment: a limited space for probe installation, the possibility of processing only two output signals and requirements for simplicity and reliability of the probe. A cylindrical shape of the probe tip is proposed as a general concept, similar to the classic, cylindrical, 3-port probe. The main difference arises in using only two pressure signals: one from the overpressure zone on the front side of the cylinder and another, from the underpressure zone on the back side. After performing an appropriate calibration procedure, it is possible to measure the flow velocity and correct the pressure difference obtained by means of a velocity coefficient kv. This paper also presents an analysis of the kv coefficient uncertainty to evaluate the quality of measurements.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 171-185
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Częstotliwościowa metoda pomiaru zespolonej przenikalności dielektrycznej materiałów porowatych przy zastosowaniu sond o różnej długości
Frequency method for the measurement of the porous materials complex dielectric permittivity using probes of different length
Autorzy:
Wilczek, A.
Skierucha, W.
Powiązania:
https://bibliotekanauki.pl/articles/156814.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
właściwości gleby
zespolona przenikalność dielektryczna
sonda Open-Ended
sonda dwuprętowa
soil properties
complex dielectric permittivity
Open-Ended probe
two-rod probe
Opis:
Celem pracy jest porównanie dwóch metod pomiaru zespolonej przenikalności dielektrycznej gleby. W pierwszej metodzie wykorzystywanej do pomiarów referencyjnych użyta została sonda Open-Ended. W drugiej metodzie do pomiarów zostały wykorzystane sondy dwuprętowe o różnej długości, przy pomocy których dokonywano pomiaru przenikalności dielektrycznej w tak dobranych częstotliwościach, aby można je było traktować jako elementy o parametrach skupionych. W pracy przedstawiono kalibrację sond dwuprętowych metodą używaną do kalibracji sond Open-Ended. Polega ona na pomiarach sond w stanach zwarcia, rozwarcia i po umieszczeniu ich w ośrodku o znanych właściwościach dielektrycznych. Po kalibracji dokonano pomiarów parametrów odbiciowych na próbkach trzech gleb w wybranych częstotliwościach. Wszystkie pomiary wykonywane były wektorowym analizatorem sieci pracującym w zakresie częstotliwości 20 kHz + 8 GHz. Obiektami badanymi były trzy gleby o różnym rozkładzie granulometrycznym oraz wilgotności. Ze względu na specyfikę pomiaru w pracy przedstawiono analizę dla jednej tylko gleby. Porównanie wyników pozwala sądzić, że stosowane metody wykazują się wysoką korelacją wyników w przypadku pomiarów obu składowych zespolonej przenikalności dielektrycznej.
The main aim of the study is comparision of two measurement methods of the complex dielectric permittivity of soils. The first one used an Open-Ended probe and it was a reference method. The other one used two-rod probes of different length. These probes measured reflection parameters soils in selected frequencies that enabled to treat the probes as elements of lumped parameters. The study presents calibration of the two-rod probes using the method applied in Open-Ended probes. Il consists of measurements in shorted and open states as well as the measurement in a medium of known dielectric properties. All measurements were done using a vector network analyzer of the frequency range 20 kHz 8 GHz. Three soils of various texture and moisture were the analysed objects. Due to specificity of the measurement the paper presents the analysis for only one soil. The comparison of the measured data shows that the real and imaginary parts of the complex dielectric permittivity measured by both methods are highly correlated.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 680-682
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic field measurements on PF - 1000 and PF - 3 facilities: current sheath structure and neutron scaling
Autorzy:
Krauz, V. I.
Mitrofanov, K. N.
Scholz, M.
Myalton, V. V.
Paduch, M.
Grabovskii, E. V.
Karpinski, L.
Koidan, V. S.
Vinogradov, V. P.
Vinogradova, Y. V.
Zielinska, E.
Powiązania:
https://bibliotekanauki.pl/articles/147526.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus (PF)
magnetic probe
current sheath
neutron scaling
Opis:
The comparative analysis of the magnetic field distribution, the dynamics and structure of the plasma current sheath, and the neutron yield scaling in two largest plasma focus facilities, PF-3 and PF-1000 is done. The power-low dependence of the neutron yield on the current in the imploding plasma sheath has been demonstrated experimentally. For the first time the presence of the Bz magnetic field components is experimentally shown.
Źródło:
Nukleonika; 2012, 57, 2; 201-204
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of individual dopants in singe-electron devices - a study by KFM observation and simulation
Autorzy:
Ligowski, M.
Moraru, D.
Miftahul, A.
Tarido, J. C.
Mizuno, T.
Tabe, M.
Jabłoński, R.
Powiązania:
https://bibliotekanauki.pl/articles/385159.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
single dopant
Kelvin Probe Force Microscope
single-electron transfer
Opis:
Single electron devices (SEDs) are candidates to become a keystone of future electronics. They are very attractive due to low power consumption, small size or high operating speed. It is even possible to assure compatibility with present CMOS technology when natural potential fluctuations introduced by dopant atoms are used to create quantum dots (QD). However, the main problem of this approach is due to the randomness of dopant distribution which is characteristic for conventional doping techniques. This leads to scattered characteristics of the devices, which precludes from using them in the circuits. In these work we approach the problem of correlating the distribution of QD's with the device characteristics. For that, we investigate with a Kelvin probe force microscope (KFM) the surface potential of Si nanodevice channel in order to understand the potential landscape. Results reveal the features ascribable to individual dopants. These findings are supported also by simulation results.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 130-133
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interstellar Probe - where is the “nose” of the heliosphere?
Autorzy:
Ratkiewicz, Romana
Baraniecka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2204241.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Centrum Badań Kosmicznych PAN
Tematy:
heliosphere
heliosphere model
interstellar probe
paradigm shift
space logistics
Opis:
In this paper are reviewed publications that were concerned about the discovery of the location of the heliopause “nose” by the Newtonian Approximation method and publications using the full three-dimensional magnetohydrodynamic simulations of the heliosphere that confirmed that discovery. Since we do not have a clear answer to the question of what the heliosphere looks like, in connection with the planned launch of the Interstellar Probe within this decade, there was a problem with deciding which direction to send it. The discovery of the movement of the “nose” of the heliopause depending on the direction of the interstellar magnetic field and the determination of the position of the “nose” is very important for this decision. Therefore, the purpose of the article is to answer the question of where is the “nose” of the heliopause. In the second part of the article, the possibility of changing the paradigm of scientific research projects related to interstellar missions (including those focused on the study of the heliosphere), among other things, by increasing the interdisciplinarity of research, is explored. As part of initiating such cooperation, the article develops social sciences themes related to the sustainable logistics of Interstellar Probe missions to increase public involvement in these projects.
Źródło:
Artificial Satellites. Journal of Planetary Geodesy; 2023, 58, 1; 14--28
2083-6104
Pojawia się w:
Artificial Satellites. Journal of Planetary Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the influence of calibration sphere parameters on the results of articulating probe head qualification
Autorzy:
Gruza, Maciej
Gąska, Adam
Gąska, Piotr
Harmatys, Wiktor
Sładek, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/103260.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
calibration
accuracy
przegubowa głowica sondy
kalibrowanie
precyzja
Opis:
The qualification of probe heads before the measurements performed with their usage is now a standard procedure. It is used for correction of probe head’s and measuring tip systematic errors. The calibration sphere, which is used for this process, should have adequately small form errors. However, it is not always possible to use a highly accurate spheres and it is a common practice to use a sphere that was provided by the manufacturer of the CMM for a long time. This is why, the authors have tried to answer the question about the impact of the calibration sphere inaccuracies on the results of probe head qualification process.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 2; 252-259
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja pomiarów termoparowej sondy psychrometrycznej za pomocą współczynnika temperaturowego
Correction of the thermocouple psychrometer probe measurements using temperature coefficient
Autorzy:
Guz, Ł.
Targosińska, E.
Powiązania:
https://bibliotekanauki.pl/articles/127077.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
termoparowa sonda psychrometryczna
korekcja pomiarów
thermocouple psychrometer probe
readings correction
Opis:
Termoparowe sondy psychrometryczne służą do pomiaru potencjału wody. Często wykorzystywane są w agrotechnice. Znajduję też inne zastosowanie, np. w szczególnych przypadkach mogą zostać zastosowane do oceny wilgotności porowatych materiałów budowlanych. Zastosowanie w budownictwie drastycznie ogranicza ich wąski zakres pomiarowy, który mieści się w granicach 94÷99% wilgotności względnej powietrza. Odczyt z sondy psychrometrycznej jest dodatkowo funkcją zależną od temperatury. Dlatego podczas analizy wyników pomiarów przeprowadzonych w odmiennych warunkach środowiskowych należy dokonać korekcji wyników ze względu na temperaturę pomiaru. Celem niniejszej pracy jest przeanalizowanie sposobu wykorzystania korekcji temperaturowej dla termoparowych sond psychrometrycznych PST-55 Wescor. Kalibracja sond została przeprowadzona w laboratoryjnym piecu Memmert VO500 w temperaturach 20÷35°C. Wzrost temperatury o 1°C następował w ciągu 10 minut, a następnie temperatura utrzymywana była przez 2 godziny. Jako roztwór kalibrujący został użyty wodny roztwór NaCl o stężeniach: 0,4 M, 0,7 M, 1,1 M oraz 1,4 M. Zaproponowany został uogólniony wzór Ψ = f(U,T), wyznaczający potencjał wody w funkcji napięcia sondy i temperatury.
Thermocouple psychrometer probes are used to water potential measurement. They are often used in agricultural applications. Psychrometric probes can be also used in other domains, such as moisture estimation in the porous building materials. Their application in building physics is strongly limited by narrow sensitivity range of the sensors, which, varies between 94÷99% of relative humidity of air in the porous material. Also, readouts of the thermocouple probes are function of the temperature during measurement. Therefore, in order to analyze of the results of measurements performed in the different environmental conditions it is necessary to correct the results regarding to temperature. The aim of this article is to assessment of the temperature correction method for the thermocouple psychrometer probes Wescor PST-55. Calibration of the probe was carried out in a laboratory oven Memmert VO500 at a temperature range between 20 and 35°C. Temperature increase of 1°C appeared during 10 min period and afterwards the temperature was maintained for 2 hours. For calibration there were used NaCl solutions at molar concentrations 0.4 M, 0.7 M, 1.1 M and 1.4 M. The general Ψ=f(U,T) equation was proposed, which allow to calculate water potential as a function depending on voltage and temperature.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 714-718
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TaqMan real-time PCR for detecting bovine viral diarrhea virus
Autorzy:
Liang, H.
Geng, J.
Bai, S.
Aimuguri, A.
Gong, Z.
Feng, R.
Shen, X.
Wei, S.
Powiązania:
https://bibliotekanauki.pl/articles/2087557.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bovine viral diarrhea virus
quantitative real time PCR
TaqMan probe
Źródło:
Polish Journal of Veterinary Sciences; 2019, 2; 405-413
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strain gauge tool probe for NC lathes
Narzędziowa sonda tensometryczna
Autorzy:
Szafarczyk, M.
Chrzanowski, J.
Gościniak, R.
Powiązania:
https://bibliotekanauki.pl/articles/256745.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
sonda tensometryczna
sonda narzędziowa
naturalne zużycie ostrza
pomiar
nóż tokarski
obrabiarka NC
tool probe
tool wear
tool wear measurement
strain gauge tool probe
NC lathes
Opis:
This paper shows the original probe which is protected by patent pending, and original method which is developed for direct wear measurement at the tip of the cutting edge in turning. The measurement is made automatically on a NC lathe by means of a special probe, which enables at the same time, to determine the X, Z co-ordinate of the edge. The modified probe has 4 strain gauges connected to full-bridge sensor. The sensor is placed on a flat surface which is mounted under angle 45 degree in relation to measurement direction. This probe has a possibility of 4-axis measurement, in X-, X+, Z-, Z+ direction of tool movement using only one full-bridge sensor. The results of laboratory tests show great promise in a number of industrial applications.
W artykule przedstawiono rolę sond narzędziowych stosowanych na obrabiarkach NC. Ukazano obecne sposoby określania współrzędnych i zużycia ostrza. Przedstawiono koncepcję nowej sondy bazującej na mostkach tensometrycznych, która umożliwia podczas jednego cyklu pomiarowego określenie współrzędnych i bezpośredni pomiar zużycia ostrza noża tokarskiego na tokarkach NC przy czterech kierunkach ruchu narzędzia.
Źródło:
Problemy Eksploatacji; 2006, 4; 161-170
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relationship between the impedance of a multi-pin probe and soil water content
Autorzy:
Sun, Y.
Kromer, K.H.
Powiązania:
https://bibliotekanauki.pl/articles/24149.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
soil water
relationship
dielectrical constant
impedance
multi-pin probe
water content
Źródło:
International Agrophysics; 2003, 17, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of Wall Velocity Measurements Using Photonic Doppler Velocimetry (PDV)
Autorzy:
Künzel, M.
Němec, O.
Pachman, J.
Powiązania:
https://bibliotekanauki.pl/articles/358399.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
bare fiber probe
Gurney constant
pentaerythritol tetranitrate
photonic Doppler velocimetry
Semtex
Opis:
The paper describes the measurement of cylindrical charge wall velocity profiles at various angles to the surface normal. The wall velocities were measured using simple zero generation photonic Doppler velocimetry (PDV). The detonation velocity was measured simultaneously using fiber optic probes coupled with a digital chronometer. The PDV probe angles were set in the range of -2° to 17° to the surface normal. Powdered pentaerythritol tetranitrate (PETN) and the PETN-based plastic-bonded explosive Semtex 1A were selected as the explosive materials in order to ensure reliable detonation under the measurement conditions. The explosive charges were confined in thin-walled aluminum tubes with an internal diameter of 16 mm and wall thickness of 2 mm. The results can be useful for the characterization of charge expansion phenomena and also for the optimization of cylinder test measurements using PDV. Gurney constants were determined for both explosives.
Źródło:
Central European Journal of Energetic Materials; 2015, 12, 1; 89-97
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dopant-Based Charge Sensing Utilizing P-I-N Nanojunction
Autorzy:
Nowak, R.
Jabłoński, R.
Powiązania:
https://bibliotekanauki.pl/articles/220915.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nanosensor
silicon
p-i-n junction
dopant
Kelvin Probe Force Microscope
Opis:
We studied lateral silicon p-i-n junctions, doped with phosphorus and boron, regarding charge sensing feasibility. In order to examine the detection capabilities and underlying mechanism, we used in a complementary way two measurement techniques. First, we employed a semiconductor parameter analyzer to measure I−V characteristics at a low temperature, for reverse and forward bias conditions. In both regimes, we systematically detected Random Telegraph Signal. Secondly, using a Low Temperature Kelvin Probe Force Microscope, we measured surface electronic potentials. Both p-i-n junction interfaces, p-i and i-n, were observed as regions of a dynamic behaviour, with characteristic time-dependent electronic potential fluctuations. Those fluctuations are due to single charge capture/emission events. We found analytically that the obtained data could be explained by a model of two-dimensional p-n junction and phosphorus-boron interaction at the edge of depletion region. The results of complementary measurements and analysis presented in this research, supported also by the previous reports, provide fundamental insight into the charge sensing mechanism utilizing emergence of individual dopants.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 391-399
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of different probing systems used in articulated arm coordinate measuring machines
Autorzy:
Brau, A.
Valenzuela, M.
Santolaria, J.
Aguilar, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/221100.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
articulated arm coordinate measuring machine
probing systems
self-centering active probe
Opis:
This paper presents a comparison of different techniques to capture nominal data for its use in later verification and kinematic parameter identification procedures for articulated arm coordinate measuring machines (AACMM). By using four different probing systems (passive spherical probe, active spherical probe, self-centering passive probe and self-centering active probe) the accuracy and repeatability of captured points has been evaluated by comparing these points to nominal points materialized by a ball-bar gauge distributed in several positions of the measurement volume. Then, by comparing these systems it is possible to characterize the influence of the force over the final results for each of the gauge and probing system configurations. The results with each of the systems studied show the advantages and original accuracy obtained by active probes, and thus their suitability in verification (active probes) and kinematic parameter identification (self-centering active probes) procedures.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 233-246
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model kinetyczny przetwornika pasywnych głowic skaningowych CMM
Kinetic model of CMM scanning passive probe transducer
Autorzy:
Krajewski, G.
Woźniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/155447.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica skanująca
współrzędnościowa maszyna pomiarowa
CMM
scanning probe
coordinate measuring machine
Opis:
W artykule przedstawiono analizę teoretyczną budowy przetwornika głowic skaningowych pasywnych stosowanych do pomiarów w technice współrzędnościowej. W efekcie podjętych prac autorzy otrzymali wstępny model dynamiczny pracy głowic, który może posłużć do kompensacji ich błędów powstałych na skutek zwiększenia prędkości pomiarowej.
Scanning probes, also known as measuring probes, are one of the most often used equipment of coordinate measuring machines (CMM) owing to ability of collecting large number of measuring points as well as taking fast measurements. High speed of measurements and high accuracy of the measuring system are two critical parameters deciding about the machine effectiveness. Dynamics is the most significant factor limiting the measurement accuracy. In most investigations of scanning CMM there is not separated the probing system performance from other sources of the machine errors, so the true error influenced by the probing system is not profoundly determined. This paper presents the scanning probe model regardless of the machine links. The worked out model allows for better understanding of the probing process with higher speed and optimising the measuring process. The future works will aim at proposing optimisation algorithms and applying them to the probing system as well as obtaining improvement in the accuracy.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 1, 1; 50-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa metoda generowania punktów offsetowych po skanowaniu CMM
The new method of generation of offset points after CMM scanning
Autorzy:
Filipowski, R.
Dąbrowski, L.
Zawora, J.
Powiązania:
https://bibliotekanauki.pl/articles/157835.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica pomiarowa
interpolacja
parametryzacja krzywej
probe head
interpolation
form of curve
Opis:
Skanowanie złożonych powierzchni na współrzędnościowej maszynie pomiarowej (CMM) jest szybką metodą ich pomiaru. Współrzędne punktów środka kulki głowicy pomiarowej w układzie współrzędnych kartezjańskich są zapisywane do zbioru danych w komputerze (PC). Każdy punkt pomiarowy jest określony przez wektor pozycyjny w prostokątnym układzie oraz parametr zmieniający się od zera do jedności. Przez punkty pomiarowe prowadzi się krzywe parametryczne Fergusona (splajn) a następnie przy ich pomocy generuje się punkty offsetowe. Zastosowane interpolacyjne funkcje Fergusona pozwalają uzyskać dobrą dokładność obliczenia położenia punktów offsetowych powierzchni mierzonych.
This paper presents a new method generating offset points after scanning process of cylindrical surface on the CMM, were in to the file of the connected PC using part coordinate system. The cartesian coordinates of points are transformed in parameter coordinates. By the processing of scanning data, the distance between points are made nearly equal. That way some points positioned too closely were eliminated form the calculation process. This closeness was caused by variation in CMM scanning speed. In the last step, the processed points with parameter coordinates were connected to the Ferguson function, thus enabling determining the position of the offset points. The parameter coordinates of points and the third degree curve (Ferguson curve) lead to very good accuracy of reverse engineering process for cylindrical surfaces.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 11, 11; 5-8
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie błędów głowicy pomiarowej z zastosowaniem metody Monte Carlo
Modeling of probing system errors by use of Monte Carlo method
Autorzy:
Sładek, J.
Juras, B.,
Krawczyk, M.
Gąska, A.
Powiązania:
https://bibliotekanauki.pl/articles/152502.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
głowica pomiarowa
niepewność
metoda Monte Carlo
probe head
uncertainty
Monte Carlo
Opis:
W obecnych czasach, gdy nowoczesne techniki wytwarzania umożliwiają produkcję części z coraz to większą dokładnością, a tolerancje ich wykonania stają się coraz węższe, pojawia się potrzeba bardzo dokładnego wyznaczania niepewności pomiarów. Ważne jest również, aby proces estymacji niepewności stawał się jak najszybszy. Z tego powodu najlepiej rozwinięte laboratoria metrologiczne starają się stworzyć wirtualne modele WMP, które są w stanie wyznaczyć niepewność pomiarów w czasie quasi-rzeczywistym. Ten artykuł przedstawia sposób modelowania błędów głowicy pomiarowej z wykorzystaniem metody Monte Carlo. Błędy głowicy pomiarowej stanowią znaczną część całkowitych błędów maszyny pomiarowej, a zaprezentowany model może zostać wykorzystany jako jeden z modułów wirtualnej WMP.
Nowadays, when the manufacturing technologies are getting more and more precise, and the tolerances are getting narrower, there is a need of expressing the uncertainty of measurement at the really high level. It is also important to make the uncertainty estimation as quick as possible. This is why the most developed metrological laboratories are trying to create the virtual CMM models that can handle uncertainty evaluation in quasi-real time. This paper shows how to model, with use of the Monte Carlo method, the probing system errors which are one of the most significant errors of CMMs. The presented model can then be used as a module of virtual CMM. Paragraph 2 presents the theoretical basis of probing system operation. It also points out the factors causing probing system errors. The mentioned model of probe head errors is presented in Paragraph 3. Paragraph 4 gives the results of the measurements and simulations that have been performed to show functionality and correctness of the model. Conclusions and areas of development are presented in Paragraph 5.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 8, 8; 946-949
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie sondy lambda w systemie Motronic
Use of service knowledge in the diagnosis of network CAN
Autorzy:
Duer, S.
Warczyk, S.
Powiązania:
https://bibliotekanauki.pl/articles/314848.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
sterownik silnika
sonda lambda
system Motronic
motor controller unit
lambda probe
Opis:
W pracy przedstawiono problematykę badania układu sondy lambdda w systemie Motronic. Celem prowadzonych badań diagnostycznych jest określenie stanu sprawności układu sondy lambdda. Sonda lambdda ma duży wpływ z jednej strony na optymalne zużycie paliwa, a z drugiej strony na czystość spalin. Podstawowe badanie przy użyciu typowych metod i typowych narzędzi pomiarowych jest nie wystarczające. Pełniejszym badanie w układzie sony lambdda możliwym do wykonania „map roboczych”. W tym celu dokonuje się pomiarów sygnałów sterujących w układzie wtrysku paliwa jest czas wtrysku paliwa. Na podstawie tych pomiarów wykreślane są „mapy robocze”. Znajomość „map roboczych” w dalszym etapie badań są jest podstawą do analizy uzyskanych wyników pomiarowych z danymi zawartymi w bazach serwisowych np. bazie serwisowej „AutoData”. Sposób diagnostyki polega głównie na sprawdzeniu poprawności parametrów sygnałów badanych z ich sygnałami wzorcowymi zawartymi w bazie serwisowej.
The issues are presented in the study of the probe lambdda system Motronic. The aim of the study is to determine the diagnostic performance status of the probe lambdda. Poll lambdda has a big influence on the one hand for optimum fuel consumption and on the other hand, the purity of exhaust gases. The basic test using conventional methods and common tools of measurement is not sufficient. Fuller examination system lambdda possible to do "map work." For this purpose, the measurement control signals to the fuel injection system is a fuel injection time. On the basis of these measurements are plotted "maps working". Knowledge of the "working map" in the next stage of research are the basis for the analysis of the results from the measurement data contained in databases such service. Based service "Autodata". Method for the diagnosis relies mainly on checking the correctness of signal parameters studied with the calibrating signals contained in the database service.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 7-8; 153-158
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu położenia punktu poboru spalin na wartość stężenia związków szkodliwych w strudze gazów wylotowych silnika odrzutowego
The impact assessment of probe positioning for the exhaust gases concentration of the jet engine
Autorzy:
Markowski, J.
Pielecha, J.
Jasiński, R.
Ślusarz, G.
Wirkowski, P.
Benedict, P.
Powiązania:
https://bibliotekanauki.pl/articles/316559.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
emisja spalin
silnik odrzutowy
sonda pomiarowa
emission exhausts
jet engine
probe
Opis:
Emisja związków szkodliwych zawartych w spalinach zależy w od warunków eksploatacji silnika oraz jego stanu technicznego. W związku z tym działalność ustawodawcza ukierunkowana jest na wprowadzanie nowych procedur diagnostycznych i badawczych. Preferowana jest metoda z wykorzystaniem wielootworowych sond pomiarowych do wielopunktowego poboru spalin z całego przekroju strugi wypływających spalin. Taki pobór próbki spalin wydaje się obarczony błędem uśrednienia i rozcieńczenia pobranej próbki gazu już na samym początku drogi pomiarowej. Dlatego w artykule przedstawiono pomiary związane ze zmianą stężenia związków szkodliwych w spalinach w zależności od odległości od osi strugi. Podkreślono wady metody i przedstawiono propozycję pomiaru jednopunktowego.
Emission of harmful compounds in the exhaust gases depends on the operating conditions of the engine and its technical condition. Therefore, the legislative activity is focused on the introduction of new diagnostic and research procedures. The preferred method is using probes with plurality of holes for multi-gas sampling from the entire cross-section of exhaust stream. This method appears to vitiated by an error caused by averaging dilution and sampling gas from the very beginning of the measurement path. The results of measurements contained in the article are related to changes in the concentration of harmful substances in exhaust gases depending on the distance from the axis of the jet. In the article the disadvantages of this the methods were highlighted and the single-point measurement method was proposed.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 1195-1198
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of geometric precision of plastic components made by subtractive and additive methods
Autorzy:
Fudali, P.
Witkowski, W.
Wydrzyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/101936.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rapid prototyping
fused deposition modelling
machining
touch probe measurement
points cloud
Opis:
The paper presents information on manufacturing processes of plastic components. Basic subtractive and additive methods are described. There were also manufactured elements of fan housing by using this two types of methods. Then, the elements were measured using a touch probe. The obtained results were analyzed, on which a comparison of components’ geometric accuracy was performed.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 19; 36-40
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Online and FREE access to plasma physics experiments
Autorzy:
Mendes Rossa, Pedro A.
Kuriščák, Pavel
Silva, João N.
Veiga, José
Loureiro, João P. S.
Oliveira, João
Hachmeister, Daniel
Fernandes, Horácio
Powiązania:
https://bibliotekanauki.pl/articles/2202569.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
educational technology
e-lab
electromagnetic cavity
langmuir probe
remote controlled experiment
Opis:
Remote controlled laboratories had a great push during the COVID-19 pandemic. In fact, they were already out there but lacking in visibility. This external trigger pushed the academy to face a global challenge to start offering remote experiments more consistently and maturely. Instituto Superior Técnico (IST) has been offering several remote experiments since 2000 but with the need for an update due to technological aging. As such, the framework for remote experiments in education (FREE) was created based on new web technologies. In addition to the most diverse experiments that had already been developed, FREE includes two experiments that aimed at advanced-level physics students: the Langmuir probe and the electromagnetic (EM) cavity. Both allow users to configure the various parameters and to access the results in real time or check back later. All this access is done using a browser (on a PC or mobile phone) without the need to install additional software. The results of an experimental execution are stored in a database and are downloadable, allowing users to do various analyses and to determine the corresponding plasma density and temperature. In this paper, we will introduce how FREE was used in the implementation of both experiments and give an insight into their didactic approach, such as: (i) how to perform an experimental execution, (ii) the typical data set obtained with, and (iii) the corresponding analysis necessary for the user to retrieve information from it.
Źródło:
Nukleonika; 2023, 68, 1; 37--46
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of reliable transcript levels of annotated genes on the basis of multiple probe-sets in Affymetrix microarrays
Autorzy:
Jaksik, Roman
Polańska, Joanna
Herok, Robert
Rzeszowska-Wolny, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1040584.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
multiple probe-sets
Affymetrix microarrays
transcript profiles
outlier detection
NucleoDix computer program
Opis:
Microarray methods have become a basic tool in studies of global gene expression and changes in transcript levels. Affymetrix microarrays from the HGU133 series contain multiple probe-sets complementary to the same gene (4742 genes are represented by more than one probe-set in a microarray HGU133A). Individual probe-sets annotated to the same gene often show different hybridization signals and even opposite trends, which may result from some of them matching transcripts of more than one gene and from the existence of different splice-variant transcripts. Existing methods that redefine probe-sets and develop custom probe-set definitions use mathematical tools such as Matlab or the R statistical environment with the Bioconductor package (Gentleman et al., 2004, Genome Biol. 5: 280) and thus are directed to researchers with a good knowledge of bioinformatics. We propose here a new approach based on the principle that a probe-set which hybridizes to more than one transcript can be recognized because it produces a signal significantly different from others assigned to the particular gene, allowing it to be detected as an outlier in the group and eliminated from subsequent analyses. A simple freeware application has been developed (available at www.bioinformatics.aei.polsl.pl) that detects and removes outlying probe-sets and calculates average signal values for individual genes using the latest annotation database provided by Affymetrix. We illustrate this procedure using microarray data from our experiments aiming to study changes of transcription profile induced by ionizing radiation in human cells.
Źródło:
Acta Biochimica Polonica; 2009, 56, 2; 271-277
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Digitally Controlled Model of an Active Ultrasonic Transducer Matrix for Projection Imaging of Biological Media
Autorzy:
Opieliński, K. J.
Gudra, T.
Pruchnicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/178008.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic projection
active ultrasonic transducer matrix
multielement ultrasonic probe
electrode attachment optimisation
Opis:
The following work presents the idea of constructing a digitally controlled active piezoceramic transducer matrix for ultrasonic projection imaging of biological media in a similar way as in case of roentgenography (RTG). Multielement ultrasonic probes in the form of flat matrices of elementary piezoceramic transducers require attaching a large number of electrodes in order to activate the individual transducers. This paper presents the idea of minimising the number of transducer connections in an active row-column matrix system. This idea was verified by designing a model of a matrix consisting of 16 ultrasonic transducers with electrode attachments optimised by means of electronic switches in rows and columns and miniature transistor switches in the nodes of the matrix allowing to activate selected transducers. The results of measurements and simulations of parameters of the designed matrix show that it is suitable to be used in projection imaging of biological media as a sending probe. In to use the matrix as a universal sending or receiving probe, it was suggested to add further switches that would eliminate the undesired effect of crosstalks in case of switches used for toggling the transducers in the nodes of the matrix.
Źródło:
Archives of Acoustics; 2010, 35, 1; 75-90
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure and local parameters of self-compressed plasma streams in external magnetic field
Autorzy:
Volkova, Yuliia
Solyakov, Dmytro
Marchenko, Anna
Chebotarev, Volodymyr
Garkusha, Igor
Makhlai, Vadym
Ladygina, Maryna
Tetyana, Merenkova
Yeliseyev, Dmytro
Petrov, Yurii
Staltsov, Valerii
Powiązania:
https://bibliotekanauki.pl/articles/2202565.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
current sheet
electric probe
electron temperature
drift velocity
pinching discharge
plasma accelerators
Opis:
The influence of the external axial magnetic field on pinching plasma flows generated by a magnetoplasma compressor (MPC) has been studied using magnetic and electric probes. In the presence of an external magnetic field, temperature measurements show two groups of electrons with different temperatures near the plasma stream core. The external magnetic field leads to a noticeable increase in the electric current in the plasma stream, electron temperature, and the formation of the current-sheet-like structure observed in the MPC for the first time.
Źródło:
Nukleonika; 2023, 68, 1; 3--9
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fluorescencyjne nanolipopolimersomy jako bezpieczne kontrasty w diagnostyce medycznej
Nanolipopolymersomes with a fluorescent wall as imaging agents in medical diagnostics
Autorzy:
Sierant, M.
Miksa, B.
Powiązania:
https://bibliotekanauki.pl/articles/278229.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Inżynierii Materiałów Polimerowych i Barwników
Tematy:
diagnostyka medyczna
kontrast
nanolipopolimersomy
kapsułka polimerowa
kapsułka fluorescencyjna
sonda fluorescencyjna
sonda polimerowa
in vitro
medical diagnostics
imaging agent
nanolipopolymersomes
polymer capsule
fluorescence capsule
fluorescence probe
polymer probe
Opis:
Przedmiotem badań była synteza biokompatybilnych kapsułek polimerowych, które mogłyby spełniać rolę sondy fluorescencyjnej wykorzystywanej jako kontrasty w żywych komórkach. Otrzymaliśmy nanolipopolimersomy otoczone fluorescencyjną powłoką z usieciowanego polistyrenu z dodatkiem kumaryny 6. Wykazaliśmy na przykładzie barwników (Procion red, Procion blue, Lucifer yellow), że możliwa jest enkapsulacja hydrofilowych związków we wnętrzu trwałych, polimerowych pęcherzyków. Opracowana przez nas uniwersalna metoda syntezy stabilnych nanokapsułek wykorzystujących nietrwałe struktury liposomów może znaleźć szerokie zastosowanie w diagnostyce medycznej do transportu wielu substancji aktywnych oraz monitorowania ich lokalizacji w komórkach.
In our research we synthesized biocompatible probes for developing a stable macromolecule imaging system using nanolipopolymersomes in living cells. We prepared polymer vesicles with a fluorescent wall surrounded by on outer phospholipids shell suitable for dual detection (spectrophotometric and fluorescence). We developed highly fluorescent coumarinated poly(styrene-co-divinylbenzene) capsules with encapsulated hydrophilic dyes (Procion Red, Procion blue, Lucifer yellow). Our method of synthesis novel fluorescent hybrid materials can help in medical diagnostics, which can be uses in studies of the transport routs in living cells.
Źródło:
Przetwórstwo Tworzyw; 2014, [R.] 20, nr 1 (157), 1 (157); 88-91
1429-0472
Pojawia się w:
Przetwórstwo Tworzyw
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narrow Beam Ultrasonic Transducer Matrix Model for Projection Imaging of Biological Media
Autorzy:
Opieliński, K. J.
Gudra, T.
Pruchnicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/178004.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic projection
directional ultrasonic transducer matrix
multielement ultrasonic probe
electrode attachment optimisation
Opis:
The following paper presents an idea of minimising the number of connections of individual piezoelectric transducers in a row-column multielement passive matrix system used for imaging of biological media structure by means of ultrasonic projection. It allows to achieve significant directivity with acceptable input impedance decrease. This concept was verified by designing a model of a passive ultrasonic matrix consisting of 16 elementary piezoceramic transducers, with electrode attachments optimised by means of electronic switches in rows and columns. Distributions of acoustic field generated by the constructed matrix model in water and results of the calculations conformed well.
Źródło:
Archives of Acoustics; 2010, 35, 1; 91-109
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odkształcenia cieplne a niedokładność pomiaru sondą przedmiotową
Inaccuracy of measurements by inspection probe in relation to thermal deformations
Autorzy:
Jacniacka, E.
Semotiuk, L.
Powiązania:
https://bibliotekanauki.pl/articles/152586.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sonda przedmiotowa
niepewność pomiaru
odkształcenia cieplne
inspection probe
uncertainty
measurement
thermal deformation
Opis:
Sondy przedmiotowe coraz częściej są standardowym wyposażeniem obrabiarek CNC. Wykorzystywane są do pomiaru wymiarów pomiędzy zabiegami technologicznymi oraz do kontroli po zakończeniu obróbki. W procesach obróbki skrawaniem generowane są znaczne ilości ciepła., które kumulowane w przedmiocie obrabianym, powoduje wzrost jego temperatury i co za tym idzie zmianę wymiarów. W pracy zaprezentowano wyniki pomiaru sondą długości OMP 60 przedmiotów frezowanych wykonanych ze stali C45 i stopu aluminium 2017 A. Przeprowadzony eksperyment pokazał, że odkształcenia wywołane ciepłem generowanym w strefie skrawania są znaczące i nie można ich pominąć podczas pomiaru sondami przedmiotowymi.
Inspection probes are used to measure dimensions between technological operations and to control after completing the machining. Machining generates significant amount of heat which is accumu-lated in a machined object causing change of the object dimensions. In this paper there is discussed the influence of thermal deformation on the accuracy of measurements taken by an inspection probe. In Section 2 there are presented the most important sources of measurement errors and methods for assessment of the measurement accuracy by means of the inspection probe. The study included measurements taken by the inspection probe after machining at given intervals. Two very popular materials, steel C45 and aluminium alloy 2017A, were chosen. In-cut milling with and without cooling with cutting fluid was used as a method of machining. In Fig. 1 the object with marked measurement points is presented. Fig. 2 shows the object fixed in workspace of the machining center. The results of measurements made with use of the inspection probe were compared with those obtained from CMM measurements in 20°C. Elongation ΔL was calculated as a difference between the measurement by the inspection probe OMP 60 and CMM measurement. In Tables 4-7 the average elongation as a function of time from the end of machining to the beginning of measurements is given. Figs. 3 and 4 show its graphic representation.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 9, 9; 985-988
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DNA fingerprints generated by R.18.1 DNA probe in two stocks of chickens: Green Legged Patridgenous [GLP] and Rhode Island Red [RIR]
Autorzy:
Rosochacki, S J
Hillel, J
Jaszczak, K
Zawadzka, M
Powiązania:
https://bibliotekanauki.pl/articles/2046824.pdf
Data publikacji:
1997
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-locus DNA probe
hybridization
animal breeding
poultry
molecular marker
DNA
chicken
Opis:
Hybridization of a multi-locus DNA probe, R 18.1, to genomic DNA from poultry showed a highly polymorphic fingerprint pattern. The detected DNA fingerprints are individually specific and differ between Green Legged Patridgenous (GLP) and Rhode Island Red (RIR) stock of chickens. The average numbers of detected bands in RIR were 18.68 and in GLP - 15.33, but the average band sharing levels were 0.619 and 0.431, respectively. The level of polymorphism may be connected possibly with a higher level of inbreeding in the examined stock of chicken.
Źródło:
Journal of Applied Genetics; 1997, 38, 2; 173-178
1234-1983
Pojawia się w:
Journal of Applied Genetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczenie stanów energetycznych powierzchni zgłębnika żołądkowego po wybranych procesach starzenia materiału
Determination of energetic states of nasalgastric tube surface of after selected material aging processes
Autorzy:
Chrobak, Aleksandra
Cieślik, Magdalena
Jaśko, Klaudia
Kuras, Ilona
Łagan, Sylwia
Powiązania:
https://bibliotekanauki.pl/articles/2201477.pdf
Data publikacji:
2019
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
starzenie materiału
sonda żołądkowa
hydrofilowość
hydrofobowość
material ageing
gastric probe
hydrophilicity
hydrophobicity
Opis:
Celem pracy była ocena wpływu procesu starzenia zgłębnika żołądkowego na właściwości powierzchni określona w oparciu o pomiary kątów zwilżania. Oznaczono poziom chłonności materiału pod wpływem działania środowiska wodnego (woda: 23ºC/24h oraz 100º/h, 0,9% roztwór NaCl: 37ºC/48h, roztwór Nestle Health Science Isosource Energy: 37ºC/48h). Zidentyfikowano swobodną energię powierzchniową oraz jej składowe wykorzystując dwa modele analityczne (Owensa-Wendta oraz van Ossa-Chauhury-Gooda). W rezultacie przyspieszonego starzenia ujawniono zmiany właściwości powierzchni zgłębnika.
The aim of this work was to assess the influence of the stomach tube aging process on surface properties determined based on measurements of contact angles. The level of absorbency of the material under the influence of the water environment was determined (water: 23ºC / 24h and 100º / h, 0.9% NaCl solution: 37ºC / 48h, Nestle Health Science Isosource Energy: 37ºC/48h). The surface free energy and its components were identified using two analytical models (Owens-Wendt and van Oss-Chauhury-Good). As a result of aging accelerated aging, changes in the surface properties of the stomach tubes were revealed.
Źródło:
Aktualne Problemy Biomechaniki; 2019, 17; 19--25
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Molecular probes for detection of wheat chromosomal fragments in rye.
Autorzy:
Rafalski, Andrzej
Wiśniewska, Iwona
Sikora, Teresa
Łapiński, Bogusław
Powiązania:
https://bibliotekanauki.pl/articles/2198780.pdf
Data publikacji:
2000-12-20
Wydawca:
Instytut Hodowli i Aklimatyzacji Roślin
Tematy:
introgression
PCR
rye
Southern blotting
Triticum durum probe
wheat
wheat specific probes
Opis:
Twelve DNA fragments amplified on templates of Triticum urartu, Aegilops speltoides and Aegilops squarrosa were separated, reamplified and used as digoxigenin-labelled probes. The species and genome specificity of probes was evaluated by Southern dot-blot hybridisation to Triticum durum, the donors of wheat genomes, rye and rye with introgressed wheat chromosome fragments. In comparison to labelled genomic DNA of T. durum, the probes obtained by labelling PCR-amplified fragments exhibited higher specificity to wheat genomes. Under the applied hybridisation conditions all probes showed different degree of cross-hybridisation to rye DNA. Some probes indicated quantitative difference in their specificity to wheat genomes, but generally the intensity of hybridisation to the genomes A, S and D was independent of the origin of an amplified fragment. Selected probes, used in dot-blot hybridisation system together with genomic DNA of T. durum, may increase the sensitivity of screening wheat chromosomal fragments introgressed to rye.
Źródło:
Plant Breeding and Seed Science; 2000, 44; 27-37
1429-3862
2083-599X
Pojawia się w:
Plant Breeding and Seed Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Formation and Thermodynamic Analyses of Inclusions in Ti-Containing Steel Weld Metals with Different Al Contents
Autorzy:
Wang, Bingxin
Jiang, Yingtian
Powiązania:
https://bibliotekanauki.pl/articles/2049426.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermodynamic calculation
electron probe micro-analyzer
oxide inclusion
aluminium content
phase diagram
Opis:
Ti-containing steel weld metals with Al contents of 0.01-0.085% were prepared. The effects of Al contents on the inclusions evolution were investigated by means of thermodynamic calculations coupled with electron probe micro-analyses and transmission electron microscopy. The results show that the inclusions in the 0.01% Al weld metal are mainly composed of ilmenite withsome amounts of (Mn-Si-Al)-oxide and titanial_spinel. When Al content is increased up to 0.035%, a more amount of corundum and a small amount of pseudobrookite are formed. In 0.085% Al weld metal, the (Mn-Si-Al)-oxide disappears completely, and the inclusions contain a substantial amount of corundum, in addition to a minimal amount of pseudobrookite. Ti3O5, MnTi2O4 and MnTiO3 are the primary constituents of pseudobrookite, titanial_spinel and ilmenite, respectively. Titanial_spinel and ilmenite have higher amounts of Mn, but lower Ti levels compared with pseudobrookite. In the case of presence of a considerable amountsof titanial_spinel and ilmenite, Mn-depleted zone is formed in matrix around the inclusions.
Źródło:
Archives of Metallurgy and Materials; 2021, 66, 1; 171-180
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie dwuwymiarowej niedokładności pomiaru wewnątrzobrabiarkowego system pomiarowego z zastosowaniem sondy OMP60
Determination of two-dimensional measurement uncertainty of measurement system inside machine tool with use of inspection probe OMP60
Autorzy:
Jacniacka, E.
Semotiuk, L.
Babkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/275816.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
niepewność pomiaru
sonda przedmiotowa
obrabiarka CNC
uncertainty
inspection probe
CNC machine tool
Opis:
Sondy przedmiotowe coraz częściej są standardowym wyposażeniem obrabiarek CNC. Wykorzystywane są dopomiaru wymiarów geometrycznych między zabiegami technologicznymi oraz do kontroli po zakończeniu obróbki. W artykule przedstawiono i porównano wyniki wyznaczania dwuwymiarowej niedokładności pomiaru z wykorzystaniem płytek wzorcowych i pierścienia wzorcowego.
Inspection probes are becoming a standard equipment of CNC machine tools. They are used to measure dimensions between technological operations, and to control after machining is completed. This paper presents results of determining two-dimensional uncertainty with use of gauge blocks and gauge rings.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 10; 68-73
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photoproduction of organic peroxides on the donor side of photosystem II after destruction of the water-oxidizing complex
Autorzy:
Khorobrykh, A.
Khorobrykh, S.
Yanykin, D.
Ivanov, B.
Klimov, V.
Mano, J.
Powiązania:
https://bibliotekanauki.pl/articles/79884.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
conference
manganese
photosystem II
water oxidizing complex
photooxidation
organic molecule
fluorescence probe
photoinhibition
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2013, 94, 2
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary rozkładu amplitudy i fazy akustycznej fali powierzchniowej w krysztale NdCa4O(BO3)3 z wykorzystaniem sondy elektrycznej
Measurements of the amplitude and the phase distribution of a surface acoustic wave in a NdCa4O(BO3)3 crystal using an electric probe
Autorzy:
Brzozowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/192168.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
sonda
sonda elektryczna
kryształ piezoelektryczny
AFP
electric probe
piezoelectric crystal
surface acoustic wave
Opis:
Skonstruowano sondę do pomiaru rozkładu amplitudy i fazy akustycznej fali powierzchniowej (AFP) w płaszczyźnie propagacji. Elektrodę sondującą wykonano w postaci wolframowej igły przesuwanej po polerowanej powierzchni kryształu piezoelektrycznego. Do odczytu wzmocnionego sygnału z elektrody sondującej wykorzystano analizator sieci. Za pomocą sondy zbadano rozkłady amplitudy i fazy w wiązce AFP dla wybranych orientacji kryształu NdCa4O(BO3)3.
An electric probe for measuring the amplitude and the phase distribution of a surface acoustic wave (SAW) in a propagation plane was developed. The probing electrode was prepared in a form of a tungsten pin sliding on a polished surface of a piezoelectric crystal. For reading the electric signal from the electrode, a network analyser was used. The amplitude and the phase distributions in an AFP beam were measured for chosen orientations of a NdCa4O(BO3)3, crystal.
Źródło:
Materiały Elektroniczne; 2012, T. 40, nr 1, 1; 14-18
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface forces in chemical mechanical planarization and semiconductor wafer cleaning systems
Autorzy:
Hupka, Lukasz
Nalaskowski, Jakub
Miller, Jan D.
Hupka, Jan
Powiązania:
https://bibliotekanauki.pl/articles/1853722.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
chemical mechanical planarization
CMP
surface chemistry phenomena
colloidal probe
atomic force microscopy
AFM
Opis:
Superior uniformity and local planarity of semiconductor wafers in the chemical mechanical planarization (CMP) process as well as efficient post-CMP cleaning is controlled by surface chemistry phenomena. The AFM colloidal probe technique was used to demonstrate surface forces which are of special significance to CMP and post-CMP cleaning. Examples of ways to manipulate those interactions are provided, and the benefits to CMP processes and post-CMP cleaning are discussed.
Źródło:
Wiadomości Chemiczne; 2021, 75, 9-10; 1229-1240
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental methods for determining uncertainty of measurement using inspection probes
Doświadczalne metody wyznaczania niepewności pomiaru sondami przedmiotowymi
Autorzy:
Jacniacka, E.
Semotiuk, L.
Powiązania:
https://bibliotekanauki.pl/articles/1366180.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
niepewność pomiaru
obrabiarki CNC
sonda przedmiotowa
uncertainty of measurement
CNC machines
inspection probe
Opis:
The paper presents the results of determining uncertainty of measurement using an inspection probe on numerically controlled vertical milling machines. To do the measurements, methods developed for coordinate measuring machines were employed. For the measurement system consisting of a vertical machining center FV-580A and OMP60 touch probe, the uncertainty of measurement was determined for the coordinates of the point, one-dimensional length measurement, two-dimensional length measurement, as well as for length measurement using multiple measurement strategies.
W pracy przedstawiono wyniki wyznaczania niepewności pomiaru sondą przedmiotową na frezarkach pionowych sterowanych numerycznie. Do pomiarów zaadaptowano metody opracowane dla współrzędnościowych maszyn pomiarowych. Dla systemu pomiarowego składającego się z centrum obróbkowego FV580A i sondy OMP 60 wyznaczono niepewność pomiaru: współrzędnych punktu, jednowymiarowego pomiaru długości, dwuwymiarowego pomiaru długości oraz pomiaru długości z zastosowaniem przedmiotu niekalibrowanego.
Źródło:
Eksploatacja i Niezawodność; 2013, 15, 3; 246-252
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania porównawcze pomiarów wykonywanych za pomocą współrzędnościowego ramienia pomiarowego wyposażonego w głowicę sztywną i impulsową
Comparative studies of measurements made by a coordinate measuring arm equipped with hard and trigger probes
Autorzy:
Rak, M.
Ratajczyk, E.
Kowaluk, T.
Powiązania:
https://bibliotekanauki.pl/articles/153541.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współrzędnościowe ramię pomiarowe
głowica (sonda) pomiarowa
coordinate measuring arm (portable CMM)
measuring probe
Opis:
Przedstawiona jest ocena dokładności pomiarów przeprowadzonych głowicą sztywną i przełączającą za pomocą współrzędnościowego ramienia pomiarowego [1]. Ramiona współrzędnościowe są mobilnymi ręcznymi przyrządami pomiarowymi. W celu lokalizacji punktów pomiarowych wyposażone są najczęściej w głowice sztywne. Dzięki użyciu w jednym ramieniu zarówno głowicy sztywnej jak i przełączającej możliwe było porównanie ich ze sobą. Badania eksperymentalne wykonano na podstawie wybranych wymiarów elementu w postaci kostki szkoleniowej. Otrzymane wyniki badań pozwalają ocenić stopień dokładności przy stosowaniu poszczególnych rodzajów głowic.
The purpose of the paper is to assess the accuracy of measurements made with hard and trigger probes on a coordinate measuring arm. In the case of hard heads the measuring force is variable and depends on an operator who decides on appearance of a contact of the stylus tip with the measured surface, while in the case of trigger probes the contact of the tip with the measured surface is independent of shaft swings, breaking the electrical contact inside the head due to deflection of the stylus and breaking the electrical contact inside the head. The study was conducted with use of the arm Metris – Nikon MCA II shown in Fig. 1. Arms are manual measuring devices equipped, in most cases, with hard probes. Through the use of hard and trigger probes in one arm, it is possible to compare two heads. The TP20 kinematic touch-trigger probe with an SF module (standard force) was used as a trigger head. The paper presents a brief description of coordinate measurements as well as construction and working principle of coordinate measuring arms. In Fig. 3 there is shown a CAD model of the training cube used as a test part. The tests were made on the basis of measurements of four cylindrical holes with different diameters. The obtained results for two probes were compared with each other. It was analyzed how the range of results for different diameters for hard and trigger probes changed. The results show the influence of other factors (besides the measuring force). To show the influence of the measuring force, tests on a cube made of different materials were also performed.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 456-458
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Redukowanie czasu obliczeń transformaty Hougha z wykorzystaniem preselekcji implementowane na GPGPU
Reducing the computation time of the Hough Transform implemented on GPGPU using preselection of circles
Autorzy:
Mazurek, P.
Powiązania:
https://bibliotekanauki.pl/articles/155295.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformata Hougha
próbnik światła
pomiary oświetlenia
GPGPU
Hough transform
light probe
light measurements
Opis:
W artykule przedstawiono algorytm rzadkiego próbkowania okręgu dla transformaty Hougha, w celu preselekcji okręgów do dalszego przetwarzania. Rozwiązanie pozwala na skrócenie czasu obliczeń, rzędu dwóch razy dla implementacji z wykorzystaniem programowanej karty graficznej (GPGPU). Może ono być zastosowywane do wykrycia jednokolorowej kryzy wokół lustra sferycznego lub półsferycznego służącego do pomiaru oświetlenia. Dzięki temu można analizować obraz wideo zawierający pomiary z różnych obszarów.
The Hough Transform (HT) is a very powerful algorithm for the detection of shapes. It is used for the detection of the flange of a light probe (Fig. 1). GPGPU processing is necessary for HT computation. The proposed algorithm (Fig. 4) is based on the preselection of circles for further computation (Fig. 3). Selection of the circles based on a limited set of pixel samples allows reduction of the processing time up to two times. The reduction is dependent on the image content, but the test shows that the influence of the number of the tested radiuses is less. About one second of the processing time is necessary, so larger images need tens of seconds for computation (Fig. 5). This algorithm uses exhaustive search over all positions and radiuses. One of the interesting applications of the HT is the estimation of the position and diameter of a circle related to the flange of a light probe [2, 3]. Light probes are used for computer graphics applications and they allow application of the real world measurements of light using the Image Based Lighting (IBL) technique. The GPGPU implementation use CUDA based code (CUDA v4.0) [10,11] and 16x8 organization of threads is assumed. The technique proposed for the time and spatial synchronization of the multiple threads for more synchronous read operation from a global memory is applied [7]. The global memory is large and slow, so a GPGPU-global memory interface is the main bottleneck of the system. Synchronization of accesses allows coalescence read operations.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 11, 11; 1171-1173
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel deep penetrating eddy current probe based on phase shifted fields and its application to inspection of defects
Autorzy:
Wu, Meixian
Zhang, Dongli
Wang, Chuanglong
Powiązania:
https://bibliotekanauki.pl/articles/221582.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
skin effect
penetration depth
austenitic stainless steel
eddy current probe
phase shifted fields
Opis:
Due to the skin effect of eddy currents, the depth of cracks which can be detected by the traditional eddy current probe is very limited. In order to improve the ability of eddy current probes to inspect deep cracks in metal thick-walled structures, a new eddy current probe using an excitation system with phase shifted fields was proposed. Its feasibility for detecting deep cracks was verified by simulation and experiments. The results showed that the penetration depth of eddy currents in austenitic stainless steel is effectively enhanced by using the new probe.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 275-287
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Practical measurement strategies for verification of freeform surfaces using coordinate measuring machines
Autorzy:
Rajamohan, G.
Shunmugam, M. S.
Samuel, G. L.
Powiązania:
https://bibliotekanauki.pl/articles/220456.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
freeform surface
coordinate measuring machine
machining errors
probe size
sampling strategies
substitute geometry
Opis:
Freeform surfaces have wider engineering applications. Designers use B-splines, Non-Uniform Rational Bsplines, etc. to represent the freeform surfaces in CAD, while the manufacturers employ machines with controllers based on approximating functions or splines. Different errors also creep in during machining operations. Therefore the manufactured freeform surfaces have to be verified for conformance to design specification. Different points on the surface are probed using a coordinate measuring machine and substitute geometry of surface established from the measured points is compared with the design surface. The sampling points are distributed according to different strategies. In the present work, two new strategies of distributing the points on the basis of uniform surface area and dominant points are proposed, considering the geometrical nature of the surfaces. Metrological aspects such as probe contact and margins to be provided along the sides have also been included. The results are discussed in terms of deviation between measured points and substitute surface as well as between design and substitute surfaces, and compared with those obtained with the methods reported in the literature.
Źródło:
Metrology and Measurement Systems; 2011, 18, 2; 209-222
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja sond psychrometrycznych
Psychometric probes calibration
Autorzy:
Guz, Ł.
Suchorab, Z.
Sobczuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/960164.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
sonda psychrometryczna
potencjał wody
wilgotność względna
kalibracja
psychrometric probe
water potential
relative humidity
calibration
Opis:
Potencjał wody jest wyznacznikiem zdolności przemieszczania się wody w materiałach porowatych, jakimi są materiały budowlane. Gdy potencjał wody jest bliski zeru, para wodna zawarta w przegrodzie jest praktycznie w stanie nasycenia i istnieje ryzyko wykroplenia się wody wewnątrz konstrukcji. Zmierzony przez sondę psychrometryczną potencjał wody może być w prosty sposób przeliczony na wilgotność względną materiału porowatego. Aby możliwy był pomiar potencjału wody, należy każdą sondę skalibrować, tzn. określić zależność pomiędzy potencjałem wody i napięciem generowanym na termozłączu. W wyniku zapisu zmieniającego się napięcia na sondzie otrzymuje się krzywą psychrometryczną, której kształt odzwierciedla fizyczne zjawiska przemian fazowych wody zachodzących podczas pomiarów. Przy wilgotności względnej poniżej ok. 92% kształt krzywej psychrometrycznej jednak nie pozwala na jednoznaczne określenie etapu parowania wykroplonej na termozłączu wody, gdyż niewielka ilość wykroplonej wody, odparowując, nie powoduje ustabilizowania się temperatury termozłącza w punkcie rosy. Zmierzone wówczas napięcie generowane wskutek zjawiska Seebecka nie będzie dokładnie odzwierciedlać wilgotności względnej materiału porowatego, dlatego metody wykorzystujące do analizy napięcie na sondzie są wtedy obarczone pewnym błędem. Metoda analizy, wykorzystująca powierzchnię pola pod krzywą psychrometryczną, która jest proporcjonalna do czasu chłodzenia termozłącza, umożliwia w tych warunkach pomiar. Dzięki krzywej kalibracyjnej wiążącej powierzchnię pod krzywą psychrometryczną z potencjałem wody (lub też z wilgotnością względną) można określić stan wilgotności, pomimo iż kształt krzywej psychrometrycznej na to nie pozwala. Powyższa metoda może również obniżyć dolną granicę pomiarową wilgotności względnej dla sond psychrometrycznych.
Water potential determines the ability of water migration in porous materials like buildings materials. When water potential is close to zero, water vapor contained in buildings materials is almost saturated and the risk of water vapor condensation in the wall construction appears. Water potential measured with psychrometric probe can be easily recalculated into moisture of the porous material. To enable the water potential measurements, each probe must be previously calibrated which means finding a correlation between water potential and voltage generated on thermocouple. As a result of voltage changes, the trace on thermocouple junction is forming calibration curve which shape reflects the physical phenomena of water phase transition during measurement. However at the low value of water potential, below 92%, the shape of psychrometric curve does not allow to determine the evaporation phase of condensed water on thermocouple. Evaporation of a small amount of water does not cause the temperature stabilization of the thermocouple at dew point temperature. Measured voltage generated through Seebeck effect would not precisely represent the relative moisture of the porous material, that is why the methods using this voltage on probe will be embarked with some error. In these circumstances very helpful can be the analysis method used field under psychrometric probe, that in some range is proportional to thermocouple cooling time. With calibration curve correlating field under psychrometric curve to water potential (or with relative humidity) it can be determined the water potential even when shape of psychrometric curve not allow to this. This method allows to decrease the lower boundary of measurements with psychrometric probe.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 133-138
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Study on the Electrical and Mechanical Characteristics of Ni-30wt%Co and Cu-2wt%Be Alloy for Development of Semiconductor Test Probe Pin
Autorzy:
Park, Jin-Young
Kim, Young-Choon
Kim, Jae-Gyun
Powiązania:
https://bibliotekanauki.pl/articles/353264.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
probe pin
Be-Cu Alloy
Ni-Co Alloy
test socket
mechanical properties
electrical properties
Opis:
Ultra-precision testing is a very important procedure to secure the reliability of the products as well as for the technology development in the areas of semiconductor and display. Accordingly, companies manufacturing equipment for testing of semiconductor and display have been continuously executing researches for the improvement of the performances of test sockets used in test equipment. Through this study, characteristics of the materials in accordance with the mechanical and electrical properties of Ni-30wt%Co alloy and newly developed Cu-2wt%Be alloy were analyzed in order to select the probe pin material of the socket, which is a key component used in the semiconductor testing equipment. In addition, finite element interpretation was executed by using Ansys Workbench 14.0 to comparatively analyze the finite element interpretation results and experimental results. Experiment was executed for the mechanical properties including tensile strength, elasticity modulus, specific heat, thermal expansion coefficient and Contact Force, for electrical properties, experiment on surface resistance, specific resistance and electrical conductivity was executed to measure the properties. It was confirmed that the results of finite element interpretation and experiment displayed similar trend and it is deemed that the Contact Force value was superior for Be-Co alloy. Through this study, it was confirmed that the newly developed Be-Co alloy is more appropriate as probe pin material used as the core component of test socket used in the semiconductor testing equipment than the existing Ni-Co alloy.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 3; 943-947
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas temperature meter
Autorzy:
Zashchepkina, N. M.
Svyta, M. P.
Powiązania:
https://bibliotekanauki.pl/articles/2105505.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
meter
temperature
PT100
thermal converter
sensor
probe
miernik
temperatura
przetwornik termiczny
czujnik
sonda
Opis:
Purpose: of the article is to develop a digital portable gas temperature meter in the range of -50…+600°C. To measure the temperature of dusty gas flows in the air pollution sources with the least significant digit of the digital device 1°C. Design/methodology/approach: The microprocessor measuring unit, probe and software is proposed. It leads to build a high-precision temperature meter based on a thin film sensor HM220 type "pt100". Findings: The calculation of the electrical schematic diagram parameters for signal conditioning of the sensor relative to the input range of the analog-to-digital converter. The experimental measuring unit and the probe of the gas temperature meter are assembled. The principle of the gas temperature meter calibration with the help of a precision resistance box MSR-60M is considered. The experimental gas temperature meter has a total standard uncertainty determined by type B for a maximum value of the measurement range of 1.94°C. The error of the sensor "pt100" makes the largest contribution to the total standard uncertainty, so the error increases in proportion to the value of the measured temperature. Research limitations/implications: On the basis of the proposed design of gas temperature meter it is possible to construct devices with various lengths of probes. Practical implications: The proposed meter is designed for environmental laboratories that measure the velocity, flow and sampling of dust and gas emissions from sources of air pollution. Originality/value: The device design differs due to the use of thermostable wire made of constantan as extending conductors of the temperature sensor, which is included in the unbalanced Wheatstone bridge. This solution allows the use of unipolar power supply 3.3 V for both analog and digital part of the meter. Temperature meter based on a thin film resistance thermometer is characterized by relative ease of manufacture, low material consumption, cost and high reliability.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 111, 1; 33--41
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The identification method of the sources of radiated electromagnetic disturbances on the basis of measurements in the near-field zone
Autorzy:
Trzcinka, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2141812.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
electromagnetic compatibility
EMC
near electromagnetic field
radiated emission
near-field probe
source of disturbance
Opis:
The paper presents results of tests of a simple device, consisting in the location of a source of disturbance emission by means of measurements within the near field with manual positioning of the measuring probe. The effectiveness of the source of disturbance location was finally verified by a positive result of the radiated emission tests in the EMC laboratory using a standardised method.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2021, 15, 4; 53-64
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Sonication Parameters on the Thickness of the Produced MoS2 Nano-Flakes
Autorzy:
Taghavi, Najme Sadat
Afzalzadeh, Reza
Powiązania:
https://bibliotekanauki.pl/articles/1953512.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
ultrasonic probe
2D MoS2 band gap
power output
pulse percentage
sonication time
Opis:
Liquid Phase Exfoliation (LPE) is a common route to produce two-dimensional MoS2 nanosheets. In this research, MoS2 powder is exfoliated by an ultrasonic probe (sonicator) in a water-ethanol solution. It is reported that MoS2 as a prototype 2D Transition Metal Dichalcogenide, has a band gap that increases with a decreasing number of layers. There are some factors that affect the average band gap energy value and the thickness of the exfoliated flakes. We varied different parameters of the ultrasonic probe like power, pulse percentage and time duration of sonication to investigate the effects on the number of MoS2 layers. Our findings from the UV-Visible spectra, SEM, FESEM and TEM images indicate that the minimum thickness for these samples was acquired at 50% of the input power of the sonicator we used (∼65 W) and the optimum pulse percentage is 50%. The current study also found that the average amount of band gap increased with an increase in sonication time, and then remained unchanged after 60 minutes.
Źródło:
Archives of Acoustics; 2021, 46, 1; 31-40
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędy w autokalibracyjnych pomiarach prądu uziemienia przy użyciu cęgów prądowych
The errors of the autocalibration measurement of the grounding current with clamp-on probe
Autorzy:
Wołoszyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/151856.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
autokalibracyjne pomiary prądu uziemienia
cęgi prądowe
autocalibration measurements of the grounding
clamp-on probe
Opis:
We współczesnych miernikach rezystancji uziemienia normą staje się możliwość kontroli wybranego uziemienia pracujacego w systemie uziemień bez odłączania go od tego systemu. Prad płynący przez uziemienie mierzy się w takim przypadku przy użyciu przetwornika cę gowego. Wymagane znaczne rozmiary "okna" cęgów wymuszają stosowanie przetworników o zakresach pomiarowych wielokrotnie większych od wartości mierzonych prądów, co może prowadzić do powstawania nadmiernych błędów pomiarowych. Znaczną poprawę dokładności można uzyskać poprzez zastosowanie pomiarów etapowych, a nastepnie wartość prądu mierzonego wyznacza się na drodze obliczeniowej.
Measurement of earthing impedance (resistance) of complex earthing from the system without disconnecting the tested earthing from the system is getting more and more popular. In that case current transformer. Required large dimensions of the clamp "window" make it necessary to use a transformer of high current range, very exceeding the actual current value. Such situation may result in unaceptable high measurement errors. The accuracy can be improved with autocalibrating technique.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 9, 9; 17-20
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two dimensional model of CMM probing system
Autorzy:
Ali, Salah H.R.
Powiązania:
https://bibliotekanauki.pl/articles/950738.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
CMM
trigger probe
stylus tip
tip root errors
and two-dimensional-model (2DM)
Opis:
A coordinate measuring machine (CMM) as an automation technology is playing the key role in the modern industry to improve the measurement accuracy. Accurate probing that is computer controlled is the current trend for the next generation of coordinate metrology. However, the CMM probing system is limited by its dynamic root errors that may markedly affect its response characteristics. In this paper, dynamic response errors of CMM measurements have been analyzed. The adopted probe stylus sizes throughout the course of measurements are found to cause some waviness errors during CMM operations due to each of the prescribed angle of the probe tip contact point with the specimen surface and the radius of the stylus tip. Variations in the geometry of the stylus have their consequent effects on its inherent intrinsic dynamic characteristics that in turn would cause relevant systematic root errors in the resulted measurements. Unforeseeable geometrical errors of a CMM using a ductile touch-trigger probing system have been characterized theoretically. These results are analyzed in order to investigate the effect of the dynamic root errors in the light of six probe stylus tip of the situation into account when assessing the accuracy of the CMM measurements. Analytical approaches have been applied on a developed two dimensional model (2DM) of stylus tip to demonstrate the capability of such approaches of emphasizing the root error concept using the strategy of CMM ductile trigger type of probe.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2010, 4, 2; 3-7
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical study of the effect of probe shape on adhesion force between probe and substrate in atomic force microscope experiment
Autorzy:
Yang, L.
Hu, J.
Kong, L.
Powiązania:
https://bibliotekanauki.pl/articles/949319.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
probe shape
adhesion force
van der Waals force
capillary force
relatively humidity
liquid bridge
Opis:
The quantitative description of adhesion force dependence on the probe shapes are of importance in many scientific and industrial fields. In order to elucidate how the adhesion force varied with the probe shape in atomic force microscope manipulation experiment, we performed a theoretical study of the influences of the probe shape (the sphere and parabolic probe) on the adhesion force at different humidity. We found that the combined action of the triple point and the Kelvin radius guiding the trend of the adhesion force, and these two fundamental parameters are closely related to the probe shape. Whilst, the theoretical results demonstrate that the adhesion force is in good agreement with the experiment data if the van der Waals force is taken into account.
Źródło:
Journal of Theoretical and Applied Mechanics; 2015, 53, 1; 235-241
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Zno Nano Material Interaction With Nd:YAG Laser Under Vacuum
Autorzy:
Hussam, N. Mohammed Ali
Yahya, Abdulkreem Salman
Powiązania:
https://bibliotekanauki.pl/articles/1179694.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Langmuir probe
Nd:YAG laser etching
Plasma generation
ZnO nanomaterial
electron density
electron temperature
Opis:
The goal of this paper is to study the Nd:YAG laser interaction with the ZnO nanomaterial by etching the ZnO nanodisc surface. The preparation of ZnO nanodisc is studied also and the setup which we use in previous experiment published in the (IJRRR, Vol. X, Issue 1, March 2017) is used also. The interaction is done under vacuum conditions with high pressure in the range of (10-3) Tor. The main target of the paper is to study the plasma generated from the etching of the ZnO nanodisc by Nd:YAG laser.
Źródło:
World Scientific News; 2017, 72; 248-255
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wiarygodności i przydatności sygnałów diagnostycznych do bezinwazyjnej oceny stanu maszyn elektrycznych
Evaluation of the reliability and usefulness of diagnostic signals for noninvasive assessment of electrical machines states
Autorzy:
Sułowicz, M.
Petryna, J.
Weinreb, K.
Duda, A.
Tulicki, J.
Powiązania:
https://bibliotekanauki.pl/articles/1367400.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
cęgi prądowe
cewka Rogowskiego
wiarygodność pomiaru
clamp current probe
Rogowski coil
credibility of measurement
Opis:
The paper presents analyses of diagnostic signals of currents and axial flux, which were recorded in various possible available measuring points. Some detailed diagnostic analyses based on examples of the measurements made in industry and at the testing station were carried out. For current signals, there was performed an analysis of signals recorded in the secondary circuits of current transformers using Hall effect sensors and an analysis of currents recorded in the primary circuits of high voltage machines with use of Rogowski coils as well. For an axial flux it appeared which important diagnostic symptoms are possible to record using this method of measurement. Some detailed conclusions of the authors about the reliability of applied technique of measurements of currents in the primary main circuits and secondary circuits of current transformers and the usefulness of axial flux measurement method for quick initial evaluation of the machine condition are also included. In the summary submitted are recommendations and guidelines on the use of specific methods of measurement depending on the measuring capability, accuracy and particularity of the diagnosis we want to get about the condition of the machine.
W artykule przedstawiono analizy sygnałów diagnostycznych prądów i strumienia poosiowego, które rejestrowano w różnych możliwych dostępnych punktach pomiarowych. Na przykładach wykonanych pomiarów na stacji prób i w laboratorium badawczym przeprowadzono szczegółowe analizy diagnostyczne. Dla sygnałów prądowych przeprowadzono analizę sygnałów rejestrowanych w obwodach wtórnych przekładników prądowych przy pomocy przetworników hallotronowych oraz prądów rejestrowanych w obwodach pierwotnych maszyn wysokonapięciowych przy użyciu cewek Rogowskiego. Dla strumienia poosiowego pokazano, jakie istotne symptomy diagnostyczne są możliwe do zarejestrowania przy pomocy tej metody pomiarowej. Przedstawiono szczegółowe wnioski autorów co do wiarygodności stosowanych pomiarów prądów w obwodach pierwotnych i obwodach wtórnych przekładników oraz przydatności metody pomiaru strumienia poosiowego do szybkiej wstępnej oceny stanu maszyny. W podsumowaniu przedstawiono zalecenia i wytyczne co do użycia konkretnych metod pomiarowych w zależności od możliwości pomiarowych i dokładności oraz szczegółowości diagnozy, którą chcemy uzyskać co do stanu maszyny.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 3, 111; 139-146
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interspecies hybridizations in situ with bovine heterosome painting probes for identification of sex chromosomes in fallow deer (Dama dama)
Międzygatunkowe hybrydyzacje in situ z bydlęcymi sondami malującymi heterosomy do identyfikacji chromosomów płci u daniela (Dama dama)
Autorzy:
Kozubska-Sobocińska, A.
Danielak-Czech, B.
Babicz, M.
Bąk, A.
Rejduch, B.
Powiązania:
https://bibliotekanauki.pl/articles/2196998.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
interspecies hybridization
in situ
heterosome
painting probe
identification
sex chromosome
fallow deer
Dama dama
Źródło:
Annales Universitatis Mariae Curie-Skłodowska. Sectio EE: Zootechnica; 2013, 31, 4; 95-97
0239-4243
2083-7399
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska. Sectio EE: Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surrogate synthesis of frame eddy current probes with uniform sensitivity in the testing zone
Autorzy:
Halchenko, Volodymyr Ya.
Trembovetska, Ruslana
Tychkov, Volodymyr
Powiązania:
https://bibliotekanauki.pl/articles/1848998.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy current probe
uniform sensitivity
metamodel
additive neural network regression
surrogate optimization
global extremum
Opis:
A mathematical method for nonlinear surrogate synthesis of frame surface eddy current probes providing a uniform eddy current density distribution in the testing object area is proposed. A metamodel of a frame movable eddy-current probe with a planar excitation system structure, used in the algorithm for surrogate optimal synthesis was created. The examples of a nonlinear synthesis of excitation systems with the application of the modern metaheuristic stochastic algorithms for finding the global extremum are considered. The numerical findings of the problem analyses are presented. The efficiency of the synthesized excitation structures was demonstrated on the basis of the eddy current density distribution graphs on the surface of the control zone of the object in comparison with classical analogues.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 551-564
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surrogate synthesis of frame eddy current probes with uniform sensitivity in the testing zone
Autorzy:
Halchenko, Volodymyr Ya.
Trembovetska, Ruslana
Tychkov, Volodymyr
Powiązania:
https://bibliotekanauki.pl/articles/1849043.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy current probe
uniform sensitivity
metamodel
additive neural network regression
surrogate optimization
global extremum
Opis:
A mathematical method for nonlinear surrogate synthesis of frame surface eddy current probes providing a uniform eddy current density distribution in the testing object area is proposed. A metamodel of a frame movable eddy-current probe with a planar excitation system structure, used in the algorithm for surrogate optimal synthesis was created. The examples of a nonlinear synthesis of excitation systems with the application of the modern metaheuristic stochastic algorithms for finding the global extremum are considered. The numerical findings of the problem analyses are presented. The efficiency of the synthesized excitation structures was demonstrated on the basis of the eddy current density distribution graphs on the surface of the control zone of the object in comparison with classical analogues.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 551-564
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surrogate synthesis of frame eddy current probes with uniform sensitivity in the testing zone
Autorzy:
Halchenko, Volodymyr Ya.
Trembovetska, Ruslana
Tychkov, Volodymyr
Powiązania:
https://bibliotekanauki.pl/articles/1849059.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
eddy current probe
uniform sensitivity
metamodel
additive neural network regression
surrogate optimization
global extremum
Opis:
A mathematical method for nonlinear surrogate synthesis of frame surface eddy current probes providing a uniform eddy current density distribution in the testing object area is proposed. A metamodel of a frame movable eddy-current probe with a planar excitation system structure, used in the algorithm for surrogate optimal synthesis was created. The examples of a nonlinear synthesis of excitation systems with the application of the modern metaheuristic stochastic algorithms for finding the global extremum are considered. The numerical findings of the problem analyses are presented. The efficiency of the synthesized excitation structures was demonstrated on the basis of the eddy current density distribution graphs on the surface of the control zone of the object in comparison with classical analogues.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 551-564
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie techniki pomiarowej TDR w badaniach terenowych przy wykorzystaniu sond powierzchniowych
Application of the TDR measuring technique for in-situ measurements using surface probes
Autorzy:
Suchorab, Z.
Pavlik, Z.
Černý, R.
Powiązania:
https://bibliotekanauki.pl/articles/390200.pdf
Data publikacji:
2011
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
pomiary wilgotności
sonda powierzchniowa TDR
technika reflektometryczna
moisture measurements
surface TDR probe
reflectometric technique
Opis:
W artykule przedstawiono możliwość wykonywania pomiarów terenowych wilgotności murów za pomocą techniki TDR (ang. Time Domain Reflectometry). W celu wyeliminowania dotychczasowych wad niniejszej techniki, do których należy zaliczyć przede wszystkim jej inwazyjny charakter i konieczność wykonywania nawierceń w murach, opracowano i wykonano kilka prototypów sondy powierzchniowej. Dzięki zastosowaniu takiego rozwiązania czujnika, możliwe było przeprowadzenie badań na zasadzie dotykowej z pełnym wykorzystaniem potencjału techniki pomiarowej TDR – szybkości odczytu oraz braku wraż- liwości na zasolenie badanego ośrodka. Pomiary wykonano w murach z cegły ceramicznej pełnej budynku zlokalizowanego przy ul. Pierwszego Maja 20 w Lublinie.
The article presents the possibility of in-situ measurements of building barriers moisture using the TDR technique (Time Domain Reflectometry). To minimize the previous disadvantages of the described method – invasive character, several prototypes of the surface probes were manufactured. With such a sensor solution it was possible to conduct the non-invasive measurements using the full TDR method potential – quick measurements and no sensitivity of salinity influence. The measurements were conducted on the brickworks made of red ceramic brick at the old building located on 1st of May Street in Lublin.
Źródło:
Budownictwo i Architektura; 2011, 8, 1; 97-106
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement Accuracy Investigation of Touch Trigger Probe with Five-Axis Machine Tools
Badania dokładności pomiarów elektrostykową sondą przełączającą na obrabiarkach pięcioosiowych
Autorzy:
Rahman, M. M.
Mayer, J. R. R.
Powiązania:
https://bibliotekanauki.pl/articles/139534.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
probing
machine tool
touch probe
repeatability
measurement inaccuracy
sondowanie
obrabiarka
sonda stykowa
powtarzalność
niedokładność pomiaru
Opis:
The touch trigger probe plays an important role in modern metrology because of its robust and compact design with crash protection, long life and excellent repeatability. Aside from coordinate measuring machines (CMM), touch trigger probes are used for workpiece location on a machine tool and for the accuracy assessment of the machine tools. As a result, the accuracy of the measurement is a matter of interest to the users. The touch trigger probe itself as well as the measuring surface, the machine tool, measuring environment etc. contribute to measurement inaccuracies. The paper presents the effect of surface irregularities, surface wetness due to cutting fluid and probing direction on probing accuracy on a machine tool.
Elektrostykowe sondy przełączające grają istotną rolę we współczesnej metrologii z uwagi na ich zwartą i silną konstrukcję, odporność na uszkodzenia, długowieczność i doskonałą powtarzalność. Obok zastosowań we współrzędnościowych maszynach pomiarowych (CMM), sondy te są wykorzystywane do wyznaczenia położenia przedmiotu obrabianego na obrabiarce i oceny dokładności obrabiarek. Tak więc, dokładność pomiaru jest sprawą istotną dla użytkowników. Do powstawania niedokładności pomiaru przyczynia się sama sonda, a także powierzchnia pomiarowa, obrabiarka, środowisko pomiarowe itp. W artykule przedstawiono wpływ nierówności powierzchni, wilgotności powierzchni powodowanej obecnością chłodziwa i kierunku sondowania na dokładność pomiaru na obrabiarce.
Źródło:
Archive of Mechanical Engineering; 2016, LXIII, 4; 495-510
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Poprawność lokalizacji strefy najmniejszego dogrzania a jakość i bezpieczeństwo żywności utrwalanej termicznie
Correctness location the least-heat zone and quality and safety of thermally preserved food
Autorzy:
Czyżewski, Ł.
Szczepka, M.
Mizgalski, I.
Stasiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1366445.pdf
Data publikacji:
2018
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
sterylizacja
strefa najmniejszego dogrzania
wieloczujnikowa sonda temperatury
sterilization
least-heat zone
multi-sensor temperature probe
Opis:
W pracy opisano pomiar procesów sterylizacji dwóch produktów – sosu bolońskiego w opakowaniu szklanym oraz fasoli czerwonej w stalowej puszce, przy wykorzystaniu opracowanej w COBRABiD sp. z o.o. wieloczujnikowej sondy temperatury. Badania dotyczyły różnic zmierzonych wartości sterylizacyjnych w zależności od odległości między elementem pomiarowym sondy temperatury a strefą najmniejszego dogrzania w przetworze. Uzyskane podczas pomiarów rezultaty pozwoliły na eksperymentalne wyznaczenie strefy najmniejszego dogrzania, która znajdowała się w najbliższym otoczeniu elementu pomiarowego umieszczonego najgłębiej w produkcie. Wieloczujnikowa sonda temperatury umożliwiła dokładną analizę rozkładu temperatury w obrębie wsadu poddanego procesowi sterylizacji, co w zdecydowany sposób ograniczyło liczbę koniecznych do wykonania pomiarów przy wykorzystaniu tradycyjnych sond jednoczujnikowych.
This paper describes the sterilization processes of two products – the Bolognese sauce in a glass packaging and red beans in a steel can with the use of the multi-sensor temperature probe developed in COBRABiD Ltd. The research concerned the differences of the measured sterilization values depending on the distance of the temperature probe measuring element from the least-heat zone in the product. The results obtained during the measurements allowed for the experimental determination of the zone of the smallest heating, which was located in the immediate vicinity of the measuring element placed deepest in the product. The multi-sensor temperature probe made it possible to accurately analyze the temperature distribution within the charge subjected to the sterilization process, which significantly reduced the number of measurements necessary to perform using the traditional single sensor probes.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2018, 23, 3; 111-116
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sondowanie statyczne CPT
Autorzy:
Traczyński, K.
Grela, M.
Powiązania:
https://bibliotekanauki.pl/articles/365605.pdf
Data publikacji:
2011
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
geotechnika
Sondowania statyczne
sondowanie
cone penetration test
geotechnics
probe CPT
probing
Sonda CPT
static soundings
Opis:
Sonda CPT daje wyniki zbliżone do rzeczywistych, co pozwala optymalizować wielkość nakładów finansowych na fundamentowanie. Koszty sondowania i wykonania odwiertów są porównywalne, dlatego też tylko od świadomości inwestora i dostępności sprzętu zależy, czy takie badania zostaną wykonane.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2011, 4; 70-71
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of hydrogenated carbon deposits formed in fusion reactors with carbon walls by reactive oxygen particles
Autorzy:
Mozetič, M.
Powiązania:
https://bibliotekanauki.pl/articles/146410.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
hydrogenated carbon deposits
neutral oxygen atoms
heterogeneous surface recombination
fiber optics catalytic probe
fuel removal
Opis:
A method for removal of hydrogenated carbon deposits from the walls of fusion reactors with carbon divertors is presented. The method is based on interaction of neutral oxygen atoms with deposits at elevated temperatures typically found in such fusion reactors. The source of neutral oxygen atoms is oxygen plasma created with electrodeless high frequency discharges. The density of oxygen atoms in such plasma may approach 1022 m-3 making such discharges suitable for removal of deposits in huge systems like tokamaks.
Źródło:
Nukleonika; 2012, 57, 2; 269-275
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electromagnetic pulses produced by expanding laser - produced Au plasma
Autorzy:
De Marco, M.
Cikhardt, J.
Krása, J.
Velyhan, A.
Pfeifer, M.
Krouský, E.
Klír, D.
Řezáč, D.
Limpouch, J.
Margarone, D.
Ullschmied, J.
Powiązania:
https://bibliotekanauki.pl/articles/147922.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
laser-produced plasma
electromagnetic pulse (EMP)
return target current
Moebius loop antenna
inductive target probe
Opis:
The interaction of an intense laser pulse with a solid target produces large number of fast free electrons. This emission gives rise to two distinct sources of the electromagnetic pulse (EMP): the pulsed return current through the holder of the target and the out flow of electrons into the vacuum. A relation between the characteristics of laser-produced plasma, the target return current and the EMP emission are presented in the case of a massive Au target irradiated with the intensity of up to 3 × 1016 W/cm2. The emission of the EMP was recorded using a 12 cm diameter Moebius loop antennas, and the target return current was measured using a new type of inductive target probe (T-probe). The simultaneous use of the inductive target probe and the Moebius loop antenna represents a new useful way of diagnosing the laser–matter interaction, which was employed to distinguish between laser-generated ion sources driven by low and high contrast laser pulses.
Źródło:
Nukleonika; 2015, 60, 2; 239-243
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Progress in the development of the semi-empirical calibration of neutron probes based on Monte Carlo modeling
Autorzy:
Woźnicka, Urszula
Powiązania:
https://bibliotekanauki.pl/articles/1841776.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
neutron well logging
calibration of the borehole neutron probe
general neutron parameter of neutron transport
Opis:
The method of the semi-empirical calibration of a neutron well logging probe was developed by Jan Andrzej Czubek on the concept of the general neutron parameter (GNP) and tested positively at the neutron calibration station in Zielona Góra, Poland. The neutron probe responses in a wide range of neutron parameters (and thus lithology, porosity and saturation) were also computed using the Monte Carlo method. The obtained simulation results made it possible to determine the calibration curves using the Czubek concept in a wider range than by means of the original method. The very good compatibility of both methods confirms the applicability of the GNP as well as the Monte Carlo numerical experiments, which allow for a significant extension of the semi-empirical calibration in complex well geometries taking into account e.g., casing or invaded zones.
Źródło:
Geology, Geophysics and Environment; 2020, 46, 3; 251-254
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych czynników aparaturowo-technicznych wpływających na wyniki badań USG
Analysis of selected technical-apparatus factors affecting the results of researches ultrasound
Autorzy:
Niemasek, K.
Tutaj, J.
Powiązania:
https://bibliotekanauki.pl/articles/98838.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
USG Dopplera
głowica ultrasonograficzna
parametry przepływu krwi
Doppler ultrasound
ultrasound probe
parameters of blood flow
Opis:
W artykule przedstawiono analizę wpływu ugięcia wiązki Dopplera widmowego w zakresie ±10°, w stosunku do wiązki wykorzystywanej do uzyskania obrazu B, na wyniki otrzymanych parametrów przepływu krwi w badaniach ultrasonograficznych tętnic szyjnych wspólnych za pomocą metody Duplex Doppler w połączeniu z kolorowym obrazowaniem przepływu krwi. Analiza ta pozwala na obserwację zmian otrzymanych parametrów w grupie kobiet i mężczyzn wynikających z nachylenia wiązki dopplerowskiej.
The article presents an analysis of the impact of the beam deflection of the Doppler spectrum in the range of ±10 °, relative to the beam used to obtain an image B, the results of the parameters obtained in studies of blood flow in carotid artery ultrasonography using duplex Doppler methods in conjunction with color flow imaging blood. This analysis allows to observe the changes in the parameters obtained in the group of men and women under the Doppler beam tilt.
Źródło:
Aktualne Problemy Biomechaniki; 2013, 7; 125-130
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory measurements of moisture in a model red-brick wall using the surface TDR probe
Laboratoryjne pomiary wilgotności w modelowej ściance z cegły ceramicznej pełnej za pomocą powierzchniowej sondy TDR
Autorzy:
Suchorab, Z.
Powiązania:
https://bibliotekanauki.pl/articles/125715.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
capillary rise
red brick
surface TDR probe
podciąganie kapilarne
cegła ceramiczna pełna
powierzchniowe sondy TDR
Opis:
The article presents the non-invasive attempt to moisture determination using the electric methods. The first part of the article describes the problem of moisture in the building barriers and the possibilities of its determination. The special attention is put on the electric methods of moisture determination. Second part of paper is experimental. For the experiment a model red-brick wall was built and prepared for water uptake process. The experiment was monitored by the capacitance and surface TDR probes which enabled to avoid the necessity of sampling or material destruction. Conducted experiments show the progress of water uptake phenomenon in the model wall and prove the potential of the non-invasive measurements using the surface TDR probes.
Artykuł przedstawia bezinwazyjny sposób pomiaru wilgotności z wykorzystaniem metod elektrycznych. W pierwszej części artykułu omówiono problem nadmiernego zawilgocenia przegród budowlanych i sposoby pomiaru tego zjawiska. Druga część pracy ma charakter eksperymentalny. Przygotowano modelową ściankę z cegły ceramicznej pełnej w celu zbadania zjawiska podciągania kapilarnego. Omawiany proces był monitorowany za pomocą czujników pojemnościowych oraz powierzchniowych sond TDR, co umożliwiło bezinwazyjne pomiary, niewymagające pobrania fragmentów muru lub innych ingerencji w badany materiał. Uzyskane wyniki pozwalają na śledzenie procesu podciągania kapilarnego w modelowej ściance z cegły ceramicznej pełnej i potwierdzają możliwości sondy powierzchniowej TDR w pomiarach wilgotnościowych murów.
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 171-176
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sposoby wyznaczania głębokości położenia przewodów podziemnych różnymi lokalizatorami elektronicznymi
Methods for underground utility depth determination using various locators
Autorzy:
Sołtys, M.
Powiązania:
https://bibliotekanauki.pl/articles/262267.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
lokalizator elektromagnetyczny
przewód podziemny
sonda nadawcza
znacznik elektromagnetyczny
electromagnetic locator
underground utility
transmitting probe
electromagnetic marker
Opis:
W pracy przedstawiono metody wyznaczania głębokości położenia podziemnych przewodów metalowych i niemetalowych z uwzględnieniem możliwości wielofunkcyjnych lokalizatorów oraz dodatkowego wyposażenia obejmującego znaczniki elektromagnetyczne, taśmy lokalizacyjne i sondy nadawcze. Podano wyniki prac doświadczalnych oraz ocenę dokładności automatycznego pomiaru głębokości nowoczesnym lokalizatorem. Przedstawiono zakres i dokładności określania głębokości niektórymi lokalizatorami w odniesieniu do przewodów, znaczników elektromagnetycznych i sond nadawczych.
The paper presents methods for determination of depth of underground metallic and nonmetallic utilities, using multifunctional electronic locators and additional accessories, like electromagnetic markers, location tapes and transmitting probes. Results of practical experiments are discussed. An accuracy assessment of automatic depth surveys using modern locators are given. The range and accuracy of utility depth determination with chosen locators, markers and probes are presented.
Źródło:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2005, 11, 2; 345-356
1234-6608
Pojawia się w:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja źródeł hałasu na przykładzie agregatu hydraulicznego
Noise source localization – hydraulic unit
Autorzy:
Fiebig, W.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/269560.pdf
Data publikacji:
2014
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
lokalizacja źródeł hałasu
hydraulika
kamera akustyczna
sonda natężeniowa
noise localization
hydraulic unit
intensity probe
acoustic camera
Opis:
W artykule omówiono główne problemy związane z hałasem występującym w urządzeniach hydraulicznych oraz przyczyny jego występowania. Przeprowadzona została lokalizacja źródeł hałasu na przykładzie agregatu hydraulicznego. Zastosowana została metodą pomiaru natężenia dźwięku sondą dwumikrofonową oraz kamerą akustyczną. Stworzone zostały mapy akustyczne oraz ranking poziomów mocy akustycznej dla każdej z powierzchni. Porównano wnioski uzyskane w przypadku każdej z metod dotyczące lokalizacji głównego źródła hałasu dla dwóch zakresów częstotliwości.
This paper presents the main problems associated with noise emission and causes of noise in hydraulic devices. Noise source localization procedures were conducted on a hydraulic unit commonly used in industry. The noise localization measurements were conducted with use of two methods: Sound Intensity Probe measurement and an Acoustic Camera beamforming algorithm. A set of acoustic maps and acoustic photos was created. A total acoustic power level ranking was created. Results obtained in each method were compered. Main noise sources were detected and assigned to frequency rages.
Źródło:
Inżynieria Maszyn; 2014, R. 19, z. 2; 92-98
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości zastosowania echosondy „CHEMKOP” i kawernomierza wielkośrednicowego do badania kawern podziemnych
Application possibilities of the CHEMKOP ultrasonic probe and large-scale borehole cavernometer in investigation of underground caverns
Autorzy:
Nguyen, Dinh Chau
Kubacka, Tomasz
Figarski, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/164396.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
kawernomierz wielkośrednicowy
echosonda
kawerny
węglowodory
solanka
large-scale cavernometer
ultrasonic probe
caverns
hydrocarbon liquid
gas
brine
Opis:
W tej pracy przedstawiono możliwości zastosowania geofizycznych sond otworowych, tj. kawernomierza wielkośrednicowego i echosondy ultradźwiękowej, które zostały skonstruowane przez Ośrodek Badawczo-Rozwojowy Górnictwa Surowców Chemicznych „CHEMKOP” Sp. z o.o. do badania kształtu i rozmiarów kawern powstałych w wysadach oraz pokładach solnych. Zbadano zarówno w warunkach laboratoryjnych, jak i rzeczywistych wpływ temperatury, ciśnienia i zasolenia cieczy na prędkość rozchodzenia fali ultradźwiękowej. Podano również sposoby określenia granicy między szyją a stropem kawern, granicy rozdziału faz między gazem a solanką zawartych w kawernach. Badania te realizowane są na etapie eksploatacji pokładu soli złożowej oraz podczas magazynowania w kawernach węglowodorów ciekłych lub gazowych.
This paper presents the application possibilities of the large-scale cavernometer and echo probe produced by CHEMKOP Company in the study of the shape and geometrical parameters of the underground caverns formed in consequence of salt deposits exploitation. The influence of temperature, pressure and mineralization of the brine on the propagation velocity of the acoustic wave was tested in both laboratory and real conditions. The methods for localization of the boundary between borehole and cavern body as well as the boundary between gas and brine were proposed. The measurements of the geometrical parameter using the mentioned probes could be made during salt exploitation as well as during accumulation of the hydrocarbon liquid fuel in the studied caverns.
Źródło:
Przegląd Górniczy; 2019, 75, 4; 1-7
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of the Phase Mismatch Error in PP Probe Using Synchronous Measurement Technique
Wykorzystanie synchronicznego pomiaru do eliminacji błędu fazowego w sondzie typu PP
Autorzy:
Raczyński, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2090886.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
PP-probe
sound intensity
phase mismatch error
sonda natężeniowa typu PP
błąd niedopasowania fazy
pomiar natężenia dźwięku
Opis:
The paper presents a modification of the pressure-pressure (PP) sound intensity measurement method. In the proposed solution simultaneous measurement with a pair of microphones (used in the classical PP probe) is replaced by a sequence of measurements taken with a single microphone placed in successive positions. This approach requires an additional (reference) microphone to synchronize the successive measurements. Although, in the process of calculating the sound intensity only the signal from the measurement microphone is used. Thanks of this the errors associated with differences in the frequency responses of the measurement microphones (especially phase mismatch error) that occurs in the classical PP method are eliminated. This approach simultaneously increases the random error and limits the measurements to periodic signals only. The article presents the principle of operation of the classical PP probe and the currently used methods of phase mismatch error elimination based on pre-calibration of the probe. Next, the theoretical basis of the proposed measurement method is described. To verify the effectiveness of phase mismatch error elimination in the proposed method, an experiment was conducted. It consisted in estimation the angle of incidence of an acoustic wave under controlled conditions in an anechoic chamber. The measurement was carried out with the classical PP probe and with the modified method. Measurements were made for different sound sources (a loudspeaker set and a small electrical device). In the final part of the paper, the results are discussed, both methods (classical and modified) are compared and potential applications of the proposed method are indicated.
W artykule zaprezentowano modyfikację metody pomiaru natężenia dźwięku z wykorzystaniem sondy PP (ang. pressure-pressure). W zaproponowanym rozwiązaniu jednoczesny pomiar ciśnienia akustycznego za pomocą dwóch mikrofonów pomiarowych (używanych w klasycznej sondzie PP) został zastąpiony sekwencją pomiarów dokonywanych jednym mikrofonem pomiarowym umieszczanym w kolejnych pozycjach. Zaproponowana metoda pozwala na eliminację błędu związanego z niejednakowymi odpowiedziami częstotliwościowymi (głównie fazowymi) mikrofonów użytych w klasycznej sondzie PP. Jej zastosowanie jest ograniczone do pomiaru sygnałów okresowych. Jednocześnie wzrasta błąd przypadkowy, który można jednak wyeliminować metodami statystycznymi. Pomimo, że zaproponowane podejście wymaga zastosowania mechanizmu synchronizacji pomiarów i użycia w tym celu dodatkowego mikrofonu pomocniczego, to w samym procesie wyznaczania natężenia dźwięku bierze udział jedynie sygnał z mikrofonu pomiarowego. W artykule zaprezentowano zasady pomiaru natężenia dźwięku za pomocą klasycznej sondy PP oraz obecnie stosowane metody eliminacji błędów związanych z niedopasowaniem charakterystyk częstotliwościowych mikrofonów, bazujące na wstępnej kalibracji sondy. Następnie przedstawione są teoretyczne podstawy zaproponowanej metody pomiarowej. Aby zweryfikować jej skuteczność przeprowadzono eksperyment pomiarowy polegający na pomiarze kąta padania fali akustycznej w ściśle określonych warunkach w komorze bezechowej. Eksperyment przeprowadzono z wykorzystaniem klasycznej metody PP oraz z wykorzystaniem zaproponowanej metody zmodyfikowanej. Dokonano pomiarów dla różnych źródeł dźwięku (zestawu głośnikowego oraz małego urządzenia elektrycznego). W końcowej części artykułu wyniki porównawcze są poddane dyskusji w celu wskazania potencjalnych zastosowań zaproponowanej metody.
Źródło:
Pomiary Automatyka Robotyka; 2022, 26, 2; 35--46
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości i ograniczenia diagnozowania instrumentalnego w badaniach statyki drzew – Część 1
Oportunities and limitations of instrumental diagnosis in trees statics assessment – Part 1
Autorzy:
Suchocka, M.
Kolasiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/400136.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
świder przyrostowy
sonda arborystyczna
młotek elektryczny
shigometr
rezystograf
VTA
incremental drill
arborist probe
electric hammer
shigometer
resistograph
Opis:
Wśród urzędników samorządów lokalnych odpowiedzialnych za zieleń, szerokiego grona społeczeństwa, a nawet wśród osób zawodowo zajmujących się drzewami, krążą często sprzeczne opinie na temat wykorzystania do ich diagnostyki nowoczesnych technologii. Znajomość możliwości ich stosowania ma kluczowe znaczenie w podejmowaniu decyzji dotyczących drzew dojrzałych i sędziwych. Praca powstała w oparciu o wieloletnie doświadczenie autorów w diagnostyce drzew. Została poparta przykładami z praktyki a także zaprezentowano badania i opinie najlepszych specjalistów w tej dziedzinie na świecie. Każde urządzenie ma swoje mocne i słabe strony. Umiejętność jego zastosowania bez właściwej interpretacji uzyskanych wyników może prowadzić do błędnych wniosków a tym samym podejmowanych decyzji. W artykule omówiono stosowanie prostych sprzętów diagnostycznych. Diagnostyka instrumentalna wspomaga prawidłową ocenę drzew lecz wymaga dużej wiedzy i doświadczenia w interpretacji uzyskanych wyników.
Among the officials of local governments responsible for urban forest, a wide range of society, and even among people professionally dealing with trees, there are often conflicting opinions about the use of modern technology for their diagnosis. Knowledge of its applicability is crucial in making decisions about mature and aged trees. The work was based on many years of experience of the authors in the diagnosis of trees. It was supported by examples from practice and also presented research and opinions of the best specialists in this field in the world. Each device has its strengths and weaknesses. The ability to use it without proper interpretation of the obtained results may lead to wrong conclusions and thus the decisions made. The use of simple diagnostic equipment has been discussed. Instrumental diagnosis supports the correct assessment of trees, but requires a sufficient knowledge and experience in interpreting obtained results.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 5; 14-18
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies