Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "time-to-digital converter" wg kryterium: Temat


Tytuł:
A time interval generator with the STM32 microcontroller
Autorzy:
Sawicki, M.
Różyc, K.
Powiązania:
https://bibliotekanauki.pl/articles/114557.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
microcontroller
time delay
time-to-digital converter
Opis:
The paper presents a concept of utilization of counter-timer circuits built in popular microcontrollers for generating precise time intervals. The main aim was to generate pulses START and STOP wholly in hardware without using a core of the microcontroller. This enables minimizing the value of time jitter of the generated time intervals and allows the use of remaining resources of the microcontroller freely. The introduced method of generation exploits the possibility of simultaneous synchronization of TIM2 and TIM3 timers from an overloaded TIM1 timer. Dependent timers work in One Pulse Mode. START and STOP signals are generated by PWM channels of individual timers. PWM channels can be configured independently which gives the possibility to generate START and STOP pulses of different polarity and width. Generation of a time interval can be triggered automatically (TIM1) or through one of the inputs of the microcontroller. The implemented generator is characterized by the generated range of time interval from 0 to 100 s and the resolution of 40 ns. The jitter of 100 ps was obtained. The concept is suitable to apply in any microcontroller of the STM32 family. It allows the generation of precise and adjustable delays in the application without the need to significantly expand a hardware part of the device.
Źródło:
Measurement Automation Monitoring; 2015, 61, 7; 296-298
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An autonomous microcontroller system for controlling a multi-channel time counter
Autorzy:
Sondej, D.
Sawicki, M.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/114671.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
microcontroller
time counter
autonomous system
time-to-digital converter
Opis:
The paper presents the design of a microprocessor system intended for control, data processing and communication in a multi-channel time counter. The time counter is a relatively complex autonomous instrument designed for measurements of time with picosecond precision and frequency within a range of 3.5 GHz. The device employs a high-speed, single-chip microcontroller with event-driven programming without the mediation of an operating system. The autonomous operation of the measurement system with real-time controlling and data processing was achieved. The paper focuses on the hardware design and the software development model which enables collision-free and concurrent work of many components. The device uses advanced mechanisms available in STM32 series microcontrollers, allowing the efficient support for USB and Ethernet interfaces. The microprocessor system works at a relatively low frequency, which minimizes emission of interference and allows measuring time intervals with a high precision.
Źródło:
Measurement Automation Monitoring; 2015, 61, 7; 305-307
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantization error in time-to-digital converters
Autorzy:
Zaworski, Ł.
Chaberski, D.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221677.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval measurement
time-to-digital converter
quantization error
averaging
Opis:
Methods of time interval measurement can be divided into asynchronous and synchronous approaches. It is well known that in asynchronous methods of time-interval measurement, uncertainty can be reduced by using statistical averaging. The motivation of this paper is an investigation of averaging in time interval measurements, especially in a synchronous measurement. In this article, authors are considering the method of averaging to reduce the influence of quantization error on measurement uncertainty in synchronous time-interval measurement systems, when dispersion of results, caused by noise is present. A mathematical model of averaging, which is followed by the results of numerical simulations of averaging of measurement series is presented. The analysis of results leads to the conclusion that in particular conditions the influence of the quantization error on measurement uncertainty can be minimized by statistical averaging, similar to asynchronous measurements.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 115-122
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic flow measurement with high resolution
Autorzy:
Grzelak, S.
Czoków, J.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221448.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic flowmeter
time-to-digital converter
programmable logic device
time measurement
Opis:
The ultrasonic flowmeter which is described in this paper, measures the transit of time of an ultrasonic pulse. This device consists of two ultrasonic transducers and a high resolution time interval measurement module. An ultrasonic transducer emits a characteristic wave packet (transmit mode). When the transducer is in receive mode, a characteristic wave packet is formed and it is connected to the time interval measurement module inputs. The time interval measurement module allows registration of transit time differences of a few pulses in the packet. In practice, during a single measuring cycle a few time-stamps are registered. Moreover, the measurement process is also synchronous and, by applying the statistics, the time interval measurement uncertainty improves even in a single measurement. In this article, besides a detailed discussion on the principle of operation of the ultrasonic flowmeter implemented in the FPGA structure, also the test results are presented and discussed.
Źródło:
Metrology and Measurement Systems; 2014, 21, 2; 305-316
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High resolution time-interval measurement systems applied to flow measurement
Autorzy:
Grzelak, S.
Kowalski, M.
Czoków, J.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221586.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FPGA
time-to-digital converter
multi-segment delay line
carry chain
Opis:
The designing process of high resolution time interval measurement systems creates many problems that need to be eliminated. The problems are: the latch error, the nonlinearity conversion, the different duty cycle coefficient of the clock signal, and the clock signal jitter. Factors listed above affect the result of measurement. The FPGA (Field Programmable Gate Array) structure also imposes some restrictions, especially when a tapped delay line is constructed. The article describes the high resolution time-to-digital converter, implemented in a FPGA structure, and the types of errors that appear there. The method of minimization and processing of data to reduce the influence of errors on the measurement is also described.
Źródło:
Metrology and Measurement Systems; 2014, 21, 1; 77-84
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time interval measurement module implemented in SoC FPGA device
Autorzy:
Grzęda, G.
Szplet, R.
Powiązania:
https://bibliotekanauki.pl/articles/226962.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval measurement
time-to-digital converter
system on chip
measurement data processing
Opis:
We presents the design and test results of a picosecond-precision time interval measurement module, integrated as a System-on-Chip in an FPGA device. Implementing a complete measurement instrument of a high precision in one chip with the processing unit gives an opportunity to cut down the size of the final product and to lower its cost. Such approach challenges the constructor with several design issues, like reduction of voltage noise, propagating through power lines common for the instrument and processing unit, or establishing buses efficient enough to transport mass measurement data. The general concept of the system, design hierarchy, detailed hardware and software solutions are presented in this article. Also, system test results are depicted with comparison to traditional ways of building a measurement instrument.
Źródło:
International Journal of Electronics and Telecommunications; 2016, 62, 3; 237-246
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ scalony do pomiaru czasu w przepływomierzu ultradźwiękowym
Time measuring circuit for ultrasonic flow-meter
Autorzy:
Zaworski, Ł.
Czoków, J.
Wydźgowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/152190.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepływomierz ultradźwiękowy
konwerter czas-cyfra
metrologia czasu
ultrasonic flowmeter
time-to-digital converter
Opis:
Jedną z zasadniczych części przepływomierza ultradźwiękowego jest układ elektroniczny mierzący czas przejścia impulsu pomiędzy przetwornikami ultradźwiękowymi. Minimalna wartość mierzonego strumienia przepływu zależy od rozdzielczości pomiaru czasu. W referacie przedstawiono metody pomiaru czasu w przepływomierzach ultradźwiękowych wykorzystujących metodę pomiaru odcinka czasowego. W szczególności przedstawiono koncepcję układu scalonego CMOS dedykowanego do pomiaru czasu w przepływomierzach ultradźwiękowych, mających zastosowanie w pomiarach małych strumieni przepływu.
One of a most important parts of ultrasonic flowmeter is electronic circuit, which measures transit time of the ultrasonic signals. Minimal value of measured flow rate depends on resolution of time-to-digital converter. In this paper methods of time-interval measurement in ultrasonic flowmeter are described. Implementation of chosen method in CMOS technology is discussed. Expected quantization error of time-to-digital converter is 174 ps and expected resolution of transit - time measurement using sing-around method is 15 ps.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 6, 6; 383-385
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Employing FPGA DSP blocks for time-to-digital conversion
Autorzy:
Kwiatkowski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/221505.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time-to-digital converter
time coding line
time interval counter
digital signal processing
field-programmable gate array
Opis:
The paper presents a novel implementation of a time-to-digital converter (TDC) in field-programmable gate array (FPGA) devices. The design employs FPGA digital signal processing (DSP) blocks and gives more than two-fold improvement in mean resolution in comparison with the common conversion method (carry chain-based time coding line). Two TDCs are presented and tested depending on DSP configuration. The converters were implemented in a Kintex-7 FPGA device manufactured by Xilinx in 28 nm CMOS process. The tests performed show possibilities to obtain mean resolution of 4.2 ps but measurement precision is limited to at most 15 ps mainly due to high conversion nonlinearities. The presented solution saves FPGA programmable logic blocks and has an advantage of a wider operation range when compared with a carry chain-based time coding line.
Źródło:
Metrology and Measurement Systems; 2019, 26, 4; 631-643
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Interpolators Used for Time-Interval Measurement Systems Based on Multiple-Tapped Delay Line
Autorzy:
Chaberski, D.
Frankowski, R.
Gurski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221043.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval
multiple-tapped delay line
quantization-and-nonlinearity minimization
FPGA
time-to-digital converter
Opis:
The paper describes the construction, operation and test results of three most popular interpolators from a viewpoint of time-interval (TI) measurement systems consisting of many tapped-delay lines (TDLs) and registering pulses of a wide-range changeable intensity. The comparison criteria include the maximum intensity of registered time stamps (TSs), the dependency of interpolator characteristic on the registered TSs’ intensity, the need of using either two counters or a mutually-complementing pair counter-register for extending a measurement range, the need of calculating offsets between TDL inputs and the dependency of a resolution increase on the number of used TDL segments. This work also contains conclusions about a range of applications, usefulness and methods of employing each described TI interpolator. The presented experimental results bring new facts that can be used by the designers who implement precise time delays in the field-programmable gate arrays (FPGA).
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 401-412
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of precise determining the transfer function of picosecond time-to-digital converters
Autorzy:
Sondej, Dominik
Szymanowski, Rafał
Szplet, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/1849060.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time-to-digital converter
equivalent conversion function
delay line
multi-edge coding
wave-union
Opis:
We present two main ways to precisely create the equivalent transfer function of picosecond time-to-digital converters based on commonly used method with tapped time coding delay lines. The ways consist either in evaluation of the quantization steps boundaries of the delay lines or in summation of numbers of the line quantization steps. The paper contains results of comprehensive analysis of both methods. The advantage and high versatility of the addition method is demonstrated.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 539-549
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of precise determining the transfer function of picosecond time-to-digital converters
Autorzy:
Sondej, Dominik
Szymanowski, Rafał
Szplet, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/1848997.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time-to-digital converter
equivalent conversion function
delay line
multi-edge coding
wave-union
Opis:
We present two main ways to precisely create the equivalent transfer function of picosecond time-to-digital converters based on commonly used method with tapped time coding delay lines. The ways consist either in evaluation of the quantization steps boundaries of the delay lines or in summation of numbers of the line quantization steps. The paper contains results of comprehensive analysis of both methods. The advantage and high versatility of the addition method is demonstrated.
Źródło:
Metrology and Measurement Systems; 2021, 28, 3; 539-549
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precyzyjny konwerter czasowo-cyfrowy wykorzystujący metodę skracania impulsu zrealizowany w układzie FPGA
Precise time-to-digital converter based on pulse-shrinking implemented in FPGA device
Autorzy:
Szplet, R.
Klepacki, K.
Powiązania:
https://bibliotekanauki.pl/articles/155687.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
precyzyjna metrologia czasu
konwerter czas-liczba
skracanie impulsu
precise time metrology
time-to-digital converter
pulse-shrinking
Opis:
W artykule przedstawione są projekt i wyniki badań konwertera czas-liczba o rozdzielczości 75 ps i zakresie pomiarowym 5.5 ns. Konwerter został zrealizowany w układzie programowalnym Spartan3 firmy Xilinx. Do konwersji czasowo-cyfrowej zastosowano metodę skracania impulsu. W konwerterze wykorzystano cyfrowy detektor zboczy impulsu, który umożliwia kontrolowanie wartości rozdzielczości i uniezależnia mierzony czas trwania impulsu od niekorzystnego wpływu linii transmisyjnych i programowalnych matryc połączeniowych.
This paper describes design and test results of the time-to-digital converter with 75 ps resolution and 5.5 ns measurement range. The converter is implemented in a single programmable device from family Spartan3 (Xilinx). The pulse-shrinking method is used for time-to-digital conversion. Digital pulse-edges detector is applied to control of the conversion resolution and to do measured width time of pulse independent from disadvantageous influence of transmission lines and programmable switch matrixes.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 7, 7; 21-23
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielokanałowy modułowy licznik czasu z użyciem układów programowalnych
A modular multi-channel time counter using programmable devices
Autorzy:
Różyc, K.
Szplet, R.
Kwiatkowski, P.
Sawicki, M.
Jachna, Z.
Powiązania:
https://bibliotekanauki.pl/articles/158352.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układy programowalne
przetworniki czasowo-cyfrowe
licznik czasu
interpolacja dwustopniowa
time counter
programmable device
time-to-digital converter
two-stage interpolation
Opis:
Przedstawiono budowę, zasadę działania i wyniki badań wielokanałowego modułowego licznika czasu. Umożliwia on równoczesny pomiar relacji czasowych pomiędzy impulsami wejściowymi (START), pochodzącymi z maksymalnie sześciu niezależnych źródeł zegarowych, a wspólnym dla wszystkich kanałów impulsem odniesienia (STOP). Moduły pomiarowe licznika wykonano z użyciem układów programowalnych FPGA Spartan-3 (Xilinx). Licznik charakteryzuje się zakresem pomiarowym do 1 s oraz precyzją pomiarów nie gorszą niż 250 ps.
We present the design, operation and test results of a modular multichannel time counter built with the use of programmable devices. Its resolution is below 50 ps and the measurement range reaches 1 sec. The design of the counter is shown in Fig. 1. It consists of six independent measurement modules. Each measurement module contains a 2-channel time interval counter (Fig. 2) implemented in a general-purpose reprogrammable device Spartan-3 (Xilinx). To obtain both high precision and wide measurement range, the counting of periods of a reference clock is combined with a two-stage interpolation within a single period of the clock signal [6]. The interpolation involves a four-phase clock in the first interpolation stage [8] and a time delay coding line in the second interpolation stage. The reference clock module contains an integrated digital synthesizer [7], that provides the reference clock signal of 250 MHz for measurement modules, and is driven by an external clock source of 5 MHz or 10 MHz. The standard measurement uncertainty of the time counter was tested (Figs. 3 and 4) carefully and it did not exceed 250 ps in the full measurement range. As the acid test of the time counter, the differences between signals of 1 PPS from the tested clock sources and the reference 1 PPS signal were also verified (Figs. 5 and 6). The modular design makes the multi-channel time counter easy to modify to meet requirements of various applications.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 7, 7; 432-434
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie układów FPGA w konstrukcji przepływomierzy ultradźwiękowych
Application of FPGA devices to ultrasonic flowmeter
Autorzy:
Zaworski, Ł.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/156070.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przepływomierz ultradźwiękowy
przetwornik czas-cyfra
układ programowalny
pomiar czasu
ultrasonic flowmeter
time-to-digital converter
programmable logic device
time measurement
Opis:
Przepływomierze ultradźwiękowe mierzące różnicę czasu przelotu impulsu przez medium stanowią jedną z dwóch najbardziej rozpowszechnionych grup przepływomierzy. W artykule tym została przedstawiona konstrukcja systemu pomiaru odcinka czasu zaimplementowanego w strukturze programowalnej FPGA jak również metoda kalibracji i wyznaczenia rozdzielczości przetwornika czas/cyfra w trakcie pomiaru. Takie rozwiązanie zapewnia niewrażliwość układu na czynniki zewnętrzne (temperatura), oraz skrócenie czasu pomiaru, a tym samym redukcję poboru energii, co jest atutem przy zasilaniu bateryjnym.
The ultrasonic flowmeter market is the fastest-growing market in any flowmeter type, and transit-time flowmeters have the largest share in that market. One of the fundamental parts of a transit-time ultrasonic flowmeter is a time measurement circuit, often implemented in CMOS ASIC. This paper describes an application of a low-power FPGA device to the transit-time flowmeter time measurement circuit. The main problem discussed in this work is calibration of a delay line in TDC implemented in a FPGA device. The time- and resource-consuming code density testing is undesirable for mass production devices. In this paper a fast and simple method for calibration is proposed. The method is based on measurement of the clock period length [5] and analysis of the data; therefore, it does not require implementation of any additional circuits in the device. A resolution of TDC is estimated by (2), when I_T is the largest state of a decoder in measurement series, and T_0 is clock period. The method uncertainty is larger than that of the code density test, but the method requires virtually no resources and takes less time - under certain conditions the calibration can be performed simultaneously with the measurement. At the end the measurement results and the conclusions are presented.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1511-1514
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A time-domain pulse amplitude and width discrimination method for photon counting
Autorzy:
del Mar Correa, M.
Pérez, F. R.
Powiązania:
https://bibliotekanauki.pl/articles/220971.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
field-programmable gate array
time-to-digital converter
spectroscopy
photomultiplier
photon counting
discriminator
after-pulsing
low-voltage differential signalling
Opis:
This work shows a time-domain method for the discrimination and digitization of parameters of voltage pulses coming from optical detectors, taking into account the presence of electronic noise and afterpulsing. Our scheme is based on an FPGA-based time-to-digital converter as well as an adjustable-threshold comparator complemented with commercial elements. Here, the design, implementation and optimization of a multiphase TDC using delay lines shorter than a single clock period is also described. The performance of this signal processing system is discussed through the results from the statistical code density test, statistical distributions of measurements and information gathered from an optical detector. Unlike dual voltage threshold discriminators or constant-fraction discriminators, the proposed method uses amplitude and time information to define an adjustable discrimination window that enables the acquisition of spectra.
Źródło:
Metrology and Measurement Systems; 2018, 25, 2; 269-282
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies