Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Inverter" wg kryterium: Temat


Tytuł:
Three-phase soft-switching inverter with coupled inductors, experimental results
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/200045.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant inverter
ZVS inverter
Opis:
This paper presents experimental results of the three-phase soft-switching inverter with coupled inductors that verify the control method influence on efficiency improvement. Different kinds of control methods were tested on the 6 kW experimental inverter. A short discussion on a few design methods of the resonant tank elements was made. Experimental results confirm that the advanced control algorithm and the proposed new design method of the resonant tank elements significantly increase the efficiency of this resonant inverter.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 535-540
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extended T-type inverter
Autorzy:
Rąbkowski, J.
Kopacz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1193496.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
T-type inverter
boost converter
silicon carbide
Opis:
This paper presents a new concept for a power electronic converter – the extended T-type (eT) inverter, which is a combination of a three-phase inverter and a three-level direct current (dc)/dc converter. The novel converter shows better performance than a comparable system composed of two converters: a T-type inverter and a boost converter. At first, the three-level dc/dc converter is able to boost the input voltage but also affects the neutral point potential. The operation principles of the eT inverter are explained and a simulation study of the SiC-based 6 kVA system is presented in this paper. Presented results show a serious reduction of the DC-link capacitors and the input inductor. Furthermore, suitable SiC power semiconductor devices are selected and power losses are estimated using Saber software in reference to a comparative T-type inverter. According to the simulations, the 50 kHz/6 kVA inverter feed from the low voltage (250 V) shows <2.5% of power losses in the suggested SiC metal oxide–semiconductor field-effect transistors (MOSFETs) and Schottky diodes. Finally, a 6 kVA laboratory model was designed, built and tested. Conducted measurements show that despite low capacitance (2 × 30 μF/450 V), the neutral point potential is balanced, and the observed efficiency of the inverter is around 96%.
Źródło:
Power Electronics and Drives; 2018, 3, 38; 55-64
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie falowników rezonansowych w przemyśle elektromaszynowym i wydobywczym
Application of resonance inverters in the electric machine and mining industry
Autorzy:
Marek, A.
Powiązania:
https://bibliotekanauki.pl/articles/186005.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
falownik L-LC
falownik rezonansowy
inverter L-LC
resonance inverter
Opis:
Celem artykułu jest przedstawienie i omówienie najczęściej stosowanych układów zasilających nagrzewnice indukcyjne, ich właściwości oraz porównanie ich z proponowanym rozwiązaniem w postaci falownika L-LC.
The paper aims at a presentation and a discussion on the mostly used power supply systems for induction heaters, their characteristics and comparison to a suggested system in the form of an inverter L-LC.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2009, R. 47, nr 2, 2; 17-22
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental results of parallel connected inverters feeding medium voltage transformer
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/377860.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical transformer
line side inverter
inrush currents
inverter parallel operation
Opis:
Development of medium voltage, high power ship electrical installations on board of special purpose vessels, has led to use of grid side inverters along with step-up grid transformers. In this paper there is presented theoretical background and experimental results of two inverters in parallel connection feeding one 0,4/15 kV transformer.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 359-368
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja wydajności urządzeń potrzeb własnych elektrowni cieplnych asynchronicznymi napędami falownikowymi średniego napięcia
Variable speed drives with frequency converters in thermal power plant auxiliaries
Autorzy:
Wawszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/173004.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia cieplna
napęd falownikowy
przemiennik
thermal power station
inverter drive
inverter
Opis:
Omówiono możliwości regulacji wydajności urządzeń potrzeb własnych elektrowni cieplnych napędzanych klatkowymi silnikami indukcyjnymi zasilanymi przemiennikami częstotliwości. Skupiono się głównie na napędach średnionapięciowych (6÷10 kV) dużej mocy. Przedstawiono aktualną ofertę przemienników czołowych światowych producentów. Oceniono możliwości wykorzystania tego typu napędów w dużych, nowoczesnych elektrowniach blokowych.
The paper introduces current potential of variable speed drives (VSD) intended for squirrel cage induction motors supplied by frequency converters in thermal power plant auxiliaries. The paper is mostly focused on medium-voltage (6-10 kV) and high-power drives. Current tender of leading world producers in this field has been presented. Possibility to apply this type of drives in large, modern block-power plants has been considered.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 87-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adjusting output impedance using a PI controller to improve the stability of a single-phase inverter under weak grid
Autorzy:
Jiao, J.
Nelms, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/136224.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
grid impedance
inverter output impedance
LC filter
PI controller
single-phase inverter
Opis:
Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 50-57
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Z-source converter in photovoltaic grid-connected transformer-less inverter
Autorzy:
Farhangi, B.
Farhangi, S.
Powiązania:
https://bibliotekanauki.pl/articles/262715.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
photovoltaic power conditioner (PV PCU)
gird-connected systems
Z-source inverter
inverter
Opis:
In PV grid connected power conditioners, usually both stepping-up the PV array voltage, and stepping-down the dc bus voltage for injection of a sinusoidal current to the grid is required. In this paper the design procedure of Z-source converter as a single phase PV grid connected transformer-less inverter is presented. The converter has one switch less than the conventional two stage power conditioner, which leads to reduction of cost. An optimum modulation pattern for the switches is proposed, and the low frequency ripple of the converter is modeled. The design of the converter is verified by simulation.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 41-45
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single-source three-phase switched-capacitor-based MLI
Autorzy:
Jena, Kasinath
Gupta, Krishna Kumar
Bhatnagar, Pallavee
Jain, Sanjay K.
Stala, Robert
Waradzyn, Zbigniew
Piróg, Stanisław
Penczek, Adam
Mondzik, Andrzej
Skała, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/2175942.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
switched capacitor
multicarrier pulse width modulation
cost function
ANPC inverter
Opis:
This article proposes a novel three-phase inverter based on the concept of switched capacitors (SCs), which uses a single DC source. A three-phase, seven-level line-to-line output voltage waveform is synthesised by the proposed topology, which includes eight switches, two capacitors, and one diode per phase leg. The proposed topology offers advantages in terms of inherent voltage gain, lower voltage stresses on power switches, and a reduced number of switching components. Additionally, the switched capacitors are self-balanced, thereby eliminating the need for a separate balancing circuit. The proposed structure and its operating principle, the self-balancing mechanism of the capacitors, and the control strategy are all thoroughly explained in the article. The proposed topology has also been compared with some recent SC topologies. Lastly, the proposed topology has been shown to be feasible through simulation and experimentation.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 197--209
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GaN-based soft-switched active power buffer operating at ZCS – problems of start-up and shut-down
Autorzy:
Rąbkowski, J.
Król, K.
Zdanowski, M.
Sochacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/201868.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
GaN
power inverter
active buffer
Opis:
This paper describes practical issues related to control of the active power buffer (APB) developed for a 2 kVA single-phase inverter. The buffer is designed using the latest GaN HEMTs controlled with triangular current mode to reduce switching losses, however, the switching frequency should be limited to 1 MHz. In the case of the presented analogue-digital controller, frequency is influenced by a reference current of the APB and circuit. Therefore, the operation at start-up and shut-down is especially challenging. A modified control algorithm that also includes pre-charging and discharging process of the energy buffer is presented and experimentally verified by series of tests of the 2 kVA GaN based inverter with the APB.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 785-792
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault Diagnosis of Sensors for T-type Three-Level Inverter-fed Dual Three-Phase Permanent Magnet Synchronous Motor Drives
Autorzy:
Wang, Xueqing
Wang, Zheng
Wang, Wei
Cheng, Ming
Powiązania:
https://bibliotekanauki.pl/articles/1193713.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fault diagnosis
sensor fault
T-type inverter
three-level inverter
dual
three-phase
PMSM
Opis:
To improve the reliability of motor system, this paper investigates the sensor fault diagnosis methods for T-type inverter-fed dual three-phase permanent magnet synchronous motor (PMSM) drives. Generally, a T-type three-level inverter-fed dual three-phase motor drive utilizes four phase-current sensors, two direct current (DC)-link voltage sensors and one speed sensor. A series of diagnostic methods have been comprehensively proposed for the three types of sensor faults. Both the sudden error change and gradual error change of sensor faults are considered. Firstly, the diagnosis of speed sensor fault was achieved by monitoring the error between the rotating speed of stator flux and the value from speed sensor. Secondly, the large high-frequency voltage ripple of voltage difference between the estimated voltage and the reference voltage was used to identify the voltage sensor faults, and the faulty voltage sensor was determined according to the deviation of voltage difference. Thirdly, the abnormal current amplitude on harmonic subspace was adopted to identify the current sensor faults, and the faulty current sensor was located by distinguishing the current trajectory on harmonic subspace. The experiments have been taken on a laboratory prototype to verify the effectiveness of the proposed fault diagnosis schemes.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 165-176
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiphase Z-source inverter using maximum constant boost control
Autorzy:
Kouzou, A.
Abu-Rub, H.
Powiązania:
https://bibliotekanauki.pl/articles/229291.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Z-source inverter
multiphase inverter
five phase machine
shoot-through
boost factor
duty cycle
Opis:
This paper deals with the impedance source (Z-source) multiphase inverter, where the maximum constant boost control method is studied and analyzed in the general case of number of phases. On the other side the impact of the modulation index and the number of phases on the duty cycle shoot-through and on the gain of the output voltage ranges is presented. To validate advantages of the Z-source multiphase inverter, the proposed topology and the maximum constant boost control are implemented in simulation and in real time experimentation with Z-source five phase inverter. The output voltage is applied to two parallel loads, a five phase resistive load and a five phase induction machine.
Źródło:
Archives of Control Sciences; 2013, 23, 1; 107-126
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency control of inverter fed induction motor drives
Autorzy:
Shaban, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/376136.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
induction motor
torque-speed characteristic
inverter
Opis:
Induction motor losses at partial loads can be significantly reduced by operating an adjustable frequency drive at the optimum slip which yields maximum efficiency. The present investigation quantifies the potential improvement in induction motor efficiency for both standard and energy efficient motors operating on a six-step voltage-source inverter supply. The analysis employs a comprehensive model of the induction motor which incorporates the frequency - dependent nature of the motor parameters and effects of stray load loss. Efficiency contours are plotted on a torque- speed plane for constant volts/hertz operation and for optimum slip frequency control plotted as a contour map.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 72; 291-295
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified Topology and Modulation Technique for Z-Source Neutral-Point Clamped Inverter
Autorzy:
Akbari, Ehsan
Zishan, Farhad
Powiązania:
https://bibliotekanauki.pl/articles/2175930.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
modulation
optimization
multilevel inverter
MZS-NPC
Opis:
The impedance network makes it possible to increase and decrease the voltage, which is not available in normal inverters (voltage and current sources).This paper presents a modified topology and modulation technique for a three-phase Modified Z-Source Neutral-Point Clamped (MZS-NPC) inverter. A modulation scheme for the proposed topology is designed based on maximum gain control method to achieve the maximum voltage gain by simple implementation and balancing the neutral point voltage of the dc link. In order to supply the desired voltage to the critical load in an islanded micro-grid, a closed-loop ac voltage controller is realized in fuel cell or photovoltaic applications based on the proposed inverter. The ability to reinforce and validity of topology operations and modulation techniques has been demonstrated by simulation. It should be noted that the simulations are implemented in MATLAB / Simulink software.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 210--226
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
Autorzy:
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201199.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronous machine
DC/AC inverter
DTC
flux and torque control
3-level DC/AC inverter
Opis:
This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 771-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odzyskiwanie energii elektrycznej w aplikacjach napędowych z falownikami Danfoss Drives
Autorzy:
Ptaszyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/304909.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
falownik
energia elektryczna
hamowanie
inverter
electricity
braking
Opis:
W artykule przygotowanym przez firmę Schulz Infoprod, która od wielu lat jako Autoryzowany Dystrybutor współpracuje z Danfoss, przedstawiono rozwiązania kontroli energii oddawanej przez napęd w trakcie dynamicznego hamowania.
Źródło:
Napędy i Sterowanie; 2017, 19, 3; 28-30
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamiczna regulacja mocą przekształtników sieciowych
Dynamic power control of the grid converters
Autorzy:
Zieliński, D.
Powiązania:
https://bibliotekanauki.pl/articles/407678.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
przekształtnik
VOC
LVRT
Simulink
inverter
PI algorithm
Opis:
Dynamicznie rozwijający się sektor źródeł odnawialnych zmusza urząd regulacji energetycznej do wprowadzania coraz bardziej rygorystycznych norm odnośnie jakości dostarczanej energii i dynamiki samych źródeł. W przyszłości przepisy będą wymagały by źródło energii odnawialnej własnościami dynamicznymi przypominało generator synchroniczny o równoważnej mocy. Ponadto źródło powinno własności tłumienia oscylacji mocy w systemie elektroenergetycznym i powinno wspomagać sieć w odbudowie napięcia. Powyższe przyczyny implikują sterowanie nieliniowe wysokiej dynamiki układów pośredniczących pomiędzy źródłem a siecią jakim są przekształtniki. Artykuł prezentuje regulator nieliniowy poprawiający dynamikę sterowania mocą w układach przekształtników wektorowych. Analizę dokonano za pomocą oprogramowania Matlab/SIMULINK.
The dynamic growth of the renewable energy sources sector causes that the Energy Regulatory Office introduces stricter and stricter grid codes about quality of the energy and dynamics of the sources. In the future, grid codes will require that the dynamic properties of the renewable source of energy is similar to the synchronous generator with the same power. Moreover, the renewable source of energy should damp power oscillation in power grid, and support it to stabilize the voltage. These causes lead us to use a high dynamic nonlinear control system – converters, installed between a source and a power grid. The paper presents a nonlinear controller improves the dynamic power control of the vector inverters’ systems. The analysis was made by using the MATLAB/Simulink software.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 1; 59-62
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of harmonic voltage coupling on torque ripple of permanent magnet synchronous motor
Autorzy:
Geng, Shengtao
Zhang, Yong
Qiu, Hongbo
Yang, Cunxiang
Yi, Ran
Powiązania:
https://bibliotekanauki.pl/articles/140572.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PMSM
harmonic voltage coupling
torque ripple
inverter
Opis:
The permanent magnet synchronous motor (PMSM) driven by an inverter is widely used in the industrial field, but the inverter has a significant impact on the operational stability of the PMSM. The torque ripple of the PMSM is directly affected by the coupling of multiple harmonic voltages in the motor windings. In order to analyze its influence, a water-cooled PMSM with 20 kW 2000 r/min is taken as an example to establish the finite element model of the prototype, and the correctness of the model is verified by experiments. Firstly, based on the finite element method, the electromagnetic field of the PMSM is numerically solved in different operating states, and the performance parameters of the PMSM are obtained. Based on these parameters, the influence of the harmonic voltage amplitude on the torque ripple is studied, and the influence law is obtained. Secondly, combined with the decoupling analysis method, the influence of harmonic voltage coupling on the torque ripple is compared and analyzed, and the variation law of harmonic voltage coupling on the torque ripple is obtained. In addition, the influence of different harmonic voltage coupling on the average torque of the PMSM is studied, and the influence degree of different harmonic voltage amplitude on the torque fluctuation is determined. The conclusion of this paper provides reliable theoretical guidance for improving motor performance.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 399-410
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel in-phase disposition SPWM pulse allocation strategy for cascaded H-bridge inverter
Autorzy:
Zhang, Y.
Xiong, J.
Kong, L.
Wang, X.
Powiązania:
https://bibliotekanauki.pl/articles/141155.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
in-phase disposition SPWM
Inverter
CHB
THD
Opis:
A novel in-phase disposition (IPD) SPWM pulse allocation strategy applied to a cascaded H-bridge (CHB) converter is presented in this paper. The reason causing the power of the CHB converter imbalance is analyzed according to the traditional structure, the conception of power imbalance degree is introduced and the principle of the novel in-phase disposition SPWM allocation strategy is deduced in detail. The new pulse allocation scheme can ensure the power balance in 3/4 cycles through interchanging the PWM pulse sequence of the different CHB cell, meanwhile it makes the full advantage of the IPD control strategy, lower the total harmonic distortion (THD) of line voltage compared to a carrier phase shifted (CPS) control strategy, which is verified by theoretical derivation. A seven-level cascaded inverter composed by three H-bridge cells is taken as the example. The simulation and experiment is performed. The results indicate the validity of the analysis and verify the effectiveness of the proposed SPWM allocation strategy.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 361--375
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of 5 kW Converter Leg for Power Electronic System
Autorzy:
Zygmanowski, M.
Michalak, J.
Jeleń, M.
Jarek, G.
Powiązania:
https://bibliotekanauki.pl/articles/973060.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IGBT
Silicon Carbide (SiC)
MOSFET
Inverter
Microgrid
Opis:
Three converter leg variants are analyzed for low power converter used for power electronic system for residential buildings. The two-level Si-IGBT and SiC-MOSFET converters are compared with Si-IGBT three-level T-type converter. Power losses generated in each of these converters over a predicted period of 20 years of operation are contrasted with the cost of converter options. The detailed selection procedure for output inductor is presented in this paper. This procedure shows the influence of the inductor parameters like number of turns, air gap length on its losses, cost and size. Theoretical approach is verified with simulations and experimental results.
Źródło:
Measurement Automation Monitoring; 2017, 63, 8; 282-287
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Passive filter design for three-phase inverter interfacing in distributed generation
Autorzy:
Ahmed, K. H.
Finney, S. J.
Williams, B. W.
Powiązania:
https://bibliotekanauki.pl/articles/262578.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
DG
inverter
grid connected
filtering
damping
harmonics
Opis:
With the growing use of inverters in distributed generation, the problem of injected harmonics becomes critical. These harmonics require the connection of low pass filters between the inverter and the network. This paper presents a design method for the output LC filter in grid coupled applications in distributed generation systems. The design is according to the harmonics standards that determine the level of current harmonics injected into the grid network. Analytical expressions for the maximum inductor ripple current are derived. The filter capacitor design depends on the allowable level of switching components injected into the grid. Different passive filter damping techniques to suppress resonance affects are investigated and evaluated. Simulated results are included to verify the derived expressions.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 49-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-level modulation techniques to reduce instantaneous common mode voltage in induction machines
Autorzy:
Cusidó, J.
Luna, A.
Busquets, S.
Bordonau, J.
Rodríguez, P.
Romeral, L.
Powiązania:
https://bibliotekanauki.pl/articles/262817.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
common mode voltages
multilevel inverter
drive systems
Opis:
Problems on inverter motor drives such as bearing currents are introduced due to common mode voltages. Different solutions are proposed on literature, for two-level or multilevel inverter. Instantaneous zero common mode voltage by using a three-level inverted could be achieved. This paper proposes a commutation strategy that allows zero common mode voltage by using medium vectors, and also a new representation as a plane on the commutation space is defined which is called zero common mode voltage plane. On this defined plane, every turning vector fulfil this property. Simulations and experimental results clearly show method's efficiency.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 33-38
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PQ Cootrol of Photovoltaic Power Statioo in Microgrid Operation
Autorzy:
Cygan, S.
Łukowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/410543.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
inverter PQ control
PowerSys microgrid model
microgird control
Opis:
The numerical modelling of the photovoltaic module and the solar inverter interconnected with the microgrid has been carried out with the use of PowerSys in Matlab/Simulink. Algorithms of P, Q controllers have been proposed. The capability of the active and reactive power reference tracking has been tested for various conditions.
Źródło:
Present Problems of Power System Control; 2017, 8; 51-59
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical method of a calculation of a torque ripple of a two-phase asynchronous motor supplied by a pwm controlled inverter
Metoda analityczna obliczania pulsacji momentu dwufazowego silnika asynchronicznego zasilanego z falownika PWM
Autorzy:
Záskalický, P.
Powiązania:
https://bibliotekanauki.pl/articles/1368690.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
asynchronous motor
PWM controlled inverter
modeling
analytical method
Opis:
The paper deals with steady state calculation of torque and currents ripples of a two-phase asynchronous machine, which is supplied by an IGBT transistors half-bridge connected inverter. The inwerter output voltage is controlled by a PWM of the input DC voltage. The complex Fourier series analysis of the inverter output voltage was made, to obtain a spectrum of the harmonic supply voltages. The different voltage harmonic was applied to the two-phase induction machine model to obtain the electromagnetic torque and currents waveforms for various operation conditions.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 131-135
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
Autorzy:
Turzyński, M.
Banach, P.
Murawski, P.
Pepliński, R.
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200484.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resonant converters
ZVS three-phase inverter
current estimation
Opis:
Control of parallel quasi resonant dc link inverters (PQRDCLI) is usually based on dc link input inverter current. Instead of a direct measurement of this noise sensitive and fast changing current signal - its estimation with one step prediction may be considered. Estimation of an input inverter current is based on inverter output current measurements, applied in most of power electronics controlled ac drives. In this paper, the PQRDCLI fed induction motor (IM) with a predictive current estimation stabilizes resonant inverter output voltage slopes du/dt independently of load. By control of output voltage derivatives, reduction of overvoltage spikes and common mode motor currents is achieved. An analysis of the PQRDCLI control with a predictive current estimation strategy is verified by the Saber system simulation and experimental tests in a laboratory setup.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 757-762
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Falowniki trakcyjne kolejowych pojazdów szynowych – rozwiązania techniczne i kierunki rozwoju konstrukcji
Static converters of railway vehicles - technical solutions and directions of construction development
Autorzy:
Biliński, Janusz
Malczewska, Marta
Rojek, Artur
Kruczek, Włodzimierz
Powiązania:
https://bibliotekanauki.pl/articles/253989.pdf
Data publikacji:
2020
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
pojazdy kolejowe
falownik trakcyjny
railway vehicles
traction inverter
Opis:
Nowoczesna technologia i ciągły rozwój na rynku komponentów elektronicznych pozwala na tworzenie bardziej energooszczędnych, lżejszych, cichszych i mniejszych systemów trakcyjnych [1]. W artykule przedstawione zostały różne systemy trakcyjne wraz z ich parametrami zależnymi od architektury pojazdu. Architektura pojazdu ściśle wiąże się z napięciem sieci trakcyjnej oraz typem przejazdów realizowanych przez te pojazdy (miejskie, regionalne, szybkie, towarowe) [2].
Innovative technology and continuous development of the electronic components industry enables creation of components of higher energy-efficiency, lighter, quieter and even smaller traction systems [1]. The article presents different traction systems with their parameters which are highly depend on the vehicle architecture. The vehicle architecture is strongly related to the catenary line voltage and type of service provided by vehicles (urban, regional, fast, cargo) [2].
Źródło:
TTS Technika Transportu Szynowego; 2020, 5-6; 43-57
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalne sterowanie falownika przy jego pracy na sieć systemu energetycznego
Optimal inverter controling during its operation for power grid
Autorzy:
Mazur, D.
Powiązania:
https://bibliotekanauki.pl/articles/1369606.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
optymalne sterowanie
system energetyczny
optimal inverter
power grid
Opis:
The inverter circuit is supposed to operate for grid with low internal impedance (for fixed grid). The goal of the presented circuit is to provide the given current of the main harmonic to the grid. The grid can contain higher harmonics of the voltage, which due to the low impedance of the grid lines spreads to the voltage of the inverter output. Therefore we need to calculate the first (main) harmonic of this voltage and find such inverter controlling, that the main harmonic of the current flowing to the grid from the considered circuit would be in the given angle position to it and at the given value. The second important goal of the circuit is, as far as possible, to eliminate the voltage higher harmonics at the circuit output getting there from the grid. Obviously eliminating the ripples from voltage higher harmonics of the receiver is limited by the capabilities of the examined inverter circuit.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 2, 95; 25-30
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona układu izolacyjnego transformatora współpracującego z falownikami
Protection of the transformer insulation system cooperating with inverters
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2142529.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
falownik
kondensator
warystor
transformer
inverter
capacitor
varistor
Opis:
Farmy fotowoltaiczne są łączone z siecią elektroenergetyczną poprzez falownik DC/AC i transformator. Komutacja prądu w zaworach falownika generuje w indukcyjnościach rozproszenia impulsy napięcia, które oddziałują na układ izolacyjny uzwojeń transformatora. Skuteczną ochronę izolacji uzwojeń transformatora przed przepięcia stanowią filtry tłumiące. Mogą to być kondensatory bądź warystory. Filtr w sposób znaczący poprawia warunki dielektryczne izolacji uzwojenia transformatora.
The solar farms are connected to the electricity grid through a DC / AC inverter and a transformer. The current commutation in the inverter valves generates voltage pulses in the leakage inductances, which act on the insulation system of the transformer windings. Suppression filters provide effective protection of the transformer winding insulation against overvoltage. These can be capacitors or varistors. The filter significantly improves the dielectric conditions of the transformer winding insulation.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 41--44
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ przemienników częstotliwości na pracę silników indukcyjnych w podziemiach kopalń
Influence of frequency innverters on operation of induction motors in mine environment
Autorzy:
Marek, A.
Powiązania:
https://bibliotekanauki.pl/articles/113133.pdf
Data publikacji:
2017
Wydawca:
STE GROUP
Tematy:
pośredni przemiennik częstotliwości
falownik
MSI
silnik indukcyjny
przepięcie
prąd doziemny
intermediate frequency inverter
inverter
PWM
induction motor
overvoltage
earth leakage current
Opis:
W referacie przedstawiono analizę współpracy pośrednich przemienników częstotliwości z zasilanymi przez nie silnikami indukcyjnymi. Na warunki pracy silników zasilanych z pośrednich przemienników częstotliwości mają w warunkach kopalnianych wpływ parametry elementów pasożytniczych użytych przewodów oponowych lub/i kabli górniczych, parametry elementów wchodzących w skład filtrów oraz sposób sterowania pracą zaworów falownika. Istotną właściwością omawianego przekształtnika jest to, że nie jest on źródłem napięcia sinusoidalnie zmiennego. Odkształcenie napięcia wyjściowego przemiennika jest efektem wielokrotnej komutacji zaworów falownika pracującego przy sterowaniu z modulacją szerokości impulsów (MSI). Z komutacją zaworów falownika związane są duże stromości narastania napięcia wyjściowego przemiennika. Stromości te osiągają wartości dochodzące do kilkunastu kV na s. Tak duże stromości narastania napięcia wyjściowego przemiennika powodują w stanie przejściowym przepływ dużych prądów pojemnościowych. W pracy omówiono wpływ poszczególnych parametrów kabli i przewodów oponowych na wartości przepięć i prądów doziemnych. Omówiono również sposoby ograniczenia tych niekorzystnych zjawisk (przepięć, prądów doziemnych).
The paper contains analysis of cooperation between induction motors with the intermediate frequency inverters that supply them. In the mine environment, parasitic elements of the cables, parameters of the filters’ elements, and a method of control over inverter transistors have an impact on the regime of motors fed by the intermediate frequency inverters. An important feature of such a converter is that it is not a source of sinusoidal voltage. Deformation of voltage output is a result of inverter transistors being switched up multiple times with pulse – width modulation (PWM) control. Large steepness of the converter output rising voltage is related to switching of the transistors. The steepness reaches values of up to a dozen or so kV on s. Such a large steepness of output rising voltage can cause passage of large capacitive currents. The paper discusses also the influence of the parameters of individual cables on values of the overvoltages and earth leakage currents. Various ways to limit this negative phenomena (overvoltage, the earth leakage current) are also discusses in the paper.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2017, 6, 2; 188-196
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Falownik napięciowy oparty na potrójnym mostku H do zasilania silnika trójfazowego z przerwaną fazą
Three phase motor with open phase supplied from voltage inverter based on triple h bridge
Autorzy:
Radecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1369107.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
falownik napięcia
silnik trójfazowy
three-phase motor
voltage inverter
Opis:
In this paper, a voltage inverter based on three independent H-bridges to supply health and faulty motor was presented. Operating conditions of this type of inverter were presented for each open phase. For proposed control scheme that refers to independent control of each phase current, a robust properties of control system was shown. Based on computer simulations and laboratory tests, the effectiveness of squirrel cage induction motor control, supplied from three independent H-bridges was shown in case of dynamic phase opening.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 1, 94; 115-120
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and simulation of novel stepped DC coupled quasi Z-Multilevel Inverter for single phase systems
Autorzy:
Meenakshi, T.
Suthanthira Vanitha, N.
Powiązania:
https://bibliotekanauki.pl/articles/140968.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multilevel inverter
shoot through
quasi Z-Source
modulation index
Opis:
This paper presents the modeling and simulation of a novel topology of quasi Z-Multilevel Inverter with stepped DC input. The proposed inverter incorporates a simple switching technique with reduced component count and is aimed at producing boosted multilevel output AC voltage. The inverter consists of two stages and the buck /boost operation is obtained by varying the shoot through period of the pulses obtained by maximum constant boost control with third harmonic injection. With all the advantages of the quasi Z-network, the proposed inverter eliminates the fly back diodes and capacitors present in a conventional Z-Multilevel Inverter. Further the stress on the devices is less which leads to reduction in component value and hence the cost. The novel stepped DC coupled Single Phase quasi Z-Multilevel Inverter is modeled and simulated in the MATLAB – SIMULINK environment and its performance is analyzed for varying input and switching conditions. The voltage and current waveforms across each stage of the inverter is analyzed and the results are presented for different levels of input.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 437-448
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of space vector modulation strategy on hybrid (Si-SiC) inverter losses
Autorzy:
Bonisławski, M.
Hołub, M.
Powiązania:
https://bibliotekanauki.pl/articles/140592.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik hybrydowy
elektronika energetyczna
urządzenie z szeroką przerwą energetyczną
SVPWM
DPWM
power electronic inverter
SiC diodes
hybrid inverter
wide band gap devices
Opis:
This work summarizes efficiency measurement results of a full bridge, 3 phase inverter composed of state-of-the-art Si IGBT transistors and Si or SiC diodes. Different (symmetrical and discontinuous) space vector modulation strategies were chosen in order to examine their influence (together with modulation frequency) on inverter losses. Induction machine was used as load, different load points were examined. Results clearly show, that proper modulation strategy, minimizing the switching losses of semiconductor switches, can increase the overall output efficiency at about 1% in case of both silicon and hybrid constructions. The drawback of DPWM approach is connected with the decreased quality of inverter output current. Hybrid technology can also improve the output efficiency at about 1% when compared to traditional constructions, but only in case of elevated switching frequencies. At low frequencies (below 10 kHz) modern semiconductor offer comparable results at much lower device costs.
Źródło:
Archives of Electrical Engineering; 2012, 61, 1; 69-75
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A closed-loop power controller model of series-resonant-inverter-fitted induction heating system
Autorzy:
Pal, P.
Roy, D.
Datta, A.
Sadhu, P. K.
Banerjee, A.
Powiązania:
https://bibliotekanauki.pl/articles/141721.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction heating
power controller
PID
series resonant inverter
MATLAB
Opis:
This paper presents a mathematical model of a power controller for a high-frequency induction heating system based on a modified half-bridge series resonant inverter. The output real power is precise over the heating coil, and this real power is processed as a feedback signal that contends a closed-loop topology with a proportional-integral-derivative controller. This technique enables both control of the closed-loop power and determination of the stability of the high-frequency inverter. Unlike the topologies of existing power controllers, the proposed topology enables direct control of the real power of the high-frequency inverter.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 827-841
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model trakcyjnego falownika napięciowego
The model of the voltage traction inverter
Autorzy:
Dominikowski, B.
Pacholski, K.
Woźniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/312485.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
falownik napięciowy
SVPWM
sieć trakcyjna
voltage inverter
traction line
Opis:
W artykule przedstawiono model falownika napięciowego typu DC/AC wykorzystywany w zmodernizowanych elektrycznych zespołach trakcyjnych (EZT). W przekształtniku tym wykorzystano metodę sterowania typu SVPWM (ang. Space Vector Pulse Width Modulation), która pozwala w sposób dokładny odwzorować na jego zaciskach wyjściowych przebiegi napięcia sinusoidalnie zmiennego. Obwód tego typu pracujący w sieci trakcyjnej generuje tętnienia wartości wejściowego prądu o częstotliwości sześciokrotnie wyższej niż częstotliwość jego napięcia wyjściowego. Na wejściu DC obwodu pośredniczącego falownika w elektrycznej trakcji szynowej monitoruje się wartość prądu obciążenia sieci jezdnej m.in. do wyznaczenia pobieranej energii elektrycznej pobranej przez zespół trakcyjny.
In the paper presented the model of the voltage inverter type DC/AC used in modernized electrical traction. In this inverter, the SVPWM (Space Vector Pulse Width Modulation) control method was used which allow to the accurately imitate the voltage sinusoidal variable waveforms on its output connectors. The circuit of this type working in overhead contact line generates pulsations of input-current at a frequency six times higher than the frequency of its output voltage. At the DC input of the inverter circuit in the electric traction rail, the load current of the mains network is monitored. to determine the electricity consumed by the traction unit.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 815-818, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ elementów obwodu elektrycznego na sprawność urządzenia spawalniczego
The influence of electrical circuit elements on the efficiency of welding machine
Autorzy:
Stopczyk, W.
Nawrocki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1368009.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
sprawność energetyczna
spawarka inwertorowa
IGBT
energy efficiency
inverter welder
Opis:
Rising energy costs and problems associated with load capacity of energy sources and environmental protection are the reasons for which it becomes expedient to search for new solutions of circuits welding equipment. Due to the relatively high power ratings of welding equipment, even a small increase in the efficiency of these devices can bring significant benefits. One way to increase the efficiency of welding machines are resonant power conversion techniques. The advantage of these circuits is elimination of switching losses and higher operating frequency compared to conventional circuits. In order to adequately take advantage of the resonance techniques to maximize efficiency of welding equipment, items to build a circuit welder should be selected. The article presents the results of research and discusses the influence of switching elements to improve the efficiency of welding equipment.
Rosnące koszty energii oraz problemy związane z obciążalnością źródeł energii i ochroną środowiska są powodami, dla których staje się celowe poszukiwanie nowych rozwiązań układowych urządzeń spawalniczych. Ze względu na stosunkowo duże moce znamionowe urządzeń spawalniczych, nawet niewielkie zwiększenie sprawności tych urządzeń może przynieść znaczące korzyści. Jednym ze sposobów pozwalających zwiększyć sprawność urządzeń spawalniczych są techniki rezonansowe konwersji energii. Zaletą tych układów jest eliminacja strat przełączania i wyższa częstotliwość pracy w porównaniu z układami klasycznymi. Aby dostatecznie wykorzystać zalety techniki rezonansowej i zmaksymalizować sprawność urządzenia spawalniczego należy właściwie dobrać elementy do budowy obwodu elektrycznego spawarki. W artykule zostały przedstawione wyniki badań oraz omówiony został wpływ elementów przełączających na poprawę sprawności urządzeń spawalniczych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 2, 106; 21-27
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the accuracy of inverter sync angle during the grids disturbances
Autorzy:
Jarzyna, Wojciech
Zieliński, Dariusz
Gopakumar, K.
Powiązania:
https://bibliotekanauki.pl/articles/221529.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inverter synchronization
synchronization angle
PLL
sync error
distributed grid
Opis:
The grid-tied inverter synchronizes with the network on the basis of the instantaneous voltage phase angle. This angle is computed by the so-called synchronization algorithms. During grid disturbances, it is estimated with a certain accuracy, which varies for different disturbances and depends on the choice of algorithm. The tests presented here determine how to make an optimal selection of the synchronization algorithm. The research methods used are modeling, simulation and analysis of the results obtained. One of the most important outcomes is the determination of the root-mean-square sync error and its dynamics denotation. The research conclusions should be of particular interest to designers of distributed energy systems with a large number of inverter energy sources.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 355-371
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiększenie częstotliwości łączeń w falownikach dzięki nowym elementom półprzewodnikowym z węglika krzemu (SiC)
Autorzy:
Zdanowski, M.
Sobieski, R.
Powiązania:
https://bibliotekanauki.pl/articles/302847.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
falownik
element półprzewodnikowy
węglik krzemu
inverter
semiconductor element
silicon carbide
Opis:
Doskonałe właściwości statyczne i dynamiczne tranzystorów SiC MOSFET mogą być wykorzystane do przesunięcia obecnej bariery częstotliwości łączeń, występującej w dotychczas stosowanych krzemowych (Si) elementach półprzewodnikowych falowników napięcia w zakres nawet powyżej 100 kHz.
Źródło:
Napędy i Sterowanie; 2017, 19, 3; 22-24
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decomposition of EMI Noise into Common and Differential Modes in PWM Inverter Drive System
Autorzy:
Kempski, A.
Smoleński, R.
Powiązania:
https://bibliotekanauki.pl/articles/262576.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
electromagnetic compatibility
common mode
differential mode
PWM inverter drive system
Opis:
In this paper [20] an analytical approach to decomposition of total phase EMI noises through algebraic calculations and the Fourier transform has been presented. Separating conducted EMI noise into different, common and differential mode (CM and DM) HF current components is important for a proper spectral analysis and application of EMI mitigation techniques. The results of calculations have been compared to EMI currents measured on the motor side of the PWM drive system. The proposed approach can be useful in comparative analysis of the influence of inverter control algorithms on spectra of CM currents in a given drive system.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 53-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System automatycznego sterowania w pomiarach przepływem wody
The automatic control system in flow measurement
Autorzy:
Szlachta, A.
Odon, A.
Powiązania:
https://bibliotekanauki.pl/articles/268597.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
falownik
przepływomierz
regulator PID
LabVIEW
inverter
flow meter
PID controller
Opis:
Artykuł prezentuje system automatycznego sterowania przepływem wody w obiegu zamkniętym. Omówiono aplikację sterującą przepływem wody na stanowisku. Zaprezentowano wieloczujnikowy system pomiarów. Na omawianym stanowisku przeprowadzane są badania metod statystycznych w pomiarach dwufazowych.
The system of automatic control of the water flow in a closed circuit has been presented in this paper. The laboratory stand allows to control the inverter on the position of research flows. Measurements were concerned a liquid in two-phase (water and air). The application to control the water flow was also discussed. The multi-sensors measurement system was presented. The laboratory stands have been realized for the results verification made obtained from mathematical models, computer simulations and signals acquisition using the stochastic methods. The statistical methods in the measurement of two-phase of statistical methods used in time delay estimation: direct cross-correlation and the function of conditional average value of delayed signal were carried out in the study for this stand.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 137-140
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Initial Excitation Issues of Synchronous Generator with VSI Inverter in Varying Rotational Speed Operation
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/2064987.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
synchronous generator
initial excitation
FOC control
voltage source inverter
synchronization
Opis:
Synchronous self-excited generators still are and probably will be the most popular 3-phase alternators installed in inland power stations so onboard of seagoing ships. Because of fuel savings and environmental restrictions Diesel, dual-fuel and gas propulsion engines for alternators of wide-range varying revolutions drives are increasingly used. There must be efficient way of creating 3-phase voltages of desired constant parameters ensured when generator produces variable amplitudes and frequencies of voltages because of changing rotational speed. As the control method modified field oriented control widely used with squirrel cage induction machines was chosen. This control method involves decoupling of currents and control voltages to flux and torque components and keeping them in optimal (orthogonal) condition. In order to obtain proper excitation and operation of such generator several factors have to be taken into account. Nonlinear dependence of voltage generated from rotational speed of self-excited synchronous generator is one of the factors that affects initial excitation process thus specific control method while generator startup. Theoretical background of synchronous generator excitation and voltage source inverter adopted FOC control method along with experimental results obtained in laboratory test bench of 5,5 kW generator and conclusions were presented.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 377--383
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca układu napędowego drzwi kabinowych z silnikiem synchronicznym przy zasilaniu awaryjnym
Cabin Door Drive System with Synchronous Motor Powered by Emergency Battery
Autorzy:
Kolano, K.
Powiązania:
https://bibliotekanauki.pl/articles/1368558.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
zasilanie awaryjne
przekształtnik
synchronous motor
emergency power
inverter
Opis:
The article presents the basic assumptions of technical operation of the propulsion system of a passenger elevator cabin door powered by emergency battery. It is highly reccomended for electric driver system of the lift doors, to open and close several times when supplying by the emergency battery. It is necessary to develop a control algorithm of synchronous motor operation to provide proper operation of the system performance at lower power. The developed procedure has been tested in the laboratory of the Department of Electrical Machines and Drives, and will be implemented into industrial practice in the New cabin door drive system.
W artykule przedstawione zostały podstawowe założenia techniczne pracy układu napędowego drzwi kabinowych dźwigu osobowego przy zasilaniu ze źródła rezerwowego. Podstawowym wymogiem jest umożliwienie otwarcia drzwi dźwigu po wykonaniu zjazdu awaryjnego z możliwie jak najmniejszą mocą przy wykorzystaniu tylko jednego akumulatora rezerwowego. Aby umożliwić poprawną pracę układu przy obniżonych parametrach zasilania konieczne jest opracowanie specjalnego algorytmu sterowania uwzględniającego charakterystykę pracy silnika synchronicznego. Opracowana procedura została przetestowana w laboratorium Katedry Napędów i Maszyn Elektrycznych i zostanie wdrożona do praktyki przemysłowej w nowym układzie napędowym drzwi kabinowych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 251-254
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania falownikowego napędu pompy wodnej z silnikiem indukcyjnym
The Test Inverter Drive the Water Pump with an Induction Motor
Autorzy:
Drabek, T.
Rusek, J.
Powiązania:
https://bibliotekanauki.pl/articles/1368614.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
diagnostyka
napęd falownikowy
induction motor
diagnostics
inverter driver
Opis:
This paper presents the results of tests of induction water pump drive with an inverter, installed In water supply station. The drive consists of induction motor with a power rating of 132kW, supplyed from voltage inverter with a power rating of 160kW, scalar controlled. The aim of the study was to determine the causes of repeated failures of the inverter. Subject of tests and diagnostic measurements was both, the inwerter and motor. Tests have shown the absence of any abnormalities in the operation of motor, including the lack of damage to the stator and rotor. Over the long-term measurements, there was no overvoltage in the feed of the inverter and the other sections of the drive circuit, that could cause damage of the drive. The conclusion of the tests is to identify the noise in control of the drive as the alleged source of the damage in its power module.
W artykule przedstawiono wyniki badań falownikowego napędu indukcyjnego pompy wodnej, zainstalowanego w wodociągach miejskich. Badany napęd składa się z głębinowego silnika indukcyjnego o mocy znamionowej 132kW, zasilonego z przemiennika częstotliwości o mocy znamionowej 160kW, sterowanego skalarnie. Celem badań było ustalenie przyczyn powtarzających się uszkodzeń części mocy przemiennika. Przedmiotem pomiarów kontrolnych i diagnostycznych był zarówno przemiennik jak i silnik. Badania wykazały brak jakichkolwiek nieprawidłowości w pracy silnika, w tym brak uszkodzeń stojana i wirnika. W ciągu pomiarów długookresowych stwierdzono również brak ew. przepięć na zasilaniu przemiennika i w innych punktach obwodu zasilania napędu, które mogłyby powodować uszkodzenia przemiennika. Konkluzją badań jest wskazanie zakłóceń sterowania samego przemiennika jak domniemanego źródła uszkodzeń jego części mocy.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 13-18
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A wide-band power electronics current source in reference current generator
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/97463.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
control algorithm
DSP
inverter
PWM
stability of an electrical system
Opis:
The paper considers wide-band voltage controlled power electronics current source. The current source has been designed as a part of 1-channel reference current generator designed for current meters testing. The control module of the generator utilizes a specialized Analog Devices Inc. DSPs based microcomputer module for power electronics applications. Used solutions have allowed obtain high quality referencing of the output current within reference signal. The paper presents the structure and selected aspects of the control algorithm of the current source. Also selected investigations results of the laboratory prototype of generator are presented.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 252-257
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on topology of a novel three-phase four-leg fault-tolerant NPC inverter
Autorzy:
Zhang, Baoge
Ping, Shanyan
Long, Yyi
Jiao, Yyuemin
Wu, Bboxiang
Powiązania:
https://bibliotekanauki.pl/articles/2086722.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault tolerant operation
midpoint potential equilibrium
NPC inverter
topology reconstruction
Opis:
Diode neutral point clamped (NPC) three-level converters have been widely used in recent years. Aiming at the problems of the high device failure rate and unstable neutral point potential of NPC three-level converters, an NPC three-level circuit with fourth bridge arm redundancy is proposed based on the traditional NPC three-level converter. The redundant fourth bridge arm is used to realize the function of stabilizing voltage when there is no fault and replacing the fault half-bridge arm to maintain the continuous operation of the converter when there is a fault. By analyzing the working principle of space vector pulse width modulation (SVPWM) and the power loss of the switch, it is of particular significance to the design and control of NPC three-level converters in the future. Matlab/Simulink verifies the feasibility of the fault-tolerant circuit structure.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 489--506
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steady-state time-periodic finite element analysis of a brushless DC motor drive considering motion
Autorzy:
Jagieła, M.
Gwóźdź, J.
Powiązania:
https://bibliotekanauki.pl/articles/141576.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
finite elements
brushless machines
inverter drives
steady-state
mathematical modeling
Opis:
This paper aims at providing a framework for comprehensive steady-state time-domain analysis of rotating machines considering motion. The steady-state waveforms of electromagnetic and circuit quantities are computed via iterative solution of the nonlinear field-circuit-and-motion problem with constraints of time periodicity. The cases with forced speed and forced load torque are considered. A comparison of execution times with a conventional time-stepping transient model is carried out for two different machines. The numerical stability of a time-periodic model with forced speed is shown to be worse than that of traditional transient time-stepping one, although the model converges within a reasonable number of iterations. This is not the case if forced load via equation of mechanical balance is accounted for. To ensure convergence of the iterative process the physical equation of motion is replaced by the fixed-point equation. In this way the model delivers time-periodic solutions regarding not only the electromagnetic quantities but also the rotational speed.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 471-486
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of maximum power point tracking in photovoltaic system under variable solar irradiance
Autorzy:
Marańda, W.
Piotrowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/200627.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photovoltaics
MPP-tracking
inverter efficiency
fotowoltaika
śledzenie
MPP
sprawność falownika
Opis:
Field conditions decrease the energy output of photovoltaic (PV) systems, mainly due to excessive temperatures. However, in regions with moderate ambient temperatures, as in Poland, solar energy is commonly delivered with highly fluctuating irradiance. This introduces yet another source of energy losses due to the non-ideal tracking of actual position of Maximum Power Point (MPP). Majority of PV-systems are equipped with DC/AC and grid-connected inverter. Since the solar energy flux is variable, an adequate MPP-tracking algorithm is required to handle a wide range of load levels and face rapid changes of input power. Along with the essential DC/AC conversion, the quality of MPP-tracking must also be taken into account in evaluation of inverter efficiency. The tracking in dynamic conditions has been addressed only recently. Several algorithms has been studied theoretically, experimentally or in laboratory conditions by applying artificial input test-patterns. This work takes the opposite approach by applying the recorded real-life solar irradiance and simulating the tracking behavior to study the problem for true field conditions in Poland. The simulation uses the unique high-quality irradiance data collected with 200 ms time resolution. The calculation of both static and dynamic MPP-tracking efficiency has been performed for representative variable-cloudy day, applying commonly used Perturb&Observe tracking algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 4; 713-721
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sub-phase power electronics inverters
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/97361.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inverter
Generalized Sampling Expansion
Whittaker-Kotelnikov-Shannon sampling theorem
WKS
Opis:
Dynamic changes of parameters of energy sources and receivers are reasons that decrease exactitude of output signals towards reference signals. To improve these parameters more advanced solutions of power electronics systems are necessary. Ones of possible solutions are a sub-phase inverters. The output quantity regulator there is based on Generalized Sampling Expansion, being crucial extension of Whittaker-Kotelnikov-Shannon sampling theorem. Wide-band power electronics current source with regulator based on that extension is analyzed further.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 190-199
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of numerically determined noise of a 290 kW induction motor using FEM and measured acoustic radiation
Autorzy:
Nahlaoui, M. Al
Steins, H.
Kulig, S.
Exnowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/140646.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inverter-fed
induction motor
asynchronous machine
acoustic radiation
modal analysis
Opis:
In this paper a comparison of numerically determined and measured electromagnetically exited noise of an induction motor is presented. The calculations are accomplished using FEM for an example motor, which is a 290 kW inverter-fed asynchronous machine. The approach starts with the electromagnetic and mechanical consideration. The focus is set on acoustic considerations, which contain the 3D-FE-model and measurement setup in the sound chamber.
Źródło:
Archives of Electrical Engineering; 2013, 62, 2; 195-207
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multilevel inverter with optimal THD through the firefly algorithm
Autorzy:
El Mehdi Belkacem, R.
Benzid, R.
Bouguechal, N.
Powiązania:
https://bibliotekanauki.pl/articles/141495.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
firefly algorithm (FFA)
genetic algorithm (GA)
inverter
multilevel
optimized THD
Opis:
Reduction of the Total Harmonic Distortion (THD) in multilevel inverters requires resolution of complex nonlinear transcendental equations; in this paper we propose a combination of one of the best existing optimized hardware structures with the recent firefly algorithm, which was used to optimize the THD, through finding the best switching angles and guaranteeing the minimization of harmonics within a user defined bandwidth. The obtained THD through the simulation of the thirteen-level symmetric inverter has been reduced down to 5% (FFT of 60 harmonics). In order to validate the simulation results, a thirteen-level symmetric inverter prototype has been made, and practically experimented and tested with different loads. Consequently, the measured THD with resistive load was 4.7% on a bandwidth of 3 kHz. The main advantage of the achieved work is the reduction of the THD.
Źródło:
Archives of Electrical Engineering; 2017, 66, 1; 141-154
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on hybrid topology of single-switch ICPT for battery charging
Autorzy:
Zhang, Guangzong
Wang, Chunfang
Zheng, Jianfen
Li, Houji
Powiązania:
https://bibliotekanauki.pl/articles/949898.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
constant current
constant voltage
higher harmonics
ICPT
single-switch
inverter
Opis:
In order to realize constant current and constant voltage charging for batteries by inductively coupled power transfer (ICPT) technology, a single-switch CL/LCL circuit is designed. The single-switch CL/LCL circuit is composed of a CL/LCL compensation network and single-switch inverter. The proposed circuit is compared with the traditional constant current and constant voltage circuit in the structure. The operating process of the single-switch CL/LCL circuit and the principle to realize a zero-voltage switch (ZVS) are analysed in detail in this paper. The voltage gain and current gain of the circuit are calculated, which demonstrates that the circuit is able to suppress higher harmonics strongly. By using Fourier decomposition, the voltage on the primary-side compensation capacitor can be obtained. After constructing the equivalent mutual inductance model of the circuit, the formulas and parameters are deduced and calculated. Finally, an experiment platform is built to verify the proposed circuit can realize constant current and constant voltage.
Źródło:
Archives of Electrical Engineering; 2020, 69, 4; 841-855
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Torque ripple calculation of a permanent magnet synchronous motor supplied by a three phase inverter with PWM
Autorzy:
Zaskalicky, P.
Powiązania:
https://bibliotekanauki.pl/articles/1372789.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
magnes trwały
przekształtnik
synchronous motor
permanent magnet
inverter
Opis:
A steady-state analysis of a permanent magnet synchronous motor drive with a voltage-source inverter is presented. The torque-speed profile required of the drive is a constant torque region from zero to the base speed and a constant power region above base speed. A Fourier series approach is used to predict the line current waveform. Assuming the output inverter's voltage is controlled by a pulse-width notching. Suppose the notching frequency to be constant for all frequency of the fundamental squarewave and to be fixed on 500 Hz. The permanent magnet synchronous motor model is obtained from its analogy to the fixed-excited synchronous motor. From the induced voltage and line current waveforms the electromagnetic torque ripple waveform is calculated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 88; 81-86
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault tolerant control of a PMSM drive in the selected emergency conditions
Autorzy:
Siembab, K.
Powiązania:
https://bibliotekanauki.pl/articles/376452.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
PMSM
PMSM drive
fault-tolerant inverter
FTC
Fault Tolerant Control
Opis:
The paper describes an investigation of fault tolerant control strategies for permanent magnet synchronous motor (PMSM) driven by a fault-tolerant inverter. The inverter is a topology-modified inverter with fault-tolerant capability, which can be configured as the standard 3-phase 6-switch inverter and reconfigured as 3-phase 4-switch or 2-phase 4-switch inverter under the fault condition. By analyzing operating principle of a fault-tolerant inverter and the mathematical model of PMSM, fault tolerant control algorithms are investigated. There is a conclusion that three phase stator windings of PMSM can be effectively operated by controlling only two phase currents. Simulation results show the validity of the proposed methods.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 75; 165-172
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of a permanent magnet motor with an inverter in a drive system of a car. Part 2
Autorzy:
Pawelski, Z.
Uszpolewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/245003.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
electrical machines
permanent magnet motor
inverter
electric drive control system
Opis:
The article presents a mathematical model of a permanent magnet motor, powered by a three-phase source of sinusoidal voltage, and a control method. Cooperation between numerical integration algorithms in the differential equation system of the motor and an inverter has been verified. The results of numerical simulations are presented in a graphic form. This article is an extension of the publication [12], in which a model of a drive system was proposed, consisting of: a battery, a supercapacitor and a method of controlling these energy sources during a driving cycle of a vehicle. For vector control, the mathematical model of a synchronous machine in the dq coordinate system is the most common one. The most important feature of this control method is the fact that the iq component of the rotor current vector determines the value of motor torque, and the component id – the value of magnetic flux. In the article, the emphasis is put on how inverters work. Their basic task is to generate such currents iabc or voltages uabc to obtain torque without ripples. It leads to development of different control concepts for achieving this goal, which are related to the modelling of magnetic fluxes in a stator and in an inverter.
Źródło:
Journal of KONES; 2018, 25, 4; 325-335
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przemiennik częstotliwości jako nieliniowy odbiornik energii
Frequency inverter as a non-linear energy loads
Autorzy:
BARTMAN, Jacek
SOBCZYŃSKI, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/455461.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rzeszowski
Tematy:
nieliniowe odbiorniki energii przemiennik częstotliwości
non-linear energy loads
inverter
Opis:
Artykuł przedstawia zagadnienia związane z pracą nieliniowych odbiorników energii. Określa, jakie odbiorniki uznaje się za nieliniowe, a jakie za liniowe. Jako przykład odbiornika nieliniowego pokazany jest przemiennik częstotliwości pracujący w układzie napędowym z regulowaną prędkością obrotową. Pokazano odkształcenia napięcia i prądu wywołane pracą napędu.
The work presents the issues associated with the functioning of non-linear receivers of the energy. It determines, what receivers are being regarded non-linear and which too linear. As the example of the non-linear receiver a inverter working in the driving system with the adjusted rotation speed is shown. Showing voltage and current distortion caused by the drive.
Źródło:
Edukacja-Technika-Informatyka; 2016, 7, 4; 394-399
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Particle swarm optimization of an iterative learning controller for the single-phase inverter with sinusoidal output voltage waveform
Autorzy:
Ufnalski, B.
Grzesiak, L. M.
Gałkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/200271.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
iterative learning control
sine wave inverter
particle swarm optimization (PSO)
Opis:
This paper presents the application of a particle swarm optimization (PSO) to determine iterative learning control (ILC) law gains for an inverter with an LC output filter. Available analytical tuning methods derived for a given type of ILC law are not very straightforward if additional performance requirements of the closed-loop system have to be met. These requirements usually concern the dynamics of a response to a reference signal, the dynamics of a disturbance rejection, the immunity against expected level of system and measurement noise, the robustness to anticipated variations of parameters, etc. An evolutionary optimization approach based on the swarm intelligence is proposed here. It is shown that in the case of the ILC applied to the LC filter, a cost function based on mean squares can produce satisfactory tuning effects. The efficacy of the procedure is illustrated by performing the optimization for various noise levels and various requested dynamics.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 3; 649-660
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model symulacyjny i eksperymentalny przekształtnika solarnego współpracującego z siecią energetyczną
Simulation and experimental models of solar converter working with power grid
Autorzy:
Krystkowiak, M.
Gulczyński, A
Powiązania:
https://bibliotekanauki.pl/articles/159562.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
ogniwo PV
falownik
BOOST
algorytm MPPT
photovoltaic PV
inverter
MPPT algorithm
Opis:
W artykule zaprezentowano strukturę przekształtnika pełniącego funkcję sprzęgu między siecią energetyczną prądu przemiennego a źródłem energii odnawialnej – panelami fotowoltaicznymi (PV). Opisywane rozwiązanie odznacza się wysokim współczynnikiem sprawności, przy jednoczesnym zachowaniu bardzo dobrych parametrów jakościowych przekształcanej energii. W wyniku zastosowania falownika sieciowego pracującego w regulacji nadążnej prądu osiągnięto prąd sieciowy o małej zawartości niepożądanych harmonicznych i teoretycznie zerowej mocy biernej. Ze względu na sposób funkcjonowania ogniw fotowoltaicznych, których wydajność zależy nie tylko od panujących warunków atmosferycznych, ale również i od sposobu obciążenia, szczególną uwagę zwrócono na zaimplementowany algorytm MPPT. Jego zadaniem jest zapewnienie takiego punktu pracy ogniwa PV, aby podążać za punktem mocy maksymalnej zależnie od warunków pracy systemu. Przedstawiono również wybrane wyniki badań.
In this paper, the elaborated structures of the main circuit and control circuit of the power electronics converter working as a coupling between an energetic grid and photovoltaic panels were presented. The described solution is characterized by very good quality parameters of the transformed energy. To obtain a current network, which is very similar to a sine wave, the inverter working in a current tracking controller mode was used. Additionally the elaborated MPPT (Maximum Power Point Tracking) algorithm was described. With help of this algorithm the highest possible efficiency of the whole system was achieved. The chosen simulation and experimental results of research were analyzed.
Źródło:
Prace Instytutu Elektrotechniki; 2016, 273; 95-104
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of the Selection of P(U) and Q(U) Characteristic Parameters of Solar Microinverters
Optymalizacja doboru parametrów charakterystyk P(U) i Q(U) falowników mikroinstalacji fotowoltaicznych
Autorzy:
Pijarski, Paweł
Kacejko, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/952875.pdf
Data publikacji:
2019
Wydawca:
ENERGA
Tematy:
optymalizacja
mikroinstalacja PV
charakterystyka falowników
optimization
PV micro plant
inverter characteristics
Opis:
Currently, a dynamic increase can be observed in the number of photovoltaic plants connected to a low voltage grid. The phenomenon of power flow towards a transformer substation may cause the permissible voltage to be exceeded. There are several ways to eliminate the adverse voltage increases. In this article, the authors proposed a method for optimizing the selection of P(U) and Q(U) characteristics of solar plant inverters. The research shows that the use of inverters, for which both characteristics have been activated, allows to master the problem of voltage increase with a small reduction of the micro-plant output.
Obecnie można zaobserwować dynamiczny wzrost liczby instalacji fotowoltaicznych przyłączonych do sieci niskiego napięcia. Zjawisko przepływu mocy w kierunku stacji transformatorowej może spowodować przekroczenie dopuszczalnej wartości napięcia. Wyróżnić można kilka sposobów wyeliminowania niekorzystnych wzrostów napięcia. W artykule autorzy zaproponowali metodę optymalizacji doboru charakterystyk P(U) i Q(U) falowników instalacji fotowoltaicznych. Przeprowadzone badania wskazują, że zastosowanie falowników, dla których uaktywniono obydwie charakterystyki, pozwala na opanowanie problemu wzrostu napięć przy niewielkim ograniczeniu energii produkowanej w mikroinstalacjach.
Źródło:
Acta Energetica; 2019, 2; 14-19
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of reducing switch count in three-level NPC inverter – analysis in steady states
Autorzy:
Beniak, R.
Rogowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1193464.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reduction of switch count
three-level NPC inverter
space vector modulation
Opis:
The proof of a concept for a new method of modulation has been presented which reduce switch count in a three-level neutral point clamped (3L-NPC) inverter. The method is an implementation of space vector modulation (SVM) by means of a prediction algorithm and sequences of transistors, which are not common in use. Those sequences make active use of clamping diodes of the inverter. The prediction algorithm analyzes possible sequences of transistors’ states and choose those which offers smaller switch count. Measurements of steady states were taken on prototype 3L-NPC.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 117-126
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of a Subscription Based Community Solar Energy System for the Business Community of the “Back Gate”, Alex Ekwueme Federal University Ndufu-Alike, Ikwo, Ebonyi State, Nigeria
Autorzy:
Daniel, Thomas Ojonugwa
Obot, Enobong Patrick
Azuoko, George-Best
Negedu, Isaac Onuche
Amah, Orji
Powiązania:
https://bibliotekanauki.pl/articles/1818428.pdf
Data publikacji:
2020
Wydawca:
Instytut Polityki Energetycznej im. Ignacego Łukasiewicza
Tematy:
community solar energy
charge controller
inverter, battery
Smart meter
Photovoltaic array
Opis:
This study presents a model design of a subscription based community solar energy for the business community of the “Back gate”, Alex Ekwueme Federal University Ndufu-Alike Ikwo. The business community is largely dependent on the use of fossil fuel generators due to the absence of connection to the Nigeria national electricity grid. The extensive use of the fossil fuel is not only associated with environmental pollution and global warming but its reserve is also finite, non-renewable and expensive. This study presents the use of solar energy to supply the electrical energy need of twenty (20) business premises at the study location. The design was carried out according to the daily electrical load profile of the community, taking into consideration the solarirradiation data of the location, the geographical location and the weather condition. The sizing of each of the system components and the economic analysis of the system in terms of the life cycle cost and electricity unit cost was also taken into consideration. The subscription based community solar with smart meter control gives energy access at reduce cost, the total unit of consumption, unit balance and other energy status per time.The unit cost of electricity using the model design was determined as #0.078/kWh which is cheaper with real time energy costing via a smart meter thereby encouraging the usage of the energy system as an efficient system with enhanced energy accessibility, real time energy services, climate change adaption by reduction of greenhouse gas emission, clean energy development plans/implementation within the community and an investment platform for would-be investors and philanthropist.
Źródło:
Energy Policy Studies; 2020, 2 (6); 3--20
2545-0859
Pojawia się w:
Energy Policy Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling and simulation of sinusoidal pulse width modulation controller for solar photovoltaic inverter to minimize the switching losses and improving the system efficiency
Autorzy:
Panneerselvam, Sivaraj
Kandasamy, Karunanithi
Perumal, Chandrasekar
Powiązania:
https://bibliotekanauki.pl/articles/2135736.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
efficiency
IGBT
MOSFET
PV inverter
MATLAB/SIMULINK
SPWM controller
switching loss
Opis:
With the extinction of fossil fuels and high increase in power demand, the necessity for renewable energy power generation has increased globally. Solar PV is one such renewable energy power generation, widely used these days in the power sector. The inverters used for power conversion suffer from power losses in the switching elements. This paper aims at the detailed analysis on switching losses in these inverters and also aims at increasing the efficiency of the inverter by reducing losses. Losses in these power electronic switches vary with their types. In this analysis the most widely used semiconductor switches like the insulated gate bipolar transistor (IGBT) and metal oxide semiconductor field effect transistor (MOSFET) are compared. Also using the sinusoidal pulse width modulation (SPWM) technique, improves the system efficiency considerably. Two SPWM-based singlephase inverters with the IGBT and MOSFET are designed and simulated in a MATLAB Simulink environment. The voltage drop and, thereby, the power loss across the switches are compared and analysed. The proposed technique shows that the SPWM inverter with the IGBT has lower power loss than the SPWM inverter with the MOSFET.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 615--626
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Transformer Class E Amplifier
Autorzy:
Mikolajewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141694.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Class E amplifier
resonant inverter
DC-DC converter
transformer
leakage inductance
Opis:
In a high-efficiency Class E ZVS resonant amplifier a matching and isolation transformer can replace some or even all inductive components of the amplifier thus simplifying the circuit and reducing its cost. In the paper a theoretical analysis, a design example and its experimental verification for a transformer Class E amplifier are presented. In the experimental amplifier with a transformer as the only inductive component in the circuit high efficiency ηMAX = 0.95 was achieved for supply voltage VI = 36 V, maximum output power POMAX = 100 W and the switching frequency f = 300 kHz. Measured parameters and waveforms showed a good agreement with theoretical predictions. Moreover, the relative bandwidth of the switching frequency was only 19% to obtain output power control from 4.8 W to POMAX with efficiency not less than 0.9 in the regulation range.
Źródło:
Archives of Electrical Engineering; 2014, 63, 4; 621-633
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power injection control system and experimental model based on manufacturer characteristic curves for a photovoltaic generation system
Autorzy:
Rico, A.
Cadaval, E. R.
Montero, M. I. M.
Powiązania:
https://bibliotekanauki.pl/articles/262582.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
Inverter Current Controller (ICC)
Inverter Reference Current Generator (ICRG)
maximum power point tracking (MPPT)
Photovoltaic Cell (PV Cell)
PV Voltage and PV Current
VI characteristic equations
Opis:
This paper attempts to validate the performance of a power injection control block for Photovoltaic Generation Systems (PVGS). This device uses a control module based on detecting the power injected into the supply by the inverter, instead of measuring the power generated by the PVGS. The performance is evaluated using the concept of Maximum Energy Curve that takes into account both transient and permanent control performance. The paper presents a basic and simple procedure to obtain a model from the manufacturer characteristic curves of the photovoltaic cells. MATLAB Simulink is used as simulation tool to obtain the response of the proposed system to changes in temperature and irradiance.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 69-75
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation and experimental examinations of voltage inverter and synchronous generator synchronization system with the use of VisualDSP++ 5.0 environment
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/97413.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
synchronous generator
machine inverter
Radix–2 FFT
synchronization
DSP
real–time
Opis:
This study describes the operation of the programming algorithm used to synchronize the machine VSI inverter with the rotating synchronous generator. Presented algorithm which bases on the Radix–2 Fourier transform allows to synchronize the inverter with the machine with variable in wide range rotating speed. This study presents the results obtained with use of the simulation software and the auxiliary software created with the use of VisualDSP++ 5.0 development environment and exemplary results of an algorithm operation in the laboratory test stand.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 210-219
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of reducing switching losses in three-level NPC inverter
Autorzy:
Beniak, R.
Rogowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1193262.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reduction of switching losses
three-level NPC inverter
space vector modulation
Opis:
The aim of the paper is to present a concept of implementation of a space vector modulation (SVM) algorithm, which is used to create alternating current waveforms of changing amplitude and frequency in power inverters. The main goal of the method is to decrease the number of state changes in power transistors. It is realized by utilizing a prediction algorithm and sequences of transistors, which are not common in use. The method requires measurement of inverter output current flow. The prediction algorithm analyzes possible sequences of transistors’ states and choose those which offers smaller switch count. A decrease of about 20% was obtained for the cases tested. This paper presents simulation result for selected driving scenario. The described method decreases the number of state changes in power transistors and therefore it is a potentially good method to considerably decrease energy losses of multilevel inverter-powered drive.
Źródło:
Power Electronics and Drives; 2016, 1, 36/2; 55-63
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
Autorzy:
Strankowski, Patryk
Guziński, Jarosław
Wilczyński, Filip
Morawiec, Marcin
Lewicki, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/1193764.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
five-phase induction motor
inverter output filter
open-phase fault detection
Opis:
The paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves the reliability of the complete drive system. A new idea of online open-phase fault detection is presented based on the frequency analysis of the estimated observer variables. The test setup, fault operation capabilities and an experimental verification of the proposed fault detection method are presented in the paper.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 189-200
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of a Subscription Based Community Solar Energy System for the Business Community of the “Back Gate”, Alex Ekwueme Federal University Ndufu-Alike, Ikwo, Ebonyi State, Nigeria
Autorzy:
Daniel, Thomas Ojonugwa
Obot, Enobong Patrick
Azuoko, George-Best
Negedu, Isaac Onuche
Amah, Orji
Powiązania:
https://bibliotekanauki.pl/articles/1818436.pdf
Data publikacji:
2020
Wydawca:
Instytut Polityki Energetycznej im. Ignacego Łukasiewicza
Tematy:
community solar energy
charge controller
inverter, battery
Smart meter
Photovoltaic array
Opis:
This study presents a model design of a subscription based community solar energy for the business community of the “Back gate”, Alex Ekwueme Federal University Ndufu-Alike Ikwo. The business community is largely dependent on the use of fossil fuel generators due to the absence of connection to the Nigeria national electricity grid. The extensive use of the fossil fuel is not only associated with environmental pollution and global warming but its reserve is also finite, non-renewable and expensive. This study presents the use of solar energy to supply the electrical energy need of twenty (20) business premises at the study location. The design was carried out according to the daily electrical load profile of the community, taking into consideration the solarirradiation data of the location, the geographical location and the weather condition. The sizing of each of the system components and the economic analysis of the system in terms of the life cycle cost and electricity unit cost was also taken into consideration. The subscription based community solar with smart meter control gives energy access at reduce cost, the total unit of consumption, unit balance and other energy status per time.The unit cost of electricity using the model design was determined as #0.078/kWh which is cheaper with real time energy costing via a smart meter thereby encouraging the usage of the energy system as an efficient system with enhanced energy accessibility, real time energy services, climate change adaption by reduction of greenhouse gas emission, clean energy development plans/implementation within the community and an investment platform for would-be investors and philanthropist.
Źródło:
Energy Policy Studies; 2020, 2 (6); 3--20
2545-0859
Pojawia się w:
Energy Policy Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensorless five-phase induction motor drive with third harmonic injection and inverter output filter
Autorzy:
Strankowski, P.
Guzinski, J.
Morawiec, M.
Lewicki, A.
Wilczynski, F.
Powiązania:
https://bibliotekanauki.pl/articles/200259.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sensorless control
five-phase induction motor
inverter output filter
multiscalar control
Opis:
The paper presents a sensorless control approach for a five-phase induction motor drive with third harmonic injection and inverter output filter. In the case of the third harmonic injection being utilised in the control, the physical machine has to be divided into two virtual machines that are controlled separately and independently. The control system structure is presented in conjunction with speed and rotor flux observers that are required for a speed sensorless implementation of the drive. The last section is dedicated to experimental results of the drive system in sensorless operation, and the uninterrupted drive operation for two open-phase faults.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 3; 437-445
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of operation of class E ZVS resonant inverter
Autorzy:
Szychta, E.
Powiązania:
https://bibliotekanauki.pl/articles/262645.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
class E ZVS resonant
inverter
output capacitance
MOSFET transistor
zero voltage switching
Opis:
The article discusses class E zero-voltage-switching resonant inverter (ZVS). The resonant circuit of the inverter is subject to mathematical analysis using the method of state variables with the aid of MATLAB software. Results of simulation testing, based on Simplorer software, of an inverter at the operating frequency of 100kHz are presented.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 57-67
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new circuit topology using Z-source resonant inverter for high power contactless power transfer applications
Autorzy:
Ghosh, P. C.
Sadhu, P. K.
Ghosh, A.
Pal, N.
Powiązania:
https://bibliotekanauki.pl/articles/141006.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
contactless power transfer
mutual inductance
magnetic coupling coefficient
Z-source
resonant inverter
Opis:
In this study, a new circuit topology using a Z-source resonant inverter (ZSRI) for high power applications in large-air-gap contactless power transfer (CPT) systems, has been investigated. The main shortcoming of a large-air-gap CPT system is the poor power transfer efficiency due to low magnetic coupling. In order to minimize this shortcoming and to improve the overall performance of the system by boosting the power transfer capability, in this paper a CPT system with the newly developed circuit topology using high frequency Z-source resonant inverter has been proposed. Using the newly developed circuit topology for the CPT system, it has been observed that the overall performance of the system has been improved to a reasonable level with a purely sinusoidal resonant current flowing through the primary side. Therefore, no harmonics will be injected into the source. The proposed CPT system with an air gap of 16 cm and a misalignment of 3 cm has been simulated using the Maxwell finite element tool and Simplorer circuit simulation software for an output power of 2 kW.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 843-854
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on low frequency ripple suppression technology of inverter based on model prediction
Autorzy:
Liu, Haiyang
Chen, Yiwen
Luo, Sixu
Jiang, Jiahui
Jian, Haojun
Powiązania:
https://bibliotekanauki.pl/articles/24202730.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
boost type
low frequency ripple suppression
model predictive control
single stage inverter
Opis:
The low frequency ripple of the input side current of the single-phase inverter will reduce the efficiency of the power generation system and affect the overall performance of the system. Aiming at this problem, this paper proposes a two-modal modulation method and its MPC multi-loop composite control strategy on the circuit topology of a single-stage boost inverter with a buffer unit. The control strategy achieves the balance of active power on both sides of AC and DC by controlling the stable average value of the buffer capacitor voltage, and provides a current reference for inductance current of the DC input side. At the same time, the MPC controller uses the minimum inductor current error as the cost function to control inductor current to track its reference to achieve low frequency ripple suppression of the input current. In principle, it is expounded that the inverter using the proposed control strategy has better low frequency ripple suppression effect than the multi-loop PI control strategy, and the conclusion is proved by the simulation data. Finally, an experimental device of a single-stage boost inverter using MPC multi-loop composite control strategy is designed and fabricated, and the experimental results show that the proposed research scheme has good low frequency ripple suppression effect and strong adaptability to different types of loads.
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 443--460
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resonant DC link inverters for AC motor drive systems – critical evaluation
Autorzy:
Turzyński, Marek
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200688.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant DC link inverter
quasiresonant DC link inverter
common-mode voltage
voltage gradient
zero voltage switching
przekształtnik quasirezonansowy DC
gradient napięcia
przekształtnik rezonansowy DC/DC
Opis:
In this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing and winding insulation safety. Experimental records of the laboratory developed parallel quasiresonant DC link inverter feeding induction motor confirm results of analysis. Comparative tables and simulation results demonstrate characteristic features of various schemes.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 2; 241-252
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechatronic system with the control of voltage in permanent magnet synchronous generator
Autorzy:
Tarnapowicz, D.
German-Galkin, S.
Powiązania:
https://bibliotekanauki.pl/articles/27315954.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
PMSG
voltage regulation of PMSG
active inverter
regulacja napięcia PMSG
falownik aktywny
Opis:
In recent years, the use of Permanent Magnet Synchronous Generator (PMSG) in ship power plant system has increased. PMSGs are characterized by better properties than the classic and commonly used synchronous generators. In comparison with classic synchronous generators, PMSGs do not have a voltage regulator, and hence as the load increases, the voltage at the output of the generator decreases. The article presents the use of an active voltage inverter with the task to maintain a constant voltage on the receiver along with the load’s increase. Simulation studies confirming the effectiveness of the proposed method were carried out
Źródło:
New Trends in Production Engineering; 2018, 1, 1; 531-537
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model predictive direct power control of energy storage quasi-Z-source grid-connected inverter
Autorzy:
Tang, Min'an
Yang, Shangmei
Zhang, Kaiyue
Wang, Qianqian
Liu, Chenggang
Dong, Xuewang
Powiązania:
https://bibliotekanauki.pl/articles/2042769.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
quasi Z-Source
inverter
energy storage
power control
model predictive
space vector
Opis:
In order to overcome the shortcoming of large switching losses caused by variable switching frequency appears in the conventional finite control set model predictive control (FCS-MPC) algorithm, a model predictive direct power control (MP-DPC) for an energy storage quasi-Z-source inverter (ES-qZSI) is proposed. Firstly, the power prediction model of the ES-qZSI is established based on the instantaneous power theory. Then the average voltage vector in the coordinate system is optimized by the power cost function. Finally, the average voltage vector is used as the modulation signal, and the corresponding switching signal with fixed frequency is generated by the shoot-through segment space vector pulse width modulation (SVPWM) technology. The simulation results show that the ES-qZSI realizes six shoot-through actions per control cycle and achieves the constant frequency control of the system, which verifies the correctness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 21-35
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CHB inverter with DC-link capacitor balancing and total harmonic minimization
Autorzy:
Armi, F.
Manai, L.
Besbes, M.
Powiązania:
https://bibliotekanauki.pl/articles/141332.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CHB inverter
capacitor voltage balancing
switching angles
Newton Raphson
algorithm
SHE
THD
Opis:
A cascaded H-bridge (CHB) multilevel inverter generally requires several DC sources. An alternative option is to replace the separate DC source feeding an H-bridge cell with a capacitor, while maintaining the other H-bridge cell with a real DC voltage source. In this paper a 7-level cascaded H-bridge inverter with a single DC-source is presented. This paper focuses mainly to achieve effective capacitor voltage balancing and selective harmonic elimination (SHE) based on the Newton Raphson algorithm (N–R). It shows hope to reduce the voltage ripple of the capacitors, which leads to higher power conversion efficiency with equal power distribution, reduces the initial cost, and complexity hence it is apt for industrial applications. Simulation results support the proposed control technique.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 81-93
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A New 13-Level Switched-Capacitor Inverter with Reduced Device Count
Autorzy:
Jena, Kasinath
Panigrahi, Chinmoy Kumar
Gupta, Krishna Kumar
Powiązania:
https://bibliotekanauki.pl/articles/1956000.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
switched capacitor
voltage gain
component per level factor
cost function
Opis:
This paper proposed a new voltage-boosting 13-level switched-capacitor (SC) cost-effective inverter. The proposed topology comprises fourteen transistors, three capacitors and a single DC source to produce a 13-level staircase waveform. The capacitor voltage balancing problem is inherently solved by the series/parallel technique. Structural description, working principle, calculation of optimum values of capacitance and modulation scheme are briefly described. The comparative analyses with the existing SC multilevel inverter (MLI) in terms of voltage gain, blocking voltage, total standing voltage (TSV), component per level factor and cost function illustrate the merits of the proposed topology. Further, simulation and experimental results at different loading conditions verify the feasibility of the proposed topology.
Źródło:
Power Electronics and Drives; 2021, 6, 41; 26-41
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of a single-phase inverter’s with voltage regulation
Autorzy:
Zaskalicky, P.
Zaskalicka, M.
Powiązania:
https://bibliotekanauki.pl/articles/2056350.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
model matematyczny
przekształtnik
regulacja napięcia
mathematical model
single-phase inverter
voltage regulation
Opis:
The paper deals with mathematical model of single-phase bridge inverters which outputs voltage is controlled by a pulse-width notching. The transistors in the inverter circuit are turned on and off so as to produce zero periods of equal length, for unipolar modulation, or negative voltage for bipolar modulation. The D.C. source is being a fixed level of voltage. Suppose the notching frequency to be constant for all frequency of the fundamental squarewaves and to be fixed on 500 Hz. The output inverter’s voltage is expressed by an analytical formula based on Fourier complex series. On the base of output voltage, the waveforms of the output currents are analytically calculated for different inverter’s loads.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2009, 83; 41-45
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cyfrowy automat sterujący urządzeń energoelektronicznych z wykorzystaniem modelu czasu rzeczywistego falownika
Digital state machine of power electronic device with the use of inverter’s real-time model
Autorzy:
BINKOWSKI, Tomasz
KWIATKOWSKI, Bogdan
Powiązania:
https://bibliotekanauki.pl/articles/456633.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rzeszowski
Tematy:
model czasu rzeczywistego
energoelektronika
falownik
sterowanie
real-time model
power electronic
inverter
control
Opis:
Artykuł przedstawia koncepcję stanowiska laboratoryjnego przeznaczonego do badań układów sterowania przekształtników energoelektronicznych. Zakłada się, że przekształtnik energoelektroniczny symulowany jest sprzętowo jako współbieżny proces w stosunku do testowanego układu sterowania. Jako platformę sprzętową wykorzystuje się układ o programowalnej strukturze logicznej umożliwiający testowanie procesu sterowania na modelu czasu rzeczywistego przekształtnika lub bezpośrednie sterowanie modelem laboratoryjnym. Jako przykład przedstawiono cyfrowy model falownika napięcia sterowany automatem realizującym przełączanie półokresowe. Prezentowana koncepcja ma zastosowanie w badaniach naukowych i dydaktyce.
The article presents the concept of the laboratory stand for testing of power electronic control systems. It is assumed that the converter unit and the control process are simulated in parallel as a hardware. The hardware platform uses the programmable logical structure for testing the control process on real time inverter model or can directly control the laboratory inverter model. The digital model of the inverter voltage controlled by digital state machine that makes half-period switching was used as an example. The presented concept is applicable in scientific research and teaching.
Źródło:
Edukacja-Technika-Informatyka; 2016, 7, 4; 387-393
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroprocesorowy układ sterowania 3-fazowego falownika napięcia MSI
Microprocessor control system for three-phase voltage inverters
Autorzy:
Legutko, P.
Powiązania:
https://bibliotekanauki.pl/articles/155421.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
falownik napięcia
układ sterowania
mikroprocesor
voltage inverter
control system
microprocessor
digital signal processor
Opis:
W artykule zaprezentowano mikroprocesorowy układ sterownika 3-fazowego falownika napięcia wykonany na bazie karty z procesorem sygnałowym. Dzięki zastosowaniu jednostki obliczeniowej typu DSP, układ sterowania charakteryzuje się wysoką wydajnością, co umożliwia realizację złożonych algorytmów sterowania w czasie rzeczywistym. Bogata architektura wewnętrzna procesora DSP zapewnia łatwą i szybką rozbudowę układu, dzięki czemu możliwe jest jego zastosowanie w różnych aplikacjach przemysłowych.
A control system for a 3-phase voltage inverter using DSP TMS320F28335 (Fig. 1) is the subject of the paper. The paper presents the microprocessor control system (Fig. 8) consisting of: a processor card, a keyboard interface with VFD display and a base board with high speed fiber optic transmitters (Fig. 6). The microprocessor control system was designed according to the requirements for a three-phase inverter (Fig. 2). The control method was verified by a universal laboratory in the Department of Power Electronics, Electrical Drives and Robotics of the Silesian University of Technology. Due to application of a floating point DSP (digital signal processor) unit, the system is characterized by the high efficiency, which enables it to realize complicated control algorithms in real time. The open microproces-sor control system architecture providing easy and fast development makes it possible to apply this system to industry. The microprocessor control system with a DSP unit is used for realiza-tion of complex control algorithms, e.g. the ones described in [1, 2].
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 721-724
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Economy and energy analysis in the operation of renewable energy installations – a case study
Autorzy:
Idzikowski, Adam
Cierlicki, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1839542.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
panel fotowoltaiczny
odnawialne źródła energii
falownik
solar panel
renewable sources of energy
inverter
Opis:
In the paper an economic, ecological and energy analysis of a home photovoltaic on grid installation was presented. The increase in ecological awareness of the Polish society contributes to the continuous growth of interest in green energy. However, many people haven’t been aware of the ecological, economic and energy benefits of photovoltaic installations yet, so the following analysis is made. The analysis concerns a photovoltaic installation with a capacity of 3.96 kWp located in Ościęciny near Włocławek. The photovoltaic installation consists of 11 monocrystalline panels with a power of 360 Wp, a 4 KTLM Sofar Solar inverter and other necessary components. The first part presents basic issues related to photovoltaic installations. Parameters related to the proper functioning of the photovoltaic installation were replaced. The analysis of the literature will help to understand the essence of the proper functioning of the photovoltaic installation. In the practical part, an analysis of a selected home photovoltaic installation was carried out. Based on the available data, it has been calculated that the installation will have a payback period of over 9 years. The photovoltaic installation will produce approximately 3 582.61 kWh of electricity and will contribute to the reduction of 70 tons of carbon dioxide during the entire operation.
Źródło:
Production Engineering Archives; 2021, 27, 2; 90-99
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of determining the COP coefficient for a cooling system
Sposób wyznaczenie współczynnika COP dla układu chłodniczego
Autorzy:
Rząsa, Mariusz
Pochwała, Sławomir
Szymaniec, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1841374.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
coefficient of performance
cooling system
inverter compressor
współczynnik COP
układ chłodniczy
sprężarka inwertorowa
Opis:
The basic metrological problem analyzed in this article is the experimental determination of the COP coefficient for arefrigerating system working in a stationary cooling chamber. This issue is because manufacturers of chillers provide the value of this coefficient in device technicaldata.In practice, after installing the refrigeration unit, the COP is often lower. The paper presents amethod of balancing cooling energy for a complete refrigeration system.
Podstawowym problemem metrologicznym, który autorzy pragną przedstawić jest eksperymentalne wyznaczenie współczynnika COP dla układu chłodniczego, pracującego w stacjonarnej komorze chłodniczej. Zagadnienie to jest istotne, ponieważ producenci agregatów chłodniczych najczęściej podają współczynnik COP dla agregatu chłodniczego. W praktyce po zamontowaniu agregatu chłodniczego w komorze chłodniczej współczynnik COP jest niejednokrotnie niższy. Trudność z wyznaczeniem współczynnika COP w układzie chłodniczym polega na koniczności zbilansowania mocy chłodniczej dla całego układu wraz z komorą chłodniczą. W pracy przedstawiono sposób bilansowania energii chłodniczej dla kompletnego układu chłodniczego oraz opisano budowę stanowiska do wyznaczania współczynnika COP.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 4; 69-72
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intermittent power smoothing control for grid connected hybrid wind/PV system using battery-EDLC storage devices
Autorzy:
Jayalakshmi, N.S.
Gaonkar, D.N.
Karthik, R.P.
Prasanna, P.
Powiązania:
https://bibliotekanauki.pl/articles/141664.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy storage devices
inverter controller
MPPT controller
power smoothing
PV system
wind power
Opis:
Wind and solar radiation are intermittent with stochastic fluctuations, which can influence the stability of operation of the hybrid system in the grid integrated mode of operation. In this research work, a smoothing control method for mitigating output power variations for a grid integrated wind/PV hybrid system using a battery and electric double layer capacitor (EDLC) is investigated. The power fluctuations of the hybrid system are absorbed by a battery and EDLC during wide variations in power generated from the solar and wind system, subsequently, the power supplied to the grid is smoothened. This makes higher penetration and incorporation of renewable energy resources to the utility system possible. The control strategy of the inverter is realized to inject the power to the utility system with the unity power factor and a constant DC bus voltage. Both photovoltaic (PV) and wind systems are controlled for extracting maximum output power. In order to observe the performance of the hybrid system under practical situations in smoothing the output power fluctuations, one-day practical site wind velocity and irradiation data are considered. The dynamic modeling and effectiveness of this control method are verified in the MATLAB/Simulink environment. The simulation results show that the output power variations of the hybrid wind/PV system can be significantly mitigated using the combination of battery and EDLC based storage systems. The power smoothing controller proposed for the hybrid storage devices is advantageous as compared to the control technique which uses either battery or ultracapacitor used for smoothing the fluctuating power.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 433-453
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground leakage current caused by Common-Mode Voltage of PWM inverter
Prądy upływu doziemnego generowane napięciem wspólnym falownika MSI
Autorzy:
Szymański, Jerzy Ryszard
Żurek-Mortka, Marta
Powiązania:
https://bibliotekanauki.pl/articles/106701.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
common-mode voltage
differential-mode voltage
PWM modulation
three-phase traction voltage inverter
two-level PWM inverter
dwupoziomowy falownik MSI
napięcie różnicowe
napięcie wspólne
modulacja MSI
trójfazowy trakcyjny falownik napięciowy
Opis:
In railway tractive vehicles, three-phase PWM (Pulse Width Modulation) inverters generate parasitic Differential-Mode Voltages (DMV) and Common-Mode Voltages (CMV). Parasitic voltages are a side effect of using the width modulation to shape the phase-to-phase inverter’s voltage. In this article, the authors present a mathematical description of the DM and CM voltages and carry out their spectral analysis. Based on the spectral harmonics analysis, the authors present a method for filtration of harmonics of DM and CM voltages aimed at limiting the capacitance parasitic currents: due to DM voltage – phase-to-phase parasitic current and CM voltage – ground parasitic currents. As the final result of the tests, almost complete elimination of leakage parasitic current form PE shock protection system was achieved.
W kolejowych pojazdach trakcyjnych trójfazowe falowniki MSI (Modulacja Szerokości Impulsów) wytwarzają pasożytnicze napięcia różnicowe (Differential Mode Voltage) i wspólne (Common Mode Voltage). Pasożytnicze napięcia są skutkiem ubocznym stosowania modulacji szerokościowej do kształtowania napięć międzyfazowych falownika. W artykule autorzy przedstawiają opis matematyczny napięć DM oraz CM i przeprowadzają ich analizę widmową. Na podstawie przeprowadzanej analizy autorzy przedstawiają metodę filtracji wybranych harmonicznych napięcia DM i CM dla ograniczania wytwarzanych przez nie prądów pasożytniczych: (DM) - międzyfazowych i (CM) – doziemnych. W wyniku badań osiągnięto prawie całkowitą eliminację pasożytniczego prądu upływu doziemnego z systemu ochrony przeciwporażeniowej PE.
Źródło:
Journal of Civil Engineering and Transport; 2019, 1, 1; 15-25
2658-1698
2658-2120
Pojawia się w:
Journal of Civil Engineering and Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency comparison between the LLCL and LCL-filters based single-phase grid-tied inverters
Autorzy:
Wu, W.
Huang, M.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/140537.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCL filter
LLCL-filter
efficiency power loss
modulation
single-phase grid-tied inverter
Opis:
An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 63-79
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural capacitor voltage balance in multilevel flying capacitor converters. A review of research achievements
Autorzy:
Stala, R.
Powiązania:
https://bibliotekanauki.pl/articles/1193250.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
flying capacitor converter
natural capacitor voltage balance
multilevel converter
inverter
DC-DC converter
Opis:
The flying-capacitor (FC) topology is one of the more well-established ideas of multilevel conversion, typically applied as an inverter. One of the biggest advantages of the FC converter is the ability to naturally balance capacitor voltage. When natural balancing occurs neither measurements, nor additional control is needed to maintain required capacitors voltage sharing. However, in order to achieve natural voltage balancing suitable conditions must be achieved such as the topology, number of levels, modulation strategy as well as impedance of the output circuitry. Nevertheless this method is effectively applied in various classes of the converter such as inverters, multicell DC-DC, switch-mode DC-DC, AC-AC, as well as rectifiers. The next important issue related to the natural balancing proces is its dynamics. Furthermore, in order to reinforce the balancing mechanism an auxiliary resonant balancing circuit is utilized in the converter which can also be critical in the AC-AC converters or switch mode DC-DC converters. This paper also presents an issue of choosing modulation strategy for the FC converter due to the fact that the natural balancing process is well-established for phase shifted PWM whilst other types of modulation can be more favorable for the power quality.
Źródło:
Power Electronics and Drives; 2016, 1, 36/2; 5-33
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel converter for voltage balance in series-connected capacitors and batteries
Autorzy:
Hachlowski, J.
Stala, R.
Powiązania:
https://bibliotekanauki.pl/articles/1193493.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
capacitor voltage balance
multilevel converter
NPC four-level inverter
voltage sharing
supercapacitor
battery
Opis:
This paper presents a novel concept of a circuit for voltage balance of three series-connected capacitors or batteries, as well as the research results. The problem is related to the control of voltage sharing on series capacitors, supercapacitors or battery banks in energy storage systems or direct current (DC)-link of four-level neutral-point-clamped inverters. The proposed circuit is a switched-capacitor (SC) resonant converter composed of a single capacitor and seven transistor switches. Control of the converter makes it possible to transfer energy between any capacitors, by switching selected transistors. This paper presents the basic concept of the converter, an analysis of control strategies and the simulation results for various cases of voltage balancing.
Źródło:
Power Electronics and Drives; 2018, 3, 38; 65-74
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of determining the COP coefficient for a cooling system
Sposób wyznaczenie współczynnika COP dla układu chłodniczego
Autorzy:
Rząsa, Mariusz
Pochwała, Sławomir
Szymaniec, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1841357.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
coefficient of performance
cooling system
inverter compressor
współczynnik COP
układ chłodniczy
sprężarka inwertorowa
Opis:
The basic metrological problem analyzed in this article is the experimental determination of the COP coefficient for arefrigerating system working in a stationary cooling chamber. This issue is because manufacturers of chillers provide the value of this coefficient in device technicaldata.In practice, after installing the refrigeration unit, the COP is often lower. The paper presents amethod of balancing cooling energy for a complete refrigeration system.
Podstawowym problemem metrologicznym, który autorzy pragną przedstawić jest eksperymentalne wyznaczenie współczynnika COP dla układu chłodniczego, pracującego w stacjonarnej komorze chłodniczej. Zagadnienie to jest istotne, ponieważ producenci agregatów chłodniczych najczęściej podają współczynnik COP dla agregatu chłodniczego. W praktyce po zamontowaniu agregatu chłodniczego w komorze chłodniczej współczynnik COP jest niejednokrotnie niższy. Trudność z wyznaczeniem współczynnika COP w układzie chłodniczym polega na koniczności zbilansowania mocy chłodniczej dla całego układu wraz z komorą chłodniczą. W pracy przedstawiono sposób bilansowania energii chłodniczej dla kompletnego układu chłodniczego oraz opisano budowę stanowiska do wyznaczania współczynnika COP.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2020, 10, 4; 69-72
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ laboratoryjny z wektorową przetwornicą częstotliwości
The laboratory unit with vector frequency inverter
Autorzy:
Siostrzonek, T.
Mondzik, A.
Powiązania:
https://bibliotekanauki.pl/articles/320194.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wektorowa przetwornica częstotliwości
silnik indukcyjny klatkowy
vector frequency inverter
squirrel cage induction motor
Opis:
W artykule przedstawiono wykonane w Laboratorium Elektroniki Przemysłowej stanowisko dydaktyczne układu napędowego z silnikiem indukcyjnym klatkowym zasilanym z wektorowej przetwornicy częstotliwości. Stanowisko powstało dzięki współpracy Katedr Automatyki Napędu i Urządzeń Przemysłowych z firmą Moeller Electric. Studenci mają więc możliwość zapoznania się z urządzeniami stosowanymi w zakładach przemysłowych. Badanie układu zostało wykonane przez studentów Koła Naukowego Elektroniki Przemysłowej pod nadzorem autorów.
This paper presents the laboratory unit with squirrel cage induction motor supplied by vector frequency inverter. This unit was made thanks to cooperation the Department of Electrical Drive and Industrial Equipment with Moeller Electric. The students have the possibility to know the industrial devices. The research was made by students under the direction of authors.
Źródło:
Elektrotechnika i Elektronika; 2005, 24, 1; 100-105
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The conception of the use of multi-level inverters in the shipping shaft generator systems of high power
Koncepcja wykorzystania falowników wielopoziomowych w układach z okrętową prądnicą wałową dużej mocy
Autorzy:
Tarnapowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/360407.pdf
Data publikacji:
2010
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
prądnica wałowa
stabilizacja częstotliwości
falownik wielopoziomowy
shaft generator
stability of frequency
multilevel inverter
Opis:
The fundamental problem of using the shaft generators of high power in the shipping systems is bound up with the stability of frequency. Electronic systems used nowadays are based on the thyristor inverters which entails vices of such solutions. The article presents the conception of the use of multi-level inverters built on the basis of fully controllable valves (transistors IGBT).This solution eliminates the defects of thyristor inverters.
Zasadniczy problem stosowania w systemach okrętowych prądnic wałowych dużej mocy związany jest ze stabilizacją częstotliwości. Stosowane obecnie układy energoelektroniczne opierają się na wykorzystaniu falowników tyrystorowych, które implikują wady takich rozwiązań. W artykule przedstawiono koncepcję wykorzystania falowników wielopoziomowych, zbudowanych w oparciu o zawory w pełni sterowalne (tranzystory IGBT), które pozbawione są wad falowników tyrystorowych.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2010, 22 (94); 67-70
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obserwator prędkości silnika asynchronicznego pracującego w układzie z filtrem sinusoidalnym
Speed control of asynchronous motor in system with output LC filter
Autorzy:
Guziński, J.
Powiązania:
https://bibliotekanauki.pl/articles/153952.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
falownik napięcia
filtr sinusoidalny
sterowanie wektorowe
voltage source inverter
LC filter
vector control
Opis:
W układach napędowych z tranzystorowymi falownikami napięcia występują niekorzystne zjawiska wynikające z dużych stromości napięć zasilających silnik. Aby ich uniknąć między falownik a silnik włącza się filtr bierny wygładzający przebiegi napięć i prądów silnika. Włączenie takiego filtru sinusoidalnego powoduje zmianę struktury układu i powoduje konieczność modyfikacji układu sterowania silnika i estymatorów zmiennych stanu układu. W niniejszym referacie przedstawiono układ napędowy w sterowaniu którego uwzględniono filtr sinusoidalny.
In the electric drives with voltage inverters appears disadvantageous phenomena come from high du/dt in motor supply voltage. To prevent that phenomena the passive filter is introduced between motor and inverter. Filter assure smoothed voltages and current in the electric motor. When the filter is used the structure of the system is changed so the control and estimation structure should be changed also. In the paper the modified electric drive with output LC filter is presented.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 27-31
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simple diagnostic technique of a single IGBT open-circuit faults for a SVM-VSI vector controlled induction motor drive
Autorzy:
Orlowska-Kowalska, T.
Sobański, P.
Powiązania:
https://bibliotekanauki.pl/articles/199993.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction motor
voltage inverter
IGBTs
fault diagnosis
silnik indukcyjny
przetwornica napięcia
błąd diagnostyczny
Opis:
In this paper a simple diagnostic system for a single IGBT open-circuit faults for a two level voltage inverter-fed field oriented controlled induction motor drive was presented. A fault diagnostic procedure is carried out by utilizing an analysis of a stator current vector trajectory in α-β coordinates. An extraction of the failure information is based on monitoring of an angle between the stator current space vector and the axis. Thanks to a diagnostic signal normalization, high robustness to false diagnosis alarms is guaranteed. To confirm the proposed method, simulation results under a wide range working condition of the induction motor drive were presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 1; 281-288
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Induction motor diagnosis with use of electric parameters
Diagnostyka silnika indukcyjnego z wykorzystaniem parametrów elektrycznych
Autorzy:
Roczek, Krzysztof
Rogala, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/328551.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
induction motor
MCSA
current spectrum
frequency inverter
silnik indukcyjny
widmo prądu
przemiennik częstotliwości
Opis:
Induction motors are very commonly used in industry. From that reason more and more often different methods of induction motor diagnosis are applied. In this article motor current signature analysis (MCSA) method is presented with special Extended Park’s Vectors Approach. This method extends the possibility of current signals analysis in frequency domain giving better recognition of some faults. In the presented experiment few malfunctions were applied to the laboratory stand which consists of two different induction motors. In both cases they were supplied from frequency inverter, therefore additionally influence of this type of control on current spectrum is presented. The results of presented research and gathered experience in this domain are the basis for the elaboration of advanced on-line diagnostic system for industrial object.
Silniki indukcyjne są powszechnie używane w przemyśle. Z tego powodu coraz częściej stosowane są różne metody ich diagnozowania. W niniejszym artykule zostały zeprezentowane metody MCSA z wykorzystaniem zastosowania podejścia EPVA (Extended Park’s Vector Approach). Metoda ta daje bardzo dobre możliwości diagnostyczne przy wzroście czułości systemu oraz jego niezawodności. W opisanym poniżej doświadczeniu zaimplementowano do układu kilka uszkodzeń. System składał się z dwóch typów silników, które były zasilone i sterowane za pomocą przemiennika częstotliwości. W doświadczeniu wyeksponowano również wpływ przemiennika częstotliwości na widmo prądowe silnika. Przedstawione wyniki badań i zdobyte w trakcie ich wykonywania doświadczenie stanowią podstawę do opracowania systemu diagnostycznego działającego w czasie rzeczywistym dla obiektu przemysłowego.
Źródło:
Diagnostyka; 2019, 20, 4; 65-74
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design, development and verification of a new multilevel inverter for reduced power switches
Autorzy:
Mahato, Bidyut
Ranjan, Mrinal
Pal, Pradipta Kumar
Gupta, Santosh Kumar
Mahto, Kailash Mahto
Powiązania:
https://bibliotekanauki.pl/articles/2172807.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
7-level/13-level inverter
DC-AC converters
power-electronic switches
sinusoidal PWM
Opis:
Due to recent developments in the field of high-power and medium-voltage, the multilevel inverter has raised to such an extent owing to some of its amazing facts regarding harmonic spectrum, ease in control, reduced electromagnetic interference (EMI), filterless circuit, stress on power switches, common-mode voltage. This paper well describes a novel architecture of a single-phase multilevel inverter using a lesser number of overall components, especially the power switches. The proposed topology is generalized in the structure that can generate any number of voltage steps. A 7-level structure of the proposed topology is explained and is elaborately discussed. Simulation is carried out in MATLAB and corresponding experimental results verify the existence of the proposed multilevel inverter. The real-time experimental results were presented and are well verified by the simulation results for 7-level as well for 13-level across RL-Load. The nature of load current is also indicated as per the nature of load voltage. Nevertheless, the topology is further compared with some of the recent literature and found superior in each respect.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 1051--1063
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane aspekty zaburzeń generowanych przez przemienniki częstotliwości
Selected aspects of disturbances generated by converters
Autorzy:
Szkółka, S.
Wiśniewski, G.
Strama, P.
Powiązania:
https://bibliotekanauki.pl/articles/186424.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
falownik PWM 1,5 kW
zasilanie silnika
engine fuelling
PWM inverter 1.5 kW
Opis:
W artykule przedstawiono i omówiono różne sposoby zasilania silnika poprzez falownik. Zaprezentowano ponadto wyniki pierwszego etapu badań falownika PWM o mocy 1,5 kW przy różnych konfiguracjach jego układu zasilania.
The article features different methods of providing power supply to an engine through an inverter. Additionally, the article presents the results of the first phase of tests on a PWM inverter with the power of 1.5 kW at different configurations of its power supply system.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2010, R. 48, nr 7, 7; 60-68
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesne silniki asynchroniczne zintegrowane z energoelektronicznymi układami napędowymi - właściwości eksploatacyjne zastosowanych układów napędowych
Modern asynchronous motors integrated with power electronic drive systems - exploitation properties of applied drive systems
Autorzy:
Przybyłka, Jacek
Kuzera, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1196885.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
maszyny elektryczne
przemiennik częstotliwości
soft-start
nagrzewanie wirnika
electrical machines
frequency inverter
rotor heating
Opis:
Induction cage motors are widely used in industry for drives of all types of equipment and machines. In the era of the development of automatic drive control and visualization systems, they require appropriate power electronic systems to significantly increase their control capabilities. The article presents the requirements for motors integrated with power electronics systems based on the results of tests carried out on a soft-start motor in comparison with inverter power supply. Presented is the possibility of working in automatic mode with the visualization of the drive.
Silniki indukcyjne klatkowe są powszechnie stosowane w przemyśle do napędów wszelkiego rodzaju maszyn i urządzeń. W dobie rozwoju automatycznych układów sterowania i wizualizacji napędów, wymagają one do zasilania odpowiednich układów energoelektronicznych znacząco zwiększających ich możliwości regulacyjne. W artykule przedstawiono wymagania stawiane silnikom zintegrowanym z układami energoelektronicznymi w oparciu o wyniki badań silnika zasilanego z soft-startu w porównaniu z zasilaniem falownikowym. Zaprezentowano także możliwości pracy silników w trybie automatycznym z wizualizacją pracy napędów.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 1, 121; 19-25
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current limiting algorithm for three-phase grid-connected inverters
Autorzy:
Tran, Tho Quang
Powiązania:
https://bibliotekanauki.pl/articles/2135740.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current limitation
negative sequences
reactive power compensation
three-phase grid-connected inverter
unbalanced voltages
Opis:
Grid-connected inverters are commonly used in systems of renewable energy to convert this energy source into AC power with parameters suitable for connection to the grid. In the normal operating conditions, the grid-connected inverters mainly generate active power to the grid. However, when a voltage sag or voltage imbalance occurs, the grid voltage imbalance in the conventional control methods causes negative sequence components and increases the output current magnitude of inverters. The increase of current can damage power semiconductor devices. This paper presents a strategy to limit the current magnitude of inverters under unbalanced grid voltage conditions. In this strategy, a multiple-complex-coefficient filter is used to eliminate the negative sequence voltage components. This method does not require any additional hardware. A three-phase gridconnected photovoltaic inverter system using a solar array of 20 kWp is also used for the survey. The effectiveness has been validated when comparing the simulation results on Matlab/Simulink of the proposed method with those of the conventional method.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 559--579
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel circuit topology of modified switched boost hybrid resonant inverter fitted induction heating equipment
Autorzy:
Bhattacharya, A.
Sit, K.
Sadhu, P. K.
Pal, N.
Powiązania:
https://bibliotekanauki.pl/articles/140770.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modified switched boost
high frequency
hybrid resonant inverter
induction heating
controllability
VSI and PSIM
Opis:
A novel circuit topology of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment is presented in this paper for efficient induction heating. Recently, induction heating technique is becoming very popular for both domestic and industrial purposes because of its high energy efficiency and controllability. Generally in induction heating, a high frequency alternating magnetic field is required to induce the eddy currents in the work piece. High frequency resonant inverters are incorporated in induction heating equipment which produce a high frequency alternating magnetic field surrounding the coil. Previously this high frequency alternating magnetic field was produced by voltage source inverters. But VSIs have several demerits. So, in this paper, a new scheme of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment has been depicted which enhances the energy efficiency and controllability and the same is validated by PSIM.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 815-826
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-phase voltage outages kompensator with cascaded multilevel converter
Autorzy:
Iwaszkiewicz, J.
Bogusławski, P.
Krahel, A.
Łowiec, E.
Powiązania:
https://bibliotekanauki.pl/articles/141242.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
superkondensator
spadki napięcia
wielopoziomowy falownik
synchronizacja
supercapacitor
voltage dips and sags
multilevel inverter
synchronization
Opis:
The paper presents a laboratory prototype of the three-phase transformer less voltage outages compensator with an energy storage based on high voltage supercapacitors. The system described is able to protect an isolated grid e.g. in industry against short voltage interruptions, dips and sags. An idea of a control method as well as a Digital controller has been presented, too.
Źródło:
Archives of Electrical Engineering; 2012, 61, 3; 325-336
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Feedback control of three-Level PWM rectifier: Application to the stabilization of DC Voltages of five-level NPC active power filter
Autorzy:
Abdelkrim, T.
Berkouk, E. M.
Benslimane, T.
Benamrane, K.
Powiązania:
https://bibliotekanauki.pl/articles/229851.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
NPC multilevel inverter
feedback control
PWM current rectifier
clamping bridge filter
Opis:
One of the most important drawbacks of the three phases five-level NPC (Neutral Point Clamped) Active Power Filter (APF) is the neutral point balance. As the consequence, the capacitors voltages of the input DC bus of the APF are not equal which constitutes the major limitation for the use of this power converter. In order to stabilize these DC voltages, it is proposed in this paper to study the cascade constituted by three phases three-level PWM rectifier-clamping bridge filter-five-level NPC APF. In the first part, the authors present a topology of five-level NPC Voltage Source Inverter (VSI), and then, they propose a model of this converter and its PWM control strategy. In the second part, the modeling and control of three-level PWM current rectifier is presented. In the third part, to remedy to instability problem of the input capacitors DC voltages of the APF, the authors propose feedback control of the three-level PWM rectifier followed by clamping bridge filter. After that, the sliding mode regulator used to control the active filter is developed. The obtained results are full of promise to use this topology of APF in high voltage and high power applications.
Źródło:
Archives of Control Sciences; 2010, 20, 3; 317-339
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Falownik trójfazowy ze zmiennym algorytmem sterowania
Three-phase inverter with variable control algorithm
Autorzy:
Szerszeń, Grzegorz
Zygadło, Damian
Powiązania:
https://bibliotekanauki.pl/articles/2086188.pdf
Data publikacji:
2021
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
przemiennik częstotliwości
falownik
modulacja PWM
sterowanie skalarne
frequency converter
inverter
PWM modulation
scalar control
Opis:
Wpracyprzedstawionobudowę trójfazowegoprzemiennika częstotliwości zmożliwościąwyboru typu modulacji PWM oraz płynną zmianą częstotliwości sygnału modulowanego.Wpraktyczny sposób zrealizowano różne algorytmy sterowania falownikaw tymsamymukładzie sprzętowym zwykorzystaniemprocesora STMARMCortexM3. ZastosowaniemodulacjiTHIPWMpozwoliło zmniejszyć zawartośćharmonicznychw sygnalewyjściowymi efektywniewykorzystaćmożliwości źródła zasilania. Układ posiada możliwość wyboru jednego z dwóch algorytmów sterowania skalarnego, z opcją kompensacji wpływu rezystancji stojana na moment obrotowy wału silnika w początkowym zakresie charakterystyki sterowania liniowego przy stałym stosunku napięcia do częstotliwości. Badania potwierdziły, że najkorzystniejszym typem modulacji PWM w tym układzie jest modulacja jednobiegunowa dwubrzegowa.Wykorzystanie metodyTHIPWM, skutkowało zyskiem amplitudy podstawowej harmonicznej napięcia wyjściowego dla trójfazowego trybu pracy falownika względem metody SPWM. Uzyskano także odpowiednią precyzję kroku regulacji częstotliwości, a rezultaty badań potwierdziły funkcjonalność przemiennika.
The paper presents the construction of a three-phase frequency converter with the possibility of choosing the type of PWM modulation and a smooth change of the frequency of the modulated signal. In a practical way, various inverter control algorithms were implemented in the same hardware system using the STM ARM Cortex M3 processor. The use of THIPWM modulation allowed to reduce the harmonic content in the output signal and effectively use the possibilities of the power source. The system can choose one of two scalar control algorithms, with the option of compensation for the influence of the stator resistance on the motor shaft torque in the initial range of the linear control characteristic at a constant voltage to frequency ratio. The research confirmed that the most advantageous type of PWM in this system is unipolar double-edge modulation. The use of the THIPWM method resulted in a gain in the amplitude of the fundamental harmonic of the output voltage for the three-phase inverter operation mode compared to the SPWM method. The appropriate precision of the frequency control step was also obtained, and the test results confirmed the functionality of the converter.
Źródło:
Science, Technology and Innovation; 2021, 14, 3; 1--11
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies