Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ionization" wg kryterium: Wszystkie pola


Tytuł:
Initial recombination of ions in ionization chambers filled with hydrocarbon gases
Autorzy:
Gryziński, M.
Golnik, N.
Zielczyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/148268.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
initial recombination
ionization chambers
Opis:
Data on the initial recombination of ions are needed for designing recombination chambers, used in mixed radiation dosimetry in order to obtain information about radiation quality. Nevertheless, experimental data for pressurized gases are scarce, whereas reliable theoretical models are absent. The paper provides experimental data on the initial recombination in hydrocarbon gases (methane, ethane and propane) depending on gas pressure up to 1.8 MPa. The data were derived from the measurements of saturation curves of a tissue equivalent recombination chamber of an REM-2 type, in reference radiation fields of 137Cs and 239Pu-Be sources. Ion recombination due to volume recombination and back diffusion of ions was subtracted from the measured values of ion collection efficiency. The values of gas parameters needed for the subtraction procedure were determined by measurements of saturation curves of the chamber at several dose rates for each gas pressure. The important practical rule resulting from the experiments is that in the first approximation the initial recombination does not depend on the kind of the hydrocarbon gas but only on its density in the chamber.
Źródło:
Nukleonika; 2007, 52, 1; 7-12
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of diamond powder in the ionization process
Autorzy:
Brzecka, P.
Janaszczyk, A.
Chuchracki, M.
Mitura, K.
Powiązania:
https://bibliotekanauki.pl/articles/284028.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
diamond powder
ionization
allergic reaction
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 86
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact Ionization Process in Deep Submicron MOSFET
Autorzy:
Speransky, D.
Borzdov, A.
Borzdov, V.
Powiązania:
https://bibliotekanauki.pl/articles/398035.pdf
Data publikacji:
2012
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
MOSFET
metoda Monte Carlo
jonizacja zderzeniowa
energia progowa
Monte Carlo
impact ionization
threshold energy
Opis:
Within the framework of Keldysh impact ionization model the calculation of effective threshold energy for silicon MOSFET with 100 nm channel length by means of ensemble Monte-Carlo simulation is performed. The possibility of impact ionization rate treatment with one-parameter Keldysh model in pre-breakdown and breakdown transistor operation mode using calculated effective threshold energy value is proposed.
Źródło:
International Journal of Microelectronics and Computer Science; 2012, 3, 1; 21-24
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precise measurement of chlorine isotopes by thermal ionization mass spectrometry
Autorzy:
Neskovic, O.
Veljkoviç, M.
Velickoviç, S.
Deriç, A.
Miljeviç, N.
Golobocanin, D.
Powiązania:
https://bibliotekanauki.pl/articles/147003.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
chlorine isotopes
mass spectrometry
thermal ionization
Opis:
A procedure for the determination of chlorine isotopic ratios by positive thermal ionization mass spectrometry of the Cs2Cl+ ion has been investigated. The chlorine isotopic composition in CsCl spectroscopically pure has been measured with a precision of 0.034. The chlorine composition in sea water samples has also been determined.
Źródło:
Nukleonika; 2002, 47,suppl.1; 85-87
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensated ionization chamber for (n,α) reaction measurements at a spallation neutron source
Autorzy:
Andrzejewski, J.
Yu, M.
Gledenov, M.
Korejwo, A.
Sobczak, K.
Szałański, P.
Powiązania:
https://bibliotekanauki.pl/articles/146570.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ionization chamber
pulsed neutron source
Opis:
The new spallation neutron facility n_TOF (neutron time-of-flight) at CERN opens wide possibilities in measurements of neutron induced reaction cross sections. The facility with its excellent energy resolution of neutrons, low repetition rate and most important – with a very high instantaneous luminosity, makes up an extra challenge for experimenters faced by doing measurements at a high peak intensity spallation source. Our proposition is directed to the use of a compensated ionization chamber for the (n, alpha) reaction cross section measurements we plan to carry out in a wide range of neutron energy. First experience gained with using such a kind of detector at ORELA (the Oak Ridge Electron Linear Accelerator) neutron source (ORNL) was very optimistic.
Źródło:
Nukleonika; 2007, 52, 2; 51-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Test measurements of thoron concentration using two ionization chambers AlphaGUARD vs. radon monitor RAD7
Autorzy:
Kochowska, E.
Kozak, K.
Kozłowska, B.
Mazur, J.
Dorda, J.
Powiązania:
https://bibliotekanauki.pl/articles/148134.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
thoron
thoron concentration
ionization chamber
Opis:
The experiment aiming at testing the possibility of using AlphaGUARD monitors based on an ionization chamber for thoron measurements is presented. A single AlphaGUARD monitor working in the flow mode was applied to measure thoron concentration in the radon-free atmosphere. The sensitivity (correction factors) of the monitor to thoron was estimated by comparison with a RAD7 portable detector (Durridge Company), based on spectrometric analysis, in the thoron, radon-free atmosphere in a calibration chamber. This depends on the applied flow rate and changes from 8% for the flow rate of 0.3 dm3/min to 36% for 1 dm3/min. It was also revealed that the sensitivity of the monitor to thoron in the diffusion mode is equal to ca. 5% and may be neglected. The method involving two Alpha-GUARD monitors working in two different modes (diffusion and flow) at the same time may be used to evaluate radon and thoron concentration in the natural environmental conditions where usually both isotopes appear together. In this method thoron concentration is estimated as the difference of results obtained from two AlphaGUARD monitors multiplied by the correction factor corresponding to the applied flow rate. The devices based on spectrometric analysis, e.g. RAD7 seem to be a better tool for thoron measurements in the environmental conditions.
Źródło:
Nukleonika; 2009, 54, 3; 189-192
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resonance Ionization Spectroscopy and its Application
Autorzy:
Kluge, H.-J.
Powiązania:
https://bibliotekanauki.pl/articles/1931508.pdf
Data publikacji:
1994-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
32.80.Fb
Opis:
Resonance ionization spectroscopy and its combination with mass spectrometry offer very high sensitivity and selectivity. The application of several variants of resonance ionization mass spectroscopy to the study of nuclear ground state properties and trace analysis of radioactive isotopes in the environment is discussed as well as the inverse process, i.e. the laser induced recombination, of bare heavy ions stored at relativistic energies in storage rings.
Źródło:
Acta Physica Polonica A; 1994, 86, 1; 159-171
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of the ionization process inside a miniature glow-discharge micropump
Autorzy:
Grzebyk, T.
Górecka-Drzazga, A.
Powiązania:
https://bibliotekanauki.pl/articles/200204.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ion-sorption micropump
MEMS-type micropump
gas discharge
ionization
mikropompa jonowo-sorpcyjna
mikropompa typu MEMS
wyładowanie gazu
jonizacja
Opis:
The article presents a detailed characterization of the ionization process taking place inside a miniature MEMS-type ion-sorption vacuum pump, based on the Penning pump architecture. Influence of a variety of parameters on the discharge current has been investigated. These include: magnetic field, type of material used for the electrodes as well as horizontal and vertical dimensions of the micropump. It was found that the micropump works efficiently as long as the magnetic field is higher than 0.3 T, and the pumping cell’s dimensions exceed 1x1x1 mm3. Best results have been obtained for copper and aluminum cathodes and low resistivity silicon anodes.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 2; 173-178
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ionization processes in grain weight under strong electric field
Autorzy:
Bereka, O.
Usenko, S.
Powiązania:
https://bibliotekanauki.pl/articles/410716.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
silne pole elektryczne
procesy jonizacji
ozon
waga ziaren
procesy przyjazne środowisku
strong electric field
ionization processes
ozone
grain weight
environmentally friendly processing of grain
Opis:
The results of studies depending on the relative intensity characteristics of ionization processes in grain weight of the electric field of high intensity, humidity and established empirically analytical dependence.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2012, 1, 1; 17-20
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Desorption/ionization on silicon for small molecules: a promising alternative to MALDI TOF.
Autorzy:
Kraj, Agnieszka
Dylag, Tomasz
Gorecka-Drzazga, Anna
Bargiel, Sylwester
Dziuban, Jan
Silberring, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/1043452.pdf
Data publikacji:
2003
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
proteomics
porous silicon
catecholamines
peptides
DIOS
mass spectrometry
desorption/ionization
MALDI TOF
Opis:
A method has been developed for laser desorption/ionization of catecholamines from porous silicon. This methodology is particularly attractive for analysis of small molecules. MALDI TOF mass spectrometry, although a very sensitive technique, utilizes matrices that need to be mixed with the sample prior to their analysis. Each matrix produces its own background, particularly in the low-molecular mass region. Therefore, detection and identification of molecules below 400 Da can be difficult. Desorption/ionization of samples deposited on porous silicon does not require addition of a matrix, thus, spectra in the low-molecular mass region can be clearly readable. Here, we describe a method for the analysis of catecholamines. While MALDI TOF is superior for proteomics/peptidomics, desorption/ionization from porous silicon can extend the operating range of a mass spectrometer for studies on metabolomics (small organic molecules and their metabolites, such as chemical neurotransmitters, prostaglandins, steroids, etc.).
Źródło:
Acta Biochimica Polonica; 2003, 50, 3; 783-787
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanomateriały w spektrometrii mas z laserową desorpcją/jonizacją wspomaganą powierzchnią
Nanomaterials applied in surface-assisted laser desorption/ionization mass spectrometry
Autorzy:
Arendowski, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/2200434.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
laserowa desorpcja/jonizacja
metody bezmatrycowe
nanocząstki
SALDI
spektrometria mas
laser desorption/ionization
mass spectrometry
matrix-free methods
nanoparticles
Opis:
Laser desorption/ionization (LDI) is one of the most popular ionization techniques currently used in mass spectrometry (MS). This technique is most commonly used in a variant of matrix-assisted laser desorption/ionization (MALDI), which uses low molecular weight organic acid mixed with the sample to support the ionization process. However, this approach has some shortcomings such as: high chemical background in the spectral region below m/z 700 making it difficult to analyze compounds giving signals in this spectral region, inhomogeneous co-crystallization of analyte and matrix leading to the formation of so-called "sweet spots", i.e. inhomogeneous distribution of analyte in the crystallizing matrix. For these reasons, increasing research attention is focused on the possibilities offered by the use of matrix-free systems based on nanostructures in laser methods, which are referred to as surface-assisted laser desorption/ionization (SALDI). The use of nanostructures in LDI MS has made it possible to analyze low molecular compounds, often at very low concentrations, without the presence of matrix-derived chemical background, contributing to more applications of the LDI MS method. This work describes what the SALDI technique is and reviews the nanomaterials used in different variations of the approach. Among the described materials used in SALDI there are nanomaterials based on carbon and silicon, including the DIOS method, as well as techniques based on nanoparticles of gold, silver, platinum and titanium oxide. For each method, application examples are given for the detection of different classes of chemical compounds, often also in complex biological mixtures.
Źródło:
Wiadomości Chemiczne; 2022, 76, 9-10; 735--754
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dezynfekcja powietrza promieniami UV i promieniową jonizacją katalityczną w instalacjach wentylacyjnych
Disinfecting air with UV and radial catalytic ionization in ventilation systems
Autorzy:
Małecka, I.
Borowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/407530.pdf
Data publikacji:
2011
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
instalacja wentylacyjna
dezynfekcja
promienie UV
promieniowa jonizacja katalityczna
ventilation system
disinfection
UV radiation
catalytic radial ionization
Opis:
Stężenia mikrobiologiczne urządzeń technologicznych i instalacyjnych m.in. wentylacyjno-klimatyzacyjnych mają wpływ na rozwój bakterii chorobotwórczych. Dezynfekcja mikrobiologiczna układów instalacji wentylacyjnej wykonywana poprzez użycie środków chemicznych, pary wodnej jest możliwa tylko w przypadku przerwy w realizacji produkcji. W sytuacji gdy względy technologiczne wymagają ciągłej dezynfekcji powietrza wentylacyjnego, to należy stosować dezynfekcję powietrza w instalacjach wentylacyjnych promieniami UV i z wykorzystaniem promieniowej jonizacji katalitycznej. W artykule zaprezentowano także uwarunkowania oraz wady i zalety dezynfekcji powietrza promieniami UV i promieniowej jonizacji katalitycznej.
Microbiological concentration in process and installation systems including ventilation and air conditioning systems contributes to growth of pathogenic bacteria. Microbiological disinfection of ventilation systems using chemical agents and steam is possible only when manufacturing is stopped. When process considerations require continuous disinfection of ventilation air, UV radiation and catalytic radial ionization should be employed to disinfect air. The articles also presents conditions, advantages and disadvantages of disinfecting air with UV radiation and catalytic radial ionization.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2011, 3; 25-30
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of the gas ionization signal for combustion process diagnostics in the cylinder of a spark ignition engine
Autorzy:
Fiedkiewicz, Ł.
Pielecha, I.
Wisłocki, K.
Powiązania:
https://bibliotekanauki.pl/articles/133059.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
gas engine
ionization sensor
pressure sensor
engine control
lean fuel mixture
silnik gazowy
czujnik jonizacji
czujnik ciśnienia
sterowanie silnika
Opis:
The running diagnostics of the combustion process in an internal combustion engine is essential for increasing its efficiency and to improving its performance indicators. The modern diagnostics of this process no longer concerns only measurements of fast-changing thermodynamic variables, but also measurements of other parameters allowing for its evaluation. The use of electrical or optical methods in diagnostics enables the evaluation of local process parameters, such as occurrence of the flame and its temperature distribution. Actually, there are some new methods under investigation which are proposed for this kind of diagnostic. This article focuses on demonstrating the potential for using an electric signal from the gas ionization to estimate the maximum combustion pressure in a cylinder of an SI engine. This is a comparative analysis of the gas ionization current signal in the cylinder and the fast-changing pressure at fixed operating points of a 4-stroke natural gas powered engine. The study was carried out on a one-cylinder 4-stroke SI engine equipped with a cylinder pressure recording system and monitoring of the cylinder ionization current using appropriate measuring systems. The influence of engine operating conditions on the ability to determine cylinder pressure based on the ionization current signal was analyzed. This impact assessment was analyzed statistically and a strong correlation was found between the analyzed signals. The obtained results point in the potential direction of development of this type of measuring system.
Źródło:
Combustion Engines; 2017, 56, 4; 196-200
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CI Calculations of the Ground State Ionization Potential and Electron Affinity of Aluminum
Autorzy:
Hussein, Adnan
Powiązania:
https://bibliotekanauki.pl/articles/1401866.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
31.15.V-
Opis:
Nonrelativistic configuration interaction study for Al⁺, Al and Al¯ are presented, included calculations of ionization potential and electron affinity of the ²P° ground state of Al. CI calculations up to double, triple and quadrupole excitations for Al⁺, Al and Al¯, respectively, where neon fixed core is considered. Appropriate Slater type basis functions were developed suitable to recover both of core-valence and core-core correlation effect. The relativistic effect on both ionization potential and electron affinity are taken into account at the relativistic Hartree-Fock level. The calculated electron affinity is 432.811 meV which is in excellent agreement with experimental value of Sheer et al. 432.83(5) meV, whereas the calculated ionization potential is 5985.764 meV, the latter is in perfect agreement with experimental value of 5985.768 meV.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 268-273
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surface Ionization of Radioactive Nuclides - Numerical Simulations
Autorzy:
Turek, M.
Powiązania:
https://bibliotekanauki.pl/articles/1400445.pdf
Data publikacji:
2013-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.77.Ka
07.05.Tp
34.35.+a
Opis:
The Monte Carlo method based model of the ionization in the hot cavity taking into account radioactive decay of nuclides is presented. The code upgraded compared to the previous version enables calculation of the ion source ionization efficiency not only for different geometries and temperatures of the ionizer, extraction voltages etc. but also gives opportunity of setting different values of the nuclide half-life and its sticking time, which may be considered as the main factor determining the time that a particle spends in the ion source. The results of calculations are presented together with the discussion of the radioactive decay on the ion source performance.
Źródło:
Acta Physica Polonica A; 2013, 123, 5; 847-850
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The characteristic of ionization signal in cylinder of combustion engine the SI
Charakterystyka sygnału jonizacji w cylindrze silnika spalinowego ZI
Autorzy:
Filipek, P.
Kamiński, T.
Powiązania:
https://bibliotekanauki.pl/articles/244098.pdf
Data publikacji:
2008
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
silniki spalinowe
prąd jonizacji
wtrysk benzyny
świeca zapłonowa
procesy spalania
combustion engines
ionization current
fuel injection
spark plug
combustion processes
Opis:
During work, in cylinder of combustion engine the sparkle ignition get chemical and thermal processes. They initiate the production the ionized gas in combustion chamber. Ion sensing is one of the cheapest and most simple methods for monitoring the combustion event in a spark ignited engine. The characteristic of ionization signal in cylinder of engine the SI contains many helpful information in controlling the work of engine. This contributes to reducing emission offumes and lengthens the viability of catalyst. For spark ignited engines the spark plug is used as sensor together with some measurement electronics added to the ignition system. It is a relatively cheap method for combustion monitoring and other sensors can be replaced. The use of ion sensing in modern EMS is restricted to knock and misfire detection but engine developers start to see a need for other combustion information, such as air-fuel ratio, torque, combustion stability and location ofpeak pressure. The ionization current has a characteristic shape. One proposal divides the ion current in three parts, the ignition phase, the flame front phase and the post-flame phase. Despite the considerable uncertainty the ionization signal, characterizes very short time of reaction on change of parameters combustion in relation to traditional lambda probe.
Podczas pracy w cylindrze silnika spalinowego o zapłonie iskrowym zachodzą zarówno procesy chemiczne, jak i termiczne. Inicjują one wytwarzanie zjonizowanego gazu w komorze spalania. Pomiar jonizacji jest jednym z najprostszych i najtańszych metod monitorowania procesów zachodzącychw silnikach o zapłonie iskrowym. Przebieg charakterystyki sygnału jonizacji w cylindrze silnika ZI zawiera wiele informacji pomocnych w sterowaniu pracą silnika. Przyczynia się to między innymi do zmniejszania ilości emisji spalin oraz wydłużania żywotności katalizatora. Dla silników ZI czujnikiem jonizacji jest świeca zapłonowa wraz z dodanym do systemu zapłonowego układem rejestrującym. Jest to stosunkowo tania metoda mogąca zastąpić inne czujniki. Użycie metody wykrywania jonów w nowoczesnych systemach EMS ogranicza wykrywanie braku zapłonu i spalania stukowego, ale producenci samochodowi zwracają uwagę na inne informacje o spalaniu takie jak X, moment obrotowy, stabilność spalania i lokalizacja szczytowej wartości ciśnienia w cylindrze. Prąd jonizacji ma charakterystyczną krzywą. Jedna z propozycji dzieli prąd na trzy części, fazę zapłonu, fazę frontu płomienia i fazę popłomienną. Sygnał jonizacji mimo znacznej niepewności, charakteryzuje się bardzo krótkim czasem reakcji na zmianę parametrów spalania w stosunku do tradycyjnej sondy lambda.
Źródło:
Journal of KONES; 2008, 15, 2; 61-67
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection and sequencing of new cyclic peptides from linseed by electrospray ionization mass spectrometry.
Autorzy:
Stefanowicz, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1044059.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
cyclolinopeptides
mass spectrometry
Opis:
Extract of Linum usitatissimum seeds was analyzed by ESI-MS and ESI-MS/MS. The analysis confirms the presence of previously reported cyclolinopeptides: CLA (c(Pro-Pro-Phe-Phe-Leu-Ile-Ile-Leu-Val) and CLB (c(Pro-Pro-Phe-Phe-Val-Ile-Met-Ile-Leu)). Cyclolinopeptides CLD and CLE, which contain methionine oxide, were detected in small quantities only. These peptides likely result from the oxidation of their precursors, not reported previously: CLD' (c(Pro-Phe-Phe-Trp-Ile-Met-Leu-Leu)) and CLE' (c(Pro-Leu-Phe-Ile-Met-Leu-Val-Phe)), present at higher concentrations in unoxidized extract. Two new cyclic octapeptides: CLF (c(Pro-Phe-Phe-Trp-Val-Met-Leu-Met)) and CLG (c(Pro-Phe-Phe-Trp-Ile-Met-Leu-Met)) were detected and their sequences were proposed on the basis of CID experiments and similarity with those of CLD'.
Źródło:
Acta Biochimica Polonica; 2001, 48, 4; 1125-1129
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Ionization in a Spherical Surface Ionizer
Autorzy:
Turek, M.
Powiązania:
https://bibliotekanauki.pl/articles/1504138.pdf
Data publikacji:
2011-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.77.Ka
07.05.Tp
34.35.+a
Opis:
A Monte Carlo method-based model of a hot cavity surface ion source with a spherically shaped ionizer is presented. A numerical code enables studies of ion source efficiency as a function of an extraction voltage, geometry of the ionizer and its temperature, the size of extraction aperture and many other factors. The calculation results for a variety of mentioned parameters are presented. A novel configuration of surface ion source is proposed and discussed - the efficiency of the source with an almost spherically shaped ionizer could be much higher than that of currently used constructions of ion sources.
Źródło:
Acta Physica Polonica A; 2011, 120, 1; 188-191
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stabilizacja wybranych parametrów strumienia termoelektronów w gazowych źródłach jonów
Stabilization of selected parameters electron beam ion sources
Autorzy:
Kuś, D.
Sikora, J.
Powiązania:
https://bibliotekanauki.pl/articles/408179.pdf
Data publikacji:
2012
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
próżnia
jonizacja
prąd termoemisji elektronowej
energia elektronów
stabilizator
próżniomierz jonizacyjny
spektrometr mas
vacuum
ionization
thermionic electron emission current
electron energy
stabilizer
ionization gauge
mass spectrometer
Opis:
W pracy przedstawiono przegląd rozwiązań stosowanych w próżniomierzach jonizacyjnych i spektrometrach mas wykorzystujących strumień termoelektronów do jonizacji materii w postaci gazowej, w szczególności przykłady konstrukcji źródeł jonów oraz układów polaryzacji ich elektrod. Na podstawie wyników przeprowadzonej analizy zaproponowano nowy sposób detekcji prądu termoemisji elektronowej dla układów stabilizacji natężenia strumienia i energii elektronów.
This paper presents an overview of the vacuum measurement instruments using electron - impact gas ion sources, especially examples of the ion sources and biasing systems. Based on the analysis results a new thermionic emission current detection method to implementation in stabilizer of ionizing beam intensity and electron energy has been proposed.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2012, 4a; 15-17
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ionization Energies of RE Ions in wide Bandgap Sulphides
Autorzy:
Świątek, K.
Godlewskl, M.
Powiązania:
https://bibliotekanauki.pl/articles/1879958.pdf
Data publikacji:
1991-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
71.55.Gs
78.55.Et
Opis:
An analysis of rare earth (RE) energy level positions in wide bandgap sulphides is presented. It is shown that the Jörgensen's refined spin-pairing energy theory (RESPET) predicts correctly the photo-ionization (PI) energy of Sm in ZnS.
Źródło:
Acta Physica Polonica A; 1991, 79, 2-3; 247-250
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ionization of Short-Lived Isotopes in Spherical Hot Cavities
Autorzy:
Turek, M.
Powiązania:
https://bibliotekanauki.pl/articles/1402238.pdf
Data publikacji:
2015-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.77.Ka
07.05.Tp
34.35.+a
Opis:
The numerical model of ionization of short-lived nuclides in spherical hot cavities is presented. Two different cavity configurations are considered: one of them (the hemispherical one) resembles that known from already existing ion sources while the other (closer to the full sphere) could be more efficient for short-lived isotopes. Changes of ionization efficiency with the half-life period as well as with the particle average sticking time are presented and discussed. Influence of the extraction opening radius on ionization efficiency is also under investigation.
Źródło:
Acta Physica Polonica A; 2015, 128, 5; 935-938
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field Ionization of Shallow Acceptors
Autorzy:
Dargys, A.
Žurauskas, S.
Žurauskienė, N.
Powiązania:
https://bibliotekanauki.pl/articles/1861465.pdf
Data publikacji:
1993-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
71.70.Ej
73.20.Hb
79.70.+q
Opis:
Experimental studies on hole tunneling from the substitutional boron impurity into degenerate valence band of silicon single crystals are presented. The results are interpreted within the framework of acceptor ground state quartet splitting into the Kramers doublet due to presence of random strains and electric field in the lattice.
Źródło:
Acta Physica Polonica A; 1993, 84, 4; 629-632
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of MALDI-TOF MS for dermatophyte identification
Autorzy:
Dabrowska, I.
Dworecka-Kaszak, B.
Powiązania:
https://bibliotekanauki.pl/articles/6182.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
application
MALDI-TOF MS zob.matrix-assisted laser desorption-ionization time-of-flight mass spectrometry
matrix-assisted laser desorption-ionization time-of-flight mass spectrometry
dermatophyte
identification
detection
fungi
mammal
skin disease
hair
nail
Opis:
Dermatophytes are keratinolytic fungi responsible for a wide variety of diseases of the skin, nails and hair of mammals. Their identification is often complicated, labor-intensive and time consuming due to the high degree of intra-species morphological similarity, and also requires scientific knowledge and practice. The aim of this study was to demonstrate that MALDI-TOF MS technique may be a faster and more sophisticated method useful for the identification of dermatophytes and mycoses in general.
Źródło:
Annals of Parasitology; 2014, 60, 3
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Enhanced microdialysis of neuropeptides.
Autorzy:
Pettersson, Andreas
Markides, Karin
Bergquist, Jonas
Powiązania:
https://bibliotekanauki.pl/articles/1044057.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
neuropeptides
electrospray ionization orthogonal time-of-flight mass spectrometry
enhanced microdialysis
Opis:
An enhanced microdialysis method for neuropeptides is described and some preliminary results of this novel approach are presented. The enhancement is achieved by adding a vehicle (solid support) to the perfusion fluid in order to increase the diffusion coefficient across the membrane and efficiently transport the analytes towards the detector. The microdialysis samples are desalted and then analyzed on an electrospray ionization orthogonal time-of-flight mass spectrometer. The preliminary results show major increase in signal when comparing this new approach of microdialysis with ordinary microdialysis.
Źródło:
Acta Biochimica Polonica; 2001, 48, 4; 1117-1119
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polarization Dependence of Microwave "ionization" of Excited Hydrogen Atoms
Autorzy:
Koch, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/1968532.pdf
Data publikacji:
1998-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
32.80.Rm
05.45.+b
42.50.Hz
Opis:
After a brief review of the ionization of excited hydrogen atoms by a linearly polarized field, we discuss experimental results for the polarization dependence of this process. Experiments at ω/2π = 9.904 GHz used two different ranges of principal quantum number n$\text{}_{0}$ between 29 and 98. At low scaled frequencies, Ω ≲ 0.1, ionization data for certain narrow ranges of n$\text{}_{0}$ exhibit striking sensitivity to fields with elliptical polarization not too far from circular polarization. Classical calculations reproduce this behavior and show it to be the result of 2ω driving terms that appear when the Hamiltonian is transformed to a frame rotating at ω. It shows how higher-dimensional dynamics can influence the ionization and be used to control it when the polarization departs from linear or circular polarization. At higher scaled frequencies, 0.6 ≲ Ω$\text{}_{0}$ ≲ 1.4, near the onset of ionization circularly and elliptically polarized data show surprising similarities with linearly polarized data in a parameter regime where the ionization dynamics is dominated by the influence of the pendulumlike resonance zone centered at scaled frequency n$\text{}_{0}^{3}$ω ≡ Ω$\text{}_{0}$ = 1. The stabilizing influence of this zone can be understood classically, but nonclassical stability associated with quantal separatrix states at its edge is a semiclassical effect.
Źródło:
Acta Physica Polonica A; 1998, 93, 1; 105-133
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies