This paper proposes a new dc-side active filter for wind generators that combines 12-pulse polygon auto-transformer rectifier with dc-side current injection method
and dual-buck full-bridge inverter having not the “shoot-through” problem in conventional
bridge-type inverters, and therefore this system with the character low harmonic distortion
and high reliability. The proposed dc-side active filter is realized by using dual-buck full
bridge converter, which directly injects compensation current at dc-side of two six-pulse
diode bridges rectifiers. Compared with the conventional three-phase active power filter at
ac-side, the system with the dc-side active filter draws nearly sinusoidal current by shaping
the diode bridges output current to be triangular without using the instantaneous reactive
power compensation technology, only using simple hysteretic current control, even though
under load variation and unbalanced voltage disturbances, and while an acceptable linear
approximation to the accurate waveform of injection current is recommended. The performance of the system was simulated using MATLAB/Simulink, and the possibility of the
dc-side active filter eliminating current harmonics was confirmed in steady and transient
states. The simulation results indicate, the system has a total harmonic distortion of current
reduced closely to 1%, and a high power factor on the wind generator side.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies