Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tap water" wg kryterium: Temat


Tytuł:
Environmental factors affecting the survival of soil dwelling Legionella longbeachae in water
Autorzy:
Potočnjak, Mia
Magdalenić, Zlatko
Dijan, Marija
Rebić, Danica
Gobin, Ivana
Powiązania:
https://bibliotekanauki.pl/articles/990884.pdf
Data publikacji:
2016
Wydawca:
Instytut Medycyny Wsi
Tematy:
legionella
survival
stagnant tap water
temperature
Opis:
Introduction. Legionella longbeachae, a causative agent of Legionnaire’s disease, has often been associated with potting soil and gardening, a feature quite distinct from other Legionella species. The precise transmission mechanism is still unknown, although due to the ecological coherence of the soil and water there is a potential risk of infection by contaminated stagnant water in the garden. Objective. The aim of the study was to explore the ability of L. longbeachae to survive in stagnant tap water usually used for watering in gardens. The influence of different factors (temperature, pH and NaCl concentration) on L. longbeachae survival in stagnant tap water was also tested. Results. The result showed that L. longbeachae is viable in stagnant tap water over 100 days at 4 °C and 25 °C. The survival of L. longbeachae exposed to different pH and NaCl concentration suggests resistance to low pH values (pH2 and pH5) and all tested NaCl concentrations at temperatures lower than 25 °C. The ability of L. longbeachae to persist in stagnant tap water should be taken seriously in the risk assessments as a possible hidden reservoir of infection.
Źródło:
Annals of Agricultural and Environmental Medicine; 2016, 23, 3
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemistry of tap water in selected localities on South Podlasie Lowland
Chemizm wody wodociągowej w wybranych miejscowościach niziny południowopodlaskiej
Autorzy:
Kalembasa, D.
Jaremko, D.
Becher, M.
Pakuła, K.
Stefański, K.
Powiązania:
https://bibliotekanauki.pl/articles/125944.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
tap water chemistry
ICP-AES
quality indicators of tap water
chemizm wody wodociągowej
wskaźniki jakości wody wodociągowej
Opis:
The aim of this paper is presentation of results of chemical composition of tap water in selected localities on South Podlasie Lowland. Samples of water were taken from water treatment station and taps situated in various parts of Lukow, Sokolow Podlaski and selected localities in Lochow, Wierzbno and Mokobody commune. Quarterly investigations covered analysis of water reaction (pH) by potentiometric method, electrical conductivity (EC) by electrochemical method and total concentration of 26 elements by inductively coupled plasma atomic emission spectrometry (ICP-AES). It was found that untreated waters being the source of tap water in selected localities on South Podlasie Lowland contained excessive iron and manganese amounts, that were efficiently removed during the treatment. Concentration of analyzed elements in treated water did not exceed the permissible limits and quality of analyzed tap water changed a little during its transport due to the secondary contamination.
Celem niniejszej pracy jest przedstawienie wyników analizy składu chemicznego wody wodociągowej dostarczanej mieszkańcom wybranych miejscowości Niziny Południowopodlaskiej. Punkty pobrania próbek do badań wyznaczono na wyjściu ze stacji uzdatniania oraz w kurkach czerpalnych, położonych w różnych dzielnicach Łukowa i Sokołowa Podlaskiego, a także w różnych miejscowościach gmin Łochów, Wierzbno i Mokobody. Próbki wody pobierano w odstępach kwartalnych. W pobranych próbkach oznaczono odczyn (pH) wody metodą potencjometryczną, przewodnictwo właściwe metodą elektrochemiczną oraz stężenie K, Ca, Mg, Na, S, Fe, Mn, B, Li, Ba, Sr, Cu, Zn, Ni metodą optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie sprzężonej indukcyjnie (ICP-AES). Stężenie pierwiastków objętych badaniami na ogół nie przekraczało obowiązujących wartości dopuszczalnych. Sporadycznie odnotowano podwyższone wartości analizowanych parametrów w próbkach wody pobieranych w kurkach czerpalnych, wskazujące na zanieczyszczenie wody w systemie dystrybucji. W wodzie surowej stwierdzono ponadnormatywne stężenia żelaza i manganu, ale pierwiastki te były skutecznie usuwane w procesie uzdatniania.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 523-528
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acanthamoeba in the Domestic Water Supply of Huntington, West Virginia, U.S.A.
Autorzy:
Trzyna, Wendy
Mbugua, Margaret W.
Rogerson, Andrew
Powiązania:
https://bibliotekanauki.pl/articles/763579.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Jagielloński. Wydawnictwo Uniwersytetu Jagiellońskiego
Tematy:
Amoebic Keratitis, amoebae, tap water, Acanthamoeba, chlorine tolerance
Opis:
The aim of this study was to determine the prevalence of Acanthamoeba in the domestic water supply in Huntington, West Virginia (U.S.A.) and the factors that may contribute to their presence or absence. One hundred sixty-two one liter tap water samples were collected over eight months. Amoebae in the samples (cysts or trophozoites) were harvested by passively filtering onto 5 μm pore size filters and enriching for amoebae on non-nutrient amoeba saline agar plates seeded with Escherichia coli for cultivation. Thirteen percent of all samples were positive for amoebae and 9.3% were positive for the amoeba of interest, Acanthamoeba. Chlorine levels were determined for samples at the time of collection, yielding a mean level of 1.56 mg l–1 chlorine in the distribution system ca. 8 kilometers from the water treatment plant. Cysts and trophozoites of Acanthamoeba clonal isolates were found to tolerate up to 50 mg l–1 and 4 mg l–1 chlorine respectively. This study showed that Acanthamoeba were present in the domestic water supply in Huntington, WV and although no attempt was made to count cells in liter samples, their frequency of occurrence (9.3%) and failure to be present in all replicates, suggests they were present at background levels of perhaps a few cells per five liters. This is only the second U.S. study to consider amoebae in tap water and is unique since the source water was river water. Acanthamoeba trophozoites and cysts were able to withstand levels of chlorine higher than those typically found in tap water suggesting they may be present in either form in the distribution system. Acanthamoeba are opportunistic pathogens capable of causing eye infections and their presence in tap water is a potential risk factor for susceptible individuals, particularly contact lens wearers who may use tap water to clean lenses and storage cases.
Źródło:
Acta Protozoologica; 2010, 49, 1
1689-0027
Pojawia się w:
Acta Protozoologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mętność wody dostarczanej przez systemy wodociągowe województwa małopolskiego.
Turbidity of water provided by the water supply systems in the Malopolskie Voivodeship.
Autorzy:
Bergel, T.
Pawełek, J.
Rułka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/236546.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
jakość wody
mętność
tap water
water quality
turbidity
Opis:
W pracy dokonano analizy mętności wody dostarczonej odbiorcom w 2007 r. przez systemy wodociągowe w województwie małopolskim. W analizie uwzględniono wszystkie zakłady wodociągowe, które są objęte monitoringiem kontrolnym i przeglądowym przez wojewódzkie służby sanitarno-epidemiologiczne - łącznie 703. W badaniach obejmujących analizę 1794 próbek wody, w tym 167 próbek wody powierzchniowej, 1261 - wody podziemnej i 366 - wody mieszanej, określono mętność minimalną, maksymalną i średnią oraz liczbę przekroczeń mętności dopuszczalnej (1 NTU). Przeprowadzona analiza wykazała, że mętność wody wodociągowej, w zależności od źródła wody, wynosiła: wody powierzchniowe 0,1÷8,7 NTU (śr. 0,97 NTU), wody podziemne 0,01÷26,0 NTU (śr. 0,84 NTU), wody mieszane 0,02÷10,0 NTU (śr. 0,93 NTU). Najwięcej przekroczeń mętności dopuszczalnej odnotowano w wodociągach korzystających z wód powierzchniowych - 29,3% analizowanych próbek, a znacznie mniej w korzystających z wód podziemnych - 12,4% i mieszanych - 4,1%. Przekroczenia te w przeważającej większości przypadków mieściły się w przedziale 1÷5 NTU.
The water supplied to the users in the Malopolskie Voivodeship in 2007 was analyzed for turbidity. The analysis covered 703 waterworks regularly monitored by the Regional Sanitary and Epidemiological Station. A total of 1794 water samples was made subject to analysis (167 surface water samples, 1261 groundwater samples and 366 mixed water samples) to determine the minimal, maximal and average turbidity levels, as well as the number of episodes when the admissible turbidity value (1 NTU) was exceeded. The study has produced the following findings. According to the water source being used, the turbidity of the tap water supplied varied from 0.1 to 8.7 NTU (av. 0.97 NTU) for surface water, from 0.01 to 26.0 NTU (av. 0.84 NTU) for groundwater, and from 0.02 to 10.0 NTU (av. 0.93 NTU) for mixed water. The majority of episodes with the 1 NTU value being exceeded were observed in the waterworks using surface water (29.3% of samples). Significantly lower was the number of such episodes in the waterworks where use was made of groundwater (12.4% of samples) or mixed water (4.1% of samples). In most instances the exceeded turbidity values were within the range of 1 to 5 NTU.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 61-64
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie heterotroficznych bakterii z rodzaju Aeromonas w wybranym systemie dystrybucji wody
Occurrence of heterotrophic bacteria of the genus Aeromonas in a water distribution system: A case study
Autorzy:
Kręgiel, D.
Rygała, A.
Powiązania:
https://bibliotekanauki.pl/articles/237313.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
biofilm
adhezja
luminometria
tap water
adhesion
luminometry
Opis:
Hetrotroficzne bakterie Aeromomas sp występują powszechnie w środowisku wodnym, a niektóre z nich są patogenami dla ludzi i ryb. Występowanie bakterii Aeromonas hydrophila badano w systemie dystrybucji wody podziemnej, nie poddanej chlorowaniu. Badania przeprowadzono systematycznie w ciągu całego roku. Stwierdzono, że bakterie z rodzaju Aeromonas były wykrywane w wodzie wodociągowej w miesiącach letnich, od maja do października, przy czym największy wzrost liczby bakterii wynoszący 156 jtk/100 cm3 odnotowano w sierpniu. Około 80% wyizolowanych szczepów, wykazujących zdolność [beta]-hemolizy, zidentyfikowano jako Aeromonas hydrophila. Wyizolowane bakterie adherowały do powierzchni PVC, materiału powszechnie stosowanego w instalacjach wodociągowych. Biorąc pod uwagę zarówno silne właściwości adhezyjne Aeromonas sp., które stymulują tworzenie biofilmu, jak i możliwość występowania różnych czynników wirulencji warunkujących ich chorobotwórczość, należy rozważyć włączenie pałeczek z rodzaju Aeromonas do rutynowych badań mikrobiologicznych wody, a zwłaszcza do monitoringu funkcjonowania sieci i urządzeń wodociągowych.
Heterotrophic strains of Aeromonas sp. are ubiquitous in aquatic environments, but some of them have a pathogenic impact on humans and fish. Samples were taken regularly over a one-year period from a system distributing unchlorinated groundwater, which was analyzed for the presence of Aeromonas hydrophila. Bacteria of the genus Aeromonas were detected in tap water samples collected from May to October, the largest increase in the number of these bacteria (156 cfu/100 cm3) being observed in August. Approximately 80% of the isolated strains, with a capacity for [beta]-hemolysis, were identified as Aeromonas hydrophila. The bacteria showed the ability to adhere to the surface of PVC, a material widely used in water-supply systems. Taking into account, on the one hand, the strong adhesion properties of Aeromonas sp., which stimulate biofilm formation, and considering, on the other hand, the occurrence of various virulence factors that underlie the pathogenicity of Aeromonas sp., it seems recommendable to include rods of the genus Aeromonas not only into routine microbiological analysis of tap water, but also into the monitoring of the functioning of water distribution systems.
Źródło:
Ochrona Środowiska; 2010, 32, 4; 47-50
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Natural radioactivity in tap water samples for selected regions in Thi-Qar Governorate - Iraq
Autorzy:
Hadi, Hasan A.
Karim, Mahmood S.
Mahi, Ali T.
Abood, Tareq H.
Powiązania:
https://bibliotekanauki.pl/articles/1192660.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
(HPGe) detector
Thi-Qar governorate
tap water
specific activity
radionuclides
Opis:
In the present work, we have measured specific activity concentrations in ten tap water samples for selected regions in Thi-Qar governorate by using high purity germanium (HPGe) detector. The results have shown that, the specific activity, for 238U was ranged from (0.65±0.8 Bq/kg) in AL- Nasir region to (1.32±0.7.8 Bq/kg) in AL-Refai region, for 232Th the specific activity was ranged from (0.120±0.34 Bq/kg) in AL-Garraf region to (0.980±0.99 Bq/kg) in AL- Dwaya region, for 40K the specific activity was ranged from (13.33±3.6 Bq/kg) in AL-Nasir region to (38.54±6.2 Bq/kg) in (AL-Garraf) region, with an average values of (0.933±0.16 Bq/kg), (0.737±0.17 Bq/kg), (24.451±7.5Bq/kg), for 238U, 232Th and 40K, respectively. In order to asses the radiological hazards of the radioactivity in tap water, we have been calculated the parameters (Raeq , DƔ, AEDin , AEDout , EAD , Iɣ , Hin and Hex).
Źródło:
World Scientific News; 2016, 47, 2; 112-122
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamics of water consumption changes in a tourist resort
Autorzy:
Bartkowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/125041.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
indicators
tap water
variation trends
water consumption
water requirement index
water supply system
Opis:
This work presents problems related to the water consumption in the city of Olecko situated in the north-east part of Poland in the Warmińsko-Mazurskie Province of the country, at the eastern border of the Mazurian Lake District along the trail connecting the land of the Large Mazurian Lakes with the Suwalsko-Augustowskie Lake District. Over 2011–2012 water extraction to the municipal water supply network was studied. The volume of water extracted every day was analyzed and the gathered volumes were analyzed statistically. The varying water extraction was also studied. The obtained results were presented in a graphic form. Basing on the descriptive stats and prepared diagrams certain general conclusions were drawn and the collected study figures and facts were summed up. This allowed to determine days of the highest and lowest water consumption. Also months of extreme water extraction and consumption were determined. The water extraction ranged from 1641 m3/24h to 2607 m3/24h, at an average value of 2077.4 m3/24h. Over the period under study the day of the largest water extraction and consumption was in July and the day of the lowest water extraction and consumption in December. During a week inhabitants used the highest water amount on Saturdays and the lowest on Sundays and other feast-days. Basing on the conducted measurements also the coefficient of water consumption per capita was determined. The fluctuation of this coefficient was identical as that for the water consumption. Within the period of study it ranged from 73.3 l/M 24h to 116.5 l/M 24h. The average value of the specific water consumption was 92.8 l/M 24h. For the sake of discussion the obtained results were compared with observations across the country.
Źródło:
Journal of Ecological Engineering; 2014, 15, 4; 46-54
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skutki braku stabilności biologicznej wody wodociągowej
Lack of Biological Stability and the Implication it has for Tap Water Quality
Autorzy:
Świderska-Bróż, M.
Powiązania:
https://bibliotekanauki.pl/articles/236444.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
stabilność biologiczna
biofilm
tap water quality
biological stability
Opis:
Omówiono parametry składu wody oraz procesy oczyszczania współdecydujące o jej biologicznej stabilności. Wykazano, że brak stabilności biologicznej wody wprowadzanej do sieci wodociągowej jest jedną z głównych przyczyn wtórnego fizyczno-chemicznego i bakteriologicznego zanieczyszczenia wody wodociągowej podczas jej transportu do odbiorców. Wykazano, że w wodzie niestabilnej biologicznie przebiegają takie zjawiska, jak wtórny rozwój mikroorganizmów unoszonych z wodą lub zasiedlających wewnętrzne powierzchnie przewodów wodociągowych (tzw. biofilm), biokorozja intensyfikująca korozję elektrochemiczną metali, hamowanie powstawania powłok antykorozyjnych, bądź ich rozpuszczanie, zwiększone zużycie środków dezynfekcyjnych i uwalnianie produktów korozji metali do wody. Zjawiska te są powodem wtórnego zanieczyszczenia wody podczas jej przebywania w systemie wodociągowym.
The parameters of the water composition and the treatment processes contributing to its biological stability are specified. It has been shown that the lack of biological stability of the water entering the pipe network is one the major factors responsible for the recontamination (both physicochemical and bacteriological) of the tap water during transport to the users. Biologically unstable water favours the occurrence of the following phenomena: regrowth of microorganisms floating in the water or colonizing the pipe interior (biofilm), biocorrosion enhancing the electrochemical corrosion of metals, inhibition of anticorrosive film formation, solubilization of anticorrosive films, release of metal corrosion products into the water, etc. They all are contributions to the recontamination of water during residence in the water supply system.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 7-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of using borehole heat exchangers in Macedonia and in Poland
Autorzy:
Kowalski, T.
Ruvceska, A.
Śliwa, T.
Bieda, A.
Powiązania:
https://bibliotekanauki.pl/articles/298667.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
borehole heat exchangers
geothermal energy
heat pump
hot tap water
Opis:
Using borehole heat exchangers for heating and cooling in different climate conditions were analysed and compared in this paper, considering the heating and cooling modes of the heat pump. Economic analysis were made according to the energy demand for heating, cooling and hot tap water with borehole heat exchangers for a typical family house. The costs for running borehole heat exchangers in Macedonia and Poland were also based on the average monthly temperatures and geological profile of the location.
Źródło:
AGH Drilling, Oil, Gas; 2017, 34, 1; 141-156
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem wtórnego zanieczyszczenia wody w województwie śląskim
The problem of secondary pollution of water in the Silesian region
Autorzy:
Puszczało, Ewa
Marszałek, Anna
Powiązania:
https://bibliotekanauki.pl/articles/125872.pdf
Data publikacji:
2020
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
woda wodociągowa
uzdatnianie wody
wtórne zanieczyszczenie
tap water
second water pollution
water treatment
Opis:
Woda z wodociągu pod względem bakteriologicznym oraz chemicznym musi spełniać wymagania stawiane wodzie do picia. Zakłady wodociągowe mają obowiązek stale kontrolować jakość dostarczanej wody. Wyniki badań zamieszczone na stronie Zakładu Wodociągów i Kanalizacji w Gliwicach potwierdzają dobrą jakość wody w Gliwicach. Jednak zanim woda znajdzie się w naszym kranie, przechodzi drogę wodociągami. Gdy na zamieszkiwanym przez nas osiedlu znajdują się stare rury albo mieszkamy w domu, w którym rury nie były wymieniane przez wiele lat, w wodzie mogą pojawiać się szkodliwe związki. Ponadto woda wodociągowa może odznaczać się dużą twardością. Jest to najczęstsza przyczyna powstawiania kamienia, który dodatkowo znacznie obniża smak wody z kranu. Aby poprawić jakość wody wodociągowej, konsumenci stosują urządzenia filtrujące wodę z kranu lub kupują wodę butelkowaną. W artykule przedstawiono badanie ankietowe techniką wyboru przypadkowego na wybranej grupie 200 mieszkańców w średnim wieku w mieście Gliwice w czerwcu 2019 roku. Głównym celem pracy było przedstawienie opinii mieszkańców na temat oczekiwań związanych z poprawą jakości wody z kranu.
In terms of bacteriology and chemistry, the tap water must meet the requirements for drinking water. Water utilities (waterworks) are required to constantly monitor the quality of supplied water. Test results posted on Department of Waterworks and Sewerage in Gliwice website confirm good water quality in Gliwice. However, before the water reaches our tap, it goes through the waterworks. When old pipes are found in the housing estate we live in or we live in a house where pipes have not been changed for many years, harmful compounds may appear in the water. In addition, tap water can be characterized by high hardness. This is the most common cause of stone formation, which further significantly reduces the tap water taste. To improve the quality of tap water, consumers use tap water filtering devices or buy bottled water. This article presents a survey using a random selection technique on a selected group of 200 middle-aged residents in the city of Gliwice in June 2019. The main goal was to present residents' opinions on the need to improve tap water quality.
Źródło:
Proceedings of ECOpole; 2020, 14, 1; 129-134
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skład chemiczny wody w siedleckiej sieci wodociągowej
Chemical composition of drinking water in Siedlce
Autorzy:
Kalembasa, D.
Jaremko, D.
Powiązania:
https://bibliotekanauki.pl/articles/338793.pdf
Data publikacji:
2008
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ICP-AES
makro- i mikroelementy
woda wodociągowa
macro- and microelements
tap water
Opis:
W pracy przedstawiono wyniki badań składu chemicznego wody wodociągowej w mieście Siedlce. Punkty pobierania próbek do badań wyznaczono na wyjściu ze stacji uzdatniania, skąd woda jest kierowana do sieci miejskiej, oraz w 18 kurkach czerpalnych położonych w różnych dzielnicach miasta. Próbki wody pobrano w czterech terminach, w odstępach kwartalnych, w latach 2004/2005. Badano w nich zawartość 26 pierwiastków metodą ICP-AES. Uzyskane dane opracowano statystycznie. Stwierdzono, że jakość wody uzdatnionej przekazywanej do systemu dystrybucji w Siedlcach spełnia wszystkie normy w zakresie wskaźników objętych badaniami. Jej jakość w wyniku wtórnego zanieczyszczenia ulega niewielkiej zmianie w czasie transportu. Nie zaobserwowano znacznych przekroczeń dopuszczalnych stężeń składników mineralnych w próbkach wody, a niewielkie ponadnormatywne ilości wystąpiły w małej liczbie analizowanych próbek.
Results of chemical analyses of the tap water in Siedlce are presented in this paper Samples of water were taken from water treatment station and from eighteen taps situated in various parts of the town. Quarterly investigations included analysis of total concentrations of twenty six elements by inductively coupled plasma atomic emission spectrometry (ICP-AES). The resulting data were processed statistically. It was found that treated water in Siedlce water supply system meets the requirements for drinking water. Quality of water slightly worsens during transport due to secondary contamination, but this happened sporadically.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2008, T. 8, z. 2a; 81-86
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nierównomierności rozbioru wody wodociągowej na zmianę jej jakości
Tap water quality variations due to the irregularity of partition
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236344.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
system dystrybucji
jakość wody
wtórne zanieczyszczenie
water supply system
tap water
recontamination
Opis:
Przedstawiono wyniki badań wpływu nierównomierności rozbioru wody w budynku na zmiany jej składu fizyczno-chemicznego w instalacjach wodociągowych. Wykazano, że wzrost poboru wody był przyczyną pogorszenia jakości wody, głównie w zakresie barwy, mętności i zawartości żelaza ogólnego. Wzrost rozbioru wody, a tym samym prędkości przepływu wody, powodował wymywanie zanieczyszczeń z wewnętrznych powierzchni rurociągów. Stwierdzono, że wśród uwalnianych zanieczyszczeń dominowały koloidy i zawiesiny, dlatego poziom zanieczyszczenia wody był proporcjonalny do stężenia żelaza nierozpuszczonego, natomiast nie stwierdzono wpływu nierównomierności rozbioru wody na poziom organicznego zanieczyszczenia wody.
The objective of the study was to analyze the problem of how the irregularity of water partition affects the physicochemical composition of the tap water. It was found that the rise in water consumption accounted for the deterioration of water quality in terms of colour, turbidity, and total iron concentration. The increased partition of the water, as well as the resulting rise in flow velocity, washed away the pollutants from the internal surfaces of the pipes. Among the released pollutants, colloids and suspended solids were found to dominate, and that is why the water pollution level was proportional to the concentration of insol iron. The irregularity of partition had no effect whatsoever on the level of pollution by organic matter.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 4, 4; 21-23
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność filtracji dzbankowej w zmiękczaniu wody wodociągowej i usuwaniu chloru
Performance of jug filtration in tap water softening and chlorine removal
Autorzy:
Kamińska, Gabriela
Puszczało, Ewa
Marszałek, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2163402.pdf
Data publikacji:
2022
Wydawca:
Akademia Techniczno-Humanistyczna w Bielsku-Białej
Tematy:
filtry dzbankowe
woda wodociągowa
twardość wody
chlor
jug filters
tap water
water hardness
chlorine
Opis:
Water hardness, taste, smell, and color are the most important tap water parameters for consumers. Microbiological and physicochemical parameters of tap water should not exceed the permissible values listed in Regulation of Ministry of Health on the quality of water intended for human consumption. Tap water parameters are regularly monitored, however periodically, deviations are allowed, which make it possible to supply water that does not meet the requirements of quality standards. Such a situation causes that consumers have doubts about the health safety of the supplied water. The organoleptic properties of the water such as taste, smell and color can be easily improved at home using jug filters. In this study, we tested the effectiveness of eight inexpensive and easily available jug water filters to soften and remove chlorine from water. Filters were labeled with symbols A, B, C, D, E, F, G, H. Experiments were performed with model water, which was prepared from drinking water taken directly from a sink and spiked with hypochlorite sodium. The hardness of model water was 7.5 mval/L, while free chlorine concentration was equaled 1.1 mg/L. 200 L of model water was filtered by each filter in duplicates. It was found that jug filtration is an effective method for removal of chlorine from water, provided that a use of proper filter. Although, all used filters are dedicated to removal of chlorine from water, not all of them represented a sufficient removal of chlorine. Filters A, B and C were the most effective for chlorine removal. For these filters, chlorine concentration was reduced to the value of 0.075 mg/L. Moreover, for filters A, B, C and E, the concentration of chlorine in the filtrates remained relatively similar throughout the entire experiment. Filters D and H represented the poorest efficiency of chlorine removal. Concentration of chlorine in these filtrates exceeded permissible value recommended by Regulation of Ministry of Health. Among eight studied filters (i.e. 0.3 mg/L), filters A and B are considered as the most effective for water softening. Generally, the efficiency of jug filtration in water softening was at mediocre level and decrease in time. It could have been caused by the high initial hardness of tap water in Gliwice. In the case of very hard water, more often than recommended by the manufacturers replacing the filter cartridges is recommended.
Źródło:
Polish Journal of Materials and Environmental Engineering; 2022, 4(24); 13-20
2720-1252
Pojawia się w:
Polish Journal of Materials and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ spadku zużycia wody w miastach zaopatrywanych z wodociągu grupowego Górnośląskiego Przedsiębiorstwa Wodociągów w Katowicach na jakość wody w systemie dystrybucji
Effect of the Decrease in the Consumption of Water on its Quality in the Water Distribution System of Upper Silesia
Autorzy:
Kuś, K.
Grajper, P.
Ścieranka, P.
Wyczarska-Kokot, J.
Zakrzewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/236376.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system zaopatrzenia w wodę
zużycie wody
jakość wody
water supply system
water consumption
tap water quality
Opis:
Wodociąg grupowy Górnośląskiego Przedsiębiorstwa Wodociągów (GPW) w Katowicach, będący podstawą zaopatrzenia w wodę Górnego Śląska, jest największym tego rodzaju przedsiębiorstwem w Polsce, z którego korzysta około 3 mln mieszkańców. W strukturze materiałowej rurociągów magistralnych o łącznej długości ponad 1100 km w zakresie średnic od 400 mm do 1800 mm, 82% stanowi stal, często bez dodatkowego zabezpieczenia od wewnątrz. Ponad 2-krotny spadek zużycia wody przez ludność i przemysł wpłynął w istotny sposób na pogorszenie parametrów hydraulicznych jej transportu. Dla 33% długości tych rurociągów prędkość przepływu wody nie przekracza 0,1 m/s, a dla 47% zawiera się w przedziale 0,1÷0,5 m/s. Czas przetrzymania wody w systemie dystrybucji, łącznie z przepływem przez zbiorniki wyrównawcze, zawiera się od około 3 godz. do ponad 120 godz. W pracy dokonano analizy porównawczej składu fizyczno-chemicznego i bakteriologicznego wody opuszczającej poszczególne zakłady uzdatniania z jakością wody w zbiornikach sieciowych i charakterystycznych punktach sprzedaży, celu uzyskania odpowiedzi na pytanie jaki wpływ na jakość transportowanej wody ma czas jej przebywania w systemie dystrybucji. Stwierdzono sporadyczne przekroczenia dopuszczalnych wskaźników fizyczno-chemicznych wody w niektórych punktach jej sprzedaży z systemu dotyczące głównie barwy, mętności oraz zawartości związków żelaza i manganu. Wykazano, że większość rurociągów o dużych średnicach pracuje jako osadniki bardzo czułe na chwilowy wzrost natężenia przepływu wody, co może być przyczyną katastrofalnego pogorszenia jakości wody wodociągowej.
The group water supply system Górnośląskie Przedsiębiorstwo Wodociągów (GPW), Katowice, is Poland's largest system of that kind. With water-mains of 1100-km length and diameters varying from 400 to 1800 mm, the GPW serves a population of three million inhabitants. The majority of the pipes are made of steel (82%) without any lining. An over two-fold decrease in water consumption (both by the population and the industry) extended considerably the time of water residence in the distribution system (now ranging between approximately 3 h and over 120 h). Physicochemical and bacteriological analyses were carried out to establish how the residence time affects the quality of transported water. The investigations revealed episodes of exceeded permissible values, mostly those of coloured matter concentration, turbidity, as well as iron compounds and manganese content. The majority of pipes with large diameters were found to act as settling tanks sensitive to a temporary rise in flow rate, posing a serious risk of disastrous water quality deterioration.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 3, 3; 29-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stabilności wody wprowadzanej do sieci wodociągowej
Stability Assessment of Water Introduced into the Water Supply Network
Autorzy:
Wolska, M.
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/236953.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
tap water
chemical stability
biostability
water aggressiveness
nutrients
woda z kranu
stabilność chemiczna
sieć wodociągowa
Opis:
Both chemical and biological stability of water was assessed from the three water supply networks using different water sources: surface, infiltration and the mixed (surface and groundwater). The oxidizing agent content, Langelier and Ryznar corrosivity indexes and water aggressiveness index were chosen as criteria for the water chemical stability assessment. Water biostability was determined on the basis of nutrient content: inorganic nitrogen and phosphate forms as well as biodegradable organic carbon (BDOC). It was established that in respect of chemical stability, the waters had some common characteristics such as dissolved oxygen and chlorine oxidizing agent content, conducive to the electrochemical corrosion process, as well as lack of an aggressive carbon dioxide with the concurrent lack of calcium-carbonate equilibrium supporting scale formation. The Ryznar index values were indicative of the corrosive potential of water; the surface water samples belonged to a clearly ‘corrosive’ range. The biological instability was a constant feature of the tested waters and it was the excessive inorganic nitrogen content that was the most conducive to the bacterial regrowth in the water. In either case, disinfectant content was determined to be inadequate with regard to prevention of biological recontamination of water, which was in contrast with its excess in relation to water corrosivity criterion.
Chemiczna i biologiczna stabilność wody została oceniona w trzech sieciach wodociągowych wykorzystujących różne źródła wody: powierzchniowe, infiltracji i mieszane (powierzchniowych i podziemnych).
Źródło:
Ochrona Środowiska; 2015, 37, 4; 51-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies