Influence of the wastewater from chosen food processing industries on a quality of water in the mouth section of River Odra
Wpływ ścieków z wybranych zakładów przemysłu spożywczego na jakość wód powierzchniowych na terenie miasta Szczecina
Autorzy:
Wira, J.
Tarnowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/85105.pdf
Data publikacji:
2000
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
waste water
food processing industry
water quality
mouth section
Odra River
waste water treatment plant
Szczecin city
biological treatment
sewage treatment
biological sewage treatment
Opis:
Influence of the wastewater from chosen food processing industries located in Szczecin on a quality of receiver’s water was presented. The theoretical part of the paper comprises general fundamentals of the biological treatment of the wastewater, the sources of the wastewater and their impact onto a sewerage system and the receiver at meat processing and dairy industries were also presented in this part of the paper. Szczecin Dairy and Szczecin Poultry Processing Company are both equipped with biological wastewater treatment plants. The treated wastewater is discharged to the receivers that are directly linked to River Odra, thus has an impact on the quality of River Odra water. Basing on a performed research on parameters of untreated and treated wastewater, the treatment performance of the wastewater treatment plants was described as well as an attempt to estimation of an impact of the wastewater onto the receiver was made.
W pracy został przedstawiony wpływ wybranych zakładów przemysłu spożywczego zlokalizowanych w Szczecinie na jakość wody w odbiorniku. Teoretyczna część pracy opisuje generalne zasady biologicznego oczyszczania ścieków, źródła ścieków w omawianych zakładach - przetwórstwa mięsnego i mleczarni, a także wpływ tych ścieków na odbiornik. Ścieki ze Szczecińskich Zakładów Drobiarskich „DROBIMEX-HEINTZ” oraz Szczecińskich Zakładów Mleczarskich są oczyszczane w biologicznych oczyszczalniach ścieków. Oczyszczone ścieki są odprowadzane do odbiorników bezpośrednio połączonych z rzeka Odra, w związku z czym maja wpływ na jakość jej wód. W oparciu o przeprowadzone badania parametrów nie oczyszczonych i oczyszczonych ścieków dokonano oceny w/w zakładów na jakość wody w rzece Odrze w jej ujściowym odcinku.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2000, 04
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dairy wastewater treatment in anaerobic Dissimilation reduction of sulfates
Oczyszczanie ścieków mleczarskich w beztlenowej dysymilacyjnej redukcji siarczanów
Autorzy:
Wawrzak, D.
Kustal, W.
Powiązania:
https://bibliotekanauki.pl/articles/103704.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
sewage treatment
SRB
sulphur reducing bacteria
biological methods
Desulfotomaculum ruminis
oczyszczanie ścieków
BRS-bakterie redukujące siarkę
metody biologiczne
Opis:
The study ha as been devoted to testing the impact of sulfides to optimize the treatment of domestic waste, the proceeds of eco-tourism, anaerobic bacteria using desulfurization (specifically Desulfotomaculum ruminis). The most important and fundamental process, that has been discussed in this work is the treatment of wastewater. The main representatives of prokaryotes are bacteria of Desulfotomaculum ruminis genus. Bacteria induce sulfur-breathing process known as dissimilative sulfate reduction. Sulfate ions are the final acceptors of hydrogen and electrons. The end d product is a hydrogen sulfide. Its occurrence is evidence of a decrease in the concentration of organic substrates-decrease of COD.
Celem niniejszej pracy jest zbadanie możliwości zastosowania procesu oddychania siarkowego do usunięcia zanieczyszczeń organicznych w przypadku wycieku ścieków przemysłowych, jak również w oczyszczalniach ścieków. Prezentowane wyniki są kontynuacją programu badawczego dotyczącego wykorzystania różnych rodzajów bakterii w uzdatnianiu wody ścieków przemysłowych. Ogólnym celem tego badania było sprawdzenie możliwości wykorzystania BRS (bakterii redukujących siarczany), szczególnie Desulfotomaculum ruminis, w procesie oczyszczania ścieków przemysłu mleczarskiego. Ten rodzaj ścieków zawiera węglowodany, głównie laktozę (30,9% %), białka (23,6%, w tym 80% kazeiny) oraz tłuszcze (41,4%) pochodzące z mleka i jego przetworów. Przeprowadzone badania dotyczyły redukcji siarczanów w ściekach przemysłu mleczarskiego za pomocą szczepu bakterii Desulfotomaculum ruminis. Proces oddychania siarkowego prowadzono w warunkach laboratoryjnych za pomocą BRS po namnożeniu kultury bakteryjnej na podłożu Starkeya wzbogaconym ściekami mleczarskimi stanowiącymi jedyne źródła węgla i energii. Prowadzone badania oceniają wpływ bakterii na zmniejszenie zawartości siarki w zależności od stężenia ścieków. Badano zmiany ChZT, poziom zawartości siarczków, zmiany pH w badanych próbkach. Porównywane próbki zawierały 2%, 5%, 7.5% i 10% ścieków mleczarskich. Wyniki wykazały, że konieczne jest znalezienie optymalnego stosunku zawartości ścieków w zawiesinie poddanej działaniu BRS, jak również prowadzenie procesu w optymalnym czasie, w celu uzyskania maksymalnych wyników.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2014, T. 2; 405-412
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological decomposition of sulphates in industrial wastewater
Mikrobiologiczny rozkład siarczanów w ściekach przemysłowych
Autorzy:
Wawrzak, D.
Powiązania:
https://bibliotekanauki.pl/articles/103617.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
sulphur reducing bacteria
SRB
biological method
Desulfotomaculum ruminis
sewage treatment
dairy industry
bakterie redukujące siarczany
BRS
metoda biologiczna
oczyszczanie ścieków
przemysł mleczarski
Opis:
The study presents comparison of effectiveness in using microbial desulphurisation of dairy industry. Comparative study covers two factors describing performance and effectiveness depending on medium and wastewater content: COD and sulphites. Authoress proves that usage of SRB can be successfully exploited In significant reduction of sulphates and their immediate change into sulphides, which can be separated from the wastewater in form of sludge.
W pracy przedstawiono porównanie skuteczności w wykorzystaniu mikroorganizmów do odsiarczania ścieków przemysłu mleczarskiego. Analiza porównawcza obejmuje dwa czynniki opisujące działanie i skuteczność w zależności od medium i zawartości ścieków: ChZT i siarczany. Autorka dowodzi, że użycie BRS może być z powodzeniem wykorzystywane w znacznej redukcji siarczanów i ich natychmiastową zmianę do siarczków, które mogą być oddzielone od ścieków w postaci osadu.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2013, T. 1; 199-209
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological reduction of sulfates to sulphides used in dairy wastewater treatment
Mikrobiologiczna redukcja siarczanów do siarczynów w oczyszczalni ścieków w mleczarni
Autorzy:
Wawrzak, D.
Powiązania:
https://bibliotekanauki.pl/articles/318828.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
sulphur reducing bacteria
SRB
biological methods
Desulfotomaculum ruminis
sewage treatment
dairy industry
bakterie redukujące siarkę (SRB)
metody biologiczne
przeróbka osadów ściekowych
przemysł spożywczy
Opis:
The study presents comparison of effectiveness in using microbial desulphurication of dairy industry. Comparative study covers two factors describing performance and effectiveness depending on medium and wastewater content: COD and sulphites. Authoress proves that usage of SRB can be successfully exploited in significant reduction of sulphates and their immediate change into sulphites, which can be separated from the wastewater in form of sluge.
Badanie przedstawia porównanie efektywności w użyciu mikrobiologicznego odsiarczania w przemyśle mleczarskim. Badanie porównawcze obejmuje dwa aspekty opisujące wydajność i skuteczność w zależności od zawartości czynnika i ścieków: COD (chemical oxygen demand – chemiczne zapotrzebowanie tlenu) i siarczyny. Autor udowadnia, że użycie SRB może być pomyślnie wykorzystywane w znaczącej redukcji siarczanów i ich natychmiastową przemianę na siarczyny, które z kolei mogą być oddzielone od ścieków w formie szlamu.
Źródło:
Inżynieria Mineralna; 2013, R. 14, nr 2, 2; 109-114
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór parametrów konstrukcyjnych rotacyjnego złoża biologicznego metodą znacznikową
The Selection of Design Parameters of the Rotating Biological Contactor Using Tracer Studies
Autorzy:
Szulżyk-Cieplak, J.
Duda, A.
Lenik, K.
Powiązania:
https://bibliotekanauki.pl/articles/1818075.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
biologiczne złoże obrotowe
ścieki bytowe
biologiczne oczyszczanie ścieków
rotating biological contactor (RBC)
domestic sewage
biological wastewater treatment
Opis:
The subject of research consists in a rotational biological contactor with a rotor characterized by a bi-directional longitudinal flow as an element of synchronized system of disposal and biological treatment of sanitary wastewater in small-bore sewerage. The rotor design is based on a system of corrugated protective pipes, arranged in coils wound around its rotation axis. The corrugated pipes have two purposes. On the one hand, they ensure and enable the aeration of activated sludge, and provide the surface for biofilm development on the other. The special winding of corrugated pipes enables a bi-directional flow of the liquid medium. During the rotation of the rotor, the RBC is simultaneously emptied and filled with wastewater. The structure of the rotational biological contactor aims to provide intensive aeration of the transported wastewater, which would allow for a greater development of microorganisms participating in the hybrid treatment of wastewater, i.e. the activated sludge method and by means of a trickling filter. Design solutions of the rotor pertaining to coil arrangement and the drive system were analyzed and tracer studies of hydrodynamics were performed in regard to the selection of appropriate structural parameters of the device. The obtained results indicate a clear influence of the design solution and its kinematics on the aeration time of the flowing medium, which is one of the parameters governing the efficiency and quality of RBC operation.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 897-908
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Orzęski jako wskaźniki przebiegu oczyszczania ścieków na złożach zraszanych. Część I. Badania terenowe
Ciliata kak ukazatel processa ochishhenija stochnykh vod na orashaemykh zaleshakh
Ciliata as index of sewage decontamination on trickling filters. I. Field studies
Autorzy:
Stanislawska, J.
Powiązania:
https://bibliotekanauki.pl/articles/872715.pdf
Data publikacji:
1963
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
biologiczne oczyszczanie sciekow
scieki bytowe
zloza zraszane
orzeski
badania terenowe
biological sewage treatment
household sewage
water sprinkler
trickling filter
ciliate
field research
Źródło:
Roczniki Państwowego Zakładu Higieny; 1963, 14, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie frakcji CHZT w ściekach surowych dopływających do małych i dużych oczyszczalni ścieków
Comparison of the fractions of cod in raw wastewater influent for small and large sewage treatment
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/401888.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
frakcje ChZT
małe oczyszczalnie ścieków
złoża biologiczne
oczyszczalnia hydrofitowa
oczyszczalnia z osadem czynnym
COD fractions
small sewage treatment plants
rotary biological contactor
constructed wetland
treatment with activated sludge
Opis:
W artykule przedstawiono porównanie udziału frakcji ChZT w ściekach surowych w oczyszczalniach do których spływają małe ilości ścieków oraz oczyszczalnię z dużym przepływem. Porównano oczyszczalnię hydrofitową o średniej przepustowości 4 dm3/m, oczyszczalnię ze złożami biologicznymi o średniej przepustowości 8 dm3/m, oraz oczyszczalnię ścieków z osadem czynnym w Białymstoku o przepustowości około 70 000 m3/d. Najniższe udziały procentowe frakcji rozpuszczonych związków biologicznie nierozkładalnych SI w ściekach surowych odnotowano w małych oczyszczalniach ścieków. Na podstawie dostępnych danych niestwierdzono istotnych zależności między frakcjami XI, SS, XS w ściekach surowych a ilością wytwarzanych ścieków.
The article presents a comparison of the share fraction of COD in raw wastewater in treatment plants which flow in a small amount of wastewater and the sewage treatment with high flow. Compared the constructed wetlands with an average capacity of 4 dm3/m,, the treatment plant with biological deposits with an average capacity of 8 dm3/m, and a sewage treatment plant with activated sludge in Bialystok with a capacity of about 70 000 dm3/m. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was reported in raw sewage in small sewage treatment plants. Based on the available data wasn’t found significant correlation between the factions XI, SS, XS in raw sewage and the amount of wastewater.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 191-195
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frakcje ChZT ścieków w mechaniczno-biologicznej oczyszczalni
COD Fractions in mechanical-biological wastewater treatment plant
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Powiązania:
https://bibliotekanauki.pl/articles/1819509.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczalnie ścieków
oczyszczalnie mechaniczne
oczyszczalnie biologiczne
frakcje ChZT
sewage treatment plants
mechanical treatment
biological wastewater
COD fractions
Opis:
W pracy przeprowadzono ocenę skuteczności rozkładu zanieczyszczeń organicznych w ściekach po poszczególnych procesach mechaniczno-biologicznego oczyszczania ze szczególnym uwzględnieniem zmian frakcji ChZT w ciągu technologicznym oczyszczalni w Zielonej Górze.
In Polish literature there is little information regarding the distribution of COD fractions, therefore, identify the theoretical topic has been mainly based on foreign literature. Literature data 'tips a COD divided into factions as the most suitable for accurate characterization of organic matter in municipal wastewater. In Poland, continues for many years, to identify the organic matter in wastewater contractual indicators such as BOD5, CODCr, CODMn, organic carbon content and loss during roasting were used. Information on the composition of the effluent, obtained based on these conventional indicators, are much less accurate when compared with data obtained on the basis of COD fractions. In the majority of cases the values of concentration of biodegradable organic matter in wastewater is expressed in BOD5, whereas identification of COD fractions, additionally allows the evaluation of the amount of impurities which are non biodegradable and which decrease the efficiency of biological treatment. The paper presents results of studies concerning the designation of COD fraction in the raw wastewater and their alternations after subsequent processes in mechanical-biological wastewater treatment. The test object was a wastewater treatment plant for the city of Zielona Góra. Sampling of raw wastewater and wastewater after various stages of mechanical-biological treatment, and laboratory tests such as designating pollution indicators such as: CODMn, CODCr, BOD5, BODtot and TOC was performed according to Polish standards. During investigation following fractions of COD were also determined: dissolved non bioderadable SI, dissolved easily biodegradable SS, in organic suspension slowly degradable XS and in organic suspension non-biodegradable XI. Methodology for determining the COD fraction was based on the guidelines ATV A 131. Analysis of results of research concerning changes in fractions of COD in the wastewater treatment plant showed that: 1. More than 75% of the total COD in the raw wastewater inflowing to the wastewater treatment plant "Łącza" were biodegradable fractions: bound in suspension XS and dissolved SS, 2. Technological system of the mechanical-biological wastewater treatment plant in Zielona Góra does not change the solute concentration in the effluent of non-biodegradable dissolved fraction SI, 3. Changes in the percentage contribution of fraction XS, XI, and the SS were a consequence of biochemical changes occurring in the biological part of the plant, 4. CODCr indicator values in all analyzed wastewater samples were lower than the total COD, which is the sum of individual fractions of COD, 5. Differences between the effectiveness of work in the wastewater treatment plant in Zielona Góra based on CODCr and total COD were the order of 1%, 6. The values of the percentage contribution of XS, XI, SI, and SS fraction in the total COD of raw wastewater from Zielona Góra are consistent with the values given in the literature.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1157-1172
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of the sewer system rinsing on the wastewater composition
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Myszograj, S.
Suchowska-Kisielewicz, M.
Jakubaszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/207804.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sewers
pollution
sewage
sewage pumping plants
water treatment plants
biological reactor
sewage pollutions
wastewater treatment plants
kanalizacja
ścieki
przepompownie ścieków
stacje uzdatniania wody
reaktor biologiczny
zanieczyszczenia ścieków
oczyszczalnie ścieków
Opis:
The paper presents the results of research on the influence of the operational rinsing of a sewer system on the composition of raw sewage, the effectiveness of the operation of the mechanical part of a wastewater treatment plant and changes in the technological parameters of the biological reactor. The results of the research have shown an increase in sewage pollution during the rinsing of the sewer system. The value of the COD indicator increased from 799 to 1306 mg/dm3, BOD5 from 538 to 1044 mg/dm3, and total suspended solids from 259 to 1508 mg/dm3. The calculations indicate that an increase in the concentrations of pollution during the rinsing of the sewer system requires a high working efficiency of the mechanical part of the wastewater treatment plant. With a low efficiency the volume of the biological reactor can increase even by 30%.
Źródło:
Environment Protection Engineering; 2013, 39, 2; 5-13
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan awaryjny reaktorów biologicznych A i B znajdujących się na oczyszczalni ścieków w Wałczu jako skutek popełnionych błędów przy ich projekcie i użytkowaniu
Emergency state of biological reactors located in the area of sewage treatment plant in Walcz as a result of commited faults during their projection process and expliotation
Autorzy:
Przybyłowicz, E.
Pikos, M.
Powiązania:
https://bibliotekanauki.pl/articles/160299.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oczyszczalnia ścieków
zbiornik na ścieki
reaktor biologiczny
zbiornik żelbetowy
stan techniczny
pęknięcie
destrukcja betonu
analiza przyczyn
wastewater treatment plant
sewage tank
biological reactor
reinforced concrete tank
technical condition
crack
concrete destruction
causes analysis
Opis:
W pracy omówiono uszkodzenia i przyczyny, które doprowadziły do stanu awaryjnego dwóch reaktorów biologicznych na remontowanej oczyszczalni ścieków w Wałczu. Powstałe uszkodzenia ścian i den zbiorników stworzyły zagrożenie skażenia środowiska ściekami komunalnymi. Bezpośrednią przyczyną tego stanu były popełnione błędy na etapie projektowania konstrukcji zbiorników bez zachowania odpowiednich zasad odnośnie posadowienia, rozwiązań dylatacji, zbrojenia i wymagań co do jakości betonu. W reaktorach nie zastosowano odpowiednich powłok ochronnych na betonie, co w połączeniu ze złą jakością betonu doprowadziło do całkowitej degradacji obiektów i podjęcia decyzji o ich rozbiórce z uwagi na nieopłacalny remont.
Present paper discusses the damages and causes that led to the emergency condition of two biological reactors on the renovated sewage treatment plant in Walcz. Resulting damages of walls and bottom of tanks caused a risk of contamination of the environment with municipal sewage. The direct cause of this condition was mistakes/errors made at the stage of structural design of the tanks without maintaining proper rules of foundation process, construction of dilation, propositions of suitable reinforcements and concrete quality requirements. In the reactors appropriate protective coatings on a concrete were not used, which, in combination with poor quality of concrete, led to complete degradation of objects and decided to demolish them due to unprofitable repairs.
Źródło:
Przegląd Budowlany; 2017, 88, 9; 86-88
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of domestic sewage treatment system in the aspect of sustainable development
Analiza przydomowego systemu oczyszczania ścieków w aspekcie zrównoważonego rozwoju
Autorzy:
Pawlita-Posmyk, Monika
Wzorek, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/435080.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Opolski
Tematy:
domestic biological sewage treatment plants
cost analysis
sustainable development
przydomowe biologiczne oczyszczalnie ścieków
zrównoważony rozwój
analiza kosztów
Opis:
ear by year domestic sewage treatment plants are becoming more popular. A pilot solution used on a grand scale in Pietrowice Wielkie commune allowed for the construction of a sewage system for villages located far from each other and made the commune more attractive. This paper presents the analysis of investment and operating costs, the assessment of environmental benefits and social aspects. The solution used had a significant effect on the improvement of living conditions of the residents. The conducted analyses of the domestic sewage treatment system in the aspect of sustainable development allowed for the recognition of domestic biological sewage treatment plants as an economical, modern and safe solution and also as a cheap alternative to traditional sewerage systems.
Na terenach wiejskich, z roku na rok przydomowe oczyszczalnie ścieków mają coraz większe znaczenie. Zastosowanie tego systemu oczyszczania pozwala na rozwiązanie problemu ze ściekami zgodnie z zasadami zrównoważonego rozwoju. Przykładem terenu, na którym zamiast tradycyjnej kanalizacji zamontowano przydomowe biologiczne oczyszczalnie ścieków na dużą skalę, może być gmina Pietrowice Wielkie, która zlokalizowana jest w południowo – zachodniej części Polski. W gminie tej zastosowanie przydomowych biologicznych oczyszczalni ścieków pozwoliło na skanalizowanie oddalonych od siebie sołectw oraz zwiększenie atrakcyjności gminy. Nowoczesne bezpieczne dla środowiska rozwiązanie miało znaczący wpływ na polepszenie warunków życia mieszkańców przybliżając ich do europejskich standardów. Przedsięwzięcie zrealizowano dzięki pozyskanym środkom z pożyczki, dotacji, wkładzie własnym gminy i mieszkańców. W artykule dokonano analizy przydomowego systemu oczyszczania ścieków- funkcjonowania biologicznych przydomowych oczyszczalni ścieków w dużej skali w aspekcie zrównoważonego rozwoju. Dokonana analiza kosztów inwestycji i eksploatacji obiektów, aspektów środowiskowych oraz zadowolenia mieszkańców pozwoliła na stwierdzenie, że przydomowe biologiczne oczyszczalnie ścieków są ekonomicznym, nowoczesnym i bezpiecznym rozwiązaniem oraz tanią alternatywą w porównaniu z tradycyjnymi oczyszczalniami ścieków.
Źródło:
Economic and Environmental Studies; 2016, 16, 3(39); 491-500
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmian jakości ścieków w trakcie procesów oczyszczania na oczyszczalni w Przemyślu
The analysis of the changes in the sewage quality during treatment processes on the wastewater treatment plant in Przemyśl
Autorzy:
Młyńska, A.
Chmielowski, K.
Młyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/401056.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki
oczyszczanie mechaniczno-biologiczne
rozkład biologiczny
sewage
mechanical-biological treatment
biodegradability
Opis:
W oparciu o odnotowane wielkości BZT5, ChZTCr, azotu ogólnego (Nog.) i fosforu ogólnego (Pog.) w ściekach unieszkodliwianych w 2015 roku na oczyszczalni w Przemyślu dokonano oceny ich podatności na rozkład biologiczny. Przeprowadzona analiza wykazała, że skład ścieków surowych zapewniał właściwy przebieg i efektywność procesów biochemicznych, na co wskazują wyznaczone wartości ilorazów ChZTCr/BZT5, Nog./BZT5, Pog./BZT5. Ponadto, przeanalizowano zmiany wartości wskaźników zanieczyszczeń w ściekach po kolejnych etapach oczyszczania. W miarę postępującego procesu oczyszczania następowało stopniowe obniżanie ilości zanieczyszczeń organicznych i związków biogennych, których to największa redukcja osiągnięta została w wyniku procesów biologicznych. Wyniki te świadczą o prawidłowości przebiegu procesów zachodzących na pracującej w układzie dwustopniowym przemyskiej oczyszczalni.
On the basis of the noted BOD5, CODCr, total nitrogen (Ntot.) and total phosphorus (Ptot.) values in sewage treated in 2015 on the Wastewater Treatment in Przemyśl, the evaluation of the sewage biodegradability was performed. The conducted analysis showed that the composition of raw sewage provided proper biochemical processes and its effectiveness, which is evidenced by the calculated COD,sub>Cr/BOD5, Ntot./BOD5 and Ptot/BOD5 ratios. Moreover, the changes of pollutants indicators in the sewage after the next treatment stages were analyzed. As the sewage treatment process progressed, there was a gradual reduction of the organic and biogenic compounds. The largest reduction was achieved as a result of biological processes. The obtained results indicate the reliability of treatment processes in the two-stage system of Przemyśl wastewater treatment plant.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 5; 18-26
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ scieków miejskich i przemysłowych miasta Słupska na faunę denną rzeki Słupi
Vlijanie gorodskikh i promyshlennykh stokov goroda Slupska na donnuju faunu reki Slupi
The influence of sewage and industrial wastes of the city of Slupsk on the bottom fauna of the Slupia River
Autorzy:
Malej, J.
Powiązania:
https://bibliotekanauki.pl/articles/877003.pdf
Data publikacji:
1959
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
rzeka Slupia
scieki miejskie
scieki przemyslowe
Slupsk
wody rzeczne
fauna denna
badania fizykochemiczne
badania biologiczne
oczyszczanie sciekow
Slupia River
urban waste water
industrial sewage
Slupsk town
river water
bottom fauna
physicochemical research
biological investigation
sewage treatment
Źródło:
Roczniki Państwowego Zakładu Higieny; 1959, 10, 6
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wplyw parametrow technologicznych na ilosc biomasy w reaktorze biologicznym ze zlozem ruchomym
Influence of technological parameters on biomass in moving bed biological reactor
Autorzy:
Makowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/40139.pdf
Data publikacji:
2007
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
reaktory z ruchomymi zlozami biologicznymi
reaktory biologiczne
osady czynne
blony biologiczne
biomasa
parametry technologiczne
oczyszczanie sciekow
active deposit
bacterial jelly
biological reactor
biomass
sewage treatment
technological parameter
Źródło:
Acta Scientiarum Polonorum. Architectura; 2007, 06, 2; 59-70
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozpoznawanie niekorzystnych zjawisk mogących stwarzać ryzyko w komunalnej oczyszczalni ścieków
Recognition of unfavourable events that may pose a risk on municipal sewage treatment plant
Autorzy:
Łój-Pilch, M.
Zakrzewska, A.
Zielewicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/126534.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
identyfikacja ryzyka
urządzenia ciągów technologicznych
oczyszczanie mechaniczne
oczyszczanie biologiczne
oczyszczanie chemiczne
przeróbka osadów ściekowych
risk identification
technological process equipment
mechanical sewage treatment
biological sewage treatment
chemical sewage treatment
sewage sludge treatment
Opis:
Oczyszczalnie ścieków są obiektami technicznymi, których zadaniem jest usunięcie substancji stałych i rozpuszczonych, koloidów oraz zawiesin ze ścieków przed odprowadzeniem ich do odbiornika. Wykorzystuje się w tym celu procesy mechaniczne, biologiczne i chemiczne. W części mechanicznej stosuje się te same podstawowe procesy separacji i sedymentacji, służące do odseparowania cząstek mineralnych i łatwoopadalnych cząstek organicznych, natomiast na technologię części biologicznej i chemicznej mają wpływ (zgodnie z obowiązującym aktualnie rozporządzeniem MŚ) przede wszystkim równoważna ilość mieszkańców (RLM) oraz rodzaj odbiornika. Komunalne oczyszczalnie ścieków można ogólnie podzielić na takie, w których nie zachodzi konieczność usuwania związków biogennych (mogą bazować na technologii złóż biologicznych), oraz takie, w których usuwane są związki azotu i fosforu, bazujące głównie na osadzie czynnym. Dodatkowo, w zależności od jakości ścieków i wymagań odbiornika można stosować doczyszczanie chemiczne. Różnorodność procesów i konstrukcji występujących na oczyszczalni ścieków generuje powstawanie zjawisk stwarzających ryzyko dla podstawowego celu oczyszczalni. Zidentyfikowanie tych zjawisk w poszczególnych elementach ciągów technologicznych stanowi podstawę procesu zarządzania ryzykiem obiektu technicznego.
Wastewater treatment plants are technical facilities designed to remove solids and dissolved solids, colloids and suspensions from wastewater before drainage them to the receiver. For this purpose, mechanical, biological and chemical processes are used. The mechanical section consists of the basic processes used to separate mineral solids and easily settleable organic solids, however the technology of the biological and chemical sections depends on (according to the current Regulation Minister of the Environment) Equivalent number of inhabitants and type of outfall. Municipal sewage treatment plants can generally be divided for those that do not need to remove biogenic compounds (they can be based on the technology of biological filters) and those in which nitrogen and phosphorus compounds are removed, mainly based on activated sludge. Moreover, depending on the quality of the waste water and the requirements of the receiver, chemical sewage treatment can be used. Variety of applied processes and construction at wastewater treatment plants causes the occurrence of unfavourable events that pose a risk to the primary purpose of a treatment plant. Identifying those events is the basis for the risk management process in a technical facility.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 195-201
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies