Tytuł:
Comparison of transformer modeling on riser pole arresters behavior during switching transients
Autorzy:
Abbaszadeh, A.
Abedi, M.
Doustmohammadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/140474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arresters
ATP software
ferroresonance
transformer
power system transients
Opis:
Arresters are widely used in power systems to protect other equipment against overvoltages. However, in some conditions, they can’t operate successfully. One of the disturbances leading to the failure of the riser pole arresters is the ferroresonance overvoltages. In this paper, at first the influence of different transformer simulation models of ATP software on the occurrence of ferroresonance is studied and then the effect of ferroresonance on the riser pole arrester has been scrutinized through the thermal and electrical performance of the arrester in an underground distribution system. The results show that the arrester temperature rises due to energy dissipation in a ferroresonance circumstance, which indeed may result into the explosion of the arrester. Also, applying different models of the transformer in the ATP software and comparing the results, it is shown that the available models do not show the same effect on the arrester.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 717-730
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of delta/polygon-connected transformer-based 36-pulse ac-dc converter for power quality improvement
Autorzy:
Abdollahi, R.
Powiązania:
https://bibliotekanauki.pl/articles/140490.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
jakość energii
prostownik 36-pulsowy
bezpośredni moment obrotowy silnika indukcyjnego sterowanego napędem
AC-DC converter
delta/polygon transformer
power quality
direct torque controlled induction motor drive (DTCIMD)
Opis:
Design of a delta/polygon-connected autotransformer based 36-pulse ac-dc converter is presented in this paper. The 36-pulse topology is obtained via two paralleled eighteen-pulse ac-dc converters each of them consisting of a nine-phase (nine-leg) diode bridge rectifier. For independent operation of paralleled diode-bridge rectifiers, two interphase transformers (IPT) is designed and implemented. A transformer is designed to supply the rectifier. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. The proposed structure has been implemented and simulated using Matlab/Simulink software under different load conditions. Simulation results confirmed the significant improvement of the power quality indices (consistent with the IEEE-519 standard requirements) at the point of common coupling. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 4% for the proposed topology at variable loads.
Źródło:
Archives of Electrical Engineering; 2012, 61, 2; 277-292
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power Electronics Building Blocks for implementing Smart MV/LV Distribution Transformers for Smart Grid
Energoelektroniczne moduły funkcjonalne dla realizacji inteligentnych transformatorów dystrybucyjnych SN/nn dla sieci Smart Grid
Autorzy:
Adamowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/396968.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
smart grid
distribution transformer
power electronics
inteligentne sieci energetyczne
transformator dystrybucyjny
energoelektronika
Opis:
With an observed increase in the involvement of active consumers in activities aimed at improving energy efficiency and increasing interest in producing energy from renewable sources, there is a need for the development of new technologies enabling the distribution network operators to offer new services and functionalities. Smart MV/LV distribution transformers are characterized by a compact three-stage design, including an input stage in the form of a controlled power electronic AC-DC converter on the MV side, intermediate stage in the form of a DC-DC converter with isolation implemented at high frequency and an output stage in the form of controlled power electronic DC-AC converter on the LV side. Topologies and functionalities of basic subsystems of smart distribution transformer are discussed in the paper using the Power Electronics Building Blocks concept. The recent results of investigations carried out at Gdańsk University of Technology are also presented.
Przy coraz większym zaangażowaniu aktywnych odbiorców w działania mające na celu poprawę efektywności wykorzystania energii oraz wzroście zainteresowania wytwarzaniem energii z odnawialnych źródeł konieczne staje się opracowanie rozwiązań technologicznych, które umożliwią operatorom sieci dystrybucyjnych rozwój nowych usług i funkcjonalności. W odróżnieniu od konwencjonalnych transformatorów, inteligentne transformatory dystrybucyjne, będące w fazie opracowań, wykorzystują w swej budowie szybkie przyrządy półprzewodnikowe dużej mocy i obwody magnetyczne wysokiej częstotliwości, zapewniając sterowanie dwukierunkowym przepływem energii oraz płynną regulację parametrów napięcia sieci. Z założenia inteligentne transformatory dystrybucyjne charakteryzują się budową modułową. W artykule autor omówił podstawowe energoelektroniczne moduły funkcjonalne, z których realizowane są inteligentne transformatory dystrybucyjne, oraz przedstawił wyniki badań prowadzonych na Politechnice Gdańskiej nad budową modelu inteligentnego transformatora.
Źródło:
Acta Energetica; 2014, 4; 6-19
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smart MV/LV distribution transformer for Smart Grid with active prosumer participation
Inteligentny transformator dystrybucyjny SN/nn dla sieci Smart Grid o aktywnym udziale prosumentów
Autorzy:
Adamowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/396826.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
smart grid
distribution transformer
power elecronics
inteligentne sieci energetyczne
transformator dystrybucyjny
energoelektonika
Opis:
With the development of distribution networks and their gradual transformation into intelligent Smart Grid type networks the relevance and share of controlled power converter systems used as interfaces between energy sources and the grid, and between grid and the recipients, will grow. This paper elaborates on the concept of replacing conventional 50 Hz distribution transformers with intelligent distribution transformers. A solution of a three-stage smart distribution transformer of modular design is poposed, oriented to connecting prosumers as active recipients of electricity with enhanced reguirements, and owners of small renewable energy systems (RES). Two active stages: AC-DC on the MV side and DC-AC on the LV side provide the ability to comensate reactive power and shape voltage parameters. The simulation results presented here confirm that the smart transformer's intermediate stage, through the use of isolated DC-DC converters with high-speed semiconductor devices, provides the ability to quickly adjust the power flow between the primary and secondary sides.
Wraz z rozwojem sieci dystrybucyjnych i ich stopniowym przekształcaniem w inteligentne sieci typu Smart Grid będzie rosło znaczenie i udział sterowanych układów przekształtnikowych mocy stosowanych jako interfejsy pomiędzy źródłami energii a siecią oraz pomiędzy siecią a odbiorcami. W artykule rozwinięto koncepcję wymiany konwencjonalnych transformatorów dystrybucyjnych 50 Hz na inteligentrne transformatory dystrybucyjne. Zaproponowano rozwiązanie trójstopniowego inteligentnego transformatora dystrybucyjnego o budowie modułowej, zorientowanego na przyłączanie prosumentów jako aktywnych odbiorców energii o podwyższonych wymaganiach oraz właścicieli małych układów odnawialnych źródeł energii (OZE). Dwa stopnie aktywne: AC-DC po stronie SN oraz DC-AC po stronie nn zapewniają możliwość kompensacji mocy biernej i kształtowania parametrów napięcia. Przedstawione wyniki symulacji potwierdzają, że stopień pośredni transformatora inteligentnego, dzięki zastosowaniu izolowanych przetwornic DC-DC z szybkimi przyrządami półprzewodnikowymi, zapewnia możliwość szybkiej regulacji przepływu mocy pomiędzy stroną pierwotną i wtórną.
Źródło:
Acta Energetica; 2012, 3; 4-14
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania oddziaływania akustycznego stacji elektroenergetycznej na środowisko
Research acoustic impact on the environment of the electric power station
Autorzy:
Augustyn, A.
Słaboń, E.
Ślusarek, A.
Powiązania:
https://bibliotekanauki.pl/articles/199185.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
oddziaływanie akustyczne
autotransformator
stacja elektroenergetyczna
ochrona środowiska
acoustic impact
auto-transformer
electric power station
environmental protection
Opis:
W publikacji przedstawiono badania oddziaływania akustycznego stacji elektroenergetycznej na środowisko terenów chronionych oraz koncepcję ograniczania ponadnormatywnej emisji dźwięku. Przedstawiono metodykę rozwiązania problemu emisji dźwięku autotransformatorów do środowiska, obejmującą: pomiary emisji dźwięku, opracowanie numerycznych modeli terenu oraz pokrycia terenu w rejonie autotransformatorów. Określono wpływ głównych źródeł dźwięku na rozkład pola akustycznego na terenach chronionych akustycznie oraz przedstawiono koncepcję zabezpieczeń przeciwhałasowych.
Research of acoustic study of electric power station on the environment for the protected area and the concept of reducing excessive sound emission, are presented. The methodology of solving the problem of auto-transformers sound emission to the environment, including: acoustic measurement, develop digital terrain model and land cover in the area of auto-transformers. The influence of the main sound sources on the distribution of the sound field acoustically protected areas and introduced the concept of protection.
Źródło:
Maszyny Górnicze; 2015, 33, 2; 25-29
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of electric energy quality on fire safety of transformers
Badanie wpływu jakości energii elektrycznej na bezpieczeństwo pożarowe transformatorów energetycznych
Autorzy:
Banasiak, Rafał
Ptak, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/24202671.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
power quality
transformer
fire safety
jakość energii elektrycznej
transformator
bezpieczeństwo pożarowe
Opis:
The use of non-linear devices causes unfavourable changes in the operation of the power system. First of all, they are a source of higher harmonics in network waveforms, which tend to increase the eddy currents. Their effect consists in raising the temperature of transformer cores. This, in turn, translates into their failure rate and fire safety, including reducing the actual value of rated power. The article describes the results of experimental studies carried out on a large scale. An analysis was performed of the quality of electric power depending on the type of network load. The results have shown that the increase in the use of non-linear receivers such as LED lighting, electronic chargers, inverters, etc. may have a tangible impact on the fire hazard of distribution transformers. Examples of calculations have been presented, which prove the necessity of taking into account the influence of higher harmonics on the reduction of the real rated power of power transformers.
Użytkowanie urządzeń o charakterze nieliniowym wprowadza niekorzystne zmiany w funkcjonowaniu systemu elektroenergetycznego. Przede wszystkim są one źródłem wyższych harmonicznych w przebiegach sieciowych, co wpływa na zwiększenie prądów wirowych. Ich oddziaływanie sprowadza się do podnoszenia temperatury rdzeni transformatorów. To z kolei przekłada się na ich awaryjność i bezpieczeństwo pożarowe, w tym na obniżenie rzeczywistej wartości mocy znamionowej. Artykuł opisuje wyniki badań doświadczalnych przeprowadzonych w dużej skali. Analizie poddano jakość energii elektrycznej w zależności od rodzaju obciążenia sieci. Wyniki pozwalają stwierdzić, że wzrost wykorzystania nieliniowych odbiorników takich jak: oświetlenie LED, ładowarki elektroniczne, przetwornice częstotliwości itp. może realnie wpływać na zagrożenie pożarem transformatorów rozdzielczych. Przedstawiono przykładowe obliczenia, które dowodzą konieczności uwzględnienia wpływu wyższych harmonicznych na obniżenie rzeczywistej mocy znamionowej transformatorów energetycznych.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2022, 84; 7--30
0239-5223
2720-0779
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of power losses in a high-frequency planar transformer using a thermal camera
Autorzy:
Barlik, R.
Nowak, M.
Grzejszczak, P.
Zdanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/140759.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power losses estimation
thermal camera
thermal calibration
planar transformer
Dowell’s and Steinmetz’s equations
Opis:
This paper presents the implementation of a thermal camera for the quantitative estimation of power losses in a high frequency planar transformer (100 kHz/ 5600 VA). The methodology is based on the observation of the transient temperature rise and determination of the power losses by means of curves representing the derivative of temperature as a function of power losses dissipated in the transformer. First, the thermal calibration characteristics had to be obtained from a simple experiment, where power losses are generated by DC current in the ferrite core and windings. Next, experimental investigations focused on the determination of the transformer power losses for a short circuit and no load, with a resistive load and with the rectifier as a load were carried out. Finally, to verify the obtained results, analytical calculations based on Dowell’s and modified Steinmetz’s equations were additionally made, which showed a good convergence. The proposed method is easy to implement and can be used as an alternative to the calorimetric method which is time-consuming and requires a complicated measurement setup.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 613-627
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza działania zabezpieczenia podimpedancyjnego dwukadziowego symetrycznego przesuwnika fazowego
Analysis of protection operation under impedance double tank symmetric phase shifting transformer
Autorzy:
Bednarczyk, T.
Halinka, A.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/267229.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
automatyka zabezpieczeniowa
transformator
zakłócenia
Phase Shifting Transformer
power system protection
power transformer
disturbances
Opis:
Zabezpieczenie wykorzystujące kryterium podimpedancyjne stanowi jedno z podstawowych zabezpieczeń jednostek transformatorowych najwyższych napięć (w tym przesuwników fazowych). Zabezpieczenie podimpedancyjne identyfikuje stan pracy chronionego przesuwnika fazowego, sprawdzając położenie końca wektora impedancji wyznaczanej w zabezpieczeniu względem stref pomiarowych zabezpieczenia. Podczas zwarć w obrębie fragmentu sieci objętego ochroną przez zabezpieczenie, koniec wektora impedancji powinien „wchodzić” do stref pomiarowych zabezpieczenia. Wówczas następuje zadziałanie zabezpieczenia i ewentualne wyłączenie przesuwnika fazowego. W artykule zamieszczono wyniki przeprowadzonych badań symulacyjnych warunków działania zabezpieczenia podimpedancyjnego dla dwukadziowego symetrycznego przesuwnika fazowego. W symulacjach uwzględniono szeroki zakres zmian impedancji przesuwnika fazowego, zwarcia wewnętrzne oraz zewnętrzne. Wyniki badań symulacyjnych pozwalają na weryfikację poprawności działania zabezpieczenia podimpedancyjnego przesuwnika fazowego.
Relay protection using criterion under impedance is one of the basic security units high voltage transformer (including phase shifters - PST, ang. Phase Shifting Transformer). Protection under impedance identifies the operating status of the protected PST, checking the position of the end vector impedance to be fixed in terms of securing zones measuring security. While short-circuits within the network portion of the end vector impedance should "enter" zones measuring security. Then followed by a safety device and possible exclusion PST. The article contains the results of the simulation tests of operating conditions for security under impedance doubletransformer tank dwukadziowego symmetric phase shifter. The simulations take into account a wide range of impedance changes PST, short circuit, internal and external. The results of simulation studies allow for verification of correct operation of security under impedance PST.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 71-74
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power plant transformer explosion and fire
Autorzy:
Berg, H.-P.
Fritze, N.
Powiązania:
https://bibliotekanauki.pl/articles/2069665.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
transformer
power plants
explosion
fire
simulation
failure
reliability
risk management
Opis:
The transformer is the key equipment for electric power transmission. It has been found that main transformer failures require an in-depth assessment because of the high failure frequency and the resultant reliability and safety implications. Transformers are considered as a critical equipment because of the large quantity of oil in contact with high voltage elements. In particular, experience has shown an increasing number of transformer explosions and fires in all types of power plants worldwide. Therefore, these phenomena have been investigated and are discussed in more detail in this paper with regard to causes for these events, potential influence of the age of the transformers and possible diagnostic measure in order to avoid such events. For that purpose different types of databases have been evaluated.
Źródło:
Journal of Polish Safety and Reliability Association; 2010, 1, 1; 35--42
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oszacowanie zawilgocenia izolacji celulozowej na podstawie zawartości wody w oleju
: Estimation of moisture content in cellulose insulation on the basis of moisture content in oil
Autorzy:
Bocheński, B.
Lutkowski, F.
Powiązania:
https://bibliotekanauki.pl/articles/156525.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator energetyczny
izolacja papierowo-olejowa transformatora
zawilgocenie
power transformer
paper-oil transformer insulation
moisture content
Opis:
W referacie przedstawiony został problem pomiaru zawilgocenia izolacji celulozowej w transformatorze z izolacją papierowo-olejową oraz możliwości oszacowania jej na podstawie zawartości wody w oleju. Ponadto w referacie zaprezentowane zostały wyniki prac nad opracowaniem modelu numerycznego migracji wody z izolacji celulozowej do oleju i zastosowanie ich w opracowanym programie komputerowym.
The objective of this paper is to present the problem of measuring moisture content in paper insulation of a power transformer. Even though there is still no possibility of taking direct measurement of moisture content in the cellulose insulation, it can be estimated based on measurement result of moisture content in the oil. Additionally, some equations which were formulated for modeling water migration between cellulose and oil are given.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 11, 11; 773-776
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie klasyfikatora neuronowego w systemie eksperckim oceny stanu układów izolacyjnych transformatorów elektroenergetycznych
The Application of a Neural Classifier in an Expert System for the Evaluation of the Condition of Power Transformer Insulation System
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153524.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
sieci neuronowe
system ekspercki
układ izolacyjny
transformator elektroenergetyczny
partial discharge
artificial neural network
expert's system
paper-oil insulation
power transformer
Opis:
Tematyka artykułu dotyczy oceny możliwości wykorzystania jednokierunkowej sieci neuronowej w systemie eksperckim diagnostyki stanu układów izolacyjnych transformatorów elektroenergetycznych. W artykule przedstawiono teoretyczne i praktyczne możliwości budowy systemu ekspertowego, bazującego na metodzie emisji akustycznej, wspomagającego diagnostykę układów izolacyjnych transformatorów dużej mocy. Zamieszczone w pracy wyniki przedstawiają skuteczność rozpoznawania badanych form WNZ (defektów izolacji), uzyskaną przy zastosowaniu klasyfikatora neuronowego, jak również ocenę możliwości jego zastosowania jako mechanizmu wnioskującego komputerowego systemu diagnostycznego.
The subject matter of the paper refers to the evaluation of the application possibilities of a single-direction neural network in the expert system of the diagnostics of the insulation system condition. The paper presents theoretical and practical possibilities of building an expert system based on the acoustic emission method, assisting the diagnostics of insulation systems of high power transformers. The results presented in this paper show the recognition effectiveness of the PD forms under study (insulation defects), obtained by using a neural classifier as well as the evaluation of its application possibilities as an inferring mechanism of a computer diagnostic system.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 10, 10; 29-32
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of the AC/HF/DC converter with power factor correction
Autorzy:
Bogdan, A.
Powiązania:
https://bibliotekanauki.pl/articles/141404.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
korekcja współczynnika mocy
obwód rezonansowy
transformator wysokiej częstotliwości
przekształtnik podwyższający napięcie
power factor correction
resonant circuit
high frequency transformer
boost converter
Opis:
In this paper, the power factor correction system consisted of: bridge converter, parallel resonant circuit, high frequency transformer, diode rectifier and LFCF filter is presented. This system is controlled by a pulse density modulation method and the principle of its operation is based on the boost technique. The modeling approach is illustrated by an example using AC/HF/DC converter. Verification of the derived model is provided, which demonstrated the validity of the proposed approach.
Źródło:
Archives of Electrical Engineering; 2010, 59, 3-4; 141-152
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka rdzenia transformatora elektroenergetycznego z wykorzystaniem zmodyfikowanej metody wibroakustycznej
Diagnosis of power transformer core using the modified vibroacoustic method
Autorzy:
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/153865.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
rdzeń
diagnostyka
analiza czasowo-częstotliwościowa
drgania
metoda wibroakustyczna
power transformer
core
diagnosis
time and frequency domain analysis
vibration
vibroacoustic method
Opis:
Genezę podjętych w artykule prac stanowi problem skutecznej oceny stanu technicznego konstrukcji mechanicznej rdzeni transformatorów elektroenergetycznych. W publikacji zaprezentowano wyniki wskazujące na możliwość opracowania nowej i bezinwazyjnej metody diagnostycznej rdzeni z wykorzystaniem zaproponowanej przez autora tzw. zmodyfikowanej metody wibroakustycznej (MVM). Zamieszczone w artykule oryginalne rezultaty badań uzyskano podczas prób laboratoryjnych z wykorzystaniem transformatora olejowego o mocy 200 kVA.
The problem of effective assessment of the technical condition of power transformer core mechanical structure originated the research work discussed in this paper. The investigation results show the possibility of developing a new and non-invasive diagnostic method for the transformer magnetic circuit. The method developed is based on time-frequency analysis of measured mechanical vibrations of the device monitored. The recording of vibrations is performed during the monitored transformer no-load operation. The paper characterises the power object under study (Fig. 1), the measuring system applied and discusses the new methodology for assessing the core technical condition using the modified vibroacoustic method (MVM). The original measurement results presented in the paper were obtained during switching on a 200 kVA transformer under laboratory conditions. The analysis of the signals measured was carried out for three operating conditions of the transformer under study: with the core pressed by a manufacturer; with the core with loose screws fixing the upper yoke (Fig. 2a) and with the core with loose screws fixing the upper and lower yokes (Fig. 2b). The research results (Figs. 3-5) obtained from this experiment show a potential possibility of developing a non-destructive and effective method for assessing the technical condition of the core mechanical structure of transformer units operating in the electric power system, especially the ones of a strategic character.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 331-334
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka stanu technicznego obwodu magnetycznego transformatorów energetycznych z wykorzystaniem zmodyfikowanej metody wibroakustycznej
Diagnostics of technical condition of power transformer magnetic circuit with use of a modified vibroacoustic method
Autorzy:
Borucki, S.
Cichoń, A.
Skubis, J.
Powiązania:
https://bibliotekanauki.pl/articles/153431.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
drgania mechaniczne
metoda wibroakustyczna
rdzeń
power transformer
mechanical vibrations
vibroacoustic method
core
Opis:
W publikacji scharakteryzowano zaproponowaną metodykę, tzw. zmodyfikowaną metodę wibroakustyczną, oraz przedstawiono rezultaty badań uzyskane na dwóch transformatorach, jednostce typu TR 16000/110 i TORb 25000/110. Ocenę efektywności opracowanej metodyki pomiarowo – diagnostycznej przeprowadzono poprzez korelację wyników analizy czasowo – częstotliwościowej zarejestrowanych wibracji z rezultatami badań chromatograficznych (DGA) oleju elektroizolacyjnego pobranego z kadzi monitorowanych urządzeń. Analizę zarejestrowanych drgań wykonano z wykorzystaniem przekształceń STFT, CWT i DWT.
The subject of the paper concerns evaluation of the technical condition of the power transformer magnetic circuit by measuring and analyzing vibrations recorded during switching on the transformer. This paper presents the results of technical verification of the noninvasive method used for diagnostics of transformer cores. The research on application of this method has been performed at the Institute of Power Engineering of the Opole University of Technology for several years. The paper characterizes the proposed methodology, the so-called modified vibroacoustic method, and presents the results obtained on two tested transformers, type TR 16000/110 and TORb 25000/110. Evaluation of the effectiveness of the developed methodology of diagnostic measurements was performed by correlation analysis of the time-frequency vibrations recorded with the results of chromatographic studies (DGA) of oil taken from the transformer tank. The recorded vibrations were analyzed using the transformation STFT (Short Time Fourier Transform), CWT (Continuous Wavelet Transform) and DWT (Discrete Wavelet Transform). On the basis of the results given in this paper as well as the currently conducted research work, it was found that there is a real possibility of using the developed method for noninvasive assessment of technical condition of mechanical construction of power transformer cores in operating conditions.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 102-105
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów energetycznych z wykorzystaniem metody wibroakustycznej
Diagnostics of Power Transformers Using the Vibroacoustic Method
Autorzy:
Borucki, S.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155761.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator energetyczny
drgania
rdzeń
metoda wibroakustyczna
diagnostyka
power transformer
vibration
core
vibroacoustic method
diagnostic
Opis:
Tematyka artykułu dotyczy diagnostyki rdzeni transformatorów elektro-energetycznych dużej mocy z wykorzystaniem pomiarów drgań wibroaku-stycznych. W artykule, na podstawie analizy drgań mechanicznych kadzi, dokonano oceny stanu technicznego czterech transformatorów blokowych typu TFBb 240000/400. Scharakteryzowano układ pomiarowy, który został wykorzystany podczas rejestracji sygnałów pochodzących od przenoszonych przez kadź drgań rdzenia poszczególnych jednostek. W oparciu o przyjęte w artykule wartości kryterialne podjęto próbę oceny stanu technicznego diagnozowanych urządzeń elektroenergetycznych.
During its operation a power transformer is subjected to the influence of numerous unfavourable factors which shorten its operation time and can cause unexpected disastrous failures. As far as the active part of a transformer is considered, magnetostrictic vibrations and cellulose depolymerization are the most harmful factors causing the loss of mechanical strength. Their influence results in the gradual loosening of the pressing and clamping of the core and transformer windings, which leads to the weakening of the active part mechanical construction (Fig. 1). In the electric power sector there are a few methods for detection of damages in power transformers. One of them is the vibroacoustic method which consists in measurement and analysis of vibrations of the object under study. Its application to high-power transformer diagnostics enables, first of all, assessing the technical condition of the core. Additionally, combining this method with other diagnostic methods can provide information not only on the core technical condition but also on the solid insulation properties of the device being tested [5 - 6]. In the paper the technical assessment of the condition of four unit transformers of type TFBb 240000/400 is performed basing on the analysis of mechanical vibrations of the tub. The basic technical parameters of the transformers are listed in Table 1. The measuring system used for recording the signals coming from the core vibrations of the particular units and transferred by the tub is described. Based on the criterion values [among others 6 - 8] an attempt to assess the technical condition of the electric power appliances diagnosed is made. The investigations and analyses carried out confirm that the measurement results of vibrations of the particular units have not revealed any damage to their cores or other defects of mechanical character.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies