Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "dokladnosc" wg kryterium: Temat


Tytuł:
The Accuracy of EGNOS (ESTB) in Poland - the system performance tests in the position domain
Autorzy:
Cydejko, J.
Powiązania:
https://bibliotekanauki.pl/articles/320819.pdf
Data publikacji:
2005
Wydawca:
Polskie Forum Nawigacyjne
Tematy:
EGNOS
dokładność
accuracy
Opis:
In the year 2005 the EGNOS enters the Operational Readiness Review phase becoming available for users in its almost full capability. It may be expected that very soon EGNOS will find significant interest among many users and will find many applications all over the Europe. The paper presents the summary of the tests of satellite positioning with using EGNOS (ESTB) signal conducted by author in the area of the Polish coast of the Baltic Sea during several years since 2001 till now. The results of conducted tests show the EGNOS (ESTB) performance at the edge of the nominal system coverage, verifying, in the experimental way, the predicted system accuracy and the efficiency of WADGPS EGNOS algorithms in this area. Additionally, the comparison of the results obtained during the subsequent years of the system development shows the gradual improvement in system performance coming with increased number of RIMS and the evolution from the EGNOS System Test Bed to the fully capable EGNOS.
Źródło:
Annual of Navigation; 2005, 10; 5-21
1640-8632
Pojawia się w:
Annual of Navigation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zniesienia selektywnego zakłócenia na dokładność określania pozycji za pomocą systemu DGPS
The influence of the annulment of selective availability on the accuracy of position qualifying in the DGPS system
Autorzy:
Bober, R.
Szewczuk, T.
Wolski, A.
Powiązania:
https://bibliotekanauki.pl/articles/906822.pdf
Data publikacji:
2006
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
dokładność DGPS
DGPS accuracy
Opis:
W artykule przedstawiono wyniki badań dokładności określania pozycji za pomocą systemu DGPS przy wykorzystaniu poprawek transmitowanych przez radiolatarnie Dziwnów i Hammerodde. Badania przeprowadzono w sześciu punktach zlokalizowanych w pobliżu Zalewu Szczecińskiego. Celem badań było określenie wpływu zniesienia selektywnego zakłócenia (S/A) na dokładność określania pozycji w systemie DGPS.
This article presents the results of assessing position determination accuracy of a DGPS system. Correction signals were transmitted from Dziwnow and Hammerodde reference stations. The research, including six locations in the vicinity of Zalew Szczecinski (The Szczecin Lagoon), aimed at the determination of how the elimination of selective availability affects position accuracy in a DGPS system.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2006, 8 (80); 5-15
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie dokładności instrumentów RTK GNSS w oparciu o standard ISO 17123-8
Examination of the accuracy of RTK GNSS receivers based on ISO 17123-8 standard
Autorzy:
Owerko, T.
Powiązania:
https://bibliotekanauki.pl/articles/131290.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
ISO
GNSS
test
dokładność
accuracy
Opis:
Tematem artykułu jest sprawdzenie odbiorników RTK GNSS [Leica SR530, Leica ATX1230 GG „SmartRover", Leica GX1230 i Topcon GR-3] według pełnej procedury testowej przewidzianej normą ISO 17123-8, w celu wyznaczenia oraz porównania parametrów mówiących o ich dokładnościach. Zgodnie z założeniami standardu opracowanie i przeprowadzenie testu obejmowało założenie bazy testowej w rejonie w który następnie badane odbiorniki mają być praktycznie wykorzystywane - okolice basenu AGH. W pracy przedstawiono warunki pomiaru [ilość satelitów, rozkład przeszkód na horyzoncie, itp.], a następnie przeprowadzono test odbiorników różnych producentów według ww. Normy, wykonano obliczenia i przeprowadzono testy statystyczne dzięki którym określono ich docelową przydatność. Istotnym elementem, który wykorzystano w trakcie testu, było założenie i skonfigurowanie pernamentnie pracującej stacji referencyjnej z oprogramowaniem Leica Spider [platforma MS Windows] oraz wariantowo Standard Ntrip Broadcaster BKG [platforma Ubuntu Linux], którą wcześniej założono w budynku C-4 AGH. Posłużyła ona jako stacja bazowa do dystrybucji poprawek RTK poprzez systemy GSM [protokół internetowy NTRIP] w trakcie wykonywania testu odbiorników.
The subject of this article is the examination of RTK GNSS receivers [Leica SR530, Leica ATX1230 GG "SmartRover, GX1230 and Leica Topcon GR-3] according to the full test procedure provided by ISO 17123-8, in order to determine and compare their accuracy parameters. According to the assumption given by the standard, the development and performance of the test covered the establishment of bases in the test area, in which the receivers were to be tested and used in practice (around the University pool). The paper presents measurement conditions [the number of satellites, the distribution of obstacles on the horizon, etc.], followed by tests of various brand receivers conducted to ISO 17123-8, as well as calculations and statistical tests, which helped to identify the usefulness of particular receivers. An important element that was used during the test included the establishing and configuring of a reference station, operating on an ongoing basis, with Leica Spider software [MS Windows platform], or alternatively Standard Ntrip Broadcaster BKG [Ubuntu Linux platform], which was established earlier in the C-4 building of the University. The station was used as a base for the distribution of RTK corrections by means of GSM systems [NTRIP Internet Protocol], in the course of the test.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2009, 19; 341-350
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry cieplne wpływające na dokładność modelowania procesu nagrzewania indukcyjnego
Thermal parameters influence on accuracy of induction heating process modeling
Autorzy:
Wesołowski, M.
Skrzypczak, P.
Hauser, J.
Powiązania:
https://bibliotekanauki.pl/articles/377111.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
nagrzewanie indukcyjne
modelowanie numeryczne
dokładność
Opis:
Obliczenia indukcyjnych układów grzejnych wymagają, w każdym przypadku, sprzężonych obliczeń pól elektromagnetycznych i cieplnych. W zagadnieniach praktycznych wykorzystywanych jest wiele modeli i procedur umożliwiających projektowanie procesów oraz urządzeń wykorzystujących nagrzewanie indukcyjne. Z uwagi na możliwość doświadczalnej weryfikacji wykonywanych analiz, problematyka ta jest szeroko opisywana oraz rozwijana. Tym niemniej, w wielu przypadkach, przyjmowanie uproszczeń w zakresie stosowanych modeli matematycznych, numerycznych oraz parametrów materiałowych, prowadzi do nadmiernego wzrostu błędów modelowania urządzeń tej klasy. W niniejszej pracy skupiono się na prezentacji najbardziej istotnych źródeł błędów modeli cieplnych, mogących występować podczas numerycznego modelowania układów wzbudnik – wsad, przeznaczonych do skrośnego nagrzewania indukcyjnego. Na podstawie wielowariantowych obliczeń określono dopuszczalny zakres analizowanych uproszczeń, gwarantujący wysoką dokładność modelowania indukcyjnych układów grzejnych.
Simulations of induction heating systems requires, in all cases, coupled computations of electromagnetic and thermal phenomena. In practice, a large number of different models and procedures are used to design the inductor – workpiece heating systems. Due to practical possibility of precise comparison between simulation and physical measurements results, the induction heating is very interesting. However, in many cases, simplifications of used mathematical models and material parameters lead to increase of simulations errors. In this article basic mathematical models of heat transfer phenomena in volumetric induction heating systems were presented. During calculations, results obtained using full models of thermal conduction, convection and radiation were compared to simplified authors models. Errors and the scope of applicability of simplified models were determined and discussed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 88; 239-250
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ osnowy na dokładności tyczenia w konstrukcjach jednoznacznych
Network influence on the setting out accuracy without additional observations
Autorzy:
Gmyrek, J.
Powiązania:
https://bibliotekanauki.pl/articles/262394.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
dokładność tyczenia
accuracy of setting out
Opis:
Praca przedstawia wyprowadzenie wzoru ujmującego wpływ niedokładności osnowy na dokładność tyczenia. Wzór odnosi się do tyczenia bez dodatkowych obserwacji. W tym przypadku macierz obserwacyjna musi być kwadratowa i musi mieć inwers. Pierwsza część wzoru zawiera tylko wpływ dokładności tyczenia, a część druga - wpływ dokładności osnowy. Ponadto w pracy podano ogólny przypadek wyprowadzenia wzorów na obie wymienione części.
The paper refers to derivation of the formula containing the influence of a network inaccuracy on the accuracy of setting out. The formula refers to setting out without additional observations. In this case the observation matrix must be square, and must have an inverse matrix. The first part of formula contains only the influence of accuracy of the setting out and the second part contains the influence of network accuracy. Besides a general case of derivation of the both parts of the formula was presented.
Źródło:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2006, 12, 2; 151-153
1234-6608
Pojawia się w:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptational Processes in Verbal Communication
Procesy adaptacyjne w komunikacji werbalnej
Autorzy:
Ophoff, Hans W.
Powiązania:
https://bibliotekanauki.pl/articles/18803825.pdf
Data publikacji:
1999
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
mechanizmy komunikacji
dokładność komunikacji
badania eksperymentalne
Źródło:
Acta Universitatis Lodziensis. Folia Psychologica; 1999, 03; 13-28
2353-4842
Pojawia się w:
Acta Universitatis Lodziensis. Folia Psychologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka systemu wspomagania pozycjonowania QZSS-Zenith
Characteristic of QZSS-Zenith positioning augmentation system
Autorzy:
Krasuski, K.
Powiązania:
https://bibliotekanauki.pl/articles/407837.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
QZSS-Zenith
QZSST
JGF
GPS
dokładność
accuracy
Opis:
W artykule przedstawiono charakterystykę japońskiego systemu nawigacyjnego QZSS-Zenith do wspomagania pozycjonowania satelitarnego. Scharakteryzowano poszczególne segmenty systemu QZSS-Zenith oraz opisano również skalę czasu i układ odniesienia w systemie QZSS. W części badawczej artykułu przedstawiono rezultaty pozycjonowania satelitarnego z użyciem obserwacji GPS i QZSS.
This paper presents characteristic of Japanese navigation system QZSS-Zenith for satellites positioning augmentation. Segments of QZSS-Zenith system were characterized, and time scale and reference frame of QZSS system were also described. The positioning results based on GPS and QZSS observations were presented in the research part of article.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 4; 58-62
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności parametrów ruchu statku spotkanego
Estimate of Accuracy of Parameter of Movement of a Counter Vessel
Autorzy:
Dziełak, E.
Jóźwicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/906317.pdf
Data publikacji:
2005
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
radar
dokładność
Inżynieria Ruchu Morskiego 2005
accuracy
Opis:
Przedstawiono matematyczny opis obliczania dokładności parametrów ruchu statku spotkanego oraz porównanie wymaganej dokładności zawartej w rezolucjach IMO, a także podano obliczenia teoretyczne.
This article includes a mathematical description of calculating the accuracy of movement parameters of an encountered vessel and a comparison of required accuracy specified in IMO resolutions and theoretical calculations.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2005, 6 (78); 77-84
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena precyzji i dokładności zmodyfikowanej metody oznaczania azotanów i azotynów w mleku
Evaluation of precision and accuracy of a modified method for determination of nitrates and nitrites in milk
Ocenka vosproizvodimosti I tochnosti modificirovannogo metoda opredelenija nitratov v moloke
Autorzy:
Przybylowski, T.
Kisza, J.
Nowicka, B.
Powiązania:
https://bibliotekanauki.pl/articles/873005.pdf
Data publikacji:
1983
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
azotany
azotyny
mleko
oznaczanie
metody
precyzja
dokladnosc
Źródło:
Roczniki Państwowego Zakładu Higieny; 1983, 34, 5-6
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Influence of Sample Averaging on Accuracy of Point Coordinates Measurement Performed Using Laser Tracking Systems
Autorzy:
Gruza, Maciej
Gąska, Piotr
Gąska, Adam
Harmatys, Wiktor
Jedynak, Michał
Kobiela, Konrad
Powiązania:
https://bibliotekanauki.pl/articles/102134.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Laser Tracker
measurement uncertainty
accuracy
niepewność pomiaru
dokładność
Opis:
Laser Tracking systems are commonly used in all branches of industry, which requires accurate large-scale measurements for instance aviation, space and shipbuilding industries. Laser Trackers belong to the group of non-Cartesian Coordinate Measuring Systems. Determination of the measured point coordinates involves the measurements of distance using laser beam and two angles recorded by horizontal and vertical encoders. Additionally, the environmental conditions are monitored and used for compensation of measured distance. The coordinates of single measured point are estimated using the results obtained from a series of samples taken in a short time period. The average value obtained from a sample is given as a result; additionally, the dispersion parameters are calculated which can be used to evaluate the probing process. This paper presents the research procedure which allows assessing the influence of chosen dispersion parameter related to the sample averaging on accuracy of the measurements performed with laser tracking devices. The procedure involves standard elements measurements during which the points with similar level of RMS parameter are used for the calculation of the measurement result. Such approach allows simulating the increasing dispersion of points taken into account during sample probing. The results presented in the article can be helpful to the operators of laser tracking systems to assess the influence of the probing process on the measurement accuracy.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 4; 94-99
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of the GPS receiver accuracy from the point of view of application in the multi-task machine for watercourses renovation
Badanie dokładności odbiornika GPS z punktu widzenia jego zastosowania w maszynie wielozadaniowej do renowacji rowów melioracyjnych
Autorzy:
Vicente, N.
Rutkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/335036.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
GPS
dokładność
renowacja
rów melioracyjny
watercourses
renovation
accuracy
Opis:
The accuracy results for the altitude positioning of SPAN-CPT GPS receiver, as well as its main characteristics, were described in the paper. The main goal of this research was to testify if the proposed GPS steering device and system is suitable for the positioning of the machine for renovation of opened watercourses.
W artykule opisano testy dokładności wskazań wysokości przez odbiornik GPS SPAN-CPT i przedstawiono wybrane wyniki. Głównym celem badań było potwierdzenie, że system jest odpowiedni do pozycjonowania maszyny do renowacji otwartych cieków wodnych.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2011, 56, 4; 178-183
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Qualitative analysis of the Novatel SPAN-CPT GPS receiver accuracy with and without the inertial measurement unit (IMU)
Porównawcza analiza dokładności odbiornika GPS Novatel SPAN-CPT z włączonym żyroskopem (IMU) i bez jego użycia
Autorzy:
Vicente, N.
Rutkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/335044.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
GPS
dokładność
żyroskop
analiza
analysis
inertial measurement unit
Opis:
The altitude measurements and the error information provided by the Novatel SPAN-CPT GPS receiver are reliable under good GPS signal reception, however, the adoption of this system in the machine for renovation of open water courses will be affected by the utilization or not of the Inertial Measurement Unit (IMU) during bad GPS signal conditions. Taking as reference the measurements performed under good GPS signal conditions, this paper compares the measurements obtained under bad GPS Signal conditions with and without IMU corrections.
Dokładny pomiar wysokości przez odbiornik GPS SPAN-CPT jest zapewniony przy dobrym sygnale GPS. W złych warunkach terenowych dokładność może być zwiększona przez wykorzystanie dodatkowej korekty, pochodzącej od jednostki żyroskopowej (IMU). W artykule porównano wyniki pomiarów dokładności pozycjonowania z włączonym żyroskopem i bez jego użycia.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2011, 56, 4; 184-188
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prosta metoda pomiaru prognozy zmian mesurandu w funkcji czasu
Simple Measurement Method for Forecast of Mesurand Variations
Autorzy:
Żuchowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/158130.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prognozy
metoda pomiaru
dokładność
forecasts
measurement method
accuracy
Opis:
Prognozowanie zmian pewnej wielkości fizykalnej w funkcji czasu może się odbywać z wykorzystaniem znajomości jej aktualnego stanu (pomiar) i znajomości ogólnych praw, lub reguł, którym te zmiany podlegają, albo wyłącznie na podstawie wyników pomiarów i określonych algorytmów prognozowania. Zaprezentowana zostanie metoda oparta o takie właśnie założenia, umożliwiająca praktycznie ciągły pomiar prognozy w przypadku sygnałów o stosunkowo gładkim przebiegu.
The forecast of variations of certain physical quantity can be done on the basis of its present state (result of measurement) and information on general rules describing possible state variations. Alternatively, one can design the forecast procedure using measurement results and dedicated algorithms for prediction. The paper presents the method using such alternative assumptions. Using this method one can obtain the continuous measurement of forecast for relatively smooth signals.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 8, 8; 717-720
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bankruptcy models : verifying their validity as a predictor of corporate failure
Modele upadłości : weryfikowanie ich ważności jako czynnik prognostyczny niepowodzenia korporacyjnego
Autorzy:
Kovacova, M.
Kliestik, T.
Kubala, P.
Valaskova, K.
Radišić, M.
Borocki, J.
Powiązania:
https://bibliotekanauki.pl/articles/406179.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
bankruptcy
company
prediction accuracy
upadłość
przedsiębiorstwo
dokładność przewidywania
Opis:
Although the issue of corporate failure analysis is a hot topic for business research since the last century, even nowadays there are numerous researches focusing on assessing the financial health of companies. Within increasing internationalization and globalization the demand for bankruptcy prediction is important not only for owners of the companies, but also for other interested groups. We aim to test the validity of prediction models developed as partial results of our research project. Bankruptcy prediction models were constructed on the data set of Slovak companies covering the year 2015 and based on the various statistical methodologies. We provided the validity of these models and their prediction accuracy on the data set of Slovak companies covering the following year 2016.
Chociaż kwestia analizy niepowodzenia korporacyjnego jest gorącym tematem badań biznesowych od zeszłego wieku, nawet obecnie prowadzone są liczne badania skupiające się na ocenie kondycji finansowej firm. W warunkach rosnącej internacjonalizacji i globalizacji zapotrzebowanie na prognozy bankructwa jest ważne nie tylko dla właścicieli firm, ale także dla innych zainteresowanych grup. Celem artykułu jest sprawdzenie ważności modeli prognostycznych opracowanych jako częściowe wyniki projektu badawczego przez autorów. Modele przewidywania bankructwa zostały zbudowane na zbiorze danych słowackich firm w roku 2015 na podstawie różnych metodologii statystycznych. Zapewniona została poprawność tych modeli i dokładność ich prognozowania na zbiorze danych słowackich firm obejmująca rok 2016.
Źródło:
Polish Journal of Management Studies; 2018, 18, 1; 167-179
2081-7452
Pojawia się w:
Polish Journal of Management Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miary dokładności transmitancji mostka rezystancyjnego w przypadkach szczególnych
Accuracy measures of transmittance of variable resistance bridge in particular cases
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/153528.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
dokładność
transmitancja
mostek rezystancyjny
accuracy
transmittance
resistance bridge
Opis:
Omówiono błędy chwilowe i graniczne oraz średniokwadratowe miary losowe (błędy pozorne lub niepewności) transmitancji prądowo-napięciowej w kilku przypadkach szczególnych czteroramiennego mostka rezystancyjnego jako czwórnika, tj.: przy różnych stosunkach wartości początkowych jego rezystancji i niezależnych oraz sprzężonych ich przyrostach w 4 lub 2 ramionach oraz przy zmiennym tylko jednym ramieniu. Wraz z odpowiednimi miarami transmitancji napięciowej zestawiono je w dwu tabelach. Wyznaczono też błędy napięcia wyjściowego mostka zasilanego prądowo.
Instantaneous and limited systematic errors and mean square measures (random errors or uncertainties) of current to voltage transmittance in some particular cases of the four arm resistance bridge as two-port, i.e.: for different ratios of initial arm resistances in balance, different number (4, 2 or 1) of independently variable and jointed their increments, are found and discussed. Together with corresponding measures of voltages transmittance they are presented in two tables. Errors of the open-circuit output voltage of this bridge supplied by current are also discussed.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 10, 10; 17-24
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza dokładności pozycjonowania w osiach liniowych centrum frezarskiego Hermle B300
The analysis of positioning accuracy along linear axes of the Hermle B300 milling center
Autorzy:
Miko, E.
Skrzyniarz, M.
Powiązania:
https://bibliotekanauki.pl/articles/154089.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
dokładność
pozycjonowanie
centrum frezarskie
accuracy
positioning
milling center
Opis:
Celem badań było określenie dokładności pozycjonowania w osiach liniowych centrum frezarskiego Hermle B300. Do badań zastosowano interferometr laserowy XL-80. Otrzymane wyniki porównano z wymaganiami dotyczącymi centrów obróbkowych przedstawionych w normie PN-ISO 10791-4, a także dokładnością zadeklarowaną przez producenta maszyny. Analiza uzyskanych wyników wykazała, że dokładność pozycjonowania w osi Z nie spełnia wszystkich wymagań określonych w normie.
The aim of the study was to evaluate the accuracy and repeatability of positioning along the linear axes of the Hermle B300 milling center. The tests were carried out with the use of an XL-80 laser interferometer. The first section of the paper shows how important it is to determine the positioning accuracy. There are also discussed the current international standards used to define methods of measurement and the relevant measuring equipment and its principle of operation. The next section describes the measuring methods applied in the analysis and the main assumptions concerning the measurement procedures. In the third section of the paper the results are analyzed. The results are presented graphically and in the form of a table. They are compared witch the requirements for the normal accuracy machining centers defined in the PN-ISO 10791-4 stand-ard. The results of the positioning accuracy are compared with the values declared by the manufacturer. The analysis of the results show that the accuracy of positioning for the Z-axis did not fulfill all the requirements defined in this norm.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 3, 3; 160-163
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zautomatyzowana korekcja błędów kątowej orientacji niemetrycznej kamery cyfrowej
Automated correction of angles orientation for nonmetric digital cameras
Autorzy:
Bernasik, J.
Mikrut, S.
Powiązania:
https://bibliotekanauki.pl/articles/131042.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
fotogrametria cyfrowa
kamery niemetryczne
orientacja kątowa
podpikselowa dokładność
Opis:
Autorzy podjęli prace prowadzące do stworzenia systemu pomiarowego, dzięki któremu - wykonując zdjęcia kamera cyfrowa zamocowana na teodolicie - można znać wszystkie elementy kątowej orientacji wiązki promieni tworzących obraz. Umożliwi to opisana w niniejszej pracy metoda zautomatyzowanej analizy dwóch „przeciwległych” zdjęć cyfrowych. Na podstawie takich zdjęć można – bez wykonywania pomiarów pola testowego – wyznaczyć poprawki do kątowych elementów orientacji kamery, aby następnie – w trybie „on line” – przeprowadzić transformacje przez obrót współrzędnych tłowych punktów zarejestrowanych cyfrowa kamera. Czynności analizy obrazów cyfrowych prowadzące do wyznaczenia omawianych poprawek zostały zautomatyzowane. Procedura ta stanowi pierwszy element opracowywanego systemu pomiarowego, mającego ułatwić rozwiązywanie rozmaitych inżynieryjnych zagadnień pomiarowych w czasie prawie rzeczywistym. Opisane prace prowadzone były pod katem wykorzystanie procedury korekcyjnej w przypadku pomiarów wychyleń od pionu wysmukłych budowli typu wieżowego (kominów przemysłowych, wie_, słupów itp.). Na podstawie 50 wyznaczonych wychyleń, porównanych z wychyleniami wyznaczonymi geodezyjnie, określono średni błąd pomiaru, który wyniósł: - w przypadku postępowania niezautomatyzowanego – ± 2,9 mm – co odpowiadało wartości 0,5 piksela. Porównanie tego błędu z pozostałymi (orientacji kamery i pomiaru w VSD) pozwala wnioskować, _e opisana procedura (wyznaczenia poprawek rektyfikacyjnych) wywarła na ostateczne wyniki wpływ zbliżony do wpływu pomiaru w VSD, - w przypadku postępowania zautomatyzowanego poniżej 0,5 piksela
The authors undertook works on the creation of a measurement system which, when taking photographs with the use of a digital camera fixed to a theodolite, allows to learn all elements of the angles orientation of the beam of rays that make up an image. This can be possible with the method of automated analyses of two "opposite" digital images, as presented herein. Based on such images, and without measuring the test field, one can determine corrections of angle elements of the camera's orientation, so that next, in the on-line mode, to perform transformation by means of rotating the coordinate background points, which were recorded by the digital camera. The operations of digital image analysis, which lead to the determination of said corrections, have been automated. That procedure constitutes the first element of the measurement system being developed which, in the opinion of its authors, should facilitate solving various engineering issues, related to measurements in an almost real time. The works under discussion were carried out from the point of view of utilization of the correction procedure in the case of measuring slender, tower-like structures that are out of plumb line (industrial stacks, towers, columns, etc.). Based on 50 deflections which were determined, compared with those determined by means of geodetic approach, average measurement errors were determined, amounting to the following values: - in the case of the non-automated procedure: ± 2.9 mm, which corresponded to the value of 0.5 pixels. By comparing that error with the remaining ones (those of the camera's orientation and those related to measurement performed with the use of VSD), it can be concluded that the procedure under discussion (determination of rectifying errors) effected the final results in the way similar to that of the VSD measurement - in the case of the automated procedure, the accuracy obtained was less than 0.5 pixels.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2007, 17a; 33-42
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
EGNOS - accuracy performance in Poland
Autorzy:
Mięsikowski, M.
Nowak, A.
Oszczak, B.
Specht, C.
Powiązania:
https://bibliotekanauki.pl/articles/320885.pdf
Data publikacji:
2006
Wydawca:
Polskie Forum Nawigacyjne
Tematy:
dokładność systemów nawigacyjnych
EGNOS
accuracy of navigation systems
Opis:
EGNOS - the first European satellite navigation system is a join project of the European Space Agency, Eurocontrol, European Commission and represents the fist step to towards Galileo - autonomous navigation satellite system of the 2nd generation (GNSS-2). The system Operational Readiness Review (ORR), took place in June 2005 and resumed of more than eight years of studies, works, leaded by ESA and an industrial consortium with Alcatel Space as the Prime Contractor. The Initial Operations Phase has therefore started in July 2005 as an effect of successful negotiations between ESA and European Satellite Services Provider. During the last years many different test, trials and measurement campaigns have been done in positioning, navigation, time services and other application for improving different characteristics of EGNOS [4, 5]. Some of them were also realised in Poland [1, 2] and observed accuracy confirm high system performances. Poland is at the edge of the system coverage then the system disturbances could be more probable than in the central part of the Europe. Presented paper reports final results of the, long-term static measuring campaigns, which were done before the EGNOS System Test Bed (ESTB) ending. Two-week accuracy analyses were done and the position error statistic distributions of system were also compared with the classical DGPS based on LF/MF reference station.
Źródło:
Annual of Navigation; 2006, 11; 63-72
1640-8632
Pojawia się w:
Annual of Navigation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiększanie dokładności wizyjnych metod kontroli jakości wytwarzania
Accuracy improvement of machine vision methods for manufacturing quality improvement
Autorzy:
Reiner, J.
Powiązania:
https://bibliotekanauki.pl/articles/269734.pdf
Data publikacji:
2010
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
dokładność wytwarzania
systemy wizyjne
precision manufacturing
vision system
Opis:
W artykule omówiono czynniki wpływające na dokładność pomiarów optycznych realizowanych za pomocą systemów wizyjnych. Zwrócono uwagę na wpływ jakości badanej powierzchni, wynikającej z wad ostrza narzędzia obróbkowego. Podkreślono znaczenie obiektywów telecentrycznych i oświetlenia skolimowanego dla minimalizacji nieprawidłowości detekcji krawędzi. Przedstawiono możliwości pomiarów charakterystyk elementów optycznych tj. ich dystorsję oraz funkcję przenoszenia modulacji MTF.
The paper discusses factors influencing the accuracy and precision of optical measurements realized by machine vision. The attention was turned to the quality of examined surface, resulting from defects on tool edge. The importance of telecentric lenses and collimated illumination for minimizing incorrect edge detection was stressed. The possibilities of optical elements characteristics measurement was presented e.g. distortion, and modulation transfer function MTF.
Źródło:
Inżynieria Maszyn; 2010, R. 15, z. 1/2; 80-89
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wymiarowa dokładność obróbki w przemyśle meblarskim
Razmernaja tochnost' obrabotki v mebel'nojj promyshlennosti
Dimensional processing accuracy in the furniture industry
Autorzy:
Kien, W.
Powiązania:
https://bibliotekanauki.pl/articles/798295.pdf
Data publikacji:
1990
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
dokladnosc
obrobka
przemysl meblowy
accuracy
treatment
furniture industry
Opis:
Точность обработки, особенно точность размерной обработки, приобретает в мебелестроительстве все большее значение. В исследованиях по этой проблеме проводимых Кафедрой деревообрабатывающих станков и промышленных устройств Сельскохозяйственной академии в Познани сосредоточивались на разработке системы толерантности и посадок, а также системы двухграничных шаблонов для большинства линейных размеров выступающих в мебельной промышленности. Система толерантности и посадок является предметом действительного в настоящее время отраслевого стандарта. Шаблоны характеризуются высокой степенью универсальности. Они производятся сериями. Основной выгодой применения системы толерантности и посадок, а также двухграничных шаблонов является возможность обеспечения полной заменимости частей и использования действительной точности современных деревообрабатывающих станков. Другие встречаемые все еще часто в деревообрабатывающей промышленности способы установки станков заключаются либо в использовании концево-штриховых мер, либо в использовании примитивных однограничных шаблонов. Оба указанные способа ввиду неминуемо сопутствующих им метрологических погрешностей характеризуются тем, что толерантность размеров получаемых в результате обработки гораздо шире действительной точности деревообрабатывающего станка. Система толерантности и посадки, а также двухгриничные шаблоны были внедрены в ряде мебельных заводов, а дальнейшие внедрительные работы в ходе проведения.
The accuracy of processing, particularly as concerns dimensions, becomes more and more important in the furniture industry. The investigations on this problem carried out by the Chair of Woodworking Machines and Industrial Appliances, Agricultural University of Poznań, were concentrated upon working out the tolerance and fitting system and the system of two-limit gauges for most linear dimensions occurring in the furniture industry. The tolerance and fitting system is taken into consideration in the valid branch standard. Gauges are characterized by a high universality degree. They are produced by series. The basic advantage connected with application of the tolerance and fitting system and of two-limit gauges consists in the possibility of ensuring a full exchangeability of details and use of the actual accuracy of the contemporary woodworking machines. Other setting ways of woodworking machines encountered still often in the wood processing industry consist either in the application of end-and-graduated rules (so-called meter rules), or in the use of primitive one-limit gauges. Both ways are characterized by the fact that, due to metrologie errors accompanying them unavoidably, the tolerance of dimensions obtained as a result of processing is much wider than the actual accuracy of the woodworking machine. The system of tolerance and fittings as well as two-limit gauges has been introduced in many furnituremaking plants, while further extension works are at the preperation stage.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 1990, 379
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność przybliżonej analizy drgań maszyn w stanach niestacjonarnych
Accuracy of machine vibrations approximated analysis in non-stationary states
Autorzy:
Krzyworzeka, P.
Cioch, W.
Jamro, E.
Powiązania:
https://bibliotekanauki.pl/articles/327508.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
diagnostyka
synchronizm
dokładność
decymacja
diagnostics
synchronism
accuracy
decimation
Opis:
Referat przedstawia wyniki zastosowania implementacji Procedury Liniowej Decymacji (PLD) zrealizowanej na Programowalnym Urządzeniu Diagnostycznym (PUD). Wykonane przez autorów urządzenie diagnostyczne miało na celu poszerzenie możliwości praktycznego wykorzystania metody. Zwiększenie nadpróbkowania do 10 MS/s i sprzętowa realizacja procedury PLD pozwoliły na wielokrotny wzrost współczynnika decymacji Dc (do 1000) oraz analizę sygnałów w pasmach wysokich częstotliwości (np. zazębienia). Wpływ dynamiki zmian cyklu referencyjnego na selektywność widmową przedstawiono w wynikach.
This paper presents practical implementation of Linear Decimation Procedure (LDP) employing the Programmable Unit for Diagnostic (PUD). The PUD device, designed and developed by the research authors, has extended abilities in order to improve the LDP results. Increased sampling rate (up to 10MS/s) and hardware implementation of the LDP allowed to increase decimation rate DC significantly (up to 1000) and to analyze signal frequency (e.g. gear mashing). Influence of dynamics of reference-cycle change on spectrum selectivity is showed in the experiment practical results.
Źródło:
Diagnostyka; 2006, 4(40); 203-208
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of the effectiveness of automatic targeting, using systems of ATR type, with manual targeting, based on full test procedure ISO 17123-3
Porównanie efektywności celowania automatycznego typu ATR oraz manualnego na podstawie pełnej procedury testowej ISO 17123-3
Autorzy:
Owerko, T.
Kuras, P.
Szafarczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/386080.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
automatyczne rozpoznanie celu
ISO
dokładność
automatic target recognition
accuracy
Opis:
The subject of the article is to compare the accuracy of targeting implemented in two manners – manual and automatic. The study was conducted based on international standard ISO 17123-3 for two theodolites equipped with the automatic target recognition system. The paper discusses surveying procedure – a full testing procedure, which allows to determine the actual accuracy of the tested instruments. The obtained values are the basis for conducting statistical tests that allow to verify the presented hypothesis.
Tematem artykułu jest porównanie dokładności celowania wykonywanego dwoma sposobami – manualnym i automatycznym. Badania przeprowadzono na podstawie międzynarodowej normy ISO 17123-3 dla dwóch teodolitów wyposażonych w system automatycznego rozpoznawania celu. W pracy omówiono procedurę pomiarową – pełną procedurę testową, która pozwala wyznaczać rzeczywiste dokładności badanych instrumentów. Uzyskane wartości stanowią podstawę do przeprowadzenia testów statystycznych, które pozwalają na zweryfikowanie stawianej hipotezy.
Źródło:
Geomatics and Environmental Engineering; 2010, 4, 1/1; 107-113
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określenie korekcji jonosferycznych EGNOS w eksperymencie lotniczym Dęblin (01.06.2010)
Designation the EGNOS ionospheric corrections in flight test in Dęblin (01.06.2010)
Autorzy:
Krasuski, K.
Jafernik, H.
Powiązania:
https://bibliotekanauki.pl/articles/316967.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
dokładność systemów nawigacyjnych
EGNOS
GPS
accuracy of navigation systems
Opis:
W artykule przedstawiono możliwości określenia opóźnienia jonosferycznego w programie SBAS MeNTOR 1.15. Wartość opóźnienia jonosferycznego została przedstawiona za pomocą parametrów VTEC oraz GIVE. Wartości parametrów VTEC i GIVE zostały określone na podstawie danych korekcyjnych od satelity EGNOS S120. Eksperyment badawczy został przeprowadzony na potrzeby implementacji techniki satelitarnej GNSS w nawigacji lotniczej.
Paper presents the possibility of designation the ionosphere delay in SBAS MeNTOR 1.15 software. The value of ionosphere delay was presented using VTEC and GIVE parameters. The values of VTEC and GIVE parameters were designated based on data corrections from EGNOS S120 satellite. The research test was conducted for purpose of implementation the GNSS satellite technique in air navigation.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 822-825, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność pomiaru RTN odbiornikiem Septentrio Altus Nr2
Accuracy of RTN measurement in various measurement conditions
Autorzy:
Oleniacz, G.
Skrzypczak, I.
Świętoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/372543.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
GPS
GLONASS
GNSS
Septentrio
system nawigacji satelitarnej
dokładność pomiaru
Opis:
Przeprowadzona seria testów odbiornika GNSS Septentrio Altus NR2 umożliwiła określenie rzeczywistych dokładności pomiaru RTN. Wielokrotnie powtarzane pomiary pozwoliły na oszacowanie dokładności w zależności od wykorzystanego systemu nawigacji satelitarnej (wyłącznie GPS oraz połączone GPS i GLONASS), czasu pomiaru na stanowisku oraz warunków panujących na stanowisku związanych z przesłonięciem horyzontu przez przeszkody terenowe (zarośla). Rezultaty badań wskazują na brak zależności pomiędzy zastosowaną technologią pomiaru a uzyskiwanymi dokładnościami oraz istotny wpływ warunków panujących na stanowisku na wyniki pomiarów.
Series of GNSS receiver tests allowed to determine real accuracy of RTN measurements. Repeated measurements allowed to estimate accuracy in function of used navigation satellite system, duration of measurements and field conditions on measurement site which are related to horizon visibility by obstacles (bushes). Research results indicate no dependency between the technology used and the measurement accuracies obtained and significant impact of the conditions on set-up on the measurement's results.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2017, 166 (46); 16-24
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomaganie decyzji z wykorzystaniem narzędzi GIS – ryzyko związane z dokładnością danych źródłowych
GIS – a tool in decision support – risk caused by data quality effect
Autorzy:
Hejmanowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/129894.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
GIS
dokładność danych
wspomaganie decyzji
data accuracy
decision support
Opis:
Systemy GIS oferują bogate narzędzia analityczne do przetwarzania danych, które również w Polsce stopniowo zaczynają być wykorzystywane do wspomagania decyzji. Pojawia się w związku z tym pytanie: jakie jest ryzyko związane z decyzją podjętą na podstawie analiz GIS? Na ryzyko podjęcia nieprawidłowej decyzji ma wpływ na pewno jakość danych źródłowych znajdujących się w bazie. Zwykle jednak nie tylko dane są podstawą podjęcia decyzji, ale wyniki ich przetworzeń. Dane źródłowe podlegają przekształceniom, są wykorzystywane jako dane wejściowe w różnych modelach. Wynik analizy jest obciążony zarówno niedokładnością danych źródłowych, jak również niedokładnością wykorzystywanych algorytmów i nieadekwatnością modeli do rzeczywistości. W systemach GIS, tworzonych w Polsce, rzadko gromadzi się informacje o dokładności danych źródłowych. Z kolei wykorzystywane oprogramowanie GIS tylko sporadycznie umożliwia analizę wpływu dokładności danych na wynik przeprowadzonej analizy. Problem ten jest pozostawiony do rozwiązania indywidualnemu użytkownikowi. W niektórych narzędziach GIS ma on do wyboru najbardziej, popularną obecnie, metodę Monte Carlo. Metoda ta, pomimo, że jest uniwersalna, tzn. może być wykorzystywana właściwie we wszystkich analizach GIS, ma dwie wady: analizy trzeba wykonywać setki razy, żeby oszacować dokładność wyniku analizy, a poza tym nie pozwala ona na określanie przestrzennego rozkładu dokładności analizy. Alternatywą są metody analityczne lub empiryczne, o ile znane są wykorzystywane w systemie GIS algorytmy obliczeniowe. Przedstawiona powyżej problematyka, dotycząca wpływu dokładności danych na ryzyko podejmowania decyzji z wykorzystaniem systemów GIS, została omówiona szerzej w niniejszej publikacji. Porównano w niej wyniki analizy przestrzennych wykonanej z uwzględnieniem wpływu dokładności danych źródłowych oraz bez uwzględnienia tego faktu. Problem przenoszenia się dokładności danych źródłowych na wynik analizy przestrzennej pokazano na przykładzie wyboru nowej lokalizacji pod zabudowę. W analizie uwzględniono dokładność numerycznego modelu terenu (DTM). Umożliwiło to oszacowanie ryzyka związanego z podjęciem decyzji wyboru lokalizacji i koniecznością wykonania nieplanowanych prac ziemnych w celu wyrównaniem terenu.
There are many GIS tools for data analysis, also applied in Poland to decision support. The following question can appear: what is the risk of a decision based on the GIS analysis? GIS data quality certainly affects on the decision risk. Usually not only raw data are analyzed, but also the results of data transformations. Data are often transformed in GIS systems and used in different models as input data. Results of transformation are influenced by the original data quality (especially accuracy) and model/algorithm reliability. In GIS databases in Poland, information on data quality is very rare gathered. On the other hand, GIS software only occasionally delivers tools for algorithm and function accuracy analysis. The problem is left individually to the user. In some software, the popular Monte Carlo method is implemented. The method is very universal, it means that can be applied in almost all GIS analyses Monte Carlo has also disadvantages: analyses must be carried out hundreds times, and the spatial distribution of the results error is difficult to obtain. Analytical or empirical methods are an alternative if the algorithms implemented in GIS software are known. In the paper, the risk connected to the GIS analyses based on the data with known accuracy is presented. Spatial analysis is performed by hard methods, without data quality consideration and assuming some data uncertainty. Error propagation is presented in the paper based on a new urban area example and the DTM accuracy was considered in the spatial analysis. The risk of ground leveling caused by DTM inaccuracy was evaluated.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 197-206
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ kalibracji anten odbiorników GNSS na dokładność pomiarów statycznych
GNSS antennas callibration in static surveying accuracy
Autorzy:
Szeptalin, A.
Powiązania:
https://bibliotekanauki.pl/articles/60798.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
urzadzenia pomiarowe
odbiornik GNSS
kalibracja
pomiary statyczne
dokladnosc pomiaru
Opis:
Geodezyjne urządzenia pomiarowe takie jak tachimetry i niwelatory poddawane są kontroli i w razie potrzeby – kalibracji. Takie same procedury powinny dotyczył urządzeń do pomiarów w technologii GNSS (Global Navigational Satellite System – Globalny System Nawigacji Satelitarnej). Badanie zbliżone do kalibracji względnej wykonane na dwóch antenach GNSS tego samego modelu (Trimble 5800) wykazało, że anteny różnią się od siebie a wpływ poprawek kalibracyjnych na obie anteny jest różny. Może to oznaczać konieczność stosowania indywidualnych plików kalibracyjnych przygotowanych specjalnie dla konkretnej anteny. Dzięki kalibracji anten oraz dbałości o odpowiednie ich zorientowanie podczas pomiaru możliwe jest poprawienie dokładności pomiarów statycznych GNSS.
Surveying devices like tachymeters and levels might be monitored and if it is necessary – calibrated. Similar procedures should apply to GNSS (Global Navigational Satellite System) measuring sets. The semi-calibrating research on two GNSS antennas (Trimble 5800) shows that antennas are different and the calibration files have different influence on both. it means that probably individual calibrations files are needed. Antenna calibration and correct orientation of antenna during the GNSS survey may lead to better positions’ accuracies.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2012, 1/III
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization CSRS-PPP software for recovery aircraft’s position
Autorzy:
Krasuski, K.
Powiązania:
https://bibliotekanauki.pl/articles/197503.pdf
Data publikacji:
2015
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
GPS
PPP method
positioning accuracy
metoda PPP
dokładność pozycjonowania
Opis:
The PPP method is applied in aeronautical navigation as a new technique for determination of aircraft’s position. In this paper preliminary results of recovery aircraft’s position were presented. The raw GPS observations from Topcon dual-frequency receiver were utilized to position obtained with temporal resolution 1 second. Service on-line CSRS-PPP was used for estimation vehicle coordinates and receiver clock, troposphere delay and ambiguity term also. Preliminary results of aircraft’s position show that accuracy of horizontal coordinates is about 3 cm and less than 7 cm for vertical coordinate, respectively. The high level accuracy of coordinates is assured by using precise products such as GPS ephemeris and clocks.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2015, 89; 61-68
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania błędu współczynnika wzmocnienia wzmacniaczy z rezystancyjnym dynamicznym sprzężeniem zwrotnym
Research of the gain error of amplifiers with resistor dynamic-feedback
Autorzy:
Dorozhovets, M.
Powiązania:
https://bibliotekanauki.pl/articles/155893.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
dokładność
wzmacniacz
sprzężenie zwrotne
dynamiczne
accuracy
amplifier
dynamic
feedback
Opis:
The analysis results of the amplification factor relative error of three kinds of amplifiers (non-inverting (Fig. 1,b), inverting (Fig. 2,a) and differential (Fig. 2,b)) based on resistors dynamic-feedback are presented in the paper. Such amplifiers are used for signal amplification in a wide dynamic range when, practically, the same value of the relative error of different amplification factors is required. It is shown that values of the mean and standard deviation of the mean amplification factor relative errors are proportional to the square of the resistance relative standard deviation: formulas (7), (8), (10). Moreover, it is shown that the mean error value do not practically depended on the number of used resistors. The error standard deviation decreases proportionally to the root square of the number of resistors. The characteristics of the amplification factor relative errors calculated by analytical formulas and by the Monte Carlo method for different number of feed-back resistors (from 2 to 100) are shown in Fig. 3. Based on the analysis of the influence of switch variation resistance on the amplification factor error, the condition (13) for correct choice of switches is obtained. It is shown that using resistors with the relative standard deviation of 0,1% and switches whose resistance deviation corresponds to the condition (13), it is possible to obtain the amplification factor accuracy of a few ppm.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 12, 12; 1053-1056
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie dokładności pozycjonowania i diagnostyka tokarki CNC
The positioning accuracy and diagnosis of CNC machine tools
Autorzy:
Miko, E.
Maj, P.
Powiązania:
https://bibliotekanauki.pl/articles/156194.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tokarka
dokładność
pozycjonowanie
diagnostyka
CNC
lathe
precision
positioning
diagnostics
Opis:
Celem badań było przeprowadzenie pomiarów dokładności pozycjonowania i diagnostyki tokarki sterowanej numerycznie CTX 410 Gildemeister. Do pomiarów dokładności pozycjonowania wykorzystano Interferometr Laserowy XL-80, a do diagnostyki „Szybki Test” Ballbar QC-10. Analiza uzyskanych pomiarów wykazała, że wartości mierzone nie mieściły się w tolerancji wartości dopuszczalnych dla tej obrabiarki.
The aim of the research was to make measurements and diagnostics positioning of a numerically controlled lathe-Gildemeister CTX 410. An interferometr laser XL-80 was used for measurements of the positioning accuracy. The roundness test and diagnostics were carried out using "Quick Test" Ballbar. The first section of the paper lists the reasons for inaccuracies of machines and why they are so important. There is the basic information about the testing equipment which enable their measurements. In the next section the equipment is described in details. There is also described the method of installation and testing process. For each type of measurement the equipment configuration was different. It was determined by the workspace and machine capabilities. Section 3 contains some results of investigations. The analysis of the measurements shows that the measured values do not fit in the tolerance limits for this machine.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 6, 6; 558-561
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Example of the assessment of data integration accuracy on the base of airborne and terrestrial laser scanning
Autorzy:
Warchoł, A.
Hejmanowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/130165.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
lidar
TLS
accuracy
analysis
integration
LIDAR
dokładność
analiza
integracja
Opis:
Light detection and ranging (LiDAR) technology has changed conventional approach to the spatial data acquisition. Unusually amount of the measurements points with extremely high precision are now available from generally two platforms: airborne (Airborne Laser Scanner - ALS) and terrestrial (Terrestrial Laser Scanner - TLS). There are however some gaps in these products, in ALS - on vertical surfaces and in TLS - on horizontal one. The reason is that these laser systems register the same object from different points in space. Integration of the data obtained for airborne and terrestrial platforms can fulfil the gaps. The aim of the research presented in the paper was comparing the matched ALS and TLS data to the in-situ total station (TS) measurements. Different test areas were chosen: placed on horizontal, vertical or inclined surfaces and covered by grass or asphalt pavement. Point’s positions obtained from ALS, TLS and TS measurements are analysed together. TS measurements are taken as a reference. ALS and TLS point position accuracy analysis based on these perpendicular distance from the plane defined by the nearest three non-collinear TS points. The discrepancies were further statistically analysed. In conclusion can be stated that some bias was observed in ALS data, they are below TLS and TS points as well. Besides more significant discrepancy between TS points are observed for ALS points in compare to the TLS one, confirming our expectations.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2011, 22; 411-421
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ gatunku ścierniwa na dokładność wałków stalowych po szlifowaniu ściernicowym
Effect of grinding wheels grade on the machining accuracy after grinding steel rollers
Autorzy:
Niżankowski, C.
Matras, A.
Powiązania:
https://bibliotekanauki.pl/articles/269740.pdf
Data publikacji:
2010
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
ścierniwo
szlifowanie ściernicowe
dokładność obróbki
abrasive
grinding
precision machining
Opis:
Wskazano przesłanki uzasadniające podjęcie tematu pracy. Określono charakter i obszar badań oraz kryteria oceny wpływu gatunku ścierniwa na dokładność wałków stalowych po szlifowaniu ściernicowym. Przedstawiono wyniki porównawczych badań doświadczalnych chropowatości, falistości i dokładności kształtu powierzchni wałków po osiowym, obwodowym szlifowaniu klasycznymi ściernicami elektrokorundowymi i ściernicami nowej generacji zawierającymi ścierniwo korundowe gatunku TGP.
The reasons of the work theme have been pointed up. The nature and area of study and criteria for assessment of the impact of grinding wheels grade on the grinding accuracy have been defined. The results of comparative experimental studies of surface roughness, waviness and shape error after axial grinding, which compared a corundum and new generation TGP corundum grade have been presented and discussed.
Źródło:
Inżynieria Maszyn; 2010, R. 15, z. 3; 55-68
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładnie, czyli jak?
Accurately, which is how?
Autorzy:
Gadomska, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/952618.pdf
Data publikacji:
2018
Wydawca:
Główny Urząd Miar
Tematy:
metrologia
terminologia
dokładność pomiaru
metrology
terminology
accuracy of measurement
Opis:
Od 100 lat oficjalnie w Polsce mierzymy i ważymy, i robimy to z coraz większą dokładnością. Jednak ten, jakże ważny metrologiczny termin, jest niezwykle często przedstawiany w zupełnie niewłaściwym znaczeniu. Pożądana przez wszystkich metrologów jednolitość, to również jednolicie rozumiana terminologia. Niestety w zakresie „dokładności” sytuacja jest więcej niż niejednoznaczna. Artykuł przedstawia słownikową definicję tego terminu, jego interpretację oraz zawiera przykłady jego niewłaściwego użycia. Wskazuje możliwe kierunki działań służących poprawie terminologicznych niejednoznaczności.
We have been officially measuring and weighing in Poland for 100 years, and we are doing it with increasing accuracy. However, this important metrological term is enormously often presented in a completely wrong meaning. The uniformity desired by all metrologists is also a uniformly understood terminology. Unfortunately, in terms of "accuracy” the situation is more than ambiguous. This article presents a vocabulary definition of this term, its interpretation and contains examples of its misuse. The article summary indicates possible directions of actions to improve terminological ambiguities.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2018, 2 (21); 57-60
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność rozdrabniania liści mięty pieprzowej
Accuracy of grinding of peppermint leaves
Autorzy:
Flizikowski, J.
Taranowska, U.
Powiązania:
https://bibliotekanauki.pl/articles/2073134.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rozdrabnianie ziół
dokładność pomiaru
grinding of herbs
measurement accuracy
Opis:
Sprawdzono możliwości realizacji nowego procesu i określono dokładności wybranych charakterystyk rozdrabniania mięty pieprzowej. Rozdrabnianie przeprowadzono w rozdrabniaczu wielotarczowym produkcji ZBPP w Bydgoszczy. Gromadzenie, analizę i przetwarzanie danych na wskaźniki stanów zrealizowano w środowisku oprogramowania LabVIEW.
The feasibility of new process and determination of accuracy of selected grinding characteristics of peppermint were checked. The shredding was performed in the disengaged chipper made by ZBPP in Bydgoszcz. The collection, analysis and processing of data into state indicators were performed in the LabVIEW software environment.
Źródło:
Inżynieria i Aparatura Chemiczna; 2016, 4; 132--133
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy analysis of aircraft positioning using GPS dual receivers in aerial navigation
Autorzy:
Krasuski, Kamil
Ciećko, Adam
Wierzbicki, Damian
Powiązania:
https://bibliotekanauki.pl/articles/2173448.pdf
Data publikacji:
2022
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
GPS
accuracy
receiver
position errors
dokładność
odbiornik
błędy położenia
Opis:
. This study presents a modified algorithm to determine the accuracy of GPS positioning in aerial navigation. To achieve this, a mixed model with measurement weights was used to determine the resultant value of accuracy of aerial vehicle positioning. The measurement weights were calculated as a function of the number of GPS tracking satellites. The calculations were performed on actual GPS measurement data recorded by two onboard GNSS receivers installed onboard a Cessna 172 aircraft. The flight test was conducted around the military airport in Dęblin. The conducted analyses demonstrated that the developed algorithm improved the accuracy of GPS positioning from 62 to 91% for horizontal coordinates and between 16-83% for the vertical component of the aerial vehicle position in the BLh ellipsoidal frame. The obtained test results show that the developed method improves the accuracy of aircraft position and could be applied in aerial navigation.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2022, 115; 23--34
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyka oceny dokładności i scalania wieloźródłowych numerycznych modeli teren
Methodology of accuracy assessment and merging of multisource digital terrain model
Autorzy:
Kurczyński, Z.
Powiązania:
https://bibliotekanauki.pl/articles/130676.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
NMT
ocena dokładności
scalanie NMT
dokładność bezwzględna
dokładność względna
model różnicowy
histogram
DTM
accuracy assessment
DTM merging
absolute accuracy
relative accuracy
differential model
Opis:
Kraj pokryty jest danymi wysokościowymi w kilku standardach. Pojawiają się nowe produkty, o lepszych parametrach. Użytkownik coraz częściej staje wobec problemu oceny dokładności wieloźródłowych produktów i ich scalenia na interesującym obszarze. W pracy podaje się charakterystykę głównych typów NMT występujących na obszarze kraju. W dalszej kolejności dyskutowana jest metodyka oceny dokładności wysokościowej NMT. W zagadnieniu łączenia dwóch modeli podjęto problem „płynnego” przejścia wysokości na granicy łączenia. W części eksperymentalnej poddano ocenie dokładności cztery różne NMT występujące na tym samym obszarze. Produkty były oceniane na profilach kontrolnych oraz powierzchniowo, poprzez generowanie różnicowych modeli. Wykorzystano zaproponowane wcześniej wskaźniki oceny dokładności. Eksperyment pokazał, że jakość NMT LPIS i DTED-2 jest lepsza niż to się powszechnie przyjmuje. Dane SRTM są obarczone znacznym, ale stałym błędem. Po usunięciu składnika systematycznego, dla terenów odkrytych, można uzyskać dokładność na poziomie 1 m, co jest zaskakująco dobrym wynikiem. W pracach eksperymentalnych wykazano wysoką użyteczność oprogramowania SCOP++ do generowania, oceny dokładności i łączenia różnych NMT.
W pracach eksperymentalnych wykazano wysoką użyteczność oprogramowania SCOP++ do generowania, oceny dokładności i łączenia różnych NMT. The surface of Poland is visualized by height data collected and presented according to several standards. DTMs that are available for various areas are constantly improved by application of new products which feature better parameters. Consequently, a “mosaic” of various data emerges; it is expected that the differentiation will increase with time. As a result, the user is increasingly frequently faced with a problem of assessing the accuracy of multisource products and their merging for an area of interest. The paper provides a characteristics of the major DTM types applied to the same areas in Poland. The methodology of the DTM accuracy assessment is discussed in detail. Random and systematic errors are distinguished and the consistently absolute and relative accuracies are assessed. The paper points out to the lack of homogenous, standardized DTM quality indices. Often, the grid size is assumed to be such an index, which may lead to confusion and misunderstanding. Relationships between the grid size, height accuracy, and the form of the terrain are presented and technological relations between those parameters are described. In the context of merging two different DTMs, the problem of a “smooth” passage of the height at the boundary between them is discussed. The experimental part of the paper deals with the accuracy of four different DTMs covering the same area: a DTM obtained within the Flood Recovery Project, a DTM arrived at within the LPIS project (DTM LPIS), a DTM in the DTED-2 format, and a DTM resulting from the SRTM mission. The products (DTMs) were evaluated – by generation of differential models - with respect to terrain profiles and the area covered. The DTM quality indices, proposed earlier, were used. The experiment showed the quality of DTM LPIS and DTED-2 to be better than usually assumed. The SRTM data are burdened with a considerable, but constant, error of 3.3 m. The afforest areas showed a consistent effect of tree height. Those data belong to the digital surface model (DSM) rather than to the DTM category. After removal of the systematic component, the accuracy on the order of 1 m, a surprisingly good result, is obtained. The experimental part showed a high utility of the SCOP++ software in the generation, accuracy assessment, and merging of various DTMs.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2008, 18a; 343-353
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność globalnych map użytkowania ziemi i pokrycia terenu na przykładzie Global Land Cover Characterization Data Base
Accuracy of global land cover datasets: example of Global Land Cover Characterization Data Base
Autorzy:
Kozak, J.
Powiązania:
https://bibliotekanauki.pl/articles/130213.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
dane globalne
lasy
Europa
dokładność
global data
forests
Europe
accuracy
Opis:
W badaniach oceniono dokładność wyznaczenia powierzchni europejskich lasów w bazie danych Global Land Cover Characterization (GLCC). Jako dane referencyjne wykorzystana została mapa CORINE Major Land Cover Types of Europe. Dla danych zagregowanych do dwóch klas: lasy i obszary nieleśne obliczono wskaźniki dokładności. Przestrzenne zróżnicowanie dokładności badano w polach podstawowych 100 × 100 km. Powierzchnie lasów w obu bazach danych są zbliżone, co wynika z kompensowania się błędów niedoszacowania i przeszacowania powierzchni leśnej w bazie danych GLCC. Lesistość szacowana za pomocą GLCC może znacząco różnić się od wartości faktycznych. Przeszacowanie powierzchni leśnej cechuje Skandynawię, niedoszacowanie niziny zachodniej i środkowej Europy. Współczynnik Kappa zmienia się od 0 do 70%. Wartości wskaźników dokładności są zależne od faktycznej lesistości. Błędy w oszacowaniu powierzchni leśnej danych GLCC wynikają przede wszystkim z wykorzystania danych wejściowych o małej rozdzielczości przestrzennej dla obszarów o znacznej heterogeniczności użytkowania ziemi i pokrycia terenu. Błędy te mogą być korygowane za pomocą prostych technik kalibracyjnych.
The study attempts to estimate the accuracy of the delimitation of European forests within the Global Land Cover Characterization (GLCC) Data Base. As a reference, CORINE Major Land Cover Types of Europe data set was used. The analysis was carried out for data aggregated to two classes: forests and non-forest areas. Matrix overlays allowed computation of accuracy indices. Kappa coefficient and the difference of actual (CORINE) and predicted (GLCC) forest proportion were mapped for spatial units 100 × 100 km. The area of forests derived from the CORINE data equals 1.18•106 km2, and the value predicted is almost exactly the same, 1.17•106 km2. User’s and producer’s accuracies of forest delimitation equal 57%. Local differences between actual and predicted forest proportion may exceed 25 percentage points. Overestimation of the forest area occurs in Scandinavia, while underestimation in lowland Western and Central Europe. Kappa coefficient varies from 0 up to almost 70%. Low values were found in lowland Central and Western Europe, Ireland, the Mediterranean and Scandinavia. Values exceeding 40% were observed in a belt stretching from northern Spain to Bulgaria. Differences between actual and predicted forest proportion, as well as Kappa coefficient depend on the actual forest proportion. Errors of forest delimitation within the GLCC data set are related mainly to the classification of coarse resolution data in areas of highly diverse land cover pattern. The overestimation of dominant land cover classes in the GLCC leads to locally inaccurate predictions, which should be calibrated for the purposes of regional research.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2003, 13a; 97-107
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stochastic modelling and analysis of IMU sensor errors
Autorzy:
Zhao, Y.
Horemuz, M.
Sjöberg, L. E.
Powiązania:
https://bibliotekanauki.pl/articles/130312.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
IMU
integration
accuracy
navigation
sensor
random
integracja
dokładność
nawigacja
czujnik
Opis:
The performance of a GPS/INS integration system is greatly determined by the ability of stand-alone INS system to determine position and attitude within GPS outage. The positional and attitude precision degrades rapidly during GPS outage due to INS sensor errors. With advantages of low price and volume, the Micro Electrical Mechanical Sensors (MEMS) have been wildly used in GPS/INS integration. Moreover, standalone MEMS can keep a reasonable positional precision only a few seconds due to systematic and random sensor errors. General stochastic error sources existing in inertial sensors can be modelled as (IEEE STD 647, 2006) Quantization Noise, Random Walk, Bias Instability, Rate Random Walk and Rate Ramp. Here we apply different methods to analyze the stochastic sensor errors, i.e. autoregressive modelling, Gauss-Markov process, Power Spectral Density and Allan Variance. Then the tests on a MEMS based inertial measurement unit were carried out with these methods. The results show that different methods give similar estimates of stochastic error model parameters. These values can be used further in the Kalman filter for better navigation accuracy and in the Doppler frequency estimate for faster acquisition after GPS signal outage.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2011, 22; 437-449
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność procesu dozowania na przykładzie linii do rozlewu kefiru
Proportioning process accuracy on the example of kefir filling line
Autorzy:
Kusińska, E.
Powiązania:
https://bibliotekanauki.pl/articles/291356.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
przemysł mleczarski
kefir
dozowanie
dokładność dozowania
milk industry
proportioning
accuracy
Opis:
W pracy przedstawiono wyniki dokładności dozowania automatu rozlewniczo-pakującego stosowanego w przemyśle mleczarskim podczas pakowania kefiru i ocenę przydatności danej partii towaru przed wprowadzeniem na rynek. Pierwsza część badań dotyczyła oceny partii produktu przed wprowadzeniem w zakładzie systemu kontroli, a druga część badań polegała na ocenie partii na podstawie wprowadzonego wewnętrznego systemu kontroli masy netto i objętości towaru paczkowanego w opakowaniu. W wyniku wprowadzenia wewnętrznego systemu kontroli towarów paczkowanych poprawiła się dokładność dozowania towaru.
The paper presents the results of tests on proportioning accuracy of automatic machine for filling and packing used in milk industry for kefir packaging, and the assessment of usability for a given batch before launching it into the market. The first part of tests concerned product batch assessment before launching at control system plant, and the second one involved batch assessment on the basis of the introduced internal control system for net mass and volume of packaged goods in a package. The introducing of internal control system for packaged goods contributed to a more accurate proportioning.
Źródło:
Inżynieria Rolnicza; 2009, R. 13, nr 5, 5; 139-146
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza dokładności wskazań obiektów nawodnych
Accuracy Analysis of Sea Objects
Autorzy:
Burzyński, A.
Powiązania:
https://bibliotekanauki.pl/articles/360517.pdf
Data publikacji:
2006
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
dokładność
radar
obiekty nawodne
EXPLO-SHIP 2006
accuracy
sea objects
Opis:
W artykule analizowano dokładności wskazań obiektów znajdujących się na wodzie. Badania wybranych obiektów prowadzono wykorzystując zespół radarów Centrum VTS Zatoka Gdańska i porównywano je z rzeczywistymi pozycjami odczytanymi za pomocą DGPS.
In his article the author analyses the accuracy of objects which are situated on the sea. Research on selected objects has been carried out in the Vessel Traffic Service covering the Gulf of Gdansk. The author compares positions of those objects on the basis of VTS and DGPS readings.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2006, 11 (83); 29-38
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania docierania powierzchni płasko-równoległych na docierarkach
Study of lapping surfaces on two-disk lapping machine
Autorzy:
Barylski, A.
Powiązania:
https://bibliotekanauki.pl/articles/269449.pdf
Data publikacji:
2013
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
docieranie
układ kinematyczny
dokładność
kształt
lapping
kinematic system
shape
exactness
Opis:
Zamieszczono wyniki badań powierzchni docieranych na docierarkach dwutarczowych o obiegowym układzie kinematycznym. Określono wpływ nacisku jednostkowego i czasu obróbki na jakość powierzchni w aspekcie współzależności dokładności kształtu powierzchni czynnych tarcz docierających i powierzchni obrabianych.
This paper contains experimental results of surface lapped by double-plate lapping machine with eiroular drive. The influence of unit pressure and machining time on processing quality is determined regarding interdependence of shape exactness of active surfaces of laps and lapped surfaces.
Źródło:
Inżynieria Maszyn; 2013, R. 18, z. 2; 76-83
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy and precision of RTK positioning under forest conditions
Autorzy:
Pelc-Mieczkowska, R.
Bakuła, M.
Powiązania:
https://bibliotekanauki.pl/articles/224466.pdf
Data publikacji:
2011
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
RTK positioning
measurement accuracy
forest
pozycjonowanie RTK
dokładność pomiarów
las
Opis:
The paper discusses the issue of relation between the accuracy and precision of GNSS/RTK measurements conducted at points with limited visibility of satellites. Field experiments were conducted from 2005 until 2010 on forest points characterised with different intensities of obstructions. The results of measurements obtained showed, which is characteristic for forest conditions, high precision but the accuracy of the results obtained ranged from under a centimetre to even a few metres. The analyses presented in this paper show that obtaining accurate coordinates from RTK positioning under forest conditions is possible but a method to eliminate gross errors must be developed.
Źródło:
Reports on Geodesy; 2011, z. 1/90; 377-382
0867-3179
Pojawia się w:
Reports on Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel single-step procedure for the calibration of the mounting parameters of a multi-camera terrestrial mobile mapping system
Autorzy:
Habib, A.
Kersting, A.
Bang, K.
Rau, J.
Powiązania:
https://bibliotekanauki.pl/articles/129833.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
photogrammetry
calibration
mobile
system
multisensor
accuracy
fotogrametria
kalibracja
mobilny
dokładność
Opis:
Mobile Mapping Systems (MMS) can be defined as moving platforms which integrates a set of imaging sensors and a position and orientation system (POS) for the collection of geo spatial information. In order to fully explore the potential accuracy of such systems and guarantee accurate multi-sensor integration, a careful system calibration must be carried out. System calibration involves individual sensor calibration as well as the estimation of the inter-sensor geometric relationship. This paper tackles a specific component of the system calibration process of a multi-camera MMS – the estimation of the relative orientation parameters among the cameras, i.e., the inter-camera geometric relationship (lever-arm offsets and boresight angles among the cameras). For that purpose, a novel single step procedure, which is easy to implement and not computationally intensive, will be introduced. The proposed method is implemented in such a way that it can also be used for the estimation of the mounting parameters among the cameras and the IMU body frame, in case of directly georeferenced systems. The performance of the proposed method is evaluated through experimental results using simulated data. A comparative analysis between the proposed single-step and the two-step, which makes use of the traditional bundle adjustment procedure, is demonstrated.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2011, 22; 173-185
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności pomiarów w mikrotechnologiach materiałowych
Estimation of measurement accuracy in materials microtechnologies
Autorzy:
Pawlak, R.
Klimek, L.
Kawczyński, R.
Tomczyk, M.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/158244.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
dokładność pomiarów
laserowe mikrotechnologie materiałowe
measurements accuracy
materials laser microtechnologies
Opis:
Pomiar różnorodnych wielkości fizycznych, określających cechy materiałowe elementów, podlegających obróbce przestrzennej lub modyfikacji w wyniku oddziaływania wiązki laserowej jest trudny ze względu na mikroskopijne wymiary elementów finalnych. W artykule omówiono wybrane zagadnienia dokładności pomiarów w trakcie opracowywania nowej technologii w skali mikrometrowej (pomiary parametrów wiązki laserowej, określania właściwości strukturalnych i mikrotwardości jako wybranej cechy funkcjonalnej).
Majority of material technologies making use of a laser beam are micro-technologies in micrometer- or even nanoscale. Such technological processes, considering that the volume of materials undergoing modification or synthesis as a result of laser treatment is extreme small, are very difficult to control in real time ("on line"). Therefore, proper elaboration of the microtechnology in order to prevent a measurement of large number of parameters during its multiple reproduction is the task of great importance. Direct use of measuring methods for macroscopic material objects is not acceptable. Generally, there are not many sophisticated measuring methods and systems for micro- or nanoscale. Problems of measurement accuracy are discussed in the paper. The authors tried to solve them during their research at different stages of new laser microtechnologies. The presented issues include measurements of selected laser beam parameters, structural evaluation, among other, electron microanalysis and some functional properties of elements produced by laser technology.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 10, 10; 1213-1216
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ przewodu nasiennego w siewniku precyzyjnym MG-6 na dokładność rozmieszczenia nasion w siewie punktowym
Vlijanie semjaprovoda na tochnost razmeshhenija semjan v punktirnom poseve
Effect of the seed pipe form on the accuracy of seed distribution in the single-seed sowing
Autorzy:
Walczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/795995.pdf
Data publikacji:
1989
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
przewody nasienne
siewniki precyzyjne
MG-6
dokladnosc
rozmieszczenie
wysiew nasion
Opis:
Проводились испытания работы точной ленточной сеялки МГ-6 японского производства с особым учетом влияния семяпровода на размещение семян в рядку. Это размещение определяли с помощью посева на липкую ленту с электронным измерением расстояний между семенами.Для анализа пути полета семян использовали фильмово-стробоскопную технику. Установлено, чтоо даже слишком короткий семяпровод примененный в испытуемой сеялке приводит к ухудшению точности размещения семян в рядку.
Work of the precise conveyor drill MG-6 of the Japanese make was tested, at a particular consideration of the seed pipe form effect on distribution of seeds in a row. This distribution was determined by means of sowing seeds onto viscous tape at electronic measurement of spacings. The analysis of seed flight paths was periormed at application of the film-stroboscopic technique. It has been found that a short seed pipe applied in the drill tested results in a worse distribution of seeds in a row.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 1989, 365
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania dokładności ręcznych odbiorników GPS
Researching the accuracy of hand held GPS receivers
Autorzy:
Plewako, M.
Powiązania:
https://bibliotekanauki.pl/articles/61695.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
pomiary GPS
dokladnosc pomiaru
odbiorniki GPS
bledy pomiarowe
bledy systematyczne
Opis:
Analizując wyniki wyznaczania współrzędnych x, y, pojedynczego punktu ręcznym odbiornikiem GPS, można stwierdzić występowanie składnika systematycznego. Okoliczność ta występuje dla różnych typów odbiorników, w różnych miejscach kraju, dla różnych układów odniesienia. Usunięcie składnika systematycznego ze zbioru obserwacji pozwala uzyskać zmniejszenie błędów prawdziwych wyznaczenia położenia punktu. Na dokładność wyznaczenia położenia współrzędnych punktu mają też wpływ różne inne czynniki: liczba widocznych nad horyzontem satelitów, jakość geometrii wyznaczenia (PDOP), wykorzystanie systemu EGNOS, czynniki zakłócające oraz czas pozyskiwania wyników na stanowisku. Analizując tę ostatnią przyczynę, ustalono na podstawie badań, że wiarygodne wyniki otrzymuje się dopiero po około 2 minutach od rozpoczęcia obserwacji na stanowisku.
Analysing the results of determining x, y coordinates of a single point position by GPS hand held receiver leads to find out a systematic component. It exists for different types of receivers, in different provinces, in different reference systems. Elimination of this bias from the set of observations makes it possible to diminish true values of errors of determination of point location. There are some other different sources of errors in determination of point location: number of satellites in view, quality of their geometry (PDOP), using EGNOS system, multipath errors and also observation time at the station. Researching the latter error it was found out, that reliable results are optainable after 2 minutes since the observation started.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 12
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokladnosci stosowanej w praktyce metody okreslania miazszosci drzewostanu na przykladzie drzewostanow brzozowych
Autorzy:
Rymer-Dudzinska, T.
Powiązania:
https://bibliotekanauki.pl/articles/818086.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
miazszosc drzewostanow
metoda Bitterlicha
tablice Tramplera
lesnictwo
dokladnosc
drzewostany brzozowe
Źródło:
Sylwan; 2001, 145, 06; 49-54
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury pracy na właściwości metrologiczne elektronicznych przekładników prądowych z uwzględnieniem właściwości rdzenia magnetycznego
The influence of operating temperature on metrological properties of electronic current transducers, including the magnetic core
Autorzy:
Szczęsny, A.
Powiązania:
https://bibliotekanauki.pl/articles/155948.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rdzeń magnetyczny
temperatura pracy
dokładność przetwarzania
magnetic core
operating temperature
Opis:
: W przekładnikach elektronicznych strumień magnetyczny wytworzony przez przewód z prądem pierwotnym jest skupiany w rdzeniu magnetycznym i mierzony przez czujnik Halla umieszczony w szczelinie tego rdzenia, poprzecznie do linii sił pola magnetycznego. Na właściwości metrologiczne wymienionych układów ma przede wszystkim wpływ materiał używany do konstrukcji obwodu magnetycznego przekładnika, jego konstrukcja oraz wpływ zmiany parametrów elementów półprzewodnikowych [1]. W artykule przedstawione zostały wyniki oraz wnioski z przeprowadzonych badań laboratoryjnych, obrazujących wpływ termicznych zmian wymiarów geometrycznych rdzenia magnetycznego na właściwości metrologiczne elektronicznych przekładników prądowych, pracujących w pętli zamkniętej.
Electronic transducers are used for measurements of variable, distorted, pulsed currents with galvanic isolation between the primary (power) and secondary (electronic systems) circuit. The operation of these systems is based on measurement of the magnetic field generated around the cable with a measured current, without power consumption from the primary circuit. For this purpose, the magnetic flux generated by the primary current, concentrated in the magnetic core, is compensated and a Hall effect sensor located in the gap of the core across to the force lines of the magnetic field determines the level of compensation. The metrological parameters of these systems are, first of all, dependent on the properties of the material used for construction of the transducer magnetic circuit and geometrical dimensions of the core [1]. The paper presents the results and conclusions of the laboratory research demonstrating the effect of thermal changes of magnetic core dimensions on the metrological parameters of electronic current transducers working in closed loop. Increase in the temperature influences the accuracy of converting the signals by electronic transformers, because it causes the changes of the magnetic core properties and the operating point of the electronic circuits used in a negative feedback loop.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 6, 6; 537-541
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność dodatkowych parametrów wyrównania w aerotriangulacji
Efficiency of additional parameters in aerialtriangulation
Autorzy:
Ziobro, J.
Powiązania:
https://bibliotekanauki.pl/articles/130472.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
aerotriangulacja
wyrównanie
dodatkowe parametry
dokładność
aerialtriangulation
additional parameters
adjustment
accuracy
Opis:
Przedstawiono wyniki badań skuteczności dodatkowych parametrów w aerotriangulacji na przykładzie bloków opracowanych w kraju, w kilku ostatnich latach. Zamieszczono wyniki badania 20 bloków podzielonych na cztery grupy, różniące się skalą zdjęć, liczbą zdjęć w bloku oraz występowaniem pomiaru środków rzutu. Pierwsza grupa zwierała 8 bloków, które opracowano dla map rzek ze zdjęć o skali 1:26 000. Bloki miały nieregularny kształt granic z wieloma załamaniami. Liczba zdjęć w blokach wynosiła od 50 do 133. Druga grupa zawierała 4 bloki opracowane dla numerycznego modelu terenu i ortofotomap ze zdjęć w skali 1:26 000. Bloki miały kształt prostokątny. Liczba zdjęć wynosiła od 384 do 1 077. Trzecia grupa zawierała 5 bloków, które opracowano dla numerycznego modelu terenu i ortofotomap ze zdjęć w skali 1:13 000. Bloki miały kształt prostokątny. Liczba zdjęć w bloku wynosiła od 888 do 2 263. Czwarta grupa zawierała 4 bloki opracowane dla map drogowych ze zdjęć w dużych skalach. Liczba zdjęć w bloku wynosiła od 93 do 241. Kształt bloków był nieregularny. Bloki w grupach trzeciej i czwartej miały pomiar środków rzutu metodą GPS. Liczba punktów kontrolnych w bloku wynosiła od 20 do 54. Punktami kontrolnymi i fotopunktami były szczegóły terenowe. Bloki wyrównano dwukrotnie: bez dodatkowych parametrów i z nimi. Bloki wyrównano programem BINGO, który ma funkcję zawierającą 24 parametry. Skuteczność dodatkowych parametrów pokazano jako wzrost dokładności uzyskanej dla punktów kontrolnych, w odniesieniu do dokładności otrzymanej w wyrównaniu bez dodatkowych parametrów. Dla 15 bloków dokładność wzrosła od 1 % do 70 %. Dla 5 bloków zmniejszyła się od 6 % do 16 %. Obniżenie dokładności powstało na skutek nieregularnego kształtu bloków lub nietypowej sieci fotopunktów.
This article presents the results of studies related to the efficiency of applying additional parameters in aerotriangulation, using study blocks prepared in Poland in recent years. The results of the study of 20 blocks are included and are divided into four groups, differing in photo scale, number of photographs within a block and appearance of the measured projection center. The first group consisted of 8 blocks which were prepared for river maps from 1:26 000 scale photographs. The blocks had very irregular border shapes with many corners. The number of photographs in blocks was from 50 to 133. The second group consisted of 4 blocks which were prepared for digital terrain models and for orthophotomaps from 1: 26 000 scale photographs. The blocks had a rectangular shape. The number of photographs in the blocks was from 384 to 1 077. The third group consisted of 5 blocks which were prepared for digital terrain models and for orthophotomaps from 1: 13 000 scale photographs. The blocks had a rectangular shape. The number of photographs in the blocks was from 888 to 2 263. The fourth group consisted of 3 blocks which were prepared for road maps from large scale photographs. The number of photographs in the blocks was from 93 to 241. The shape of blocks was irregular. The blocks in the third and fourth group had projection centers measured by GPS. The number of check points in the blocks was from 20 to 54. The control points and check points were terrain features. The blocks were adjusted twice: both with and without additional parameters. Adjustments were prepared by BINGO software, which has functions consisting of 24 parameters. The efficiency of additional parameters was demonstrated as an increase of accuracy obtained for check points, in reference to the accuracy achieved in adjustment without additional parameters. The accuracy was increased for 15 blocks from 1 % to 70 %. For 5 blocks, it was reduced from 6 % to 16 %. The accuracy decrease appeared as a result of irregular block shape or an untypical net of control points.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 619-626
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy ewidencjonowania ruchu i stanu zasobów złóż wapieni
Selected problems of the recording of change and state of limestone deposit resources
Autorzy:
Mucha, J.
Wasilewska-Błaszczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/394803.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wapienie
zasoby
geostatystyka
dokładność
ewidencja
limestones
resources
geostatistics
accuracy
registration
Opis:
Przedstawiono zalety i wady modelowania i szacowania zasobów złóż wapieni metodami tradycyjnymi i geostatystycznymi 3D. Skomentowano obowiązujące w Polsce wymagania dotyczące dokładności szacowania zasobów złóż na tle prognozowanych (teoretycznych) błędów oszacowań zasobów wapieni i sposobu zapisu wielkości ich zasobów. Stwierdzono, że notacja wielkości zasobów w różnego rodzaju dokumentach nie jest właściwa, gdyż nie odzwierciedla dokładności ich oszacowań. Zaproponowano wykazywanie wielkości zaktualizowanych zasobów złóż wapieni w corocznych bilansach zasobów złóż kopalin z dokładnością do 100 tys. ton oraz w operatach ewidencyjnych z dokładnością do 1 tys. ton.
The advantages and disadvantages of modelling and estimation of limestone deposit resources with traditional and geostatistical methods were presented. Current Polish requirements concerning the accuracy of deposit resources assessment related to predicted (theoretical) errors of limestone resources assessment were commented. It was stated that the notation of the amount of resources recorded in different documents is not correct, because it does not reflect the accuracy of resources assessment. The notation of the amount of updated limestone resources in annual register of mineral deposits in Poland accurate to within 100,000 metric tons and in annual resources reports accurate to within 1,000 metric tons, was proposed.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2014, 88; 175-182
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Test of impact of vibrations frequency on mean errors of the precise height differences measurement with analogue automatic leveller NI002
Badanie wpływu częstotliwości drgań na średnie błędy pomiaru przewyższeń w precyzyjnym niwelatorze analogowym NI 002
Autorzy:
Kurnatowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/396023.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
vibrations
measurement accuracy
precise levelling
drgania
dokładność pomiaru
niwelacja precyzyjna
Opis:
The article describes the results of tests carried out to determine the measurable effect of vibrations on the accuracy of measurements with an automatic precise leveller. It contains specification of the research station created to examine the case and description of factors affecting the measurement results. The multi-frequency vibrations were forced on a leveller during measurements and calculated mean errors for each frequency analysed. The range of frequencies for which the measurement was possible was estimated. The obtained results can be helpful in the engineering measurements designing, especially in industrial areas, where vibrations are an inseparable element of the environment.
Artykuł opisuje wyniki badań przeprowadzonych w celu określenia wymiernego wpływu drgań na dokładności pomiaru analogowym niwelatorem precyzyjnym pojedynczego przewyższenia. Opisano stanowisko badań oraz generator wstrząsów, jakie stworzono na potrzeby zbadania problemu oraz czynniki wpływające na wyniki pomiarów. Porównano wartości błędów średnich uzyskanych w wyniku pomiarów przeprowadzonych niwelatorem pobudzonym do drgań o różnych częstotliwościach i oszacowano przedziały tych częstotliwości, dla których pomiar był możliwy. Analizie poddano również otrzymane wartości przewyższeń, zmierzone przy różnych częstotliwościach drgań. Otrzymane wyniki mogą być pomocne przy projektowaniu pomiarów inżynierskich w warunkach przemysłowych, gdzie wstrząsy są nieodłącznym elementem środowiska.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(4); 129-137
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność obróbki elementów wielkogabarytowych – zagadnienia technologiczne
Large-size elemets machining accuracy – technological problems
Autorzy:
Styp-Rekowski, M.
Matuszewski, M.
Oborski, I. L.
Bromberek, F.
Powiązania:
https://bibliotekanauki.pl/articles/404449.pdf
Data publikacji:
2015
Wydawca:
Wydawnictwo AWART
Tematy:
obróka elementów wielkogabarytowych
dokładność
machining
machining accuracy
large-size element
Opis:
W artykule przedstawiono czynniki technologiczne determinujące dokładność obróbki elementów, zwłaszcza wielkogabarytowych. Przedstawiono także sposoby aby zminimalizować negatywny wpływ tych czynników na dokładność wymiarową elementów.
In the paper there were presented technological factors which determine element's machining accuracy, particularly large-size elements. The ways which enable minimization their negative influence on dimensional accuracy were presented too.
Źródło:
Obróbka Metalu; 2015, 3; 11-14
2081-7002
Pojawia się w:
Obróbka Metalu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie dokładnością obróbki wałków o małej sztywności
Accuracy control in the machining of low rigidity shafts
Autorzy:
Świć, A
Wołos, D.
Powiązania:
https://bibliotekanauki.pl/articles/269441.pdf
Data publikacji:
2014
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
sterowanie
dokładność obróbki
wałek
sztywność
control
accuracy machining
shaft
rigidity
Opis:
Określono najodpowiedniejszy schemat ustalenia i zamocowania wałków o małej sztywności oraz czynniki umożliwiające taki wybór, a w trakcie mocowania oprócz zamykania siłowego jest realizowane również zamykanie kinematyczne. Opracowano sposób obróbki mechanicznej wałków o małej sztywności, umożliwiający sterowanie stanem sprężyście – odkształcalnym wałków w układzie technologicznym oraz osiągnięcie wymaganej dokładności w czasie toczenia. Zaprojektowano urządzenie, realizujące opracowany sposób obróbki mechanicznej wałków o małej sztywności, umożliwiające zwiększenie sztywności wałka w trakcie obróbki w wyniku przyłożenia do części osiowej siły rozciągającej. Urządzenie stabilizuje odkształcenia sprężyste części w stanach ustalonych i przejściowych oraz podwyższa dokładność obróbki wałków o małej sztywności. Określono racjonalne koszty własne przygotowania baz technologicznych, na etapie technologicznego przygotowania produkcji, co daje możliwość wyboru odpowiedniej technologii obróbki wałków o małej sztywności, konstruowania zorientowanego technologicznie oraz zmniejszenia kosztów obróbki wałków.
The study determines the most suitable pattern of alignment and fixing of low-rigidity shafts; it also presents factors that determine such choice. The part is fixed both by force closing and kinematic closing. A new method for machining low rigidity shafts is developed to control the elastic-deformable state of these shafts in a technological system and to produce parts with the required accuracy during turning. To implement this new developed method for low rigidity shafts, an apparatus is designed. The apparatus allows to increase the rigidity of shafts during machining by the application of axial tensile force to the workpiece. The apparatus stabilizes elastic deformations in the workpiece both in a steady state and under transitory conditions; it also increases the machining accuracy of low rigidity shafts. Rational prime costs of preparing technological alignment centers at the stage of production preparation are determined; knowing these costs, it is possible to select a suitable machining technology for low rigidity shafts, to produce a technology oriented design, and to reduce the costs of machining these shafts.
Źródło:
Inżynieria Maszyn; 2014, R. 19, z. 1; 62-77
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie programu GAPS do pozycjonowania kinematycznego
Application of GAPS Software for Kinematic Positioning
Autorzy:
Krasuski, K.
Powiązania:
https://bibliotekanauki.pl/articles/403673.pdf
Data publikacji:
2016
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
GPS
GAPS
metoda PPP
dokładność pozycjonowania
PPP method
positioning accuracy
Opis:
W artykule przedstawiono wyniki badań dotyczących wyznaczenia pozycji statku powietrznego w trybie kinematycznym w systemie GPS. W obliczeniach użyto dwuczęstotliwościowych obserwacji kodowo-fazowych GPS z odbiornika Topcon TPS Hiper. Pozycja samolotu została wyznaczona w komercyjnym oprogramowaniu GAPS, przy zastosowaniu metody PPP. Dodatkowo, w artykule scharakteryzowano program GAPS oraz metodę PPP. Wstępne rezultaty z programu GAPS umożliwiają osiągnięcie dokładności około 0,035 m dla współrzędnych horyzontalnych oraz ponad 0,06 m dla współrzędnej wertykalnej. W artykule porównano również wartości błędów średnich z programu GAPS i CSRS-PPP oraz wyznaczono parametr RMS dla wysokości elipsoidalnej H.
The paper presents the results on determination of aircraft’s position in kinematic mode in GPS system. The dual-frequency code and phase observations from Topcon TPS Hiper receiver were used for computations. The aircraft’s position in commercial GAPS software was estimated using PPP method. In addition, the GAPS software and PPP method were characterized. Preliminary results from GAPS software show that accuracy for horizontal coordinates is about 0.035 m and for vertical coordinate it is more than 0.06 m, respectively. Mean errors from GAPS and CSRS-PPP software were also compared and RMS parameter for the ellipsoidal height H was determined.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2016, 7, 2 (24); 117-130
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wzorcowania łat na dokładność niwelacji precyzyjnej
Effect of rod’s calibration on accuracy of precise leveling
Autorzy:
Frukacz, M.
Jasinska, E.
Preweda, E.
Powiązania:
https://bibliotekanauki.pl/articles/62192.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
niwelacja precyzyjna
dokladnosc pomiaru
sprzet geodezyjny
laty niwelacyjne
kalibracja
wzorcowanie
Opis:
Konieczność okresowego badania sprzętu geodezyjnego, nakładana na wykonawców m.in. przez instrukcje techniczne, często traktowana jest w wykonawstwie geodezyjnym jako „zło konieczne". Badania prowadzone w Geodezyjnym Laboratorium Metrologicznym AGH pokazują, że okresowe wzorcowanie instrumentów i przymiarów geodezyjnych pozwala nie tylko wykrywać i opisywać błędy systematyczne, ale także generować wnioski dotyczące prawidłowego użytkowania sprzętu, co z kolei prowadzi do zachowania dokładności pomiarów wymaganej przepisami. W prezentowanym artykule przedstawiono wnioski z laboratoryjnych badań łat do niwelacji precyzyjnej, które uwzględnione przez wykonawców mogą przyczynić się do podniesienia dokładności niwelacji precyzyjnej. Uwagi te są szczególnie istotne dla pomiarów prowadzonych w terenach o dużych deniwelacjach terenów oraz niwelacji wysokich obiektów hydrotechnicznych.
The need for periodic testing of surveying equipment is often treated by surveyors as a "necessary evil". Research conducted in the Metrological Geodetic Laboratory GLM AGH shows that the periodic calibration of surveying instruments allows to detect and describe the systematic errors, and generate proposals for the proper use of equipment, which leads to maintaining the accuracy required under the legislation.The article presents conclusions from laboratory tests of leveling rods, which can help to improve the accuracy of precise leveling. These considerations are particularly important for measurements carried out in the mountains and in engineering measurements of the highest accuracy.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 04
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Z problematyki określenia dokładności map izopletowych
Problems in establishing the accuracy of isopleth maps
Autorzy:
Cebrykow, P.
Powiązania:
https://bibliotekanauki.pl/articles/204355.pdf
Data publikacji:
2004
Wydawca:
Polskie Towarzystwo Geograficzne
Tematy:
mapa
mapa izopletowa
dokładność map
map
isopleth map
accuracy of map
Opis:
W artykule opisano problemy związane z badaniem dokładności map izopletowych oraz przedstawiono źródła błędów na takich mapach.
The isopleth method is rarely used as a presentation method in cartography. There are several reasons for that. One of the main causes is cartographers' distrust towards isopleths, which bases on opinions of many cartographic authorities (Eckert, Imhof, Salishchev). The main dilemma is whether it is possible to represent discontinuous phenomena with isolines. The fact that this method is highly labor-consuming also limited its popularity. Furthermore, there are no clear, acknowledged criteria for preparation of isopleth maps. In order to establish how isopleth maps should be prepared one has to determine a universal tool for their evaluation. Volumetric criterion proposed by J.Moscibroda (1999) seems to be the optimal solution. In short, it preserves unity of a statistic volume of an isopleth map with the volume of continuous choropleth. Application of a criterion of behavior of phenomenon's statistical volume helps to trace down the sources of errors, which appear on traditional isopleth maps. The research made it possible to determine three basic factors which cause errors to appear. They are: the type of basic space units, location and number of reference points and the method of interpolation. Knowing the origin of errors and being able to evaluate them on isopleth maps provides a basis for research on how to improve the methods of their elaboration.
Źródło:
Polski Przegląd Kartograficzny; 2004, T. 36, nr 4, 4; 259-265
0324-8321
Pojawia się w:
Polski Przegląd Kartograficzny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania symulacyjne agrorobota w aspekcie dokładności pozycjonowania
Simulations of agro-robot in terms of positioning accuracy
Autorzy:
Graboś, A.
Boryga, M.
Powiązania:
https://bibliotekanauki.pl/articles/290816.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
agrorobot
kinematyka
dynamika
symulacja
dokładność pozycjonowania
kinematics
dynamics
simulation
positioning accuracy
Opis:
W pracy przedstawiono sposób modelowania oraz wyniki komputerowej symulacji ruchu agrorobota, którego zespół pozycjonowania posiada trzy stopnie swobody. Analizę kinematyki przeprowadzono metodą macierzową. Równania ruchu wyprowadzono na podstawie równań Lagrange’a II rodzaju. Badania symulacyjne, dla trzech wybranych prędkości chwytaka, przeprowadzono w programie Matlab (Simulink). Wyniki przedstawiono w postaci czasowych przebiegów błędów realizacji zamierzonego toru ruchu.
The paper presents modelling methods and output of computer aided simulation of agro-robot movement, the positioning system of which has three degrees of free motion. The kinematics analysis was carried out with the matrix method. Motion equations were derived from the Lagrange equations of the second type. Simulations, for three selected speeds of the gripping device, were made using the Matlab (Simuling) application. The results were presented in a form of time runs of trajectory following errors.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 6, 6; 205-214
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczna dokladnosc wzoru Gieruszynskiego w porownaniu z innymi wzorami dendrometrycznymi
Autorzy:
Meixner, J.
Powiązania:
https://bibliotekanauki.pl/articles/811310.pdf
Data publikacji:
1994
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
miazszosc strzaly
dendrometria
wzory dendrometryczne
sosna
dokladnosc pomiaru
wzor Gieruszynskiego
lesnictwo
Źródło:
Sylwan; 1994, 138, 04; 5-14
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokladnosci inwentaryzacji drzewostanow sosnowych wykonywanej za pomoca probnych powierzchni relaskopowych
Autorzy:
Borecki, T.
Miscicki, S.
Nowakowska, J.
Stepien, E.
Wojcik, R.
Powiązania:
https://bibliotekanauki.pl/articles/819904.pdf
Data publikacji:
1999
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
drzewostany sosnowe
powierzchnie probne relaskopowe
zasoby drzewne
lesnictwo
inwentaryzacja lasu
dokladnosc
Źródło:
Sylwan; 1999, 143, 03; 33-41
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność tablic miąższości Bolesława Radwańskiego dla grubizny drzewostanów sosnowych powyżej 80 lat
Tochnost tablic Boleslava Radvanskogo dlja tolstomernojj drevesiny sosnovykh nasazhdenijj vozrastom vyshe 80 let
Die Genauigkeit der Derbholzmassentafeln von Boleslaw Radwanski fur Kiefernbestande uber 80 Jahre
Autorzy:
Grochowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/822793.pdf
Data publikacji:
1971
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
lesnictwo
dendrometria
drzewostany sosnowe
miazszosc drzew
tablice miazszosci
tablice Radwanskiego
dokladnosc
Źródło:
Sylwan; 1971, 115, 02
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokladnosci okreslania piersnicowej liczby ksztaltu grubizny drzewa za pomoca tablic Tramplera dla drzewostanow bukowych
Autorzy:
Dudzinska, M.
Powiązania:
https://bibliotekanauki.pl/articles/814305.pdf
Data publikacji:
2002
Wydawca:
Polskie Towarzystwo Leśne
Tematy:
drzewostany bukowe
miazszosc drzewostanow
tablice Tramplera
lesnictwo
dokladnosc
piersnicowa liczba ksztaltu
Źródło:
Sylwan; 2002, 146, 03; 63-71
0039-7660
Pojawia się w:
Sylwan
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwagi o rejestracji przebiegów czasowych z jednoczesną prognozą ich zmian
The Remarks on Recording of Time Variable Signals with Simultaneous Prediction of Signal Changes
Autorzy:
Żuchowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/154094.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rejestracja przebiegów
prognozy
dokładność prognoz
signal recording
prediction
accuracy of prediction
Opis:
Rozpatrzono koncepcję rejestracji przebiegów czasowych y(t) z jednoczesnym zapisem prognozy ich zmian y(t+tp) w pewnym przedziale od 0≤tp≤tp max. Rozpatrzono kilka koncepcji procedur prognozowania, ich błędy i zakres tp max.
The idea for recording of time variable signals y(t) with simultaneous recording of signal prediction y(t+tp) for certain from 0≤tp≤tp max as been considered in the paper. The errors and ranges of tp max for several ideas of prediction procedures have been discussed.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 183-185
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The precision of compass error observation using parallel lines option in radar
Dokładność określenia poprawki kompasu przy wykorzystaniu opcji linii równoległych w radarze
Autorzy:
Lushnikov, E. M.
Pleskacz, K.
Powiązania:
https://bibliotekanauki.pl/articles/359562.pdf
Data publikacji:
2012
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
dokładność
poprawka kompasu
radar
linie rownoległe
accuracy
compass correction
parallel lines
Opis:
The article presents a method to determine the gyro correction by utilizing parallel lines used in radar, taking into account the advantages of this method, which are the convenience and ease of use. The accuracy of the method according to the geographical and technical factors was analyzed. The mathematical calculation of the final results accuracy was presented. Situations in which it is recommended to use this method for determining gyrocompass corrections due to the high accuracy were described.
W artykule zaprezentowano metodę określenia poprawki żyrokompasu przy wykorzystaniu linii rownoległych stosowanych w radarze. Uwzględniono zalety tej metody, którymi są szybkość i łatwość stosowania. Przeanalizowano dokładność metody w zależności od warunków geograficznych i czynników technicznych. Przedstawiono matematyczne wyliczenia dokładności wyników końcowych. Opisano sytuacje, w których rekomendowane jest stosowanie tej metody określania poprawki żyrokompasu ze względu na wysoką dokładność.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2012, 29 (101); 126-129
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ryzyko operacji lotniskowych a dokładność pozycjonowania (RNP)
Required navigation performance and risk of airport operations
Autorzy:
Banaszek, K.
Malarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/257721.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
ruch lotniczy
nawigacja satelitarna
dokładność pozycjonowania
RNP
air traffic
satellite navigation
Opis:
W artykule opisano wymagania Międzynarodowej Organizacji Lotnictwa Cywilnego ICAO dla realizacji systemu nawigacyjnego GNSS. Dokument ICAO - RNP określa wymagania nawigacyjne dla lepszego pozycjonowania samolotu w rejonie portów lotniczych. Ich wprowadzenie pozwoli zwiększyć bezpieczeństwo operacji w rejonie portów lotniczych. Badania w tym zakresie podjęto również w Polsce. W 2010 planowane jest testowanie systemu nawigacyjnego EGNOS w zakresie możliwości wykorzystania do pozycjonowania samolotu w trakcie operacji lotniskowych: podejścia do lądowania i lądowania przy spełnieniu minimalnych wymagań nawigacyjnych na poziomie RNP-0.3.
This paper covers the requirements of International Civil Aviation Organisation (ICAO) for the Performance Based Navigation and utilisation of the GNSS system. ICAO - RNP (Required Navigation Performance) and PBN are enablers for better positioning of the aircraft and separation minima, allowing an increase in the capacity in airspace. In 2010, EGNOS will become fully functional and operational. The European navigation system and will be used for approach and landing phases of flights enabling the implementation of (minimum) RNP-0.3 requirements in the airport area.
Źródło:
Problemy Eksploatacji; 2009, 4; 71-78
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Some remarks on evaluating the quality of the multiple sequence alignment based on the BAliBASE benchmark
Autorzy:
Błażewicz, J.
Formanowicz, P.
Wojciechowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/930013.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
dostosowanie odniesienia
dokładność ustawienia
multiple sequence alignment
reference alignment
alignment accuracy
Opis:
BAliBASE is one of the most widely used benchmarks for multiple sequence alignment programs. The accuracy of alignment methods is measured by bali score-an application provided together with the database. The standard accuracy measures are the Sum of Pairs (SP) and the Total Column (TC). We have found that, for non-core block columns, results calculated by bali score are different from those obtained on the basis of the formal definitions of the measures. We do not claim that one of these measures is better than the other, but they are definitely different. Such a situation can be the source of confusion when alignments obtained using various methods are compared. Therefore, we propose a new nomenclature for the measures of the quality of multiple sequence alignments to distinguish which one was actually calculated. Moreover, we have found that the occurrence of a gap in some column in the first sequence of the reference alignment causes column discarding.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2009, 19, 4; 675-678
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie deformacji ciągłych powierzchni terenu w warunkach zmiennego zalegania złoża
Modeling continuous deformation of terrain in variable conditions of deposition
Autorzy:
Hejmanowski, R.
Kwinta, A.
Powiązania:
https://bibliotekanauki.pl/articles/216115.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
deformacje górotworu
modelowanie
dokładność
prognoza
rock mass deformation
modeling
accuracy
prediction
Opis:
Ciągłe deformacje powierzchni terenu wywołane podziemną eksploatacją górniczą mogą powodować zagrożenie budynków i infrastruktury. Zagadnienie modelowania deformacji od strony teoretycznej jest znane od wielu lat. Powszechnie stosowany jest model Knothego. Dokładność prognozowanych deformacji zależy w dużej mierze od prawidłowej identyfikacji parametrów modelu i warunków zalegania przewidzianego do eksploatacji złoża. W pracy przedstawiono charakterystykę metodyki modelowania warunków zalegania złoża w informatycznym systemie prognozowania MODEZ. Pozwala ona na uwzględnienie zmienności parametrów zalegania złoża i parametrów górniczo-geologicznych eksploatacji. W konsekwencji daje to znaczną poprawę jakości prognoz deformacji.
Surface subsidence induced by underground mining activity may cause danger to buildings and infrastructure. The issue of the surface subsidence modelling is known for many years. The Knothe's theory is the most often used method of surface deformation modelling. Surface subsidence predictions accuracy depends mainly on the correct identification of model parameters and geometrical conditions of the strata occurrence. The paper presents a methodology for modelling of the seam occurrence in the computer system called MODEZ. That program is dedicated to surface subsidence prognosis. Shown system enables to take into account not only the variability of the seam deposit parameters but also the exploitations parameters. As a result it gives considerable improvement of the accuracy of the surface subsidence prognosis.
Źródło:
Gospodarka Surowcami Mineralnymi; 2010, 26, 3; 143-153
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of panchromatic IKONOS data for mapping
Ocena przydatności panchromatycznych obrazów IKONOS dla opracowania map
Autorzy:
Kaczyński, R.
Ewiak, I.
Chun, R. W.
Hui, Y. M.
Powiązania:
https://bibliotekanauki.pl/articles/129670.pdf
Data publikacji:
2001
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
Ikonos
orthorectification
panchromatic data
planimetric accuracy
ortorektyfikacja
dane panchromatyczne
dokładność planimetryczna
Opis:
The results of assessment of the planimetric accuracy of 1-meter resolution panchromatic IKONOS data comparing to the topographic map in the scale 1:10,000 are presented. Low precision georeferenced Car terra Geo, 50 m CE90 product of test areas in China was orthorectified in IGiK using Image Station INTERGRAPH and InternationaI Imaging System PRISM VISTA software as well as software elaborated in Chinese Academy of Surveying and Mapping (CASM). Planimetric accuracy of IKONOS data after adjustment with the use of 5 GCP's (taken from the topomap) was: RMSEx = +/- 1.1m and RMSEy = +/- 1.4m. Planimetric accuracy calculated on 18 check points, the X, Y coordinates of which have been also taken from the topomap was: RMSEx = +/-3.5m and RMSEy= +/- 2.5 m. Planimetric accuracy of the orthophotomap generated using IKONOS data and calculated transformation parameters was: RMSEx = +/- 3.7 m and RMSEy = +/- 3.6 m. This accuracy is similar to the planimetric accuracy of the topographic map in the scale 1:10 000. Better accuracy can be achieved by measuring GCP's directly in the field with GPS technique instead of using topomaps. Nevertheless, Сarterra Geo product which is of the lowest horizontal precision out of the entire range of IKONOS products and also the cheapest, can be used for updating topomaps as well as for generating up-to-date digital basemap in modern Geographic Information Systems.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2001, 11; 3-1-3-6
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lotniczy skaning laserowy LIDAR miasta Krakowa (ocena dokładnościowa)
Aerial laser scanning LIDAR of the area of Krakow (precision analysis)
Autorzy:
Borowiecki, I.
Slusarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/61668.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
miasta
Krakow
lotniczy skaning laserowy
lidar
dokladnosc pomiaru
numeryczny model terenu
Opis:
Artykuł przedstawia charakterystykę technologii lotniczego skaningu laserowego LIDAR, architekturę systemu, jej wady i zalety oraz ocenę dokładności. Analizę dokładnościową lotniczego skaningu laserowego wykonano na podstawie danych pomiaru lidarowego miasta Krakowa z 2006 roku (ocena dokładności współrzędnych X, Y, Z na obiekcie: Uniwersytet Rolniczy ul. Balicka oraz Wzgórze Wawelskie). W procesie analizy dokładnościowej zaproponowano obliczenie średniego błędu kwadratowego położenia RMSEX RMSEY RMSEXY , średniego błędu kwadratowego wysokości RMSEZ, dokładności wysokościowej DZ oraz obliczenie częstości odchyłek dx, dy i dz wyrażonej w procentach.
In the article a technology of the aerial laser scanning (LIDAR) was characterized as well as the system architecture its drawbacks and advantages and a precision analysis. The precision analysis of the aerial laser scanning was carried out on the basis of the lidar measurements of Krakow data collected in 2006. For the precision test of the X, Y, Z coordinates two objects were used: the University of Agriculture (Balicka street in Krakow) and the Wawel Hill. In the process of the precision analysis calculations of the mean square errors of the position RMSEX RMSEY RMSEXY , mean square error of the height RMSEZ and the height precision DZ were proposed as well as calculation of the percentage of the deviation frequency.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2010, 03
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization GPS/QZSS Data for Determination of User’s Position I
Wykorzystanie obserwacji GPS/QZSS do wyznaczania pozycji użytkownika
Autorzy:
Krasuski, K.
Powiązania:
https://bibliotekanauki.pl/articles/277579.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
GPS
QZSS-Zenith
SPP method
positioning accuracy
metoda SPP
dokładność pozycjonowania
Opis:
This paper presents studies results of standalone positioning, based on GPS/QZSS observations. For this purpose C1 code observations from STK2 station (IGS station in Japan) were used. Computations in RTKLIB software (RTKPOST module) were executed and SPP method was used to position estimation. In the paper two experiments were realized: firstly user’s position was estimated based on GPS observations, and in second case QZSS observations were applied also. Preliminary results of positioning accuracy show that GPS/QZSS solution improve accuracy of X coordinate about 0.398 m, accuracy of Y coordinate about 0.432 m and accuracy of Z coordinate about 0.285 m, respectively. Additionally RMS-3D error was estimated based on coordinates differences from GPS and GPS/QZSS solutions. Average value of RMS-3D term equals to 0.986 m, with magnitude order between 0.003 m and 3.649 m.
Artykuł przedstawia wyniki badań dotyczących pozycjonowania absolutnego z wykorzystaniem obserwacji GPS/QZSS. W ramach przeprowadzonych badań zostały wykorzystane obserwacje kodowe C1 ze stacji STK2 (stacja IGS na terenie Japonii). Obliczenia zostały zrealizowane w programie RTKLIB (w module RTKPOST), a do wyznaczenia pozycji została zaproponowana metoda pozycjonowania absolutnego (SPP). W eksperymencie badawczym wykonano 2 testy: w pierwszym pozycja użytkownika została wyznaczona na podstawie obserwacji GPS, a w drugim na podstawie obserwacji GPS/QZSS. Wstępne wyniki dokładności pozycjonowania są obiecujące, na podstawie obserwacji GPS/QZSS. Rozwiązanie GPS/QZSS poprawiło odpowiednio błędy średnie współrzędnej X o 0,398 m, współrzędnej Y o 0,432 m, zaś współrzędnej Z o 0,285 m. Dodatkowo błąd RMS-3D został wyznaczony na podstawie różnicy współrzędnych z rozwiązania GPS oraz GPS/QZSS. Średnia wartość tego parametru wyniosła 0,986 m, dla przedziału wartości od 0,003 m do 3,649 m.
Źródło:
Pomiary Automatyka Robotyka; 2015, 19, 2; 71-75
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Divagations on the appropriate satellite system from GNSS for aviation
Dywagacje na temat odpowiedniego z GNSS systemu satelitarnego dla lotnictwa
Autorzy:
Fellner, Andrzej
Konieczka, Robert
Powiązania:
https://bibliotekanauki.pl/articles/36435763.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
GPS
reliability
precision
consistency
availability
GNNS
wiarygodność
dokładność
ciągłość
dostępność
GNSS
Opis:
American military satellite GPS system is an element of the global GNSS. It emits two codes: the precise and civil one. As late as in 2000, intentional interference that decreased precision of localization was introduced, allowing navigation accuracy of 20 m. GPS was made available to civil users, however, at their own responsibility. So, if we use GPS for our own goals, we must consider the errors that occur and their consequences. Nonetheless, commercial and operational needs determine the necessity of permanent access to satellite signal with appropriate consistency, accessibility, reliability and precision. Hence, natural and intentional errors are compensated for, using appropriate methods, based on a given activity.
Amerykański, militarny system satelitarny GPS stanowi element globalnego GNSS. Emituje dwa kody: precyzyjny i cywilny. Dopiero w 2000 r. wyłączono celowe zakłócanie zmniejszające precyzję wyznaczania pozycji, pozwalające uzyskać dokładność nawigacji do 20 m. GPS został udostępniony użytkownikom cywilnym, ale na ich własną odpowiedzialność. Toteż o ile stosujemy GPS dla swoich potrzeb to musimy liczyć się z powstałymi błędami i wynikającymi z nich konsekwencjami. Jednak potrzeby komercyjne, operacyjne determinują konieczność permanentnego dostępu do sygnału satelitarnego, charakteryzującego się odpowiednią: ciągłością, dostępnością, wiarygodnością, dokładnością. W związku z tym naturalne i celowe błędy kompensuje się stosując odpowiednie metody, w zależności od prowadzonej działalności.
Źródło:
Transactions on Aerospace Research; 2021, 1 (262); 75-92
0509-6669
2545-2835
Pojawia się w:
Transactions on Aerospace Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technological quality of teeth of a cylindrical gears grinded with use of profile dividing method
Jakość technologiczna uzębień kół zębatych walcowych szlifowanych metodą kształtowo-podziałową
Autorzy:
Płonka, S.
Jędrzejczyk, D.
Zyzak, P.
Powiązania:
https://bibliotekanauki.pl/articles/175894.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
grinding of cylindrical gears
profile dividing grinding method
manufacturing accuracy
geometrical accuracy
surface layer
szlifowanie kół zębatych
metoda kształtowo-podziałowa
dokładność wykonania
dokładność geometryczna
warstwa wierzchnia
Opis:
The study presents investigation results of technological quality of teeth of a cylindrical gears made of 18CrMo4 steel, carburized, quenched and tempered, and grinded with use of profile dividing method on grinding machine of Höfler Rapid 900 type. It have been included investigation results of geometrical accuracy and selected properties of surface layer of the teeth after hobbing operation, thermal-chemical treatment and grinding operation.
W pracy przedstawiono analizę wyników badań jakości technologicznej uzębień kół zębatych walcowych ze stali 18CrMo4 nawęglanych, hartowanych i odpuszczanych oraz szlifowanych metodą kształtowo-podziałową na szlifierce Rapid 900 firmy Höfler. Wykonano badania dokładności geometrycznej i wybranych właściwości warstwy wierzchniej zębów obrobionych frezowaniem obwiedniowym oraz obrobionych cieplno-chemicznie i szlifowanych.
Źródło:
Advances in Manufacturing Science and Technology; 2018, 42, 1-4; 5-20
0137-4478
Pojawia się w:
Advances in Manufacturing Science and Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unbalanced multiclass classification with adaptive synthetic multinomial naive Bayes approach
Niezrównoważona klasyfikacja wieloklasowa z adaptacyjnym syntetycznym wielomianowym naiwnym podejściem Bayesa
Autorzy:
Fauzi, Fatkhurokhman
Ismatullah
Nur, Indah Manfaati
Powiązania:
https://bibliotekanauki.pl/articles/27315441.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
adaptive synthetic
classification
imbalance data
accuracy
adaptacyjna synteza
klasyfikacja
danedotyczące nierównowagi
dokładność
Opis:
Opinions related to rising fuel prices need to be seen and analysed. Public opinion is closely related to public policy in Indonesia in the future. Twitter is one of the media that people use to convey their opinions. This study uses sentiment analysis to look at this phenomenon. Sentiment is divided into three categories: positive, neutral, and negative. The methods used in this research are Adaptive Synthetic Multinomial Naive Bayes, Adaptive Synthetic k-nearest neighbours, and Adaptive Synthetic Random Forest. The Adaptive Synthetic method is used to handle unbalanced data. The data used in this study are public arguments per province in Indonesia. The results obtained in this study are negative sentiments that dominate all provinces in Indonesia. There is a relationship between negative sentiment and the level of education, internet use, and the human development index. Adaptive Synthetic Multinomial Naive Bayes performed better than other methods, with an accuracy of 0.882. The highest accuracy of the Adaptive Synthetic Multinomial Naive Bayes method is 0.990 in Papua Barat Province.
Należy przyjrzeć się i przeanalizować opinie związane z rosnącymi cenami paliw. Opinia publiczna jest ściśle związana z polityką publiczną Indonezji w przyszłości. Twitter jest jednym z mediów, których ludzie używają do przekazywania swoich opinii. Niniejsze badanie wykorzystuje analizę nastrojów, aby przyjrzeć się temu zjawisku. Opinia jest podzielona na trzy kategorie: pozytywną, neutralną i negatywną. Metody wykorzystane w tym badaniu to Adaptive Synthetic Multinomial Naive Bayes, Adaptive Synthetic k-nearest neighbours i Adaptive Synthetic Random Forest. Metoda Adaptive Synthetic służy do obsługi niezrównoważonych danych. Dane wykorzystane w tym badaniu to argumenty publiczne według prowincji w Indonezji. Wyniki uzyskane w tym badaniu to negatywne nastroje, które dominują we wszystkich prowincjach Indonezji. Istnieje związek między negatywnymi nastrojami a poziomem wykształcenia, korzystaniem z Internetu i wskaźnikiem rozwoju społecznego. Adaptive Synthetic Multinomial Naive Bayes działała lepiej niż inne metody, z dokładnością 0,882. Najwyższa dokładność metody Adaptive Synthetic Multinomial Naive Bayes wynosi 0,990 w prowincji Papua Barat.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 3; 64--70
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarys metody określania jakości systemu samonaprowadzania lotniczego pocisku rakietowego
Outline of the Method of an Aircraft Missile Homing System’s Quality Estimation
Autorzy:
Skomra, A.
Powiązania:
https://bibliotekanauki.pl/articles/403320.pdf
Data publikacji:
2016
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
mechanika
dokładność
samonaprowadzanie
uchyb rakiety
przelot
mechanics
accuracy
homing guidance
miss distance
Opis:
Jakość systemu samonaprowadzania określić można dokładnością naprowadzenia pocisku rakietowego na cel w ujęciu stochastycznym przez wyznaczenie wartości oczekiwanej i wariancji uchybu końcowego pocisku. W artykule przedstawiono metodę opisu rozkładu uchybu bieżącego pocisku, polegającą na wykorzystaniu funkcji charakterystycznej tej zmiennej losowej. Do wyprowadzenia końcowego wzoru na uchyb bieżący pocisku skorzystano z wyrażenia opisującego prędkość kątową linii obserwacji celu, będącego rozwiązaniem zlinearyzowanego układu równań, opisującego związki kinematyczne między pociskiem i celem wraz z algorytmem proporcjonalnej nawigacji.
Quality of the missile homing system can be determined by the homing accuracy in stochastic way through determination of the expected value and variance of the final miss distance. The paper presents description of a method of distribution of current miss distance between the missile and the target using a random variable’s characteristic function. With a view to obtain an expression of miss distance, the author uses a formula describing angular velocity of the line of sight which was the solution of linearized simultaneous equations describing kinematic connections between missile and target together with proportional navigation guidance law.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2016, 7, 2 (24); 73-88
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the effect of finishing work on the geometric accuracy of the laser cut elements
Autorzy:
Skoczylas, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/103107.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
laser cutting
geometric accuracy
finishing works
cięcie laserowe
dokładność geometryczna
prace wykończeniowe
Opis:
The article presents the results of geometric accuracy studies of the C45 steel elements after laser cutting, and then subjected to finishing work. Burnishing and a combined machining and burnishing were applied as finishing works. Geometric accuracy studies of the elements after laser cutting and after finishing work were conducted in accordance with the PN – EN ISO 9013: 2017 – 04 standard. It has been noted that the finishing machining enables the improvement of geometric accuracy of the surface after laser cutting. Machining of elements after laser cutting allows for a reduction of the inclination index of the surface up to 42% with respect to the index value after laser cutting. Finishing milling makes it possible to reduce the surface inclination index more than twice. By performing burnishing of elements after laser cutting and finishing milling, no significant improvement of the element accuracy is obtained.
Źródło:
Advances in Science and Technology. Research Journal; 2018, 12, 1; 267-272
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapewnienie stabilności pomiarów kontaktowych w systemie automatycznego sterowania precyzyjnym szlifowaniem
Ensuring the stability of contact measurements in automated control systems for precision grinding
Autorzy:
Sholom, P.
Powiązania:
https://bibliotekanauki.pl/articles/952708.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
pomiar
mechanizm przemieszczenia
odkształcenie
przemieszczenie
dokładność
measurement
transfer shift
deformation
displacement
accuracy
Opis:
Kontrola rozmiarów przedmiotów podczas ich obróbki na szlifierkach odbywa się za pomocą głowic pomiarowych ze specjalnym osprzętem, który znajduje się w mechanicznym kontakcie z kontrolowaną powierzchnią. Pomiar jest wykonywany w trybie automatycznym, dlatego ważne wyzwanie techniczne polega na tym, aby zapewnić wysoką dokładność śledzenia aktualnej wartości parametru kontrolnego. Rozpatrzono przyczyny występowania błędów pomiarowych. W artykule zostały przeanalizowane praktyczne układy kontroli przy szlifowaniu kształtów cylindrycznych oraz sytuacje, które mogą prowadzić do błędów temperaturowych lub jakości pozycjonowania osprzętu na powierzchni kontrolnej.
Control the size of the parts in the process of their processing on the grinding machine is performed using the measuring heads with a special equipment that mechanically is in contact with the surface of the control. The measurement is performed in the automatic mode that is why an important technical task is to ensure the high precision tracking of the current value of the control parameter. The causes of errors of measurement are analysed in the article. The article analyses the practical schemes of control on operations of round grinding, and situations that may lead to the occurrence of errors from the effects of temperature and the quality of the positioning of the measuring equipment on the control surface.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 3; 86-92
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie danych zawartych w systemie IACS w odniesieniu do systemu ewidencji gruntów i budynków
Comparison of data contained in IACS in the relation to the cadastre system
Autorzy:
Hanus, P.
Powiązania:
https://bibliotekanauki.pl/articles/262244.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
IACS
ewidencja gruntów i budynków
dokładność danych ewidencyjnych
cadastre
cadastre accuracy data
Opis:
W artykule przedstawiono problem wykorzystania danych zawartych w ewidencji gruntów i budynków na potrzeby tworzenia danych niezbędnych do budowania systemu IACS w Polsce. Problem ten stał się szczególnie ważny po wejściu Polski do Unii Europejskiej. Omówiono pokrótce zasady systemu ewidencji gruntów i budynków, a także zakres docelowych danych o gruntach, które stanowią podstawę do określenia wysokości dopłaty bezpośredniej do produkcji rolnej. Stwierdzono, że dane zawarte w ewidencji gruntów i budynków, dotyczące gruntów, są w zupełności wystarczające do celów stawianych przed systemem IACS. Porównując dane zawarte w systemie IACS, należy stwierdzić, że dane dotyczące granic działek ewidencyjnych nie ustępują pod względem dokładności danym pochodzącym z ewidencji gruntów i budynków, a ponadto spełniają stosowne kryteria dokładności przedstawione w odpowiednich przepisach. Są one natomiast bardziej aktualne niż dane pochodzące z ewidencji gruntów i budynków. Należy je zatem wykorzystać w procesie jej modernizacji.
In the paper a problem of using data, contained in cadastre, for the needs of creating data necessary for IACS application in Poland, has been showed. The problem has become especially important after Poland accession to the European Union. Shortly described essential rules of cadastre system and also the ultimate range of grounds data, which are the base for direct determining amount additional payments for agricultural production. It has been stated, that data contained in cadastre are completely sufficient for the aims demanded for IACS system. Comparing data contained in IACS system, one must state, that data referring to the parcel boundaries, do not yield data coming from the cadastre, and moreover they fulfill suitable criteria showed in relevant regulations. However, they are more update then cadastre data. So, one should use them, in cadastre modernization process.
Źródło:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2005, 11, 2; 231-237
1234-6608
Pojawia się w:
Geodezja / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie trajektorii ruchu oraz badanie dokładności pozycjonowania agrorobota
Modelling of movement trajectory and analysis of accuracy of agrorobot positioning
Autorzy:
Boryga, M.
Graboś, A.
Powiązania:
https://bibliotekanauki.pl/articles/286792.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
agrorobot
modelowanie
trajektoria ruchu
dokładność pozycjonowania
modeling
movement trajectories
accuracy of positioning
Opis:
W pracy przedstawiono sposób modelowania trajektorii ruchu w wybranych współrzędnych (kartezjańskich, cylindrycznych i sferycznych) oraz wyniki komputerowej symulacji ruchu agrorobota, którego zespół pozycjonowania posiada trzy stopnie swobody. Badania symulacyjne, dla trzech wybranych torów ruchu chwytaka, przeprowadzono w programie Matlab (Simulink). Przedstawiono rzeczywiste tory ruchu chwytaka agrorobota oraz czasowe przebiegi błędów realizacji zamierzonego toru ruchu.
The study presents a method of modelling of movement trajectory in selected coordinates (Cartesian, cylindrical and spherical) as well as the results of computer simulation of the agrorobot's movement, whose positioning system possesses three levels of freedom. The simulation tests, for three selected movement trajectories of the gripping device, were done in Matlab (Simulink) program. Real movement trajectories of the agrorobot's gripping device were presented, as well as temporal erroneous trajectories.
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 5(80), 5(80); 67-75
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of gender, dominant lower limb and type of target on the velocity of taekwon-do front kick
Autorzy:
Wąsik, J.
Ortenburger, D.
Góra, T.
Shan, G.
Mosler, D.
Wodarski, P.
Michnik, R. A.
Powiązania:
https://bibliotekanauki.pl/articles/306521.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
interakcja
analiza czynnikowa
szybkość
dokładność
interaction
kicking speed
kicking accuracy
factorial analysis
Opis:
Purpose: The current study aimed to quantify the main influences and the interactions (joint effects) of gender, leg and type of target on the biomechanics of front kick quality. Through the quantification, we tried to identify the relevant factors related to the kick accuracy and maximum velocity for coaching practice. Methods: A ten-camera NIR VICON MX40 motion capture system (250 Hz) was used to determine the kicking foot maximum velocity from two well-trained subject groups (8 males and 6 females). Each subject performed both left and right front kicks in a lateral standing position into the air (without a physical target), to a board, to a table tennis ball and to a training shield. The target were set on a height corresponding to a height of solar plexus of each participant. Results: The results showed that all the three factors (gender, leg and type of target) have significant influences on kicking speed ( p < 0.001) and significant interaction (joint effect) was only found between gender and target ( p < 0.001). Further analysis revealed that the males’ kicking maximum velocity was affected more by board, while females’ one was affected by the size of the target. Conclusions: The results would seem to suggest that, for males, kick-to-a-board may be the more effective method for increasing kick quality, compared to other type of target. For females, kick-to-a-small-ball appears to be effective method for increasing kick maximum velocity.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 133-138
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of high-performance PFD-CP for 403MHz CMOS fractional-N frequency synthesizer
Autorzy:
Saleh, S.
Hamdy, G.
Elsemary, H.
Zaki, A.
Powiązania:
https://bibliotekanauki.pl/articles/397720.pdf
Data publikacji:
2017
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
N-PLL
charge pump
current matching
PFD/CP
pompa zasilająca
dokładność prądowa
Opis:
This brief discusses the challenges and employs a novel charge-pump and a PFD/CP linearization technique to improve the performance of a 403MHz fractional-N PLL. Techniques are proposed to improve the linearity of the PLL by forcing the PFD/CP to operate in a linear part of its transfer characteristics, while the charge-pump minimizes the current mismatch between the up and down currents by using feedback. The circuit is designed in 0.13jim CMOS process and consumes a total power of 2.6mW. The simulation results show that the synthesizer has a phase noise of-128dBc/Hz at 1MHz offset.
Źródło:
International Journal of Microelectronics and Computer Science; 2017, 8, 3; 97-100
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zróżnicowanie bogactwa gatunkowego w zależności od wielkości próby i przyjętego wariantu inwentaryzacji
The diversity of species richness, depending on the sample size and the approved variant inventory
Autorzy:
Stepien, E.
Sierdzinski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/880198.pdf
Data publikacji:
2014
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Leśny Zakład Doświadczalny. Centrum Edukacji Przyrodniczo-Leśnej w Rogowie
Tematy:
lesnictwo
zasoby lesne
inwentaryzacja lasu
bogactwo gatunkowe
wielkosc proby
zmiennosc
dokladnosc szacowania
Źródło:
Studia i Materiały Centrum Edukacji Przyrodniczo-Leśnej; 2014, 16, 2A[39]
1509-1414
Pojawia się w:
Studia i Materiały Centrum Edukacji Przyrodniczo-Leśnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobile Laser Scanning accuracy assessment for the purpose of base-map updating
Autorzy:
Fryskowska, A.
Wroblewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/145583.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
skanowanie laserowe
mapa
dokładność danych
mobile laser scanning
base-maps
data accuracy
Opis:
The aim of the research was to analyze the possibility of using mobile laser scanning systems to acquire information for production and/or updating of a basic map and to propose a no-reference index of this accuracy assessment. Point clouds have been analyzed in terms of content of interpretation and geometric potential. For this purpose, the accuracy of point clouds with a georeference assigned to the base map objects was examined. In order to conduct reference measurements, a geodetic network was designed and also additional static laser scanning data has been used. The analysis of mobile laser scanning (MLS) data accuracy was conducted with the use of 395 check points. In the paper, application of the total Error of Position of the base-map Objects acquired with the use of MLS was proposed. Research results were related to reference total station measurements. The resulting error values indicate the possibility to use an MLS point cloud in order to accurately determine coordinates for individual objects for the purposes of standard surveying studies, e.g. for updating some elements of the base map content. Nevertheless, acquiring MLS point clouds with satisfying accuracy not always is possible, unless specific resolution condition is fulfilled. The paper presents results of accuracy evaluation in different classes of base-map elements and objects.
Źródło:
Geodesy and Cartography; 2018, 67, 1; 35-55
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szacowanie dokładności diagnozowania kontrolnego podzespołu silnika okrętowego
Value of control diagnosis accuracy of sub-assembles of the marine diesel engines
Autorzy:
Monieta, J.
Powiązania:
https://bibliotekanauki.pl/articles/327158.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
diagnostyka kontrolna
system wtryskowy
dokładność pomiaru
control diagnostic
injection system
measurement accuracy
Opis:
W referacie przedstawiono metodę określenia błędów systematycznych i niepewności przypadkowych toru pomiarowego diagnostyki kontrolnej na przykładzie wtryskiwacza silnika okrętowego. Uwzględniono w niej wpływ niedokładności pomiaru i regulacji parametrów funkcjonowania systemu wtryskowego na końcowy wynik dokładności symptomu diagnostycznego. Sumaryczne błędy obliczono dla różnych parametrów diagnostycznych w dziedzinie czasu, amplitudy i częstotliwości. Wielkość błędu może być jednym z kryteriów wyboru najbardziej przydatnych parametrów diagnostycznych.
In the paper introduced methods to qualify of systematic errors and accidental uncertainties of measurement line of the control diagnostic on example injector of marine diesel engines. There have been accounted effect inaccuracy measurement and regulation parameters of order of the injection systems on the final results accuracy of diagnostic symptom. Total errors calculated for different diagnostic parameters in domain time, amplitude and frequency. Quantity of errors may be it in one criterions of selection most suitable of diagnostic parameters.
Źródło:
Diagnostyka; 2004, 30, T. 2; 43-46
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strategia pomiaru jako czynnik kształtowania dokładności wyznaczania odchyłek kształtu
Measurement strategy as the precision formation factor of the shape deviation
Autorzy:
Kamieńska-Krzowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/155409.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
strategia pomiaru
dokładność pomiaru
błędy kształtu
measurement strategy
measurement precision
shape errors
Opis:
Nowoczesne systemy pomiarowe spełniają wymagania sterowanego pomiaru i dają możliwość komputerowej analizy uzyskanych wyników jak również opracowania strategii pomiaru przed jego przeprowadzeniem.. Ma to na celu zapewnienie optymalności wyników ze względu na dokładność i niepewność pomiarów. Przeprowadzono analizę wpływu różnych elementów strategii pomiarów na wynik pomiaru odchyłek okrągłości oraz podjęto próbę weryfikacji doświadczalnej. Wyniki badań potwierdziły możliwość kształtowania dokładności wyznaczania odchyłki kształtu poprzez odpowiedni dobór elementów strategii pomiarów.
To the deviation measurements of the machine part shape most frequently modern measuring systems are used. They perform the controllable measurement needs and they give the reliability of computer analysis of measurement results obtained. Hence, very important is elaboration of a measurement strategy before its investigation in such a way, to achieve optimum conditions of guaranted results. One criterion of the optimum condition concerns the precision and uncertainty of measurements. Others concern the application of the best fitting criterion (reference feature), the spacing of measurement points, its quantity, the application of wave filter, the measurement terminal, its diameter, and the influence of measurement mandrels configuration on the result of roundness deviations. The analysis results were confronted with experimental verification. Basing on the tests the possibility of precision formation determination of shape deviation through appropriate selection of measurement strategy elements were confirmed.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 1, 1; 26-27
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania dokładności pozycjonowania pionowego centrum obróbkowego
Assessing the positioning accuracy in vertical milling centres
Autorzy:
Miko, E.
Jarema, M.
Powiązania:
https://bibliotekanauki.pl/articles/155415.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
obrabiarka CNC
dokładność pozycjonowania
powtarzalność pozycjonowania
CNC machine
positioning accuracy
positioning repeatability
Opis:
Przeprowadzono analizę układu odczytu pozycji w osiach X, Y i Z pionowego centrum obróbkowego. W pomiarach wykorzystano płytki wzorcowe, jako wzorzec długości oraz układ rejestrujący składający się ze sterownika obrabiarki oraz sondy pomiarowej stanowiącej wyposażenie dodatkowe. Obliczenia przeprowadzono zgodnie z PN -ISO 230-2. Stwierdzono, że w przypadku pomiarów dokładności i powtarzalności pozycjonowania testowana obrabiarka spełnia parametry deklarowane przez producenta a nawet znacznie je przewyższa. Bardzo dobre wyniki osiągnięto podczas badania powtarzalności pozycjonowania. Tak wysoki poziom powtarzalności (zaobserwowany 0,0016mm, deklarowany 0,005mm) autorzy tłumaczą tym, że testowana obrabiarka jest maszyną praktycznie nową. Badania przeprowadzono po 6 miesiącach używania obrabiarki w warunkach laboratoryjnych. Zastosowana metoda badawcza może być wykorzystywana do przeprowadzania okresowych kontroli stanu obrabiarek CNC pod kątem dokładności i powtarzalności pozycjonowania.
The paper analyzes the accuracy of a readout system measuring the positions of a vertical milling centre along the X-, Y- and Z- axes. The tests were conducted using gauge blocks as length standards and a measuring system including a machine tool controller and an optional touch probe. The calculations were performed in accordance with the PN -ISO 230-2 standard. With regard to the accuracy and repeatability of positioning, the vertical milling centre meets or even exceeds the parameters set by the producer. Very good results were achieved particularly during the repeatability tests. The high level of repeatability of up to 0.0016mm, which is much more than the declared value 0.005, is probably due to the fact that the milling centre is new. The tests were conducted after six months of use under laboratory conditions. The method applied during the tests is suitable for periodic inspection of CNC machine tools when checking the accuracy and repeatability of positioning.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 1, 1; 63-65
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przydatność algorytmów podpikselowej detekcji cech w wybranych zagadnieniach fotogrametrycznych
The usefulness of sub-pixel feature extraction algorithms in selected photogrammetric cases
Autorzy:
Mikrut, S.
Powiązania:
https://bibliotekanauki.pl/articles/130666.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
fotogrametria cyfrowa
dokładność podpikselowa
detekcja cech
digital photogrammetry
subpixel precision
feature extraction
Opis:
Celem artykułu było zaprezentowanie wyników badań nad przydatnością algorytmów podpikselowej dokładności detekcji cech w wybranych zagadnieniach fotogrametrycznych. Pojęcie detekcji cech obejmuje wszystkie metody mające na celu wydobycie z obrazu cyfrowego właściwości takich jak: pojedyncze obiekty, krawędzie, geometryczne środki obiektów czy inne. W niniejszej publikacji autor skupił się na zagadnieniu detekcji cech prowadzących do zdefiniowania krawędzi wybranych obiektów celem ich lokalizacji z bardzo wysoką precyzją. Do tego celu wykorzystano autorskie algorytmy bazujące na wykrywaniu krawędzi z podpikselową dokładnością w oparciu o badanie pierwszej i drugiej pochodnej obrazu cyfrowego. Znajdowane z taką precyzją punkty na odpowiednim przekroju krawędzi (wiersz lub kolumna obrazu cyfrowego) są następnie aproksymowane wybraną funkcją matematyczną (w najprostszym przypadku będzie to linia prosta) i w efekcie końcowym dochodzimy do postaci wektorowej krawędzi. Algorytmy te zostały przetestowane w wielu pracach fotogrametrycznych. Niniejsza publikacja przybliża ich wykorzystanie w jednym z zadań fotogrametrii inżynierskiej jakim jest badanie imperfekcji kształtu wysmukłych budowli. Opracowane procedury pozwalające na wykonanie automatycznych pomiarów na obrazie cyfrowym, dały podstawy na zaprojektowania systemu, który docelowo miał być zintegrowany z notebookiem, aby umożliwić prace w czasie rzeczywistym. Algorytmy do badania imperfekcji kształtu na obrazie cyfrowym bazują na detekcji pojedynczych punktów przekroi krawędziowych, a następnie na wpasowaniu linii prostej reprezentującej badany kształt obiektu. Algorytmy zostały oprogramowanie i zaimplementowane do systemu powstającego w ramach projektu badawczego.
The purpose of the article was to present the results of research on the usefulness of algorithms of sub-pixel accuracy of feature extraction in selected photogrammetric cases. The concept of feature extraction includes all methods aiming at the extraction from a digital image of such selected properties as single objects, edges, geometric centres of objects, or other properties. In this publication, the author focuses on the problem of feature extraction, leading to the definition of edges of selected objects in order to be able to locate them with a very high precision. For this purpose, own algorithms based on edge detection with a sub-pixel accuracy based on the examination of the first and the second derivatives of the digital image were applied. Points, which have been found with such a precision at the appropriate section of the edge (row or column of the digital image) are later approximated, using a selected mathematical function (in the simplest case this will be a straight line), and finally, a vector form of the edge is obtained. Those algorithms have been tested in many photogrammetric works. This publication brings closer their utilization in one of the photogrammetric engineering tasks, namely the investigation of the imperfection of shape of lofty buildings and structures. The developed procedures for the implementation of automated measurements on a digital image have helped to design a system that eventually was to be integrated with a notebook, allowing for work to be performed in a real time. Algorithms for testing the shape imperfection on a digital image are based on detecting single points of edge sections, and then fitting a straight line, which represents the shape of the object under investigation. The software and algorithms have been implemented to the system being created under a research project. The whole is written in C + +.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2009, 19; 299-308
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of changes in the geometry of the tooth surface of the pinion bevel gear on the kinematic accuracy of pair mesh
Autorzy:
Płocicia, M.
Pisula, J.
Powiązania:
https://bibliotekanauki.pl/articles/386490.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
bevel gears
Gleason
kinematic accuracy
przekładnia stożkowa
przekładnia stożkowa Gleasona
dokładność kinematyczna
Opis:
The paper describes the possibilities of bevel gears kinematics design on the basis of the motion graph and improving modifica-tions to cut the pinion teeth flanks. The result is the ability to increase the accuracy of the kinematic transmission. The issue of changing the geometry of the pinion gear is considered in respect of a gear intended for the use in aviation, which requires the cooperation of high quality meshing. The basic geometric features that have been modified include the profile angle, the angle of tooth line, crowning trans-verse and longitudinal and lateral surface twist angle of the tooth. The modification of each of the selected geometrical parameters has had a different effect on the chart of transmission. It has been shown that the effect of the intended changes in the geometry of the pinion may reduce the deviation of motion delays gear and an improve the gear transmission chart.
Źródło:
Acta Mechanica et Automatica; 2014, 8, 2; 95-98
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność obliczania pola powierzchni ze współrzędnych płaskich prostokątnych
Accuracy of calculation of the areas from plane coordinates
Autorzy:
Doskocz, A.
Powiązania:
https://bibliotekanauki.pl/articles/341243.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Przyrodniczy we Wrocławiu
Tematy:
obiekty katastralne
dokładność obliczania pola powierzchni
cadastral objects
accuracy of area calculation
Opis:
Współczesne mapy wielkoskalowe opracowywane są w systemach informacyjnych, jednakże cyfrowa forma opracowania bynajmniej nie zmienia oczekiwań zdefiniowanych niegdyś w przypadku mapy analogowej. W realizacji procesu obsługi inwestycji typowymi informacjami pozyskiwanymi z map wielkoskalowych są odległości i pola powierzchni. W niniejszej pracy przedstawiono analizę dokładności obliczenia pola powierzchni wieloboków ze współrzędnych (X, Y) wierzchołków z uwzględnieniem błędów średnich (mX, mY) ich wyznaczenia. W wyniku analiz wykazano także wpływ średniego błędu położenia punktów granicznych na dokładność analitycznego wyznaczenia pola powierzchni działki ewidencyjnej. Ponadto, podano nową formułę na dopuszczalną różnicę dwukrotnego analitycznego wyznaczenia pola powierzchni.
Nowadays large-scale maps are making in information systems but digital map data are not still free from traditional tasks of analogue map. The typical tasks of large-scale map are distances and areas determining, for example to realize of investment project. The paper presents analysis of accuracy in calculation of the area of a polygon from coordinates (X, Y) of its vertexes taking their mean errors (mX, mY) under consideration. Results of analysis of influence root mean square error of a position of the boundary points on accuracy analytical determination of the area of a parcel are also given in the paper. Besides, admissible divergence in twice determining areas is calculated with the proposed new formula.
Źródło:
Acta Scientiarum Polonorum. Geodesia et Descriptio Terrarum; 2011, 10, 3; 29-43
1644-0668
Pojawia się w:
Acta Scientiarum Polonorum. Geodesia et Descriptio Terrarum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności wysokościowej danych lotniczego skaningu laserowego systemu ISOK na obszarze doliny rzeki Widawy
Accuracy assessment of the height component of the airborne laser scanning data collected in the ISOK system for the Widawa river valley
Autorzy:
Pawłuszek, K.
Ziaja, M.
Borkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/341507.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Przyrodniczy we Wrocławiu
Tematy:
lotniczy skaning laserowy
NMT
ISOK
dokładność
airborne laser scanning (ALS)
DTM
accuracy
Opis:
Głównym obszarem zastosowań lotniczego skaningu laserowego (ALS) jest budowa wysokorozdzielczych precyzyjnych numerycznych modeli terenu (NMT). W Polsce, na potrzeby budowy systemu osłony przed nadzwyczajnymi zagrożeniami, zeskanowano niemal całą powierzchnię kraju. Jakość i dokładność danych skaningu były przedmiotem kontroli na etapie ich pozyskiwania. W niniejszej pracy dane te poddano ocenie dokładności wysokościowej według odmiennej metodyki. Dokonano oceny dokładności wewnętrznej polegającej na wpasowaniu, metodą najmniejszych kwadratów, płaszczyzny w zbiór danych repezentujących płaską powierzchnię, np. połać dachu, oraz oszacowaniu błędu średniego na podstawie odchyłek danych ALS od tej powierzchni. Testy wykonano dla 36 płaszczyznowych powierzchni reprezentujących dachy, drogi, łąki oraz pola orne. W przypadku powierzchni antropogenicznych otrzymany błąd średni kształtuje się na poziomie zbliżonym do dokładności pomiaru odległości przez system skanujący i wynosi od 2 do 4 cm. Dla powierzchni naturalnych, o dużej szorstkości błąd ten rośnie do wartości od 3 do 20 cm. Ocenę dokładności zewnętrznej (absolutnej) wykonano na podstawie porównania wysokości danych ALS z wysokościami punktów referencyjnych pomierzonych technikami geodezyjnymi. Oszacowanie dokładności przeprowadzono w przypadku trzech klas pokrycia terenu (pola i łąki, drogi, lasy) oraz czterech obszarów testowych, zlokalizowanych na obszarze doliny rzeki Widawy. Ocenę dokładności wykonano na potrzeby modelowania hydrologicznego. Dokładność absolutna waha się w poszczególnych typach pokrycia od niewiele ponad 10 cm w przypadku dróg do ponad dwukrotnie większej wartości na terenach leśnych.
The main application of airborne laser scanning (ALS) technology is the data collection for creating high quality digital elevation models (DEM). In Poland, almost entire area of the country has been scanned for the implementation phase of extraordinary hazards (mostly water hazards) protection system (ISOK). The quality of acquired data was a subject of inspection at the acquisition time. In this study, an alternative methodology was applied to evaluate the height component accuracy of the ALS data. For the inner accuracy evaluation (data consistency), subsets of the point cloud representing flat surfaces (e.g. roofs) were used. This data was approximated by a plane using least squares method. Based on residuals between approximated plane and the ALS data a mean square error was calculated. Numerical tests were executed for 36 planes representing roofs, roads, meadows and arable fields. For the anthropogenic areas the estimated mean square error is similar to the accuracy of distance measurement by a scanning system and ranges from two to four cm. In the case of natural surfaces that are characterized by high roughness, the error increases to a value of three to twenty cm. In order to assess the external (absolute) accuracy of the ALS data, heights of the reference points measured by geodetic techniques were compared with the heights of corresponding (neighboring) ALS points. The accuracy assessment was carried out for three classes of the land use (arable fields and meadows, roads, forests) and four test areas, located in the area of Widawa River Valley. The absolute accuracy varies for different types of land use from slightly more than ten cm for roads to more than double the value for forests.
Źródło:
Acta Scientiarum Polonorum. Geodesia et Descriptio Terrarum; 2014, 13, 3-4; 27-37
1644-0668
Pojawia się w:
Acta Scientiarum Polonorum. Geodesia et Descriptio Terrarum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The method of high accuracy at dynamically tuned gyroscope
Metoda wysokiej dokładności w żyroskopach z regulacją
Autorzy:
Lushnikov, E. M.
Powiązania:
https://bibliotekanauki.pl/articles/359449.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
dokładność
parametry żyroskopu
charakterystyka rezonansu
accuracy
gyroscope's parameters
characteristics of the resonance
Opis:
The method of high accuracy for dynamically tuned gyroscope is presented. The mathematical description and calculation of the gyroscope's parameters which have coefficient of integrating 6.9 are described. The characteristics of the resonance depending of generalized parameter and influence of balance variation on accuracy were analyzed. The result of experiment is according to theory at condition of experiment in vacuum chamber.
W artykule zaprezentowano metodę osiągania wysokiej dokładności w żyroskopach z regulacją dynamiczną. Podano opis matematyczny i obliczono parametry żyroskopu o zwiększonej dokładności do 6,9 raza. Przeanalizawano charakterystyki rezonansu w zależności od przyjętego parametru i wpływ wariacji balansu na dokładność. Wyniki badań eksperymentalnych w komorze próżniowej są zgodne z teoretycznymi.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 20 (92); 75-81
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapewnienie dokładności pomiarowej w systemie zarządzania jakością
Assurance of measurement capability in quality management systems
Autorzy:
Raczka, M.
Rewilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/269798.pdf
Data publikacji:
2010
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
dokładność pomiarowa
zarządzanie jakością
systemy pomiarowe
measurement accuracy
quality management
measurement system
Opis:
W artykule przedstawiono systemowe podejście do zagadnień prowadzenia pomiarów. Przedstawiono wymagania dotyczące nadzorowania wyposażenia pomiarowego w normach jakościowych ISO 9001 i ISO 17025 oraz wytyczne norm ISO 10012, a także metodyki stosowane w systemie zarządzania w branży motoryzacyjnej. Omówiono zasady nadzorowania wyposażenia pomiarowego oraz analizowania systemów pomiarowych.
The paper presents a systematic approach to issues of measurement and the requirements for monitoring measuring equipment according to quality standards ISO 9001, ISO 17025 and ISO 10012, as well as the methodology used in the Management System Analysis in the automotive industry. Also discussed are the procedures, requirements and management problems related to MSA, including necessary resources and planning issues.
Źródło:
Inżynieria Maszyn; 2010, R. 15, z. 3; 69-81
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody oceny dokładności technologicznej precyzyjnych tokarek CNC
Methods of technological accuracy evaluation of precision CNC lathes
Autorzy:
Kowalski, T.
Jastrzębski, , R.
Powiązania:
https://bibliotekanauki.pl/articles/270127.pdf
Data publikacji:
2012
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
tokarka NC
obróbka
dokładność
koncentracja
pomiary
CNC lathe
machining
accuracy
concentration
measurements
Opis:
Wybrano i scharakteryzowano metody badań dostosowane do oceny błędów ruchów technologicznych. Są to: metoda oceny zmian położenia osi obrotowej, metoda pomiaru błędów nastawionych prędkości obrotowych, test interpolacji kołowej. Wybór, dokładność i parametry tych metod dostosowano do wybranych zadań obróbkowych. Zaproponowano ocenę wpływu konstrukcji maszyny na dokładność obrobionych przedmiotów. Postawiono pytanie; czy przyczyną błędów obróbki przedmiotów są błędy obrotu przedmiotu, błędy obrotu narzędzia, czy błędy nastawionego posuwu osi X, Z lub ruchu interpolowanego i czy wynikają one z właściwości konstrukcyjnych tokarki (odwzorowanie), czy z błędów regulacji ruchów technologicznych (głównie nadążania).
Selected and described are methods adapted for evaluation of technological motion errors. These are: method of evaluation of rotating axes position change, method of measurement of rotational speed error, circular interpolation test. Selection, accuracy and parameters of these methods have been adapted for selected machining tasks. The question has been raised: if the cause of machining inaccuracies is error of workpiece rotation, error of tool rotation, error of set feed rate of X or Z axes or error interpolation motion and if the errors are result of properties of a lathe (reproduction) or of erroneous technological motions (mainly following error).
Źródło:
Inżynieria Maszyn; 2012, R. 17, z. 2; 31-37
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie obserwacji GLONASS w metodzie PPP w eksperymencie lotniczym w Mielcu
Applied GLONASS observations in PPP method in airborne test in Mielec
Autorzy:
Krasuski, K.
Jafernik, H.
Powiązania:
https://bibliotekanauki.pl/articles/407872.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
GLONASS
metoda PPP
odchylenie standardowe
dokładność
MRSE
PPP method
standard deviation
accuracy
Opis:
Artykuł przedstawia rezultaty badań dotyczących wyznaczenia pozycji statku powietrznego Cessna 172 z zastosowaniem metody PPP dla obserwacji kodowo-fazowych w systemie GLONASS. Współrzędne samolotu zostały wyznaczone z interwałem 1 sekunda w programie CSRS-PPP oraz magicPPP. W artykule przedstawiono i opisano algorytm odtworzenia pozycji statku powietrznego dla metody PPP. Eksperyment lotniczy został wykonany w dniu 07.09.2011 na lotnisku w Mielcu w celu sprawdzenia dokładności pozycjonowania statku powietrznego w trybie kinematycznym. Wstępna dokładność współrzędnych samolotu została wyznaczona na poziomie 0,1 m z użyciem programów CSRS-PPP i magicPPP.
Article presents research results concerning to determination Cessna 172 plane position using PPP method for code and phase observations in GLONASS system. The aircraft’s coordinates were estimated in CSRS-PPP and magicPPP softwares with interval 1 second. The algorithm of PPP method for recovery aircraft’s position was described in details in the article. The airborne test was realized for checked positioning accuracy of the aircraft in kinematic mode on 07.09.2011 in Mielec airport. The preliminary results of accuracy of aircraft’s coordinates was obtained on the level 0,1 m using CSRS-PPP and magicPPP softwares.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 2; 83-88
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza aktualnych dokładności i precyzji ręcznego odbiornika GPS z sygnałem EGNOS
Analysis of current accuracy and precision of the manual GPS receiver with EGNOS signal
Autorzy:
Siejka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/61032.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
system GPS
odbiorniki GPS
odbiorniki reczne
system EGNOS
bledy pomiarowe
dokladnosc pomiaru
Opis:
W pracy przedstawiono wyniki pomiarów testowych dokonanych przy pomocy ręcznego odbiornika sygnałów GPS (Global Positioning System), przystosowanego do odbioru sygnału korygującego EGNOS (European Geostationary Navigation Overlay Service), który teoretycznie ma obejmował swoim zasięgiem Europę i północną część Afryki. Wiadomym jest jednak, że Europa srodkowa i Wschodnia znajduje się na granicy zasięgu EGNOS i niektóre obszary Polski mają ograniczony dostęp do sygnałów tego systemu. Pomiary testowe przeprowadzono na wybranych punktach stacjonarnych przy pomocy odbiornika firmy Garmin GPSMAP 62s wyposażonego w aktywną antenę zewnętrzną MAZO GPS. Podczas wykonywanych pomiarów rejestrowano współrzędne przestrzenne, ich wiarygodność, liczbę odbieranych satelitów, czas pomiaru, dostępność sygnału EGNOS. Wnioski z przeprowadzonych badań wskazują na szerokie możliwości stosowania ręcznych odbiorników w pomiarach głównie na potrzeby systemów informacji przestrzennej i zadań pomiarowych w inżynierii środowiska, ale wiarygodność wyników zależy od wielu czynników i zachowania określonego reżimu pomiarowego.
The paper presents results of test measurements conducted with the use of a manual receiver of GPS (Global Positioning System) signals adjusted to the reception of EGNOS (European Geostationary Navigation Overlay Service) correction signal which is theoretically to cover Europe and southern part of Africa with its range. However, it is known that Central and Eastern Europe lies on the border of EGNOS range and some parts of Poland have limited access to signals from this system. Test measurements were conducted on selected stationary points with the use of the receiver produced by Garmin GPSMAP 62s, equipped with MAZO GPS active outdoor aerial. During the measurements, spatial coordinates, their reliability, number of satellites received, time of measurement, accessibility of EGNOS signals were registered. Results of the conducted tests indicate broad possibilities of using manual receivers in measurements mainly for the needs of spatial measurement systems but not only. Yet the reliability of results depends on many factors and on keeping a specific measurement regime.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2012, 1/II
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Realizacja algorytmu szybkiego pozycjonowania na platformie PLC
Implementation of a fast positioning algorithm at the PLC platform
Autorzy:
Cechowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/274807.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pozycjonowanie
sterownik PLC
estymacja
dokładność
sterowalność
positioning
PLC controller
estimate
accuracy
controllability
Opis:
Precyzyjny pomiar położenia poruszającego się obiektu może być trudny do zrealizowania w systemach sterowania wyposażonych w sterowniki PLC ze względu na czas cyklu sterownika. Z drugiej strony, wykorzystanie funkcji liczników sprzętowych nie zawsze umożliwia pełną kontrolę procesu. W artykule przedstawiono jeden ze sposobów realizacji procesu pozycjonowania z wykorzystaniem sterownika PLC wyposażonego w licznik sprzętowy.
Precise position estimation of a moving object can be difficult in a PLC-based control system because of the time lag caused by the non-zero PLC cycle time. On the other hand, using the functions of the hardware counters could compromise system security. The article presents an approach where good accuracy was achieved using the estimation procedures in a standard PLC equipped with an embedded hardware counter.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 10; 54-57
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Teoretyczna dokładność statystycznej metody reprezentacyjnej pomiaru miąższości obrębu leśnego
Growing stock assessment trough stratified sampling – accuracy of the method at strata and forest division level
Autorzy:
Jablonski, M.
Powiązania:
https://bibliotekanauki.pl/articles/45647.pdf
Data publikacji:
2011
Wydawca:
Instytut Badawczy Leśnictwa
Tematy:
lesnictwo
obreby lesne
miazszosc drzewostanow
zasoby drzewne
pomiary
metody statystyczne
metoda reprezentacyjna
dokladnosc
Źródło:
Leśne Prace Badawcze; 2011, 72, 2
1732-9442
2082-8926
Pojawia się w:
Leśne Prace Badawcze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dokładność statystycznej metody reprezentacyjnej a zmiany wielkości zasobów drzewnych w kolejnych rewizjach urządzania lasu
A comparison of two growing stock assessments by stratified sampling - how does accuracy of inventory affect our interpretation of the results
Autorzy:
Jablonski, M.
Powiązania:
https://bibliotekanauki.pl/articles/46349.pdf
Data publikacji:
2013
Wydawca:
Instytut Badawczy Leśnictwa
Tematy:
lesnictwo
urzadzanie lasu
zasobnosc drzewostanu
zasoby drzewne
szacowanie
metody statystyczne
metoda reprezentacyjna
dokladnosc
Źródło:
Leśne Prace Badawcze; 2013, 74, 1
1732-9442
2082-8926
Pojawia się w:
Leśne Prace Badawcze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laser particle size analysis - the influence of density and particle shape on measurement results
Laserowa analiza uziarnienia - wpływ gęstości i kształtu ziaren na wyniki pomiarów
Autorzy:
Krawczykowski, D.
Krawczykowska, A.
Trybalski, K.
Powiązania:
https://bibliotekanauki.pl/articles/216976.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
laserowe analizy granulometryczne
dokładność analiz granulometrycznych
laser granulometric analysis
accuracy of granulometric analysis
Opis:
The paper concerns the accuracy of determining particle size distributions of the fine-grained materials by means of laser diffraction method. Selection of measuring method for determination of materials granulation depends on various properties of the sample, but mainly on the range of particle size in the sample. It must be taken into consideration that each of the measurement methods inherently generate different information about particle size distribution. The applied measurement method generates the main impact on the results of research because it uses various material properties, like: geometric properties, density or type of the surface (porosity). Influence of density and particle shape on the results of measurements by laser diffraction was studied in the paper. This method becomes a standard for measuring particle size of mineral powders. Analysis of raw materials particle size distribution was performed using a laser particle-meter Analysette 22. Investigations included measurements of particle size of raw materials characterized by various densities (coal, porphyry, barite) and the shape of the particles (copper shale ore, fly ash from coal combustion). The density of raw materials was determined by helium pycnometer, while the particle shape was expressed by coefficient which was calculated on the basis of particles geometric parameters. Geometry of the grains was measured using an optical microscope with a digital record of images by means of image analysis method. The accuracy of laser granulometric analyzes was expressed by variation coefficient of narrow particle fractions contents. Results of analyzes confirmed that the laser granulometric analysis provides accurate information about the finest particle size distribution. No significant effect of the material density on the accuracy of granulometric analysis was observed. Effect of particle shape of the tested materials caused more stable values of the variation coefficient for particles of more spherical shape what is related to the applied method of laser measurement. The accuracy of laser granulometric analyzes varies dependably on the measured particle size range of particles. The most accurate analyzed materials are these ones being the part of narrow particle fractions.
Artykuł dotyczy dokładności określania składów ziarnowych materiałów drobnoziarnistych metodą laserową. Wybór metody pomiarowej do określenia składu ziarnowego materiałów uziarnionych zależy od różnych właściwości reprezentującej go próbki, głównie jednak od zakresu wielkości ziaren znajdujących się w badanej próbce. Należy jednak zdawać sobie sprawę, że każda z metod pomiarowych generuje z założenia różną informację o rozkładzie wielkości cząstek. Na wyniki oznaczeń główny wpływ ma bowiem stosowana metoda pomiaru, wykorzystująca różne właściwości materiałów: np. właściwości geometryczne, gęstość, charakter powierzchni (porowatość) itp. Badano więc wpływ gęstości oraz kształtu cząstek na wyniki pomiarów metodą dyfrakcji laserowej, która to metoda staje się standardową w pomiarach uziarnienia proszków mineralnych. Analizy składów ziarnowych surowców wykonano przy użyciu laserowego granulometru Analysette 22 firmy Fritsch. Badania obejmowały pomiary uziarnienia surowców różniących się gęstością (węgiel kamienny, porfir, baryt) oraz kształtem ziaren (łupkowa ruda miedzi, popiół lotny ze spalania węgla). Gęstość surowców określono metodą piknometrii helowej, natomiast kształt ziaren wyrażono współczynnikiem kształtu obliczonym na podstawie wielkości geometrycznych cząstek. Geometrię ziaren badano przy użyciu mikroskopu optycznego z cyfrowym zapisem zdjęć, które poddano komputerowej analizie obrazu. Dokładność laserowych analiz granulometrycznych wyrażono współczynnikiem zmienności udziału wąskich klas ziarnowych. Wyniki analiz potwierdziły, że laserowa analiza granulometryczna dostarcza dokładnych informacji o rozkładzie wielkości cząstek najdrobniejszych. Nie zaobserwowano istotnego wpływu gęstości materiału na dokładność analiz granulometrycznych. Wpływ kształtu ziaren badanych materiałów zaznaczył się stabilniejszymi wartościami współczynnika zmienności dla cząstek o kształcie bardziej sferycznym, co ma związek z zastosowaną laserową metodą pomiaru. Dokładność laserowych analiz granulometrycznych różni się w zależności od zakresu uziarnienia mierzonych cząstek, najdokładniej analizowane są materiały w wąskich klasach ziarnowych.
Źródło:
Gospodarka Surowcami Mineralnymi; 2012, 28, 4; 101-112
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyznaczania zalecanego wskaźnika sztywności statycznej tokarek karuzelowych
The method for determining the recommended static stiffness indicator for vertical turning lathes
Autorzy:
Śliwka, J.
Powiązania:
https://bibliotekanauki.pl/articles/269863.pdf
Data publikacji:
2016
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
vertical turning lathes
machining accuracy
static
stiffness
obrabiarka ciężka
dokładność obróbki
wskaźnik
sztywność
Opis:
W artykule omówiono metodę określania zalecanego wskaźnika sztywności statycznej dedykowaną dla tokarek karuzelowych. Zaproponowana metoda bazuje na analizie dokładności obróbki. Uzyskane wartości zalecanego wskaźniki sztywności zestawione zostały z wynikami badań przeprowadzonymi na wybranej grupie tokarek karuzelowych.
The article discusses the method for determining the recommended indicator of static stiffness dedicated to vertical turning lathe. The proposed method is based on analysis of the machining accuracy. The resulting value of the recommended indicators stiffness were summarized the results of tests carried out on a selected group of vertical turning lathes.
Źródło:
Inżynieria Maszyn; 2016, R. 21, z. 1; 69-79
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pozycjonowanie siłownika roboczego układu elektrohydraulicznego przy zróżnicowanych obciążeniach masowych
The effect of the load mass change on the character of the movement of the electrohydraulic drive system
Autorzy:
Kollek, W.
Siwulski, T.
Stachowiak, Z.
Powiązania:
https://bibliotekanauki.pl/articles/270025.pdf
Data publikacji:
2012
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
hydrostatyczny układ napędowy
dokładność pozycjonowania
masa obciążająca
hydrostatic drive
positioning accuracy
load mass
Opis:
W artykule przedstawiono wyniki badań wpływu masy obciążenia na przebieg ruchu hydrostatycznego układu napędu z systemem automatycznej regulacji. Wartością zadaną układu regulacji było żądane położenie końcowe siłownika. Badania były prowadzone zarówno na obiekcie rzeczywistym, do tego celu wykorzystano symulator napędu liniowego Hydropax Zy25, jak i z wykorzystaniem modelu numerycznego zweryfikowanego w oparciu o wyniki badań laboratoryjnych. Otrzymane wyniki wskazują, że wpływ zmian masy obciążenia, a co za tym idzie sił dynamicznych działających na układ sterowany za pomocą systemu automatycznej regulacji, w badanej konfiguracji jest nieznaczny. Wyniki wskazują również, że w początkowej fazie dominującą rolę w kształtowaniu charakteru ruchu badanego układu napędowego ma moc generowana przez pompę oraz nastawa zaworu przelewowego. W drugiej fazie ruchu, gdy prędkość układu zaczyna się zmniejszać, przebieg ruchu jest właściwie niezależny od masy obciążenia i determinowany jest stopniem otwarcia serwozaworu.
The article presents the study results of the influence of the load mass on the course of the working system movement with a hydrostatic drive system and the feedback system. Studies have been conducted both on the real object, had been used the linear drive simulator Hydropax Zy25 and the numerical model. The numerical model has been successfully verified based on the laboratory test results. The results show that the effect of the change load mass, and the dynamic forces acting on the working system with the hydrostatic drive using feedback control systems in tested configuration is the slightly. The results also indicate that the dominant role in shaping the character of the movement of the tested working system, in the initial phase, has the power generated by the pump and relief valve setting. This follows from the fact that when changing the load mass differences in flow rates registered both on the actuator supply line and the overflow valve line are visible in the initial phase of movement, when the mass increase the speed. In this phase the mass generated a motion dynamic forces, which take effect on the working system. After the increased the speed of the mass of the further course of movement, associated with gradual deceleration to a stop, regardless of mass loading is similar, and is controlled by the feedback control system. Thus, during deceleration the size of servo valve opening affects significantly the nature of motion, and the power of the pump has no effect in this stage of the movement.
Źródło:
Inżynieria Maszyn; 2012, R. 17, z. 4; 16-22
1426-708X
Pojawia się w:
Inżynieria Maszyn
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies