Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Inverter" wg kryterium: Wszystkie pola


Tytuł:
Extended T-type inverter
Autorzy:
Rąbkowski, J.
Kopacz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1193496.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
T-type inverter
boost converter
silicon carbide
Opis:
This paper presents a new concept for a power electronic converter – the extended T-type (eT) inverter, which is a combination of a three-phase inverter and a three-level direct current (dc)/dc converter. The novel converter shows better performance than a comparable system composed of two converters: a T-type inverter and a boost converter. At first, the three-level dc/dc converter is able to boost the input voltage but also affects the neutral point potential. The operation principles of the eT inverter are explained and a simulation study of the SiC-based 6 kVA system is presented in this paper. Presented results show a serious reduction of the DC-link capacitors and the input inductor. Furthermore, suitable SiC power semiconductor devices are selected and power losses are estimated using Saber software in reference to a comparative T-type inverter. According to the simulations, the 50 kHz/6 kVA inverter feed from the low voltage (250 V) shows <2.5% of power losses in the suggested SiC metal oxide–semiconductor field-effect transistors (MOSFETs) and Schottky diodes. Finally, a 6 kVA laboratory model was designed, built and tested. Conducted measurements show that despite low capacitance (2 × 30 μF/450 V), the neutral point potential is balanced, and the observed efficiency of the inverter is around 96%.
Źródło:
Power Electronics and Drives; 2018, 3, 38; 55-64
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-phase soft-switching inverter with coupled inductors, experimental results
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/200045.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant inverter
ZVS inverter
Opis:
This paper presents experimental results of the three-phase soft-switching inverter with coupled inductors that verify the control method influence on efficiency improvement. Different kinds of control methods were tested on the 6 kW experimental inverter. A short discussion on a few design methods of the resonant tank elements was made. Experimental results confirm that the advanced control algorithm and the proposed new design method of the resonant tank elements significantly increase the efficiency of this resonant inverter.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 535-540
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency control of inverter fed induction motor drives
Autorzy:
Shaban, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/376136.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
induction motor
torque-speed characteristic
inverter
Opis:
Induction motor losses at partial loads can be significantly reduced by operating an adjustable frequency drive at the optimum slip which yields maximum efficiency. The present investigation quantifies the potential improvement in induction motor efficiency for both standard and energy efficient motors operating on a six-step voltage-source inverter supply. The analysis employs a comprehensive model of the induction motor which incorporates the frequency - dependent nature of the motor parameters and effects of stray load loss. Efficiency contours are plotted on a torque- speed plane for constant volts/hertz operation and for optimum slip frequency control plotted as a contour map.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 72; 291-295
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Z-source converter in photovoltaic grid-connected transformer-less inverter
Autorzy:
Farhangi, B.
Farhangi, S.
Powiązania:
https://bibliotekanauki.pl/articles/262715.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
photovoltaic power conditioner (PV PCU)
gird-connected systems
Z-source inverter
inverter
Opis:
In PV grid connected power conditioners, usually both stepping-up the PV array voltage, and stepping-down the dc bus voltage for injection of a sinusoidal current to the grid is required. In this paper the design procedure of Z-source converter as a single phase PV grid connected transformer-less inverter is presented. The converter has one switch less than the conventional two stage power conditioner, which leads to reduction of cost. An optimum modulation pattern for the switches is proposed, and the low frequency ripple of the converter is modeled. The design of the converter is verified by simulation.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 41-45
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiphase Z-source inverter using maximum constant boost control
Autorzy:
Kouzou, A.
Abu-Rub, H.
Powiązania:
https://bibliotekanauki.pl/articles/229291.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Z-source inverter
multiphase inverter
five phase machine
shoot-through
boost factor
duty cycle
Opis:
This paper deals with the impedance source (Z-source) multiphase inverter, where the maximum constant boost control method is studied and analyzed in the general case of number of phases. On the other side the impact of the modulation index and the number of phases on the duty cycle shoot-through and on the gain of the output voltage ranges is presented. To validate advantages of the Z-source multiphase inverter, the proposed topology and the maximum constant boost control are implemented in simulation and in real time experimentation with Z-source five phase inverter. The output voltage is applied to two parallel loads, a five phase resistive load and a five phase induction machine.
Źródło:
Archives of Control Sciences; 2013, 23, 1; 107-126
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified Topology and Modulation Technique for Z-Source Neutral-Point Clamped Inverter
Autorzy:
Akbari, Ehsan
Zishan, Farhad
Powiązania:
https://bibliotekanauki.pl/articles/2175930.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
modulation
optimization
multilevel inverter
MZS-NPC
Opis:
The impedance network makes it possible to increase and decrease the voltage, which is not available in normal inverters (voltage and current sources).This paper presents a modified topology and modulation technique for a three-phase Modified Z-Source Neutral-Point Clamped (MZS-NPC) inverter. A modulation scheme for the proposed topology is designed based on maximum gain control method to achieve the maximum voltage gain by simple implementation and balancing the neutral point voltage of the dc link. In order to supply the desired voltage to the critical load in an islanded micro-grid, a closed-loop ac voltage controller is realized in fuel cell or photovoltaic applications based on the proposed inverter. The ability to reinforce and validity of topology operations and modulation techniques has been demonstrated by simulation. It should be noted that the simulations are implemented in MATLAB / Simulink software.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 210--226
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adjusting output impedance using a PI controller to improve the stability of a single-phase inverter under weak grid
Autorzy:
Jiao, J.
Nelms, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/136224.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
grid impedance
inverter output impedance
LC filter
PI controller
single-phase inverter
Opis:
Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 50-57
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of space vector modulation strategy on hybrid (Si-SiC) inverter losses
Autorzy:
Bonisławski, M.
Hołub, M.
Powiązania:
https://bibliotekanauki.pl/articles/140592.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik hybrydowy
elektronika energetyczna
urządzenie z szeroką przerwą energetyczną
SVPWM
DPWM
power electronic inverter
SiC diodes
hybrid inverter
wide band gap devices
Opis:
This work summarizes efficiency measurement results of a full bridge, 3 phase inverter composed of state-of-the-art Si IGBT transistors and Si or SiC diodes. Different (symmetrical and discontinuous) space vector modulation strategies were chosen in order to examine their influence (together with modulation frequency) on inverter losses. Induction machine was used as load, different load points were examined. Results clearly show, that proper modulation strategy, minimizing the switching losses of semiconductor switches, can increase the overall output efficiency at about 1% in case of both silicon and hybrid constructions. The drawback of DPWM approach is connected with the decreased quality of inverter output current. Hybrid technology can also improve the output efficiency at about 1% when compared to traditional constructions, but only in case of elevated switching frequencies. At low frequencies (below 10 kHz) modern semiconductor offer comparable results at much lower device costs.
Źródło:
Archives of Electrical Engineering; 2012, 61, 1; 69-75
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental results of parallel connected inverters feeding medium voltage transformer
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/377860.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical transformer
line side inverter
inrush currents
inverter parallel operation
Opis:
Development of medium voltage, high power ship electrical installations on board of special purpose vessels, has led to use of grid side inverters along with step-up grid transformers. In this paper there is presented theoretical background and experimental results of two inverters in parallel connection feeding one 0,4/15 kV transformer.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 90; 359-368
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of operation of class E ZVS resonant inverter
Autorzy:
Szychta, E.
Powiązania:
https://bibliotekanauki.pl/articles/262645.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
class E ZVS resonant
inverter
output capacitance
MOSFET transistor
zero voltage switching
Opis:
The article discusses class E zero-voltage-switching resonant inverter (ZVS). The resonant circuit of the inverter is subject to mathematical analysis using the method of state variables with the aid of MATLAB software. Results of simulation testing, based on Simplorer software, of an inverter at the operating frequency of 100kHz are presented.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 57-67
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
Autorzy:
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201199.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronous machine
DC/AC inverter
DTC
flux and torque control
3-level DC/AC inverter
Opis:
This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 771-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part II
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114230.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 325-328
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Measurement and Analysis of Harmonics and Interharmonics in Output Waveforms of Frequency Inverter. Part I
Autorzy:
Bartman, J.
Powiązania:
https://bibliotekanauki.pl/articles/114413.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
interharmonics
inverter
power quality analyzer
measurements
Opis:
The paper discusses the measurement and analysis of the voltage and output power distortions of frequency inverter that supplies an induction motor. It covers basic information regarding frequency inverters and norms with definitions and descriptions of terms related to the measurement of harmonics and interharmonics. Moreover, it describes the problems that can occur while analyzing the signal when the inter-harmonics are present during the measurement. Exemplary results of measurements done with power quality analyzer in the laboratory have been presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 10; 322-324
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault Diagnosis of Sensors for T-type Three-Level Inverter-fed Dual Three-Phase Permanent Magnet Synchronous Motor Drives
Autorzy:
Wang, Xueqing
Wang, Zheng
Wang, Wei
Cheng, Ming
Powiązania:
https://bibliotekanauki.pl/articles/1193713.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fault diagnosis
sensor fault
T-type inverter
three-level inverter
dual
three-phase
PMSM
Opis:
To improve the reliability of motor system, this paper investigates the sensor fault diagnosis methods for T-type inverter-fed dual three-phase permanent magnet synchronous motor (PMSM) drives. Generally, a T-type three-level inverter-fed dual three-phase motor drive utilizes four phase-current sensors, two direct current (DC)-link voltage sensors and one speed sensor. A series of diagnostic methods have been comprehensively proposed for the three types of sensor faults. Both the sudden error change and gradual error change of sensor faults are considered. Firstly, the diagnosis of speed sensor fault was achieved by monitoring the error between the rotating speed of stator flux and the value from speed sensor. Secondly, the large high-frequency voltage ripple of voltage difference between the estimated voltage and the reference voltage was used to identify the voltage sensor faults, and the faulty voltage sensor was determined according to the deviation of voltage difference. Thirdly, the abnormal current amplitude on harmonic subspace was adopted to identify the current sensor faults, and the faulty current sensor was located by distinguishing the current trajectory on harmonic subspace. The experiments have been taken on a laboratory prototype to verify the effectiveness of the proposed fault diagnosis schemes.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 165-176
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Initial Excitation Issues of Synchronous Generator with VSI Inverter in Varying Rotational Speed Operation
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/2064987.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
synchronous generator
initial excitation
FOC control
voltage source inverter
synchronization
Opis:
Synchronous self-excited generators still are and probably will be the most popular 3-phase alternators installed in inland power stations so onboard of seagoing ships. Because of fuel savings and environmental restrictions Diesel, dual-fuel and gas propulsion engines for alternators of wide-range varying revolutions drives are increasingly used. There must be efficient way of creating 3-phase voltages of desired constant parameters ensured when generator produces variable amplitudes and frequencies of voltages because of changing rotational speed. As the control method modified field oriented control widely used with squirrel cage induction machines was chosen. This control method involves decoupling of currents and control voltages to flux and torque components and keeping them in optimal (orthogonal) condition. In order to obtain proper excitation and operation of such generator several factors have to be taken into account. Nonlinear dependence of voltage generated from rotational speed of self-excited synchronous generator is one of the factors that affects initial excitation process thus specific control method while generator startup. Theoretical background of synchronous generator excitation and voltage source inverter adopted FOC control method along with experimental results obtained in laboratory test bench of 5,5 kW generator and conclusions were presented.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 377--383
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of reducing switching losses in three-level NPC inverter
Autorzy:
Beniak, R.
Rogowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1193262.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reduction of switching losses
three-level NPC inverter
space vector modulation
Opis:
The aim of the paper is to present a concept of implementation of a space vector modulation (SVM) algorithm, which is used to create alternating current waveforms of changing amplitude and frequency in power inverters. The main goal of the method is to decrease the number of state changes in power transistors. It is realized by utilizing a prediction algorithm and sequences of transistors, which are not common in use. The method requires measurement of inverter output current flow. The prediction algorithm analyzes possible sequences of transistors’ states and choose those which offers smaller switch count. A decrease of about 20% was obtained for the cases tested. This paper presents simulation result for selected driving scenario. The described method decreases the number of state changes in power transistors and therefore it is a potentially good method to considerably decrease energy losses of multilevel inverter-powered drive.
Źródło:
Power Electronics and Drives; 2016, 1, 36/2; 55-63
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model trakcyjnego falownika napięciowego
The model of the voltage traction inverter
Autorzy:
Dominikowski, B.
Pacholski, K.
Woźniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/312485.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
falownik napięciowy
SVPWM
sieć trakcyjna
voltage inverter
traction line
Opis:
W artykule przedstawiono model falownika napięciowego typu DC/AC wykorzystywany w zmodernizowanych elektrycznych zespołach trakcyjnych (EZT). W przekształtniku tym wykorzystano metodę sterowania typu SVPWM (ang. Space Vector Pulse Width Modulation), która pozwala w sposób dokładny odwzorować na jego zaciskach wyjściowych przebiegi napięcia sinusoidalnie zmiennego. Obwód tego typu pracujący w sieci trakcyjnej generuje tętnienia wartości wejściowego prądu o częstotliwości sześciokrotnie wyższej niż częstotliwość jego napięcia wyjściowego. Na wejściu DC obwodu pośredniczącego falownika w elektrycznej trakcji szynowej monitoruje się wartość prądu obciążenia sieci jezdnej m.in. do wyznaczenia pobieranej energii elektrycznej pobranej przez zespół trakcyjny.
In the paper presented the model of the voltage inverter type DC/AC used in modernized electrical traction. In this inverter, the SVPWM (Space Vector Pulse Width Modulation) control method was used which allow to the accurately imitate the voltage sinusoidal variable waveforms on its output connectors. The circuit of this type working in overhead contact line generates pulsations of input-current at a frequency six times higher than the frequency of its output voltage. At the DC input of the inverter circuit in the electric traction rail, the load current of the mains network is monitored. to determine the electricity consumed by the traction unit.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 815-818, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multilevel inverter with optimal THD through the firefly algorithm
Autorzy:
El Mehdi Belkacem, R.
Benzid, R.
Bouguechal, N.
Powiązania:
https://bibliotekanauki.pl/articles/141495.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
firefly algorithm (FFA)
genetic algorithm (GA)
inverter
multilevel
optimized THD
Opis:
Reduction of the Total Harmonic Distortion (THD) in multilevel inverters requires resolution of complex nonlinear transcendental equations; in this paper we propose a combination of one of the best existing optimized hardware structures with the recent firefly algorithm, which was used to optimize the THD, through finding the best switching angles and guaranteeing the minimization of harmonics within a user defined bandwidth. The obtained THD through the simulation of the thirteen-level symmetric inverter has been reduced down to 5% (FFT of 60 harmonics). In order to validate the simulation results, a thirteen-level symmetric inverter prototype has been made, and practically experimented and tested with different loads. Consequently, the measured THD with resistive load was 4.7% on a bandwidth of 3 kHz. The main advantage of the achieved work is the reduction of the THD.
Źródło:
Archives of Electrical Engineering; 2017, 66, 1; 141-154
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of a single-phase inverter’s with voltage regulation
Autorzy:
Zaskalicky, P.
Zaskalicka, M.
Powiązania:
https://bibliotekanauki.pl/articles/2056350.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
model matematyczny
przekształtnik
regulacja napięcia
mathematical model
single-phase inverter
voltage regulation
Opis:
The paper deals with mathematical model of single-phase bridge inverters which outputs voltage is controlled by a pulse-width notching. The transistors in the inverter circuit are turned on and off so as to produce zero periods of equal length, for unipolar modulation, or negative voltage for bipolar modulation. The D.C. source is being a fixed level of voltage. Suppose the notching frequency to be constant for all frequency of the fundamental squarewaves and to be fixed on 500 Hz. The output inverter’s voltage is expressed by an analytical formula based on Fourier complex series. On the base of output voltage, the waveforms of the output currents are analytically calculated for different inverter’s loads.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2009, 83; 41-45
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Passive filter design for three-phase inverter interfacing in distributed generation
Autorzy:
Ahmed, K. H.
Finney, S. J.
Williams, B. W.
Powiązania:
https://bibliotekanauki.pl/articles/262578.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
DG
inverter
grid connected
filtering
damping
harmonics
Opis:
With the growing use of inverters in distributed generation, the problem of injected harmonics becomes critical. These harmonics require the connection of low pass filters between the inverter and the network. This paper presents a design method for the output LC filter in grid coupled applications in distributed generation systems. The design is according to the harmonics standards that determine the level of current harmonics injected into the grid network. Analytical expressions for the maximum inductor ripple current are derived. The filter capacitor design depends on the allowable level of switching components injected into the grid. Different passive filter damping techniques to suppress resonance affects are investigated and evaluated. Simulated results are included to verify the derived expressions.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 49-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Decomposition of EMI Noise into Common and Differential Modes in PWM Inverter Drive System
Autorzy:
Kempski, A.
Smoleński, R.
Powiązania:
https://bibliotekanauki.pl/articles/262576.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
electromagnetic compatibility
common mode
differential mode
PWM inverter drive system
Opis:
In this paper [20] an analytical approach to decomposition of total phase EMI noises through algebraic calculations and the Fourier transform has been presented. Separating conducted EMI noise into different, common and differential mode (CM and DM) HF current components is important for a proper spectral analysis and application of EMI mitigation techniques. The results of calculations have been compared to EMI currents measured on the motor side of the PWM drive system. The proposed approach can be useful in comparative analysis of the influence of inverter control algorithms on spectra of CM currents in a given drive system.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 53-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przemiennik częstotliwości jako nieliniowy odbiornik energii
Frequency inverter as a non-linear energy loads
Autorzy:
BARTMAN, Jacek
SOBCZYŃSKI, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/455461.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rzeszowski
Tematy:
nieliniowe odbiorniki energii przemiennik częstotliwości
non-linear energy loads
inverter
Opis:
Artykuł przedstawia zagadnienia związane z pracą nieliniowych odbiorników energii. Określa, jakie odbiorniki uznaje się za nieliniowe, a jakie za liniowe. Jako przykład odbiornika nieliniowego pokazany jest przemiennik częstotliwości pracujący w układzie napędowym z regulowaną prędkością obrotową. Pokazano odkształcenia napięcia i prądu wywołane pracą napędu.
The work presents the issues associated with the functioning of non-linear receivers of the energy. It determines, what receivers are being regarded non-linear and which too linear. As the example of the non-linear receiver a inverter working in the driving system with the adjusted rotation speed is shown. Showing voltage and current distortion caused by the drive.
Źródło:
Edukacja-Technika-Informatyka; 2016, 7, 4; 394-399
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the accuracy of inverter sync angle during the grids disturbances
Autorzy:
Jarzyna, Wojciech
Zieliński, Dariusz
Gopakumar, K.
Powiązania:
https://bibliotekanauki.pl/articles/221529.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inverter synchronization
synchronization angle
PLL
sync error
distributed grid
Opis:
The grid-tied inverter synchronizes with the network on the basis of the instantaneous voltage phase angle. This angle is computed by the so-called synchronization algorithms. During grid disturbances, it is estimated with a certain accuracy, which varies for different disturbances and depends on the choice of algorithm. The tests presented here determine how to make an optimal selection of the synchronization algorithm. The research methods used are modeling, simulation and analysis of the results obtained. One of the most important outcomes is the determination of the root-mean-square sync error and its dynamics denotation. The research conclusions should be of particular interest to designers of distributed energy systems with a large number of inverter energy sources.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 355-371
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel in-phase disposition SPWM pulse allocation strategy for cascaded H-bridge inverter
Autorzy:
Zhang, Y.
Xiong, J.
Kong, L.
Wang, X.
Powiązania:
https://bibliotekanauki.pl/articles/141155.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
in-phase disposition SPWM
Inverter
CHB
THD
Opis:
A novel in-phase disposition (IPD) SPWM pulse allocation strategy applied to a cascaded H-bridge (CHB) converter is presented in this paper. The reason causing the power of the CHB converter imbalance is analyzed according to the traditional structure, the conception of power imbalance degree is introduced and the principle of the novel in-phase disposition SPWM allocation strategy is deduced in detail. The new pulse allocation scheme can ensure the power balance in 3/4 cycles through interchanging the PWM pulse sequence of the different CHB cell, meanwhile it makes the full advantage of the IPD control strategy, lower the total harmonic distortion (THD) of line voltage compared to a carrier phase shifted (CPS) control strategy, which is verified by theoretical derivation. A seven-level cascaded inverter composed by three H-bridge cells is taken as the example. The simulation and experiment is performed. The results indicate the validity of the analysis and verify the effectiveness of the proposed SPWM allocation strategy.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 361--375
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CHB inverter with DC-link capacitor balancing and total harmonic minimization
Autorzy:
Armi, F.
Manai, L.
Besbes, M.
Powiązania:
https://bibliotekanauki.pl/articles/141332.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
CHB inverter
capacitor voltage balancing
switching angles
Newton Raphson
algorithm
SHE
THD
Opis:
A cascaded H-bridge (CHB) multilevel inverter generally requires several DC sources. An alternative option is to replace the separate DC source feeding an H-bridge cell with a capacitor, while maintaining the other H-bridge cell with a real DC voltage source. In this paper a 7-level cascaded H-bridge inverter with a single DC-source is presented. This paper focuses mainly to achieve effective capacitor voltage balancing and selective harmonic elimination (SHE) based on the Newton Raphson algorithm (N–R). It shows hope to reduce the voltage ripple of the capacitors, which leads to higher power conversion efficiency with equal power distribution, reduces the initial cost, and complexity hence it is apt for industrial applications. Simulation results support the proposed control technique.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 81-93
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Torque ripple calculation of a permanent magnet synchronous motor supplied by a three phase inverter with PWM
Autorzy:
Zaskalicky, P.
Powiązania:
https://bibliotekanauki.pl/articles/1372789.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
magnes trwały
przekształtnik
synchronous motor
permanent magnet
inverter
Opis:
A steady-state analysis of a permanent magnet synchronous motor drive with a voltage-source inverter is presented. The torque-speed profile required of the drive is a constant torque region from zero to the base speed and a constant power region above base speed. A Fourier series approach is used to predict the line current waveform. Assuming the output inverter's voltage is controlled by a pulse-width notching. Suppose the notching frequency to be constant for all frequency of the fundamental squarewave and to be fixed on 500 Hz. The permanent magnet synchronous motor model is obtained from its analogy to the fixed-excited synchronous motor. From the induced voltage and line current waveforms the electromagnetic torque ripple waveform is calculated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 88; 81-86
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalne sterowanie falownika przy jego pracy na sieć systemu energetycznego
Optimal inverter controling during its operation for power grid
Autorzy:
Mazur, D.
Powiązania:
https://bibliotekanauki.pl/articles/1369606.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
optymalne sterowanie
system energetyczny
optimal inverter
power grid
Opis:
The inverter circuit is supposed to operate for grid with low internal impedance (for fixed grid). The goal of the presented circuit is to provide the given current of the main harmonic to the grid. The grid can contain higher harmonics of the voltage, which due to the low impedance of the grid lines spreads to the voltage of the inverter output. Therefore we need to calculate the first (main) harmonic of this voltage and find such inverter controlling, that the main harmonic of the current flowing to the grid from the considered circuit would be in the given angle position to it and at the given value. The second important goal of the circuit is, as far as possible, to eliminate the voltage higher harmonics at the circuit output getting there from the grid. Obviously eliminating the ripples from voltage higher harmonics of the receiver is limited by the capabilities of the examined inverter circuit.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 2, 95; 25-30
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of reducing switch count in three-level NPC inverter – analysis in steady states
Autorzy:
Beniak, R.
Rogowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/1193464.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reduction of switch count
three-level NPC inverter
space vector modulation
Opis:
The proof of a concept for a new method of modulation has been presented which reduce switch count in a three-level neutral point clamped (3L-NPC) inverter. The method is an implementation of space vector modulation (SVM) by means of a prediction algorithm and sequences of transistors, which are not common in use. Those sequences make active use of clamping diodes of the inverter. The prediction algorithm analyzes possible sequences of transistors’ states and choose those which offers smaller switch count. Measurements of steady states were taken on prototype 3L-NPC.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 117-126
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Overview of Carrier-based Modulation Methods for Z-Source Inverter
Autorzy:
Roomi, Muhammad M.
Powiązania:
https://bibliotekanauki.pl/articles/1193846.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
AC/DC
power conversion
impedance source inverter
modulation methods
shoot through
phase opposition disposition
reference disposition
Opis:
Single-stage energy converters, in particular, the Z-Source Inverter (ZSI) or impedance source inverter, has gained significant attention in the recent years. ZSI ensures flexible energy conversions (dc–dc, dc–ac, ac–ac and ac–dc) because of its unique ability to boost the output voltage in typical renewable energy systems. The impedance network integrated between the energy source and the load contributes to the unique functionality of the ZSI. As substantial research has been conducted on the ZSI, this article provides a review on the operation of ZSI. The article initially examines the various topologies commonly adopted for the application of the ZSI. Subsequently, details of the various modulation methods that are commonly used to obtain the voltage boosting using ZSI are documented. Additionally, the phenomenon of neutral point formation, which is an important impediment to the adoption of multilevel ZSIs and the limitation of the modulation methods, is explained.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 15-31
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and simulation of novel stepped DC coupled quasi Z-Multilevel Inverter for single phase systems
Autorzy:
Meenakshi, T.
Suthanthira Vanitha, N.
Powiązania:
https://bibliotekanauki.pl/articles/140968.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multilevel inverter
shoot through
quasi Z-Source
modulation index
Opis:
This paper presents the modeling and simulation of a novel topology of quasi Z-Multilevel Inverter with stepped DC input. The proposed inverter incorporates a simple switching technique with reduced component count and is aimed at producing boosted multilevel output AC voltage. The inverter consists of two stages and the buck /boost operation is obtained by varying the shoot through period of the pulses obtained by maximum constant boost control with third harmonic injection. With all the advantages of the quasi Z-network, the proposed inverter eliminates the fly back diodes and capacitors present in a conventional Z-Multilevel Inverter. Further the stress on the devices is less which leads to reduction in component value and hence the cost. The novel stepped DC coupled Single Phase quasi Z-Multilevel Inverter is modeled and simulated in the MATLAB – SIMULINK environment and its performance is analyzed for varying input and switching conditions. The voltage and current waveforms across each stage of the inverter is analyzed and the results are presented for different levels of input.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 437-448
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ laboratoryjny z wektorową przetwornicą częstotliwości
The laboratory unit with vector frequency inverter
Autorzy:
Siostrzonek, T.
Mondzik, A.
Powiązania:
https://bibliotekanauki.pl/articles/320194.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wektorowa przetwornica częstotliwości
silnik indukcyjny klatkowy
vector frequency inverter
squirrel cage induction motor
Opis:
W artykule przedstawiono wykonane w Laboratorium Elektroniki Przemysłowej stanowisko dydaktyczne układu napędowego z silnikiem indukcyjnym klatkowym zasilanym z wektorowej przetwornicy częstotliwości. Stanowisko powstało dzięki współpracy Katedr Automatyki Napędu i Urządzeń Przemysłowych z firmą Moeller Electric. Studenci mają więc możliwość zapoznania się z urządzeniami stosowanymi w zakładach przemysłowych. Badanie układu zostało wykonane przez studentów Koła Naukowego Elektroniki Przemysłowej pod nadzorem autorów.
This paper presents the laboratory unit with squirrel cage induction motor supplied by vector frequency inverter. This unit was made thanks to cooperation the Department of Electrical Drive and Industrial Equipment with Moeller Electric. The students have the possibility to know the industrial devices. The research was made by students under the direction of authors.
Źródło:
Elektrotechnika i Elektronika; 2005, 24, 1; 100-105
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Falownik trójfazowy ze zmiennym algorytmem sterowania
Three-phase inverter with variable control algorithm
Autorzy:
Szerszeń, Grzegorz
Zygadło, Damian
Powiązania:
https://bibliotekanauki.pl/articles/2086188.pdf
Data publikacji:
2021
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
przemiennik częstotliwości
falownik
modulacja PWM
sterowanie skalarne
frequency converter
inverter
PWM modulation
scalar control
Opis:
Wpracyprzedstawionobudowę trójfazowegoprzemiennika częstotliwości zmożliwościąwyboru typu modulacji PWM oraz płynną zmianą częstotliwości sygnału modulowanego.Wpraktyczny sposób zrealizowano różne algorytmy sterowania falownikaw tymsamymukładzie sprzętowym zwykorzystaniemprocesora STMARMCortexM3. ZastosowaniemodulacjiTHIPWMpozwoliło zmniejszyć zawartośćharmonicznychw sygnalewyjściowymi efektywniewykorzystaćmożliwości źródła zasilania. Układ posiada możliwość wyboru jednego z dwóch algorytmów sterowania skalarnego, z opcją kompensacji wpływu rezystancji stojana na moment obrotowy wału silnika w początkowym zakresie charakterystyki sterowania liniowego przy stałym stosunku napięcia do częstotliwości. Badania potwierdziły, że najkorzystniejszym typem modulacji PWM w tym układzie jest modulacja jednobiegunowa dwubrzegowa.Wykorzystanie metodyTHIPWM, skutkowało zyskiem amplitudy podstawowej harmonicznej napięcia wyjściowego dla trójfazowego trybu pracy falownika względem metody SPWM. Uzyskano także odpowiednią precyzję kroku regulacji częstotliwości, a rezultaty badań potwierdziły funkcjonalność przemiennika.
The paper presents the construction of a three-phase frequency converter with the possibility of choosing the type of PWM modulation and a smooth change of the frequency of the modulated signal. In a practical way, various inverter control algorithms were implemented in the same hardware system using the STM ARM Cortex M3 processor. The use of THIPWM modulation allowed to reduce the harmonic content in the output signal and effectively use the possibilities of the power source. The system can choose one of two scalar control algorithms, with the option of compensation for the influence of the stator resistance on the motor shaft torque in the initial range of the linear control characteristic at a constant voltage to frequency ratio. The research confirmed that the most advantageous type of PWM in this system is unipolar double-edge modulation. The use of the THIPWM method resulted in a gain in the amplitude of the fundamental harmonic of the output voltage for the three-phase inverter operation mode compared to the SPWM method. The appropriate precision of the frequency control step was also obtained, and the test results confirmed the functionality of the converter.
Źródło:
Science, Technology and Innovation; 2021, 14, 3; 1--11
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A New 13-Level Switched-Capacitor Inverter with Reduced Device Count
Autorzy:
Jena, Kasinath
Panigrahi, Chinmoy Kumar
Gupta, Krishna Kumar
Powiązania:
https://bibliotekanauki.pl/articles/1956000.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
switched capacitor
voltage gain
component per level factor
cost function
Opis:
This paper proposed a new voltage-boosting 13-level switched-capacitor (SC) cost-effective inverter. The proposed topology comprises fourteen transistors, three capacitors and a single DC source to produce a 13-level staircase waveform. The capacitor voltage balancing problem is inherently solved by the series/parallel technique. Structural description, working principle, calculation of optimum values of capacitance and modulation scheme are briefly described. The comparative analyses with the existing SC multilevel inverter (MLI) in terms of voltage gain, blocking voltage, total standing voltage (TSV), component per level factor and cost function illustrate the merits of the proposed topology. Further, simulation and experimental results at different loading conditions verify the feasibility of the proposed topology.
Źródło:
Power Electronics and Drives; 2021, 6, 41; 26-41
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie falowników rezonansowych w przemyśle elektromaszynowym i wydobywczym
Application of resonance inverters in the electric machine and mining industry
Autorzy:
Marek, A.
Powiązania:
https://bibliotekanauki.pl/articles/186005.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
falownik L-LC
falownik rezonansowy
inverter L-LC
resonance inverter
Opis:
Celem artykułu jest przedstawienie i omówienie najczęściej stosowanych układów zasilających nagrzewnice indukcyjne, ich właściwości oraz porównanie ich z proponowanym rozwiązaniem w postaci falownika L-LC.
The paper aims at a presentation and a discussion on the mostly used power supply systems for induction heaters, their characteristics and comparison to a suggested system in the form of an inverter L-LC.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2009, R. 47, nr 2, 2; 17-22
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
Autorzy:
Turzyński, M.
Banach, P.
Murawski, P.
Pepliński, R.
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200484.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
resonant converters
ZVS three-phase inverter
current estimation
Opis:
Control of parallel quasi resonant dc link inverters (PQRDCLI) is usually based on dc link input inverter current. Instead of a direct measurement of this noise sensitive and fast changing current signal - its estimation with one step prediction may be considered. Estimation of an input inverter current is based on inverter output current measurements, applied in most of power electronics controlled ac drives. In this paper, the PQRDCLI fed induction motor (IM) with a predictive current estimation stabilizes resonant inverter output voltage slopes du/dt independently of load. By control of output voltage derivatives, reduction of overvoltage spikes and common mode motor currents is achieved. An analysis of the PQRDCLI control with a predictive current estimation strategy is verified by the Saber system simulation and experimental tests in a laboratory setup.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 757-762
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Static and dynamic MPP-tracking efficiency of PV-inverter using recorded irradiance
Autorzy:
Marańda, W.
Piotrowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/397987.pdf
Data publikacji:
2013
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
photovoltaics
MPP-tracking
PV inverter
tracking efficiency
fotowoltaika
śledzenie punktu mocy maksymalnej
przekształtnik PV
efektywność śledzenia
Opis:
This paper investigates the energy losses introduced by Maximum Power Point Tracking operation of photovoltaic (PV) inverter. In contrast to other studies, this evaluation has been done with the recorded real-life solar irradiance data applied to the simulation of the PV-generator and tracking algorithm. The true MPP output of photovoltaic generator has been calculated with electro-thermal model and the simulation has been carried out with 1 s time resolution. The efficiency results have been presented for both static and dynamic MPP-tracking investigated With basic and simplified Perturb&Observe algorithm with several tracking speed rates. In addition to the simulation, the inverter efficiency measurements for field- installed inverter have been presented.
Źródło:
International Journal of Microelectronics and Computer Science; 2013, 4, 4; 181-185
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of a permanent magnet motor with an inverter in a drive system of a car. Part 2
Autorzy:
Pawelski, Z.
Uszpolewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/245003.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
electrical machines
permanent magnet motor
inverter
electric drive control system
Opis:
The article presents a mathematical model of a permanent magnet motor, powered by a three-phase source of sinusoidal voltage, and a control method. Cooperation between numerical integration algorithms in the differential equation system of the motor and an inverter has been verified. The results of numerical simulations are presented in a graphic form. This article is an extension of the publication [12], in which a model of a drive system was proposed, consisting of: a battery, a supercapacitor and a method of controlling these energy sources during a driving cycle of a vehicle. For vector control, the mathematical model of a synchronous machine in the dq coordinate system is the most common one. The most important feature of this control method is the fact that the iq component of the rotor current vector determines the value of motor torque, and the component id – the value of magnetic flux. In the article, the emphasis is put on how inverters work. Their basic task is to generate such currents iabc or voltages uabc to obtain torque without ripples. It leads to development of different control concepts for achieving this goal, which are related to the modelling of magnetic fluxes in a stator and in an inverter.
Źródło:
Journal of KONES; 2018, 25, 4; 325-335
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania falownikowego napędu pompy wodnej z silnikiem indukcyjnym
The Test Inverter Drive the Water Pump with an Induction Motor
Autorzy:
Drabek, T.
Rusek, J.
Powiązania:
https://bibliotekanauki.pl/articles/1368614.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
diagnostyka
napęd falownikowy
induction motor
diagnostics
inverter driver
Opis:
This paper presents the results of tests of induction water pump drive with an inverter, installed In water supply station. The drive consists of induction motor with a power rating of 132kW, supplyed from voltage inverter with a power rating of 160kW, scalar controlled. The aim of the study was to determine the causes of repeated failures of the inverter. Subject of tests and diagnostic measurements was both, the inwerter and motor. Tests have shown the absence of any abnormalities in the operation of motor, including the lack of damage to the stator and rotor. Over the long-term measurements, there was no overvoltage in the feed of the inverter and the other sections of the drive circuit, that could cause damage of the drive. The conclusion of the tests is to identify the noise in control of the drive as the alleged source of the damage in its power module.
W artykule przedstawiono wyniki badań falownikowego napędu indukcyjnego pompy wodnej, zainstalowanego w wodociągach miejskich. Badany napęd składa się z głębinowego silnika indukcyjnego o mocy znamionowej 132kW, zasilonego z przemiennika częstotliwości o mocy znamionowej 160kW, sterowanego skalarnie. Celem badań było ustalenie przyczyn powtarzających się uszkodzeń części mocy przemiennika. Przedmiotem pomiarów kontrolnych i diagnostycznych był zarówno przemiennik jak i silnik. Badania wykazały brak jakichkolwiek nieprawidłowości w pracy silnika, w tym brak uszkodzeń stojana i wirnika. W ciągu pomiarów długookresowych stwierdzono również brak ew. przepięć na zasilaniu przemiennika i w innych punktach obwodu zasilania napędu, które mogłyby powodować uszkodzenia przemiennika. Konkluzją badań jest wskazanie zakłóceń sterowania samego przemiennika jak domniemanego źródła uszkodzeń jego części mocy.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 13-18
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ground leakage current caused by Common-Mode Voltage of PWM inverter
Prądy upływu doziemnego generowane napięciem wspólnym falownika MSI
Autorzy:
Szymański, Jerzy Ryszard
Żurek-Mortka, Marta
Powiązania:
https://bibliotekanauki.pl/articles/106701.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Technologiczno-Humanistyczny im. Kazimierza Pułaskiego w Radomiu
Tematy:
common-mode voltage
differential-mode voltage
PWM modulation
three-phase traction voltage inverter
two-level PWM inverter
dwupoziomowy falownik MSI
napięcie różnicowe
napięcie wspólne
modulacja MSI
trójfazowy trakcyjny falownik napięciowy
Opis:
In railway tractive vehicles, three-phase PWM (Pulse Width Modulation) inverters generate parasitic Differential-Mode Voltages (DMV) and Common-Mode Voltages (CMV). Parasitic voltages are a side effect of using the width modulation to shape the phase-to-phase inverter’s voltage. In this article, the authors present a mathematical description of the DM and CM voltages and carry out their spectral analysis. Based on the spectral harmonics analysis, the authors present a method for filtration of harmonics of DM and CM voltages aimed at limiting the capacitance parasitic currents: due to DM voltage – phase-to-phase parasitic current and CM voltage – ground parasitic currents. As the final result of the tests, almost complete elimination of leakage parasitic current form PE shock protection system was achieved.
W kolejowych pojazdach trakcyjnych trójfazowe falowniki MSI (Modulacja Szerokości Impulsów) wytwarzają pasożytnicze napięcia różnicowe (Differential Mode Voltage) i wspólne (Common Mode Voltage). Pasożytnicze napięcia są skutkiem ubocznym stosowania modulacji szerokościowej do kształtowania napięć międzyfazowych falownika. W artykule autorzy przedstawiają opis matematyczny napięć DM oraz CM i przeprowadzają ich analizę widmową. Na podstawie przeprowadzanej analizy autorzy przedstawiają metodę filtracji wybranych harmonicznych napięcia DM i CM dla ograniczania wytwarzanych przez nie prądów pasożytniczych: (DM) - międzyfazowych i (CM) – doziemnych. W wyniku badań osiągnięto prawie całkowitą eliminację pasożytniczego prądu upływu doziemnego z systemu ochrony przeciwporażeniowej PE.
Źródło:
Journal of Civil Engineering and Transport; 2019, 1, 1; 15-25
2658-1698
2658-2120
Pojawia się w:
Journal of Civil Engineering and Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation and experimental examinations of voltage inverter and synchronous generator synchronization system with the use of VisualDSP++ 5.0 environment
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/97413.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
synchronous generator
machine inverter
Radix–2 FFT
synchronization
DSP
real–time
Opis:
This study describes the operation of the programming algorithm used to synchronize the machine VSI inverter with the rotating synchronous generator. Presented algorithm which bases on the Radix–2 Fourier transform allows to synchronize the inverter with the machine with variable in wide range rotating speed. This study presents the results obtained with use of the simulation software and the auxiliary software created with the use of VisualDSP++ 5.0 development environment and exemplary results of an algorithm operation in the laboratory test stand.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 210-219
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on topology of a novel three-phase four-leg fault-tolerant NPC inverter
Autorzy:
Zhang, Baoge
Ping, Shanyan
Long, Yyi
Jiao, Yyuemin
Wu, Bboxiang
Powiązania:
https://bibliotekanauki.pl/articles/2086722.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault tolerant operation
midpoint potential equilibrium
NPC inverter
topology reconstruction
Opis:
Diode neutral point clamped (NPC) three-level converters have been widely used in recent years. Aiming at the problems of the high device failure rate and unstable neutral point potential of NPC three-level converters, an NPC three-level circuit with fourth bridge arm redundancy is proposed based on the traditional NPC three-level converter. The redundant fourth bridge arm is used to realize the function of stabilizing voltage when there is no fault and replacing the fault half-bridge arm to maintain the continuous operation of the converter when there is a fault. By analyzing the working principle of space vector pulse width modulation (SVPWM) and the power loss of the switch, it is of particular significance to the design and control of NPC three-level converters in the future. Matlab/Simulink verifies the feasibility of the fault-tolerant circuit structure.
Źródło:
Archives of Electrical Engineering; 2022, 71, 2; 489--506
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A closed-loop power controller model of series-resonant-inverter-fitted induction heating system
Autorzy:
Pal, P.
Roy, D.
Datta, A.
Sadhu, P. K.
Banerjee, A.
Powiązania:
https://bibliotekanauki.pl/articles/141721.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
induction heating
power controller
PID
series resonant inverter
MATLAB
Opis:
This paper presents a mathematical model of a power controller for a high-frequency induction heating system based on a modified half-bridge series resonant inverter. The output real power is precise over the heating coil, and this real power is processed as a feedback signal that contends a closed-loop topology with a proportional-integral-derivative controller. This technique enables both control of the closed-loop power and determination of the stability of the high-frequency inverter. Unlike the topologies of existing power controllers, the proposed topology enables direct control of the real power of the high-frequency inverter.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 827-841
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on low frequency ripple suppression technology of inverter based on model prediction
Autorzy:
Liu, Haiyang
Chen, Yiwen
Luo, Sixu
Jiang, Jiahui
Jian, Haojun
Powiązania:
https://bibliotekanauki.pl/articles/24202730.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
boost type
low frequency ripple suppression
model predictive control
single stage inverter
Opis:
The low frequency ripple of the input side current of the single-phase inverter will reduce the efficiency of the power generation system and affect the overall performance of the system. Aiming at this problem, this paper proposes a two-modal modulation method and its MPC multi-loop composite control strategy on the circuit topology of a single-stage boost inverter with a buffer unit. The control strategy achieves the balance of active power on both sides of AC and DC by controlling the stable average value of the buffer capacitor voltage, and provides a current reference for inductance current of the DC input side. At the same time, the MPC controller uses the minimum inductor current error as the cost function to control inductor current to track its reference to achieve low frequency ripple suppression of the input current. In principle, it is expounded that the inverter using the proposed control strategy has better low frequency ripple suppression effect than the multi-loop PI control strategy, and the conclusion is proved by the simulation data. Finally, an experimental device of a single-stage boost inverter using MPC multi-loop composite control strategy is designed and fabricated, and the experimental results show that the proposed research scheme has good low frequency ripple suppression effect and strong adaptability to different types of loads.
Źródło:
Archives of Electrical Engineering; 2023, 72, 2; 443--460
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensorless five-phase induction motor drive with third harmonic injection and inverter output filter
Autorzy:
Strankowski, P.
Guzinski, J.
Morawiec, M.
Lewicki, A.
Wilczynski, F.
Powiązania:
https://bibliotekanauki.pl/articles/200259.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sensorless control
five-phase induction motor
inverter output filter
multiscalar control
Opis:
The paper presents a sensorless control approach for a five-phase induction motor drive with third harmonic injection and inverter output filter. In the case of the third harmonic injection being utilised in the control, the physical machine has to be divided into two virtual machines that are controlled separately and independently. The control system structure is presented in conjunction with speed and rotor flux observers that are required for a speed sensorless implementation of the drive. The last section is dedicated to experimental results of the drive system in sensorless operation, and the uninterrupted drive operation for two open-phase faults.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 3; 437-445
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Particle swarm optimization of an iterative learning controller for the single-phase inverter with sinusoidal output voltage waveform
Autorzy:
Ufnalski, B.
Grzesiak, L. M.
Gałkowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/200271.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
iterative learning control
sine wave inverter
particle swarm optimization (PSO)
Opis:
This paper presents the application of a particle swarm optimization (PSO) to determine iterative learning control (ILC) law gains for an inverter with an LC output filter. Available analytical tuning methods derived for a given type of ILC law are not very straightforward if additional performance requirements of the closed-loop system have to be met. These requirements usually concern the dynamics of a response to a reference signal, the dynamics of a disturbance rejection, the immunity against expected level of system and measurement noise, the robustness to anticipated variations of parameters, etc. An evolutionary optimization approach based on the swarm intelligence is proposed here. It is shown that in the case of the ILC applied to the LC filter, a cost function based on mean squares can produce satisfactory tuning effects. The efficacy of the procedure is illustrated by performing the optimization for various noise levels and various requested dynamics.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 3; 649-660
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja wydajności urządzeń potrzeb własnych elektrowni cieplnych asynchronicznymi napędami falownikowymi średniego napięcia
Variable speed drives with frequency converters in thermal power plant auxiliaries
Autorzy:
Wawszczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/173004.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
elektrownia cieplna
napęd falownikowy
przemiennik
thermal power station
inverter drive
inverter
Opis:
Omówiono możliwości regulacji wydajności urządzeń potrzeb własnych elektrowni cieplnych napędzanych klatkowymi silnikami indukcyjnymi zasilanymi przemiennikami częstotliwości. Skupiono się głównie na napędach średnionapięciowych (6÷10 kV) dużej mocy. Przedstawiono aktualną ofertę przemienników czołowych światowych producentów. Oceniono możliwości wykorzystania tego typu napędów w dużych, nowoczesnych elektrowniach blokowych.
The paper introduces current potential of variable speed drives (VSD) intended for squirrel cage induction motors supplied by frequency converters in thermal power plant auxiliaries. The paper is mostly focused on medium-voltage (6-10 kV) and high-power drives. Current tender of leading world producers in this field has been presented. Possibility to apply this type of drives in large, modern block-power plants has been considered.
Źródło:
Archiwum Energetyki; 2013, 43, 1/2; 87-99
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel circuit topology of modified switched boost hybrid resonant inverter fitted induction heating equipment
Autorzy:
Bhattacharya, A.
Sit, K.
Sadhu, P. K.
Pal, N.
Powiązania:
https://bibliotekanauki.pl/articles/140770.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modified switched boost
high frequency
hybrid resonant inverter
induction heating
controllability
VSI and PSIM
Opis:
A novel circuit topology of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment is presented in this paper for efficient induction heating. Recently, induction heating technique is becoming very popular for both domestic and industrial purposes because of its high energy efficiency and controllability. Generally in induction heating, a high frequency alternating magnetic field is required to induce the eddy currents in the work piece. High frequency resonant inverters are incorporated in induction heating equipment which produce a high frequency alternating magnetic field surrounding the coil. Previously this high frequency alternating magnetic field was produced by voltage source inverters. But VSIs have several demerits. So, in this paper, a new scheme of modified switched boost high frequency hybrid resonant inverter fitted induction heating equipment has been depicted which enhances the energy efficiency and controllability and the same is validated by PSIM.
Źródło:
Archives of Electrical Engineering; 2016, 65, 4; 815-826
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new circuit topology using Z-source resonant inverter for high power contactless power transfer applications
Autorzy:
Ghosh, P. C.
Sadhu, P. K.
Ghosh, A.
Pal, N.
Powiązania:
https://bibliotekanauki.pl/articles/141006.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
contactless power transfer
mutual inductance
magnetic coupling coefficient
Z-source
resonant inverter
Opis:
In this study, a new circuit topology using a Z-source resonant inverter (ZSRI) for high power applications in large-air-gap contactless power transfer (CPT) systems, has been investigated. The main shortcoming of a large-air-gap CPT system is the poor power transfer efficiency due to low magnetic coupling. In order to minimize this shortcoming and to improve the overall performance of the system by boosting the power transfer capability, in this paper a CPT system with the newly developed circuit topology using high frequency Z-source resonant inverter has been proposed. Using the newly developed circuit topology for the CPT system, it has been observed that the overall performance of the system has been improved to a reasonable level with a purely sinusoidal resonant current flowing through the primary side. Therefore, no harmonics will be injected into the source. The proposed CPT system with an air gap of 16 cm and a misalignment of 3 cm has been simulated using the Maxwell finite element tool and Simplorer circuit simulation software for an output power of 2 kW.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 843-854
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
Autorzy:
Strankowski, Patryk
Guziński, Jarosław
Wilczyński, Filip
Morawiec, Marcin
Lewicki, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/1193764.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
five-phase induction motor
inverter output filter
open-phase fault detection
Opis:
The paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves the reliability of the complete drive system. A new idea of online open-phase fault detection is presented based on the frequency analysis of the estimated observer variables. The test setup, fault operation capabilities and an experimental verification of the proposed fault detection method are presented in the paper.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 189-200
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of fractional order PI controller using metaheuristics algorithms applied to multilevel inverter for grid connected PV
Autorzy:
Boucheriette, Wafa
Mechgoug, Raihane
Benguesmia, Hani
Powiązania:
https://bibliotekanauki.pl/articles/11541888.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
MLI inverter
fractional order PI
meta-heuristic
PSO
ABC
GWO
THD
metaheurystyka
falownik
układ regulacji
Opis:
Due to its multiple advantages in industrial and grid-connected applications, Multi-Level Inverters (MLIs) have increased in popularity in recent years. To improve the efficiency of a grid-connected PV system's integrated multi-level inverter fractional order PI (FOPI) controllers are used to describe the control process. The control system is made up of three control loops based on FOPI controllers: one for controlling the intermediate circuit voltage (Vdc) and the other two for controlling the direct and quadratic currents (Id, Iq) supplied by the multilevel inverter. The proposed controller parameters (Kp, KI, λ) must be selected in order to increase the efficiency of the multi-level inverter while decreasing the total harmonic distortion (THD) of the output current of the inverter as well as voltage. For this we used three meta-heuristic algorithms (PSO, ABC, GWO). The performance of the three controllers PSO-FOPI, ABC-FOPI and GWO-FOPI controller is compared. The findings showed that GWO-FOPI performs better than the other PSO-FOPI and ABC-FOPI in accuracy and total harmonic distortion THD term. The simulation will be conducted using Matlab/Simulink.
Źródło:
Diagnostyka; 2023, 24, 3; art. no. 2023311
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model predictive direct power control of energy storage quasi-Z-source grid-connected inverter
Autorzy:
Tang, Min'an
Yang, Shangmei
Zhang, Kaiyue
Wang, Qianqian
Liu, Chenggang
Dong, Xuewang
Powiązania:
https://bibliotekanauki.pl/articles/2042769.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
quasi Z-Source
inverter
energy storage
power control
model predictive
space vector
Opis:
In order to overcome the shortcoming of large switching losses caused by variable switching frequency appears in the conventional finite control set model predictive control (FCS-MPC) algorithm, a model predictive direct power control (MP-DPC) for an energy storage quasi-Z-source inverter (ES-qZSI) is proposed. Firstly, the power prediction model of the ES-qZSI is established based on the instantaneous power theory. Then the average voltage vector in the coordinate system is optimized by the power cost function. Finally, the average voltage vector is used as the modulation signal, and the corresponding switching signal with fixed frequency is generated by the shoot-through segment space vector pulse width modulation (SVPWM) technology. The simulation results show that the ES-qZSI realizes six shoot-through actions per control cycle and achieves the constant frequency control of the system, which verifies the correctness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 21-35
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modified scheme of predictive torque control for three-phase four-switch inverter-fed motor drive with adaptive DC-link voltage imbalance suppression
Autorzy:
Sobański, P.
Powiązania:
https://bibliotekanauki.pl/articles/1193409.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fault tolerant systems
semiconductor faults
four switch inverter
predictive control
cost function
variable speed drives
Opis:
Classical voltage space vector modulation techniques cannot be efficiently applied in four-switch three-phase voltage inverter-fed electrical drives due to a voltage offset in DC-link capacitors. The capacitor voltages imbalance is a result of a bidirectional current which flows in a phase of an electric motor that is connected to a DC-link capacitor midpoint. To overcome this problem which leads to an incorrect inverter voltage modulation or even can affect the DC-link capacitors, predictive control algorithms considering the voltage offset in DC-link capacitors have been developed. Despite the predictive methods are highly effective, they require to adjust the cost function weighting factors which is normally an inexplicit task. In this paper, an on-line tuning method of the weighting factor related to the capacitor voltages imbalance incorporated in the cost function of the predictive algorithm has been proposed. According to the proposed approach, the weighting factor is self-adjusted so that the DC-link capacitor voltages are stabilized as well as a high quality of the drive control is remained simultaneously, regardless of its operating point. The proposed strategy has been validated by using simulation model of the induction motor drive system.
Źródło:
Power Electronics and Drives; 2017, 2, 37/2; 93-101
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Space-vector pulsewidth modulation for a seven-level cascaded H-bridge inverter with the control of DC-link voltages
Autorzy:
Lewicki, A.
Morawiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/200099.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cascade H-bridge inverter
DC-link voltage control
space vector modulation
mostek H
sterowanie napięciem
modulacja
Opis:
A control strategy of DC-link voltages for a seven-level cascaded H-bridge inverter is proposed in this paper. The DC-link voltage balancing is accomplished by an appropriate selection of H-bridges and control of their duty cycles in space-vector modulation (SVM) algorithm. The proposed SVM method allows to maintain the same voltage level on all inverter capacitors. Regardless of the balancing function, the SVM strategy makes it possible to generate the output voltage vector properly also in the case where the DC-link voltages are not balanced. The results of simulation and experimental investigations are presented in the paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 619-628
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design, development and verification of a new multilevel inverter for reduced power switches
Autorzy:
Mahato, Bidyut
Ranjan, Mrinal
Pal, Pradipta Kumar
Gupta, Santosh Kumar
Mahto, Kailash Mahto
Powiązania:
https://bibliotekanauki.pl/articles/2172807.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
7-level/13-level inverter
DC-AC converters
power-electronic switches
sinusoidal PWM
Opis:
Due to recent developments in the field of high-power and medium-voltage, the multilevel inverter has raised to such an extent owing to some of its amazing facts regarding harmonic spectrum, ease in control, reduced electromagnetic interference (EMI), filterless circuit, stress on power switches, common-mode voltage. This paper well describes a novel architecture of a single-phase multilevel inverter using a lesser number of overall components, especially the power switches. The proposed topology is generalized in the structure that can generate any number of voltage steps. A 7-level structure of the proposed topology is explained and is elaborately discussed. Simulation is carried out in MATLAB and corresponding experimental results verify the existence of the proposed multilevel inverter. The real-time experimental results were presented and are well verified by the simulation results for 7-level as well for 13-level across RL-Load. The nature of load current is also indicated as per the nature of load voltage. Nevertheless, the topology is further compared with some of the recent literature and found superior in each respect.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 1051--1063
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Falownik napięciowy oparty na potrójnym mostku H do zasilania silnika trójfazowego z przerwaną fazą
Three phase motor with open phase supplied from voltage inverter based on triple h bridge
Autorzy:
Radecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1369107.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
falownik napięcia
silnik trójfazowy
three-phase motor
voltage inverter
Opis:
In this paper, a voltage inverter based on three independent H-bridges to supply health and faulty motor was presented. Operating conditions of this type of inverter were presented for each open phase. For proposed control scheme that refers to independent control of each phase current, a robust properties of control system was shown. Based on computer simulations and laboratory tests, the effectiveness of squirrel cage induction motor control, supplied from three independent H-bridges was shown in case of dynamic phase opening.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 1, 94; 115-120
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling and simulation of sinusoidal pulse width modulation controller for solar photovoltaic inverter to minimize the switching losses and improving the system efficiency
Autorzy:
Panneerselvam, Sivaraj
Kandasamy, Karunanithi
Perumal, Chandrasekar
Powiązania:
https://bibliotekanauki.pl/articles/2135736.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
efficiency
IGBT
MOSFET
PV inverter
MATLAB/SIMULINK
SPWM controller
switching loss
Opis:
With the extinction of fossil fuels and high increase in power demand, the necessity for renewable energy power generation has increased globally. Solar PV is one such renewable energy power generation, widely used these days in the power sector. The inverters used for power conversion suffer from power losses in the switching elements. This paper aims at the detailed analysis on switching losses in these inverters and also aims at increasing the efficiency of the inverter by reducing losses. Losses in these power electronic switches vary with their types. In this analysis the most widely used semiconductor switches like the insulated gate bipolar transistor (IGBT) and metal oxide semiconductor field effect transistor (MOSFET) are compared. Also using the sinusoidal pulse width modulation (SPWM) technique, improves the system efficiency considerably. Two SPWM-based singlephase inverters with the IGBT and MOSFET are designed and simulated in a MATLAB Simulink environment. The voltage drop and, thereby, the power loss across the switches are compared and analysed. The proposed technique shows that the SPWM inverter with the IGBT has lower power loss than the SPWM inverter with the MOSFET.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 615--626
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The DC-side active filter with dual-buck full-bridge inverter for wind generators
Autorzy:
Chen, X-Q.
Zhao, S-W.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/141358.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-pulse ac-dc converter
auto-transformer
harmonic suppression
DC-side active filter
dual-buck full-bridge inverter
Opis:
This paper proposes a new dc-side active filter for wind generators that combines 12-pulse polygon auto-transformer rectifier with dc-side current injection method and dual-buck full-bridge inverter having not the “shoot-through” problem in conventional bridge-type inverters, and therefore this system with the character low harmonic distortion and high reliability. The proposed dc-side active filter is realized by using dual-buck full bridge converter, which directly injects compensation current at dc-side of two six-pulse diode bridges rectifiers. Compared with the conventional three-phase active power filter at ac-side, the system with the dc-side active filter draws nearly sinusoidal current by shaping the diode bridges output current to be triangular without using the instantaneous reactive power compensation technology, only using simple hysteretic current control, even though under load variation and unbalanced voltage disturbances, and while an acceptable linear approximation to the accurate waveform of injection current is recommended. The performance of the system was simulated using MATLAB/Simulink, and the possibility of the dc-side active filter eliminating current harmonics was confirmed in steady and transient states. The simulation results indicate, the system has a total harmonic distortion of current reduced closely to 1%, and a high power factor on the wind generator side.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 263--277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja parametrów modelu matematycznego falownikowego napędu trakcyjnego z silnikiem PMSM
Identification of mathematical model parameters of traction inverter drive system with PMSM motor
Autorzy:
Stefański, T.
Zawarczyński, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/315671.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
falownikowy napęd trakcyjny
silnik PMSM
model matematyczny
traction inverter drive system
PMSM motor
mathematical model
Opis:
Analizowano problem modelowania matematycznego i identyfikacji parametrycznej napędu falownikowego z silnikiem synchronicznym ze wzbudzeniem od magnesów trwałych (PMSM). Do identyfikacji parametrów modelu matematycznego napędu zastosowano numeryczną metodę optymalizacji statycznej Box’a (metoda complex). Badania laboratoryjne przeprowadzono dla falownikowego napędu z silnikiem PMSM o mocy 2,5 kW.
The problems of mathematical modelling and parameter identification of traction inverter drive system with PMSM motor were analysed. The numerical Box’s method of static optimisation has been applied in parametric identification of the drive system. Parameters of the mathematical models were determined according to minimisation of the meansquare error of the stator current and of the angular velocity. The experimental verification was carried out for the laboratory model of the inverter drive system with PMSM motor of 2,5 kW.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 6; 1138-1143
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid-Tied Neutral Point Clamped based Centralised Photovoltaic Inverter with Improved DC Link Voltage Balancing and Harmonic Minimisation Control
Autorzy:
Bhowmick, Supratik
Mukherjee, Debranjan
Maiti, Suman
Chakraborty, Chandan
Powiązania:
https://bibliotekanauki.pl/articles/1955983.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
photovoltaic multilevel inverter
neutral point voltage balancing
space vector pulse width modulation
current harmonic minimisation
Opis:
This paper proposes an improved space vector pulse width modulation (SVPWM) based DC link voltage balancing control of a three-phase three-level neutral point clamped (NPC) centralised inverter supplying the generated power from photo voltaic (PV) array to a three-phase utility grid. Two possible schemes have been developed based on the power conversion stage between PV array and the utility grid namely, two-stage (three-level boost converter three-phase three-level NPC inverter) and single-stage (three-phase three-level NPC inverter alone). The comparison between these two schemes has been thoroughly discussed in terms of the control strategies employed, power loss analysis and efficiency. The performance of the centralised inverter under different modes of operation has been investigated by developing the required control strategies for smooth operation. Using the proposed control strategy, the centralised inverter can be operated as a static synchronous compensator (STATCOM) during night time, if needed. The power loss incurred in the power-electronic converters has been analysed for constant and also for variable ambient temperature. The effectiveness of the centralised inverter as an active filter (AF) has also been verified when a three-phase non-linear load is considered in the system.
Źródło:
Power Electronics and Drives; 2021, 6, 41; 185-203
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical method of a calculation of a torque ripple of a two-phase asynchronous motor supplied by a pwm controlled inverter
Metoda analityczna obliczania pulsacji momentu dwufazowego silnika asynchronicznego zasilanego z falownika PWM
Autorzy:
Záskalický, P.
Powiązania:
https://bibliotekanauki.pl/articles/1368690.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
asynchronous motor
PWM controlled inverter
modeling
analytical method
Opis:
The paper deals with steady state calculation of torque and currents ripples of a two-phase asynchronous machine, which is supplied by an IGBT transistors half-bridge connected inverter. The inwerter output voltage is controlled by a PWM of the input DC voltage. The complex Fourier series analysis of the inverter output voltage was made, to obtain a spectrum of the harmonic supply voltages. The different voltage harmonic was applied to the two-phase induction machine model to obtain the electromagnetic torque and currents waveforms for various operation conditions.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 131-135
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of space vector modulation algorithm on characteristics of three-phase voltage inverter for drives of optical telescopes
Autorzy:
Tomasov, V.
Usoltsev, A.
Zolov, P.
Gribanov, P.
Powiązania:
https://bibliotekanauki.pl/articles/200303.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multilevel inverter
space vector modulation
modulation algorithm
current ripple
precision AC drive
inwerter
modulacja
napęd AC
Opis:
The effect of space vector modulation algorithm on magnitude of current vector ripples was considered on the mathematical model of a three-level three-phase voltage inverter with symmetric active inductive load. Limitations on the use of such inverters as a power supply for precision drive of optical telescopes were specified.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 629-637
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sub-phase power electronics inverters
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/97361.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
inverter
Generalized Sampling Expansion
Whittaker-Kotelnikov-Shannon sampling theorem
WKS
Opis:
Dynamic changes of parameters of energy sources and receivers are reasons that decrease exactitude of output signals towards reference signals. To improve these parameters more advanced solutions of power electronics systems are necessary. Ones of possible solutions are a sub-phase inverters. The output quantity regulator there is based on Generalized Sampling Expansion, being crucial extension of Whittaker-Kotelnikov-Shannon sampling theorem. Wide-band power electronics current source with regulator based on that extension is analyzed further.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 190-199
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Resonant DC link inverters for AC motor drive systems – critical evaluation
Autorzy:
Turzyński, Marek
Chrzan, P. J.
Powiązania:
https://bibliotekanauki.pl/articles/200688.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft-switching
resonant DC link inverter
quasiresonant DC link inverter
common-mode voltage
voltage gradient
zero voltage switching
przekształtnik quasirezonansowy DC
gradient napięcia
przekształtnik rezonansowy DC/DC
Opis:
In this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing and winding insulation safety. Experimental records of the laboratory developed parallel quasiresonant DC link inverter feeding induction motor confirm results of analysis. Comparative tables and simulation results demonstrate characteristic features of various schemes.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 2; 241-252
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single-source three-phase switched-capacitor-based MLI
Autorzy:
Jena, Kasinath
Gupta, Krishna Kumar
Bhatnagar, Pallavee
Jain, Sanjay K.
Stala, Robert
Waradzyn, Zbigniew
Piróg, Stanisław
Penczek, Adam
Mondzik, Andrzej
Skała, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/2175942.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
multilevel inverter
switched capacitor
multicarrier pulse width modulation
cost function
ANPC inverter
Opis:
This article proposes a novel three-phase inverter based on the concept of switched capacitors (SCs), which uses a single DC source. A three-phase, seven-level line-to-line output voltage waveform is synthesised by the proposed topology, which includes eight switches, two capacitors, and one diode per phase leg. The proposed topology offers advantages in terms of inherent voltage gain, lower voltage stresses on power switches, and a reduced number of switching components. Additionally, the switched capacitors are self-balanced, thereby eliminating the need for a separate balancing circuit. The proposed structure and its operating principle, the self-balancing mechanism of the capacitors, and the control strategy are all thoroughly explained in the article. The proposed topology has also been compared with some recent SC topologies. Lastly, the proposed topology has been shown to be feasible through simulation and experimentation.
Źródło:
Power Electronics and Drives; 2022, 7, 42; 197--209
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Transformer Class E Amplifier
Autorzy:
Mikolajewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141694.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Class E amplifier
resonant inverter
DC-DC converter
transformer
leakage inductance
Opis:
In a high-efficiency Class E ZVS resonant amplifier a matching and isolation transformer can replace some or even all inductive components of the amplifier thus simplifying the circuit and reducing its cost. In the paper a theoretical analysis, a design example and its experimental verification for a transformer Class E amplifier are presented. In the experimental amplifier with a transformer as the only inductive component in the circuit high efficiency ηMAX = 0.95 was achieved for supply voltage VI = 36 V, maximum output power POMAX = 100 W and the switching frequency f = 300 kHz. Measured parameters and waveforms showed a good agreement with theoretical predictions. Moreover, the relative bandwidth of the switching frequency was only 19% to obtain output power control from 4.8 W to POMAX with efficiency not less than 0.9 in the regulation range.
Źródło:
Archives of Electrical Engineering; 2014, 63, 4; 621-633
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cyfrowy automat sterujący urządzeń energoelektronicznych z wykorzystaniem modelu czasu rzeczywistego falownika
Digital state machine of power electronic device with the use of inverter’s real-time model
Autorzy:
BINKOWSKI, Tomasz
KWIATKOWSKI, Bogdan
Powiązania:
https://bibliotekanauki.pl/articles/456633.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rzeszowski
Tematy:
model czasu rzeczywistego
energoelektronika
falownik
sterowanie
real-time model
power electronic
inverter
control
Opis:
Artykuł przedstawia koncepcję stanowiska laboratoryjnego przeznaczonego do badań układów sterowania przekształtników energoelektronicznych. Zakłada się, że przekształtnik energoelektroniczny symulowany jest sprzętowo jako współbieżny proces w stosunku do testowanego układu sterowania. Jako platformę sprzętową wykorzystuje się układ o programowalnej strukturze logicznej umożliwiający testowanie procesu sterowania na modelu czasu rzeczywistego przekształtnika lub bezpośrednie sterowanie modelem laboratoryjnym. Jako przykład przedstawiono cyfrowy model falownika napięcia sterowany automatem realizującym przełączanie półokresowe. Prezentowana koncepcja ma zastosowanie w badaniach naukowych i dydaktyce.
The article presents the concept of the laboratory stand for testing of power electronic control systems. It is assumed that the converter unit and the control process are simulated in parallel as a hardware. The hardware platform uses the programmable logical structure for testing the control process on real time inverter model or can directly control the laboratory inverter model. The digital model of the inverter voltage controlled by digital state machine that makes half-period switching was used as an example. The presented concept is applicable in scientific research and teaching.
Źródło:
Edukacja-Technika-Informatyka; 2016, 7, 4; 387-393
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania eksploatacyjne elektrycznego układu napędowego z falownikiem igbt samochodu Fiat Panda 2
Exploitation tests of an electric powertrain with IGBT inverter for an EV Fiat Panda 2
Autorzy:
Łebkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/305007.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
pojazd elektryczny
napęd elektryczny
silnik synchroniczny
falownik IGBT
electric powertrain
synchronous motor
electric vehicle
IGBT inverter
Opis:
W artykule zaprezentowano wyniki badań eksploatacyjnych układu napędowego zaimplementowanego w samochodzie osobowym Fiat Panda 2. Przedsięwzięcie podjęte przez Akademię Morską w Gdyni we współpracy z firmą ELTE GPS oraz firmą Auto-Mobil zaowocowało skonstruowaniem kilkunastu pojazdów tego typu, które eksploatowane są do dnia dzisiejszego w różnych regionach Polski, a w szczególności przez koncerny energetyczne. W trakcie eksploatacji parametry elektrycznego układu napędowego były monitorowane i rejestrowane. Na podstawie dokonanych zapisów przedstawiono wyniki testów drogowych. W pracy przedstawiono konstrukcje oraz podzespoły zastosowane do konwersji pojazdu spalinowego na elektryczny, zawierające takie elementy, jak: trakcyjny silnik napędowy, falownik IGBT, pakiet akumulatorów wraz z systemem kondycjonowania klimatycznego i ładowarką, przetwornice DC/DC, a także komputer pokładowy wraz z cyfrową magistralą danych i zestawem wskaźników. Przedstawiono także dobór parametrów poszczególnych podzespołów, a w szczególności falownika IGBT oraz systemu BMS. W końcowej części pracy zamieszczono wyniki badań weryfikacyjnych związanych z osiąganymi parametrami eksploatacyjnymi przez pojazd, takimi jak moc układu napędowego, prędkość maksymalna, zużycie energii (zasięg w cyklu miejskim i pozamiejskim).
The article presents the results of utilization testing of an electric powertrain implemented in a Fiat Panda 2 car. The project was undertaken by Gdynia Maritime University in cooperation with ELTE GPS and Auto-Mobil, and it resulted in construction of several cars of this type, which are operated to this day in various regions of Poland, mainly by electrical energy distribution companies. All powertrain parameters were monitored and recorded during the project, and it allowed to compile, and present in the article a comprehensive road test report. Additionally, the paper presents the overview of elements used to convert a vehicle from internal combustion to electric propulsion, such as: the traction motor, the IGBT inverter, the battery pack with charger and climatic control unit, the DC/DC converter as well as an on-board computer with digital data bus and an instrument cluster. A method of tuning the parameters of sub-systems, especially the IGBT inverter and the Battery Management System. The article concludes with verification tests run in order to check the car’s achievable operational parameters, such as: maximal powertrain power, top speed and energy consumption in both urban and extra-urban conditions.
Źródło:
Napędy i Sterowanie; 2017, 19, 11; 88-93
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania eksploatacyjne elektrycznego układu napędowego z falownikiem IGBT samochodu Fiat Panda 2
Exploitation tests of an electric powertrain with IGBT inverter for an ev Fiat Panda
Autorzy:
Łebkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1201852.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
pojazd elektryczny
napęd elektryczny
silnik synchroniczny
falownik IGBT
electric vehicle
electric powertrain
synchronous motor
IGBT inverter
Opis:
The article presents the results of utilization testing of an electric powertrain implemented in a Fiat Panda 2 car. The project was undertaken by Gdynia Maritime Academy in cooperation with ELTE GPS and Auto-Mobil, and it resulted in construction of several cars of this type, which are operated to this day in various regions of Poland, mainly by electrical energy distribution companies. All powertrain parameters were monitored and recorded during the project, and it allowed to compile and present in the article a comprehensive road test report. Additionally, the paper presents the overview of elements used to convert a vehicle from internal combustion to electric propulsion, such as: the traction motor, the IGBT inverter, the battery pack with charger and climatic control unit, the DC/DC converter as well as an on-board computer with digital data bus and an instrument cluster. A method of tuning the parameters of sub-systems, especially the IGBT inverter and the Battery Management System. The article concludes with verification tests run in order to check the car’s achievable operational parameters, such as: maximal powertrain power, top speed and energy consumption in both urban and extra-urban conditions.
W artykule zaprezentowano wyniki badań eksploatacyjnych układu napędowego zaimplementowanego w samochodzie osobowym Fiat Panda 2. Przedsięwzięcie podjęte przez Akademię Morską w Gdyni we współpracy z firmą ELTE GPS oraz firmą Auto-Mobil zaowocowało skonstruowaniem kilkunastu pojazdów tego typu, które eksploatowane są do dnia dzisiejszego w różnych regionach Polski, a w szczególności przez koncerny energetyczne. W trakcie eksploatacji parametry elektrycznego układu napędowego były monitorowane i rejestrowane. Na podstawie dokonanych zapisów, przedstawiono wyniki testów drogowych. W pracy przedstawiono konstrukcje oraz podzespoły zastosowane do konwersji pojazdu spalinowego na elektryczny zawierające takie elementy jak: trakcyjny silnik napędowy, falownik IGBT, pakiet akumulatorów wraz z systemem kondycjonowania klimatycznego i ładowarką, przetwornice DC/DC, a także komputer pokładowy wraz z cyfrową magistralą danych i zestawem wskaźników. Przedstawiono także dobór parametrów poszczególnych podzespołów, a w szczególności falownika IGBT oraz systemu BMS. W końcowej części pracy zamieszczono wyniki badań weryfikacyjnych związanych z osiąganymi parametrami eksploatacyjnymi przez pojazd, takimi jak moc układu napędowego, prędkość maksymalna, zużycie energii (zasięg w cyklu miejskim i pozamiejskim).
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 1, 109; 25-30
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ przemienników częstotliwości na pracę silników indukcyjnych w podziemiach kopalń
Influence of frequency innverters on operation of induction motors in mine environment
Autorzy:
Marek, A.
Powiązania:
https://bibliotekanauki.pl/articles/113133.pdf
Data publikacji:
2017
Wydawca:
STE GROUP
Tematy:
pośredni przemiennik częstotliwości
falownik
MSI
silnik indukcyjny
przepięcie
prąd doziemny
intermediate frequency inverter
inverter
PWM
induction motor
overvoltage
earth leakage current
Opis:
W referacie przedstawiono analizę współpracy pośrednich przemienników częstotliwości z zasilanymi przez nie silnikami indukcyjnymi. Na warunki pracy silników zasilanych z pośrednich przemienników częstotliwości mają w warunkach kopalnianych wpływ parametry elementów pasożytniczych użytych przewodów oponowych lub/i kabli górniczych, parametry elementów wchodzących w skład filtrów oraz sposób sterowania pracą zaworów falownika. Istotną właściwością omawianego przekształtnika jest to, że nie jest on źródłem napięcia sinusoidalnie zmiennego. Odkształcenie napięcia wyjściowego przemiennika jest efektem wielokrotnej komutacji zaworów falownika pracującego przy sterowaniu z modulacją szerokości impulsów (MSI). Z komutacją zaworów falownika związane są duże stromości narastania napięcia wyjściowego przemiennika. Stromości te osiągają wartości dochodzące do kilkunastu kV na s. Tak duże stromości narastania napięcia wyjściowego przemiennika powodują w stanie przejściowym przepływ dużych prądów pojemnościowych. W pracy omówiono wpływ poszczególnych parametrów kabli i przewodów oponowych na wartości przepięć i prądów doziemnych. Omówiono również sposoby ograniczenia tych niekorzystnych zjawisk (przepięć, prądów doziemnych).
The paper contains analysis of cooperation between induction motors with the intermediate frequency inverters that supply them. In the mine environment, parasitic elements of the cables, parameters of the filters’ elements, and a method of control over inverter transistors have an impact on the regime of motors fed by the intermediate frequency inverters. An important feature of such a converter is that it is not a source of sinusoidal voltage. Deformation of voltage output is a result of inverter transistors being switched up multiple times with pulse – width modulation (PWM) control. Large steepness of the converter output rising voltage is related to switching of the transistors. The steepness reaches values of up to a dozen or so kV on s. Such a large steepness of output rising voltage can cause passage of large capacitive currents. The paper discusses also the influence of the parameters of individual cables on values of the overvoltages and earth leakage currents. Various ways to limit this negative phenomena (overvoltage, the earth leakage current) are also discusses in the paper.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2017, 6, 2; 188-196
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wysokoczęstotliwościowy falownik napięcia badania symulacyjne
High frequency inverter simulation research
Autorzy:
Judek, S.
Karwowski, K.
Korycki, K.
Soczyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/268280.pdf
Data publikacji:
2005
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Opis:
W opracowaniu przeprowadzono analizę układu bezstykowego przesyłania energii elektrycznej dla stanu ustalonego przy wymuszeniu sinusoidalnym. Obliczenia te oparto na transformatorowym schemacie zastępczym układu cewek powietrznych sprzężonych magnetycznie. Analiza ta umożliwiła określenie struktury i obszaru pracy układu charakteryzującej się maksymalną sprawnością. Następnie przedstawiono wyniki symulacji układu przy zasilaniu przekształtnikowym, z uwzględnieniem modeli rzeczywistych elementów energoelektronicznych. Przedstawione rezultaty wskazują na to, że układ jest w stanie przekazywać energię elektryczną o określonych parametrach również w przypadku dynamicznie zmieniających się jego parametrach, w szczególności współczynnika sprzężenia magnetycznego.
This paper describes a technique, the contactless electrical energy transfer system (CEETS), by which electrical energy may be transmitted, without electrical connection or physical contact, through the large air gap. CEETS is becoming more and more attractive especially for automatic battery charging stations and for energy supply of inductively powered electric vehicles and other movable consumers. Authors presented theoretical and simulation analysis of transformer equivalent circuit with capacitors series and parallel connected to windings. The analysis includes supply via AC voltage source and power electronics converter with invariable and with variable frequency. The calculations are oriented in order to show compensation topology which is characterized greatest efficiency.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2005, 21; 125-130
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault diagnosis of T-type three-level inverter based on bridge voltages
Autorzy:
Chen, Danjiang
Liu, Yutian
Zhang, Shaozhong
Powiązania:
https://bibliotekanauki.pl/articles/1841372.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bridge voltage
fault diagnosis
fault signal
open-circuit fault
T-type three-level inverter
napięcie mostka
błędna diagnoza
sygnał błędu
błąd obwodu otwartego
falownik trójpoziomowy typu T
Opis:
Multilevel inverters have been widely used in various occasions due to their advantages such as low harmonic content of the output waveform. However, because multilevel inverters use a large number of devices, the possibility of circuit failure is also higher than that of traditional inverters. A T-type three-level inverter is taken as the research object, anda diagnostic study is performed on the open-circuit fault of insulated gate bipolar transistor (IGBT) devices in the inverter. Firstly, the change of the current path in the inverter when anopen-circuit fault of the device occurred, and the effect on the circuit switching states andthe bridge voltages were analyzed. Then comprehensively considered the bridge voltages,and proposed a fault diagnosis method for a T-type three-level inverter based on specificfault diagnosis signals. Finally, the simulation verification was performed. The simulation results prove that the proposed method can accurately locate the open-circuit fault of theinverter device, and has the advantage of being easy to implement.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 73-87
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Phase-Shift Driven Class D Series Resonant Inverter With Two Anti Parallel-Connected Auxiliary Switches
Sterowany fazowo przekształtnik rezonansowy klasy D z dwoma łącznikami połączonymi odwrotnie równolegle
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/151193.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
miękkie przełączanie
ZCS
sterowanie fazowe
przekształtnik klasy D
soft switching
phase-shift control
class D inverter
Opis:
This paper presents analysis of a novel voltage source class D inverter. The classic topology has been extended of the two auxiliary switches, that are anti parallel connected and each of them has its own resonant inductor. Proposed solution enables phase-shift control of the inverter, keeping zero-current-switching for auxiliary transistors. This paper explains the operation principle that is illustrated by simulation, presents general equations, design and shows experimental results.
W artykule zaprezentowano analizę nowego rozwiązania przekształtnika klasy D, zasilanego ze źródła napięcia. Układ klasycznego przekształtnika został rozszerzony o dwa dodatkowe klucze, które są połączone przeciw równolegle i posiadają własne indukcyjności stanowiące elementy obwodu rezonansowego. Zaproponowane rozwiązanie umożliwia sterowanie fazowe przekształtnika, przy zachowaniu wyłączania tranzystorów pomocniczych w warunkach zerowego prądu - ZCS. Artykuł przedstawia podstawowe równania, budowę i wyniki badań eksperymentalnych przekształtnika.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 2, 2; 56-59
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of asymmetrical currents waveforms to detect and localize open switch faults for two level voltage source inverter three-phase shunt active power filter
Autorzy:
Benslimane, T.
Chetate, B.
Abdelkrim, T.
Powiązania:
https://bibliotekanauki.pl/articles/229453.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active power filter
fault detection
two level there phase voltage source inverter
current mean value
Opis:
This paper proposes an open switch faults detection and localization algorithm for shunt three phase active filter topology. It mainly details converter configuration and examines a simple and reliable optimized fault diagnosis method. The converter topology is based on classical three-leg active power filter topology. New fault diagnosis method is proposed, based on classical currents measurements. It includes combinatory logic to analyze and validate error signals. Hysteresis control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the effectiveness of this method.
Źródło:
Archives of Control Sciences; 2011, 21, 1; 105-117
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odzyskiwanie energii elektrycznej w aplikacjach napędowych z falownikami Danfoss Drives
Autorzy:
Ptaszyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/304909.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
falownik
energia elektryczna
hamowanie
inverter
electricity
braking
Opis:
W artykule przygotowanym przez firmę Schulz Infoprod, która od wielu lat jako Autoryzowany Dystrybutor współpracuje z Danfoss, przedstawiono rozwiązania kontroli energii oddawanej przez napęd w trakcie dynamicznego hamowania.
Źródło:
Napędy i Sterowanie; 2017, 19, 3; 28-30
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary napięcia zasilania stojana silnika w napędzie falownikowym
Measurements of stator voltage in the inverter-fed drive system
Autorzy:
Zawarczyński, Ł.
Stefański, T.
Powiązania:
https://bibliotekanauki.pl/articles/314146.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
napęd falownikowy
stojan silnika
napięcie fazowe
napięcie międzyfazowe
pomiar wartości chwilowej
inverter-fed drive system
motor stator
phase voltage
interphase voltage
measurement of temporary values
Opis:
W artykule przedstawiono analizę układów pomiarowych napięć stojana silnika zasilanego z falownika napięcia. Badania eksperymentalne układów pomiarowych przeprowadzono pod kątem oceny ich pasma przenoszenia, właściwości dynamicznych i dokładności pomiaru. Przedstawiono metody pomiaru wartości chwilowych napięć fazowych i międzyprzewodowych. Testy eksperymentalne przeprowadzono na stanowisku badawczym napędu falownikowego z silnikiem asynchronicznym o mocy 2,6 kW.
This paper presents an analysis of the measuring systems of the stator voltage of inverter-fed motor drive system. Experimental tests of measurement systems were carried out to calculate their bandwidth, dynamic properties and accuracy. The methods of measuring the temporary values of the phase voltages and interphase voltages. Experimental tests were carried out on the inverter-fed drive system with asynchronous motor with a power of 2,6 kW.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 1514-1518
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A state-space approach for control of NPC type 3-level sine wave inverter used in FOC PMSM drive
Autorzy:
Tarczewski, T.
Grzesiak, L. M.
Wawrzak, A.
Karwowski, K.
Erwiński, K.
Powiązania:
https://bibliotekanauki.pl/articles/200731.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
state feedback control
linear quadratic regulator
3-level neutral point clamped voltage source inverter
LC filter
Opis:
This paper presents the design and analysis process of state feedback controllers for NPC type 3-level sine wave inverter. In order to achieve good dynamic features in a state feedback control an internal model of reference input and a feedforward path are introduced. During synthesis process of the state feedback controllers maximum permissible dynamics of voltage control in the linear range of modulation is taken into account. It is shown that initially gains of the controller and feedforward path are non-stationary and depend on the angular velocity. Stationary approximation of a non-stationary state feedback controller is presented in details. Proposed state feedback control structures for continuous voltage shaping NPC type 3-level voltage source inverter are examined in FOC PMSM drive. The novelty of the presented controller lays in a stationary approximated state feedback control structure designed in terms of maximum permissible dynamics of a voltage control system. Simulation and experimental results (at the level of 3 kW) of the designed control algorithms are included.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 3; 439-448
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
HF INVERTER POLSKA. Scentralizowana czy zdecentralizowana technika napędowa?
Autorzy:
Snowacki, M.
Powiązania:
https://bibliotekanauki.pl/articles/304437.pdf
Data publikacji:
2016
Wydawca:
Wydawnictwo Druk-Art
Tematy:
technika napędowa
mechatronika
sterowanie centralne
drive technology
mechatronics
central control
Opis:
Centralizacja i decentralizacja napędów to bardzo interesujące zagadnienie, które stało się klasycznym tematem badawczym w ramach mechatroniki, w szczególności w technice napędowej. Jest też problemem w kontekście nieustającego, a być może w ogóle niemożliwego do rozstrzygnięcia, sporu o przewadze jednego rozwiązania nad drugim. W wielu branżach dochodzi do zderzenia dwóch przeciwstawnych tendencji: z jednej strony chodzi o zachowanie sterowania centralnego, gdyż zapewnia ono unifikację rozwiązania technicznego, a tym samym wyrównuje różnice w zależnych od siebie procesach technologicznych, z drugiej zaś strony uważa się, że pożądane byłoby stopniowe powiększanie zakresu decentralizacji napędów ze względu na niższe koszty.
Źródło:
Napędy i Sterowanie; 2016, 18, 12; 14-16
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved virtual space vector modulation for neutral point voltage oscillation and common-mode voltage reduction in neutral point clamped three-level inverter
Autorzy:
Fang, Junlong
Wang, Guangya
Li, Ran
Liu, Siyuan
Wang, Shuyu
Powiązania:
https://bibliotekanauki.pl/articles/1841339.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-level inverter
vector conversion
virtual space vector modulation
falownik trójpoziomowy
konwersja wektorowa
modulacja wektora przestrzeni wirtualnej
Opis:
The neutral point clamped (NPC) three-level inverter is widely used in high-voltage and high-power applications. However, neutral point voltage oscillation (NPVO) and common-mode voltage (CMV) problems exist in the NPC three-level inverter. In this paper, an improved virtual space vector modulation (VSVM) is proposed based on the reconstruction of a virtual small vector and a virtual medium vector. Compared with the traditional VSVM, an improved VSVM can effectively reduce the CMV. On this basis, a vector conversion method is proposed to further reduce the NPVO in the whole range. Simulation results verify the effectiveness and superiority of the improved VSVM.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 203-218
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current ripple reduction for finite control set model predictive control strategy of grid-tied inverter with reference current compensation
Autorzy:
Jin, Nan
Fan, Wuchuang
Fang, Jie
Wu, Jie
Shen, Yongpeng
Powiązania:
https://bibliotekanauki.pl/articles/2202542.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cost function
current ripple reduction
finite control set model predictive control
FCS-MPC
grid-tied inverter
reference current compensation
RCC
Opis:
In the finite control set model predictive control (FCS-MPC) strategy of the grid-tied inverter, the current ripple (CR) affects the selection of optimal voltage vectors, which leads to the increase of output current ripples. In order to solve this problem, this paper proposes a CR reduction method based on reference current compensation (RCC) for the FCS-MPC strategy of grid-tied inverters. Firstly, the influence of the CR on optimal voltage vector selection is analyzed. The conventional CR prediction method is improved, which uses inverter output voltage and grid voltage to calculate current ripples based on the space state equation. It makes up for the shortcomings that the conventional CR prediction method cannot predict in some switching states. The improved CR method is more suitable for the FCS-MPC strategy. In addition, the differences between the two cost functions are compared through visual analysis. It is found that the sensitivity of the square cost function to small errors is better than that of the absolute value function. Finally, the predicted CR is used to compensate the reference current. The compensated reference current is substituted into the square cost function to reduce the CR. The experimental results show that the proposed method reduces the CR by 47.3%. The total harmonic distortion (THD) of output current is reduced from 3.86% to 2.96%.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 5--22
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PQ Cootrol of Photovoltaic Power Statioo in Microgrid Operation
Autorzy:
Cygan, S.
Łukowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/410543.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
inverter PQ control
PowerSys microgrid model
microgird control
Opis:
The numerical modelling of the photovoltaic module and the solar inverter interconnected with the microgrid has been carried out with the use of PowerSys in Matlab/Simulink. Algorithms of P, Q controllers have been proposed. The capability of the active and reactive power reference tracking has been tested for various conditions.
Źródło:
Present Problems of Power System Control; 2017, 8; 51-59
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamiczna regulacja mocą przekształtników sieciowych
Dynamic power control of the grid converters
Autorzy:
Zieliński, D.
Powiązania:
https://bibliotekanauki.pl/articles/407678.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
przekształtnik
VOC
LVRT
Simulink
inverter
PI algorithm
Opis:
Dynamicznie rozwijający się sektor źródeł odnawialnych zmusza urząd regulacji energetycznej do wprowadzania coraz bardziej rygorystycznych norm odnośnie jakości dostarczanej energii i dynamiki samych źródeł. W przyszłości przepisy będą wymagały by źródło energii odnawialnej własnościami dynamicznymi przypominało generator synchroniczny o równoważnej mocy. Ponadto źródło powinno własności tłumienia oscylacji mocy w systemie elektroenergetycznym i powinno wspomagać sieć w odbudowie napięcia. Powyższe przyczyny implikują sterowanie nieliniowe wysokiej dynamiki układów pośredniczących pomiędzy źródłem a siecią jakim są przekształtniki. Artykuł prezentuje regulator nieliniowy poprawiający dynamikę sterowania mocą w układach przekształtników wektorowych. Analizę dokonano za pomocą oprogramowania Matlab/SIMULINK.
The dynamic growth of the renewable energy sources sector causes that the Energy Regulatory Office introduces stricter and stricter grid codes about quality of the energy and dynamics of the sources. In the future, grid codes will require that the dynamic properties of the renewable source of energy is similar to the synchronous generator with the same power. Moreover, the renewable source of energy should damp power oscillation in power grid, and support it to stabilize the voltage. These causes lead us to use a high dynamic nonlinear control system – converters, installed between a source and a power grid. The paper presents a nonlinear controller improves the dynamic power control of the vector inverters’ systems. The analysis was made by using the MATLAB/Simulink software.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 1; 59-62
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced control and design methods of the auxiliary resonant commutated pole inverter
Autorzy:
Karyś, S.
Powiązania:
https://bibliotekanauki.pl/articles/201964.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
soft switching
ARCP
ZVS
miękkie przełączanie
tranzystor
Opis:
This paper presents several methods that enable the reduction of power loss in the auxiliary resonant commutated pole inverter - ARCP. Presented methods can be divided into static and dynamic ones. The static methods are related to an appropriate design of the inverter, whereas dynamic ones to advanced control of the power transistors. A variety of design and control methods are presented together with their advantages and disadvantages. The new control method of the current in the resonant branch is described. The main benefits of the proposed extended control method and their constrains are shown.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 489-494
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
Single-phase inverter with active power decoupling
Autorzy:
Czyż, P.
Cichowski, A.
Śleszyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/267988.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
falownik jednofazowy
odsprzęganie składowej przemiennej mocy chwilowej
sterowanie przekształtnikiem
tranzystor z węglika krzemu
SiC
single-phase inverter
decoupling of the alternating component of the instantaneous power
converter control
silicon carbide transistors
Opis:
Znanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy. W pracy przedstawiono ideę aktywnego odsprzęgania mocy na przykładzie układu podwyższającego napięcie. Następnie zaprezentowano sposób doboru elementów obwodu odprzęgającego oraz przyjętą strategię sterowania. Zaproponowany model zweryfikowano w programie symulacyjnym oraz zaimplementowano w zbudowanym modelu laboratoryjnym falownika. W badaniach laboratoryjnych osiągnięto znaczną redukcję składowej prądu wejściowego o częstotliwości dwukrotnie większej od częstotliwości podstawowej falownika oraz sprawność powyżej 94%.
In single-phase inverters the instantaneous output power contains a DC component and a double line frequency power oscillation. To cope with the issue of inducing a significant current and voltage ripples on the DC side, the most popular approach is to decouple DC and AC sides with a bulky bank of electrolytic capacitors. This method is however reducing the reliability, life-time and power density of a converter. Most recently active power decoupling methods are gaining popularity as an alternative approach to solve this issue. In this paper a film capacitor based active power decoupling method in a boost topology is presented. First of all, the methods of DC active power decoupling, the principle of decoupling in a boost topology and selection of decoupling circuit elements are given. Then, the proposed control strategy is described and verified by the simulation. Finally, a constructed prototype of the single-phase inverter is presented and measurements at 500 W output power are conducted. The obtained results proves the feasibility of the identified approach and also high power efficiency of 94% is achieved.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 17-20
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wektorowy falownik napięciowy z pomiarem rzeczywistego napięcia wyjściowego
Voltage Inverter with True Output Voltage Measurement System
Autorzy:
Nowak, R.
Chudzik, P.
Sobieraj, T.
Powiązania:
https://bibliotekanauki.pl/articles/1368427.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
mikrokontroler z rdzeniem ARM
układ programowalny FPGA
falownik tranzystorowy
modulacja wektorowa
silnik synchroniczny z magnesami trwałymi
ARM microcontroller
field programmable gate array (FPGA)
transistor inverter
vector modulation
PMSM motor
Opis:
The paper presents a power converter designed in the Institute of Automatic Control Lodz University of Technology intended for laboratory tests PMSM motors. The main feature of the presented device is the ability to flexibly configure the control unit that contains both the ARM microcontroller core and the reconfigurable FPGA system. Thanks to this solution one has possibility of testing the drive control algorithms intended for use in both the sequential circuits (MCUs), as well as programmable circuits (FPGA). Advantage is the possibility of synergistic implementation of the algorithm, the division between the two currently most widely used computing architectures. Describes the specially designed true output voltage measurement system. This proprietary solution allows not only to reduce the demands on the performance of analog components used in the construction of the measuring circuit, but also significantly relieve the unit of account by the control system. The paper contains a discussion of the assumptions and algorithms design performance. It also provides selected waveforms in typical operating conditions of the system.
W artykule przedstawiono wektorowy falownik napięciowy zaprojektowany w Instytucie Automatyki Politechniki Łódzkiej przeznaczony do badań laboratoryjnych silników synchronicznych z magnesami trwałymi. Główną cechą prezentowanego urządzenia jest możliwość elastycznej konfiguracji jednostki sterującej wyposażonej zarówno w mikrokontroler z rdzeniem ARM, jak również układ rekonfigurowalny FPGA. Dzięki takiemu rozwiązaniu uzyskano możliwość testowania algorytmów sterowania implementowanych zarówno w układach sekwencyjnych (mikrokontrolery), jak również w układach programowalnych (FPGA). Zaletą urządzenia jest możliwość synergicznego podziału realizacji algorytmu pomiędzy te dwie obecnie najpowszechniej wykorzystywane architektury obliczeniowe. Opisano specjalnie zaprojektowany układ pomiarowy napięcia wyjściowego falownika. To autorskie rozwiązanie pozwala nie tylko zmniejszyć wymagania co do parametrów podzespołów analogowych użytych do budowy toru pomiarowego, ale również w znaczący sposób odciążyć jednostkę obliczeniową układu sterującego. W artykule omówiono przyjęte założenia projektowe oraz algorytmy działania urządzenia. Zamieszczono również wybrane przebiegi w charakterystycznych stanach pracy układu.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 179-183
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using the real-time simulator for prototyping power electronics inverter
Autorzy:
Baszynski, M.
Szlosek, M.
Powiązania:
https://bibliotekanauki.pl/articles/140638.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
numerical simulation
rectifiers
active filters
Real time systems
Opis:
This paper deals with real-time (RT) simulators applied in power electronic applications and implemented in a real inverter. The process of preparing and starting up an active rectifier prototype (with an active filter function), using the real-time OPAL RT simulator is given. The control system of the converter and the results of simulation using the Matlab/Simulink suite are discussed.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 447--460
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power injection control system and experimental model based on manufacturer characteristic curves for a photovoltaic generation system
Autorzy:
Rico, A.
Cadaval, E. R.
Montero, M. I. M.
Powiązania:
https://bibliotekanauki.pl/articles/262582.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
Inverter Current Controller (ICC)
Inverter Reference Current Generator (ICRG)
maximum power point tracking (MPPT)
Photovoltaic Cell (PV Cell)
PV Voltage and PV Current
VI characteristic equations
Opis:
This paper attempts to validate the performance of a power injection control block for Photovoltaic Generation Systems (PVGS). This device uses a control module based on detecting the power injected into the supply by the inverter, instead of measuring the power generated by the PVGS. The performance is evaluated using the concept of Maximum Energy Curve that takes into account both transient and permanent control performance. The paper presents a basic and simple procedure to obtain a model from the manufacturer characteristic curves of the photovoltaic cells. MATLAB Simulink is used as simulation tool to obtain the response of the proposed system to changes in temperature and irradiance.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 69-75
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stabilność pracy silnika indukcyjnego zasilanego z falownika napięcia
Stability of inverter fed induction motor
Autorzy:
Witkowska, A.
Adamowicz, M.
Witkowski, S.
Guziński, J.
Powiązania:
https://bibliotekanauki.pl/articles/268446.pdf
Data publikacji:
2003
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Opis:
W artykule zamieszczono wstępne wyniki badań analizy stabilności silnika indukcyjnego zasilanego z falownika napięcia. Przedstawiono model matematyczny silnika indukcyjnego oraz określono warunki pracy układu przyjmując założenia dla wyznaczenia równań opisujących pracę układu napędowego w stanie ustalonym. Określono transmitancję silnika indukcyjnego w celu wyznaczenia zakresu jego stabilnej pracy. Wykazano możliwość wystąpienia niestabilnej pracy układu z silnikiem indukcyjnym zasilanym z falownika napięcia.
The preliminary results of stability analysis of control system for inverter fed induction motor are presented. The mathematical model of induction motor is presented as well as working conditions of the system are defined with steady state assumption for electric drive equations. The transmittance of induction motor was determined to specify the stability range. Possibility of instability of control system for inverter fed induction motor is proofed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2003, 19; 151-156
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review and comparison of methods for limiting leakage currents in single-phase transformerless PV inverter topologies
Autorzy:
Kołodziejski, Wojciech
Jasielski, Jacek
Kuta, Stanisław W.
Szerszeń, Grzegorz
Machowski, Witold
Powiązania:
https://bibliotekanauki.pl/articles/29521110.pdf
Data publikacji:
2022
Wydawca:
Akademia Tarnowska
Tematy:
Differential Mode (DM) voltage
Common Mode (CM) voltage
grid-tied inverter
leakage current
parasitic capacity
photovoltaic (PV) systems
transformerless inverter
napięcie trybu różnicowego (DM).
napięcie trybu wspólnego (CM).
falownik podłączony do sieci
prąd upływowy
pojemność pasożytnicza
systemy fotowoltaiczne (PV).
falownik beztransformatorowy
Opis:
Transformerless inverters are widely used in different photovoltaic nonisolated ac module applications, mainly in grid-tied photovoltaic (PV) generation systems, due to the benefits of achieving high efficiency over a wide load range, and low cost. Various transformerless inverter topologies have been proposed to meet the safety requirement of low ground leakage currents, such as specified in the VDE-4105 standard and low-output ac-current distortion. Topology modifications of transformerless full bridge inverters are designed to balance and maintain a constant common mode output voltage, thereby eliminating or reducing leakage currents. This article reviews and compares the different methods for limiting leakage currents in known topologies of the full-bridge transformerless inverters, such as: H4, H5, H6, HERIC, and their improvements. The main topologies and strategies used to reduce the leakage current in transformerless schemes are summarized, highlighting advantages and disadvantages and establishing points of comparison with similar topologies. To compare the properties of different medium to high power inverters, PV inverter topologies were implemented using IGBTs and tested with the same components, same simulation parameters in PSPICE to evaluate their performance in terms of energy efficiency and leakage current characteristics. The detailed power stage operating principles, extended PWM modulator, and integrated universal gate driver with galvanic isolation in the transmission path of control signal for all IGBTs of the inverter, as well isolated and floating bias power supply for gate drivers are described.
Źródło:
Science, Technology and Innovation; 2022, 16, 3-4; 1-19
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A wide-band power electronics current source in reference current generator
Autorzy:
Gwóźdź, M.
Powiązania:
https://bibliotekanauki.pl/articles/97463.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
control algorithm
DSP
inverter
PWM
stability of an electrical system
Opis:
The paper considers wide-band voltage controlled power electronics current source. The current source has been designed as a part of 1-channel reference current generator designed for current meters testing. The control module of the generator utilizes a specialized Analog Devices Inc. DSPs based microcomputer module for power electronics applications. Used solutions have allowed obtain high quality referencing of the output current within reference signal. The paper presents the structure and selected aspects of the control algorithm of the current source. Also selected investigations results of the laboratory prototype of generator are presented.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 252-257
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pasywna stabilizacja rozkładu napięć w obwodzie pośredniczącym falownika trójpoziomowego NPC
Passive control of the DC-link midpoint voltage in the three-level NPC inverter
Autorzy:
Szczepankowski, P.
Nieznański, J.
Powiązania:
https://bibliotekanauki.pl/articles/154083.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
falownik trójpoziomowy
modulacja szerokości impulsów
pasywna stabilizacja napięcia punktu środkowego
three-level NPC inverter
pulse width modulation (PWM)
passive control of the DC-link midpoint voltage
Opis:
Przedstawiono wyniki badań dotyczące pasywnej stabilizacji rozkładu napięć w obwodzie pośredniczącym falownika trójpoziomowego NPC wskazujące na dobre uwarunkowania tej metody i możliwość jej wykorzystania w zastosowaniach praktycznych. Odpowiednio skonstruowana stabilizacja pasywna zapewnia stateczną pracę z podtrzymywaniem równowagi napięć i powrót napięcia niezrównoważenia do zerowej wartości średniej po ewentualnym zaburzeniu tej równowagi.
The paper presents and discusses some test results pertaining to the passive control of the DC-link midpoint voltage in the three-level NPC inverter. The results indicate that the method is well-behaved, insuring stable operation with balanced voltages across both capacitors in the DC link, convergence to a voltage balance after possible disturbances and low sensitivity to asymmetries in the inverter load.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 44-47
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal Switching Sequence – Model Predictive Flux Control of Three-Level Inverter-Fed Induction Motor Drive
Sterowanie predykcyjne z optymalną sekwencją łączeń falownika trójpoziomowego zasilającego napęd z silnikiem indukcyjnym klatkowym
Autorzy:
Stando, D.
Kaźmierkowski, M. P.
Powiązania:
https://bibliotekanauki.pl/articles/160221.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
Sterowanie predykcyjne z modelem
Napędy silników indukcyjnych
falowniki trójpoziomowe NPC
Model predictive control
Induction motor drives
three-level NPC inverter
Opis:
W artykule przedstawiono nowatorski system predykcyjnego sterowania z modelem (ang. Model Predictive Control – MPC) bez-czujnikowym napędem z silnikiem klatkowym zasilanym z falownika trójpoziomowego pracującego w szerokim zakresie prędkości łącznie z osłabianiem strumienia stojana. Do ważnych zalet opracowanego układu sterowania napędu należą: bardzo wysoka dynamika regulacji momentu i strumienia, stała częstotliwość łączeń falownika i brak konieczności doboru współczynników wag w funkcji kosztów sterowania predykcyjnego. Opisano zasady teoretyczne zastosowanej optymalnej sekwencji łączeń w metodzie sterowania predykcyjnego. Przedstawione wyniki eksperymentalne napędu o mocy 50 kW potwierdzają zalety zaproponowanego systemu sterowania predykcyjnego.
The paper presents a novel model predictive torque control scheme for three-level inverter-fed sensorless induction motor drive operated in wide speed region including field weakening. Among the important features of the developed drive are: very high dynamics, constant switching frequency and no need to adjust weighting factors in the cost function. The theoretical principles of the used optimal switching sequence predictive control methods are discussed. The experimental results measured on 50 kW drive validate performances of the proposed predictive control system.
Źródło:
Prace Instytutu Elektrotechniki; 2018, 280; 25-38
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault tolerant control of a PMSM drive in the selected emergency conditions
Autorzy:
Siembab, K.
Powiązania:
https://bibliotekanauki.pl/articles/376452.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
PMSM
PMSM drive
fault-tolerant inverter
FTC
Fault Tolerant Control
Opis:
The paper describes an investigation of fault tolerant control strategies for permanent magnet synchronous motor (PMSM) driven by a fault-tolerant inverter. The inverter is a topology-modified inverter with fault-tolerant capability, which can be configured as the standard 3-phase 6-switch inverter and reconfigured as 3-phase 4-switch or 2-phase 4-switch inverter under the fault condition. By analyzing operating principle of a fault-tolerant inverter and the mathematical model of PMSM, fault tolerant control algorithms are investigated. There is a conclusion that three phase stator windings of PMSM can be effectively operated by controlling only two phase currents. Simulation results show the validity of the proposed methods.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 75; 165-172
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repetitive neurocontroller with disturbance feedforward path active in the pass-to-pass direction for a VSI inverter with an output LC filter
Autorzy:
Ufnalski, B.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/200017.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
repetitive control
feedforward neural network
dynamic optimization problem
repetitive disturbance rejection
voltage source inverter
disturbance dual feedforward path
sterowanie powtarzalne
sieci neuronowe
problem optymalizacji dynamicznej
przetwornica napięcia
odrzucanie zakłóceń
Opis:
An enhancement to the previously developed repetitive neurocontroller (RNC) is discussed and investigated in the paper. Originally, the time-base generator (TBG) has been used to produce the only input signal for the neural approximator. The resulting search space makes the dynamic optimization problem (DOP) of shaping the control signal solvable with the help of a function approximator such as the feed-forward neural network (FFNN). The plant under consideration, i.e. a constant-amplitude constant-frequency voltage-source inverter (CACF VSI) with an output LC filter, is assumed to be equipped with the disturbance load current sensor to enable implementation of the disturbance feed-forward (pDFF) path as a part of the non-repetitive subsystem acting in the along the pass p-direction. An investigation has been undertaken to explore potential benefits of using this signal also as an additional input for the RNC to augment the approximation space and potentially enhance the convergence rate of the real-time search process. It is numerically demonstrated in the paper that the disturbance feed-forward path active in the pass-to-pass k-direction (kDFF) improves the dynamics of the repetitive part as well indeed.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 1; 115-125
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie dyskretnej transformaty falkowej do diagnostyki uszkodzeń falownika napięcia
An application of discrete wavelet transform for voltage source inverter fault diagnosis
Autorzy:
Śleszyński, W.
Nieznański, J.
Powiązania:
https://bibliotekanauki.pl/articles/268452.pdf
Data publikacji:
2003
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Opis:
W artykule przedstawiono nową metodę diagnostyki falownikowego układu napędowego z silnikiem indukcyjnym, umożliwiającą wykrywanie i identyfikację uszkodzeń falownika napięcia, polegających na braku przewodzenia jednego z łączników. Istotą metody jest monitorowanie poziomów sygnałów diagnostycznych w trzech fazach falownika. Sygnał diagnostyczny zdefiniowano jako iloraz sumy wartości maksymalnej i minimalnej współczynników aproksymacji jednopoziomowej transformaty falkowej prądu do różnicy tychże wartości. Współczynniki aproksymacji reprezentują składową wolnozmienną prądu, obliczenia na ich wartościach szczytowych wykonywane są tylko raz na okres podstawowej harmonicznej prądu falownika. Użycie tak skonstruowanych sygnałów diagnostycznych pozwala na zastosowanie stałych progów detekcji, niezależnie od punktu pracy napędu.
This paper describes a novel approach to the detection and localization of an open transistor faults in VSI-fed AC drives. For each phase current, one-stage discrete wavelet transform was performed. A sum and difference from the minimum and maximum values of approximation coefficients was calculated once within voltage fundamental period. The sum-to-difference ratio was used as the diagnostic variable. This choice allow simplifying the detection algorithm by introducing a constant detection threshold. The method has proved to reliably detect true faults, while not issuing false alarms under transient conditions. The method has been validated by simulation.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2003, 19; 133-138
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of 5 kW Converter Leg for Power Electronic System
Autorzy:
Zygmanowski, M.
Michalak, J.
Jeleń, M.
Jarek, G.
Powiązania:
https://bibliotekanauki.pl/articles/973060.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IGBT
Silicon Carbide (SiC)
MOSFET
Inverter
Microgrid
Opis:
Three converter leg variants are analyzed for low power converter used for power electronic system for residential buildings. The two-level Si-IGBT and SiC-MOSFET converters are compared with Si-IGBT three-level T-type converter. Power losses generated in each of these converters over a predicted period of 20 years of operation are contrasted with the cost of converter options. The detailed selection procedure for output inductor is presented in this paper. This procedure shows the influence of the inductor parameters like number of turns, air gap length on its losses, cost and size. Theoretical approach is verified with simulations and experimental results.
Źródło:
Measurement Automation Monitoring; 2017, 63, 8; 282-287
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Autonomiczna prądnica indukcyjna z kaskadowym falownikiem napięcia
Autonomous induction generator with cascaded voltage inverter
Autorzy:
Żarnowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1373089.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
prądnica indukcyjna
maszyna indukcyjna
falownik napięcia
autonomiczna prądnica indukcyjna
Opis:
In the paper a frequency and voltage stabilisation system of autonomous, self-excited induction generator (API) is presented. Electrical energy with uncontrolled parameters, produced by API is converted to sin wave output energy with constant frequency and voltage with the help of a cascade inverter. Output voltage stabilisation is performed in the DC intermediate circuit of the inverter. The control strategy and the way of adding voltages in the cascade inverter which allow to eliminate the most significant harmonics up to assumed harmonic number is defined. Simulation results are enclosed.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 86; 11-15
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of self-excited synchronous generator with inverter as DC grid voltage source
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/378011.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
self-excited generator
FOC control
DC grid
controlled voltage source
Opis:
Self-excited generators are the most popular voltage sources installed onboard of modern ships. Because of fuel savings on some specialized vessels (PSV, cable layers etc.) varying revolutions drives are used and this trend seems to increase. Very interesting issue is use of such type of alternator working with inverter acting as rectifier in DC grid system. As the control method most suitable to use is modified field oriented control known from induction machines. This control method involves decoupling of currents and control voltages to flux and torque components and keeping them in optimal (orthogonal) condition. Theoretical background of inverter and synchronous generator adopted FOC control method along with experimental results obtained in laboratory of such system were presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 95; 209-220
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane algorytmy diagnostyki układu napędowego z falownikami napięcia
Chosen inverter-fed motor drive diagnostic algorithms
Autorzy:
Sołbut, A.
Powiązania:
https://bibliotekanauki.pl/articles/1373079.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka układów napędowych
układ napędowy
falownik napięcia
algorytm diagnostyczny
Opis:
Present-day motor drives are using voltage inverters for motor speed controlling. Voltage inverters control systems are based on microprocessor technology. Microprocessors, that are used in inverters control systems can also be used for motor drives state estimation. Propositions of algorithms, that are possible to implement in motor drives control systems are presented in the paper. It's suggested to use moving RMS and average values of chosen signals available in control algorithms. Moving values calculation algorithm is presented in C++ language code, so it is possible to implement it in an own solutions. Propositions of algorithms are supported by simulations and laboratory tests results of a motor drive with Field Orientation Control method.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2010, 86; 35-40
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current limiting algorithm for three-phase grid-connected inverters
Autorzy:
Tran, Tho Quang
Powiązania:
https://bibliotekanauki.pl/articles/2135740.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current limitation
negative sequences
reactive power compensation
three-phase grid-connected inverter
unbalanced voltages
Opis:
Grid-connected inverters are commonly used in systems of renewable energy to convert this energy source into AC power with parameters suitable for connection to the grid. In the normal operating conditions, the grid-connected inverters mainly generate active power to the grid. However, when a voltage sag or voltage imbalance occurs, the grid voltage imbalance in the conventional control methods causes negative sequence components and increases the output current magnitude of inverters. The increase of current can damage power semiconductor devices. This paper presents a strategy to limit the current magnitude of inverters under unbalanced grid voltage conditions. In this strategy, a multiple-complex-coefficient filter is used to eliminate the negative sequence voltage components. This method does not require any additional hardware. A three-phase gridconnected photovoltaic inverter system using a solar array of 20 kWp is also used for the survey. The effectiveness has been validated when comparing the simulation results on Matlab/Simulink of the proposed method with those of the conventional method.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 559--579
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estymacja napięcia niezrównoważenia w obwodzie pośredniczącym falownika trójpoziomowego NPC na podstawie analizy prądów wyjściowych
Evaluation of the neutral-point voltage in the three-level NPC inverter based on analysis of output currents
Autorzy:
Szczepankowski, P.
Nieznański, J.
Powiązania:
https://bibliotekanauki.pl/articles/154081.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
trójpoziomowy falownik napięcia
modulacja szerokości impulsów
stabilizacja napięcia punktu środkowego
three-level NPC inverter
pulse width modulation (PWM)
control of the DC-link midpoint voltage
Opis:
Zaproponowano prostą i skuteczną metodę wyznaczania wartości napięcia niezrównoważenia w obwodzie pośredniczącym trójpoziomowego falownika NPC (ang. Neutral-Point-Clamped). Zastosowanie proponowanej metody nie wymaga dodatkowych czujników pomiarowych, a nakłady obliczeniowe na realizację algorytmu są niewielkie. Do wyznaczania napięcia niezrównoważenia wykorzystuje się informacje zawarte w mierzonych prądach wyjściowych falownika. Wymagana jest znajomość impedancji obciążenia. Przedstawiono wyniki badań symulacyjnych i laboratoryjnych potwierdzających prawidłowe działanie proponowanej metody.
A simple and effective method is proposed for evaluating the neutral-point voltage in the three-level neutral-point-clamped (NPC) inverter. The method does not require extra sensors, and the use of computing resources is limited. The neutral-point voltage is estimated based on the current measurements. The proposed approach necessitates the knowledge of the load impedance. Sample simulation and experimental results are provided, confirming satisfactory working of the proposed method.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 48-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies