Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "biological sewage treatment" wg kryterium: Temat


Wyświetlanie 1-33 z 33
Tytuł:
Chemico-biological sewage treatment plants for PE< 9.999
Chemiczno-biologiczne oczyszczalnie ścieków dla RLM < 9 999
Autorzy:
Heidrich, Z.
Stańko, G.
Powiązania:
https://bibliotekanauki.pl/articles/396506.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
ścieki
oczyszczanie ścieków
oczyszczalnia chemiczno-biologiczna
sewage
chemico-biological sewage treatment plants
nitrogen and phosphorus compounds
Opis:
Removal of nitrogen and phosphorus compounds is not required in the case of sewage treatment plants serving the settlement units of up to 9.999 citizens and not charging treated sewage into staying waters. Therefore, it is possible to reduce the range of water treatment to merely two requirements: the BOD_5 and the concentration of suspended solids. It gives a possibility to use another technological solution in such sewage treatment plants. As a result, due to chemical pre-treatment, size of biological reactors can be substantially reduced. Such approach is justified not only by technical, but predominantly by economical issues.
W oczyszczalniach ścieków obsługujących jednostki osadnicze zasiedlone przez nie więcej niż 10 000 mieszkańców i nie odprowadzających ścieków oczyszczonych do wód stojących, nie jest wymagane usuwanie związków azotu i fosforu. Istnieje zatem możliwość ograniczenia zakresu oczyszczania ścieków do dwóch wymagań: obniżenia BZT_5 i stężenia zawiesin ogólnych. Daje to możliwość zastosowania innego rozwiązania technologicznego w takich oczyszczalniach ścieków. W takim rozwiązaniu w bardzo istotnym stopniu wykorzystuje się wstępne chemiczne oczyszczanie, które ogranicza w znacznym stopniu wielkość reaktorów biologicznych. Takie podejście ma uzasadnienie nie tylko techniczne ale przede wszystkim ekonomiczne.
Źródło:
Civil and Environmental Engineering Reports; 2007, 2; 27-35
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ czynników fizyko-chemicznych na specjację fosforu w osadach ściekowych powstających w technologii EvU-Perl
The effect of selected physical and chemical factors on speciation of phosphorus in sewage sludge produced with application of the Evu-Perl technology
Autorzy:
Bezak-Mazur, E.
Mazur, A.
Powiązania:
https://bibliotekanauki.pl/articles/1819812.pdf
Data publikacji:
2009
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
Evu-Perl technology
specjacja fosforu
osady ściekowe
biologiczne oczyszczalnie
phosphorus speciation
biological sewage treatment
Opis:
W osadach ściekowych powstających po oczyszczeniu ścieków komunalnych znajdują się związki fosforu i azotu. Tak więc osady ściekowe można traktować jako wtórne źródło biogenów [14]. Jedną z istotnych informacji pozwalających ocenić rolę osadów jako wtórnego źródła biogenów jest ilość zawartego w nich fosforu biologicznie dostępnego, który może być uwalniany z osadów i wykorzystywany w procesie produkcji pierwotnej. Do określenia zawartości fosforu biologicznie dostępnego wykorzystuje się metody analizy specjacyjnej. W naszych wcześniejszych badaniach wybrano metody analizy specjacyjnej fosforu w osadach [2], a następnie zbadanie jego specjacji w osadach powstających przy oczyszczaniu ścieków z wykorzystaniem różnych rozwiązań technologicznych i różnych warunków prowadzenia procesu oczyszczania. Dotychczas zbadano specjację fosforu w osadzie nadmiernym powstającym podczas oczyszczania ścieków metodą osadu czynnego [3, 4] i poddawanym działaniu różnych warunków fizyko-chemicznych. W niniejszej pracy zaprezentowano wyniki badań specjacji fosforu w osadzie powstającym w technologii EvU-Perl, stanowiącej swoiste połączenie metody osadu czynnego z zawirowalnym złożem biologicznym. Technologia EvU-Perl jest przykładem zastosowania immobilizacji biomasy w oczyszczaniu ścieków. Biomasa jest unieruchamiana na walcowatych kształtkach wykonanych z materiału polimerycznego. Kształtki stanowią wypełnienie komór napowietrzania.
Amounts of phosphorus liberated from sewage sludge during biological wastewater treatment depend on chemical, biological and physical conditions which are found in a treatment plant. Presence of oxygen is one of the basic conditions which decides of phosphorus liberation and accumulation. Under anaerobic conditions liberation of phosphorus through so-called return dissolving takes place [8], while under aerobic conditions phosphorus is assimilated by bacteria present in the sludge mass or in the biological film. Phosphorus speciation in sewage sludge obtained with the EvU-Perl technology was analyzed using the Golterman method. The investigation was conducted for sludge samples subjected to the action of such factors as oxygenation, ultrasonification, precipitation and temperature changes in reference to unprepared sludge. The results show that the predominant fraction of phosphorus, with the content being more than 40%, is Ca-EDTA-P with phosphorus in the biologically available form. Oxygenation is reported to have the greatest influence on P speciation. For a sludge from biological deposit EvU-Perl substantially lower differences of part of phosphorus speciation fractions in comparison to examined earlier [3, 4] sewage sludge coming from wastewater treatment plant using activated sludge method. Lower influence of physico-chemical factors on speciation is caused by movement of shapes used in the deposit, which weaken impact of factors. Even so, in order to determine dependence between part of phosphorus speciation forms in sewage sludge and impact of phisico-chemical factors, analysis of multiple regression was conducted. Values of coefficients achieved after analysis are given in table 2. To sum up data in table 2 following conclusions may be formulated: oxygenation has the biggest impact on speciation of phosphorus in sewage sludge coming from biological deposit EvU-Perl, influence of other examined parameters is lower, part of mobile and biologically available fractions is increasing during oxygenation; this creates favourable conditions of phosphorus availability when sewage sludge is used in agriculture.
Źródło:
Rocznik Ochrona Środowiska; 2009, Tom 11; 381-391
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the wastewater from chosen food processing industries on a quality of water in the mouth section of River Odra
Wpływ ścieków z wybranych zakładów przemysłu spożywczego na jakość wód powierzchniowych na terenie miasta Szczecina
Autorzy:
Wira, J.
Tarnowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/85105.pdf
Data publikacji:
2000
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
waste water
food processing industry
water quality
mouth section
Odra River
waste water treatment plant
Szczecin city
biological treatment
sewage treatment
biological sewage treatment
Opis:
Influence of the wastewater from chosen food processing industries located in Szczecin on a quality of receiver’s water was presented. The theoretical part of the paper comprises general fundamentals of the biological treatment of the wastewater, the sources of the wastewater and their impact onto a sewerage system and the receiver at meat processing and dairy industries were also presented in this part of the paper. Szczecin Dairy and Szczecin Poultry Processing Company are both equipped with biological wastewater treatment plants. The treated wastewater is discharged to the receivers that are directly linked to River Odra, thus has an impact on the quality of River Odra water. Basing on a performed research on parameters of untreated and treated wastewater, the treatment performance of the wastewater treatment plants was described as well as an attempt to estimation of an impact of the wastewater onto the receiver was made.
W pracy został przedstawiony wpływ wybranych zakładów przemysłu spożywczego zlokalizowanych w Szczecinie na jakość wody w odbiorniku. Teoretyczna część pracy opisuje generalne zasady biologicznego oczyszczania ścieków, źródła ścieków w omawianych zakładach - przetwórstwa mięsnego i mleczarni, a także wpływ tych ścieków na odbiornik. Ścieki ze Szczecińskich Zakładów Drobiarskich „DROBIMEX-HEINTZ” oraz Szczecińskich Zakładów Mleczarskich są oczyszczane w biologicznych oczyszczalniach ścieków. Oczyszczone ścieki są odprowadzane do odbiorników bezpośrednio połączonych z rzeka Odra, w związku z czym maja wpływ na jakość jej wód. W oparciu o przeprowadzone badania parametrów nie oczyszczonych i oczyszczonych ścieków dokonano oceny w/w zakładów na jakość wody w rzece Odrze w jej ujściowym odcinku.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2000, 04
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of domestic sewage treatment system in the aspect of sustainable development
Analiza przydomowego systemu oczyszczania ścieków w aspekcie zrównoważonego rozwoju
Autorzy:
Pawlita-Posmyk, Monika
Wzorek, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/435080.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Opolski
Tematy:
domestic biological sewage treatment plants
cost analysis
sustainable development
przydomowe biologiczne oczyszczalnie ścieków
zrównoważony rozwój
analiza kosztów
Opis:
ear by year domestic sewage treatment plants are becoming more popular. A pilot solution used on a grand scale in Pietrowice Wielkie commune allowed for the construction of a sewage system for villages located far from each other and made the commune more attractive. This paper presents the analysis of investment and operating costs, the assessment of environmental benefits and social aspects. The solution used had a significant effect on the improvement of living conditions of the residents. The conducted analyses of the domestic sewage treatment system in the aspect of sustainable development allowed for the recognition of domestic biological sewage treatment plants as an economical, modern and safe solution and also as a cheap alternative to traditional sewerage systems.
Na terenach wiejskich, z roku na rok przydomowe oczyszczalnie ścieków mają coraz większe znaczenie. Zastosowanie tego systemu oczyszczania pozwala na rozwiązanie problemu ze ściekami zgodnie z zasadami zrównoważonego rozwoju. Przykładem terenu, na którym zamiast tradycyjnej kanalizacji zamontowano przydomowe biologiczne oczyszczalnie ścieków na dużą skalę, może być gmina Pietrowice Wielkie, która zlokalizowana jest w południowo – zachodniej części Polski. W gminie tej zastosowanie przydomowych biologicznych oczyszczalni ścieków pozwoliło na skanalizowanie oddalonych od siebie sołectw oraz zwiększenie atrakcyjności gminy. Nowoczesne bezpieczne dla środowiska rozwiązanie miało znaczący wpływ na polepszenie warunków życia mieszkańców przybliżając ich do europejskich standardów. Przedsięwzięcie zrealizowano dzięki pozyskanym środkom z pożyczki, dotacji, wkładzie własnym gminy i mieszkańców. W artykule dokonano analizy przydomowego systemu oczyszczania ścieków- funkcjonowania biologicznych przydomowych oczyszczalni ścieków w dużej skali w aspekcie zrównoważonego rozwoju. Dokonana analiza kosztów inwestycji i eksploatacji obiektów, aspektów środowiskowych oraz zadowolenia mieszkańców pozwoliła na stwierdzenie, że przydomowe biologiczne oczyszczalnie ścieków są ekonomicznym, nowoczesnym i bezpiecznym rozwiązaniem oraz tanią alternatywą w porównaniu z tradycyjnymi oczyszczalniami ścieków.
Źródło:
Economic and Environmental Studies; 2016, 16, 3(39); 491-500
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodical aspects of bioreactor modeling in wastewater management
Aspekty metodyczne modelowania bioreaktorów gospodarki ściekowej
Autorzy:
Łagód, G.
Suchorab, Z.
Sobczuk, H.
Malicki, J.
Montusiewicz, A.
Widomski, M.
Powiązania:
https://bibliotekanauki.pl/articles/126426.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mathematical modeling of bioreactor
wastewater treatment plant
biological sewage treatment
activated sewage sludge
modelowanie matematyczne bioreaktorów
oczyszczalnie ścieków
biologiczne oczyszczanie ścieków
osad czynny
Opis:
Mathematical models are generally created for the needs of the processes control and for the simulations of processes occurring at the really existing objects. For the control of the bioreactors, even for multiparameter models, it is popular to apply both calibration and application at the linear ranges of interactions. If the bioreactor runs the process based on the defined substrate with the application of the previously defined processing factor (for strains, not only species) as an effect only the determined product and the excess biomass are obtained. Also, if the process undergoes in the optimal, constant physical-chemical-biotical conditions, its mathematical description can contain the elements of not only description of transition function but also of mechanisms responsible for the process realization. A kind of bioreactor like a n-step municipal sewage treatment plant with the activated sewage sludge has the unidentified, multicomponent substrate, which differs both in the daily and weekly scale with the multispecies and variable composition. Also, such a bioreactor works in the wide extend of physical-chemical conditions and time-dependent inhibiting factors. Only the product - purified wastewater - is defined by standards and should have the appropriate parameters. It is clear that models with elements describing the process mechanisms have to be complicated and multifactor, thus, the nonlinear models are capable to describe not only the local and global maxima and minima, but also the extreme situations. The models sufficient for processes control and operation should only describe the transition function in the linear interaction of the process important factors (independent variables). That explains the background of the aim of the paper as a methodical assumption presentation of models describing bioreactors like sewage treatment plants with activated sludge together with the elements of the processes running in the particular facilities and calibration of such a model by biomonitoring.
Modele matematyczne mogą być wykorzystywane na potrzeby sterowania procesami w obiektach eksploatowanych, a także do symulacji procesów poza realnie istniejącymi obiektami. Dla sterowania obiektami, takimi jak bioreaktory, praktykowane jest - nawet dla modeli wieloczynnikowych - zarówno ich kalibrowanie, jak i stosowanie w przedziałach oddziaływań liniowych. Jeżeli bioreaktor realizuje proces zdefiniowanego substratu z użyciem zdefiniowanego czynnika procesowego (zdefiniowanego dla szczepu, a nie tylko gatunku) w efekcie uzyskiwany jest ściśle określony produkt i nadmiarowa biomasa czynnika. Ponadto, jeśli proces realizowany jest w optymalnych, ustalonych warunkach fizyczno-chemiczno-biotycznych, matematyczny model procesu może zawierać w sobie elementy opisujące nie tylko funkcje przejścia, lecz również mechanizmy odpowiadające za przebieg procesu. Bioreaktor taki jak n-stopniowa oczyszczalnia ścieków miejskich z osadem czynnym ma niezidentyfikowany, wieloskładnikowy substrat, który jest zmienny w czasie zarówno w skali dobowej, tygodniowej, jak również rocznej. Niezdefiniowany jest również czynnik procesowy o składzie wielogatunkowym i wielorodzajowym, a często nawet wielotypowym. Ponadto bioreaktor taki pracuje w szerokim zakresie warunków fizycznych, chemicznych (różnorodne i różnie przyswajalne źródła C, N, P) oraz różnorodnych i zmiennych w czasie czynników inhibitujących. Jedynie produkt - oczyszczone ścieki - jest ustawowo definiowany i musi spełniać parametry określone w pozwoleniu wodno-prawnym. Jest zatem oczywiste, że modele zawierająceelementy opisujące mechanizmy procesu muszą być rozbudowane i wieloczynnikowe (ponadto nieliniowe), jeśli mają opisywać lokalne oraz globalne maksima i minima, a także sytuacje ekstremalne. Modele przydatne dla sterowania procesami zachodzącymi w urządzeniach oczyszczalni mogą opisywać funkcje przejścia jedynie w liniowych oddziaływaniach ważnych procesowo czynników (zmiennych niezależnych). Celem opracowania jest przedstawienie zasad tworzenia modeli opisujących bioreaktor typu „oczyszczalnia z osadem czynnym” zarówno z wykorzystaniem procesów realizowanych w poszczególnych obiektach, jak i przedstawiających jedynie funkcje przejścia.
Źródło:
Proceedings of ECOpole; 2010, 4, 1; 67-72
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozpoznawanie niekorzystnych zjawisk mogących stwarzać ryzyko w komunalnej oczyszczalni ścieków
Recognition of unfavourable events that may pose a risk on municipal sewage treatment plant
Autorzy:
Łój-Pilch, M.
Zakrzewska, A.
Zielewicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/126534.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
identyfikacja ryzyka
urządzenia ciągów technologicznych
oczyszczanie mechaniczne
oczyszczanie biologiczne
oczyszczanie chemiczne
przeróbka osadów ściekowych
risk identification
technological process equipment
mechanical sewage treatment
biological sewage treatment
chemical sewage treatment
sewage sludge treatment
Opis:
Oczyszczalnie ścieków są obiektami technicznymi, których zadaniem jest usunięcie substancji stałych i rozpuszczonych, koloidów oraz zawiesin ze ścieków przed odprowadzeniem ich do odbiornika. Wykorzystuje się w tym celu procesy mechaniczne, biologiczne i chemiczne. W części mechanicznej stosuje się te same podstawowe procesy separacji i sedymentacji, służące do odseparowania cząstek mineralnych i łatwoopadalnych cząstek organicznych, natomiast na technologię części biologicznej i chemicznej mają wpływ (zgodnie z obowiązującym aktualnie rozporządzeniem MŚ) przede wszystkim równoważna ilość mieszkańców (RLM) oraz rodzaj odbiornika. Komunalne oczyszczalnie ścieków można ogólnie podzielić na takie, w których nie zachodzi konieczność usuwania związków biogennych (mogą bazować na technologii złóż biologicznych), oraz takie, w których usuwane są związki azotu i fosforu, bazujące głównie na osadzie czynnym. Dodatkowo, w zależności od jakości ścieków i wymagań odbiornika można stosować doczyszczanie chemiczne. Różnorodność procesów i konstrukcji występujących na oczyszczalni ścieków generuje powstawanie zjawisk stwarzających ryzyko dla podstawowego celu oczyszczalni. Zidentyfikowanie tych zjawisk w poszczególnych elementach ciągów technologicznych stanowi podstawę procesu zarządzania ryzykiem obiektu technicznego.
Wastewater treatment plants are technical facilities designed to remove solids and dissolved solids, colloids and suspensions from wastewater before drainage them to the receiver. For this purpose, mechanical, biological and chemical processes are used. The mechanical section consists of the basic processes used to separate mineral solids and easily settleable organic solids, however the technology of the biological and chemical sections depends on (according to the current Regulation Minister of the Environment) Equivalent number of inhabitants and type of outfall. Municipal sewage treatment plants can generally be divided for those that do not need to remove biogenic compounds (they can be based on the technology of biological filters) and those in which nitrogen and phosphorus compounds are removed, mainly based on activated sludge. Moreover, depending on the quality of the waste water and the requirements of the receiver, chemical sewage treatment can be used. Variety of applied processes and construction at wastewater treatment plants causes the occurrence of unfavourable events that pose a risk to the primary purpose of a treatment plant. Identifying those events is the basis for the risk management process in a technical facility.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 195-201
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Orzęski jako wskaźniki przebiegu oczyszczania ścieków na złożach zraszanych. Część I. Badania terenowe
Ciliata kak ukazatel processa ochishhenija stochnykh vod na orashaemykh zaleshakh
Ciliata as index of sewage decontamination on trickling filters. I. Field studies
Autorzy:
Stanislawska, J.
Powiązania:
https://bibliotekanauki.pl/articles/872715.pdf
Data publikacji:
1963
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
biologiczne oczyszczanie sciekow
scieki bytowe
zloza zraszane
orzeski
badania terenowe
biological sewage treatment
household sewage
water sprinkler
trickling filter
ciliate
field research
Źródło:
Roczniki Państwowego Zakładu Higieny; 1963, 14, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skutecznosc oczyszczania sciekow w systemach hydrofitowych na przykladzie zloz trzcinowych z przeplywem poziomym
The efficiency of wastewater treatment in horizontal subsurface flow constructed wetlands
Autorzy:
Karczmarczyk, A
Mosiej, J.
Powiązania:
https://bibliotekanauki.pl/articles/40453.pdf
Data publikacji:
2007
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
oczyszczalnie hydrofitowe
przeplyw poziomy
biologiczne oczyszczanie sciekow
zloza gruntowo-roslinne
materialy filtracyjne
efektywnosc oczyszczania
scieki bytowe
hydrophyte treatment plant
horizontal flow
biological sewage treatment
soil-plant deposit
filtration material
sewage treatment efficiency
household sewage
Źródło:
Acta Scientiarum Polonorum. Architectura; 2007, 06, 4; 79-87
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Suitability of sewage from the production of organic polymers for biological treatment
Autorzy:
Frąk, M.
Zadura, A.
Powiązania:
https://bibliotekanauki.pl/articles/101185.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
industrial sewage
biological treatment
biodegradability
activated sludge
Opis:
The possibility of biological treatment of sewage from the production of organic polymers was assessed. The chemical quality of raw and treated sewage (CODCr, BOD5 , ammonia nitrogen, nitrate nitrogen, total suspension, pH, chlorides and sulfates) was analyzed. The level of reduction in the analysed sewage quality indicators (%), sewage biodegradability (α) and the technical efficiency of treatment (Psw) were determined. It was shown that the limited effectiveness of the treatment process results from the excessively high load of organic contaminants. The analysed sewage contains substances which do not biodegrade easily, negatively influencing the conditions for activated sludge processes in the bioreactor. The activated sludge is characterized by low biodiversity and has an insufficient structure. The treatment process requires an introduction of technological changes which will lead to a decrease in the load of sewage entering the bioreactor.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/3; 1593-1602
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of extraneous waters on the proportion of sewage pollution indices regarding its biological treatment
Autorzy:
Kaczor, G.
Bergel, T.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/59684.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
extraneous water
proportion
sewage
pollution index
biological treatment
denitrification
dephosphatation
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2015, IV/3
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza skuteczności działania oczyszczalni ścieków pracującej w systemie SBR
Performance analysis of sewage treatment plant working in the SBR system
Autorzy:
Bartkowska, I.
Klaus, W.
Powiązania:
https://bibliotekanauki.pl/articles/908416.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
gospodarka ściekowa
projektowanie oczyszczalni
oczyszczalnia ścieków
skuteczność oczyszczania ścieków
sewage treatment
biological sequencing batch reactor
designing sewage treatment plant
sewage treatment plant
effluent treatment effect
Opis:
Technologia oczyszczania ścieków osadem czynnym w systemach porcjowych znana już była na początku XX wieku. W 1912 roku Fowler zastosował do oczyszczania ścieków miejskich w Manchesterze napowietrzanie ścieków strumieniem pęcherzyków powietrza wytwarzanych w sposób pneumatyczny wraz z następującym po nim etapem sedymentacji. W 1914 roku studenci Fowle'a – Ardern i Lockett – zaprezentowali oczyszczanie ścieków w systemie z napełnianiem i dekantacją bez pozbywania się biologicznych osadów nagromadzonych w czasie cyklicznego napowietrzania ścieków.
This paper presents an assessment of wastewater treatment plants operating in the technological sequence of biological reactors (SBR) as an example Olecko. This paper presents qualitative characteristics of raw sewage to the treatment plant infl uent and effl uent. Assesses the work of the treatment on the basis of tests erformed and operating experience. The analysis is based on the results of the following indicators of pollutants: OD5, COD, pH, concentration of total nitrogen, total phosphorus and total suspended solids. A description of modernized in 2009 technology of sewage treatment plant and sewage sludge management was presented.
Źródło:
Ekonomia i Środowisko; 2013, 4; 107-117
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmian jakości ścieków w trakcie procesów oczyszczania na oczyszczalni w Przemyślu
The analysis of the changes in the sewage quality during treatment processes on the wastewater treatment plant in Przemyśl
Autorzy:
Młyńska, A.
Chmielowski, K.
Młyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/401056.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki
oczyszczanie mechaniczno-biologiczne
rozkład biologiczny
sewage
mechanical-biological treatment
biodegradability
Opis:
W oparciu o odnotowane wielkości BZT5, ChZTCr, azotu ogólnego (Nog.) i fosforu ogólnego (Pog.) w ściekach unieszkodliwianych w 2015 roku na oczyszczalni w Przemyślu dokonano oceny ich podatności na rozkład biologiczny. Przeprowadzona analiza wykazała, że skład ścieków surowych zapewniał właściwy przebieg i efektywność procesów biochemicznych, na co wskazują wyznaczone wartości ilorazów ChZTCr/BZT5, Nog./BZT5, Pog./BZT5. Ponadto, przeanalizowano zmiany wartości wskaźników zanieczyszczeń w ściekach po kolejnych etapach oczyszczania. W miarę postępującego procesu oczyszczania następowało stopniowe obniżanie ilości zanieczyszczeń organicznych i związków biogennych, których to największa redukcja osiągnięta została w wyniku procesów biologicznych. Wyniki te świadczą o prawidłowości przebiegu procesów zachodzących na pracującej w układzie dwustopniowym przemyskiej oczyszczalni.
On the basis of the noted BOD5, CODCr, total nitrogen (Ntot.) and total phosphorus (Ptot.) values in sewage treated in 2015 on the Wastewater Treatment in Przemyśl, the evaluation of the sewage biodegradability was performed. The conducted analysis showed that the composition of raw sewage provided proper biochemical processes and its effectiveness, which is evidenced by the calculated COD,sub>Cr/BOD5, Ntot./BOD5 and Ptot/BOD5 ratios. Moreover, the changes of pollutants indicators in the sewage after the next treatment stages were analyzed. As the sewage treatment process progressed, there was a gradual reduction of the organic and biogenic compounds. The largest reduction was achieved as a result of biological processes. The obtained results indicate the reliability of treatment processes in the two-stage system of Przemyśl wastewater treatment plant.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 5; 18-26
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
"Sitkówka" w fazie prób generalnych
Autorzy:
Gładyszowska-Dawid, M.
Powiązania:
https://bibliotekanauki.pl/articles/363968.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
ochrona środowiska
oczyszczalnia ścieków
oczyszczalnia ścieków Sitówka
reaktor biologiczny
biological reactor
environment protection
sewage treatment plant
sewage treatment plant Sitówka
Opis:
Nowy reaktor biologiczny w Oczyszczalni Ścieków .Sitkówka. rozmiarami dorównuje boisku piłkarskiemu, a każdy z czterech zbudowanych tu osadników wtórnych wielkością i kształtem przypomina mały stadion. Zarówno skala obiektów, jak i stopień skomplikowania technologicznego pokazują, jak wiele wysiłku wymaga oczyszczanie ścieków i ich przywrócenie obiegowi wody w przyrodzie. Patrząc na uruchomiony właśnie w ramach projektu Funduszu Spójności Rozbudowa i modernizacja Oczyszczalni Ścieków .Sitkówka. dla miasta Kielce pierwszy ciąg technologiczny oczyszczalni, widać gołym okiem, że warto...
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 5; 48-50
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of heavy precipitation on the infiltration and inflow into small sewage treatment plants in 2010
Autorzy:
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/60233.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
heavy rainfall
infiltration
inflow
small sewage treatment plant
sewage treatment plant
sewer system
weather
treatment plant
Malopolska voivodship
Krakow city
mechanical treatment plant
biological treatment plant
modernization
Opis:
The aim of the study was to determine the extent to which heavy rainfall, that occurred in 2010, affected the infiltration into the selected sewage treatment plants in the Małopolskie voivodeship. The research was conducted in four separate sewer systems, located in poviats adjacent to the city of Kraków, discharging sewage to mechanical-biological treatment plants with a capacity below 1000 m3•d-1. The amount of sewage and extraneous water in the average wet year (2008) were used as control. As a result of heavy precipitation in 2010 the sewer system A received 18 539 m3 more extraneous water than in 2008 (increase by 343%), the sewer sys-tem B - 22 822 m3 (increase by 163%), the sewer system C - 109 715 m3 (increase by 248%) and the sewer system D - 30 796 m3 (increase by 303%). Heavy precipitation in 2010 caused the increase of infiltration and inflow by 264% on average in all studied sewer systems compared to the average wet year. As the result of precipitation, whose annual total in 2010 was higher by 65% than the normal value in 2008, there was an increase in the annual share of extraneous water from 5.3 to 19.7% depending on the facility. The volume of extraneous water, which was discharged into the studied treatment plants in 2010 (the period of heavy rainfall), constituted the following share of the annual value: in the sewer system A - 41.3%, in the sewer system B - 21.2%, in the sewer system C - 14.4%, in the sewer system D - 22.9%. Assuming the average gross amount of 3 PLN paid for treatment of 1 m3 of sewage, cost of extraneous water disposal in 2010 amounted from 78 533 PLN to 552 165 PLN, depending on the facility. The results obtained in the present study suggest that eliminating or reducing infiltration and inflow into the analyzed sewer systems would allow for large financial savings associated with reducing costs both for their transport and treatment as well as for modernization of facilities to enhance their hydraulic eapacity.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 12
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and technological analysis of individual wastewater treatment systems
Techniczna i technologiczna analiza indywidualnych mechaniczno-biologicznych oczyszczalni ścieków
Autorzy:
Jakubaszek, A.
Stadnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/396532.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wastewater treatment systems
individual sewage treatment systems
biological technologies
mechanical and biological treatment plants
systemy oczyszczania ścieków
indywidualne oczyszczalnie ścieków
technologia biologiczna
oczyszczalnia mechaniczno-biologiczna
Opis:
The article characterises most frequently selected by investors individual mechanical and biological sewage treatment systems. On the basis of gathered information and technical documentation, technical and technological analysis of the devices was conducted. Assessfactors include technology, structure, workflow, control, exploitation conditions, and sewage treatment system effectiveness. On the basis of conducted analysis, limited possibility of using activated sludge wastewater treatment in a flow system was established due to the difficulty of stabilizing the whole system. An optimal solution for individual wastewater treatment system are solutions of activated sludge technology in SBR system and hybrid technologies.
W artykule scharakteryzowano najczęściej wybierane przez inwestorów indywidualne mechaniczno-biologiczne oczyszczalnie ścieków. Na podstawie zebranych informacji oraz dokumentacji techniczno-ruchowej przeprowadzono analizę techniczno-technologiczną urządzeń. Oceniano przyjętą technologię, budowę, system pracy, zastosowane sterowanie oraz warunki eksploatacji i efektywną pracę oczyszczalni. Na podstawie przeprowadzonej analizy ustalono ograniczone możliwości stosowania oczyszczalni działających w technologii osadu czynnego w układzie przepływowym z uwagi na trudność w utrzymaniu stabilnej pracy całego systemu. Optymalnym rozwiązaniem oczyszczania ścieków pochodzących z indywidualnych gospodarstw są rozwiązania pracujące w technologii osadu czynnego w systemie SBR oraz technologie hybrydowe.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(1); 87-99
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór parametrów konstrukcyjnych rotacyjnego złoża biologicznego metodą znacznikową
The Selection of Design Parameters of the Rotating Biological Contactor Using Tracer Studies
Autorzy:
Szulżyk-Cieplak, J.
Duda, A.
Lenik, K.
Powiązania:
https://bibliotekanauki.pl/articles/1818075.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
biologiczne złoże obrotowe
ścieki bytowe
biologiczne oczyszczanie ścieków
rotating biological contactor (RBC)
domestic sewage
biological wastewater treatment
Opis:
The subject of research consists in a rotational biological contactor with a rotor characterized by a bi-directional longitudinal flow as an element of synchronized system of disposal and biological treatment of sanitary wastewater in small-bore sewerage. The rotor design is based on a system of corrugated protective pipes, arranged in coils wound around its rotation axis. The corrugated pipes have two purposes. On the one hand, they ensure and enable the aeration of activated sludge, and provide the surface for biofilm development on the other. The special winding of corrugated pipes enables a bi-directional flow of the liquid medium. During the rotation of the rotor, the RBC is simultaneously emptied and filled with wastewater. The structure of the rotational biological contactor aims to provide intensive aeration of the transported wastewater, which would allow for a greater development of microorganisms participating in the hybrid treatment of wastewater, i.e. the activated sludge method and by means of a trickling filter. Design solutions of the rotor pertaining to coil arrangement and the drive system were analyzed and tracer studies of hydrodynamics were performed in regard to the selection of appropriate structural parameters of the device. The obtained results indicate a clear influence of the design solution and its kinematics on the aeration time of the flowing medium, which is one of the parameters governing the efficiency and quality of RBC operation.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 897-908
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of carbon source and nitrate concentration on denitrification of high-nitrate wastewater
Autorzy:
Horová, Dorota
Bezucha, Petr
Růžičková, Iveta
Powiązania:
https://bibliotekanauki.pl/articles/207338.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
activated sludge
biological denitrification
sewage treatment plant
osad czynny
oczyszczalnia ścieków
denitryfikacja biologiczna
Opis:
The aim of the present work was to study the applicability of the activated sludge from a municipal wastewater treatment plant for high strength nitrate denitrification process. A sequenced batch reactor operated at initial nitrate concentration in the range from 750 to 8500 mg NO3 -N/dm3 .The effectiveness of various carbon sources on denitrification rate and nitrite accumulation was studied. The average specific denitrification rate was in the range from 58 to 62 mg NO3 -N /(g VSS·h) for ethanol, glycerol, molasses and whey. The denitrification with methanol was not effective.
Źródło:
Environment Protection Engineering; 2020, 46, 1; 73-89
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frakcje ChZT ścieków w mechaniczno-biologicznej oczyszczalni
COD Fractions in mechanical-biological wastewater treatment plant
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Powiązania:
https://bibliotekanauki.pl/articles/1819509.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczalnie ścieków
oczyszczalnie mechaniczne
oczyszczalnie biologiczne
frakcje ChZT
sewage treatment plants
mechanical treatment
biological wastewater
COD fractions
Opis:
W pracy przeprowadzono ocenę skuteczności rozkładu zanieczyszczeń organicznych w ściekach po poszczególnych procesach mechaniczno-biologicznego oczyszczania ze szczególnym uwzględnieniem zmian frakcji ChZT w ciągu technologicznym oczyszczalni w Zielonej Górze.
In Polish literature there is little information regarding the distribution of COD fractions, therefore, identify the theoretical topic has been mainly based on foreign literature. Literature data 'tips a COD divided into factions as the most suitable for accurate characterization of organic matter in municipal wastewater. In Poland, continues for many years, to identify the organic matter in wastewater contractual indicators such as BOD5, CODCr, CODMn, organic carbon content and loss during roasting were used. Information on the composition of the effluent, obtained based on these conventional indicators, are much less accurate when compared with data obtained on the basis of COD fractions. In the majority of cases the values of concentration of biodegradable organic matter in wastewater is expressed in BOD5, whereas identification of COD fractions, additionally allows the evaluation of the amount of impurities which are non biodegradable and which decrease the efficiency of biological treatment. The paper presents results of studies concerning the designation of COD fraction in the raw wastewater and their alternations after subsequent processes in mechanical-biological wastewater treatment. The test object was a wastewater treatment plant for the city of Zielona Góra. Sampling of raw wastewater and wastewater after various stages of mechanical-biological treatment, and laboratory tests such as designating pollution indicators such as: CODMn, CODCr, BOD5, BODtot and TOC was performed according to Polish standards. During investigation following fractions of COD were also determined: dissolved non bioderadable SI, dissolved easily biodegradable SS, in organic suspension slowly degradable XS and in organic suspension non-biodegradable XI. Methodology for determining the COD fraction was based on the guidelines ATV A 131. Analysis of results of research concerning changes in fractions of COD in the wastewater treatment plant showed that: 1. More than 75% of the total COD in the raw wastewater inflowing to the wastewater treatment plant "Łącza" were biodegradable fractions: bound in suspension XS and dissolved SS, 2. Technological system of the mechanical-biological wastewater treatment plant in Zielona Góra does not change the solute concentration in the effluent of non-biodegradable dissolved fraction SI, 3. Changes in the percentage contribution of fraction XS, XI, and the SS were a consequence of biochemical changes occurring in the biological part of the plant, 4. CODCr indicator values in all analyzed wastewater samples were lower than the total COD, which is the sum of individual fractions of COD, 5. Differences between the effectiveness of work in the wastewater treatment plant in Zielona Góra based on CODCr and total COD were the order of 1%, 6. The values of the percentage contribution of XS, XI, SI, and SS fraction in the total COD of raw wastewater from Zielona Góra are consistent with the values given in the literature.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1157-1172
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of the sewer system rinsing on the wastewater composition
Autorzy:
Sadecka, Z.
Płuciennik-Koropczuk, E.
Myszograj, S.
Suchowska-Kisielewicz, M.
Jakubaszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/207804.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sewers
pollution
sewage
sewage pumping plants
water treatment plants
biological reactor
sewage pollutions
wastewater treatment plants
kanalizacja
ścieki
przepompownie ścieków
stacje uzdatniania wody
reaktor biologiczny
zanieczyszczenia ścieków
oczyszczalnie ścieków
Opis:
The paper presents the results of research on the influence of the operational rinsing of a sewer system on the composition of raw sewage, the effectiveness of the operation of the mechanical part of a wastewater treatment plant and changes in the technological parameters of the biological reactor. The results of the research have shown an increase in sewage pollution during the rinsing of the sewer system. The value of the COD indicator increased from 799 to 1306 mg/dm3, BOD5 from 538 to 1044 mg/dm3, and total suspended solids from 259 to 1508 mg/dm3. The calculations indicate that an increase in the concentrations of pollution during the rinsing of the sewer system requires a high working efficiency of the mechanical part of the wastewater treatment plant. With a low efficiency the volume of the biological reactor can increase even by 30%.
Źródło:
Environment Protection Engineering; 2013, 39, 2; 5-13
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warbud buduje "Czajkę"
Autorzy:
Ambroża-Urbanek, B.
Powiązania:
https://bibliotekanauki.pl/articles/364196.pdf
Data publikacji:
2010
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
ekologia
inwestycje
oczyszczalnia ścieków Czajka
reaktor biologiczny
Warszawa
biological reactor
ecology
investment
Sewage-Treatment Plant Czajka
Warsaw
Opis:
Po latach protestów i przymiarek ruszyła wreszcie inwestycja rozbudowy i modernizacji Oczyszczalni Ścieków "Czajka". Ta największa inwestycja ekologiczna Warszawy, ma niebagatelne znaczenie nie tylko dla środowiska. Obok budowy Mostu Północnego i metra to inwestycja kluczowa dla funkcjonowania stolicy.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2010, 3; 22-25
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i modernizacja oczyszczalni Kujawy w Krakowie
Construction and modernization of Kujawy water treatment plant in Kraków
Autorzy:
Biedrzycka, A.
Powiązania:
https://bibliotekanauki.pl/articles/364223.pdf
Data publikacji:
2013
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
oczyszczalnia ścieków
modernizacja
gospodarka wodno-ściekowa
reaktor biologiczny
wastewater treatment plant
modernization
water-sewage management
biological reactor
Opis:
Wodociągi Krakowskie rozbudowują oczyszczalnię ścieków Kujawy. Powstała w Nowej Hucie w latach 90. XX w., początkowo przede wszystkim z myślą o utylizacji ścieków fenolowych z kombinatu metalurgicznego, przyjmuje dziś ścieki bytowe nie tylko z terenu dzielnicy. Oczyszczalnia zostanie zmodernizowana, gdyż nie spełnia już unijnych wymagań ekologicznych. Inwestycja, określana jako budowa i modernizacja oczyszczalni Kujawy, musi zostać ukończona szybko z uwagi na konieczność dostosowania jakości ścieków do wymogów dyrektywy 91/271/EWG (tzw. dyrektywy ściekowej) do końca 2015 r.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2013, 6; 38-41
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of post-sewage waters on relations between exchangeable cations in soils
Autorzy:
Dechnik, I
Filipek, T.
Powiązania:
https://bibliotekanauki.pl/articles/1449943.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
post-sewage water
relationship
soil
municipal waste
cation
biogenic component
soil property
eroded soil
degraded ecosystem
mechanical-biological treatment plant
anthropogenic ecosystem
sewage
Opis:
Research was carried out on the basis of investigations from the years 1996-1998 on the so-called monoliths in the soils derived from loess formations. Properties of those formations were differentiated by landscape and processes of water erosion. It was found out that post-sewage waters (waters received after sewage treatment) from a mechanical-biological sewage treatment plant have a more favourable influence on both the value of acidification indexes and relations between cations in the soils than solid mineral salts.
Źródło:
Acta Agrophysica; 2001, 51; 29-35
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dairy wastewater treatment in anaerobic Dissimilation reduction of sulfates
Oczyszczanie ścieków mleczarskich w beztlenowej dysymilacyjnej redukcji siarczanów
Autorzy:
Wawrzak, D.
Kustal, W.
Powiązania:
https://bibliotekanauki.pl/articles/103704.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
sewage treatment
SRB
sulphur reducing bacteria
biological methods
Desulfotomaculum ruminis
oczyszczanie ścieków
BRS-bakterie redukujące siarkę
metody biologiczne
Opis:
The study ha as been devoted to testing the impact of sulfides to optimize the treatment of domestic waste, the proceeds of eco-tourism, anaerobic bacteria using desulfurization (specifically Desulfotomaculum ruminis). The most important and fundamental process, that has been discussed in this work is the treatment of wastewater. The main representatives of prokaryotes are bacteria of Desulfotomaculum ruminis genus. Bacteria induce sulfur-breathing process known as dissimilative sulfate reduction. Sulfate ions are the final acceptors of hydrogen and electrons. The end d product is a hydrogen sulfide. Its occurrence is evidence of a decrease in the concentration of organic substrates-decrease of COD.
Celem niniejszej pracy jest zbadanie możliwości zastosowania procesu oddychania siarkowego do usunięcia zanieczyszczeń organicznych w przypadku wycieku ścieków przemysłowych, jak również w oczyszczalniach ścieków. Prezentowane wyniki są kontynuacją programu badawczego dotyczącego wykorzystania różnych rodzajów bakterii w uzdatnianiu wody ścieków przemysłowych. Ogólnym celem tego badania było sprawdzenie możliwości wykorzystania BRS (bakterii redukujących siarczany), szczególnie Desulfotomaculum ruminis, w procesie oczyszczania ścieków przemysłu mleczarskiego. Ten rodzaj ścieków zawiera węglowodany, głównie laktozę (30,9% %), białka (23,6%, w tym 80% kazeiny) oraz tłuszcze (41,4%) pochodzące z mleka i jego przetworów. Przeprowadzone badania dotyczyły redukcji siarczanów w ściekach przemysłu mleczarskiego za pomocą szczepu bakterii Desulfotomaculum ruminis. Proces oddychania siarkowego prowadzono w warunkach laboratoryjnych za pomocą BRS po namnożeniu kultury bakteryjnej na podłożu Starkeya wzbogaconym ściekami mleczarskimi stanowiącymi jedyne źródła węgla i energii. Prowadzone badania oceniają wpływ bakterii na zmniejszenie zawartości siarki w zależności od stężenia ścieków. Badano zmiany ChZT, poziom zawartości siarczków, zmiany pH w badanych próbkach. Porównywane próbki zawierały 2%, 5%, 7.5% i 10% ścieków mleczarskich. Wyniki wykazały, że konieczne jest znalezienie optymalnego stosunku zawartości ścieków w zawiesinie poddanej działaniu BRS, jak również prowadzenie procesu w optymalnym czasie, w celu uzyskania maksymalnych wyników.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2014, T. 2; 405-412
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie symulacji komputerowej procesu osadu czynnego do minimalizowania potencjału eutrofizującego ścieków oczyszczonych
Computer simulation of activated sludge process to obtain the minimum eutrophication potential of municipal wastewater
Autorzy:
Kowalewski, Z.
Neverova-Dziopak, E.
Preisner, M.
Powiązania:
https://bibliotekanauki.pl/articles/236334.pdf
Data publikacji:
2016
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie ścieków
reaktor biologiczny
substancje biogenne
potencjał eutrofizujący
modelowanie komputerowe
BioWin
sewage treatment
biological reactor
nutrients
eutrophication potential
computer modeling
Opis:
Po 15 latach wdrażania Ramowej Dyrektywy Wodnej, której podstawowym celem było osiągniecie w 2015 r. dobrego stanu wszystkich wód w państwach unijnych, okazało się, że tylko 53% wód powierzchniowych w Europie osiągnęło ten cel, a nadmiar substancji biogennych występuje w około 30% wód w 17 państwach członkowskich, w tym także w Polsce. Taki stan powoduje dalszy rozwój eutrofizacji i związane z tym poważne komplikacje w zakresie wszystkich kategorii użytkowania wód. Fakty te wskazują na niekorzystny bilans poniesionych kosztów i uzyskanych korzyści w zakresie zapobiegania negatywnym skutkom eutrofizacji poprzez ograniczanie wprowadzania do wód powierzchniowych substancji biogennych z oczyszczalni ścieków, a także na brak osiągnięcia założonych efektów ekologicznych przy ogromnych nakładach inwestycyjnych i eksploatacyjnych. Oznacza to, że nadal występują luki w zakresie ustalania warunków wprowadzenia ścieków do wód, które nie uwzględniają wiedzy na temat postaci substancji biogennych potęgujących proces eutrofizacji. W środowisku wodnym takimi formami biogenów są ich formy bioprzyswajalne (mineralne), bezpośrednio dostępne dla autotroficznych organizmów roślinnych. Wyniki przeprowadzonych badań symulacyjnych, nakierowanych na poszukiwanie prostszych i tańszych technologii biologicznego usuwania substancji biogennych i odprowadzanie do odbiornika ścieków oczyszczonych o niskim potencjale eutrofizującym, potwierdziły możliwość doboru skutecznych technologii usuwania substancji biogennych, które jednocześnie pozwolą na ograniczenie kosztów inwestycyjnych i eksploatacyjnych oczyszczania ścieków i bardziej skuteczną ochronę odbiorników przed eutrofizacją.
15 years from starting the implementation of Water Framework Directive, primary objective of which was to achieve good status of all waters in the EU countries by 2015, only 53% of surface waters in Europe have reached the set goal, and excessive amounts of nutrients are observed in about 30% of water bodies in 17 member states, including Poland. Consequently, the eutrophication progresses causing serious complications with regard to all the water use categories. These facts indicate an unfavorable cost-benefit balance in terms of preventing adverse effects of eutrophication by reducing nutrient discharge from wastewater treatment plants and failure to achieve the set ecological goals despite huge capital expenditures and operating costs. This means that gaps in respect of determining the conditions of wastewater discharge into the receivers still exist, which prevent taking into account the knowledge on nutrient forms accelerating eutrophication. In the aquatic environment such forms of nutrients are their bioavailable mineral forms, immediately assimilable by autotrophic plant organisms. The results of computer simulations, aimed at identification of simpler and cheaper technologies of biological nutrient removal and discharge of an effluent of low eutrophication potential, confirmed feasibility of selecting effective nutrient removal technologies that would also limit the investment and operational costs of sludge wastewater treatment and provide more effective protection of receivers against eutrophication.
Źródło:
Ochrona Środowiska; 2016, 38, 3; 23-28
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological decomposition of sulphates in industrial wastewater
Mikrobiologiczny rozkład siarczanów w ściekach przemysłowych
Autorzy:
Wawrzak, D.
Powiązania:
https://bibliotekanauki.pl/articles/103617.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
sulphur reducing bacteria
SRB
biological method
Desulfotomaculum ruminis
sewage treatment
dairy industry
bakterie redukujące siarczany
BRS
metoda biologiczna
oczyszczanie ścieków
przemysł mleczarski
Opis:
The study presents comparison of effectiveness in using microbial desulphurisation of dairy industry. Comparative study covers two factors describing performance and effectiveness depending on medium and wastewater content: COD and sulphites. Authoress proves that usage of SRB can be successfully exploited In significant reduction of sulphates and their immediate change into sulphides, which can be separated from the wastewater in form of sludge.
W pracy przedstawiono porównanie skuteczności w wykorzystaniu mikroorganizmów do odsiarczania ścieków przemysłu mleczarskiego. Analiza porównawcza obejmuje dwa czynniki opisujące działanie i skuteczność w zależności od medium i zawartości ścieków: ChZT i siarczany. Autorka dowodzi, że użycie BRS może być z powodzeniem wykorzystywane w znacznej redukcji siarczanów i ich natychmiastową zmianę do siarczków, które mogą być oddzielone od ścieków w postaci osadu.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2013, T. 1; 199-209
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis of the horizontal sub-surface flow constructed wetland under different hydraulic loading rates for rural domestic wastewater treatment
Autorzy:
Khairalla, A. M. O.
Xiwu, L.
Ladu, J. L.
Wenbo, Z.
Powiązania:
https://bibliotekanauki.pl/articles/207342.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
HFCW
Horizontal Flow Constructed Wetlands
rural sewage treatment plants
biological processes
retention time
oczyszczalnia hydrofitowa
wiejskie oczyszczalnie ścieków
czas retencji
procesy biologiczne
Opis:
The performance of horizontal subsurface flow constructed wetland (HFCW) for rural domestic sewage treatment has been evaluated. The system was built as a tertiary treatment after the biological processes to improve the effluent wastewater quality. The HFCW was operated in three phases under different hydraulic loading rates (HLRs), and with three kinds of aquatic plants i.e., water spinach, Chinese celery and cress. The vegetation growth parameters such as plant height, fresh and dry weights were monitored and analyzed. The influent and effluent concentrations of the chemical oxygen demand (COD), ammonium nitrogen (NH4+-N), total nitrogen (TN) and total phosphorus (TP) were measured. The average removal efficiencies at the first phase were 52.9%, 64.7%, 58.2% and 72.8%, and it reduced to 48.6%, 52.2%, 44.04% and 64.4% in the second phase for COD, NH4+-N, TN and TP, respectively. In the third phase, the HFCW system showed the following mean removal efficiencies: 51.2%, 74.2%, 58.5% and 80.9%. The results revealed that the removal efficiencies increased with decrease in the HLR and increased temperatures. The findings confirmed that the horizontal flow constructed wet-land is more convenient for the rural wastewater treatment with efficient nutrient removal.
Źródło:
Environment Protection Engineering; 2016, 42, 4; 107-121
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie frakcji CHZT w ściekach surowych dopływających do małych i dużych oczyszczalni ścieków
Comparison of the fractions of cod in raw wastewater influent for small and large sewage treatment
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/401888.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
frakcje ChZT
małe oczyszczalnie ścieków
złoża biologiczne
oczyszczalnia hydrofitowa
oczyszczalnia z osadem czynnym
COD fractions
small sewage treatment plants
rotary biological contactor
constructed wetland
treatment with activated sludge
Opis:
W artykule przedstawiono porównanie udziału frakcji ChZT w ściekach surowych w oczyszczalniach do których spływają małe ilości ścieków oraz oczyszczalnię z dużym przepływem. Porównano oczyszczalnię hydrofitową o średniej przepustowości 4 dm3/m, oczyszczalnię ze złożami biologicznymi o średniej przepustowości 8 dm3/m, oraz oczyszczalnię ścieków z osadem czynnym w Białymstoku o przepustowości około 70 000 m3/d. Najniższe udziały procentowe frakcji rozpuszczonych związków biologicznie nierozkładalnych SI w ściekach surowych odnotowano w małych oczyszczalniach ścieków. Na podstawie dostępnych danych niestwierdzono istotnych zależności między frakcjami XI, SS, XS w ściekach surowych a ilością wytwarzanych ścieków.
The article presents a comparison of the share fraction of COD in raw wastewater in treatment plants which flow in a small amount of wastewater and the sewage treatment with high flow. Compared the constructed wetlands with an average capacity of 4 dm3/m,, the treatment plant with biological deposits with an average capacity of 8 dm3/m, and a sewage treatment plant with activated sludge in Bialystok with a capacity of about 70 000 dm3/m. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was reported in raw sewage in small sewage treatment plants. Based on the available data wasn’t found significant correlation between the factions XI, SS, XS in raw sewage and the amount of wastewater.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 191-195
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological reduction of sulfates to sulphides used in dairy wastewater treatment
Mikrobiologiczna redukcja siarczanów do siarczynów w oczyszczalni ścieków w mleczarni
Autorzy:
Wawrzak, D.
Powiązania:
https://bibliotekanauki.pl/articles/318828.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
sulphur reducing bacteria
SRB
biological methods
Desulfotomaculum ruminis
sewage treatment
dairy industry
bakterie redukujące siarkę (SRB)
metody biologiczne
przeróbka osadów ściekowych
przemysł spożywczy
Opis:
The study presents comparison of effectiveness in using microbial desulphurication of dairy industry. Comparative study covers two factors describing performance and effectiveness depending on medium and wastewater content: COD and sulphites. Authoress proves that usage of SRB can be successfully exploited in significant reduction of sulphates and their immediate change into sulphites, which can be separated from the wastewater in form of sluge.
Badanie przedstawia porównanie efektywności w użyciu mikrobiologicznego odsiarczania w przemyśle mleczarskim. Badanie porównawcze obejmuje dwa aspekty opisujące wydajność i skuteczność w zależności od zawartości czynnika i ścieków: COD (chemical oxygen demand – chemiczne zapotrzebowanie tlenu) i siarczyny. Autor udowadnia, że użycie SRB może być pomyślnie wykorzystywane w znaczącej redukcji siarczanów i ich natychmiastową przemianę na siarczyny, które z kolei mogą być oddzielone od ścieków w formie szlamu.
Źródło:
Inżynieria Mineralna; 2013, R. 14, nr 2, 2; 109-114
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena przydatności osadów ściekowych w nawożeniu roślin
The assessment of the usefulness of sewage sludge in plant fertilisation
Autorzy:
Jakubus, M.
Powiązania:
https://bibliotekanauki.pl/articles/337970.pdf
Data publikacji:
2006
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
gorczyca
łubin
nawożenie
osad ściekowy z mechanicznej i mechniczno-biologicznej oczyszczalni ścieków
fertilisation
lupine
mustard
sewage sludges from mechanical and mechanical-biological treatment plants
Opis:
W doświadczeniu wazonowym badano wpływ osadów ściekowych na plon i skład chemiczny roślin. Osady pochodzące z mechanicznej oraz mechaniczno-biologicznej oczyszczalni ścieków dawkowano do gleby, biorąc pod uwagę ilość azotu dostarczaną do wazonu. Wynosiła ona 2 g. Doświadczenie założono na glebie lekkiej, a roślinami testowymi były gorczyca biała (Sinapis alba L.) odmiany Nakielska oraz łubin biały (Lupinus albus L.) odmiany Bardo. Rośliny do badań pobrano w fazie pełnej dojrzałości. Na podstawie uzyskanych wyników stwierdzono, że w zależności od metody oczyszczania, osady dodane do gleby odmiennie kształtowały plony oraz skład roślin. Nawożenie osadem z oczyszczalni mechaniczno-biologicznej zwiększyło plon gorczycy, natomiast nawożenie osadem z oczyszczalni mechanicznej zwiększyło plon łubinu. Nawożenie osadami ściekowymi spowodowało małe zmiany składu chemicznego roślin, zwłaszcza zawartości metali ciężkich. Jedynie osad z oczyszczalni mechaniczno-biologicznej wywołał znaczące różnice w zawartości składników w roślinach, głównie siarki i azotu.
In a pot experiment the influence of sewage sludge on the yield and chemical composition of plants was examined. Sludge originating from mechanical (MS) and mechanical-biological (BS) treatment plants was dosed into the soil according to an equivalent amount of nitrogen, which was 2 g per pot. The experiment was carried out on the lessive soil and the test plants were white mustard 'Nakielska' and white lupine 'Bardo'. The plants were harvested in the growth stage of full maturity. Based on the results of the experiment it was concluded that irrespective of the purification method, sewage sludge added to the soil influenced the yield and chemical composition of plants in various ways. The addition of sludge from mechanical-biological treatment plants to the soil resulted in a higher yield of mustard seed, whereas the sewage sludge from mechanical treatment plants increased the yield of lupine. Changes in the chemical composition of plants were small under sewage sludge application, which was especially seen in the case of heavy metals. Only the application of the sewage sludge from mechanical-biological treatment plant gave significant differences in macronu- trient (especially in sulphur and nitrogen) concentrations in plant organs.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2006, 6, 2; 87-97
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wplyw parametrow technologicznych na ilosc biomasy w reaktorze biologicznym ze zlozem ruchomym
Influence of technological parameters on biomass in moving bed biological reactor
Autorzy:
Makowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/40139.pdf
Data publikacji:
2007
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
reaktory z ruchomymi zlozami biologicznymi
reaktory biologiczne
osady czynne
blony biologiczne
biomasa
parametry technologiczne
oczyszczanie sciekow
active deposit
bacterial jelly
biological reactor
biomass
sewage treatment
technological parameter
Źródło:
Acta Scientiarum Polonorum. Architectura; 2007, 06, 2; 59-70
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ scieków miejskich i przemysłowych miasta Słupska na faunę denną rzeki Słupi
Vlijanie gorodskikh i promyshlennykh stokov goroda Slupska na donnuju faunu reki Slupi
The influence of sewage and industrial wastes of the city of Slupsk on the bottom fauna of the Slupia River
Autorzy:
Malej, J.
Powiązania:
https://bibliotekanauki.pl/articles/877003.pdf
Data publikacji:
1959
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
rzeka Slupia
scieki miejskie
scieki przemyslowe
Slupsk
wody rzeczne
fauna denna
badania fizykochemiczne
badania biologiczne
oczyszczanie sciekow
Slupia River
urban waste water
industrial sewage
Slupsk town
river water
bottom fauna
physicochemical research
biological investigation
sewage treatment
Źródło:
Roczniki Państwowego Zakładu Higieny; 1959, 10, 6
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan awaryjny reaktorów biologicznych A i B znajdujących się na oczyszczalni ścieków w Wałczu jako skutek popełnionych błędów przy ich projekcie i użytkowaniu
Emergency state of biological reactors located in the area of sewage treatment plant in Walcz as a result of commited faults during their projection process and expliotation
Autorzy:
Przybyłowicz, E.
Pikos, M.
Powiązania:
https://bibliotekanauki.pl/articles/160299.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
oczyszczalnia ścieków
zbiornik na ścieki
reaktor biologiczny
zbiornik żelbetowy
stan techniczny
pęknięcie
destrukcja betonu
analiza przyczyn
wastewater treatment plant
sewage tank
biological reactor
reinforced concrete tank
technical condition
crack
concrete destruction
causes analysis
Opis:
W pracy omówiono uszkodzenia i przyczyny, które doprowadziły do stanu awaryjnego dwóch reaktorów biologicznych na remontowanej oczyszczalni ścieków w Wałczu. Powstałe uszkodzenia ścian i den zbiorników stworzyły zagrożenie skażenia środowiska ściekami komunalnymi. Bezpośrednią przyczyną tego stanu były popełnione błędy na etapie projektowania konstrukcji zbiorników bez zachowania odpowiednich zasad odnośnie posadowienia, rozwiązań dylatacji, zbrojenia i wymagań co do jakości betonu. W reaktorach nie zastosowano odpowiednich powłok ochronnych na betonie, co w połączeniu ze złą jakością betonu doprowadziło do całkowitej degradacji obiektów i podjęcia decyzji o ich rozbiórce z uwagi na nieopłacalny remont.
Present paper discusses the damages and causes that led to the emergency condition of two biological reactors on the renovated sewage treatment plant in Walcz. Resulting damages of walls and bottom of tanks caused a risk of contamination of the environment with municipal sewage. The direct cause of this condition was mistakes/errors made at the stage of structural design of the tanks without maintaining proper rules of foundation process, construction of dilation, propositions of suitable reinforcements and concrete quality requirements. In the reactors appropriate protective coatings on a concrete were not used, which, in combination with poor quality of concrete, led to complete degradation of objects and decided to demolish them due to unprofitable repairs.
Źródło:
Przegląd Budowlany; 2017, 88, 9; 86-88
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie prątków grużlicy w ściekach, metody wykrywania i unieszkodliwiania przy oczyszczaniu ścieków
Vystupanie tuberkuliznykh palochek v stochnykh vodakh, metody obnaruzhivanija i obezvrezhivanija ikh vo vremja ochistki stochnykh vod
Occurence of tubercle bacilli in sewage, methods of enumeration and effect of sewage treatment
Autorzy:
Dozanska, W.
Powiązania:
https://bibliotekanauki.pl/articles/876114.pdf
Data publikacji:
1957
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
pratki gruzlicy
Mycobacterium tuberculosis
wystepowanie
scieki miejskie
scieki przemyslowe
scieki szpitalne
wody powierzchniowe
unieszkodliwianie sciekow
metody wykrywania
oczyszczanie sciekow
metody biologiczne
metody mikroskopowe
oznaczanie
tuberculosis
occurrence
urban waste water
industrial sewage
hospital sewage
surface water
waste water disposal
detection method
waste water treatment
biological method
microscopic method
determination
Źródło:
Roczniki Państwowego Zakładu Higieny; 1957, 08, 3
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-33 z 33

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies