Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tap water" wg kryterium: Temat


Wyświetlanie 1-42 z 42
Tytuł:
Environmental factors affecting the survival of soil dwelling Legionella longbeachae in water
Autorzy:
Potočnjak, Mia
Magdalenić, Zlatko
Dijan, Marija
Rebić, Danica
Gobin, Ivana
Powiązania:
https://bibliotekanauki.pl/articles/990884.pdf
Data publikacji:
2016
Wydawca:
Instytut Medycyny Wsi
Tematy:
legionella
survival
stagnant tap water
temperature
Opis:
Introduction. Legionella longbeachae, a causative agent of Legionnaire’s disease, has often been associated with potting soil and gardening, a feature quite distinct from other Legionella species. The precise transmission mechanism is still unknown, although due to the ecological coherence of the soil and water there is a potential risk of infection by contaminated stagnant water in the garden. Objective. The aim of the study was to explore the ability of L. longbeachae to survive in stagnant tap water usually used for watering in gardens. The influence of different factors (temperature, pH and NaCl concentration) on L. longbeachae survival in stagnant tap water was also tested. Results. The result showed that L. longbeachae is viable in stagnant tap water over 100 days at 4 °C and 25 °C. The survival of L. longbeachae exposed to different pH and NaCl concentration suggests resistance to low pH values (pH2 and pH5) and all tested NaCl concentrations at temperatures lower than 25 °C. The ability of L. longbeachae to persist in stagnant tap water should be taken seriously in the risk assessments as a possible hidden reservoir of infection.
Źródło:
Annals of Agricultural and Environmental Medicine; 2016, 23, 3
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemistry of tap water in selected localities on South Podlasie Lowland
Chemizm wody wodociągowej w wybranych miejscowościach niziny południowopodlaskiej
Autorzy:
Kalembasa, D.
Jaremko, D.
Becher, M.
Pakuła, K.
Stefański, K.
Powiązania:
https://bibliotekanauki.pl/articles/125944.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
tap water chemistry
ICP-AES
quality indicators of tap water
chemizm wody wodociągowej
wskaźniki jakości wody wodociągowej
Opis:
The aim of this paper is presentation of results of chemical composition of tap water in selected localities on South Podlasie Lowland. Samples of water were taken from water treatment station and taps situated in various parts of Lukow, Sokolow Podlaski and selected localities in Lochow, Wierzbno and Mokobody commune. Quarterly investigations covered analysis of water reaction (pH) by potentiometric method, electrical conductivity (EC) by electrochemical method and total concentration of 26 elements by inductively coupled plasma atomic emission spectrometry (ICP-AES). It was found that untreated waters being the source of tap water in selected localities on South Podlasie Lowland contained excessive iron and manganese amounts, that were efficiently removed during the treatment. Concentration of analyzed elements in treated water did not exceed the permissible limits and quality of analyzed tap water changed a little during its transport due to the secondary contamination.
Celem niniejszej pracy jest przedstawienie wyników analizy składu chemicznego wody wodociągowej dostarczanej mieszkańcom wybranych miejscowości Niziny Południowopodlaskiej. Punkty pobrania próbek do badań wyznaczono na wyjściu ze stacji uzdatniania oraz w kurkach czerpalnych, położonych w różnych dzielnicach Łukowa i Sokołowa Podlaskiego, a także w różnych miejscowościach gmin Łochów, Wierzbno i Mokobody. Próbki wody pobierano w odstępach kwartalnych. W pobranych próbkach oznaczono odczyn (pH) wody metodą potencjometryczną, przewodnictwo właściwe metodą elektrochemiczną oraz stężenie K, Ca, Mg, Na, S, Fe, Mn, B, Li, Ba, Sr, Cu, Zn, Ni metodą optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie sprzężonej indukcyjnie (ICP-AES). Stężenie pierwiastków objętych badaniami na ogół nie przekraczało obowiązujących wartości dopuszczalnych. Sporadycznie odnotowano podwyższone wartości analizowanych parametrów w próbkach wody pobieranych w kurkach czerpalnych, wskazujące na zanieczyszczenie wody w systemie dystrybucji. W wodzie surowej stwierdzono ponadnormatywne stężenia żelaza i manganu, ale pierwiastki te były skutecznie usuwane w procesie uzdatniania.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 523-528
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acanthamoeba in the Domestic Water Supply of Huntington, West Virginia, U.S.A.
Autorzy:
Trzyna, Wendy
Mbugua, Margaret W.
Rogerson, Andrew
Powiązania:
https://bibliotekanauki.pl/articles/763579.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Jagielloński. Wydawnictwo Uniwersytetu Jagiellońskiego
Tematy:
Amoebic Keratitis, amoebae, tap water, Acanthamoeba, chlorine tolerance
Opis:
The aim of this study was to determine the prevalence of Acanthamoeba in the domestic water supply in Huntington, West Virginia (U.S.A.) and the factors that may contribute to their presence or absence. One hundred sixty-two one liter tap water samples were collected over eight months. Amoebae in the samples (cysts or trophozoites) were harvested by passively filtering onto 5 μm pore size filters and enriching for amoebae on non-nutrient amoeba saline agar plates seeded with Escherichia coli for cultivation. Thirteen percent of all samples were positive for amoebae and 9.3% were positive for the amoeba of interest, Acanthamoeba. Chlorine levels were determined for samples at the time of collection, yielding a mean level of 1.56 mg l–1 chlorine in the distribution system ca. 8 kilometers from the water treatment plant. Cysts and trophozoites of Acanthamoeba clonal isolates were found to tolerate up to 50 mg l–1 and 4 mg l–1 chlorine respectively. This study showed that Acanthamoeba were present in the domestic water supply in Huntington, WV and although no attempt was made to count cells in liter samples, their frequency of occurrence (9.3%) and failure to be present in all replicates, suggests they were present at background levels of perhaps a few cells per five liters. This is only the second U.S. study to consider amoebae in tap water and is unique since the source water was river water. Acanthamoeba trophozoites and cysts were able to withstand levels of chlorine higher than those typically found in tap water suggesting they may be present in either form in the distribution system. Acanthamoeba are opportunistic pathogens capable of causing eye infections and their presence in tap water is a potential risk factor for susceptible individuals, particularly contact lens wearers who may use tap water to clean lenses and storage cases.
Źródło:
Acta Protozoologica; 2010, 49, 1
1689-0027
Pojawia się w:
Acta Protozoologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mętność wody dostarczanej przez systemy wodociągowe województwa małopolskiego.
Turbidity of water provided by the water supply systems in the Malopolskie Voivodeship.
Autorzy:
Bergel, T.
Pawełek, J.
Rułka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/236546.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
jakość wody
mętność
tap water
water quality
turbidity
Opis:
W pracy dokonano analizy mętności wody dostarczonej odbiorcom w 2007 r. przez systemy wodociągowe w województwie małopolskim. W analizie uwzględniono wszystkie zakłady wodociągowe, które są objęte monitoringiem kontrolnym i przeglądowym przez wojewódzkie służby sanitarno-epidemiologiczne - łącznie 703. W badaniach obejmujących analizę 1794 próbek wody, w tym 167 próbek wody powierzchniowej, 1261 - wody podziemnej i 366 - wody mieszanej, określono mętność minimalną, maksymalną i średnią oraz liczbę przekroczeń mętności dopuszczalnej (1 NTU). Przeprowadzona analiza wykazała, że mętność wody wodociągowej, w zależności od źródła wody, wynosiła: wody powierzchniowe 0,1÷8,7 NTU (śr. 0,97 NTU), wody podziemne 0,01÷26,0 NTU (śr. 0,84 NTU), wody mieszane 0,02÷10,0 NTU (śr. 0,93 NTU). Najwięcej przekroczeń mętności dopuszczalnej odnotowano w wodociągach korzystających z wód powierzchniowych - 29,3% analizowanych próbek, a znacznie mniej w korzystających z wód podziemnych - 12,4% i mieszanych - 4,1%. Przekroczenia te w przeważającej większości przypadków mieściły się w przedziale 1÷5 NTU.
The water supplied to the users in the Malopolskie Voivodeship in 2007 was analyzed for turbidity. The analysis covered 703 waterworks regularly monitored by the Regional Sanitary and Epidemiological Station. A total of 1794 water samples was made subject to analysis (167 surface water samples, 1261 groundwater samples and 366 mixed water samples) to determine the minimal, maximal and average turbidity levels, as well as the number of episodes when the admissible turbidity value (1 NTU) was exceeded. The study has produced the following findings. According to the water source being used, the turbidity of the tap water supplied varied from 0.1 to 8.7 NTU (av. 0.97 NTU) for surface water, from 0.01 to 26.0 NTU (av. 0.84 NTU) for groundwater, and from 0.02 to 10.0 NTU (av. 0.93 NTU) for mixed water. The majority of episodes with the 1 NTU value being exceeded were observed in the waterworks using surface water (29.3% of samples). Significantly lower was the number of such episodes in the waterworks where use was made of groundwater (12.4% of samples) or mixed water (4.1% of samples). In most instances the exceeded turbidity values were within the range of 1 to 5 NTU.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 61-64
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie heterotroficznych bakterii z rodzaju Aeromonas w wybranym systemie dystrybucji wody
Occurrence of heterotrophic bacteria of the genus Aeromonas in a water distribution system: A case study
Autorzy:
Kręgiel, D.
Rygała, A.
Powiązania:
https://bibliotekanauki.pl/articles/237313.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
biofilm
adhezja
luminometria
tap water
adhesion
luminometry
Opis:
Hetrotroficzne bakterie Aeromomas sp występują powszechnie w środowisku wodnym, a niektóre z nich są patogenami dla ludzi i ryb. Występowanie bakterii Aeromonas hydrophila badano w systemie dystrybucji wody podziemnej, nie poddanej chlorowaniu. Badania przeprowadzono systematycznie w ciągu całego roku. Stwierdzono, że bakterie z rodzaju Aeromonas były wykrywane w wodzie wodociągowej w miesiącach letnich, od maja do października, przy czym największy wzrost liczby bakterii wynoszący 156 jtk/100 cm3 odnotowano w sierpniu. Około 80% wyizolowanych szczepów, wykazujących zdolność [beta]-hemolizy, zidentyfikowano jako Aeromonas hydrophila. Wyizolowane bakterie adherowały do powierzchni PVC, materiału powszechnie stosowanego w instalacjach wodociągowych. Biorąc pod uwagę zarówno silne właściwości adhezyjne Aeromonas sp., które stymulują tworzenie biofilmu, jak i możliwość występowania różnych czynników wirulencji warunkujących ich chorobotwórczość, należy rozważyć włączenie pałeczek z rodzaju Aeromonas do rutynowych badań mikrobiologicznych wody, a zwłaszcza do monitoringu funkcjonowania sieci i urządzeń wodociągowych.
Heterotrophic strains of Aeromonas sp. are ubiquitous in aquatic environments, but some of them have a pathogenic impact on humans and fish. Samples were taken regularly over a one-year period from a system distributing unchlorinated groundwater, which was analyzed for the presence of Aeromonas hydrophila. Bacteria of the genus Aeromonas were detected in tap water samples collected from May to October, the largest increase in the number of these bacteria (156 cfu/100 cm3) being observed in August. Approximately 80% of the isolated strains, with a capacity for [beta]-hemolysis, were identified as Aeromonas hydrophila. The bacteria showed the ability to adhere to the surface of PVC, a material widely used in water-supply systems. Taking into account, on the one hand, the strong adhesion properties of Aeromonas sp., which stimulate biofilm formation, and considering, on the other hand, the occurrence of various virulence factors that underlie the pathogenicity of Aeromonas sp., it seems recommendable to include rods of the genus Aeromonas not only into routine microbiological analysis of tap water, but also into the monitoring of the functioning of water distribution systems.
Źródło:
Ochrona Środowiska; 2010, 32, 4; 47-50
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Natural radioactivity in tap water samples for selected regions in Thi-Qar Governorate - Iraq
Autorzy:
Hadi, Hasan A.
Karim, Mahmood S.
Mahi, Ali T.
Abood, Tareq H.
Powiązania:
https://bibliotekanauki.pl/articles/1192660.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
(HPGe) detector
Thi-Qar governorate
tap water
specific activity
radionuclides
Opis:
In the present work, we have measured specific activity concentrations in ten tap water samples for selected regions in Thi-Qar governorate by using high purity germanium (HPGe) detector. The results have shown that, the specific activity, for 238U was ranged from (0.65±0.8 Bq/kg) in AL- Nasir region to (1.32±0.7.8 Bq/kg) in AL-Refai region, for 232Th the specific activity was ranged from (0.120±0.34 Bq/kg) in AL-Garraf region to (0.980±0.99 Bq/kg) in AL- Dwaya region, for 40K the specific activity was ranged from (13.33±3.6 Bq/kg) in AL-Nasir region to (38.54±6.2 Bq/kg) in (AL-Garraf) region, with an average values of (0.933±0.16 Bq/kg), (0.737±0.17 Bq/kg), (24.451±7.5Bq/kg), for 238U, 232Th and 40K, respectively. In order to asses the radiological hazards of the radioactivity in tap water, we have been calculated the parameters (Raeq , DƔ, AEDin , AEDout , EAD , Iɣ , Hin and Hex).
Źródło:
World Scientific News; 2016, 47, 2; 112-122
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamics of water consumption changes in a tourist resort
Autorzy:
Bartkowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/125041.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
indicators
tap water
variation trends
water consumption
water requirement index
water supply system
Opis:
This work presents problems related to the water consumption in the city of Olecko situated in the north-east part of Poland in the Warmińsko-Mazurskie Province of the country, at the eastern border of the Mazurian Lake District along the trail connecting the land of the Large Mazurian Lakes with the Suwalsko-Augustowskie Lake District. Over 2011–2012 water extraction to the municipal water supply network was studied. The volume of water extracted every day was analyzed and the gathered volumes were analyzed statistically. The varying water extraction was also studied. The obtained results were presented in a graphic form. Basing on the descriptive stats and prepared diagrams certain general conclusions were drawn and the collected study figures and facts were summed up. This allowed to determine days of the highest and lowest water consumption. Also months of extreme water extraction and consumption were determined. The water extraction ranged from 1641 m3/24h to 2607 m3/24h, at an average value of 2077.4 m3/24h. Over the period under study the day of the largest water extraction and consumption was in July and the day of the lowest water extraction and consumption in December. During a week inhabitants used the highest water amount on Saturdays and the lowest on Sundays and other feast-days. Basing on the conducted measurements also the coefficient of water consumption per capita was determined. The fluctuation of this coefficient was identical as that for the water consumption. Within the period of study it ranged from 73.3 l/M 24h to 116.5 l/M 24h. The average value of the specific water consumption was 92.8 l/M 24h. For the sake of discussion the obtained results were compared with observations across the country.
Źródło:
Journal of Ecological Engineering; 2014, 15, 4; 46-54
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skutki braku stabilności biologicznej wody wodociągowej
Lack of Biological Stability and the Implication it has for Tap Water Quality
Autorzy:
Świderska-Bróż, M.
Powiązania:
https://bibliotekanauki.pl/articles/236444.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
stabilność biologiczna
biofilm
tap water quality
biological stability
Opis:
Omówiono parametry składu wody oraz procesy oczyszczania współdecydujące o jej biologicznej stabilności. Wykazano, że brak stabilności biologicznej wody wprowadzanej do sieci wodociągowej jest jedną z głównych przyczyn wtórnego fizyczno-chemicznego i bakteriologicznego zanieczyszczenia wody wodociągowej podczas jej transportu do odbiorców. Wykazano, że w wodzie niestabilnej biologicznie przebiegają takie zjawiska, jak wtórny rozwój mikroorganizmów unoszonych z wodą lub zasiedlających wewnętrzne powierzchnie przewodów wodociągowych (tzw. biofilm), biokorozja intensyfikująca korozję elektrochemiczną metali, hamowanie powstawania powłok antykorozyjnych, bądź ich rozpuszczanie, zwiększone zużycie środków dezynfekcyjnych i uwalnianie produktów korozji metali do wody. Zjawiska te są powodem wtórnego zanieczyszczenia wody podczas jej przebywania w systemie wodociągowym.
The parameters of the water composition and the treatment processes contributing to its biological stability are specified. It has been shown that the lack of biological stability of the water entering the pipe network is one the major factors responsible for the recontamination (both physicochemical and bacteriological) of the tap water during transport to the users. Biologically unstable water favours the occurrence of the following phenomena: regrowth of microorganisms floating in the water or colonizing the pipe interior (biofilm), biocorrosion enhancing the electrochemical corrosion of metals, inhibition of anticorrosive film formation, solubilization of anticorrosive films, release of metal corrosion products into the water, etc. They all are contributions to the recontamination of water during residence in the water supply system.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 7-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of using borehole heat exchangers in Macedonia and in Poland
Autorzy:
Kowalski, T.
Ruvceska, A.
Śliwa, T.
Bieda, A.
Powiązania:
https://bibliotekanauki.pl/articles/298667.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
borehole heat exchangers
geothermal energy
heat pump
hot tap water
Opis:
Using borehole heat exchangers for heating and cooling in different climate conditions were analysed and compared in this paper, considering the heating and cooling modes of the heat pump. Economic analysis were made according to the energy demand for heating, cooling and hot tap water with borehole heat exchangers for a typical family house. The costs for running borehole heat exchangers in Macedonia and Poland were also based on the average monthly temperatures and geological profile of the location.
Źródło:
AGH Drilling, Oil, Gas; 2017, 34, 1; 141-156
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem wtórnego zanieczyszczenia wody w województwie śląskim
The problem of secondary pollution of water in the Silesian region
Autorzy:
Puszczało, Ewa
Marszałek, Anna
Powiązania:
https://bibliotekanauki.pl/articles/125872.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
woda wodociągowa
uzdatnianie wody
wtórne zanieczyszczenie
tap water
second water pollution
water treatment
Opis:
Woda z wodociągu pod względem bakteriologicznym oraz chemicznym musi spełniać wymagania stawiane wodzie do picia. Zakłady wodociągowe mają obowiązek stale kontrolować jakość dostarczanej wody. Wyniki badań zamieszczone na stronie Zakładu Wodociągów i Kanalizacji w Gliwicach potwierdzają dobrą jakość wody w Gliwicach. Jednak zanim woda znajdzie się w naszym kranie, przechodzi drogę wodociągami. Gdy na zamieszkiwanym przez nas osiedlu znajdują się stare rury albo mieszkamy w domu, w którym rury nie były wymieniane przez wiele lat, w wodzie mogą pojawiać się szkodliwe związki. Ponadto woda wodociągowa może odznaczać się dużą twardością. Jest to najczęstsza przyczyna powstawiania kamienia, który dodatkowo znacznie obniża smak wody z kranu. Aby poprawić jakość wody wodociągowej, konsumenci stosują urządzenia filtrujące wodę z kranu lub kupują wodę butelkowaną. W artykule przedstawiono badanie ankietowe techniką wyboru przypadkowego na wybranej grupie 200 mieszkańców w średnim wieku w mieście Gliwice w czerwcu 2019 roku. Głównym celem pracy było przedstawienie opinii mieszkańców na temat oczekiwań związanych z poprawą jakości wody z kranu.
In terms of bacteriology and chemistry, the tap water must meet the requirements for drinking water. Water utilities (waterworks) are required to constantly monitor the quality of supplied water. Test results posted on Department of Waterworks and Sewerage in Gliwice website confirm good water quality in Gliwice. However, before the water reaches our tap, it goes through the waterworks. When old pipes are found in the housing estate we live in or we live in a house where pipes have not been changed for many years, harmful compounds may appear in the water. In addition, tap water can be characterized by high hardness. This is the most common cause of stone formation, which further significantly reduces the tap water taste. To improve the quality of tap water, consumers use tap water filtering devices or buy bottled water. This article presents a survey using a random selection technique on a selected group of 200 middle-aged residents in the city of Gliwice in June 2019. The main goal was to present residents' opinions on the need to improve tap water quality.
Źródło:
Proceedings of ECOpole; 2020, 14, 1; 129-134
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skład chemiczny wody w siedleckiej sieci wodociągowej
Chemical composition of drinking water in Siedlce
Autorzy:
Kalembasa, D.
Jaremko, D.
Powiązania:
https://bibliotekanauki.pl/articles/338793.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ICP-AES
makro- i mikroelementy
woda wodociągowa
macro- and microelements
tap water
Opis:
W pracy przedstawiono wyniki badań składu chemicznego wody wodociągowej w mieście Siedlce. Punkty pobierania próbek do badań wyznaczono na wyjściu ze stacji uzdatniania, skąd woda jest kierowana do sieci miejskiej, oraz w 18 kurkach czerpalnych położonych w różnych dzielnicach miasta. Próbki wody pobrano w czterech terminach, w odstępach kwartalnych, w latach 2004/2005. Badano w nich zawartość 26 pierwiastków metodą ICP-AES. Uzyskane dane opracowano statystycznie. Stwierdzono, że jakość wody uzdatnionej przekazywanej do systemu dystrybucji w Siedlcach spełnia wszystkie normy w zakresie wskaźników objętych badaniami. Jej jakość w wyniku wtórnego zanieczyszczenia ulega niewielkiej zmianie w czasie transportu. Nie zaobserwowano znacznych przekroczeń dopuszczalnych stężeń składników mineralnych w próbkach wody, a niewielkie ponadnormatywne ilości wystąpiły w małej liczbie analizowanych próbek.
Results of chemical analyses of the tap water in Siedlce are presented in this paper Samples of water were taken from water treatment station and from eighteen taps situated in various parts of the town. Quarterly investigations included analysis of total concentrations of twenty six elements by inductively coupled plasma atomic emission spectrometry (ICP-AES). The resulting data were processed statistically. It was found that treated water in Siedlce water supply system meets the requirements for drinking water. Quality of water slightly worsens during transport due to secondary contamination, but this happened sporadically.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2008, T. 8, z. 2a; 81-86
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nierównomierności rozbioru wody wodociągowej na zmianę jej jakości
Tap water quality variations due to the irregularity of partition
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236344.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
system dystrybucji
jakość wody
wtórne zanieczyszczenie
water supply system
tap water
recontamination
Opis:
Przedstawiono wyniki badań wpływu nierównomierności rozbioru wody w budynku na zmiany jej składu fizyczno-chemicznego w instalacjach wodociągowych. Wykazano, że wzrost poboru wody był przyczyną pogorszenia jakości wody, głównie w zakresie barwy, mętności i zawartości żelaza ogólnego. Wzrost rozbioru wody, a tym samym prędkości przepływu wody, powodował wymywanie zanieczyszczeń z wewnętrznych powierzchni rurociągów. Stwierdzono, że wśród uwalnianych zanieczyszczeń dominowały koloidy i zawiesiny, dlatego poziom zanieczyszczenia wody był proporcjonalny do stężenia żelaza nierozpuszczonego, natomiast nie stwierdzono wpływu nierównomierności rozbioru wody na poziom organicznego zanieczyszczenia wody.
The objective of the study was to analyze the problem of how the irregularity of water partition affects the physicochemical composition of the tap water. It was found that the rise in water consumption accounted for the deterioration of water quality in terms of colour, turbidity, and total iron concentration. The increased partition of the water, as well as the resulting rise in flow velocity, washed away the pollutants from the internal surfaces of the pipes. Among the released pollutants, colloids and suspended solids were found to dominate, and that is why the water pollution level was proportional to the concentration of insol iron. The irregularity of partition had no effect whatsoever on the level of pollution by organic matter.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 4, 4; 21-23
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność filtracji dzbankowej w zmiękczaniu wody wodociągowej i usuwaniu chloru
Performance of jug filtration in tap water softening and chlorine removal
Autorzy:
Kamińska, Gabriela
Puszczało, Ewa
Marszałek, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2163402.pdf
Data publikacji:
2022
Wydawca:
Akademia Techniczno-Humanistyczna w Bielsku-Białej
Tematy:
filtry dzbankowe
woda wodociągowa
twardość wody
chlor
jug filters
tap water
water hardness
chlorine
Opis:
Water hardness, taste, smell, and color are the most important tap water parameters for consumers. Microbiological and physicochemical parameters of tap water should not exceed the permissible values listed in Regulation of Ministry of Health on the quality of water intended for human consumption. Tap water parameters are regularly monitored, however periodically, deviations are allowed, which make it possible to supply water that does not meet the requirements of quality standards. Such a situation causes that consumers have doubts about the health safety of the supplied water. The organoleptic properties of the water such as taste, smell and color can be easily improved at home using jug filters. In this study, we tested the effectiveness of eight inexpensive and easily available jug water filters to soften and remove chlorine from water. Filters were labeled with symbols A, B, C, D, E, F, G, H. Experiments were performed with model water, which was prepared from drinking water taken directly from a sink and spiked with hypochlorite sodium. The hardness of model water was 7.5 mval/L, while free chlorine concentration was equaled 1.1 mg/L. 200 L of model water was filtered by each filter in duplicates. It was found that jug filtration is an effective method for removal of chlorine from water, provided that a use of proper filter. Although, all used filters are dedicated to removal of chlorine from water, not all of them represented a sufficient removal of chlorine. Filters A, B and C were the most effective for chlorine removal. For these filters, chlorine concentration was reduced to the value of 0.075 mg/L. Moreover, for filters A, B, C and E, the concentration of chlorine in the filtrates remained relatively similar throughout the entire experiment. Filters D and H represented the poorest efficiency of chlorine removal. Concentration of chlorine in these filtrates exceeded permissible value recommended by Regulation of Ministry of Health. Among eight studied filters (i.e. 0.3 mg/L), filters A and B are considered as the most effective for water softening. Generally, the efficiency of jug filtration in water softening was at mediocre level and decrease in time. It could have been caused by the high initial hardness of tap water in Gliwice. In the case of very hard water, more often than recommended by the manufacturers replacing the filter cartridges is recommended.
Źródło:
Polish Journal of Materials and Environmental Engineering; 2022, 4(24); 13-20
2720-1252
Pojawia się w:
Polish Journal of Materials and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ spadku zużycia wody w miastach zaopatrywanych z wodociągu grupowego Górnośląskiego Przedsiębiorstwa Wodociągów w Katowicach na jakość wody w systemie dystrybucji
Effect of the Decrease in the Consumption of Water on its Quality in the Water Distribution System of Upper Silesia
Autorzy:
Kuś, K.
Grajper, P.
Ścieranka, P.
Wyczarska-Kokot, J.
Zakrzewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/236376.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system zaopatrzenia w wodę
zużycie wody
jakość wody
water supply system
water consumption
tap water quality
Opis:
Wodociąg grupowy Górnośląskiego Przedsiębiorstwa Wodociągów (GPW) w Katowicach, będący podstawą zaopatrzenia w wodę Górnego Śląska, jest największym tego rodzaju przedsiębiorstwem w Polsce, z którego korzysta około 3 mln mieszkańców. W strukturze materiałowej rurociągów magistralnych o łącznej długości ponad 1100 km w zakresie średnic od 400 mm do 1800 mm, 82% stanowi stal, często bez dodatkowego zabezpieczenia od wewnątrz. Ponad 2-krotny spadek zużycia wody przez ludność i przemysł wpłynął w istotny sposób na pogorszenie parametrów hydraulicznych jej transportu. Dla 33% długości tych rurociągów prędkość przepływu wody nie przekracza 0,1 m/s, a dla 47% zawiera się w przedziale 0,1÷0,5 m/s. Czas przetrzymania wody w systemie dystrybucji, łącznie z przepływem przez zbiorniki wyrównawcze, zawiera się od około 3 godz. do ponad 120 godz. W pracy dokonano analizy porównawczej składu fizyczno-chemicznego i bakteriologicznego wody opuszczającej poszczególne zakłady uzdatniania z jakością wody w zbiornikach sieciowych i charakterystycznych punktach sprzedaży, celu uzyskania odpowiedzi na pytanie jaki wpływ na jakość transportowanej wody ma czas jej przebywania w systemie dystrybucji. Stwierdzono sporadyczne przekroczenia dopuszczalnych wskaźników fizyczno-chemicznych wody w niektórych punktach jej sprzedaży z systemu dotyczące głównie barwy, mętności oraz zawartości związków żelaza i manganu. Wykazano, że większość rurociągów o dużych średnicach pracuje jako osadniki bardzo czułe na chwilowy wzrost natężenia przepływu wody, co może być przyczyną katastrofalnego pogorszenia jakości wody wodociągowej.
The group water supply system Górnośląskie Przedsiębiorstwo Wodociągów (GPW), Katowice, is Poland's largest system of that kind. With water-mains of 1100-km length and diameters varying from 400 to 1800 mm, the GPW serves a population of three million inhabitants. The majority of the pipes are made of steel (82%) without any lining. An over two-fold decrease in water consumption (both by the population and the industry) extended considerably the time of water residence in the distribution system (now ranging between approximately 3 h and over 120 h). Physicochemical and bacteriological analyses were carried out to establish how the residence time affects the quality of transported water. The investigations revealed episodes of exceeded permissible values, mostly those of coloured matter concentration, turbidity, as well as iron compounds and manganese content. The majority of pipes with large diameters were found to act as settling tanks sensitive to a temporary rise in flow rate, posing a serious risk of disastrous water quality deterioration.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 3, 3; 29-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stabilności wody wprowadzanej do sieci wodociągowej
Stability Assessment of Water Introduced into the Water Supply Network
Autorzy:
Wolska, M.
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/236953.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
tap water
chemical stability
biostability
water aggressiveness
nutrients
woda z kranu
stabilność chemiczna
sieć wodociągowa
Opis:
Both chemical and biological stability of water was assessed from the three water supply networks using different water sources: surface, infiltration and the mixed (surface and groundwater). The oxidizing agent content, Langelier and Ryznar corrosivity indexes and water aggressiveness index were chosen as criteria for the water chemical stability assessment. Water biostability was determined on the basis of nutrient content: inorganic nitrogen and phosphate forms as well as biodegradable organic carbon (BDOC). It was established that in respect of chemical stability, the waters had some common characteristics such as dissolved oxygen and chlorine oxidizing agent content, conducive to the electrochemical corrosion process, as well as lack of an aggressive carbon dioxide with the concurrent lack of calcium-carbonate equilibrium supporting scale formation. The Ryznar index values were indicative of the corrosive potential of water; the surface water samples belonged to a clearly ‘corrosive’ range. The biological instability was a constant feature of the tested waters and it was the excessive inorganic nitrogen content that was the most conducive to the bacterial regrowth in the water. In either case, disinfectant content was determined to be inadequate with regard to prevention of biological recontamination of water, which was in contrast with its excess in relation to water corrosivity criterion.
Chemiczna i biologiczna stabilność wody została oceniona w trzech sieciach wodociągowych wykorzystujących różne źródła wody: powierzchniowe, infiltracji i mieszane (powierzchniowych i podziemnych).
Źródło:
Ochrona Środowiska; 2015, 37, 4; 51-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm poszukiwania przyczyn pogorszenia jakości wody w systemach wodociągowych
A comprehensive model for searching the contributors to water quality deterioration in water supply systems
Autorzy:
Denczew, S.
Powiązania:
https://bibliotekanauki.pl/articles/236412.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
pogorszenie jakości
system zaopatrzenia w wodę
tap water
water quality
water deterioration
water supply system
Opis:
Proponowany algorytm poszukiwania przyczyn pogorszenia jakości wody w systemach wodociągowych składa się z dwóch współdziałających i uzupełniających się ciągów, tj. ciągu badań i analiz oraz ciągu działań eksploatacyjnych. Brak kompleksowych opracowań teoretyczno-praktycznych, obejmujących wszystkie podsystemy i niektóre wybrane elementy podatne na zanieczyszczenie wody, podkreśla ważność problemu, jakim jest pogarszanie się jakości wody w systemach wodociągowych. Zaprezentowany model ma wymiar społeczny i ekonomiczny. Zbudowanie konstrukcji obejmującej zbiór czynności uporządkowanych w dwóch ciągach umożliwia skrócenie czasu poszukiwania przyczyn pogorszenia się jakości wody i szybkie przywrócenie stanu normalnej pracy systemu zaopatrzenia w wodę, czyli dostawę wody zgodnie z wymogami w tym zakresie. Wdrożenie proponowanego modelu do praktyki eksploatacyjnej przedsiębiorstw wodociągowych powinno zapewnić z jednej strony sprawne podejmowanie usystematyzowanych czynności w celu ustalenia przyczyn i ich usunięcia, a z drugiej strony zapewnia przekazywanie na bieżąco rzetelnej informacji dla odbiorców.
The proposed model consists of two complementary sequences cooperating with each other - a sequence of research and analysis and a sequence of operational actions. So far, no comprehensive theoretical or practical projects have been developed to comprise all subsystems and some of the elements that are susceptible to water pollution. This lack makes us aware of how important the problem of water quality deterioration in water supply systems is. The model described in this paper is also meaningful in economic and social terms. Building up a structure incorporating a set of actions that have been ordered in two sequences enables us not only to shorten the time which is needed to find the contributors to water quality deterioration, but also to quickly recondition the water supply system, i.e. to restore water delivery in compliance with relevant requirements. The implementation of the proposed model offers two major benefits - taking efficacious, systematized actions to find and remove the deteriorating factors, and transmission of reliable up-to-date information to the users.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 2, 2; 27-30
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stężenie składników nawozowych w wodzie do nawodnień i do picia w Falentach
Nutrient concentration in irrigation water and tap water in Falenty
Autorzy:
Sapek, A.
Nawalany, P.
Barszczewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/338412.pdf
Data publikacji:
2003
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
woda do picia
woda do nawodnień
azotany
fosforany
chlorki
tap water
irrigation water
nitrate
phosphate
chloride
Opis:
W latach 1991–2001 prowadzono systematyczne badania stężenia składników nawozowych w wodzie do nawodnień i do picia z ujęć w Falentach. Wodę do nawodnień ujmowano z Cieku Wschodniego spod Laszczek, którego część wody pochodzi z objętych ochroną źródlisk, a w dolnym biegu jest pod wpływem intensywnych upraw ogrodniczych oraz osiedli wiejskich. W latach objętych badaniami obserwowano około dwukrotne zwiększenie stężenia azotu azotanowego i fosforanów w tym cieku, co świadczy o jego postępującej eutrofizacji. Natomiast stężenie azotu amonowego zmniejszyło się w tym czasie. Nie obserwowano żadnego trendu zmian stężenia pozostałych oznaczanych składnikach – chlorków, sodu, potasu, magnezu i wapnia. W Zakładzie Chemii Gleby i Wody IMUZ próbkami odniesienia jest woda bieżąca z kranu z ujęcia wody do picia na głębokościach 20 i 36 m w Falentach. W czasie siedmiu lat wykonywania analiz stwierdzono, że stężenie azotu azotanowego w tej wodzie zmniejszyło się, zaś stężenie azotu amonowego, fosforanów i chlorków pozostawało bez większych zmian.
Concentration of nutrients in water used for irrigation purposes and in tap water from deep sources in Falenty was analysed during 1991–2001. The irrigation water originated from a steam flowing out from springs situated on areas protected as natural reserve 2 km upstream the sampling site. There are arable fields cropped with vegetable and a settlement along the lower course of the stream. Concentrations of nitrate nitrogen and phosphate significantly increased during the study period, which proves advancing eutrophication of the stream. Concentration of ammonium nitrogen decreased in the same time. No changes in the concentration of other investigated nutrients were observed. Tap water is used in the laboratory of Department of Soil and Water Chemistry as a reference sample. Concentration of nitrate nitro gen decreased and concentrations of ammonium nitrogen, phosphate and chloride did not change markedly during 7 years of analyses.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2003, T. 3, z. spec. (6); 79-84
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość bakteriologiczna wody wodociągowej
Bacteriological quality of tap water
Autorzy:
Zamorska, J.
Zdeb, M.
Papciak, D.
Powiązania:
https://bibliotekanauki.pl/articles/949970.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
bakteriologia wody
woda do picia
woda wodociągowa
cytometria przepływowa
water bacteriology
drinking water
tap water
flow cytometry
Opis:
Najbardziej czułą metodą wykrywania skażenia wody wodociągowej jest badanie mikrobiologiczne. Bezpieczeństwo wód pod względem mikrobiologicznym jest oceniane głównie na podstawie wyników tradycyjnych badań hodowlanych, umożliwiających wzrost kolonii bakterii na podłożach odżywczych. W ostatnich latach zastosowanie w mikrobiologii znalazła nowoczesna technika cytometrii przepływowej. Diagnostyczna metoda oparta na cytometrii przepływu jest znacznie szybsza, a także bardziej wszechstronna. Badania jakości mikrobiologicznej wody wodociagowej prowadzono w rejonach powiatu rzeszowskiego, tj. w rejonie systemu wodociągowego zasilanego z ujęcia wód powierzchniowych oraz w rejonie małych systemów wodociągowych zasilanych z ujęć wód podziemnych. Zakres analizy mikrobiologicznej jakości wody wodociągowej opierał się na oznaczeniu wybranych wskaźników stanu sanitarnego wody tj; ogólnej liczby bakterii psychrofilnych i mezofilnych na agarze odżywczym (referencyjnym) zwanym Agarem A oraz dodatkowo na agarze wzbogaconym zwanym Agarem R, liczby bakterii grupy coli oraz paciorkowców kałowych. Oznaczenie ogólnej liczby mikroorganizmów metodą cytometrii przepływowej wykonywano z zastosowaniem dwóch barwników Sybr Green oraz jodku propidyny. Woda z ujęć wód podziemnych, nie będących pod stała kontrolą mikrobiologiczną posiadała gorsze parametry mikrobiologiczne. Stosowane nowe metody oznaczeń mikrobiologicznych wykazywały większe ilości zanieczyszczeń mikrobiologicznych.
The most sensitive method of detecting contamination in water supply networks is microbiological testing. Microbiological water safety is evaluated mainly based on the results of traditional tests that rely on bacteria culturing on the so called bacterial growth mediums. Flow cytometry is a modern technology that has been used in microbiology only recently. The diagnostic method based on flow cytometry is much faster and more versatile. Microbiological quality testing was conducted in rzeszowski district, in the area of water network supplied by surface waters, and in the area of water network supplied by underground waters. The scope of the analysis of the microbiological quality of tap water was based on the determination of selected indicators of the sanitary condition of water ie; the total number of psychrophilic and mesophilic bacteria on nutrient agar (reference) called Agar A and additionally called agar supplemented with R, the number of coliforms and faecal streptococci. Determination of the total number of microorganisms by flow cytometry was performed using two dyes SYBR Green and iodide pyridine. Water from underground water intakes, not under the permanent control of microbial had worse microbiological parameters. Used new methods of microbiological assays showed greater amounts of microbiological contamination.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 219-225
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza błędów generowanych w procesie preparatywnym na przykładzie analizy wybranych pierwiastków w próbkach wody techniką ASA
Analysis of errors generated in the preparative process with the example of analysis of selected elements in the water samples, using ASA technique
Autorzy:
Szmidt, E.
Powiązania:
https://bibliotekanauki.pl/articles/107672.pdf
Data publikacji:
2015
Wydawca:
Instytut Transportu Samochodowego
Tematy:
woda wodociągowa
woda destylowana
mineralizacja
zatężanie
spektrometria atomowa
tap water
distilled water
mineralization
concentration
absorption spectrometry
Opis:
Zaprezentowano wyniki analizy próbek wody wodociągowej i destylowanej. Pobrane losowo próbki poddano mineralizacji lub/i zatężaniu oraz zanalizowano następujące pierwiastki: Cu, Pb, Cr, Cd, Ag techniką absorpcyjnej spektrometrii atomowej. Następnie przeprowadzono dyskusję wpływu etapów preparatyki oraz warunków środowiskowych na otrzymane wyniki oraz sformułowano wnioski.
The results of analysis of tap and distilled water samples have been presented. Randomly selected samples have been subjected to mineralization and / or concentration, and the following elements have been analyzed: Cu, Pb, Cr, Cd, Ag using atomic absorption spectrometry technique. Then, a discussion was held on the impact of preparation stages and environmental conditions on the results obtained and conclusions have been drawn.
Źródło:
Transport Samochodowy; 2015, 3; 81-96
1731-2795
Pojawia się w:
Transport Samochodowy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie programów symulujących skład jonowy wody do oceny stabilności chemicznej wody wodociągowej
Assessing the chemical stability of tap water by means of the software for ionic composition simulation
Autorzy:
Łomotowski, J.
Siwoń, Z.
Powiązania:
https://bibliotekanauki.pl/articles/236350.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
osady w sieci
skład jonowy
stabilność wody
tap water
precipitation
ionic composition
water stability
Opis:
Wymywanie osadów z sieci wodociągowej może występować na skutek zmian warunków hydraulicznych oraz składu chemicznego wody w sieci wodociągowej. Może być także efektem zmian w układzie technologicznym stacji uzdatniania wody, zmian składu wody surowej (szczególnie na ujęciach wód powierzchniowych) lub mieszania się w sieci wodociągowej wód pochodzących z różnych ujęć. Zastosowanie programów komputerowych do symulacji składu jonowego wody i obliczania indeksów stabilności w tych wypadkach może okazać się cennym narzędziem diagnostycznym. W pracy przedstawiono możliwości wykorzystania programu PHREEQC 2.3 do symulacji składu jonowego wody w praktyce wodociągowej. Stwierdzono ich użyteczność przy prognozowaniu zdolności do wytrącania minerałów z wody wodociągowej oraz sprawdzania poprawności analiz chemicznych wody. Wykazano, że na podstawie indeksów stabilności chemicznej wody można diagnozować procesy zachodzące w sieciach wodociągowych.
Mineral precipitation in the water-pipe network occurs due to the change in the hydraulic conditions or in the chemical composition of the water. But there are some other contributing factors, e.g. the change in the treatment train applied, variations in the composition of raw water (especially at surface water intakes), or the water mix produced in the pipeline by the inflow from a variety of intakes. It seemed therefore advisable to evaluate the chemical stability indexes for the pipe water with the help of the software for simulating the ionic composition of the water, as this was likely to be a useful diagnostic tool. For the purpose of the study reported on in this paper, use was made of the software PHREEQC for ionic composition simulation in water distribution engineering. The software was found to be of utility in predicting mineral precipitation from the tap water and in assessing the reliability of chemical analyses. The study has shown that with the chemical stability indexes obtained via the described method it is possible to predict the processes occurring in the water distribution networks.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 4, 4; 13-16
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobra woda prosto z kranu w Krakowie
In Kraków, good water straight from the tap
Autorzy:
Biedrzycka, A.
Powiązania:
https://bibliotekanauki.pl/articles/364506.pdf
Data publikacji:
2013
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
woda
kampania
Wodociągi Krakowskie
reklama
woda kranowa
spożycie
water
campaign
Waterworks Krakow
advertising
tap water
consumption
Opis:
Wodociągi Krakowskie rozpoczęły kampanię zachęcającą do picia wody kranowej. Kampania, przebiegająca pod hasłem „Dobra woda prosto z kranu”, ma rozpowszechnić, potwierdzić i utrwalić przekonanie, że woda z kranu jest zdatna do bezpośredniego spożycia. Akcja jest adresowana do krakowian, mieszkańców sąsiednich gmin pracujących lub uczących się w Krakowie, a także turystów.
Wodociągi Krakowskie (Waterworks Kraków) have launched a campaign to promote drinking tap water. The campaign, with the catchphrase “Good water straight from the tap”, aims to promote and popularize drinking water straight from the tap. The campaign is targeted at citizens of Kraków, citizens of other communes, who work or study in Kraków, and tourists.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2013, 3; 30-31
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health risk assessment resulting from the presence of Legionella bacteria in domestic hot water in public buildings – the results of a pilot study
Autorzy:
Kmiecik, Ewa
Wątor, Katarzyna
Chochorek, Aneta
Kołodziej, Mateusz
Mika, Anna
Krawiec, Arkadiusz
Herzig, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1841764.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Legionella pneumophila
tap water
public building
quantitative risk assessment
microbial risk assessment
risk matrix
Opis:
The aim of the study was to assess the risk posed by Legionella bacteria in a public building in Krakow. An old building with internal installation risers of different ages, as well as draw-off points of different types, was selected for testing. Samples were collected during two campaigns. In one sample of the first series of tests, no bacteria were found. During the second series of tests, no Legionella bacilli were found in just one sample and in one sample only 4 colony-forming units were detected. At the remaining draw-off points (water taps), the bacteria count detected were greater than the maximum threshold allowed by legal regulations (admissible threshold for public utility buildings – 100 cfu/100 mL). No morphological differences were observed with respect to the occurrence of specific serogroups. In 14 samples, Legionella pneumophila serogroups 2–14 were found, while the Legionella pneumophila serogroup 1 was only found in one sample. The risk assessment was also carried out based on a semi-quantitative risk matrix approach and as a quantitative microbial risk assessment. The risk matrix approach was successfully implemented for the recognition of the potential risk associated with the Legionella occurrence in a water system. The calculated annual cumulative risk is high. The research shows that even if the weekly inhalation exposure dose (and therefore the calculated risk) is high, the number of Legionella pneumophila illness cases found can be equal to zero. This is probably due to the large uncertainty associated with QMRA determination. The size of the room in which the contaminated water is used also affects the possibility of infection.
Źródło:
Geology, Geophysics and Environment; 2021, 47, 1; 41-52
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu promieniowania nadfioletowego na stabilność mikrobiologiczną wody
Studies of the influence of UV irradiation on drinking water microbial stability
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Powiązania:
https://bibliotekanauki.pl/articles/237624.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
oczyszczanie wody
dezynfekcja
związki organiczne
stabilność wody
tap water
water treatment
disinfection
organic matter
water stability
Opis:
Wykorzystanie promieniowania UV do dezynfekcji wody staje się coraz powszechniejsze w polskiej praktyce oczyszczania wody przeznaczonej do spożycia przez ludzi. Dezynfekcja wody promieniami UV często jest łączona sekwencyjnie z dezynfekcją chemiczną, aby zapobiec wtórnemu rozwojowi bakterii w systemach dystrybucji wody. Znane są jednak przypadki, że woda po procesie dezynfekcji promieniami UV podawana jest wprost do sieci wodociągowej, bez dodatkowej chemicznej ochrony. Artykuł przedstawia wyniki badań nad wpływem promieniowania UV na zmiany stabilności mikrobiologicznej wody w krakowskiej sieci wodociągowej zasilanej ze stacji oczyszczania wody „Raba”. Próbki wody poddano w warunkach laboratoryjnych naświetlaniu promieniami UV za pomocą niskociśnieniowej lampy UV TNN 15/32 w reaktorze fotochemicznym LRS-3 firmy Heraeus. Zastosowano dawki promieniowania UV wynoszące 400 J/m2, 1860 J/m2 oraz 10000 J/m2. Stabilność mikrobiologiczną wody oceniano na podstawie obserwacji wzrostu bakterii heterotroficznych w czasie do 18 d. Analiza otrzymanych wyników pokazała, że promieniowanie UV może niekorzystnie wpływać na stabilność mikrobiologiczną wody w systemie dystrybucji. Wykazano, że w próbce wody naświetlanej promieniami UV dawką 400 J/m2 liczba bakterii heterotroficznych była ponad 3-krotnie większa niż w próbce wody poddanej tylko ozonowaniu. Stwierdzono, że większe dawki promieniowania UV oraz sekwencyjne stosowanie ozonowania i promieniowania UV, najprawdopodobniej ze względu na mineralizację związków organicznych, poprawiały stabilność mikrobiologiczną wody.
Application of UV radiation for water disinfection becomes more and more popular in Polish treatment plants that supply drinking water. UV disinfection is often sequentially coupled with chemical disinfection to prevent secondary growth of bacteria in water distribution systems. However, there are cases where directly after the UV disinfection water is pumped into a distribution system, without any additional chemical protection. The article presents results of the research on the influence of UV radiation on variations in water microbial stability in the distribution system supplied by Raba water treatment plant. Water samples were irradiated in laboratory conditions in the photochemical reactor (Heraeus) with the UV low-pressure lamp TNN 15/32. The UV doses of 400 J/m2, 1860 J/m2 and 10,000 J/m2 were applied. Water microbial stability was determined on the basis of heterotrophic bacteria growth rate in the period of up to 18 days. An analysis of the results demonstrated that UV radiation could adversely affect water microbial stability in distribution systems. The highest number of heterotrophic bacteria, over three-times higher compared to a purely ozonated sample, was recorded in the water sample irradiated with 400 J/m2. Higher doses of UV radiation as well as ozone/UV sequence improved water microbial stability, most likely due to organic matter mineralization.
Źródło:
Ochrona Środowiska; 2015, 37, 4; 47-50
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania stabilności biologicznej wody w wybranych systemach wodociągowych
Biological stability of drinking water in selected water distribution systems
Autorzy:
Sokołowska, A.
Jankowska, K.
Kulbat, E.
Olańczuk-Neyman, K.
Powiązania:
https://bibliotekanauki.pl/articles/237884.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda powierzchniowa
woda podziemna
woda wodociągowa
ogólna liczba bakterii
surface water
groundwater
tap water
total bacteria number
Opis:
W pracy przedstawiono wyniki badań bakteriologicznych wody powierzchniowej i wód podziemnych (ujmowanych, oczyszczonych i rozprowadzanych siecią wodociągowa w rejonie Trójmiasta), które zasilają system dystrybucji charakteryzujący się małą wartością stosunku powierzchni kontaktu do objętości przesyłanej wody (≈0,65), a także wyniki laboratoryjnych badań ich stabilności biologicznej. Dokonano również oceny skuteczności stosowanych procesów technologicznych w zmniejszaniu ogólnej liczby bakterii, a w badaniach laboratoryjnych określono podatność wody wprowadzanej do systemu dystrybucji na ich wtórny wzrost. Stwierdzono, że w konwencjonalnym systemie oczyszczania wody powierzchniowej miała miejsce wysoka (95%) eliminacja ogólnej liczby bakterii, a proste systemy oczyszczania wód podziemnych były mało skuteczne w ich eliminacji. Wykazano, że możliwy jest wzrost ogólnej liczby bakterii w wodzie (nawet o 20%) na skutek wypłukiwania bakterii z filtrów. W systemach wodociągowych zasilanych zarówno wodą powierzchniową, jak i wodami podziemnymi stwierdzono wzrost wartości ogólnej liczby bakterii, przy czym był on większy w przypadku sieci zasilanej wodą powierzchniową (na odcinku 6 km – 330%) niż w niedezynfekowanej wodzie podziemnej (na 8 km odcinku – 170%). W badaniach laboratoryjnych potwierdzono korzystny wpływ procesów oczyszczania wody na zmniejszenie jej podatności na wtórny wzrost bakterii. W oczyszczonej wodzie podziemnej inkubowanej przez 7 d w temperaturze 5÷10oC szybkość wzrostu ogólnej liczby bakterii była o 80% mniejsza niż w ujmowanej wodzie.
Results of microbiological analysis and biological stability of surface and groundwater (taken, treated and distributed in the Tri-city region) which supply a distribution system with low contact surface to transferred water volume ratio (≈0.65) were presented. Additionally, the effectiveness of technological processes in reduction of the total number of bacteria (TNB) was evaluated and laboratory tests determined the susceptibility of water introduced into the system to the bacterial regrowth. It was established that high elimination (95%) of TNB occurred in the conventional surface water treatment system, while simple groundwater treatment systems were not effective in eliminating these bacteria. TNB was demonstrated to increase (even up to 20%) as a result of periodic leaching of bacteria from filters. In both surface and groundwater supply systems an increase in the TNB was observed. It was higher along the surface water network (330% for a 6-km section) than the non-disinfected groundwater network (170% for a 8-km section). The laboratory studies confirmed the beneficial effect of treatment processes on reduction of water susceptibility to bacterial regrowth. Increase in the total number of bacteria in the treated groundwater after 7-day incubation at temperatures ranging from 5 to 10oC was approximately 80% lower than in the raw water.
Źródło:
Ochrona Środowiska; 2015, 37, 4; 31-37
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemical composition of the commerce mineral waters versus tap water in the city of Kielce
Porównanie składu chemicznego dostępnych w handlu wybranych wód mineralnych ze składem wody wodociągowej miasta Kielce
Autorzy:
Gawdzik, A.
Garbat, K.
Gawdzik, J.
Powiązania:
https://bibliotekanauki.pl/articles/126242.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mineral water
tap water
ion balance
SI index
woda mineralna
woda wodociągowa
bilans jonowy
indeks stabilności SI
Opis:
Comparative analysis of the chemical composition of the commerce mineral and spring waters to tap water in the district city of Kielce has been presented in this paper. The research has been done using the latest analytical equipment which was stocked with ion chromatograph 883 Basic IC plus and spectrometer Optima 8000. The PHREEQC 2.17 program has been used in order to calculate the ion balances and SI index.
W pracy porównano skład chemiczny dostępnych w handlu wybranych wód mineralnych z wodą wodociągową miasta Kielce. Badaniami objęto wody mineralne niskomineralizowane: Kroplę Beskidu, Żywiec Zdrój i Dobrowiankę; średniomineralizowane: Nałęczowiankę, Nestle Aquarel i Cisowiankę oraz wysokomineralizowane: Staropolankę 2000, Muszyniankę i Piwniczankę. Oznaczenia wykonano, posługując się najnowocześniejszym sprzętem analitycznym, tj. chromatografem jonowym 883 Basic IC plus firmy Metrohm oraz spektrometrem emisyjnym ze wzbudzeniem, w indukowanej plaźmie, Optima 8000 firmy Perkin Elmer. Bilanse jonowe oraz wartość indeksów stabilności uzyskano, wykorzystując programy Exel oraz PHREEQC 2.17.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 41-46
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of metal concentrations in tap-water – from source to the tap: a case study from Szczecin, Poland
Autorzy:
Górski, J.
Siepak, M.
Powiązania:
https://bibliotekanauki.pl/articles/94287.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
chemical quality
water distribution network
metals
tap water
jakość chemiczna
sieć dystrybucji wody
metale
woda z kranu
Opis:
The concentrations of Al, As, Cd, Cu, Pb, Zn, Ni, Fe and Mn were determined in June 2010 for 100 tap-water samples, collected directly at consumers in the older part of the city of Szczecin (Poland). Increased concentrations of metals were thus detected. This concerns mainly Fe (19% of samples showed concentrations above drinking-water quality standards) and Pb (5%). In some samples, the maximum admissible concentration levels for Mn, Cu and Ni were also exceeded. This was not the case for Al, despite the use of aluminium compounds during water treatment; the Al concentrations in treated water were, however, significantly higher than in raw water. It was also found that (1) the corrosive properties of water (low alkalinity and increased concentration of sulphates), (2) the water-treatment processes causing a decrease of the pH and an increase of the CO2, and (3) transport of the treated water over long distances (30 km) provide favourable conditions for the leaching of metals from water-pipe networks. The type of material used in domestic plumbing and the content of Ce, Fe, Mn, Ni and Cd in the tap-water at consumers show a correlation. The high content of Pb is mainly a result of lead pipes connecting the network to the buildings.
Źródło:
Geologos; 2014, 20, 1; 25-33
1426-8981
2080-6574
Pojawia się w:
Geologos
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wtórnego zanieczyszczenia niestabilnej chemicznie wody w systemie dystrybucji
Recontamination of Chemically Unstable Water in the Distribution System
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237225.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
korozyjność wody
stabilność chemiczna
system dystrybucji
produkty korozji
water corrosivity
chemical stability
distribution system
tap water
corrosion products
Opis:
Brak stabilności chemicznej wody wprowadzanej do systemu dystrybucji jest przyczyną pogarszania jej jakości, w większości próbek wody nawet do poziomu ponadnormatywnego. W badaniach wykazano, że największe zmiany składu fizyczno-chemicznego wody dotyczyły zawartości żelaza ogólnego i nierozpuszczonego, a także barwy i mętności wody. Dodatkowo, wraz ze wzrostem odległości punktu poboru wody od zakładu oczyszczania wody, wzrastało zużycie chloru wolnego, co stwarzało warunki do rozwoju mikroorganizmów. Stwierdzono, że procesy zachodzące podczas transportu wody w sieci wodociągowej powodowały intensyfikację agresywności korozyjnej wody, co sprzyjało rozpuszczaniu osadów zgromadzonych w rurociągach, będących źródłem zanieczyszczenia wody głównie produktami korozji żeliwnych i stalowych przewodów wodociągowych.
Chemical instability is the main contributor to the deterioration of water quality during transport in the distribution system. In the investigated water distribution system, the most noticeable changes in the water quality parameters were those in total and insoluble iron concentrations, colored matter content and turbidity. The persistence of low disinfectant concentrations promoted bacterial regrowth and water contamination due to the metabolism of bacterial by-products. The processes that occured in the distribution system during water transport enhanced the corrosivity of the water, which favored the dissolution of pipe encrustation. The dominating pollutants were found to be products of cast iron and steel pipe corrosion.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 4, 4; 34-38
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe przepisy niemieckie dotyczące jakości wody przeznaczonej do spożycia - niektóre wymagania
Major Requirements in the Novel German Water Act Based on the EU Directive 98/83
Autorzy:
Rybicki, S. A.
Powiązania:
https://bibliotekanauki.pl/articles/236362.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dyrektywa Unii Europejskiej
niemieckie przepisy o jakości wody
jakość wody pitnej
EU directive
German Water Act
tap water quality
Opis:
Przedstawiono wybrane informacje dotyczące rozporządzenia w sprawie jakości wody do picia (TrinkwV-2001), które obowiązuje w RFN od 1 stycznia 2003 r. Zostało ono oparte na dyrektywie Unii Europejskiej 98/83. Zakres rozporządzenia obejmuje - obok spraw podstawowych, tj. określenia wymagań w sprawie jakości wody, także inne zagadnienia. Są to m.in. zalecenia organizacyjne, zasady współpracy z wydziałami zdrowia, sprawy odpowiedzialności za przestrzeganie tych przepisów itp. Podano także syntetycznie zasadnicze różnice wymagań zawartych w rozporządzeniach niemieckich z lat 1990 i 2001, a także rozporządzeniach polskich wydanych w latach 1990 i 2002. Na wdrożenie rozporządzenia TrinkwV-2001 przewidziano 1,5 roku. Przedstawiono także uwagi specjalistów niemieckich z różnych instytucji, dotyczące niejednoznacznych szczegółów omawianego rozporządzenia. Omówiono także zagadnienia, które uznano za ważne także dla personelu polskich przedsiębiorstw wodociągowych.
The Water Act of interest, TrinkwV-2001, has been in force in Germany since January 1, 2003. Besides the fundamental demands made on water quality, the Act specifies many other related problems such as appropriate organization and management, collaboration with Health Departments, responsibility for the observance of relevant regulations, etc. The author of the present paper points to the basis differences in the requirements between the German Enactment of 1990 and that of 2001, as well as between the Polish Enactments of 1990 and 2002. The implementation of the TrinkwV-2001 Act will take 18 months. The author of the paper also presents the commentaries made by German specialists from different institutions on some equivocal details which are found in the TrinkwV-2001 Act. Moreover, the paper emphasizes a number of problems which are of importance to the staff of the waterworks in Poland.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 3, 3; 9-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości i opłacalność wykorzystania ścieków szarych do nawadniania roślin
Feasibility and economic efficiency of greywater reuse for plant irrigation
Autorzy:
Nguyen, T. H.
Błażejewski, R.
Spychała, M.
Powiązania:
https://bibliotekanauki.pl/articles/401811.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wykorzystanie ścieków
nawadnianie
woda wodociągowa
ścieki szare
życica trwała
greywater reuse
irrigation
tap water
greywater
perennial ryegrass
Opis:
Celem badań była ocena wpływu użycia ścieków szarych (surowych i oczyszczonych) do nawadniania trawy (życica trwała, Lolium perenne), wyhodowanej na drobnym piasku, na przyrost biomasy w okresie 4 miesięcy. Zastosowano trzy rodzaje cieczy do nawadniania (woda wodociągowa, surowe ścieki szare i oczyszczone ścieki szare) w na dwóch poziomach dawek częściowych: niskim i wysokim (5 i 15 mm na tydzień), w dawkach całkowitych o wysokości 15, 25, 35 i 45 mm na tydzień. Ścieki surowe z pralki, kąpieli w wannie i mycia rąk charakteryzowały się następującymi wskaźnikami: ChZT - 247 ± 33 mg O2·dm-3, BZT5 - 81 ± 12 mg O2·dm-3, azot całkowity - 7,2 ± 0,9 mg N·dm-3 i fosfor całkowity - 4,7 ± 0,7 mg P·dm-3, zaś ścieki oczyszczone odpowiednio: 81 ± 12 mg O2·dm-3, 23 ± 6 mg O2·dm-3, 4,8 ± 0.9 mg N·dm-3, 2 ± 0,2 mg P·dm-3. Wyniki badań wykazały, że wzrost nadziemnej biomasy jest zależny od całkowitej dawki cieczy w zakresie 15 do 45 mm na tydzień. Średni przyrost biomasy trawy podlewanej wodą wodociągową, ściekami oczyszczonymi i ściekami surowymi dla dawki częściowej 5 mm na tydzień (w ramach dawek całkowitych 15-45 mm na tydzień) wyniósł 40,5 ± 7,5, 39,1 ± 7,3, 42,8 ± 6,0 mg s.m., odpowiednio, a dla dawki częściowej 15 mm na tydzień: 52,6 ± 7,8, 54,0 ± 7,5, 50,3 ± 9,2 mg s.m., odpowiednio. Różnica przyrostu suchej biomasy nawadnianej oczyszczonymi ściekami szarymi dawką częściową 5 mm na tydzień i dawką częściową 15 mm na tydzień (na korzyść tej wyższej) była większa niż dla pozostałych rodzajów cieczy; była też istotna statystycznie (p > 6%). Badania wykazały, że surowe i oczyszczone ścieki szare, mogą stanowić alternatywę dla wody wodociągowej w kontekście nawadniania trawnika, nie wywierając negatywnego wpływu na przyrost biomasy.
The study was conducted on grass (Lolium perenne) grown on fine sand in pots to evaluate the effect of greywater reuse on total dry biomass of grass during 4 months. The experiment has been designed as full factorial with total water load: 15, 25, 35 and 45 mm·week-1. Three categories of irrigation water (tap water, treated greywater, raw greywater) were tested in conditional combination with two levels for each category that is the low and high level at 5 and 15 mm·week-1, respectively. The COD, BOD5, total nitrogen, total phosphorus is 247 ± 33 mg·dm-3, 81 ± 12 mg·dm-3, 7.2 ± 0.9 mg·dm-3, 4.7 ± 0.7 mg·dm-3 of raw greywater and 81 ± 12 mg·dm-3, 23 ± 6 mg·dm-3, 4.8 ± 0.9 mg·dm-3, 2 ± 0.2 mg·dm-3 of treated greywater, respectively. The results showed that the dry biomass yields increase when increasing total irrigation water dose from 15 to 45 mm·week-1. The dry biomass yields at 5 mm·week-1 share of tap water, treated greywater, or raw greywater in total irrigation water doses 15-45 mm·week-1 were equal to 40,5 ± 7,5, 39,1 ± 7,3, 42,8 ± 6,0 mg d.m. and at 15 mm·week-1 partial dose: 52,6 ± 7,8, 54,0 ± 7,5, 50,3 ± 9,2 mg d.m. per pot, respectively. The increase in dry biomass yield of grass irrigated with treated greywater (partial dose from 5 to 15 mm·week-1) was higher and more significant (p = 0.13, 0.06, 0.37) than in the two other cases. The study concludes that treated greywater, raw greywater can be a partial or complete replacement for tap water without compromising ryegrass biomass yield.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 6; 80-86
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zmian jakości wody w przewodach wodociągowych z wykładziną cementową
Water quality variations in cement-lined water-pipe networks
Autorzy:
Wąsowski, J.
Kowalski, D.
Kowalska, B.
Kwietniewski, M.
Zawilska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236692.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
sieć wodociągowa
wykładzina cementowa
stabilność chemiczna
zanieczyszczenie wody
tap water
water-pipe network
cement lining
chemical stability
water contamination
Opis:
Badania przeprowadzone w instalacji modelowej zasilanej wodą podziemną wykazały, że woda kontaktująca się z wykładziną cementową stopniowo traciła właściwości agresywne i nabierała zdolności do wytrącania węglanu wapnia. Świadczyło to o przechodzeniu składników cementu z wykładziny do wody wodociągowej. Poza głównymi składnikami (wapń, magnez, glin) stwierdzono obecność w wodzie także pierwiastków śladowych (cynk, bar, chrom, ołów, nikiel, kobalt), przy czym nie były to ilości znaczące. Wykazano, że wymywanie pierwiastków z cementu przebiegało intensywniej do wody poddawanej chlorowaniu. Końcowa zawartość wszystkich oznaczonych pierwiastków w wodzie po kontakcie z wykładziną cementową była znacznie poniżej wartości dopuszczalnych w wodzie przeznaczonej do spożycia.
Experiments performed in a model pipe system fed with underground water demonstrated that tap water exposed to cement-lining gradually lost its corrosive properties and continued to develop its potential for calcium carbonate precipitation. This was an indication that cement components were released from the lining into the water residing in the pipes. Apart from its main components (calcium, magnesium and aluminum), the water contained small quantities of trace elements (zinc, barium, chromium, lead, nickel and cobalt). The study produced the following findings: leaching of elements from the cement lining was enhanced upon exposure to chlorinated water, and the final concentration values of all the elements detected in the water after contact with the cement lining were much lower than those permissible for drinking water.
Źródło:
Ochrona Środowiska; 2012, 34, 1; 53-58
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarządzanie jakością wody w systemie wodociągowym
Water quality management in a water distribution system
Autorzy:
Kowalski, D.
Powiązania:
https://bibliotekanauki.pl/articles/236720.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
jakość wody
zarządzanie jakością
sieć wodociągowa
korygowanie jakości wody
water quality
quality management
tap water
water-pipe network
corrective actions
Opis:
Przedsiębiorstwo wodociągowe może być traktowane jako zakład produkcyjny, którego głównym umownym produktem jest woda, zaś podstawowym elementem produkcji jest dostarczanie wody o odpowiedniej jakości do odbiorców. Ujmowanie, oczyszczanie i dostarczanie wody poddawane są procesom planowania, kontroli, analizy oraz działaniom korygującym. Działania korygujące w przypadku przedsiębiorstw wodociągowych realizowane są głównie na wejściu do sieci wodociągowej, natomiast korygowanie jakości wody w samej sieci sprowadza się głównie do płukania i czyszczenia przewodów. W efekcie, w przypadku niedotrzymania wskaźników jakościowych i konieczności płukania przewodów, tracona jest znaczna część wody wodociągowej znajdującej się w systemie. W pracy zaproponowano dwie metody korygowania jakości wody w sieci wodociągowej, przy jednoczesnym ograniczeniu jej strat. Pierwsza wykorzystuje zbiorniki sieciowe, natomiast druga sieciowe stacje doczyszczania wody. Przydatność tych metod w procesie zarządzania jakością wody przetestowano za pomocą obliczeń symulacyjnych na przykładzie dwóch wybranych miast w Polsce. Wyniki symulacji sugerują, że zastosowanie obu metod może prowadzić zarówno do korekty jakości wody w sieci, jak również przyczynić się do ograniczenia skutków przewymiarowania systemów wodociągowych.
In this paper a water company is considered to be a production plant, where water is the main product, and the problem of supplying the user with water of the quality desired constitutes an important part of the production process. The processes of water intake, treatment and supply are made subject to planning, control, analysis and corrective actions. In most instances, corrective actions are taken at the input of the water-pipe network. Water quality correction in the water-pipe network generally includes pipe cleansing and flushing. In consequence, when the water fails to meet the required quality parameters, or when there is a need to flush the pipes, a major part of the water volume stored in the pipeline will be lost. In the paper two methods have been proposed for correcting water quality in the water distribution system, which enable the potential water loss to be reduced. One of these makes use of the storage tanks; the other one uses the network's cleansing and flushing stations. The applicability of the methods to the process of water quality management was tested by computer simulations, choosing two municipal water distribution systems as cases in point. The results suggest that the two methods will not only enable a correction of water quality in the distribution network, but also help reduce the implications of overdesign.
Źródło:
Ochrona Środowiska; 2009, 31, 3; 37-40
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie chromatografii jonowej do oceny jakości wód wodociągowych ujmowanych w wybranych punktach województw opolskiego i śląskiego
Application of ion chromatography to evaluate top water quality included in the selected points of Opole and Silesian regions
Autorzy:
Szewczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/391925.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
woda wodociągowa
jakość
ocena jakości
chromatografia jonowa
detekcja konduktometryczna
tap water
quality
quality assessment
ion chromatography
conductometric detection
Opis:
Celem pracy jest zbadanie zawartości jonów w wodach pochodzących z sieci wodociągowych województw opolskiego oraz śląskiego. Stężenia szeregu wybranych anionów i kationów oznaczono przy wykorzystaniu chromatografu jonowego z detekcją konduktometryczną. Według rozporządzeń Ministra Zdrowia z 2010 r. oraz Ministra Środowiska z 2004 i 2008 r. obecność wybranych jonów w wodzie do spożycia musi mieścić się w wyznaczonych granicach. Najbardziej szkodliwe jony to anion azotanowy (III) oraz kation amonowy. Wysokie stężenia tych jonów w wodzie są bardzo niebezpieczne dla człowieka i mogą powodować poważne problemy zdrowotne. Zawartość składników jonowych w poszczególnych próbkach jest rozbieżna, na co wpływ mają różne czynniki (zaludnienie, urbanizacja, położenie geograficzne, utwory geologiczne czy technika uzdatniania). Należy prowadzić ciągły monitoring wód przeznaczonych do spożycia, by utrzymać ich jakość na odpowiednim poziomie.
Aim of this paper is to investigate the ion content in top water from region of Opole and of Upper Silesia. The concentrations of a number of selected cations and anions were determined using ion chromatography with conductivity detection. According to the Regulations, the Minister of Health from 2010 and Minister of the Environment from 2004 and 2008, the presence of selected ions in drinking water must be within the designated ridges. The most harmful ions are nitrate anion (III) and ammonium cation. High concentrations of these ions in water are very dangerous for humans and can cause serious health problems. The content of ionic components in each sample is divergent, which is influenced by various factors (population, urbanization, geographical location, geological formations or treatment technique). There should be a continuous monitoring of water intended for human consumption in order to maintain their quality at the appropriate level.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2013, R. 6, nr 13, 13; 68-79
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania modelowe rozprzestrzeniania się butylohydroksytoluenu (BHT) migrującego z rur polietylenowych (PE-HD) do wody
Model investigations into the propagation of butylated hydroxytoluene (BHT) migrating from high density polyethylene pipes (HDPE) to water
Autorzy:
Widomski, M.
Kowalska, B.
Kowalski, D.
Powiązania:
https://bibliotekanauki.pl/articles/236927.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
przeciwutleniacz
butylohydroksytoluen
modelowanie numeryczne
dynamika płynów
tap water
antioxidant
butylated hydroxytoluene
numerical modeling
computational fluid dynamics (CFD)
Opis:
Rury wykonane z polietylenu wysokiej gęstości (PE-HD) są szeroko stosowane do budowy sieci i instalacji wodociągowych. Migracja stosowanych w ich produkcji związków organicznych (zwłaszcza przeciwutleniaczy) ze ścianek przewodów może pogarszać jakość wody wodociągowej. W pracy przedstawiono wyniki badań laboratoryjnych i numerycznych rozprzestrzeniania się butylowanego hydroksytoluenu (BHT) w wodzie, migrującego ze ścianek przewodu z PE-HD. Badania zostały przeprowadzone w zamkniętym układzie laboratoryjnym, w którym krążyła woda ze stałą prędkością przez 72 h. Pomiar zawartości BHT w wodzie wykonano metodą spektometrii mas, natomiast obliczenia modelowe przeprowadzono stosując komercyjny program Fluent (Ansys Inc.), wykorzystując niezbędne dane wejściowe oraz warunki początkowe i brzegowe. Zaobserwowano wyraźny wzrost zawartości BHT w cyrkulującej wodzie, wynikający z migracji tego przeciwutleniacza ze ścianek przewodu z PE-HD do płynącej w nim wody. Uzyskane wyniki obliczeń modelowych zawartości BHT w wodzie wykazały dobrą zgodność z wartościami pomierzonymi w układzie badawczym.
Pipes made of high density polyethylene (HDPE) are widely applied in drinking water distribution systems and household installations. However, the organic com-pounds used for pipe production (especially antioxidants) may migrate from the pipe walls and thus affect the quality of tap water. This paper presents the results of laboratory tests and numerical computations visualizing the propagation of the antioxidant BHT that migrates from the HDPE pipe into the water. Our laboratory test was conducted using a closed-loop setup, where water circulated in the pipe interior with a constant flow velocity for 72 hours. BHT concentration in the water was measured by mass spectrometry, while numerical modeling was carried out using the commercial software Fluent (Ansys Inc.), supported by the input data required, and also the initial and boundary conditions. A noticeable increase was observed in the BHT content of the circulating water, which is attributable to the migration of the antioxidant from the HDPE pipe wall into the flowing water. The values obtained from numerical modeling of BHT concentration in the water were in good agreement with those measured in the laboratory setup.
Źródło:
Ochrona Środowiska; 2012, 34, 3; 33-37
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of tap and hot water treatment before short-term storage on biologically active compounds and sensory quality of wild rocket leaves (Diplotaxis tenuifolia L.)
Autorzy:
Szwejda-Grzybowska, J.I.
Wrzodak, A.
Grzegorzewska, M.
Gajewski, M.
Kosson, R.
Powiązania:
https://bibliotekanauki.pl/articles/2067.pdf
Data publikacji:
2019
Wydawca:
Instytut Ogrodnictwa
Tematy:
hot water
tap water
short-term storage
biological activity
ascorbic acid
polyphenol
antiradical activity
taste
sensory quality
salad rocket
leaf
Diplotaxis tenuifolia
Źródło:
Journal of Horticultural Research; 2019, 27, 2
2300-5009
Pojawia się w:
Journal of Horticultural Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zmian jakości mikrobiologicznej wody w sieci wodociągowej aglomeracji trójmiejskiej.
Microbiological water quality in the water-pipe network of the Gdansk District.
Autorzy:
Sokołowska, A.
Olańczuk-Neyman, K.
Powiązania:
https://bibliotekanauki.pl/articles/236604.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
woda powierzchniowa
woda podziemna
sieć wodociągowa
jakość mikrobiologiczna
bakterie heterotroficzne
tap water
surface water
groundwater
water-pipe network
microbiological quality
heterotrophic bacteria
Opis:
Badaniom mikrobiologicznym i chemicznym poddano wodę wodociągową dostarczaną do mieszkańców aglomeracji trójmiejskiej z dwóch systemów - ujmującego wodę powierzchniową (oczyszczaną w procesach koagulacji, ozonowania i sorpcji na węglu aktywnym) oraz ujmującego wody podziemne (oczyszczane w procesach napowietrzania i filtracji przez złoża katalityczne). Stwierdzono, że w badanych systemach wodociągowych zachodził wtórny wzrost bakterii heterotroficznych, przy czym był on większy w wodzie pochodzącej z ujęcia powierzchniowego dezynfekowanej chlorem lub mieszaniną chloru i dwutlenku chloru, niż w niedezynfekowanej wodzie z ujęć podziemnych. W początkowym odcinku sieci rozprowadzającej oczyszczoną wodę powierzchniową średnia liczba bakterii (niezależnie od środka dezynfekcyjnego) wzrosła o 1log, a na w sieci rozprowadzającej niedezynfekowaną wodę podziemną tylko o 0,5log. Do zasadniczych przyczyn wtórnego wzrostu bakterii w wodzie wodociągowej pochodzącej z ujęcia powierzchniowego należy zaliczyć szybki spadek stężenia chloru pozostałego i duże stężenie tlenu rozpuszczonego, a także prawdopodobnie większą zawartość przyswajalnego węgla organicznego niż wodzie podziemnej. Największy wzrost liczby bakterii, dochodzący do 2log, zanotowano w końcówce sieci rozprowadzającej oczyszczoną wodę powierzchniową w odległości 15,6 km podczas zmiany środka dezynfekcyjnego z chloru gazowego na dwutlenek chloru. W tym czasie stwierdzono znaczący (śr. ponad 3-krotny) wzrost zawartości OWO, prawdopodobnie uwalnianego z osadów na ściankach przewodów wodociągowych oraz spadek stężeń pozostałego chloru i dwutlenku chloru, odpowiednio do średnich wartości 0,03 gCl2/m3 i 0,027 gClO2/m3. Prowadzone obecnie prace badawcze przy użyciu metod bezpośredniego liczenia komórek bakterii z zastosowaniem mikroskopu epifluorescencyjnego, umożliwią określenie całkowitej liczby bakterii, w tym żywych, w wodzie wodociągowej, a także ocenę ich struktury morfologicznej.
The tap water supplied to the inhabitants of Gdansk, Gdynia and Sopot via two distribution systems was analyzed for microbiological and chemical composition. One of the distribution systems involves an intake of surface water treated by coagulation, ozonation and adsorption onto active carbon; the other one uses two intakes of groundwater treated by aeration and filtration through a catalytic bed. In both the distribution systems the regrowth of heterotrophic bacteria was found to occur, which was stronger in the surface water being treated and disinfected (with chlorine, or a mixture of chlorine and chlorine dioxide) than in the groundwater being treated without disinfection. In the initial section of the surface water distribution system the average number of bacteria (regardless of the disinfectant used) increased by 1log, while in the system distributing non-disinfected groundwater an increase of only 0.5log was observed. The underlying causes of bacterial regrowth in the tap water drawn from the surface water intake can be itemized as follows: a rapid decrease in residual chlorine concentration, a high dissolved oxygen concentration and, seemingly, a higher content of assimilable organic carbon as compared to that in the tap water drawn from the groundwater intake. The largest increase in the number of bacteria, up to 2log, was observed in the end section of the system distributing treated surface water, at the distance of 15.6 km, during replacement of gaseous chlorine by chlorine dioxide. This increase was paralleled by a significant (on average more than threefold) rise in the content of TOC (probably released from the deposits on the pipe walls) and by a decrease in the concentrations of residual chlorine and chlorine dioxide to values averaging 0.03 gCl2/m3 and 0.027 gClO2/m3, respectively. Researches are underway, where use is made of direct methods to count bacterial cells (epifluorescence microscope). It is expected that such examinations will make it possible to determine the total number of bacteria (including those survived) in the tap water, as well as to assess their morphological structure.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 15-19
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przyczyny i zapobieganie zmianom jakości wody w systemach wodociągowych
Water Quality Variations in Distribution Systems and Relevant Preventive Measures
Autorzy:
Kowal, A. L.
Powiązania:
https://bibliotekanauki.pl/articles/236438.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
jakość wody
biostabilność
rozwój bakterii
przyswajalny węgiel organiczny
sieć wodociągowa
tap water quality
biostability
bacterial growth
assimilable organic carbon (AOC}
water distribution system
Opis:
W pracy omówiono czynniki wpływające na zmiany jakości wody w systemach jej dystrybucji. Do głównych czynników wpływających na pogorszenie jakości wody wodociągowej zaliczono korozję i gromadzenie osadów, występowanie procesów biochemicznych w sieci, a także raptowne zmiany ciśnienia oraz remonty prowadzone na sieci. Podkreślono szczególną rolę procesów biochemicznych przebiegających w sieci wodociągowej na jakość wody dostarczanej odbiorcom. Rozwojowi bakterii w sieci wodociągowej sprzyja obecność przyswajalnego węgla organicznego w wodzie poddanej w procesie uzdatniania działaniu utleniaczy chemicznych (ozon, dwutlenek chloru, chlor). Do warunków ograniczających rozwój życia biologicznego w wodzie wodociągowej zaliczono m.in. utrzymanie wysokiego stopnia oczyszczania wody (z optymalnym usunięciem zarówno bakterii, jak i węgla organicznego oraz związków azotowych) celem zapewnienia jej biostabilności, utrzymanie w należytej czystości urządzeń technicznych do oczyszczania i gromadzenia wody, płukanie sieci wodociągowej oraz właściwe postępowanie podczas usuwania awarii sieci i urządzeń sieciowych. Przedsiębiorstwa wodociągowe ujmujące wody powierzchniowe powinny wprowadzić do praktyki analitycznej oznaczanie zawartości ogólnego węgla organicznego (OWO), rozpuszczonego węgla organicznego (RWO) oraz przyswajalnego węgla organicznego (PWO) w wodzie tłoczonej do układu dystrybucji.
Of the various contributors to the deterioration of tap water quality, major importance is attached to the corrosive power of the water, the accumulation of suspended solids, the occurrence of biochemical processes in the pipes, as well as rapid pressure variations and frequent damage repairs. In this paper, consideration has been focused on the contribution of the biochemical processes that occur in the water during distribution through the pipe network to the quality of the water supplied to the users. Bacterial growth in the water-pipe network is supported by the presence of assimilable organic carbon (AOC), which persists in the water after treatment with chemical oxidants (ozone, chlorine dioxide, chlorine). But there are also factors limiting microorganism growth in tap water, e.g. a continuingly high treatment efficiency (and this includes an optimal removal of bacteria, organic carbon and nitrogen compounds), biostability assurance, appropriate cleanup of the technical equipment for water treatment and storage, rinsing of the water-pipe network, as well as well-planned and well-organized procedures adopted for damage repair or failure removal. Waterworks with surface-water intakes are supposed to extend the range of analyses by including determinations of total organic carbon (TOC), dissolved organic carbon (DOC) and AOC in the water pumped into the distribution system.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 3-6
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad szybkością zaniku chloru i dwutlenku chloru w wodzie w sieci wodociągowej
Rate of chlorine and chlorine dioxide decay in the water-pipe network
Autorzy:
Domańska, M.
Łomotowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/236588.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
dezynfekcja
chlor
dwutlenek chloru
stała szybkości zaniku dezynfektanta
tap water
disinfection
chlorine
chlorine dioxide
rate constant of disinfectant decay
Opis:
Praca zawiera oryginalne wyniki badań nad szybkością zaniku chloru i dwutlenku chloru w wodzie, wykonanych na próbkach wody pobranych z 14 systemów wodociągowych eksploatowanych na Dolnym Śląsku. Badania wykazały, że w przypadku wody, która ma duże natychmiastowe zapotrzebowanie na chlor, następuje szybszy zanik dwutlenku chloru. Zatem należy zweryfikować tezę, że dwutlenek chloru w systemach wodociągowych ulega wolniejszemu zanikowi, w porównaniu do chloru. Ponadto stwierdzono, że wartość stałej szybkości zaniku dezynfektanta ulega zmianie w czasie transportu wody wodociągowej. Badania przeprowadzone na rurociągu tranzytowym eksploatowanym we Wrocławiu wykazały różnice w kinetyce zaniku chloru i dwutlenku chloru w czasie przepływu wody w sieci wodociągowej. Uzyskane wyniki wskazują na potrzebę prowadzenia indywidualnych badań nad szybkością zaniku dezynfektanta w wodzie w celu prognozowania jego stężenia w całym systemie wodociągowym. Przeprowadzenie takich badań jest niezbędne przy zamianie dezynfektanta, a także przy ustalaniu punktów dodatkowej dezynfekcji wody w rozległych systemach wodociągowych.
This paper presents original results of a study on the rate of chlorine and chlorine dioxide decay in trea-ted water. Samples were taken from 14 water distribution systems which are in service in Lower Silesia. The study has revealed that when the water is characterized by a high 5-minute chlorine demand, the decay of chlorine dioxide occurs at a faster rate. It is therefore necessary to verify the thesis that the decay of chlorine dioxide in the water distribution system proceeds at a slower rate than the decay of chlorine. It has furthermore been observed that the value of the rate constant of disinfectant decay undergoes changes during tap water transport. The investigations into a segment of Wroclaw's water pipeline have revealed differences in the kinetics between chlorine decay and chlorine dioxide decay during water flow in the water-pipe network. The results obtained corroborate the necessity of conducting point tests to determine the local rate of decay for both the disinfectants in the water with the aim to predict their concentrations in the entire water distribution system. Such tests are indispensable when replacing the disinfectant used with another one, or when determining additional disinfection points in large water distribution systems.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 47-49
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane instrumenty ekonomiczne ograniczenia deficytu wody w perspektywie międzynarodowej
Selected economic instruments to limit water deficit in an international perspective
Autorzy:
Thier, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/684656.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
zasoby wodne
kryzys zaopatrzenia w wodę
zwrot kosztów usług wodnych
woda butelkowana
woda wodociągowa
water resources
the crisis of water supply
costs recovery of water services
bottled water
tap water
Opis:
The article presents the issue of water prices for the population in conditions – on one hand – compliance with EU rule on the costs recovery of water services – and the recommendations of the European Union and the UN so as not to pay for water greater load of household income than 4%. In developed countries, this is much easier than in poor countries, where the rate reaches as high as 10%. Among the consequences of the costs recovery of water services principle, the author analyzes trade issues of water in the stock market and the competition between bottled water and tap water.
W artykule przedstawiono kwestię cen wody dla ludności w warunkach, z jednej strony, przestrzegania regulacji UE w sprawie zwrotu kosztów usług wodnych, a z drugiej strony – zaleceń UE i ONZ, aby płatności za wodę nie przekraczały 4% dochodów gospodarstwa domowego. W krajach rozwiniętych jest to o wiele łatwiejsze niż w krajach biednych, gdzie wskaźnik ten sięga nawet 10%. Wśród opisu skutków przestrzegania zasady zwrotu kosztów usług wodnych autorka analizuje zagadnienia związane z handlem wodą na giełdzie oraz konkurencją między wodą mineralną i wodą z kranu.
Źródło:
Gospodarka w Praktyce i Teorii; 2016, 44, 3
1429-3730
2450-095X
Pojawia się w:
Gospodarka w Praktyce i Teorii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Główne przyczyny wtórnego zanieczyszczenia wody w systemie dystrybucji
Major contributors to self-contamination of water in distribution systems
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237133.pdf
Data publikacji:
2006
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
stabilność chemiczna
stabilność biologiczna
biofilm
warunki hydrauliczne
prędkość przepływu wody
korozja
tap water
chemical stability
biological stability
corrosion
hydraulic conditions
flow velocity
Opis:
Przeanalizowano główne przyczyny wtórnego zanieczyszczenia wody w systemie dystrybucji. Scharakteryzowano brak stabilności chemicznej i biologicznej wody wprowadzanej do sieci wodociągowej, zapewnienie odpowiedniej zawartości dezynfektanta oraz zmienne warunki hydrauliczne panujące w systemie dystrybucji. Wykazano, że brak stabilności chemicznej wody sprzyja intensyfikacji korozji przewodów wodociągowych oraz gromadzeniu osadów na powierzchni rurociągów, a w konsekwencji - jej wtórnemu zanieczyszczeniu produktami korozji. Stwierdzono, że wzrost porowatości i chropowatości przewodów wodociągowych sprzyja rozwojowi mikroorganizmów w biofilmie. Obecność substratów pokarmowych w wodzie warunkuje rozwój mikroorganizmów, wzrost intensywności rozwoju biofilmu oraz poziomu wtórnego skażenia wody drobnoustrojami. O stopniu wtórnego zanieczyszczenia wody i ilości uwalnianych składników osadów zgromadzonych w przewodach wodociągowych decydują ponadto warunki hydrauliczne panujące w systemie dystrybucji wody.
The main contributory factors in the self-contamination of the water pumped into the distribution system can be itemized as follows: lack of chemical and biological stability of the water itself, inadequate amount of the disinfecting agent, and variability of the hydraulic conditions in the distribution system. There is evidence that the lack of chemical stability supports the development of corrosion in the water-pipe network and stimulates encrustation growth on the pipe surface, thus contributing to self-contamination of the water with corrosion products. The rise in pipe porosity and wall roughness was found to favour microbial growth in the biofilm. The presence of nutrients in the water, which accounts for microbial growth, increases the rate of biofilm growth and raises the level of self-contamination of the water with microorganisms. The extent of self-contamination and the amount of the encrustation components released in the water pipes are also noticeably influenced by the hydraulic conditions in the distribution system.
Źródło:
Ochrona Środowiska; 2006, R. 28, nr 4, 4; 29-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka metod zapobiegania powstawaniu bromianów(V) w wodzie przeznaczonej do spożycia
Characteristics of bromate formation prevention methods in water intended for human consumption
Autorzy:
Olsińska, U.
Powiązania:
https://bibliotekanauki.pl/articles/236674.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
tap water
bromate formation control
bromide removal
ozonation optimization
water ammonification
H2O2 dosing
woda do spożycia
bromiany
zapobieganie
usuwanie bromków
optymalizacja ozonowania
amonizacja wody
dawkowanie H2O2
Opis:
Bromate content following ozonation of bromide-containing water may range from 0.4 to 60 mgBrO3–/m3. Based on toxicological studies, bromates are classified as potential human carcinogens and are subject to legal regulations in many countries. In Europe, since the 25th of December 2008 their maximum permissible content in water intended for human consumption must not exceed 10 mgBrO3–/m3. As bromates are stable compounds, difficult to remove using conventional water treatment technologies, novel techniques to control their formation in water need to be developed. Technologies meant to control the bromate content in water can be divided into two groups: (1) methods allowing limitation of bromate formation and (2) methods for bromate removal. Methods that may be applied to control the bromate formation in water intended for human consumption are briefly reviewed herein. Evaluation of progress in their development was performed as well as feasibility of their application in water treatment systems was assessed. The review outlines both the well-known methods (e.g. lowering of pH, water ammonification, bromide removal in conventional water treatment processes, operational parameter optimization, multi-stage ozonation, addition of OH radical scavengers, hydrogen peroxide dosing) and the novel ones (e.g. membrane processes for bromide removal, catalytic ozonation, strong oxidant dosing). Selection of an appropriate solution to the problem of increased bromate presence in water should always be preceded by pilot studies. The main reasons include a complex mechanism of bromate formation and simultaneous effect of various water quality indicators on the effectiveness of different bromate formation prevention methods.
Zawartość bromianów(V) po procesie ozonowania wody zawierającej bromki może sięgać od 0,4 mgBrO3–/m3 do 60 mgBrO3–/m3. Na podstawie wyników badań toksykologicznych bromiany(V) zostały zakwalifikowane do grupy potencjalnych kancerogenów i są przedmiotem regulacji prawnych w wielu krajach. W Europie, od 25 grudnia 2008 r., ich maksymalna dopuszczalna zawartość w wodzie przeznaczonej do spożycia nie może przekraczać 10 mgBrO3–/m3. Ponieważ bromiany(V) są związkami trwałymi i trudno usuwalnymi za pomocą konwencjonalnych procesów oczyszczania wody, dlatego niezbędne jest opracowanie nowych technik kontroli ich powstawania w wodzie. Technologie przydatne do kontroli zawartości bromianów(V) w wodzie można podzielić na dwie grupy: (1) metody umożliwiające ograniczenie powstawania bromianów(V), (2) metody usuwania bromianów(V). W pracy omówiono metody, które mogą być wykorzystane do kontroli powstawania bromianów(V) w wodzie przeznaczonej do spożycia przez ludzi. Dokonano także oceny postępu w ich opracowaniu, jak również możliwości ich stosowania w systemach oczyszczania wody. W rozważaniach uwzględniono zarówno metody dobrze znane (np. obniżenie wartości pH wody, amonizacja wody, usuwanie bromków w konwencjonalnych procesach oczyszczania wody, optymalizacja parametrów procesowych, ozonowanie wieloetapowe, dawkowanie akceptorów rodników OH, dawkowanie nadtlenku wodoru), jak i nowsze (zastosowanie technik membranowych do usuwania bromków, ozononowanie katalityczne oraz dawkowanie silnych utleniaczy). Wybór właściwego rozwiązania problemu zwiększonej obecności bromianów(V) w wodzie, ze względu na złożony mechanizm ich tworzenia i jednoczesny wpływ wielu wskaźników jakości wody na skuteczność poszczególnych metod zapobiegania ich powstawaniu, powinien być zawsze poprzedzony badaniami pilotowymi.
Źródło:
Ochrona Środowiska; 2017, 39, 2; 17-26
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba oceny wpływu rur wodociągowych z tworzyw sztucznych na wybrane właściwości organoleptyczne wody
An attempt at evaluation of impact of plastic water supply pipelines on selected organoleptic properties of water
Autorzy:
Kowalska, B.
Guz, Ł.
Musz-Pomorska, A.
Widomski, M. K.
Powiązania:
https://bibliotekanauki.pl/articles/236598.pdf
Data publikacji:
2016
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
jakość wody wodociągowej
polietylen
poli(chlorek winylu)
liczba progowa zapachu (TON)
liczba progowa smaku (TFN)
tap water quality
polyethylene
poly(vinyl chloride)
threshold odor number (TON) threshold flavor number (TFN)
Opis:
Migracja substancji organicznych ze ścianek przewodu polimerowego do wody wodociągowej może prowadzić do pogorszenia jej właściwości organoleptycznych, a zwłaszcza zapachu i smaku. Zaprezentowane badania miały na celu wyznaczenie wartości progowej liczby zapachu (TON) oraz progowej liczby smaku (TFN) w przypadku wody mającej kontakt z przewodami wodociągowymi wykonanymi z tworzyw sztucznych. Do badań wybrano rury wykonane z nieplastyfikowanego polichlorku winylu (PVC-U) (33,4 mm × 2,2 mm), polietylenu dużej gęstości (PE-HD) (32 mm × 2,4 mm) oraz polietylenu sieciowanego (PEX-b) (28,6 mm × 3,2 mm). Zastosowana procedura badawcza obejmowała przemywanie próbek przewodów wodą ultraczystą przez 1 h, przetrzymywanie próbek w wodzie ultraczystej przez 24 h w temperaturze 23°C, test na migrację zanieczyszczeń w czasie 72 h (wg EN 1420-1:1999), rozcieńczanie oraz ocenę wartości TON i TFN metodą pełną, parzystą, wyboru niewymuszonego (wg EN 1622:2006). W skład zespołu oceniającego smak i zapach wody wchodziło 5 osób, badania przeprowadzono w trzech powtórzeniach. Obliczona średnia wartość TON zawierała się w przedziale 3÷5, zaś TFN – 3÷6, przy czym największą wartość zaobserwowano w przypadku kontaktu wody z PE-HD, zaś najmniejszą – PVC-U. Wykazano, że spośród analizowanych materiałów polimerowych największy wpływ na właściwości organoleptyczne wody miał polietylen dużej gęstości, zaś najmniejszy – poli(chlorek winylu).
Migration of organic substrates from polymer pipelines to tap water may result in deterioration of organoleptic water properties, especially its odor and flavor. The aim of the presented studies was to determine the threshold odor number (TON) and threshold flavor number (TFN) for water after its contact with plastic water supply pipelines. Unplasticized polyvinyl chloride PVC-U (33.4 mm×2.2 mm), high density polyethylene PE-HD (32 mm×2.4 mm) and cross-linked polyethylene PEX-b (28.6 mm×3.2 mm) were selected for studies. The analysis procedure covered pipe sample flushing with ultra pure water for 1 hour, sample storage in ultra pure water for 24 hours at 23°C, test for contaminant migration within 72 h (according to EN 1420-1:1999), dilution, and TON and TFN assessment by the complete and even method of the unforced choice (according to EN 1622:2006). The odor and flavor testing team consisted of 5 individuals, the measurements were repeated 3 times. The average calculated TON was in the range of 3–5 while TFN – 3–6. The highest value was observed for PE-HD and the lowest for PVC-U. Our studies demonstrated that PE-HD had the highest influence on organoleptic properties of water among the analyzed polymer materials, while the lowest influence was observed for PVC-U.
Źródło:
Ochrona Środowiska; 2016, 38, 1; 53-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania higieniczno-sanitarne rzeki Wisły w rejonie Warszawy
Gigienichno-sanitarnye issledovanija vod reki Visly v raione Varshavy
Sanitary and hygienic investigations of Vistula River within Warsaw region
Autorzy:
Cabejszek, I.
Koziorowski, B.
Malanowski, Z.
Stanislawska, J.
Powiązania:
https://bibliotekanauki.pl/articles/875535.pdf
Data publikacji:
1957
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
wody wodociagowe
wody opadowe
stan higieniczno-sanitarny
scieki komunalne
pomiary hydrometryczne
rzeka Wisla
rejon warszawski
badania higieniczne
badania sanitarne
badania bakteriologiczne
ujecia wody
zanieczyszczenia wod
stan czystosci wod
strefy ochronne
oczyszczanie sciekow
tap water
precipitation water
sanitary-hygienic assessment
municipal sewage
hydrometric measurement
Vistula River
Warsaw region
bacteriological research
water intake
water pollutant
water purity
protection zone
sewage treatment
Źródło:
Roczniki Państwowego Zakładu Higieny; 1957, 08, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-42 z 42

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies