Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "titration" wg kryterium: Temat


Wyświetlanie 1-32 z 32
Tytuł:
Assay of the Insensitive High Explosive 3-Nitro-1,2,4-triazol-5-one (NTO) by Acid-Base Titration
Autorzy:
Nandi, A. K.
Singh, S. K.
Kunjir, G. M.
Singh, J.
Mandal, A. K.
Pandey, R. K.
Powiązania:
https://bibliotekanauki.pl/articles/358351.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
NTO
purity
acid-base titration
HPLC
quality control
Opis:
The insensitive high explosive 3-nitro-1,2,4-triazol-5-one (NTO) is a weak acid (pKa 3.76) due to the labile N–H bond. The weakly acidic character of this compound is exploited for its assay by aqueous acid-base titration. The NTO sample was dissolved in water and the resultant solution was titrated against 0.07 N NaOH solution using phenolphthalein as indicator. Regular batch samples were assayed by this method and the results were compared with those obtained by the HPLC method. The aqueous acid-base titration method was found to be suitable for the quality control of the product.
Źródło:
Central European Journal of Energetic Materials; 2013, 10, 1; 113-122
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assay of the thermally stable, insensitive, high explosive 1,3,5-triamino-2,4,6-trinitrobenzene (TATB)
Autorzy:
Nandi, A. K.
Thirupathi, N.
Mandal, A. K.
Pandey, P. K.
Powiązania:
https://bibliotekanauki.pl/articles/358608.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
assay TATB
acid-base titration
base hydrolysis
trinitrophloroglucinol
ammonium chloride
Opis:
An aqueous titration method is described to assay the insensitive, high explosive 1,3,5-triamino-2,4,6-trinitrobenzene (TATB). TATB is initially quantitatively converted to the weak acid 1,3,5-trihydroxy-2,4,6-trinitrobenzene (THTNB) by base catalysed hydrolysis. Subsequently THTNB is assayed by acidbase titration. TATB samples obtained from regular batch operations are assayed by this method, and the results are compared with those obtained by the total amino functional group estimation method using a modified Kjeldhal apparatus. The method is simple and has good accuracy and precision.
Źródło:
Central European Journal of Energetic Materials; 2014, 11, 2; 295-305
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electron-transfer complexation of morpholine donor molecule with some π – acceptors: Synthesis and spectroscopic characterizations
Autorzy:
Al-Wasidi, Asma S.
Al-Jafshar, Nawal M.
Al-Anazi, Amal M.
Alosaimi, Eid H.
Refat, Moamen S.
El-Zayat, Lamia
Al-Omar, Mohamed A.
Naglah, Ahmed M.
El-Nour, K.M. Abou
Powiązania:
https://bibliotekanauki.pl/articles/778928.pdf
Data publikacji:
2019
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Morpholine
π-acceptor
CT complex
photometric titration
infrared
Benesi-Hildebrand
Opis:
Morpholine is an interesting moiety that used widely in several organic syntheses. The intermolecular charge-transfer (CT) complexity associated between morpholine (Morp) donor with (monoiodobromide “IBr”, 2,3-dichloro-5,6-dicyano-1,4-benzoquinone “DDQ”, 2,6-dichloroquinone-4-chloroimide “DCQ” and 2,6-dibromoquinone-4-chloroimide “DBQ”) π–acceptors have been spectrophotometrically investigated in CHCl3 and/or MeOH solvents. The structures of the intermolecular charge-transfer (CT) were elucidated by spectroscopic methods like, infrared spectroscopy. Also, different analyses techniques such as UV-Vis and elemental analyses were performed to characterize the four morpholine [(Morp)(IBr)], [(Morp)(DDQ)], [(Morp)(DCQ)] and [(Morp)(DBQ)] CT-complexes which reveals that the stoichiometry of the reactions is 1:1. The modified Benesi-Hildebrand equation was utilized to determine the physical spectroscopic parameters such as association constant (K) and the molar extinction coefficient (ε).
Źródło:
Polish Journal of Chemical Technology; 2019, 21, 4; 82-88
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ilościowe oznaczanie dodecylosiarczanu sodu zmodyfikowaną metodą miareczkowania fotometrycznego
The quantitative determination of sodium dodecyl sulphate by modified photometric titration method
Autorzy:
Hernet, Julia
Powiązania:
https://bibliotekanauki.pl/articles/2055881.pdf
Data publikacji:
2019
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
dodecylosiarczan sodu
titrant
miareczkowanie fotometryczne
anionic surfactant
SDS
titration
titrimetric method
Opis:
Znana procedura wyznaczania krzywych wzorcowych do ilościowego oznaczania dodecylosiarczanu sodu (SDS) wykorzystuje powolne miareczkowanie roztworów SDS błękitem toluidynowym do momentu osiągnięcia zdefiniowanej wartości absorbancji. Podstawą proponowanej zmodyfikowanej metody wyznaczania krzywych wzorcowych jest wprowadzenie do roztworu analitu dawki titranta i pomiar absorbancji. Modyfikacja ta ma skrócić czas analizy surfaktanta. Surfaktanty należą do grupy związków chemicznych szeroko stosowanych do produkcji środków czystości i kosmetyków, a także środków chemicznych stosowanych w przemyśle spożywczym, maszynowym i motoryzacyjnym. Celem badań było wyznaczanie krzywych wzorcowych do oznaczania SDS wg standardowej oraz zmodyfikowanej procedury miareczkowej i porównanie oraz analiza uzyskanych wyników.
The aim of this thesis was to develop a modified method for photometric determination of anionic surfactant (SDS) as well as to compare this new method with the standard procedure. In the practical part presented are results of the analysis of the photometric titration curves obtained in the system: surfactant – thiazine dye. The modified method of surfactant determination consists of introducing into the analyte solution a large dose of the dye, measuring the absorbance and reading the concentration from the calibration curve. Such procedure accelerates considerably the quantitative determination of SDS while maintaining the accuracy characteristic of the standard titrimetric method.
Źródło:
Postępy w Inżynierii Mechanicznej; 2019, nr 13(7); 13--23
2300-3383
Pojawia się w:
Postępy w Inżynierii Mechanicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of tramadol hydrochloride and its preparations by acid-base titration in non-aqueous medium
Autorzy:
Vinay, K.B.
Revanasiddappa, H.D.
Rajendraprasad, N.
Raghu, M.S.
Ramesh, P.J.
Xavier, C.M.
Basavaiah, K.
Powiązania:
https://bibliotekanauki.pl/articles/3614.pdf
Data publikacji:
2010
Wydawca:
Instytut Medycyny Wsi
Tematy:
determination
tramadol hydrochloride
preparation
acid-base titration
non-aquatic medium
titrimetry
Źródło:
Journal of Pre-Clinical and Clinical Research; 2010, 04, 1
1898-2395
Pojawia się w:
Journal of Pre-Clinical and Clinical Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja warunków oznaczania wody metodą miareczkowania kulometrycznego z odparowaniem dla olejów smarowych
Optimization of the water determination conditions by coulometric titration with evaporation for lubricating oils
Autorzy:
Jędrychowska, Sylwia
Powiązania:
https://bibliotekanauki.pl/articles/2143634.pdf
Data publikacji:
2021
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
woda
miareczkowanie kulometryczne
KF
odparowanie
oleje smarowe
water
coulometric titration
evaporation
lubricating oils
Opis:
Wiedza o zawartości wody w produktach naftowych, między innymi olejach smarowych, dodatkach oraz różnych innowacyjnych produktach, jest istotna z punktu widzenia ich wytwarzania, zakupu czy sprzedaży ze względu na wpływ na ich jakość i charakterystykę działania. W przypadku olejów smarowych obecność wody może stanowić przyczynę przedwczesnej korozji i zużycia, powstawania osadów, co prowadzi do ograniczenia smarowania i przedwczesnego zatkania filtrów, osłabienia działania dodatków czy niepożądanego wzrostu bakterii. W artykule przedstawiono prace nad dobraniem optymalnych warunków oznaczania zawartości wody metodą miareczkowania kulometrycznego Karla Fischera z odparowaniem w olejach smarowych. Badania przeprowadzono z wykorzystaniem kulometru z celą miareczkową bez diafragmy firmy Metrohm model 917 Coulometer wraz automatycznym podajnikiem próbek wyposażonym w komorę grzejną 885 Compact Oven Sample Changer. Do badań wytypowano różne rodzaje olejów smarowych, a mianowicie oleje silnikowe o różnej klasie lepkości (5W-40, 10W-40, 15W-40, 5W-30), olej przekładniowy, olej hydrauliczny, olej turbinowy, olej bazowy oraz płyn hydrauliczny. Wszystkie wytypowane próbki olejów smarowych badano w czterech różnych warunkach pomiarowych: 110°C i 20 ml/min; 150°C i 50 ml/min, 180°C i 50 ml/min oraz 150°C i 70 ml/min. Stwierdzono, że w przypadku wszystkich wyżej wymienionych olejów smarowych najlepsze wyniki uzyskano przy ustawieniu temperatury pieca na 150°C i przy przepływie gazu nośnego wynoszącym 50 ml/min lub 70 ml/min. Określono wpływ różnych czynników, takich jak naważka próbki, temperatura pieca, prędkość przepływu gazu nośnego, na przebieg badania oraz szybkość analizy. Zwiększony przepływ gazu nośnego do 70 ml/min nie powoduje skrócenia czasu analizy. W niektórych przypadkach wzrost temperatury pieca może przyspieszyć szybkość analizy, ale jest to dość ryzykowne dla niektórych próbek, które w tej temperaturze ulegają rozkładowi. W związku z tym bezpieczniej jest prowadzić badanie w temperaturze pieca 150°C. Największy wpływ na szybkość analizy ma odpowiedni dobór naważki próbki poddanej analizie. W zależności od zawartości wody w badanej próbce należy dobrać odpowiednią naważkę próbki. Powinna być ona na tyle mała, aby nadmiernie nie wydłużać analizy, ale także na tyle duża, żeby ilość odmiareczkowanej wody była przynajmniej dwukrotnie większa niż w ślepej próbie.
The knowledge of the water content of various petroleum products, including lubricating oils, additives and various innovative products, is important from the point of view of manufacturing, purchasing or selling them, due to the impact on their quality and performance characteristics. In the case of lubricating oils, the presence of water can lead to premature corrosion and wear, the formation of deposits, which leads to reduced lubrication and premature clogging of filters, reduced action of additives or undesirable bacterial growth. The article presents the study on the selection of optimal conditions for the determination of water content by coulometric Karl-Fischer titration with evaporation in lubricating oils. The tests were carried out using a coulometer with a titration cell without a diaphragm by Metrohm, 917 Coulometer model with an automatic sample feeder equipped with a heating chamber 885 Compact Oven Sample Changer. Various types of lubricating oils were selected for testing, namely engine oils of different viscosity classes (5W/40, 10W/40, 15W/40, 5W/30), gear oil, hydraulic oil, turbine oil, base oil and hydraulic fluid. All selected samples of lubricating oils were tested in four different measuring conditions: 110°C and 20 ml/min; 150°C and 50 ml/min, 180°C and 50 ml/min and 150°C and 70 ml/min. It was found that for all the lubricating oils, the best results were obtained with a furnace temperature setting of 150°C and a carrier gas flow of 50 ml/min or 70 ml/min. The influence of various factors, such as the sample weight, the furnace temperature, the carrier gas flow velocity on the test course and the analysis speed, was determined. Increased carrier gas flow of up to 70 ml/min does not shorten the analysis time. In some cases, an increase in the oven temperature may speed up the analysis, but this is quite risky for some samples that decompose at given temperature. It is therefore safer to conduct the test at an oven temperature of 150°C. The speed of analysis is most influenced by an appropriate selection of the sample quantity under analysis. Depending on the water content in the tested sample, the appropriate sample weight should be selected. It should be small enough not to excessively extend the analysis, but also large enough that the amount of titrated water is at least twice as large as in the blank.
Źródło:
Nafta-Gaz; 2021, 77, 7; 480-489
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probing of Cu2+ ions binding to A β (5−16) peptide using ITC measurements and MD simulations
Autorzy:
Makowska, J.
Żmudzińska, W.
Wyrzykowski, D.
Brzozowski, K.
Zblewska, H.
Chmurzyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/1938620.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska
Tematy:
A β (5 − 16) fragments
metal-peptide binding
isothermal titration calorimetry
molecular dynamics simulations
Opis:
It is shown that probably three residues: His6, His14 and His16 in the original sequence A β (1−42) serve as metal-binding sites for Cu2+ions. On the other hand, there is a possibility that only one of them plays a crucial role in the formation of the{A β (1-42)-Cu2+} complex. The isothermal titration calorimetry (ITC) measurements supported by molecular dynamic simulation (MD) with the NMR-derived restrains were used to investigate the interactions of Cu2+ with A β(5-16), a fragment of the A β(1-42) protein, with the following sequence: Ac-Arg-His-Asp-Ser-Gly-Tyr-Glu-Val-His-His-Gln-Lys-NH2, termed HZ1. The conditional thermodynamic parameters suggest that the formation of the Cu2+-HZ1 complex is both an enthalpy and entropy driven process under the experimental conditions. The studies presented here (after comparison with our previous results) show that the affinity of peptides to copper metal ions depends on two factors: the primary structure (amino acid composition) and the shape of the peptide conformation adopted.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2016, 20, 4; 409-416
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie chromatografii jonowej do oznaczenia zawartości chloru w biomasie stałej przeznaczonej do celów energetycznych
Application of ion chromatography for determination of chlorine content in solid biomass for power sector
Autorzy:
Zapała, E.
Kuklis, I.
Fabjańska-Świeca, G.
Tarnowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/1207471.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
chlor
biomasa energetyczna
chromatografia jonowa
miareczkowanie potencjometryczne
chlorine
energy crops
ion chromatography
potentiometric titration
Opis:
Jednym z parametrów decydujących o możliwości zastosowania określonego typu biomasy w termochemicznych procesach konwersji biomasy jest zawartość chloru. Pierwiastek ten, wraz z azotem i siarką, stanowi główne źródło związków kwaśnych, odpowiedzialnych za korozję aparatury oraz skażenie środowiska. Do oznaczania zawartości chloru w biomasie stosuje się wiele metod analitycznych. Między innymi są to metody miareczkowe, spektrometryczne, chromatograficzne, fluorescencji rentgenowskiej oraz wysokotemperaturowego utleniającego spalania z detekcją elektrochemiczną. Przedmiotem pracy było przeprowadzenie badań mających na celu oznaczenie zawartości chloru w próbkach biomasy, w tym przeznaczonych do celów energetycznych z wykorzystaniem chromatografii jonowej. Jednocześnie dokonano porównania uzyskanych wyników z zawartością chloru oznaczoną metodą miareczkowania potencjometrycznego z wykorzystaniem automatycznego titratora. Przeprowadzone testy statystyczne wykazały różnice pod względem precyzji i dokładności porównywanych metod. Większą dokładność wykazuje metoda chromatografii jonowej. Na podstawie wyliczonej wartości statystyki testu F-Snedecora stwierdzono, że metoda miareczkowa jest mniej precyzyjna niż chromatograficzna.
One of the crucial parameters deciding whether give type of biomass might be used in thermo-chemical conversion is chlorine content. This element, together with nitrogen and sulphur, is a main source of acidic compounds causing corrosion of installations and environmental pollution. Many different analytical methods are used for determination of chlorine content in biomass, including titration, spectrometry, chromatography, X-Ray fluorescence (XRF) and high-temperature oxidizing combustion with electrochemical detection. The scope of this study is the determination of chlorine content using ion chromatography in biomass samples, including those used in power industry. At the same time obtained results were compared with chlorine contents determined by means of potentiometric titration with use of automatic titrator. The statistical analysis shows differences in accuracy and precision of compared methods. Ion chromatography method shows greater accuracy, while calculated values of Snedecor’s F-test show that the titration method has smaller precision than chromatography method.
Źródło:
Chemik; 2013, 67, 12; 1217-1226
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the Electrolyte Type on the Adsorption and Electrokinetic Properties of the Ionic Polyamino Acids – Cr2O3 system
Autorzy:
Ostolska, Iwona
Wiśniewska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/951402.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
Polyamino acid
polyaspartic acid
polylysine
chromium (III) oxide
polymer adsorption
potentiometric titration
zeta potential
Opis:
The influence of a kind of support electrolyte on the ionic polyamino acids adsorption at the chromium (III) oxide – polymer solution interface was investigated. The NaCl and CaCl2 were used as the background electrolytes. In order to determine the effect of the electrolyte, the same value of ionic strength of the test solutions were taken. It was proved that formation of intermolecular and intramolecular complexes in the presence of divalent calcium ions is responsible for essential changes in polymer adsorption. Related to the ionic character of polyamino acid two different adsorption behaviours can be observed. The increase of the ASP adsorption amount in the presence of calcium ions may be explained by formation of complexes between the dissociated carboxylic groups and Ca2+ ions. The opposite situation takes place in the case of polylysine – the application of CaCl2 results in the dramatic decrease in the polymer adsorption caused by blocking the active sites available for LYS macromolecules. In order to make a comprehensive analysis, the zeta potential and surface charge density measurements were performed taking into account the kind of the background electrolyte. The above-mentioned tests were carried out in the absence and presence of the polyamino acid at two different concentrations – 10 and 100 ppm respectively.
Źródło:
Annales Universitatis Mariae Curie-Skłodowska, sectio AA – Chemia; 2013, 68, 1-2
2083-358X
Pojawia się w:
Annales Universitatis Mariae Curie-Skłodowska, sectio AA – Chemia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Measurement System of Hydrated Sodium Silicate Composition Analysis
Autorzy:
Wang, Huafang
Wang, Quanrun
Zhang, Wu
Gao, Xiang
Lu, Jijun
Powiązania:
https://bibliotekanauki.pl/articles/1837674.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hydrated sodium silicate
composition analysis
potentiometr
titration
uwodniony krzemian sodu
analiza składu
potencjometr
miareczkowanie
Opis:
Sodium silicate is one of the most successful inorganic binder. Along with the broad application of sodium silicate for domestic and industrial purposes, the composition analysis, include modulus (m), ratio of SiO2:Na2O, Na2O%, SiO2%, and solid-containing content, is important for the products strength and service life. However, it is perplexing to operate, inefficient and low precision for traditional standard testing method of these parameters. In this study, an automatic measurement system of sodium silicate composition analysis, with the potential electrode for potentiometer titration, micro-controller, PCB, heater, stirrer, printer and micro peristaltic pump, was developed according to the determine method principle. The end-points of pH value in the two titrating steps, first was 4.3 and second was 6.0, were set in the micro-controller to control the reaction in the processing of the sodium silicate composition analysis. And all the potential signals of the pH electrode were transited in the special PCB for the micro-controller.
Źródło:
Archives of Foundry Engineering; 2021, 21, 2; 5-8
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assay of the Insensitive High Explosive FOX-7 by Non-Aqueous Titration
Autorzy:
Nandi, A. K.
Paramasivan, P.
Singh, S. K.
Mandal, A. K.
Pandey, R. K.
Powiązania:
https://bibliotekanauki.pl/articles/358156.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
1,1-diamino-2,2-dinitroethene
FOX-7
non-aqueous titration
N,N-dimethylformamide
Opis:
A non-aqueous titration method was developed to assay the insensitive high explosive 1,1-diamino-2, 2-dinitroethene (FOX-7). The weak acidic nature of FOX-7 (pKa 10.6) was exploited in the assay method. The sample was dissolved in the protophilic solvent N, N-dimethylformamide and titrated against sodium methoxide solution in benzene/methanol using azo violet as indicator. FOX-7 samples obtained from regular batch operations were assayed by this method and the results were compared with that of a recrystallized sample. The method is simple, rapid and has good accuracy and precision.
Źródło:
Central European Journal of Energetic Materials; 2012, 9, 4; 343-352
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A quick method to determine the content of sulfates in silicic and aluminosilicate fillers
Autorzy:
Sołtysik, B.
Powiązania:
https://bibliotekanauki.pl/articles/778499.pdf
Data publikacji:
2007
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
siarczany
miareczkowanie potencjometryczne
napełniacze krzemionkowe
napełniacze glinokrzemianowe
sulfates
potentiometric titration
silicic fillers
aluminosilicate fillers
Opis:
The paper presents the possibility of using barium-selective electrode to a potentiometric determination of sulfates in silicic and aluminosilicate fillers. The results of sulfates potentiometric titration in silicic and aluminosilicate fillers are described. A statistical interpretation of the results was carried out. The recommended method is based on the end-point detection of sulfates potentiometric titration in hydro-alcoholic medium by means of barium chlorate(VII) titrant. The potentiometric titration, which uses an ion-selective electrode as the indicator for the end-point was applied as the analytical technique. The parameter ranges for accurate sulfates determination in model solutions and the method of samples' preparation for analysis were investigated.
Źródło:
Polish Journal of Chemical Technology; 2007, 9, 1; 33-35
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie wilgoci w biomasie metodą miareczkowania kulometrycznego Karla Fischera
Determination of moisture in biomass by coulometric Karl Fischer titration
Autorzy:
Jędrychowska, Sylwia
Kowalczyk, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2143254.pdf
Data publikacji:
2022
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
biomasa
woda
wilgoć
miareczkowanie kulometryczne
Karl Fischer
odparowanie
biomass
water
moisture
coulometry
titration
evaporation
Opis:
W artykule przedstawiono prace nad wykorzystaniem metody miareczkowania kulometrycznego Karla Fischera z odparowaniem do oznaczania zawartości wody w biomasie. Przeprowadzono badania sześciu rodzajów próbek biomasy roślinnej: zmielonej kawy otrzymanej jako odpad po zaparzeniu, słomy pszenicznej, siana, łupin orzecha włoskiego oraz zrębków drewna leszczynowego i świerkowego. Wykonano badania zawartości wody we wszystkich pozyskanych produktach i porównano wyniki z wynikami otrzymanymi dwiema innymi metodami stosowanymi standardowo do badania wilgoci w biomasie, tj. metodą wagosuszarkową i destylacyjną. Stwierdzono, że wszystkie metody wykazały dobrą zgodność w zakresie wyników uzyskanych dla przebadanych próbek. Najmniej przydatna okazała się metoda destylacyjna, której rezultaty najbardziej odbiegały względem pozostałych metod. Wykonanie analizy tą techniką wymaga długiego czasu, jest ona dość pracochłonna i niezautomatyzowana. Najszybszą techniką jest metoda wagosuszarkowa, ale cechuje ją mniejsza precyzja w stosunku do metody kulometrycznej. Wyniki otrzymane tą metodą mogą być zawyżone ze względu na to, że miarą zawartości wody w badanej próbce jest ubytek masy, który może być związany nie tylko z obecnością wody, ale także z innymi lotnymi substancjami uwalnianymi w trakcie badania. Metoda miareczkowania kulometrycznego Karla Fischera jest natomiast metodą selektywną i podczas analizy oznaczana jest tylko woda odparowywana z próbki, nawet gdyby z próbki uwalniały się jeszcze inne substancje lotne w warunkach badania. Metoda miareczkowania kulometrycznego Karla Fischera z odparowaniem próbki w piecyku wykazała się największą precyzją. Jest łatwa w wykonaniu i zautomatyzowana. Stwierdzono, że metoda ta może być z powodzeniem stosowana w badaniu biomasy. Zawartość wody we wszystkich pozyskanych próbkach biomasy wahała się w przedziale od 8% do 10,5% (m/m). W celu zbadania możliwości oznaczenia zawartości wody w szerszym zakresie pomiarowym próbki biomasy suszono w suszarce laboratoryjnej w ciągu 4 godzin w temperaturze 105°C oraz dodatkowo przygotowano próbki modelowe o różnej zawartości wody z wykorzystaniem zmielonej kawy jako matrycy. Na przygotowanych próbkach wykonano badania wilgoci metodą miareczkowania kulometrycznego Karla Fischera z odparowaniem. Przeprowadzone badania potwierdziły, że metoda ta świetnie nadaje się do badania próbek biomasy. Charakteryzuje się bardzo dobrą powtarzalnością w badanym zakresie od 0,7% do 75% (m/m).
The article presents works on the use of coulometric Karl Fischer titration with evaporation for determining water content in biomass. Six types of plant biomass samples were tested: ground coffee obtained as brewed waste, wheat straw, hay, walnut shells and hazel and spruce wood chips. Tests of water content in all obtained products were carried out and their results were compared with two other methods used as standard for biomass moisture testing, i.e. by using a drying balance method and the distillation method. All the methods were found to be in good agreement with the results obtained for the samples tested. The distillation method turned out to be the least useful, as it gave results that differed most from the other methods. The analysis time using this technique is long, it is quite laborious to perform and is not automated. The fastest technique is the method utilizing a drying balance, but it is less precise than the coulometric method. The results obtained with this method may be overestimated as the measure of water content in the tested sample is the loss of mass, which may be related not only to the presence of water, but also to other volatile substances released during the test. On the other hand, the coulometric Karl Fischer titration method is selective and only the water evaporated from the sample is determined during the analysis, even if other volatile substances are released from the sample under the test conditions. The coulometric Karl Fischer titration method with sample evaporation in an oven showed the best precision. It is easy to make and automated. It was found that this method can be successfully used in biomass research. The water content in all obtained biomass samples ranged between 8 and 10.5% (m/m). In order to investigate the possibility of determining the water content in a wider measuring range, the biomass samples were dried in a laboratory dryer for 4 hours at 105°C, and additionally, model samples with different water content were prepared using ground coffee as a matrix. The prepared samples were tested with coulometric Karl Fischer titration with evaporation method. The conducted research confirmed that the method of coulometric Karl Fischer titration with evaporation is perfect for testing biomass samples. It is characterized by a very good repeatability in the tested range, from 0.7 to 75% (m/m).
Źródło:
Nafta-Gaz; 2022, 78, 5; 393-400
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the sorption properties of different soils using water vapour adsorption and potentiometric titration methods
Autorzy:
Skic, K.
Boguta, P.
Sokolowska, Z.
Powiązania:
https://bibliotekanauki.pl/articles/25797.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
sorption property
soil
water vapour adsorption
potentiometric titration
cation exchange capacity
surface area
physicochemical characteristics
Źródło:
International Agrophysics; 2016, 30, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jubileusz metody miareczkowania kulometrycznego
An anniversary of coulometric titration
Autorzy:
Małyszko, J.
Powiązania:
https://bibliotekanauki.pl/articles/171793.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
kulometria
miareczkowanie kulometryczne
miareczkowanie konwencjonalne
reakcje elektrodowe
titrants
coulometry
coulometric titration
conventional titrations
electrode processes
Opis:
In 1938, Szebellédy and Somogyi [1–7] have proposed an important methodological innovation in analytical chemistry. This methodology was termed coulometric titration. This paper presents an overview of the principles of operation and, in broad outline, applications of this methodology. Moreover, a short biography and scientific achievements of professor Laszlo Szebellédy are presented in the introduction. Chapter 1 of this review outlines the theoretical background and general description of coulometric titration. In this new technique, the electrical current generates a titrant that chemically reacts with an analyte. The amount of the analyte is determined from the quantity of the electrical charge passed until the point of chemical equivalence has been reached, according to the 2nd Faraday’s law of electrolysis. The new methodology offers several significant advantages over a conventional volumetric procedure, such as elimination of problems connected with the preparation, standardization and storage of standard solutions. In Chapter 2, an evolution of the method after the Second World War is presented. In these times, stable constant current sources became easy to construct [13–15]. Consequently, coulometric titrations started to use a constant current system. Under these conditions, the total number of coulombs consumed can be calculated readily from the intensity of current and the duration of electrolysis. Coulometric titrations have been developed for all types of volumetric titrations: oxidation–reduction [19–28], precipitation [17, 18], complex formation [37] and neutralization reactions [39, 40]. The generation of various titrants and possibilities of application are described. Special attention is devoted to the electrochemical generation of reagents which are not ordinarily utilized in conventional volumetric analysis owing to the instability of their solutions such as bromine, chlorine, silver(II) and titanium(III). Moreover, the coulometric titration procedure is significantly more sensitive than the volumetric titration, and it is particularly suited to automation, because complex mechanical devices such as an automatic burette are not required. The new method appeared to be an attractive alternative to all forms of the volumetric titration. Chapter 3 is dedicated to the contribution of Polish academic chemistry teachers to the development of the method discussed [57–89, 91–100]. Advantages and disadvantages of the method are listed in the last Chapter (Summary). Each Chapter includes selected works related to the history of the subject.
Źródło:
Wiadomości Chemiczne; 2011, 65, 5-6; 345-361
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Izotermiczna kalorymetria miareczkowa
Autorzy:
Wyrzykowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/274092.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
izotermiczna kalorymetria miareczkowa
ITC
pomiar kalorymetryczny
reakcja kompleksowania
isothermal titration calorimetry
calorimetric measurement
complexation reaction
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 6; 6-11
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
SCREENING THE SPECIFIC SUBSTRATES OF ADENYLATION DOMAIN FROM MARINE ACTINOMYCETES BY FLUORESCENCE QUENCHING AND ISOTHERMAL TITRATION CALORIMETRY
Autorzy:
LEI, MING
ZHAO, ZHIJUAN
LIU, KE
LIU, YANLI
ZHANG, HUI
WU, XUE
GONG, SIYING
MA, YANLING
ZHAO, HAOBIN
LIU, JINLIN
MIN, JINRONG
QI, CHAO
Powiązania:
https://bibliotekanauki.pl/articles/895432.pdf
Data publikacji:
2018-12-31
Wydawca:
Polskie Towarzystwo Farmaceutyczne
Tematy:
A domain
Aspartic acid
Fluorescence quenching (FQ)
Isothermal titration calorimetry (ITC)
Marine actinomycetes
static quenching
Opis:
Adenylation domain (A domain) is a model of non-ribosomal peptide synthetases (NRPs), responsible for binding and activating the substrates-amino acids. In this study, a pGEX-2T-sare0718 recombinant plasmid (the gene sare0718 was cloned from Salinispora arenicola CNS-205, S.arenicola CNS-205) was transformed and expressed as a protein GST-Sare0718. Fluorescence quenching (FQ) was conducted to investigate the binding of 20 common amino acids to GST-Sare0718, then isothermal titration calorimetry (ITC) also be used[changed]. The results of FQ revealed that intrinsic fluorescence of GST-Sare0718 is quenched steadily by addition of aspartic acid (Asp) and glutamine (Gln) through static quenching mechanism. The binding constants Ka are Asp (1.504×106 L/mol) ≥ Gln (1.468×105 L/mol). And there is one binding site on the protein GST-Sare0718. We confirmed Asp preference of GST-Sare0718 by ITC. Therefore, Asp is the specific substrate. In addition, the experimental data indicates that the prediction system, “the specificity-conferring code”, is not suitable for marine actinomycetes. So it is urgent to set up a special predictive system for marine actinomycetes.
Źródło:
Acta Poloniae Pharmaceutica - Drug Research; 2018, 75, 6; 1287-1292
0001-6837
2353-5288
Pojawia się w:
Acta Poloniae Pharmaceutica - Drug Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel method for thermodynamic study on the binding of milk carrier protein of BLG-A with Cr+3
Autorzy:
Behbehania, G.R.
Divsalar, A.
Saboury, A.A.
Powiązania:
https://bibliotekanauki.pl/articles/778861.pdf
Data publikacji:
2009
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
BLG-A
Cr+3
izotermiczna kalorymetria miareczkowa
kalorymetria
Cr3+
isothermal titration calorimetry
binding parameters
Opis:
Thermodynamics of the interaction between Cr3+ with β-lactoglobulin type A (BLG-A) was investigated at pH 7.0 and 37°C by isothermal titration calorimetry. A new method to follow the effect of Cr3+ on the stability of BLG-A was introduced. The new solvation model was used to reproduce the enthalpies of BLG-A+ Cr3+ interactions over the whole range of Cr3+ concentrations. The solvation parameters recovered from the new equation are attributed to the structural change of BLG-A and its biological activity. The results obtained indicate that there is a set of two identical binding sites for Cr3+ ions with positive cooperativity. The association equilibrium constants are 14.39 and 0.49 mM-1 for the first and second binding site, respectively. The enthalpy of binding for one mole of Cr+3 ion to one mole of the binding site on BLG-A (ΔH=104.60 kJ mol-1) is obtained.
Źródło:
Polish Journal of Chemical Technology; 2009, 11, 4; 24-29
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O miareczkowym oznaczaniu laktozy i sacharozy obok siebie
Opredelenie laktoza i sakharoza nakhodjashhikhsja sovmestno pri pomoshhi titravanija
On the estimation of lactose and saccharose existing together in a solution by means of titration
Autorzy:
Rozental, L.
Powiązania:
https://bibliotekanauki.pl/articles/875529.pdf
Data publikacji:
1958
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
laktoza
sacharoza
zawartosc
produkty spozywcze
oznaczanie
metoda miareczkowa
lactose
saccharose
content
food product
determination
titration method
Źródło:
Roczniki Państwowego Zakładu Higieny; 1958, 09, 5
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie olejków eterycznych na podstawie ich odmiennej rozpuszczalności w mieszaninach acetonowo-metanolowych
Issledovanie ehfirnykh masel na osnovanii razlichnojj rastvorimosti ikh v smesi acetona i metilovogo spirta
Examination of volatile oils on the basis of their different solubility in acetone-methanol mixtures
Autorzy:
Bulinski, R.
Powiązania:
https://bibliotekanauki.pl/articles/877361.pdf
Data publikacji:
1958
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
olejki eteryczne
identyfikacja
metoda miareczkowa
zwiazki terpenowe
starzenie sie
zywicowanie
essential oil
identification
titration method
terpene compound
senescence
resin
Źródło:
Roczniki Państwowego Zakładu Higieny; 1958, 09, 6
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunkowy błąd systematyczny przy oznaczaniu kwasu L-askorbinowego metodami miareczkowymi
Sistematicheskaja oshibka vystupajushhaja pri oboznachenii L-askorbinovojj kisloty titrovannymi metodami
Systematic error in L-ascorbic acid determination by means of volumetric methods
Autorzy:
Bozyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/875669.pdf
Data publikacji:
1962
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
kwas L-askorbinowy
oznaczanie
metoda miareczkowa
2,6-dwuchlorofenoloidofenol
bledy systematyczne
L-ascorbic acid
determination
titration method
systematic error
Źródło:
Roczniki Państwowego Zakładu Higieny; 1962, 13, 3
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad oznaczaniem miedzi w ściekach, metody miareczkowe i wagowe
Issledovanija nad oboznacheniem medi v stochnykh vodakh
Studies on copper determination in sewage. Volumetric and gravimetric methods
Autorzy:
Dozanska, W.
Powiązania:
https://bibliotekanauki.pl/articles/873217.pdf
Data publikacji:
1962
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
scieki
miedz
oznaczanie
metody oznaczania
metoda miareczkowa
metoda wagowa
metoda jodometryczna
sewage
copper
determination
determination method
titration method
weighing method
iodometric method
Źródło:
Roczniki Państwowego Zakładu Higieny; 1962, 13, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania kulometryczne na Wydziale Chemii Uniwersytetu Warszawskiego
Coulometric studies in the Department of Chemistry of the University of Warsaw
Autorzy:
Galus, Z.
Powiązania:
https://bibliotekanauki.pl/articles/171596.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
kulometria
miareczkowanie kulometryczne
kulometria przy stałym potencjale
chronokulometria
chronokulometria cienkich warstw
woltochronokulometria
coulometry
coulometric titration
constant potential coulometry
chronocoulometry
thin layer chronocoulometry
voltochronocoulometry
Opis:
The coulometric studies carried out in the Department of Chemistry of the University of Warsaw have been described. In the first part of this brief review there were discussed papers in which coulometric titration was used as a main method of the study. In this section the achievements of Stanisław Głąb and his coworkers in that field were shortly described and discussed. Both the use of the coulometric titration in elaboration of a new analytical titration methods and its application to the determination of equilibrium constants of several reactions have been presented. In the second part, the results obtained with the use of two variants of constant potential coulometry were presented. In the first classical variant, the thickness of the solution layer (d), from which occurs the diffusion to the electrode was much larger than the diffusion layer thickness (δ), d » δ. In the second variant inequality d « δ is obeyed. The later case relates to the so-called thin-layer chronocoulometry, when the reactive layer (solution or film on the electrode) is very thin. Some papers published by the researchers from the Chemistry Department of the University of Warsaw were presented, especially those where thin layers of heavy metal (as iron, nickel, cobalt and others) hexacyanoferrates such as for instance Prussian Blue, were deposited either on platinum, gold, glassy carbon electrodes or on carbon nanotubes. The transport of charge in such layers was briefly discussed. In the last part, the application of so-called voltochronocoulometry by researchers of the Chemistry Department of the University of Warsaw to the study of different electrode reactions and double layer phenomena is presented.
Źródło:
Wiadomości Chemiczne; 2015, 69, 9-10; 631-651
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd zastosowań spektroskopii w zakresie bliskiej podczerwieni w analizie wilgotności śladowej w produktach leczniczych weterynaryjnych immunologicznych
Review of applications of near infrared spectroscopy in analysis of residual moisture in immunological veterinary medicinal products
Autorzy:
Bulenger, K.
Biernacki, B.
Krasucka, D. M.
Szumiło, J.
Cuvelier, B.
Powiązania:
https://bibliotekanauki.pl/articles/171718.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
spektroskopia NIR
bliska podczerwień
miareczkowanie Karla Fischera
model ilościowy
woda śladowa
oznaczanie
near infrared spectroscopy
NIRS
Karl Fischer titration
quantitative model
residual water determination
Opis:
However, the infrared radiation has been discovered more than 200 years ago, near-infrared spectroscopy (NIRS), as a useful method, was recognized in the 1960s. Currently, under the influence of technological development, quantitative and qualitative methods require short time and precision of measurements. NIRS has a growing recognition in the industry, particularly pharmaceutical where each component of the finished product has impact on the quality and safety of the product. Freeze-dried immunological veterinary medicinal products (IVMPs), despite high specificity, contain not too complicated matrices for analysis. Karl Fischer titration is routinely used as accurate and effective method to determine the water content in the IVMPs, but the use of near-infrared spectroscopy allows to avoid the adverse impact of environmental factors on the measurements. However, for NIRS, there is a need to create a calibration model which will be precise for high diversity of samples. The most important is the optimization of the model by eliminating the factors that might influence the measurement of water content. Quantification methods most frequently used are: MLR, PLS and PCR, which are preceded by the appropriate pretreatments (derivatives of Savitzky Golay).
Źródło:
Wiadomości Chemiczne; 2016, 70, 11-12; 747-759
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie wapnia i magnezu w artykułach żywności ze szczególnym uwzględnieniem metod kompleksometrycznych
Opredelenie kalcija i magnija v pishhevykh produktakh, osobenno uchityvaja kompleksometrcheskijj metod
Estimation of calcium and magnesium in foods with particular reference to complexometric methods
Autorzy:
Oledzka, R.
Krauze, S.
Powiązania:
https://bibliotekanauki.pl/articles/875284.pdf
Data publikacji:
1959
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zywnosc
produkty spozywcze
wapn
magnez
oznaczanie
zwiazki kompleksowe
miareczkowanie kompleksometryczne
badania laboratoryjne
food
food product
calcium
magnesium
determination
complex compound
complexometric titration
laboratory test
Źródło:
Roczniki Państwowego Zakładu Higieny; 1959, 10, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad metodą Pijanowskiego. VII. Dokładne oznaczanie zawartości kwasu L-dehydroaskorbinowego w wyciągach warzyw i owoców
Issledovanija nad metodom Pijanovskogo. VII. Tochnoe opredelenie kolichestva L-degidroaskorbinovojj kisloty v vytjazhkakh ovoshhejj i fructov
Studies on Pijanowskis method. VII. Accurate determination of L-dehydroascorbic acid content in fruit and vegetable extracts
Autorzy:
Bozyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/876118.pdf
Data publikacji:
1963
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
kwas L-dehydroaskorbinowy
kwas L-askorbinowy
oznaczanie
metoda miareczkowa
owoce
warzywa
wyciagi
L-ascorbic acid
L-dehydroascorbic acid
determination
titration method
fruit extract
vegetable extract
Źródło:
Roczniki Państwowego Zakładu Higieny; 1963, 14, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emulsje podwójne i potrójne z modyfikowanymi powierzchniami kropel jako nośniki substancji czynnych
Double and triple emulsions with modified drops surface as the carriers of active agents
Autorzy:
Metera, A.
Markowska-Radomska, A.
Dłuska, E.
Kosicki, K.
Tudek, B.
Frączyk, T.
Powiązania:
https://bibliotekanauki.pl/articles/2073206.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
emulsje wielokrotne
kontaktor helikoidalny
modyfikacja powierzchni kropel
terapia celowana
izotermiczne miareczkowanie kalorymetryczne
multiple emulsions
helical flow contactor
drops surface modification
targeted therapies
isothermal titration calorimetry
Opis:
emulsji podwójnych jako potencjalnych nośników substancji czynnych do celowanego uwalniania. Modyfikacja polegała na adsorpcji fizycznej przeciwciał CD15 na powierzchniach kropel, fazy membranowej emulsji W1/O/W2. Stan adsorpcji przeciwciał był oceniony na podstawie analizy efektu cieplnego wszystkich oddziaływań międzycząsteczkowych przy użyciu metody izotermicznego miareczkowania kalorymetrycznego. Wyznaczony efekt cieplny oddziaływań przeciwciała i składników fazy membranowej potwierdził ich adsoipcję na powierzchniach kropel fazy membranowej emulsji W1/O/W2.
The paper presents an investigation into drops’ surface modification of double emulsions as the potential carriers of active agents in targeted therapies. Physical adsorption of CD 15 antibodies on surfaces of membrane phase drops of emulsions W1/O/W2 was evaluated by measuring the heat effect of all molecular interactions using the isothermal titration calorimetry method. The calculated effect of interaction between molecules of antibodies (proteins) and drops of membrane phase ingredients confirmed adsorption of proteins on surfaces of emulsions drops.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 3; 92--93
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza fizykochemiczna odpadu z instalacji odsiarczania spalin metodą półsuchą z elektrociepłowni przemysłowej w Janikowie
Physico-chemical analysis of the waste from installation of semi-dry flue gas desulfurization of industrial chp plant in Janikowo
Autorzy:
Plaskacz-Dziuba, M
Buczkowski, R.
Igliński, B
Cichosz, M.
Dziuba, P
Powiązania:
https://bibliotekanauki.pl/articles/400630.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
odsiarczanie spalin
metoda półsucha
instalacja NID
pośrednie miareczkowanie jodometryczne
siarczan(IV) wapnia
semi-dry flue gas desulphurisation
Novel Integrated Desulphurisation installation
indirect iodometric titration
calcium sulphite
Opis:
W pracy przedstawiono wyniki analizy odpadów z instalacji odsiarczania spalin metodą półsuchą ang. Novel Intergrated Desulphurisation (NID). Przeprowadzono kompleksową analizę fizykochemiczną, m.in. wykonano analizy zawartości jonów SO32- i SO42- (w przeliczeniu na 2CaSO3 H2O i CaSO4 2H2O), wilgoci, SiO2 i R2O3 oraz analizy SEM-EDX. Zaprojektowano oryginalną metodę oznaczania siarczanów(IV) przy użyciu titratora potencjometrycznego. Wyznaczono, iż głównym składnikiem obu badanych odpadów był 2CaS3 H2O, a jego zawartość wynosiła dla NID 1 – 41,24±0,63%, dla NID 2 – 45,53±0,33%. Zawartość CaSO4 2H2O, którą wyznaczono metodą wagową, wynosiła dla NID 1 – 8,92±0,12%, dla NID 2 – 8,27±0,08%. Zawartość wilgoci badanych próbek wynosiła około 4%, zawartość SiO2 w granicach 8–10%, a zawartość R2O3 około 1%. Wykazano również, że badane materiały nie są homogeniczne. Na obrazach z elektronowego mikroskopu skaningowego widoczne były nieregularnie występują aglomeraty o średnicy od 30 do 100 μm. Analizy EDX wykazały, iż pierwiastkami wchodzącymi w skład odpadów NID są tlen, siarka, wapń, chlor, krzem, glin, miedź oraz węgiel.
The paper presents results of the analysis of waste from semi-dry flue gas desulphurisation installation called Integrated Novel Desulphurisation (NID). A comprehensive analysis of the physicochemical properties was conducted, including analyzes of the content of ions SO32- and SO42- (relating to 2CaSO3 H2O and CaSO4 2H2O), moisture, SiO2 and R2O3 and SEM-EDX analysis. The original method for the determination of sulphates (IV) using a potentiometric titrator was designed. Determined that the main component of both studied wastes was 2CaSO3 H2O, and its content is for NID 1 – 41,24±0,63%, for NID 2 – 45,53±0,33%. The content of CaSO4 2H2O, which was determined by gravimetric method amounted for the NID 1 – 8,92±0,12%, for the NID 2 – 8,27±0,08%. The moisture content for both tested materials was about 4%, the content of SiO2 was in the range of 8–10%, and R2O3 content was about 1%. It was also shown that the test material is not homogenous. Images from scanning electron microscope showed that in the waste occured irregularly agglomerates with a diameter between 30 and 100 microns. EDX analysis revealed that elements constituted NID wastes are oxygen, sulfur, calcium, chlorine, silicon, aluminum, copper and carbon.
Źródło:
Inżynieria Ekologiczna; 2014, 38; 91-105
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody wyznaczania krytycznego stężenia micelarnego związków powierzchniowo czynnych
Methods for determining critical micellar concentration of surfactants
Autorzy:
Grabowska, Ola
Dywicki, Paweł
Chmurzyński, Lech
Powiązania:
https://bibliotekanauki.pl/articles/171754.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Chemiczne
Tematy:
związki powierzchniowo czynne
krytyczne stężenie micelarne
konduktometria
elektroforeza kapilarna
izotermiczna kalorymetria miareczkowa
metoda luminescencyjna
surface active agents
critical micelle concentration
conductometry
capillary electrophoresis
isothermal titration calorimetry
luminescent method
Opis:
Surface active agents, also known as surfactants, are a group of chemical compounds that are used in various products of the chemical industry. These compounds are components of medicines, detergents, motor oils and many others. The multitude of uses of surfactants makes it important to know their aggregation behaviour in solution. There are many methods used to analyse surfactants behaviour in liquid phase. The choice of a particular technique usually depends on the chemical structure of the surfactant. An example of a method that is used in studies of ionic surfactants is conductometry. This technique allows to study the dependence of specific conductivity on surfactant concentration, enabling determination of critical micellar concentration (CMC). Capillary electrophoresis is another example of the method used to determine the critical micellar concentration. It allows to make measurements in conditions where other methods fail, including conductometric method. Surfactant solutions differ in viscosity, which changes with the appearance of micelles in solution. Measurement of marker compound migration time through surfactant solutions of various concentrations allow to determine critical micellar concentration. Isothermal titration calorimetry (ITC) allows to study the thermal effects associated with the aggregation of surfactants into micelles. Based on the energy changes that occur during titration, the critical micellar concentration of surfactant can be precisely determined. ITC is very sensitive method, so basically it can be used to examine all types of surfactants. In addition, the ITC method allows to determine the thermodynamic parameters of the undergoing micellization process. The use of several measuring methods gives a more complete picture of the phenomena occurring in solutions. It allows to understand aggregation process more accurately. Therefore, CMC measurement are often made with the use of several complementary methods.
Źródło:
Wiadomości Chemiczne; 2020, 74, 5-6; 371-390
0043-5104
2300-0295
Pojawia się w:
Wiadomości Chemiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diurnal and Seasonal Variations in the NO2 Photolysis Rate Constant, NO Titration Rate Constant and the NO2/NO Ratio in Ambient Air in the City of Olsztyn
Dobowa i sezonowa zmienność stałych szybkości reakcji fotolizy NO2 i titracji NO oraz stosunku NO2/NO w powietrzu atmosferycznym Olsztyna
Autorzy:
Warmiński, K.
Bęś, A.
Powiązania:
https://bibliotekanauki.pl/articles/389756.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
fotoliza NO2
titracja NO
stałe szybkości reakcji
stosunek NO2/NO
fotochemia troposfery
ozon troposferyczny
NO2 photolysis
NO titration
rate constant
NO2/NO ratio
tropospheric photochemistry
tropospheric ozone
Opis:
The paper presents diurnal and seasonal variations in the NO2 photolysis rate constant (JNO,), NO titration rate constant (k3) and the NO2/NO molecular ratio determined experimentally and calculated for the photostationary state in atmospheric air in the city of Olsztyn (NE Poland). Diurnal variations in the titration rate constant ranged from 20.8 to 25.3 ppm-1 min-1 in the summer (June 2008), and from 16.5 to 17.2 ppm -1 min-1 in the winter (December 2008). The values of the JNO2 constant, which is dependent on the total solar radiation (TSR) and the solar zenith angle (SZA), ranged from zero in night hours to 0.071 min-1 at 12:00 noon local time in the winter and to 0.254 min-1 11:00 a.m. local time in the summer. The NO2/NO ratio (both observed and calculated) showed characteristic diurnal variations, reaching a minimum around noon. The determined NO2/NO ratio was found to be higher than the calculated NO2/NO ratio both in the summer and winter. The lowest values of the calculated NO2/NO ratio were noted in June, with an average of 0.0407 at 12:00 noon, which was 176-fold lower than the value determined experimentally. This points to the significance of NO oxidation to NO2 with the participation of volatile organic compounds (VOCs) and/or carbon monoxide.
W pracy przedstawiono wyniki zmienności stałych szybkości reakcji fotolizy N02 (JNO2) i titracji NO (k3), a także stosunku stężeń NO2/NO wyznaczonego eksperymentalnie oraz obliczonego dla stanu fotostacjonarnego w powietrzu atmosferycznym Olsztyna. Stała titracji w miesiącu letnim (czerwiec 2008 r.) wahała się w ciągu doby w zakresie od 20.8 do 25.3 ppm-1 o min-1, natomiast w miesiącu zimowym (grudzień 2008 r.) - w zakresie od 16.5 do 17,2 ppm-1 o min-1. Z kolei stała JNO2, która zależy od natężenia całkowitego promieniowania słonecznego i kąta zenitalnego Słońca, wahała się od zera w godzinach nocnych do 0.071 min-1 o godzinie 12:00 czasu lokalnego zimą i 0.254 min-1 o godz. 11:00 latem. Stosunek NO2/NO wykazuje charakterystyczną zmienność dobową z minimum przypadającym na godziny południowe. Zarówno latem, jak i zimą obserwowany stosunek NO2/NO jest większy niż obliczony. W czerwcu stwierdzono najmniejsze wartości obliczonego stosunku NO2/NO, którego średnia o godzinie 12:00 wynosiła 0.0407 i była aż 176 razy mniejsza niż wartość NO2/NO wyznaczona eksperymentalnie. Wskazuje to na duże znaczenie reakcji utleniania NO do NO2 z udziałem lotnych związków organicznych (VOC) i/lub tlenku węgla.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 8; 1029-1037
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oznaczanie arsenu w ściekach
Opredelenie myshjaka v stochnykh vodakh
Estlmation of arsenic in sewage and industrial wastes
Autorzy:
Dozanska, W.
Czarnodolowa, H.
Powiązania:
https://bibliotekanauki.pl/articles/872876.pdf
Data publikacji:
1959
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
arsen
oznaczanie
metoda miareczkowa
kalorymetria
scieki przemyslowe
wody powierzchniowe
woda studzienna
wlasciwosci toksyczne
dawki dopuszczalne
arsenic
determination
titration method
colorimetry
industrial sewage
surface water
well water
toxic property
acceptable dose
Źródło:
Roczniki Państwowego Zakładu Higieny; 1959, 10, 3
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wybranych metod oznaczania kwasu mlekowego
Autorzy:
Czarnecka, M
Czarnecki, Z.
Roszyk, H.
Powiązania:
https://bibliotekanauki.pl/articles/826269.pdf
Data publikacji:
2000
Wydawca:
Polskie Towarzystwo Technologów Żywności
Tematy:
metody enzymatyczne
przemysl spozywczy
przemysl paszowy
kolorymetria
kwas mlekowy
oznaczanie
metoda HPLC
metody fluorymetryczne
miareczkowanie kolorymetryczne
enzymatic method
food industry
feed industry
calorimetry
lactic acid
determination
high performance liquid chromatography
fluorometric method
colorimetric titration
Opis:
Przeprowadzono ocenę i porównanie następujących metod oznaczania kwasu mlekowego: miareczkowej, kolorymetrycznej, fluorymetrycznej, enzymatycznej oraz HPLC. Opracowano metodę ilościowego oznaczania kwasu mlekowego w oparciu o technikę HPLC oraz porównano wyniki uzyskane tą metodą z wynikami uzyskanymi przy pomocy innych metod. Dokonano oceny dokładności tych metod w oparciu o odzysk, oraz ocenę precyzji na podstawie współczynnika zmienności.
HPLC method for determination of lactic acid in presence of other organic acids was elaborated and compared to the other methods. This method was compared to titratic, colorimetric, fluorometric and enzymatic procedures according to their specifity, accuracy and precision.
Źródło:
Żywność Nauka Technologia Jakość; 2000, 07, 1; 92-101
1425-6959
Pojawia się w:
Żywność Nauka Technologia Jakość
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-32 z 32

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies