Wyszukujesz frazę "condenser" wg kryterium: Temat


Tytuł:
Optimizing the values of the selected scalar quantities in designing a condenser of marine steam turbine according to the adopted criteria in this designing
Autorzy:
Łukaszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/243452.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
heat exchangers
optimization of condenser
designing of condenser
Opis:
The paper presents designing activities concerning the rating of the values of scalar quantities optimized in accordance with the accepted criteria in designing a condenser of marine steam turbine, which result from the forecasted characteristic, most frequently occurring set points of steam turbine power appearing during the operation of a sea ship. It refers to the method of designing heat exchangers contained in the paper [1] and to the issues raised in the publication [2]. The paper also presents exemplary computational results of the above-mentioned optimized scalar quantities, which refer to designing a shell and tube condenser of marine steam turbine. It was assumed in the paper that the values of mass the mass flow rate of the steam: one p m , 0.75 p m , 0.5 p m , which result from the assumed characteristic set points of marine steam turbine, which occur during the operation of a sea ship. Then, the selected designing activities referring to the above-mentioned optimization were exemplified. On the basis of the computational results, it was shown that the appropriate division of heat exchange area into the definite numbers of condensers, which results from the operation of steam turbine of a definite sea ship, increases operation effectiveness of these condensers in relation to one marine steam turbine condenser. This is a result of optimal values retention: velocity of cooling water of the definite condenser or condensers and temperature of this water on the output of this condenser or condensers during characteristic set points in the operation conditions defined in designing. Next, economic advantages were pointed out, which resulted from the described in the paper, technical solution. These advantages constitute the designing criterion that must be taken into consideration while making a decision about the division of heat exchange area into the definite number of condensers of marine steam turbine. Finally, the conclusions resulting from the paper’s contents are presented.
Źródło:
Journal of KONES; 2014, 21, 2; 193-199
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining steam condensation pressure in a power plant condenser in off-design conditions
Autorzy:
Laskowski, Rafał
Smyk, Adam
Ruciński, Adam
Szymczyk, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1954999.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power plant
steam condenser
condenser model
steam condensation
pressure
reference parameters
steam condenser effectiveness
Opis:
The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena konstrukcji skraplacza na podstawie minimum strumienia generacji entropii
The condenser design assessment on the basis of the minimum entropy generation
Autorzy:
Laskowski, R.
Rusowicz, A.
Grzebielec, A.
Jaworski, M.
Powiązania:
https://bibliotekanauki.pl/articles/271317.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
skraplacz
minimum generacji strumienia entropii
ocena konstrukcji skraplacza
condenser
minimum entropy generation
condenser design assessment
Opis:
W skraplaczach energetycznych generowane są jedne z największych strat strumienia entropii w instalacji energetycznej. Celowe jest obniżanie tej straty, aby uzyskać poprawę całkowitej sprawności instalacji. W artykule podano warunek dla minimum generacji strumienia entropii, z którego wynika, że minimum to jest osiągnięte, gdy podgrzew wody w rurkach skraplacza ma równomierny rozkład (przyjmuje taką samą wartość dla wszystkich rurek). Poprawność tego warunku sprawdzono na podstawie danych uzyskanych z symulatora 2D skraplacza dla jednego z krajowych bloków o mocy 50 MW. Na podstawie otrzymanych z symulatora przyrostów temperatur oraz odpowiadających im ciśnień pary dla 30 rurek dokonano oceny poprawności konstrukcji skraplacza.
The losses in power plants condensers are some of the biggest losses in the entropy generation in whole power plant system. It is advisable to decrease the loss for improving the overall efficiency of the system. The article presents the condition for the minimum entropy generation, which states that the minimum is achieved when the heating of the water in the tubes of the condenser has a uniform distribution (takes the same value for all tubes). The correctness of this condition was verified on the basis of data obtained from the 2D condenser simulator for one of the national units with a 50 MW electric capacity. On the basis of the simulator increases temperatures and steam pressures corresponding to 30 tubes assesses the correctness of the construction of the condenser.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 2; 76-84
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mitigation of voltage flicker by superconducting synchronous Condenser (SUPERVAR)
Autorzy:
Tsai, S. S.
Liu, Y.
Ingram, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/262647.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
superconductivity
synchronous condenser
voltage flicker
power quality
Opis:
Voltage flicker caused by the electric arc furnace (EAF) and the mitigation using the superconducting synchronous condenser (SuperVAR) by the American Superconductor Corp. are considered in this paper. The modeling of EAF, SuperVAR and the system used are discussed. Fast reactive power support to reduce voltage flicker problem by an EAF is desirable. The voltage fluctuation amplitude is used as an index to evaluate the effectiveness of SuperVAR for two different MVar levels. At the PCC (point of common coupling) bus, the application of the SuperVAR can improve the voltage flicker by 6% and 19% by applying DC1A type and AC4A type exciter to the SuperVAR. With an DC1A type exciter, the SuperVAR can output only between +1 and -2 MVAR and with an AC4A type exciter the SuperVAR can provide its full rated power (8MVAR) to the system, making the voltage flicker a less severe.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 39-44
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Entropy generation in a condenser and related correlations
Autorzy:
Laskowski, R.
Jaworski, M.
Smyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/240683.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam condenser
entropy generation
kondensator pary
generowanie entropii
Opis:
The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Źródło:
Archives of Thermodynamics; 2015, 36, 2; 27-48
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Equality cases for condenser capacity inequalities under symmetrization
Autorzy:
Betsakos, Dimitrios
Pouliasis, Stamatis
Powiązania:
https://bibliotekanauki.pl/articles/747114.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
Steiner symmetrization
Schwarz symmetrization
polarization
condenser
capacity
Green function
Opis:
It is well known that certain transformations decrease the capacity of a condenser. We prove equality statements for the condenser capacity inequalities under symmetrization and polarization without connectivity restrictions on the condenser and without regularity assumptions on the boundary of the condenser.
Źródło:
Annales Universitatis Mariae Curie-Skłodowska, sectio A – Mathematica; 2012, 66, 2
0365-1029
2083-7402
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska, sectio A – Mathematica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of KERENA emergency condenser
Autorzy:
Bryk, R.
Schmidt, H.
Mull, T.
Wagner, T.
Ganzmann, I.
Herbst, O.
Powiązania:
https://bibliotekanauki.pl/articles/240358.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
Kerena
emergency condenser
Modelica
OpenModelica
kondensacja
kondensator awaryjny
Opis:
KERENA is an innovative boiling water reactor concept equipped with several passive safety systems. For the experimental verification of performance of the systems and for codes validation, the Integral Test Stand Karlstein (INKA) was built in Karlstein, Germany. The emergency condenser (EC) system transfers heat from the reactor pressure vessel (RPV) to the core flooding pool in case of water level decrease in the RPV. EC is composed of a large number of slightly inclined tubes. During accident conditions, steam enters into the tubes and condenses due to the contact of the tubes with cold water at the secondary side. The condensed water flows then back to the RPV due to gravity. In this paper two approaches for modeling of condensation in slightly inclined tubes are compared and verified against experiments. The first approach is based on the flow regime map. Depending on the regime, heat transfer coefficient is calculated according to specific semi-empirical correlation. The second approach uses a general, fully-empirical correlation. The models are developed with utilization of the object-oriented Modelica language and the open-source OpenModelica environment. The results are compared with data obtained during a large scale integral test, simulating loss of coolant accident performed at Integral Test Stand Karlstein (INKA). The comparison shows a good agreement. Due to the modularity of models, both of them may be used in the future in systems incorporating condensation in horizontal or slightly inclined tubes. Depending on his preferences, the modeller may choose one-equation based approach or more sophisticated model composed of several exchangeable semi-empirical correlations.
Źródło:
Archives of Thermodynamics; 2017, 38, 4; 29--51
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experience in the development and operation of asynchronized turbogenerators and condensers in the Russian Power System
Autorzy:
Shakaryan, Y.
Sokur, P.
Powiązania:
https://bibliotekanauki.pl/articles/950651.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronized machine
condenser
doubly-fed machine
reactive power
vector control
Opis:
Asynchronized (doubly-fed) machines with two (three) excitating winding and reversing excitation system allow to control vector of magnetomotive force. This solution allows separating regulation of the electromagnetic torque (active power) and voltage (reactive power). This paper describes the experience in the development and operation of asynchronized turbogenerators and condensers.
Źródło:
Archives of Electrical Engineering; 2015, 64, 1; 7-15
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the effectiveness of the turbine condenser air extraction system using hydro ejectors
Autorzy:
Badur, J.
Kowalczyk, T.
Ziółkowski, P.
Tokarczyk, P.
Woźniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/175162.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
steam condenser
Venturi nozzle
Dalton’s law
partial pressure
Opis:
The aim of the paper is to investigate the effectiveness of the 18K380 steam turbine condenser air extraction system using hydro ejectors. Motivation for the analysis was a need of improvement of the energy conversion ratio of the power plant. To achieve this goal it was necessary to establish efficiency of each subsystem of the energy cycle. The air extraction system is not a highly power consuming system but it has great impact on the steam cycle efficiency by influence on the condensation temperature. The air extraction system effectiveness depends on a weather conditions, exactly on the ambient temperature, which raises the question whether it is worth to modernize the hydro ejectors or replace them by a centrifugal vacuum pumps. To establish the vacuum system effectiveness a new innovative mass flow measuring system has been implemented to measure an air-steam mixture flow and the fraction of the air mass in the mixture. The measuring system is based on a Venturi nozzle supplemented with a temperature drop during the mixture expansion.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 41-53
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of energy potential of three ways of configuration of a condenser power plant thermal cycle
Autorzy:
Chmielniak, T.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/258540.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Comparative analysis of energy
condenser
power plant
thermal cycle
new regeneration
separation preheater
Opis:
A theoretical, comparative analysis of three configuration ways of a condenser power plant thermal cycle is shown in the work. A new regeneration & separation preheater and its application in a thermal cycle is presented. Results obtained allow to compare all three analysed configurations efficiencies.
Źródło:
Polish Maritime Research; 2008, 4; 30-36
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza sprawności obiegu cieplnego ultra-nadkrytycznego bloku kondensacyjnego dla szeregowej konfiguracji skraplaczy
The influence of application of a serial condenser for the ultra-critical power unit
Autorzy:
Wróblewski, W.
Łukowicz, H.
Rulik, S.
Powiązania:
https://bibliotekanauki.pl/articles/173112.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
obieg cieplny
ultra-nadkrytyczny blok kondensacyjny
skraplacz
thermal cycle
ultra-supercritical condensing unit
condenser
Opis:
Przedmiotem niniejszej analizy jest dobór parametrów oraz konfiguracji układu chłodzenia dla bloku ultra-nadkrytycznego o mocy 900 MW. Analizę pracy skraplacza oparto o amerykańską normę Heat Exchange Institute. Przedstawione badania obejmują porównanie dwóch wariantów układu chłodzenia, które dotyczą konfiguracji równoległej oraz szeregowej pracy skraplacza. Układ równoległy jest powszechnie stosowany, a rozdzielenie strumienia wody chłodzącej na poszczególne skraplacze bądź sekcje skraplacza daje w nich jednakowe warunki kondensacji. W przypadku konfiguracji szeregowej całkowity strumień wody chłodzącej przepływa szeregowo przez skraplacz pierwszy, a następnie trafia do skraplacza drugiego. Takie rozwiązanie w stosunku do układu równoległego powoduje wzrost sprawności obiegu wynikający z obniżenia całkowitego ciśnienia w skraplaczu. Konfiguracja szeregowa powoduje, że obniżeniu ciśnienia w pierwszej sekcji skraplacza towarzyszy nieznaczny wzrost ciśnienia w drugiej sekcji skraplacza. Stąd też pole powierzchni wymiany ciepła drugiej sekcji skraplacza jest często zwiększone w celu poprawy warunków kondensacji. Niniejsza praca stanowi uzupełnienie oraz rozszerzenie przedstawionych w literaturze analiz. Dotyczy to w szczególności dokładnego uwzględnienia wpływu straty wylotowej turbiny niskoprężnej na wartość uzyskiwanych przyrostów sprawności obiegu cieplnego w przypadku konfiguracji szeregowej pracy skraplacza.
The aim of this paper is the selection of parameters and configuration of the cooling system of 900 MW ultra-supercritical power unit. The performed analysis of the condenser was based on the Heat Exchange Institute standard. The presented studies include comparison of two variants of cooling water system. Both, the parallel and serial configuration of the condenser was investigated. Parallel cooling water system is widely used, and the separation of the cooling water stream into individual sections of the condenser or condensers give equal conditions of condensation. In the case of a serial configuration, the total flow of cooling water flows through the first condenser and then it goes to the second condenser. This causes the decrease of pressure in the first and increase of pressure in the second condenser. Hence, the heat exchange surface area of the second condenser is often increased to improve the conditions of condensation. This paper extends the analyzes presented in the literature. It particularly concerns the investigation of influence of the exhaust loss for obtained efficiency gains in case of the serial configuration of condenser.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 117-127
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy analysis of an air heat pump for hot water
Analiza energetyczna powietrznej pompy ciepla dla CWU
Autorzy:
Szreder, M.
Powiązania:
https://bibliotekanauki.pl/articles/792485.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
energy
heat pump
hot water
operational parameter
condenser
rotary compressor
storage tank
experimental study
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2016, 16, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steam condensation analysis in a power plant condenser
Autorzy:
Drożyński, Z.
Powiązania:
https://bibliotekanauki.pl/articles/240848.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
heat transfer
inert gases
power plant condenser
kondensacja
transport ciepła
gazy obojętne
skraplacz energetyczny
Opis:
Proposed is the analysis of steam condensation in the presence of inert gases in a power plant condenser. The presence of inert, noncondensable gases in a condenser is highly undesirable due to its negative effect on the efficiency of the entire cycle. In general, thermodynamics has not provided an explicit criterion for assessing the irreversible heat transfer process. The method presented here enables to evaluate precisely processes occurring in power plant condensers. This real process is of particular interest as it involves a number of thermal layers through which heat transfer is observed. The analysis was performed using a simple, known in the literature and well verified Berman’s model of steam condensation in the presence of non-condensable gases. Adapted to the geometry of the condenser, the model enables, for instance, to recognise places where non-condensable gases are concentrated. By describing with sufficient precision thermodynamic processes taking place in the vicinity of the heat transfer area segment, it is possible to determine the distributions of thermodynamic parameters on the boundaries between successive layers. The obtained results allow for the recognition of processes which contribute in varying degrees to irreversible energy degradation during steam condensation in various parts of the examined device.
Źródło:
Archives of Thermodynamics; 2018, 39, 4; 3-32
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of emergency condenser system response to loss of coolant accident in a BWR III+ generation
Modelowanie zachowania systemu kondensatora awaryjnego w przypadku awarii utraty chłodziwa w reaktorze BWR generacji III+
Autorzy:
Bryk, Rafał
Schmidt, Holger
Mull, Thomas
Powiązania:
https://bibliotekanauki.pl/articles/300663.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
boiling water reactor
emergency condenser
LOCA
Modelica
reaktor wodny wrzący
kondensator awaryjny
awaria utraty chłodziwa
Opis:
Emergency Condenser (EC) is a heat exchanger composed of a large number of slightly inclined U-tubes arranged horizontally. The inlet header of the condenser is connected with the top part of the Reactor Pressure Vessel (RPV), which is occupied by steam during critical operation. The lower header in turn is linked with the RPV below the liquid water level during normal operation of the reactor. The tube bundle is filled with cold water and it is located in a vessel filled with water of the same temperature. Thus, the EC and RPV form together a system of communicating vessels. In case of an emergency and a decrease of the water level in the RPV, the water flows gravitationally from U-tubes to the RPV. At the same time the steam from the RPV enters to the EC and condenses due to its contact with cold walls of the EC. The condensate flows then back to the RPV due to the tubes inclination. Hence, the system removes heat from the RPV and serves as a high- and low-pressure injection system at the same time. In this paper a model of the EC system is presented. The model was developed with Modelica modeling language and OpenModelica environment which had not been used in this scope before. The model was verified against experimental data obtained during tests performed at INKA (Integral Test Facility Karlstein) ̶ a test facility dedicated for investigation of the passive safety systems performance of KERENA ̶ generation III+ BWR developed by Framatome.
Kondensator awaryjny jest wymiennikiem ciepła złożonym z dużej ilości U-rurek lekko nachylonych względem pozycji horyzontalnej. Kolektor wlotowy kondensatora połączony jest pojedynczym przewodem z górną częścią zbiornika ciśnieniowego reaktora, w której w trakcie normalnej pracy reaktora znajduje się para wodna. Dolny kolektor połączony jest natomiast ze zbiornikiem ciśnieniowym poniżej lustra wody w stanie ciekłym. Wiązka rurek kondensatora, w trakcie krytycznej pracy reaktora, wypełniona jest zimną wodą i zanurzona jest w basenie z wodą o tej samej temperaturze. Wiązka rurek kondensatora oraz rur doprowadzających tworzą wraz ze zbiornikiem ciśnieniowym zespół naczyń połączonych. W razie sytuacji awaryjnej, w przypadku spadku poziomu wody w zbiorniku ciśnieniowym, woda z kondensatora spływa grawitacyjnie do zbiornika ciśnieniowego, a para, która dostaje się do U-rurek kondensuje na skutek wymiany ciepła z zimną wodą otaczającą kondensator od zewnątrz. W ten sposób kondensator działając pasywnie, zastępuje wysokociśnieniowy oraz niskociśnieniowy wtrysk wody chłodzącej do zbiornika ciśnieniowego. W artykule przedstawiono model systemu kondensatora awaryjnego wraz ze zbiornikiem ciśnieniowym. Model został wykonany przy użyciu niestosowanego wcześniej w tym zakresie języka Modelica oraz środowiska OpenModelica. Następnie opracowany kod został zweryfikowany poprzez porównanie wyników z pomiarami eksperymentalnymi przeprowadzonymi na obiekcie INKA (Integral Test Facility Karlstein) – obiekcie testowym dedykowanym badaniom nad pasywnymi systemami bezpieczeństwa reaktora KERENA – reaktora BWR generacji III+ opracowanego przez firmę Framatome.
Źródło:
Eksploatacja i Niezawodność; 2019, 21, 3; 468-475
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of a tube diameter in a ‘church window’ condenser based on entropy generation minimization
Autorzy:
Laskowski, R.
Rusowicz, A.
Grzebielec, A.
Powiązania:
https://bibliotekanauki.pl/articles/240523.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
entropy generation minimization
power plant condenser
tube diameter
minimalizacja entropii generacji
skraplacz energetyczny
średnica rurek
Opis:
The internal diameter of a tube in a ‘church window’ condenser was estimated using an entropy generation minimization approach. The adopted model took into account the entropy generation due to heat transfer and flow resistance from the cooling-water side. Calculations were performed considering two equations for the flow resistance coefficient for four different roughness values of a condenser tube. Following the analysis, the internal diameter of the tube was obtained in the range of 17.5 mm to 20 mm (the current internal diameter of the condenser tube is 22 mm). The calculated diameter depends on and is positively related to the roughness assumed in the model.
Źródło:
Archives of Thermodynamics; 2015, 36, 3; 49-59
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies