Tytuł:
Photodegradation of Lower Polybrominated Diphenyl Ether Congeners in Indoor Air – Model Studies
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124336.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PBDEs
indoor air quality
flame retardants
photolytic degradation
Opis:
Polybrominated diphenyl ethers (PBDEs) are additive flame retardants which have found applications in polymers for many consumer plastic and electronic goods. Wide use of these chemicals has led to their extremely high concentrations in the indor environments. This paper presents an exploratory study of the photodebromination of five individual lower polybrominated diphenyl ether congeners (BDE-28, BDE-47, BDE-99, BDE-100 and BDE-101) irradiated with white light and different UV (A, B, C) light ranges. The capability of photodegradation of lower PBDEs under room lights was proven by the debromination which occurred with various effectiveness for the selected PBDE congeners and depended of light source. Almost all PBDE congeners showed the greatest decay when exposed to UV-C, with the exception of BDE-100. The decay of irradiated congeners occurred rapidly during the first 5 min of experiment. The final degradation varied from 38% decay (BDE-28, UV-C) to 94% (BDE-47, UV-C). These findings can help in predicting PBDE behavior in indoors and also be useful in the design of PBDE remediation processes.
Źródło:
Journal of Ecological Engineering; 2017, 18, 3; 180-186
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwość poprawy jakości powietrza w polskich szkołach w wyniku modernizacji opartej na zasadach zrównoważonego rozwoju
Autorzy:
Sowa, J.
Panek, A.
Powiązania:
https://bibliotekanauki.pl/articles/362510.pdf
Data publikacji:
2005
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
jakość powietrza wewnętrznego
zasada zrównoważonego rozwoju
indoor air quality
Opis:
The paper describes part of the results of the Polish/Norwegian scientific cooperation within the project SUREBUILD, funded by the Norwegian Ministry of Foreign Affairs. The whole project is devoted to sustainable redevelopment of buildings in Poland, but special attention was paid to Polish schools constructed between 1958-1966 (the "Millenium" schools). Potential technologies for sustainable modernization of Polish schools were analyzed taking into consideration energetic, environmental, economic and other related criterions. Substantial part of the work was devoted to fin d the economically feasible technologies that might improve current unsatisfactory level of indoor air quality in Polish schools. The paper presents general recommendations for the moderniza- tion of ventilation system s in Polish schools as well as describes the technologies selected for school in Zgierz, the case study object of the project.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2005, T. 1; 305-314
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perceived indoor air quality, air-related symptoms and ventilation in Finnish hospitals
Autorzy:
Hellgren, Ulla-Maija
Hyvärinen, Markku
Holopainen, Rauno
Reijula, Kari
Powiązania:
https://bibliotekanauki.pl/articles/2185474.pdf
Data publikacji:
2011-03-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
evaluation of ventilation
Indoor Air Questionnaire
perceived indoor air quality
Health care workers
Opis:
Objectives: Good ventilation is more important in hospitals than in many other buildings. The objective of this study was to evaluate the effect of the condition, performance and modernity of ventilation systems on the perceived indoor air quality (IAQ) and the indoor air-related symptoms of hospital personnel. Materials and Methods: An inspection and evaluation graded on a 1 to 3 scale of the condition, performance, and modernity of the ventilation systems was carried out in ten central hospitals in Finland. The perceived IAQ and the related symptoms were collected by means of an indoor air questionnaire survey among the workers in these hospitals. Results: The condition, performance and modernity of the ventilation systems were good in 40% of the hospitals included in the research and poor in another 40% of them. In hospitals where the majority of the ventilation systems were assessed to be good, the prevalence of the indoor air-related complaints and symptoms was lower than in hospitals where the majority of the ventilation systems were assessed as needing extensive repairs. Conclusions: The condition and performance of the ventilation systems in hospitals had a significant impact on the perceived IAQ and the symptoms observed among the employees in Finnish hospitals. Therefore, it is important that hospital ventilation systems are maintained properly and regularly. Furthermore, they should be renovated, at the latest when their technical lifespan expires.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 1; 48-56
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of integrated indoor environmental air quality parameters in selected church buildings of Faisalabad city: a statistical based comparative study
Autorzy:
Hussain, Zahid
Khan, Mohammad S.
Kundi, Kundi
Alaf, Kashif
Ullah, Yasir
Powiązania:
https://bibliotekanauki.pl/articles/35518580.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
indoor air quality
church buildings
particulate matter
public health
air pollution
Opis:
The objective of this study is to control the air quality parameters for a selected range of different particulate matters. A comprehensive experimental approach is established to regulate the quality of air about a selected range of different air pollutants being investigated in the indoor atmosphere of the church building. Relative humidity, temperature, carbon dioxide, particulate matter and radon were considered as the factors of air quality extents. For establishing the association among the selected parameters, the data were mathematically analyzed. The correlation coefficient confirmed a strong relationship between the indoor CO2 level and the number of public. A negative relationship between the indoor CO2 extent and indoor temperature confirmed that due to the increase in temperature the concentration of CO2 decreased as well. A solid adverse connection among indoor relative humidity and indoor air temperature showed that due to the increase in air temperature, the level of the relative humidity decreased. Some recommendations were proposed for the treatment of air quality in church buildings for human well-being.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 134-147
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacterial and Fungal Aerosols in Air-Conditioned Office Buildings in Warsaw, Poland—The Winter Season
Autorzy:
Gołofit-Szymczak, M.
Górny, R. L.
Powiązania:
https://bibliotekanauki.pl/articles/90052.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
indoor air quality
office buildings
bacterial and fungal aerosols
size distribution
Opis:
The microbial quality of the working environment was assessed in winter in air-conditioned office buildings in Warsaw. The average indoor concentrations of bacterial and fungal aerosols were low (<103 cfu∙m–3), below Polish proposals for threshold limit values in public service buildings. Even during cold months, if the air-conditioning system works properly, people remain the main source of bacterial aerosol in offices, whereas infiltration of outdoor air remains a major mechanism responsible for their fungal contamination. An analysis of the bioaerosol size distribution showed that microbial propagules that reach both the upper and lower respiratory tract may evoke numerous adverse health effects from irritation and asthmatic reactions to allergic inflammation. A comparative analysis of viable and total airborne microbial counts showed that viable micro-organisms accounted for up to 0.3% of the total number of microbial propagules. Hence, a comprehensive hygienic assessment of office workplaces should include an efficient control of both these elements.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 4; 465-476
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologiczna jakości powietrza w zakładach piekarniczych
The assessment of microbiological indoor air quality in bakeries
Autorzy:
Wołejko, E.
Kowaluk-Krupa, A.
Wydro, U.
Butarewicz, A.
Jabłońska-Trypuć, A.
Piekut, J.
Dec, D.
Łoboda, T.
Powiązania:
https://bibliotekanauki.pl/articles/399933.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
piekarnie
bakterie
grzyby
zanieczyszczenie powietrza
bacteria
fungi
indoor air quality
bakeries
Opis:
Celem niniejszej pracy była ocena stanu jakości mikrobiologicznej powietrza w zakładach piekarniczych zlokalizowanych na terenie województwa podlaskiego. Badania wykonano jesienią 2014 roku na terenie trzech zakładów piekarniczych. Próby powietrza pobierano metodą zderzeniową z użyciem próbnika powietrza MAS-100 (Merck, Niemcy). Mikrobiologiczne badania powietrza obejmowały oznaczenie ogólnej liczby bakterii psychrofilnych i mezofilnych, bakterii wskaźnikowych tj. bakterii z gatunku Pseudomonas fluorescens, gronkowców mannitolododatnich i manitoloujemnych oraz grzybów pleśniowych znajdujących się w powietrzu atmosferycznym. Zanieczyszczenie powietrza wewnętrznego w badanych piekarniach pod kątem mikrobiologicznym różniło się w zależności od rodzaju lokalizacji zakładu produkcyjnego. Stężenia występujących wewnątrz zakładów bakterii mezofilnych i Staphylococcus mannitolododatnich oraz mannitoloujemnych przekraczały wartości graniczne określone dla powietrza niezanieczyszczonego. Nie odnotowano natomiast w analizowanych piekarniach nadmiernego zanieczyszczania powietrza grzybami pleśniowymi. Najwyższą liczbę grzybów w powietrzu wykryto w piekarni 1, natomiast w pozostałych piekarniach ich liczba utrzymywała się na poziomie czystego powietrza atmosferycznego.
The aim of this study was to assess microbiological indoor air quality of selected bakeries located in the region of Podlasie. The microbiological studies were conducted in autumn in 2014 in three selected bakeries. Microbiological air counts were measured by impaction using an air sampler MAS-100 NT. The microbiological air studies, comprised the determination of the total number of psychrophilic and mesophilic bacteria, namely indicator bacteria such as: bacteria of the species Pseudomonas fluorescens, mannitol-positive and mannitol-negative Staphylococc, the total number of bacteria from the Enterobacteriaceae family and fungi found in atmospheric air. The results of the study of indoor air polluted with the analyzed groups of microorganisms differed depending on the type of test air and the location of the manufacturing plant. In the plants, the concentration of mesophilic bacteria and mannitol–positive and mannitol-negative Staphylococcus exceeded the limit values of unpolluted air, according to the Polish Standard recommendations.
Źródło:
Inżynieria Ekologiczna; 2016, 47; 182-188
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenia ozonu w pomieszczeniach przeznaczonych na czasowy pobyt ludzi
Ozone concentrations in Lublin non-occupational environments
Autorzy:
Staszowska, A.
Dudzińska, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/127306.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ozon
powietrze wewnętrzne
jakość powietrza wewnętrznego
ozone
indoor air
indoor air quality
non-occupational environments
Opis:
Badania przeprowadzono w pomieszczeniach przeznaczonych na czasowy pobyt ludzi: w pokojach biurowych i punktach kserograficznych zlokalizowanych na terenie miasta Lublina. Badania stężenia ozonu w powietrzu wewnętrznym przeprowadzone zostały w dwóch okresach: w okresie letnim i w sezonie grzewczym. Próbki do badań pobierano metodą pasywną. Pomiaru stężenia ozonu dokonano metodą spektrofotometryczną. Stężenia ozonu dla okresu letniego wyniosły: 0,01 -K),04 mg/m3 dla pomieszczeń biurowych oraz 0,008+0,176 mg/m3 dla punktów kserograficznych. Natomiast w sezonie grzewczym stężenia ozonu kształtowały się w następujących przedziałach: 0,007+0,018 mg/m3 dla pomieszczeń biurowych i 0,001-K),015 mg/m3 dla punktów kserograficznych. W punktach kserograficznych dopuszczalne stężenie 0,15 mg/m3 zostało przekroczone w sezonie letnim w dwóch przypadkach. W sezonie grzewczym nie odnotowano przekroczenia dopuszczalnego stężenia w punktach kserograficznych. W przypadku pomieszczeń biurowych dopuszczalne stężenie wynoszące 0,15 mg/m3 nie zostało przekroczone.
Ozone is the common component of indoor air. Because of its high reactivity it plays an important role in forming of indoor air quality, which influence directly on health of interior occupants. It is a well-known fact, that ozone can damage the respiratory system, inflames and irritates respiratory tissues, and can worsen asthmatic symptoms in individuals with asthma. Ozone exposure can produce symptoms such as coughing, chest tightness and impaired breathing. Elevated exposures have the potential to induce permanent lung damage, and even increase the risk of premature death in persons with poor health. Hence, there is a need to measure the concentrations of ozone in indoor air environments. The indoor ozone concentration depends on the outdoor ozone concentrations, the rate at which indoor air is exchanged with outdoor air, interior air circulation, indoor sources of ozone (eg ozone generators, electrostatic air cleaners, photocopiers, and laser printers), the rate at which ozone is removed by indoor surfaces, and reactions between ozone and other chemicals in the air. The objective of this study was to examine ozone concentrations in indoor air in selected non-occupational environments: office rooms and Xerox service points. Summer time and cold (heating) season was examined. Samples were collected using passive method. The ozone concentration on summer time was within the range of 0.04-K).01 mg/m3 for office rooms and 0.008-0.176 mg/m3 for Xerox points. In two examined Xerox places the permitted level of ozone (0.15 mg/m3) was exceeded in summer time. In cold time the permitted level of ozone was not exceeded in any Xerox points. hi offices rooms the permitted level of ozone was not achieved.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 623-627
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of indoor air quality in a store with additional gas heater
Autorzy:
Wysocka, Monika
Załuska, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1177489.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
air pollution
carbon dioxide
gas heater
heating
indoor air quality
thermal comfort
ventilation
Opis:
The quality of the internal environment is an extremely important issue, because users of rooms spend a significant part of the day inside buildings. The quality of the environment is largely dependent on the quality of the indoor air. The parameters of the air we breathe affect our health and the comfort of use of the rooms. Poor indoor air quality can cause a decrease in human comfort and various illnesses and ailments. Therefore, care should be taken to ensure adequate ventilation in the rooms, especially those that have an additional source of pollutant emissions. The purpose of this work is to examine the effect of heating a commercial premises room with a gas heater on air quality. The following parameters were measured as part of the tests: carbon dioxide concentration, air temperature and relative air humidity. The most important parameter significantly affecting the deterioration of the quality of the interior microclimate is carbon dioxide, the level of which reached high values, well above the hygienic minimum (1000 ppm). In order to compare the values of the tested parameters, the measurements were carried out in two options - for a period of five days with the stove running and another two days without additional heating.
Źródło:
World Scientific News; 2018, 102; 209-216
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air Filtration and Sterilization in Ventilation Systems According to the New Paradigm
Autorzy:
Cepiński, Wojciech
Szałański, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2202141.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pathogen
filtration
ventilation
indoor air pollution
indoor air quality
COVID-19
SARS-CoV-2
air handling unit
Opis:
The paper deals with the subject of increasing the efficiency of air purification in ventilation systems in situations of unusual hazardous indoor air pollutants. It analyzes possible locations of additional filtering and sterilizing elements in the installation to eliminate their return to the rooms. The quantities of pollutants in particular parts of the system were determined for a given fan configuration in the air handling unit and a possible leakage in the heat recovery system. Guidelines were proposed for the design and construction of systems to enable rapid modification of systems in the event of unusual contamination or pathogens in the indoor air.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 25--34
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroorganizmy w kurzu z pomieszczeń na przykładzie miasta Lublina
Characterization of the microbial community in settled dust samples from indoor environments in Lublin
Autorzy:
Staszowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126364.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikroorganizmy
powietrze wewnętrzne
kurz domowy
jakość powietrza wewnętrznego
microorganisms
indoor air
house dust
indoor air quality
Opis:
W pracy jest przedstawiona charakterystyka mikrobiologiczna próbek kurzu zebranych w pomieszczeniach mieszkalnych i placówkach edukacyjnych zlokalizowanych na obszarze miasta Lublina. W kurzu najczęściej spotykanymi bakteriami były pałeczki Gram-dodatnie. Większość należała do rodzaju Bacillus. W próbkach kurzu z placówek edukacyjnych największą koncentrację bakterii stanowił gatunek Bacillus subtillis. Największą grupę po pałeczkach Gram-dodatnich spotykanych w kurzu były ziarniaki Gram-dodatnie. Głównie był to rodzaj Micrococcus, a dominującym gatunkiem był Micrococcus luteus. W kurzu znajdywały się także Gram-dodatnie ziarniaki z rodzaju Staphylococcus oraz Gram-ujemne pałeczki. W przypadku grzybów zawartych w kurzu dominującymi rodzajami były Aspergillus (głównie gatunek Aspergillus nigerii) oraz Penicillium. Grzyb z rodzaju Cladosporium był także spotykany w badanych próbkach.
Dust particles collected from indoor environments may contain hundreds of chemically and biologically active components, which can cause many adverse health effects and deterioration of building materials. While all types of microorganisms can cause problems indoors, bacteria and fungi are most commonly associated with indoor air quality complaints. Some of them produce mucus and excrete chemicals which can provoke allergy, respiratory system and skin irritation, headache, or fatigue. This study was designed to obtain information about characterization of the microbial community in settled dust samples from indoor environments of the Lublin area. Dust samples were collected from households and educational establishments. Microbial species and their concentrations were determined by culture analysis. The concentrations and proportions of morphologically distinguishable culturable bacteria and fungi in dust samples was as follows. In case of bacteria the most commonly found were Gram-positive rods, predominantly Bacillus spp. (Bacillus subtillis) and cocci - genus Micrococcus (Micrococcus leutus) and Staphylococcus. Fungi were represented by genus Aspergillus (mainly Aspergillus nigerii), Penicillium, and Cladosporium. Additionally, microbial concentrations of similar environments vary between sample types, eg total amount of fungi has been higher in dust from textile covered floor than in samples from bare floor.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 325-328
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu środowiska wewnętrznego w wybranych przedszkolach. Cz. 1 Temperatura
Analysis of indoor environment in a kindergarten building. P. 1 Temperature
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403027.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
jakość powietrza wewnętrznego
wentylacja
mikroklimat
temperatura
indoor air quality
ventilation
microclimate
temperature
Opis:
Aby zapewnić dzieciom odpowiednie warunki sanitarno-higieniczne w pomieszczeniach przedszkolnych należy pamiętać o częstym wietrzeniu i nie przegrzewaniu pomieszczeń. Aby zapewnić dzieciom odpowiednie warunki sanitarno-higieniczne w pomieszczeniach należy więc zapewnić właściwą wentylację. Temperatura w pomieszczeniach jest parametrem stanu powietrza najbardziej odczuwalnym przez ludzi. Decyduje ona o samopoczuciu, wydajności w pracy, zapewnia tzw. komfort cieplny. Niewłaściwa temperatura, może doprowadzić do chorób. Badania prowadzono w trzech przedszkolach o różnej wielkości i różnej termoizolacyjności ścian zewnętrznych. Termomodernizację w poszczególnych przedszkolach wykonano w różnym czasie. Prowadzono badania jakości powietrza wewnętrznego w salach przedszkolnych. W artykule przedstawiono tylko wyniki dotyczące temperatury powietrza wewnętrznego badanych przedszkoli.
In order to ensure proper sanitary and hygienic conditions in a kindergarten building, one needs to remember about airing the rooms frequently and making sure that the temperature is not too high; this is why an efficient ventilation system is indispensable. Temperature is the parameter of indoor air whose influence people are most likely to feel. It is the decisive factor about their general physical and mental state and the efficiency of their work; temperature also ensures the socalled thermal comfort. A temperature that is either too high or too low may cause various diseases. The research was conducted in three kindergartens which varied in terms of the space of the facilities and thermal insulation of exterior walls. Thermomodernization in each kindergarten was carried out at a different time. The research focused on the quality of indoor air in particular rooms. This article discusses the results only with regard to air temperature in the kindergartens in question.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 4; 281-285
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry powietrza podczas pracy lakierni autobusowej na wybranym przykładzie
Air quality parameters during the operation of a bus paint shop on the basis of a selected example
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/315602.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
wentylacja
lakiernik
jakość powietrza wewnętrznego
ventilation
car paint shop
indoor air quality
Opis:
Zasadniczą treść tego artykułu stanowi przedstawienie parametrów powietrza wentylacyjnego, które wystąpiły podczas ich pomiarów, przeprowadzonych w czasie pracy lakierni autobusowej. Przedstawiono rozkłady temperatur, wilgotności względnej, prędkości ruchu powietrza w lakierni oraz stężenia dwutlenku węgla, a także wyciągnięto wnioski z wyników pomiarów. Omówiono także zagadnienia, związane z komfortem cieplnym oraz jego wpływem na warunki pracy pracownika w lakierni. Szczególny nacisk położono na scharakteryzowanie wpływu dwutlenku węgla na organizm ludzki. Zawarto również informacje o dopuszczalnych wartościach tego trującego gazu w pomieszczeniach lakierni, wynikające z obowiązujących przepisów.
The principal part of this paper is concerned with the presentation of air quality parameters and ventilation rates, which were registered during measurements conducted in a bus paint shop. The presentation includes the distribution of temperatures, relative humidity, velocity of air circulation in a paint ship along with concentration of carbon dioxide coupled with conclusions from the conducted measurements. In addition, the presentation includes the issues associated with thermal comfort and its impact on the working conditions in a paint shop. The paper also contains information regarding the maximum admissible levels of this pollutant on the premises of a paint shop, according to the regulations in force.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 199-203, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor and Outdoor Concentrations of Particulate Matter and Gaseous Pollutants on Different Floors of a University Building: A Case Study
Autorzy:
Cichowicz, Robert
Dobrzański, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1839306.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
air quality monitoring
VOCs
H2S
PM10
PM2.5
indoor air quality
outdoor air quality
Opis:
In this study, we investigate the changes in the concentrations of suspended particulate matter (PM10 and PM2.5) and selected gaseous pollutants (VOCs, H2S) in the atmospheric air inside and outside a 9-story building, which is intended primarily for the teaching activities. The purpose was to determine whether the air quality inside the building is directly dependent on the outside air quality. The analysis also included the influence of the height of the building, its location and environment, as well as meteorological conditions. No clear correlation was found between the measured parameters inside and outside the building. The height above ground (the floor on which the measurements were made) was found to have a significant influence on the concentration of each pollutant. Wind direction was also found to have a very important impact on the air quality inside the building. A strong relationship was observed on the leeward side between the concentration of impurities on the inside and outside of the building.
Źródło:
Journal of Ecological Engineering; 2021, 22, 1; 162-173
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Indoor Air Quality in Offices and Classrooms in Public Utility Building - a Case Study
Autorzy:
Łuszczyńska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/27314787.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
indoor air quality
bioaerosol
microorganisms
fungi
jakość powietrza w pomieszczeniach
bioaerozol
mikroorganizmy
grzyby
Opis:
A microbiological analysis of indoor air quality in offices, lecture rooms, and hallways in a public utility building has been carried out in the Lubuskie Voivodship (Poland). In one of the storage rooms, the presence of fungi on the building partition was found in the place of water infiltration as a result of a technological failure in the building. A total of 17 nonresidential interiors were examined. The total number of psychrophilic and mesophilic bacteria and the total number of fungi were sampled by the collision method with the air sampler. A qualitative analysis has been performed of fungi present in the indoor air and from building partition of the studied interiors. A total of 11 species of fungi have been specified. Relative humidity and air temperature were measured with a hygrometer. The studies showed that the number of psychrophilic bacteria in indoor air was in the range 0-730 CFU/m3 , while the number of mesophilic bacteria was slightly higher (0-896 CFU/m3 ). A high level of contamination and a large number of fungi (734 CFU/m3 ) were found in the indoor air of storage room, where the problem of biodeterioration of building partitions occurred. In the remaining rooms, the level of microorganisms was low or moderate. Microbiological tests of the outdoor air (background) did not reveal an excessive number of microorganisms in the air.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 3; 228--239
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozkład wybranych parametrów powietrza w hamowni samochodowej
Variability of selected air parameters in the premises containing a car dynamometer
Autorzy:
Gużda, A.
Szmolke, N.
Powiązania:
https://bibliotekanauki.pl/articles/315419.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
jakość powietrza wewnętrznego
dwutlenek węgla
hamownia
indoor air quality
carbon dioxide
car dynamometer
Opis:
W artykule scharakteryzowano pracę hamowni samochodowych omawiając szczegółowo ich rodzaje i przeznaczenie. Wskazano między innymi na warunki pracy w pomieszczeniach, w których znajdują się tego typu urządzenia diagnostyczne. Przedstawiono także podstawowe informacje o komforcie cieplnym, jaki należy stworzyć diagnostom realizującym swoje zadania w hamowni. Duży nacisk położono na omówienie szkodliwości występowania nadmiernego stężenia CO2 w pomieszczeniach i jego wpływ na organizm ludzki. W części eksperymentalnej zawarto informacje o zmierzonych parametrach powietrza wewnętrznego w hamowni, takich jak temperatura, wilgotność względna i stężenie dwutlenku węgla. Uzyskane wyniki pozwoliły na wyciagnięcie wniosków z których wynika, że zaistniałe podczas pracy hamowni warunki powietrza w pomieszczeniu nie odbiegały znacząco od prawidłowych. Wskazano także na konieczność wykonania dalszych badań.
The paper discusses the operation of a car dynamometer and includes details of its types and the designated use. Among other things, the conditions of operation in the premises containing diagnostic devices are indicated. The basic information about the thermal comfort, which needs to be secured for the work of diagnosticians performing their duties in the premises containing a dynamometer. An emphasis is placed on the discussion of the hazard posed by the excessive CO2 concentrations in the premises and its effects on the human body. The experimental part of the paper contains information regarding the measured parameters of internal air in the rooms containing a dynamometer, such as temperature, relative humidity and carbon dioxide concentration. The results enabled the statement of the conclusions which indicate that the ambient air conditions in the premises do not differ significantly from the acceptable results. The need to conduct further studies is also indicated.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 204-208, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunki rozwoju pomiarów zapachu i zawartości związków mVOC we wnętrzach budynków
Trends in odour measurements and determining mVOC content in the interiors of buildings
Autorzy:
Kostyrko, K. B.
Kozicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/267570.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odorant
powietrze wewnętrzne
moc
indoor air quality
IAQ
microbial volatile organic compounds
mVOC
Opis:
Praca zawiera zestawienie współczesnych technik służących do pomiarów zapachu jak również dopuszczalnych poziomów stężeń substancji uciążliwych zapachowo występujących we wnętrzach budynków. Scharakteryzowano lotne związki organiczne pochodzenia mikrobiologicznego, odpowiedzialne za różnego rodzaju zapachy, jak również techniki analityczne służące do ich chemicznej charakterystyki. Szczególną uwagę poświęcono elektronicznym nosom, będącym coraz powszechniejszymi, często przenośnymi, urządzeniami służącymi do monitorowania stężenia odorantów zapewniającymi analizę w czasie rzeczywistym.
The work summarizes contemporary techniques for odour measurements as well as permissible levels of concentrations of odorous substances occurring in the interiors of buildings. Microbial volatile organic compounds which are responsible for various smells have been characterized. The most suitable techniques for sampling and MVOC chemical characterization in indoor environments were reviewed. The olfactometric techniques are discussed and the strong and weak points of odour assessment through human detection are highlighted. Particular attention was paid to electronic noses, which are increasingly common, often portable, devices for monitoring the concentration of odorants providing real-time analysis.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 97-102
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort in university computer laboratories
Komfort cieplny w pracowniach komputerowych uczelni wyższej
Autorzy:
Telejko, M.
Stachera, A.
Powiązania:
https://bibliotekanauki.pl/articles/402042.pdf
Data publikacji:
2018
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
PMV
PPD
microclimate
indoor air quality
komfort cieplny
mikroklimat
jakość powietrza wewnętrznego
Opis:
Thermal comfort defines the state of satisfaction of a person or a group of people with thermal conditions of the environment in which the person, or the group of people is staying. The state of satisfaction depends on the balance between the amount of heat produced by the organism in the process of metabolism and heat loss from the organism to the surrounding environment. It has an effect on the quality and efficiency at work, and indirectly also on the presence of symptoms of Sick Building Syndromes (SBS). Due to differences in body structure, metabolism, clothing etc., it is not possible to create a satisfactory thermal environment for all the people staying in it. However, there are parameter values, which maintained at an appropriate level, allow to meet thermal expectations of even 95% of people staying in this environment. The article presents the results of tests conducted in the university computer rooms. The studies included measurements and analysis of typical internal microclimate parameters: temperature, relative humidity and CO2 concentration. The results raised considerable reservations and therefore in order to assess fully the conditions of use, it has been decided to conduct evaluation of thermal comfort in rooms analysed. In addition, the surrounding surface radiation temperature and clothing insulation of users have been specified. On the basis of the obtained data, PPD and PMV index values were determined in accordance with the standard EN ISO 7730:2005 Ergonomics of the thermal environment – Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria [3].
Komfort cieplny określa stan zadowolenia osoby lub grupy osób z warunków termicznych środowiska, w którym osoba ta lub grupa osób przebywa. Ten stan zadowolenia zależny jest od równowagi pomiędzy ilością ciepła wytwarzanego przez organizm w procesie metabolizmu a stratami ciepła z organizmu do otaczającego go środowiska. Ma on wpływ na jakość i wydajność pracy, a pośrednio również na występowanie symptomów syndromów chorego budynku (SBS). Na skutek różnic w budowie ciała, metabolizmie, ubiorze etc. nie ma możliwości stworzenia środowiska cieplnego odpowiadającego wszystkim przebywającym w nim osobom. Istnieją jednak wartości parametrów, które utrzymane na odpowiednim poziomie, pozwalają na spełnienie oczekiwań termicznych nawet 95% ludzi przebywających w tym środowisku. W artykule zaprezentowano wyniki badań przeprowadzonych w pomieszczeniach komputerowych uczelni wyższej. Badania obejmowały pomiary oraz analizę typowych parametrów mikroklimatu wewnętrznego: temperatury, wilgotności względnej oraz stężenia CO2. Uzyskane wyniki budziły spore zastrzeżenia, dlatego w celu pełnej oceny warunków użytkowania zdecydowano się na przeprowadzenie oceny komfortu termicznego analizowanych pomieszczeń. Dodatkowo określono zatem temperaturę promieniowania powierzchni otaczających i izolacyjność odzieży użytkowników. Na podstawie otrzymanych danych wyznaczono wartości wskaźników PPD i PMV, zgodnie z normą EN ISO 7730:2005 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria [3].
Źródło:
Structure and Environment; 2018, 10, 3; 201-210
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu środowiska wewnętrznego w wybranych przedszkolach. Cz. 2 Wilgotność względna
Analysis of indoor environment in a kindergarten building. P. 2
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/403031.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
jakość powietrza wewnętrznego
wentylacja
mikroklimat
wilgotność względna
indoor air quality
ventilation
microclimate
relative humidity
Opis:
Najczęstszym objawem problemów z wymianą powietrza jest nadmierny wzrost wilgotności, który jest konsekwencją źle działającej wentylacji. Wilgotność względna powietrza w pomieszczeniu powinna się mieścić w granicach 30-65%, optymalna - 40-50%. Przebadano trzy przedszkola o różnej izolacyjności ścian zewnętrznych, aby ocenić stan środowiska wewnętrznego z uwzględnieniem wilgotności względnej. Badania wszystkich przedszkoli prowadzono w trzech seriach pomiarowych. Wilgotność powietrza w listopadzie i lutym, w budynkach po termomodernizacji, była poniżej zalecanych wartości. Powietrze było suche, mimo dużej wilgotności względnej powietrza zewnętrznego. W przedszkolu nie poddanym termomodernizacji, bez względu na porę roku, powietrze wewnętrzne było wilgotne.
Excessive rise of humidity is the most frequently observed sign of problems with air circulation, which often result from a faulty ventilation system. Relative humidity value indoors should range from 30% to 65%, the ideal being between 40% and 50%. The research was conducted in three kindergartens with different insulation of exterior walls; the objective was to assess the quality of indoor air with regard to relative humidity. Three series of measurements were taken in each of the kindergartens. In the building where thermomodernization was carried out, humidity values in February and November dropped below the recommended ones. Even though outdoor relative humidity was high, indoor air in this kindergarten was dry. In the kindergarten whose heating system has not been modernized, humidity values inside the building were appropriate regardless of the season.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 4; 287-291
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort measurements in the Energis building
Badania komfortu cieplnego w budynku Energis
Autorzy:
Białek, Anita
Koltuk, Bade
Powiązania:
https://bibliotekanauki.pl/articles/2055091.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
indoor air quality
thermal comfort
thermal responses
jakość powietrza wewnętrznego
komfort cieplny
odczucia cieplne
Opis:
In the paper the measurements of thermal comfort in the modern smart building “Energis” have been presented together with their analysis. The data have been obtained in the spring and the analyses of indoor air parameters as well as subjective responses of the volunteers have been conducted. Based on the performed studies it has been concluded that the people felt fine in the considered room (pleasantly warm, cool and comfortable) and described their feelings as acceptable and comfortable.
W artykule przedstawiono wyniki badań i analizę komfortu cieplnego w budynku inteligentnym „Energis”. Dane eksperymentalne uzyskano w okresie wiosennym, a analiza dotyczyła parametrów powietrza wewnętrznego, jak również subiektywnych odczuć ochotników. W oparciu o przeprowadzone badania można stwierdzić, że użytkownicy czuli się dobrze w rozpatrywanym pomieszczeniu (przyjemnie ciepło i chłodno, a także komfortowo) i ocenili swoje odczucia jako akceptowalne i komfortowe.
Źródło:
Structure and Environment; 2021, 13, 1; 10--15
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba poprawy jakości powietrza wewnętrznego w przedszkolu
Indoor air quality in a preschool
Autorzy:
Koruba, D.
Zender-Świercz, E.
Piotrowski, J.Z.
Orman, Ł.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/390993.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
Opis:
W artykule przedstawiono wyniki badań nad jakością powietrza wewnętrznego (IAQ) w jednym z wybranych przedszkoli. W obiekcie zastosowany został system wentylacji grawitacyjnej. Wstępne badania potwierdziły niską jakość powietrza wewnętrznego w podmiotowym budynku. W trakcie badań zaproponowano dwa usprawnienia mające na celu poprawę jakości powietrza: zwiększenie strumienia powietrza nawiewanego oraz, w drugiej kolejności, montaż urządzeń do uzdatniania powietrza wewnętrznego. Uzyskane wyniki badań wskazują, że wprowadzone usprawnienia wpływają na poprawę jakości powietrza wewnętrznego.
The article demonstrates the results of research on the indoor air quality (IAQ) in one of chosen preschools. In such facilities, the standard solution is a system of natural ventilation. Only a small percentage of such buildings is equipped with a mechanical ventilation system with adjustable parameters of the microclimate. The article presents the results of indoor air quality in the local preschool located in Kielce. In the present facility natural ventilation system was used. Preliminary studies confirmed the poor quality of indoor air in a subjected building. During the study, two improvements aimed at improving air quality were proposed. The first improvement was to increase the supply air stream. The second one concerned the installation of equipment for the treatment of indoor air. The results indicate that under certain guidelines it is possible to improve indoor air quality. As an indicator of indoor air quality, concentration of carbon dioxide was adopted. In addition, microbiological tests were performed indoors.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 7-13
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość powietrza w wielorodzinnych budynkach mieszkalnych
Indoor air quality in multifamily buildings
Autorzy:
Telejko, M.
Zender–Świercz, E.
Piotrowski, J.Z.
Powiązania:
https://bibliotekanauki.pl/articles/390643.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
jakość powietrza wewnętrznego
mikroklimat
wymiana powietrza
fizyka budowli
indoor air quality
microclimate
air exchange
building physics
Opis:
Obowiązujące aktualnie przepisy prawne regulujące zagadnienia wentylacji naturalnej [1], [2], [3] w wielu obszarach są niejednoznaczne, a niekiedy wręcz sprzeczne. Sytuacja taka prowadzi do stosowania rozwiązań powodujących poważne zaburzenia w działaniu wentylacji grawitacyjnej. W dużej części budynków zaburzenia te są wynikiem dostarczania do pomieszczeń zbyt małej ilości powietrza zewnętrznego. Jak wykazały badania, ze względu na kształtowanie warunków mikroklimatu wnętrz, podstawowe znaczenie ma nie tylko wielkość dostarczanego strumienia powietrza zewnętrznego, ale również rozmieszczenie elementów doprowadzających to powietrze.
The applicable legislation connected with the natural ventilation are ambiguous and sometimes contradictory. This leads to serious problems with natural ventilation. In most cases malfunction of the natural ventilation is due to the insufficient stream of air from the outside. The research showed that the microclimate is influenced not only by the incoming air stream, but also by the layout of the air supply.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 67-74
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary test results of thermal comfort in a classroom
Wstępne wyniki badań komfortu cieplnego w sali lekcyjnej
Autorzy:
Krawczyk, Natalia
Piasta, Zdzisław
Powiązania:
https://bibliotekanauki.pl/articles/402066.pdf
Data publikacji:
2019
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
indoor air quality
thermal sensations
komfort cieplny
jakość powietrza w pomieszczeniu
odczucia termiczne
Opis:
The paper presents the issue of thermal comfort based on the conducted study. First, the definition and importance of thermal comfort was discussed. Then, air parameters were measured and surveys were conducted regarding questions about the assessment of thermal comfort of persons using the room. The list of the subject thermal comfort evaluation tests are illustrated in the diagrams. The impact of gender and BMI on the Predicted Mean Vote PMV were also analyzed. In the next part, results obtained from surveys and according to formulas from the standard were developed, and then compared.
W pracy przedstawiono zagadnienie komfortu cieplnego w oparciu o przeprowadzone badanie. Najpierw omówiono definicję i znaczenie komfortu cieplnego. Następnie wykonano pomiary parametrów powietrza oraz przeprowadzono ankiety dotyczące pytań o ocenę komfortu cieplnego osób użytkujących pomieszczenie. Zestawienia badań oceny komfortu cieplnego zilustrowano na wykresach. Analizie poddano także wpływ płci i wskaźnika BMI na przewidywaną średnią ocenę PMV. W kolejnej części opracowano wyniki otrzymane z ankiet oraz według wzorów z normy, a następnie je porównano.
Źródło:
Structure and Environment; 2019, 11, 4; 281-286
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal comfort in intelligent buildings
Komfort cieplny w budynkach inteligentnych
Autorzy:
Majewski, G.
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/402098.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
smart building
thermal comfort
indoor air quality
inteligentny budynek
komfort termiczny
jakość powietrza w pomieszczeniach
Opis:
The paper presents the issue of thermal comfort conditions with regard to intelligent buildings. First the principles of thermal comfort are discussed, namely the parameters affecting the human perception of the best indoor air conditions. Among the mentioned parameters indoor temperature seems to be especially vital for humans. In the second part the test results of temperature changes in the Energis building are presented together with the discussion.
Źródło:
Structure and Environment; 2016, 8, 1; 25-30
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Empirical cumulative distribution function of CO2 concentration increments as a descriptor of indoor air variability
Autorzy:
Szczurek, A.
Maciejewska, M.
Pietrucha, T.
Powiązania:
https://bibliotekanauki.pl/articles/208271.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
carbon dioxide
air quality
carbon
indoor air pollution
indoor air quality
indoor environment
dwutlenek węgla
jakość powietrza
węgiel
zanieczyszczenie powietrza w pomieszczeniach
jakość środowiska wewnętrznego
środowisko wewnętrzne
Opis:
Indoor air quality broadly refers to the environmental characteristics inside buildings and characterizes the physical, chemical and biological state of indoor air at some place and time. Usually it is characterized by physicochemical properties of indoor environment such as temperature, relative humidity, airflows and concentration of characteristic pollutants, e.g. carbon dioxide. They are highly variable in time. In the paper, changes of empirical cumulative distribution function (ECDF) of CO2 concentration were considered as a descriptor of indoor air variability. Using this measure, there may be performed the analysis of CO2 variation in a short as well as long term. The approach utilizes the idea of classification. A class of variation of CO2 concentration has its individual ECDF. It indicates a particular case of balance/imbalance between CO2 delivery and removal processes, including gas dispersion. The analysis is applicable for evaluating the stability of indoor environment and it may provide support for the diagnosis of the performance of the air exchange system. Exemplary results were provided for an open space office and a lecture theater.
Źródło:
Environment Protection Engineering; 2015, 41, 3; 173-187
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości powietrza wewnętrznego w wybranych przedszkolach
Indoor air quality in a preschool
Autorzy:
Telejko, M.
Powiązania:
https://bibliotekanauki.pl/articles/391209.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
fizyka budowli
wentylacja
wymiana powietrza
jakość powietrza wewnętrznego
building physics
ventilation
air exchange
indoor air quality
preschool building
Opis:
W artykule przedstawiono wyniki badań jakości powietrza wewnętrznego przeprowadzonych w 4 przedszkolach samorządowych. W rozpatrywanych obiektach zastosowany został system wentylacji grawitacyjnej. Uzyskane wyniki badań wskazują jednoznacznie na bardzo niską jakość powietrza w tego typy budynkach.
The article presents the results of indoor air quality (IAQ) assessment in four local preschools. The natural ventilation system was used in the buildings. Outdoor air was supplied to the premises through a leak in the external walls and air intakes were of maximum efficiency of 30 m3/h. Parameters describing IAQ were measured, such as: temperature, relative humidity and carbon dioxide concentration. Two series of studies were performed in each preschool. On the basis of the survey, it can be clearly stated that the indoor air quality in preschools is considered to be very low very low. All the analyzed parameters describing the quality do not meet the current legal requirements. Reported values of CO2 concentration exceeded three times the value set of the recommended maximum.
Źródło:
Budownictwo i Architektura; 2014, 13, 4; 41-48
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies