Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Inverter" wg kryterium: Temat


Tytuł:
Three-phase soft-switching inverter with coupled inductors, experimental results
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/200045.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant inverter
ZVS inverter
Opis:
This paper presents experimental results of the three-phase soft-switching inverter with coupled inductors that verify the control method influence on efficiency improvement. Different kinds of control methods were tested on the 6 kW experimental inverter. A short discussion on a few design methods of the resonant tank elements was made. Experimental results confirm that the advanced control algorithm and the proposed new design method of the resonant tank elements significantly increase the efficiency of this resonant inverter.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 535-540
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extended T-type inverter
Autorzy:
Rąbkowski, J.
Kopacz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1193496.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
T-type inverter
boost converter
silicon carbide
Opis:
This paper presents a new concept for a power electronic converter – the extended T-type (eT) inverter, which is a combination of a three-phase inverter and a three-level direct current (dc)/dc converter. The novel converter shows better performance than a comparable system composed of two converters: a T-type inverter and a boost converter. At first, the three-level dc/dc converter is able to boost the input voltage but also affects the neutral point potential. The operation principles of the eT inverter are explained and a simulation study of the SiC-based 6 kVA system is presented in this paper. Presented results show a serious reduction of the DC-link capacitors and the input inductor. Furthermore, suitable SiC power semiconductor devices are selected and power losses are estimated using Saber software in reference to a comparative T-type inverter. According to the simulations, the 50 kHz/6 kVA inverter feed from the low voltage (250 V) shows <2.5% of power losses in the suggested SiC metal oxide–semiconductor field-effect transistors (MOSFETs) and Schottky diodes. Finally, a 6 kVA laboratory model was designed, built and tested. Conducted measurements show that despite low capacitance (2 × 30 μF/450 V), the neutral point potential is balanced, and the observed efficiency of the inverter is around 96%.
Źródło:
Power Electronics and Drives; 2018, 3, 38; 55-64
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie falowników rezonansowych w przemyśle elektromaszynowym i wydobywczym
Application of resonance inverters in the electric machine and mining industry
Autorzy:
Marek, A.
Powiązania:
https://bibliotekanauki.pl/articles/186005.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
falownik L-LC
falownik rezonansowy
inverter L-LC
resonance inverter
Opis:
Celem artykułu jest przedstawienie i omówienie najczęściej stosowanych układów zasilających nagrzewnice indukcyjne, ich właściwości oraz porównanie ich z proponowanym rozwiązaniem w postaci falownika L-LC.
The paper aims at a presentation and a discussion on the mostly used power supply systems for induction heaters, their characteristics and comparison to a suggested system in the form of an inverter L-LC.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2009, R. 47, nr 2, 2; 17-22
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental results of parallel connected inverters feeding medium voltage transformer
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/377860.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical transformer
line side inverter
inrush currents
inverter parallel operation
Opis:
Development of medium voltage, high power ship electrical installations on board of special purpose vessels, has led to use of grid side inverters along with step-up grid transformers. In this paper there is presented theoretical background and experimental results of two inverters in parallel connection feeding one 0,4/15 kV transformer.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 359-368
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja wydajności urządzeń potrzeb własnych elektrowni cieplnych asynchronicznymi napędami falownikowymi średniego napięcia
Variable speed drives with frequency converters in thermal power plant auxiliaries
Autorzy:
Wawszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/173004.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia cieplna
napęd falownikowy
przemiennik
thermal power station
inverter drive
inverter
Opis:
Omówiono możliwości regulacji wydajności urządzeń potrzeb własnych elektrowni cieplnych napędzanych klatkowymi silnikami indukcyjnymi zasilanymi przemiennikami częstotliwości. Skupiono się głównie na napędach średnionapięciowych (6÷10 kV) dużej mocy. Przedstawiono aktualną ofertę przemienników czołowych światowych producentów. Oceniono możliwości wykorzystania tego typu napędów w dużych, nowoczesnych elektrowniach blokowych.
The paper introduces current potential of variable speed drives (VSD) intended for squirrel cage induction motors supplied by frequency converters in thermal power plant auxiliaries. The paper is mostly focused on medium-voltage (6-10 kV) and high-power drives. Current tender of leading world producers in this field has been presented. Possibility to apply this type of drives in large, modern block-power plants has been considered.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 87-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adjusting output impedance using a PI controller to improve the stability of a single-phase inverter under weak grid
Autorzy:
Jiao, J.
Nelms, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/136224.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
grid impedance
inverter output impedance
LC filter
PI controller
single-phase inverter
Opis:
Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 50-57
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Z-source converter in photovoltaic grid-connected transformer-less inverter
Autorzy:
Farhangi, B.
Farhangi, S.
Powiązania:
https://bibliotekanauki.pl/articles/262715.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
photovoltaic power conditioner (PV PCU)
gird-connected systems
Z-source inverter
inverter
Opis:
In PV grid connected power conditioners, usually both stepping-up the PV array voltage, and stepping-down the dc bus voltage for injection of a sinusoidal current to the grid is required. In this paper the design procedure of Z-source converter as a single phase PV grid connected transformer-less inverter is presented. The converter has one switch less than the conventional two stage power conditioner, which leads to reduction of cost. An optimum modulation pattern for the switches is proposed, and the low frequency ripple of the converter is modeled. The design of the converter is verified by simulation.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 41-45
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single-source three-phase switched-capacitor-based MLI
Autorzy:
Jena, Kasinath
Gupta, Krishna Kumar
Bhatnagar, Pallavee
Jain, Sanjay K.
Stala, Robert
Waradzyn, Zbigniew
Piróg, Stanisław
Penczek, Adam
Mondzik, Andrzej
Skała, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/2175942.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
switched capacitor
multicarrier pulse width modulation
cost function
ANPC inverter
Opis:
This article proposes a novel three-phase inverter based on the concept of switched capacitors (SCs), which uses a single DC source. A three-phase, seven-level line-to-line output voltage waveform is synthesised by the proposed topology, which includes eight switches, two capacitors, and one diode per phase leg. The proposed topology offers advantages in terms of inherent voltage gain, lower voltage stresses on power switches, and a reduced number of switching components. Additionally, the switched capacitors are self-balanced, thereby eliminating the need for a separate balancing circuit. The proposed structure and its operating principle, the self-balancing mechanism of the capacitors, and the control strategy are all thoroughly explained in the article. The proposed topology has also been compared with some recent SC topologies. Lastly, the proposed topology has been shown to be feasible through simulation and experimentation.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 197--209
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GaN-based soft-switched active power buffer operating at ZCS – problems of start-up and shut-down
Autorzy:
Rąbkowski, J.
Król, K.
Zdanowski, M.
Sochacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/201868.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
GaN
power inverter
active buffer
Opis:
This paper describes practical issues related to control of the active power buffer (APB) developed for a 2 kVA single-phase inverter. The buffer is designed using the latest GaN HEMTs controlled with triangular current mode to reduce switching losses, however, the switching frequency should be limited to 1 MHz. In the case of the presented analogue-digital controller, frequency is influenced by a reference current of the APB and circuit. Therefore, the operation at start-up and shut-down is especially challenging. A modified control algorithm that also includes pre-charging and discharging process of the energy buffer is presented and experimentally verified by series of tests of the 2 kVA GaN based inverter with the APB.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 785-792
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault Diagnosis of Sensors for T-type Three-Level Inverter-fed Dual Three-Phase Permanent Magnet Synchronous Motor Drives
Autorzy:
Wang, Xueqing
Wang, Zheng
Wang, Wei
Cheng, Ming
Powiązania:
https://bibliotekanauki.pl/articles/1193713.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fault diagnosis
sensor fault
T-type inverter
three-level inverter
dual
three-phase
PMSM
Opis:
To improve the reliability of motor system, this paper investigates the sensor fault diagnosis methods for T-type inverter-fed dual three-phase permanent magnet synchronous motor (PMSM) drives. Generally, a T-type three-level inverter-fed dual three-phase motor drive utilizes four phase-current sensors, two direct current (DC)-link voltage sensors and one speed sensor. A series of diagnostic methods have been comprehensively proposed for the three types of sensor faults. Both the sudden error change and gradual error change of sensor faults are considered. Firstly, the diagnosis of speed sensor fault was achieved by monitoring the error between the rotating speed of stator flux and the value from speed sensor. Secondly, the large high-frequency voltage ripple of voltage difference between the estimated voltage and the reference voltage was used to identify the voltage sensor faults, and the faulty voltage sensor was determined according to the deviation of voltage difference. Thirdly, the abnormal current amplitude on harmonic subspace was adopted to identify the current sensor faults, and the faulty current sensor was located by distinguishing the current trajectory on harmonic subspace. The experiments have been taken on a laboratory prototype to verify the effectiveness of the proposed fault diagnosis schemes.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 165-176
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiphase Z-source inverter using maximum constant boost control
Autorzy:
Kouzou, A.
Abu-Rub, H.
Powiązania:
https://bibliotekanauki.pl/articles/229291.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Z-source inverter
multiphase inverter
five phase machine
shoot-through
boost factor
duty cycle
Opis:
This paper deals with the impedance source (Z-source) multiphase inverter, where the maximum constant boost control method is studied and analyzed in the general case of number of phases. On the other side the impact of the modulation index and the number of phases on the duty cycle shoot-through and on the gain of the output voltage ranges is presented. To validate advantages of the Z-source multiphase inverter, the proposed topology and the maximum constant boost control are implemented in simulation and in real time experimentation with Z-source five phase inverter. The output voltage is applied to two parallel loads, a five phase resistive load and a five phase induction machine.
Źródło:
Archives of Control Sciences; 2013, 23, 1; 107-126
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency control of inverter fed induction motor drives
Autorzy:
Shaban, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/376136.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
induction motor
torque-speed characteristic
inverter
Opis:
Induction motor losses at partial loads can be significantly reduced by operating an adjustable frequency drive at the optimum slip which yields maximum efficiency. The present investigation quantifies the potential improvement in induction motor efficiency for both standard and energy efficient motors operating on a six-step voltage-source inverter supply. The analysis employs a comprehensive model of the induction motor which incorporates the frequency - dependent nature of the motor parameters and effects of stray load loss. Efficiency contours are plotted on a torque- speed plane for constant volts/hertz operation and for optimum slip frequency control plotted as a contour map.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 72; 291-295
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified Topology and Modulation Technique for Z-Source Neutral-Point Clamped Inverter
Autorzy:
Akbari, Ehsan
Zishan, Farhad
Powiązania:
https://bibliotekanauki.pl/articles/2175930.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
modulation
optimization
multilevel inverter
MZS-NPC
Opis:
The impedance network makes it possible to increase and decrease the voltage, which is not available in normal inverters (voltage and current sources).This paper presents a modified topology and modulation technique for a three-phase Modified Z-Source Neutral-Point Clamped (MZS-NPC) inverter. A modulation scheme for the proposed topology is designed based on maximum gain control method to achieve the maximum voltage gain by simple implementation and balancing the neutral point voltage of the dc link. In order to supply the desired voltage to the critical load in an islanded micro-grid, a closed-loop ac voltage controller is realized in fuel cell or photovoltaic applications based on the proposed inverter. The ability to reinforce and validity of topology operations and modulation techniques has been demonstrated by simulation. It should be noted that the simulations are implemented in MATLAB / Simulink software.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 210--226
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
Autorzy:
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201199.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronous machine
DC/AC inverter
DTC
flux and torque control
3-level DC/AC inverter
Opis:
This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 771-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odzyskiwanie energii elektrycznej w aplikacjach napędowych z falownikami Danfoss Drives
Autorzy:
Ptaszyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/304909.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
falownik
energia elektryczna
hamowanie
inverter
electricity
braking
Opis:
W artykule przygotowanym przez firmę Schulz Infoprod, która od wielu lat jako Autoryzowany Dystrybutor współpracuje z Danfoss, przedstawiono rozwiązania kontroli energii oddawanej przez napęd w trakcie dynamicznego hamowania.
Źródło:
Napędy i Sterowanie; 2017, 19, 3; 28-30
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamiczna regulacja mocą przekształtników sieciowych
Dynamic power control of the grid converters
Autorzy:
Zieliński, D.
Powiązania:
https://bibliotekanauki.pl/articles/407678.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
przekształtnik
VOC
LVRT
Simulink
inverter
PI algorithm
Opis:
Dynamicznie rozwijający się sektor źródeł odnawialnych zmusza urząd regulacji energetycznej do wprowadzania coraz bardziej rygorystycznych norm odnośnie jakości dostarczanej energii i dynamiki samych źródeł. W przyszłości przepisy będą wymagały by źródło energii odnawialnej własnościami dynamicznymi przypominało generator synchroniczny o równoważnej mocy. Ponadto źródło powinno własności tłumienia oscylacji mocy w systemie elektroenergetycznym i powinno wspomagać sieć w odbudowie napięcia. Powyższe przyczyny implikują sterowanie nieliniowe wysokiej dynamiki układów pośredniczących pomiędzy źródłem a siecią jakim są przekształtniki. Artykuł prezentuje regulator nieliniowy poprawiający dynamikę sterowania mocą w układach przekształtników wektorowych. Analizę dokonano za pomocą oprogramowania Matlab/SIMULINK.
The dynamic growth of the renewable energy sources sector causes that the Energy Regulatory Office introduces stricter and stricter grid codes about quality of the energy and dynamics of the sources. In the future, grid codes will require that the dynamic properties of the renewable source of energy is similar to the synchronous generator with the same power. Moreover, the renewable source of energy should damp power oscillation in power grid, and support it to stabilize the voltage. These causes lead us to use a high dynamic nonlinear control system – converters, installed between a source and a power grid. The paper presents a nonlinear controller improves the dynamic power control of the vector inverters’ systems. The analysis was made by using the MATLAB/Simulink software.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 1; 59-62
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of harmonic voltage coupling on torque ripple of permanent magnet synchronous motor
Autorzy:
Geng, Shengtao
Zhang, Yong
Qiu, Hongbo
Yang, Cunxiang
Yi, Ran
Powiązania:
https://bibliotekanauki.pl/articles/140572.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PMSM
harmonic voltage coupling
torque ripple
inverter
Opis:
The permanent magnet synchronous motor (PMSM) driven by an inverter is widely used in the industrial field, but the inverter has a significant impact on the operational stability of the PMSM. The torque ripple of the PMSM is directly affected by the coupling of multiple harmonic voltages in the motor windings. In order to analyze its influence, a water-cooled PMSM with 20 kW 2000 r/min is taken as an example to establish the finite element model of the prototype, and the correctness of the model is verified by experiments. Firstly, based on the finite element method, the electromagnetic field of the PMSM is numerically solved in different operating states, and the performance parameters of the PMSM are obtained. Based on these parameters, the influence of the harmonic voltage amplitude on the torque ripple is studied, and the influence law is obtained. Secondly, combined with the decoupling analysis method, the influence of harmonic voltage coupling on the torque ripple is compared and analyzed, and the variation law of harmonic voltage coupling on the torque ripple is obtained. In addition, the influence of different harmonic voltage coupling on the average torque of the PMSM is studied, and the influence degree of different harmonic voltage amplitude on the torque fluctuation is determined. The conclusion of this paper provides reliable theoretical guidance for improving motor performance.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 399-410
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel in-phase disposition SPWM pulse allocation strategy for cascaded H-bridge inverter
Autorzy:
Zhang, Y.
Xiong, J.
Kong, L.
Wang, X.
Powiązania:
https://bibliotekanauki.pl/articles/141155.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
in-phase disposition SPWM
Inverter
CHB
THD
Opis:
A novel in-phase disposition (IPD) SPWM pulse allocation strategy applied to a cascaded H-bridge (CHB) converter is presented in this paper. The reason causing the power of the CHB converter imbalance is analyzed according to the traditional structure, the conception of power imbalance degree is introduced and the principle of the novel in-phase disposition SPWM allocation strategy is deduced in detail. The new pulse allocation scheme can ensure the power balance in 3/4 cycles through interchanging the PWM pulse sequence of the different CHB cell, meanwhile it makes the full advantage of the IPD control strategy, lower the total harmonic distortion (THD) of line voltage compared to a carrier phase shifted (CPS) control strategy, which is verified by theoretical derivation. A seven-level cascaded inverter composed by three H-bridge cells is taken as the example. The simulation and experiment is performed. The results indicate the validity of the analysis and verify the effectiveness of the proposed SPWM allocation strategy.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 361--375
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of 5 kW Converter Leg for Power Electronic System
Autorzy:
Zygmanowski, M.
Michalak, J.
Jeleń, M.
Jarek, G.
Powiązania:
https://bibliotekanauki.pl/articles/973060.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IGBT
Silicon Carbide (SiC)
MOSFET
Inverter
Microgrid
Opis:
Three converter leg variants are analyzed for low power converter used for power electronic system for residential buildings. The two-level Si-IGBT and SiC-MOSFET converters are compared with Si-IGBT three-level T-type converter. Power losses generated in each of these converters over a predicted period of 20 years of operation are contrasted with the cost of converter options. The detailed selection procedure for output inductor is presented in this paper. This procedure shows the influence of the inductor parameters like number of turns, air gap length on its losses, cost and size. Theoretical approach is verified with simulations and experimental results.
Źródło:
Measurement Automation Monitoring; 2017, 63, 8; 282-287
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Passive filter design for three-phase inverter interfacing in distributed generation
Autorzy:
Ahmed, K. H.
Finney, S. J.
Williams, B. W.
Powiązania:
https://bibliotekanauki.pl/articles/262578.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
DG
inverter
grid connected
filtering
damping
harmonics
Opis:
With the growing use of inverters in distributed generation, the problem of injected harmonics becomes critical. These harmonics require the connection of low pass filters between the inverter and the network. This paper presents a design method for the output LC filter in grid coupled applications in distributed generation systems. The design is according to the harmonics standards that determine the level of current harmonics injected into the grid network. Analytical expressions for the maximum inductor ripple current are derived. The filter capacitor design depends on the allowable level of switching components injected into the grid. Different passive filter damping techniques to suppress resonance affects are investigated and evaluated. Simulated results are included to verify the derived expressions.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 49-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-level modulation techniques to reduce instantaneous common mode voltage in induction machines
Autorzy:
Cusidó, J.
Luna, A.
Busquets, S.
Bordonau, J.
Rodríguez, P.
Romeral, L.
Powiązania:
https://bibliotekanauki.pl/articles/262817.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
common mode voltages
multilevel inverter
drive systems
Opis:
Problems on inverter motor drives such as bearing currents are introduced due to common mode voltages. Different solutions are proposed on literature, for two-level or multilevel inverter. Instantaneous zero common mode voltage by using a three-level inverted could be achieved. This paper proposes a commutation strategy that allows zero common mode voltage by using medium vectors, and also a new representation as a plane on the commutation space is defined which is called zero common mode voltage plane. On this defined plane, every turning vector fulfil this property. Simulations and experimental results clearly show method's efficiency.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 33-38
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PQ Cootrol of Photovoltaic Power Statioo in Microgrid Operation
Autorzy:
Cygan, S.
Łukowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/410543.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
inverter PQ control
PowerSys microgrid model
microgird control
Opis:
The numerical modelling of the photovoltaic module and the solar inverter interconnected with the microgrid has been carried out with the use of PowerSys in Matlab/Simulink. Algorithms of P, Q controllers have been proposed. The capability of the active and reactive power reference tracking has been tested for various conditions.
Źródło:
Present Problems of Power System Control; 2017, 8; 51-59
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical method of a calculation of a torque ripple of a two-phase asynchronous motor supplied by a pwm controlled inverter
Metoda analityczna obliczania pulsacji momentu dwufazowego silnika asynchronicznego zasilanego z falownika PWM
Autorzy:
Záskalický, P.
Powiązania:
https://bibliotekanauki.pl/articles/1368690.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
asynchronous motor
PWM controlled inverter
modeling
analytical method
Opis:
The paper deals with steady state calculation of torque and currents ripples of a two-phase asynchronous machine, which is supplied by an IGBT transistors half-bridge connected inverter. The inwerter output voltage is controlled by a PWM of the input DC voltage. The complex Fourier series analysis of the inverter output voltage was made, to obtain a spectrum of the harmonic supply voltages. The different voltage harmonic was applied to the two-phase induction machine model to obtain the electromagnetic torque and currents waveforms for various operation conditions.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 131-135
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
Autorzy:
Turzyński, M.
Banach, P.
Murawski, P.
Pepliński, R.
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200484.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resonant converters
ZVS three-phase inverter
current estimation
Opis:
Control of parallel quasi resonant dc link inverters (PQRDCLI) is usually based on dc link input inverter current. Instead of a direct measurement of this noise sensitive and fast changing current signal - its estimation with one step prediction may be considered. Estimation of an input inverter current is based on inverter output current measurements, applied in most of power electronics controlled ac drives. In this paper, the PQRDCLI fed induction motor (IM) with a predictive current estimation stabilizes resonant inverter output voltage slopes du/dt independently of load. By control of output voltage derivatives, reduction of overvoltage spikes and common mode motor currents is achieved. An analysis of the PQRDCLI control with a predictive current estimation strategy is verified by the Saber system simulation and experimental tests in a laboratory setup.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 757-762
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Falowniki trakcyjne kolejowych pojazdów szynowych – rozwiązania techniczne i kierunki rozwoju konstrukcji
Static converters of railway vehicles - technical solutions and directions of construction development
Autorzy:
Biliński, Janusz
Malczewska, Marta
Rojek, Artur
Kruczek, Włodzimierz
Powiązania:
https://bibliotekanauki.pl/articles/253989.pdf
Data publikacji:
2020
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
pojazdy kolejowe
falownik trakcyjny
railway vehicles
traction inverter
Opis:
Nowoczesna technologia i ciągły rozwój na rynku komponentów elektronicznych pozwala na tworzenie bardziej energooszczędnych, lżejszych, cichszych i mniejszych systemów trakcyjnych [1]. W artykule przedstawione zostały różne systemy trakcyjne wraz z ich parametrami zależnymi od architektury pojazdu. Architektura pojazdu ściśle wiąże się z napięciem sieci trakcyjnej oraz typem przejazdów realizowanych przez te pojazdy (miejskie, regionalne, szybkie, towarowe) [2].
Innovative technology and continuous development of the electronic components industry enables creation of components of higher energy-efficiency, lighter, quieter and even smaller traction systems [1]. The article presents different traction systems with their parameters which are highly depend on the vehicle architecture. The vehicle architecture is strongly related to the catenary line voltage and type of service provided by vehicles (urban, regional, fast, cargo) [2].
Źródło:
TTS Technika Transportu Szynowego; 2020, 5-6; 43-57
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalne sterowanie falownika przy jego pracy na sieć systemu energetycznego
Optimal inverter controling during its operation for power grid
Autorzy:
Mazur, D.
Powiązania:
https://bibliotekanauki.pl/articles/1369606.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
optymalne sterowanie
system energetyczny
optimal inverter
power grid
Opis:
The inverter circuit is supposed to operate for grid with low internal impedance (for fixed grid). The goal of the presented circuit is to provide the given current of the main harmonic to the grid. The grid can contain higher harmonics of the voltage, which due to the low impedance of the grid lines spreads to the voltage of the inverter output. Therefore we need to calculate the first (main) harmonic of this voltage and find such inverter controlling, that the main harmonic of the current flowing to the grid from the considered circuit would be in the given angle position to it and at the given value. The second important goal of the circuit is, as far as possible, to eliminate the voltage higher harmonics at the circuit output getting there from the grid. Obviously eliminating the ripples from voltage higher harmonics of the receiver is limited by the capabilities of the examined inverter circuit.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 2, 95; 25-30
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona układu izolacyjnego transformatora współpracującego z falownikami
Protection of the transformer insulation system cooperating with inverters
Autorzy:
Bernatt, Jakub
Gawron, Stanisław
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2142529.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
falownik
kondensator
warystor
transformer
inverter
capacitor
varistor
Opis:
Farmy fotowoltaiczne są łączone z siecią elektroenergetyczną poprzez falownik DC/AC i transformator. Komutacja prądu w zaworach falownika generuje w indukcyjnościach rozproszenia impulsy napięcia, które oddziałują na układ izolacyjny uzwojeń transformatora. Skuteczną ochronę izolacji uzwojeń transformatora przed przepięcia stanowią filtry tłumiące. Mogą to być kondensatory bądź warystory. Filtr w sposób znaczący poprawia warunki dielektryczne izolacji uzwojenia transformatora.
The solar farms are connected to the electricity grid through a DC / AC inverter and a transformer. The current commutation in the inverter valves generates voltage pulses in the leakage inductances, which act on the insulation system of the transformer windings. Suppression filters provide effective protection of the transformer winding insulation against overvoltage. These can be capacitors or varistors. The filter significantly improves the dielectric conditions of the transformer winding insulation.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 41--44
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ przemienników częstotliwości na pracę silników indukcyjnych w podziemiach kopalń
Influence of frequency innverters on operation of induction motors in mine environment
Autorzy:
Marek, A.
Powiązania:
https://bibliotekanauki.pl/articles/113133.pdf
Data publikacji:
2017
Wydawca:
STE GROUP
Tematy:
pośredni przemiennik częstotliwości
falownik
MSI
silnik indukcyjny
przepięcie
prąd doziemny
intermediate frequency inverter
inverter
PWM
induction motor
overvoltage
earth leakage current
Opis:
W referacie przedstawiono analizę współpracy pośrednich przemienników częstotliwości z zasilanymi przez nie silnikami indukcyjnymi. Na warunki pracy silników zasilanych z pośrednich przemienników częstotliwości mają w warunkach kopalnianych wpływ parametry elementów pasożytniczych użytych przewodów oponowych lub/i kabli górniczych, parametry elementów wchodzących w skład filtrów oraz sposób sterowania pracą zaworów falownika. Istotną właściwością omawianego przekształtnika jest to, że nie jest on źródłem napięcia sinusoidalnie zmiennego. Odkształcenie napięcia wyjściowego przemiennika jest efektem wielokrotnej komutacji zaworów falownika pracującego przy sterowaniu z modulacją szerokości impulsów (MSI). Z komutacją zaworów falownika związane są duże stromości narastania napięcia wyjściowego przemiennika. Stromości te osiągają wartości dochodzące do kilkunastu kV na s. Tak duże stromości narastania napięcia wyjściowego przemiennika powodują w stanie przejściowym przepływ dużych prądów pojemnościowych. W pracy omówiono wpływ poszczególnych parametrów kabli i przewodów oponowych na wartości przepięć i prądów doziemnych. Omówiono również sposoby ograniczenia tych niekorzystnych zjawisk (przepięć, prądów doziemnych).
The paper contains analysis of cooperation between induction motors with the intermediate frequency inverters that supply them. In the mine environment, parasitic elements of the cables, parameters of the filters’ elements, and a method of control over inverter transistors have an impact on the regime of motors fed by the intermediate frequency inverters. An important feature of such a converter is that it is not a source of sinusoidal voltage. Deformation of voltage output is a result of inverter transistors being switched up multiple times with pulse – width modulation (PWM) control. Large steepness of the converter output rising voltage is related to switching of the transistors. The steepness reaches values of up to a dozen or so kV on s. Such a large steepness of output rising voltage can cause passage of large capacitive currents. The paper discusses also the influence of the parameters of individual cables on values of the overvoltages and earth leakage currents. Various ways to limit this negative phenomena (overvoltage, the earth leakage current) are also discusses in the paper.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2017, 6, 2; 188-196
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Falownik napięciowy oparty na potrójnym mostku H do zasilania silnika trójfazowego z przerwaną fazą
Three phase motor with open phase supplied from voltage inverter based on triple h bridge
Autorzy:
Radecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1369107.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
falownik napięcia
silnik trójfazowy
three-phase motor
voltage inverter
Opis:
In this paper, a voltage inverter based on three independent H-bridges to supply health and faulty motor was presented. Operating conditions of this type of inverter were presented for each open phase. For proposed control scheme that refers to independent control of each phase current, a robust properties of control system was shown. Based on computer simulations and laboratory tests, the effectiveness of squirrel cage induction motor control, supplied from three independent H-bridges was shown in case of dynamic phase opening.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 1, 94; 115-120
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and simulation of novel stepped DC coupled quasi Z-Multilevel Inverter for single phase systems
Autorzy:
Meenakshi, T.
Suthanthira Vanitha, N.
Powiązania:
https://bibliotekanauki.pl/articles/140968.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multilevel inverter
shoot through
quasi Z-Source
modulation index
Opis:
This paper presents the modeling and simulation of a novel topology of quasi Z-Multilevel Inverter with stepped DC input. The proposed inverter incorporates a simple switching technique with reduced component count and is aimed at producing boosted multilevel output AC voltage. The inverter consists of two stages and the buck /boost operation is obtained by varying the shoot through period of the pulses obtained by maximum constant boost control with third harmonic injection. With all the advantages of the quasi Z-network, the proposed inverter eliminates the fly back diodes and capacitors present in a conventional Z-Multilevel Inverter. Further the stress on the devices is less which leads to reduction in component value and hence the cost. The novel stepped DC coupled Single Phase quasi Z-Multilevel Inverter is modeled and simulated in the MATLAB – SIMULINK environment and its performance is analyzed for varying input and switching conditions. The voltage and current waveforms across each stage of the inverter is analyzed and the results are presented for different levels of input.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 437-448
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of space vector modulation strategy on hybrid (Si-SiC) inverter losses
Autorzy:
Bonisławski, M.
Hołub, M.
Powiązania:
https://bibliotekanauki.pl/articles/140592.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik hybrydowy
elektronika energetyczna
urządzenie z szeroką przerwą energetyczną
SVPWM
DPWM
power electronic inverter
SiC diodes
hybrid inverter
wide band gap devices
Opis:
This work summarizes efficiency measurement results of a full bridge, 3 phase inverter composed of state-of-the-art Si IGBT transistors and Si or SiC diodes. Different (symmetrical and discontinuous) space vector modulation strategies were chosen in order to examine their influence (together with modulation frequency) on inverter losses. Induction machine was used as load, different load points were examined. Results clearly show, that proper modulation strategy, minimizing the switching losses of semiconductor switches, can increase the overall output efficiency at about 1% in case of both silicon and hybrid constructions. The drawback of DPWM approach is connected with the decreased quality of inverter output current. Hybrid technology can also improve the output efficiency at about 1% when compared to traditional constructions, but only in case of elevated switching frequencies. At low frequencies (below 10 kHz) modern semiconductor offer comparable results at much lower device costs.
Źródło:
Archives of Electrical Engineering; 2012, 61, 1; 69-75
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A closed-loop power controller model of series-resonant-inverter-fitted induction heating system
Autorzy:
Pal, P.
Roy, D.
Datta, A.
Sadhu, P. K.
Banerjee, A.
Powiązania:
https://bibliotekanauki.pl/articles/141721.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction heating
power controller
PID
series resonant inverter
MATLAB
Opis:
This paper presents a mathematical model of a power controller for a high-frequency induction heating system based on a modified half-bridge series resonant inverter. The output real power is precise over the heating coil, and this real power is processed as a feedback signal that contends a closed-loop topology with a proportional-integral-derivative controller. This technique enables both control of the closed-loop power and determination of the stability of the high-frequency inverter. Unlike the topologies of existing power controllers, the proposed topology enables direct control of the real power of the high-frequency inverter.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 827-841
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model trakcyjnego falownika napięciowego
The model of the voltage traction inverter
Autorzy:
Dominikowski, B.
Pacholski, K.
Woźniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/312485.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
falownik napięciowy
SVPWM
sieć trakcyjna
voltage inverter
traction line
Opis:
W artykule przedstawiono model falownika napięciowego typu DC/AC wykorzystywany w zmodernizowanych elektrycznych zespołach trakcyjnych (EZT). W przekształtniku tym wykorzystano metodę sterowania typu SVPWM (ang. Space Vector Pulse Width Modulation), która pozwala w sposób dokładny odwzorować na jego zaciskach wyjściowych przebiegi napięcia sinusoidalnie zmiennego. Obwód tego typu pracujący w sieci trakcyjnej generuje tętnienia wartości wejściowego prądu o częstotliwości sześciokrotnie wyższej niż częstotliwość jego napięcia wyjściowego. Na wejściu DC obwodu pośredniczącego falownika w elektrycznej trakcji szynowej monitoruje się wartość prądu obciążenia sieci jezdnej m.in. do wyznaczenia pobieranej energii elektrycznej pobranej przez zespół trakcyjny.
In the paper presented the model of the voltage inverter type DC/AC used in modernized electrical traction. In this inverter, the SVPWM (Space Vector Pulse Width Modulation) control method was used which allow to the accurately imitate the voltage sinusoidal variable waveforms on its output connectors. The circuit of this type working in overhead contact line generates pulsations of input-current at a frequency six times higher than the frequency of its output voltage. At the DC input of the inverter circuit in the electric traction rail, the load current of the mains network is monitored. to determine the electricity consumed by the traction unit.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 815-818, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ elementów obwodu elektrycznego na sprawność urządzenia spawalniczego
The influence of electrical circuit elements on the efficiency of welding machine
Autorzy:
Stopczyk, W.
Nawrocki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1368009.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
sprawność energetyczna
spawarka inwertorowa
IGBT
energy efficiency
inverter welder
Opis:
Rising energy costs and problems associated with load capacity of energy sources and environmental protection are the reasons for which it becomes expedient to search for new solutions of circuits welding equipment. Due to the relatively high power ratings of welding equipment, even a small increase in the efficiency of these devices can bring significant benefits. One way to increase the efficiency of welding machines are resonant power conversion techniques. The advantage of these circuits is elimination of switching losses and higher operating frequency compared to conventional circuits. In order to adequately take advantage of the resonance techniques to maximize efficiency of welding equipment, items to build a circuit welder should be selected. The article presents the results of research and discusses the influence of switching elements to improve the efficiency of welding equipment.
Rosnące koszty energii oraz problemy związane z obciążalnością źródeł energii i ochroną środowiska są powodami, dla których staje się celowe poszukiwanie nowych rozwiązań układowych urządzeń spawalniczych. Ze względu na stosunkowo duże moce znamionowe urządzeń spawalniczych, nawet niewielkie zwiększenie sprawności tych urządzeń może przynieść znaczące korzyści. Jednym ze sposobów pozwalających zwiększyć sprawność urządzeń spawalniczych są techniki rezonansowe konwersji energii. Zaletą tych układów jest eliminacja strat przełączania i wyższa częstotliwość pracy w porównaniu z układami klasycznymi. Aby dostatecznie wykorzystać zalety techniki rezonansowej i zmaksymalizować sprawność urządzenia spawalniczego należy właściwie dobrać elementy do budowy obwodu elektrycznego spawarki. W artykule zostały przedstawione wyniki badań oraz omówiony został wpływ elementów przełączających na poprawę sprawności urządzeń spawalniczych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2015, 2, 106; 21-27
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the accuracy of inverter sync angle during the grids disturbances
Autorzy:
Jarzyna, Wojciech
Zieliński, Dariusz
Gopakumar, K.
Powiązania:
https://bibliotekanauki.pl/articles/221529.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inverter synchronization
synchronization angle
PLL
sync error
distributed grid
Opis:
The grid-tied inverter synchronizes with the network on the basis of the instantaneous voltage phase angle. This angle is computed by the so-called synchronization algorithms. During grid disturbances, it is estimated with a certain accuracy, which varies for different disturbances and depends on the choice of algorithm. The tests presented here determine how to make an optimal selection of the synchronization algorithm. The research methods used are modeling, simulation and analysis of the results obtained. One of the most important outcomes is the determination of the root-mean-square sync error and its dynamics denotation. The research conclusions should be of particular interest to designers of distributed energy systems with a large number of inverter energy sources.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 355-371
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiększenie częstotliwości łączeń w falownikach dzięki nowym elementom półprzewodnikowym z węglika krzemu (SiC)
Autorzy:
Zdanowski, M.
Sobieski, R.
Powiązania:
https://bibliotekanauki.pl/articles/302847.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
falownik
element półprzewodnikowy
węglik krzemu
inverter
semiconductor element
silicon carbide
Opis:
Doskonałe właściwości statyczne i dynamiczne tranzystorów SiC MOSFET mogą być wykorzystane do przesunięcia obecnej bariery częstotliwości łączeń, występującej w dotychczas stosowanych krzemowych (Si) elementach półprzewodnikowych falowników napięcia w zakres nawet powyżej 100 kHz.
Źródło:
Napędy i Sterowanie; 2017, 19, 3; 22-24
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decomposition of EMI Noise into Common and Differential Modes in PWM Inverter Drive System
Autorzy:
Kempski, A.
Smoleński, R.
Powiązania:
https://bibliotekanauki.pl/articles/262576.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
electromagnetic compatibility
common mode
differential mode
PWM inverter drive system
Opis:
In this paper [20] an analytical approach to decomposition of total phase EMI noises through algebraic calculations and the Fourier transform has been presented. Separating conducted EMI noise into different, common and differential mode (CM and DM) HF current components is important for a proper spectral analysis and application of EMI mitigation techniques. The results of calculations have been compared to EMI currents measured on the motor side of the PWM drive system. The proposed approach can be useful in comparative analysis of the influence of inverter control algorithms on spectra of CM currents in a given drive system.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 53-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System automatycznego sterowania w pomiarach przepływem wody
The automatic control system in flow measurement
Autorzy:
Szlachta, A.
Odon, A.
Powiązania:
https://bibliotekanauki.pl/articles/268597.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
falownik
przepływomierz
regulator PID
LabVIEW
inverter
flow meter
PID controller
Opis:
Artykuł prezentuje system automatycznego sterowania przepływem wody w obiegu zamkniętym. Omówiono aplikację sterującą przepływem wody na stanowisku. Zaprezentowano wieloczujnikowy system pomiarów. Na omawianym stanowisku przeprowadzane są badania metod statystycznych w pomiarach dwufazowych.
The system of automatic control of the water flow in a closed circuit has been presented in this paper. The laboratory stand allows to control the inverter on the position of research flows. Measurements were concerned a liquid in two-phase (water and air). The application to control the water flow was also discussed. The multi-sensors measurement system was presented. The laboratory stands have been realized for the results verification made obtained from mathematical models, computer simulations and signals acquisition using the stochastic methods. The statistical methods in the measurement of two-phase of statistical methods used in time delay estimation: direct cross-correlation and the function of conditional average value of delayed signal were carried out in the study for this stand.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 137-140
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Initial Excitation Issues of Synchronous Generator with VSI Inverter in Varying Rotational Speed Operation
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/2064987.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
synchronous generator
initial excitation
FOC control
voltage source inverter
synchronization
Opis:
Synchronous self-excited generators still are and probably will be the most popular 3-phase alternators installed in inland power stations so onboard of seagoing ships. Because of fuel savings and environmental restrictions Diesel, dual-fuel and gas propulsion engines for alternators of wide-range varying revolutions drives are increasingly used. There must be efficient way of creating 3-phase voltages of desired constant parameters ensured when generator produces variable amplitudes and frequencies of voltages because of changing rotational speed. As the control method modified field oriented control widely used with squirrel cage induction machines was chosen. This control method involves decoupling of currents and control voltages to flux and torque components and keeping them in optimal (orthogonal) condition. In order to obtain proper excitation and operation of such generator several factors have to be taken into account. Nonlinear dependence of voltage generated from rotational speed of self-excited synchronous generator is one of the factors that affects initial excitation process thus specific control method while generator startup. Theoretical background of synchronous generator excitation and voltage source inverter adopted FOC control method along with experimental results obtained in laboratory test bench of 5,5 kW generator and conclusions were presented.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 377--383
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca układu napędowego drzwi kabinowych z silnikiem synchronicznym przy zasilaniu awaryjnym
Cabin Door Drive System with Synchronous Motor Powered by Emergency Battery
Autorzy:
Kolano, K.
Powiązania:
https://bibliotekanauki.pl/articles/1368558.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
zasilanie awaryjne
przekształtnik
synchronous motor
emergency power
inverter
Opis:
The article presents the basic assumptions of technical operation of the propulsion system of a passenger elevator cabin door powered by emergency battery. It is highly reccomended for electric driver system of the lift doors, to open and close several times when supplying by the emergency battery. It is necessary to develop a control algorithm of synchronous motor operation to provide proper operation of the system performance at lower power. The developed procedure has been tested in the laboratory of the Department of Electrical Machines and Drives, and will be implemented into industrial practice in the New cabin door drive system.
W artykule przedstawione zostały podstawowe założenia techniczne pracy układu napędowego drzwi kabinowych dźwigu osobowego przy zasilaniu ze źródła rezerwowego. Podstawowym wymogiem jest umożliwienie otwarcia drzwi dźwigu po wykonaniu zjazdu awaryjnego z możliwie jak najmniejszą mocą przy wykorzystaniu tylko jednego akumulatora rezerwowego. Aby umożliwić poprawną pracę układu przy obniżonych parametrach zasilania konieczne jest opracowanie specjalnego algorytmu sterowania uwzględniającego charakterystykę pracy silnika synchronicznego. Opracowana procedura została przetestowana w laboratorium Katedry Napędów i Maszyn Elektrycznych i zostanie wdrożona do praktyki przemysłowej w nowym układzie napędowym drzwi kabinowych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 251-254
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania falownikowego napędu pompy wodnej z silnikiem indukcyjnym
The Test Inverter Drive the Water Pump with an Induction Motor
Autorzy:
Drabek, T.
Rusek, J.
Powiązania:
https://bibliotekanauki.pl/articles/1368614.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
diagnostyka
napęd falownikowy
induction motor
diagnostics
inverter driver
Opis:
This paper presents the results of tests of induction water pump drive with an inverter, installed In water supply station. The drive consists of induction motor with a power rating of 132kW, supplyed from voltage inverter with a power rating of 160kW, scalar controlled. The aim of the study was to determine the causes of repeated failures of the inverter. Subject of tests and diagnostic measurements was both, the inwerter and motor. Tests have shown the absence of any abnormalities in the operation of motor, including the lack of damage to the stator and rotor. Over the long-term measurements, there was no overvoltage in the feed of the inverter and the other sections of the drive circuit, that could cause damage of the drive. The conclusion of the tests is to identify the noise in control of the drive as the alleged source of the damage in its power module.
W artykule przedstawiono wyniki badań falownikowego napędu indukcyjnego pompy wodnej, zainstalowanego w wodociągach miejskich. Badany napęd składa się z głębinowego silnika indukcyjnego o mocy znamionowej 132kW, zasilonego z przemiennika częstotliwości o mocy znamionowej 160kW, sterowanego skalarnie. Celem badań było ustalenie przyczyn powtarzających się uszkodzeń części mocy przemiennika. Przedmiotem pomiarów kontrolnych i diagnostycznych był zarówno przemiennik jak i silnik. Badania wykazały brak jakichkolwiek nieprawidłowości w pracy silnika, w tym brak uszkodzeń stojana i wirnika. W ciągu pomiarów długookresowych stwierdzono również brak ew. przepięć na zasilaniu przemiennika i w innych punktach obwodu zasilania napędu, które mogłyby powodować uszkodzenia przemiennika. Konkluzją badań jest wskazanie zakłóceń sterowania samego przemiennika jak domniemanego źródła uszkodzeń jego części mocy.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 13-18
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A wide-band power electronics current source in reference current generator
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/97463.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
control algorithm
DSP
inverter
PWM
stability of an electrical system
Opis:
The paper considers wide-band voltage controlled power electronics current source. The current source has been designed as a part of 1-channel reference current generator designed for current meters testing. The control module of the generator utilizes a specialized Analog Devices Inc. DSPs based microcomputer module for power electronics applications. Used solutions have allowed obtain high quality referencing of the output current within reference signal. The paper presents the structure and selected aspects of the control algorithm of the current source. Also selected investigations results of the laboratory prototype of generator are presented.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 252-257
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on topology of a novel three-phase four-leg fault-tolerant NPC inverter
Autorzy:
Zhang, Baoge
Ping, Shanyan
Long, Yyi
Jiao, Yyuemin
Wu, Bboxiang
Powiązania:
https://bibliotekanauki.pl/articles/2086722.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault tolerant operation
midpoint potential equilibrium
NPC inverter
topology reconstruction
Opis:
Diode neutral point clamped (NPC) three-level converters have been widely used in recent years. Aiming at the problems of the high device failure rate and unstable neutral point potential of NPC three-level converters, an NPC three-level circuit with fourth bridge arm redundancy is proposed based on the traditional NPC three-level converter. The redundant fourth bridge arm is used to realize the function of stabilizing voltage when there is no fault and replacing the fault half-bridge arm to maintain the continuous operation of the converter when there is a fault. By analyzing the working principle of space vector pulse width modulation (SVPWM) and the power loss of the switch, it is of particular significance to the design and control of NPC three-level converters in the future. Matlab/Simulink verifies the feasibility of the fault-tolerant circuit structure.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 489--506
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steady-state time-periodic finite element analysis of a brushless DC motor drive considering motion
Autorzy:
Jagieła, M.
Gwóźdź, J.
Powiązania:
https://bibliotekanauki.pl/articles/141576.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
finite elements
brushless machines
inverter drives
steady-state
mathematical modeling
Opis:
This paper aims at providing a framework for comprehensive steady-state time-domain analysis of rotating machines considering motion. The steady-state waveforms of electromagnetic and circuit quantities are computed via iterative solution of the nonlinear field-circuit-and-motion problem with constraints of time periodicity. The cases with forced speed and forced load torque are considered. A comparison of execution times with a conventional time-stepping transient model is carried out for two different machines. The numerical stability of a time-periodic model with forced speed is shown to be worse than that of traditional transient time-stepping one, although the model converges within a reasonable number of iterations. This is not the case if forced load via equation of mechanical balance is accounted for. To ensure convergence of the iterative process the physical equation of motion is replaced by the fixed-point equation. In this way the model delivers time-periodic solutions regarding not only the electromagnetic quantities but also the rotational speed.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 471-486
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of maximum power point tracking in photovoltaic system under variable solar irradiance
Autorzy:
Marańda, W.
Piotrowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/200627.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
photovoltaics
MPP-tracking
inverter efficiency
fotowoltaika
śledzenie
MPP
sprawność falownika
Opis:
Field conditions decrease the energy output of photovoltaic (PV) systems, mainly due to excessive temperatures. However, in regions with moderate ambient temperatures, as in Poland, solar energy is commonly delivered with highly fluctuating irradiance. This introduces yet another source of energy losses due to the non-ideal tracking of actual position of Maximum Power Point (MPP). Majority of PV-systems are equipped with DC/AC and grid-connected inverter. Since the solar energy flux is variable, an adequate MPP-tracking algorithm is required to handle a wide range of load levels and face rapid changes of input power. Along with the essential DC/AC conversion, the quality of MPP-tracking must also be taken into account in evaluation of inverter efficiency. The tracking in dynamic conditions has been addressed only recently. Several algorithms has been studied theoretically, experimentally or in laboratory conditions by applying artificial input test-patterns. This work takes the opposite approach by applying the recorded real-life solar irradiance and simulating the tracking behavior to study the problem for true field conditions in Poland. The simulation uses the unique high-quality irradiance data collected with 200 ms time resolution. The calculation of both static and dynamic MPP-tracking efficiency has been performed for representative variable-cloudy day, applying commonly used Perturb&Observe tracking algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 4; 713-721
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sub-phase power electronics inverters
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/97361.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inverter
Generalized Sampling Expansion
Whittaker-Kotelnikov-Shannon sampling theorem
WKS
Opis:
Dynamic changes of parameters of energy sources and receivers are reasons that decrease exactitude of output signals towards reference signals. To improve these parameters more advanced solutions of power electronics systems are necessary. Ones of possible solutions are a sub-phase inverters. The output quantity regulator there is based on Generalized Sampling Expansion, being crucial extension of Whittaker-Kotelnikov-Shannon sampling theorem. Wide-band power electronics current source with regulator based on that extension is analyzed further.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 190-199
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of numerically determined noise of a 290 kW induction motor using FEM and measured acoustic radiation
Autorzy:
Nahlaoui, M. Al
Steins, H.
Kulig, S.
Exnowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/140646.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inverter-fed
induction motor
asynchronous machine
acoustic radiation
modal analysis
Opis:
In this paper a comparison of numerically determined and measured electromagnetically exited noise of an induction motor is presented. The calculations are accomplished using FEM for an example motor, which is a 290 kW inverter-fed asynchronous machine. The approach starts with the electromagnetic and mechanical consideration. The focus is set on acoustic considerations, which contain the 3D-FE-model and measurement setup in the sound chamber.
Źródło:
Archives of Electrical Engineering; 2013, 62, 2; 195-207
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multilevel inverter with optimal THD through the firefly algorithm
Autorzy:
El Mehdi Belkacem, R.
Benzid, R.
Bouguechal, N.
Powiązania:
https://bibliotekanauki.pl/articles/141495.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
firefly algorithm (FFA)
genetic algorithm (GA)
inverter
multilevel
optimized THD
Opis:
Reduction of the Total Harmonic Distortion (THD) in multilevel inverters requires resolution of complex nonlinear transcendental equations; in this paper we propose a combination of one of the best existing optimized hardware structures with the recent firefly algorithm, which was used to optimize the THD, through finding the best switching angles and guaranteeing the minimization of harmonics within a user defined bandwidth. The obtained THD through the simulation of the thirteen-level symmetric inverter has been reduced down to 5% (FFT of 60 harmonics). In order to validate the simulation results, a thirteen-level symmetric inverter prototype has been made, and practically experimented and tested with different loads. Consequently, the measured THD with resistive load was 4.7% on a bandwidth of 3 kHz. The main advantage of the achieved work is the reduction of the THD.
Źródło:
Archives of Electrical Engineering; 2017, 66, 1; 141-154
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies