Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Constructed Wetland" wg kryterium: Temat


Wyświetlanie 1-41 z 41
Tytuł:
Influence of bio-preparation on wastewater purification process in constructed wetlands
Autorzy:
Puchlik, M.
Ignatowicz, K.
Dąbrowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/124937.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
biopreparation
wastewater
Opis:
Technological system of analyzed wastewater treatment plant is in part a biological bed of soil-reed in parallel arrangement. Unusual application is the application of two independent purification lines where in the second line, a bio-preparation is additionally dosed. The constructed wetland provides high removal of organic compounds expressed as BOD5 and COD, as well as reducing the concentration of ammonia nitrogen and phosphates. This indicates a high performance of such a sewage treatment plant.
Źródło:
Journal of Ecological Engineering; 2015, 16, 1; 159-163
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of Pesticides from Wastewater by the Use of Constructed Wetlands
Autorzy:
Ignatowicz, Katarzyna
Puchlik, Monika
Łozowicki, Jakub
Powiązania:
https://bibliotekanauki.pl/articles/125196.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
organic matter
pesticides
Opis:
The purpose of the work was to determine the efficiency of domestic wastewater treatment contaminated with a mixture of pesticides at varying deposit load. The efficiency of purification in the case of eight pesticides equaled 99.8%, and the removal effect of azoxystrobin reached 93%, while that of thiachloprid – 96%. The constructed wetland ensured high removal of organic matter expressed as BOD and COD, as well as reduction in the concentration of nitrogen and phosphorus compounds. Studies showed a clear impact of the deposit load on the effectiveness of pesticide removal, BOD and COD parameters, total phosphorus, and total nitrogen.
Źródło:
Journal of Ecological Engineering; 2020, 21, 1; 219-223
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of Mesocosm to Remove Nutrients with Constructed Wetlands
Autorzy:
Timotewos, M. T.
Kassa, K.
Reddythota, D.
Powiązania:
https://bibliotekanauki.pl/articles/124119.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
horizontal subsurface flow wetland
Typha
nutrients
Opis:
Oxidizing bacteria in the roots of the plant has a unique ability of absorbing pollutants in the wastewater, thus they considered as a useful method for wastewater treatment. Using three plants, namely Typha, Phragmites australis, and Scirpus, we performed a series of mesocosms experiments in Arba Minch, Ethiopia for the removal of nutrients by constructed wetlands. We observed that the nutrients reached the removal efficiencies of 99.1% for Typha plant, has better removal efficiency than Phragmites australis and Scirpus. The results explore the oxidizing bacteria activity in different plants and that led to enhance the removal efficiency of pollutants in wastewater.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 42-51
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Textile Wastewater Treated by Constructed Wetlands – A Critical Review
Autorzy:
Hussein, Amjad
Powiązania:
https://bibliotekanauki.pl/articles/24201781.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
azo dye
constructed wetland
textile wastewater
treatment
Opis:
Textile industries are among the most environmentally unsustainable businesses, releasing large amounts of effluent that endangers ecosystem health. Constructed wetlands (CWs) are low-cost eco-technical treatments for industrial wastewater control. The CWs are self-contained remediation systems that do not require external energy and have basic mechanisms for pollutant removal, such as biological, chemical, and physical processes. For more than sixty years, constructed wetlands have been utilized to clean wastewater. Most applications have been developed to treat municipal or household wastewater, although CWs are now successfully used to treat a wide range of wastewater types. Constructed wetlands were also employed to treat textile industry effluents in the 1990s. The survey indicated that textile manufacturing wastewaters were treated using subsurface and surface-flow wetlands. Both horizontal and vertical flow systems have been designed within subsurface flow-created wetlands. In addition, many hybrid-built wetlands have recently been documented in the literature for textile industrial wastewater treatment. According to the survey, textile industrial wastewater is treated in constructed wetlands on all continents, and this research includes the data from 65 constructed wetlands in 21 nations worldwide. This paper examined the latest improvements and discoveries in CWs and the many types of CWs used for textile wastewater treatment. The paper also demonstrated state-of-the-art integrated technologies for improving the performance and sustainability of CWs, such as CW-MFC systems.
Źródło:
Journal of Ecological Engineering; 2023, 24, 5; 256--275
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetics of Pollutants Removal in Wetlands Influenced by Retention Time and Number of Plants Using Cyperus alternifolius
Autorzy:
Rahman, Danar Arifka
Priambodo, Eka Wahyudi
Caturputranto, Trisnadi Widyaleksono
Wahyudianto, Febri Eko
Powiązania:
https://bibliotekanauki.pl/articles/2202280.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
Cyperus alternifolius
kinetics
wastewater treatment
Opis:
Constructed wetland is considered an alternative for domestic wastewater treatment in cities. This study serves to evaluate the removal capacity and kinetics of TSS, COD, phosphate, and surfactant in domestic wastewater with several plants of Cyperus alternifolius, through the use of the constructed wetlands treatment. The overall objective of the study was to determine the ability of Cyperus alternifolius to remove water pollutants in domestic wastewater in several plants. The domestic wastewater was contacted in a batch system. The results indicated that CWs had a good performance on COD, phosphate, and surfactant with removal efficiencies of more than 80%, with a retention time of 8 days and 5 plants. However, the removal of suspended solids was found limited, as shown that the TSS removal efficiency was under 40%. The first-order equation of kinetics described the degradation of pollutants. The q1/2 values, which were defined as the average removal loading prior to the half of the pollutant concentration being removed and represented the removal capacity without limitation of pollutants concentration, were moderately increased with an addition to the number of plants.
Źródło:
Journal of Ecological Engineering; 2022, 23, 12; 37--43
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza statystyczna zawartości azotu ogólnego w złożu oczyszczalni hydrofitowej w Małyszynie
Statistical analysis of total nitrogen in the soil of constructed wetland in Małyszyn
Autorzy:
Jakubaszek, A.
Wojciech, M.
Powiązania:
https://bibliotekanauki.pl/articles/372002.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
oczyszczalnia hydrofitowa
wastewater treatment
constructed wetland
Opis:
Usuwanie związków azotu w oczyszczalniach hydrofitowych uzależnione jest od wielu czynników fizyczno-chemicznych i biochemicznych oraz warunków środowiskowych. W artykule przedstawiono opracowanie statystyczne zawartości azotu ogólnego w złożu hydrofitowym oczyszczalni. Wyniki badań materiału filtracyjnego wykazały, że największą zawartością azotu charakteryzowała się powierzchniowa warstwa gruntu do 20 cm głębokości. Kumulacja azotu ogólnego malała wraz z penetracją w głąb złoża oraz w kierunku odpływu ścieków z oczyszczalni.
Removal of nitrogen from constructed wetlands depends on many physic-chemical and biochemical conditions, deposit and environmental factors. The paper contains the results of statistical analysis the accumulation of total nitrogen in the soil. The results of the research have indicated that the highest content of nitrogen was observed in the surface layer of the soil at a depth of up to 20 cm. The content of total nitrogen has dropped with the penetration depth and towards the sewage flow from the constructed wetland.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 142 (22); 75-85
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanieczyszczenia mikrobiologiczne powietrza atmosferycznego na terenie i w otoczeniu oczyszczalni ścieków z systemem stawów napowietrznych
Microbiological contamination of atmospheric air in the constructed wetland (with aerated and stabilization ponds) and in its surrounding
Autorzy:
Gotkowska-Płachta, A.
Filipkowska, Z.
Korzeniewska, E.
Janczukowicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/338375.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bakterie
oczyszczalnie hydrofitowe
powietrze
air
bacteria
constructed wetland
Opis:
Badania powietrza atmosferycznego prowadzono na terenie i w otoczeniu hydrofitowej oczyszczalni ścieków bytowo-gospodarczych w Biesalu o przepustowości 170 m³ ·d-¹, z pięciostopniowym stawem napowietrzanym, stawem stabilizacyjnym oraz filtrem gruntowo-roślinnym o przepływie poziomym (FGR). Badano liczebność bakterii heterotroficznych psychrofilnych, psychrotrofowych i mezofilnych oraz wybranych grup fizjologicznych drobnoustrojów: z rodziny Enterobacteriaceae, rodzaju Staphylococcus i Enterococcus, gatunku Pseudomonas fluorescens, bakterii hemolizujących oraz promieniowców. Powietrze do badań pobierano w sezonach letnim, jesiennym, zimowym i wiosennym, równolegle dwoma metodami (sedymentacyjną i zderzeniową) na 6 stanowiskach usytuowanych na terenie oczyszczalni oraz na 4 usytuowanych w jej otoczeniu. Tło wyznaczano w zależności od kierunku wiatru po stronie nawietrznej w stosunku do położenia oczyszczalni. Równolegle z badaniami mikrobiologicznymi prowadzono pomiary temperatury i wilgotności powietrza oraz prędkości wiatru. Biorąc pod uwagę poszczególne grupy badanych drobnoustrojów, stwierdzono statystycznie istotne różnice ich liczebności w powietrzu pobieranym w różnych sezonach badawczych oraz różnymi metodami. Największą średnią ich liczebność stwierdzano zazwyczaj w próbkach powietrza pobieranego metodą sedymentacyjną oraz w okresie wiosennym (z wyjątkiem bakterii z rodziny Enterobacteriaceae, których maksymalną liczebność odnotowano latem i jesienią), najmniejszą natomiast zimą. Nie stwierdzono istotnych statystycznie różnic w liczebności badanych grup drobnoustrojów w powietrzu pobieranym na poszczególnych stanowiskach badawczych, jednak większą ich liczebność stwierdzano w powietrzu pobieranym w pobliżu osadnika pionowego, komory magazynowania osadu oraz sporadycznie w odległości 25 m od ogrodzenia obiektu. Uwzględniając kryteria oceny stopnia bakteriologicznego zanieczyszczenia powietrza atmosferycznego podane w normach PN-89-Z-04111/02 i prPN-Z-04111-2: 2004, badane powietrze na terenie i w otoczeniu oczyszczalni ścieków przeważnie było niezanieczyszczone lub średnio zanieczyszczone.
Atmospheric air was analysed on the premises and in the surrounding of a constructed wetland in Biesal, treating 170 m³ ·d-¹ of domestic wastewater, which operates in a system of five-stage aerated pond, stabilization pond and a reed bed with horizontal flow. The following microorganisms were assayed: heterotrophic psychrophilic, psychrotrophic and mesophilic bacteria and some physiological groups of microorganisms of the family Enterobacteriaceae, genera Staphylococcus and Enterococcus, species Pseudomonas fluorescens, haemolysing bacteria and actinomycetes. Air for the assays was sampled in summer, autumn, winter and spring, with two parallel methods (sedimentation and impact) at six sites located on the premises of the constructed wetland and at four other sites in its surrounding. The background was selected, depending on wind direction, on the windward side of the constructed wetland. The microbiological tests were accompanied by measurements of the air temperature and humidity and wind velocity. Statistical analyses of the results showed significant differences in the number of analysed groups of microorganisms in the air sampled with different methods and in different seasons. The highest mean number of microorganisms was typically determined in air samples collected with the sedimentation method and in the spring season (except for bacteria of the family Enterobacteriaceae, which were most numerous in summer and autumn) and lowest results were obtained in winter. No statistically significant differences were found between the numbers of analysed microorganisms in the air sampled at particular sampling sites, although the microorganisms occurred in higher numbers in the air collected near the vertical sedimentation tank, sludge storage tank and, sporadically, 25 m from the fence of the wastewater treatment plant. According to the norms set for bacteriological contamination of atmospheric air [PN-89-Z-04111/02, prPN-Z-04111-2], the air sampled on the premises and in the surrounding of the constructed wetland was evaluated as being unpolluted or moderately polluted.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2008, 8, 1; 83-98
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Constructed Wetlands for Treatment of Wastewater from Fruit and Vegetable Industry
Autorzy:
Puchlik, M.
Powiązania:
https://bibliotekanauki.pl/articles/123556.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
fruit and vegetable industry
organic matter
Opis:
About 2000 plants are involved in fruit and vegetable processing in Poland, they are mostly located in non-urbanized areas and without any access to sewerage and sewage treatment facilities. In 2014, they produced more than 10 hm3 of wastewater requiring treatment, which was discharged directly into surface waters or into the ground. The aim of the study was to evaluate the efficiency of the constructed wetland for treating the sewage from fruit and vegetable industry. The analyzed constructed wetland with vertical flow reveled a reduction in the value of BOD5 to 68.2%, and CODCr to 79.3%. The model was characterized by 60.2% efficiency of total phosphorus removal.
Źródło:
Journal of Ecological Engineering; 2016, 17, 1; 131-135
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of Reactive Nitrogen in Leachate Treatment in Constructed Wetlands
Autorzy:
Arliyani, Isni
Tangahu, Bieby Voijant
Mangkoedihardjo, Sarwoko
Powiązania:
https://bibliotekanauki.pl/articles/1838409.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
reactive nitrogen
performance
effects
landfill leachate
constructed wetland
Opis:
Reactive Nitrogen (Nr) is produced from natural and human activity, the use of fuel, the activities of industry, and agriculture. The Nr from agriculture is used to produce food crops, but excess Nr has an impact on the surrounding land. Landfills also generate Nr from the decomposition of waste which then releases the leachate containing Nr. This study aimed to determine the value of Nr generated by landfills, the effect of Nr on the environment, and the performance of Nr when used in Constructed Wetlands (CW). Review papers were collected from several studies and publications. Nr commonly found in leachate landfills include: NH4, NH3, NO2, and NO3. The Nr present in landfill leachate at CW can be used for proper plant development and growth, which significantly increases and enhances its quality and yield by playing an important role in the biochemical and physiological functions of plants. In addition, the content of hazardous substances in landfill leachate can also be processed using CW. This review paper discusses the effects of Nr from human activities ending up in landfills. The landfill leachate with Nr content can be used in CW for plant growth.
Źródło:
Journal of Ecological Engineering; 2021, 22, 5; 205-213
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Performance of Hybrid Constructed Wetland System for Treating the Batik Wastewater
Autorzy:
Rahmadyanti, Erina
Audina, Oktavia
Powiązania:
https://bibliotekanauki.pl/articles/123253.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
batik industry
wastewater
hybrid constructed wetland
Canna indica
Opis:
The batik industry is one of the Indonesian economic drivers. However, most of the batik industries discharge their wastewater without any prior treatment, thus endangering the environment. This research aims to investigate the ability of hybrid constructed wetlands (CWs) system using Canna indica in the batik wastewater treatment. The parameters studied were chemical oxygen demand (COD), total suspended solid (TSS), and oil and grease (FOG) with 3, 5, and 7 days of hydraulic retention time (HRT). The results indicate that the hybrid constructed wetland system using Canna indica optimally gains the COD and FOG removal efficiency on day 3 at 89.61% and 89.53%, while the TSS removal efficiency on day 5 at 98.74%. Despite the high removal efficiency, the effluent parameters remain below the standards for direct discharge into waterbodies. Therefore, further research is needed to investigate the appropriate pre-/advanced treatment to be combined with the hybrid constructed wetland in batik wastewater treatment.
Źródło:
Journal of Ecological Engineering; 2020, 21, 3; 94-103
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Constructed Wetland for Treating Runoff from the Dairy Cattle Farm Yard
Autorzy:
Rossa, Ludmiła
Urbaniak, Marek
Majewska, Zuzanna
Powiązania:
https://bibliotekanauki.pl/articles/124464.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
runoff waters
cattle farm
water quality
constructed wetland
Opis:
Constructed wetlands (CWs) are becoming a popular solution for the treatment of rainwater discharged from hardened surfaces, because their construction and maintenance does not require large expenditures. The research on the effectiveness of treating runoff from the dairy farm yard was carried out using constructed wetland. The studied wetland was built in the form of two connected reservoirs with an area of 30 m2. In the first deep reservoir, sedimentation of suspended matter occurred, while in the second shallow reservoir, six species of aquatic plants were planted in order to assimilate nitrogen and phosphorus compounds. In the years 2014–2018, the water samples from the inflow and outflow of the constructed wetland were collected. The pH and electrical conductivity values, as well as nitrate nitrogen, ammonium nitrogen, phosphates phosphorus and chlorides concentrations were determined with electrochemical and photometric methods. The obtained results were statistically analyzed using the Statistica v. 7 software. In the majority of the runoff samples from the farmyard, abnormal concentration of ammonium nitrogen (90% of samples) and phosphate phosphorus (100% of samples) occurred in relation to the requirements for surface waters. The values of ammonium nitrogen concentration exceeded the acceptable norms for domestic sewage discharged into waters in 31% of samples and in the case of phosphate phosphorus – in 67% of samples. The concentration of chlorides exceeded the limit values for surface water in 36% of samples. The average concentration of nitrate nitrogen did not exceed these standards. There was a high correlation between the concentration of ammonium nitrogen and the concentration of phosphate phosphorus and chlorides. The efficiency of runoff treatment from the dairy cattle farm yard was very high in the initial period of research, reaching 85.4% for ammonium nitrogen and 68.3% for phosphate phosphorus, but showed a downward trend over time for the entire period.
Źródło:
Journal of Ecological Engineering; 2019, 20, 10; 225-232
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bakteriologiczne zanieczyszczenie powietrza na terenie i w otoczeniu oczyszczalni ścieków z systemem filtrów gruntowo-roślinnych
Bacteriological pollution of atmospheric air in the constructed wetland (with reed bed system) area and in the surroundings
Autorzy:
Korzeniewska, E.
Filipkowska, Z.
Gotkowska-Płachta, A.
Janczukowicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/338337.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bakterie
oczyszczalnie hydrofitowe
powietrze
air pollution
bacteria
constructed wetland
Opis:
Badania powietrza atmosferycznego przeprowadzono na terenie i w otoczeniu oczyszczalni hydrofitowej w Łęgutach, z filtrami gruntowo-roślinnymi o pionowym i poziomym podpowierzchniowym przepływie ścieków bytowo-gospodarczych, o przepustowości 60 m³ d-¹. Badano liczebność bakterii heterotroficznych psychrofilnych, psychrotrofowych i mezofilnych oraz wybranych grup fizjologicznych drobnoustrojów: z rodziny Enterobacteriaceae, rodzaju Staphylococcus i Enterococcus, gatunku Pseudomonas fluorescens, bakterii hemolizujących oraz promieniowców. Powietrze do badań pobierano w sezonach letnim, jesiennym, zimowym i wiosennym, równolegle metodą sedymentacyjną i zderzeniową na 7 stanowiskach usytuowanych na terenie oczyszczalni (przy: dopływie ścieków, osadniku Imhoffa, I i II filtrze gruntowo-roślinnym - FGR - z przepływem pionowym, osadniku pionowym, FGR z przepływem poziomym, poletku trzcinowym) oraz na 4 stanowiskach usytuowanych w jej otoczeniu. Tło wyznaczano w zależności od kierunku wiatru po stronie nawietrznej w stosunku do położenia oczyszczalni. Ponadto prowadzono pomiary temperatury i wilgotności powietrza oraz prędkości wiatru na poszczególnych stanowiskach badawczych. Stwierdzono statystycznie istotne różnice liczebności poszczególnych grup badanych drobnoustrojów w powietrzu pobieranym różnymi metodami oraz w różnych porach roku. Największą średnią ich liczebność stwierdzano zazwyczaj w próbkach powietrza pobieranego metodą sedymentacyjną, a jeśli rozpatruje się zmienność w ciągu roku - latem, najmniejszą zaś zimą. Nie stwierdzono istotnych statystycznie różnic w liczebności badanych grup drobnoustrojów w powietrzu pobieranym na poszczególnych stanowiskach badawczych. Jednakże większą ich liczebność stwierdzano w powietrzu pobieranym na stanowiskach usytuowanych na terenie oczyszczalni ścieków, szczególnie przy dopływie ścieków, osadniku Imhoffa oraz przy pionowych filtrach gruntowo-roślinnych. Uwzględniając kryteria oceny stopnia zanieczyszczenia powietrza atmosferycznego podane w Polskich Normach, poza nielicznymi wyjątkami, powietrze pobierane zarówno na terenie, jak i w otoczeniu oczyszczalni można zaklasyfikować jako mało zanieczyszczone. Nie stwierdzono podwyższonej emisji badanych grup drobnoustrojów, w tym również pochodzenia kałowego, poza obszar terenu oczyszczalni.
The study of atmospheric air was carried out within and in the surrounding of a constructed wetland in Łęguty, treating 60 m³ d-¹ of domestic wastewater, which operates in vertical and horizontal reed bed system with subsurface flow. Counts of heterotrophic psychrophilic, psychrotrophic and mesophilic bacteria as well as some physiological groups of microorganisms which belong to Enterobacteriaceae family, Staphylococcus and Enterococcus genera, Pseudomonas fluorescens species, hemolysing bacteria and actinomycetes were analysed. Air samples were collected in summer, autumn, winter and spring seasons simultaneously by the sedimentation and impact methods at 7 sites located in the area of the wastewater treatment plant (sewage inflow, Imhoff tank, I and II vertical flow reed bed, vertical sedimentation tank, horizontal flow reed bed and sludge drying reed bed) and at 4 sites situated in its surroundings. The background was selected depending on wind direction, always on the windward side of the wastewater treatment plant. In addition, temperature, air humidity, wind speed and direction were observed at each sampling site. Statistical analyses of the results showed significant differences in counts of the analysed groups of microorganisms in the air sampled with different methods and in different seasons. The highest mean numbers of microorganisms were typically found in air samples collected by the sedimentation method, especially in summer (with the exception of actinomycetes, which were most numerous in spring), whereas the lowest counts were found in winter. No statistically significant differences were found between counts of the analysed groups of microorganisms in the air sampled at different sites. However, higher counts were usually found in the air sampled at the sites on the premises of the wastewater treatment plant, especially near sewage inflow, Imhoff tank and vertical flow reed bed. According to the Polish Standards for atmospheric air pollution assessment, the air sampled at the plant and in its surroundings, with very few exceptions, was classified as only slightly polluted. In conclusion, no increased emission of the analysed groups of microorganisms, including faecal bacteria, was observed outside the wastewater treatment plant.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2008, 8, 1; 161-173
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving Wastewater Reclamation Using Constructed Wetlands by Artificial Plastic Biofilm Carriers
Autorzy:
Zaboon, Baneen Hussein
Al-Abbawy, Dunya A. H.
Yaseen, Dina A.
Powiązania:
https://bibliotekanauki.pl/articles/2202266.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment
free-water surface
Lemna minor
constructed wetland
Opis:
Increasing the demand for potable water, followed by the high quantity of discharged effluents linked with the water scarcity problems has necessitated giving more attention to improving wastewater treatment processes and operations. The constructed wetland has proven to be an excellent green sustainable technique for purification. This study aimed to examine the performance of four experimental free water surface constructed wetlands (FWSCWs) for the depuration of sewage effluents as a secondary treatment stage during winter season conditions. The objectives were to assess the raw and treated wastewater concentrations, evaluate the removal efficiency of chemical oxygen demand (COD), biological oxygen demand (BOD), nutrients, and total suspended solids (TSS) of each treatment line, and compare the impact of plastic rings (biofilm carriers) and Lemna minor L. with the presence of gravel bed on the treatment efficiency and bacterial growth, as well as assess the plant’s adaption and growth. The results showed that all treatment systems improved the water characteristics, and adding biofilm carriers enhanced the efficiency of water purification, especially BOD reduction. The combination of the plants, biofilm carriers, and gravel in the wetland filter significantly enhanced (ρ < 0.05) the treatment efficiency in terms of TSS, COD, BOD, Ammonia (NH3), Nitrates (NO3), and Orthophosphate (PO4) compared to the control treatment system (gravel bed). Plant growth was restricted in the presence of carriers in the system. Further study for examining the system performance under summer conditions, which may improve the nutrient reduction rates by biofilm carriers, is underway.
Źródło:
Journal of Ecological Engineering; 2022, 23, 11; 241--253
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent Progress of Phytoremediation-Based Technologies for Industrial Wastewater Treatment
Autorzy:
Yuliasni, Rustiana
Kurniawan, Setyo Budi
Marlena, Bekti
Hidayat, Mohamad Rusdi
Kadier, Abudukeremu
Ma, Peng Cheng
Imron, Muhammad Fauzul
Powiązania:
https://bibliotekanauki.pl/articles/2202323.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
aquatic plant
constructed wetland
environmental pollution
industrial wastewater
phytoremediation
Opis:
Phytoremediation is considered of a cost effective and environmentally friendly technology and has been used successfully for the remediation of soils and water contaminated with various pollutants. Specifically for full scale application to treat industrial wastewater, phytoremediation is used as sole technology for different types of wetlands. However, phytoremediation of polluted water in wetland type reactor has been mostly studied as black box. The method to measure the performance is only based on pollutant removal efficiency and there is very limited information available about of the pollutant removal mechanisms and process dynamics in these systems. Thus, the aim of this chapter was to briefly review basic processes of phytoremediation, its mechanisms and parameters, and its interaction between rhizo-remediation and microbe-plant. In addition, this chapter also elaborated phytoremediation challenges and strategies for full-scale application, its techniques to remove both organic and inorganic contaminants by aquatic plants in water, and some examples of applications in industries.
Źródło:
Journal of Ecological Engineering; 2023, 24, 2; 208--220
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of Acetaminophen and Methylparaben Removal within Subsurface Batch Constructed Wetland Systems
Autorzy:
Mutar, Zahraa Hasan
Mohammed, Ahmed A.
Al-Baldawi, Israa Abdulwahab
Powiązania:
https://bibliotekanauki.pl/articles/2025734.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
phytoremediation
ornamental plant
constructed wetland
PPCPs
central composite design
Opis:
The response surface methodology accompanied by Central Composite Design (CCD) was employed in this study to optimize the Alternanthera spp-based phytoremediation process for the individual removal of acetaminophen and methylparaben. Two operational variables, including concentration (A) (20, 60,100 mg/L) and sampling time (B) (7, 14, 21, and 35 days) were involved in the study for removal efficiency (Y) as response. CCD had required a total of 18 experiments for each compound. Analysis of variance (ANOVA) was conducted to verify the adequacy of the proposed mathematical models and revealed good agreement with the experimental data. The observed R2 values (0.9732 and 0.9870), adjusted R2 (0.9620 and 0.9816) and predicted R2 (0.9383 and 0.9721) for AC and MP, respectively, indicated that the developed models were significant at the 95% probability level. Concentration factor was found to be insignificant in the mathematical models; in contrast, sampling time was found to be of a crucial role. The removal of AC and MP were 89.23% and 64.48% under optimum conditions of A = 100 mg/L and B = 35 days respectively. The validation test confirmed the predicted results obtained by Central Composite Design, as the removals achieved under optimum conditions were 91.04% and 59.17% for AC and MP, respectively, which were in good agreement with the results proposed by the theoretical design.
Źródło:
Journal of Ecological Engineering; 2022, 23, 1; 228-239
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Different Plant Monocultures on Nitrogen Removal Performance in Wetland Microcosms
Autorzy:
Wang, Rujun
Quan, Ying
Zheng, ShaoKui
Zhang, Xueyu
Powiązania:
https://bibliotekanauki.pl/articles/2173379.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ammonia
constructed wetland
free-water surface
nitrate
optimization mechanism
Opis:
This study investigated the nitrogen removal performance in wetland microcosms individually planted with different plant monocultures, including emergent, free-floating and submerged plants during ammonia removals, or large- and small-leaf free-floating plants during nitrate removal. For ammonia-dominated wastewater, both emergent (common reed) and free-floating (water hyacinth) plants in wetland microcosms achieved higher total nitrogen removals than a submerged plant (eelgrass) that significantly improved the microbial nitrifying performance. For nitrate-dominated wastewater, efficient nitrate removals in wetland microcosms planted with free-floating plant were achieved by both a full cover of water surface and the concentration of organic oxygen-consuming substances, which resulted in low dissolved oxygen levels and boosted microbial denitrification in wetland microcosms. FWS-CW developers and managers should thus pay close attention to the selection of wetland plant types and optimize their design to achieve optimum nitrogen removal performance.
Źródło:
Journal of Ecological Engineering; 2022, 23, 9; 241--249
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja roślinnej oczyszczalni ścieków do usuwania barwników z roztworów wodnych
The conception of constructed wetland for dyes removal in water solutions
Autorzy:
Olejnik, D.
Wojciechowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1217146.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
oczyszczalnia
barwniki
CWS
ścieki włókiennicze
constructed wetland
dyes
textile wastewater
Opis:
Zaprojektowanie poprawnie działających oczyszczalni hydrofitowych, to zadanie wymagające zrozumienia roli poszczególnych komponentów tworzących tego rodzaju oczyszczalnie w przemianach fizykochemicznych i biochemicznych. Celem pracy jest ocena możliwości zastosowania CWS do oczyszczania ścieków barwnikarskich. Praca ta jest także przeglądem danych literaturowych opisujących oczyszczanie ścieków barwiarskich/barwników w oczyszczalniach hydrofitowych z wykorzystaniem różnych gatunków roślin.
Constructed wetlands (CWS) are ecological systems that combine biological, chemical and physical processes in an engineered and managed system. Successful designing and operation of CWS required a basic knowledge and understanding of the components and the interrelationships that compose the system. The aim of this work is to evaluate the possibility of application of CWS for treatment of textile wastewater. This paper is also a review of so far obtained literature data concerning dyes and dyeing wastewater treatment in CWS with the help of various plant species.
Źródło:
Chemik; 2012, 66, 6; 611-614
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fate and Transfer of Heavy Metals in Constructed Wetland Mesocosms Subjected Different Hydraulic Regime
Autorzy:
Mohammed, Alya A.
Al Chalabi, Ahmed S.
Sahei, Angham O.
Powiązania:
https://bibliotekanauki.pl/articles/2202285.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
ferric dewatered sludge
heavy metals
hydraulic regime
plant
Opis:
A constructed wetland may consume different levels of pollution in different types of wastewater. The focus of this study was the removal of heavy metals (Pb, Cr, and Cd) by plants and their fate in constructed wetland mesocosms. With hydraulic regime manipulation, heavy metals were retained in the ferric dewatered sludge either by adsorption to the carboxylate groups and iron oxy-hydroxide under anaerobic conditions or by co-precipitation with iron oxy-hydroxide under aerobic conditions. Under anaerobic conditions, most heavy metals accumulate in the bottom layer and decrease when moving to the top one. In turn, under aerobic conditions, most of the heavy metals accumulate in the bottom and top layers. Plants play a minor role in heavy metal removal. About 16% of total heavy metals added to the ferric dewatered treatment sludge were taken up by plants. Roots accumulated roughly 64% of the total lead take up by plants, 66% of the chromium, and 63% of the cadmium, respectively, and passed 36%, 34%, and 37% of the aboveground tissues for harvesting. As a conclusion of this study, when constructed wetland is used, the role of hydraulic regime, substance used, and vegetation should not be ignored in the process of wastewater purification in constructed wetland.
Źródło:
Journal of Ecological Engineering; 2022, 23, 12; 44--49
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plant Diversity in a Constructed Wetland for Pollutant Parameter Processing on Leachate: A Review
Autorzy:
Arliyani, Isni
Tangahu, Bieby Voijant
Mangkoedihardjo, Sarwoko
Powiązania:
https://bibliotekanauki.pl/articles/1839587.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
leachate
landfill age
installation site
plant diversity
phytotreatment
Opis:
The leachate from landfill constitutes high pollutant. The high pollutant content impacts the public and ecosystem health surrounding the landfill site. Therefore, it is essential to process the leachate first before its disposal to water body. Landfill leachate processing can be carried out using three processes, i.e., physical-chemical, biological, and a combination of those. A constructed wetland is currently considered as an environmentally friendly technology to tackle water pollution and leachate. Another advantage of a constructed wetland is the low operational cost and natural maintenance, so it can be a solution related to the cost, technical, and operating system problems of conventional processing. This article aimed to discover the characteristic differences of landfill leachate, constructed wetland installation position, and types of plants used in the constructed wetland. This article was written using the literature reviews from experimental studies on water processing with the same parameter for leachate and leachate processing. The literature review result shows that landfill leachate processing depends on different leachate characteristics. The toxic quality of landfill leachate was found through a toxicity test. Leachate treated by the physical-chemical process contains toxic and non-biodegradable organic substances. Hence, the physical-chemical methods should be applied at the beginning of the process and coupled with the biological method at the end of the process to improve the treatment quality. A constructed wetland with diverse plants was found to be more effective in biomass distribution, less prone to seasonal variations, and had a more diverse microbe population than the constructed wetland with a single plant.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 240-255
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Efficiency of Pollution Removal From Domestic Wastewater in Constructed Wetland Systems With Vertical Flow With Common Reed and Glyceria Maxima
Autorzy:
Dębska, A.
Jóźwiakowski, K.
Gizińska-Górna, M.
Pytka, A.
Marzec, M.
Sosnowska, B.
Pieńko, A.
Powiązania:
https://bibliotekanauki.pl/articles/124123.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
vertical flow
domestic wastewater
common reed
Glyceria maxima
Opis:
The paper presents the results of research on the effects of removing pollution from domestic wastewater in two beds of constructed wetland systems with vertical flow. Bed I was planted with common reed (Phragmites australis Cav. Trin. Ex Steud.), whereas bed II with Glyceria maxima (Glyceria aquatica L.). The surface of each of the beds amounted to 30 m2, and the hydraulic load of each of them amounted to 0.033 m3·m-2·d-1. The study showed very good results in the removal of most of the analyzed indicators of contamination, which were similar in both analyzed beds. They were, respectively: 91 and 93% – for total suspended solids, 96 and 98% – for BOD5, 96 and 94% – for CODCr, 88 and 86% – for ammonia nitrogen and 87 and 88% – for total phosphorus. Much smaller effects were reported with regard to total nitrogen removal – 55% in bed I with common reed and 54% in bed II with Glyceria maxima. The tested beds also eliminated the number of coliform bacteria and faecal coliform bacteria quite effectively. Average effects of the removal of coliform bacteria in bed I and II were 99.74%, in the case of faecal coliform 98.06% and 97.94% respectively. Values of basic indicators of contamination (total suspended solids, BOD5 and CODCr) in the wastewater discharged from the analyzed beds met the requirements of the Regulation of the Minister of the Environment of 2014. The test results obtained in the first year of operation of the analyzed beds show that neither of the applied plants significantly improves the results of contaminant removal.
Źródło:
Journal of Ecological Engineering; 2015, 16, 5; 110-118
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computational Fluid Dynamics Modeling of Residence Time Distribution in a Field-Scale Horizontal Subsurface Flow Constructed Wetland with Palm Kernel Shell as Substrate
Autorzy:
Okoye, Nelson Mbanefo
Madubuike, Chimaobi Nnaemeka
Nwuba, Ifeanyi Uba
Orakwe, Louis Chukwuemeka
Ugwuishiwu, O. Boniface
Powiązania:
https://bibliotekanauki.pl/articles/1163287.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
COMSOL
Computational Fluid Dynamics
Constructed Wetland
Simulation Modelling
Wastewater Treatment
Opis:
The hydraulic performance of constructed wetlands is often compromised by hydraulic problems. Therefore, the development of an appropriate simulation model to reliably predict how various modifications of bed design and configurations might affect performance will facilitate the design of efficient systems. The aim of this research work is to determine distribution of residence time in a field-scale horizontal subsurface flow constructed wetland with Palm Kernel Shell as substrate. The governing equations of flow in porous media and transport of diluted species were solved using COMSOL Multiphysics 5.3a. The result was validated using experimental data and the model result showed good agreement with a correlation coefficient of 0.99. Alternative wetland designs were assessed for the same flow conditions. The results revealed that a two cell wetland improved short-circuiting flow paths.
Źródło:
World Scientific News; 2018, 109; 60-70
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Trickling Filter and Vertical Flow Constructed Wetland Bed to Treat Sewage from Craft Brewery
Autorzy:
Dąbrowski, Wojciech
Karolinczak, Beata
Powiązania:
https://bibliotekanauki.pl/articles/124568.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
craft brewery
sewage treatment
trickling filter
vertical flow constructed wetland
Certyd
Opis:
In Poland, as well as worldwide, an increase in craft beer production can be observed. In the last several years, more than 150 of such breweries have appeared and according to Polish Brewery Association, their number might ultimately reach 500. Many of them emerge in the areas with no access to a central sewerage system so they have to solve the problem of waste management on their own. The article presents the results of research on the possibility of using a hybrid system for biological treatment of sewage from craft breweries. The sewage came from a craft brewery Waszczukowe located in the Podlaskie province. A laboratory scale model consisted of a trickling filter (TF) (research model Gunt CE701e) and vertical flow constructed wetland (SS-VF). Innovative filling (Certyd produced by LSA company) of TF and SS VF was applied. The conducted study included determining the changes in the sewage parameters during hybrid treatment, as well as TF and SS VF efficiency separately. The aim of the research was to show the possibility of treating sewage to a point when it was possible to discharge it to a receiver, in compliance with the Polish legal regulations. The research results might be used in designing a treatment system or sewage pretreatment in craft breweries. The average efficiency of TF operating with 100% recirculation was 76% for BOD5, 80% for COD, 26% for TN and 34% for TP, while the total treatment efficiency of a hybrid system (TF and SS-VF) was 98%, 98%, 72% and 77%, respectively. The load of TF during operation with recirculation was on average 0.38 kg BOD5 m-2d-1, 0.57 kg COD m-2 d-1. The load of SS-VF was on average 0.09 kg BOD5 m-2 d-1 and 0.12 kg COD m-2d-1. The obtained results of hybrid treatment permitted to discharge the sewage to the receiver.
Źródło:
Journal of Ecological Engineering; 2019, 20, 9; 211-217
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of COD Fractions in Raw Wastewater Flowing into Small and Large Wastewater Treatment Plants
Autorzy:
Ignatowicz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/124764.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD fractions
treatment plants
rotary biological contactor
constructed wetland
activated sludge
Opis:
The aim of the study was to determine and compare the amount and biodegradability of organic compounds determined by the COD measure contained in raw sewage inflowing to small sewage treatment plants and municipal sewage wastewater treatment plants with high personal equivalent (P.E.). Raw sewage samples were collected in three chosen facilities. The research presented in the article were conducted with two small plants: constructed wetland plant with an average capacity of 4 m3/d and the treatment plant with rotary biological contactor (RBC) with an average capacity of 5 m3/d. Also big municipal wastewater treatment plant (WWTP) with activated sludge in Bialystok with a capacity of about 63 000 m3/d was checked. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was founded in raw sewage in small wastewater treatment plants (CW and RBC).
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 197-201
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heavy Metals Removal from Simulated Wastewater using Horizontal Subsurface Constructed Wetland
Autorzy:
M-Ridha, Mohanad J.
Zeki, Suhair L.
Mohammed, Sabah J.
Abed, Khalid M.
Hasan, Hassimi Abu
Powiązania:
https://bibliotekanauki.pl/articles/1955516.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
heavy metal removal
phytoremediation
horizontal subsurface constructed wetland
Nerium oleander
waste treatment
Opis:
This study aimed to assess the efficiency of Nerium oleander in removing three different metals (Cd, Cu, and Ni) from simulated wastewater using horizontal subsurface flow constructed wetland (HSSF-CW) system. The HSSF-CW pilot scale was operated at two hydraulic retention times (HRTs) of 4 and 7 days, filled with a substrate layer of sand and gravel. The results indicated that the HSSF-CW had high removal efficiency of Cd and Cu. A higher HRT (7 days) resulted in greater removal efficiency reaching up to (99.3% Cd, 99.5% Cu, 86.3% Ni) compared to 4 days. The substrate played a significant role in removal of metals due to adsorption and precipitation. The N. oleander plant also showed a good tolerance to the uptake of Cd, Cu, and Ni ions from water. The highest removal of the heavy metals indicated that the HSSF-CW would be a promising technology for heavy metal contaminated wastewater as well as in electroplating and manufacturing industries.
Źródło:
Journal of Ecological Engineering; 2021, 22, 8; 243-250
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment Ability and Community Responses of Candung as an Appropriate Technology to Maintain Irrigation Water Quality
Autorzy:
Sumantra, I. Ketut
Widnyana, I. Ketut
Wijaya, I. Made Wahyu
Bouchama, Khaled
Powiązania:
https://bibliotekanauki.pl/articles/24202905.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
candung
constructed wetland
irrigation water
Nelumbo nucifera
Nymphaea tetragona
Pistia stratiotes
agrotourism
Opis:
With the burgeoning population, the community activities, such as laundering, washing, or even bathing, have expanded along the irrigation canal. Consequently, some chemicals from those activities are released and pollute the water body. Besides, the discharge of wastewater into the irrigation system is also an issue of public health concern, because it creates an environment conducive to the reproduction of any pathogenic agent. Using candung as constructed wetlands (CW)-like to treat the irrigation water in rice paddies would be an interesting tool for removing pollutants from the irrigation water. Candung, as a locally used CW in Bali Island, has been applied in the rice field long time ago. The present study aimed to examine candung as a local attached CW or treating irrigation water and analyse the community awareness regarding the candung application. The result showed a positive effect of candung in maintaining the water quality parameters, such as TSS, BOD, COD, and nutrients with certain aquatic plants (Nelumbo nucifera, Nymphaea tetragona, and Pistia stratiotes). The knowledge, behaviour, and action of the local subak community were still limited, whereas they had positive perceptions and responses about candungthe potential of candung as an agrotourism attraction in the village as well.
Źródło:
Journal of Ecological Engineering; 2023, 24, 6; 348--365
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grzyby pleśniowe oraz drożdże i grzyby drożdżoidalne w powietrzu atmosferycznym na terenie oczyszczalni ścieków z systemem stawów napowietrzanych i stabilizacyjnych
Moulds, yeasts and yeast-like fungi in the atmospheric air at constructed wetland systems (whit aerated and stabilization ponds) and in the surrounding area
Autorzy:
Filipkowska, Z.
Gotkowska-Płachta, A.
Korzeniewska, E.
Powiązania:
https://bibliotekanauki.pl/articles/338378.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
drożdże
grzyby
oczyszczalnie hydrofitowe
pleśnie
powietrze
air
constructed wetland
fungi
moulds
yeasts
Opis:
Badania powietrza atmosferycznego pod kątem obecności pleśni (identyfikowanych do rodzaju) oraz drożdży i grzybów drożdżoidalnych (identyfikowanych za pomocą testów API 20 C AUX) przeprowadzono na terenie i w otoczeniu hydrofitowej (z systemem stawów napowietrzanych i stabilizacyjnych) oczyszczalni ścieków bytowo-gospodarczych o przepustowości ok. 170 m³ ·d-¹. Próbki powietrza pobierano w sezonach letnim, jesiennym, zimowym i wiosennym (równolegle metodą sedymentacyjną i zderzeniową) na 6 stanowiskach na terenie oczyszczalni oraz na 4 stanowiskach w jej otoczeniu. Stanowisko kontrolne (tło badań) wyznaczano zawsze po stronie nawietrznej oczyszczalni. Grzyby, stwierdzane w powietrzu jesienią, zimą i wiosną na terenie oczyszczalni ścieków, zgodnie z Polską Normą - PN-89 Z-04111/03 (poza próbkami powietrza pobranymi jesienią przy ogrodzeniu obiektu), występowały w ilościach niezagrażających środowisku naturalnemu człowieka. W okresie letnim natomiast liczebność badanych grzybów w próbkach powietrza przekraczała często 5,0· 10³ jtk·m-³ (mogły więc one negatywnie oddziaływać na środowisko). Dominującymi drobnoustrojami były pleśnie z rodzajów: Alternaria, Aspergillus, Cladosporium, Diplosporium, Mucor, Scopulariopsis. Na terenie oczyszczalni dodatkowo często stwierdzano pleśnie z rodzajów: Absidia, Actinomucor, Botrytis, Chrysosporium, Trichoderma; w otoczeniu obiektu natomiast: Botrytis, Penicillium, Trichoderma i Trichothecium. Drożdże i grzyby drożdżoidalne zazwyczaj stanowiły niewielki procent ogólnej liczby grzybów. W próbkach powietrza pobranych na terenie oczyszczalni drożdże należały do gatunków: Candida sp., Cryptococcus laurentii, Hansenula sp., Pichia sp. oraz Rhodotorula sp., Saccharomyces cerevisiae: w otoczeniu oczyszczalni zaś do: Candida sp., Cryptococcus laurentii, Cryptococcus neoformans, Cryptococcus sp., oraz Trichosporon mucoides.
This paper characterizes the influence of constructed wetland system (with aerated and stabilizations ponds) on the mycological (moulds and yeast) pollution of atmospheric air at wastewater treatment plant (WTP) and in the surroundings. Air samples were collected in variable weather conditions, using sedimentation and impact methods, in 4 measurement series, i.e. in the summer and autumn 2006 and in the winter and spring 2007, in 11 sampling sites. The air-sampling locations were selected with respect to the highest expected emissions of the bioaerosol and wind velocity and direction on sampling days. Fungi were isolated on RBC (Rose Bengal Chloramphenicol Agar) medium. Moulds were the dominant fungal group in the WTP and surrounding area. According to the Polish Norm PN-89 Z-04 111/03, the number of fungi in air at WTP in autumn, winter and spring (except for the samples collected in autumn in a site near fence) were not harmful to human environment. However, the number of fungi exceeding 5.0 · 10³ jtk·m-³ in summer could have negative influence on the environment. Such large numbers of fungi occurred in air samples collected in summer in WTP area near several facilities (vertical sedimentation tank, reed field, tank for sludge storage); near the fence (also in autumn) and at a distance from 0 to 25 m from the fence. The prevailing microorganisms were moulds of the genus Alternaria, Aspergillus, Cladosporium, Diplosporium, Mucor, Scopulariopsis. Other moulds found in the air on the WTP premises belonged to the genus: Absidia, Actinomucor, Botrytis, Chrysosporium, Trichoderma; in the surroundings of the treatment plant there were also Penicillium, and Trichothecium. Yeast and yeast-like fungi constituted a small percentage of the total number of fungi. In the air samples collected at the constructed wetland area, the following taxa were identified (with the API 20 C AUX test): Candida sp., Cryptococcus laurentii, Cryptococcus sp., Hansenula sp., Pichia sp., Rhodotorula sp. and Saccharomyces cerevisiae; in the air of the surrounding area Candida sp., Cryptococcus laurentii, Cryptococcus neoformans, Cryptococcus sp. and Trichosporon mucoides were determined.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2008, 8, 1; 69-82
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie odcieków z beztlenowej stabilizacji osadów z oczyszczalni ścieków mleczarskich przy zastosowaniem metody hydrofitowej
Treatment of Reject Water from Anaerobic Sewage Sludge Stabilization in Constructed Wetland
Autorzy:
Dąbrowski, W.
Wiater, J.
Boruszko, D.
Powiązania:
https://bibliotekanauki.pl/articles/1818578.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
odcieki
stabilizacja osadów ściekowych
złoża hydrofitowe
reject water
sewage sludge stabilization
constructed wetland
Opis:
The paper presents author's experience related to reject water treatment with constructed wetland (CW). CW technology is well known worldwide to treat municipal wastewater, rainwater and also industrial wastewater. The problem with reject water is mainly concerning high concentration of ammonia nitrogen. It is observed mainly in municipal WWTPs utilizing anaerobic sewage sludge stabilization. Dairy WWTP belonging to Mlekovita was modernized in 2013 with implementation of flotation process in wastewater line and anaerobic stabilization of excess and flotation sludge. Probably this is the biggest dairy WWTP in Poland. It is operating (July 2014) with 6886 m3/d and personal equivalent about 278 000 (project was done for PE 35 0000 and maximum flow 75000 m3/d). Reject water as a byproduct like sewage sludge is returned to the beginning of wastewater line. During own research with reject water it was found that concentration of ammonia nitrogen was varied from 291 N-NH4+/dm3to 423 mg N-NH4+/dm3. while value of BOD5 from 132 to 185 mg O2/dm3. Laboratory scale investigation was carried out with vertical flow CW model with total depth 0,65 m. filled with gravel and sand. Two hydraulic loads were applied during investigations – 0,1 and 0,2 m/d. The temperature during two series was changing from 22,0 do 26,0°C. High efficiency of BOD5 removal (up to 91%) from reject water produced in dairy WWTP was observed. The efficiency of ammonia nitrogen removal was varied from 78,3% to 90,0%. The efficiency of total phosphorus removal was low in both series. Vertical flow constructed wetland can be used as a low cost method to decrease load of dairy WWTP utilizing anaerobic sewage sludge utilization. To increase efficiency of reject water treatment lower hydraulic load (from 0,05 m/d) should be applied. Future researches will be carried out with real scale installation in Wysokie Mazowieckie equipped with special aeration system to supply vertical flow CW with oxygen.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 869-879
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of SS-VF Bed for the Treatment of High Concentrated Reject Water from Autothermal Termophilic Aerobic Sewage Sludge Digestion
Autorzy:
Dąbrowski, W.
Malinowski, P.
Karolinczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/123643.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal thermophilic aerobic digestion
ATAD
reject water
vertical flow constructed wetland
SS VF
Opis:
The autothermal termophilic aerobic digestion (ATAD) technology is used in the municipal and industrial wastewater treatment plants (WWTPs) with personal equivalent up to 30.000. The process provides a high level of sewage sludge stabilization and its hygienization. The main operation problems are caused by the high concentration of nitrogen and phosphorus in the reject water from sewage sludge treatment and air purification (odor removal). Reject water usually is returned to the main sewage treatment, which has a negative impact, especially on the sewage treatment systems based on the sequence batch reactors (SBR). Applying high-performance and expensive separate reject water treatment methods such as SHARON, Anammox or CANON in small facilities is not justified economically. The article presents the research results concerning the effectiveness of applying subsurface vertical flow constructed wetlands (SS VF) for reject water treatment from the ATAD process. An innovative type of bed filling was used, which was produced from waste (ash from a heat and power plant). The efficiency of reject water treatment during the research period was on average at 45.6% for ammonia nitrogen, 32.3% for total phosphorus and 85.1% for BOD5. Applying SS VF beds for separate reject water treatment might ensure a stable and effective functioning of municipal WWTPs by decreasing the load of biological part of a WWTP.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 103-110
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nitrogen and phosphorus content in constructed wetlands
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/1838101.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
waste water treatment
constructed wetland
nitrogen
phosphorus
oczyszczalnie ścieków
oczyszczalnia hydrofitowa
azot
fosfor
Opis:
High effectiveness of organic pollutants and nutrients removal is achieved in biological wastewater treatments plants – in case of proper exploitation of these objects. Nitrogen and phosphorus transformation or removal depends on many physic – chemical and biochemical conditions, deposit and environmental factors. A rule for treating wastewater consists in decomposition of organic compounds included in wastewater in water-soil environment. Removing contaminations is performed as a result of sorption of contaminations, bio-chemical oxidation-reduction reactions and biological activity of soil microorganisms and hydrophyte flora. The research has been carried out in the constructed wetland in Małyszyn (1300 EP). The treatment plant operates in horizontal system, with under-surface flow of wastewater.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 2; 247-257
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of subsurface vertical flow constructed wetlands receiving municipal wastewater
Autorzy:
Kowalik, P.
Mierzejewski, M.
Randerson, P. F.
Williams, H. G.
Powiązania:
https://bibliotekanauki.pl/articles/241164.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
constructed wetland
municipal wastewater
nitrogen
Phragmites australis
phosphorus
sewage
suspended solids
wastewater treatment
Opis:
The efficiency of pollution removal from municipal sewage in two vertical flow constructed wetlands consisting of gravel filters with a surface area of 4 × 5 m, depth 60 cm, planted with reed (Phragmites) was assessed over a period of about two years. The flow of wastewater was 50 mm per day. Wastewater underwent only primary treatment before application to reed bed B, but reed bed A was supplied with wastewater after mechanical and biological treatment. Measurements were taken of sewage supply and discharge, precipitation and wastewater temperatures. The main indicator of efficiency was the elimination of suspended solids, BOD5, nitrogen and phosphorus from the wastewater during treatment. The elimination of the pollution load was 2-25g O2 per square meter per day for the BOD5 and 0-3.5 g per square meter per day for so-called "total nitrogen". Rates of pollution removal were between 2 and 4 times as high in bed B (after primary treatment) as in bed A (after biological treatment), but the loading rate of bed B was also substantially higher. The rate of BOD5 removal and the coefficient k for BOD5 were greatly dependent on temperature for reed bed B (primary treatment); less so for bed A (biological treatment). The difference between summer and winter temperatures indicates that the surface area of constructed wetland B with wastewater after mechanical treatment should be about 3 times greater during winter, to obtain the summer rate of BOD5 pollution removal in the climatic conditions of Northern Poland (54oN).
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2004, 51, 4; 349-370
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of Design Model Constants for a Constructed Wetland with Palm Kernel Shell as Substrate for Slaughterhouse Wastewater Treatment
Autorzy:
Okoye, Nelson Mbanefo
Madubuike, Chimaobi Nnaemeka
Nwuba, Ifeanyi Uba
Powiązania:
https://bibliotekanauki.pl/articles/1161604.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Constructed Wetland
Eichhornia crassipes
Palm Kernel Shell
Physicochemical Parameters
Slaughterhouse Wastewater
Thalia geniculate
k-C* Model
Opis:
Design of horizontal subsurface flow constructed wetlands using the state of the art k-C* first order model requires the use of correct model constants to ensure that the design systems meets the required treatment standards. The aim of the study was to estimate the model constants for the design of a field scale horizontal subsurface flow constructed wetland to treat slaughterhouse wastewater using palm kernel shell as substrate. A 40 days column incubation was conducted and the model was fitted to experimental data. Rate constant (k20) values of 0.604/day, 0.623/day, 0.278/day, 0.323/day and 0.306/day were obtained for BOD, TSS, NH4-N, NO3-N and PO43-. Estimated model constants were compared to the universal values in the literature which revealed very significant variations in the obtained wetland surface area.
Źródło:
World Scientific News; 2018, 112; 153-164
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Duckweed does not improve the efficiency of municipal wastewater treatment in Lemna System plants
Rzęsa nie poprawia efektywności oczyszczania ścieków komunalnych w oczyszczalniach typu Lemna System
Autorzy:
Ozimek, T.
Dąbrowski, W.
Florkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/205440.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
municipal wastewater
constructed wetland
Lemna System
Lemna minor
ścieki komunalne
oczyszczalnia ścieków
Lemna system
staw napowietrzny
Opis:
his study investigated the operation of three full-scale Lemna System surface flow municipal wastewater treatment plants, built according to the Lemna Corporation design. These plants consist of two ponds, the first aerated and the second for duckweed, with a barrier grid in the latter to ensure uniform plant distribution across its area. According to designers duckweed improves the efficiency of wastewater treatment. The three treatment plants are situated in central Poland and they differ in the occurrence of duckweed, two of them, located in Raków and Bąkowiec, operate without duckweed. and the third in Falęcin Stary, Lemna minor covers ca. 90% of second pond surface. The efficiency of Lemna System wastewater treatment was found not to differ between the plants with and without duckweed. The aerated pond played the main role in reduction of pollutants in the investigated Lemna Systems.
Badania prowadzono w trzech czyszczalniach hydrofi towych z powierzchniowym przepływem ścieków typu Lemna System, zbudowanych według projektu Lemna Corporation. Składają się one ze stawu napowietrzanego i stawu rzęsowego wyposażonego w system barier mających na celu równomierne rozmieszczenie roślin. Stawy poprzedzone są osadnikiem wstępnym. Według projektantów odpowiednia praca tych oczyszczalni związana jest z występowaniem rzęsy na powierzchni stawu rzęsowego. Badano efektywność oczyszczania ścieków komunalnych w trzech oczyszczalniach Lemna System usytuowanych w centralnej Polsce ze szczególnym uwzględnieniem roli stawu rzęsowego i samej rzęsy. Oczyszczalnie różniły się między sobą występowaniem rzęsy. W dwóch z nich (w Rakowie i Bąkowcu) w trakcie całego okresu badań rzęsa nie występowała, natomiast w trzeciej (w Falęcinie Starym) w okresie wegetacyjnym pokrywała do 90%.powierzchni stawu. Efektywność oczyszczanie ścieków nie różniła się w oczyszczalni z rzęsą i bez rzęsy. Rzęsa nie wpływała istotnie na efektywność oczyszczania ścieków. We wszystkich oczyszczalniach główną rolę w redukcji zanieczyszczeń odgrywał staw napowietrzany.
Źródło:
Archives of Environmental Protection; 2015, 41, 3; 47-52
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne rozwiązanie gospodarki ściekowej i grzewczej w monasterze w Zwierkach
Ecological sewage management solution and heating in the monastery in Zwierki
Autorzy:
Ignatowicz, K.
Smyk, J
Powiązania:
https://bibliotekanauki.pl/articles/399716.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
przydomowa oczyszczalnia ścieków
oczyszczalnia hydrofitowa
proekologiczne systemy grzewcze
wastewater treatment plants
constructed wetland
environmentally friendly heating systems
Opis:
Przedstawione w pracy badania dotyczą oceny efektywności działania przydomowej oczyszczalni ścieków ze złożem hydrofitowym w Zwierkach. W ściekach pobranych z poszczególnych etapów oczyszczania wykonano analizy BZT5, ChZT, form azotu i fosforu. Na podstawie uzyskanych wyników stwierdzono dużą skuteczność usuwania BZT5, ChZT, azotu amonowego i fosforanów. W pracy zaproponowano także zastosowanie ekologicznego rozwiązania systemu grzewczego oraz redukcję kosztów poprzez modernizację systemu przygotowania ciepłej wody użytkowej w klasztorze w Zwierkach. Założenie przewiduje wspomaganie procesu przygotowania ciepłej wody użytkowej od kwietnia do września za pomocą systemu solarnego w układzie pośrednim, a tym samym częściowe zastąpienie energii pozyskiwanej ze źródeł konwencjonalnych – w tym przypadku z paliwa jakim jest ekogroszek – energią słoneczną pozyskiwaną przez system solarny.
The study focused on the effectiveness of household sewage treatment plant in Zvierki. Were tested wastewater from the septic tank, the well with a diffuser, from the well of sludge, wastewater after filtration through filter with plants and the receiver of treated sewage – the pond. Checked the ability to remove a treatment with respect to BOD5, COD, ammonia nitrogen, nitrates and phosphates. Based on the results high efficiency removal of BOD5, COD, ammonia nitrogen and phosphate. Unfortunately, there was no reduction of nitrates – there has been a significant increase in this ratio from baseline. After comparing the final values to the limit values defined in the Polish legislation, it was found that the test treatment works in accordance with the requirements except for total phosphorus. Proposed reduction of costs through modernization of the domestic hot water in a monastery in Zvierki. The assumption provides support for the process of preparing hot water from April to September, with the solar system in the intermediate system, and thus the partial replacement of energy from conventional sources – in this case, the fuel which is coal – solar energy produced by the solar system.
Źródło:
Inżynieria Ekologiczna; 2014, 40; 7-16
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Survey of plant species present on constructed wetlands in Opalenica municipality
Analiza i porownanie wybranych przydomowych oczyszczalni hydrofitowych na terenie Gminy Opalenica
Autorzy:
Zmirek, M
Gawronski, S.
Powiązania:
https://bibliotekanauki.pl/articles/81657.pdf
Data publikacji:
2009
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
plant species
constructed wetland
Wielkopolska region
Opalenica municipality
village
macrophyte species
small community
waste water treatment
rural community
environment protection
Źródło:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation; 2009, 41, 2; 143-152
0208-5771
Pojawia się w:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych makrofitów na skuteczność oczyszczania ścieków w stokowych złożach filtracyjnych gruntowo-roślinnych
Influence of selected macrophytes on sewage treatment effectiveness in the slope soil-vegetation filtration beds
Autorzy:
Jucherski, A.
Walczowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/239182.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnia hydrofitowa
stokowe złoże gruntowo-roślinne
skuteczność oczyszczania ścieków
makrofity
constructed wetland
slope soil-vegetation bed
sewage treatment efficiency
macrophytes
Opis:
Celem wieloletnich badań była ocena wpływu monokulturowych nasadzeń manny mielec (Glyceria maxima (Hartm.) Holmb.), mozgi trzcinowatej (Phalaris arundinacea L.) i trzciny pospolitej (Phragmites australis) na skuteczność oczyszczania ścieków bytowych w poletkowych segmentach złóż filtracyjnych oraz wybór rośliny najbardziej przydatnej do stosowania na stokowych złożach gruntowo-roślinnych, opracowanych w GCB w Tyliczu. Manna mielec wykazała najlepszą kondycję botaniczną, dobre wskaźniki ewapotranspiracji (7,9 dm3*m-2*d-1) oraz najlepszą średnią wieloletnią skuteczność oczyszczania ścieków, zarówno w składnikach biogennych zanieczyszczeń (92,9% - Ncałk. i 87,4% - P-PO4), jak i we wskaźnikach BZT5 (90,6%) i ChZT (87,9%). Trzcina, ze względu na nadmierną ekspansję korzeniową, stwarza niebezpieczeństwo zagęszczania i wypierania mineralnych składników złóż, natomiast mozga trzcinowata jest mało stabilna pod względem kondycji biologicznej, a jej wpływ na skuteczność oczyszczania ścieków w złożu najmniejszy.
The aim of presented long-term research was to evaluate the influence of particular monocultures: reedgrass (Glyceria maxima Hartm.), reed Canary grass (Phalaris arundinacea L.) and common reed (Phragmites australis), on the effectiveness of household sewage treatment in the plot segments of filtration beds, and to select the most useful plant to be cultivated on slope type soil-vegetation filter beds (constructed wetland) of theTylicz system. The plot overgrown with reed grass showed the best botanical condition, good evapotranspiration rate (7.9 dm3*m-2 per day) and the highest long-term average effectiveness of sewage treatment, both in nutrient components (92.9% Ntot. and 87.4% P-PO4), as well as BOD (90.6%) and COD (87.9%) rates. The common reed, because of its exaggerated root proliferation, creates a danger of thickening and replacing mineral components of the bed. On the other hand, the reed canary grass is biologically unstable and its influence on the effectiveness of sewage treatment in constructed wetland proved to be the least.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 1, 1; 115-124
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eutrofizacja wód zbiorników zaporowych oraz rola makrofitów w tym procesie
Eutrophication of water reservoirs and role of macrophytes in this process
Autorzy:
Sender, J.
Jaruga, C.
Powiązania:
https://bibliotekanauki.pl/articles/401685.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
eutrofizacja
makrofity
zbiornik zaporowy
biogeny
strefy buforowe
zlewnia
oczyszczalnie hydrofitowe
eutrophication
macrophytes
water reservoir
nutrients
buffer zone
catchment
constructed wetland
Opis:
W pracy przedstawiono zagadnienie związane z procesem eutrofizacji wód, ze szczególnym uwzględnieniem zbiorników zaporowych. Eutrofizacja to procesem globalnym, zagrażający ekosystemom wodnym na każdym kontynencie. Często doprowadza ona do ich degradacji. Szczególnie narażonymi na to zjawisko są zbiorniki sztuczne jakimi są zbiorniki zaporowe. W pracy przedstawiono mechanizmy procesu eutrofizacji. Wskazano także na znaczenie roślin wodnych w procesie oczyszczania wód, możliwości ich wielostronnego zastosowania. W ostatnim okresie w Polsce i na świecie obserwuje się tendencję do nakierowania badań na naturalne, czy półnaturalne metody oczyszczania wód, w tym także oczyszczalnie hydrofitowe. Obecność makrofitów w zbiornikach wodnych to z jednej strony gwarant dobrego stanu ekologicznego, z drugiej niezaprzeczalny walor estetyczny.
The paper presents the problem related with the process of eutrophication, with special emphasis on dam reservoirs. Eutrophication is a global process, threatening the water ecosystem on every continent. It often leads to their degradation. Particularly vulnerable to eutrophication are artificial reservoirs which are dam reservoirs. This paper describes the mechanisms of eutrophication. We also pointed to the importance of aquatic plants in the process of water purification, as well as the possibility of multilateral use. Recently, in the world and in Poland there is a tendency to pay attention to the natural or semi-natural method of water purification (including constructed wetland). On the one hand, the presence of macrophytes in water bodies is a guarantor of good ecological status, on the other hand, the undeniable aesthetic value.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 3; 227-244
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quasi-techniczne oczyszczalnie ścieków w ochronie zasobów wody na wiejskich terenach górzystych
Quasi-technical sewage treatment plants in protection of the water resources on rural mountain terrains
Autorzy:
Jucherski, A.
Walczowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/239879.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
górska oczyszczalnia gruntowo-roślinna
obszar górzysty
ochrona środowiska
teren wiejski
zasoby wody
environment protection
mountain areas
rural terrains
mountain constructed wetland
water-head resources
Opis:
Ochrona obszarów źródliskowych na przyrodniczo cennych wiejskich terenach górzystych wymaga stosowania skutecznych i komplementarnych systemów oczyszczania ścieków bytowych, w tym rozwiązań indywidualnych. Przedstawiono wyniki wieloletnich (2005-2011) badań quasi-technicznej instalacji oczyszczającej - technologicznej propozycji Górskiego Centrum Badań i Wdrożeń w Tyliczu, przykładu rozwiązania problemu ścieków bezpośrednio w zagrodzie wiejskiej. Instalacja składa się z osadnika przepływowego, urządzenia ze zraszanym złożem ze spiekanych granulatów gliniasto-ilastych (keramzyt) oraz stokowego złoża filtracyjnego gruntowo-roślinnego. Średnie wieloletnie wyniki skuteczności zmniejszania wskaźników i stężenia zanieczyszczeń w oczyszczanych ściekach, określone odpowiednio w okresach: wiosenno-letnich i jesienno-zimowych: 99,5 i 95,0% (N-NH4); 87,0 i 73,8% (Nog.); 88,7 i 83,6% (P-PO4); 98,9 i 98,8 (BZT5) 91,3 i 92,9% (ChZT) oraz 76,1 i 79,6% (zawiesina ogólna) są na poziomie rekomendacji i wymagań Komisji Helsińskiej HELCOM i Szwecji. Odniesienie uzyskanych wyników do poziomu wymagań ustanowionych w celu ochrony wód Bałtyku uznano za najbardziej właściwe.
Conservation of the water-head areas on naturally valuable, mountain rural terrains, requires the application of effective and complementary treatment systems of domestic waste-water, including the individual solutions. The results of long-term (2005-2011) study on quasitechnical water purifying installation - a technological proposal of the Mountain Centre for Research and Implementation at Tylicz - were described. The installation, designed to solve the problem of sewage treatment directly in a single mountain farmstead, consists of a through-flow settlement tank, followed by the plant of sprinkled bed filled with the sintered granules of clay materials, and finally, the slope soil-vegetation filtering beds and the water pond as a receiver. The results of long-term effectiveness in reducing the rates and concentration of pollutants in treated waste-water, determined respectively in spring-summer and autumn-winter periods, were as follows: 99.5 and 95.0% N-NH4; 87.0 and 73.8% Ntot; 88.7 and 83.6% P-PO4; 98.9 and 98.8% BOD5; 91.3 and 92.9% COD; 76.1 and 79.6% of total suspended solids. Above mentioned values meet the recommendations and requirements of the HELCOM Helsinki Commision and Sweden. Reference of obtained results to the level of these requirements was considered to be most appropriate.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 3, 3; 151-158
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Influence of a Hybrid Constructed Wetland Wastewater Treatment Plant on the Water Quality of the Receiver
Analiza wpływu hybrydowej gruntowo-roślinnej oczyszczalni ścieków na jakość wód odbiornika
Autorzy:
Gizińska-Górna, M.
Jóźwiakowski, K.
Marzec, M.
Pytka, A.
Sosnowska, B.
Różańska-Boczula, M.
Listosz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1813901.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
constructed wetland system
wastewater treatment
surface water
sewage receiver
river
water quality
oczyszczalnie gruntowo-roślinne
oczyszczalnie ścieków
wody powierzchniowe
odbiornik ścieków
rzeka
jakość wód
Opis:
This paper presents the results of research on the impact of the composition of wastewater discharged from a hybrid constructed wetland wastewater treatment plant on the quality of water in the Urzędówka River, a right tributary of the Wyżnica River. During the years 2011-2013, samples of treated wastewater and water from the river were collected (upstream and downstream of the wastewater discharge point) and subjected to physicochemical analysis and, in 2013, also to microbiological analysis. The study showed that the treated wastewater outflowing from the treatment plant did not have any negative influence on the quality of the water in the receiver. Water from the Urzędówka River met clarity standards for class I waters; only the concentrations of total phosphorus and nitrate nitrogen exceeded the limit values for water clarity class II. The studies have shown that waters from the Urzędówka River upstream of the treatment plant contained a huge concentration of E. coli bacteria, fecal coliform bacteria and fecal enterococci, which indicates the impact of other sources of microbiological pollution.
W pracy przedstawiono wyniki badań dotyczące wpływu ścieków odprowadzanych z hybrydowej oczyszczalni hydrofitowej na jakość wód z rzeki Urzędówki, prawostronnego dopływu rzeki Wyżnicy. Próby ścieków oczyszczonych oraz wód z rzeki (powyżej i poniżej miejsca zrzutu ścieków) do analiz fizyczno-chemicznych pobierano w latach 2011-2013, a do analiz mikrobiologicznych w 2013 roku. Na podstawie wyników badań stwierdzono, że ścieki oczyszczone, odpływające z gruntowo-roślinnej oczyszczalni nie miały negatywnego wpływu na jakość wód odbiornika. Wody rzeki Urzędówki odpowiadały I kasy czystości, jedynie zawartość fosforu ogólnego oraz azotu azotanowego przekraczała wartości graniczne określone dla II klasy czystości. W wodzie z rzeki przed zrzutem ścieków oczyszczonych notowano wysoką liczebność bakterii grupy coli i coli typu kałowego oraz enterokoków kałowych, co wskazuje na oddziaływanie innych źródeł zanieczyszczeń mikrobiologicznych.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 370-393
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków z małych przetwórni owocowo-warzywnych w oczyszczalniach hydrofitowych
The treatment of wastewater from small fruit and vegetable processing plants in the constructed wetlands
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339063.pdf
Data publikacji:
2003
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZTCr
substancja organiczna
ścieki z przetwórni owocowo-warzywnych
złoża hydrofitowe
BOD5
CODCr
organic substance
wastewater from fruit and vegetable processing plants
constructed wetland
Opis:
W pracy przedstawiono wyniki badań dotyczące oczyszczania ścieków z małych przetwórni owocowo-warzywnych w 4 oczyszczalniach hydrofitowych. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna – BZT5 tych ścieków wynosiło od 1 100 do 7 100 g O2·m-³, zaś ChZTCr, - od 1400 do 10 200 g O2·m-³. Średnia skuteczność usuwania substancji organicznej ze ścieków oczyszczanych na złożach hydrofitowych z podpowierzchniowym poziomym przepływem, wyrażona zmniejszeniem BZT5, wynosiła od 34 do 67%, a zmniejszeniem ChZTCr - od 31 do 71%, w zależności od obciążenia tych złóż ściekami. Lepsze, lecz jeszcze dalece niewystarczające rezultaty, uzyskano w złożu z przepływem pionowym. Średnie zmniejszenie wartości wskaźnika BZT5 sięgało tam 86,9%, a ChZTCr - 82,6%.
Efficiency of 4 constructed wetlands in contaminants removal from wastewater produced in fruit and vegetable processing plants has been investigated. The main contaminant in this wastewater, otherwise poor in N and P, was the organic substance. Its concentration as BOD5 was 1 100 to 7 100 g O2·m-³ and as CODCr - 1400 to 10 200 g O2·m³. Mean BOD5 and CODCr removal on 3 beds with the horizontal subsurface flow depended on the organic substances loading rates and varied in a wide range between 34 and 67 % for BOD5 and between 31 and 64 for CODCr. Better, but still very insufficient results were obtained on the bed with a vertical flow. Its mean removal of BOD5 reached 86.9 % and that of CODCr - 82.6 %.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2003, 3, 2; 119-128
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości oczyszczania ścieków bytowych w quasi technicznej instalacji zagrodowej typu IBMER na terenach górzystych
The quality of farm house-hold wastewater treatment in quasi-technical farmstead installation of IBMER model, in winter period on the mountainous terrain
Autorzy:
Jucherski, A.
Powiązania:
https://bibliotekanauki.pl/articles/238623.pdf
Data publikacji:
2007
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczanie ścieków
obiekt gruntowo-roślinny
klimat
teren górzysty
oczyszczalnia zagrodowa
nitryfikacja
denitryfikacja
wastewater treatment
constructed wetland plant
mountainous climate
farm house-hold wastewater
nitrification
denitrification
ground-vegetable filtration media
Opis:
Przedstawiono wyniki dwuletnich (2005-2006) badań instalacji do oczyszczania ścieków bytowych o wydajności do 1 m3/d, koncepcji IBMER w Tyliczu, składającej się z 3.komorowego osadnika o pojemności czynnej 6 m3, urządzenia ze zraszanym złożem z granulatu ilasto-gliniastego (keramzyt) o powierzchni 2,5 m2 i stokowego złoża glebowo-darniowego o powierzchni 61 m2. Wskaźniki całorocznej skuteczności oczyszczania ścieków w tej instalacji - przy średnim dobowym dopływie 655 l - były znacząco wyższe od obowiązujących wymagań, a niekorzystne warunki zimowe wpływały ujemnie jedynie na efektywność usuwania azotu całkowitego. Średnie wartości wskaźników skuteczności zmniejszania wielkości i stężeń badanych składników zanieczyszczeń wynosiły: 97,9/97,9% BZT5; 94,3/89,2% ChZT; 97,2/99,5% N-NH4; 60,5/78,5% N-NC; 84,4/84,3% P-PO4 (zima/lato). Konieczne jest dalsze technologiczne doskonalenie urządzeń instalacji w celu zwiększenia efektywności denitryfikacji ścieków.
Paper described the results of two-year investigations (2005-2006) of the sewage treatment in single farm purifying installation of treatment output 1 m3 per day. The installation consists of 3 chamber settling tank of 6 m3 active capacity, the plant with sprinkled bed of light expanded clay aggregates (keramzit) of about 2.5 m2 surface and the slope soil-turf filtration bed of 61 m2 surface. The indices of all-year long wastewater treatment effectiveness in tested installation - at average wastewater inflow 655 I per day - were significantly higher than the compulsory requirements, and severe winter conditions affected only the efficiency of total nitrogen removal. Average indices of reducing pollutants quantity and concentration in treated wastewater amounted to: 97.9/97.9% - BOD; 94.3/89.2% - COD; 97.2/99.5% N-NH4; 60.5/78.5% Ntot; 84.4/84.3% P-PO4 (winter/summer). Further technological improvements of the installation would be necessary to increase the efficiency of sewage denitrification.
Źródło:
Problemy Inżynierii Rolniczej; 2007, R. 15, nr 2, 2; 51-60
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie frakcji CHZT w ściekach surowych dopływających do małych i dużych oczyszczalni ścieków
Comparison of the fractions of cod in raw wastewater influent for small and large sewage treatment
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/401888.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
frakcje ChZT
małe oczyszczalnie ścieków
złoża biologiczne
oczyszczalnia hydrofitowa
oczyszczalnia z osadem czynnym
COD fractions
small sewage treatment plants
rotary biological contactor
constructed wetland
treatment with activated sludge
Opis:
W artykule przedstawiono porównanie udziału frakcji ChZT w ściekach surowych w oczyszczalniach do których spływają małe ilości ścieków oraz oczyszczalnię z dużym przepływem. Porównano oczyszczalnię hydrofitową o średniej przepustowości 4 dm3/m, oczyszczalnię ze złożami biologicznymi o średniej przepustowości 8 dm3/m, oraz oczyszczalnię ścieków z osadem czynnym w Białymstoku o przepustowości około 70 000 m3/d. Najniższe udziały procentowe frakcji rozpuszczonych związków biologicznie nierozkładalnych SI w ściekach surowych odnotowano w małych oczyszczalniach ścieków. Na podstawie dostępnych danych niestwierdzono istotnych zależności między frakcjami XI, SS, XS w ściekach surowych a ilością wytwarzanych ścieków.
The article presents a comparison of the share fraction of COD in raw wastewater in treatment plants which flow in a small amount of wastewater and the sewage treatment with high flow. Compared the constructed wetlands with an average capacity of 4 dm3/m,, the treatment plant with biological deposits with an average capacity of 8 dm3/m, and a sewage treatment plant with activated sludge in Bialystok with a capacity of about 70 000 dm3/m. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was reported in raw sewage in small sewage treatment plants. Based on the available data wasn’t found significant correlation between the factions XI, SS, XS in raw sewage and the amount of wastewater.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 191-195
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-41 z 41

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies