Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "phase measurement" wg kryterium: Temat


Wyświetlanie 1-36 z 36
Tytuł:
Simultaneous measurement of refractive index and thickness for optically transparent object with a dual-wavelength quantitative technique
Autorzy:
Xu, X.
Wang, Y.
Xu, Y.
Jin, W.
Powiązania:
https://bibliotekanauki.pl/articles/174666.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
digital holography
phase measurement
cell measurement
red blood cell
Opis:
We present a new dual-wavelength quantitative measurement approach that can be employed for simultaneously measuring both the refractive index and the thickness of the homogenous specimen. This method is realized by dual-wavelength in-line phase-shifting digital holography, and then the phase images are obtained by using four-phase step algorithm for each wavelength separately. Based on computer simulation technology, the feasibility and the effectiveness of our proposed method are demonstrated by comparing our simulation results with the experimental results of the spherical silica bead and the red blood cell, respectively. Our work will provide some guidance in the experimental research for transparent phase objects.
Źródło:
Optica Applicata; 2016, 46, 4; 597-605
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method for measuring the quality parameters of image intensifier based on projecting phase-shifting gratings
Autorzy:
Sun, S.
Cao, Y.
Chen, C.
Fu, G.
Wang, Y.
Xu, X.
Powiązania:
https://bibliotekanauki.pl/articles/174300.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phase measurement
phase-shifting grating
distortion
image intensifier
imaging quality parameter
Opis:
A method for measuring the quality parameters of image intensifier based on projecting phase-shifting gratings is proposed. A set of designed phase-shifting gratings are projected into the measuring system orderly to obtain the magnification parameter of the measured image intensifier, and the phase caused by the measured image intensifier. After obtaining the referential phase caused by only the magnification of the measured image intensifier, the phase caused by the distortion of the measured image intensifier is extracted by phase calculating and phase unwrapping. Both the global distortion and the partial distortion of the measured image intensifier can be measured by phase-to-distortion matching at the same time. The experimental results show that the proposed method can measure the multiple quality parameters of image intensifier effectively.
Źródło:
Optica Applicata; 2018, 48, 1; 39-51
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja wielokanałowego systemu rejestracji danych
A concept of a multi-channel data recording system
Autorzy:
Kowalski, J.
Powiązania:
https://bibliotekanauki.pl/articles/155831.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
FPGA
PXI
pomiar 3 fazowy
akwizycja danych
3-phase measurement
data acquisition
Opis:
Artykuł jest propozycją rozwiązania problemu budowy wielokanałowego szybkiego systemu akwizycji danych. System zaprojektowano, jako jednostkę monitującą, rejestrującą dane przez wiele godzin. Nowatorskie w tym podejściu jest zastosowanie 3 połączonych ze sobą systemów, FPGA, systemu czas rzeczywistego RT oraz komputer klasy PC. Połączenie to zapewniło dużą częstotliwość próbkowania, przy długim czas monitorowania danych. Zbudowano system, który umożliwia 8 kanałowy 16 bitowy pomiar z częstotliwością próbkowania 200Ksps.
The paper presents a device which is a solution to the problem of fast, long term, simultaneous measurements of energetic values. The system is designed for monitoring 3-phase voltage and current values of the tested load. It consists of tree autonomic devices: FPGA, a real - time platform and a PC computer. This rare combination enables recording fast-distortion signals caused by switching or failure of a part of the power network. This is possible by using high speed acquisition in FPGA. The measured signals are stored on a hard disk with support of a real time operating system. To simplify the user control, all system commands, indicators and preview of the measured signal are sent by a TCP-IP protocol to the PC computer used to control all processes. The introduction is presented in Section 1. The requirements and limitations of the project are specified in Section 2. The hardware used in the project is described in Section 3 divided in Subsection 3.1 which describes the industrial platform PXI and Subsection 3.2 presenting the FPGA data acquisition card. The IDE which was used to develop the system is described in Section 4. Section 5 deals with the work of the system and connection between the devices. Subsection 5.1 is focused on the operating system on PXI, Subsection 5.2 presents the idea of two operating systems, Subsection 5.3 describes the application on the acquisition FPGA - card, Subsection 5.4 presents the idea of a multi thread application of PXI and Subsection 5.5 describes the control-application on PC. In Section 6 there is presented an example of the measured signals. Section 7 contains the conclusions.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1301-1303
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method for improving the precision of on-line phase measurement profilometry
Autorzy:
Mao, Z
Cao, Y
Zhong, L
Cao, S
Powiązania:
https://bibliotekanauki.pl/articles/174406.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
information optics
Stoilov's algorithm
phase measuring profilometry (PMP)
on-line phase measurement profilometry (OPMP)
phase-shifting
pixel matching
Opis:
An on-line phase measurement profilometry based on improved Stoilov’s algorithm is proposed to measure the 3D shape of moving object. While only one frame sinusoidal grating is projected on the moving object, the equal phase-shifting step deformed patterns modulated by profile of the measured object can be captured at every equivalent moving distance of the measured object instead of digital phase-shifting. Stoilov’s algorithm is an equal phase-shifting step algorithm at an arbitrary phase-shifting step, which is suitable for on-line phase measurement profilometry. However, the arbitrary phase-shifting step of Stoilov’s algorithm depends on the captured deformed patterns, in which the digitized errors of digital light projector or CCD camera, and the disturbance of surrounding light could be introduced, it will lead to some abnormities in wrapped phase, such as the denominator in Stoilov’s algorithm could be zero, which could cause the reconstructed 3D profile of the measured object appear burr, distortion or aberration, even could not be reconstructed. So an on-line phase measurement profilometry based on improved Stoilov’s algorithm is proposed. The arbitrary phase-shifting step is retrieved by both pixel matching and fringe cycle calibration rather than the captured deformed patterns. Experiments verify the feasibility and effectiveness of the proposed on-line phase measurement profilometry.
Źródło:
Optica Applicata; 2015, 45, 1; 51-61
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An automatic system for measurement of impedance active component using a quasi-balanced method
Autorzy:
Barwinek, S.
Cichy, A.
Powiązania:
https://bibliotekanauki.pl/articles/114468.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
virtual instruments
LabVIEW
capacitance measurement
impedance measurement
resistance measurement
phase shift measurement
Opis:
The paper presents the idea of the possibility of implementing automatic virtual instrument using the quasi ˗ balanced method to measure the active component of impedance (resistance). The system is based on the structure of a non-bridge quasi-balanced circuit. The process of balancing is automatically performed. This meter has been built based on the data acquisition board NI USB-6251 from National Instruments and programming environment LabVIEW. Signal processing is made in an algorithmic way. The measurement of the phase angle is based on short-term Fourier transform. The results of preliminary experimental research are presented in the paper.
Źródło:
Measurement Automation Monitoring; 2015, 61, 5; 132-135
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar różnicy faz sygnałów napięciowych
Phase measurements of voltage signals
Autorzy:
Czubla, A.
Stępniewski, J.
Konopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/151438.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
precyzyjny pomiar fazy
metrologia czasu i częstotliwości
precise phase measurement
time and frequency metrology
Opis:
W niniejszym referacie przedstawiona została teoria i praktyka pomiaru różnicy faz sygnałów napięciowych za pomocą częstościomierza-czasomierza cyfrowego. Szczególną uwagę zwrócono na czynniki mające bezpośredni wpływ na wartość i niepewność wyniku pomiaru oraz zapro-ponowano sposób zminimalizowania ich wpływu. W efekcie uzyskano zweryfikowane i spójne wyniki pomiaru różnicy faz sygnałów napięciowych wykonanych za pomocą częstościomierza-czasomierza, w pełni wykorzystując dużą precyzję pomiaru czasu.
In this paper, we present the theory and practical aspects of phase measurements of voltage signals with usage of universal time and frequency counter. Special attention is turned to the factors which influence directly the final value and uncertainty of measurement's result. We propose a method of reducing their influence. As a result, we obtain verified and consistent results of phase measurements of voltage signals performed with a universal time and frequency counter, using to the full its high precision for time measurements.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 81-82
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method for improving sinusoidal quality of error diffusion binary encoded fringe used in phase measurement profilometry
Autorzy:
Tian, Z.
Chen, W.
Su, X.
Powiązania:
https://bibliotekanauki.pl/articles/174421.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phase measurement profilometry
digital-light-processing projector
DLP projector
error diffusion algorithm
binary encoded grating
Opis:
Insufficient resolution of digital-light-processing projector will degrade the sinusoidal quality of the binary encoded fringe pattern because of less sampling points in a fringe period, which will degrade the measurement accuracy if it is used in phase measurement profilometry. Two resolutions are proposed in the paper. One is that a cylindrical lens is introduced in the projecting light path of the measurement system to improve sinusoidal quality of the binary encoded fringe by elliptical low-pass filtering of the system. The other one is that superposition of multi-frame binary encoded gratings with different microstructure is to reduce the binary image noise for improving the measurement accuracy. Simulations and experiments verify the validity of the above two methods.
Źródło:
Optica Applicata; 2016, 46, 2; 291-303
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of optical to mography parameters for gas bubble shape analysis
Autorzy:
Rząsa, M.R.
Powiązania:
https://bibliotekanauki.pl/articles/185491.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bubble shape
gas flow
optical
tomography
two-phase measurement
kształt bańki
przepływ gazu
tomografia
pomiar dwufazowy
Opis:
An optical tomograph in which a tested object is illuminated from five directions has been presented in the paper. The measurements of luminous intensity after changing into discrete signals (0 or 1) in the detectors equipped with 64 optical sensors were subjected to reconstruction by means of the matrix algorithm. Detailed description of the measuring sensor, as well as the principles of operation of the electronic system, has been given in the paper. Optical phenomena occurring at the phase boundary while transmitted through the sensor wall and phenomena inside the measuring space have also been taken into account. The method of the sensor calibration has been analysed and a way of technical solution of the problem under consideration has been discussed. The elaborated method has been tested using objects of the known shape and dimensions. It was found that reconstruction of the shapes of moving bubbles and determination of their main parameters is also possible with a reasonable accuracy.
Źródło:
Chemical and Process Engineering; 2014, 35, 1; 19-33
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ZigBee phase shift measurement approach to mobile inspection robot indoor positioning techniques
Wykorzystanie pomiaru przesunięcia fazowego w transmisji ZigBee do pozycjonowania mobilnych robotów inspekcyjnych
Autorzy:
Śmieja, M.
Powiązania:
https://bibliotekanauki.pl/articles/327998.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
indoor positioning
phase shift measurement
ZigBee
pozycjonowanie w przestrzeniach zamkniętych
przesunięcie fazowe
Opis:
This paper presents the new approach to ZigBee ranging against the background of currently using techniques. This new approach involves a phase shift measurement instead of standard time of arrival or radio signal strength approaches. The ZigBee device used in this study and preliminary tests of ranging and positioning performed using phase shift measurements are presented. The positioning results encourages for further research on the performance verification and algorithms for processing of ranging results.
W artykule przedstawiono zmodyfikowane w stosunku do najczęściej obecnie stosowanych podejście do określania położenia obiektów wykorzystujące propagacje sygnały w protokole ZigBee. Typowe rozwiązania stosowane aktualnie w systemach lokalizacji opartych o bezprzewodowe sieci wymiany danych bazują na pomiarach czasu propagacji lub mocy sygnału. Opisane w artykule podejście odwołuje się do pomiaru przesunięcia fazowego sygnału wynikającego z wykorzystania do transmisji różnych częstotliwości. Przedstawione w artykule wstępne wyniki eksperymentów uzasadniają dalsze prace nad wykorzystaniem przedstawionej metody w zakresie opracowania algorytmów obliczeniowych pozycjonowania oraz weryfikacji efektów w warunkach rzeczywistych.
Źródło:
Diagnostyka; 2018, 19, 3; 101-107
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza statystyczna sygnałów w radioizotopowych pomiarach przepływów dwufazowych
Statistical signal analysis in the radioisotope two-phase flow measurements
Autorzy:
Petryka, L.
Hanus, R.
Zych, M.
Powiązania:
https://bibliotekanauki.pl/articles/157032.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary przepływów dwufazowych
metody jądrowe
metoda źródeł zamkniętych
korelacja wzajemna
faza wzajemnej gęstości widmowej mocy
two phase flow measurement
radioisotopes
sealed sources method
cross-correlation
phase of cross-spectral density function
Opis:
W artykule omówiono wybrane metody analizy sygnałów stosowane w radioizotopowych absorpcyjnych pomiarach parametrów przepływów dwufazowych: metodę korelacji wzajemnej i metodę fazy wzajemnej gęstości widmowej mocy. Na wybranych przykładach pokazano wykorzystanie obydwu metod do pomiaru prędkości przepływu fazy gazowej w mieszaninie woda-powietrze transportowanej rurociągiem poziomym. Wyznaczono i porównano niepewności wyników pomiarów prędkości uzyskane przy zastosowaniu prezentowanych metod.
The paper presents gamma absorption methods applied to two-phase flow evaluation by advanced statistical analysis of the recorded stochastic signals. Two selected methods based on the cross-correlation function and the phase of the cross-spectral density distributions are considered. The examples illustrate application of the specified functions to measurement of velocity of the gas phase transported by water in a horizontal pipe. Moreover, the uncertainties of the velocity measurement results obtained by using both statistical methods presented are calculated and compared.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 12, 12; 866-868
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single parallel stubs as broadband microwave phase shifters
Autorzy:
Rutkowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/220484.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase shift
differential phase shift
microwave phase shifter
parallel stub
instantaneous frequency measurement
IFM
Opis:
Structures and characteristics of wideband small-size phase shifters made with the use of single parallel stubs are presented in this paper. The stubs can be short-circuited or open-circuited on termination. Such devices are well known, but are primarily used as components of filters or matching circuits. The novelty, then, comes from the establishment of simple, but helpful formulae, which enable to describe the insertion phase shift and differential phase shift of a line with short and open stubs connected in parallel. These equations can be very useful for designing complex microwave multi-ports. The results of simulations and measurements of the devices, which were designed and made, are shown herein. It was also proved that the presented device shave several usable operating frequency sub-bands, and that the differential phase shift values in the higher sub-bands are greater than those in the lower operating frequency ranges. Thanks to this, the described phase shifters can be used in more than one frequency sub-band. It was stated that in the conditions under analysis, larger phase shifts can be achieved using open-circuited stubs rather than short-circuited stubs. However, the phase shifters with shorted parallel stubs can operate in a wider frequency band.
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 91-102
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A concept of a passive radar with quadrature microwave phase discriminators
Autorzy:
Rutkowski, A. K.
Powiązania:
https://bibliotekanauki.pl/articles/221600.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
passive radar
instantaneous frequency measurement
IFM
microwave phase discriminator
phase of noise signal
Opis:
Passive radar does not have its own emitter. It uses so-called signals of opportunity emitted by non-cooperative illuminators. During the detection of reflected signals, a direct signal from a non-cooperative emitter is used as the reference signal. Detection of electromagnetic echoes is, in present day radars, performed by finding the maximum of the cross ambiguity function. This function is based on the multiplication of the received signal and the reference signal. Detection of echoes by means of a quadrature microwave phase discriminator QMPD was proposed in the work as an alternative solution for ambiguity function evaluation. This discriminator carries out vectorial summing of the received and the reference signals. The summing operations in QMPD are carried out with the aid of microwave elements and without the use of expensive digital signal processors. Definitions of the phase and phase difference of the so-called simple signals and noise signals were described. A proposal of a passive radar equipped with several independent quadrature microwave phase discriminators was presented. Ideas of algorithms of object detection and of the distance-to-object estimation designed for this radar have been also sketched.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 95-104
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wideband Nine-Port Reflectometer
Autorzy:
Odrobina, S.
Staszek, K.
Wincza, K.
Gruszczynski, S.
Powiązania:
https://bibliotekanauki.pl/articles/227101.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multiport measurement technique
reflectometer
reflection coefficient
measurement uncertainty
directional coupler
power divider
phase shifter
Opis:
The paper presents a wideband nine-port reflectometer realized as a cascade connection of six- and five-port reflectometers. It is shown that such a solution allows for a convenient adjustment of circuits’ parameters in order to provide significantly reduced measurement uncertainty with respect to other reported reflectometers. Simultaneously, the proposed network features a simple and flexible design. For the experimental verification, the proposed nine-port reflectometer has been manufactured and incorporated into the system intended for reflection coefficient measurements within the frequency range 2.5 - 3.5 GHz. The obtained results are in an excellent agreement with the values measured using a commercial VNA.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 1; 19-25
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Introduction of three-dimensional measurement technologies developed and applied in suzuki motor corporation
Autorzy:
Yamage, Y.
Aoki, T.
Hashimoto, T.
Rövid, A.
Shibahara, T.
Akatsuka, S.
Suzuki, H.
Takeshi, M.
Ono, M.
Powiązania:
https://bibliotekanauki.pl/articles/385092.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
image measurement
3D measurement
Direct
Linear Transformation (DLT) methods
Phase-Only Correlation
(POC) function
Opis:
Suzuki Motor Corporation (SMC) recognizes the importance of collaborative projects with Universities and how it contributes to technological development effectively. In spite of the world economical depression, several projects could get started this year leaded by SMC. As a researcher of SMC, Author takes charge of two collaborative projects and introduces these as typical examples of the most successful collaborations. The first is, "3D Measurement System for Crash Tested Car" at Shizuoka University (Japan) and Budapest Tech Polytechnical Institute (Hungary) from 2008; the second is, "High-Accuracy Stereo Vision System Based on Phase-Only Correlation (POC) and Its Application to metal Component Inspection" with Tohoku Univ. (Japan) 2003-2005. By these collaborations, the profound knowledge of universities has a lot of possibility to suits the technical needs of SMC.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 220-223
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Extended Version of the Proportional Adaptive Algorithm Based on Kernel Methods for Channel Identification with Binary Measurements
Autorzy:
Fateh, Rachid
Darif, Anouar
Safi, Said
Powiązania:
https://bibliotekanauki.pl/articles/2142314.pdf
Data publikacji:
2022
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
binary measurement
BRAN channel identification
kernel methods
PNLMS
phase estimation
Opis:
In recent years, kernel methods have provided an important alternative solution, as they offer a simple way of expanding linear algorithms to cover the non-linear mode as well. In this paper, we propose a novel recursive kernel approach allowing to identify the finite impulse response (FIR) in non-linear systems, with binary value output observations. This approach employs a kernel function to perform implicit data mapping. The transformation is performed by changing the basis of the data In a high-dimensional feature space in which the relations between the different variables become linearized. To assess the performance of the proposed approach, we have compared it with two other algorithms, such as proportionate normalized least-meansquare (PNLMS) and improved PNLMS (IPNLMS). For this purpose, we used three measurable frequency-selective fading radio channels, known as the broadband radio access Network (BRAN C, BRAN D, and BRAN E), which are standardized by the European Telecommunications Standards Institute (ETSI), and one theoretical frequency selective channel, known as the Macchi’s channel. Simulation results show that the proposed algorithm offers better results, even in high noise environments, and generates a lower mean square error (MSE) compared with PNLMS and IPNLMS.
Źródło:
Journal of Telecommunications and Information Technology; 2022, 3; 47--58
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wind tunnel flux comparisons using a phase Doppler interferometer
Autorzy:
Roten, R.L.
Post, S.L.
Werner, A.
Safa, M.
Hewitt, A.J.
Powiązania:
https://bibliotekanauki.pl/articles/65512.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wind tunnel
flux measurement
Doppler interferometer
phase Doppler system
droplet
Opis:
It is essential to know the movement of droplets in time and space (i.e. flux) when measuring and/or predicting spray drift in agricultural application. A study was performed to assess the flux measurements of a phase Doppler system against a standard monofilament system in a wind tunnel. The primary objectives of the study were to compare flux from a new phase Doppler system against 1.7 mm cotton and 2.0 mm nylon strings at varying wind speeds (1.4, 4.2, 8.3, 12.5, and 16.7 m ⋅ s–1) and spray exposures times (5, 10, 15, 30, and 60 s) with an overarching hypothesis that the active, phase Doppler is able to accurately measure the flux regardless of exposure and spray mass whereas the static string samplers are limited to a maximum retention. The phase Doppler did measure linearly as expected, however strings did not reach a point in which they loss mass; conversely, they appeared to overload with saturation. These findings are believed to be among many variables which influence the variability of previous mass balance studies.
Źródło:
Journal of Plant Protection Research; 2017, 57, 3
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel ultrasonic distance measuring system based on correlation method
Autorzy:
Gądek, K.
Jaraczewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/141521.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic measurements
non-destructive testing
delay measurement algorithm
phase correlation
Opis:
This paper presents an innovative method for measuring the time delay of ultrasonic waves. Pulse methods used in the previous studies was characterized by latency. The method of phase correlation, presented in this article is free from this disadvantages. Due to the phase encoding with the use of Walsh functions the presented method allows to obtain better precision than previous methods. The algorithm to measure delay of the reflected wave with the use of microprocessor ARM Cortex M4 linked to a PC has been worked out and tested. This method uses the signal from the ultrasonic probe to precisely determine the time delay, caused by the propagation in medium, possible. In order to verify the effectiveness of the method a part of the measuring system was implemented in LabVIEW. The presented method proved to be effective, as it is shown in presented simulation results.
Źródło:
Archives of Electrical Engineering; 2014, 63, 3; 385-392
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Uncertainty of Phase Difference Determination in Presence of Bias
Autorzy:
Saranovac, L. V.
Vučijak, N. M.
Powiązania:
https://bibliotekanauki.pl/articles/221324.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sinusoidal electrical signals
phase difference
bias
uncertainty of measurement
MSAL algorithm
Opis:
Determination of the phase difference between two sinusoidal signals with noise components using samples of these signals is of interest in many measurement systems. The samples of signals are processed by one of many algorithms, such as 7PSF, UQDE and MSAL, to determine the phase difference. The phase difference result must be accompanied with estimation of the measurement uncertainty. The following issues are covered in this paper: the MSAL algorithm background, the ways of treating the bias influence on the phase difference result, comparison of results obtained by applying MSAL and the other mentioned algorithms to the same real signal samples, and evaluation of the uncertainty of the phase difference.
Źródło:
Metrology and Measurement Systems; 2016, 23, 4; 603-614
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neural network model for phase-height relationship of each image pixel in 3D shape measurement by machine vision
Autorzy:
Chung, B
Powiązania:
https://bibliotekanauki.pl/articles/173298.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
machine vision
shape measurement
fringe pattern projection
phase-height relationship
neural network
Opis:
In a three-dimensional measurement system based on a digital light processing projector and a camera, a height estimating function is very important. Sinusoidal fringe patterns of the projector are projected onto the object, and the phase of the measuring point is calculated from the camera image. Then, the height of the measuring point is inferred by the phase. The phase-to-height relationship is unique at each image point. However it is nonlinearly different according to the image coordinates. It is also difficult to obtain the geometrical model because of lens distortion. Even though some studies have been performed on neural network models to find the height from the phase and the related coordinates, the results are not good because of the complex relationship. Therefore, this paper proposes a hybrid method that combines a geometric analysis and a neural network model. The proposed method first finds the phase-to-height relationship from a geometric analysis for each image pixel, and then uses a neural network model to find the related parameters for the relationship. The experimental results show that the proposed method is superior to previous neural network methods.
Źródło:
Optica Applicata; 2014, 44, 4; 587-599
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Contact interactions between soil and a corrugated metal sheet in soil-shell structures under construction
Autorzy:
Machelski, Czesław
Powiązania:
https://bibliotekanauki.pl/articles/2073757.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
soil-steel structure
corrugated metal sheet
construction phase
strain gauge
geodetic measurement
Opis:
During the construction of soil-shell objects, large deformations of the shell, which is made of corrugated metal sheet, occur. This enables geodetic techniques to be used when monitoring such objects. On this basis, displacements of selected points of the shell are determined, and it is then possible to obtain bending moments, as shown in this paper. Based on measurements using strain gauges in the circumferential band of the shell, internal forces in steel are estimated. The algorithm given in the paper enables the impact of soil on the shell in the examined objects to be analysed. The proposed method of analysing forces in the contact layer becomes especially useful when the static conditions of the model of a shell, which is considered as a bar submerged unilaterally in the soil medium, are met. The paper indicates the possibility of using both measuring techniques. Calculations include a smaller share of axial forces on the contact impact during the laying phase of the backfill. The paper provides examples of the analysis of built shells and record-breaking objects, with an assessment of the effectiveness of the proposed algorithm. Good mapping of contact forces, which were calculated on the basis of bending moments, was indicated even when there was not a dense grid of measuring points. An important advantage of the algorithm involves reduction of the circumferential band that is separated from the soil-shell system to the bar, which is an element resulting from the division of the structure into subsystems.
Źródło:
Studia Geotechnica et Mechanica; 2022, 44, 1; 1--12
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic Test Bench for Selected Transmission Parameters of Power Line Conductors
Autorzy:
Chruszczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/227032.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LabVIEW
power line measurements
power line communication
amplitude spectrum
phase spectrum
crosstalk measurement
Opis:
This paper presents automatic test bench used for measurement of selected high frequency parameters of a power copper line. The aim is fast estimation of line behavior in context of Power Line Communication (PLC). The hardware interface uses sinusoidal waveform generator, digital oscilloscope and a PC-class computer. The software interface created in LabVIEW environment performs signal processing and data presentation.
Źródło:
International Journal of Electronics and Telecommunications; 2015, 61, 1; 59-65
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of phase jitter in fibre optic time and frequency transfer systems
Autorzy:
Salwik, K.
Śliwczyński, Ł.
Krehlik, P.
Powiązania:
https://bibliotekanauki.pl/articles/221405.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
jitter measurement
phase comparison
fibre optics
time and frequency transfer
bidirectional
optical amplifier
Opis:
The phase jitter enables to assess quality of signals transmitted in a bi-directional, long-distance fibre optic link dedicated for dissemination of the time and frequency signals. In the paper, we are considering measurements of jitter using a phase detector the detected frequency signal and the reference signal are supplied to. To cover the wideband jitter spectrum the detected signal frequency is divided and - because of the aliasing process - higher spectral components are shifted down. We are also examining the influence of a residual jitter that occurs in the reference signal generated by filtering the jitter occurring in the same signal, whose phase fluctuations we intend to measure. Then, we are discussing the evaluation results, which were obtained by using the target fibre optic time and frequency transfer system.
Źródło:
Metrology and Measurement Systems; 2018, 25, 3; 487-497
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deflectometry for phase retrieval using a composite fringe
Autorzy:
Liu, T.
Zhou, C.
Liu, Y
Si, S
Lei, Z.
Powiązania:
https://bibliotekanauki.pl/articles/173892.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wavefront measurement
fringe analysis
phase retrieval
fast Fourier transform (FFT)
multifrequency heterodyne principle
Opis:
An improved deflectometry for wavefront measurement using a composite fringe is proposed to reduce the projection fringes and improve the accuracy. The single composite fringe contains four fringes in different directions. It goes through the tested objects and then is captured by a CCD camera. Two high frequency orthogonal fringe patterns and two single period orthogonal fringe patterns can be obtained from the composite fringe by fast Fourier transform. The unwrapping of the wrapped phase of the high frequency fringe is accomplished by the corresponding single period fringe using a heterodyne method. The wavefront is reconstructed by the integration of partial derivatives. Using only one fringe, the proposed method is more applicable to dynamic wavefront measurement. The experimental results demonstrate that the proposed method can retrieve the complex wavefronts more accurately.
Źródło:
Optica Applicata; 2014, 44, 3; 451-461
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristic pulse detection method for fuzzy area
Autorzy:
Geng, Xin
Du, Baoqiang
Powiązania:
https://bibliotekanauki.pl/articles/2173662.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
frequency measurement
group period
phase coincidence fuzzy area
measurement gate
pomiar częstotliwości
okres grupowy
obszar rozmyty koincydencji faz
bramka pomiarowa
Opis:
In order to achieve higher frequency measurement accuracy, this paper proposed a characteristic pulse detection method of fuzzy area based on the quantized phase processing method of different frequency groups. First, the fuzzy area of the group phase coincidence points continuously moved on the time axis after passing through delay elements. The moving distance, that is, the number of the delay elements was determined by the main clock cycle of the D flip-flop. After that, three groups of phase coincidence detection fuzzy areas in different positions were sent to the digital logic module to extract the edge pulses of the phase coincidence detection fuzzy area. The pulse width is determined by the difference between the clock cycles of the delay elements. The clock cycles of different delay units were adjusted to obtain nanosecond or even picosecond circuit detection resolution. Finally, the pulses generated at the edge of the phase coincidence fuzzy area are taken as the switching signal of the frequency signal counter, so the stability of the gate signal and the accuracy of the gate time measurement are improved. The experimental results show that frequency stability can reach the order of E–13/s. In addition, compared with the traditional measurement method, it is characterized by simple structure, low cost, low noises, and high measurement resolution.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140553
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do pomiarów podstawowych parametrów obwodu trójfazowego
Labolatory stand for measurement the basic parameters of three-phase network
Autorzy:
Dzwonkowski, A.
Roskosz, R.
Wepa, R.
Powiązania:
https://bibliotekanauki.pl/articles/267899.pdf
Data publikacji:
2007
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
parametry obwodu trójfazowego
przetworniki pomiarowe
stanowisko laboratoryjne
three-phase circuit parameters
measurement transducers
laboratory stand
Opis:
W referacie przedstawione zostanie stanowisko laboratoryjne do pomiaru podstawowych parametrów obwodu trójfazowego. Stanowisko jest wyposażone w różnorodne przetworniki i analizator sieci. Zastosowane mierniki i przetworniki pomiarowe są produkcji firmy LUMEL. Klasa dokładności tych przyrządów wynosi 0,5. Są one przeznaczone do pomiarów zarówno sygnałów sinusoidalnych jak i niesinusoidalnych. Zastosowane w stanowisku obciążenie pomiarowe (rezystancyjnoindukcyjne) umożliwia nastawę obciążenia zarówno symetrycznego jak i niesymetrycznego. Omawiane stanowisko umożliwia prezentację różnych problemów związanych z pomiarami parametrów sieci elektroenergetycznej trójfazowej uatrakcyjniając tym samym proces dydaktyczny. Można bowiem przedstawić wszystkie układy do pomiaru mocy czynnej i biernej w układach trójfazowych. Opis i działanie stanowiska zilustrowano wynikami przeprowadzonych pomiarów, zestawionych w tabeli.
The paper presents laboratory stand use for measurement the basic electrical parameters of three-phase network. The stand is equipped in different meters, industrial converters and network analyzer. All used meters and converters are produced by LUMEL Company. Accuracy class of those instruments is 0,5. They can operate in network with sinusoidal and non-sinusoidal signals. The measurements load, used on the stand, enables to adjust the symmetric and asymmetric load. The laboratory stand can be used to demonstrate different problems, connected with measurement basic parameters of three-phase network. The stand also can be used in didactical process – it is possible to preset all schematic diagrams, used in three-phase systems, for measurement active and reactive power. Description and operation of the laboratory stand is illustrated by obtained measurement results, presented in the table.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2007, 23; 37-40
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of stress states in steel rods surfaced by welding
Analiza stanów naprężenia napawanych prętów stalowych
Autorzy:
Winczek, J.
Powiązania:
https://bibliotekanauki.pl/articles/354539.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase transformation
residual welding stresses
stress measurement
surfacing
przemiany fazowe
naprężenia spawalnicze
pomiar naprężeń
napawanie
Opis:
In work is presented a method of calculating elasto-plastic states in thermally loaded rods, which takes into account phase transformations that occur during surfacing by welding. Kinetics of phase transformations during heating and cooling is limited by temperature values at the beginning and at the end of austenitic transformation, while the progress of phase transformations during cooling is determined on the basis of TTT-welding diagram, basing on Johnson-Mehl-Avrami-Kolomogorov law for diffusional transformations and Koistinen-Marburger for martensitic transformation. Stress state of a bar subjected to thermo-mechanical loads is described assuming the planar cross section hypothesis and using integral equations of stress equilibrium of a bar as well as simple Hook’s law. Dependence of stresses from strains is assumed on the basis of tensile curves of particular structures, taking into account the influence of temperature. Computations of strains and stresses are investigated in a rod made of S235 steel, loaded by thermal fields generated by a point welding heat source of different intensities. The analysis of origination and development of plastic strains is carried out. In order to verify correctness of the model, experimental tests are carried out on a rod made of S235 steel surfaced with GMA method with geometry and welding parameters assumed in numerical simulations. Residual stresses, calculated taking into account phase transformations and for homogenous material model, are compared with experimental results.
W pracy przedstawiono sposób obliczeń stanów sprężysto - plastycznych w prętach obciążonych cieplnie, z uwzględnieniem przemian fazowych zachodzących podczas napawania. Kinetykę przemian fazowych podczas nagizewania i chłodzenia limitują wartości temperatur początku i końca austenityzacji. natomiast postęp przemian podczas chłodzenia jest określony w oparciu o spawalniczy wykres ciągłego chłodzenia stali (CTPc-S). bazując na prawach Johnsona-Mehla-Avramiego-Kołomogorova (JMAK) w odniesieniu do przemian dyfuzyjnych i Koistinena-Marburgera dla martenzytycznej. Stan naprężenia pręta poddanego działaniu obciążeń cieplno-mechanicznych opisano przyjmując hipotezę płaskich przekrojów oraz korzystając z całkowych równań równowagi pręta Zależności naprężeń od odkształceń przyjęto na podstawie krzywych rozciągania poszczególnych struktur z uwzględnieniem wpływu temperatury. Wykonano obliczenia pola temperatury, przemian fazowych, odkształceń i naprężeń płaskownika wykonanego ze stali S235, obciążonego punktowym spawalniczym źródłem ciepła o różnej intensywności. Przeprowadzono analizę powstawania i rozwoju odkształceń plastycznych. W oelu weryfikacji poprawności modelu przeprowadzono badania doświadczalne płaskownika wykonanego ze stali S235 napawanego metodą GMA. o geometrii i parametrach napawania przyjętych w symulacjach numerycznych. Porównano naprężenia własne obliczone z uwzględnieniem przemian fazowych oraz dla modelu materiału jednorodnego z wynikami badań doświadczalnych.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 4; 1243-1252
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie warunkowego uśredniania sygnałów w pomiarach kąta przesunięcia fazowego
The application of conditional averaging of signals in phase angle measurements
Autorzy:
Szlachta, A.
Kowalczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/154980.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przesunięcie fazowe
uśrednianie warunkowe
sygnały opóźnione
sygnały zakłócone
phase angle
conditional averaging
measurement models
noised signals
Opis:
W artykule przedstawiono metodę warunkowego uśredniania sygnałów w pomiarach kąta przesunięcia fazowego sygnałów sinusoidalnych zakłóconych. W zaproponowanej metodzie uśredniane są zbiory kolejnych realizacji sygnału opóźnionego. Na podstawie warunkowej wartości średniej według zaproponowanych algorytmów może być wyznaczany poszukiwany kąt przesunięcia fazowego.
The method of phase measurement by conditional averaging of signal has been presented in this paper. The proposed method of a phase shift angle measurement is based on conditional averaging of delayed signals. The phase angle can be determined on the basis of conditional averaging value of elaborated algorithms.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 12, 12; 14-17
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regresyjny algorytm pomiaru wartości kąta przesunięcia fazowego
The regression algorithm for phase angle measurement
Autorzy:
Szlachta, A.
Kowalczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/158033.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
warunkowe uśrednianie sygnałów
algorytm regresyjny
niepewność pomiaru
conditional averaging of signals
phase angle
uncertainty of measurement result
Opis:
W artykule przedstawiono algorytm do pomiaru kąta przesunięcia fazowego, wykorzystujący warunkowe uśrednianie sygnałów.
In this paper the regression algorithm was presented. It works using conditional averaging for phase angle measurement.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 25-26
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niepewność pomiaru kąta przesunięcia fazowego algorytmów wykorzystujących aproksymację liniową
Uncertainty of phase angle measurement of algorithms based on linear approximation
Autorzy:
Szlachta, A.
Dorozhovets, M.
Powiązania:
https://bibliotekanauki.pl/articles/154982.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przesunięcie fazowe
uśrednianie warunkowe
sygnały opóźnione
sygnały zakłócone
niepewność pomiaru
phase angle
delayed signals
models
noised signals
measurement uncertainty
Opis:
W artykule przedstawiono wyniki obliczeń matematycznych i badań symulacyjnych w celu oceny niepewności wyniku pomiaru przesunięcia fazowego metodą warunkowego uśredniania sygnałów dla algorytmów wykorzystujących aproksymację liniową. Omówiono wpływ doboru algorytmu na dokładność uzyskanych wyników wyznaczenia kąta przesunięcia fazowego.
The results of mathematical calculations and simulations for determination of phase measurement uncertainty using conditional averaging of signal method based on algorithms with linear approximation have been presented in the paper. The influence of algorithm selection on accuracy of obtained results has been also discussed.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 12, 12; 18-21
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i przykładowe zastosowanie stanowiska pomiaru i rejestracji prądów i napięć w instalacjach trójfazowych
Design and sample application stand of measurement and registration currents and voltages in three-phase mains
Autorzy:
Uździcki, W.
Chciuk, M.
Bachman, P.
Aksentowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/276799.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiary
rejestracja
napięcie
prąd
moc
sieć trójfazowa
siła skrawania
measurement
recording
voltage
current
power
three-phase mains
cutting force
Opis:
W artykule opisane jest stanowisko do pomiarów i rejestracji podstawowych parametrów sieci trójfazowych. Opisano w nim budowę stanowiska pomiarowego a następnie zależności matematyczne dotyczące mierzonych sygnałów. W końcowej części artykułu przedstawiono wyniki przykładowych pomiarów.
This paper describes a stand to measure and record the basic parameters of the three-phase mains. Describes the construction of measuring stand and mathematical relations of the measured signals. Finally, the paper presents the results of the sample measurements.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 2; 525-529
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A High-Speed Fully Digital Phase-Synchronizer Implemented in a Field Programmable Gate Array Device
Autorzy:
Frankowski, R.
Chaberski, D.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221125.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase synchronizer
delay line
coincidence counting
quantum information
time interval measurement
time-to-digital converters
field programmable gate array (FPGA)
Opis:
Most systems used in quantum physics experiments require the efficient and simultaneous recording different multi-photon coincidence detection events. In such experiments, the single-photon gated counting systems can be applicable. The main sources of errors in these systems are both instability of the clock source and their imperfect synchronization with the excitation source. Below, we propose a solution for improvement of the metrological parameters of such measuring systems. Thus, we designed a novel integrated circuit dedicated to registration of signals from a photon number resolving detectors including a phase synchronizer module. This paper presents the architecture of a high-resolution (~60 ps) digital phase synchronizer module cooperating with a multi-channel coincidence counter. The main characteristic feature of the presented system is its ability to fast synchronization (requiring only one clock period) with the measuring process. Therefore, it is designed to work with various excitation sources of a very wide frequency range. Implementation of the phase synchronizer module in an FPGA device enabled to reduce the synchronization error value from 2.857 ns to 214.8 ps.
Źródło:
Metrology and Measurement Systems; 2017, 24, 3; 537-550
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary napięcia zasilania stojana silnika w napędzie falownikowym
Measurements of stator voltage in the inverter-fed drive system
Autorzy:
Zawarczyński, Ł.
Stefański, T.
Powiązania:
https://bibliotekanauki.pl/articles/314146.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
napęd falownikowy
stojan silnika
napięcie fazowe
napięcie międzyfazowe
pomiar wartości chwilowej
inverter-fed drive system
motor stator
phase voltage
interphase voltage
measurement of temporary values
Opis:
W artykule przedstawiono analizę układów pomiarowych napięć stojana silnika zasilanego z falownika napięcia. Badania eksperymentalne układów pomiarowych przeprowadzono pod kątem oceny ich pasma przenoszenia, właściwości dynamicznych i dokładności pomiaru. Przedstawiono metody pomiaru wartości chwilowych napięć fazowych i międzyprzewodowych. Testy eksperymentalne przeprowadzono na stanowisku badawczym napędu falownikowego z silnikiem asynchronicznym o mocy 2,6 kW.
This paper presents an analysis of the measuring systems of the stator voltage of inverter-fed motor drive system. Experimental tests of measurement systems were carried out to calculate their bandwidth, dynamic properties and accuracy. The methods of measuring the temporary values of the phase voltages and interphase voltages. Experimental tests were carried out on the inverter-fed drive system with asynchronous motor with a power of 2,6 kW.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 1514-1518
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of thermomechanical properties of ferromagnetic NiFega shape memory alloy subjected to pseudoelastic compression test
Badanie właściwości termomechanicznych ferromagnetycznego stopu z pamięcią kształtu NiFeGa w procesie pseudosprężystego ściskania
Autorzy:
Pieczyska, E.
Dutkiewicz, J.
Masdeu, F.
Luckner, J.
Maciak, R.
Powiązania:
https://bibliotekanauki.pl/articles/351312.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zlokalizowane przemiany fazowe
test kompresji
pomiar temperatury
kamera termowizyjna
magnetically controlled shape memory alloys
localized phase transformation
stress-induced transformation
compression test
temperature measurement
infrared camera
Opis:
In the study stress-induced reversible phase transformation in NiFeGa magnetically controlled shape memory alloy subjected to pseudoelastic compression test was investigated. The specimen's mechanical characteristics and temperature changes related to the exothermic martensite transformation and endothermic reverse transformation were measured in contact-less way by using a fast and sensitive infrared camera (IR). It was found that the stress-induced phase transformation process occurs in this alloy in heterogeneous way, since the observed specimen's temperature distribution was not uniform. Stress-strain curves obtained for the first, as well as for the subsequent six loading-unloading compression cycles and their related temperature changes, elaborated as average from the specimen's surface, were analyzed. It was concluded that the stress and the temperature changes developing in the subsequent cycles depend on the applied test conditions, however the highest discrepancies were observed between the first and the second cycles of the compression loading.
W pracy przedstawiono wyniki badań zmian parametrów mechanicznych oraz temperatury stopu Ni54Fe19Ga27, wykazującego magnetyczną pamięć kształtu. Próbki stopu poddawano procesowi pseudosprężystego ściskania. Temperaturę mierzono za pomocą szybkiej kamery termowizyjnej. Stwierdzono, że indukowana naprężeniem przemiana fazowa zachodzi w tym stopie w sposób niejednorodny, a przebieg charakterystyk mechanicznych i zmian temperatury w kolejnych cyklach obciążania i odciążania prówbki zależy od zastosowanej metodyki badawczej.
Źródło:
Archives of Metallurgy and Materials; 2011, 56, 2; 401-408
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimating the Parameters of the Model of a Power Line by Using a Pair of Phasor Measurement Units
Wyznaczanie parametrów modelu linii przesyłowej na podstawie wskazań dwóch synchrofazorów
Autorzy:
Pasierbek, A.
Powiązania:
https://bibliotekanauki.pl/articles/397420.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
estimating the parameters of the model of a power line
application of phasor measurement units
three-phase model of a power line
wyznaczanie parametrów modelu linii elektroenergetycznej
zastosowanie PMU
trójfazowy model linii elektroenergetycznej
Opis:
The paper describes a method for estimating the parameters of the model of a power line by using a pair of phasor measurement units, developed by the author. It describes a three-phase model of a power system element, a derivative of the single-phase model commonly used in power flow estimation applications. The model being proposed describes – independently for each phase – parameters such as shunt self-admittance, shunt trans-admittance and series admittance. By using measurements obtained from a pair on phasor measurement units installed on both ends of a power line, all parameters of the model being described can be estimated.
W publikacji zaprezentowano autorską metodę wyznaczania parametrów modelu linii elektroenergetycznej na podstawie wskazań dwóch urządzeń PMU (ang. phasor measurement unit). Autor zaproponował użycie trójfazowego modelu pojedynczego elementu SEE (system elektroenergetyczny) jako rozwinięcie powszechnie stosowanego w obliczeniach rozpływu mocy modelu jednofazowego. W modelu uwzględniono, niezależnie dla każdej fazy, takie elementy jak: admitancje poprzeczne własne i wzajemne (poprzeczne) oraz admitancje podłużne.
Źródło:
Acta Energetica; 2013, 1; 125-131
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie parametrów modelu linii przesyłowej na podstawie wskazań dwóch synchrofazorów
Estimating the parameters of the model of a power line by means of using a pair of phasor measurement units
Autorzy:
Pasierbek, A.
Powiązania:
https://bibliotekanauki.pl/articles/267939.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyznaczanie parametrów modelu linii elektroenergetycznej
zastosowanie PMU
trójfazowy model linii elektroenergetycznej
estimating the parameters of the model of a power line
application of phasor measurement units
three-phase model of a power line
Opis:
W publikacji Autor zaprezentował autorską metodę wyznaczania parametrów modelu linii elektroenergetycznej na podstawie wskazań dwóch urządzeń PMU (phasor measurement unit). Zaproponował użycie trójfazowego modelu pojedynczego elementu SEE (system elektroenergetyczny), jako rozwinięcie powszechnie stosowanego w obliczeniach rozpływu mocy modelu jednofazowego. W modelu uwzględniono, niezależnie dla każdej fazy, takie elementy jak: admitancje poprzeczne własne i wzajemne (poprzeczne) oraz admitancje podłużne.
The paper describes a method for estimating the parameters of the model of a power line by means of using a pair of phasor measurement units, developed by the Author. It describes a three-phase model of a power system element, a derivative of the single-phase model commonly used in power flow estimation applications. The model being proposed describes – independently for each phase – parameters such as shunt self-admittance, shunt trans-admittance and series admittance. By using measurements obtained from a pair on phasor measrement units installed on both ends of a power line, all parameteres of the model being described can be estimate.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 47-50
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prace profesora Włodzimierza Krukowskiego (1887 - 1941) w dziedzinie układów pomiarowych i ich rola w rozwoju metrologii elektrycznej
The work of Professor Wlodzimierz Krukowski (1887 - 1941) in the field of measurement circuits and their role in the development of electrical metrology
Autorzy:
Warsza, Z. L.
Powiązania:
https://bibliotekanauki.pl/articles/156445.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomocnicze układy laboratoryjne
pomiary rezystancji wewnętrznej akumulatorów
rezystory wzorcowe
kompensator prądu przemiennego
pomiary 3- fazowe mocy
pomiary energii
pomiary strat
auxiliary laboratory systems
battery internal resistance measurement
standard resistors
AC potentiometer
3-phase power measurements
energy losses
power losses
Opis:
Przedstawiono studium o pracach Profesora Politechniki Lwowskiej Włodzimierza Krukowskiego twórcy wielu elektrycznych układów pomiarowych i ich historycznym znaczeniu dla rozwoju metrologii elektrycznej. We wprowadzeniu scharakteryzowano krótko karierę zawodową i dorobek Profesora oraz Jego uczniów i następców. Następnie omówiono Jego prace dotyczące pomocniczych układów laboratoryjnych, w tym: do regulacji napięcia przy sprawdzaniu przyrządów, do eliminacji wpływu prądów upływu izolacji i do pomiaru ogniw wzorcowych i rezystancji wewnętrznej akumulatorów. Przedstawiono Jego podstawowe prace w dziedzinie układów do dokładnych pomiarów rezystancji wzorcowych, kompensatorów prądu stałego i przemiennego oraz przykład patentu do pomiarów mocy w obwodach trójfazowych. Podkreślono ponadczasową rolę prac Profesora w metrologii.
The study about works of Professor Vladimir Krukowski of Lvov Polytechnic, author of many electrical measurement systems and his historical significance for the development of the electrical metrology is presented. The introduction briefly characterizes career and achievements of the Professor, his collaborators and successors. He put an enormous personal and organizational contributions to the development of the electrical measurement techniques in three European countries: Germany, Poland and Ukraine. There are discussed his works concerned with laboratory circuits supporting measurements, including ones for voltage regulation at instrument calibration, for elimination of isolation leakage current impact on measurements, and circuit for the measurement of standard cells and internal resistances of batteries. The main work of prof. Krukowski in the field of high accuracy measuring systems, both the DC and AC, is also discussed. Fundamental work of prof. Krukowski in the field of systems for accurate measurement of standard resistances, DC and AC potentiometers, and an example of a patent for power measurements in three phase circuits are described. Fundamental input to the metrology of prof. Krukowski's works is underlined.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 1, 1; 144-153
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-36 z 36

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies