Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cable" wg kryterium: Temat


Tytuł:
Some Comments on Fatigue Life Tests of Aircraft Cable Control Systems
Autorzy:
Brzęczek, Józef
Powiązania:
https://bibliotekanauki.pl/articles/2105148.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
aircraft’s cable control systems
cable service life
cable fatigue tests
Opis:
Cable control systems are widely used in aircraft and gliders.This paper deals with the problem of collecting real loads acting cable control systems and cable tests preparation (load spectrum) and performance. The author proposes a method for defining real loads acting on control systems, preparing and carrying out fatigue tests of cables revealing symptoms of fretting. The fatigue tests results can be used to predict service life, to plan and prepare periodic and details inspections. This method could be used to increase service life of aircraft control cables and could help to replace the commonly used Time-Based Maintenance (TBM) strategy with the Damage Tolerance (DT).
Źródło:
Fatigue of Aircraft Structures; 2020, 12; 102--112
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Fatigue Life of Cables in Aircraft Flight Control Systems
Autorzy:
Kubryn, M.
Gruszecki, H.
Pieróg, L.
Chodura, J.
Pietruszka, J.
Brzęczek, J.
Powiązania:
https://bibliotekanauki.pl/articles/98016.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
fatigue
cable flight control systems
cable endurance tests
Opis:
The cable flight control systems are commonly used for the control of small airplanes. In these systems, the cables are the only elements transmitting loads from the pilot to the control surfaces. During a flight the cables are moving through pulleys and are subjected to variable loads. A simple analysis of stress in the cable shows that the stress generated by the cyclical bending on the pulleys causes the fatigue of the wires. This phenomenon was noticed on a military aircraft of the M28 family during periodic maintenance inspection in 2007. The endurance tests of KSAN cables of the diameter equal to 3.5 mm and 1.8 mm were performed at the PZL MIELEC. The tests showed the limited fatigue life of the cables due to a progressive increase in the number of broken wires.
Źródło:
Fatigue of Aircraft Structures; 2018, 10; 53-62
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of environment on condition of location damage in screen of the coaxial cable
Autorzy:
Tarczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/97499.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
damage of cable shield
surround of cable
fault localization
pulse methods
Opis:
This paper presents the results of laboratory tests of influence of the environment on pulses propagation conditions in the screen of coaxial cable. The reference level for the screen is the environment, which in real maintenance conditions, is the soil or it could be the inner work conductor. The objective of this work is to determine the possibility of using the pulse method for fault location of screen isolation of electric power cable line or telecommunication line. The special measurement system is described, which allows taking measurements of the influence of different substances types, which surround the location of damage, on the propagation of testing pulses. The results of measurements are shown in oscillograms obtained for typical substances which surround the cable in real exploitation conditions.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 199-208
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System ochrony sieci kablowych SPOT
SPOT - monitoring system for cable networks
Autorzy:
Borzycki, K.
Gajewski, P.
Dziubak, S.
Jabłoński, M.
Powiązania:
https://bibliotekanauki.pl/articles/317430.pdf
Data publikacji:
2013
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
hermetyzacja sieci
kable miedziane
kable światłowodowe
monitoring
oprogramowanie
sieci kablowe
cable networks
fault location
copper cable
optical fiber cable
software
Opis:
W artykule przedstawiono metody monitoringu technicznego telekomunikacyjnych sieci kablowych i ich elementów oraz system monitoringu sieci kablowych SPOT opracowany w ramach projektu rozwojowego OR00012612. System ten służy do scentralizowanego wykrywania uszkodzeń i nieuprawnionych ingerencji w sieciach kablowych miedzianych i światłowodowych. Rola monitoringu sieci kablowych wzrasta wobec obserwowanego w ostatnich latach znacznego wzrostu liczby uszkodzeń związanych z robotami budowlanymi i drogowymi oraz kradzieżami kabli.
The paper presents monitoring methods for telecom cable networks and unmanned facilities, as well as SPOT monitoring system developed as result of Polish development grant No. OR00012612. This system performs centralized detection, location and reporting of faults and unauthorized access to copper and optical fibre cable infrastructure. Monitoring of cable networks is recently gaining importance in Poland and several other countries due to significant rise in number of network outages caused by digging, construction work and cable theft.
Źródło:
Telekomunikacja i Techniki Informacyjne; 2013, 1-2; 18-43
1640-1549
1899-8933
Pojawia się w:
Telekomunikacja i Techniki Informacyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie i ocena przewodów i kabli elektrycznych
Testing and assessment of electric cables
Autorzy:
Figiel, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/199234.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
kable elektryczne
instalacje kablowe
badania kabli
electrical cables
cable installations
cable tests
Opis:
Przewody i kable elektryczne, optyczne i telekomunikacyjne, zanim zostaną wprowadzone do obrotu handlowego, podlegają ocenie za którą odpowiada ich producent. Użytkownik instalacji kablowych jest z kolei odpowiedzialny za prawidłowy dobór kabli i przewodów, ze względu na bezpieczeństwo osób użytkujących instalację. W artykule zaprezentowano wymagania dotyczące kabli i przewodów elektrycznych przeznaczonych do stosowania w podziemnych zakładach górniczych oraz zakres badań wymaganych podczas oceny dokonywanej przez ITG KOMAG.
Before being placed on the market, electrical, optical and telecommunication cables shall undergo an assessment under the responsibility of their manufacturer. The user of the cable systems is responsible for the correct selection of cables for the safety of the persons using the system. The article presents the requirements for electrical cables intended for use in underground mines and the scope of tests required during the assessment carried out by ITG KOMAG.
Źródło:
Maszyny Górnicze; 2019, 37, 3; 3-9
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of long-term cable lines load in real operating conditions
Autorzy:
Wesołowski, M.
Niedbała, R.
Kucharski, D.
Hauser, J.
Powiązania:
https://bibliotekanauki.pl/articles/97431.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
cable lines
circuit
electric installations
Opis:
In the article some basic aspects of numerical modeling of cable lines were discussed. Some often found cases, where the cable lines are placed in cable conduits and cable culverts, were analyzed. The analysis results were compared to the classical, circuit-models based approach of such issues. Basic sources of classical models errors, resulting from difficulty to precisely determine the real environmental quantities were calculated and discussed. Utility of numerical, field models was shown and influence of basic simplifications on calculating results was determined.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 205-217
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola konstrukcji wspornych w funkcjonowaniu przewodów ognioodpornych
The Role of Standard Support Structures in Fire – Resistant Cables Operation
Autorzy:
Chybowski, R.
Kustra, P.
Ptak, S.
Powiązania:
https://bibliotekanauki.pl/articles/136582.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
trasy kablowe
konstrukcje wsporne
ochrona przeciwporażeniowa
electric shock prevention
cable supporting structure
electrical cable
Opis:
W artykule omówiono zagadnienia związane z rolą konstrukcji wspornych w zapewnieniu funkcjonowania przewodów ognioodpornych. Przedstawiono wyniki badań laboratoryjnych.
As the operation of fire resistant cables depends on a number of factors, authors of this article decided to conduct a research concerning the role of standard supports structures in fire – resistant cables operation (power supply or signal transmission) in fire conditions. The background of undertaken topic is also the safety of the firefighters involved in fire operation. The article presents and discusses the outcomes of the research.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2013, 2, 46; 40-45
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyczyny powstawania uszkodzeń elektroenergetycznych linii kablowych oraz sposoby ich naprawy
Causes of damage electro-energetic cable lines and methods of their repair
Autorzy:
Chrzan, M.
Pietruszczak, D.
Stankiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/316049.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
izolacja powłoki kabla
kabel elektroenergetyczny
przepięcia
zwarcia
cable shell insulation
power cable
overvoltages
short circuits
Opis:
W artykule omówiono problematykę lokalizacji miejsca uszkodzenia, na skutek zwarć i przerw zupełnych jak i zwarć i przerw niezupełnych, w kablach elektroenergetycznych. Przedstawiono kilka metod lokalizacyjnych, ich porównanie i sposoby zastosowania. Wyszczególniono i przedstawiono najczęstsze przyczyny uszkodzeń lokalizowanych kabli, ich rodzaje i sposoby naprawy. Większość metod sprawdza się w przypadku zastosowania przynajmniej trzech metod lokalizacyjnych łącznie. Przedstawione w artykule sposoby naprawy wykrytych uszkodzeń są sposobami praktycznymi, wykonywanymi na co dzień przez monterów i konserwatorów.
The paper discussed the problem of the location of the damage site as a result of short-circuits and complete breaks as well as short-circuits and incomplete breaks in power cables. Several localization methods are presented, their comparison and methods of application. The most frequent causes of damage to localized cables and their types are listed and presented and ways to repair. Most methods work well when using at least three localization methods together. The methods of repairing the detected defects presented in this paper are practical methods.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 356-367
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uziemienia stanowisk słupowych z głowicami kablowymi
Earthings of pole stands with cable terminations
Autorzy:
Wojtas, S.
Zawodniak, J. J.
Powiązania:
https://bibliotekanauki.pl/articles/267487.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
uziemienia
głowice kablowe
słupy z głowicami kablowymi
earthing
cable termination
pole stand with cable terminations
Opis:
Praca zawiera analizę właściwości statycznych i udarowych uziemień stosowanych w systemie elektroenergetycznym do ochrony przeciwprzepięciowej. W końcowych rozdziałach dokonano analizy konstrukcji systemów uziemień z punktu widzenia skuteczności w systemie ochrony układu izolacyjnego od przepięć oraz podano szereg wskazówek dotyczących właściwego doboru uziemień stanowisk słupowych głowic kablowych. Wskazano też na błędy popełniane na etapie wykonywania uziemień.
The work includes extensive discussion and comparison of the static and impulse properties of the earthing system used in the power surge protection system. The final chapters deal with the design of earthing systems from the point of view of effectiveness in the overvoltage protection system and provide a number of guidelines for the proper selection and construction of earthing pole stands for cable terminations. The errors made during the earthing phase were also indicated.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 56; 107-111
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka termowizyjna zakopanego i uszkodzonego kabla elektrycznego
Thermographic diagnostics of buried and damaged electric cable
Autorzy:
Chybowski, R.
Bednarek, M.
Rybiński, J.
Jokiel, A.
Powiązania:
https://bibliotekanauki.pl/articles/152566.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermographic diagnostic
cable of buried
research
Opis:
W pracy wykazano możliwość wykorzystania techniki termowizyjnej do diagnozowania kabli elektroenergetycznych ułożonych w ziemi. Uszkodzenie kabla zamodelowano grzejnikiem. Badania termograficzne powierzchni ziemi pod którą był zamodelowany defekt kabla wykazały jednak ograniczony zakres zastosowania z uwagi na zbyt dużą graniczną moc potrzebną do określenia śladu cieplnego.
The article presents possible use of thermovision technique in diagnosing electro-energetic cables placed in the ground. The damage in cable condition has been demonstrated on an example of a heater. Thermographic study of the ground surface under which a modeled damaged cable was placed has shown limited application of the technique due to high limiting power needed to determine thermal trace.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 2, 2; 52-53
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of cable dome under various initial conditions
Autorzy:
Cauner, P.
Kmeť, S.
Powiązania:
https://bibliotekanauki.pl/articles/104237.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
cable dome
active member
stiffness
tensegrity
Opis:
The paper focuses on the numerical analysis of Levy cable dome under two various initial conditions. Experimental device of cable dome is equipped with 7×7 wire ropes with diameter ɸ 6 mm. Nevertheless, it is completely changed for 1×19 wire ropes single strand with diameter ɸ 4 mm. The interchange could lead to creation of more adaptive structure for further static and dynamic analyses. Furthermore, it is essential to stress out that force gauges will improve accordingly.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 1; 5-12
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods to assess effects of cable failures caused by fire
Autorzy:
Piljugin, E.
Herb, J.
Röwekamp, M.
Berg, H, P.
Powiązania:
https://bibliotekanauki.pl/articles/2069632.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
cable failure
fire
probabilistic risk assessment
FMEA
Opis:
It is state-of-the-art that a Level 1 PSA also includes a fire PSA for all plant operational states. In performing Fire PSA not only the malfunction of the components has to be assessed but also all supply systems and cables have to be traced for a given component. In the past it was assumed in the case of a fire in a compartment that all components and cables in that compartment are not functional anymore. However, this is in many cases a too conservative approach and could lead to overestimated fire induced core damage frequencies. Therefore, a method is necessary to assess in a more realistic manner the effects of cables failures caused by fire. Such a procedure requires a sound data base on equipment, list of cables and their properties as well as cable routing. Two methods are described which are currently developed. One of them is a cable failure mode and effect analysis which is easier to apply in practice.
Źródło:
Journal of Polish Safety and Reliability Association; 2011, 2, 1; 163--170
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Controlling Autoreclosing on Overhead Lines with Underground Cable Sections Using Traveling-Wave Fault Location Based on Measurements from Line Terminals Only
Autorzy:
Kasztenny, B.
Guzmán, A.
Mynam, M. V.
Joshi, T.
Powiązania:
https://bibliotekanauki.pl/articles/410575.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
traveling waves
fault locating
cable lines
autoreclosing
Opis:
The paper explains principles of fault locating based on traveling waves measured only at line terminals for hybrid lines comprising overhead and cable sections. The paper introduces an adaptive autoreclosing control logic to allow or cancel reclosing based on the location of the fault. The paper includes examples that explain and illustrate these principles.
Źródło:
Present Problems of Power System Control; 2018, 9; 19-33
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tramwaj linowy dla lotniska w Balicach
Concept of cable car for the Balice Airport
Autorzy:
Rokita, T.
Powiązania:
https://bibliotekanauki.pl/articles/193759.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
tramwaj linowy
ropeway
cable car
Opis:
Koncepcja tramwaju linowego na lotnisku w Balicach w Krakowie. Charakterystyka czterech wariantów poprowadzenia trasy tramwaju. Podstawowe parametry techniczne tramwaju linowego dla każdego z wariantów.
The concept of the new cable car for the Balice airport in Cracow. Four options of alternatives routes. Basic technical parameters for all possible solutions.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 13-15
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tramwaj linowy jako środek transportu na lotniskach
Cable Car as a solution for transportation at airports
Autorzy:
Rokita, T.
Powiązania:
https://bibliotekanauki.pl/articles/192555.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
tramwaj linowy
cable car
ropeway
Opis:
Parametry techniczne i możliwości tramwaju linowego. Przykłady zastosowania tramwajów linowych na lotniskach – zrealizowane dotychczas cztery projekty tramwaju linowego na lotniskach w Wielkiej Brytanii, Kanadzie, Meksyku i Katarze.
The article deals with technical requirements and capabilities of cable cars in cities. Examples of application of air rails at the airports – 4 projects of cable cars implemented at the airports in the Great Britain, Canada, Mexico and Quatar.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 6-9
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the fascia-mesh system and sensitivity analysis of a junction force after a laparoscopic ventral hernia repair
Modelowanie układu powięź-siatka i analiza wrażliwości siły połączenia po laparoskopowej operacji przepukliny brzusznej
Autorzy:
Szymczak, C.
Lubowiecka, I.
Tomaszewska, A.
Śmietański, M.
Powiązania:
https://bibliotekanauki.pl/articles/279958.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
biomechanics
ventral hernia repair
cable model
sensitivity analysis
Opis:
In the paper, a simple model of the fascia-mesh system is considered to assess the junction force after a laparoscopic hernia repair. The aim of this study is to develop a cable model of the system in order to find the junction force and to distinguish the most important parameters affecting the system junction force. The cable is subjected to a pressure in the abdominal cavity and displacements of the cable edges caused by bends of the patient body. The attention is paid to the junction force sensitivity analysis with respect to initial tension of the mesh, its length and elasticity as well as fascia flexibility. All these parameters are crucial for ventral hernia repair safety. Finally, some concluding remarks important for practicing surgeons and for further more advanced study using two dimensional fascia-mesh models are presented.
W pracy rozpatrywano prosty model układu powięź-siatka do oszacowania siły połączenia siatki z powięzią po laparoskopowej operacji przepukliny brzusznej. Celem pracy jest zastosowanie modelu cięgna do wyznaczenia siły połączenia tego układu oraz do wyznaczenia najważniejszych parametrów mających wpływ na siłę połączenia implantu z powięzią. W tym celu zastosowano analizę wrażliwości siły połączenia względem wariacji początkowej siły rozciągającej siatki, jej długości i modułu sprężystości oraz podatności powięzi. Cięgno jest obciążone ciśnieniem wewnątrz brzusznym oraz przemieszczeniami jego końców wywołanymi skłonami ciała pacjenta. Wszystkie podane wyżej parametry są istotne dla bezpieczeństwa operacji przepukliny. W wyniku pracy sformułowano pewne wnioski ważne dla chirurgów oraz dla dalszych bardziej zaawansowanych badań z zastosowaniem modeli dwuwymiarowych układu powięź-siatka.
Źródło:
Journal of Theoretical and Applied Mechanics; 2010, 48, 4; 933-950
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Otwarcie mostu podwieszonego przez Skawę w Zembrzycach
Autorzy:
Ciejka, W.
Kowalczyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/365570.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
most
most podwieszony
Zembrzyce
bridge
cable-stayed bridge
Opis:
24 sierpnia 2010 r. dokonano uroczystego otwarcia nowego mostu przez rzekę Skawę w Zembrzycach, stanowiącego przeprawę dla nowo wybudowanej obwodnicy miejscowości Zembrzyce w ciągu drogi wojewódzkiej nr 956 Biertowice - Sułkowice - Zembrzyce.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 6; 68
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cable-suspended CPR-D type Parallel Robot
Autorzy:
Filipovic, M.
Djuric, A.
Powiązania:
https://bibliotekanauki.pl/articles/949223.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
cable-suspended parallel robot
camera observation
kinematics
dynamics
Opis:
This paper deals with the analysis and synthesis of a newly selected Cable-suspended Parallel Robot configuration, named CPR-D system. The camera carrier workspace has the shape of a parallelepiped. The CPR-D system has a unique Jacobian matrix that maps the relationship between internal and external coordinates. This geometric relationship is a key solution for the definition of the system kinematic and dynamic models. Because of the CPR-D system complexity, the Lagrange principle of virtual work has been adapted. Two significant Examples have been used for the CPR-D system analysis and validation.
Źródło:
Journal of Theoretical and Applied Mechanics; 2016, 54, 2; 645-657
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzajemne oddziaływanie aerodynamiczne kabli nośnych w konstrukcjach mostowych
Aerodynamic interaction of the bridge cables
Autorzy:
Gołębiowska, I.
Dutkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/316595.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
analiza numeryczna
most
kabel
numerical analysis
bridge
cable
Opis:
W pracy przedstawione zostały wyniki analizy numerycznej dotyczącej interakcji aerodynamicznej kabli konstrukcji mostowych. Rozważania przeprowadzono dla dwóch różnych przekrojów kabla, kołowego i eliptycznego, znajdujących się w odległości kabli względem siebie, wyrażonej współczynnikiem L/D w zakresie od 1 do 9. Na podstawie przeprowadzonej analizy określono przebiegi linii strumienia dla liczby Reynoldsa Re=65000.
In the paper the results of numerical analysis of aerodynamic interaction of bridge cables is presented. Analysis was performed for different cable's cross section, circular and elliptical, located in the distance described by factor L/D in the range from 1 to 9. The velocity stream lines are presented for Reynolds number Re=65000.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 173-176
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy losses’ reduction in metallic screens of MV cable power lines and busbar bridges composed of single-core cables
Ograniczanie strat energii w żyłach powrotnych linii i mostów kablowych średniego napięcia wykorzystujących kable jednożyłowe
Autorzy:
Andruszkiewicz, Jerzy
Lorenc, Józef
Łowczowski, Krzysztof
Weychan, Agnieszka
Zawodniak, Józef
Powiązania:
https://bibliotekanauki.pl/articles/1365217.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
cable lines
medium voltage network
energy losses
metallic cable screen
linie kablowe
sieć średniego napięcia
straty energii
żyła powrotna
Opis:
The growing share of medium voltage cable lines in distribution networks challenges distribution network operators in terms of proper mode of operation of these lines. It is related to the reduction of energy losses in cable conductors and metallic cable screens. The article focuses on energy losses in metallic cable screens of cable lines and substation busbar bridges composed of single-core cables with metallic screens and possible ways of their reduction. Simulation and measurement analysis of the level of energy losses in the metallic screens of cables is presented together with the economic analysis of various variants of losses reduction through the change of the way these screens are operated in relation to the traditional bilateral earthing at both ends of cable. Technical problems and threats connected with the use of considered modifications of metallic screens operation during earth fault disturbances in distribution networks are also presented.
Rosnące skablowanie linii średniego napięcia w sieciach dystrybucyjnych stawia przed operatorami tych sieci wyzwanie prawidłowej eksploatacji linii kablowych. Powiązane jest to z redukowaniem strat energii w żyłach roboczych i powrotnych kabli. W artykule skupiono się na stratach energii w żyłach powrotnych linii oraz mostów kablowych wykonanych przy wykorzystaniu kabli jednożyłowych z metalicznymi żyłami powrotnymi oraz możliwych sposobach ich ograniczania. Przedstawiono analizę symulacyjną i pomiarową poziomu strat energii w żyłach powrotnych kabli wraz z analizą ekonomiczną różnych wariantów ich redukcji poprzez zmianę sposobu pracy tych żył w stosunku do tradycyjnego obustronnego ich uziemienia. Przedstawione zostały również problemy techniczne oraz zagrożenia związane z zastosowaniem rozważanych modyfikacji pracy żył powrotnych podczas zakłóceń zwarciowych w sieciach dystrybucyjnych.
Źródło:
Eksploatacja i Niezawodność; 2020, 22, 1; 15-25
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dostawa energii elektrycznej i sygnałów do urządzeń przeciwpożarowych
Power supply to fire protection devices
Autorzy:
Zboina, J.
Mroczko, G.
Powiązania:
https://bibliotekanauki.pl/articles/373067.pdf
Data publikacji:
2013
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
kable
zespoły kablowe
ciągłość dostawy energii
ocena zgodności
badania kabli
cables
cable systems
maintenance of circuit integrity
conformity assessment
cable testing
Opis:
W artykule autorzy przedstawiają zagadnienia związane z ciągłością dostawy energii i przekazu sygnału do urządzeń przeciwpożarowych. W pierwszej części artykułu wskazują, jak istotne jest zachowanie ciągłości dostawy energii i sygnału do urządzeń przeciwpożarowych dla bezpieczeństwa pożarowego i warunków bezpiecznej ewakuacji z obiektów budowlanych. W dalszej części skupiają się na definicji zespołu kablowego i wymagań stawianych zespołom kablowym, jak również elementów wchodzących w skład zespołów kablowych. Dalej opisują dostępne na polskim rynku rodzaje kabli stosowanych w ochronie przeciwpożarowej oraz oznaczenia kabli związane z odpornością ogniową. Następnym elementem jest prezentacja konstrukcji nośnych do kabli wraz ze wskazaniem ich charakterystycznych parametrów oraz sposobem klasyfikacji wg normy DIN 4102-12 oraz podstawowymi wymaganiami przy instalacji kabli i zespołów kablowych. W podsumowaniu autorzy wskazują na istotną rolę i obowiązek przeprowadzenia przez producentów/dostawców oceny zgodności wyrobów i uzyskania odpowiednich dokumentów potwierdzających spełnienie przez wyroby stawianych im wymagań.
In this article the authors present information concerning continuity of power and signal supply to fire protection devices. In the first part of the paper the authors indicate how it is important to maintain the continuity of power and signal supply to fire protection devices for fire safety and safe evacuation from buildings. Following that, the authors focus on the definition of a cable system and the requirements established for cable systems and their parts. Next, the authors present the information about cables for fire protection which are available on Polish market and describe cable markings connected with fire resistance. Presentation of cable bearing systems, together with pointing out their specific parameters and classification according to DIN 4102-12 standard, constitutes the following part of the article. Moreover, general requirements for installation of cable and cable systems are presented. In their summary, the authors indicate the importance of performing necessary conformity assessment of products and acquiring of specific documents which confirm product fulfillment of specific requirements.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2013, 3; 111-121
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Working temperature calculation of single-core cable by nonlinear finite element method
Autorzy:
Meng, Xiaokai
Han, Peijie
Liu, Yongxin
Lu, Zhumao
Jin, Tao
Powiązania:
https://bibliotekanauki.pl/articles/141018.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cable
finite element simulation model
thermal conductivity
operating temperature
Opis:
By simulating the actual working conditions of a cable, the temperature variation rule of different measuring points under different load currents was analyzed. On this basis, a three-dimensional finite element model (FEM) was established, and the difference and influence factors between the simulation temperature and the experimental measured value were discussed, then the influence of thermal conductivity on the operating temperature of the conductor layer was studied. Finally, combined with the steady-state thermal conductivity model and the experimental measured data, the relation between thermal conductivity and load current was obtained.
Źródło:
Archives of Electrical Engineering; 2019, 68, 3; 643-656
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of the Electric Field Intensity Distribution Between Wet Surfaces During Cable Aging Process
Autorzy:
Gunes, I.
Powiązania:
https://bibliotekanauki.pl/articles/1032064.pdf
Data publikacji:
2017-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Cable insulation
electric field
dry band arcing
aging test
Opis:
In this study, electric field effect was investigated by dry band arcing test method. ADSS (all-dielectric self-supporting) cables are usually placed on power grids. These cables are affected by temperature and are exposed to many environmental effects such as wind and UV rays. In this study, the effect of water flow over ADSS cable on electric surface erosion on dry surfaces was investigated by electric arcing method, according to IEEE 1222 standard and the electric field intensity at the surface and the electric potential distribution were analyzed using the finite element method.
Źródło:
Acta Physica Polonica A; 2017, 131, 3; 548-550
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of damage to medium and low voltage cable lines in tram traction stations – maintenance experience
Autorzy:
Adamkiewicz, A.
Haraburda, M.
Powiązania:
https://bibliotekanauki.pl/articles/359832.pdf
Data publikacji:
2014
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
power cables
tram traction networks
damage to cable lines
Opis:
The article discusses the problem of damage to the traction cables of medium and low voltage systems for DC tram traction power devices. It presents types and mechanisms of damage to various types of cables and compares a number of failures. Some chosen particularly interesting cases have been discussed.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2014, 38 (110); 5-9
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of additional tension in towed streamer cable triggered by collision with underwater moving object
Autorzy:
Blintsov, Vladimir S.
Trunin, Konstantin S.
Tarełko, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/259687.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
towed steamer cable
collision
deformation mechanism
offshore seismic survey
Opis:
The paper deals with issues connected with the behaviour of a streamer cable towed by a survey seismic vessel when the cable undergoes a strike triggered by collision with an underwater moving object. The consequences of such collisions may be both threat to the life of marine animals or damage to underwater units and large economic losses suffered by vessel owners. The risk of such collisions has increased over the last years as a result of increased offshore seismic survey operations. Therefore, a towed streamer should be very robust. To assure its robustness, we should know the deformation mechanism of a single streamer cable. This in turn requires the development of an appropriate mathematical model of such a phenomenon. In particular, the paper presents the characteristics of seismic survey vessels and streamers; an analysis of collisions that have occurred in the past; a statement of the problem, and a computer-aided system supporting simulation of the cable behaviour. To obtain all the necessary design parameters regarding the deformation mechanism of a streamer cable, we set up a dedicated computer-aided system that supports their calculation.
Źródło:
Polish Maritime Research; 2020, 2; 58-68
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Napowietrzne koleje linowe jako część systemu komunikacji miejskiej
Aerial ropeways as a part of urban transport system
Autorzy:
Magiera, T.
Powiązania:
https://bibliotekanauki.pl/articles/194022.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
miejskie koleje linowe
cable propelled transit
ropeways
Opis:
Rola miejskich kolei linowych jako uzupełniającego systemu przewozów w miastach. Charakterystyka dwóch rozwiązań miejskich systemów transportowych z udziałem kolei linowych w Caracas i Medellin w Ameryce Południowej.
Function of the urban ropeways as a complementary transport system in cities. Characteristics of two solutions of urban transport systems with participation of ropeways in Caracas and Medellin in the South America.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 21-24
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarząd kablem światłowodowym stanowiącym przedmiot współwłasności przymusowej
Management of fiber optic cable constituting the subject of compulsory co-ownership
Autorzy:
Malicki, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/1633671.pdf
Data publikacji:
2019-04-30
Wydawca:
Polskie Wydawnictwo Ekonomiczne
Tematy:
zarząd rzeczą wspólną
kabel światłowodowy
współwłasność przymusowa kabla światłowodowego
zarząd kablem światłowodowym
management of the common property
fiber optic cable
compulsory co-ownership of the fiber optic cable
management of the fiber optic cable
Opis:
Ustawą z 7.05.2010 r. o wspieraniu rozwoju usług i sieci telekomunikacyjnych (u.w.r.u.s.t.) prawodawca wprowadził do polskiego porządku prawnego konstrukcję odrębnej własności części składowej rzeczy ruchomej. Stanowi to wyłom w dotychczasowym postrzeganiu konstrukcji prawnorzeczowych. Możliwości takiej nadal nie przewiduje jednak Kodeks cywilny. Ustanowienie odrębnej własności części składowej dotąd możliwe było jedynie w przypadku nieruchomości. Zgodnie z ustawą możliwe jest ustanowienie odrębnej własności włókna światłowodowego umieszczonego w kablu. Spełnienie ustawowych przesłanek nie powoduje automatycznego wyodrębnienia włókna z kabla światłowodowego. Osiągnięcie takiego skutku wymaga zajścia zdarzenia prawnego wskazanego w ustawie. Z chwilą ustanowienia odrębnej własności pierwszego włókna światłowodowego jednolita struktura prawna kabla światłowodowego ulega dekompozycji. Natomiast kabel stanowi odtąd przedmiot współwłasności przymusowej właścicieli włókien światłowodowych, co wymaga ich współdziałania. Sprawowanie zarządu częściami wspólnymi kabla światłowodowego oparte jest na odpowiednio stosowanych przepisach Kodeksu cywilnego o zarządzie rzeczą wspólną. Zasady te są modyfikowane regulacją ustawy o wspieraniu rozwoju sieci i usług telekomunikacyjnych.
In Supporting the Development of Telecommunications Networks and Services Act of 7th May 2010 legislator introduced into the Polish legal structure of separate ownership constituent of movables. According to the Act of 7 May 2010 it is possible to establish separate ownership of the optical fiber placed in the cable. This is a breach in the existing perception of the design property rights. This possibility is still not in the Civil Code. Separation of ownership of the component previously was only possible in the case of real estate. The fulfillment of the conditions laid down in the act does not automatically extract the fiber optic cable. Achieving this effect requires the occurrence of an event specified in the act. At the time of the separate ownership of the first optical fiber, the uniform legal structure of the fiber optic cable is decomposed. The cable is hence the subject of compulsory co-ownership of fiber optic owners, which requires their cooperation. The management of the common parts of the fiber optic cable is based on properly applied provisions of the Civil Code regarding the management of the common property. These rules are modified by the Supporting the Development of Telecommunications Networks and Services Act of 7th May 2010.
Źródło:
Przegląd Ustawodawstwa Gospodarczego; 2019, 4; 21-26
0137-5490
Pojawia się w:
Przegląd Ustawodawstwa Gospodarczego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kształtowanie mostowych konstrukcji sprężonych na podstawie wniosków z inspekcji zewnętrznych kabli sprężających
Design of prestressed bridge structures based on external prestressing tendons inspection conclusions
Autorzy:
Borsz, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2142045.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
obiekt mostowy
konstrukcja sprężona
awaria
kabel sprężający
kabel zewnętrzny
inspekcja
dostępność
bridge
prestressed construction
failure
prestressing cable
external cable
inspection
accessibility
Opis:
Punktem wyjścia do artykułu są pojawiające się awarie zewnętrznych kabli sprężających opisane w piśmiennictwie zagranicznym jak i coraz częściej w polskich realiach oraz problemy z prowadzeniem prac inspekcyjnych i remontowych na sprężonych obiektach mostowych. Artykuł ma na celu przedstawienie podstawowych zasad kształtowania konstrukcji sprężonych umożliwiających łatwą realizację w fazie budowy oraz prostą inspekcję; serwis jak i remont w fazie użytkowania z uwzględnieniem zapisów wytycznych krajowych oraz zagranicznych. Całość zagadnienia jest omówiona na podstawie istniejących konstrukcji mostowych od fazy projektowania przez użytkowanie i remont ze szczególnym uwzględnieniem odpowiedniego doboru systemu zabezpieczenia antykorozyjnego kabli jak i aspektu inspekcyjnego oraz możliwości wymiany kabli sprężających.
This report’s starting point is about the emerging failures of external prestressing tendons described in foreign literature and more often in the polish infrastructure market. Those failures can be associated with incorrect site implementation works, insufficient and low quality inspections and possible incorrect repairs. The aim of the report is to present the basic assumption of the post tensioned structures with the external post tensioning tendons and optimal strand corrosion protection systems selection to improve the tendons life-time durability, as well as the requirements for the deviators and anchorages including inspection aspects and replacing possibility. The world wide experience and current trends prove that it is necessary to discuss the use of external cables to ensure the designed bridges life span and finally leading to development of national guidelines.
Źródło:
Przegląd Budowlany; 2022, 93, 5-6; 130--135
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of vibration control of a cable with an attached mr damper
Badania eksperymentalne sterowania drganiami liny z dołączonym tłumikiem MR
Autorzy:
Maślanka, M.
Sapiński, B.
Snamina, J.
Powiązania:
https://bibliotekanauki.pl/articles/281461.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
drgania
tłumiki MR
cable vibration
magnetorheological (MR) damper
control
Opis:
The paper presents experimental investigation of a horizontally suspended cable with an MR damper attached transversally near the support. The algorithm proposed to MR damper control employs the concept of emulation of a viscous damper wit h an optimal viscous damping coefficient. The algorithm is realized using a velocity feedback with damping force tracking control is applied. Free vibration of the cable with an MR damper operating in passive and controlled modes are investigated. The obtained results indicate that an appropriately controlled MR damper ensures a nearly constant damping level in a wide range of cable vibration amplitudes.
W artykule przedstawiono wyniki badań eksperymentalnych układu poziomo zawieszonej liny z tłumikiem MR dołączonym poprzecznie w pobliżu podpory. Do sterowania tłumikiem MR przyjęto koncepcję emulacji tłumika wiskotycznego o optymalnym współczynniku tłumienia. Algorytm sterowania zrealizowano przy wykorzystaniu sprzężenia od prędkości oraz nadążnego układu sterowania siłą tłumienia. Analizie poddano drgania swobodne liny z tłumikiem MR pracującym w trybie pasywnym oraz sterowanym. Wyniki badań wskazują, że opracowany algorytm sterowania pozwala na uzyskanie w przybliżeniu stałego poziomu tłumienia drgań liny w szerokim zakresie wartości amplitudy drgań.
Źródło:
Journal of Theoretical and Applied Mechanics; 2007, 45, 4; 893-917
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of harmonic vibration of cable-stayed footbridge under the influence of changes of the cables tension
Autorzy:
Pakos, W.
Powiązania:
https://bibliotekanauki.pl/articles/178830.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
cable-stayed footbridge
FEM model
harmonic vibration
vibration reduction
Opis:
The paper presents numerical analysis of harmonically excited vibration of a cable-stayed footbridge caused by a load function simulating crouching (squats) while changing the static tension in chosen cables. The intentional synchronized motion (e.g., squats) of a single person or group of persons on the footbridge with a frequency close to the natural frequency of the structure may lead to the resonant vibrations with large amplitudes. The appropriate tension changes in some cables cause detuning of resonance on account of stiffness changes of structures and hence detuning in the natural frequency that is close to the excitation frequency. The research was carried out on a 3D computer model of a real structure – a cable-stayed steel footbridge in Leśnica, a quarter of Wrocław, Poland, with the help of standard computer software based on FEM COSMOS/M System.
Źródło:
Studia Geotechnica et Mechanica; 2015, 37, 3; 63-71
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy koleje linowo-terenowe mogą stać się częścią transportu miejskiego?
Can cable railways become an element of urban transport?
Autorzy:
Magiera, T.
Rząsa, K.
Powiązania:
https://bibliotekanauki.pl/articles/193938.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowo-terenowe
transport miejski
cable railway
urban transport
Opis:
Charakterystyka systemów kolei linowo-terenowej (budynki stacyjne, układ napędowy z liną napędową, konstrukcja jezdna wraz z jej elementami, wagony). Kolej linowo-terenowa w Innsbrucku - Hungerburgbahn. Kolej linowo-terenowa w Bilbao.
Characteristics of cable railways systems (station buildings, driving system with driving rope, rolling stock, cars). Cable railway in Innsbruck - Hungerburgbahn. Cable car in Bilbao.
Źródło:
Transport Miejski i Regionalny; 2011, 3; 29-32
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Support and verification of the production process of optical fiber cables using LabView environment
Autorzy:
Paszkiel, S.
Powiązania:
https://bibliotekanauki.pl/articles/114162.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
optical fiber
NI Vision Builder Al
optical fiber cable
LabVIEW
Opis:
In the paper, there is described an original application supporting the production process of optical fiber cables. The production process was improved by automatic search of potential tubing locations, which was conducted using the extension Vision Builder by National Instrument, producer of LabView software. The paper presents production processes that occur during execution of optical fiber ending. The proposed enhancements aim to minimize human factor that could contribute to destruction of the semi-finished product during transport of the optical fiber to the other side of the protection jacket and reduction of production process duration. The proposed vision system was created with NI Vision Builder tool. For the purposes of the conducted work, a control panel was also executed combining minimized functions for controlling the quality of the performed inspection. The user can load images to be analyzed and see the final result of the vision system analysis along with the decision in the form of a message regarding the permission for performing the tubing process or its deny.
Źródło:
Measurement Automation Monitoring; 2016, 62, 9; 312-319
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kable powrotne w łączu SWEPOL LINK
Proposals for protection of return cables on SWEPOL LINK
Autorzy:
Szczepański, T.
Powiązania:
https://bibliotekanauki.pl/articles/266659.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kabel powrotny
ogranicznik przepięć
elektroda
return cable
surge arrester
electrode
Opis:
Kabel powrotny w łączu Szwecja-Polska pojawił się jako alternatywa wymuszona przez ekologów, spowodowana brakiem akceptacji społecznej. Dlatego w wykonanym rozwiązaniu zastąpiono wodę i ziemię dwoma kablami powrotnymi, chociaż z punktu widzenia technicznego wprowadzone rozwiązanie daje niższą sprawność. Ostatnie, jedenaste uszkodzenie kabla powrotnego wystąpiło w 2012 roku. W ośmiu wcześniejszych przypadkach przyczyną awarii były uszkodzenia elektryczne kabla w morzu w odległości kilkunastu kilometrów od polskiego brzegu, spowodowane zakłóceniami w północnej części polskiego systemu elektroenergetycznego. W tej sytuacji dla łącza Szwecja-Polska zaproponowano przeanalizowanie i zrealizowanie jednego lub dwóch niżej przedstawionych rozwiązań, które mogą istotnie ograniczyć skutki i koszty z tytułu uszkodzeń kabli powrotnych: a) montaż dodatkowych ograniczników przepięć, b) powrót do elektrod – całkowity brak kabli powrotnych, c) elektrody „niepełne” pracujące z jednym kablem powrotnym, d) praca łącza jedynie z uziemieniami własnymi na stacjach przekształtnikowych. Reasumując należy stwierdzić, że: - stosunkowo tanim sposobem dalszego uodpornienia kabli powrotnych na uszkodzenia elektryczne jest zabudowa ograniczników przepięć w szafce przy kontenerze na polskim brzegu, - z proponowanych środków zaradczych rozsądnym wydaje się zastosowanie wyżej wymienionych propozycji a) i d) jednocześnie, gdyż są to proste rozwiązania, nie wymagające dużych nakładów finansowych ani jakichkolwiek zgód, a mogą szybko zapewnić oczekiwany rezultat.
The return cable on SwePol Link has been introduced as an alternative enforced by environmentalists due to lack of social acceptance for other solutions. This is why in the proposed solution water and earth have been replaced by two return cables, although from the technical point of view such solution is less effective. The last, eleventh fault of return cable took place on 15 October 2012. In eight earlier cases the faults were caused by electrical failures in the cable in the sea and were located between ten and twenty kilometers from the Polish shore and triggered by disturbances in the northern part of the Polish power grid. In this situation it has been suggested to analyze and introduce one or two solutions shown below which may significantly limit the effects and lower the costs caused by return cable faults: a) assembly of additional surge arresters, b) return to electrodes – lack of return cables, c) “partial” electrodes working with one return cable, d) operation of the link only with earthings on converter stations. To sum up it needs to be said that: - a relatively cheap way of protecting return cables against electrical failures is installing surge arresters in the cabinet located next to the cable container on the Polish shore, - from the suggested preventive measures it seems reasonable to introduce the above mentioned solutions a) and d) simultaneously, as both of them are simple solutions which require neither considerable financial expenditures nor authorizations and may fast show expected results.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 35; 39-44
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozwój napędów dołowych kolejek podwieszonych
Development of drives for underground suspended monorails
Autorzy:
Pieczora, E.
Suffner, H.
Powiązania:
https://bibliotekanauki.pl/articles/199352.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
kolej podwieszona
kolej linowa
kolej jednoszynowa
napęd linowy
napęd spalinowy
napęd akumulatorowy
suspended monorail
cable train
monorail
cable drive
diesel drive
battery drive
Opis:
Przedstawiono w sposób syntetyczny rozwój dołowych kolejek podwieszonych linowych i jednoszynowych. Omówiono jednoszynowe kolejki z napędem linowym, a następnie spalinowym, zwracając uwagę na ich zalety i ograniczenia stosowania. Dokonano analizy unijnych i krajowych wymagań w zakresie toksyczności spalin wskazując na niekonsekwencje istniejących zapisów. Przedstawiono rozwiązania kolejek z napędem akumulatorowym, w tym opracowanego w KOMAG-u ciągnika GAD-1, jako kierunku przyszłościowego.
Development of cable underground suspended monorails is presented in a concise way. Monorails with a cable drive and then with diesel drives are discussed drawing attention to their advantages and limitations of their use. European Union and Polish regulations regarding the requirements exhaust gases toxicity are analysed indicating inconsistencies of the existing provisions. Design solutions of battery driven monorails including the GAD-1 drive train developed in KOMAG are given as the future trend.
Źródło:
Maszyny Górnicze; 2017, 35, 3; 44-57
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proposals for Protection of Return Cables on SwePol Link
Propozycje ochrony kabli powrotnych w łączu Szwecja – Polska
Autorzy:
Szczepański, T.
Powiązania:
https://bibliotekanauki.pl/articles/397506.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
return cable
surge arrester
electrode
kabel powrotny
ogranicznik przepięć
elektroda
Opis:
The return cable on the SwePol Link has been introduced as an alternative forced by environmentalists due to lack of social acceptance of other solutions. This is why in the proposed solution water and earth have been replaced by two return cables, although from a technical point of view such a solution is less effective. The last, eleventh fault of the return cable took place on 15 October 2012. In eight earlier cases the faults were caused by electrical failures in the cable in the sea and were located between ten and twenty kilometers from the Polish shore and triggered by disturbances in the northern part of the Polish power grid. In this situation it has been suggested to analyze and introduce one or two solutions shown below which may significantly limit the effects and lower the costs caused by return cable faults: a) assembly of additional surge arresters b) return to electrodes – lack of return cables c) ”partial” electrodes working with one return cable d) operation of the link only with earthings on converter stations. To sum up it needs to be stated that: • a relatively cheap way of protecting return cables against electrical failures is installing surge arresters in the cabinet located next to the cable container on the Polish shore • from the suggested preventive measures it seems reasonable to introduce the above mentioned solutions a) and d) simultaneously, as both of them are simple solutions which require neither considerable financial expenditure nor authorizations and may quickly show the expected results.
Streszczenie Kabel powrotny w łączu Szwecja – Polska pojawił się jako alternatywa wymuszona przez ekologów. Dlatego w wykonanym rozwiązaniu zastąpiono wodę i ziemię dwoma kablami powrotnymi, chociaż z punktu widzenia technicznego wprowadzone rozwiązanie daje niższą sprawność. Ostatnio do jedenastego uszkodzenia kabla powrotnego doszło 15 października 2012 roku. W ośmiu wcześniejszych przypadkach przyczynami awarii były uszkodzenia elektryczne kabla w morzu, w odległości kilkunastu kilometrów od polskiego brzegu, spowodowane zakłóceniami w północnej części polskiego systemu elektroenergetycznego.
Źródło:
Acta Energetica; 2013, 1; 147-156
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advancements in Optical Fibres Communication
Autorzy:
Singh, Sarthak
Sharma, Himanshu
Powiązania:
https://bibliotekanauki.pl/articles/1075566.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Graphene material
Optical Fiber Cable
Optimization Techniques
Total Internal Reflection
Opis:
Presently the optical fibres are mainly used in the wide area networking (WAN).The major research issues in optical communication are the development of innovative techniques to avoid physical damages, design of the efficient communication techniques and challenges faced by due to ecology & environmental issues.
Źródło:
World Scientific News; 2019, 121; 67-72
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of Aircraft’s Cable Control Systems Tension
Autorzy:
Brzęczek, Józef
Powiązania:
https://bibliotekanauki.pl/articles/103329.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cable
tension measurement
tensiometer validation
kabel
pomiar napięcia
walidacja tensjometru
Opis:
Cable control systems are widely used in GA aircrafts and gliders. The paper deals with the accuracy of measurement pertaining to the tension of cables at the production stage and the maintenance of aeronautical products. Producers of the measuring instruments used to measure tension do not explicitly define how they should be calibrated and stipulate using special methods and stands. The paper discusses a possible method of tension measurement, measuring tools, methods of calibration and possible errors in the adopted measurement and calibration methods as well. The possible error analysis takes into consideration, the stands construction and details: measuring the instruments system, temperature influence length of reference cable, etc.
Źródło:
Advances in Science and Technology. Research Journal; 2019, 13, 2; 65-71
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of temperature field in a three-phase high voltage cable system
Autorzy:
Tykocki, J.
Powiązania:
https://bibliotekanauki.pl/articles/97521.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
Pareto principle
high voltage cable
3-phase system
core temperature
Opis:
A modified "Pareto principle" has been applied to the analysis of the temperature field in three-phase high-voltage cables. In the paper the temperature field is described by thirteen distinct parameters including the geometrical dimensions of the system. By solving the thermal conductivity equation 2p times, it is possible to determine the parameters belonging to set A, which exert a decisive influence on the temperature of the cable core. To describe the ABC sets elements of linear algebra are applied. The paper’s concluding notes present a preliminary optimization procedure of the system.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 51-64
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear buckling analysis of network arch bridges
Autorzy:
Błonka, Adrian
Skrętkowicz, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2086774.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
network arch bridge
post-critical analysis
nonlinear buckling
cable structures
Opis:
The paper presents designing due to the instability in-plane problem of the net-arch bridge. Firstly, three essential nonlinear examples are benchmarked in a finite element software. Secondly, linear and nonlinear buckling analyses are conducted, with the purpose of investigating the impact of nonlinear behavior of cables on steel arch instability, involving a comparison of the critical load factor and form from both the linear buckling and the post-critical third-order theory analyses. The impact of prestress and tension, elevation, and hanger failure on instability is discussed. Moreover, a new method for determining nonlinear buckling form for the net-arch structure is proposed in order to allow implementation of Unique Global and Local Imperfection method in cable structures. Calculations are conducted in the finite element software. The model of the network arch bridge is based on the bridge over Vistula River in Cracow.
Źródło:
Studia Geotechnica et Mechanica; 2022, 44, 2; 123--137
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of material aging on the structural behavior of a flexible roof with a polymer membrane shell
Autorzy:
Chesnokov, Andrei V.
Mikhailov, Vitalii V.
Dolmatov, Ivan V.
Powiązania:
https://bibliotekanauki.pl/articles/29520094.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
polymer membrane aging
creep
stress relaxation
pre-stressed cable roof
Opis:
The roof structure considered in the research consists of continuous cables and a number of spreaders forming a three-dimensional frame. The frame is covered with a polymer membrane made of flexible architectural fabrics. The elements of the roof are compact and suitable for transportation to remote construction sites. The roof also has advantages for developing areas with harsh climatic conditions. The flexible elements of the roof, however, only provide transmission of tensile forces. Under compression, cables slacken and the membrane becomes wrinkled. Pre-tension of the flexible elements, which is introduced to retain the operability of the roof, tends to gradually diminish due to material aging. The aging results in the alteration of strength properties and creep elongation of the structural elements. It induces membrane tearing on local areas. Force alteration in primary structural members is examined in the present study, with statistical methods used for data analysis. They include significance hypothesis testing and correlation coefficients estimation. The data are obtained by the Finite Element simulation of the roof using EASY-2020 software. The results of the work may be used for life expectancy assessment of flexible roof structures, providing important information for the preliminary design stage. The work contributes to the safety enhancement of cable-membrane structures and the expansion of their scope in permanent building constructions.
Źródło:
Computer Methods in Materials Science; 2021, 21, 1; 13-24
2720-4081
2720-3948
Pojawia się w:
Computer Methods in Materials Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Signal propagation in multi-wire cables
Propagacja sygnałów w liniach wieloprzewodowych
Autorzy:
Tarczyński, W.
Kopka, R.
Powiązania:
https://bibliotekanauki.pl/articles/223031.pdf
Data publikacji:
2015
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
multi-wire transmission cable
transmission line model
signal propagation
pulses interaction
cable diagnostics
linia długa wieloprzewodowa
model linii
propagacja sygnałów
oddziaływanie sygnałów
diagnostyka linii
Opis:
The article presents the analysis of the influence of the pulses propagating in the wires of a multi-wire cables. Special attention was drawn to the process of pulses inducing in the wires to which no pulse signal was provided. The pulses interaction occur in those sections of a cable where a change of wave impedance causing a change in the reflectance is present. The pulse interaction changes its shape and amplitude. This pulse interaction can be used to diagnose the technical condition of the electric power and telecommunication cables.
W artykule przedstawiona jest analiza oddziaływania impulsów przemieszczających się w przewodach linii wieloprzewodowych. Zwrócono uwagę na powstawanie impulsów w przewodach, do których nie jest podawany sygnał impulsowy. Oddziaływanie impulsów występuje w miejscach linii, w których jest zmiana impedancji falowej powodująca zmianę współczynników odbicia. Oddziaływanie impulsów powoduje zmianę ich kształtu oraz amplitudy. Zjawisko oddziaływania impulsów można wykorzystać do diagnostyki stanu technicznego linii elektroenergetycznych i telekomunikacyjnych.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2015, R. 56 nr 4 (203), 4 (203); 51-63
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Computer VNA Assisted Measurements of the UTP Cable Transmitting Wide Range Frequency Signals up to 100 MHZ
Autorzy:
Matusiak, M.
Cader, A.
Powiązania:
https://bibliotekanauki.pl/articles/108750.pdf
Data publikacji:
2009
Wydawca:
Społeczna Akademia Nauk w Łodzi
Tematy:
VNA
VNA program
impedance measurement
UTP cable
transmitting line
computer measurement
Opis:
The paper describes some possibilities of the Unshielded Twisted Pair (UTP) cable as an universal signal transmitting line at the range of radiofrequencies from 0,1 to 100 MHz. Four pairs of the UTP in the subject of the impedance of the line with the different load were examined. The Vector Network Analyzer was used as a base measurement equipment [1,2]. Results are clearly shown using charts from the freeware IG-miniVNA computer program. The final experiments conclusion presents the UTP 5e category as a good general purpose transmitting line for universal 100 ohm impedance sources and loads [3].
Źródło:
Journal of Applied Computer Science Methods; 2009, 1 No. 2; 85-91
1689-9636
Pojawia się w:
Journal of Applied Computer Science Methods
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental verification of signal propagation in automotive ignition cables modelled with distributed parameter circuit
Autorzy:
Różowicz, Sebastian
Zawadzki, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/141016.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed parameter circuit
ignition cable
spark plug
ignition system
spark discharge
Opis:
The paper analyses the possibilities of treating the ignition cable in the internal combustion engine as a distributed parameter system. It presents the experimental verification of computer simulations of signal propagation generated by ignition systems in the ignition cables, modelled by the distributed parameter system. The tests conducted to determine the wave parameters of ignition cables, as well as the results of numerical simulations and their experimental verifications, are presented. It is concluded that the modelling of the ignition cable by means of a long line gives positive results that can be used for the design of a spark plug with impedance equal to wave impedance of the ignition cable.
Źródło:
Archives of Electrical Engineering; 2019, 68, 3; 667-675
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A tribological test rig for fibres, cables, and plaitings
Stanowisko do badań tribologicznych włókien, lin i plecionek
Autorzy:
Kowalewski, P.
Brończyk, A.
Wieleba, W.
Powiązania:
https://bibliotekanauki.pl/articles/191061.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
friction
test rig
cable
fibre
tribotester
tarcie
stanowisko badawcze
lina
włókna
Opis:
The paper presents a description of the mechanical construction, measuring and control systems and the possibilities of a new type tribological testing device. The design was developed and built at the Department of Fundamentals of Machine Design and Tribology of Wroclaw University of Science and Technology. Described tester allows the investigate a friction and wear of components such as fibrous tapes, ropes, plaitings or fibers themselves in contact with solid materials. The paper describes in detail the construction of drive and the load pneumatic system. The innovative system of the device such measurement equipped with piezoelectric sensors and an experimental fixing unit of tested components also have been described. Work includes diagrams of used control and measurement systems and the central lubrication system. As a test the polyethylene cable in contact with brass rods has been examined. The results of this studies were been also presented in the paper.
W pracy przedstawiono opis konstrukcji, układów kontrolno-pomiarowych i możliwości nowego typu tribologicznego urządzenia badawczego. Konstrukcja została opracowana i zbudowana w Katedrze Podstaw Konstrukcji Maszyn i Tribologii Politechniki Wrocławskiej. Opisane stanowisko pozwala na prowadzenie badań tarcia i zużywania komponentów włóknistych takich jak taśmy, liny, plecionki lub same włókna podczas kontaktu z materiałami stałymi. W pracy opisano szczegółowo budowę mechaniczną urządzenia wraz z układem napędowym i pneumatycznym układem obciążającym. Przedstawione zostały również zastosowane w urządzeniu nowatorskie rozwiązania układu pomiarowego wyposażonego w czujniki piezoelektryczne oraz innowacyjny sposób mocowania badanych komponentów. Praca zawiera schematy zastosowanych systemów kontrolno-pomiarowych oraz centralnego układu smarowania badanych węzłów tarcia. W ramach testów przeprowadzone zostały badania lin polietylenowych we współpracy z prętami mosiężnymi, a wyniki ww. badań zostały również przedstawione w pracy.
Źródło:
Tribologia; 2017, 271, 1; 51-55
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quadrotor UAV control for transportation of cable suspended payload
Autorzy:
Kusznir, Tom
Smoczek, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/246855.pdf
Data publikacji:
2019
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
transport
UAV
quadrotor
under actuated
cable suspended payload
sliding mode control
Opis:
Payload transportation with UAV’s (Unmanned Aerial Vehicles) has become a topic of interest in research with possibilities for a wide range of applications such as transporting emergency equipment to otherwise inaccessible areas. In general, the problem of transporting cable suspended loads lies in the under actuation, which causes oscillations during horizontal transport of the payload. Excessive oscillations increase both the time required to accurately position the payload and may be detrimental to the objects in the workspace or the payload itself. In this article, we present a method to control a quadrotor with a cable suspended payload. While the quadrotor itself is a nonlinear system, the problem of payload transportation with a quadrotor adds additional complexities due to both input coupling and additional under actuation of the system. For simplicity, we fix the quadrotor to a planar motion, giving it a total of 4 degrees of freedom. The quadrotor with the cable suspended payload is modelled using the Euler-Lagrange equations of motion and then partitioned into translation and attitude dynamics. The design methodology is based on simplifying the system by using a variable transformation to decouple the inputs, after which sliding mode control is used for the translational and pendulum dynamics while a feedback linearizing controller is used for the rotational dynamics of the quadrotor. The sliding mode parameters are chosen so stability is guaranteed within a certain region of attraction. Lastly, the results of the numerical simulations created in MATLAB/Simulink are presented to verify the effectiveness of the proposed control strategy.
Źródło:
Journal of KONES; 2019, 26, 2; 77-84
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Role of cable transport in the management and development of the mountain areas
Autorzy:
Olszyna, G.
Rokita, T.
Tytko, A.
Wójcik, M.
Powiązania:
https://bibliotekanauki.pl/articles/100490.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
cableways
cable transport in the mountains
mountaineering
przewód
transport przewodów
wspinaczka
Opis:
Cable transport has been used for a long time to move people in difficult terrain, mostly moutainous. Since the beginning of the 20th century, this means of transport is inextricably linked to mountain tourism, especially skiing. Cable cars and ski lifts have become the only means of transport for skiers in ski resorts. The article describes the development of cable transport in mountain areas and the benefits that followed. It also presents two examples of ski resorts, which had a significant contribution to development of tourism and skiing in mountain areas.
Źródło:
Geomatics, Landmanagement and Landscape; 2013, 4; 63-74
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of vertical displacements of the esperanto footbridge in Bydgoszcz
Analiza przemieszczeń pionowych kładki esperanto w Bydgoszczy
Autorzy:
Bujarkiewicz, A.
Gajewski, J.
Janiak, T.
Sobczak-Piąstka, J.
Sztubecki, J.
Tews, R.
Powiązania:
https://bibliotekanauki.pl/articles/396462.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
cable-stayed bridge
displacements
FEM model
most wantowy
przemieszczenia
model MES
Opis:
The subject of the research is a footbridge across the river Brda in Bydgoszcz. The measurements of the footbridge displacements with the test load were undertaken. The paper presents the results of the measurements and compares them with the theoretical results obtained using the finite element method (FEM). On this basis, discrepancy between actual work of the structure and numerical simulations was found. Attempt to explain the reasons for the observed differences and direction of further research were included in the conclusions.
Przedmiotem przeprowadzonych badań jest kładka przez rzekę Brdę w Bydgoszczy. W ramach badań wykonano pomiary przemieszczeń kładki przy przyłożonym próbnym obciążeniu. W artykule przedstawiono wyniki przeprowadzonych pomiarów oraz porównano je z wynikami teoretycznymi otrzymanymi przy zastosowaniu metody elementów skończonych (MES). Na tej podstawie stwierdzono rozbieżności pomiędzy rzeczywistą pracą konstrukcji a symulacjami numerycznymi. We wnioskach podjęto próbę wyjaśnienia przyczyn zaobserwowanych różnic oraz wskazano kierunek dalszych badań.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(2); 5-17
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Złoty Most we Władywostoku
Autorzy:
Siedlecka, A.
Powiązania:
https://bibliotekanauki.pl/articles/363796.pdf
Data publikacji:
2012
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
budownictwo mostowe
most wantowy
Rosja
bridge construction
cable-stayed bridge
Russia
Opis:
Złoty Most przez cieśninę Wschodni Bosfor i zatokę Złoty Róg połączył Wyspę Rosyjską z centralną częścią Władywostoku. Obiekt uroczyście otwarto 11 sierpnia 2012 r.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2012, 6; 41
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modifying the Transient Overvoltages in Mixed Power Networks by Inserting Cable Sections
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262837.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
cable
overvoltage
transformer
veutral treatment
transient model
lightning
mixed power networks
Opis:
The paper deals with the analysis of the electromagnetic transients in mixed power net-works. Special emphasis is made on assessing the effectiveness of using cable sections in reducing the transients in the power network components such as transformer substations. A distributed parameter modeling of the overhead lines, underground cables and transformer windings is applied in the Laplace domain. The simulation can handle the different time waveforms of the sources initiating the transients, the lengths of the cable sections as well as the transformers’ neutral treatment. The direct analytical s-domain solution is numerically inverted in order to get the corresponding time domain results. The affecting parameters such as the line and cable surge impedances, the length of the cable section (or its time delay) and the transformer data, are investigated. A case involving multiple-pulse lightning surges is also addressed. The results of four case studies of known solutions are presented in order to validate the developed mathematical model and computer program.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2015, 18, 1; 7-14
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of various factors on the viv-induced fatigue damage in the cable of submerged floating tunnel
Autorzy:
Luo, G.
Chen, J.
Zhou, X.
Powiązania:
https://bibliotekanauki.pl/articles/259555.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
submerged floating tunnel cable
vortex induced vibration
fatigue damage
factor analysis
Opis:
According to the modal superposition method, the vortex vibration procedure of submerged floating tunnel cable was compiled using Matlab, based on the calculated results, the fatigue damage was predicted. The effects of various factors, such as cable density, cable length, and pretension and velocity distribution on vortex induced fatigue damage in the cable were studied. The results show that velocity distribution has more effect on the cable fatigue damage than cable length, cable density and pretension. Secondly, cable length has also relatively effect on the cable damage fatigue, cable density and pretension has limited in a certain range.
Źródło:
Polish Maritime Research; 2015, 4; 76-83
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podejście do linii kablowych jako ważnego elementu w układach zasilania nN poprzez zastosowane izolacje i powłoki kablowe
The approach to cable lines as an important element in nN power supply systems through the insulation and cable coatings used
Autorzy:
Juraszek, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1860979.pdf
Data publikacji:
2020
Wydawca:
Centrum Usług i Projektów Janusz Juraszek
Tematy:
izolacja
kabel energetyczny
układ zasilania
insulation
power cable
power supply systems
Opis:
W artykule przedstawiono parametry techniczne kabli w izolacji i powłoce XLPE/PE vs PVC/PVC ich zalety i wady. Zwrócono uwagę na wpływ samego produktu na proces budowy i jego uproszczenia. Analizując poszczególne etapy życie produktu i ponoszone koszty, zwrócono uwagę na rosnące koszty opex i ponoszonych strat.
The article presents technical parameters of cables in XLPE/PE insulation and sheath vs PVC/PVC their advantages and disadvantages. Attention was paid to the influence of the product itself on the construction process and its simplification. Analyzing the individual stages of product life and costs, attention was paid to increasing opex costs and incurred losses.
Źródło:
Era Energii; 2020, 1; 16-19
2658-0195
Pojawia się w:
Era Energii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-linear stochastic dynamics of a cable-mass system with finite bending stiffness via an equivalent linearization technique
Autorzy:
Weber, Hanna
Kaczmarczyk, Stefan
Iwankiewicz, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/1839662.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
stochastic dynamics
nonlinear systems
cable
finite bending stiffness
equivalent
linearization techniques
Opis:
The non-linear stochastic dynamic behaviour of a high-rise vertical transportation system modelled as a concentrated mass and a cable with finite bending stiffness is considered. The slow time scale is defined and lateral cable displacements coupled with transverse motions are expanded in terms of approximating functions. The excitation of the high-rise building is assumed in the form of a narrow-band mean-square process equivalent to the harmonic process. The equivalent linearization technique is used to replace the original non-linear system with a linear approximation whose coefficients are determined from minimization of the mean-square equation difference between both systems.
Źródło:
Journal of Theoretical and Applied Mechanics; 2020, 58, 2; 483-497
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accurate Location of Fiber Cable Fault with OTDR
Autorzy:
Borzycki, Krzysztof
Gajewski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2058489.pdf
Data publikacji:
2021
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
fault location
fiber optic cable
helix factor
OTDR
single-mode fiber
Opis:
The paper reviews the factors limiting the accuracy of locating a fiber optic cable fault when using an optical time domain reflectometer (OTDR) and describes an error estimation method for typical use cases. The primary source of errors lies in the complex relationship between the length of the optical fiber (measured by OTDR), its routing, cable design depending on cable design and type of installation (i.e. duct, directly buried, aerial) as well as the spare lengths used for service purposes. The techniques which considerably improve the accuracy of the fault localization processes are presented, the importance of accurate documentation of the network and of referencing the fault location to the nearest splice instead of end of the line are discussed, as is the absence of cable helix factor in data sheets.
Źródło:
Journal of Telecommunications and Information Technology; 2021, 4; 42--52
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ tynku na funkcjonowanie przewodów ognioodpornych w pożarze
The Influence of Plaster on Fire – Resistant Cables Operation in Fire Conditions
Autorzy:
Chybowski, R.
Kustra, P.
Ptak, S.
Powiązania:
https://bibliotekanauki.pl/articles/136468.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
przewody ognioodporne
elektroenergetyczne zagrożenia pożarowe
fire resistant cable
electrical fire safety
Opis:
W artykule przedstawiono wyniki badań wpływu tynku na zachowanie ognioodporności przewodów, tzn. na zapewnienie ciągłości dostawy energii elektrycznej do urządzeń przeciwpożarowych.
The article describes and discusses the research results concerning the influence of plaster on fire – resistant cables operation in fire conditions. Mica, wire insulation that remains even in high temperature, becomes fragile and any impact might cause short circuit, though the plaster itself does not deteriorate cables’ operation.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2013, 1, 45; 49-60
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektrohydrauliczne systemy sterowania siłą napinania liny w kolejach napowietrznych
Electro-hydraulic systems for controlling the cable tightening force in aerial cable railways
Autorzy:
Pluta, J.
Powiązania:
https://bibliotekanauki.pl/articles/192857.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
sterowanie
systemy elektrohydrauliczne
cable railway
control
electro-hydraulic system
Opis:
Czynniki związane z eksploatacją i bezpieczeństwem kolei linowych uzależnione od wartości siły napinającej linę. Ogólna struktura elektrohydraulicznych systemów napinania liny. Sterowanie siłą napinania liny na przykładzie własnych rozwiązań urządzeń napinających.
Factors related to the cable railway’s operation and safety depended on the value of cable tightening force. General structure of electro-hydraulic systems for cable tightening. Control of the cable tightening force on the examples of the author’s solutions of tightening devices.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 16-20, 24
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jerzy Bader i jego wkład w rozwój technologii wysokonapięciowych
George Bahder and his contribution in developing high-voltage technology
Autorzy:
Łotysz, S.
Powiązania:
https://bibliotekanauki.pl/articles/268617.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
starzenie się izolacji
przewody wysokiego napięcia
regeneracja izolacji
drzewienie
przemysł kablowy
deterioration of high-voltage cable insulation water
treeing phenomenon
cable industry
recovery of deteriorated cables
Opis:
Artykuł przedstawia osiągnięcia Jerzego Badera, absolwenta Politechniki Warszawskiej, wybitnego specjalisty w dziedzinie technik wysokonapięciowych. Stworzył on m.in. metodę regeneracji kabli uszkodzonych w wyniku wystąpienia zjawiska drzewienia elektrycznego. Bader pracował również nad zagadnieniem produkcji przewodów odpornych na to zjawisko. W artykule przedstawiono przebieg jego kariery zawodowej i złożonych kolei losu, które sprawiły, że ten świetny fachowiec znalazł się za granicą.
The paper analyses the contribution of Polish-born engineer. George Bahder, in developing a method of recovering high-voltage cables deteriorated by a phenomenon known as water treeing. While working for several companies and laboratories in the United States, he was granted 33 patents for his inventions. Among others, he developed a method of regeneration of deteriorated cables, and also he devised an improved cable having a higher resistance to the water treeing phenomena. The paper brings some details on his personal and professional life.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 44; 73-76
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detecting and Locating Signal Leakages from Cable TV Networks : A Case Study
Autorzy:
Taha, Hussein
Vári, Péter
Powiązania:
https://bibliotekanauki.pl/articles/27311975.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
MFCN
cable TV
signal leakage
drive test
digital dividend bands
700 MHz
Opis:
Since the digitalization of terrestrial television, many countries have discontinued television broadcasting in the UHF band. The freed-up frequencies are now available as digital dividends for mobile and fixed wireless access communication networks (MFCN), particularly for 4G/5G and public safety services in broadband called BBPPDR. Since cable TV still uses the UHF band, leakage from cable TV networks is the most common cause of interference in MFCN networks. Insufficient containment of the radio frequency signals transmitted through a cable system results in cable signal leakage. This article investigates the significance of controlling electromagnetic signal leaks from cable TV networks and how they impact authorized and standardized MFCN networks in the digital dividend bands. The periodic drivetest approach to detect and measure electromagnetic leakage from a cable TV system in the 700 MHz band at a site is detailed. The causes of the detected leaks and offered the appropriate procedure to repair them are also discussed. Additionally, the current measures taken in Hungary to address cable television signal leakage in the digital dividend bands are also discussed and alternative strategies for the adopted test drive approach are proposed.
Źródło:
International Journal of Electronics and Telecommunications; 2023, 69, 3; 529--536
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar wyładowań niezupełnych w liniach kablowych średniego napięcia
Autorzy:
Noske, S.
Powiązania:
https://bibliotekanauki.pl/articles/397020.pdf
Data publikacji:
2009
Wydawca:
ENERGA
Tematy:
pomiar wyładowań
linia kablowa SN
wyładowania niezupełne
MV cable lines
partial discharges
Opis:
Linie kablowe SN stanowią istotny składnik majątku sieciowego przedsiębiorstw dystrybucyjnych. Przy ich pomocy zasilane są obszary najbardziej zurbanizowane, obszary gdzie odbiorcy są szczególnie wrażliwi na przerwy w dostawie energii elektrycznej a skutki usuwania awarii wiążą się ze znacznymi kosztami. Dotychczasowe zarządzanie tą siecią oparte było głownie o analizę awaryjności. Wzrastająca ilość awarii była czynnikiem decydującym w ocenie stanu technicznego linii kablowych. Rozwój aparatury pomiarowej pozwala na dokonywanie nowych badań w eksploatowanych sieciach kablowych, poszerzając wiedzę o ich stanie technicznym. Dzięki uzyskanym informacjom można zmienić dotychczasowy sposób działania i zarządzania siecią kablową. Można go oprzeć o proces badania stanu technicznego izolacji poszczególnych elementów linii kablowej. Do takich nowoczesnych metod pomiarowych można zaliczyć pomiar wyładowań niezupełnych.
Źródło:
Acta Energetica; 2009, 1; 111-120
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyspieszenie na budowie mostu Rędzińskiego - zmiany projektowe i organizacyjne
Autorzy:
Bryll, M.
Powiązania:
https://bibliotekanauki.pl/articles/365532.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
most
most podwieszony
most Rędziński
Redzinski Bridge
Wrocław
bridge
cable-stayed bridge
Opis:
Na początek garść faktów. Most Rędziński we Wrocławiu zajmuje 18 miejsce na świecie w kategorii największych obiektów mostowych podwieszonych do jednego pylonu. W klasie budowli betonowych jest to czwarty największy most betonowy świata. W Polsce nie ma wyższego pylonu niż 122-metrowy, ani też dłuższej przeprawy.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 6; 60-62
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problems of Connecting Wind Farms to the Power System with HV Cables
Problemy przyłączania farm wiatrowych do systemu elektroenergetycznego z wykorzystaniem kabli WN
Autorzy:
Klucznik, J.
Powiązania:
https://bibliotekanauki.pl/articles/397688.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
linie kablowe
farma wiatrowa
moc bierna
cable lines
wind farm
reactive power
Opis:
This paper presents problems caused by connecting wind farms to a power system with high voltage cables. The author highlights possible problems with reactive power compensation, depending on the arrangement of the shunt reactor connection and settings of control systems for reactive power and voltage of the wind farm. The paper also discusses issues of increasing active power losses caused by a shunt reactor installation.
Artykuł prezentuje problemy, jakie rodzi przyłączanie farm wiatrowych do systemu elektroenergetycznego za pomocą kabli wysokiego napięcia. Autor wskazuje możliwe problemy z kompensacją mocy biernej, w zależności od sposobu przyłączenia dławika kompensacyjnego i nastawień układów regulacji mocy biernej oraz napięcia farmy wiatrowej. Artykuł porusza też zagadnienia zwiększenia strat mocy czynnej powodowanych instalacją dławików kompensacyjnych.
Źródło:
Acta Energetica; 2016, 2; 118-122
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie Metody Elementów Skończonych w obliczeniach statycznych konstrukcji cięgnowych
Application of Finite Elements Method in static analysis of cable structures
Autorzy:
Ruchwa, M.
Matuszkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/211221.pdf
Data publikacji:
2010
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
statyka
konstrukcje cięgnowe
metoda elementów skończonych
static
cable structures
finite elements method
Opis:
W publikacji zwrócono uwagę na możliwości Metody Elementów Skończonych (MES) w nieliniowej analizie statycznej konstrukcji cięgnowych oraz problemy pojawiające się w trakcie obliczeń. Zawarto informacje pomocne w modelowaniu i rozwiązywaniu tego typu zadań przy pomocy oprogramowania ABAQUS. Porównano rezultaty numeryczne uzyskiwane za pomocą MES z dostępnymi w literaturze wynikami ścisłych i przybliżonych obliczeń analitycznych. Przeliczeniu podlegały przykłady dotyczące analizy pojedynczych cięgien o różnych wartościach zwisu, różnych wartościach kąta nachylenia cięciwy oraz różnych sposobach obciążenia. Analizowano także przykład konstrukcji złożonej, w obliczeniach której pojawiły się wymienione wcześniej cechy oraz dodatkowo uwzględniono współpracę wielu cięgien z elementami typowej konstrukcji prętowej. Rozwiązując zadania Metodą Elementów Skończonych, zastosowano podstawowe rodzaje elementów, liniowosprężysty opis materiałowy, różnego typu obciążenia statyczne, uwzględniono również zwis oraz sprężanie cięgien, nieliniowości geometryczne oraz współpracę cięgien z innymi elementami konstrukcyjnymi. Zwrócono uwagę na zgodności oraz różnice wyników obliczeń MES i obliczeń analitycznych, dotyczące rozkładu przemieszczeń oraz sił przekrojowych, uzyskiwane w podstawowych oraz złożonych przykładach analiz.
The Finite Elements Method allows for comprehensive structural analysis, however, in the case of cable structures its potential is not fully used due to problems in arriving at convergence of solutions and pertaining to compatibility of FEM and analytical calculation results. In this paper, numerical results, originating from the Finite Elements Method with the analytical calculation results, in terms of nonlinear structural analysis, were compared and conclusions that can be useful in numerical handling of such type problems were formulated. Examples pertaining to the analysis of single cables of variable slack values, bowstring inclination angle and loading methods were being calculated. Also an example of a complex structure in calculation of which the previously mentioned features appeared was analysed; furthermore, cooperation between many cables with traditional rod structure elements was considered. Solving the problems through application of the Finite Elements Method, primary types of finite elements, linear elastic relationship, various static loads as well as slack and cable prestressing, geometric nonlinearity, cooperation between cable elements and other structural elements and also typical incremental methods used in static analysis, were applied. The calculation tool used here was ABAQUS software. In the summary, attention was focused on conformities and differences in FEM and analytical calculation results regarding distribution of the displacements and cross-sectional forces obtained in the basic and complex examples of analyses.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2010, 59, 4; 363-377
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Damping of the waves motion in a span by the active distributed force
Tłumienie ruchu fal w przęśle za pomocą aktywnego obciążenia ciągłego
Autorzy:
Łatas, W.
Powiązania:
https://bibliotekanauki.pl/articles/368844.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
drgania przewodów
fale biegnące
metody aktywne
cable vibration
running waves
active methods
Opis:
In the paper the problem of optimal damping of the waves - traveling along the cable in a span and reflected - by the active distributed damping force segment located near the support is analyzed. The string equation is chosen as a model of the vibrating cable. As an objective function of the optimization problem the energy dissipated by the damper force is assumed. The damping algorithm is based upon the expression for the optimal concentrated damping force. The distributed force is assumed to be proportional to the component of the cable velocity resulting from the superposed motion of the original running and the original reflected waves. The original running waves are assumed in the form of packet waves with amplitude modulation. Illustrative numerical results demonstrating the optimal damping coefficients are included.
W pracy przedstawiono rozważania dotyczące optymalnego tłumienia fal - biegnących wzdłuż liny w przęśle i odbijanych - za pomocą aktywnego ciągłego pasma tłumiącego umiejscowionego w pobliżu podpory. Ruch liny opisano liniowym równaniem struny. Za funkcję celu przyjęto energię rozproszoną przez tłumik. Wykorzystując wyrażenie na optymalną skupioną siłę tłumiącą przyjęto ciągłe obciążenie tłumiące w paśmie proporcjonalne do składowej prędkości przekroju liny pochodzącej od sumy pierwotnej fali padającej oraz pierwotnej fali odbitej. Fale biegnące w linach przyjęto w postaci paczek falowych z modulowaną amplitudą. Przedstawiono wyniki obliczeń numerycznych optymalnych współczynników tłumienia w paśmie.
Źródło:
Mechanics and Control; 2010, 29, 1; 22-25
2083-6759
2300-7079
Pojawia się w:
Mechanics and Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zjawiska naskórkowości na zespolony współczynnik propagacji fali elektromagnetycznej w kablu współosiowym
Influence of skin effect on complex propagation coefficient of the electromagnetic wave in a coaxial cable
Autorzy:
Bugajska, A.
Powiązania:
https://bibliotekanauki.pl/articles/153360.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
współczynnik propagacji
zjawisko naskórkowości
kabel współosiowy
propagation coefficient
skin effect
coaxial cable
Opis:
W artykule pokazano, że rezystancja jak również indukcyjność całkowita elektroenergetycznego kabla współosiowego zależą od zjawiska naskórkowości. W szczególności rozpatrzono wpływ tego zjawiska na zmianę współczynnika propagacji, a więc również współczynników tłumienia i opóźnienia fazowego w zależności od częstotliwości. Współczynniki te określają odpowiednio tłumienie i prędkość propagacji fali w współosiowym kablu elektroenergetycznym przy lokalizacji miejsca jego uszkodzenia metodami falowymi.
The paper shows that resistance and total inductance of a coaxial cable depend on the skin effect. Special consideration is given to the influence of this effect on the propagation coefficient, thus also the attenuation and phase lag coefficient in relation to frequency. Those coefficients determine respectively attenuation and speed of wave propagation in a heavy current coaxial cable when locating the fault position with use of wave detection methods. The paper shows that for high frequencies the attenuation coefficient value depends mainly on the total cable resistance and can be about 55 times greater than its value calculated without taking into consideration the skin effect. The phase lag coefficient depends primarily on the coaxial cable total inductance and decreases, similarly as the total inductance, with the increase in frequency. This decrease can reach about 25 % of the coefficient value calculated without taking into consideration the skin effect.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 12, 12; 1442-1444
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zjawiska naskórkowości na impedancję wejściową kabla współosiowego w stanie jałowym i w stanie zwarcia
The influence of the skin effect on input impedance in a coaxial cable in a no-load state and a short-circuit state
Autorzy:
Bugajska, A.
Powiązania:
https://bibliotekanauki.pl/articles/159024.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
kabel współosiowy
impedancja wejściowa
zjawisko naskórkowości
skin effect
coaxial cable
input impedance
Opis:
W artykule przedstawiono wpływ zjawiska naskórkowości na impedancję wejściową kabla współosiowego w stanie jałowym i zwarcia, przy uwzględnieniu jakościowego i ilościowego wpływu tego zjawiska na całkowitą impedancję jednostkową kabla współosiowego,czyli na rezystancje, indukcyjności własne żyły i ekranu,a także na indukcyjność wzajemną między nimi. Dla wybranej częstotliwości obliczenia wykonano dla kabla typu YHKXS zmieniając grubość jego izolacji i ekranu.
The article presents the influence of the skin effect on input impedance of a coaxial cable in a no-load state and a short circuit state, when taking into account qualitative and quantitative influence of this effect on total unit impedance of a coaxial cable, that is resistance, self inductance of the conductor of the cable and the cable screen, and on the mutual inductance between them. The calculations have been performed for the type YHKXS cable assuming: wire radius R1 = 0.01 m, relative thickness of the cable insulation characterized by the parameter [WZÓR], whereas the relative thickness of the screen by the parameter [WZÓR] (R- interior radius of the cable screen, R2 - exterior radius of the cable screen). Assumed frequency value was f = 100 kHz. With a given load impedance, the input impedance of a coaxial cable depends on the skin effect. Figures 2, 3, 5 and 6 show that with the increase of the line's length, the maximum value of the input impedance module in no-load state (Fig. 2, 3) as well as in shortcircuited state (Fig. 5, 6) decrease, moreover, the amplitudes of input impedance module, after taking into consideration the skin effect, are considerably smaller than without accounting for this effect. The wavelength in a coaxial cable without taking into consideration the skin effect equals [WZÓR] and is smaller than the wavelength when taking the mentioned effect into consideration. In that case [WZÓR]. It is the result of the fact, that the phase lag coefficient depends primarily on total inductance of a coaxial cable chich causes its decrease, as well as of total inductance, with the increase of frequency.
Źródło:
Prace Instytutu Elektrotechniki; 2011, 252; 5-18
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of induced voltages and power losses in high voltage power cables for selected methods of cables sheaths bonding
Analiza napięć indukowanych i strat mocy w kablach elektroenergetycznych wysokiego napięcia dla wybranych sposobów uziemienia żył powrotnych
Autorzy:
Czapp, S.
Dobrzyński, K.
Klucznik, J.
Lubośny, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397047.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
power cable
induced voltage
power loss
kabel elektroenergetyczny
napięcie indukowane
strata mocy
Opis:
Power is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s outer non-conductive sheath. These voltages depend on the earthing/bonding of the cable’s sheaths, and on the cable configuration. These voltages induce currents, which, in turn, cause additional power losses in the cable. The article presents multivariate analysis of the voltages induced in a selected cable line in steadystate condition. Single-point bonding of sheaths has been discussed, as well as their both-ends bonding, transposition, and transposition of cores (conductors). For each case, the losses of active power in this line have been calculated.
Streszczenie Dostarczanie mocy do centrów miast coraz częściej odbywa się z wykorzystaniem linii kablowych o napięciu 110 kV. To dogodny sposób zasilania, a praktycznie jedyny możliwy w przypadku gęstej zabudowy miejskiej. Kable wysokiego napięcia zawierają współosiową żyłę powrotną, w której podczas normalnej pracy oraz w stanach zakłóceniowych (podczas zwarć) mogą indukować się znaczne napięcia względem ziemi, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu uziemienia żył powrotnych kabli oraz konfiguracji kabli. Konsekwencją napięć indukowanych są prądy indukowane, a te z kolei są przyczyną dodatkowych strat mocy w kablach. W artykule przedstawiono wielowariantową analizę napięć indukowanych w wybranej linii kablowej. Rozpatrzono uziemienie jednostronne żył powrotnych, uziemienie dwustronne żył powrotnych, transpozycję żył powrotnych oraz transpozycję żył roboczych. Dla każdego z przypadków obliczono straty mocy czynnej w tej linii.
Źródło:
Acta Energetica; 2017, 2; 29-35
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and numerical studies of inclined cables: free and parametrically-forced vibrations
Doświadczalne i numeryczne badania obciążonych lin ukośnych: drgania swobodne i wymuszone parametrycznie
Autorzy:
Rega, G.
Srinil, N.
Alaggio, R.
Powiązania:
https://bibliotekanauki.pl/articles/280929.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
symulacje numeryczne
liny ukośne
inclined cable
frequency avoidance
hybrid modes
numerical simulation
Opis:
Because of few experimental studies in the inclined cable literature, this paper is aimed at experimental modelling and investigating the linear free and nonlinear forced vibrations of sagged inclined cables, by discussing the relevant outcomes in the background of theoretical and numerical achievements. Attention is paid to the identification of cable hybrid modes due to system asymmetry, which gives rise to an avoidance phenomenon in the natural frequency spectrum, and to the investigation of some typical 3-D nonlinear dynamics involving the simultaneous parametric/external excitation due to a harmonically time-varying support movement. Large-amplitude out-of-plane/in-plane multi-modal interactions due to non-planar/planar internal resonances are experimentally observed and complemented by space-time numerical simulation of the associated, geometrically nonlinear, partial-differential equations of parametrically-forced cable motion. Overall, the experimental and numerical results highlight the fundamental linear/nonlinear dynamic characteristics of inclined cables, and the crucial role played by the asymmetry induced by cable inclination, in addition to the significant effects of cable sag and dynamic extensibility.
Ubogie opracowania literaturowe dotyczące badań eksperymentalnych ukośnych lin przenoszących obciążenie skłoniły autorów tej pracy do zajęcia się problemem mo- delowania liniowych i nieliniowych drgań ugiętych lin ukośnych w oparciu o dyskusję otrzymanych wyników badań teoretycznych i numerycznych. Uwagę skoncentrowano na identyfikacji hybrydowych postaci drgań własnych lin wywołanych asymetrią, która prowadzi do tzw. zjawiska unikania częstości dającego się zaobserwować w spektrum układu. Dokonano analizy trójwymiarowego układu z uwzględnieniem jednoczesnego działania parametrycznego/zewnętrznego wymuszenia ruchem harmonicznym punktu zamocowania liny. Wielomodalne płaskie i niepłaskie wzajemne oddziaływania o dużej amplitudzie wywołane płaskimi i niepłaskimi rezonansami wewnętrznymi potwierdzono doświadczalnie i przewidziano w drodze symulacji numerycznych cząstkowych różniczkowych równań ruchu liny z nieliniowością geometryczną przy wzbudzeniu para- metrycznym. Otrzymane rezultaty badań doświadczalnych i numerycznych uwypukliły charakterystyczne cechy liniowej/nieliniowej dynamiki lin ukośnych ze szczególnym podkreśleniem roli asymetrii w układzie spowodowanej niezerowym kątem nachylenia liny, towarzyszącej pozostałym efektom, takim jak zwis i dynamiczna rozszerzalność.
Źródło:
Journal of Theoretical and Applied Mechanics; 2008, 46, 3; 621-640
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie technik światłowodowych w kolejnictwie
Use of fiber optic technology in railway engineering
Autorzy:
Trzoński, K.
Powiązania:
https://bibliotekanauki.pl/articles/248410.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
światłowód
włókno optyczne
kabel światłowodowy
fiber optic
optical fiber
fiber optic cable
Opis:
W referacie przybliżono problematykę wykorzystania technik światłowodowych. Opisano budowę światłowodu i zasadę działania, a także scharakteryzowano jego przeznaczenie. Wymieniono zalety kabli światłowodowych oraz przedstawiono możliwości ich zastosowania.
The paper presents the problem of fiber optic technique usage. The construction of fiber optic cable and the rules of its operation as well as the purposes of its usage have been discussed, The advantages of optic fiber cables and the possibilities of their application have been listed.
Źródło:
Zeszyty Naukowo-Techniczne Stowarzyszenia Inżynierów i Techników Komunikacji w Krakowie. Seria: Materiały Konferencyjne; 2013, 3(102); 499-505
1231-9171
Pojawia się w:
Zeszyty Naukowo-Techniczne Stowarzyszenia Inżynierów i Techników Komunikacji w Krakowie. Seria: Materiały Konferencyjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of influence of the type line supplying nonlinear load on deformation of voltage and current in the power system
Autorzy:
Bolkowski, S.
Brociek, W.
Wilanowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/97618.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
deformations of voltage and current
frequency characteristics
passive filters
overhead and cable lines
Opis:
The results of simulation tests concerning the cooperation of the nonlinear load with the power system are presented. In numerical experiments we have taken data from the real systems, including the cable and overhead lines. In practice the nonlinear load of high power may be supplied by the overhead or cable lines. The paper presents the comparative analysis, how the applied type of the line influences the level of distortion of the voltages and currents in the power system. The values of the higher harmonics of the voltages and currents as well as THD have been determined in the paper. These values have been estimated for the beginning and ending terminals of the overhead and cable lines supplying the nonlinear load of the inductive character concerning the cooperation of the filtering compensating device and the nonlinear load of high power. All experiments have been performed using MicroCap-8 program. In the paper we have included he exemplary results of the numerical calculations.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 11-23
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienie obliczania zmęczeniowej trwałości projektowej cięgieł nośnych skipu górniczego
Autorzy:
Płachno, M.
Powiązania:
https://bibliotekanauki.pl/articles/305121.pdf
Data publikacji:
2018
Wydawca:
Wydawnictwo Druk-Art
Tematy:
skip górniczy
naczynie wyciągowe
mechanizacja górnictwa
extraction vessel
mechanization of mining
support cable
Opis:
Przy projektowaniu skipów górniczych wykonuje się obliczenia zmęczeniowe cięgieł nośnych, dotyczące zmiennych obciążeń statycznych. Mimo to uszkodzenia zmęczeniowe cięgieł, zwłaszcza przy skipach o dużej ładowności, nie są sporadyczne, czego główną przyczyną są drgania poprzeczne skipów związane z ich użytkowaniem w szybach. Te drgania są bardzo trudne do redukcji w ruchu szybowym, w związku z czym użytkownicy skipów górniczych oczekują, aby projektowe obliczenia zmęczeniowe cięgieł dotyczyły także takich drgań. Jednak, mimo podejmowanych prób, nie dopracowano się dotychczas wiarygodnej metody oczekiwanych obliczeń, która jest nadal aktualnym wyzwaniem dla naukowo-badawczego zaplecza przemysłu wydobywczego. Niniejsza praca dotyczy tego wyzwania, a inspiracją do jego podjęcia były doświadczenia poznawcze uzyskane w diagnostycznych badaniach [1] naprężeń w cięgłach skipów, przedstawione w poprzednim rozdziale tej monografii.
When designing mining skips, fatigue calculations of carrying pull rods for static load variables are per-formed. In spite of this, the fatigue failures of carrying pull rods, especially in high payload skips, is not sporadic, which is mainly due to the transverse vibrations of the skips associated with their use in the shafts. These vibrations are very difficult to reduce in shaft motion, so users of mining skips expect that the fatigue design of tie rods also involves such vibrations. However, in spite of the attempts ma-de, the reliable method of expected calculations has not yet been developed, which is still a current challenge for the mining industry’s research and development background. This paper deals with this challenge, and the inspiration for it was the cognitive experience gained in diagnostic studies [1] of stresses in carrying pull rods, presented in the previous chapter of this monograph.
Źródło:
Napędy i Sterowanie; 2018, 20, 2; 64-75
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mosty Seulu
Autorzy:
Dąbrowiecki, K.
Powiązania:
https://bibliotekanauki.pl/articles/364114.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
most
most Incheon
most podwieszany
Seul
bridge
cable-stayed bridge
Incheon bridge
Seoul
Opis:
Seul ma niezwykle malownicze położenie. Rozsiany jest po licznych wzgórzach, zboczach otaczających gór, rozległych dolinach, i rozciągnięty po obu stronach rzeki Han. Zdewastowany długoletnią okupacją japońską (1910-1945), zniszczony podczas wojny koreańskiej (1950-1953) i odbudowany dzięki pomocy zagranicznej, jest świadectwem niezwykle dynamicznego rozwoju i sukcesu ekonomicznego Korei w ostatnich 30 latach. Nad miastem, na górze w parku Namsan, w samym środku tej ogromnej aglomeracji, wznosi się wieża Seulu, widoczny symbol nowoczesności, będący zarazem jedną z atrakcji turystycznych i znakomitym punktem widokowym na tętniące poniżej miasto i niezbyt ruchliwą rzekę Han z 28 mostami.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 6; 38-41
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Documentation of the Location and Directions of Stay - Cables Pipes in Road Bridge Pylons
Autorzy:
Jóźwik, M.
Jaśkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/224489.pdf
Data publikacji:
2007
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
most
wspornik mostu
pomiary geodezyjne
bridge
bridge pylon
cable-stay pipe
engineering surveying
Źródło:
Reports on Geodesy; 2007, z. 1/82; 129-134
0867-3179
Pojawia się w:
Reports on Geodesy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Forma architektoniczna obiektów o konstrukcji cięgnowej
Architectural form of cable-supported structures
Autorzy:
Tofil, Jolanta
Powiązania:
https://bibliotekanauki.pl/articles/1848257.pdf
Data publikacji:
2021
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
konstrukcja cięgnowa
forma architektoniczna
prawdziwość
struktura
cable-supported structure
architectural form
verity
structure
Opis:
Mario Salvadori zaznacza, że struktura może istnieć bez architektury – jako przykład wskazuje maszyny - a architektura nie może istnieć bez struktury [14]. Za zasadnością podjętych rozważań może przemawiać przekonanie, iż elementy konstrukcji cięgnowej odpowiedzialne za statykę obiektów nie stanowią jedynie strukturalnej osnowy, lecz odgrywają istotną rolę w określaniu formy owej architektury. Metody użyte w badaniach nad tym zagadnieniem opierają się głównie na przeglądzie literatury, obserwacjach własnych oraz wielokrotnym studium przypadku.
Mario Salvadori states that structure can exist without architecture, giving machines as examples but architecture cannot exist without structure [1]. The reasoning behind the considerations in the article may be the belief that the elements of the cable-supported structure responsible for the statics of objects are not only the structural matrix, but play an important role in determining the form of the architecture. The methods used in the studies on this issue are mainly based on a literature review, own observations and multiple case studies.
Źródło:
Builder; 2021, 25, 7; 55-57
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified ground support with alternative fill material for ground control at munsar underground manganese mine of MOIL Limited, India
Autorzy:
Manekar, Ganesh
Shome, Dipankar
Chaudhari, Mukund
Powiązania:
https://bibliotekanauki.pl/articles/2064378.pdf
Data publikacji:
2019
Wydawca:
STE GROUP
Tematy:
cable bolting
heat treatment
overburden
RMR
stowing
kotwienie kabli
obróbka cieplna
nadkład
podsadzka
Opis:
MOIL Limited is operating 7 underground and 3 opencast mines in central India and producing annually more than 1.3 million tonnes of various grades of manganese ore. The underground mines are operating at shallow - 90 m at Munsar mine to moderate - 353 m at Balaghat mine below the surface with horizontal cut and fill (HCF) or its variant method of stoping with post filling by hydraulic sand stowing. The Munsar mine is being worked underground since 1903. The opencast mining is presently stopped. The ore body below the opencast quarry is geological continuity of the area excavated in past by opencast method of mining. The underground mining is done through the adit in three levels i.e. 270’L, 220’L, 170’L and by incline in western part of the property at 70’L. The horizontal drift development has been developed in the manganese ore body with sill drive of 5 m above the sill pillar in lower level at 70’L and barrier pillar of 5 m thickness is left for protection of upper level at 170’L. Valuable mineral has been locked in sill pillar and therefore rock mechanics investigations have been carried out. On the basis of study now the drift development has been carried out in footwall rock at 70’L, (-) 30’L and below levels and it has improved the minable manganese ore by about 20%. In this modified HCF stope design, an alternative fill material in place of sand, which has been developed in house by use of overburden (OB) material after treatment, has been used for hydraulic stowing. The experimental trials find out that the alternative fill material of OB is more compact and forms a non-expansion floor for the men and machines in the stope. This will certainly help in the introduction of mobile underground mining equipment for drilling in the stopes and mechanical mucking, transportation and loading of the ROM. The paper presents rock mechanics investigations and future use of alternative fill material of overburden material after heat treatment for better safety and productivity at Munsar Mine of MOIL.
Źródło:
New Trends in Production Engineering; 2019, 2, 1; 69--77
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ roztworu środka pianotwórczego na funkcjonowanie przewodów ognioodpornych w tynku w warunkach pożaru
The Influence of Fire Foam Water Solution on Fire – Resistant Cables Operation in Fire Conditions
Autorzy:
Chybowski, R.
Kustra, P.
Ptak, S.
Powiązania:
https://bibliotekanauki.pl/articles/136292.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
przewody ognioodporne
elektroenergetyczne zagrożenia pożarowe
środek pianotwórczy
fire resistant cable
electrical fire safety
Opis:
W artykule przedstawiono wyniki badań wpływu zawilgocenia tynku wodą oraz roztworem pianotwórczym na funkcjonowanie przewodów ognioodpornych w warunkach pożaru.
The article describes and discusses the research results concerning the influence of fire foam water solution on fire – resistant cables operation in fire conditions. Dampen plaster enhances the danger of electric shock of the firemen during operations, as the leakage current increases, when fire foam solution is used. Mica, if used as wire insulation, reduces the leakage current.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2013, 1, 45; 55-60
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polska technologia badania lin stalowych najpoważniejszych urządzeń linowych na świecie
Polish technology for testing wire ropes of the largest rope devices in the world
Autorzy:
Martyna, R.
Martyna, M.
Powiązania:
https://bibliotekanauki.pl/articles/107752.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
NDE liny mostów
NDE liny dźwigów
NDT NDE cable bridge
NDT NDE lift rope
Opis:
W 2016 roku minęło 70 lat od rozpoczęcia w Polsce prac przez profesorów AG H L. Szklarskiego, M. Jerzewskiego, Z. Kaweckiego, a następnie J. Stachurskiego nad zastosowaniem metody magnetycznej pola rozproszenia MFL (Magnetic Flux Leakage) do badania lin stalowych. Również w tym roku minęło 40 lat pracy Romana Martyny nad rozwojem metody MRT (Magnetic Rope Testing). Młode pokolenie implementowało do technologii LRM-NDE badania lin stalowych najnowsze osiągnięcia elektroniki i informatyki. W niniejszym artykule przedstawiono wymagania stawiane w badaniu lin stalowych w różnych warunkach, a także na zaawansowanie proponowanego systemu. Udoskonalone rozwiązania sprzętowe i programowe systemu LRM®XXI umożliwiły zwiększenie skuteczności i dokładność metody MRT badania lin stalowych, obrazowanie badania w czasie rzeczywistym na ekranie komputera, porównanie wyników kolejnych badań, oraz możliwości analizy i prezentacji wyników badań.
2016 was an anniversary year - 70 years since AG H professors L. Szklarski, M. Jeżewski, Z. Kawecki and J. Stachurski started developing the Polish method of Magnetic Flux Leakage techniques (MFL) testing steel-wire ropes. This year also marks 40 years of personal contribution of Roman Martyna in the area of the development of Magnetic Rope Testing (MRT ). The latest advances in electronics and information technology has been implemented to LRM-NDE steel wire rope technology, which has led to the innovative LRM®XXI Rope Diagnostic System being utilized by numerous national and international evaluation experts. In this paper the wire-rope testing requirements under different conditions as well the advancement of the proposed system are presented. The outworked hardware and software solutions improves the possibility and accuracy of proposed MRT method of testing steel ropes. The software gives users the new possibility to proceed rapid analysis and present test results, which are shown on the computer screen in real time. Finally the inspection of various large constructions is presented and discussed.
Źródło:
Badania Nieniszczące i Diagnostyka; 2017, 4; 11-16
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and modeling of an exoskeleton torque sensor
Autorzy:
Herbin, P.
Powiązania:
https://bibliotekanauki.pl/articles/135222.pdf
Data publikacji:
2017
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
exoskeleton
torque sensor
FEM analysis
closed loop cable conduit system
strain gauge
wearable robots
Opis:
Controlling the upper limb with force feedback requires the continuous measurement of multiple values, so it is necessary to use a specific measuring system. The position of the joints and the torque produced by the drives are the basic feedbacks necessary for control. Measurement of the joint positions does not cause complications, while measurement of the driving torque is much more complex. This article describes the methods of implementing an exoskeleton drive system through a closed loop conduit system based on Bowden cables, and the integration of a torque sensor within the wheel of the exoskeleton. The integration of the sensor within a mechanical part of the construction of the exoskeleton is the main advantage of the developed sensor because it does not affect the dynamics of the exoskeleton. This article presents the process of designing, calibrating and validating the proposed link wheel torque sensor.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2017, 51 (123); 89-94
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki pracy otoczenia sieciowego a praca łącza HVDC SwePol Link
Power network operating conditions vs HVDC SwePol Link operation
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/266869.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
łącze HVDC
technologia LCC
przewrót komutacyjny
HVDC cable line
Line Commutated Converters
commutation failure
Opis:
W pracy łącza HVDC SwePol Link rejestruje się zakłócenia związane z wyzwalaną sieciowo komutacją tyrystorów (przewroty komutacyjne) powstające w trakcie importu energii elektrycznej do Polski. Przewrót komutacyjny może prowadzić do wyłączenia łącza i w efekcie do ograniczeń w realizacji wymiany mocy między Polską i Szwecją. Dodatkowym skutkiem wyłączenia łącza mogą być defekty techniczne. W artykule przedstawiono wyniki przeprowadzonej analizy przyczynowo-skutkowej wpływu funkcjonowania sieci zamkniętej w północnym rejonie Krajowego Systemu Elektroenergetycznego na zakłócenia w pracy łącza HVDC SwePol Link.
The HVDC SwePol Link allows the power and energy exchange between Poland and Sweden. Disturbances of HVDC SwePol Link operation occur during energy import to Poland. The connection between Poland and Sweden was establish in 2000 and consist of a bipolar HVDC cable line and two AC/DC converter stations, one in Slupsk (the Polish power system side) and the second one in Stärnö (the Swedish power system side). The reason of identified disturbances was events in polish power network, which can cause commutation failure. That commutation failure could lead to switching off the HVDC SwePol Link and additionally resulting in unexpected limitation of power exchange between Poland and Sweden. The paper will present results of cause-and-effect analysis of Polish power system in terms of interference with the HVDC SwePol Link. Events leading to the occurrence of commutation failure will be described as well as impact assessment of different AC power system operation states in network-area of Slupsk substation. Commutation failure phenomenon in some cases caused some damages. According to that facts an important element of the paper will be a quantitative description of the commutation failure that occur during the lifetime of the HVDC SwePol link.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 85-83
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cross-Bonding of MV Cable Lines for Energy Losses Decrease
Krzyżowanie żył powrotnych w liniach kablowych SN w celu zmniejszenia strat energii czynnej
Autorzy:
Dobrzyński, Krzysztof
Lubośny, Zbigniew
Klucznik, Jacek
Falkowski, Dominik
Grala, Janusz
Noske, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/952878.pdf
Data publikacji:
2019
Wydawca:
ENERGA
Tematy:
cross bonding
MV cable line
energy losses
krzyżowanie żył
linie kablowe SN
straty energii
Opis:
Currently, almost all medium voltage cable lines (MV) operate with the return wires earthed at both ends of the cable. Such a way of operation causes that during normal states of operation as well as during disturbances, e.g. short-circuits, in the return wires induce currents whose values mainly depend on the currents flowing in the phase wires. These currents in normal operating states are a source of additional energy losses incurred in the MV cables. The effect can be decreased by the return wires cross-bonding or the phase wires transposition. The paper discusses the potential effects that can be achieved by use of the return wires cross-bonding or the phase wires transposition in the domestic grids.
Aktualnie u prawie wszystkich polskich operatorów sieci dystrybucyjnej (OSD) linie kablowe średniego napięcia (SN) pracują z żyłami powrotnymi uziemionymi na początku i na końcu linii. Taki układ pracy powoduje, że podczas stanów normalnych, jak i podczas zwarć, indukują się w żyłach powrotnych prądy, których wartości zależą głównie od prądów płynących w żyłach roboczych. Prądy te w stanach normalnych są źródłem dodatkowych strat przesyłowych ponoszonych w kablach SN. Artykuł zawiera dyskusję nad zasadnością stosowania transpozycji żył powrotnych lub żył roboczych w warunkach krajowych.
Źródło:
Acta Energetica; 2019, 2; 47-53
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical calculations of surges caused by direct lightning strike to underground intrusion detection system
Autorzy:
Aniserowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/200287.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lightning
transients
overvoltages
analytical modeling
underground cable
błyskawica
transjenty
przepięcia
modelowanie analityczne
kabel podziemny
Opis:
The paper presents an analysis of overvoltages caused by a direct lightning strike in intrusion detection system equipped with underground radiating cable sensors. Waveforms of currents and voltages in the system components are calculated using analytical formulas basing on a transmission-line model in the frequency domain. The time-domain waveforms are computed using the inverse fast Fourier transform (IFFT). Three network configurations of the intrusion detection system are analyzed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 2; 263-270
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koleje linowe jako element promocji miast
Ropeways in cities promotion
Autorzy:
Magiera, T.
Powiązania:
https://bibliotekanauki.pl/articles/193369.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
miejskie koleje linowe
promocja miasta
cable propelled transit
ropeways
promotion of cities
Opis:
Analiza funkcji promocyjnych kolei linowych miast . lub regionów. Charakterystyka dwóch rozwiązań transportu linowego, które poprzez nietypowe rozwiązania techniczne stały się atrakcjami turystycznymi – Skyview w Sztokholmie i Jewel Box Cable Car w Singapurze.
Analysis of promotion functions of ropeways in cities or regions. Charakteristics of two examples of cable transport means which have become tourist attractions thanks non– standard technical solutions – Skyview in Stockholm and Jewel Box Cable Car in Singapore.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 25-27
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miejska kolej linowa dla Kłodzka
The concept of reversible ropeway in Klodzko
Autorzy:
Rokita, T.
Wójcik, M.
Powiązania:
https://bibliotekanauki.pl/articles/953085.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
miejskie koleje linowe
kolej dwulinowa
cable propelled transit
bicable ropeway
reversible ropeway
Opis:
Uwarunkowania możliwości zastosowania miejskiej napowietrznej kolei linowej w Kłodzku. Charakterystyka zaproponowanego rozwiązania kolei dwulinowej o ruchu wahadłowym. Wyniki obliczeń wykonanych dla zaproponowanego rozwiązania. Wizualizacje architektoniczne części mechanicznej stacji projektowanej kolei linowej.
Conditions for implementation of an aerial ropeway in Kłodzko. The characteristics of bicable reversible ropeway and results of the project calculations. Architectural visualizations of mechanical parts of the designed station building.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 10-12
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa kolej linowa dla Wojewódzkiego Parku Kultury i Wypoczynku w Chorzowie
Project of the new gondola ropeway in the Voivodship Park of Culture and Recreation in Chorzow
Autorzy:
Rokita, T.
Wójcik, M.
Powiązania:
https://bibliotekanauki.pl/articles/953086.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
miejskie koleje linowe
kolej krzesełkowo-kabinowa
mix-gondola
cable propelled transit
ropeways
Opis:
Koncepcja nowej kolei linowej dla Wojewódzkiego Parku Kultury i Wypoczynku w Chorzowie w miejsce zlikwidowanej kolei ELKA. Wymagania stawiane miejskim kolejom linowym widokowo‑turystycznym. Charakterystyka zaproponowanej kolei krzesełkowo‑kabinowej. Wizualizacje architektoniczne stacji projektowanej kolei.
The concept of a new mix-gondola ropeway system replacing ELKA chairlift in the Voivodship Park of Culture and Recreation. Technical requirements for cable propelled transit in cities together with the profile of the mix-gondola system as a showplace and viewing attraction. Architectural visualizations of the stations.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 3-5, 12
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pilot implementation of the on-line partial discharge monitoring system for heads of the high voltage cable lines
Autorzy:
Konarski, Michał
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/220896.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cable lines diagnostics
partial discharges
unconventional methods of partial discharges measurement
UHF electromagnetic method
Opis:
The article presents the assumptions, characteristics and description of the implementation of a pilot system for on-line monitoring of partial discharges in heads of the high-voltage cable lines. The main purpose of the implementation was to increase the reliability of cable line heads by equipping them with a system of continuous assessment of technical condition with direct transmission of measurement data and alarms to the SCADA system. In order to achieve the assumed goal, unconventional methods for measuring partial discharges were used, the application of which does not require disconnecting the line from the voltage. The implementation was carried out on an active 110 kV high voltage cable line in the area of activity of one of the Distribution System Operators.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 373-382
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
25 lat stosowania technologii bezwykopowej wymiany przewodów podziemnych w Polsce
Autorzy:
Kuliczkowski, A.
Kuliczkowska, E.
Nogaj, S.
Powiązania:
https://bibliotekanauki.pl/articles/364523.pdf
Data publikacji:
2018
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
technologia bezwykopowa
geotechnika
przewód
kanalizacja
wodociągi
no-dig technology
geotechnica
cable
sewers
water pipelines
Opis:
Technologie bezwykopowej wymiany przewodów infrastruktury podziemnej na dużą skalę zaczęto stosować wraz z opracowaniem technologii Berstliningu (Pipe Bursting), umożliwiającej bezwykopową wymianę przewodów z pozostawieniem zniszczonego starego przewodu w gruncie po zewnętrznej stronie nowo wprowadzonego przewodu.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2018, 2; 96-99
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of deep-water concretions by a spiral method
Autorzy:
Sukach, M.
Powiązania:
https://bibliotekanauki.pl/articles/411197.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
floating complex
iron-manganese minerals
spiral method of extraction
trajectory of motion
hose-cable
Opis:
These features occurrence and distribution of deep-sea nodules. A development of the bottom of fossil spiral manner. Scheme is shown floating and complex trajectory carriage bottom of the unit. The basic technological calculation unit that moves around the base module and given recommendations on its use.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2016, 5, 4; 49-54
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Selection of Compensation Devices Determining the Reactive Power Balance of Wind Farms
Autorzy:
Gryniewicz-Jaworska, Michalina
Powiązania:
https://bibliotekanauki.pl/articles/103365.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
reactive power compensation
wind farms
cable lines
kompensacja mocy biernej
farmy wiatrowe
linie kablowe
Opis:
The construction and installation of high-power wind farms triggers a number of problems related to the compensation of HV cable lines exporting power from a wind farm, and to the choice of compensation devices. The article describes problems that occur when wind farms are connected to the power system with a 110 kV line, characterizes the devices determining the reactive power balance. Two reactive power compensation systems FSR and STATCOM were also analyzed for minimizing the costs of compensation systems.
Źródło:
Advances in Science and Technology. Research Journal; 2020, 14, 4; 30-36
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania modelowe liczby Strouhala oblodzonego cięgna mostu podwieszonego
Model investigations of Strouhal number of iced cable of cable-stayed bridge
Autorzy:
Górski, P.
Pospišil, S
Kuznetsov, S
Tatara, M.
Marušić, A
Powiązania:
https://bibliotekanauki.pl/articles/391183.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
aerodynamika
oblodzenie
cięgno
liczba Strouhala
wzbudzenie wirowe
aerodynamic
icing
cable
Strouhal number
vortex shedding
Opis:
W artykule przedstawiono sposób i wyniki badań liczby Strouhala nieruchomego modelu oblodzonego cięgna mostu podwieszonego. Badania wykonano w tunelu aerodynamicznym z komorą klimatyczną Laboratorium Czeskiej Akademii Nauk w Telc. W komorze klimatycznej wykonano doświadczalne oblodzenie modelu cięgna o osi nachylonej pod kątem 300 do płaszczyzny poziomej. Kształt oblodzonej powierzchni zarejestrowano metodą fotogrametrii cyfrowej. Do badań w tunelu aerodynamicznym wykonano nowy model sekcyjny oblodzonego cięgna metodą druku 3D. Liczbę Strouhala wyznaczono w zakresie wartości liczby Reynoldsa od 28 do 122 na podstawie pomiaru częstości odrywania się wirów w śladzie aerodynamicznym za modelem.
The paper presents the method and results of wind tunnel investigations of Strouhal number of stationary iced cable model of cable-stayed bridge. The investigations were performed in a Climatic Wind Tunnel Laboratory of the Czech Academy of Sciences in Telc. The experimental icing of the inclined cable model in the climatic chamber of the laboratory was made. The shape of the iced model was registered by a numerical photogrammetry method. For the aerodynamic tunnel investigations, the new iced cable model was made by using 3D printing method. The Strouhal number was determined within the range of the Reynolds number between 28·103 and 122·103, on the basis of the dominant vortex shedding frequency measured in the flow behind the model.
Źródło:
Budownictwo i Architektura; 2014, 13, 2; 201-208
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Most Szanghaj Chongming na rzece Jangcy
Autorzy:
Dąbrowiecki, K.
Powiązania:
https://bibliotekanauki.pl/articles/364761.pdf
Data publikacji:
2011
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
Chiny
most
most podwieszony
Most Szanghaj Chongming
bridge
cable stayed bridge
China
Szanghaj Chongming bridge
Opis:
Delta rzeki Jangcy jest najbardziej rozwiniętą, uprzemysłowioną, dynamicznie rozwijającą się i jednocześnie jedną z najbardziej zaludnionych części Chin. Na obszarze ok. 110 tys. km2 zamieszkuje blisko 100 mln ludzi. To tak, jakby na terenie trzy razy mniejszym niż obszar Polski mieszkało dwa i pół razy więcej osób. W okresie ostatnich kilkudziesięciu lat fabryki i zakłady delty były i w dalszym ciągu są niekwestionowanym "złotym" źródłem krajowej gospodarki Chin, przynoszącym rocznie blisko 20% dochodu narodowego, absorbując przy tym prawie połowę wszystkich zagranicznych inwestycji.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2011, 2; 22-24
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kolej linowa przez Wisłę w Kazimierzu Dolnym
Aerial ropeway over the Vistula river in Kazimierz Dolny
Autorzy:
Rokita, T.
Powiązania:
https://bibliotekanauki.pl/articles/193617.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
koleje linowe
miejskie koleje linowe
promocja miasta
cable propelled transit
city ropeways
promotion of cities
Opis:
Wyniki prac nad projektem koncepcyjnym napowietrznej kolei linowej przez Wisłę w rejonie Kazimierza Dolnego. Uwarunkowania miejscowe budowy kolei linowej, proponowane rozwiązania techniczne i wybrane wyniki obliczeń. Problemy związane z ewakuacją pasażerów kolei prowadzonych nad akwenami wodnymi.
The results of works on the conceptual project of aerial ropeway over the Vistula river in Kazimierz Dolny region. Local conditions concerning ropeway construction, proposed technical solutions and selected results of calculations. Problems connected with passenger evacuation from aerial ropeways over the water areas.
Źródło:
Transport Miejski i Regionalny; 2010, 12; 38-42, 48
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cable-stayed cantilever structures as an expat of unique application in the construction of a building located in seismic area – an author’s project of multifunctional building in Lisbon, Portugal
Autorzy:
Grębowski, K.
Werdon, M.
Powiązania:
https://bibliotekanauki.pl/articles/265033.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
cantilever structures
seismic and dynamic analysis
cable-stayed structures
konstrukcja wspornikowa
konstrukcja budynku
trzęsienie ziemi
Opis:
The article presents numerical simulations for the modelling of seismic impact on the structure of unique cantilever cablestayed structure with the application of two methods. The Response Spectrum method, in which a spectrum of the structure’s responses to an earthquake’s impact is generated, and the Accelerogram method, in which we generate dynamic load in the form of a diagram of the connection between acceleration and time for the actual readings during a real earthquake. Both methods have been presented for the El Centro earthquake spectrum. This unique application of a cantilever cablestayed structure in public buildings will allow to assess the safety of this kind of load-bearing system in areas of increased risk of seismic activity. Cantilever cablestayed structures have so far never been designed or analyzed on seismically active areas. Based on numerical simulation we determined the effect of stiffness of load-bearing lines on the increase of stresses and displacements at cable stays joint with the end of the cantilever part of a building.
Źródło:
International Journal of Applied Mechanics and Engineering; 2015, 20, 4; 805-816
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspekty wdrożenia aparatury pomiarowej do lokalizacji uszkodzeń kabli i przewodów oponowych w urządzeniach zasilających w strefach zagrożonych wybuchem
Aspects of implementing the measuring apparatus to the location of damage to cables and rubber sheathed mining cables in the zones with the rish of the explosion in powering devices
Autorzy:
Kozłowski, A.
Kryca, M.
Mistarz, M.
Powiązania:
https://bibliotekanauki.pl/articles/186440.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
aparatura pomiarowa
uszkodzenia kabli
uszkodzenia przewodów
zagrożenie wybuchami
measuring apparatus
damage to cable lines
explosion hazards
Opis:
Artykuł opisuje problematykę zadania badawczego ukierunkowanego na opracowanie rozwiązań wraz z aparaturą pomiarową umożliwiającą przeprowadzenie pomiarów oraz diagnozowanie kabli i przewodów elektroenergetycznych w wyrobiskach zagrożonych wybuchem metanu i/lub pyłu węglowego. Przedstawiono sposób realizacji projektu przez konsorcjum naukowo-przemysłowe oraz opisano opracowane urządzenia RAKo i RAKn tworzące system nadawczo-odbiorczy, będące rezultatem projektu. Odniesiono się także do możliwości zabudowania aparatury w urządzeniu zasilającym odbiory w sieciach niskiego napięcia w układzie elektrycznym stacji transformatorowej typu MAR-G.
The article is describing issues of the research task directed at developing solutions, along with the measuring apparatus, enabling to take measurements and diagnose electrical power engineering cables and wires in the mine workings with the risk of explosion of methane and/or coal dust. The way of realisation of the project by the scientific-industrial consortium was presented as well as RAKo and RAKn devices, that were developed, were described, which are creating the transmit-ting-receiving system, being a result of the project. One has also referred to the possibility of developing apparatus in the device that is powering receptions in the low voltage webs, in the electric system of transformer station of the MAR-G type.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2014, R. 52, nr 4, 4; 3-13
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uproszczone modelowanie linii kablowych wysokiego napięcia a napięcia indukowane w żyłach powrotnych – studium przypadku
Simplified modeling of high voltage power cables vs. induced sheath voltages – case study
Autorzy:
Dobrzyński, Krzysztof
Czapp, Stanisław
Klucznik, Jacek
Lubośny, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/268389.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
modelowanie linii kablowych
napięcie indukowane
żyły powrotne
modeling of cable line
induced voltage
sheath-bonding systems
Opis:
Linie kablowe, obok linii napowietrznych, są jednym z podstawowych elementów składowych systemów elektroenergetycznych. Stosowane są głównie na terenach zurbanizowanych, gdzie prowadzenie linii napowietrznych jest mocno utrudnione lub wręcz niemożliwe. Linie kablowe wysokiego napięcia budowane są głównie z wykorzystaniem kabli, które oprócz żyły roboczej mają również współosiową żyłę powrotną. Istnieje kilka układów pracy takich linii, które różnią się sposobem uziemienia żył powrotnych i ewentualnym zastosowaniem przeplatania żył powrotnych i/lub żył roboczych. Budowa linii kablowej wysokiego napięcia każdorazowo powinna zostać poprzedzona analizą modelową, która pozwoli określić poziomy napięć i prądów indukowanych w żyłach powrotnych. Jak wynika z analiz, zbyt duże uproszczenia w modelowaniu mogą prowadzić do błędnego wnioskowania.
The construction of a high voltage cable lines should be preceded by a model analysis, which will allow to determine the levels of voltages and currents induced in their sheaths. In turn, the accuracy of modeling and the simplifications adopted in the model may lead to wrong conclusions.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 37-40
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Naziemne systemy transportu linowego wspomagające miejskie środki transportu – rozwiązania historyczne
Rope transport ground systems supporting urban public transport – historical solutions
Autorzy:
Magiera, T.
Wójcik, K.
Kułaga, P.
Powiązania:
https://bibliotekanauki.pl/articles/193538.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
tramwaj linowy
kolej linowo-terenowa
tramwaje konne
transport linowy
cable car
funicular
horse trams
rope transport
Opis:
W artykule przedstawiono historyczne, powstałe na przełomie XIX i XX wieku, rozwiązania techniczne różnych środków transportu miejskiego połączonych z naziemnymi systemami transportu linowego – tzw. połączeń hybrydowych. Opisano pierwsze połączenie systemów tramwajów linowych z wagonami kolejowymi, które funkcjonowało w Nowym Jorku jako środek transportu zapewniający przeprawę przez Most Brookliński.Przedstawiona została rozbudowa tego systemu, która zapewniła przepustowość przewozową na poziomie 30 milionów osób rocznie. Artykuł przedstawia również rozwiązania hybrydowe kolei linowo-terenowych służących do transportu tramwajów konnych i elektrycznych w Cincinnati oraz w Hoboken, USA. Były one szeroko stosowane w miejscach o dużych nachyleniach, których tramwaje nie były w stanie pokonać. Ponadto szczegółowo opisano istniejące rozwiązanie tramwaju elektrycznego we włoskim Trieście, którego trasa jest częściowo obsługiwana przez kolej linowo- terenową. Artykuł zawiera opis poszczególnych elementów tego systemu i udoskonalenia wprowadzane podczas całego okresu eksploatacji. Kolej linowo-terenowa, obsługująca najbardziej stromy odcinek trasy, została również opisana z uwzględnieniem zmieniających się rozwiązań technicznych pojazdów na przestrzeni prawie osiemdziesięcioletniej eksploatacji.
The article presents technical solutions of historical means of public transport connected with rope transport ground systems operated at the turn of the 19 century – so called „the hybrids”. Especially it shows a connection between elements of a cable car system with train carriages, which was installed and operated at the Brooklyn Bridge in New York up to the year 1908. Extension of this transportation system has enabled carrying up to 30 million passengers annually. Additionally, the purpose-built funiculars with platforms are presented in the article. They were adapted to carry horse and electric trams to ensure consistency of transport at local hills in Cincinnati and in Hoboken, USA. Moreover, the article presents characteristics of electric tram operating in Trieste, in Italy which has a track partly supported by a funicular system. The main elements of this transportation system and their development during the operation period are described. The funicular system, installed at the steepest part of the track, was described in terms of technical solutions for carriers during eighty years of the operation.
Źródło:
Transport Miejski i Regionalny; 2017, 1; 19-21
1732-5153
Pojawia się w:
Transport Miejski i Regionalny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical diagnostics of industrial double twist twinner machine for data cables
Autorzy:
Krenický, Tibor
Ružbarský, Juraj
Coranič, Tomáš
Maščeník, Jozef
Powiązania:
https://bibliotekanauki.pl/articles/2175488.pdf
Data publikacji:
2022
Wydawca:
STE GROUP
Tematy:
vibrodiagnostics
maintenance
twisted pair cables
return loss
cable fault
wibrodiagnostyka
konserwacja
kable typu skrętka
usterka kabla
Opis:
The presented article focuses on the diagnostic measurement and evaluation of vibrations of equipment used for data-cable twisted pairing manufacture. A short description of the process of the data cables manufacturing process to which the diagnosed device belongs is provided and the qualitative parameters of the data cables are mentioned. The experimental part is devoted to the experimental diagnostics of the given system in order to locate and identify the possible reason for the occurrence of the parameter´s critical value of the loss of the data cable. When deterioration of electric properties was detected, monitoring the basic oscillation characteristics has been deployed as the key tool to detecting damaged machine parts, and avoiding quality deterioration of the products in the manufacturing process. Finally, the quality of the paired cables after the repair has been confirmed by measurements verifying the efficiency of the measures performed.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2022, 11, 2; 35--46
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie wartości cieplnej stałej czasowej przewodów na podstawie pomiarów temperatury
Determine of thermal time - constant based on temperature measuring
Autorzy:
Lejdy, B.
Skibko, Z.
Powiązania:
https://bibliotekanauki.pl/articles/157234.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cieplna stała czasowa
przewód wielożyłowy
układ wielowarstwowy przewodów
thermal time
multiconductor cable
multilayer system of cables
Opis:
W artykule przedstawiono problematykę związaną z wyznaczaniem wartości cieplnej stałej czasowej przewodów elektrycznych ułożonych osobno oraz w układach wielowarstwowych. Przedstawiono ponadto analizę porównawczą wartości stałej T dostępnych w literaturze z wartościami wyznaczonymi w oparciu o przeprowadzone przez autorów badania laboratoryjne oraz omówiono sposób wyznaczania jej wartości na podstawie pomiarów temperatury w przewodzie w zależności od budowy przewodów oraz sposobu ich ułożenia.
The paper presents problems connected with determination of thermal time - constant value for single cable and for cables as multilayer system. The paper presents also comparative analysis of thermal time - constant T values which are in specialistic literature (these values are showed in the Table 1) with values of T determined on the base of laboratory temperature measurement. Determination of T value of cables depending on their structure and way of arranging is characterized. Fig. 1 has been presenting graphically the way of determination of thermal time constant T basing on conductor heating characteristic. Laboratory tests were carried out on laboratory stand, which diagram and view are showed in Fig. 2 and 3. Time values which are determined by authors on the temperature measurement base are showed in the Table 2. Table 3 presents values of thermal time - constant T depending on the way of arrangement (two or three layers) and number of conductors YDYżo 5 x 6 mm2.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 2, 2; 143-145
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagrożenie piorunowe linii kablowych wysokiego napięcia
Lighting hazard of high voltage power cable lines
Autorzy:
Boryń, H.
Powiązania:
https://bibliotekanauki.pl/articles/267641.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
zagrożenie przepięciowe
fale przepięciowe
linie kablowe
linie napowietrzne
overvoltage hazard
cable lines
overhead line
overvoltages waves
Opis:
Wskazano zasadnicze źródła zagrożenia piorunowego linii kablowych wysokiego napięcia eksploatowanych w systemach przesyłowym i dystrybucyjnym. Omówiono zjawiska falowe zachodzące w wyniku wyładowań atmosferycznych w różnych układach linii elektroenergetycznych i ich wpływ na wartości powstających przepięć. Przedstawiono rolę koordynacji izolacji w ochronie urządzeń wysokonapięciowych przed skutkami przepięć.
The work defines the main sources of overvoltage hazard of cable lines operated in the transmission system. We discussed the wave phenomena occurring at atmospheric discharges in different systems of power lines and their impact on the value of the overvoltages. The role of insulation coordination in protecting against overvoltages of HV devices have been presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 56; 11-18
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kompensacja linii kablowych 110 kV wyprowadzających moc z farm wiatrowych
Compensation of 110 kV cable lines connecting wind farms with the grid
Autorzy:
Kacejko, P.
Pijarski, P.
Adamek, S.
Powiązania:
https://bibliotekanauki.pl/articles/269192.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kompensacja mocy biernej
farmy wiatrowe
linie kablowe WN
reactive power compensation
HV cable lines
wind farms
Opis:
W referacie omówiono problemy kompensacji mocy biernej linii kablowych 110 kV o długościach kilkudziesięciu kilometrów. Linie takie są obecnie budowane głównie w celu przyłączenia farm wiatrowych, jako konsekwencja trudności w uzyskaniu pozwoleń na budowę linii napowietrznych. Praktyczne problemy projektowe wiążą się z faktem nieokreśloności pojemności kabla i reaktancji dławika (urządzenia niestandardowe produkowane jednostkowo) oraz zmiennością napięć w miejscu przyłączenia. Stosując podejście probabilistyczne zaproponowano możliwe rozwiązania w zakresie doboru urządzeń kompensacyjnych.
Application of 110 kV cable lines with length bigger than a few kilometers, is a standard engineering practice now. These cables are used mainly by wind farm developers for connecting them to power system in PCCs (Points of Common Coupling). Because of infrastructure limitations, it is impossible to built the new overhead lines, so cables occur to be one and only solution. As it is well known, HV cables are significant sources of the reactive power. It should be controlled and coordinated with general requirements of the grid operators. Application of a shunt reactor with fixed reactance (FSR), seems to be theoretically an easy task. On the other hand variability of power system parameters (voltage in PCC, active power in WF), constructional uncertainness of cable and reactor nominal parameters, forced us to look for more flexible solutions. As the alternative, the reactor with on load tap changer (OLTC) called Variable SR can be taken into account. In the paper two alternative methods of FSR versus VSR adjustment are considered.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 151-154
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of phase sequence selection on magnetic flux density curve of EHV cable line
Wpływ wyboru kolejności faz na krzywą gęstości strumienia magnetycznego w linii kablowej najwyższych napięć
Autorzy:
Belatka, M.
Paar, M.
Chodura, P.
Powiązania:
https://bibliotekanauki.pl/articles/407648.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
hygienic limits
cable line
magnetic field
phase sequence
limity środowiskowe
linia kablowa
pole magnetyczne
kolejność faz
Opis:
The article deals with the hygienic limits in the Czech Republic for electric and magnetic fields radiated by Extra High Voltage cables with focus on phase sequence selection for minimization of magnetic fields in the surroundings of cables and the change of magnetic flux density in the case of one cable set outage of EHV line.
Artykuł dotyczy limitów środowiskowych w Republice Czeskiej dla pól elektrycznych oraz magnetycznych w okolicach linii kablowych najwyższych napięć (NN), a zwłaszcza wyborem kolejności faz w celu minimalizacji pól magnetycznych w otoczeniu kabli oraz zmian gęstości strumienia magnetycznego w przypadku awarii jednej wiązki kabli.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2014, 3; 61-64
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology for Electric Cables Critical Infrastructure Network safety and resilience to climate change analysis
Autorzy:
Blokus-Roszkowska, A.
Kołowrocki, K.
Soszyńska-Budny, J.
Powiązania:
https://bibliotekanauki.pl/articles/2069016.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
energy sector
critical infrastructure network
electric cable critical infrastructure
extreme weather
climate change
resilience
energy security
Opis:
In the paper the energy sector as a critical infrastructure is presented and basic terminology concerned with the energy critical infrastructure is given. The interactions and connections between critical infrastructures are described and the effects of power disruptions to other critical infrastructures are highlighted. Next, presented terminology and taxonomy refer to climate change and resilience to climate change of electric cable critical infrastructure. Finally, taxonomy of electric cable critical infrastructure network in Baltic Sea Region is given, especially in terms of climate change and resilience to climate change. Basic notions related to extreme weather events and climate change having impact on energy generation, transmission and distribution are introduced.
Źródło:
Journal of Polish Safety and Reliability Association; 2016, 7, 2; 151--162
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies