Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Więcek, B." wg kryterium: Autor


Tytuł:
Performance analysis of dual-band microbolometer camera for industrial gases detection
Autorzy:
Więcek, P.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114214.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wide-band microbolometer detector
IR spectral transmission and absorption
configuration factors
IR absorption of methane
Opis:
In this paper we present a simplified performance analysis of wide-band microbolometer cameras for gas detection. The spectral characteristics of camera’s elements such as detector, lens and filter were considered in this analysis. The parasitic radiation of IR filter that diminishes the contrast was included in the model. The exemplary results are presented for methane detection both in MWIR and LWIR bands of absorption
Źródło:
Measurement Automation Monitoring; 2018, 64, 4; 90-94
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie termografii w konserwacji zabytków
Thermovision applications for conservation of monuments
Autorzy:
Więcek, B.
Poksińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/155436.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia
konserwacja zabytków
thermovision
conservation of monuments
Opis:
W pracy przedstawiono podstawy i zastosowania termowizji w konserwacji zabytków. Opisano podstawy metody termowizji pasywnej i aktywnej do wykrywania defektów i identyfikacji struktur wielowarstwowych. Przestawiono system i oprogramowanie do rejestracji i przetwarzania obrazów. W programie zaimplementowano analizę częstotliwościową, która zapewnia przedstawienie sekwencji termogramów w postaci amplitudy i fazy. Pozwala to na lepszą interpretacę warstw złożonych struktur oraz łatwe wykrywanie defektów. Jako przykład w pracy przedstawiono wyniki badań termograficznych kościoła na zamku w Malborku.
Abstract - Applications of passive and active thermovision for conservation of monuments, especially architectural ones are presented in the paper. Basis of lock-in thermovision with the details of the system for nondestructive testing are described. The dedicated computer program has been created for image recording and processing. The function of frequency analysis is implemented in the program, allowing the display the sequence of images by its amplitude and phase. It give significant improvement of defects or multilayer structure interpretation. An example of application of this new measurement technique for investigation of the church in the castle of Malbork illustrates the presented method.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 3, 3; 7-10
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie pierścieni pośrednich w badaniach termowizyjnych
Application of extension tubes to thermographic measurements
Autorzy:
Kałuża, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/157676.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary termowizyjne
pierścień pośredni
obiektyw
thermographic measurements
extension tube
camera lens
Opis:
Kamery termowizyjne są od lat jednym z podstawowych narzędzi wykorzystywanych do badań zjawisk termicznych w wielu różnych dziedzinach nauki i techniki. Ze względu na wykorzystywane długości fal, najczęściej 3-5 Μm lub też 7-14 Μm, kamery termowizyjne nie mogą korzystać ze standardowych obiektywów ze szkła krzemowego. Konieczne jest stosowanie drogich elementów optycznych, wykonywanych np. z germanu lub też szafiru. Chcąc stosować kamerę termowizyjną do zróżnicowanych zadań, począwszy od obserwacji odległych przedmiotów, poprzez badania stanu izolacji termicznej budynków, badania maszyn i urządzeń, a kończąc na mikroskopowych badaniach elementów elektronicznych, konieczne staje się wyposażenie kamery termowizyjnej w cały zestaw obiektywów, począwszy od obiektywów teleskopowych, aż po obiektywy mikroskopowe. Celem badań opisanych w niniejszym artykule było sprawdzenie możliwości zastosowania w badaniach termowizyjnych pierścieni pośrednich.
Infrared cameras has been used for years as one of the main tools for temperature measurements. Because of wavelengths employed (3-5 Μm or 7-14 Μm), infrared cameras cannot use standard lenses made of silicon glass. It is necessary to rely on expensive optical materials such as germanium or sapphire. When using an infrared camera for different tasks, such as observation of distant objects, evaluation of buildings thermal insulation, thermal measurements of transformers, power lines, thermal investigations of electronic circuits, one has to use a wide range of lenses, from telescopic to microscopic. The goal of the research was to investigate the possibility of using extension tubes for thermography for imaging objects of sizes comparable to the detector matrix pixel pitch. The general problems of macrophotography are presented in the introduction. The second section describes the physical phenomena and effects to be taken into account when adding an extension tube to infrared camera lens which are the modification of the imaged object - lens - detector matrix geometry leading to the changes of the configuration factor; the influence of the radiation coming from the extension tube itself and finally, the problem of the imaged detail size becoming comparable to the wavelength used by the detector matrix. Next, in the third section, there are presented the results of measurements taken with a MWIR camera, using various combinations of 4 extension tubes. The fourth section contains the conclusions based on the presented measurement results. Extension tubes are an interesting alternative to microscopic lenses, especially in case of measurements for which only the signal phase is of interest. In general, extension tubes appear to be an interesting tool but it should be noted that the additional camera calibration may be needed when using them, depending on the tube length, the imaged object placement in relation to the lens axis and the measured object temperature in order to avoid temperature measurement errors.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 898-901
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cyfrowy system video termalny dla aplikacji w bliskim zasięgu
Autorzy:
Sawicki, P.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/130856.pdf
Data publikacji:
1998
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
system cyfrowy
kamera termowizyjna
digital system
thermovision camera
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 1998, 8; 13-1-13-9
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lokalizacja obszarów nieciągłości materiału ochronnego - symulacje komputerowe i badania eksperymentalne
Location of discontinuities in protective material - computer simulations and experimental tests
Autorzy:
Gralewicz, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/179105.pdf
Data publikacji:
2008
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
materiały ochronne
symulacje komputerowe
structure of the protective material
protective materials
computer simulation
Opis:
Materiały stosowane do produkcji wyrobów przeznaczonych do ochrony człowieka (m.in. materiały kompozytowe złożone z kilku warstw, zwane dalej materiałami ochronnymi) mają strukturę niejednorodną i anizotropową. Poprzez dobór odpowiednich składników można otrzymać materiał ochronny o odpowiednich parametrach i w ten sposób uzyskać np. wyższą odporność na udary lub lepsze pochłanianie energii. Właściwości materiału ochronnego zmieniają się, gdy w strukturze materiału pojawiają się (już podczas procesu technologicznego oraz na późniejszych etapach użytkowania) rozwarstwienia, pęcherzyki powietrza, pęknięcia itp. Ocena jakościowa struktury materiału ochronnego polega na wskazaniu defektów występujących w materiale. Do tego celu została wykorzystana technika termografii aktywnej. Termografia aktywna to metoda badań nieniszczących, w której badany obiekt pobudza się energią cieplną, a kamera termowizyjna mierzy zmienny w czasie rozkład temperatury. Ciepło w materiałach stałych rozchodzi się drogą dyfuzji, co jest ściśle powiązane z właściwościami termicznymi badanego materiału.
The structure of materials used in the production of components designed for personal protection (e.g. multi-layer composites, hereinafter called protective materials) is heterogeneous and anisotropic. By selecting suitable ingredients, protective materials of required parameters can be obtained, making it possible to achieve higher impact strength or enhanced energy absorption. The properties of protective materials change whenever the structure of the material (already during the technological process or at later application stages) features lamination, air bubbles, fractures, etc. A qualitative evaluation of protective material consists in identification of defects present in the material. To this aim, active thermography technology is employed.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2008, 11; 12-15
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Practical assessment of accuracy of thermographic indirect measurements
Autorzy:
Pacholski, K.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114508.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
errors and uncertainty
infra-red (IR) thermography
emissivity metallurgy
slag
Opis:
: In this paper, the basis of error and uncertainty assessment for thermographic measurement of temperature is presented. An engineering simplified analytical approach of determining the coverage coefficient is described for different number of thermal images taken into analysis and different contributions of A and B-type of uncertainties. In the form of an example, the entire procedure of uncertainty assessment was used for emissivity. The exemplary calculus are presented for emissivity in LWIR spectral range.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 278-281
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal modeling and RMS current measurement in electrical power lines using IR thermography
Autorzy:
Torzyk, B.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114450.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
RMS electrical current measurement
heat transfer modeling
overhead power lines
IR thermography
Opis:
Thermal modeling in frequency domain and experiments using IR thermography are performed to evaluate RMS current in electrical power lines. The model implements interface thermal resistance between the metal core and insulation layer. This allowed matching the results of simulations and measurements with acceptable accuracy. The proposed method requires the use of known values of heat transfer coefficient and thermal parameters of the cable and its insulation. In consequence the proposed method requires calibration.
Źródło:
Measurement Automation Monitoring; 2018, 64, 3; 53-56
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active Thermography in Qualitative Evaluation of Protective Materials
Autorzy:
Gralewicz, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/90338.pdf
Data publikacji:
2009
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
protective material
active thermography
defects
Opis:
This is a study of the possibilities of a qualitative evaluation of protective materials with active thermography. It presents a simulation of a periodic excitation of a multilayer composite material. Tests were conducted with lock-in thermography on Kevlar® composite consisting of 16 layers of Kevlar® fabric reinforced with formaldehyde resin with implanted delamination defects. Lock-in thermography is a versatile tool for nondestructive evaluation. It is a fast, remote and nondestructive procedure. Hence, it was used to detect delaminations in the composite structure of materials used in the production of components designed for personal protection. This method directly contributes to an improvement in safety.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2009, 15, 4; 363-371
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A simplified model of parasitic radiation in IR bolometer camera
Autorzy:
Strąkowski, R.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/973071.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radiation model
configuration factor
uncooled camera
residual non uniformity
heat exchange
Opis:
This article presents the impact of thermal radiation of the internal elements of the camera on temperature and its distribution on the bolometers of the Focal Plane Array. In order to estimate the effect of this component, a simplified radiation heat transfer model was created for the detector, the object and the camera housing. The model is based on the known term of radiation configuration factors. It was also suggested to use a radiation screen to isolate the detector from the influence of the camera housing. Finally, results of numerical simulations for different camera work conditions are presented.
Źródło:
Measurement Automation Monitoring; 2017, 63, 3; 94-97
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-cost IR system for thermal characterization of electronic devices
Autorzy:
Kopeć, M.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/114060.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal impedance
Foster network
thermal time constants
temperature measurement
Opis:
In this article, a Low-cost measurement Infra-Red (IR) system for dynamic thermal testing of electronic devices is described. The element is powered by a step-function current and simultaneously temperature is measured by a fast single-detector IR head. The thermal impedance Zth(jω) is calculated using the Laplace transform and the Foster network is to get thermal time constants distribution.
Źródło:
Measurement Automation Monitoring; 2018, 64, 4; 103-107
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie transformatora piezoelektrycznego z uwzględnieniem samonagrzewania
Modeling of a piezoelectric transformer when taking into consideration the self-heating
Autorzy:
Tomalczyk, K.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/157598.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator piezoelektryczny
modelowanie elektrotermiczne
piezoelectric transformer
electro-thermal modeling
Opis:
Artykuł wprowadza w temat zastosowania transformatorów piezoelektrycznych (PT) jako alternatywy dla powszechnych transformatorów z rdzeniem magnetycznym, omawia także najważniejsze problemy występujące przy projektowaniu układów zasilających opartych na PT, ze szczególnym uwzględnieniem zjawisk termicznych. W artykule przedstawiony jest nowy sprzężony model elektrotermiczny uwzględniający zależność częstotliwości rezonansowej od temperatury obliczanej na podstawie strat mocy. Model poprawnie odwzorowuje zjawisko samonagrzewania się PT podczas pracy w zmiennych warunkach w układzie przetwornicy.
Piezoelectric transformers (PTs) are high quality factor, high efficiency electrical energy transducers based on mechanical coupling between the primary and secondary side. Their power density levels as high as 50W/cm3 make them very promising alternative to traditional magnetic core transformers, primarily in terms of miniaturization and efficiency. There are, however, some problems slowing down their development, among which thermal management is one of the most important. A PT is a resonant transducer designed to work within an exactly determined narrow frequency range (Fig. 1). It can be modeled with use of a simple single-branch circuit model (Fig. 2) in which a series RLC connection correspond to the main resonance. Our research focuses on a prototype 40W step-down ring-shaped PT (Fig. 3) having the advanced multi-layer structure (Fig. 4). Its main resonance of approx. 322 kHz (Fig. 5) exhibits a tendency to move towards higher frequencies with temperature (Fig. 6). This can possibly induce an undesired positive thermal feedback leading to stability problems and thus should be included in modeling and simulation. We propose a simple coupled electro-thermal model (Fig. 7) in which the resonance frequency shift (Fig. 8) depends on the temperature rise calculated from power losses. Our model, contrary to the traditional isothermal one, allows simulating the self-heating phenomenon and its influence on the key waveforms of the PT working in a converter circuit (Fig. 9).
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 973-976
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja dryftu temperaturowego detektorów mikrobolometrycznych
Correction of microbolometer detector temperature drift (offset)
Autorzy:
Olbrycht, R.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/157672.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kamera termowizyjna
detektor mikrobolometryczny
NUC
niejednorodność
offset
dryft
korekcja
przysłona
migawka
thermovision camera
microbolometer detector
non-uniformity
drift
correction
aperture
shutter
Opis:
W pracy przedstawiono nową metodę wyznaczania dryftu temperaturowe-go (ang. offset) mikrobolometrycznych kamer termowizyjnych bez ko-nieczności stosowania migawki, która przesłania obserwowaną scenę. Zamiast migawki zastosowano półprzezroczystą przysłonę, która zmienia poziom energii docierającej do detektora. Metoda zakłada, że w czasie korekcji dryftu temperaturowego kamera "patrzy" na nieruchomy obiekt.
In this paper a new method of temperature drift compensation of microbolometer detectors is presented. Thermal cameras with such detectors are commonly used thanks to relatively low price, small dimensions and no requirement for cooling the detector. Regardless of the microbolometer type, there is a problem of detector temperature drift which is non-uniform over the detector surface. The problem is a result of very high thermal sensitivity of the microbolometer structure which is susceptible to heat coming from surrounding electronics. The most commonly used approach to deal with the problem of temperature drift is use of a mechanical shutter which periodically blocks the observation of scene for the time necessary to perform the correction. The principle of the presented method is based on using an aperture introduced periodically between the detector and the observed scene instead of the shutter. The detector response to the scene radiation with and without the aperture is recorded. Using equation (4), one can calculate the real amount of scene radiation, irrespective of the offset value introduced by the microbolometer temperature drift (equation (5)). This method enables a thermal camera to perform a live offset correction without using a shutter and without interruption of scene observation. Besides of theoretical information about the new method, chosen quantitative results of experiments realized at the Institute of Electronics, Technical University of Lodz are given (Figs. 4 and 5).
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 89-893
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu sygnału wymuszenia energetycznego na wynik analizy częstotliwościowej w technikach termografii aktywnej
Impact of energy excitation on frequency analysis for active thermography techniques
Autorzy:
Gralewicz, G.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/157695.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termografia
impuls
periodyczne wymuszenie
thermography
impulse
periodic energy excitation
Opis:
Przedstawione w pracy wyniki dotyczą badania wpływu rodzaju sygnału wymuszenia energetycznego na wynik analizy częstotliwościowej sekwencji obrazów termograficznych oraz zestawienia wyników analiz Fouriera i falkowej dla materiałów jednorodnych termicznie. Na podstawie przeprowadzonych doświadczeń popartych modelowaniem komputerowym określono wpływ sygnału wymuszenia energetycznego periodycznego i impulsowego na wynik analizy częstotliwościowej.
Results of the excitation energy impact on frequency analysis for active thermography techniques are presented. Active thermography is a non-destructive evaluation method (NDE) in which tested items are excited with heat excitation, while infrared camera measures the changes of temperature distribution in time. Heat spreads in solid materials through diffusion which is strongly dependent on the thermal qualities of the tested material. The investigations included computer simulation and experimental tests. The analysis results of different excitation (frequency and time) for testing thermally conductive and isolative materials while using impulse and periodic energy signals are presented. The comparison between the Fourier and wavelets analysis for thermally homogeneous materials is discussed. The authors defined a parameter phase difference K? for signature defect in materials whose maximum value indicates the frequency of heat excitation. For isolative materials its value is much larger (the larger the thickness of the material, the greater the value of phase angle), while for conductive ones it is smaller, hence it is difficult to locate a defect in the material. The results of the excitation energy impact on the frequency analysis showed that periodic energy is more advantageous for isolative materials, whereas impulse energy is more useful for conductive materials.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 11, 11; 902-905
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie termowizji w badaniach nieniszczących i w mikroelektronice
Application of Thermography in Non Destructive Testing and microelectronics
Autorzy:
Więcek, B. [et al.]
Powiązania:
https://bibliotekanauki.pl/articles/153907.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
badania nieniszczące
mikroelektronika
nondestructive testing
thermography
microelectronics
Opis:
W niniejszym artykule przedstawiono podstawowe zagadnienia jakimi zajmuje się Zespół Termografii Komputerowej Instytutu Elektroniki PŁ. Ponieważ zastosowania termowizji są bardzo ogromne i rosną, dlatego autorzy wybrali następujące zagadnienia, które są obecnie realizowane: projektowanie interfejsów do kamer termowizyjnych i integracja systemów, projektowanie radiatorów układów scalonych VLSI, wykorzystanie własności dynamicznych rur cieplnych w chłodzeniu układów elektronicznych. Przedstawione zostały również nowe zagadnienia, którymi zajmuje się zespół, takie jak badania nieniszczące z wykorzystaniem fali cieplnej jak również chłodzenie układów elektronicznych z wykorzystaniem pompy kapilarnej.
In this article, an overview of thermography applications developed in the Institute of Electronics, Technical University of Lodz are presented. The growing interest of thermography in various field of applications is observed. In the domain of scientific investigations, thermography is successfully applied for modelling cooling systems in microelectronics, including phase change solutions. Additionally, dynamic thermography is widely used in non destructive testing in material science. Thermal wave method and pulse thermography are applied.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 11, 11; 8-12
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rodzaju promiennika podczerwieni na skuteczność korekcji wzmocnienia matryc mikrobolometrycznych
Influence of infrared emitter on efficiency of gain correction in microbolometer detectors
Autorzy:
Olbrycht, R.
Więcek, B.
Powiązania:
https://bibliotekanauki.pl/articles/154577.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termowizja
mikrobolometr
promiennik
NUC
thermovision
microbolometer
infrared emitter
Opis:
Artykuł porusza problem korekcji współczynników wzmocnienia matryc mikrobolometrycznych w kamerach termowizyjnych przy użyciu promienników podczerwieni. Przedstawiona metoda nie wymaga używania dwóch modeli ciał doskonale czarnych. Nowością jest porównanie efektów uzyskiwanych przy użyciu dużego (pierścieniowego) i małego (punktowego) promiennika podczerwieni. Wskazano możliwość wystąpienia artefaktów w macierzy wyznaczanej przy użyciu małego promiennika, oraz stwierdzono ich brak podczas stosowania dużego promiennika.
The paper describes the problem of correcting microbolometer gain coefficients in thermal cameras. There is presented the reference approach (Section 2) which requires to record thermograms of two blackbody model surfaces in different temperatures [1, 2, 3]. The authors propose a different method (Section 3) [4, 5], which is based on using an infrared emitter built into the thermal camera (Fig. 2). The novelty in this paper is analysis of the dependence between the emitter size and correction efficiency. In particular, the comparison of small, spotlight emitter (Fig. 1a) and larger, toroidal one (Fig. 1b) is provided. For qualitative comparison of correction results, the matrices of the calculated gain correction factors are shown in Fig. 3. One may notice some artifacts in Fig. 3c (obtained with the small emitter). The quantitative analysis (namely, the calculated values of the root mean square error for centre regions of matrices) confirms the presence of artifacts. Also the histograms of the calculated matrices (Fig. 4) are in coherence with the above observations. The conclusion is that a large emitter is better for determination of gain correction factors with the proposed method (root mean square error was about 0,0096 in this particular case). In case of a small emitter the unwanted point artifacts may occur.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1127-1129
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies