Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Water analysis" wg kryterium: Temat


Tytuł:
Environmental Protection and Improvement of Water Quality as a Factor in the Development of Tourism in the Erenik River
Autorzy:
Gashi, Bardha
Kuqi, Beke
Dreshaj, Adem
Powiązania:
https://bibliotekanauki.pl/articles/24201792.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
parameter
river
urban discharge
water analysis
water quality
Opis:
This paper examines the impact of urban discharges on the water quality of the Erenik River in the city of Gjakova, Kosovo which is the most of key factor in developing the tourism. The primary goal of this project-based research was to provide results through water analysis in order to show the impact of urban discharges on the water quality for the tourists coming. The research was carried out by taking water samples at the entrance and exit of the Erenik River, while the measured parameters of the analyses were: temperature, pH value, electrical conductivity, turbidity, permanganates, phosphorus; and chlorides. Due to the conditions, measurements were not performed for: biological and chemical expenditure, dissolved oxygen, and alkalinity of the water. In order to achieve reliable results, the experimental research model was used, applying the techniques and methods of water analysis during the period of November-December 2021. The analyzed water result and the final findings showed that urban wastes affect the water quality, in particular the pollution from the discharges in the river potentiating the condition in which the Erenik River is found.
Źródło:
Journal of Ecological Engineering; 2023, 24, 3; 333--340
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A modification of existing methods of sample collection in the fungal analysis of water
Autorzy:
Biedunkiewicz, A.
Korycinska, J.
Kubiak, K.
Dzika, E.
Powiązania:
https://bibliotekanauki.pl/articles/5586.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
modification
existing method
sample collection
fungal analysis
water analysis
surface water
Źródło:
Annals of Parasitology; 2016, 62, Suppl.
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physico-Chemical Properties of Sri Sanishwaran Temple Pond Water, Tirunallar
Autorzy:
Ganesh, K. Sankar
Xavier, R. Lawrence
Nagarajan, M.
Sundaramoorthy, P.
Powiązania:
https://bibliotekanauki.pl/articles/1193934.pdf
Data publikacji:
2015
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Devotees
Physico-chemical properties
Saneshwaran temple
Water analysis
Opis:
Tirunallar Saniswaran Temple dedicated to Lord Darbaranyeswaran, a form of Lord Shiva. Temple management imposes restrictions over misuse of these holy ponds. The devotees use the holy water for washing their limbs before entering the temple. Sometimes they make a holy dip into the water; people believe that it can wash all their sins away. Thousands of devotees visit the temple. So, the present investigation deals with the physiochemical properties of Sri Saneeshwaran temple pond water. Analysis of water samples revealed that the physico chemical properties such as pH , Electrical conductivity, Total hardness (mg/l), Ca hardness (mg/l), Mg hardness (mg/l), BOD (mg/l), Total Dissolved solids (mg/l), Suspended solids (mg/l), Chlorides (mg/l), Sulphate (mg/l), Sodium (mg/l), Potassium (mg/l), Dissolved Oxygen (mg/l) and Oil & grease (mg/l)., is varied significantly. Similarly the bacterial load is higher in after mass bathing than in before mass bathing.
Źródło:
World Scientific News; 2015, 21; 1-11
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ion chromatography - a method of choice for the determination of ionic species in waters and waste waters
Chromatografia jonowa - metoda oznaczania jonowych składników wód i ścieków
Autorzy:
Michalski, R.
Janiszewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/964060.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
ion chromatography
water analysis
waste water analysis
inorganic ions
standardization
chromatografia jonowa
analiza wody
analiza ścieków
jony nieorganiczne
normalizacja
standardyzacja
Opis:
Water and wastewater are an important part of chernical analysis. The development of new methods and improvement of existing ones is a major task for analytical chernists. There is a need for reliable identification and monitoring of many substances present in water and wastewater in order to prevent contarnination and protect the environment. Substances occurring in different types of water may be classified as biological, chernical (both inorganic and organie), physical, and radiological impurities. Inorganic anions and cations are the most frequently deterrnined in many laboratories in routine analysis. łon chromatography is an attractive technique for the deterrnination of ionic species, especially for laboratories that need to deterrnine numerous anions and cations in severa! thousand samples, but do not have the throughput to justify the purchase of large automatic analysers, usually based on colorimetric procedures. łon chrmnatography eliminates the need to use hazardous reagents, which are often integral to wet chemical methods. The demands from regulators for justifiable analytical results and from laboratories for validated methods provide the necessity to standardize ion chromatographic methods.
Badania wód i ścieków stanowią istotny element analizy chemicznej. Rozwój nowych metod i ulepszanie istniejących to główne zadanie chemików analityków. Istnieje potrzeba ścisłej kontroli i monitorowania wielu substancji obecnych w wodzie i ściekach, żeby zapobiegać zanieczyszczeniu środowiska i chronić go. Substancje zawarte w różnych rodzajach wód mogą być klasyfikowane jako biologiczne, chemiczne (zarówno nieorganiczne, jak i organiczne), fizyczne i zanieczyszczenia radiologiczne. W wielu laboratoriach w ramach rutynowej analizy najczęściej oznaczane są nieorganiczne aniony i kationy. Chromatografia jonowa jest atrakcyjną techniką, szczególnie dla laboratoriów, które muszą oznaczać wiele anionów i kationów w kilku tysiącach próbek, jednak nie posiadają tak dużej wydajności, żeby uzasadnić zakup dużych automatycznych analizatorów, zwykle opartych na procedurach kolorymetrycznych. Chromatografia jonowa eliminuje potrzebę stosowania szkodliwych odczynników, które są często integralną częścią klasycznej chemicznej analizy. Żądania ze strony jednostek nadzorujących uzasadnianie analitycznych wyników oraz ze strony laboratoriów zwalidowanych metod doprowadziły do konieczności standardyzacji metod oznaczania z zastosowaniem techniki chromatografii jonowej.
Źródło:
Problemy Eksploatacji; 2016, 4; 93-106
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spatial Variability Analysis of Some Groundwater Physico-Chemical Parameters in Parts of Akwa-Ibom State, Nigeria
Autorzy:
Emujakporue, Godwin O.
Ngwueke, Marcel I.
Powiązania:
https://bibliotekanauki.pl/articles/1191777.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Water analysis
Akwa Ibom
Physico-chemical parameters
Semi-variogram
Kriging
Opis:
The groundwater physico-chemical parameters of Parts of Akwa Ibom state and their spatial distribution have been examined in this study. The physico-chemical parameters analysed are Ph, total dissolved solids, electrical conductivity and water hardness. The average pH, electrical conductivity, water hardness and total dissolved solids obtained are 6.4, 163.4242 μS/cm, 83.81 mg/l and 90.5 mg/l respectively. The computed values are within the permissible limit set by World Health Organisation (WHO). Semi-variogram and ordinary kriging were used for the spatial distribution analysis. The semi variogram of the pH, total dissolved solids, electrical conductivity and water hardness were model with Gaussian, spherical, linear functions respectively. The pH map is dominated with values ranging from 6.2 to 6.6 while the total dissolved solids map is associated mainly with values ranging from 90 to 95 mg/l. The water hardness and electrical conductivity values increases from central part toward the west and eastern regions. The geostatical modelling has been used to estimate the values of the parameters at unsampled points.
Źródło:
World Scientific News; 2016, 50; 20-32
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fizykochemiczne właściwości wybranych źródlisk Puszczy Knyszyńskiej
Physico–chemical state of selected springs in Knyszyn Forest
Autorzy:
Chomutowska, H
Kryjan, T
Powiązania:
https://bibliotekanauki.pl/articles/401106.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
źródło
nisza źródliskowa
wypływ
analiza wody
spring
spring niche
outflow
water analysis
Opis:
Źródła jako wypływy wód podziemnych na powierzchnię gruntu należą do trwałych elementów w krajobrazie Parku Krajobrazowego Puszczy Knyszyńskiej, wynikały z geologicznej budowy Wysoczyzny Białostockiej. Przedmiotem badań były źródła rezerwatów Krzemianka, Jałówka i Budzisk tego Parku. Dokonano klasyfikacji źródeł oraz analizy wody z określeniem jej cech fizyczno-chemicznych. Badania dowiodły, że dominują tu źródła krawędziowe, ascensyjne lub descensyjne, które jednocześnie zalicza się do reokrenów. Z racji położenia większości źródeł na terenach leśnych oraz braku zmian antropogenicznych woda ze źródeł odznacza się tu dobrą jakością.
Springs as groundwater outflows onto the surface belong to permanent elements in Knyszyn Forest Landscape Park which occurrence results from geological structure of Białystok High Plain. Research included 5 springs located in 3 reserves (Krzemianka, Jałówka, Budzisk) in Knyszyn Forest Landscape Park. During research there have been described classification of springs with water analyses of physico-chemical properties as well as flora verification in spring niches. The surveys has shown that in studied area the springs belong to ascending or descending outflows with erosion scarp and rheocrenes at one time. Due to lack of anthropogenic changes as well as location of springs in forest area they possess good water quality here what was proved by water analyses.
Źródło:
Inżynieria Ekologiczna; 2014, 37; 50-61
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gamma radiations in surface and groundwaters of the Rugia Island
Źródła promirniowania gamma w wodach powierzchniowych i gruntowych Rugii
Autorzy:
Janukowicz, H.
Wira, J.
Powiązania:
https://bibliotekanauki.pl/articles/85055.pdf
Data publikacji:
1999
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
gamma-radiation
surface water
ground water
Rugia Island
sea water
river water
reservoir water
drinking water
water analysis
radioactivity
monitoring
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 1999, 03
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wody z Rabe. Cz. 2
Autorzy:
Chorostyński, A.
Łach, A.
Pasztyla, G.
Powiązania:
https://bibliotekanauki.pl/articles/274440.pdf
Data publikacji:
2016
Wydawca:
Roble
Tematy:
analiza wody
woda mineralna
woda lecznicza
wody litowo-arsenowe
Rabe
water analysis
mineral water
healing waters
Źródło:
LAB Laboratoria, Aparatura, Badania; 2016, 21, 1; 44-49, 52
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The elements of specific biological activity in therapeutic waters in Polish health resorts
Pierwiastki o swoistej aktywności biologicznej w wodach leczniczych polskich uzdrowisk
Autorzy:
Drobnik, M.
Latour, T.
Sziwa, D.
Powiązania:
https://bibliotekanauki.pl/articles/15029.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Tematy:
Polska
therapeutic water
specific biological activity
biological activity
health resort
sulphide
iodide
fluoride
iron
silicon
radon
carbon dioxide
physicochemical analysis
water analysis
Opis:
The study characterizes specific therapeutic waters in Polish health resorts, which contain iodide, fluoride, silicon, sulphides, iron(II), carbon dioxide and radon in concentrations that ensure the therapeutic status of water and specify how it can be used for medical treatment. Based on the physicochemical analysis, it has been verified that among 160 waters from 39 health resorts, 37 contain Fe(II) in concentrations > 10 mg dm–3, which means that they can be classified as ferruginous. Twelve waters containing fluoride in concentrations > 2 mg dm–3 were recognized as therapeutic fluoride waters. Five waters were classified as siliceous ones owing to the content of silicon compounds above 70 mg dm–3 (H2SiO3). Twenty-eight of the analysed waters contain sulphides (H2S+HS–) in concentrations > 1 mg dm–3 and 64 waters contain iodide in concentrations > 1 mg dm–3. Carbon dioxide, which occurs in 72 waters in concentrations above 1 g dm–3 (acidulous waters), proved to be the most widespread component. Waters which contain radon in an amount corresponding to the radiation of 74 Bq (2 nCi) in 1 dm3 are classified as radon waters. Ten of the analysed waters were found to contain this element. The waters were highly varied in chemical composition and type of specific components. Sulphurous waters are mainly used for mineral baths; ferruginous waters are drunk; fluoride and silicon-rich waters are taken for mineral baths and iodide waters are used for mineral baths and inhalations. Using these waters in balneotherapy is an important part of spa treatment and defines different healing profiles of Polish health resorts.
W pracy przedstawiono charakterystykę leczniczych wód swoistych polskich uzdrowisk. Są to wody zawierające jodki, fluorki, związki krzemu, związki siarki (II), żelazo (II), dwutlenek węgla i radon w stężeniach decydujących o statusie leczniczym wody i sposobie jej wykorzystania do zabiegów kuracyjnych. Na podstawie wyników analiz fizykochemicznych stwierdzono, że spośród 160 wód pochodzących z 39 miejscowości uzdrowiskowych 37 wód zawiera żelazo (II) w stężeniu > 10 mg dm–3 wymaganym dla uznania wody za żelazistą 12 wód zawierających fluorki w stężeniu > 2 mg dm–3 uznano za lecznicze wody fluorkowe; 5 wód ze względu na zawartość związków krzemu w stężeniu > 70 mg dm–3 (H2SiO3) zaliczono do wód krzemowych; 28 wód zawiera związki siarki (II) w stężeniu > 1 mg dm–3 (HS– + H2S), a 64 wody zawierają jodki w stężeniu > 1 mg dm–3. Najczęściej występującym składnikiem swoistym wód leczniczych jest dwutlenek węgla, którego stężenie w 72 wodach przekracza 1 g dm–3 (szczawy). Wody zawierające radon w ilości, której odpowiada aktywność promieniotwórcza co najmniej 74 Bq dm–3 (2 nCi), są zaliczane do wód radonowych. Pierwiastek ten występuje w 10 badanych wodach. Omawiane wody charakteryzują się dużym zróżnicowaniem podstawowego składu chemicznego oraz zawartością ww. składników swoistych. Wody swoiste siarczkowe są wykorzystywane głównie do kąpieli, wody żelaziste do kuracji pitnych, wody fluorkowe i krzemowe do kąpieli, a jodkowe do kąpieli i inhalacji. Stosowanie tych wód w balneoterapii stanowi ważną część działalności uzdrowiskowej i uzasadnia różne profile lecznicze polskich uzdrowisk.
Źródło:
Journal of Elementology; 2011, 16, 4
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekstrakcja micelarna cymetydyny
Micellar extraction of cimetidine
Autorzy:
Kiszkiel-Taudul, I.
Powiązania:
https://bibliotekanauki.pl/articles/1208675.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
cymetydyna
ekstrakcja micelarna
SDS
Tween-80
analiza wód powierzchniowych
cimetidine
micellar extraction
surface water analysis
Opis:
W pracy przedstawiono procedurę ekstrakcji micelarnej cymetydyny (CMT) w celu efektywnego jej wydzielenia z próbki wodnej. Badany związek należy do grupy leków przeciwhistaminowych i jest szeroko stosowany w terapii schorzeń układu pokarmowego. W przeprowadzonych badaniach, ekstrakcję micelarną CMT przeprowadzono z udziałem dwóch surfaktantów: dodecylosiarczanu-(VI) sodu (SDS) oraz Tween-u 80 (TW-80). Wyznaczono parametry analityczne spektrofotometrycznych metod oznaczania cymetydyny w zakresie UV. Opracowane procedury zastosowano do sprawdzenia obecności badanego analitu w próbkach naturalnych.
The presented paper describes an elaboration of micellar extraction procedures for effective isolation of cimetidine (CMT) from aqueous samples. This antihistamine drug is widely applied for treatment diseases of stomach. The micellar extraction of cimetidine was performed with using sodium dodecylsulfate(VI) and Tween-80 (TW-80). The analytical parameters of spectrophotometric (UV) determination of the studied compound were calculated. The elaborated methods following by micellar extraction procedures were used for the analysis of cimetidine in natural water samples.
Źródło:
Chemik; 2016, 70, 2; 105-110
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development and Validation of a GC-MS Method for the Simultaneous Quantitation of Zearalenone and Its Metabolites in Water
Opracowanie i walidacja metody GC-MS do równoczesnego oznaczania zearalenonu i jego metabolitów w wodzie
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388081.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
zearalenon
metabolity
mykoestrogeny
SPE
GC-MS
oznaczanie
analiza wody
zearalenone
metabolites
mycoestrogens
determination
water analysis
Opis:
The method of simultaneous determination of zearalenone and its metabolites in water with use of GC-MS chromatography was evaluated. The solid phase extraction SPE was used for analytes separation from water and as an enrichment method. The influence of compounds concentration and water sample volume on analytes recovery was investigated. The chromatographic analysis was preceded by conversion of compounds to trimethylsilyl ethers derivatives. The developed SPE-derivatization-GC/MS method allow to separate quaternary mixture of mycoestrogens with the quantitative analysis in water, when their concentration is greater than 0.2–0.5 ng/dm3. The repeatability of the results was from 1 to 8 %. The recovery of compounds exceeded 60 % for samples contains from 50 to 200 ng/dm3 of mycotoxins. The concentration of analytes and volume of the sample (100–500 cm3) did not have an influence on the extraction output. The developed method can be applied to analyze water samples containing mycoestrogens at the level of ng/dm3.
Ocenie poddano metodę równoczesnego oznaczania zearalenonu i jego metabolitów w wodzie z użyciem chromatografii GC-MS. Ekstrakcja do fazy stałej SPE wykorzystana została jako metoda wydzielania i wzbogacania analitów z wody. Badano wpływ stężenia i objętości próbki wody na odzysk związków. Z kolei przed chromatograficznym oznaczeniem mykoestrogeny przeprowadzono w etery trimetylosiliowe. Metoda SPE-derywatyzacja-GC/MS umożliwia rozdział czteroskładnikowej mieszaniny mykoestrogenów i ich ilościowe oznaczenie w wodzie na poziomie stężeń 0,2–0,5 ng/dm3. Powtarzalność oznaczeń była w zakresie 1–8 %. Wyznaczony odzysk związków dla stężenia w zakresie 50–200 ng/dm3 przekraczał 60 %. Nie obserwowano znacznego wpływu stężenia analitów jak i objętości próbki wody (100–500 cm3) na wydajność ekstrakcji. Przedstawioną metodykę można więc zastosować do kontroli analitycznej obecności mykoestrogenów w środowisku wodnym na poziome stężeń ng/dm3.
Źródło:
Ecological Chemistry and Engineering. A; 2010, 17, 11; 1397-1404
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki wpływające na koszt jednostkowy pozyskania wody dla gospodarki komunalnej w Polsce
Factors Affecting an Individual Cost of Water Supply for Municipalities in Poland
Autorzy:
Bartoszczuk, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/500492.pdf
Data publikacji:
1998
Wydawca:
Szkoła Główna Handlowa w Warszawie
Tematy:
Gospodarka wodna, Gospodarka komunalna, Analiza zużycia wody, Gospodarowanie zasobami wody
Water management, Public utilities, Water consumption analysis, Water resources development
Opis:
Artykuł poświęcony jest problemom gospodarki wodnej, a w szczególności analizie wyników badań dotyczących kosztów pozyskiwania wody dla odbiorców w polskich miastach w latach dziewięćdziesiątych oraz analizie czynników wpływających na te koszty.
Water supply process includes water abstraction, water treatment services, water distribution network. City inhabitants, industrial units or individual production units relay on the process to get water for their use. Empirical data have indicated that individual cost of water supply strongly depends on the size of both industrial units and the city area. The city size can affect the cost in two opposing ways; positive as together with the increase in area the efficiency of the supply network utility increases, or negative as the increase in area means longer distances of the water distribution network to cover. (J.W.)
Źródło:
Prace i Materiały Instytutu Rozwoju Gospodarczego SGH; 1998, 59; 95-110
0866-9503
Pojawia się w:
Prace i Materiały Instytutu Rozwoju Gospodarczego SGH
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FEM calculations in analysis of steel subsea water injection flowlines designing process
Autorzy:
Wodtke, M.
Olszewski, A.
Wójcikowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/259856.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
offshore engineering
water injection flowlines analysis
FEM simulation
Opis:
The article describes the result of theoretical research aimed at assessing the loads and operating conditions of a Coiled Tubing pipeline injecting water, suspended to the mining platform of Lotos Petrobaltic. For this purpose, appropriate calculation models have been developed using the Finite Element Method (FEM), taking into account the nature of the analyzed object and its loads. The analyzes were carried out for two pipes (previously operated and newly proposed) differing in geometrical and strength parameters. The research was carried out for selected directions of load on the pipeline (originating from sea waves) and various variants of attaching the suspended pipeline to the mining platform.
Źródło:
Polish Maritime Research; 2018, 3; 84-93
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Towards automation of measurement processes of surface water parameters by a remote-controlled catamaran
Autorzy:
Wiora, A.
Kozyra, A.
Wiora, J.
Powiązania:
https://bibliotekanauki.pl/articles/201946.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
measurement automation
remote controlled boat
environmental water analysis
potentiometry
automatyka pomiarowa
zdalnie sterowana łódź
analiza środowiska wodnego
potencjometria
Opis:
This paper describes a way of determining selected water parameters using a prototype of a remote-controlled catamaran. The remote controlling allows to steer the boat and to manage the measurement process from the shore. It is possible to monitor the water parameters online as well as to store them and analyze them afterwards. The measured parameters are determined mainly using potentiometric methods and include several ion concentrations. The system is orientated towards monitoring breeding ponds or other similar surface waters. The mechanical construction of the catamaran, its electronic circuits and implemented software are described in detail in the paper. Conclusions obtained from preliminary tests are also included. The described construction allows analysts to perform simple and inexpensive remote measurements or assessments of water quality and reduces the time of such analysis in comparison to traditional sampling.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 3; 351-359
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of land use on the water quality of foothill microcatchment areas
Wpływ użytkowania terenu na jakość wód mikrozlewni podgórskich
Autorzy:
Misztal, A.
Kuczera, M.
Powiązania:
https://bibliotekanauki.pl/articles/81573.pdf
Data publikacji:
2008
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
land use
water quality
catchment area
foot-hills
small stream
stream
water analysis
nitrate
nitrite
ammonia
phosphate
sulphate
chloride
calcium
magnesium
conductivity
oxygen
Źródło:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation; 2008, 40
0208-5771
Pojawia się w:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Morphological and Morphogenetic Redescriptions and SSU rRNA Gene-based Phylogeny of the Poorly-known Species Euplotes amieti Dragesco, 1970 (Ciliophora, Euplotida)
Autorzy:
LIU, Mingjian
FAN, Yangbo
MIAO, Miao
Hu, Xiaozhong
Al-Rasheid, Khaled A. S.
Al-Farraj, Saleh A.
Ma, Honggang
Powiązania:
https://bibliotekanauki.pl/articles/763760.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Jagielloński. Wydawnictwo Uniwersytetu Jagiellońskiego
Tematy:
Euplotidae, fresh water ciliate, ontogenesis, phylogenetic analysis, taxonomy
Opis:
This paper investigates the morphology and morphogenesis during binary fission of a Chinese population of Euplotes amieti Dragesco, 1970, a fresh water form which has previously not been well defined. This organism is morphologically very similar to the well-known Euplotes eurystomus but differs from the latter both in the number of dorsal kineties and the molecular data. According to the information obtained, it is characterized by a combination of features including nine frontoventral cirri, ca. 60 membranelles, 12–15 dorsal kineties, a macronucleus in the shape of the number 3, and a ‘double-eurystomus’ type of silverline system. Its morphogenesis proceeds broadly in the same pattern as in its congeners. In this study, the SSU rRNA gene was sequenced for the first time, and phylogenetic analyses indicated that it is closely related to the eurystomus-aediculatus-woodruffi- complex. Considering the extreme similarities in morphology between E. amieti and E.eurystomus, we believe that the four sequences (four isolates) under the name of Euplotes eurystomus (No. FR873716; FR873717; EF193250; AJ310491 deposited in GenBank) are very likely from misidentified material; that is, they represent different populations of Euplotes amieti.
Źródło:
Acta Protozoologica; 2015, 54, 3
1689-0027
Pojawia się w:
Acta Protozoologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of reasons of the water contamination on the intake in Wolin including the recovery measures preventing the similar contamination
Ustalenie przyczyn skażenia wody na ujęciu w Wolinie wraz z podaniem środków zaradczych zapobiegających podobnemu skażeniu
Autorzy:
Wira, J.
Wira, D.
Powiązania:
https://bibliotekanauki.pl/articles/84919.pdf
Data publikacji:
2005
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
determination
reason
water contamination
Rybacka Street
20th century
prevention
Wolin town
water intake
water supply station
pumping unit
hydrophore tank
building
household building
water sample
testing
water analysis
chloride concentration
Opis:
The water intake situated at Rybacka Street in Wolin was established in the beginning of the 20th century. It is situated in the close vicinity of the existing apartment and business buildings and the water and sewage systems as well. On the fenced parcel ca 50x80 m besides the objects of: – building of the water-supply station, – warehouse – workshop building with sanitary facilities, – household building, – building of the current generating plant, are situated the deep-water wells No. 6 and No. 9 now in the operational use. The other deep-water wells being now in the operational use are the well No. 10 situated at Rybacka Street in the distance ~ 90 m from the intake parcel border as well as the well No. 5 situated in the distance ~ 220 m from the parcel border.
Zasadniczym czynnikiem, który był powodem zanieczyszczenia wody na ujęciu w Wolinie było skażenie warstwy wodonośnej prowadzonymi w roku 2003 robotami hydrotechnicznymi na nabrzeżu Dziwnej. Biorąc pod uwagę fakt ustania przyczyny skażenia ujęcia, potwierdzony uzyskiwanymi badaniami wody surowej uważamy, że dalsze stałe prowadzenie dezynfekcji wody jest bezzasadne. Zakładając, że zjawisko skażenia warstwy wodonośnej może w przyszłości wystąpić (powtórzyć się), uważamy za zasadne ciągle monitorowanie jakości wody ujmowanej (surowej).
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2005, 09
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Internal Corrosion Damage Mechanisms of the Underground Ferrous Water Pipelines
Autorzy:
Yeshanew, Desalegn A.
Jiru, Moera G.
Lemu, Hirpa G.
Tolcha, Mesay A.
Powiązania:
https://bibliotekanauki.pl/articles/2201765.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
internal corrosion
water pipes
water physico-chemical analysis
corrosion mechanisms
corrosion mechanism
Opis:
Internal water pipe corrosion is a complicated problem due to the interaction of water quality parameters with pipe wall. This study presents investigations of internal pipe surface corrosion mechanisms related to water physicochemical. Samples of water and corrosion-damaged ductile cast iron (30+ years) and galvanized steel pipe (15-20 years) were collected at in-situ condition from Addis Ababa city water distribution system. Scanning electron microscopy and optical microscopy were used to examine the pipes' corrosion morphology and microstructures, respectively. Additionally, Mountains 9 surface analysis software was used for further pitting corrosion characterization.To identify the causes of internal pipe corrosion, water physicochemical analyses were conducted by using inoLab pH 7310P, DR 900, Palintest Photometer 7100, and Miero 800. Water physicochemical test indicates: CaCO3 is 77 - 215 ppm, pH is 7.05 – 7.86, total dissolved solids (TDS) is 84.10 -262.8 ppm, ClO2 is 0 – 0.5 ppm, and dissolved oxygen (80-81 ppb). From water test results, major causes of internal pipe corrosion damage mechanisms were identified as dissolved oxygen, CaCO3, TDS, ClO2,and resistivity of water which initiates a differential cell that accelerates pipe corrosion. Using Mountain 9 surface analysis software, corrosion morphology and pitting features were characterized. The outputs of this paper will be helpful for water distribution and buried infrastructure owners to investigate corrosion damage mechanisms at early stage. To manage corrosion mechanisms, water supply owners need to conduct frequent inspections, recording of pipe data, testing of water quality, periodic pipelines washing, and apply preventative maintenance.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 3; 111--123
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and assessment of technological processes of the Miedwie Lake surface water treatment plant for the city of Szczecin
Analiza i ocena procesów technologicznych stacji uzdatniania wody powierzchniowej z jeziora Miedwie dla miasta Szczecina
Autorzy:
Wira, J.
Wira, D.
Powiązania:
https://bibliotekanauki.pl/articles/84845.pdf
Data publikacji:
2005
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
technological process
Lake Miedwie
surface water
water treatment plant
Szczecin city
protection zone
lake water
tributary
raw water
clean water
water parameter
water analysis
water temperature
chloride
chemical oxygen demand
oxidizability
pH reaction
alkalinity
carbon dioxide
Opis:
Miedwie Lake is the biggest post-glacial lake of the West-Pomeranian Voievodship. At the same time it is the fifth of the largest lakes in Poland. As regards the geographical situation, Miedwie Lake is situated centrally between three big agglomerations i.e. Szczecin, Stargard Szczecinski and Pyrzyce (Fig. 1). The lake lies on the territory of three municipalities: Pyrzyce and Warnice in the District of Pyrzyce as well as Stargard Szczecinski in the District of Stargard (Rozmiarek 1983, Szyper 1990). At the moment, the reservoir is characterised with the regular, prolonged shape resembling an ellipse. Banks are shallow, regular and sometime very wet. The lake has the belt of the nearshore reaching locally tens metres far from the lake bank, what is the reason, together with the fact that the wind blows always here, that it is convenient for practising the various kinds of water sports. The lake area amounts to 3 527 ha; maximal depth – 43.8 m; average depth – 19.3 m; water capacity – 681.7 mln m3; shore-line length – 38.8 km; water level datum 14.1 m above sea level; maximal width 3.16 km; maximal length 16.2 km. The lake’s bottom is the lowest situated area on the territory of Poland.
Ujecie wody „Miedwie” powstało w roku 1976. Do tego czasu wody jeziora odpowiadały pierwszej klasie czystości. Jednakże jakość wody zaczęła się pogarszać już po rozpoczęciu eksploatacji ujęcia, dochodząc aż do poziomu trzeciej klasy czystości. Przyczyną był brak oczyszczalni oraz PGR-y. Zanieczyszczenie zbiornika powodowało masowe śniecią ryb (siei miedwiańskiej), przy dnie pojawił się siarkowodór, masowo zakwitały glony. Dalsze pogarszanie się stanu jeziora groziło zamknięciem ujęcia wody oraz wyniszczeniem życia biologicznego w zbiorniku, jak również wokół niego. Spadek jakości wód jeziora spowodowany był kilkoma czynnikami: rolnictwo, baza rosyjska w Kluczewie, turystyka, dopływy jeziora, biomanipulacja wodami Miedwia.
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2005, 09
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porownawcze bakteriologiczne badanie wody w kapieliskach woj.szczecinskiego wykonane wg metodyki stosowanej w polnocnych landach Republiki Federalnej Niemiec i metodyki Panstwowego Zakladu Higieny
The comparative bacteriological examinations of the bathingwaters in Szczecin province, performed by methods using in nothern lands of Germany and Panstwowy Zaklad Higieny
Autorzy:
Torun, D
Dziurzynska, F.
Powiązania:
https://bibliotekanauki.pl/articles/871233.pdf
Data publikacji:
1993
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
kontrola sanitarna
stacje sanitarno-epidemiologiczne
woj.szczecinskie
wody powierzchniowe
analiza wody
analiza mikrobiologiczna
kapieliska
kontrola jakosci
zanieczyszczenia srodowiska
zanieczyszczenia wod
sanitary control
sanitary-epidemiological station
Szczecin voivodship
surface water
water analysis
microbiological analysis
bathing site
quality control
environment contaminant
water contaminant
Opis:
Wykonano równoległe badania bakteriologiczne próbek wody w kąpieliskach zgodnie z metodyką Państwowego Zakładu Higieny, stosowaną przez stacje sanitarno-epidemiologiczne w Polsce i metodykę opracowaną przez zespół specjalistów niemieckich w nadmorskich Landach Republiki Federalnej Niemiec. Porównano wytyczne kontroli sanitarnej jakości wody w kąpieliskach, obowiązujące w Polsce z wytycznymi EWG.
For the purpose of this work was the comparison of the obligatory diretive lines using by sanitary - epidemic station in Poland and confrontation with EWG Guideline and comparison of the bacteriological examinations methods of surface waters using in Poland and northern Lands of Germany. The parallel examination of 120 water samples, according to PZH method and the method, using broth's Brila - MUG, preparated by the group of german specialists, were performed. The equivalent results in 60% of tested sampels were obtained. If confirmed on purpose the preparating of uniform directive lines and evaluation criterium for maritime and inland bathing waters, according to EWG Guidline, and as well as taking into consideration possibility of application the method with Brila MUG broth to bacteriological examination of maritime bathing waters at first.
Źródło:
Roczniki Państwowego Zakładu Higieny; 1993, 44, 2-3; 221-225
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of the Triad Approach to Ecological Assessment of the State of a Reservoir Receiving Wastewater From a Thermal Power Plant
Autorzy:
Mahanova, Elena
Powiązania:
https://bibliotekanauki.pl/articles/1839092.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
thermal power plant
chemical analysis of water
bioassay
bioindication
pollution
trophicity
Opis:
Thermal power plants (TPP) belong to the enterprises that accompany the development of any city. These industrial facilities consume and discharge large amounts of water. Therefore, thermal power plants are often located near water bodies that need to assess their ecological state and predict the consequences of the anthropogenic impact. The purpose of the work was to assess the ecological state of the floodplain Lake Ivanovskoye (Russia, Kirov region), which receives the wastewater from a thermal power plant, using a triadic approach and comparing the results of chemical analysis, bioassay and bioindication. It was shown that the main pollutant in the lake and the canal connecting Lake Ivanovskoye with the nearest river Vyatka is ammonium ion (up to 3.2 mg/dm3). In addition, the Russian standards for biological oxygen consumption are exceeded (analysis period is 20 days). The tests for the toxicity of wastewater showed inhibition of Paramecium caudatum and Escherichia coli reactions. In contrast, natural surface water from Lake Ivanovskoye stimulated the test functions of Scenedesmus quadricauda, P. caudatum, and E. coli. The death of Daphnia magna in the samples were not recorded. The totality of the facts pointed to the organic nature of pollution, leading to the anthropogenic eutrophication of the lake. The hypothesis was tested by using the bioindication method and by analyzing the totality of species of coastal aquatic plants. It was shown that the reservoir belongs to the mesotrophic type with a moderate degree of pollution, which decreases with distance from the wastewater discharge points. The increase in the trophicity of the reservoir is facilitated by thermal pollution (up to +15℃) and an alkaline pH of wastewater (up to 9.2). Thus, the joint analysis of the results of chemical analysis, bioassay and bioindication made it possible to carry out an objective assessment of the ecological state of the reservoir and identify the reasons for the revealed facts.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 155-160
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of water scarcity on households’ livelihoods in Iwoye-Ketu Area of Ogun State, Nigeria
Wpływ deficytu wody na poziom życia w gospodarstwach domowych na obszarze Iwoye-Ketu w nigeryjskim stanie Ogun
Autorzy:
Aromolaran, Adetayo K.
Ademiluyi, Ibiyinka O.
Sotola, Abiodun E.
Wole-Alo, Felicia I.
Aromiwura, Oluwadamilola A.
Ogunsuyi, Olubukola E.
Powiązania:
https://bibliotekanauki.pl/articles/292360.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
Iwoye-Ketu
livelihoods
perceived effects
water quality analysis
water scarcity
water sources
analiza jakości wody
deficyt wody
odczuwane skutki
poziom życia
źródła wody
Opis:
Water is an essential commodity which affects life and livelihoods in the universe. This study examined perceived effect of water scarcity on livelihoods in Iwoye-Ketu, Ogun State. Random sampling was used to select 80 rural households and water samples for the study. Data collected were analysed using descriptive, inferential and laboratory analyses. Findings showed that the mean age of respondents was 38 years with an average household size of four persons. The major sources of water were boreholes (97.5%) and rainwater (90.0%), the average trekking time to the water source was 24 minutes and the households requires an average of 162 litres of water per day. Water analysis’ result showed that the water has pH (6.87), total dissolved solids (0.175 mg∙dm–3), temperature (29.9°C) and turbidity (0.6 FTU). The major causes of water scarcity include insufficient rainfall (97.5%), increased sunlight intensity (97.5%), pollution of water sources (95.0%) and increased population (93.8%). About 60% of them perceived water scarcity to have a negative effect on their livelihoods. Correlation analysis shows that there is a significant relationship between usage of water (r = 0.370, p < 0.01) and perceived effect of water scarcity. It was concluded that water available for household use is not sufficient, although it is safe but contain some elements which are not of World Health Organization standard for good potable water. It is recommended that the community should build a hub for water collection and distribution close to the village centre and the government should provide water infrastructures to increase the supply of potable water.
Woda jest podstawowym dobrem, które wpływa na życie i warunki życia na świecie. W przedstawionej pracy badano wpływ deficytu wody na poziom życia w Iwoye-Ketu w stanie Ogun. Do badań losowo wybrano 80 wiejskich gospodarstw i próby wody. Zebrane dane analizowano za pomocą metod opisowych, wnioskowania i metod laboratoryjnych. Średni wiek respondentów wynosił 38 lat, a średnia wielkość gospodarstwa – 4 osoby. Głównym źródłem wody były studnie wiercone (97,5%) i opady deszczu (90,0%). Średni czas dojścia do źródła wody wynosił 24 minuty, a gospodarstwa zużywały średnio 162 dm3 wody na dzień. Woda miała pH 6,87, sumę substancji rozpuszczonych 0,175 g∙dm–3, temperaturę 29,9°C i mętność 0,6 FTU. Do głównych przyczyn niedostatku wody zaliczano niewystarczające opady (97,5%), silne nasłonecznienie (97,5%), zanieczyszczenie źródeł wody (95,0%) i przeludnienie (93,8%). Około 60% respondentów uważało, że niedostatek wody wywiera ujemny wpływ na ich poziom życia. Analiza korelacji wykazała, że istnieje istotna zależność (r = 0,370, p < 0,01) między zużyciem wody a odczuciem negatywnego wpływu jej braku. Stwierdzono, że woda jest dostępna gospodarstwom w niedostatecznej ilości i choć bezpieczna, to zawiera pewne składniki, które nie spełniają norm Światowej Organizacji Zdrowia ustalonych dla wody pitnej. Zaleca się, aby lokalna społeczność zbudowała miejsce gromadzenia i dystrybucji wody blisko centrum wsi, a rząd powinien zapewnić infrastrukturę w celu poprawy zaopatrzenia w wodę pitną.
Źródło:
Journal of Water and Land Development; 2019, 43; 9-18
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the water distribution subsystem in the waterworks “X” in the light of its losses
Analiza podsystemu dystrybucji wody w zakładzie wodociągowym „X” w świetle jego strat
Autorzy:
Merc, K.
Powiązania:
https://bibliotekanauki.pl/articles/296881.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
water loss limitation
water losses
water loss analysis
IWA indicators
percentage index
infrastructure leakage index
ograniczenie strat wody
straty wody
analiza strat
wskaźniki IWA
wskaźnik procentowy
infrastrukturalny indeks wycieków
Opis:
The activities aiming at the limitation of frequently significantly high water losses in the distribution systems exploited by waterworks ought to be preceded by a complete water loss analysis. Components of the analysis should include the comprehensive water balance in the waterworks, as well as the collection of information on the water supply system itself (length, age, material, number of recipients, number of connections). The article aims at presenting the water loss analysis conducted in the “X” Waterworks’ distribution system. The analysis was prepared with the use of the indicators recommended by the International Water Association (IWA) and the percentage loss indicator in order to present the differences between the results obtained using the percentage indicator in relation to the remaining indicators. The average pressure prevailing in the water supply system exploited by the plant equals 35 mH2O. Based on the data obtained from the plant and the results of the analysis it can be observed that the waterworks undertakes activities aiming at the decrease of the water loss rates. It is proved by the reduction of the Infrastructure Leakage Index (ILI) from 4.93 (unacceptable rate) to 3.31 which, according to the IWA assessment classifies the system as very poor. Evaluating the water supply system according to the guidelines of the American Water Works Association (AWWA), it can be stated that in 2010 the condition of the system was very good and did not change in the following years for which the analysis was conducted. Based on the WBI Banding System’s guidelines, the evaluation of the water supply system’s condition is good in 2015, in the earlier years, however, the system’s condition is reported as weak. Due to the very serious nature of the water loss issue and with the aim of its highest possible restriction, the water supply system analysis is recommended to be done according to the most rigorous IWA guidelines.
Działania zmierzające do ograniczenia często bardzo wysokich strat wody w systemach dystrybucji eksploatowanych przez zakłady wodociągowe poprzedzone powinny być wykonaniem kompletnej analizy strat wody. Do elementów składowych analizy należy zaliczyć wykonanie kompleksowego bilansu wody w zakładzie, a także zebranie informacji na temat samej sieci wodociągowej (długość, wiek, materiał, liczba odbiorców czy też liczba przyłączy). Niniejszy artykuł ma na celu przedstawienie wykonanej analizy strat wody w systemie dystrybucji zakładu wodociągowego „X”. Analiza sporządzona została przy użyciu wskaźników zalecanych przez International Water Assotiation (IWA) oraz procentowego wskaźnika strat w celu zobrazowania różnic pomiędzy wynikami uzyskiwanymi z zastosowania wskaźnika procentowego w odniesieniu do pozostałych wskaźników. Średnie ciśnienie, jakie panuje w sieci wodociągowej eksploatowanej przez zakład, wynosi 35 mH2O. Na podstawie danych uzyskanych z zakładu oraz wyników przeprowadzonej analizy można stwierdzić, że zakład wodociągowy podejmuje działania zmierzające do obniżenia poziomu strat wody. O tym świadczy obniżenie infrastrukturalnego indeksu wycieków (ILI) z poziomu 4,93 (stan niedopuszczalny) do poziomu 3,31, co według oceny IWA klasyfikuje sieć jako znajdującą się w stanie bardzo słabym. Dokonując oceny sieci wodociągowej na podstawie wytycznych American Water Works Association (AWWA), stwierdzono, że w 2010 roku stan sieci oceniany był jako dobry, stan ten nie zmieniał się przez pozostałe lata, dla których przeprowadzono analizę. Ocena stanu sieci przeprowadzona z zastosowaniem wytycznych WBI Banding System ukazuje stan sieci jako dobry w 2015 roku, natomiast w latach wcześniejszych według wytycznych sieć znajduje się w stanie słabym. Zaleca się ocenę sieci wodociągowych w oparciu o najbardziej rygorystyczne wytyczne IWA ze względu na bardzo poważny problem, jakim są straty wody, w celu ich wyeliminowania w możliwie najwyższym stopniu.
Źródło:
Inżynieria i Ochrona Środowiska; 2017, 20, 2; 199-209
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surveys of consumer preferences of the operation and management of water supply
Badania sondażowe preferencji konsumenckich na temat funkcjonowania oraz zarządzania dostawą wody
Autorzy:
Pietrucha-Urbanik, K.
Studziński, A.
Powiązania:
https://bibliotekanauki.pl/articles/388216.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
water network
consumer assessment
water supply system functioning analysis
sieć wodociągowa
ocena konsumencka
analiza funkcjonowania systemu zaopatrzenia w wodę
Opis:
The permanent and long-lasting development of the civilization influences the growth of the threat occurrence connected with the functioning of Water Supply System (WSS). The presented methodology can be used to describe the functioning of the public water supply using the evaluation of its proper functioning and allows for implementation to determine proper operation of water network. The expanded methodology of conducted surveys of recipients in the field of the effectiveness of the water supply system is the basis for a comprehensive assessment of its proper functioning. Consumer opinions may be used in determining water supply reliability standards and the rules for granting discounts and rebates in the case of restrictions and interruptions in water supply. A significant issue is the assessment by respondents nuisance interruptions in water supply (time and frequency), knowledge of the causes, inconveniencing and losses that causes lack of water supply. In the work the results of consumer survey during undesirable events in Polish water networks were presented.
Stały i długotrwały rozwój cywilizacji wpływa na wzrost występowania zagrożeń związanych z funkcjonowaniem systemu zaopatrzenia w wodę (SZW). Prezentowana metodologia może być stosowana w celu oceny prawidłowego funkcjonowania wodociągów. Opinie konsumentów mogą być stosowane przy określaniu standardów niezawodności usług wodociągowych oraz zasad udzielania bonifikat i upustów w przypadku ich niedotrzymania. Ważnym zagadnieniem jest ocena przez respondentów uciążliwości (czasu oraz częstotliwości), uniedogodnień, a także wielkości strat finansowych spowodowanych brakiem dostawy wody. W pracy przedstawiono wyniki badań oceny konsumentów podczas zdarzeń niepożądanych w polskich systemach wodociągowych.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 3; 299-311
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microflora of the selected water reservoirs in Swietokrzyskie Voivodship
Autorzy:
Adamus-Bialek, Wioletta
Karwacka, Karolina
Bak, Lukasz
Powiązania:
https://bibliotekanauki.pl/articles/1039467.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
epidemiological analysis
water
bottom sediment
water reservoirs
Opis:
One of the important environmental issues is the quality of surface waters in the world. Poland belongs to countries with a low quality of the inland waters. The sanitary condition of the five water reservoirs of south-east Poland was analyzed. Water and sediment samples were incubated on the selective and/or differential media. High concentrations of many common and pathogenic microbial indicators were shown in those samples. Those reservoirs are used by people, especially during summer. Because of the high epidemiological risk, detailed analysis of all inland waters should be performed routinely.
Źródło:
Acta Biochimica Polonica; 2013, 60, 4; 689-693
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Consumption and Savings of Drinking Water in Selected Objects
Autorzy:
Vaverka, Igor
Jakimiuk, Aleksandra
Trach, Yuliia
Koda, Eugeniusz
Vaverková, Magdalena Daria
Powiązania:
https://bibliotekanauki.pl/articles/1838427.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water saver
water consumption
profitability analysis
water use
kindergarten
Opis:
Water is essential to the proper functioning of kindergartens and schools. Nevertheless, water consumption in public facilities is usually high, often exceeding the average household water consumption. Recently, increasing pressure on this valuable and depletable natural resource has been noticed and, therefore, it is interesting to study the water consumption in kindergartens and the possibilities of water saving. The present work examined 6 kindergarten facilities in Kyjov, Czech Republic, where the equipment has been enhanced with the faucet water saving technology. The work analyzed the impact of the equipment on the reduction of water consumption as a raw material and on the financial and economic profitability. The results were estimated based on the variation of two parameters such as average daily water consumption and demand per person. The experiment showed that installing the savers resulted in water savings ranging from 8% to 18.7% for average daily consumption and from 10.02% to 23.2% for per capita demand.
Źródło:
Journal of Ecological Engineering; 2021, 22, 5; 13-25
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Walizka ekochemika - jej wady i zalety
Kit of the ecochemist - advantages and disadvantages
Autorzy:
Rabajczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/106429.pdf
Data publikacji:
2006
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
dydaktyka
środki dydaktyczne
analiza zanieczyszczeń wód
zestawy odczynników
didactics
didactic means
analysis of water contaminants
set reagents
Opis:
Stosując metody, formy i środki dydaktyczne, trzeba mieć świadomość ich wad i zalet. Dlatego też przeprowadzono ankietę wśród uczestników nieformalnych zajęć terenowego laboratorium biologiczno-chemicznego. Zajęcia te prowadzone były z zastosowaniem różnorodnych metod, form oraz z wykorzystaniem wielu środków dydaktycznych. Do analizy zanieczyszczeń wód, m.in. azotanów(V), fosforanów(V), wykorzystywane były proste i łatwe w obsłudze zestawy odczynników. Na podstawie otrzymanego w wyniku reakcji zabarwienia i natężenia koloru można było określić występowanie analizowanego związku lub jego brak. Uczestnicy zajęć wskazali zarówno na wady, jak i zalety stosowania zestawów. Oceny te, w zależności od grupy wiekowej (klasy gimnazjalne oraz klasy ponadgimnazjalne), kształtowały się w odmienny sposób.
When applying the methods, forms and didactic means their advantages as well as disadvantages should be taken into consideration. Therefore a survey was conducted among the participants of informal classes “Biological-chemical laboratory”. The classes were conducted with the use of various methods as well as many other didactic forms. For the analysis of water contaminants: nitrates and phosphates, sets of easy to operate reagents were used. On the basis of the intensity of the colour received as a result of the reaction, it was possible to determine occurrence of the analysed compound or its lack. The participants of the classes pointed as the disadvantages as well as advantages of using the kits. These opinions, depending on the age (junior secondary schools as well as senior secondary schools) were different.
Źródło:
Chemistry-Didactics-Ecology-Metrology; 2006, 11, 1-2; 55-59
2084-4506
Pojawia się w:
Chemistry-Didactics-Ecology-Metrology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of the heated water discharge on the water quality in a shallow lowland dam reservoir
Autorzy:
Mazierski, Jerzy
Kostecki, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1845417.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
water quality
factor analysis
multivariate statistical analysis
Opis:
The purpose of the work was to determine the relationship between the of the water quality parameters in an artificial reservoir used as cooling ponds. Factor analysis were applied to analyze eighteen physico- -chemical parameters such as air and water temperature, dissolved oxygen concentration, visibility of the Secchi disk, concentrations of total nitrogen, ammonium, nitrate, nitrite, total phosphorus, phosphate, concentrations of calcium, magnesium, chlorides, sulfates and total dissolved salts, pH, chemical oxygen demand and electric conductivity from 2002-2019 to investigated cooling water discharge. Exploratory factor analysis allowed identified four factors were obtained from 54.1% (in discharge zone) to 56.7% (in dam zone). In discharge and pelagic zones confirmatory factor analysis showed that four latent variables: salinity, temperature, nitrogen and phosphorus provide good fit, but in the dam zone the better fit was obtained for the latent variables salinity, temperature, nutrient and eutrophic. Correlations between latent variables temperature, nitrogen, phosphorus or nutrient and eutrophic show a significant effect of temperature on the transformation of nitrogen and phosphorus compounds.
Źródło:
Archives of Environmental Protection; 2021, 47, 2; 29-46
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Principal Component Analysis and Cluster Analysis In Multivariate Assessment of Water Quality
Autorzy:
Jankowska, J.
Radzka, E.
Rymuza, K.
Powiązania:
https://bibliotekanauki.pl/articles/124319.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
principal component analysis
water quality
cluster analysis
Opis:
This paper deals with the use of multivariate methods in drinking water analysis. During a five-year project, from 2008 to 2012, selected chemical parameters in 11 water supply networks of the Siedlce County were studied. Throughout that period drinking water was of satisfactory quality, with only iron and manganese ions exceeding the limits (21 times and 12 times, respectively). In accordance with the results of cluster analysis, all water networks were put into three groups of different water quality. A high concentration of chlorides, sulphates, and manganese and a low concentration of copper and sodium was found in the water of Group 1 supply networks. The water in Group 2 had a high concentration of copper and sodium, and a low concentration of iron and sulphates. The water from Group 3 had a low concentration of chlorides and manganese, but a high concentration of fluorides. Using principal component analysis and cluster analysis, multivariate correlation between the studied parameters was determined, helping to put water supply networks into groups according to similar water quality.
Źródło:
Journal of Ecological Engineering; 2017, 18, 2; 92-96
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atomic forms of selenium in selected mineral and well water in Poland
Formy selenu w mineralnych i pitnych wodach w Polsce
Autorzy:
Gawloska-Kamocka, A.
Powiązania:
https://bibliotekanauki.pl/articles/873337.pdf
Data publikacji:
2009
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
atomic form
selenium
mineral water
drinking water
food analysis
speciation analysis
Polska
Opis:
The study aimed at application of a high performance liquid chromatography (HPLC) with UV detector for selenium speciation in samples of mineral and well waters in Poland. Basic solutions 1000 μg/l SeO3 2- and SeO4 2- were prepared by dissolving 2.190 g of reagent Na2SeO3 and 2.393 g Na2SeO4 in 1000 ml of deionised water, respectively. Recent standards SeO3 2- and SeO4 2- (single or mixed) were prepared daily. Chromatographic separations were obtained on a column with reversed phase of C18, 250*4 mm, 5 μm ODS. As mobile phase mixture of 5 mmol/l phosphate tetrabutylammonium, 50/50 water/methanol at pH 3.4 was used. Flow rate of mobile phase was1 ml/min and detector was set on λ=210 nm. Injection volumes were 5 μl. The average concentration of Se(IV) was 4.10 μg/l and Se(VI) - 4.27 μg/l and Se(II) - 0.54 μg/l although the differences between water samples originating from various sources were relatively high. The developed method can be therefore recommended for determination of Se in samples of mineral water.
Celem pracy było wykorzystanie metody HPLC do badania specjacji selenu w mineralnych i pitnych wodach. Roztwory podstawowe Na2SeO3 i Na2SeO4 o stężeniu 1000 μg/l przygotowano przez rozpuszczenie 2,190 g Na2SeO3 i 2,393 g Na2SeO4 w 1000 ml wody dejonizowanej. Świeże standardy SeO3 2- i SeO4 2- (pojedyncze lub mieszane) były przygotowane codziennie, z roztworów podstawowych. Rozdziały chromatograficzne uzyskano na kolumnie z fazą odwróconą C18, 250*4 mm, 5 μm ODS. Fazą ruchomą była mieszanina 5 mmol/l fosforanu tetrabutyloamoniowego, 50/50 woda/metanol o pH 3,4. Szybkość przepływu fazy ruchomej wynosiła 1ml/min. W badaniach stosowano detekcję przy długości fali λ=210 nm. Objętość badanych próbek wynosiła 5 μl. Wszystkie warunki pomiarów uprzednio zoptymalizowano. Średnia zawartość Se(IV) w badanych wodach wynosiła 4,10 μg/l, a Se(VI) 4,27 μg/l i Se(II) 0,54 μg/l, chociaż obserwowano znaczne różnice w zależności od pochodzenia próbki. Opracowana metoda RP-HPLC-UV może być wykorzystana do badania specjacji selenu w próbkach wody mineralnej.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2009, 60, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of environmetric methods to investigate control factors on water quality
Autorzy:
Boyacioglu, H.
Powiązania:
https://bibliotekanauki.pl/articles/205171.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
water quality
factor analysis
environmetric methods
discriminant analysis
Opis:
In the study, environmetric methods were successfully performed a) to explore natural and anthropogenic controls on reservoir water quality, b) to investigate spatial and temporal differences in quality, and c) to determine quality variables discriminating three reservoirs in Izmir, Turkey. Results showed that overall water quality was mainly governed by “natural factors” in the whole region. A parameter that was the most important in contributing to water quality variation for one reservoir was not important for another. Between summer and winter periods, difference in arsenic concentrations were statistically significant in the Tahtalı, Ürkmez and iron concentrations were in the Balçova reservoirs. Observation of high/low levels in two seasons was explained by different processes as for instance, dilution from runoff at times of high flow seeped through soil and entered the river along with the rainwater run-off and adsorption. Three variables “boron, arsenic and sulphate” discriminated quality among Balçova & Tahtalı, Balçova & Ürkmez and two variables “zinc and arsenic” among the Tahtalı & Ürkmez reservoirs. The results illustrated the usefulness of multivariate statistical techniques to fingerprint pollution sources and investigate temporal/spatial variations in water quality.
Źródło:
Archives of Environmental Protection; 2017, 43, 3; 17-23
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Factors Affecting Water Quality in a Water Supply Network
Autorzy:
Jachimowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/124812.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
factor analysis
secondary contamination of water
water supply network
water quality
Opis:
An effect of factors determining water quality in the water supply network in Kraków is assessed. The data collected over a four-year research period included quality parameters of water taken from the water distribution system in the period between 1 January 2011 and 31 December 2014. In the analysis the supply zones of four municipal water treatment plants in Krakow were considered. The selection of 29 water sampling points within the supply area allowed comparing water quality with respect to operational and technological aspects. Factor analysis enabled 4 components explaining correlations between tap water quality variables to be distinguished. It follows from the research performed that the obtained factors applied to 77% of overall water variability. The highest share was assigned to factor 1 that explained 32% of the chemical composition of water under consideration and was correlated with calcium, conductance, nitrates (V), magnesium and to a moderate extent with Σ THM (with negative sign).
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 110-117
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Addressing Water Scarcity in Samdrupjongkhar Thromde, Bhutan : feasibility Study and Design of a Sustainable Gravity Water Supply System
Autorzy:
Tamang, Phurba
Tenzin, Rigden Yoezer
Tshering, Dawa
Sharma, Vasker
Powiązania:
https://bibliotekanauki.pl/articles/31340454.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
water supply
gravity water flow
EPANET analysis
water pipe system design
Opis:
The provision of a reliable water-supply system is essential for the development and well-being of urban communities. Samdrupjongkhar Thromde, located in Bhutan, has been facing water supply challenges despite the presence of a water treatment plant. The non-perennial nature of the current water source coupled with malfunctions in water pumps has led to acute water shortages in the municipality. To address this issue, this study carried out a feasibility investigation and designed a gravity water supply system by conducting an EPANET (Environment Protection Agency Network Evaluation Tool) analysis. The study involved field visits to identify potential water sources, and a topographic survey using RTK (Real Time Kinematics) technology to determine the optimal pipeline route. The EPANET analysis was then conducted to evaluate the hydraulic performance of the initial route. Based on these findings, a final water pipeline route was selected considering factors such as terrain characteristics, construction feasibility, avoidance of negative water pressure, and minimum encroachment of private land. The results showed that the maximum pressure head within the pipeline system reached 296 m with a maximum water flow velocity of 5 m/s. However, at the outlet, the pressure head decreased to 70 m and the velocity decreased to 2 m/s. Two Break Pressure Tanks (BPT) were strategically placed to achieve this pressure reduction. The chosen pipe materials and their placement ensure the long-term reliability and functionality of the water supply system, while considering maintenance convenience and terrain characteristics.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2023, 70, 1; 101-113
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Formation of a Favorable Filtration Regime of Soils in Saline Areas of the Danube Delta Rice Irrigation Systems
Autorzy:
Turcheniuk, Vasil
Rokochinskiy, Anatoliy
Kuzmych, Lyudmyla
Volk, Pavlo
Prykhodko, Nataliia
Powiązania:
https://bibliotekanauki.pl/articles/31340455.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
water supply
gravity water flow
EPANET analysis
water pipe system design
Opis:
The environmental state of rice irrigation systems (RIS) is determined by many factors, including natural ones (soil, topographical, hydrogeological, and climatic factors) and technological ones (irrigation norm, design, and parameters of irrigation and drainage networks, etc). The most significant influence on the ecological reclamation state of the RIS carries is effected by its drainage network (DN). The need to maintain a flushing water regime with specific filtration rates to prevent secondary salinization in the Danube Delta’s rice systems is a crucial aspect of managing these agricultural areas. In the saline areas of rice systems located in the Danube Delta, the DN must ensure the maintenance of the flushing water regime with the rates of filtration ranging between 10 to 12 mm/day. This is a prerequisite for preventing secondary salinization of irrigated lands of these rice systems. According to the results of studies, the filtration from the surface of the irrigation checks of the Danube Delta RIS has been established, and its values in the area of the rice check vary significantly. Different intensity of filtration in the area of rice checks causes the difference in mineralization of groundwater and in the content of salts in the soil. This leads to the fact that the same rice check created various natural reclamation conditions and different productivity of cultivated crops.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2023, 70, 1; 115-128
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cost analysis of water charge rates in the Czech Republic – Case study
Autorzy:
Oblouková, Aneta
Vítková, Eva
Powiązania:
https://bibliotekanauki.pl/articles/36074702.pdf
Data publikacji:
2024
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
water charge rates
calculation formula
water management companies
region
Czech Republic
vertical analysis
horizontal analysis
Opis:
The article was conceived as an initial insight into the issues related to the representation of individual type costs (e.g. material, labor costs, property depreciation, etc.) in the price of water in the Czech Republic. The aim of the article was to point out the possibility of dependence between the size of the company operating the infrastructural property of water supply and sewerage and the representation of individual costs in the water price within the framework of the case study. As a sample that formed the outputs of the case study, 14 companies were taken, which were selected according to the unified regions of the Czech Republic. Both basic mathematical methods and elementary methods used in financial analysis were used in the analysis. Within the scope of the case study, it can be stated that there is no dependence between the size of the companies and the representation of costs. Among the largest costs from the point of view of financial representation are other direct costs, where the costs of depreciation, property repairs, rental property, as well as wage costs and material costs are mainly represented. Insignificant costs include, for example, energy costs, which are only represented in the range of 1.39–5.70% of the total costs. Therefore, in order for the results included in the case study to be considered statistically relevant, it is necessary to expand the sample and confirm or refute the initial findings published in this article.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2024, 33, 1; 33-52
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinematic analysis of the kick start from OSB12
Autorzy:
Matúš, Ivan
Kandráč, Róbert
Powiązania:
https://bibliotekanauki.pl/articles/1922303.pdf
Data publikacji:
2020-11-18
Wydawca:
PPHU Projack Jacek Wąsik
Tematy:
swimming
water sports
movement analysis
kinematics
Opis:
Introduction: Start performance in swimming plays a major role in determining the final standings, especially in sprint races. The purpose of the study was to determine kinematic parameters underlying the kick start from OSB12 in terms of the kick plate position and shoulder positioning at the start. Material and methods: The sample included 8 non-randomly recruited performance-level swimmers whose average age, body height, and body weight was 17.4 ± 1.8 years, 182.2 ± 3.4 cm and 81.00 ± 3.9 kg, respectively. To measure the kinematic parameters, we used the SwimPro camera system. The parameter rs measured included angular parameters and kinematic parameters for each of the start phases: block phase, flight phase, and water phase. We processed the collected biomechanical data using the Statistica 12.0 software. To determine significant differences between the kick plate positions in three types of start, we applied the Mann-Whitney U test. Results: We found significant differences (p<0.05) in the selected kinematic parameters in all phases, which depended on the OSB12 kick plate position and basic starting position (front-, neutral-, and rear-weighted). The greatest differences in the parameters measured were found between the front-weighted start and rearweighted start. We may conclude that performance-level swimmers should adjust the rear kick plate to positions 3 and 4 and assume the following starting position: front knee angle between 131° and 133°, rear knee angle around 80°, and trunk angle between 40° and 41°. This starting position affects the flight phase, namely takeoff angle (40⁰-41⁰), head position at takeoff (1.33-1.38 m), flight time and distance (0.346-0.368 s; 2.74-2.79 m), entry angle (38⁰). The starting position also affects the glide phase, namely the glide time and distance (0.532-0.536 s; 2.22-2.26 m) and maximum depth (-0.91-0.92 m). Conclusions: The results of the study show that swimmers produced shorter times to 5 meters and higher velocity at 5 meters compared with other starting positions and OSB12 kick plate positions.
Źródło:
Physical Activity Review; 2020, 2, 8; 86-96
2300-5076
Pojawia się w:
Physical Activity Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skład chemiczny wód ze źródeł i z szybów rejonu Ponidzia
Chemical composition of water from springs and wells in the Ponidzie area
Autorzy:
Lipiec, I.
Powiązania:
https://bibliotekanauki.pl/articles/2061958.pdf
Data publikacji:
2015
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
typy chemiczne wód
analiza chemiczna wody
Ponidzie
źródła
springs
chemical type of waters
chemical analysis of water
Ponidzie region
Opis:
Skład chemiczny wód ze źródeł i z szybów występujących na obszarze Ponidzia określono na podstawie wyników badań własnych wykonanych w 2012 r. oraz analiz archiwalnych. Podczas prac terenowych zinwentaryzowano 18 źródeł i 2 szyby i określono skład chemiczny ich wód. Badane wody, według klasyfikacji Altowskiego i Szwieca, należą do typów hydrochemicznych HCO3-Ca-Mg, Ca-HCO3-SO4 i od Na-Cl do Cl-Na. Mineralizacja wód waha się w granicach 0,5–46,8 g/dm3. Występowanie na obszarze badań wód o tak różnym składzie chemicznym jest związane ze skomplikowaną budową geologiczną rejonu Ponidzia (struktura blokowo-fałdowa pocięta licznymi uskokami).
The chemical composition of waters from springs and wells in the Ponidzie area has been established based on research carried out in 2012 and on archived data. During field work, an inventory of 18 springs and two wells was made and the chemical composition of water was determined. The hydrochemical facies of water (according to Altowski and Szwiec classification) are of the following types: HCO3-Ca-Mg, Ca-HCO3-SO4 and from Na-Cl to Cl-Na, with the TDS concentrations in the range of 0.5–46.8 g/dm3. Such variable chemical composition is associated with a complicated geological structure of the Ponidzie area (a block-folded structure cut by numerous faults).
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2015, 462; 153--162
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of risk and failure scenarios in water supply system
Autorzy:
Boryczko, K.
Rak, J.
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/2069508.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
fault tree analysis
matrix methods
risk analysis
water supply system
Opis:
Water supply system is complicated technical system which belongs to underground urban infrastructure. Its accurate functioning determines everyday live stability of citizens. Risk analysis is a key phase of the process of water supply safety management. The aim of this paper is to present new propose of methods for risk of the first type (associated with quantity of supplied water) and the risk of the second type (associated with quality of supplied water) analyses in water supply system. The paper contains the description of matrix methods for risk analyses and methods describing cause-and-effect relationship of failure events (fault tree analysis).
Źródło:
Journal of Polish Safety and Reliability Association; 2014, 5, 2; 11--18
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relationship between water content and grain weight in developing wheat grains.
Autorzy:
Chanda, S. V.
Singh, Y.D.
Powiązania:
https://bibliotekanauki.pl/articles/2198878.pdf
Data publikacji:
2002-06-23
Wydawca:
Instytut Hodowli i Aklimatyzacji Roślin
Tematy:
grain growth analysis
water content
biphasic regression analysis
Triticum aestivum
Opis:
Grains from basal (4th), central (8th) and apical (12th) spikelets of a wheat (Triticum aestivum L.) cultivar Lok-1 were investigated for their fresh weight, dry weight and water content. Each spikelet had 3 grains and so in all 9 grains were analyzed. Grain dry weight data was fitted to polynomial equations and biphasic linear regression analysis. The experiments described here indicated that grains having maximum water content had maximum grain weight and vice versa. Maximum water content and maximum grain weight showed a highly significant linear correlation (P < 0.001). It is suggested that in genetic manipulation in wheat, maximum water content can be a used as a reliable criterion to help in selection for final grain weight.
Źródło:
Plant Breeding and Seed Science; 2002, 46, 1; 55-60
1429-3862
2083-599X
Pojawia się w:
Plant Breeding and Seed Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Shoreline Changes and the Groundwater Quality along the Coast of Kuakata, Patuakhali, Bangladesh
Autorzy:
Goswami, Sukhen
Rahman, Shaikh Ashikur
Alam, Mir Md. Tasnim
Rahman, Mahfuzur
Rafiq, Md. Risalat
Jaman, Md. Hasnat
Roy, Dhiman Kumer
Powiązania:
https://bibliotekanauki.pl/articles/2173235.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
saline water intrusion
hydrogeochemical analysis
digital shoreline analysis system
salinity
Opis:
Shoreline changes and groundwater quality monitoring have become pressing issues for the coastal region of Bangladesh. This study investigated the shoreline changes from 2000 to 2020 and evaluated the groundwater quality, as well as SWI in the Kuakata coastal area. While analyzing satellite images, the temporal shoreline changes were assessed through the Digital Shoreline Analysis System (DSAS) in ArcGIS 10.4.1. Higher erosion rates (>2 m/year) were found in the southernmost part and the SE part of the studied area. Twenty-five groundwater samples were collected, and the physicochemical parameters were measured to assess the groundwater quality. The geographic information system (GIS) was used to assess the spatial variation of the EC, pH, and Cl⁻ contents through the inverse distance weighted (IDW) interpolation method. The EC, Cl⁻, and pH values of the studied groundwater ranged from (1.2 mS/cm to 19.5 mS/cm), (79.88 mg/L to 11241.67 mg/L), and (7.9 to 8.7), repectively. The analysis revealed that the majority of the groundwater samples were unsuitable for drinking purpose due to higher EC and Cl⁻ values. Saline water intrusion (SWI) was determined by using the alternative EC vs Cl⁻ method in the southern part of the Kuakata beach area, which was closest to the sea.
Źródło:
Journal of Ecological Engineering; 2022, 23, 7; 323--332
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiz neuchtennykh raskhodov vody v sisteme vodootvedenija
An analysis of unaccounted water in the sewerage system
Autorzy:
Zajjchenko, L.
Lesnojj, V.
Popov, A.
Powiązania:
https://bibliotekanauki.pl/articles/76820.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
water supply system
sanitation
sewage system
waste water
service
cost
analysis
Opis:
The methods of determining the unaccounted water in the sewerage system has been developed. An objective assessment of these costs will assign economically to justify tariffs for water and wastewater services, to carry out targeted work on resource companies on water supply and sanitation.
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2013, 15, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Failure risk analysis in the water distribution system
Autorzy:
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/2069656.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
risk analysis
failure
risk
water distribution system
Opis:
A water distribution system (WDS) ought to be high reliable continuous operating system. Failure factors in WDS should be identified and prioritised, for example, the causing factors in the most frequent failures in water-pipe network. In this paper, the failure risk analysis of the WDS is presented, and accordingly, a New method consisting the failures index (FI) and the evaluation of risk of failure within the relevant area, based on the assumed categories (tolerable, controlled and unacceptable risk). It is expecting that the methodology for the WDS performance risk analysis would provide the city leadership for decision making support.
Źródło:
Journal of Polish Safety and Reliability Association; 2010, 1, 1; 247--254
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of environmetric & index methods as water quality comparative assessment tools focusing on heavy metal content
Autorzy:
Boyacioglu, H.
Powiązania:
https://bibliotekanauki.pl/articles/204558.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cluster analysis
factor analysis
heavy metal
pollution fingerprint
water quality index
Opis:
In the study suitability of water quality index approach and environmetric methods in fi ngerprinting heavy metal pollution as well as comparison of spatial variability of multiple contaminants in surface water were assessed in the case of The Gediz River Basin, Turkey. Water quality variables were categorized into two classes using factor and cluster analysis. Furthermore, soil contamination index was adapted to water pollution index and used to fi nd out the relative relationship between the reference standards and the current situation of heavy metal contamination in water. Results revealed that surface water heavy metal content was mainly governed by metal processing, textile and tannery industries in the region. On the other hand, metal processing industry discharges mainly degraded quality of water in Kemalpasa and Menemen. Furthermore, Kemalpasa region has been heavily affected from tannery and textile industries effl uents. Moreover, pollution parameters have not been infl uenced by changes in physical factors (discharge and temperature). This study indicated the effectiveness of water quality index approach and statistical tools in fi ngerprinting of pollution and comparative assessment of water quality. Both methods can assist decision makers to determine priorities in management practices.
Źródło:
Archives of Environmental Protection; 2012, 38, 3; 17-28
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Multivariate Statistical Methods to the Hydrochemical Study of Groundwater Quality in the Sahel Watershed, Algeria
Autorzy:
Hakim, Djafer Khodja
Amina, Aichour
Amina, Rezig
Djouhra, Baloul
Ahmed, Ferhati
Powiązania:
https://bibliotekanauki.pl/articles/2173331.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hydrochemical analysis
water quality
groundwater
principal component analysis
hierarchical cluster analysis
Sahel watershed
Opis:
The quality of groundwater is characterized by several numbers of physical and chemical parameters, which determine the use of water (water supply, irrigation, industry). This search paper is a contribution made to know the hydrochemical characteristics of groundwater in the Sahel sub-catchment which belongs to the large Soummam North basin of Algeria. Different multivariate statistical techniques were used such as principal component analysis (PCA), Hierarchical Cluster Analysis (HCA) and Diagram Analysis. These analyses are exercised to a dataset formed from 37 boreholes with 12 chemical variables over the entire surface of the watershed. The samples were collected in 2016. The 37 boreholes are one of the main water resources that supply the wilaya of Bouira with drinking water and irrigation. The analysis of water quality using different methods (ACP, HCA and Diagram) resulted in two chemical kinds: (Chloride, calcium sulfate and magnesium), and (Bicarbonate calcium and magnesium). The results have shown that 74% of the boreholes were contaminated, the rest of boreholes were characterized by a good quality and they have not suffered any contamination and can be consumed without any risk.
Źródło:
Journal of Ecological Engineering; 2022, 23, 8; 341--349
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of water treatment plants quality in Basrah Province, by factor and cluster analysis
Autorzy:
Al Saad, Zainb A.A.
Hamdan, Ahmed N.A.
Powiązania:
https://bibliotekanauki.pl/articles/293213.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
cluster analysis (CA)
factor analysis (FA)
multivariate statistics
the Shatt Al Arab River
water quality
water treatment plant
Opis:
The Shatt Al Arab River (SAAR) is a major source of raw water for most water treatment plants (WTP’s) located along with it in Basrah province. This study aims to determine the effects of different variables on water quality of the SAAR, using multivariate statistical analysis. Seventeen variables were measured in nine WTP’s during 2017, these sites are Al Hussain (1), Awaissan (2), Al Abass (3), Al Garma (4), Mhaigran (5), Al Asmaee (6), Al Jubaila (7), Al Baradia (8), Al Lebani (9). The dataset is treated using principal component analysis (PCA) / factor analysis (FA), cluster analysis (CA) to the most important factors affecting water quality, sources of contamination and the suitability of water for drinking and irrigation. Three factors are responsible for the data structure representing 88.86% of the total variance in the dataset. CA shows three different groups of similarity between the sampling stations, in which station 5 (Mhaigran) is more contaminated than others, while station 3 (Al Abass) and 6 (Al Asmaee) are less contaminated. Electrical conductivity (EC) and sodium adsorption ratio (SAR) are plotted on Richard diagram. It is shown that the samples of water of Mhaigran are located in the class of C4-S3 of very high salinity and sodium, water samples of Al Abass station, are located in the class of C3-S1 of high salinity and low sodium, and others are located in the class of C4-S2 of high salinity and medium sodium. Generally, the results of most water quality parameters reveal that SAAR is not within the permissible levels of drinking and irrigation.
Źródło:
Journal of Water and Land Development; 2020, 46; 10-19
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods for integrated Failure Risk Analysis of Water Network in terms of Water Supply System Functioning Management
Autorzy:
Tchórzewska-Cieślak, B.
Pietrucha-Urbanik, K.
Powiązania:
https://bibliotekanauki.pl/articles/2068882.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
water supply system
failure indicators
risk analysis
Opis:
In the paper the issues connected with failure risk analysis related to the functioning of this system were presented. In the analysis of water supply system it is important to assess the safety of its operation, both from the producer and the consumer point of view. The paper presents the method of analysis of consumers acceptance of water costs that companies bear for the risk reduction. The proposed method can be the basis of comprehensive program of risk failure management and in decision-making on water supply operation.
Źródło:
Journal of Polish Safety and Reliability Association; 2017, 8, 1; 157--166
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki kształtujące jakość wody przed procesem jej uzdatniania
Factors affecting water quality before treatment
Autorzy:
Jachimowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/400608.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
analiza czynnikowa
woda powierzchniowa
jakość wody
factor analysis
surface water
water quality
Opis:
W artykule dokonano oceny wpływu czynników naturalnych i antropogenicznych na jakość wody powierzchniowej ujmowanej przez krakowskie zakłady uzdatniania wody. Analizie poddano wybrane wskaźniki fizykochemiczne w oznaczone w wodzie surowej w latach 2007–2014. Z przeprowadzonych badań wynika, że wody przed procesem uzdatniania różniły się liczbą i udziałem wydzielonych czynników. Składowe te, z kolei wyjaśniały od 63% do 71% składu chemicznego analizowanych wód.
The article assesses the impact of natural and anthropogenic factors on the quality of surface water grasped by Krakow’s water treatment plants. We analyzed the indicators chosen in the physicochemical marked in the raw water in the years 2007–2014. The study shows that the water prior to treatment differed in the number and share of separate factors. These components, in turn, explained 63% to 71% of analyzed chemical composition of water.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 1; 118-125
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Multivariate Technique to Develop Hybrid Water Quality Index of the Bengawan Solo River, Indonesia
Autorzy:
Lusiana, Evellin Dewi
Mahmudi, Mohammad
Hutahaean, Sarah Mega
Darmawan, Arief
Buwono, Nanik Retno
Arsad, Sulastri
Musa, Muhammad
Powiązania:
https://bibliotekanauki.pl/articles/2026733.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
principal component analysis
WQI
water quality index
variable selection
water quality assessment
Opis:
Surface water resource, such as river, is constantly contaminated by domestic and industrial pollutants. In order to properly manage the water resource, a composite index for water quality assessment, such as water quality index (WQI), has been designed to monitor and evaluate the properties of surface water. However, this index is quite subjective in terms of determination of relative weights. A principal component analysis (PCA) can be used to reduce the dimension and subjectivity of water quality variables. The purpose of this study was to implement the use of hybrid PCA and WQI methods to assess and monitor the water quality of the Bengawan Solo River, which is located in Java Island, Indonesia. The result suggested that COD, BOD, TSS, TDS, nitrate, nitrite, and ammonia were the main factors that determine water quality of the Bengawan Solo River. Furthermore, it was revealed that most samples from the river showed water quality status as slightly polluted. In addition to this, the seasonal variation of the PCWI values indicated a significant increase of water pollution in the Bengawan Solo River per year.
Źródło:
Journal of Ecological Engineering; 2022, 23, 2; 123-131
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Climate analysis as a basis for a sustainable water management at the Lusatian Neisse
Autorzy:
Pluntke, T.
Schwarzak, S.
Kuhn, K.
Lünich, K.
Adynkiewicz-Piragas, M.
Otop, I.
Miszuk, B.
Powiązania:
https://bibliotekanauki.pl/articles/108580.pdf
Data publikacji:
2016
Wydawca:
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy
Tematy:
climate analysis
water availability
climate projections
trend analysis
Polish-Saxon border region
Opis:
Current and future climate conditions and their impact on water balance, ecosystems, air quality and bio and agro-climatology were investigated in the region of the Lusatian Neisse within the two EU -projects – NEYMO and KLAPS. This work focuses on the climate analysis of the region at the German-Polish border as a preliminary step for a hydrological analysis of current and future conditions. Observed climatological data were processed and analysed using the indicators air temperature, precipitation, sunshine duration, potential evapotranspiration and the climatic water balance (CWB). The latter defines the difference between precipitation and potential evapotranspiration and is a measure for the climatological water availability in the region. Observations were used to statistically downscale data from Global Circulation Models under various scenarios regarding greenhouse gas emissions (A1B, RCP 2.6, RCP 8.5) and applying the WETTREG-method for regionalization. In total, 50 climate projections for periods up until the end of the 21st century were analysed, with the application of the mentioned indicators. For the period 1971-2010, increasing trends of temperature, precipitation, sunshine duration and potential evapotranspiration were found. This leads to a reduced CWB in the summer half-year (SHY), which could be partly compensated by an increase in the winter half-year (WHY). Trends of temperature, sunshine duration and potential evapotranspiration remain positive for the far future (2071-2100), but precipitation decreases. These climatic conditions aggravate water availability, especially in the SHY. Impacts on water management are very probable and were therefore further investigated in the NEY MO project that applied hydrological models.
Źródło:
Meteorology Hydrology and Water Management. Research and Operational Applications; 2016, 4, 1; 3-11
2299-3835
2353-5652
Pojawia się w:
Meteorology Hydrology and Water Management. Research and Operational Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using chemometrics to identify water quality in Daya Bay, China
Autorzy:
Wu, M.-L.
Wang, Y.-S.
Sun, C.-C.
Wang, H.
Lou, Z.-P.
Dong, J.-D.
Powiązania:
https://bibliotekanauki.pl/articles/49096.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
robust principal component analysis
water quality
chemometrics
China
cluster analysis
Daya Bay
Opis:
In this paper, chemometric approaches based on cluster analysis, classical and robust principal component analysis were employed to identify water quality in Daya Bay (DYB), China. The results show that these approaches divided water quality in DYB into two groups: stations S3, S8, S10 and S11 belong to cluster A, which lie in Dapeng Cove, Aotou Harbor and the north-eastern part of DYB, where water quality is related mainly to anthropogenic activities. The other stations belong to cluster B, which lie in the southern, central and eastern parts of DYB, where the quality is related mainly to water exchange with the South China Sea. Cluster analysis yields good results as a first exploratory method for evaluating spatial difference, but it fails to demonstrate the relationship between variables and environmental quality on the one hand and the untreated data on the other. However, with the aid of suitable chemometric approaches, the relationship between samples or variables can be investigated. Classical and robust principal component analysis can provide a visual aid for identifying the water environment in DYB, and then extracting specific information about relationships between variables and spatial variation trends in water quality.
Źródło:
Oceanologia; 2009, 51, 2; 217-232
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies