Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal factor" wg kryterium: Temat


Tytuł:
Adaptive response of parasites to the thermal factor
Autorzy:
Zharikova, T.
Izyumova, N.
Stepanova, M.
Powiązania:
https://bibliotekanauki.pl/articles/838530.pdf
Data publikacji:
1998
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
parasite
water body
Monogenea
thermal factor
Dactylogyrus
chitinoid formation
copepod
Źródło:
Annals of Parasitology; 1998, 44, 3
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of serrated circular rings on heat transfer augmentation of circular tube heat exchanger
Autorzy:
Kharkwal, Himanshi
Singh, Satyendra
Powiązania:
https://bibliotekanauki.pl/articles/2091375.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer rate
friction factor
thermal performance factor
serrated circular ring
Opis:
Limiting energy resources has led researchers to find new innovative ways to enhance heat exchanging devices thermal performance in power generating systems. Thus, the present paper analyzes passive techniques of enhancing the thermal performance of a single tube heat exchanger. Experimental and numerical investigation on heat transfer enhancement using aserrated circular ring with twisted tape is carried out. The work incorporates the determination of Nusselt number, friction factor, thermal performance factor for serrated circular ring with twisted tape with variation in diameter ratio (0.8 and 0.85) and pitch ratio (2 and 3). Air is used as a working fluid with Reynolds number 6000–24000. The experiment is conducted by providing a constant wall heat flux of 1000 W/m2 to the system and thereby taking results at a steady state. The experimental and computational findings obtained for the smooth tube case are compared with the standard correlations of Dittus–Boelter and Blasius. Based on experimental and numerical investigation, there is 5.16 times augmentation in heat transfer and 3.05 times improvement in thermal performance factor over the smooth tube heat exchanger. In addition, the study of entropy generation rate for every geometrical parameter has been conducted, and their influence on the system’s thermal behaviour is presented. The results obtained in the present study may help the researchers of the same research area to find similar inserts and new ways of enhancing the thermal performance of heat exchangers.
Źródło:
Archives of Thermodynamics; 2022, 43, 2; 129--155
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and numerical study of the heat transfer and pressure drop in triangular chevron channels
Autorzy:
Dolatabadi, H.
Aghdam, A. H.
Powiązania:
https://bibliotekanauki.pl/articles/949298.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
heat transfer
pressure drop
thermal enhancement factor
phase shift
Opis:
Experimental and Numerical studies were carried out on turbulent heat transfer and friction factor loss through a triangular chevron channel. For uniform wall heat flux equal 1350 (W/m²) using air as a working fluid. Reynolds number varied from 3000 to 10000, phase shifted at the range of 0≤ϕ≤180, with variation distance between chevron surfaces (5 ≤ D ≤ 35 mm). Nu increased and TEF decreased in increasing of Re. The TEF and Nu increased with closing to channel phase shift angle 90˚, the best performance was noticed on phase shift, ϕ=90º. At the end of this paper effect of distance between chevron surfaces presented, The TEF and Nu increased with decreasing to channel distance and the best performance was noticed on closing to D=5(mm).
Źródło:
Journal of Theoretical and Applied Mechanics; 2018, 56, 3; 751-763
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal efficiency and hydraulic performance evaluation on Ag–Al2O3 and SiC–Al2O3 hybrid nanofluid for circular jet impingement
Autorzy:
Datta, Abanti
Halder, Pabitra
Powiązania:
https://bibliotekanauki.pl/articles/1845498.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hybrid nanofluid
thermal performance factor
pumping power
merit number
Opis:
Hybrid nanofluids is obtained by dispersing more than one nanoparticle into a base fluid. The work is concerned with a detailed numerical investigation of the thermal efficiency and hydraulic performance of hybrid nanofluids for circular jet impinges on a round plate. For this paper, a metal (Ag), a metal oxides (Al2O3) and a metal carbides (SiC) nanoparticle and their water based hybrid nanofluids are considered to analyse numerically with varying significant dimensionless parameters, i.e., the jet-to-plate spacing ratio, Reynolds number and volume fraction of nanoparticles. The results demonstrated that the efficiency of heat transfer of all nanofluids is increased by the addition of nanoparticle to the dispersed in water at constant Reynolds number. Moreover, the results illustrate that heat transfer efficacy and pumping power penalty both increased as jet-to-plate spacing ratio reduced. The jet-to-plate spacing ratio equal to 4 is the best as the percentage enhance heat transfer is maximum in this situation. Since both the heat transfer effect and pumping penalty increase using hybrid nanofluids, thermal performance factor increases or decreases depends on nanoparticles of nanofluids. It is evident that the analysis of these hybrid nanofluids will consider both the increase in heat efficiency and the pumping capacity. The best flow behaviour is achieved for SiC–Al2O3 hybrid nanofluids. New merit number is introduced for additional clarification.
Źródło:
Archives of Thermodynamics; 2021, 42, 1; 163-182
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Induction of multi-nucleate microspores in anther culture of salix viminalis L.
Autorzy:
Wojciechowicz, M K
Kikowska, M.A.
Powiązania:
https://bibliotekanauki.pl/articles/41619.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Dendrologii PAN
Tematy:
Salix viminalis
genotype
androgenesis
thermal factor
medium composition
stress response
thermal shock
anther culture
multinucleate microspore
male clone
mannitol
Kyo medium
microspore
ultrastructural analysis
initial microspore
Opis:
The aim of the work was to determine how the induction of androgenesis in selected genotypes of Salix viminalis is affected by thermal factors and medium composition. Anthers isolated from male clones of S. viminalis were pre-cultured at 4, 27 and 32°C for two to eight days in liquid Kyo medium with and without the addition of mannitol and on solid MS or WPM medium. The solid media were supplemented with different concentration of disaccharidesand various combinations of growth regulators including kinetin, 2iP, IAA and IBA. Multi-nucleate microspores indicative of androgenesis were observed in anthers pre-cultured for seven days at 4°C in liquid Kyo medium containing mannitol. The rate of androgenesis was higher when the anthers were transferred to solid modified MS medium containing high concentrations of sucrose and kinetin. In studied genotypes of basket willow early uninucleate microspores underwent sporophytic divisions. Ultrastructural observations showed differences in cellular arrangement of pre-stressed microspores. In Salix viminalis, microspores without starch grains and decreased number of lipid bodies were potentially androgenic cells.
Źródło:
Dendrobiology; 2009, 61; 55-64
1641-1307
Pojawia się w:
Dendrobiology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of thermal performance factor for solar air heaters with artificially roughened channels
Autorzy:
Siddique, Waseem
Raheem, Aneeq
Aqeel, Muhammad
Qayyum, Sualeh
Salamen, Tareq
Waheed, Khalid
Qureshi, Kamran
Powiązania:
https://bibliotekanauki.pl/articles/1845043.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
turbulence promoter
solar air heater
heat transfer enhancement
thermal performance factor
słoneczny grzejnik powietrzny
intensyfikacja wymiany ciepła
współczynnik wydajności cieplnej
Opis:
Heat transfer augmentation has become the utmost industrial desire. Turbulence promoters seems to be a better option for better heat transfer but at the expense of enormous pressure drop. In the current study, experimental optimization of heat transfer and pressure drop in various configurations of ribbed and corrugated surfaces on the bottom wall of the Solar Air Heater channel, having aspect ratio of 26:5 was performed. The results were evaluated in terms of enhancement in heat transfer (Nu/Nu s), friction factor ratio (f/f s) and thermal performance factor ( η). Three different cases and nine configurations with a pitch to rib/corrugation height ratio of 4.0 were studied. Case A consists of a smooth, continuous square rib, inline and staggered broken ribs. Case B comprises 30°, 45°, 60° and 90° trapezoidal corrugated geometries while Case C is the comparison of smooth, wavy corrugated and the best configurations of cases A and B. The results show that rectangular duct with staggered broken ribs and trapezoidal corrugation at 45° are the best configurations for case A and B, respectively. The 45° corrugated configuration is the best one amongst all, with values of 1.53, 1.5 and 1.33% for Nu/Nu s, f/f s and η respectively.
Źródło:
Archive of Mechanical Engineering; 2021, LXVIII, 2; 195-225
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody arkhitekturno-stroitel'nykh reshenijj teplovaja effektivnost' zdanijj
Methods of architectural and construction solutions and thermal effectiveness of buildings
Autorzy:
Kulikov, G.
Kaz'mina, A.
Powiązania:
https://bibliotekanauki.pl/articles/77512.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
thermal effectiveness
solar energy
climatic factor
building parameter
microclimate
thermal power
thermal balance
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the stress intensity factors for transient thermal loading in an orthotropic thin plate with a crack
O współczynnikach intensywności naprężenia dla nieustalonego termicznego obciążenia w ortotropowej cienkiej płycie ze szczeliną
Autorzy:
Rogowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/281915.pdf
Data publikacji:
2004
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
orthotropic plate
crack problem
transient thermal loading
stress intensity factor
Opis:
This paper is concerned with an orthotropic thin plate containing a crack perpendicular to its surfaces. It is assumed that the transient thermal stress is set up by the application of a heat flux as a function of time and position along the crack edge and the heat flow by convection from the plate surfaces. The exact analytical solutions for the stress intensity factor and crack-opening displacement are derived. Numerical examples show, among others, a dependence of the stress intensity factor on the thermal and elastic constants of the orthotropic material.
Rozpatrzono zagadnienie ortotropowej cienkiej płyty zawierającej szczelinę prostopadłą do jej brzegów. Założono, że nieustalone naprężenia termiczne powstają w wyniku przepływu przez powierzchnie szczeliny strumienia ciepła będącego funkcją czasu, miejsca i konwekcyjnego przepływu ciepła przez powierzchnie płyty. Znaleziono ścisłe, analityczne rozwiązanie określające współczynnik intensywności naprężeń i rozwarcie szczeliny. Przykłady numeryczne pokazują zależności temperatury, naprężeń i współczynnika intensywności naprężenia od parametrów geometrycznych i stałych określających własności termiczne i sprężyste materiału.
Źródło:
Journal of Theoretical and Applied Mechanics; 2004, 42, 4; 739-753
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigation of augmented thermal and performance characteristics of solar air heater ducts due to varied orientations of roughness geometry on the absorber plate
Autorzy:
Sahu, Mukesh Kumar
Matheswaran, M. M.
Bishnoi, Pardeep
Powiązania:
https://bibliotekanauki.pl/articles/239981.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
solar air heater
SAH
thermal efficiency
heat removal factor
collector efficiency factor
artificial roughness
heat transfer rate
Opis:
This paper presents the outdoor experimental results for thermal performance analysis of artificially roughened solar air heaters (SAHs). Circular wire ribs have been arranged to form arc shape geometry on the absorber plates and have been tested for two configurations of SAHs named as arc shape apex-downstream flow and arc shape apex-upstream flow SAH. Roughness parameters have been taken as relative roughness pitch in the range of 8–15, angle of attack 45°–75°, and for fixed relative roughness height of 0.0454, duct width to duct height ratio of 11. During the experimental analysis the mass flow rate varied from 0.0100 to 0.0471 kg/s. Based on the experimental results it was found that roughness with apexupstream flow SAH is having higher value of thermal efficiency, heat removal factor and collector efficiency factor as compared to roughness with apexdownstream flow SAH and simple absorber plate SAH. In the range of the operating parameters investigated the maximum of thermal efficiency, heat removal factor, and collector efficiency factor have been found.
Źródło:
Archives of Thermodynamics; 2020, 41, 3; 147-182
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature dependent electrical characteristics of Nichrome/4H-SiC Schottky barrier diodes
Autorzy:
Khanna, Shaweta
Noor, A.
Powiązania:
https://bibliotekanauki.pl/articles/1076274.pdf
Data publikacji:
2019
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Nichrome
Schottky Diodes
Schottky barrier height
ideality factor
rapid thermal annealing
Opis:
Nichrome Schottky barrier diodes have been fabricated on 4H-SiC substrates to investigate the temperature dependant electrical characteristics of the fabricated contacts. The electrical parameters such as barrier height, ideality factor and donor concentration were found from the current-voltage (I-V) and the capacitance-voltage (C-V) measurements at room temperature. Barrier Contacts showed non-ideal behaviour like lower value of barrier height and high value of ideality factor. A barrier height of 1.53eV obtained from C-V measurements and 0.79eV obtained from the I-V measurements with ideality factor of 1.96 for as-deposited diodes at room temperature. The diodes, therefore, were annealed in the temperature range from 25-400 ºC to see the effect of annealing temperature on these parameters. Schottky barrier height (SBH) and ideality factors were found temperature dependent. After rapid thermal annealing (RTA) upto 400 ºC barrier height of 1.27 eV from C-V measurements and the value of 1.13 eV were obtained from I-V measurements with ideality factor of 1.12. Since barrier height deduced from C-V measurements were consistently larger than those from I-V measurements. To remove this discrepancy we re-examined our results by including the effect of ideality factor in the expression of the saturation current. The insertion of ideality factor results in comparably good agreement between the values of barrier height derived by above two methods. We believe that the enhancement in the electrical parameters result from the improvement in the quality of interfacial layer.
Źródło:
World Scientific News; 2019, 116; 169-179
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computation of SIFs for cracked FGMs under mechanical and thermal loadings
Autorzy:
Ait Ferhat, Yazid
Boulenouar, Abdelkader
Powiązania:
https://bibliotekanauki.pl/articles/2065775.pdf
Data publikacji:
2020
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
functionally graded materials
stress intensity factor
displacement extrapolation
thermal loading
finite element
Opis:
The objective of this study is to present a numerical modeling of mixed-mode fracture in isotropic functionally graded materials (FGMs), under mechanical and thermal loading conditions. In this paper, a modified displacement extrapolation technique (DET) was proposed to calculate the stress intensity factor (SIFs) for isotropic FGMs. Using the Ansys Parametric Design Language APDL, the continuous variations of the material properties are incorporated by specified parameters at the centroid of each element. Three numerical examples are presented to evaluate the accuracy of SIFs calculated by the proposed method. Comparisons have been made between the SIFs predicted by the DET and the available reference solutions in the current literature. A good agreement is obtained between the results of the DET and the reference solutions.
Źródło:
Archives of Mechanical Technology and Materials; 2020, 40; 12--19
2450-9469
Pojawia się w:
Archives of Mechanical Technology and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Adjustable Thermal Insulations of Tibetan Clothing by Manikin Testing
Ocena możliwości zmian izolacji cieplnej ubiorów tybetańskich przy wykorzystaniu manekina
Autorzy:
Guo, X F
Wang, Y Y
Li, J
Powiązania:
https://bibliotekanauki.pl/articles/232266.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
Tibetan clothing
style
thermal insulation
clothing area factor
thermal manikin
ubiór tybetański
styl
izolacja cieplna
przewodzenie ciepła
manekin termiczny
Opis:
The thermal insulation of clothing needs to be easily adjusted in an unsteady environment, but this is extremely difficult for most clothing. To reveal the effect of different styles of Tibetan clothing on their thermal property, the total thermal insulations of Tibetan clothing in three typical styles were measured using a thermal manikin. The clothing area factors (fcl) of the Tibetan clothing and body surface area covered by a Tibetan robe were tested with a photographic method. The results showed the following: 1) For similar insulation, fcl of Tibetan clothing is about 0.23 bigger than that of western clothing, estimated from ISO 11079; 2)the style of Tibetan clothing significantly affects the fcl (p < 0.05, fcl = 1.229 + 0.007 BSAC) and the intrinsic thermal insulation (p < 0.05, Icl = 0.166 + 0.016 BSAC); 3)the adjustable thermal insulation of Tibetan clothing proved its adaptability to the large air temperature difference environment on the Tibetan plateau ,which should be valuable for the product development of clothing used in a unsteady environment.
Odzież powinna umożliwiać zmianę jej przewodności cieplnej w niestabilnym środowisku, jednak dla większości odzieży jest to niezwykle trudne. W celu określenia wpływu różnych stylów ubiorów tybetańskich na ich właściwości termiczne określono całkowitą izolację termiczna dla trzech typowych stylów odzieży tybetańskiej przy zastosowaniu manekina termicznego. Wpływ konfiguracji ubioru sprawdzono metodą fotograficzną za pomocą termowizji, określając jednocześnie powierzchniowy współczynnik okrycia ciała fcl. Wykazano, że 1) przy podobnej izolacji fcl ubiorów tybetańskich jest o 0.23 większy od ubiorów zachodnich (ISO11079); 2) styl ubiorów tybetańskich znacząco wpływa na fcl jak i wewnętrzną izolacje cieplną; 3) możliwość regulacji izolacji termicznej tybetańskiego ubioru zapewnia zdolność przystosowania się do dużych różnic temperatury otoczenia na płaskowyżu tybetańskim. Wyniki badań mogą znaleźć zastosowanie w projektowaniu odzieży noszonej w niestabilnym środowisku.
Źródło:
Fibres & Textiles in Eastern Europe; 2013, 1 (97); 87-91
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zagrożeń środowiska pracy w elektrowniach cieplnych-węglowych
Analysis of work environment hazards at the thermal power plants – coal-based
Autorzy:
Bajdur, W.M.
Mrówczyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/103688.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
czynniki chemiczne
czynniki fizyczne
czynniki psychofizyczne
elektrownie cieplne
eliminacja zagrożeń
chemical factor
physical factor
psychophysical factors
thermal power plants
hazards elimination
Opis:
Jednym z najważniejszych zagadnień dotyczących środowiska pracy jest identyfikacja i analiza zagrożeń. Zagrożenia określamy na podstawie pomiaru częstości i ilości różnorodnych czynników występujących w środowisku pracy. Pracodawca wskazuje czynniki szkodliwe po przeprowadzeniu rozpoznania źródeł emisji oraz warunków wykonywania pracy, które mają wpływ na poziom stężeń lub natężeń tych czynników lub na poziom narażenia na oddziaływanie tychże. W elektrowniach cieplnych produkujących energię elektryczną z paliw kopalnych (węgiel) prowadzi się badania i pomiary praktycznie większości czynników z grup czynników fizycznych i chemicznych, na które może być narażony pracownik w środowisku pracy. W artykule przedstawiono identyfikację zagrożeń w elektrowni cieplnej i dokonano ich analizy z uwzględnieniem metod eliminacji tych zagrożeń.
One of the most essential issue regarding work environment is identification and analysis of hazards. Hazards are defined based on measurement of frequency and number of various factors occurring at the work environment. The employer specifies harmful factors after recognizing sources of emission and work conditions, which influence levels of concentrations or intensity of the mentioned factors, or level of exposure to the mentioned factors. Tests and measurements of practically all physical and chemical factors, to which the worker at the work environment may be exposed, are carried out in thermal power plants which generate electric energy of fossil fuels (coal). The article covers identification of hazards at the thermal power plant and their analysis considering methods of their elimination.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2016, T. 4; 13-23
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ współczynnika kształtu A/V na wielkość strat ciepła w budynku w świetle rosnących wymogów dotyczących izolacyjności termicznej przegród budowlanych
Influence of building’s shape factor on its heat losses with respect to increasing requirements for building’s thermal insulation
Autorzy:
Kaczmarzyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/104841.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
współczynnik kształtu A/V
izolacyjność termiczna
straty ciepła
obudowa termiczna budynku
A/V shape factor
thermal insulation
heat losses
building’s thermal envelope
Opis:
Celem niniejszego artykułu było określenie jaki faktyczny wpływ na wielkość sezonowych strat ciepła przez obudowę termiczną budynku miało kiedyś i może mieć obecnie zachowanie zwartej bryły budynku. W artykule przybliżono pojęcia izolacyjności termicznej i współczynnika przenikania ciepła przegród budowlanych. Przedstawiono tu także krajowe wymogi dotyczące izolacyjności termicznej przegród budowlanych, jakie obowiązywały w minionych dekadach, jakie obowiązują obecnie i te, które będą stawiane wobec przegród budowlanych w najbliższych latach. Wyjaśniono także, czym dla budynku jest współczynnik kształtu A/V i powód, dla którego kształt bryły budynku może wpływać na jego charakterystykę energetyczną. Zaprezentowano wnioski sformułowane przez innych autorów, których prace dotyczą optymalizacji kształtu bryły budynku pod względem cieplnym. Przytoczono również krytyczne opinie dotyczące wpływu takiej optymalizacji kształtu na atrakcyjność architektury obiektów budowlanych. Metodę badawczą oparto na obliczeniach sezonowych strat ciepła w budynkach o różnych stosunkach powierzchni przegród zewnętrznych do kubatury budynku A/V. Obliczenia przeprowadzono dla 27 modeli budynków o identycznej powierzchni wewnętrznej i kubaturze wewnętrznej, lecz różniących się proporcjami wymiarów i liczbą kondygnacji. W obliczeniach wzięto pod uwagę dziewięć zestawów wartości współczynników przenikania ciepła przegród zewnętrznych, odpowiadających dawnym, aktualnym i przyszłym wymogom krajowym. Różnice w wartościach sezonowych strat ciepła uzyskane dla każdego z zestawów zinterpretowano jako potencjalne oszczędności energetyczne, wynikające z zachowania zwartej bryły budynku i ograniczenia wartości współczynnika kształtu A/V. Wyniki zestawiono i na ich podstawie sformułowano stosowne wnioski.
The purpose of this paper was to determine former, current and future impact of building’s shape compactness on its heat losses. The article explains such terms as thermal insulation and heat transfer coefficient of building barrier’s, as well as the history of Polish national regulations concerning that subject. It was also explained, what building shape factor is, and what may be its potential impact on building’s efficient Energy use. The paper presented conclusions of numerous research on building shape optimization, including critical opinions about architectural effects of the process. The scientific method was based on calculations of seasonal heat losses in multiple buildings varying with their volume to Surface area ratio. Calculations were conducted for twenty seven buildings of the same floor Surface area and interior volume, but of different proportions and number of storeys. Calculations considered nine groups of heat transfer coefficient values for building barriers, that corresponded to former, current and future standards, established by polish regulations Differences in acquired values of seasonal heat loses were interpreted as potential energy savings to be obtained by applying thermal envelopes with low shape factors. Presented results have been compared and basing on them, final conclusions were formed.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 2/II; 45-54
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of selected factors on sensory quality of pork
Wpływ wybranych czynników warunkujących jakość sensoryczną wieprzowiny
Autorzy:
Jaworska, D.
Przybylski, W.
Powiązania:
https://bibliotekanauki.pl/articles/826470.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Technologów Żywności
Tematy:
pork
sensory quality
pork quality
selected factor
intramuscular fat
pH
calpastatin gene
raw material quality
thermal process
Opis:
This manuscript presents results of authors` research regarding selected factors influencing sensory pork quality. In the manuscript the role of breed, genes (RYR1T, RN-, CAST), slaughter weight as well as meatiness is comprised. Additionally, the role of intramuscular fat, ultimate pH and heat treatment on pork quality is discussed. It was stated that the optimization of the sensory aspects of the pork quality should not be limited to one aspect only but it should include the practical use of a number of dependent determinants. Obtaining high eating quality depends also on the quality of the raw material and the way of thermal processes (temperature, time, method of thermal process).
W pracy przedstawiono wybrane wyniki badań autorów pracy w zakresie wybranych czynników determinujących sensoryczną jakość wieprzowiny. Zamieszczono charakterystykę wpływu rasy, genów (RYR1T, RN- i CAST), masy tuszy, mięsności w odniesieniu do jakości sensorycznej mięsa. Omówiono wpływ zawartości tłuszczu śródmięśniowego, wartości pH, warunków obróbki cieplnej na jakość mięsa. Stwierdzono, że optymalizacja sensorycznych cech jakości mięsa nie powinna być traktowana jednokierunkowo, powinna obejmować praktyczne wykorzystanie szeregu wzajemnie powiązanych determinantów. Otrzymanie mięsa kulinarnego wysokiej jakości jest uzależnione także od jakości surowca oraz od sposobu prowadzenia procesów cieplnych (temperatura, czas, metoda).
Źródło:
Żywność Nauka Technologia Jakość; 2014, 21, 5
1425-6959
Pojawia się w:
Żywność Nauka Technologia Jakość
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies