Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kapłon, J." wg kryterium: Autor


Tytuł:
Electrospark alloying process with respect to the measurement of electrical quantities
Proces stopowania elektroiskrowego w aspekcie pomiarów wielkości elektrycznych
Autorzy:
Antoszewski, B.
Kapłon, A.
Rolek, J.
Powiązania:
https://bibliotekanauki.pl/articles/151976.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
proces stopowania elektroiskrowego
pomiary wielkości elektrycznych
electrospark alloying process
measurement of electrical quantities
Opis:
The work is concerned with a physical model of the electrospark alloying process. It discusses the complexity of measurement of electrical quantities describing an electrospark discharge. The aim of the investigation is to determine the relationship between pulse energy and the amount of a deposit constituting a coating.
W opracowaniu na tle modelu fizycznego procesu stopowania elektroiskrowego przedstawiono złożoność problemów pomiarowych wielkości elektrycznych opisujących wyładowanie elektroiskrowe. Celem tych badań jest w dalszej perspektywie określenie relacji pomiędzy energią impulsu a masą materiału tworzącą powłokę.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 6, 6; 9-11
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GPU Accelerated Image Reconstruction in a Two-Strip J-PET Tomograph
Autorzy:
Białas, P.
Kowal, J.
Strzelecki, A.
Bednarski, T.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402623.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
Opis:
We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1500-1504
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An assessment of the quality of near-real time GNSS observations as a potential data source for meteorology
Autorzy:
Dymarska, N.
Rohm, W.
Sierny, J.
Kapłon, J.
Kubik, T.
Kryza, M.
Jutarski, J.
Gierczak, J.
Kosierb, R.
Powiązania:
https://bibliotekanauki.pl/articles/108476.pdf
Data publikacji:
2017
Wydawca:
Instytut Meteorologii i Gospodarki Wodnej - Państwowy Instytut Badawczy
Tematy:
ZTD estimation
data validation
GNSS meteorology
Opis:
The Global Navigation Satellite System (GNSS) can be used to determine accurate and high-frequency atmospheric parameters, such as Zenith Total Delay (ZTD) or Precipitable Water Vapour (PW), in all-weather conditions. These parameters are often assimilated into Numerical Weather Prediction (NWP) models and used for nowcasting services and climate studies. The effective usage of the ZTDs obtained from a ground-based GNSS receiver’s network in a NWP could fill the gap of insufficient atmospheric water vapour state information. The supply of such information with a latency acceptable for NWP assimilation schemes requires special measures in the GNSS data processing, quality control and distribution. This study is a detailed description of the joint effort of three institutions – Wrocław University of Environmental and Life Sciences, Wrocław University, and the Institute of Meteorology and Water Management – to provide accurate and timely GNSS-based meteorological information. This paper presents accuracy analyses of near real-time GNSS ZTD validated against reference ZTD data: the International GNSS Service (IGS) from a precise GNSS solution, Weather Research and Forecasting (WRF) model, and radiosonde profiles. Data quality statistics were performed for five GNSS stations in Poland over a time span of almost a year (2015). The comparison of near real-time ZTD and IGS shows a mean ZTD station bias of less than 3 mm with a related standard deviation of less than 10 mm. The bias between near real-time ZTD and WRF ZTD is in the range of 5-11 mm and the overall standard deviation is slightly higher than 10 mm. Finally, the comparison of the investigated ZTD against radiosonde showed an average bias at a level of 10 mm, whereas the standard deviation does not exceed 14 mm. Considering the data quality, we assess that the NRT ZTD can be assimilated into NWP models.
Źródło:
Meteorology Hydrology and Water Management. Research and Operational Applications; 2017, 5, 1; 3-13
2299-3835
2353-5652
Pojawia się w:
Meteorology Hydrology and Water Management. Research and Operational Applications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki wymiany ciepła podczas cienkowarstewkowego odparowania roztworów wody w cieczy jonowej OMIM[Cl]
Heat transfer conditions during thin-layer evaporation of water - OMIM[Cl] ionic liquid solutions
Autorzy:
Dziak, J.
Kapłon, J.
Królikowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/2072413.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ciecz jonowa
roztwór
wyparka cienkowarstewkowa
ionic liquid
solution
film evaporator
Opis:
Przedstawiono wyniki badań wymiany ciepła podczas odparowania roztworów woda-ciecz jonowa OMIM[Cl] w wyparce cienkowarstewkowej z mechanicznie rozcieranym filmem cieczy. Określono zależności współczynnika wnikania ciepła od: intensywności zraszania powierzchni grzejnej wyparki, obciążenia cieplnego, obrotów mieszadła. Warunki wymiany ciepła przy zatężaniu roztworów cieczy jonowych dotychczas nie były badane i brak jest danych projektowych na temat możliwości ich regeneracji.
Results dealing with evaporation of water - OMIM[Cl] ionic liquid solutions carried out in a wiped film evaporator are presented in the paper. The dependencies between the individual heat transfer coefficient and liquid flow rate, heat load and mixing arm rotational frequency were elaborated. So far, such data are not available in literature, and therefore the results presented by the authors should help in designing of ionic liquid regeneration process.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 304--305
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie współczynników wnikania masy podczas odparowania cienkowarstewkowego roztworu przy wykorzystaniu wyników destylacji lub wyników badań ruchu ciepła
Determination of mass transfer coefficients during the thin-layer solution evaporation using distillation or heat transfer results
Autorzy:
Dziak, J.
Kubala, M.
Kapłon, J.
Ludwig, W.
Powiązania:
https://bibliotekanauki.pl/articles/2070877.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyparka cienkowarstewkowa
roztwór
ruch ciepła
ruch masy
thin-layer evaporator
liquid solutions
heat and mass transfer
Opis:
W pracy przedstawiono wyniki badań eksperymentalnych ruchu ciepła i masy podczas odparowania cieczy w wyparce cienkowarstewkowej. Wyznaczono współczynniki wnikania ciepła podczas wrzenia cieczy jednoskładnikowych i roztworów. Wyniki destylacji w układzie alkohol izopro-pylowy - woda porównano z wynikami obliczeń teoretycznych. Stwierdzono wyraźne różnice. Wyznaczono wartości współczynników wnikania masy podczas wrzenia roztworu. Zastosowano dwie różne metody postępowania. Uzyskano podobne wyniki.
Results of experimental investigations on heat and mass transfer during liquid evaporation in a thin-layer evaporator are presented. Individual heat transfer coefficients were determined. The results of distillation of isopropyl alcohol - water solutions were obtained. Significant deviations of theoretical results in comparison with experimental ones were confirmed. Individual mass transfer coefficients were determined applying two different methods. Both methods gave similar results.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 2; 37-38
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena dokładności danych uzyskanych z pomiaru batymetrycznego wykonanego echosondą Lowrance LMS-527C DF iGPS
Evaluation of data accuracy obtained from bathymetric measurement using fishfinder Lowrance LMS-527C DF iGPS
Autorzy:
Gołuch, P.
Dombek, A.
Kapłon, J.
Powiązania:
https://bibliotekanauki.pl/articles/131139.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
batymetria
numeryczny model terenu
bathymetry
digital terrain model (DTM)
Opis:
W pracy autorzy przeprowadzili analizy dokładności danych, uzyskanych w wyniku wykonanego sondażu hydroakustycznego za pomocą jednowiązkowej echosondy ultradźwiękowej LMS-527C DF iGPS firmy Lowrance Electronics, Inc. Lokalizacja punktów sondowania była przeprowadzona na dwa sposoby: wykorzystano 12-kanałowy GPS wbudowany w echosondę oraz niezależnie sprzęt do pomiarów geodezyjnych – zastosowano w drugim przypadku technikę pomiarową GPS–RTK (Real Time Kinematic), umożliwiającą precyzyjne wyznaczenie pozycji w czasie rzeczywistym. Pomiar terenowy przeprowadzono w lipcu 2009 roku na Zbiorniku Pilchowickim, który znajduje się w górnej części rzeki Bóbr, niedaleko Jeleniej Góry. Prace terenowe wykonane zostały przez pracowników Instytutu Geodezji i Geoinformatyki Uniwersytetu Przyrodniczego we Wrocławiu. Ocena dokładności opierała się na analizie wyznaczonych współrzędnych płaskich XY, pomierzonych głębokości D oraz otrzymanych współrzędnych przestrzennych XYH. W rezultacie przeprowadzonych analiz wyznaczono dokładność wykonanego pomiaru. Stwierdzono, że za pomocą systemu GPS wbudowanego w odbiornik echosondy można wyznaczyć pozycję XY przetwornika echosondy z średnim błędem na poziomie 4.2 m (dokładność ta jest niejednorodna i zmienia się w czasie). Sondaż hydroakustyczny przy pomocy zastosowanej echosondy ultradźwiękowej oraz odbiornika GPS w niej wbudowanego (przy założeniu, że znany jest poziom zwierciadła wody) pozwala na pozyskanie danych batymetrycznych z dokładnością na poziomie 0.20 m. Natomiast, gdy do pozycjonowania przetwornika echosondy wykorzystano technikę pomiarową GPS-RTK (w przypadku znanego i nieznanego poziomu zwierciadła wody), otrzymano dokładność pomiaru głębokości na poziomie 0.13 m. Obliczenia przeprowadzono w środowisku Scilab.
The authors carried out an analysis of the accuracy of data obtained from a hydroacoustic survey performed with the ultrasonic sonar LMS-527C DF and GPS Company Lowrance Electronics, Inc. The location of probing points was carried out in two ways: using an 12-channel GPS built-in echo s ounder and, independently, a surveying equipment. In the second case, the measuring technique GPS-RTK (Real Time Kinematic)was used enabling accurate position determination in real time. The field measurement was conducted in July 2009 at Pilchowice Reservoir, which is located in the upper part of the Bóbr River near Jelenia Góra. Fieldwork was carried out by the staff of the Institute of Geodesy and Geoinformatics, University of Life Sciences in Wroclaw. Assessment of accuracy was based on analysis of the determined coordinates in XY plane, measured depth D and obtained spatial coordinates XYH. As a result of the analysis, the accuracy of the measurements was determined. It was found that using a built-in GPS receiver the position of the sonar transducer XY could be determined with an average error of 4.2 m (accuracy is heterogeneous and changes with time). Hydroacoustic survey with an ultrasonic sonar and a GPS receiver embedded in it (assuming that thelevel of water table is known) can provide bathymetric data of an accuracy of 0.20 m. However, if for sonar transducer positioning the measuring technique GPS-RTK was used, (with known or unknown water level), the depth measurement accuracy was at a level of 0.13 m. The calculations were performed in the Scilab environment.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2010, 21; 109-118
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zrównoważenie produkcji rolniczej w wybranych gospodarstwach województwa małopolskiego
Sustainability of production in selected agricultural holdings in the Malopolska province
Autorzy:
Kania, J.
Kaplon, A.
Powiązania:
https://bibliotekanauki.pl/articles/864278.pdf
Data publikacji:
2014
Wydawca:
The Polish Association of Agricultural and Agribusiness Economists
Opis:
Dokonano analizy zrównoważenia produkcji w wybranych gospodarstwach województwa ma- łopolskiego o mieszanych typach rolniczych i wskazano te kierunki produkcji, które ułatwiają osiągnięcie jej zrównoważenia w aspekcie środowiskowym, ekonomicznym i społecznym. Najlepiej zrównoważoną produkcję pod względem ekologicznym prowadziły gospodarstwa o zróżnicowanym chowie zwierząt, a pod względem ekonomicznym gospodarstwa ze zróżnicowanymi uprawami. W badanych gospodarstwach przyjęte kryterium społeczne nie stanowiło bariery zrównoważenia produkcji.
The paper presents an analysis of the production sustainability in selected 107 agricultural holdings of Malopolska Provence with following general types of farming: mixed cropping, mixed livestock and mixed crops-livestock. In production sustainability were included different indicators of environmental, economic and social sustainability. Research results shows that top sustainable production of ecologically led holdings with mixed livestock, but economic criteria were reached in the greatest percentage by holdings with mixed cropping. The proposed social sustainability criterion in surveyed holdings was not a barrier to sustainable production.
Źródło:
Roczniki Naukowe Stowarzyszenia Ekonomistów Rolnictwa i Agrobiznesu; 2014, 16, 4
1508-3535
2450-7296
Pojawia się w:
Roczniki Naukowe Stowarzyszenia Ekonomistów Rolnictwa i Agrobiznesu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimators of induction motor electromechanical quantities built on the basis of a machine secondary multi-loop equivalent circuit
Autorzy:
Kaplon, A.
Utrata, G.
Rolek, J.
Powiązania:
https://bibliotekanauki.pl/articles/141081.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical machines
induction motor
sensorless control
estimation
Opis:
Contemporary sensorless AC drives require the use of electromechanical quantities estimation. The skin effect occurring in AC machines with solid secondary or with solid secondary elements causes machines of this type to be represented by equivalent circuits containing distributed elements, which makes the analysis of machine electrodynamic states more complicated and hinders the construction of relatively simple and effective estimators of electromechanical quantities. The variability of rotor parameters is modelled, with a good approximation, by the machine secondary multi-loop equivalent circuit with lumped elements. In this paper the construction procedure of electromechanical state variable estimators basing on this type of equivalent circuit will be presented. The simulation investigations of the created electromechanical quantities estimators, performed for the selected states of solid iron rotor AC machine operation will be shown as well.
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 149-160
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sekcja Narciarska „Warta” Oddziału Polskiego Towarzystwa Tatrzańskiego „Beskid Śląski” w Cieszynie w latach 1920 (1921)-1950
„Warta” Ski Section of the Branch of the Polish Tatra Association „Beskid Slaski” in Cieszyn during the 1920(1921)-1950
Autorzy:
Kaplon, J.
Powiązania:
https://bibliotekanauki.pl/articles/4740.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
narciarstwo
sport
historia
Polska
wiek XX
Polskie Towarzystwo Tatrzanskie
Polski Zwiazek Narciarski
lata 1920-1950
Kozdon Gustaw
Tajner Leopold
Opis:
Powstałe w 1873 roku Galicyjskie TT, w kilka miesięcy po powstaniu przemianowane na Towarzystwo Tatrzańskie, a po uzyskaniu przez Polskę niepodległości – na Polskie Towarzystw Tatrzańskie, już na początku XX wieku w sposób zorganizowany zajęło się propagowaniem narciarstwa, tworząc w 1907 roku Zakopiański Oddział Narciarzy, który w 1911 roku stał się Sekcją Narciarską Towarzystwa Tatrzańskiego. W niedługim czasie zaczęły powstawać sekcje narciarskie przy lokalnych oddziałach Towarzystwa. W roku 1920 zarząd jednego z nich – Oddziału „Beskid Śląski” z siedzibą w Cieszynie – powołał do życia swoją Sekcję Narciarską, nadając jej nazwę „Watra”. Sekcja działała w ramach tego oddziału do 1950 roku, a następnie kontynuowała swoją działalność w strukturach Oddziału PTTK „Beskid Śląski” w Cieszynie. W czasie funkcjonowania w strukturach Polskiego Towarzystwa Tatrzańskiego działacze Sekcji przeprowadzili niezliczoną ilość kursów, szkoleń i wycieczek, dzięki czemu SN „Watra” stała się jedną z najważniejszych sekcji w tym Towarzystwie. Zajmowała się nie tylko propagowaniem turystyki narciarskiej w górach, podejmowała także działania zmierzające do rozwoju narciarstwa sportowego. Szkolenie kolejnych pokoleń narciarzy, uczestnictwo i organizacja licznych zawodów narciarskich oraz budowa skoczni narciarskich i jednej z pierwszych narciarskich tras zjazdowych (z Czantorii w Beskidzie Śląskim) stanowią trwały dorobek polskiego narciarstwa. Wśród zawodników SN największe sukcesy osiągnął Leopold Tajner, olimpijczyk, wielokrotny mistrz Polski w różnych kategoriach wiekowych w biegach i skokach narciarskich.
Established in 1873 the Galician Tatra Society, a few months later adopted name the Tatra Society, and finally, after the creation of independent Polish state – the Polish Tatra Society, at the beginning of the twentieth century formally organized Polish skiing movement, in 1907 forming the Zakopane Skiing Branch, which in 1911 became the Ski Section of the Tatra Society. In a short time ski sections of local branches of the Tatra Society began to emerge. In 1920, the board of one of them –the “Beskid Śląski” Branch from Cieszyn, brought to life its skiing section called the "Watra”. This section was active within the scope of the “Beskid Śląski” Branch until 1950, and is still active as a part of the Polish Tourist and Sightseeing Society in Cieszyn. Members of the “Watra” conducted countless activities: courses, seminars and excursions, making this ski sections one of the most important between ski sections of the Polish Tatra Society. It was not only promoting ski tourism in the mountains, but also has taken measures to develop competitive skiing. Training successive generations of skiers, participation in and organization of numerous ski competitions and construction of ski jumps and also one of the first downhill ski slopes (Czantoria in the Silesian Beskid) is the lasting achievement of “Watra”. Among its accomplished members is Leopold Tajner, multiple champion in different age categories in cross-country and ski jumping and Winter Olimpics participant.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Kultura Fizyczna; 2014, 13, 2
1895-8680
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Kultura Fizyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie własciwości cieplno-dyfuzyjnych liofilizowanych produktów spożywczych
Autorzy:
Kaplon, J.
Kramkowski, R.
Berdzik, M.
Powiązania:
https://bibliotekanauki.pl/articles/797152.pdf
Data publikacji:
1998
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Opis:
Przedstawiono eksperymentalne wyniki suszenia sublimacyjnego. Suszono wodne roztwory odtłuszczonego mleka pod różnymi ciśnieniami. Określano rozkłady temperatury i wilgotności w funkcji czasu suszenia. Stosowano jednostronne, radiacyjne ogrzewanie materiału. Na podstawie wyników eksperymentów i sublimacyjnego modelu URIF wyznaczono współczynniki przewodzenia ciepła i współczynniki dyfuzji pary wodnej w suchej warstwie.
Experimental results of vacuum freeze drying have been presented. Aqueous solutions of skim milk were dried under different pressures, determining the distribution of temperature and moisture as a function of drying time. Unilateral radiant heating of the materials was applied. On the grounds of experimental results and vacuum freeze drying model URIF the thermal conductivity and vapour diffusion coefficients in dry layer were determined.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 1998, 454, 2
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiple Scattering and Accidental Coincidences in the J-PET Detector Simulated Using GATE Package
Autorzy:
Kowalski, P.
Moskal, P.
Wiślicki, W.
Raczyński, L.
Bednarski, T.
Białas, P.
Bułka, J.
Czerwiński, E.
Gajos, A.
Gruntowski, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, Sz.
Pałka, M.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wochlik, I.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402625.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
Novel positron emission tomography system, based on plastic scintillators, is developed by the J-PET collaboration. In order to optimize geometrical configuration of built device, advanced computer simulations are performed. Detailed study is presented of background given by accidental coincidences and multiple scattering of gamma quanta.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1505-1512
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyparki cienkowarstewkowe i krótkodrożne w przemyśle spożywczym
Autorzy:
Kramkowski, R.
Kaplon, J.
Powiązania:
https://bibliotekanauki.pl/articles/809755.pdf
Data publikacji:
1998
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Opis:
Przedstawiono wyniki badań nad wnikaniem ciepła i masy w aparatach cienkowarstewkowych i krótkodrożnych przeznaczonych do zagęszczania substancji nieodpornych termicznie. Przedstawiono również wyniki badań nad zastosowaniem wyparek krótkodrożnych i cienkowarstewkowych w wybranych technologiach.
A considerable amount of substances in food industry are unstable to heat due to their sensitive and complex structure. Therefore, particular conservative conditions must be observed when they are thickened or refined. These requirements are fulfilled by thin-film and short-path evaporators, which ow ing to their design and operation ensure short time of stay in zone of raised temperature and practically enable unrestricted possibility of pressure reduction. Results of investigation on heat and mass transfer in such type of apparatuses and systems combined with them have been presented as well as results of tests with use of thin-film evaporators in certain technologies. Besides, there is discussed the use of short-path evaporators in three-stage installations for obtention of high-percentage edible monoglycerides. The paper includes a survey of the most modern apparatus solutions in this field.
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 1998, 454, 2
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Framework for the J-PET Scanner
Autorzy:
Krzemień, W.
Gajos, A.
Gruntowski, A.
Stola, K.
Trybek, D.
Bednarski, T.
Białas, P.
Czerwiński, E.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402621.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
29.85.-c
Opis:
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1491-1494
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hit Time and Hit Position Reconstruction in the J-PET Detector Based on a Library of Averaged Model Signals
Autorzy:
Moskal, P.
Sharma, N.
Silarski, M.
Bednarski, T.
Białas, P.
Bułka, J.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, L.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Wochlik, I.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402622.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.uk
07.05.Kf
Opis:
In this article we present a novel method of hit time and hit position reconstruction in long scintillator detectors. We take advantage of the fact that for this kind of detectors amplitude and shape of registered signals depend strongly on the position where particle hits the detector. The reconstruction is based on determination of the degree of similarity between measured and averaged signals stored in a library for a set of well-defined positions along the scintillator. Preliminary results of validation of the introduced method with experimental data obtained by means of the double strip prototype of the J-PET detector are presented.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1495-1499
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument
Autorzy:
Raczyński, L.
Moskal, P.
Kowalski, P.
Wiślicki, W.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Rudy, Z.
Salabura, P.
Gupta-Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/146280.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
compressed sensing
positron emission tomography
time-of-flight
Opis:
Nowadays, in positron emission tomography (PET) systems, a time of fl ight (TOF) information is used to improve the image reconstruction process. In TOF-PET, fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten signifi cantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to compressive sensing (CS) theory, information about the shape and amplitude of the signals is recovered. In this paper, we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50-ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.
Źródło:
Nukleonika; 2016, 61, 1; 35-39
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies