Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transient overvoltage" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Study of transients in multiple power filter circuit comprising C-type filter
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/377600.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
C–type filter
single-tuned passive filter
switching transient
transient overvoltage
transient overcurrent
Opis:
Passive filters are widely used to mitigate the effect of load harmonics on the supply power grid. Topology selection of the filters is based on the frequency bandwidth to be suppressed. Filter topologies comprising single-tuned filters and damped filters are the most popular in industrial power system applications. The article focuses on the influence of the damped C-type 2nd harmonic filter on the transients behavior under arc transformer energization in the arc furnace power supply system compensated by SVC. The examination results of transient currents and voltages across capacitors and reactors of the 3rd and 5th passive filters are compared for two topologies of the SVC filter circuits: with and without C-type filter. The Matlab/Simulink Software was used to modeling filter behavior during unload transformer switching-on.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 95; 105-115
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients under energizing multiple power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97327.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
C–type filter
Static Var Compensator
transient overcurrent
transient overvoltage
dynamic overcurrent
dynamic overvoltage
switching transients
Opis:
The practice of operating reactive power compensation systems involving passive multiple filter circuits (FC) configured by single–tuned filters has shown, that it’s energizing can cause damage of the filter components. Impact of feasible FC configurations, including FC with a C–type filter, on switching overvoltages and overcurrents under the harmonic filters energizing were analyzed. Influence of the filters tuning on transient behavior has been shown. The transient analysis has been carried out by simulating of the FC within Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 89-100
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of transient overvoltages in high voltage gas insulated substations
Analiza przepięć szybkozmiennych w stacjach wysokiego napięcia izolowanych gazem SF6
Autorzy:
Kuczek, T.
Florkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/266478.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
odłącznik
operacje łączeniowe
przepięcia
stacja izolowana gazem SF6
switching
transient overvoltage
GIS
disconnector
Opis:
Gas Insulated Substations (GIS) are broadly used for transmission and distribution of electric power. Due to the interactions with a network and various environmental phenomena like lightning the GIS are subjected to the very fast transients (VFT). Such VFT can be also created within GIS mainly by the disconnector operations. Paper will present an approach towards modeling of transient phenomena in GIS. The equivalent parameters along with basic models considered in substation and high voltage network modeling will be described. The difference between low and high frequency modeling will be highlighted. The simulation of transients in exemplary high voltage substation will be shown.
Stacje izolowane gazem SF6 (GIS) są szeroko wykorzystywane w elektroenergetycznych systemach przesyłowych i dystrybucyjnych. W wyniku zjawisk przejściowych takich jak operacje łączeniowe oraz wyładowania atmosferyczne, stacje GIS narażone są na występowanie przepięć bardzo szybko zmiennych, tzw. Very Fast Transients (VFT). Przepięcia te mogą być również efektem operacji łączeniowych dokonywanych odłącznikiem. Artykuł przedstawi zasady modelowania zjawisk przejściowych w stacjach GIS. W pracy zostanie ponadto pokazana przykładowa analiza przepięć generowanych poprzez operowanie odłącznikiem w stacji GIS.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2011, 30; 77-80
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients impact on power filter circuit sizing
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97523.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
transient and dynamic overvoltage
transient and dynamic overcurrent
equipment ratings
Opis:
The practice of operating multiple single-tuned filters in AC electrical arc furnace power supply systems has shown, that frequent energizing unloaded furnace transformer can cause damage of the filters. To examination of supply and filter system configuration impact on switching transient and dynamic overvoltages and overcurrents, an example of 50 MVA arc furnace unit was chosen. The transient analysis has been carried out by simulating within Matlab/Simulink Software. Using ANSI/IEEE Standards paper focuses on the selections of ratings for capacitors and air-core reactors used in multiple single-tuned harmonic filters configurations. Comparison of filter reactor and capacitor bank design based on steady state operation and transformer energizing was shown.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 111-119
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling transients in MV resonantly grounded industrial grid during single line to ground faults
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/377060.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical grid
grounding methods
transients overvoltage
transient intermittent faults
Opis:
Medium voltage distribution power grids mostly operate with ungrounded neutral points of transformer. The philosophy about these power supply systems based on the assumption that the electrical grid is more reliable. However the practice of operation showed that currents of single phase or multiple faults to ground depend mostly on the earth capacitances of cables connected to power grid and configuration and structure in relation to the main substation buses. Moreover, this kind of arcing ground faults on the ungrounded system causes transient overvoltages several times than nominal value. In the consequence, it may be dangerous for the electrical devices connected to the power system. The article focuses on the transient impact the equipment insulation due to faults in the middle voltage industrial grid with adjustable speed drives. The examination results of transient voltages across the system was presented. The Matlab/ Simulink Software was used to modeling system behavior during intermittent faults.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 98; 65-75
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modifying the Transient Overvoltages in Mixed Power Networks by Inserting Cable Sections
Autorzy:
Saied, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/262837.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
cable
overvoltage
transformer
veutral treatment
transient model
lightning
mixed power networks
Opis:
The paper deals with the analysis of the electromagnetic transients in mixed power net-works. Special emphasis is made on assessing the effectiveness of using cable sections in reducing the transients in the power network components such as transformer substations. A distributed parameter modeling of the overhead lines, underground cables and transformer windings is applied in the Laplace domain. The simulation can handle the different time waveforms of the sources initiating the transients, the lengths of the cable sections as well as the transformers’ neutral treatment. The direct analytical s-domain solution is numerically inverted in order to get the corresponding time domain results. The affecting parameters such as the line and cable surge impedances, the length of the cable section (or its time delay) and the transformer data, are investigated. A case involving multiple-pulse lightning surges is also addressed. The results of four case studies of known solutions are presented in order to validate the developed mathematical model and computer program.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2015, 18, 1; 7-14
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies