Tytuł:
Optimizing the values of the selected scalar quantities in designing a condenser of marine steam turbine according to the adopted criteria in this designing
Autorzy:
Łukaszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/243452.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
heat exchangers
optimization of condenser
designing of condenser
Opis:
The paper presents designing activities concerning the rating of the values of scalar quantities optimized in accordance with the accepted criteria in designing a condenser of marine steam turbine, which result from the forecasted characteristic, most frequently occurring set points of steam turbine power appearing during the operation of a sea ship. It refers to the method of designing heat exchangers contained in the paper [1] and to the issues raised in the publication [2]. The paper also presents exemplary computational results of the above-mentioned optimized scalar quantities, which refer to designing a shell and tube condenser of marine steam turbine. It was assumed in the paper that the values of mass the mass flow rate of the steam: one p m , 0.75 p m , 0.5 p m , which result from the assumed characteristic set points of marine steam turbine, which occur during the operation of a sea ship. Then, the selected designing activities referring to the above-mentioned optimization were exemplified. On the basis of the computational results, it was shown that the appropriate division of heat exchange area into the definite numbers of condensers, which results from the operation of steam turbine of a definite sea ship, increases operation effectiveness of these condensers in relation to one marine steam turbine condenser. This is a result of optimal values retention: velocity of cooling water of the definite condenser or condensers and temperature of this water on the output of this condenser or condensers during characteristic set points in the operation conditions defined in designing. Next, economic advantages were pointed out, which resulted from the described in the paper, technical solution. These advantages constitute the designing criterion that must be taken into consideration while making a decision about the division of heat exchange area into the definite number of condensers of marine steam turbine. Finally, the conclusions resulting from the paper’s contents are presented.
Źródło:
Journal of KONES; 2014, 21, 2; 193-199
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining steam condensation pressure in a power plant condenser in off-design conditions
Autorzy:
Laskowski, Rafał
Smyk, Adam
Ruciński, Adam
Szymczyk, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1954999.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power plant
steam condenser
condenser model
steam condensation
pressure
reference parameters
steam condenser effectiveness
Opis:
The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena konstrukcji skraplacza na podstawie minimum strumienia generacji entropii
The condenser design assessment on the basis of the minimum entropy generation
Autorzy:
Laskowski, R.
Rusowicz, A.
Grzebielec, A.
Jaworski, M.
Powiązania:
https://bibliotekanauki.pl/articles/271317.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
skraplacz
minimum generacji strumienia entropii
ocena konstrukcji skraplacza
condenser
minimum entropy generation
condenser design assessment
Opis:
W skraplaczach energetycznych generowane są jedne z największych strat strumienia entropii w instalacji energetycznej. Celowe jest obniżanie tej straty, aby uzyskać poprawę całkowitej sprawności instalacji. W artykule podano warunek dla minimum generacji strumienia entropii, z którego wynika, że minimum to jest osiągnięte, gdy podgrzew wody w rurkach skraplacza ma równomierny rozkład (przyjmuje taką samą wartość dla wszystkich rurek). Poprawność tego warunku sprawdzono na podstawie danych uzyskanych z symulatora 2D skraplacza dla jednego z krajowych bloków o mocy 50 MW. Na podstawie otrzymanych z symulatora przyrostów temperatur oraz odpowiadających im ciśnień pary dla 30 rurek dokonano oceny poprawności konstrukcji skraplacza.
The losses in power plants condensers are some of the biggest losses in the entropy generation in whole power plant system. It is advisable to decrease the loss for improving the overall efficiency of the system. The article presents the condition for the minimum entropy generation, which states that the minimum is achieved when the heating of the water in the tubes of the condenser has a uniform distribution (takes the same value for all tubes). The correctness of this condition was verified on the basis of data obtained from the 2D condenser simulator for one of the national units with a 50 MW electric capacity. On the basis of the simulator increases temperatures and steam pressures corresponding to 30 tubes assesses the correctness of the construction of the condenser.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 2; 76-84
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mitigation of voltage flicker by superconducting synchronous Condenser (SUPERVAR)
Autorzy:
Tsai, S. S.
Liu, Y.
Ingram, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/262647.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
superconductivity
synchronous condenser
voltage flicker
power quality
Opis:
Voltage flicker caused by the electric arc furnace (EAF) and the mitigation using the superconducting synchronous condenser (SuperVAR) by the American Superconductor Corp. are considered in this paper. The modeling of EAF, SuperVAR and the system used are discussed. Fast reactive power support to reduce voltage flicker problem by an EAF is desirable. The voltage fluctuation amplitude is used as an index to evaluate the effectiveness of SuperVAR for two different MVar levels. At the PCC (point of common coupling) bus, the application of the SuperVAR can improve the voltage flicker by 6% and 19% by applying DC1A type and AC4A type exciter to the SuperVAR. With an DC1A type exciter, the SuperVAR can output only between +1 and -2 MVAR and with an AC4A type exciter the SuperVAR can provide its full rated power (8MVAR) to the system, making the voltage flicker a less severe.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 39-44
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Entropy generation in a condenser and related correlations
Autorzy:
Laskowski, R.
Jaworski, M.
Smyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/240683.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam condenser
entropy generation
kondensator pary
generowanie entropii
Opis:
The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Źródło:
Archives of Thermodynamics; 2015, 36, 2; 27-48
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Equality cases for condenser capacity inequalities under symmetrization
Autorzy:
Betsakos, Dimitrios
Pouliasis, Stamatis
Powiązania:
https://bibliotekanauki.pl/articles/747114.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
Steiner symmetrization
Schwarz symmetrization
polarization
condenser
capacity
Green function
Opis:
It is well known that certain transformations decrease the capacity of a condenser. We prove equality statements for the condenser capacity inequalities under symmetrization and polarization without connectivity restrictions on the condenser and without regularity assumptions on the boundary of the condenser.
Źródło:
Annales Universitatis Mariae Curie-Skłodowska, sectio A – Mathematica; 2012, 66, 2
0365-1029
2083-7402
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska, sectio A – Mathematica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of KERENA emergency condenser
Autorzy:
Bryk, R.
Schmidt, H.
Mull, T.
Wagner, T.
Ganzmann, I.
Herbst, O.
Powiązania:
https://bibliotekanauki.pl/articles/240358.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
Kerena
emergency condenser
Modelica
OpenModelica
kondensacja
kondensator awaryjny
Opis:
KERENA is an innovative boiling water reactor concept equipped with several passive safety systems. For the experimental verification of performance of the systems and for codes validation, the Integral Test Stand Karlstein (INKA) was built in Karlstein, Germany. The emergency condenser (EC) system transfers heat from the reactor pressure vessel (RPV) to the core flooding pool in case of water level decrease in the RPV. EC is composed of a large number of slightly inclined tubes. During accident conditions, steam enters into the tubes and condenses due to the contact of the tubes with cold water at the secondary side. The condensed water flows then back to the RPV due to gravity. In this paper two approaches for modeling of condensation in slightly inclined tubes are compared and verified against experiments. The first approach is based on the flow regime map. Depending on the regime, heat transfer coefficient is calculated according to specific semi-empirical correlation. The second approach uses a general, fully-empirical correlation. The models are developed with utilization of the object-oriented Modelica language and the open-source OpenModelica environment. The results are compared with data obtained during a large scale integral test, simulating loss of coolant accident performed at Integral Test Stand Karlstein (INKA). The comparison shows a good agreement. Due to the modularity of models, both of them may be used in the future in systems incorporating condensation in horizontal or slightly inclined tubes. Depending on his preferences, the modeller may choose one-equation based approach or more sophisticated model composed of several exchangeable semi-empirical correlations.
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 29--51
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experience in the development and operation of asynchronized turbogenerators and condensers in the Russian Power System
Autorzy:
Shakaryan, Y.
Sokur, P.
Powiązania:
https://bibliotekanauki.pl/articles/950651.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronized machine
condenser
doubly-fed machine
reactive power
vector control
Opis:
Asynchronized (doubly-fed) machines with two (three) excitating winding and reversing excitation system allow to control vector of magnetomotive force. This solution allows separating regulation of the electromagnetic torque (active power) and voltage (reactive power). This paper describes the experience in the development and operation of asynchronized turbogenerators and condensers.
Źródło:
Archives of Electrical Engineering; 2015, 64, 1; 7-15
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the effectiveness of the turbine condenser air extraction system using hydro ejectors
Autorzy:
Badur, J.
Kowalczyk, T.
Ziółkowski, P.
Tokarczyk, P.
Woźniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/175162.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
steam condenser
Venturi nozzle
Dalton’s law
partial pressure
Opis:
The aim of the paper is to investigate the effectiveness of the 18K380 steam turbine condenser air extraction system using hydro ejectors. Motivation for the analysis was a need of improvement of the energy conversion ratio of the power plant. To achieve this goal it was necessary to establish efficiency of each subsystem of the energy cycle. The air extraction system is not a highly power consuming system but it has great impact on the steam cycle efficiency by influence on the condensation temperature. The air extraction system effectiveness depends on a weather conditions, exactly on the ambient temperature, which raises the question whether it is worth to modernize the hydro ejectors or replace them by a centrifugal vacuum pumps. To establish the vacuum system effectiveness a new innovative mass flow measuring system has been implemented to measure an air-steam mixture flow and the fraction of the air mass in the mixture. The measuring system is based on a Venturi nozzle supplemented with a temperature drop during the mixture expansion.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 41-53
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of energy potential of three ways of configuration of a condenser power plant thermal cycle
Autorzy:
Chmielniak, T.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/258540.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Comparative analysis of energy
condenser
power plant
thermal cycle
new regeneration
separation preheater
Opis:
A theoretical, comparative analysis of three configuration ways of a condenser power plant thermal cycle is shown in the work. A new regeneration & separation preheater and its application in a thermal cycle is presented. Results obtained allow to compare all three analysed configurations efficiencies.
Źródło:
Polish Maritime Research; 2008, 4; 30-36
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza sprawności obiegu cieplnego ultra-nadkrytycznego bloku kondensacyjnego dla szeregowej konfiguracji skraplaczy
The influence of application of a serial condenser for the ultra-critical power unit
Autorzy:
Wróblewski, W.
Łukowicz, H.
Rulik, S.
Powiązania:
https://bibliotekanauki.pl/articles/173112.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
obieg cieplny
ultra-nadkrytyczny blok kondensacyjny
skraplacz
thermal cycle
ultra-supercritical condensing unit
condenser
Opis:
Przedmiotem niniejszej analizy jest dobór parametrów oraz konfiguracji układu chłodzenia dla bloku ultra-nadkrytycznego o mocy 900 MW. Analizę pracy skraplacza oparto o amerykańską normę Heat Exchange Institute. Przedstawione badania obejmują porównanie dwóch wariantów układu chłodzenia, które dotyczą konfiguracji równoległej oraz szeregowej pracy skraplacza. Układ równoległy jest powszechnie stosowany, a rozdzielenie strumienia wody chłodzącej na poszczególne skraplacze bądź sekcje skraplacza daje w nich jednakowe warunki kondensacji. W przypadku konfiguracji szeregowej całkowity strumień wody chłodzącej przepływa szeregowo przez skraplacz pierwszy, a następnie trafia do skraplacza drugiego. Takie rozwiązanie w stosunku do układu równoległego powoduje wzrost sprawności obiegu wynikający z obniżenia całkowitego ciśnienia w skraplaczu. Konfiguracja szeregowa powoduje, że obniżeniu ciśnienia w pierwszej sekcji skraplacza towarzyszy nieznaczny wzrost ciśnienia w drugiej sekcji skraplacza. Stąd też pole powierzchni wymiany ciepła drugiej sekcji skraplacza jest często zwiększone w celu poprawy warunków kondensacji. Niniejsza praca stanowi uzupełnienie oraz rozszerzenie przedstawionych w literaturze analiz. Dotyczy to w szczególności dokładnego uwzględnienia wpływu straty wylotowej turbiny niskoprężnej na wartość uzyskiwanych przyrostów sprawności obiegu cieplnego w przypadku konfiguracji szeregowej pracy skraplacza.
The aim of this paper is the selection of parameters and configuration of the cooling system of 900 MW ultra-supercritical power unit. The performed analysis of the condenser was based on the Heat Exchange Institute standard. The presented studies include comparison of two variants of cooling water system. Both, the parallel and serial configuration of the condenser was investigated. Parallel cooling water system is widely used, and the separation of the cooling water stream into individual sections of the condenser or condensers give equal conditions of condensation. In the case of a serial configuration, the total flow of cooling water flows through the first condenser and then it goes to the second condenser. This causes the decrease of pressure in the first and increase of pressure in the second condenser. Hence, the heat exchange surface area of the second condenser is often increased to improve the conditions of condensation. This paper extends the analyzes presented in the literature. It particularly concerns the investigation of influence of the exhaust loss for obtained efficiency gains in case of the serial configuration of condenser.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 117-127
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy analysis of an air heat pump for hot water
Analiza energetyczna powietrznej pompy ciepla dla CWU
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792485.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
energy
heat pump
hot water
operational parameter
condenser
rotary compressor
storage tank
experimental study
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2016, 16, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steam condensation analysis in a power plant condenser
Autorzy:
Drożyński, Z.
Powiązania:
https://bibliotekanauki.pl/articles/240848.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
heat transfer
inert gases
power plant condenser
kondensacja
transport ciepła
gazy obojętne
skraplacz energetyczny
Opis:
Proposed is the analysis of steam condensation in the presence of inert gases in a power plant condenser. The presence of inert, noncondensable gases in a condenser is highly undesirable due to its negative effect on the efficiency of the entire cycle. In general, thermodynamics has not provided an explicit criterion for assessing the irreversible heat transfer process. The method presented here enables to evaluate precisely processes occurring in power plant condensers. This real process is of particular interest as it involves a number of thermal layers through which heat transfer is observed. The analysis was performed using a simple, known in the literature and well verified Berman’s model of steam condensation in the presence of non-condensable gases. Adapted to the geometry of the condenser, the model enables, for instance, to recognise places where non-condensable gases are concentrated. By describing with sufficient precision thermodynamic processes taking place in the vicinity of the heat transfer area segment, it is possible to determine the distributions of thermodynamic parameters on the boundaries between successive layers. The obtained results allow for the recognition of processes which contribute in varying degrees to irreversible energy degradation during steam condensation in various parts of the examined device.
Źródło:
Archives of Thermodynamics; 2018, 39, 4; 3-32
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of emergency condenser system response to loss of coolant accident in a BWR III+ generation
Modelowanie zachowania systemu kondensatora awaryjnego w przypadku awarii utraty chłodziwa w reaktorze BWR generacji III+
Autorzy:
Bryk, Rafał
Schmidt, Holger
Mull, Thomas
Powiązania:
https://bibliotekanauki.pl/articles/300663.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
boiling water reactor
emergency condenser
LOCA
Modelica
reaktor wodny wrzący
kondensator awaryjny
awaria utraty chłodziwa
Opis:
Emergency Condenser (EC) is a heat exchanger composed of a large number of slightly inclined U-tubes arranged horizontally. The inlet header of the condenser is connected with the top part of the Reactor Pressure Vessel (RPV), which is occupied by steam during critical operation. The lower header in turn is linked with the RPV below the liquid water level during normal operation of the reactor. The tube bundle is filled with cold water and it is located in a vessel filled with water of the same temperature. Thus, the EC and RPV form together a system of communicating vessels. In case of an emergency and a decrease of the water level in the RPV, the water flows gravitationally from U-tubes to the RPV. At the same time the steam from the RPV enters to the EC and condenses due to its contact with cold walls of the EC. The condensate flows then back to the RPV due to the tubes inclination. Hence, the system removes heat from the RPV and serves as a high- and low-pressure injection system at the same time. In this paper a model of the EC system is presented. The model was developed with Modelica modeling language and OpenModelica environment which had not been used in this scope before. The model was verified against experimental data obtained during tests performed at INKA (Integral Test Facility Karlstein) ̶ a test facility dedicated for investigation of the passive safety systems performance of KERENA ̶ generation III+ BWR developed by Framatome.
Kondensator awaryjny jest wymiennikiem ciepła złożonym z dużej ilości U-rurek lekko nachylonych względem pozycji horyzontalnej. Kolektor wlotowy kondensatora połączony jest pojedynczym przewodem z górną częścią zbiornika ciśnieniowego reaktora, w której w trakcie normalnej pracy reaktora znajduje się para wodna. Dolny kolektor połączony jest natomiast ze zbiornikiem ciśnieniowym poniżej lustra wody w stanie ciekłym. Wiązka rurek kondensatora, w trakcie krytycznej pracy reaktora, wypełniona jest zimną wodą i zanurzona jest w basenie z wodą o tej samej temperaturze. Wiązka rurek kondensatora oraz rur doprowadzających tworzą wraz ze zbiornikiem ciśnieniowym zespół naczyń połączonych. W razie sytuacji awaryjnej, w przypadku spadku poziomu wody w zbiorniku ciśnieniowym, woda z kondensatora spływa grawitacyjnie do zbiornika ciśnieniowego, a para, która dostaje się do U-rurek kondensuje na skutek wymiany ciepła z zimną wodą otaczającą kondensator od zewnątrz. W ten sposób kondensator działając pasywnie, zastępuje wysokociśnieniowy oraz niskociśnieniowy wtrysk wody chłodzącej do zbiornika ciśnieniowego. W artykule przedstawiono model systemu kondensatora awaryjnego wraz ze zbiornikiem ciśnieniowym. Model został wykonany przy użyciu niestosowanego wcześniej w tym zakresie języka Modelica oraz środowiska OpenModelica. Następnie opracowany kod został zweryfikowany poprzez porównanie wyników z pomiarami eksperymentalnymi przeprowadzonymi na obiekcie INKA (Integral Test Facility Karlstein) – obiekcie testowym dedykowanym badaniom nad pasywnymi systemami bezpieczeństwa reaktora KERENA – reaktora BWR generacji III+ opracowanego przez firmę Framatome.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 3; 468-475
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of a tube diameter in a ‘church window’ condenser based on entropy generation minimization
Autorzy:
Laskowski, R.
Rusowicz, A.
Grzebielec, A.
Powiązania:
https://bibliotekanauki.pl/articles/240523.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
entropy generation minimization
power plant condenser
tube diameter
minimalizacja entropii generacji
skraplacz energetyczny
średnica rurek
Opis:
The internal diameter of a tube in a ‘church window’ condenser was estimated using an entropy generation minimization approach. The adopted model took into account the entropy generation due to heat transfer and flow resistance from the cooling-water side. Calculations were performed considering two equations for the flow resistance coefficient for four different roughness values of a condenser tube. Following the analysis, the internal diameter of the tube was obtained in the range of 17.5 mm to 20 mm (the current internal diameter of the condenser tube is 22 mm). The calculated diameter depends on and is positively related to the roughness assumed in the model.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 49-59
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of the solid fouling effect on the air-cooled apparatus characteristics
Autorzy:
Morozyuk, Larisa
Sokolovska-Yefymenko, Viktoriia
Moshkatiuk, Andrii
Hrudka, Bohdan
Powiązania:
https://bibliotekanauki.pl/articles/2014236.pdf
Data publikacji:
2021
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
air condenser
fouling
experimental bench
heat exchange surface
chłodnica powietrza
zanieczyszczenie
stanowisko doświadczalne
powierzchnia wymiany ciepła
Opis:
External fouling on the heat exchange surface of air-cooled apparatus are formed during operation, which leads to a significant increase in energy consumption and deviations from the optimal operating mode of the entire system. This phenomenon is a problem for all energy conversion systems. This paper presents the experimental study results of a complex of a commercial cooled object with real fouling on the air condenser surface. To study the effect of fouling, an experimental bench was developed – a single-stage refrigerating machine that provides cold supply to a thermostatic chamber. Three types of fouling were used: sand, fluff and dust. Fouling were picked from the operating condensers and identical in the type of heat exchange surface to the experimental sample. With a change in the quantitative and qualitative composition of the fouling, the air condenser thermal and aerodynamic characteristics and the energy efficiency of the machine as a whole were determined. The experiment showed that at maximum fouling of the heat exchange surface with sand and fluff, air movement stops. This means that at a certain thickness of sand and fluff layer, an air impermeable dense structure is formed. Dust with the same form of filling the free space for the flow remains permeable to air. Experiments showed that the qualitative composition of the fouling is the main factor that determines the heat exchanger performance. It was found that from the experimental set of fouling, roadside dust has the greatest negative effect on the condenser characteristics and the machine as a whole. The aerodynamic properties of the heat exchanger depend to some extent on the qualitative composition of the fouling. As a conclusion, it was suggested that the process nature of air flow passing through the investigated fouling can be described as gas flows in porous media.
Źródło:
Science, Technology and Innovation; 2021, 12, 1; 1-9
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analyzis of the stream-air mixture during a flow through a tube bank inside a condenser
Autorzy:
Krzyślak, P.
Joachimiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/175261.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condenser
pressure drop
steam-air mixture
water vapor condensation in a solution with air
partial pressure
Opis:
The paper presents the results of calculations related to the flow analysis of a tube bank taking into account the partial pressures of gases flowing through the condenser. Different mass share of the gas not condensing in the heat exchanger upstream to the first row of tubes and the partial pressures of water vapor and air have been taken into account. The value of the partial pressures of gases, pressures drop, temperature, velocity, Reynolds number, and air share in the subsequent rows of tubes have been calculated. This study is a basis for the analysis of heat exchange in the condenser considering the influence of the noncondensing gas. The increase in the share of air in the following rows of tubes results in an increase in the thermal resistance and condensation of increasingly lower mass of water vapor.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2014, 126; 131-140
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer during condensation of refrigerants in tubular minichannels
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/239949.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chłodzenie
kompaktowy kondensator
kondensacja w minikanałach
wymiana ciepła
compact condenser
condensation in minichannels
heat transfer
refrigeration
Opis:
Abstract The present paper describes the results of experimental investigations of heat transfer during condensation of R134a, R404A and R407C in pipe minichannels with internal diameters 0.31-3.30 mm. The results concern investigations of the local heat transfer coefficient. The results were compared with the correlations proposed by other authors. Within the range of examined parameters of the condensation process in minichannels made of stainless steel, it was established that the values of the heat transfer coefficient may be described with Akers et al., Mikielewicz and Shah correlations within a limited range of the mass flux density of the refrigerant and the minichannel diameter. On the basis of experimental investigations, the authors proposed their own correlation for the calculation of local heat transfer coefficient.
Źródło:
Archives of Thermodynamics; 2012, 33, 2; 3-22
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations into the influence of functional parameters of a heat pump on its thermal efficiency
Badanie wpływu parametrów funkcjonalnych pompy ciepła na wydajność cieplną
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792384.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
functional parameter
vertical collector
thermal efficiency
scroll type compressor
evaporator
condenser
heat source
coefficient performance
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2013, 13, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical modeling of separation process by coupled heat transfer in the inertial-filtering gas separator-condenser
Matematyczne modelowanie procesu separacji metodą wymiany ciepła podczas kondensacji w układach inercyjno-filtrującej separacji gazu
Autorzy:
Nastenko, O. V.
Liaposhenko, O. O.
Broniarz-Press, L.
Powiązania:
https://bibliotekanauki.pl/articles/2073040.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
inertial-filtering separation
separator-condenser
coupled heat transfer
condensation
inercyjno-filtrująca separacja
separator-skraplacz
wymiana ciepła
kondensacja
Opis:
The paper deals with the condensation method used for inertial filtering separation process. It is a new alternative method in comparison with traditionally used technologies for gas condensate systems depuration using devices for prior condensation. The developed and presented here mathematical model of separation process by coupled heat transfer in the inertial filtering gas separator-condenser can also estimate fluid phase amount condensed during the separation process and the main factors of heat and mass transfer (during the same process).
Przedstawiono nowy sposób inercyjno-filtrującej separacji podczas kondensacji, alternatywny dla tradycyjnie stosowanych technologii procesu oczyszczania z wykorzystaniem urządzeń wstępnej kondensacji. Opracowany model matematyczny separacji z dopasowaną wymianą ciepła w inercyjno-filtracyjnym separatorze-skraplaczu pozwala określić ilość fazy ciekłej, która skrapla się podczas procesu oraz podstawowe wskaźniki wymiany ciepła i masy w analizowanym układzie.
Źródło:
Inżynieria i Aparatura Chemiczna; 2016, 2; 62--63
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vapordynamic thermosyphon – heat transfer two-phase device for wide applications
Autorzy:
Vasiliev, L.
Zhuravlyov, A.
Shapovalov, A.
Rodin, A.
Powiązania:
https://bibliotekanauki.pl/articles/240265.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermosyphon
vapordynamic thermosyphon
long horizontal condenser
porous coating
heat transfer intensification
termosyfon
powłoka porowata
intensyfikacja wymiany ciepła
Opis:
Vapordynamic thermosyphon (VDT) is an efficient heat transfer device. The two-phase flow generation and dynamic interaction between the liquid slugs and vapor bubbles in the annular minichannel of the VDT condenser are the main features of such thermosyphon, which allowed to increase its thermodynamic efficiency. VDT can transfer heat in horizontal position over a long distance. The condenser is nearly isothermal with the length of tens of meters. The VDT evaporators may have different forms. Some practical applications of VDT are considered.
Źródło:
Archives of Thermodynamics; 2015, 36, 4; 65-76
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of wet cooling tower replacement by Heller cooling tower in a power plant
Autorzy:
Malekmohamadi, Mohamad Hasa
Ahmadikia, Hossein
Golmohamadi, Siavas
Khodadadi, Hamed
Powiązania:
https://bibliotekanauki.pl/articles/27309880.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
Heller cooling tower
wet cooling tower
condenser
power plant
wieża chłodnicza Hellera
mokra wieża chłodnicza
skraplacz
elektrownia
Opis:
Water resources are the main component of natural systems affected by climate change in the Middle East. Due to a lack of water, steam power plants that use wet cooling towers have inevitably reduced their output power. This article investigates the replacement of wet cooling towers in Isfahan Thermal Power Plant (ITPP) with Heller natural dry draft cooling towers. The thermodynamic cycle of ITPP is simulated and the effect of condenser temperature on efficiency and output power of ITPP is evaluated. For various reasons, the possibility of installing the Heller tower without increasing in condenser temperature and without changing the existing components of the power plant was rejected. The results show an increase in the condenser temperature by removing the last row blades of the low-pressure turbine. However, by replacing the cooling tower without removing the blades of the last row of the turbine, the output power and efficiency of the power plant have decreased about 12.4 MW and 1.68 percent, respectively.
Źródło:
Archive of Mechanical Engineering; 2023, LXX, 1; 129--149
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat transfer and pressure drop analysis of automotive HVAC condensers with two phase flows in minichannels
Autorzy:
Skiepko, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/2086479.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
air cooled condenser
heat transfer and pressure drop analysis
minichannels
skraplacz chłodzony powietrzem
analiza wymiany ciepła i spadku ciśnienia
minikanały
Opis:
The air cooled automotive condensers under study are of brazed aluminium tube and center, consisting of one row array of horizontal parallel multi-port flat tubes with louver fins on air side. Each tube is with a number of smooth parallel minichannels for internal flow of refrigerant. The analysis uses decomposition of the condenser along refrigerant flow path into specific different zones as follows: two single phase zones, namely: superheated and subcooled, and a few zones of two phase flow that can appear along some specific condensation paths to be: annular/intermittent/bubble or annular/annular-wavy/intermittent/bubble or annular/wavy/stratified. The approach presented is based on experimental correlations for heat transfer and pressure drop. The heat transfer prediction is performed using ε – NTUo methodology. The results of the analysis refer to overall heat transfer rate, heat transfer in particular zones, pressure gradients heat transfer coefficients, vapour quality, condensation paths.
Źródło:
Engineering Management in Production and Services; 2021, 13, 4; 174--188
2543-6597
2543-912X
Pojawia się w:
Engineering Management in Production and Services
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pressure drop during condensation of refrigerants in pipe minichannels
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/240165.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kompaktowy kondensator
przepływ
skraplanie
skraplaniea w minikanałach
spadek ciśnienia
compact condenser
condensation in minichannels
pressure drop during flow in condensation
Opis:
The present paper describes results of experimental investigations of pressure drop during the condensation of R134a, R404a and R407C refrigerants in pipe minichannels with internal diameter 0.31-3.30 mm. The results concern investigations of the mean and local pressure drop in single minichannels. The results of experimental investigations were compared with the calculations according to the correlations proposed by other authors. A pressure drop during the condensation of refrigerants is described in a satisfactory manner with Friedel and Garimella correlations. On the basis of the experimental investigations, the authors proposed their own correlation for calculation of local pressure drop during condensation in single minichannels.
Źródło:
Archives of Thermodynamics; 2012, 33, 1; 87-106
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budynek Domu Narkomfinu w Moskwie: lekcje z Republiki Weimarskiej
Building Narkomfin House in Moscow: lessons from the Weimar Republic
Autorzy:
Movilla Vega, D.
Sotoca, A.
Gyurkovich, M.
Powiązania:
https://bibliotekanauki.pl/articles/131891.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Dom Narkomfinu
ZSRR
Niemcy
Ginzburg Moisiej
Strojkom
budownictwo
kondensator społeczny
Ernst May
Narkomfin House
USSR
Germany
Ginzburg Moisey
Stroykom
construction
social condenser
Opis:
W sytuacji niestabilności i zmian, które charakteryzowały Związek Radziecki w latach dwudziestych ubiegłego wieku, grupa architektów-konstruktywistów pod przewodnictwem Moisieja Ginzburga zajmowała się problemem braku mieszkań dla pracowników w dużych sowieckich miastach. Rozwiązania wypracowane przez zespół Ginzburga zostały opracowane pod patronatem Sowieckich platform OSA i Strojkom. Zostały przeprowadzone w trzech kolejnych etapach zwieńczonych budową Domu Narkomfinu. Niemniej, architektoniczna nowoczesność osiągnięta w Narkomfinie była związana z postępami w sektorze budownictwa mieszkaniowego poczynionymi przez ich kolegów z Europy. Niniejszy artykuł podejmuje analizę faktycznych powiązań pomiędzy owym moskiewskim prototypem a zachodnimi modelami, które zaczynały być opracowywane w Europie, a zwłaszcza w Niemczech. Przedmiotowa koncepcja umieszcza badania prowadzone przez zespół Ginzburga w procesie skomplikowanej i niezwykle ważnej asymilacji, która integrowała nowe modernistyczne techniki Zachodu.
In the scenario of instability and change that characterised the USSR during the 1920s, the group of constructivist architects led by Moisey Ginzburg were tackling the problem of the lack of housing for workers in large Soviet cities. The solutions provided by Ginzburg’s team were developed under the aegis of the Soviet platforms OSA and Stroykom. They were conducted in three successive stages culminating in the building of the Narkomfin House. However, the architectural modernity achieved in Narkomfin was associated to the advancements in the housing building sector made by their European contemporaries. This article analyses the actual connections between the building of this Moscow prototype and Western models that were beginning to be developed in Europe, especially in Germany. This conception repositions the research conducted by Ginzburg’s team within a process of complex and critical assimilation that integrated the new modern Western techniques.
Źródło:
Teka Komisji Urbanistyki i Architektury Oddział PAN w Krakowie; 2018, 46; 177-196
0079-3450
2450-0038
Pojawia się w:
Teka Komisji Urbanistyki i Architektury Oddział PAN w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the GMC-1000 and GMC-2000 mine cooling units for central air-conditioning in underground mines
Zastosowanie górniczego urządzenia chłodniczego GMC-1000 i GMC-2000 w centralnej klimatyzacji kopalń podziemnych
Autorzy:
Wojciechowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/218941.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
centralna klimatyzacja kopalń podziemnych
agregat chłodniczy
parownik
skraplacz
wydajność chłodnicza
obieg lewobieżny
central air conditioning of underground mines
cooling unit
evaporator
condenser
cooling power
Opis:
The paper describes the design and results of operating measurements of the GMC-1000 and GMC- 2000 Mine Cooling Units. The first part describes the design of the cooling unit and its key components: the chiller, evaporator, condenser, oil cooler, evaporative water cooler and gallery air cooler. The possibilities of use in central air conditioning systems of underground mines are described. The second part discusses the results of the workstation and operating measurements and determines the coefficients for evaluating the performance of the mine cooling unit.
Wraz ze wzrostem głębokości eksploatacji pogarszają się warunki pracy w wyrobiskach podziemnych, a w szczególności warunki klimatyczne związane ze wzrostem temperatury. Przy temperaturach pierwotnych górotworu przekraczających 40°C utrzymanie temperatury w wyrobiskach eksploatacyjnych poniżej wartości 28°C, uznawanej za wartość dopuszczalną ze względu na warunki pracy załogi, wymaga, oprócz zwiększonej wydajności wentylacji wyrobisk, także ich klimatyzacji. Można znaleźć wiele prac dotyczących tych zagadnień. Problemów klimatyzacji i chłodzenia wyrobisk dotyczą między innymi prace: Filka i jego zespołu (1999, 2002, 2004, 2006), Łuska i Nawrata (2002), Kalukiewicza i jego zespołu (2008). W krajowym górnictwie dotyczy to zarówno kopalń węgla kamiennego, jak też rud miedzi. W większości przypadków konieczność utrzymania wymaganych warunków klimatycznych w rejonie, przy jednoczesnym nacisku na ekonomiczną stronę procesu pozyskiwania kopalin, powodują konieczność stosowania klimatyzacji grupowej przy zastosowaniu urządzeń o dużej wydajności zlokalizowanych na dole kopalni. W niniejszym artykule omówiono wybrane zagadnienia doboru urządzeń klimatyzacji grupowej na przykładzie urządzenia chłodniczego GMC-1000 i GMC-2000. Konstrukcję urządzenia opracowano w firmie EUROTECH Sp. z o.o. przy współpracy z pracownikami Katedr Maszyn Górniczych Przeróbczych i Transportowych oraz Systemów Energetycznych i Urządzeń Ochrony Środowiska Wydziału Inżynierii Mechanicznej i Robotyki Akademii Górniczo-Hutniczej w Krakowie w ramach projektu dofinansowanego przez Ministerstwo Nauki i Szkolnictwa Wyższego. Górnicze urządzenie chłodnicze jest przeznaczone do chłodzenia powietrza wentylacyjnego w chodnikach wydobywczych kopani podziemnych. Znajduje zastosowanie wszędzie tam, gdzie panują trudne warunki wydobywcze powodowane między innymi dużymi obciążeniami cieplnymi. Wysokie temperatury utrudniają prace górnicze. Powodują konieczność skrócenia czasu przebywania pracowników w rejonach o najwyższych temperaturach. W połączeniu z zapyleniem i wilgotnością stanowią istotny problem przy eksploatacji maszyn i urządzeń ścianowych. Agresywna atmosfera powoduje znacznie szybsze zużycie sprzętu. Problemy te uzasadniają konieczność stosowania systemów chłodzenia powietrza bezpośrednio w rejonach, w których prowadzone jest wydobycie. Górnicze urządzenie chłodnicze GMC stanowi kompletny system chłodzenia powietrza wentylacyjnego w chodnikach wydobywczych. Realizowane zadania powodują, że system ten musi być rozbudowany pod względem technicznym jak również przestrzennym. Część zadań stawianych przed urządzeniem chłodniczym jest realizowana w znacznej odległości od chodników wydobywczych. Dotyczy to przygotowania wody chłodzącej, która służy do schładzania powietrza w chłodnicach ścianowych. Woda z rejonu jej schładzania przepływa rurociągami do rejonów wydobywczych, gdzie jest wykorzystywana do chłodzenia powietrza. Urządzenie pracuje w układzie zamkniętym. Należy zwrócić uwagę, że system chłodzenia musi spełniać wszystkie wymagania określone przez odpowiednie przepisy górnicze dotyczące zasad eksploatacji i bezpieczeństwa. Podstawowymi elementami górniczego urządzenia chłodniczego są następujące aparaty (rys. 1): agregat chłodniczy, chłodnica wyparna wody, chłodnica chodnikowa powietrza. Wymienione aparaty są urządzeniami, w których następują przepływy ciepła. Mają one różny charakter w zależności od przeznaczenia danego elementu. Urządzenie chłodnicze jest uzupełnione dodatkowymi elementami, które są niezbędne do jego prawidłowego funkcjonowania. Do grupy tej należą maszyny z układami napędowymi wymuszające przepływy czynników w poszczególnych wymiennikach ciepła. Mamy tutaj wentylatory i sprężarki czynników gazowych oraz pompy do wody jak również cieczy technologicznych. Urządzenie chłodnicze musi być wyposażone w dodatkowy sprzęt i aparaturę kontrolno-pomiarową. Konieczne są filtry do gazu i cieczy. Czujniki przepływu, temperatury i ciśnienia. Schemat górniczego urządzenia chłodniczego z opisem poszczególnych elementów jest pokazany na rysunku 1. W ramach projektu celowego nr 6 ZR8 2007C/06934 wykonane zostało Górnicze Urządzenie Chłodnicze przeznaczone do klimatyzacji grupowej (centralnej) w kopalniach podziemnych. Konstrukcję urządzenia opracowano w firmie EUROTECH Sp. z o.o. przy współpracy z pracownikami Katedry Maszyn Górniczych Przeróbczych i Transportowych oraz Katedry Systemów Energetycznych i Urządzeń Ochrony Środowiska Wydziału Inżynierii Mechanicznej i Robotyki Akademii Górniczo-Hutniczej w Krakowie. Prototyp urządzenia był badany w WUCH „PZL - Dębica” S.A., następnie przeszedł próby ruchowe w O. ZG „ Rudna”. Obecnie kilka egzemplarzy górniczego urządzenia chłodniczego jest eksploatowanych w kopalniach węgla kamiennego. Prototyp urządzenia GMC-1000 miał moc chłodniczą 1000 kW, wykonano również egzemplarz GMC-2000 o mocy chłodniczej 2000 kW. W tabelach 1-3 przedstawiono wyniki pomiarów agregatu GMC-1000 przeprowadzonych na prototypie oraz wyniki uzyskane w czasie eksploatacji w Kopalni Węgla „Rydułtowy-Anna”, tabela 4 zawiera wyniki uzyskane w czasie eksploatacji urządzenia GMC-2000 w Kopalni Węgla „Bielszowice”. Urządzenie chłodnicze w kopalni „Rydułtowy- Anna” pracuje od lutego 2009. W trakcie prób, za pomocą regulatora wydajności, zmieniano wydajność sprężarki chłodniczej. Regulator wydajności zapewnia płynną regulację strumienia od 0% do 100%. Ilość sprężanych par czynnika R134a w danej chwili, a tym samym zmianę wydajności sprężarki, uzyskuje się za pomocą sterowanego hydraulicznie suwaka regulacji wydajności. Temperatura wody lodowej dopływającej do parownika (tw5) była stabilna w trakcie poszczególnych pomiarów, ale specyfika stanowiska nie pozwalała na utrzymanie stałej wartości temperatury dla kolejnych prób. Wynikał stąd rozrzut wartości tw5 w granicach 11,1°C do 17,4°C. Kolejną wielkością regulowaną była temperatura parowania to (cienienie parowania), która w trakcie pomiarów była zmieniana w granicach -1,4°C do +1,4°C. Badania eksploatacyjne miały na celu sprawdzenie przydatności agregatu do pracy w warunkach kopalnianych. Poszczególne próby były realizowane przy różnych wartościach nastaw i wielkości wejściowych układu. Brak możliwości ustalenia wartości wybranych parametrów wynikał z faktu przeprowadzania pomiarów w czasie prowadzenia prac wydobywczych w O.ZG „Rudna”. Wartości wielkości wejściowych zależały od chwilowego stanu obciążeń i warunków otoczenia. Temperatura wody lodowej dopływającej do parownika była stabilna w trakcie poszczególnych pomiarów (tylko te były przyjmowane jako reprezentatywne), ale zmieniała się ze względu na współpracę agregatu z działającymi w wyrobisku chłodnicami powietrza. Temperatura tw5 zmieniała się w granicach 12,7°C÷19,1°C. Kolejną wielkością regulowaną była temperatura parowania to (ciśnienie parowania), która w trakcie pomiarów zmieniała się w granicach -1,1°C. Uzyskane przez górniczą maszynę chłodniczą GMC-1000 i GMC-2000 wartości parametrów pracy na stanowisku badawczym i przy próbach ruchowych potwierdziły przyjęte założenia projektowe. Wartości parametrów założone na etapie projektowania zostały osiągnięte w trakcie badań stanowiskowych. Założona moc chłodnicza wynosiła 1000 kW, w czasie pomiarów udało się osiągnąć moc chłodniczą 1250 kW. Moc ta została osiągnięta przy 100% nastawie suwaka regulującego przepływ czynnika chłodniczego przez sprężarkę i spadku temperatury wody lodowej w parowniku 11,4 K. Wynik ten daje 25% zapas mocy chłodniczej względem mocy chłodniczej nominalnej, spadek temperatury wody lodowej, w tym przypadku, jest mniejszy o 15,5% w stosunku do założonego. Zapas mocy jest większy w stosunku do niedoboru spadku temperatury oznacza to, że możliwe jest osiągnięcie wymaganego spadku temperatury nawet przy mniejszych mocach chłodniczych. Stwarza to możliwość regulacji parametrów pracy urządzenia chłodniczego w szerokim zakresie. W kilku pomiarach uzyskane temperatury schłodzenia wody były korzystniejsze niż to założono na etapie projektowania GMC. Szerokie przedziały zmienności wartości parametrów stwarzają duże możliwości sterowania pracą górniczych maszyn chłodniczych GMC-1000 i GMC-2000. Osiągnięcie wymaganego stopnia schłodzenia wody lodowej pozwoli na wymagane schłodzenie powietrza w chłodnicy ścianowej. Rezultaty uzyskane w czasie prób stanowiskowych, ruchowych i eksploatacji w kopalniach pozwalają na stwierdzenie, że górnicza maszyna chłodnicza może być eksploatowana w centralnych układach klimatyzacyjnych kopalń podziemnych.
Źródło:
Archives of Mining Sciences; 2013, 58, 1; 199-216
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advances in Digitization of Microphones and Loudspeakers
Autorzy:
Kulka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/177402.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electret condenser microphone
digital microphone
CMOS-MEMS digital microphone
digital microphone array
sigma-delta ADC/DAC
digital loudspeaker
CMOS-MEMS digital loudspeaker
digital loudspeaker array
Opis:
The development of digital microphones and loudspeakers adds new and interesting possibilities of their applications in different fields, extended from industrial, medical to consumer audio markets. One of the rapidly growing field of applications is mobile multimedia, such as mobile phones, digital cameras, laptop and desktop PCs, etc. The advances have also been made in digital audio, particularly in direct digital transduction, so it is now possible to create the all-digital audio recording and reproduction chains potentially having several advantages over existing analog systems.
Źródło:
Archives of Acoustics; 2011, 36, 2; 419-436
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adaptive reliability structures of heat exchange surface in turbine condenser
Adaptacyjne struktury niezawodnościowe powierzchni wymiany ciepła skraplacza turbiny parowej
Autorzy:
Łukaszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1365369.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
adaptive reliability structure
reliability
turbine condenser
designing of heat exchangers
exploitation of heat exchangers
adaptacyjna struktura niezawodnościowa
niezawodność
skraplacz turbiny parowej
projektowanie wymienników ciepła
eksploatacja wymienników ciepła
Opis:
In this paper adaptive reliability structures of heat exchange surface in turbine condenser was proved from the angle of effective heat exchange in variable conditions of its exploitation. Then, determinant factors for design and exploitation in assessment of reliability of pipe subsystem in turbine condenser were suggested. The influence of change of scheme of the pipes, constituting the surface of heat exchange, which stems from the matter of regulating the surface in an attempt to both condense the given amount of steam and maintain the given pressure in the condenser in variable conditions of its exploitation on the reliability of the pipe subsystem was determined. The surface of heat exchange is regulated by enabling and disabling the flow of cooling water through given amount of pipes, in a given way, that is by enabling or disabling possible combination of given pipes in given exploitation conditions. An algorithm to assess the reliability of the pipe subsystem in the condenser in given exploitation conditions, means of regulating the surface and up-to-date technical condition was put forward. The reliability of pipe subsystem has a significant influence either on reliability of the condenser while exploited or in the further course, indirectly on sustaining the requested reliability in the power system therein. Effective operation of the condenser in technical power system is performed by sustaining the given pressure of steam condensation, which is vital in maintaining the required energy efficiency of technical power system in variable exploitation conditions. The exemplification of the aspects put forward in the paper pertains to steam turbine condensers.
W artykule wykazano adaptację struktur niezawodnościowych powierzchni wymiany ciepła skraplacza turbiny parowej z punktu widzenia efektywnej wymiany ciepła w zmiennych warunkach jego eksploatacji. Następnie, wskazano istotne uwarunkowania projektowo-eksploatacyjne oszacowania niezawodności podsystemu rur skraplacza turbiny parowej. Wykazano wpływ zmian układów rur stanowiących powierzchnię wymiany ciepła, które wynikają ze sposobu regulacji tej powierzchni w celu skroplenia zadanej ilości pary wodnej i utrzymywania zadanej wartości ciśnienia w skraplaczu w zmiennych warunkach jego eksploatacji, na niezawodność podsystemu rur. Powierzchnię wymiany ciepła reguluje się poprzez włączanie i wyłączanie przepływu wody chłodzącej przez zadaną liczbę rur, w określony sposób tzn. poprzez włączanie albo wyłączanie możliwych kombinacji określonych układów rur w zadanych warunkach eksploatacyjnych. Przedstawiono algorytm oszacowania niezawodności podsystemu rur skraplacza względem określonych warunków eksploatacyjnych, sposobu regulacji tej powierzchni i aktualnego stanu technicznego. Niezawodność podsystemu rur ma istotny wpływ na niezawodność skraplacza turbiny parowej w czasie jego eksploatacji, a dalej pośrednio na utrzymywanie wymaganej niezawodności systemu energetycznego, w którym występuje. Efektywne funkcjonowanie skraplacza w technicznym systemie energetycznym jest realizowane poprzez utrzymywanie zadanego stałego ciśnienia skraplania pary wodnej, co jest istotne z punktu widzenia utrzymywania wymaganej sprawności energetycznej technicznego systemu energetycznego w różnych warunkach eksploatacyjnych. Egzemplifikacja zawartych w pracy zagadnień odnosi się do rurowych skraplaczy turbin parowych.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 1; 153-159
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-28 z 28

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies