Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ionization" wg kryterium: Wszystkie pola


Tytuł:
Initial recombination of ions in ionization chambers filled with hydrocarbon gases
Autorzy:
Gryziński, M.
Golnik, N.
Zielczyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/148268.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
initial recombination
ionization chambers
Opis:
Data on the initial recombination of ions are needed for designing recombination chambers, used in mixed radiation dosimetry in order to obtain information about radiation quality. Nevertheless, experimental data for pressurized gases are scarce, whereas reliable theoretical models are absent. The paper provides experimental data on the initial recombination in hydrocarbon gases (methane, ethane and propane) depending on gas pressure up to 1.8 MPa. The data were derived from the measurements of saturation curves of a tissue equivalent recombination chamber of an REM-2 type, in reference radiation fields of 137Cs and 239Pu-Be sources. Ion recombination due to volume recombination and back diffusion of ions was subtracted from the measured values of ion collection efficiency. The values of gas parameters needed for the subtraction procedure were determined by measurements of saturation curves of the chamber at several dose rates for each gas pressure. The important practical rule resulting from the experiments is that in the first approximation the initial recombination does not depend on the kind of the hydrocarbon gas but only on its density in the chamber.
Źródło:
Nukleonika; 2007, 52, 1; 7-12
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of diamond powder in the ionization process
Autorzy:
Brzecka, P.
Janaszczyk, A.
Chuchracki, M.
Mitura, K.
Powiązania:
https://bibliotekanauki.pl/articles/284028.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
diamond powder
ionization
allergic reaction
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 86
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact Ionization Process in Deep Submicron MOSFET
Autorzy:
Speransky, D.
Borzdov, A.
Borzdov, V.
Powiązania:
https://bibliotekanauki.pl/articles/398035.pdf
Data publikacji:
2012
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
MOSFET
metoda Monte Carlo
jonizacja zderzeniowa
energia progowa
Monte Carlo
impact ionization
threshold energy
Opis:
Within the framework of Keldysh impact ionization model the calculation of effective threshold energy for silicon MOSFET with 100 nm channel length by means of ensemble Monte-Carlo simulation is performed. The possibility of impact ionization rate treatment with one-parameter Keldysh model in pre-breakdown and breakdown transistor operation mode using calculated effective threshold energy value is proposed.
Źródło:
International Journal of Microelectronics and Computer Science; 2012, 3, 1; 21-24
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precise measurement of chlorine isotopes by thermal ionization mass spectrometry
Autorzy:
Neskovic, O.
Veljkoviç, M.
Velickoviç, S.
Deriç, A.
Miljeviç, N.
Golobocanin, D.
Powiązania:
https://bibliotekanauki.pl/articles/147003.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
chlorine isotopes
mass spectrometry
thermal ionization
Opis:
A procedure for the determination of chlorine isotopic ratios by positive thermal ionization mass spectrometry of the Cs2Cl+ ion has been investigated. The chlorine isotopic composition in CsCl spectroscopically pure has been measured with a precision of 0.034. The chlorine composition in sea water samples has also been determined.
Źródło:
Nukleonika; 2002, 47,suppl.1; 85-87
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensated ionization chamber for (n,α) reaction measurements at a spallation neutron source
Autorzy:
Andrzejewski, J.
Yu, M.
Gledenov, M.
Korejwo, A.
Sobczak, K.
Szałański, P.
Powiązania:
https://bibliotekanauki.pl/articles/146570.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ionization chamber
pulsed neutron source
Opis:
The new spallation neutron facility n_TOF (neutron time-of-flight) at CERN opens wide possibilities in measurements of neutron induced reaction cross sections. The facility with its excellent energy resolution of neutrons, low repetition rate and most important – with a very high instantaneous luminosity, makes up an extra challenge for experimenters faced by doing measurements at a high peak intensity spallation source. Our proposition is directed to the use of a compensated ionization chamber for the (n, alpha) reaction cross section measurements we plan to carry out in a wide range of neutron energy. First experience gained with using such a kind of detector at ORELA (the Oak Ridge Electron Linear Accelerator) neutron source (ORNL) was very optimistic.
Źródło:
Nukleonika; 2007, 52, 2; 51-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Test measurements of thoron concentration using two ionization chambers AlphaGUARD vs. radon monitor RAD7
Autorzy:
Kochowska, E.
Kozak, K.
Kozłowska, B.
Mazur, J.
Dorda, J.
Powiązania:
https://bibliotekanauki.pl/articles/148134.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
thoron
thoron concentration
ionization chamber
Opis:
The experiment aiming at testing the possibility of using AlphaGUARD monitors based on an ionization chamber for thoron measurements is presented. A single AlphaGUARD monitor working in the flow mode was applied to measure thoron concentration in the radon-free atmosphere. The sensitivity (correction factors) of the monitor to thoron was estimated by comparison with a RAD7 portable detector (Durridge Company), based on spectrometric analysis, in the thoron, radon-free atmosphere in a calibration chamber. This depends on the applied flow rate and changes from 8% for the flow rate of 0.3 dm3/min to 36% for 1 dm3/min. It was also revealed that the sensitivity of the monitor to thoron in the diffusion mode is equal to ca. 5% and may be neglected. The method involving two Alpha-GUARD monitors working in two different modes (diffusion and flow) at the same time may be used to evaluate radon and thoron concentration in the natural environmental conditions where usually both isotopes appear together. In this method thoron concentration is estimated as the difference of results obtained from two AlphaGUARD monitors multiplied by the correction factor corresponding to the applied flow rate. The devices based on spectrometric analysis, e.g. RAD7 seem to be a better tool for thoron measurements in the environmental conditions.
Źródło:
Nukleonika; 2009, 54, 3; 189-192
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resonance Ionization Spectroscopy and its Application
Autorzy:
Kluge, H.-J.
Powiązania:
https://bibliotekanauki.pl/articles/1931508.pdf
Data publikacji:
1994-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
32.80.Fb
Opis:
Resonance ionization spectroscopy and its combination with mass spectrometry offer very high sensitivity and selectivity. The application of several variants of resonance ionization mass spectroscopy to the study of nuclear ground state properties and trace analysis of radioactive isotopes in the environment is discussed as well as the inverse process, i.e. the laser induced recombination, of bare heavy ions stored at relativistic energies in storage rings.
Źródło:
Acta Physica Polonica A; 1994, 86, 1; 159-171
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of the ionization process inside a miniature glow-discharge micropump
Autorzy:
Grzebyk, T.
Górecka-Drzazga, A.
Powiązania:
https://bibliotekanauki.pl/articles/200204.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ion-sorption micropump
MEMS-type micropump
gas discharge
ionization
mikropompa jonowo-sorpcyjna
mikropompa typu MEMS
wyładowanie gazu
jonizacja
Opis:
The article presents a detailed characterization of the ionization process taking place inside a miniature MEMS-type ion-sorption vacuum pump, based on the Penning pump architecture. Influence of a variety of parameters on the discharge current has been investigated. These include: magnetic field, type of material used for the electrodes as well as horizontal and vertical dimensions of the micropump. It was found that the micropump works efficiently as long as the magnetic field is higher than 0.3 T, and the pumping cell’s dimensions exceed 1x1x1 mm3. Best results have been obtained for copper and aluminum cathodes and low resistivity silicon anodes.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 2; 173-178
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ionization processes in grain weight under strong electric field
Autorzy:
Bereka, O.
Usenko, S.
Powiązania:
https://bibliotekanauki.pl/articles/410716.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
silne pole elektryczne
procesy jonizacji
ozon
waga ziaren
procesy przyjazne środowisku
strong electric field
ionization processes
ozone
grain weight
environmentally friendly processing of grain
Opis:
The results of studies depending on the relative intensity characteristics of ionization processes in grain weight of the electric field of high intensity, humidity and established empirically analytical dependence.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2012, 1, 1; 17-20
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Desorption/ionization on silicon for small molecules: a promising alternative to MALDI TOF.
Autorzy:
Kraj, Agnieszka
Dylag, Tomasz
Gorecka-Drzazga, Anna
Bargiel, Sylwester
Dziuban, Jan
Silberring, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/1043452.pdf
Data publikacji:
2003
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
proteomics
porous silicon
catecholamines
peptides
DIOS
mass spectrometry
desorption/ionization
MALDI TOF
Opis:
A method has been developed for laser desorption/ionization of catecholamines from porous silicon. This methodology is particularly attractive for analysis of small molecules. MALDI TOF mass spectrometry, although a very sensitive technique, utilizes matrices that need to be mixed with the sample prior to their analysis. Each matrix produces its own background, particularly in the low-molecular mass region. Therefore, detection and identification of molecules below 400 Da can be difficult. Desorption/ionization of samples deposited on porous silicon does not require addition of a matrix, thus, spectra in the low-molecular mass region can be clearly readable. Here, we describe a method for the analysis of catecholamines. While MALDI TOF is superior for proteomics/peptidomics, desorption/ionization from porous silicon can extend the operating range of a mass spectrometer for studies on metabolomics (small organic molecules and their metabolites, such as chemical neurotransmitters, prostaglandins, steroids, etc.).
Źródło:
Acta Biochimica Polonica; 2003, 50, 3; 783-787
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies