Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "surge arresters" wg kryterium: Wszystkie pola


Wyświetlanie 1-17 z 17
Tytuł:
Thermographic and Electrical Test of Medium Voltage Surge Arresters
Autorzy:
Lisowska-Lis, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/114064.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surge arresters
medium voltage
thermography
discharge current
cooling
Opis:
The paper presents the results of a thermal test (conducted with thermographic camera, coupled with an electrical test) of medium voltage metal–oxide surge arresters. Surge arresters (for Uc=18 kV) were tested for the leakage current and surface temperature: for 5 minutes under state 50 Hz alternating voltage 18 kV. The surface temperature of the MOAs correlates with an increase in leakage current. The result shows that the 0.6 mA AC leakage current in the medium voltage metal–oxide surge arrester (18 kV) is above the stable operating point, and the loss of electrical power is higher than the effective heat dissipation in the arrester. After 5 minutes of high voltage impact U = 18 kV, the surface temperature of the surge arrester was (4.32±0.55) K higher than the initial temperature. The IR camera can be used to detect the faults of ZnO metal–oxide surge arresters that lead to an increase in surface temperature.
Źródło:
Measurement Automation Monitoring; 2019, 65, 2; 60-63
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Degradation Processes in Shield-Centring Elements of Surge Arresters
Autorzy:
Papliński, P.
Śmietanka, H.
Ranachowski, P.
Ranachowski, Zbigniew
Wieczorek, K.
Kudela, S. jr.
Powiązania:
https://bibliotekanauki.pl/articles/2203744.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surge arrester
TSE glass textolite
discharge current
EDS method
Opis:
This paper presents the results of testing samples of shield-centering elements from medium-voltage surge arresters. The elements were made of TSE glass textolite. The elements have been dismantled from different operated surge arresters, which were subjected to discharge currents (short-circuit currents) of different intensity and duration. The discharge currents led to degradation of the tested elements with various degrees of advancement. The degradation was investigated using microscopic methods and energy-dispersive X-ray spectroscopy (EDS). Changes in the content of elements of the surface of textolite materials - as the degradation progresses - were documented. It was found that high discharge current flows resulted in melting of the organic binder, epoxy resin, especially its surface layer. Partial charring and even burning of the resin was noticeable. Furthermore, it was found that with increasing degradation on the surface of the TSE laminate, the carbon and oxygen content, which are part of the organic resin, decreases. Simultaneously the amount of silicon, calcium and aluminium, which are present in the glass fibres, increases. The charring effect of the resin and the formation of conductive paths result in a decrease in the performance of surge arresters and their subsequent failure.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 1; 237--242
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody diagnostyczne ograniczników przepięć
Diagnostics methods of metal oxide surge arresters
Autorzy:
Chrzan, K.
Powiązania:
https://bibliotekanauki.pl/articles/157473.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metody diagnostyczne
ograniczniki przepięć
diagnostic methods
metal oxide surge arresters
Opis:
Opisano najważniejsze metody diagnostyczne ograniczników przepięć: pomiaru temperatury sondami TINYTALK lub SAW, kompensacji, pomiaru prądu całkowitego, harmonicznych prądu i składowej rezystancyjnej prądu.
The most important diagnostic methods of metal oxide surge arresters were described: temperature measurement using TINYTALK sensors or SAW sensors (Surface Acoustic Wave), compensation method, total current measurement, current harmonics measurement and resistive current measurement.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 4, 4; 14-16
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagrożenie pożarowe oraz porażeniowe pochodzące od ograniczników przepięć SPD = Fire and shock hazard from SPD surge arresters
Fire and shock hazard from SPD surge arresters
Autorzy:
Wiatr, Julian.
Powiązania:
Zeszyty Naukowe SGSP 2017, nr 63, s. 59-71
Współwytwórcy:
Jaskółowski, Waldemar. Autor
Data publikacji:
2017
Tematy:
Bezpieczniki
Instalacje elektryczne
Ochrona przeciwpożarowa
Pożar
Przepięcie
Rażenie prądem elektrycznym
Artykuł z czasopisma naukowego
Opis:
Bibliografia na stronie 71.
Dostawca treści:
Bibliografia CBW
Artykuł
Tytuł:
Diagnostyka niskonapięciowych warystorowych ograniczników przepięć
Diagnostics of low voltage surge arresters
Autorzy:
Olesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/268637.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ograniczniki przepięć niskiego napięcia
warystory ZnO
diagnostyka
low voltage ZnO arresters
diagnostics
Opis:
W referacie przedstawiono stosowane w praktyce metody oceny stanu ograniczników przepięć niskiego napięcia (nn). Zestawiono wyniki pomiarów, które umożliwiły określenie stanu technicznego nowych i eksploatowanych ograniczników niskiego napięcia w zakresie charakterystyki przedprzebiciowej.
The paper presents some practical methods of technical state of low voltage ZnO surge arresters evaluation. Several methods of laboratory diagnostics and on - site checks were described. The analysis of commonly applied diagnostic methods was supplied by the results of leakage current measurements for new and degradated in exploitation low voltage arresters.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 113-116
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Studies on Degradation of Varistors Subjected to Operation in Surge Arresters and Surge Arrester Counters
Autorzy:
Papliński, P.
Wańkowicz, J.
Śmietanka, H.
Ranachowski, P.
Ranachowski, Z.
Kudela, S. jr.
Aleksiejuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/351611.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surge arrester
surge arrester counter
MO varistor
microstructure of ceramics
ceramic material degradation
Opis:
The paper presents results of investigation of microstructure and micro-hardness for material of ZnO varistors applied to 110 kV surge arrester and surge arrester counter. The research combined two pairs of varistors, each consisted of one varistor subjected before to operation, while the other one was brand new unit and constituted a reference. All varistors were made of the same material by the reputable manufacture. The tests revealed a different degree of the material degradation for varistors subjected before to operation. This also refers to different degradation mechanism observed for the material of these varistors, if typical effects of degradation of aged ZnO varistors were considered as a reference. Physical state of spinel in the microstructure had a significant impact on the material degradation, however a considerable loosening of the microstructure associated with bismuth oxide was observed too. It was surprising, since the precipitates of the bismuth oxide phase most often showed very good binding to the ZnO matrix and high resistance to associated electrical, thermal and mechanical effects. The degradation effects in the ZnO matrix proved to be limited only.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 1; 367-374
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure and Degree of Degradation of ZnO Varistors in Surge Arresters Due to Operation
Autorzy:
Papliński, P.
Wańkowicz, J.
Ranachowski, P.
Ranachowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/356415.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surge arrester
MO varistor
microstructure of ceramics
ceramic material degradation
Opis:
The paper presents the test results for the microstructure of ZnO varistors comprising high voltage gapless surge arresters. The tests were performed on varistors produced in different periods and by various manufacturers. The research was inspired by different characteristics of changes in values of current flowing through surge arresters as a function of changes in values of system voltage in a 220 kV substation, and the temperature in a multi-year cycle. Furthermore, the effects of varistor microstructure degradation following a failure of an unsealed surge arrester were investigated. The results provided the grounds for assessment of ZnO varistor microstructure parameters in terms of their durability and resistance to degradation processes.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 3; 1267-1273
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagrożenie pożarowe oraz porażeniowe pochodzące od ograniczników przepięć SPD
Fire and shock hazard from SPD surge arresters
Autorzy:
Wiatr, J.
Jaskółowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/136564.pdf
Data publikacji:
2017
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
ogranicznik przepięć SPD
zagrożenie pożarowe
instalacje elektroenergetyczne
pożar
surge arrester SPD
fire hazard
electrical installations
fire
Opis:
Bezpieczeństwo pożarowe jest jednym z najważniejszych wymagań stawianych współczesnym budynkom. Wiąże się z nim szereg wymagań technicznych, które należy spełnić na etapie projektowania. O poziomie bezpieczeństwa pożarowego decyduje m.in. jakość materiałów budowlanych, a także jakość i poziom zabezpieczenia instalacji elektroenergetycznej. Ograniczniki przepięć odgrywają istotną rolę w instalacjach elektroenergetycznych. Ich zadaniem jest ochrona przed przepięciami w urządzeniach elektrycznych i elektronicznych. Mogą one stwarzać zagrożenie pożarowe lub wybuchowe wskutek przepływu prądu następczego pojawiającego się bezpośrednio po wystąpieniu przepięcia. Tak sytuacja będzie miała miejsce, gdy nieprawidłowo zostanie dobrane zabezpieczenie poprzedzające lub/i ogranicznik zostanie przyłączony do głównego toru zasilającego przewodem o zbyt małym przekroju. W artykule autorzy prezentują charakterystykę dwóch stosowanych ograniczników: iskiernikowych i warystorowych, a także wytyczne do ich prawidłowego doboru.
Appropriate level of fire safety is one of the most important requirements for present-day buildings. There are plenty of technical conditions to be fulfilled during the design stage. Among factors influencing fire safety, the following should be mentioned: the quality of construction materials, but also the quality and level of electric installation protection. Lightning arresters play a significant role in the electric installation protection concept. Their role is to protect both electrical and electronic devices from too high voltage. On the other had, they might pose fire and explosion danger, as high current will flow through the arrester immediately after the overvoltage. This situation will take place, if the arrester circuit has been inappropriately designed by using not proper devices, or using wires of too low cross section, especially if the arrester was connected to main power supply. The article presents the characteristics of two commonly used lightning arresters: varistor-based and spark gap, as well as the guidelines of their appropriate design.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2017, 3, 63; 59-71
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania z zakresu ochrony odgromowej wykonane na Politechnice Wrocławskiej
Lightning protection research carried out at Wroclaw university of technology
Autorzy:
Chrzan, K.L.
Powiązania:
https://bibliotekanauki.pl/articles/267395.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
zwody aktywne
ogranicznik przepięć
gapped surge arresters
metal oxide surge arresters
early streamer emission terminals
Opis:
Wymieniono pierwsze instalacje piorunochronów w Rzeczypospolitej i na Dolnym Śląsku. Opisano badania skuteczności zwodów pionowych na makiecie obserwatorium meteorologicznego oraz skuteczności zwodów aktywnych ESE. Przedstawiono najważniejsze osiągnięcia w zakresie badania odporności zabrudzeniowej odgromników zaworowych i ograniczników beziskiernikowych. Streszczono pomiary wytrzymałości udarowej zabrudzonych izolatorów.
The first installation of Franklin rods in Kingdom of Poland and in Silesia Province were listed. The investigation of Franklin rods efficacy and inefficacy of early streamer emission terminals were shown. The most important achievements in the research of pollution resistance of gapped and gapless surge arresters was reported. The measurements of lightning flashover voltage of polluted insulators were described.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 29-34
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania odporności ograniczników przepięć stosowanych w kolejowych układach elektronicznych
Research immunity of surge arresters used in railway electronic systems
Autorzy:
Białek, K.
Powiązania:
https://bibliotekanauki.pl/articles/310247.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
kompatybilność elektromagnetyczna
odporność
udary
ograniczniki przepięć
electromagnetic compatibility
immunity
surges
surge arresters
Opis:
W artykule przedstawiono badanie odporności na udary elektryczne wybranych dwóch ograniczników przepięć stosowanych w kolejowych układach elektronicznych. Przedstawiono metodykę pomiarową, stanowisko laboratoryjne wg normy PN-EN 61000-4-5 oraz dopuszczalne poziomy narażeń zawarte w normie kolejowej PN-EN 50121-3-2. W artykule zaprezentowano przykładowe wyniki badań oraz przeprowadzono ocenę otrzymanych wyników według obowiązujących unormowań.
The article presents the test of immunity to electric surges of two surge arresters used in railway electronic systems. Metering methodology, laboratory stand according to PN-EN 61000-4-5 and exposure levels included in the railway standard PN-EN 50121-3-2 are presented. The article presents examples of research results and an evaluation of the obtained results according to the applicable regulations.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 308-311
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury warystorowych ograniczników przepięć ZnO na prądy upływowe
Effect of temperature on the leakage current of metal oxide surge arresters
Autorzy:
Olesz, M.
Powiązania:
https://bibliotekanauki.pl/articles/267980.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ograniczniki przepięć ZnO
prąd upływowy
wpływ temperatury
surge arresters
leakage current
influence of temperature
Opis:
W artykule omówiono wyniki pomiarów charakterystyk prądowo-napięciowych w zakresie prądu upływowego warystorowych ograniczników przepięć z tlenku cynku ZnO dla temperatur w zakresie 263 K ÷ 373 K. Badania wykonano w celu stwierdzenia powtarzalności charakterystyk ograniczników przepięć oraz obliczenia współczynników poprawkowych koniecznych dla przeliczania wyników pomiarów prądu upływowego na temperaturę odniesienia. Procedura taka jest konieczna podczas porównywania wyników badań wykonywanych w różnych warunkach zewnętrznych. Dla temperatur od 263 K do 323 K należy liczyć się nawet z dwukrotną zmianą prądu upływowego w stosunku do przyjętej temperatury odniesienia wynoszącej 293 K.
The article discusses the results of measurements of current - voltage characteristics in terms of leakage current metal oxide surge arresters (ZnO) for temperatures in the range 263 K - 373 K. The study was performed in order to determine the repeatability characteristics of surge arresters and calculate the correction factors necessary for translating the results of measurements of the leakage current at the reference temperature. Such a procedure is necessary when comparing the results of tests performed in different external conditions. Effect of temperature on the leakage current is observed only for voltages not exceeding maximum continuous operating voltage. When performing measurements at temperatures ranging from 263 K to 323 K can be expected even with the double change of leakage current in relation to the reference temperature of 20oC. In addition, arresters with higher continuos operating voltage have a lower effect of temperature on the leakage current. There is a significant influence of the chemical composition of the varistor on the level of leakage current, and thus the value of the correction factor kT.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 39; 51-54
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of metal oxide surge arresters as elements of overvoltage protection systems
Modelowanie ograniczników przepięć z tlenków metali jako elementów systemów ochrony przepięciowej
Autorzy:
Furgał, J.
Dau, S. K.
Powiązania:
https://bibliotekanauki.pl/articles/320307.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
ograniczniki przepięć
symulacje komputerowe
surge arresters
mathematical modelling
Opis:
Metal oxide surge arresters are used for protection of high and low voltage electric devices against overvoltages. Mathematical models of surge arresters should properly represent current-voltage dependencies of varistors during influence overvoltages. From among numerous models created so for two versions of a selected model were used for computer simulations of current-voltage dependences of surge arresters. Parameters of elements of the selected model can be calculated by use of data published in the catalogues. Current-voltage dependencies of the surge arrester designed for electric power systems of 110 kV for different current stroke were modelled. The results of computer simulations were compared with the experimental data.
Ograniczniki przepięć są powszechnie stosowane do ochrony przepięciowej urządzeń elektrycznych wysokiego i niskiego napięcia. Modele matematyczne ograniczników powinny właściwie odzwierciedlać charakterystyki napięciowo-prądowe warystorów podczas oddziaływania przepięć. Spośród wielu modeli opracowanych dotychczas do symulacji komputerowych zależności napięciowo-prądowych wybrano jeden model ograniczników. Parametry elementów modelu wyznaczono przy wykorzystaniu danych katalogowych. Modelowano zależności napięciowo-prądowe dla różnych udarów prądowych ogranicznika przepięć stosowanego w układach elektroenergetycznych 110 kV. Obliczenia porównano z wynikami badań.
Źródło:
Elektrotechnika i Elektronika; 2008, 27, 1; 14-19
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of surge arresters models to overvoltages studies in electrical networks
Porównanie modeli ograniczników przepięć wykorzystywanych do analiz przepięciowych w systemach elektroenergetycznych
Autorzy:
Oramus, P.
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/267829.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
frequency-dependent models
GIS substation
lightning overvoltages
surge arresters
modele zmienno-częstotliwościowe ograniczników przepięć
rozdzielnice izolowane gazem (GIS)
przepięcia atmosferyczne
Opis:
Overvoltages occurring in electrical power networks are caused by changes of power network operation conditions (e.g. faults, lightning strikes or switching operations). In order to limitation of overvoltages, Metal Oxide Surge Arresters (MOSA) are installed in electrical networks. To analyze and determine overvoltages values in electrical power systems, dedicated simulations are necessary. This paper deals with frequencydependent surge arresters models utilized for overvoltages studies by means of EMTP/ATP simulation software. Various surge arresters models have been presented in this article. In order to compare simulation results, each surge arrester model has been used to perform lightning overvoltages simulations occurring in the analyzed electrical network. Simulation results show influence of surge arrester model type on obtained simulation results and estimated overvoltages observed in electrical network.
Przepięcia występujące w sieciach elektroenergetycznych powodowane są przez zmianę warunków pracy obwodu – m. in. przez zwarcia, wyładowania atmosferyczne do linii przesyłowych, czy też operacje łączeniowe. W celu ograniczenia przepięć w sieciach elektroenergetycznych stosowane są ograniczniki przepięć z tlenków metali. Aby określić wartości przepięć podczas trwania stanów nieustalonych, konieczne jest przeprowadzanie symulacji komputerowych. Niniejszy artykuł zawiera opis zmienno-częstotliwościowych modeli ograniczników przepięć, wykorzystywanych do symulacji komputerowych. W celu porównania poszczególnych model, opracowano ich schematy zastępcze w programie EMTP/ATP, a także wykonano z ich użyciem analizę przepięć atmosferycznych w sieci elektroenergetycznej.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 36; 145-148
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problematyka opracowania systemu ochrony sieci trakcyjnej przed przepięciami w oparciu o warystorowe ograniczniki przepięć
Development issues of catenary surge protection system based on a varistor surge arresters
Autorzy:
Białoń, A.
Zawadka, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/314408.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
sieć kolejowa
trakcja elektryczna
sieć trakcyjna
ograniczniki przepięć
warystor
ochrona przed przepięciami
railway network
electric traction
contact system
overvoltage limiter
varistor
overvoltage protection
Opis:
W artykule opisano zagadnienia związane z ochroną sieci trakcyjnej 3 kV DC przed przepięciami pochodzącymi od wyładowań atmosferycznych i procesów komutacyjnych. Zwięźle uwidoczniono problemy wynikające z istnienia tych przepięć, ich źródeł i przedstawiono aktualny stan ochrony przed tymi przepięciami. Omówiono koncepcję ochrony przed przepięciami z wykorzystaniem warystorowych ograniczników przepięć. Zaprezentowano wyniki badań nowego systemu ochrony przed przepięciami.
The article presents issue of determinating an optimal distance between varistors located on 3 kV DC catenary. Line attenuation as a function of distance has been determined during preliminary tests for the following measurement configurations: catenary network unloaded (open), catenary network charged by a value of resistance close to the value of wave impedance of the catenary network test section, catenary network charged by a low voltage varistor. The results allowed to estimate the optimal distance between the varistors and they were verified on the catenary network on Żmigród Test Ring using a surge generator with an amplitude of about 15 kV and varistors designed to work in rail-way enviroment. The methodology and results of these studies were presented and analyzed in this paper.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 6; 43-46, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spektroskopia impedancyjna w badaniach właściwości ograniczników przepięć niskiego napięcia poddanych działaniu impulsowych narażeń energetycznych
Impedence spectroscopy in investigations of low voltage surge arresters exposed on impulse energetic stresses
Autorzy:
Zydroń, P.
Bonk, M.
Fuśnik, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/267491.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ograniczniki przepięć
warystory tlenkowe
spektroskopia impedancyjna
diagnostyka
surge arresters
metal-oxide varistors
impedance spectroscopy
diagnostics
Opis:
Ograniczniki przepięć stosowane do ochrony instalacji i urządzeń elektrycznych są obecnie wytwarzane głównie na bazie warystorów tlenkowych ZnO. Każde przepięcie powoduje powstanie narażenia energetycznego, które w pewnym stopniu degraduje wewnętrzną strukturę warystora. W efekcie zmienia to jego właściwości oraz wskutek kumulowania się efektów starzeniowych prowadzi do skrócenia czasu życia. Artykuł przedstawia metodę i wyniki badań niskonapięciowych ograniczników przepięć z warystorami tlenkowymi, poddawanych działaniu standaryzowanych impulsowych narażeń energetycznych. W badaniach zastosowano układ pomiarowy umożliwiający rejestrację szerokopasmowych charakterystyk niskosygnałowej impedancji warystorów. W oparciu o te dane analizowano zmiany wybranych parametrów elektrycznych, wywołane efektami starzeniowymi.
Surge arresters used for protection of electrical installations and devices are currently manufactured mainly from ZnO varistors. Each overvoltage causes energetic stress, which degrades the internal structure of the varistor. As a result, it changes its properties, and by cumulative effects of aging processes reduces the lifetime. The paper presents the method and results of the investigations of low voltage ZnO surge arresters stressed by standardized current pulses 8/20 ms repeated in 5 experimental cycles. In laboratory studies a FRA measuring system was used to record broadband impedance characteristics of varistors. Based on impedance spectroscopy data changes in selected electrical parameters of varistors due to the cumulative effects of energetic stresses were analyzed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 46; 115-118
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zawartości włókna szklanego na właściwości elektryczne i mechaniczne poliamidowej osłony izolacyjnej ograniczników przepięć
Influence of the glass fiber content on electrical and mechanical properties of the polyamide insulating housing of the surge arresters
Autorzy:
Kogut, K.
Kasprzyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/159050.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
ogranicznik przepięć
wyładowanie powierzchniowe
ładunek powierzchniowy
ładunek przestrzenny
poliamidy
włókno szklane
prąd termicznie stymulowany
Opis:
W pracy przedstawiono mechanizmy wyładowań powierzchniowych na próbkach wykonanych z poliamidu oraz poliamidu z dodatkiem włókna szklanego, wykorzystywanych jako osłony izolacyjne beziskiernikowych ograniczników przepięć. Ograniczniki podczas prób napięciem impulsowym ulegały uszkodzeniu na skutek przeskoków powierzchniowych. Przeskoki powierzchniowe prowadzą do rozwarstwienia pomiędzy izolacyjną osłoną a stosem warystorów. W celu określenia wpływu materiału wykonanego na osłonę, na rozwój wyładowania, wykonano pomiary napięć przeskoków. Określono rolę ładunku pomierzchniowego w rozwoju wyładowania. Aby wykazać znaczenie ładunku przestrzennego w materiale stosowanym na osłony wykonano pomiary prądów termicznie stymulowanych (TSD). Na podstawie danych podanych przez producentów porównano wytrzymałość mechaniczną materiałów.
In this paper the mechanisms of the surface discharges on the samples of the polyamide and polyamide with glass fiber used as insulating housing of the surge arrester, were introduced. Damage of the surge arresters while high impulse voltage tests, are results of the surface discharges. The surface flashovers lead to stratification between insulating housing and varistors pile. To define the impact of the insulating material of the surge arrester housing on development of the surface discharge, flashover voltage were measured. The role of a surface charge in the development of surface discharge was shown. To define the role of the interfacial space charge in the material for insulating housing, thermal stimulated current (TSD) were measured. On the basis of the parameters given by the manufacturer the mechanical strength of the samples were compared.
Źródło:
Prace Instytutu Elektrotechniki; 2009, 241; 113-124
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Matlab software for determination of the energy absorption capacity of modern surge arresters depending on the number of absorbed current pulses
Zastosowanie oprogramowania Matlab do szybkiego wyznaczania zdolności absorbcji energii udarów prądowych przez nowoczesne ograniczniki przepięć w zależności od liczby udarów
Autorzy:
Szafraniak, B.
Bonk, M.
Smugala, D.
Fuśnik, Ł.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/267248.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
metal-oxide varistors
degradation processes
surge stresses
diagnostics
warystory tlenkowe
procesy degradacyjne
narażenia udarowe
diagnostyka
Opis:
Metal-oxide surge arresters (MOSA) used in power networks for limiting of the electrical surges are exposed for many stresses in operating conditions. Electrical and thermal factors cause degradation of arresters internal structure being result of absorbed energy and aging processes cumulative effects. As result, changes of its nominal parameters are observed and significant reduction of the devices lifetime is noticed as well. For MOSA diagnosis and endurance estimation, large number of tests is usually needed. It results in great volume of gathered measurement results. Number of collected data as the effect of experiments, needs effective methods for fast extraction of the specific parameters evaluated in post-processing procedures. In this paper Matlab script for improvement and accelerating of analysis process is presented. Developed software, allowed determination of the surge energies dissipated in arresters, valuation the accumulated energy, as well as averages of voltage, current and surges energy.
Aparatura ochronna używana w sieciach energetycznych jest narażona podczas pracy na dużą liczbę udarów napięciowych. Naprężenia elektryczne i termiczne, którym poddawane są ograniczniki przepięć, powodują degradację ich struktury. Związane z tym zmiany wartości parametrów, są skutkiem procesów starzeniowych, będących rezultatem absorbowanej energii. Oszacowanie trwałości ograniczników może odbywać się przez określenie zmian ich stanu w efekcie dużej liczby udarów, jakim w warunkach laboratoryjnych poddane zostały egzemplarze testowe. W wyniku badań uzyskuje się dużą liczbę danych pomiarowych. W artykule przedstawiono oprogramowanie służące skróceniu czasu wykonania analiz oraz umożliwiające szybkie wyznaczenie sumarycznej energii udarów oraz całkowitej energii absorbowanej przez ograniczniki. Dzięki temu możliwe jest oszacowanie zmiany zdolności ogranicznika do absorbcji energii w zależności od liczby, częstości aplikowania i sumarycznej wartości zaabsorbowanej energii wszystkich udarów.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 60; 117-120
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-17 z 17

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies