Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "solids" wg kryterium: Temat


Tytuł:
Applying of water quality indices methods for assessment of 9-Nissan Water Treatment Plant
Autorzy:
Abdul-Hameed, Hayder M.
Powiązania:
https://bibliotekanauki.pl/articles/1844403.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
nitrate
pH
suspended solids
water quality index
water treatment plant
Opis:
In this research different methods for measuring water quality indices were conducted to investigate the performance of the newly designed, constructed and operated 9-Nissan water treatment plant, Iraq. Data gathering and implementation took place throughout winter and summer. Water samples were taken periodically, according to the standard method, the research was carried out by collecting different random samples for eight months (Jun. 2015–Jan. 2016) and measuring (turbidity, total hardness, pH, total dissolved solids, suspended solids, Cl–, Mg2+, Fe2+,NO3–, NH3+) for each sample. Five different approaches and methodologies of calculating the water index were applied. The results revealed that the Water Quality Indices varied from 70.55 to 88.24, when applying Canadian Council of Ministers of the Environment Water Quality Index (CCMEWQI) and British Columbia water quality index (BCWQI) geometric weighted mean respectively. All the results, from the five approaches indicated good water quality, multiple regression analyses were conducted for turbidity, total hardness and suspended solids, they found that these parameters are strongly related to each other and to other parameters.
Źródło:
Journal of Water and Land Development; 2020, 47; 25-29
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of Municipal Wastewater Using Electrocoagulation Process
Autorzy:
Abshishek, H.
Vijayakumar, H.
Mahesh Kumar, C L
Shwetha, Kotagi Girisha
Powiązania:
https://bibliotekanauki.pl/articles/27314889.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
electrocoagulation
municipal sewage
central composite design
CCD
response surface methodology
total suspended solids
TSS
elektrokoagulacja
ścieki komunalne
kompozyty
metodologia powierzchni odpowiedzi
RSM
zawiesiny
Opis:
Treatment of Municipal wastewater by Electrocoagulation (EC) process using punched aluminium and zinc electrodes was studied in a batch EC cell reactor. Response surface methodology (RSM) based on Central Composite Design (CCD) was utilized to optimize the operating parameters for the removal of % Total Suspended Solids (TSS) and % Chemical Oxygen Demand (COD) from Municipal Sewage. Effect of operating parameters such as Electrode Distance (x1), Electrolysis Time (x2) and Voltage (x3) has been optimized for the removal of TSS and COD. The prediction of removal percentage of TSS and COD in various Operational circumstances is done by using Quadratic model. The significance of each operating parameter was computed by Analysis of variance (ANOVA). To achieve the maximum removal of % TSS and % COD, the optimum conditions were Electrode distance(x1)-3 cm, Electrolysis Time (x2)-70.299 minute and Voltage (x3)-6.5V. It was observed that the performance of electrocoagulation process increased up to 61.45% for COD removal, and 73.73% for TSS removal using punched electrode compared to plane electrodes.
Źródło:
Civil and Environmental Engineering Reports; 2023, 33, 4; 1--13
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimizing the Reduction of Total Suspended Solids in Pump Water from Fish Factories Through Electrocoagulation using Response Surface Methodology
Autorzy:
Aguilar-Ascón, Edwar
Neyra-Ascón, Walter
Albrecht-Ruiz, Miguel
Ibarra-Basurto, Alonso
Powiązania:
https://bibliotekanauki.pl/articles/1838313.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
total suspended solids
TSS
electrocoagulation
fish meal
fish pumping water
response surface methodology
optimization
Opis:
This study aims to optimize the removal of total suspended solids (TSS) in pump water from fish flour factories through electrocoagulation technology and to determine the effects of the main operation parameters. Pump water has high conductivity (40.1 mS), due to the presence of dissolved salts and contains high concentration of organic substances (12,360 mg/L of TSS and 520 mg/L of fats). In this study, pump water was treated in an electrocoagulation reactor with aluminum electrodes using Response Surface Methodology with a 3k factorial design based on two factors, current intensity (I) of 8-13 A and treatment time (t) of 20-40 minutes. The percentage of TSS removed from the water was used as the response variable. The results revealed that I and t significantly (p < 0.05) influenced the process. In accordance, the optimal operational parameters for TSS removal were I = 13 A and t = 30 minutes. Using these conditions, TSS removal efficiency of 99.9% was achieved. The sewage sludge generated with these optimal process conditions indicated 19.3% of ash content, 6.2% of salt, 1.7% of aluminum, 0.3% of iron, 0.4% of potassium, 256 ppm of zinc, and 2.1% of phosphorus. Hence, the results of this study affirm that electrocoagulation can be considered as a solution for marine pollution caused by fishing industries.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 269-277
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimizing the Reduction of Total Suspended Solids in Pump Water from Fish Factories Through Electrocoagulation using Response Surface Methodology
Autorzy:
Aguilar-Ascón, Edwar
Neyra-Ascón, Walter
Albrecht-Ruiz, Miguel
Ibarra-Basurto, Alonso
Powiązania:
https://bibliotekanauki.pl/articles/1838335.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
total suspended solids
TSS
electrocoagulation
fish meal
fish pumping water
response surface methodology
optimization
Opis:
This study aims to optimize the removal of total suspended solids (TSS) in pump water from fish flour factories through electrocoagulation technology and to determine the effects of the main operation parameters. Pump water has high conductivity (40.1 mS), due to the presence of dissolved salts and contains high concentration of organic substances (12,360 mg/L of TSS and 520 mg/L of fats). In this study, pump water was treated in an electrocoagulation reactor with aluminum electrodes using Response Surface Methodology with a 3k factorial design based on two factors, current intensity (I) of 8-13 A and treatment time (t) of 20-40 minutes. The percentage of TSS removed from the water was used as the response variable. The results revealed that I and t significantly (p < 0.05) influenced the process. In accordance, the optimal operational parameters for TSS removal were I = 13 A and t = 30 minutes. Using these conditions, TSS removal efficiency of 99.9% was achieved. The sewage sludge generated with these optimal process conditions indicated 19.3% of ash content, 6.2% of salt, 1.7% of aluminum, 0.3% of iron, 0.4% of potassium, 256 ppm of zinc, and 2.1% of phosphorus. Hence, the results of this study affirm that electrocoagulation can be considered as a solution for marine pollution caused by fishing industries.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 269-277
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reverse osmosis as one-step wastewater treatment: a case study on groundwater pollution
Autorzy:
Ali, W.
Rehman, W. U.
Younas, M.
Ahmad, M. I.
Gul, S.
Powiązania:
https://bibliotekanauki.pl/articles/779416.pdf
Data publikacji:
2015
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
reverse osmosis (RO)
membrane separation
Total Dissolved Solids (TDS)
Total Coliform
E. Coli
Opis:
The present case study is focused on performance evaluation of a Reverse Osmosis (RO) membrane based pilot plant to treat the ground/surface drinking water sources polluted by flood, rivers and/or canals. The RO plant was designed, fabricated and then operated with polluted water. Two feed water samples having a TDS of 2.000 mg · L−1 and 10.000 mg · L−1 respectively, were taken and analyzed for physical, chemical and microbiological contaminants. The RO plant was run once through over a span of 100 hrs at an operating pressure of 15 bar. TDS rejections were found to be more than 94% while permeate flux was measured to be 25.82 L · m−2 · hr−1 to 40.55 L · m−2 · hr−1. Results show that RO plant has a potential to remove physical, chemical and microbiological contaminants like Total Coliform and E. Coli in one step.
Źródło:
Polish Journal of Chemical Technology; 2015, 17, 4; 42-48
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury, intensywności mieszania oraz napowietrzania na efektywność procesu bioługowania metali z wybranych odpadów przemysłowych
Impact of the temperature, mixing intensity and aeration on the effectiveness of metal bioleaching from selected industrial wastes
Autorzy:
Andrzejewska-Morzuch, D
Karwowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/1819333.pdf
Data publikacji:
2012
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
acidophilic bacteria
microorganisms
viability
ecology
solids
iron
sewage sludge
Opis:
In the research work the influence of temperature, mixing intensity and aeration on heavy metals release from two types of industrial heavy metal containing wastes - combustion ash and galvanic waste - was analyzed. The bioleaching process was carried out using the culture based on the activated sludge as a source of active, sulphur-oxidizing microflora. The presence of Acidithiobacillus thiooxidans bacteria was proved using PCR technique. The culture was initially adapted to the growth in presence of 1% sulphur, up to the moment it achieved pH 1-2. The experiment was carried out in four variants, with different process parameters: temperature 22 degrees C, mixing 125 rpm, without aeration; temperature 22 degrees C, mixing 50 rpm, without aeration; temperature 37 degrees C, mixing 125 rpm, without aeration; temperature 22 degrees C, mixed and aerated with compressed air. After 14 days the amount of heavy metals released from the wastes was determined using ASA method to evaluate the process effectiveness in different experimental conditions. Mean value, standard deviation and variation coefficient was calculated. The effectiveness of heavy metals removal from the ash was significantly higher than the galvanic sludge bioleaching, in which only cadmium and chromium was effectively released (with the average effectiveness of 14.8-47.8% of Cd and 12.5-90,6% of Cr, depending on the experimental variant). In case of the combustion ash, the average removal efficiencies were: 1.1-22% of Zn, 04-12.3% of Cu, 2.8-19.7% of Pb, 3.4-6.7% of Cd, 2.8-52.2% of Ni and 43.8-87.4% of Cr, depending on process parameters. The increase of temperature from 22 to 37 degrees C resulted in the increased effectiveness of almost all metals from both tested wastes. Cadmium was the only metal that was leached better in 22 degrees C. In case of galvanic waste, Cd was released more effectively in cultures with mixing intensity of 125 rpm, and in the culture without aeration, while the aeration was favorable to Cr release. For the ash the additional aeration increased the removal of Cu, Cd, Ni and Cr. Copper, lead, nickel and chromium were released effectively using the 50 rpm mixing but zinc - in 125 rpm. The influence of the mixing intensity on cadmium bioleaching from the ash was not observed. The research indicated that the influence of tested parameters depended on the type of the waste as well as the kind of the metal. It is probably influenced by the other factors like the form of the metal in the waste, that should be a subject of further investigations.
Źródło:
Rocznik Ochrona Środowiska; 2012, Tom 14; 623-631
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zawartość zawiesin i metali ciężkich w wybranych falach ścieków deszczowych w zlewni miejskiej
Suspended solids and heavy metals content of selected rainwater waves in an urban catchment area: A case study
Autorzy:
Bąk, Ł.
Górski, J.
Górska, K.
Szeląg, B.
Powiązania:
https://bibliotekanauki.pl/articles/236836.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
zlewnia zurbanizowana
ścieki deszczowe
zawiesiny
metale ciężkie
urbanized catchment area
rainwater
suspended solids
heavy metals
Opis:
Przedstawiono wyniki badań zawartości jonów wybranych metali ciężkich (Ni, Cu, Cr, Zn, Pb, Cd), zawiesin ogólnych oraz chlorków w pięciu falach (3 deszczowych, 2 roztopowych) odprowadzanych z obszaru zlewni silnie zurbanizowanej (Kielce, województwo świętokrzyskie). Badania przeprowadzono na kolektorze deszczowym (Si9) odbierającym wody deszczowe i roztopowe z części miasta o powierzchni 62 ha, położonej w lewostronnej części zlewni rzeki Silnicy. W zlewni wydzielono 6 rodzajów powierzchni: dachy (14,3%), chodniki (8,4%), jezdnie (17,7%), parkingi (11,2%), zieleń (47,2%) i boiska szkolne (1,3%). Zaobserwowane w czasie od maja 2009 r. do czerwca 2010 r. wezbrania charakteryzowały dużą różnorodnością. Wartości strumienia objętości ścieków deszczowych podczas wezbrań wahały się od 45 dm3/s do 380 dm3/s, a czas trwania wezbrania zawierał się w przedziale od 100 min do 500 min. Z przeprowadzonych badań wynika, że największe średnie zawartości ołowiu i cynku wynosiły odpowiednio 0,304÷0,992 gPb/m3 i 0,158÷0,473 gZn/m3. Średnia zawartość jonów pozostałych metali była znacznie mniejsza i nie przekraczała 0,195 g/m3. Zawartość zawiesin ogólnych i chlorków w spływach roztopowych była kilkakrotnie większa niż w spływach deszczowych. W ściekach deszczowych odprowadzanych z terenu badanej zlewni miejskiej stwierdzono silną zależność między parami jonów metali Cu-Cr, Cu-Zn, Cd-Pb oraz Cd-Zn. Nie stwierdzono natomiast statystycznie istotnej zależności korelacyjnej między zawiesinami ogólnymi a jonami badanych metali.
Analyses were carried out to determine the concentrations of six heavy metals chosen (Ni, Cu, Cr, Zn, Pb, Cd), total suspended solids and chlorides in five waves (three of rain runoff and two of melting runoff) discharged from a highly urbanized catchment area (Kielce, district Wojewodztwo Swietokrzyskie). The study involved a rain collector (Si9) receiving rainwater and melting runoff from some part of the city, which covered an area of 62 ha and was located on the left-hand side of the Silnica River drainage basin. Within this basin, six types of surface runoff were separated: roofs (14.3%), sidewalks (8.4%), roadways (17.7%), parks (11.2%), green belts (47.2%) and school grounds (1.3%). The floods observed from May 2009 to June 2010 were characterized by great diversity. Flow values for the culmination of these waves ranged from 45 to 380 dm3/s, and the duration of flooding varied between 100 min and 500 min. The results of the study show that the highest average concentrations of lead and zinc fell within the range of 0.304-0.992 gPb/m3 and 0.158-0.473 gZn/m3, respectively. The average content of the other metal ions was much lower and did not exceed 0.195 g/m3. The content of total suspended solids and that of chlorides in the melting runoff were several times as high as in the rain runoff. In the rainwater discharged from the investigated highly urbanized catchment area a strong correlation was observed between the following pairs of metal ions: Cu-Cr, Cu-Zn, Cd-Pb and Cd-Zn. No statistically significant correlative relation was found to occur between total sus-pended solids and the ions of the metals examined.
Źródło:
Ochrona Środowiska; 2012, 34, 2; 49-52
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cell walls polysaccharides of rose hips
Autorzy:
Balcerak, Bogumił
Milala, Joanna
Kosmala, Monika
Matysiak, Bożena
Klewicka, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/410419.pdf
Data publikacji:
2019
Wydawca:
Politechnika Łódzka. Wydawnictwo Politechniki Łódzkiej
Tematy:
rose hips
AIS
alcohol insoluble solids
polysaccharides composition
galacturonic acid
sequential pectins extraction
plant cell wall
gas chromatography
owoc róży
substancje nierozpuszczalne w alkoholu
budowa polisacharydów
kwas galakturonowy
sekwencyjna ekstrakcja pektyn
ściana komórkowa roślin
chromatografia gazowa
Opis:
The content of alcohol insoluble solids (AIS), polysaccharide composition of cell walls and uronic acids content calculated as galacturonic acid in rose hips (Rosa villosa (Rosa pomifera Herrm) ‘Karpatia', Rosa canina L., Rosa rugosa Thunb.). Rose hips were extracted by means of pectin sequential extraction. Rose achenes contained more alcohol insoluble solids than flesh. The main saccharide building cell walls of rose fruit was glucose from cellulose. The achenes were rich in xylose and the flesh was rich in arabinose. The content of galacturonic acid in flesh was 2 to 3 times higher than in the case of achenes. The largest polysaccharide fraction both in whole fruit and achenes was Concentrated Alkali-Soluble Polysaccharides fraction, while in flesh it was Water Soluble Pectins fraction. Chelating Agent Soluble Pectins fraction was the smallest in the flesh, achenes and the whole hypanthium. Differences in the polysaccharide composition, the content of AIS and galacturonic acid were found, depending on the species of rose hips. In addition, differences in composition were found in the case of wild growing and controlled cultivation hips. Rose hips achenes contain more total dietary fiber than the flesh, but the flesh contains more pectin fraction (soluble dietary fiber) while the achenes contain more cellulose (insoluble dietary fiber).
Źródło:
Biotechnology and Food Science; 2019, 83, 2; 141-156
2084-0136
2299-6818
Pojawia się w:
Biotechnology and Food Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola zawiesin w transporcie metali ciężkich w wodach powierzchniowych na przykładzie Kłodnicy
The role of suspended solids in the transport of heavy metals in surface water, exemplified by the Klodnica River (Upper Silesia)
Autorzy:
Barbusiński, K.
Nocoń, W.
Nocoń, K.
Kernert, J.
Powiązania:
https://bibliotekanauki.pl/articles/236838.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda rzeczna
zawiesiny
osady denne
metale ciężkie
transport zanieczyszczeń
river water
suspended solids
bottom sediments
heavy metals
pollution transport
Opis:
Przedstawiono wyniki badań zawartości jonów wybranych metali ciężkich (Zn, Pb, Cd, Cr, Cu, Ni, Mn i Fe) w zawiesinach zawartych w wodzie powierzchniowej, na przykładzie Kłodnicy (Górny Śląsk). Próbki wody z zawiesinami pobrano w 8 punktach zlokalizowanych wzdłuż całej długości rzeki. Uzyskane wyniki badań interpretowano zgodnie z niemiecką klasyfikacją LAWA. Stwierdzono korelację pomiędzy zawartością jonów badanych metali ciężkich a zawartością żelaza w zawiesinach. Stwierdzono również, że zawartość metali w zawiesinach obecnych w wodzie z Kłodnicy była mniejsza niż w zawiesinach w Odrze i jej dopływach. Wykazano trównież, że zawartość jonów metali ciężkich w zawiesinach była kilkakrotnie większa niż w osadach dennych, co świadczyło o istotnej roli zawiesin w procesie przemieszczania się zanieczyszczeń wraz z biegiem rzeki. Duże zmiany zawartości jonów metali ciężkich w zawiesinach, obserwowane zarówno w trakcie prowadzenia badań, jak i wynikające z danych literaturowych, wskazują na celowość prowadzenia badań nad dynamiką tych zmian.
Concentrations were measured of eight heavy metals (Zn, Pb, Cd, Cr, Cu, Ni, Mn, Fe) found in the suspended solids of surface water. The Klodnica River was chosen as an example to demonstrate the role of suspended solids in heavy metal transport. Water samples containing suspended solids were collected at eight points located along the entire length of the river. The results were interpreted using the German classification LAWA. A correlation was found to occur between the heavy metal ion content and the iron content of the suspended solids. Comparative analysis has demonstrated that the heavy metal content of suspended solids was lower in the Klodnica than in the Odra River and its tributaries. Analysis of the results has also revealed that the heavy metal ion content of suspended solids was several times that of the bottom sediments. This substantiates the significant role of suspended solids in the transport of pollutants down the river. Considerable changes in the heavy metal ion content of suspended solids (not only observed during this study but also reported in the literature) corroborate the need of investigating the dynamics of these changes.
Źródło:
Ochrona Środowiska; 2012, 34, 2; 33-38
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Handling and transportation properties of rapeseed biomass as affected by particle size
Autorzy:
Bojanowska, Milena
Powiązania:
https://bibliotekanauki.pl/articles/29521042.pdf
Data publikacji:
2023
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
rapeseed meal
rapeseed cake
canola
biomass
agricultural commodities
bulk storage
flowability
logistics vulnerability
particle size
angle of repose
porosity
bulk density
agricultural bulk solids
Opis:
Rapeseed by-products of seeds de-oiling, particularly expellers and post-extracted meal, are currently considered an important biomass that can be used as an alternative energy source, either in raw form or after conversion to biochar. Rapeseed biomass represents a difficult-to-handle cargo, mainly due to its sensitivity to mechanical, climatic, and biological impacts, as well as its dusty nature. This study aims to determine the physical properties of rapeseed meals and their fractions. Morphological and chemical features of six particle sets are investigated in order to explain the variation in their physical properties having importance in handling and transportation processes. The true density of fractions increases when the particle size decreases due to the diminishing quantitative share of seed coats. No correlation is observed between true and bulk densities, as the particle shape, surface sculpture, and adhesion affect the mutual particle arrangements. Along with a decrease in the particle size from 0.4 mm, a rapid decrease in the flowability is observed. The tendency of the finest dust (d < 0.075 mm) to form agglomerated complexes causes its lower bulk density, higher porosity, and higher angles of repose in comparison to coarse dust (0.075–0.4 mm). It is concluded that a relatively low tendency to free flowing of natural RSM is mainly caused by its wide-ranging particle size distribution and their geometry differentiation, which facilitate mutual particle interlockings. The known cases of blockages of silos, bins, hoppers, and transfer chutes may be mainly caused by the powder fractions (< 0.2 mm), with a much lower flowability than other particles.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2023, 74 (146); 5-15
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza budowy przestrzennej zawiesin występujących w wodach naturalnych
Analyzing the spatial structure of suspended solids in natural waters
Autorzy:
Burszta-Adamiak, E.
Łomotowski, J.
Kęszycka, M.
Powiązania:
https://bibliotekanauki.pl/articles/237546.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody naturalne
zawiesiny
wymiar fraktalny
granulometr laserowy
natural waters
suspended solids
fractal dimension
laser granulometer
Opis:
Dyfraktometria laserowa jest nowoczesną metodą, którą można wykorzystać do wyznaczenia wymiaru fraktalnego zawiesin znajdujących się w wodach naturalnych. Do najważniejszych zalet tej metody należy szybkość wykonania pomiaru oraz duża powtarzalność wyników. Równolegle z badaniami składu granulometrycznego możliwa jest identyfikacja budowy przestrzennej cząstek tworzących zawiesiny. W pracy przedstawiono wyniki badań składu granulometrycznego wód opadowych, roztopionego ściegu, spływów z dachów oraz wody powierzchniowej z Odry. Wykazano, że objętościowy wymiar fraktalny (D3) zawiesin w tych wodach najczęściej przyjmował wartości bliskie 2,0. Świadczy to, że cząstki tworzące zawiesiny mają budowę przestrzenną, zbliżoną do struktur liniowych, z dużą ilością otwartych przestrzeni. Wykazano celowość prowadzenia badań składu granulometrycznego zawiesin w monitoringu wód naturalnych oraz podczas kontroli przebiegu procesów oczyszczania wody.
The uses where laser diffractometry is applicable include measurements of the fractal dimensions of the suspended solids that occur in natural waters. Among the major benefits offered by this advanced method are the availability of quick measuring procedures and a high repeatability of the results obtained. Granulometric studies performed using a laser diffractometer enable simultaneous identification of the spatial structure of suspended solids particles. The authors have characterized the granulometric composition of precipitation water, melted snow, roof runoff and surface water runoff from the river Odra. They have demonstrated that the volumetric fractal dimension (D3) of the suspended solids which were present in these waters took values close to 2.0 in the majority of instances. This is an indication that the particles of which the suspended solids are built display a spatial structure similar to the linear one, with a large amount of available space. The need has been emphasized for granulometric examinations of suspended solids within the framework of natural water monitoring, as well as during water treatment process control.
Źródło:
Ochrona Środowiska; 2009, 31, 3; 65-68
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applications of implicit constitutive theory for describing the elastic response of rocks and concrete
Autorzy:
Bustamante, R.
Rajagopal, K. R.
Powiązania:
https://bibliotekanauki.pl/articles/38695703.pdf
Data publikacji:
2022
Wydawca:
Instytut Podstawowych Problemów Techniki PAN
Tematy:
nonlinear elasticity
small strain
isotropic solids
Opis:
An implicit constitutive relation is proposed for elastic bodies, when the gradient of the displacement is assumed to be very small, and as a result the strains are small. The resulting constitutive relation is a non-linear relationship between the linearized strain and the stress. The model is used to fit data for rock and concrete. Some boundary value problems are studied within the context of homogeneous deformations, and also a problem with inhomogeneous deformations is analyzed, namely the inflation of a circular annulus. The predictions of this new implicit constitutive relation are compared with the predictions of the constitutive equations for linearized elastic bodies.
Źródło:
Archives of Mechanics; 2022, 74, 6; 513-547
0373-2029
Pojawia się w:
Archives of Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pracy oczyszczalni ścieków w Kołaczycach
Operational efficiency of wastewater treatment plant in Kolaczyce
Autorzy:
Chmielowski, K.
Młyńska, A.
Młyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/400312.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
oczyszczalnia ścieków
BZT5
ChZTCr
zawiesina ogólna
wastewater treatment plant
BOD5
CODCr
total suspended solids
Opis:
W artykule dokonano analizy efektywności pracy oczyszczalni ścieków w Kołaczycach na podstawie wyników badań fizykochemicznych ścieków surowych oraz ścieków oczyszczonych w latach 2010 – 2014. Przeanalizowano zmiany wartości trzech wskaźników zanieczyszczeń – BZT5, ChZTCr i zawiesiny ogólnej. Wyniki badań wskazują na to, iż oczyszczalnia funkcjonuje w sposób prawidłowy. Średnia wartość BZT5 w ściekach oczyszczonych wyniosła 10,9 mg O2 dm-3, ChZTCr – 71,0 mg O2 dm-3, zawiesiny ogólnej – 15,0 mgdm-3, a zatem wielkości te były mniejsze od dopuszczalnych wartości w ściekach odprowadzanych do odbiornika, które reguluje Rozporządzenie Ministra Środowiska z 2014 roku. O zadowalającej efektywności pracy obiektu świadczy również wysoka procentowa średnia redukcja każdego ze wskaźników zanieczyszczeń (dla BZT5 – 97,8%, dla ChZTCr – 93,7%, dla zawiesiny ogólnej – 97,6%), a także wartości współczynników niezawodności oczyszczalni (WNBZT5= 0,44, WNChZTCr= 0,57, WNzaw.og.= 0,43).
In the article the analysis of operational efficiency Wastewater Treatment Plant in Kolaczyce was performed based on the physico-chemical research results of raw sewage and treated sewage between 2010 and 2014. The analysis of values changing of three pollutants indicators – BOD5, CODCr and total suspended solids was performed. Research results indicate that treatment plant works properly. Average value of BOD5 in treated sewage was 10.9 mg O2 dm-3, CODCr – 71.0 mg O2 dm-3, total suspended solids – 15.0 mg dm-3 so these values were lower than permissible pollutants content in sewage discharged to the collector which is determined by the Polish Ministry of Environmental Regulation of 2014. On satisfactory operational efficiency treatment plant indicates also high percentage reduction of each pollutants indicators (for BOD5 – 97.8%, for ChZTCr – 93.7%, for total suspended solids – 97.6%) and treatment plant reliability factors (WNBZT5= 0.44, WNChZTCr= 0.57, WNzaw.og.= 0.43).
Źródło:
Inżynieria Ekologiczna; 2015, 45; 44-50
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in the Quality of Domestic Sewage Caused by the Reduction of Water Consumption in Households
Autorzy:
Chudzicki, Jarosław
Umiejewska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/123072.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water consumption
saving water
municipal wastewater
total suspended solids
Opis:
Since the 1990s, there have been trends in Central and Eastern European countries to reduce water consumption. This phenomenon is closely related to the political, social and economic changes in these countries and the introduction of economic instruments in water management. The article presents the changes in water consumption in households in the years 1950–2019 depending on the degree of equipping buildings with sanitary facilities, and the structure of water consumption for particular purposes. For the same period, the quality of sewage generated in households is presented on the basis of bibliography. The content of total suspended solids was the main analysed parameter. The last part of the article presents the quality of wastewater discharged to fourteen Polish wastewater treatment plants. The majority of the analysed plants show an increase in the concentration of total suspended solids in the domestic sewage discharged to them. This phenomenon may be influenced by the decreasing water consumption in households.
Źródło:
Journal of Ecological Engineering; 2020, 21, 3; 41-50
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interaction of elastic waves with a fluid-saturated porous solid boundary
Oddziaływanie fal sprężystych z brzegiem nasyconego płynem ośrodka porowatego
Autorzy:
Cieszko, M.
Kubik, J.
Powiązania:
https://bibliotekanauki.pl/articles/281300.pdf
Data publikacji:
1998
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
saturated porous solids
wave reflection
Opis:
The problem of energy reflection and transmission of an oblique incident plane harmonic wave at the surface of an elastic porous solid halfspace immersed in fluid is considered. The case of pure elastic behaviour of the system with incompressible material of skelton is analysed. Considerations are based on the two parametric theory of fluid-saturated porous solid in which the isotropic pore structure is described by the volume porosity and the parameter characterising tortuosity of pores. The influence of mechanical properties of both the physical constituents and angle of wave incidence on the energy reflection and transmission coefficients is analysed. Two general cases of the wave interaction are investigated: waves incident from the bulk fluid on the surface of porous halfspace, and waves (fast, slow and shear) incident from a fluid-saturated porous solid. Calculations have been made for the system composed of porous fused glass bead solid filled with water in one case and with ethyl alcohol in the other case and diagrams of the results have been shown.
W pracy rozważono zagadnienie odbicia i przenikania fal harmonicznych ukośnie padających na powierzchnię porowatej półprzestrzeni zanurzonej w płynie. Przeanalizowano czysto sprężyste zachowanie się układu o nieściśliwym materiale szkieletu. Do rozważań wykorzystano dwuparametrową teorię deformowalnego ośrodka porowatego nasyconego płynem, w której struktura porów szkieletu charakteryzowana jest przez porowatość objętościową i krętość porów. Przeanalizowano wpływ mechanicznych własności składników fizycznych oraz kąt padania fali na energetyczne współczynniki odbicia i przenikania fal. Rozważono dwa przypadki: gdy fala pada na powierzchnię porowatej półprzestrzeni od strony samego płynu oraz przypadek, gdy fale (szybka, wolna i poprzeczna) padają od strony nasyconego płynem porowatego ośrodka. Obliczenia przeprowadzono dla ośrodka porowatego ze spiekanych kulek szklanych wypełnionych wodą w jednym przypadku oraz alkoholem etylowym w drugim przypadku.
Źródło:
Journal of Theoretical and Applied Mechanics; 1998, 3; 561-580
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies