Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Cooling water" wg kryterium: Temat


Wyświetlanie 1-49 z 49
Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical Problems and Ecological Risks in Connection with Operation of Cooling Water Systems
Techniczne problem I zagrożenia ekologiczne związane z eksploatacją systemów wody chłodzącej
Autorzy:
Skoczylas, A.
Falewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/389734.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
układy wody chłodzącej
korozja
związki fosfonowe
cooling water systems
corrosion
phosphonic compounds
Opis:
Industrial water consumption in Poland is very high and reach over 10 billion m3/year, which forces the implementation of appropriate programs and technological solutions to reduce water consumption in industrial activity. Depending on the design system, operating conditions of water-powered cooling systems, they are exposed to varying degrees of corrosion, precipitation and deposition of sediments and the growth of microorganisms in water circulating. So important are measures aimed at raising the technical level of operation of industrial water systems. One of the most promising ways to prevent negative phenomena in the operation of cooling water systems is the use of organic inhibitors of complex multi-functional system to protect against corrosion, deposition of sediments and the development of microorganisms in the water circulation.
Zużycie wody przemysłowej w Polsce jest bardzo duże i wynosi ponad 10 mld m3/rok, co zmusza do wdrażania odpowiednich programów i rozwiązań technologicznych w celu zmniejszenia zapotrzebowania na wodę. W zależności od rozwiązań konstrukcyjnych, warunków eksploatacji układów chłodzących zasilanych wodą, narażone są one w różnym stopniu na korozję, wytrącanie i odkładanie się osadów oraz rozwój mikroorganizmów w wodzie obiegowej. Dlatego ważne są działania mające na celu podnoszenie poziomu technicznego eksploatacji przemysłowych układów wodnych. Jednym z najbardziej perspektywicznym sposobem zapobiegania negatywnych zjawisk występujących przy eksploatacji układów wody chłodzącej jest stosowanie ekologicznych wielofunkcyjnych inhibitorów kompleksowo chroniących układ przed korozją, odkładaniu się osadów i rozwojem mikroorganizmów w wodzie cyrkulacyjnej.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 9; 1115-1122
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of cooling water temperature on the performance of a BWR nuclear power plant
Autorzy:
Laskowski, Rafał
Theimech, Mohamad
Uzunow, Nikołaj
Powiązania:
https://bibliotekanauki.pl/articles/2195750.pdf
Data publikacji:
2021
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
nuclear power plant
cooling system
cooling water temperature
boiling water reactor
BWR
elektrownia jądrowa
układ chłodzenia
temperatura wody chłodzącej
reaktor wrzący
Opis:
Although PWR reactors make up the large majority of the world's nuclear power plants, BWR reactors also have a share in this industry. It is difficult to find data on the performance of a BWR power plant in off-design and variable load conditions in the literature. Therefore, the paper presents how cooling water temperature affects the efficiency and power output of a BWR unit. The qualitative effect of changes and the trend related to the effect of cooling water temperature on the performance of the power plant are known, but the quantitative effect has to be determined for specific power units. Depending on the location of the nuclear power plant, various temperatures of cooling water for use in condensers and thus various operating conditions of the cooling system can be achieved. To analyze how cooling water temperature affects the performance of the power unit, a model of a BWR power plant was developed using the Ebsilon software. The model was based on data provided in [1] concerning LaSalle County Nuclear Generating Station. Calculations showed that within the examined range of cooling water temperatures at the condenser inlet between 10 and 28oC the gross power output of the unit decreases by 91.405 MW and the gross efficiency drops by 2.773 percentage points.
Źródło:
Modern Engineering; 2021, 3; 5--13
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of wastewater to meet the requirements for cooling water systems in jordan’s nuclear plants
Autorzy:
Al-Rawajfeh, A.E.
Araj, K.
Powiązania:
https://bibliotekanauki.pl/articles/184961.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
nuclear plants
wastewater treatment
scale deposition
schładzanie wody
elektrownia jądrowa
oczyszczanie ścieków
Opis:
Scaling and corrosion associated with the use of natural hard water in cooling towers during recirculation pose great problems from both economical and technical points of view, such as decreased system efficiency and increased frequency of chemical cleaning. Treated municipal wastewater (MWW) is a promising alternative to freshwater as power plant cooling system makeup water, especially in arid regions. In this work, hybrid systems of salt precipitation (SP), nanofiltration (NF) and reverse osmosis (RO) were investigated, as potential pretreatment processes for wastewater reuse as cooling water in the planned Jordan nuclear power plants. The As-Samra wastewater was used to calculate the potential of carbonate and sulfate scale formation. The results were compared to scale potentials from Palo Verde wastewater. Four cases were investigated; SP, NF, SP-RO and NF-RO. The SP pretreatment cases showed the highest monovalent to divalent ratio because of a high removal of Ca and Mg and addition of Na from the chemicals of the SP step. The NF pretreatment cases, showed the lowest calcium sulfate scale potential and this potential decreases with the % pretreatment. The scale amount increases very slightly with concentration times when the SP and NF product is desalinated by RO step.
Źródło:
Chemical and Process Engineering; 2013, 34, 2; 253-267
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wystepowanie bakterii z rodzaju [Legionella] w systemach wody chlodniczej
Occurrence of bacteria from the Legionella genus in cooling water systems
Autorzy:
Matuszewska, R
Krogulska, B.
Powiązania:
https://bibliotekanauki.pl/articles/874257.pdf
Data publikacji:
2008
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
woda chlodnicza
klimatyzacja
bakterie
Legionella
wystepowanie
oznaczanie
cooling water
air conditioning
bacteria
occurrence
determination
Opis:
W publikacji przedstawiono wyniki badań próbek wody w kierunku wykrywania bakterii z rodzaju Legionella, z przemysłowych obiegów wody chłodniczej oraz systemów klimatyzacyjnych. Na 518 zbadanych próbek, pobranych w okresie od 1998 do 2006 roku, pałeczki Legionella zostały wykryte w 168 próbkach, co stanowiło 32,4% wszystkich zbadanych próbek. Najbardziej niebezpieczna Legionella pneumophila sg 1 była wykrywana w 11,3 % próbek pozytywnych. Niepokój budzi również wysoka liczba wyizolowanych bakterii z rodzaju Legionella (powyżej 103jtk/100ml), którą stwierdzono aż w 60% próbek wody pobranych z systemów wody chłodniczej i w 33% próbek wody związanych z klimatyzacją. Tak wysoki poziom zanieczyszczenia wymaga natychmiastowej interwencji (czyszczenie i dezynfekcja urządzeń). Uzyskane wyniki wskazują na realne zagrożenie zdrowotne jakie związane jest ze skażeniem wód chłodniczych pałeczkami Legionella. Należy zatem dążyć do powstania uregulowań prawnych, które nakładałyby obowiązek monitorowania wód chłodniczych w kierunku bakterii z rodzaju Legionella i prowadzenia odpowiednich działań naprawczych.
Results of Legionella bacteria study in water samples from industrial cooling water systems and airconditioner systems were presented. Legionella pneumophila was detected in 32,4%. of 518 examined water samples collected from 1998 to 2006. The most dangerous Legionella pneumophila sg 1 was detected in 11,3% of all positive samples. The high number (more than 104jtk/l) of isolated Legionella bacteria was determinated in 60% of water samples taken from cooling waters systems and 33% of samples of waters related with air-conditioning that is alarming. High pollution requires immediate intervention (installations cleaning and disinfection). Data indicated real health risk connected with Legionella pollution of cooling water. Creation of low regulations which will put the obligation of cooling water systems monitoring of Legionella bacteria occurrence and taking preventive measures is necessary.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2008, 59, 4; 445-454
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Razrabotka i issledovanie prisadki novogo tipa
Development and Testing of a New Kind of Additive
Autorzy:
Valisin, A.
Pimosenko, A.
Powiązania:
https://bibliotekanauki.pl/articles/359373.pdf
Data publikacji:
2006
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
concentration
corrosion-erosion destruction
cooling water additive
chemical nickeling
cylinder liner
EXPLO-SHIP 2006
Opis:
The article considers the question of obtaining a new additive on the base of nickel salts for ship's diesel engine cooling water. The protective property of this additive results from chemical nickeling of surfaces to be cooled without using any power source. The article describes the results of testing the additive on a test rig equipped with a magnetostriction vibrator.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2006, 10 (82); 399-406
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniczne i ekologiczne problemy przy eksploatacji przemysłowych układów wody chłodzącej
Technical and environmental problems in the operation of industrial systems cooling water
Autorzy:
Skoczylas, A.
Falewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/126042.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
układy wody chłodzącej
korozja
ekologiczne inhibitory korozji
cooling water system
corrosion
ecological corrosion inhibitors
Opis:
Zużycie wody przemysłowej w Polsce jest bardzo duże i wynosi ponad 10 mld m3/rok, co zmusza do wdrażania odpowiednich programów i rozwiązań technologicznych w celu zmniejszenia zapotrzebowania na nią. W zależności od rozwiązań konstrukcyjnych, warunków eksploatacji układów chłodzących zasilanych wodą narażone są one w różnym stopniu na korozję, wytrącanie i odkładanie się osadów oraz rozwój mikroorganizmów w wodzie obiegowej. Dlatego istotne są działania mające na celu podnoszenie poziomu technicznego eksploatacji przemysłowych układów wodnych. Stosowanie ekologicznych wielofunkcyjnych inhibitorów wydaje się być jednym z najbardziej perspektywicznych sposobów chroniących układ przed korozją, odkładaniem się osadów i rozwojem mikroorganizmów w wodzie cyrkulacyjnej, występujących przy eksploatacji układów wody chłodzącej.
Industrial water consumption in Poland is very high and amounts to over 10 billion m3, which meansthal the implementation of relevant programs and technological solutions to reduce demand for water is needed. Depending on the design system, operating conditions of refrigeration systems powered by water, they are exposed to varying degrees of corrosion, precipitation and deposition of sediments and the development of microorganisms in the water circulation. So important are measures aimed at improving the technical operation of industrial water systems. One of the most promising way to prevent negative phenomena in the operation of the cooling water systems is the use of organic inhibitors of complex multi-functional system to protect against corrosion, deposition of sediments and the development of microorganisms in the water circulation.
Źródło:
Proceedings of ECOpole; 2011, 5, 2; 595-599
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Procesy korozyjne w wieżach chłodniczych – badania stali zbrojeniowych w środowisku wody chłodniczej, uzdatnionej solami amonowymi
Corrosion processes in cooling towers
Autorzy:
Szymura, T.
Adamczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/391195.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
układy chłodnicze
woda chłodnicza
korozja metali
korozja żelbetu
inhibitory korozji
Cooling water
corrosion metals
corrosion concrete construction
cooling system
inhibitors
Opis:
Przeprowadzono badania korozji stali zbrojeniowych w uszkodzonych płaszczach chłodni kominowej w środowisku wody chłodniczej, uzdatnianej związkami siarczanu i chlorku amonu. Badania prowadzono normową metodą grawimetryczną i elektrochemiczną z wykorzystaniem potencjostatu. Badania wykazały, że odporność korozyjna w roztworach zawierających sole amonu o stężeniu 0,15 mola/dm3, obliczona na podstawie szybkości korozji, była podobna i wyniosła 6 (w skali od 1 do 10). Stal S235JRG2 wykazała nieco wyższą odporność w tych środowiskach.
Corrosion testing was performed on structural steel of a cooling tower in the environment of cooling water containing ammonium sulfates and ammonium chloride. The test were performed using gravimetric and electrochemical methods with the application of a potentiostat. The analyses clearly showed that the corrosion rate is higher in solutions that contain ammonium sulfate and that the S235JRG2 steel exhibits higher corrosion resistance in this environment.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 231-238
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study of Temperature Influence on the Performance of PV/T Cell under Jordan Climate Conditions
Autorzy:
Al-Odat, Mohammed Qassim
Powiązania:
https://bibliotekanauki.pl/articles/2202185.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PV module
electrical conversion
electrical efficiency
water cooling
cooling
cell temperature
Opis:
The electrical performance and the productivity of PV module depend on two main parameters, i.e. the radiation intensity and the cell operating temperature. The module electrical efficiency and productivity are significantly reduced as its temperature increases. Accordingly, cooling of PV modules is one of the most effective techniques to obtain higher efficiency and productivity as well as to reduce the degradation modes of PV modules due to high temperatures. This research work presents an experimental study carried out to investigate the effect of PV module cooling on the performance of PV module under Irbid city (Jordan) climate conditions. It was found that the electrical efficiency and the productivity of the PV modules were approximately enhanced by 14%. Therefore, water cooling of the PV modules is essential to enhance their performance.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 80--88
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increasing photovoltaic panel power through water cooling technique
Autorzy:
Matias, C. A.
Santos, L. M.
Alves, A. J.
Calixto, W. P.
Powiązania:
https://bibliotekanauki.pl/articles/136175.pdf
Data publikacji:
2017
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
photovoltaic panel
water cooling
increasing electrical efficiency
efficiency increase
Opis:
This paper presents the development of a cooling apparatus using water in a commercial photovoltaic panel in order to analyze the increased efficiency through decreased operating temperature. The system enables the application of reuse water flow, at ambient temperature, on the front surface of PV panel and is composed of an inclined plane support, a perforated aluminum profile and a water gutter. A luminaire was specially developed to simulate the solar radiation over the module under test in a closed room, free from the influence of external climatic conditions, to carry out the repetition of the experiment in controlled situations. The first case study was published at EEEIC2016 conference where the panel was submitted to different rates of water flow, from 1 L/min to 4 L/min. In the test conditions without cooling apparatus, the panel reached about 70°C and produced approximately 63Wh. With the cooling apparatus with water flow rate of 2 L/min, the module reached about 50°C and produced approximately 77Wh. However, it has been observed that this water flow was overestimated. A second case study was carried out in order to perform the threshold between the flow and the energy produced. The best ratio was flow of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system. The best water flow rate was of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system.
Źródło:
Transactions on Environment and Electrical Engineering; 2017, 2, 1; 60-66
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Renowacja kolektora wody chłodzącej w elektrowni Konin
Renovation of a cooling water collector at Konin power plant
Autorzy:
Abel, T.
Powiązania:
https://bibliotekanauki.pl/articles/163621.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
Elektrownia Konin
kolektor wody chłodzącej
remont
technologia
MAXI-LINING
KANREM
Konin power plant
cooling water collector
renovation
technology
Opis:
W pracy przedstawiono projekt oraz etapy realizacji renowacji rurociągu zlokalizowanego na terenie Elektrowni Konin. W projekcie tym wykorzystano bezwykopowe technologie renowacji rurociągów wielkowymiarowych.
This article describes the design and stages of construction of a pipeline on the site of the Konin power plant. The project involved the use of trenchless technologies for the renovation of large pipelines.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 5, 5; 112-115
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Filtracja magnetyczna wody chłodzącej zapobiegająca tworzeniu się osadów w układach chłodzenia silników spalinowych lokomotyw
Magnetic filtration of cooling water that prevents scale formation in the cooling systems of locomotive diesel engines
Autorzy:
Laptev, Vladimir
Babel, Marek
Powiązania:
https://bibliotekanauki.pl/articles/34572969.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
filtracja magnetyczna
woda chłodząca
osad
układ chłodzenia
lokomotywa
silnik spalinowy
magnetic filtration
cooling water
sediment
locomotive
diesel engines
Opis:
W artykule zaprezentowano metodę filtracji wody w układzie chłodzenia silników lokomotyw spalinowych poprzez zastosowanie aparatu magnetycznego, hydrocyklonu i zaworu regulacyjnego. Zastosowana metoda zapobiega powstawaniu osadów (kamienia kotłowego) i korozji na powierzchniach płaszczy wodnych tulei cylindrowych, przewodów wodnych i sekcji chłodzących. Opisano procesy chemiczne i fizyczne zachodzące w trakcie ciągłej filtracji wody chłodzącej. Zaprezentowano sposoby zabudowy zestawów filtrujących w różnych układach chłodzenia silników lokomotyw spalinowych. Przedstawiono przykłady zabudowanych elementów układu filtracji na lokomotywach spalinowych wraz z wynikami eksploatacyjnymi efektywności filtracji wody chłodzącej.
The article presents a method of water filtration used in the cooling system of the locomotive’s diesel engine which involves the installation of magnetic apparatus, centrifugal filter and a control valve. This method prevents scale and corrosion formation on the surfaces of cylinder cooling jackets, water pipelines and cooling- system sections. There are chemical and physical processes described that occur during continuous filtration of the cooling water. Furthermore the article presents ways in which filtration units are installed in various cooling systems of diesel locomotive engines. The examples of the installed elements of the filtration system in diesel-engine locomotives together with the operational results regarding the effectiveness of cooling water filtration are also presented.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2013, 3; 39-42
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water trophy assessment of the cooling system of the “Dolna Odra” power plant on the basis of algae indicator organisms
Ocena trofii wód układu chłodzącego elektowni „Dolna Odra” na podstawie składu jakościowego organizmów wskaźnikowych glonów
Autorzy:
Kowalski, Wojciech
Komarzewska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2183584.pdf
Data publikacji:
2022-11-14
Wydawca:
Uniwersytet Pedagogiczny im. Komisji Edukacji Narodowej w Krakowie
Tematy:
wody pochłodnicze
gatunki wskaźnikowe
fitoplankton
wskaźnik saprobowy
trofia wodna infrastruktury hydrologicznej elektrowni
after-cooling water
indicator species
phytoplankton
saprobic index
water trophy of the powerplant’s hydrological infrastructure
Opis:
The paper presents the results of water trophy assessment from various stations of the cooling system of the “Dolna Odra” (Poland) power plant. The assessment was made based on the indicator phytoplankton species collected four times at four sites located in different parts of the hydrological system cooling the technical infrastructure of the power plant. The sites were characterised by water with a natural temperature for individual seasons, as well as by thermals changed as a result of the discharge of cooling waters. For each site, the saprobic index was calculated based on indicator species. The analysis showed that the changes in trophic conditions, both in waters with changed thermals and in waters not subject to the influence of after-cool waters, are not subject to significant changes. The waters of all studied sites in the analysed periods of the year should be classified according to Sladeček and Sládečková (1996) to the waters of the β–mesosaprobic zone, with a saprobic index value ranging from 1.51 to 2.50 (average S = 2.0). This zone is characterised by the course of biochemical processes under aerobic conditions, as a result of which complete oxidation of the intermediate products of decomposition of organic compounds takes place.
W pracy przedstawiono wyniki oceny trofii wód z różnych stanowisk układu chłodniczego elektrowni „Dolna Odra” (Polska). Oceny dokonano w oparciu o wskaźnikowe gatunki fitoplanktonu zebranego w czterech terminach roku na czterech stanowiskach, zlokalizowanych w różnych częściach systemu hydrologicznego, schładzającego infrastrukturę techniczną elektrowni. Stanowiska charakteryzowały się wodami o temperaturze naturalnej dla poszczególnych pór roku, jak i zmienną termiką w wyniku zrzutu wód pochłodniczych. Dla każdego stanowiska obliczono indeks saprobowy na podstawie gatunków wskaźnikowych. Analiza wykazała, że zmiany w zakresie trofii, zarówno w wodach o zmienionej termice, jak i wodach nie podlegających oddziaływaniu wód pochodniczych, nie ulegają istotnym zmianom. Wody wszystkich badanych stanowisk w analizowanych okresach roku należy zaklasyfikować wg Sladeček i Sládečková (1996) do wód strefy β–me- zosaprobowej, mających wartość indeksu saprobowości w granicach od 1,51 do 2,50 (średnio S = 2,0). Strefa ta charakteryzuje się przebiegiem procesów biochemicznych w warunkach aerobowych, w wyniku których zachodzi całkowite utlenienie pośrednich produktów rozkładu związków organicznych.
Źródło:
Annales Universitatis Paedagogicae Cracoviensis Studia Naturae; 2022, 7; 145-170
2543-8832
2545-0999
Pojawia się w:
Annales Universitatis Paedagogicae Cracoviensis Studia Naturae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiana temperatury wody chłodzącej skraplacz górniczej chłodziarki powietrza w wentylatorowej chłodnicy wyparnej
Temperature change of condenser cooling water of mine air refrigerator in the ventilating evaporative cooler
Autorzy:
Nowak, B.
Filek, K.
Powiązania:
https://bibliotekanauki.pl/articles/350190.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
klimatyzacja kopalń
chłodzenie wody
chłodnica wyparna
mine air conditioning
water cooling
evaporative cooler
Opis:
Praca traktuje o wentylatorowej wyparnej chłodnicy wody przeznaczonej do schładzania skraplacza sprężarkowej górniczej chłodziarki powietrza. Z bilansów masy i entalpii mediów płynących przez chłodnicę (powietrza, wody chłodzonej i wody zraszającej) wyprowadzone zostały równania stanowiące jej matematyczny model dla stanu ustalonego, przy czym nie uwzględniono tu rozłożonego w przestrzeni charakteru zmian parametrów mediów w chłodnicy, lecz przyjęto jej skupiony charakter i związane z tym skokowe ich zmiany. W pracy przedstawiono też wyniki przykładowych obliczeń wykonanych przy użyciu, utworzonego w oparciu wyprowadzone równania matematycznego opisu chłodnicy, programu komputerowego. Zbadano 27 wariantów, różniących się między sobą wartościami parametrów mediów na wlocie chłodnicy. Wyniki obliczeń zestawiono w tabeli.
The work treats of ventilator evaporative cooler of water, which is intended for cooling of mine compressor air cooler condenser. From mass and enthalpy balances of medium flowing through the cooler (air, cooling water and spraying water) the equations from mathematical model for steady state were introduced; the spread in space character of medium parameter changes in the cooler was not taken into account but its concentrated character and connected with that fact jumping changes were accepted. In the work, the results of example calculations were made by using computer program, which is created on the basis of introduced mathematical equations of cooler description. 27 variants, which are differed from each other in parameter values of medium at the inlet of cooler, were studied. Results of calculations are compiled in a table.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 1; 53-62
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Slab Temperature, Thermal Stresses and Fractures Computed with the Implementation of Local and Average Boundary Conditions in the Secondary Cooling Zones
Autorzy:
Hadała, B.
Malinowski, Z.
Telejko, T.
Powiązania:
https://bibliotekanauki.pl/articles/355729.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
continuous casting of slabs
water spray cooling
local heat transfer coefficient
Opis:
The numerical simulations of the temperature fields have been accomplished for slab casting made of a low carbon steel. The casting process of slab of 1500 mm in width and 225 mm in height has been modeled. Two types of boundary condition models of heat transfer have been employed in numerical simulations. The heat transfer coefficient in the first boundary condition model was calculated from the formula which takes into account the slab surface temperature and water flow rate in each secondary cooling zone. The second boundary condition model defines the heat transfer coefficient around each water spray nozzle. The temperature fields resulting from the average in zones water flow rate and from the nozzles arrangement have been compared. The thermal stresses and deformations resulted from such temperature field have given higher values of fracture criterion at slab corners.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 4; 2027-2036
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wartości współczynników wymiany ciepła i masy w wentylatorowej wyparnej chłodnicy wody
Values of coefficients of heat and mass exchange in evaporated type of water cooler
Autorzy:
Nowak, B.
Filek, K.
Branny, M.
Powiązania:
https://bibliotekanauki.pl/articles/350188.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
klimatyzacja kopalń
chłodzenie wody
chłodnica wyparna
mine air conditioning
water cooling
evaporative cooler
Opis:
W artykule podano wyniki eksperymentalnych badań, w warunkach laboratoryjnych, wentylatorowych wyparnych chłodnic wody, wykorzystywanych w klimatyzacji kopalń podziemnych. Badania te objęły dwa typy chłodnic - RK-450 i CWW-420; mierzono wlotowe i wylotowe parametry wody chłodzonej, wody zraszającej i powietrza. Podano też wyliczone na podstawie pomiarów wartości współczynników wymiany ciepła i masy w takiej chłodnicy: współczynnika przenikania ciepła przez przeponę (k) oraz współczynników wnikania ciepła (a) i masy (b) od wody zraszającej do powietrza. W odniesieniu do współczynników k i a wyznaczono proste regresji i współczynniki korelacji liniowej dla ich zależności od wlotowej temperatury wody chłodzonej. Wyniki pomiarów i obliczeń zestawiono w tabelach i na wykresach.
Results of experimental studies of the performance of fan evaporative type of water coolers are presented in this paper. Tests were conducted with two types of coolers - RK-450 and CWW-420. Parameters of cooled and spray water and of the air were measured. On the base of data collected during laboratory experiments, coefficients of heat and mass exchange were calculated for both tested coolers. Among this coefficient are: overall heat-transfer coefficient through membrane (k), convective heat-transfer coefficient (alpha) and coefficient of mass exchange (P) between spray water and the air. There were determined regression lines and coefficients of linear correlation for k and a in dependence of inlet water temperature. The results of experiments and calculations are presented in the form of plots and tables.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 1; 63-75
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układy poligeneracyjne do skojarzonej produkcji energii elektrycznej, ciepła i chłodu
Polygeneration systems for cogeneration of electricity, heat and cooling
Autorzy:
Nowak, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2069863.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
sorpcja
produkcja chłodu i wody pitnej
poligeneracja
polygeneration
sorption
cooling and drinking water production
Opis:
Najpopularniejszym rozwiązaniem trójgeneracyjnym jest skojarzenie generatora energii elektrycznej, najczęściej silnika gazowego, z węzłem odbioru ciepła oraz z absorpcyjnym agregatem chłodniczym wykorzystującym do produkcji wody lodowej wodę gorącą. Rozwiązania tego typu odznaczają się wysoką efektywnością energetyczną, jak również doskonałą elastycznością pracy, bowiem w okresie letnim nadwyżka produkowanego ciepła wykorzystywana jest przez agregat absorpcyjny do produkcji chłodu, przez co znacznej redukcji ulega zapotrzebowanie na energię elektryczną na cele chłodnicze. W pracy zaprezentowano system do skojarzonej produkcji energii elektrycznej, ciepła i chłodu z dodatkową funkcją odsalania wody oraz oczyszczania ścieków. System pozwala na osiągnięcie bardzo wysokiej efektywności energetycznej dzięki racjonalnemu wykorzystaniu ciepła odpadowego generowanego przez silniki Diesla.
The most popular tri-generation solution is the combination of an electricity generator, most often a gas engine, with a heat collection node and an absorption chiller that uses hot water to produce chilled water. Solutions of this type are characterized by high energy efficiency, as well as excellent flexibility of operation, because during the summer the surplus heat produced is used by the absorption chiller to produce cooling, which significantly reduces the need for electricity for cooling purposes. The paper presents a system for cogeneration of electricity, heat and cooling with an additional function of water desalination and sewage treatment. The system allows to achieve very high energy efficiency through rational use of waste heat generated by diesel engines.
Źródło:
Energetyka Rozproszona; 2021, 4; 63--70
2720-0973
Pojawia się w:
Energetyka Rozproszona
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Study of 2060-T8 Al-Li Alloy Friction Stir Welded Joints Between Natural Cooling and Water Cooling
Autorzy:
Ma, Lin
Niu, Shiyu
Ji, Shude
Gong, Peng
Powiązania:
https://bibliotekanauki.pl/articles/355846.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
2060-T8 Al-Li alloy
friction stir welding
water cooling
microstructure
mechanical properties
Opis:
2060-T8 Al-Li alloy was friction stir butt welded under natural and water cooling conditions. Microstructures and mechanical properties of the welding joints were mainly compared and discussed. By spraying water on the top surface of stir zone, the grain size was reduced, attributing to the improvement of microhardness. The maximum tensile strength under the water cooling reached 461.1 MPa. The joint fractured at the stir zone due to the thickness reduction and the joint softening. The fracture surface consisted of many dimples with various sizes, indicating the typical ductile fracture. The strategy to apply the low heat input at the welding stage and high cooling rate at the cooling stage during FSW is necessary to obtain a high-quality FSW joint.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 1; 305-312
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simplified method of water cooled exhaust system design and performance assessment
Autorzy:
Dymarski, Cz.
Narewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/2073616.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
diesel engine
exhaust gas
water cooling
thermal signature suppression
silnik diesla
silnik wysokoprężny
chłodzenie wodne
Opis:
The water cooled exhaust systems are not often used onboard ships. Prime goal is to lower temperature of exhaust gas from main propulsion and auxiliary engines to the defined limit. The design of such systems require detailed analysis of propulsion system operational parameters to meet designer expectations. The paper outlines the cooled exhaust system design problems in specific application. The simplified method of evaluation of expected cooling water flow requirements has been developed. Based on marine diesel engines test bench data, the results of short analysis of cooling water demand for two different diesel engines are presented. A simplified engineering approach may be useful for assessment of exhaust gas cooling system performance in commercial application like rescue vessels wet exhaust design or exhaust gas cleaning systems.
Źródło:
Journal of Polish CIMEEAC; 2016, 11, 1; 23--29
1231-3998
Pojawia się w:
Journal of Polish CIMEEAC
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the average and local boundary condition of heat transfer during cooling with a water spray under surface boiling
Autorzy:
Jasiewicz, Elżbieta
Hadała, Beata
Malinowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/29520235.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
water spray cooling
heat transfer coefficient
heat flux
inverse problem
heat conduction equation
Opis:
The study determined the local and average heat transfer coefficient and the heat flux on the surface of a cylinder cooled with a water nozzle. The inverse method was used to identify the heat transfer coefficient. An objective function was defined to determine the distance between the measured and calculated temperatures. Two models describing the heat transfer coefficient on the cooled surface were considered. The first model described changes in the heat transfer coefficient as a function of the sample radius and cooling time, and the second one assumed the dependence of the heat transfer coefficient solely on time. Numerical simulations showed significant differences in the determined heat transfer coefficients depending on the adopted model of the boundary condition. The performed tests included experimental temperature measurements at selected points of the sensor, numerical simulations of temperature changes, and the inverse solution.
Źródło:
Computer Methods in Materials Science; 2020, 20, 4; 147-155
2720-4081
2720-3948
Pojawia się w:
Computer Methods in Materials Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operating characteristics of transcritical CO2 heat pump for simultaneous water cooling and heating
Autorzy:
Sarkar, J.
Bhattacharyya, S.
Powiązania:
https://bibliotekanauki.pl/articles/240930.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
charakterystyki pracy
eksperyment
pompa ciepła
symulacja
CO2 heat pump
experiment
performance characteristics
simulation
Water cooling and heating
Opis:
The effects of water-side operating conditions (mass flow rates and inlet temperatures) of both evaporator and gas cooler on the experimental as well as simulated performances (cooling and heating capacities, system coefficient of performance (COP) and water outlet temperatures) of the transcritical CO2 heat pump for simultaneous water cooling and heating the are studied and revised. Study shows that both the water mass flow rate and inlet temperature have significant effect on the system performances. Test results show that the effect of evaporator water mass flow rate on the system performances and water outlet temperatures is more pronounced (COP increases by 0.6 for 1 kg/min) compared to that of gas cooler water mass flow rate (COP increases by 0.4 for 1 kg/min) and the effect of gas cooler water inlet temperature is more significant (COP decreases by 0.48 for given range) compared to that of evaporator water inlet temperature (COP increases by 0.43 for given range). Comparisons of experimental values with simulated results show the maximum deviation of 5% for cooling capacity, 10% for heating capacity and 16% for system COP.
Źródło:
Archives of Thermodynamics; 2012, 33, 4; 23-40
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemiczne aspekty energetyki jądrowej w projekcie Narodowego Centrum Badań i Rozwoju "Technologie wspomagające bezpieczny rozwój energetyki jądrowej"
Chemical aspects of nuclear power in the National Centre of Research and Development project „Technologies supporting the safe development of nuclear power”
Autorzy:
Michalik, J.
Powiązania:
https://bibliotekanauki.pl/articles/214495.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
chemia cyklu paliwowego
chemia wody układu chłodzącego
generacja wodoru
fuel cycle chemistry
chemistry of water cooling system
hydrogen generation
Opis:
Artykuł przedstawia najważniejsze rezultaty prac prowadzonych w ramach trzech zadań projektu strategicznego Narodowego Centrum Badań i Rozwoju „Technologie wspierające rozwój bezpiecznej energetyki jądrowej” dotyczących chemicznych aspektów energetyki jądrowej. W realizacji tych zadań koordynowanych przez Instytut Chemii i Techniki Jądrowej uczestniczyło 14 różnych instytucji.
The article presents the most important results of three research tasks in NCBR (National Centre of Research and Development) strategic project “Technologies supporting the safe development of nuclear power” related to chemical aspects of nuclear energy production. Fourteen institutions coordinated by the Institute of Nuclear Chemistry and Technology had been working on different topic related to those research tasks.
Źródło:
Postępy Techniki Jądrowej; 2015, 2; 14-15
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elementy indukcyjne i transformatory chłodzone wodą
Induction elements and transformers water cooled
Autorzy:
Łukiewski, Mirosław
Łukiewska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/2056417.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
dławik
chłodzenie wodne
panel chłodzący
chłodnica rurowa
rdzenie proszkowe
materiały amorficzne
materiały nanokrystaliczne
transformer
choke
water cooling
cooling panel
tubular cooler
powder cores
amorphous material
nanocrystalline material
Opis:
W artykule omówiono wybrane zagadnienia konstrukcyjne i technologiczne stosowane w produkcji elementów indukcyjnych i transformatorów z chłodzeniem wodnym. Przedstawiono wyniki symulacji wpływu rodzaju materiału magnetycznego rdzenia na wymiary dławika filtru sinusoidalnego typu SinECOTM pracującego przy częstotliwości sieciowej oraz dla transformatora mocy typu 1TTFW pracującego przy częstotliwości 10kHz. Przedstawiono również konstrukcję dławika z odczepami typu 1RTFW przeznaczonego do pracy z częstotliwością 25kHz. Parametry obliczeniowe wyznaczono wykorzystując oprogramowanie projektowe firmy RALE Engineering GmbH.
In this article selected issues related to the construction and technology of the water cooling transformers and induction elements were discussed. The impact of the magnetic core material type on the size of the SinECOTM type choke working with 50Hz frequency and 1TTFW type power transformer working with 10kHz frequency was simulated. Moreover, the construction of the 1RTFW type choke working with 25 kHz frequency was introduced. The parameters were simulated using design software by RALE Engineering GmbH.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2021, 2, 126; 71--76
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of environmental and human impacts of using Strong Alkaline Water for cooling during machining
Autorzy:
Da Silva, P.
Tanabe, I.
Junior, D. C. R.
Takahashi, S.
Powiązania:
https://bibliotekanauki.pl/articles/99481.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
eco-friendly
strong alkaline water
emission
cooling
Opis:
An eco-friendly manufacturing approach is important for the environment. Enhancing machining performances is not only required to improve product’s quality, time saving, and reduces costs; it is also contributed to the environmental protection efforts. Cooling is important aspect for obtaining this purpose. Therefore the benefits of Strong Alkaline Water (SAW) cooling method was assessed and compared with conventional wet cutting method. An experiment was performed at Nagaoka University of Technology machining centre. Three machine tools including a milling machine, a drilling machine and a turning machine were used. The study shows that using SAW for cooling is far more efficient than conventional cooling method. It reduces annual global warming potential by 72.95%, acidification potential 98.18%, ozone depletion potential 99.6%, smog formation potential 85.71% and human toxicity potential 42.86% compare with conventional method. The study concludes that besides inhibiting corrosion, prolonging tool life, improving surface roughness of final cutting and reducing energy usage, strong alkaline water cooling is an environmentally friendly approach and has positive impact on human health.
Źródło:
Journal of Machine Engineering; 2018, 18, 1; 45-60
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The efficiency of waste hot water utilisation to improve the temperature conditions for growing plants
Autorzy:
Turcheniuk, Vasil
Rokochinskiy, Anatoliy
Kuzmych, Lyudmyla
Volk, Pavlo
Koptyuk, Roman
Romanyuk, Ivan
Voropay, Galyna
Powiązania:
https://bibliotekanauki.pl/articles/2174361.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
cooling
recycling
soil heating
soil temperature
waste water heat
water regime
Opis:
One of the rational ways of energy saving is to use the heat of wastewater from energy companies for open ground heating and cultivation crops. The most significant sources of heat are thermal and nuclear power plants that produce low-thermal waters of 28-35°C. Heating of the ground with the use of circulating warm water allows to increase temperature at all points of the soil profile. The maximum thermal effect from heating ground is observed at the depth of pipe heaters (7.3- 11.1°C). Ground heating allows to extend the growing season for crops by 3-4 weeks, which can expedite harvesting and thus maximise the harvest. In natural moisture conditions, ground heating does not lead to significant reduction of moisture reserves in the active layer throughout the growing period. There is a redistribution of moisture in a soil profile. It decreases in the zone of pipe heaters and redistributes toward the top. The formation of the nutrient regime changes, the content of mobile phosphorus and potassium, and nitrate nitrogen increases, whereas the content of ammonia nitrogen is reduced. Ground heating is a new special heat reclamation technique. It allows not only to control temperature of the agricultural crop environment, but also to dissipate heat in the ground, and promote the utilisation of waste heat and the stabilisation of the environment.
Źródło:
Journal of Water and Land Development; 2022, 54; 94--100
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Technological System for Using Waste Warm Water from Energy Facilities for Effective Agriculture
Autorzy:
Turcheniuk, Vasil
Rokochinskiy, Anatoliy
Kuzmych, Lyudmyla
Volk, Pavlo
Koptyuk, Roman
Powiązania:
https://bibliotekanauki.pl/articles/2097754.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
waste water heat
soil temperature
soil heating
water regime
recycling
cooling
Opis:
The waste warm waters from power plants, owing to their temperature regime (25–38°C) and the volumes of discharge, allow for their use for heating of open ground areas in agriculture. Underground heating by such water is a new, special heat and irrigation method which enables not only purposeful regulation of temperature conditions of the crop growing environment, but also dissipates heat in the soil, thus cooling the water for its reuse. This makes it possible to reduce the thermal pollution of water sources.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2022, 69, 1; 13-25
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Coolant Water Flow Rate and Temperature Underside Cooling Slope on Solidification with Microstructure and Mechanical Properties of Casted AZ91 Mg Alloy
Autorzy:
Sahu, Sambeet
Kund, Nirmal
Powiązania:
https://bibliotekanauki.pl/articles/28099567.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
coolant water flow rate
coolant water temperature
cooling slope
microstructure
mechanical properties
Opis:
Present study describes about the effect of coolant water flow rate and coolant water temperature underside cooling slope on structural characteristics of casted AZ91 Mg alloy. Here, over the cooling slope, hot melt flows from top to bottom. Additionally, under the cooling slope, coolant water flows from bottom to top. Slurry gets obtained at bottom of cooling slope by pouring AZ91 Mg melt from top of the slope. Coolant water flow rate with coolant water temperature underside cooling slope warrant necessary solidification and shear to obtain AZ91 Mg slurry. Specifically, slurry at 5 different coolant water flow rates (4, 6, 8, 10, 12 lpm) and at 5 different coolant water temperatures (15, 20, 25, 30, 35°C) underside cooling slope are delivered inside metal mould. Modest coolant water flow rate of 8 lpm with coolant water temperature of 25°C (underside cooling slope) results fairly modest solidification that would enormously contribute towards enhanced structural characteristics. As, quite smaller/bigger coolant water flow rate/temperature underside cooling slope would reason shearing that causes inferior structural characteristics. Ultimately, favoured microstructure was realized at 8 lpm coolant water flow rate and 25°C coolant water temperature underside cooling slope with grain size, shape factor, primary α-phase fraction and grain density of 63 µm, 0.71, 0.68 and 198, respectively. Correspondingly, superior mechanical properties was realized at 8 lpm coolant water flow rate and 25°C coolant water temperature underside cooling slope with tensile strength, elongation, yield strength and hardness of 250 MPa, 8%, 192 MPa and 80 HV, respectively.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 2; 673--680
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pressure agglomeration of plant materials - technological and technical innovations. Part 3. A new solution for the stabilizing and cooling track for briquettes
Ciśnieniowa aglomeracja materiałów roślinnych - innowacje technologiczno-techniczne. Cz. 3. Nowe rozwiązanie toru stabilizująco-chłodzącego dla brykietów
Autorzy:
Obidziński, S.
Hejft, R.
Wszeborowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/337335.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
briquetting
cooling
stabilizing and cooling track
water jacket
brykietowanie
chłodzenie
tor stabilizująco-chłodzący
płaszcz wodny
Opis:
This paper presents a new prototype solution for the stabilizing and cooling track for briquettes from plant materials that enables a more intensive process of briquette cooling; at the same time, its design does not differ significantly from the existing ones. As a cooling factor, the designed stabilizing and cooling track uses, in addition to air, water flowing in the water jackets that surround the briquette. In the track’s design, a system of briquette press by means of a movable upper jacket equipped with a lever pressure system was used. Owing to the use of a counter-flowing cooling medium (water), the track’s construction allows to obtain good cooling conditions and does not cause briquette damage.
W pracy przedstawiono nowe prototypowe rozwiązanie toru stabilizująco-chłodzącego dla brykietów z materiałów roślinnych, który pozwala na bardziej intensywny proces chłodzenia brykietu, a jednocześnie jego konstrukcja nie odbiega znacząco od istniejących konstrukcji. Zaprojektowany tor stabilizująco- chłodzący jako czynnik chłodniczy, oprócz powietrza, wykorzystuje wodę płynącą w płaszczach wodnych, okalających brykiet. W konstrukcji toru uwzględniono system docisku brykietu za pomocą ruchomego płaszcza górnego, wyposażonego w dźwigniowy system docisku. Dzięki zastosowaniu przeciwprądowego przepływu czynnika chłodzącego (wody), zaprojektowany tor pozwala na osiągnięcie dobrych warunków chłodzenia i nie doprowadza do uszkadzania brykietu.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2016, 61, 1; 56-60
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Waste Heat Recovery from Servers Using an Air to Water Heat Pump
Autorzy:
Lipiński, Seweryn
Duda, Michał
Górski, D.
Powiązania:
https://bibliotekanauki.pl/articles/2069738.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
air-water heat pump
server cooling
waste heat
heat recovery
domestic hot water
Opis:
The analysis of advisability and profitability of using an air to water heat pump for the purpose of waste heat recovery from servers being used as cryptocurrency mining rigs, was performed. To carry out such an analysis, the cooling unit of the computing server was connected to the heat pump, and the entire system was adequately equipped with devices measuring parameters of the process. Performed experiments proves that the heat pump coefficient of performance (COP) reaches satisfactory values (i.e., an average of 4.21), what is the result of stable and high-temperature source of heat at the pump inlet (i.e., in the range of 29.9-34.1). Economic analysis shows a significant reduction in the cost of heating domestic hot water (by nearly 59-61%). The main conclusion which can be drawn from the paper, is that in a case of having a waste heat source in a form of a server or similar, it is advisable to consider the purchase of air-to-water heat pump for the purpose of domestic hot water heating.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2021, 24(1); 105--113
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Water Mist Cooling of Casting Die on the Solidification, Microstructure and Properties of AlSi20 Alloy
Autorzy:
Władysiak, R.
Kozuń, A.
Pacyniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/353825.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
silicon dendrites
casting die cooling
water mist
hypereutectic Al-Si alloy
Opis:
Unmodified AlSi20 alloy were casted at the research station, allowing for sequential multipoint cooling using a dedicated computer- controlled program. This method allows for the formation of the microstructure of hypereutectic AlSi20 alloy and also increases hardness. Primary silicon dendrites were found in the microstructure of cooled samples. Based on these dendrites, the formation of primary silicon particles is explained. Cooling of casting die with a water mist stream causes changes in solidification, which leads to expansion of the boundary layer with columnar crystals and shrinkage of the core zone with equiaxed crystals. It also causes more regular hardness distribution around pre-eutectic Si crystals, which can lead to tensile strength and machinability improvement.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 187-194
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Safety conditions in dynamic IT examinations of rheumatoid arthritis lesions
Warunki BHP w badaniach zmian w reumatoidalnym zapaleniu stawów za pomocą termografii dynamicznej
Autorzy:
Wasilewska, A.
Pauk, J.
Powiązania:
https://bibliotekanauki.pl/articles/270674.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
termografia w podczerwieni
chłodzenie
woda z lodem
infrared thermography
cooling
ice water
Opis:
Purpose of the article: Human skin temperature distribution is a source of clinically relevant information about tissue pathological process and can be observed with the use of non-contact ad non-invasive measuring technique named infrared thermography (IT). The aim of the study is to establish dynamic IT measurement safety conditions in RA examination in order to prepare the refined study protocol which provides for extracting the most reliable diagnostic thermal data. Experimental part: Thirty participants (20% of males) with diagnosed RA were included in this study. The protocol consisted in registration of thermal recovery processes after immersing left and right foot separately in ice water of less than 0 Celsius degrees. Cooling procedure included immersing left and right foot separately in ice water for 5 seconds. Separate recordings of left and right foot temperature changes were performed for 3 minute periods. The following joint temperatures were measured: ankle joint and 5 metatarsophalangeal joints. Conclusions: Difference between the moment right after immersion and the moment after 3-minute recovery appeared to be the lowest in two different patients’ ankle joints. These results suggest that the slowest rewarming rate occurs in the area of ankle joint.
Cel artykułu: Rozkład temperatury skóry ludzkiej stanowi źródło istotnej klinicznie informacji o patologicznym procesie toczącym się w tkance i można go obserwować za pomocą bezkontaktowej oraz nieinwazyjnej techniki pomiarowej zwanej termografią w podczerwieni (IT). Celem artykułu jest ustanowienie warunków bezpieczeństwa pomiaru za pomocą termografii dynamicznej w badaniach reumatoidalnego zapalenia stawów w celu przygotowania udoskonalonego protokołu badawczego, który zapewnia wydobycie najbardziej istotnych diagnostycznych danych termicznych. Część eksperymentalna: Trzydziestu uczestników (20% mężczyzn) ze zdiagnozowanym RZS zostało włączonych do badania. Protokół uwzględniał rejestrację termicznego powrotu do stanu wyjściowego po zanurzeniu oddzielnie lewej i prawej stopy w wodzie z lodem o temperaturze mniejszej niż 0°C. Procedura chłodzenia polegała na oddzielnym zanurzeniu lewej i prawej stopy w wodzie z lodem na 5 sekund. Wykonano oddzielne 3-minutowe nagrania zmian temperatur lewej i prawej stopy. Zmierzono temperatury następujących stawów: stawu skokowo-goleniowego oraz stawów śródstopnopaliczkowych. Wnioski: Różnica pomiędzy momentem bezpośrednio po zanurzeniu a momentem po 3-minutowej rejestracji okazała się być najniższa w stawach skokowo-goleniowych u dwóch pacjentów. Te wyniki sugerują, że najwolniejsze tempo ponownego nagrzewania występuje w obszarze stawu skokowego.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 3; 205-214
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kształtowanie mikrostruktury i właściwości odlewów siluminowych w formach chłodzonych mgłą wodną
Shaping the microstructure and properties of silumin castings in molds cooled with water mist
Autorzy:
Władysiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/391622.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
odlewanie kokilowe
silumin AlSi11
chłodzenie mgłą wodną
sterowanie komputerowe
mikrostruktura
właściwości mechaniczne
die casting
AlSi11 silumin
water mist cooling
computer control
microstructure
mechanical properties
Opis:
W pracy przedstawiono możliwości otrzymywania wysokojakościowych odlewów siluminowych o podwyższonych właściwościach mechanicznych. Zapewnia je zastosowany system wielopunktowego chłodzenia formy mgłą wodną, zarządzany za pomocą dedykowanego komputerowego programu sterującego.
The paper presents the possibility of obtaining highquality silumin castings with enhanced mechanical properties. It ensures the effective use of the multipoint water mist cooling system which is managed by a dedicated computer program.
Źródło:
Prace Instytutu Odlewnictwa; 2014, T. 54, nr 3, 3; 21-28
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model matematyczny odprowadzania ciepła w instalacji chłodzenia wodą wolnoobrotowego silnika okrętowego
A Mathematical Model for the Heat Exchange Process in a Low-Speed Diesel Engine
Autorzy:
Stachowiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/359704.pdf
Data publikacji:
2004
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
modelowanie matematyczne
instalacja chłodzenia wolnoobrotowego silnika okrętowego
bilans energii
symulacja komputerowa
EXPLO-SHIP 2004
mathematical modelling
fresh water cooling system of a low-speed diesel engine
energy balance
computer simulation
Opis:
Przedstawiono matematyczny model procesu chłodzenia wolnoobrotowego silnika okrętowego realizowany przez instalację chłodzenia wodą słodką. Model matematyczny obejmuje zarówno stany pracy silnika ustalone, jak i nieustalone. Wykorzystując przedstawiony model, wykonano program symulacyjny prezentujący proces chłodzenia silnika.
This paper presents a mathematical model for the heat exchange process in a fresh water-cooling system of a low-speed diesel engine. The model describes both stationary and dynamic engine operating conditions. The model is applied in simulation of the engine cooling process. Results of the simulation are discussed.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2004, 1 (73); 479-488
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure of AlSi20 Alloy in Heat Treated Die Casting
Autorzy:
Władysiak, R.
Kozuń, A.
Powiązania:
https://bibliotekanauki.pl/articles/382310.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innovative foundry technology
innovative foundry material
die casting
water mist cooling
hypereutectic silumin
microstructure
innowacyjna technologia odlewnicza
innowacyjny materiał odlewniczy
odlewanie ciśnieniowe
chłodzenie mgłą wodną
silumin nadeutektyczny
mikrostruktura
Opis:
The work is a continuation of research on the use of water mist cooling in order to increase efficiency of die-casting aluminum alloys using multipoint water mist cooling system. The paper presents results of investigation on crystallization process and microstructure of synthetic hypereutectic AlSi20 alloy. Casts were made in permanent mold cooled a with water mist stream. The study was conducted for unmodified AlSi20 alloy and a modified one with phosphorus, titanium and boron on the research station allowing sequential multipoint cooling using a dedicated program of computer control. The study demonstrated that the use of mold cooled with water mist stream and solution heat treatment allows in wide range for the formation of the microstructure of hypereutectic silumins. It leads to the growth of microstructure refinement and spheroidizing of phases in the casting.
Źródło:
Archives of Foundry Engineering; 2015, 15, 1; 113-118
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effective Water Vapour Permeability of Wet Wool Fabric and Blended Fabrics
Efektywna przepuszczalność pary wodnej tkanin wełnianych i mieszankowych będących w stanie mokrym
Autorzy:
Bogusławska-Bączek, M
Hes, L
Powiązania:
https://bibliotekanauki.pl/articles/232945.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
water vapour permeability
Permetest
wet fabrics
cooling
heat flow
przepuszczalność pary wodnej
tkaniny mieszane
mokre tkaniny
Opis:
The water vapour permeability of fabrics is one of the most important factors determining wearer comfort. Contrary to commonly accepted theories, outerwear is often used in a wet state, which has an influence on their properties. However, common standard measuring instruments mostly do not enable reliable measurement of wet fabrics due to the long time of measurement, during which the fabrics get dry. This paper presents the fast instrument - Permetest, which provides reliable measurement of the water vapour permeability of fabrics in a dry and wet state. By means of the instrument, the relative and effective water vapour permeability of different wool fabrics in a dry and wet state were determined and the results discussed. The main contribution of the measurement was the determination of the exact ratio between the level of heat flux density of the heat flow penetrating the wet fabric, having a cooling effect, and that of the heat flux density of the heat flow caused by moisture evaporation from the fabric surface, also having a cooling effect.
Przepuszczalność pary wodnej materiałów włókienniczych jest jednym z najważniejszych czynników wpływających na komfort użytkownika wyrobów odzieżowych. W przeciwieństwie do powszechnie uznanych teorii, odzież często użytkowana jest w stanie mokrym, co w istotny sposób wpływa na jej właściwości i komfort użytkowy. Tym czasem, większość powszechnie stosowanych przyrządów pomiarowych nie pozwala na przeprowadzenie wiarygodnych pomiarów właściwości tkanin będących w stanie mokrym. Wynika to ze zbyt długiego czasu pomiaru, podczas którego zmienia się zawartość wilgoci w materiałach włókienniczych. W niniejszym artykule przedstawione zostały badania przepuszczalności pary wodnej, w których wykorzystano urządzenie pomiarowe - Permetest, wykonujące pomiary w sposób szybki, zapewniając w ten sposób rzetelny pomiar przepuszczalności pary wodnej materiału włókienniczego zarówno w stanie suchym, jak i mokrym. W badaniach określona została względna i efektywna przepuszczalności pary wodnej tkanin wełnianych i mieszankowych, będących w stanie suchym oraz w różnych stanach absorpcji wilgoci. Głównym celem niniejszych badań było ustalenie współczynnika korelacji między poziomem strumienia odprowadzającego ciepło z materiału mokrego, a poziomem strumienia odprowadzającego ciepło, powstałego w wyniku odparowania wilgoci z powierzchni materiału. Dodatkowo w badaniach przedstawiono wpływ składu surowcowego oraz i wybranych parametrów struktury budowy na względną i efektywną przepuszczalność pary wodnej badanych tkanin.
Źródło:
Fibres & Textiles in Eastern Europe; 2013, 1 (97); 67-71
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Controlling the distribution of cold water in air cooling systems of underground mines
Regulacja i sterowanie parametrami wody lodowej w instalacjach klimatyzacyjnych kopalń podziemnych
Autorzy:
Szlązak, N.
Obracaj, D.
Swolkień, J.
Piergies, K.
Powiązania:
https://bibliotekanauki.pl/articles/219050.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń podziemnych
regulacja
sterowanie
woda lodowa
chłodnice powietrza
underground mines
air cooling systems
water reticulation system
automatic control
Opis:
In Polish underground mines in which excavations are subjected to high heat load, central and group cooling systems based on indirect cooling units are implemented. Chilled water, referred to as cold water and produced in chillers, is distributed through a pipeline network to air coolers located in mining and development districts. The coolers are often moved to other locations and the pipeline network undergoes constant modification. In such a system, parameters of cold water in different branches of the pipeline network need to be controlled. The article presents the principles for controlling the cooling capacity of air coolers installed in an underground mine. Also, the authors propose automatic control of water flow rate in underground pipeline network and in particular coolers, depending on the temporary cooling load in the system. The principles of such a system, controlling cold water distribution, and the functions of its individual components are described. Finally, an example of an automatic control of water flow rate in a central cooling system currently implemented in a mine is presented.
W polskich kopalniach podziemnych o dużym obciążeniu cieplnym wyrobisk stosuje się systemy klimatyzacji grupowej i centralnej, projektowane w oparciu o urządzenia chłodnicze pośredniego działania. Wytwarzana w agregatach chłodniczych woda lodowa rozprowadzana jest siecią rurociągów do chłodnic powietrza w rejonach eksploatacyjnych i przygotowawczych. Chłodnice są często przebudowywane, a sieć rurociągów ulega ciągłej zmianie. Obieg wody w sieci rurociągów wymaga ciągłej regulacji w za kresie wymaganego natężenia przepływu wody lodowej w poszczególnych odgałęzieniach sieci rurociągów. W artykule przedstawiono zasady regulacji wydajności chłodnic powietrza. Zaproponowano układ automatycznego sterowania rozpływem wody lodowej w sieci, jaką tworzą rurociągi i chłodnice powietrza, w zależności od chwilowego zapotrzebowania mocy w chłodnicach. Omówiono zasady takiej regulacji oraz funkcje, jakie muszą spełniać poszczególne elementy układu sterowania rozpływem wody lodowej. Przedstawiono przykład wdrażanego aktualnie sterowania rozpływem wody lodowej w klimatyzacji centralnej.
Źródło:
Archives of Mining Sciences; 2016, 61, 4; 793-807
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhancement of the Brayton cycle efficiency by water or steam utilization
Autorzy:
Jesionek, K.
Chrzczonowski, A.
Ziółkowski, P.
Badur, J.
Powiązania:
https://bibliotekanauki.pl/articles/175275.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Brayton cycle
regeneration
Cheng cycle
thermodynamic analysis
gas steam turbine
computational flow mechanics
steam injection
water injection
interstage cooling
Opis:
In the paper, thermodynamic analysis of two modifications of the Brayton cycle into enhancement cycles with water or steam injection are discussed. The first one deals with a water injected gas turbine modified system with both interstage compressed air cooling and air heating (heat regeneration) before combustion chamber. The second one, mainly devoted to higher steam to air ratio, is connected with separate steam production in the heat recovery steam generator. Hence, steam utilization for the gas turbine propulsion in the Cheng cycle has been analysed. The analysis has been based on the computational flow mechanics (CFM) models of these advanced humidified systems, thanks to which, the influence of the main thermodynamic and design parameters have been examined.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2012, 124; 93-109
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Shaping the Structure and Properties of High Quality Silumin Castings in Metal Molds Cooled with Water Mist
Autorzy:
Władysiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/381548.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innovative material
casting technology
cooling
water mist
permanent mould casting
materiał innowacyjny
technologia odlewnicza
chłodzenie
mgła wodna
forma odlewnicza
Opis:
The paper presents some aspects of the theory and technology of high quality silumin castings in metal molds cooled pointed with water mist stream. The results of the work relate to improvement of the properties of silumin casts by affecting the cooling of the liquid silumin in gravity cast in metal mold and the possibility of controlling the solidification and crystallization of the casting. The high efficiency required from the cooling system is a consequence of an optimal selection of parameters of the generated mist and the maximum use of the phenomenon of water droplets evaporation on the surface of the cooled mold. The study showed that sequential spot cooling with use of water mist, characterized by a wide range of control means and a high maximum heat transfer efficiency, enables to control the flow of heat between the casting and the mold and it allows for a layered solidification leading to the realization of the entire cast solidification in the expected way: directional or simultaneous. Consequently, the results are: improvement of the quality of the castings as a result of the elimination of defects and significant reduction in shrinkage porosity in the casting, an increase of the homogeneity and fineness of the microstructure, about 25% increase in the mechanical properties.
Źródło:
Archives of Foundry Engineering; 2013, 13, 2 spec.; 98-105
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zelowanie modelowych ukladow k-karagenian-skrobia w mleku oraz roztworze koncentratu bialek serwatkowych
Autorzy:
Mleko, S
Powiązania:
https://bibliotekanauki.pl/articles/827117.pdf
Data publikacji:
1999
Wydawca:
Polskie Towarzystwo Technologów Żywności
Tematy:
ogrzewanie
bialka serwatkowe
zelowanie
karageny
lepkosc
mleko
woda
skrobia
chlodzenie
heating
whey protein
gelation
carrageenan
viscosity
milk
water
starch
cooling
Opis:
Celem pracy było zbadanie lepkości modelowych układów ĸ-karagenianu i skrobi w wodzie, mleku oraz roztworze koncentratu białek serwatkowych. Prześledzono zmiany lepkości pozornej podczas ogrzewania i chłodzenia powyższych układów. Stwierdzono istnienie efektu synergicznego pomiędzy skrobią a ĸ-karagenem, wyrażającego się wzrostem lepkości w zakresie temperatur charakterystycznym dla żelowania jednej z tych substancji, przy jej stałym stężeniu, a wzrastającym stężeniu drugiego składnika. Mieszanina ĸ-karagen/skrobia żelowała lepiej w mleku niż roztworze koncentratu białek serwatkowych, co mogło być spowodowane dużą zawartością soli mineralnych w koncentracie. Układy ĸ-karagen/skrobia charakteryzowały się wyższą lepkością w mleku i roztworze koncentratu białek serwatkowych niż w wodzie, co może świadczyć o zachodzeniu oddziaływań pomiędzy tymi substancjami a białkami mleka.
The objective of this study was to investigate changes in apparent viscosity of model ĸ- carrageenan/starch systems in milk or whey protein concentrate (WPC) solution. A synergistic effect was found for starch and ĸ-carrageenan, as viscosity at the temperature characteristic for one gelling agent increased, when concentration of this agent was constant and concentration of another agent increased. Mixture of ĸ-carrageenan/starch yields better gels in milk than whey protein concentrate, which could be caused by high mineral content in investigated WPC. ĸ-carrageenan/starch systems had higher viscosity in milk or WPC, which could indicate milk proteins - ĸ-carrageenan - starch interactions.
Źródło:
Żywność Nauka Technologia Jakość; 1999, 06, 3; 48-54
1425-6959
Pojawia się w:
Żywność Nauka Technologia Jakość
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer control the cooling process in permanent mold casting of Al-Si alloy
Sterowanie komputerowe procesem chłodzenia formy w odlewaniu kokilowym siluminów
Autorzy:
Władysiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/353901.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innovative materials & casting technologies
cooling
water mist
Al-Si alloy
innowacyjne materiały i technologie odlewnicze
chłodzenie
mgła wodna
stop Al-Si
Opis:
The paper presents the test results of a computerized control system the sequential cooling process of permanent mold with use of water mist in the gravity die casting process. It describes the process for preparing high-quality casts made of AlSi7Mg alloy that achieves enhanced mechanical properties. A scheme of developed device and drivers for selected methods of sequence cooling for manufacturing of castings made in permanent steel mold was presented here. Also the microstructure and mechanical properties of received aluminium casts were described. It was shown that the use of a computer system to control the water mist cooling point of the mold not only accelerates the cooling of the cast and the gravity die casting cycle shortens, but also it has a positive effect on the microstructure and mechanical properties of castings made of unmodified AlSi7Mg alloy in a raw state.
W pracy przedstawiono wyniki badań komputerowego systemu sterowania sekwencyjnym chłodzeniem kokili mgła wodna w odlewaniu grawitacyjnym. Opisano proces otrzymywania wysokojakościowych odlewów z siluminu AlSi7Mg o podwyższonych właściwościach mechanicznych. Przedstawiono opracowane urządzenie, programy sterujące dla zadanych metod wytwarzania odlewów kokilowych i sekwencji chłodzenia. Przedstawiono mikrostrukturę i własności mechaniczne otrzymanych odlewów siluminowych. W pracy wykazano, że zastosowanie systemu komputerowego do sterowania chłodzeniem punktowego mgła wodna nie tylko przyspiesza stygnięcie odlewu i skraca cykl odlewania kokilowego, ale również korzystnie wpływa na mikrostrukturę i własności mechaniczne odlewów z niemodyfikowanego siluminu AlSi7Mg w stanie surowym.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 3; 977-980
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conceptual adsorption system of cooling and heating supplied by solar energy
Autorzy:
Turski, M.
Powiązania:
https://bibliotekanauki.pl/articles/952679.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
solar cooling
solar heating
solar energy
adsorption chiller
adsorption ice water
generator
chłodzenie słoneczne
ogrzewanie słoneczne
energia słoneczna
adsorpcja wody lodowej
Opis:
This paper presents the possibility of reducing the demand for nonrenewable primary energy for buildings using a new conceptual adsorption system of cooling and heating supplied by solar energy. Moreover, the aim of this study is to shorten the payback time of investment in the standard adsorption cooling system through its integration with the heating system. Research has been carried out for an energy-efficient medium-sized single-family building with a floor area of 140 m 2 and a heat load of 4.2 kW and cold load of 4.41 kW. It has been shown that the use of an adsorption system of cooling and heating supplied by solar energy decreased the demand for nonrenewable primary energy by about 66% compared to the standard building that meets the current requirements.
Źródło:
Chemical and Process Engineering; 2016, 37, 2; 293-304
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Crystallization Process of Intensive Cooled AlSi20CuNiCoMg Alloy
Autorzy:
Władysiak, R.
Kozuń, A.
Dębowska, K.
Pacyniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/379541.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innovative foundry technologies
innovative foundry materials
casting die cooling
water mist
silumin
innowacyjne technologie odlewnicze
innowacyjne materiały odlewnicze
odlewanie kokilowe
mgła wodna
Opis:
The work is a continuation of research concerning the influence of intensive cooling of permanent mold in order to increase the casting efficiency of aluminium alloys using the multipoint water mist cooling system. The paper presents results of investigation of crystallization process and microstructure of multicomponent synthetic hypereutectic alloy AlSi20CuNiCoMg. The study was conducted for unmodified silumin on the research station allowing the cooling of the special permanent sampler using a program of computer control. Furthermore the study used a thermal imaging camera to analyze the solidification process of multicomponent alloy. The study demonstrated that the use of mold cooled with water mist stream allows in wide range to form the microstructure of hypereutectic multicomponent silumin. It leads to higher homogeneity of microstructure and refinement of crystallizing phases of casting.
Źródło:
Archives of Foundry Engineering; 2017, 17, 2; 137-144
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesów fizykochemicznych do usuwania zanieczyszczeń z eksploatowanych samochodowych płynów chłodzących
Application of the physic-chemical processes for the removal of contamination from used automotive cooling liquids
Autorzy:
Molenda, J.
Sadowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/257275.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
samochoód
płyn chłodzący
roztwor wodno-glikolowy
właściwości użytkowe
oczyszczanie
eksploatacja ekologiczna
car
automotive cooling liquid
glycol-water solution
functional properties
purification
ecological use
Opis:
W artykule przedstawiono rezultaty prac w zakresie recyklingu samochodowych płynów chłodzących. Celem pracy był dobór odpowiednich operacji jednostkowych, które zestawione w sekwencję technologiczną pozwoliły na efektywne usunięcie zanieczyszczeń z wyeksploatowanych samochodowych płynów chłodzących, a tym samym wydłużenie ich cyklu życia i ograniczenie balastu odpadów obciążających środowisko naturalne. Najlepsze efekty uzyskano podczas oczyszczania eksploatowanych samochodowych płynów chłodzących na drodze wirowania i mikrofiltracji oraz sorpcji. Przeprowadzone badania instrumentalne oczyszczonych produktów, zrealizowane technikami spektralnymi (EDS, XRF, FTIR), wykazały skuteczność zastosowanych metod w usuwaniu zarówno zanieczyszczeń stałych, jak też rozpuszczalnych w kompozycjach wodno-glikolowych.
The paper presents the results of the research concerning the recycling of automotive cooling liquids. It indicates the means of reusing purified liquids in automotive cooling systems or applying them as components of new liquids. This work aims at the selection of suitable unit operations leading to effective removal of the contamination. Such activity promotes the limitation of pollutants in the natural environment. The best results were obtained during centrifugation, microfiltration and sorption of used automotive cooling liquids. Purified products were investigated by means of spectral techniques (EDS, XRF, FTIR). It has been concluded that these methods were effective in the removal of solids as well as contamination dissolved in glycol-water compositions.
Źródło:
Problemy Eksploatacji; 2008, 2; 105-114
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klasyfikacja stanu przybrzeżnych wód morskich na Ukrainie na przykładzie Morza Azowskiego w rejonie Mariupola
Classification of the State of narine coastal waters in Ukraine in the example of the Sea of Azov in the Mariupol Region
Autorzy:
Neverova-Dziopak, E.
Dan, O.
Powiązania:
https://bibliotekanauki.pl/articles/1203874.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
Morze Azowskie
huta
ścieki chłodnicze
ścieki technologiczne
ocena stanu wód
ocena oddziaływania na środowisko
wskaźnik jakości wody
wskaźnik zanieczyszczenia wody
Sea of Azov
steelworks
cooling wastewater
technological waste water
water status assessment
environmental impact assessment
Water Quality Index
Water Pollution Index
Integrated Ecological State Index
Opis:
Morze Azowskie jest najmniejszym i najpłytszym morzem na świecie o małym zasoleniu. Takie właściwości powodują jego podatność na degradację pod wpływem działalności antropogenicznej. Jednym z głównych źródeł zanieczyszczeń Morza Azowskiego jest huta „Azovstal” w Mariupolu (Ukraina). Negatywny wpływ huty jest związany przede wszystkim z dużą ilością odprowadzanych do morza ścieków chłodniczych i technologicznych. W pracy przedstawiono wyniki oceny oddziaływania ścieków z huty na jakość wody morskiej i sytuację ekologiczną w strefie ich odprowadzania, dokonanej na podstawie metod stosowanych w Ukrainie oraz obowiązujących standardów jakości wód powierzchniowych. Kompleksową ocenę dokonano na podstawie wartości trzech wskaźników jakości wody morskiej – wskaźnika jakości wody (WJW), wskaźnika zanieczyszczenia wody (WZW) oraz zintegrowanego wskaźnika stanu ekologicznego (ZWSE), a także z uwzględnieniem tak zwanej zasady sumowania. Na podstawie wyników przeprowadzonej oceny wykazano, że odprowadzanie ścieków z huty „Azovstal” prowadzi do znacznego wzrostu stopnia zanieczyszczenia wód w strefie przybrzeżnej Morza Azowskiego, co stanowi zagrożenie ekosystemu morskiego i ogranicza wszystkie rodzaje użytkowania wody.
The Sea of Azov is the smallest and shallowest sea in the world with low salinity. Such properties determine its susceptibility to degradation due to anthropogenic activities. The Azovstal Iron & Steel Works in Mariupol (Ukraine) is one of the main sources of pollution of the Azov Sea. Adverse impact of the steelworks is associated primarily with the large amount of technological and cooling wastewater discharged into the sea. The paper presents the impact assessment results of wastewater discharge on the sea water quality and the ecological conditions in the discharge zone. The assessment was performed using local Ukrainian methodologies as well as applicable surface water quality standards. The comprehensive assessment was based on the three numerical integrated indicators of sea water quality: the Water Quality Index (WJW), the Water Pollution Index (WZW), the Integrated Ecological State Index (ZWSE), and the so called principle of aggregation. Based on the assessment results it was demonstrated that the wastewater discharge from the Azovstal Iron & Steel Works leads to significant increase in water pollution in the coastal zone which brings threat to the marine ecosystem and limits all types of water consumption.
Źródło:
Ochrona Środowiska; 2018, 40, 3; 29-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Water Mist Cooling on Microstructure of Hypereutectic Al-Si Alloy
Autorzy:
Władysiak, R.
Kozuń, A.
Powiązania:
https://bibliotekanauki.pl/articles/382973.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innovative foundry technologies
innovative foundry materials
casting die cooling
water mist
hypereutectic silumin
microstructure
innowacyjne technologie odlewnicze
innowacyjne materiały odlewnicze
chłodzenie
silumin nadeutektyczny
mikrostruktura
Opis:
The work is a continuation of research on the use water mist cooling in order to increase efficiency of die-casting aluminum alloys using multipoint water mist cooling system. The paper presents results of investigation of crystallization process and microstructure of synthetic hypereutectic AlSi20 alloy. Casts were made in permanent mold cooled with water mist stream. The study was conducted for unmodified AlSi20 alloy and modified with phosphorus, titanium and boron on the research station allowing sequential multipoint cooling using a dedicated program of computer control. The study demonstrated that the use of mold cooled with water mist stream allows the formation of the microstructure of hypereutectic silumins. A wide range of solidification temperature of hypereutectic silumins increases the potential impact of changes in the cooling rate on a size, a number and a morphology of preeutectic silicon and eutectic α+β (Al+Si).
Źródło:
Archives of Foundry Engineering; 2014, 14, 3; 117-122
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Casting Die Cooling on Solidification Process and Microstructure of Hypereutectic Al-Si Alloy
Autorzy:
Władysiak, R.
Kozuń, A.
Pacyniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/380676.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innovative foundry technology
innovative foundry material
casting die cooling
water mist
hypereutectic silumin
innowacyjna technologia odlewnicza
innowacyjny materiał odlewniczy
odlewanie kokilowe
mgła wodna
silumin nadeutektyczny
Opis:
The work is a continuation of research concerning the influence of intensive cooling of permanent mold in order to increase the casting efficiency of aluminium alloys using the multipoint water mist cooling system. The paper presents results of investigation of crystallization process and microstructure of synthetic hypereutectic alloys: AlSi15 and AlSi19. Casts were made in permanent mold cooled with water mist stream. The study was conducted for unmodified silumins on the research station allowing the cooling of the special permanent probe using a program of computer control. Furthermore the study used a thermal imaging camera to analyze the solidification process of hypereutectic silumins. The study demonstrated that the use of mold cooled with water mist stream allows in wide range the formation of the microstructure of hypereutectic silumins. It leads to higher homogeneity of microstructure and refinement of crystallizing phases and also it increases subsequently the mechanical properties of casting.
Źródło:
Archives of Foundry Engineering; 2016, 16, 4; 175-180
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coolant pump for compression-ignition aircraft engine
Autorzy:
Gęca, Michał Jan
Pietrykowski, Konrad
Barański, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/133232.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
diesel engine
opposed-piston engine
aircraft propulsion system
cooling system
water pump
silnik wysokoprężny
silnik o tłokach przeciwbieżnych
układ napędowy samolotu
układ chłodzenia
pompa wody
Opis:
The article presents an analysis of the design of cooling liquid pumps for a compression-ignition aircraft engine. A 100 kW twin-charged, two-stroke, liquid-cooled engine has 3 cylinders and 6 opposed-pistons. In the first part of the study, the amount of heat needed to be removed by the cooling system was estimated to obtain the required volumetric flow rate. Then, the design of automotive cooling liquid pumps for compression-ignition engines with a Common Rail power supply system and power of about 100 kW was analyzed. The aim of the analysis was to select a suitable pump for applications in the aircraft compression-ignition engine. 5 constructions of different shape, diameter and width of the working rotor were selected. The pressure and volume flow rate were determined for a given rotational speed of the pump on a specially built stand. The operation maps of individual pumps were created to select the most efficient types of pumps.
Źródło:
Combustion Engines; 2019, 58, 4; 52-57
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure of water mist stream and its impact on cooling efficiency of casting die
Autorzy:
Władysiak, R.
Budzyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/382910.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innowacyjne technologie odlewnicze
innowacyjne materiały odlewnicze
odlewanie kokilowe
mgła wodna
mikrostruktura
strumień ciepła
innovative foundry technologies
innovative foundry material
casting die cooling
water mist
microstructure
heat flux
Opis:
The work is a continuation of research on the use water mist cooling in order to increase efficiency of die-casting aluminum alloys. The paper presents results of research and analysis process, spraying water and generated a stream of water mist, the effect of the type of nozzle, the nozzle size and shape of the emitting of the water mist on the wall surface of casting die on the microstructure and geometry of water mist stream and cooling efficiency. Tests were used to perform high-speed camera to record video in the visible and infrared camera. Results were used to develop a computerized image analysis and statistical analysis. The study showed that there are statistical relationships between water and air flow and geometry of the nozzle and nozzle emitting a stream of microstructure parameters of water mist and heat the incoming stream. These relationships are described mathematical models that allow you to control the generating of adequate stream of water mist and a further consequence, the cooling efficiency of casting die.
Źródło:
Archives of Foundry Engineering; 2012, 12, 2; 251-260
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of multipoint sequential water mist cooling of casting die on microstructure and mechanical properties of AlSi11 alloy
Autorzy:
Władysiak, R.
Powiązania:
https://bibliotekanauki.pl/articles/380430.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
innowacyjne technologie odlewnicze
innowacyjne materiały odlewnicze
odlewanie kokilowe
mgła wodna
AlSi11
mikrostruktura
właściwości mechaniczne
innovative foundry technologies
innovative foundry materials
casting die cooling
water mist
microstructure
mechanical properties
Opis:
The work is a continuation of research on the use of water mist cooling in order to increase efficiency of the die-casting process for aluminum alloys. The paper describes the multipoint sequential cooling system of the casting die and its computer control and monitoring. It also includes results of the tests and analysis of cooling methods during making of the casting. These methods differ from each other in the sequence of casting die cooling and cause effective changes in microstructure and mechanical properties of castings made of AlSi11 alloy. The study demonstrated that the use of multipoint sequential cooling with water mist affects the microstructure refinement and reduces the segregation in the cast as well as more than by 20% increases the mechanical properties of castings in the rough state. The study also demonstrates that the sequential cooling of casting die accelerates the cooling of the casting and shortens die-casting cycle.
Źródło:
Archives of Foundry Engineering; 2012, 12, 4; 145-150
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-49 z 49

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies