- Tytuł:
-
Application of membranes to treat natural and waste waters: new considerations to reduce fouling and increase recovery Up to 99%
Zastosowanie membran do oczyszczania wody i ścieków: nowe aspekty zmniejszenia zanieczyszczenia i zwiększenia odzysku do 99% - Autorzy:
-
Pervov, A.
Andrianov, A.
Gorbunova, T. - Powiązania:
- https://bibliotekanauki.pl/articles/400299.pdf
- Data publikacji:
- 2011
- Wydawca:
- Polskie Towarzystwo Inżynierii Ekologicznej
- Tematy:
-
ścieki bytowe
nanofiltracja
odwrócona osmoza
odzysk
regeneracja
domestic wastewater
fouling-free technologies
membrane fouling
nanofiltration
natural water treatment
open-channel module
reclamation
recovery
reverse osmosis
scaling
spiral wound module
urban surface water
zero discharge - Opis:
-
Survey shows that high operational costs of membrane facilities and large amounts of effluents are mainly attributed to fouling and scaling. Research of scaling and fouling mechanisms showed that these processes depend not only on hydraulic and hydrodynamic factors, but on membrane type, material and channel configuration as well. Operational parameters of different membrane configurations show that spiral wound modules demonstrate best hydraulic and hydrodynamic characteristics combined with lowest price. Main ways to develop new fouling-free techniques are outlined that require modified "open-chan-nel" spiral wound membranes. Elimination of "deadlocks" as a main cause of scaling and fouling provide new technological approach to develop water treatment techniques without pretreatment facilities and chemicals. Modification of channel provides possibility to reach high recoveries and high supersaturation values due to strong stability of calcium carbonate solutions. Membrane transport is not only purification instrument it is also a reactor to coagulate, concentrate and precipitate water constituents on membrane surface. Several examples of water treatment flow diagrams are presented to demonstrate principles of zero concentrate flow discharge. Coagulated suspended matter after membrane flushes is collected, sedimented and finally dewatered. The dewatered sludge contains averagely 0,8 per cent of initial water. Due to the use of an "open-channel" modules membrane brine flow could be concentrated by many times without a fear of scaling and added to the sludge. Thus the excessive salts and impurities could be withdrawn from water systems together with partially dewatered sludge. Similarly excessive calcium carbonate could be also concentrated in membrane modules and subsequently precipitated, sedimented and dewatered. Solution of fouling problems thus provides a new approach to save operational costs and to increase ecological efficiency of membrane water treatment tools.
Badania wykazują, iż wysokie koszty eksploatacji urządzeń z zastosowaniem membran i duże ilości odcieków są przypisywane zanieczyszczeniom i odkładaniu się kamienia. Procesy te zależą nie tylko od czynników hydraulicznych i hydrodynamicznych, ale także od rodzaju membran i materiałów użytych do ich budowy. Parametry pracy różnych membran wykazały najlepsze właściwości modułów spiralnych przy najniższej cenie. Przepływ przez membrany nie ogranicza się jedynie do oczyszczania, jest to także reaktor do koagulacji, zatężania i strącania. Zawiesina po procesie koagulacji z procesu czyszczenia membran jest poddana sedymentacji i odwadnianiu. Osad z odwadniania zawiera około 8% wody. Zastosowanie modułów o "otwartych kanałach" powoduje zmniejszenie zagrożenia zanieczyszczenia i odkładania się kamienia. Rozwiązanie problemu zmniejszenia zanieczyszczenia membran pozwoli zmniejszyć koszty pracy instalacji i spowoduje wyższy poziom ekologicznej efektywności narzędzi wykorzystujących technikę membranową. - Źródło:
-
Inżynieria Ekologiczna; 2011, 24; 17-31
2081-139X
2392-0629 - Pojawia się w:
- Inżynieria Ekologiczna
- Dostawca treści:
- Biblioteka Nauki