Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "oxidation process" wg kryterium: Temat


Tytuł:
Advanced oxidation processes for food industrial wastewater decontamination
Autorzy:
Krzemińska, D.
Neczaj, E.
Borowski, G.
Powiązania:
https://bibliotekanauki.pl/articles/123725.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
advanced oxidation process
wastewater
food industry
Opis:
High organic matter content is a basic problem in food industry wastewaters. Typically, the amount and composition of the effluent varies considerably. In the article four groups of advanced processes and their combination of food industry wastewater treatment have been reviewed: electrochemical oxidation (EC), Fenton’s process, ozonation of water and photocatalytic processes. All advanced oxidation processes (AOP`s) are characterized by a common chemical feature: the capability of exploiting high reactivity of HO radicals in driving oxidation processes which are suitable for achieving decolonization and odour reduction, and the complete mineralization or increase of bioavailability of recalcitrant organic pollutants.
Źródło:
Journal of Ecological Engineering; 2015, 16, 2; 61-71
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation induced degradation of Congo red dye: a mechanistic study
Autorzy:
Muner, Majid
Saeed, Muhammad
Bhatti, Ijaz Ahmad
Haq, Atta-ul
Khosa, Muhammad Kaleem
Jamal, Muhammad Asghar
Ali, Saddaqat
Powiązania:
https://bibliotekanauki.pl/articles/146490.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Congo red
radiolytic product
irradiation
advanced oxidation process
Opis:
Synthetic dyes are persistent pollutants with poor biodegradability. The present study is about the degradation of direct Congo red dye in aqueous media using the Co-60 gamma radiation source. The experimental conditions such as gamma-ray absorbed doses, amount of oxidant (H2O2) and pH conditions were evaluated. The lambda max of dye solution was noted as 498 nm, and then, decrease in absorbance and reduction in chemical oxygen demand (COD) were examined. The complete colour removal of dye was observed at 5 kGy, while a signifi cant COD removal was observed at 15 kGy gamma-ray absorbed dose in conjunction with oxidant for 50 mg/L concentration. It was found that pH has no influence on degradation efficiency. A possible degradation pathway was proposed. The radiolytic end products were monitored by Fourier transform infrared (FTIR) and gas chromatography coupled with mass spectrometry (GC-MS) to explore the degradation mechanism. It was imperative to study the oxidative degradation pathway to provide directions for potential applicability of advanced oxidation process (AOP) in industrial wastewater treatment.
Źródło:
Nukleonika; 2019, 64, 2; 49-53
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Batch and Continuous Photo-Fenton Oxidation of Reactive-Red Dye from Wastewater
Autorzy:
Hassan, Ali A.
AlJaberi, Forat Yasir
Al-Khateeb, Raid T.
Powiązania:
https://bibliotekanauki.pl/articles/2025725.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
dye
wastewater treatment
advanced oxidation process
central composite design
optimization
Opis:
This paper aims to investigate the ability of photo-Fenton technology to remove Reactive Red dye (RR-dye) from wastewater using batch and continuous operating modes. The batch mode of photo-Fenton removal of organic content was conducted under the influence of solution pH (3–10), hydrogen peroxide (25–100 ppm), irradiation time (20–90 min), ferrous sulphate (5–20 ppm), and temperature (25–60 °C). For comparison, the continuous treatment was conducted under the influence of the flow rate of the contaminated solution (10, 20, 30, 40, and 50 mL/min). The results revealed that the treatability of the batch mode was more effective compared to the continuous mode. In the batch process, the organic contaminant was completely removed compared to that of 82% obtained when the continuous system was performed. The optimization process showed that the optimal values of the operating variables in the case of the batch removal of RR-dye were 3, 78 ppm, 90 min, 20 ppm, and 60 °C for pH, hydrogen peroxide, irradiation time, ferrous sulphate, and temperature, respectively. Moreover, the reversion F-value was 21.69, the probability P value was less than 0.001, and the correlation coefficient was (R2 = 0.9455), which illustrative the significance of the model obtained for the batch process.
Źródło:
Journal of Ecological Engineering; 2022, 23, 1; 14-23
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integrated Ozone and Anoxic-Aerobic Activated Sludge Reactor for Endek (Balinese Textile) Wastewater Treatment
Autorzy:
Suryawan, I. Wayan Koko
Siregar, Mia Juliana
Prajati, Gita
Afifah, Anshah Silmi
Powiązania:
https://bibliotekanauki.pl/articles/124354.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
low-biodegradable wastewater
ozone oxidation process
anoxic-aerobic activated sludge
Opis:
The endek industry produces low-biodegradable wastewater, which is very difficult to treat using the biological methods. For this reason, this study was aimed at improving the quality of wastewater for endek textile wastewater using the combination of ozone oxidation process as pretreatment and anoxic-aerobic activated sludge. The ozone reactor volume amounted to 3L and the applied ozone dose equaled 0.05 mg/minute. The BOD/COD of endek wastewater increased to 0.38 after ozone treatment and the application of anoxic-aerobic activated sludge treatment. The anoxic-aerobic experiments were conducted in batch process and consisted of activated sludge. Conventional anoxic-aerobic treatment can reach color and COD removal of 30% and 32%, respectively, without pre-treatment. The ozone pretreatment can increase color and COD removal up to 76.6% and 86.9%, respectively. On the basis of the effluent standards of textile wastewater quality, COD, BOD5, and total ammonia (NH3-N) parameters have met the quality standards.
Źródło:
Journal of Ecological Engineering; 2019, 20, 7; 169-175
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pretreatment of Stabilized Landfill Leachate Using Ozone
Autorzy:
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124499.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
landfill leachate
ozonation
hydrogen peroxide
ultrasonic field
advanced oxidation process
Opis:
The paper presents the possibility of using the ozonation process in landfill leachate pretreatment. The study was conducted in three stages. In the first stage, the landfill leachate was subjected only to the ozone, with the dose varying from 10 mg/dm3 to 40 mg/dm3. As part of this stage of research, the effect of changes in the pH of wastewater undergoing the process of ozonation on the efficiency of TOC removal was examined. For all the tested pH values (pH = 3.5, pH = 7 pH = 8.5 pH = 10), the TOC removal rate constant (kRowo) during ozonization was determined. In the second stage of the study, the ozonation process was facilitated by UV radiation. Additionally in this stage, the rate of generation of OH• radicals was accelerated by the addition of hydrogen peroxide to the reactor. The COD: H2O2 ratio by weight was 1:2.5, 1:5 and 1:10 and 1:20. In the last stage of the study, we attempted to assist the ozonation process using ultrasonic field. The employed vibration amplitude amounted to 25μm and sonication time equalled 300 seconds. It was found that the ozonation process is the most effective at alkaline pH (8.5). The TOC removal efficiency was 37% (346 mg/dm3) after 60 minutes of ozonation. The best results of pollutants oxidation measured as COD and TOC removal were observed when the dose of ozone was 20 mg/dm3. The combination of sonication and ozonation has resulted in a reduction of COD and TOC values by 370 mg/dm3 and 126 mg/3, respectively, in comparison to the ozonation process alone. It was found that the most effective process in landfill leachate treatment is the combination of ozonation with hydrogen peroxide addition (COD:H2O2=1:10). The COD, TOC and BOD values were 65%, 62% and 36% lower, respectively, in comparison to ozonation process conducted alone.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 186-193
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany ilościowe WWA w ściekach oczyszczonych podczas utleniania
Changes of PAHs content in wastewater during oxidation process
Autorzy:
Włodarczyk-Makuła, M.
Powiązania:
https://bibliotekanauki.pl/articles/1819528.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki oczyszczone
proces utleniania
WWA
PAHs
treated sewage
oxidation process
Opis:
Obecność WWA w ściekach potwierdzają doniesienia literaturowe i badania własne. Wykazano, że najbardziej obciążone tymi związkami są ścieki pochodzące z przeróbki paliw (koksownicze, petrochemiczne) [1, 2]. Potwierdzono także, w mniejszych stężeniach, występowanie WWA w ściekach komunalnych i bytowych [3, 4]. Dlatego udział ścieków przemysłowych decyduje o zawartości WWA w ściekach dopływających do oczyszczalni. W niektórych przypadkach do oczyszczalni wprowadzane są także ścieki deszczowe, które również zawierają WWA [5]. W prawnych przepisach dotyczących ścieków odprowadzanych do środowiska podano dopuszczalne wartości dla lotnych węglowodorów aromatycznych BTX, węglowodorów ropopochodnych oraz adsorbowanych związków chloroorganicznych AOX. W odniesieniu do WWA nie wyznaczono wartości dopuszczalnych. Jednak ze względu na wielokrotnie potwierdzone rakotwórcze, mutagenne i teratogenne właściwości należy je zaliczyć do substancji szczególnie szkodliwych dla środowiska wodnego, które należy eliminować [6, 7]. Z drugiej strony wymienia się WWA w przepisach prawnych dotyczących monitoringu wód powierzchniowych [8]. Ze względu na to, że WWA nie są usuwane w procesach oczyszczania ścieków w wystarczającym stopniu, ścieki odprowadzane do odbiorników mogą wnosić znaczny ładunek tych zanieczyszczeń [4]. W wodach powierzchniowych są kumulowane w organizmach wodnych i osadach dennych [9, 10]. Mimo tego, że WWA zaliczane są do ksenobiotyków w określonych warunkach środowiska podlegają przemianom biologicznym i fizyczno-chemicznym [11, 12]. Wśród procesów zachodzących bez udziału mikroorganizmów wymienia się takie, w wyniku których ulegają przemieszczeniu do innego środowiska, takie, które prowadzą do destrukcji WWA oraz takie, w wyniku których powstają nowe związki. Ponadto WWA ulegają sorpcji na cząstkach stałych [13]. W przypadku zabsorbowanych WWA, eliminacja tych związków z wody i ścieków polega na usuwaniu zawiesin np. z wykorzystaniem metod membranowych (ultrafiltracja, odwrócona osmoza) [14, 15]. Migracja do innego środowiska następuje podczas ulatniania WWA do atmosfery lub wymywania z materiałów stałych przez opady atmosferyczne [16, 17]. Pochodne WWA powstają w wyniku reakcji z innymi składnikami matrycy (fluorowcowanie, nitrowanie, sulfonowanie, alkilowanie, acylowanie) [18]. Procesy destrukcji WWA skupiają się wokół chemicznego utleniania i fotodegradacji [19, 20]. Proces fotolizy wydaje się być jednym z obiecujących procesów w usuwaniu WWA z wody i ścieków. Efektywność usuwania WWA w tym procesie były przedmiotem badań własnych [21]. Utlenianie chemiczne można prowadzić z wykorzystaniem rodnika hydroksylowego z odczynnika Fentona, ozonu, nadmanganianu czy ditlenku diwodoru. Celem badań opisanych w niniejszym artykule było określenie zmian WWA w ściekach podczas działania silnego utleniacza jakim jest ditlenek diwodoru.
The presence of PAHs in wastewater is by literature reports and own investigations. It was proved that their highest content is found in wastewater from the treatment of fuels (coke, petrochemicals) [1, 2]. It was also confirmed in lower concentrations, PAHs are present in municipal sewage [3, 4]. There-fore, the share of industrial wastewater determines the content of PAHs in sewage inflowing to treatment plants. In some cases, the rainwater also inflows to treatment plants, which also contains PAHs [5]. The investigations were carried out using wastewater from a municipal sewage treatment plant. The samples of wastewater were primarily characterized for concentration of selected indicators. Chemical oxidation process using hydrogen peroxide in two doses was carried out. Changes in the concentration of PAHs were determined in wastewater samples before and after adding chemical reagent. A quantitative analysis of PAHs was provided by GC-MS. The extraction of organic matrices from wastewater samples was done by the mixture of the organic solvents used (methanol, cyclohexane and dichloromethane). The extracts were separated from samples, purified on silica gel and concentrated under nitrogen stream. 16 PAHs according to EPA were determined. The limit of detection was in the range from 0.14 to 0.59 ?g/L. The sum of 16 PAHs in wastewater taken from a municipal sewage treatment plant was 1.39 ?g/l in average. After chemical oxidation process decrease in PAHs concentration in the samples was observed. Addition of hydrogen peroxide resulted in a decrease in the concentration of PAHs in wastewater coming from sewage treatment plant up to 51-59%. The efficiency of the removal of hydrocarbons grouped according to a number of rings was different (0%-64%).
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1093-1104
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transformation of Traditional Wastewater Treatment Methods into Advanced Oxidation Processes and the Role of Ozonation
Autorzy:
Nikbeen, Tamana
Nayab, Ahmad Khalid
Powiązania:
https://bibliotekanauki.pl/articles/24201749.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment
traditional oxidation method
ozonation
advanced oxidation process
disinfection by-product
micropollutants
Opis:
Technology advancement improves the quality of life, however, it might also introduce new pollutants to the ecosystem, which needs to deal with for the goal of a sustainable ecosystem. Municipal and industrial wastewater has always been important in improving the quality of life while maintaining the sustainability of our planet simultaneously. The diversity of pollutants in wastewater requires more advanced and demanding treatment processes. The ozonation, as a crucial part of the advanced oxidation processes, is a superior oxidation method compared to traditional oxidation methods. After the recognition of ozone as GRAS (generally recognized as safe), its applications have diversified and is used currently for microbial inactivation, degradation of recalcitrant organic compounds, removal of a diverse range of micropollutants, solubilization and reduction of sludge, and removal of color and odor components in wastewaters treatment processes. However, some considerable challenges still exist towards its universal application, such as high ozone generation costs, diversity of pollutants, and formation of ozonation by-products, which still require further studies. The main theme of this review paper is the transformation of traditional oxidation methods into advanced oxidation processes and the role of ozonation in this regard, including its applications, by-products, and its comparison with the traditional oxidation methods and advanced oxidation processes.
Źródło:
Journal of Ecological Engineering; 2023, 24, 6; 173--189
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie procesu ozonowania w oczyszczaniu ścieków koksowniczych
The Use of Ozonation Process in Coke Wastewater Treatment
Autorzy:
Kwarciak-Kozłowska, A.
Krzywicka, A.
Gałwa-Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818115.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki koksownicze
ozonowanie
zaawansowane metody utleniania
coke wastewater
ozonation
advanced oxidation process
Opis:
The paper presents presents the possibility of using the ozonation process in coke wastewater treatment. The wastewater produced during processing of coke was initially pre-treated mechanically in order to remove solid impurities, oils and tar substances. The raw wastewater was characterized by the phenolic odor, brown color and alkaline pH (pH 9.2). The COD value of raw wastewater was 8100 mg/dm3 and the value of BOD was very low (180 mg/dm3). A high concentration of total nitrogen (2420 mg/dm3) and TOC (2240 mg/dm3) was also noted. The study was conducted in three stages. In the first stage, coking wastewater was treated only by ozone, the dose of which varied from 10 mg/dm3 to 40 mg/dm3. The effect of pH during ozonation process was determined on TOC removal efficiency. For all of the pH values (pH = 3.5, pH = 7, pH = 8.5 and pH = 11.5) the TOC removal rate constant was determined. In the second stage, the rate OH radicals generation was accelerated by the addition of hydrogen peroxide to the reactor. The ratio by weight of COD: H2O2 was 1:2.5, 1:5, 1:10 and 1:20. In the last stage of the study, we attempted to assist the ozonation process with ultrasonic field. The sonication time was 8 minutes and the amplitude was 61.5 μm. It was found that the ozonation process is the most effective at alkaline pH (8.5). The TOC removal efficiency was 34% (1470 mg/dm3) after 60 minutes of ozonation. The best results of oxidation of pollutants measured as COD and TOC removal were observed when the dose of ozone was 30 mg/dm3.The combination of sonication and ozonation has resulted in a reduction of COD and TOC values by 1000 mg/dm3 and 300 mg/dm3, respectively, in comparison to ozonation process alone. It was found that the most effective process in coke wastewater treatment is the combination of ozonation with hydrogen peroxide addition (COD:H2O2=1:10). The COD, TOC and BOD value were 54%, 35% and 20% lower, respectively, in comparison to ozonation process conducted alone.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 61-73
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of Petroleum Refinery Wastewater by Graphite–Graphite Electro Fenton System Using Batch Recirculation Electrochemical Reactor
Autorzy:
Kassob, Ali Nadhum
Abbar, Ali Hussein
Powiązania:
https://bibliotekanauki.pl/articles/2202176.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
advanced oxidation process
COD removal
electro-Fenton
porous graphite
response surface methodology
Opis:
Water pollution and the lack of access to clean water are general global problems that result from the expansion of industrial and agricultural activities. Petroleum refinery wastewaters are considered as a major challenge to the environment and their treatment is mandatory. The present work investigated the removal of chemical oxygen demand (COD) from petroleum refinery effluents generated from the Al-Dewaniya petroleum refinery plant located in Iraq by utilizing a novel graphite–graphite electro-Fenton (EF) system. The electrochemical reactor was a tubular type with a cylindrical cathode made from porous graphite and concentric porous graphite rode acts as an anode. By adopting the response surface methodology (RSM), the impacts of different operating variables on the COD removal were investigated. The optimal conditions were a current density of 25 mA/cm2, FeSO4 concentration of 1.4 mM, and electrolysis time of 90 minutes, which resulted in the COD removal efficiency (RE%) of 99% at a specific energy consumption (SEC) of 10.34 kWh/kg COD. The results indicated that both current density and concentration of FeSO4 have a major impact on the elimination of COD, while time has a minor effect. The adequacy of the model equation was demonstrated by its high R2 value (0.987). The present work demonstrated that the graphite–graphite EF system could be considered as an effective approach for removing of COD from petroleum refinery wastewaters.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 291--303
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ozone Degradation of Lignin; its Impact Upon the Subsequent Biodegradation
Degradacja ligniny w wyniku działania ozonem (AOP) oraz wpływ na późniejszą biodegradację
Autorzy:
Michniewicz, M.
Stufka-Olczyk, J.
Milczarek, A.
Powiązania:
https://bibliotekanauki.pl/articles/233915.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
degradation
lignin
ozone
advanced oxidation process
biodegradation
degradacja
związki ligninowe
ozon
biodegradacja
Opis:
The possible use of ozone and advanced oxidation processes (AOP) to degrade and eliminate lignin compounds from aqueous solutions, and the determination of the required ozone dose are the primary objectives of this study. The influence of the oxidation methods on the subsequent biological decomposition of the by-products was also investigated.During ozonisation of the alkalilignin aqueous solutions, the polymer is degraded to a degree depending on the ozone dose. Lignin content decreased by about 40 to 96.6% at an ozone dose of 0.1 and 3.6 mgO3/mgCOD, respectively, accompanied by a drop of COD in the range of 8.8 - 69.6%. An ozone dose of about 1 mgO3/mgCOD is required to reduce the lignin content by more than 80%; at such a dose, the reduction of COD was about 35%. Lignin proved to be a substance that is practically insusceptible to biodegradation under the test conditions. An increase of the susceptibility to biodegradation of the lignin disintegration products could have been observed at an appropriately high dose of ozone.
Celem badań było sprawdzenie możliwości zastosowania ozonu i procesów pogłębionego utleniania (AOP) do degradacji i usunięcia związków ligninowych z roztworów wodnych oraz określenie wymaganej dawki ozonu. Ponadto przeprowadzono badania wpływu pogłębionego utleniania na dalszą biologiczną destrukcję produktów ubocznych rozkładu ligniny. W wyniku ozonowania wodnych roztworów alkaliligniny, polimer ten ulegał degradacji w stopniu zależnym od dawki ozonu. Redukcja zawartości ligniny była w miała zakresie od ok. 40,0 do 96,6%, przy dawce ozonu odpowiednio 0,1 i 3,6 mg O3/mgChZT. Jednocześnie zakres redukcji ChZT była w zakresie wynosił 8,8 – 69,6%. Dawka ozonu potrzebna do otrzymania redukcji ligniny powyżej 80% wynosi ok. 1 mgO3/mgChZT. Przy tej dawce redukcja ChZT wynosiła ok. 35%. Lignina okazała się substancją praktycznie nie podatną na biodegradację w warunkach prowadzenia testów. Przy odpowiednio wysokiej dawce ozonu stwierdzono wzrost podatności na biodegradację produktów rozpadu ligniny.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 191-196
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of PAHs from municipal wastewater during the third stage of treatment
Usuwanie WWA ze ścieków komunalnych w trzecim etapie oczyszczania
Autorzy:
Włodarczyk-Makuła, M.
Wiśniowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/297035.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
PAHs
GC-MS
wastewater
oxidation process
hydrogen peroxide
WWA
ścieki
proces utleniania
Opis:
The investigations were carried out using wastewater received from a municipal wastewater treatment plant. The samples of wastewater were primarily characterized for concentration of selected physicochemical parameters. Next, a standard mixture of PAHs was added to the samples. Chemical oxidation process was performed using two doses of hydrogen peroxide. Changes in concentration of PAHs were determined in the wastewater samples before addition of the chemical reagent and after the oxidation process. A quantitative analysis of PAHs was provided by GC-MS. The extraction of organic matrices from the wastewater samples was performed using a mixture of organic solvents: methanol, cyclohexane and dichloromethane. The extracts were separated from samples, purified on silica gel and concentrated under nitrogen stream. Concentrations of 16 PAHs according to EPA were determined. The detection limit ranged from 0.14 to 0.59 μg/L. Total concentration of 16 PAHs in wastewater sampled from the treatment plant were 1.4 μg/L on average. Total concentration of 16 PAHs in wastewater with the standard mixture was 561 μg/L on average. A decrease in PAHs concentration was observed in the samples after chemical oxidation process. Addition of hydrogen peroxide resulted in a decrease of 16 PAHs concentration in wastewater coming from the wastewater treatment plant to 61÷74%. The efficiency of hydrocarbons removal, grouped according to the number of rings, ranged from 35 to 90%.
Celem badań było określenie efektywności usuwania WWA ze ścieków podczas ich doczyszczania. W pracy przedstawiono wyniki badań zmian ilościowych WWA w poddawanych utlenianiu ściekach komunalnych oczyszczonych odpływających z miejskiej oczyszczalni ścieków. Oczyszczalnia pracuje jako mechaniczno-biologiczna z chemicznym usuwaniem fosforu. Badania prowadzono po wprowadzeniu do ścieków oczyszczanych dodatkowej ilości WWA w postaci standardowej mieszaniny. Następnie prowadzono proces utleniania zanieczyszczeń organicznych ze szczególnym uwzględnieniem zmian w stężeniu WWA, z wykorzystaniem nadtlenku wodoru. Utleniacz stosowano w postaci 30% roztworu w dawkach wynoszących 2,5 i 5 mg/dm3. Efektywność usuwania WWA określano z uwzględnieniem zawartości początkowej badanych związków oraz dodanej w postaci wzorca. Analizowano stężenia 16 WWA zgodnie z listą EPA. Oznaczenia jakościowo-ilościowe prowadzono z wykorzystaniem chromatografu gazowego ze spektrometrem masowym. W procesie utleniania odnotowano znaczny spadek stężenia badanych WWA w ściekach. Ubytek sumarycznej ilości WWA w ściekach wzbogaconych WWA był w zakresie od 61 do 74%, lecz dla poszczególnych węglowodorów efektywność usunięcia wahała się od 35 do 90%.
Źródło:
Inżynieria i Ochrona Środowiska; 2018, 21, 2; 143-154
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of catalytic processes for biodiesel production wastewater treatment
Autorzy:
Borralho, Teresa
Coelho, Solange
Estrelo, Andreia
Powiązania:
https://bibliotekanauki.pl/articles/205024.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt
chemical oxygen demand
Fenton process
biodiesel production wastewater
catalytic advanced oxidation process
potassium monopersulphate
Opis:
The study of the possibility of removing organic compounds from wastewater originating from the biodiesel purification stage by two catalytic processes, HSO5-/transition metal and Fenton method has been presented. The source of the ion HSO5-is potassium monopersulphate (2KHSO5∙KHSO4∙K5SO4) (Oxone) that may be decomposed into radicals (OH., SO4-., SO5-.) by means of transition metal as Co(II). Different concentrations were used for both compounds and the combination ([Co2+] = 1.00μM/[HSO5-] = 5.00·10-2 M) achieved the highest COD removal (60%) and complete decomposition of the oxidant was verified for contact times of 45 min. This process has some advantages comparing to the conventional Fenton method such as the absence of the costly pH adjustment and the Fe(III) hydroxide sludge which characterize this treatment process. The Fenton process showed that the combination of [H2O2] = 2.00M/[Fe2+] = 0.70 M was the best and archived COD removal of 80%. The treatments studied in this research have achieved high COD removal, but the wastewater from the biodiesel purification stage presents very high parametric values of Chemical Oxygen Demand (667,000 mgO2/L), so the final COD concentration reached is still above the emission limit of discharge in surface water, according the Portuguese Law (Decree-Law 236/98). However, both treatments have proved to be feasible techniques for the pre-oxidation of the wastewater under study and can be considered as a suitable pre-treatment for this type of wastewaters. A rough economic analysis of both processes was, also, made.
Źródło:
Archives of Environmental Protection; 2019, 45, 2; 66-72
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zużycie energii w procesie oczyszczania ścieków z wykorzystaniem metody pogłębionego utleniania
The energy consumption in the process of waste water treatment with usage of advanced oxidation processes
Autorzy:
Kowalczyk, R.
Bąbała, J.
Powiązania:
https://bibliotekanauki.pl/articles/227935.pdf
Data publikacji:
2010
Wydawca:
Wyższa Szkoła Menedżerska w Warszawie
Tematy:
metoda pogłębionego utleniania
zużycie energii
oczyszczanie ścieków
sewage purification
wastewater treatment
oxidation process
Opis:
Badano zużycie energii w procesie oczyszczania ścieków z wykorzystaniem metody pogłębionego utlenienia w podczyszczalni jednego z większych zakładów drobiarskich. Stwierdzono, że w procesie tym zużywa się 2-3 krotnie mniej energii niż w tradycyjnych technologiach oczyszczania w innych porównywalnych zakładach przemysłu spożywczego.
The energy consumption in the process of sewage purification with usage of Advanced Oxidation Processes in treatment plant of waste water ofthe one of bigger poultry-breeding plant was investigated. It was found that in above mentioned process the energy consumption is 2-3 times lower then in traditional technologies of sewage purification in other food industry plants.
Źródło:
Postępy Techniki Przetwórstwa Spożywczego; 2010, 2; 61-63
0867-793X
2719-3691
Pojawia się w:
Postępy Techniki Przetwórstwa Spożywczego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Caffeine degradation in water by gamma irradiation, ozonation and ozonation/gamma irradiation
Autorzy:
Torun, M.
Abbasova, D.
Şolpan, D.
Güven, O.
Powiązania:
https://bibliotekanauki.pl/articles/146514.pdf
Data publikacji:
2014
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
caffeine
effect of ozone
radiolytic decomposition
advanced oxidation process (AOPs)
caffeine decomposition
COD change
Opis:
Aqueous solutions of caffeine were treated with ozone and gamma irradiation. The amounts of remaining caffeine were determined after solid phase extraction as a function of absorbed dose and ozonation time. In addition to this, some important parameters such as inorganic ions, chemical oxygen demand (COD) dissolved oxygen and total acidity changes were followed. Caffeine (50 ppm) is found to be completely decomposed at 3.0 kGy and 1.2 kGy doses in the absence of H2O2 and in 1.20 mM H2O2 solutions, respectively. In the case of gamma irradiation after ozonation, 50 ppm caffeine was removed at 0.2 kGy when the solution was ozonized for 100 s at a rate of 10 g O3 h–1 in 400 mL 50 ppm paracetamol solution.
Źródło:
Nukleonika; 2014, 59, 1; 25-35
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assesment of oxidative stability and melting characteristic of palm oil and cocoa butter
Ocena stabilności oksydacyjnej i charakterystyki mięknięcia oleju palmowego oraz tłuszczu kakaowego
Autorzy:
Ostrowska-Ligęza, E.
Mańko-Jurkowska, d.
Brozio, S.
Wirkowska-Wojdyła, M.
Bryś, J.
Głowacka, R.
Górska, A.
Powiązania:
https://bibliotekanauki.pl/articles/13925546.pdf
Data publikacji:
2019
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
palm oil
cocoa butter
vegetable fat
differential scanning calorimetry
temperature
oxidation process
melting
lipid
triacylglycerol
Źródło:
Zeszyty Problemowe Postępów Nauk Rolniczych; 2019, 596; 45-54
0084-5477
Pojawia się w:
Zeszyty Problemowe Postępów Nauk Rolniczych
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies