Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flux density" wg kryterium: Temat


Tytuł:
Magnetic field of complex helical conductors
Autorzy:
Budnik, K.
Machczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/141527.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Biot-Savart law
magnetic flux density
helical line
Opis:
Transmission of the electric power is accompanied with generation of low –frequency electromagnetic fields. Electromagnetic compatibility studies require that the fields from sources of electric power be well known. Unfortunately, many of these sources are not defined to the desired degree of accuracy. This applies e.g. to the case of the twisted-wire pair used in telephone communication; already practiced is twisting of insulated high-voltage three phase power cables and single-phase distribution cables as well. The paper presents a theoretical study of the calculation of magnetic fields in vicinity of conductors having helical structure. For the helical conductor with finite length the method is based on the Biot-Savart law. Since the lay-out of the cables is much more similar to a broken line than to strait line, in the paper the magnetic flux densities produced by helical conductor of complex geometry are also derived. The analytical formulas for calculating the 3D magnetic field can be used by a software tool to model the magnetic fields generated by e.g. twisted wires, helical coils, etc.
Źródło:
Archives of Electrical Engineering; 2013, 62, 4; 533-540
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chronovoltammetric determination of oxygen flux density in the soil
Autorzy:
Malicki, M.A.
Bieganowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/26357.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
oxygen diffusion
soil
amperometry
oxygen flux density
voltammetry
chronovoltammetry
Źródło:
International Agrophysics; 1999, 13, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault detection and diagnosis of squirrel cage asynchronous motor using a new COMSOL multiphysics software 6.0.
Autorzy:
Djaidir, Benrabeh
Nail, Bachir
Rouibah, Abdelkader
Powiązania:
https://bibliotekanauki.pl/articles/27313810.pdf
Data publikacji:
2024
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
asynchronous motor
comsol multiphysics
diagnosis
fault detection
flux density
Opis:
In this paper, the diagnosis of faults in squirrel cage asynchronous motor and experimental analysis process are presented. Currently there are several simulation tools, that lets users analyze and interpret the behavior of their devices. Based on this, there is a lot of researches that is working on developing models, to detect and classify 3-phase asynchronous motor faults, significantly in the early stages. This work proposed design and experimental analysis established in Comsol Multiphysics 6.0 , which implements finite element analysis software (FEM) for detecting and diagnosing broken bar rotors of this types motors and its practical application. In this case, the post processor of the COMSOL-Multiphysics makes it possible to visualize in 2D the various magnetic and mechanical quantities. Through the curves of the magnetic flux density and analysis distribution of the field with magnetic induction lines, we can draw some conclusions, where we proposed an strategy, for detecting and diagnosing faults consistent with the structure of the software.
Źródło:
Diagnostyka; 2024, 25, 1; art. no. 2024102
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method elaboration for determining heat losses within heat leakage bridges occurring in isothermal and cooling bodies
Autorzy:
Rochatka, T.
Powiązania:
https://bibliotekanauki.pl/articles/114272.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
heat leakage bridge
heat flux density
thermovision
isothermal body
Opis:
This paper presents the author’s method for the heat flux evaluation on the basis of a thermal photograph. This method is based on the comparison of surface temperatures of two areas where one of them is a thermally loaded with a known heat flux and the other control area which is not thermally loaded. With the method presented in the article analysing heat fluxes in places of high heat flux gradients occurring within heat leakage bridges, especially the service ones connected with the material humidity where heat flux density sensors can give substantial errors when the flux on the sensor surface is averaged.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 242-244
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyznaczania i analiza rozkładu indukcji magnetycznej w szczelinie powietrznej silnika indukcyjnego liniowego
Method for Determining and Analysis of the Experimental Air Gap Flux Density in Linear Induction Motor
Autorzy:
Kupiec, E.
Przyborowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1368645.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
indukcja magnetyczna
silnik indukcyjny liniowy
flux density
linear induction motor
Opis:
In this work a measurement system and method for calculating the spatial air gap field distribution in linear induction motor is presented. Way of recording the instantaneous air gap flux density distribution is described. Method of converting the measured signals to obtain the spatial air gap flux density distribution and spatial harmonics is presented. Based on the introduction of parametric variation of time in the form of chase angle, the animation of instantaneous air gap field distribution was generated.
W pracy przedstawiono system pomiarowy oraz metodę wyznaczania przestrzennego rozkładu indukcji w szczelinie silnika indukcyjnego liniowego. Opisano sposób rejestracji czasowo-przestrzennego rozkładu indukcji. Zaprezentowano metodę przekształcenia sygnałów pomiarowych i ich analizę w celu wyznaczenia przestrzennego rozkładu indukcji oraz wyznaczenia harmonicznych przestrzennych. Na podstawie wprowadzenia parametrycznej zmienności czasu w formie kąta fazowego dokonano wizualizacji pomierzonych sygnałów w formie animacji przebiegu czasowo-przestrzennego.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 4, 100/2; 121-126
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research and Assessment of Safety Distance of TV Electromagnetic Fields
Autorzy:
Baltrenas, P.
Buckus, R.
Powiązania:
https://bibliotekanauki.pl/articles/89688.pdf
Data publikacji:
2011
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
electric field strength
magnetic flux density
electromagnetic field
safety distance
Opis:
The evaluation covers the strengths of electric field and magnetic flux denstiy measured in frequency ranges of 5 Hz–2 kHz and 2–400 kHz of selected TV sets. The dependence of the electromagnetic field on the distance is addressed with reference to ergonomics and safety. Ten TV sets (5 tube and 5 LCD) were measured. There were 16 measurements for each one. The aim was to evaluate electric field and magnetic flux denstiy versus the distance from the tested device with regard to exposure levels. In addition, the distance and the strengths of electric field and magnetic flux denstiy emitted by tube and LCD TVs were compared. The results are presented in charts.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2011, 17, 1; 33-39
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental EMC aspects of resistance welding equipment
Autorzy:
Doebbelin, R.
Winkler, T.
Lindemann, A.
Powiązania:
https://bibliotekanauki.pl/articles/262729.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
resistance welding equipment
high output current
magnetic flux density
minimum distance
Opis:
Resulting from the connection between the change rate of a magnetic field and the induced currents in an exposed human body, pulsating magnetic fields have to be evaluated analysing the waveforms of the field or the field-generating current A corresponding assessment guideline is given in the German safety regulation on "Electromagnetic Fields" BGV Bll. Considering the specific output current waveforms of resistance welding installations, in the paper appropriate procedures to determine the waveform-dependent exposure limits are explained by the examples of an a.c. resistance welding machine and a resistance welding inverter. Based on investigations of the field distribution the occurring actual flux density values are compared to the ascertained exposure limits and a practical method to determine minimum distances ensuring compliance with the given regulations is shown.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 2; 41-48
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effektivnost' infrakrasnykh vodjanykh otopitel'nykh panelejj
Water efficiency infrared heating panels
Autorzy:
Cherednik, A.
Redko, A.
Powiązania:
https://bibliotekanauki.pl/articles/76786.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
water management
radiant heating
flux density
air temperature
heat flow
experimental study
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 6
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An investigation of the thermal characteristics of the refrigerants zeotropic mixtures condensation in minichannels
Autorzy:
Bohdal, T.
Sikora, M.
Widomska, K.
Powiązania:
https://bibliotekanauki.pl/articles/175244.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
heat transfer coefficient
mass flux density
minichannels
vapor quality
zeotropic mixture
Opis:
This paper describes the results of experimental investigations of heat transfer during the condensation of the homogenous R134a refrigerant and zeotropic mixtures R404A, R407C and R410A in pipe minichannels with internal diameters 0.31–3.30 mm. The values of the local and average heat transfer coefficient throughout the range of changes in the vapor quality 1–0 were determined. Based on the obtained results, the effect of vapor quality, mass flux density and channel diameter changes on heat transfer coefficient was illustrated. a pronounced effect of the refrigerant properties at the heat exchange efficiency during the condensation process in pipe minichannels was indicated. The results were compared with calculations according to the correlations proposed by other authors. On the basis of the experimental investigations, the authors proposed their own correlation for the calculation of local heat transfer coefficient, obtaining the results of compatibility tests in the range of ±20%.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2015, 128; 43-57
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repeatability of measurements of the potential oxygen flux density in the soil by the voltamperometric method
Autorzy:
Bieganowski, A
Powiązania:
https://bibliotekanauki.pl/articles/1401907.pdf
Data publikacji:
2000
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
soil aeration
measurement
oxygen diffusion rate
soil
oxygen flux density
voltammetry
agrophysics
Opis:
Influence of the measuring procedure on the repeatability of measurement of the potential oxygen flux density in the soil has been presented. Five measuring procedures were applied: measurements taken one directly after another, reinstallation of the electrode after each measurement , reinstallation of the electrode after each measurement with a simultaneous mechanical cleaning of surfaces, measurements with 15-min breaks between consecutive measurements, measurements with electrochemical "cleaning" of the electrode surface.The OFD value was determined by a voltamperometric method using a tri-electrode measuring system. It was found out that the best repeatability can be obtained by repeating the measurement with 15-min (or longer) time intervals.
Źródło:
Acta Agrophysica; 2000, 35
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proba eliminacji elektrody porownawczej w woltamperometrycznej metodzie pomiaru gestosci strumienia tlenu [OFD]
Reference electrode elimination in the woltammetric measurement of the oxygen flux density
Autorzy:
Bieganowski, A
Malicki, M.A.
Powiązania:
https://bibliotekanauki.pl/articles/1630395.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
gleby
gestosc strumienia tlenu
natlenienie
woltamperometria
soil
oxygen flux density
oxygenation
voltammetry
Opis:
Przedstawiono wyniki badań dotyczące pomiarów gęstości strumienia tlenu (OFD) w dwuelektrodowym symetrycznym układzie elektrod platynowych i stalowych. Krzywe woltamperometryczne uzyskane w różnie natlenionych roztworach wskazują na możliwość eliminacji elektrody porównawczej.
Results of measurements of the oxygen flux density (OFD) using symmetric two electrode (platinum or steel) system are presented.Current - voltage curves obtained in differently oxygenated solutions indicate possibility of elimination of reference electrode.
Źródło:
Acta Agrophysica; 1999, 22; 25-30
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The calculations of the efficency of the lightweight floor heating according to nordtest method NT VVS 127
Autorzy:
Werner-Juszczuk, Anna Justyna
Powiązania:
https://bibliotekanauki.pl/chapters/31233737.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
lightweight floor heating
standard
dry floor heating
heat flux density
surface temperature
Opis:
The suitability of Nordest Method NT VVS 127 for determining the operational parameters of the lightweight floor heating with a dry screed was tested. The methodology of surface temperature and heat flux density determination according to Nordest Method NT VVS 127 was presented. The calculations were made for lightweight floor heating with a dry screed of various thickness and variable water temperature. The results were compared with the numerical calculations made with ANSYS Steady-State Thermal Solver. The operational parameters of the floor heating were also determined using the method presented in PN-EN 1264 standard. The difference between the surface temperature determined according to Nordest Method NT VVS 127 and the numerical values does not exceed 5,68 K, for the heat flux density the error is up to 55,5%. The difference between the surface temperature determined according to PN-EN 1264 and the numerical value does not exceed 0,2 K, for the heat flux density the error is up to 8,5%. It was found, that the PN-EN 1264 standard is more applicable to determining the operational parameters of lightweight floor heating with a dry screed than Nordest Method NT VVS 127.
Źródło:
Innovations – Sustainability – Modernity – Openness. Modernity in engineering; 159-172
9788366391901
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental analysis of linear induction motor under variable voltage variable frequency (VVVF) power supply
Autorzy:
Wakode, P. D.
Tariq, M.
Bhattacharya, T. K.
Powiązania:
https://bibliotekanauki.pl/articles/136237.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
Linear Induction Motor
Variable Voltage Variable Frequency
experimental
air gap flux density
Opis:
This paper presents the complete analysis of Linear Induction Motor (LIM) under VVVF. The complete variation of LIM air gap flux under ‘blocked Linor’ condition and starting force is analyzed and presented when LIM is given VVVF supply. The analysis of this data is important in further understanding of the equivalent circuit parameters of LIM and to study the magnetic circuit of LIM. The variation of these parameters is important to know the LIM response at different frequencies. The simulation and application of different control strategies such as vector control thus becomes quite easy to apply and understand motor’s response under such strategy of control.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 2; 18-24
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design of a rotor with a starter-generator integrated into an aero car
Autorzy:
Wu, Zaixin
Yu, Ruiguang
Powiązania:
https://bibliotekanauki.pl/articles/141579.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
aero motor
air-gap flux density
axial segmentation
electromagnetic and heat flux coupling
Halbach array structure
Opis:
The Halbach array structure rotor of the aero motor can satisfy the requirements of high power density and high air-gap flux for aeronautical motors. The size parameters of the rotor are determined by the power rating of the motor based on an analytic method. Producing a Halbach array structure is difficult. Comparison and analysis of the structure of the aero motor showthat the overall structure of the rotor adopts a three-axial-section classic Halbach-array hollow structure, and the rotor magnetic steel adopts a discrete structure of 4 blocks per pole and a single 45◦ magnetisation mode, which reduces the processing difficulty of the rotor magnetic steel. The finite element method was used to analyse the magnetic flux density distribution of the aeronautical motor under various working conditions. The results show that the motor can produce uniform air-gap flux density at various working conditions and present good sinusoidal periodicity. Furthermore, the axial segment did not produce obvious magnetic flux leakage. Finally, considering the eddy current loss of the stator under the rated power-generation condition with high-frequency magnetic field, we conducted coupling analysis of electromagnetic and heat flows to verify that the thermal characteristics of the rotor magnetic steel material could meet the requirements for the aero motor.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 357-371
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Flux Density of the Solar Radio Burst Event by Using Log Periodic Dipole Antenna (LPDA)
Autorzy:
Hamidi, Z. S.
Shariff, N. N. M.
Powiązania:
https://bibliotekanauki.pl/articles/412450.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
sun
CALLISTO
Log Periodic Dipole Antenna (LPDA)
power flux density
solar radio burst
Opis:
In this article, an evaluation of the flux density of the solar radio burst is presented. A rod aluminium’s type as a conductor with nineteenth (19) elements of different sizes is being prepared to construct a log periodic dipole antenna (LPDA) from 45-870 MHz. The performance was carried out at the National Space Agency (PAN), Sg. Lang, Banting Selangor by connecting to the Compound Low Cost Low Frequency Spectroscopy Transportable Observatory (CALLISTO) spectrometer. The input impedance, R0 = 50 ohm is chosen for this LPDA antenna. From the analysis, the gain of the antenna is 9.3 dB. This antenna potentially captures a signal that covers about 0.08 m2 area of the Sun.The temperature of the burst that detected at the feedpoint of the antenna is 32 K. However, the signal becomes decrease to 28.75 K while by CALLISTO spectrometer as a receiver. It was also found that the isotropic source spectral power is 1576 W/Hz. Since the burst level above the background sky is 0.41 dB , the flux density of the burst is 5.5 x 10-21 W/m2/Hz. Based on the results, we conclude that this antenna is suitable for to observe the Sun activities at low frequency region.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 7; 21-29
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis and comparison of PMSM with concentrated winding and distributed winding
Autorzy:
Qiu, Hongbo
Zhang, Yong
Yang, Cunxiang
Yi, Ran
Powiązania:
https://bibliotekanauki.pl/articles/141179.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air-gap flux density
cogging torque
concentrated winding
distributed winding
efficiency
loss
PMSM
Opis:
The concentrated winding (CW) is obviously different from the traditional distributed winding (DW) in the arrangement of windings and the calculation of winding factors, which will inevitably lead to different performances of the permanent magnet synchronous motor (PMSM). In order to analyze the differences between the CW and the DW in the performance, a 3 kW, 1500 r/min PMSM is taken as an example to establish a 2-D finite element model. The correctness of the model is verified by comparing experimental data and calculated data. Firstly, the finite element method (FEM) is used to calculate the electromagnetic field of the PMSM, and the performance parameters of the PMSM are obtained. On this basis, the influences of the two winding structures on the performance are quantitatively analyzed, and the differences between the two winding structures on the performance of the PMSM will be determined. Finally, the differences of efficiency between the two winding structures are obtained. In addition, the influences of the winding structures on eddy current loss are further studied, and the mechanism of eddy current loss is revealed by studying the eddy current density. The analysis of this paper provides reference and practical value for the optimization design of the PMSM.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 303-317
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on the influence of driving harmonic on electromagnetic field and temperature field of permanent magnet synchronous motor
Autorzy:
Qiu, H.
Yu, W.
Li, Y.
Yang, C.
Powiązania:
https://bibliotekanauki.pl/articles/141535.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air gap flux density
eddy current loss
harmonic
magnetic field decoupling
torque ripple
Opis:
At present, the drivers with different control methods are used in most of permanent magnet synchronous motors (PMSM). A current outputted by a driver contains a large number of harmonics that will cause the PMSM torque ripple, winding heating and rotor temperature rise too large and so on. In this paper, in order to determine the influence of the current harmonics on the motor performance, different harmonic currents were injected into the motor armature. Firstly, in order to study the influence of the current harmonic on the motor magnetic field, a novel decoupling method of the motor magnetic field was proposed. On this basis, the difference of harmonic content in an air gap magnetic field was studied, and the influence of a harmonic current on the air gap flux density was obtained. Secondly, by comparing the fluctuation of the motor torque in the fundamental and different harmonic currents, the influence of harmonic on a motor torque ripple was determined. Then, the influence of different current harmonics on the eddy current loss of the motor was compared and analyzed, and the influence of the drive harmonic on the eddy current loss was obtained. Finally, by using a finite element method (FEM), the motor temperature distribution with different harmonics was obtained.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 295-312
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model mikrokrzemowego czujnika z cewką planarną do pomiaru indukcji pola magnetycznego
Microsilicon sensor with planar coil for magnetic flux density measurements
Autorzy:
Prohuń, T.
Rybak, M.
Powiązania:
https://bibliotekanauki.pl/articles/151445.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
MEMS
MOEMS
struktury krzemowe
pomiary indukcji magnetycznej
silicon microstructures
magnetic flux density measurements
Opis:
W artykule przedstawiono model czujnika do pomiaru indukcji stałego (jednorodnego) pola magnetycznego w postaci belki krzemowej z nanie-sionym płaskim uzwojeniem. Prąd przepływający przez uzwojenie cewki wytwarza strumień oddziałujący z zewnętrznym polem magnetycznym. Koniec belki ulega odkształceniu w kierunku osi z. Kąt ugięcia belki jest miarą indukcji zewnętrznego pola magnetycznego. Do analizy zastosowano metodę elementów skończonych oraz metodę pól sprzężonych ze względu na anizotropowość i niejednorodność struktury krzemowej. W pracy opisano charakterystyki wyjściowe czyli kąta ugięcia belki w funkcji indukcji B zewnętrznego pola magnetycznego. Przeanalizowano wpływ wymiarów geometrycznych belki na jej ugięcie.
In the article a magnetic flux density sensor was described. The sensor consist of silicon cantilever and planar coil. Current flowing by the coil produce magnetic flux around the coil. Influence of magnetic flux with external magnetic field causes cantilever deform. The angle of cantilever deformation in z axis means external magnetic field induction. In cause of magnetic anisotropy and heterogeneous of analyzed silicon structure the FEM method and couple field method was applied in simulation. The influence of dimensions of beam on beam-end deformation was described.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 78-80
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie przestrzennego rozkładu pola magnetycznego przetwornika elektromagnetycznego do pomiaru indukcji zewnętrznego pola magnetycznego
Modeling 3D magnetic field of magnetic flux density sensor
Autorzy:
Prohuń, T.
Gołębiowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/157380.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
MEMS
MOEMS
struktury krzemowe
pomiary indukcji magnetycznej
silicon microstructures
magnetic flux density measurements
Opis:
W referacie przedstawiono model czujnika do pomiaru indukcji pola magnetycznego w postaci belki krzemowej z naniesionym płaskim uzwojeniem. Prąd przepływający przez uzwojenie cewki wytwarza strumień oddziałujący z zewnętrznym polem magnetycznym. Koniec belki ulega odkształceniu w kierunku osi z. Kąt ugięcia belki jest miarą indukcji zewnętrznego pola magnetycznego. Model czujnika składa się z belki wykonanej z krzemu monokrystalicznego oraz płaskiego uzwojenia wykonanego z aluminium. Ze względu na wielowarstwową, anizotropową budowę przetwornika do budowy modelu zastosowano metodę elementów skończonych (metodą pól sprzężonych i oprogramowanie COMSOL). W referacie pokazano rozkład przestrzennego pola magnetycznego cewki płaskiej i jego wpływ na zewnętrzne (mierzone) pole magnetyczne. W pracy przedstawiono wyniki symulacji dla różnych wartości parametrów konstrukcyjnych przetwornika w celu uzyskania zakładanej czułości dla wybranego zakresu pomiarowego indukcji zewnętrznego pola magnetycznego.
In the article a magnetic flux density sensor was described. The sensor consist of silicon cantilever and planar coil. Current flowing by the coil produce magnetic flux around the coil. Influence of magnetic flux with external magnetic field causes cantilever deform. The angle of cantilever deformation means external magnetic field induction. The influence of shape and dimensions of planar coil on magnetic energy density was described. In cause of magnetic anisotropy and heterogeneous of analyzed silicon structure the FEM method and couple field method was applied in simulation.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 265-268
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zróżnicowanie strumienia geotermicznego Ziemi w rejonie Tychów (GZW)
Heat flux density distribution in the area of Tychy (USCB)
Autorzy:
Wagner, Jadwiga
Kaczorowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/203685.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
energia geotermalna
strumień cieplny
gęstość strumienia cieplnego
geothermal energy
geothermal stream
heat flux density
Opis:
Model pola cieplnego Ziemi wykonano dla obszaru badań arkusza MhP 0969-Tychy, 1:50 000 wraz z obszarami do niego przyległymi. W interwale głębokości od 0 do 1000 m, w odcinkach stumetrowych, wykonano rozkład temperatury oraz rozkład gęstości strumienia ciepła. Wykorzystano dane archiwalne zamieszczone w dokumentacjach otworów (1950–1990) i pomiary temperatury wykonane w studniach specjalnie dla tej pracy (2010). Interpretacja została wykonana na podstawie bazy danych łącznie z 312 otworów (w tym: 223 otwory badawcze i 89 studni) oraz 880 pomiarów temperatur. W obszarze badań zależnie od: zapotrzebowania inwestora, zagospodarowania terenu i infrastruktury podziemnej – ciepło geotermalne Ziemi – wykorzystać można za pomocą różnych typów instalacji geotermalnych.
A geothermal model of underground heat sources has been constructed for the area of MhP 0969-Tychy, at a scale of 1:50 000. This model includes temperatures, and heat flux density distribution in a 0–1000 m range of depth. The project used the archival data of borehole documentations (produced mainly between 1950 and 1990), as well as temperature measurements taken in wells specifically for this work (2010). The interpretation was based on a database of 312 boreholes (including 223 test boreholes and 89 wells) and 880 temperature measurements. In the area of research, depending on the demands of the investor and land and underground infrastructure, the geothermal heat sources could be accessed using a variety of geothermal installations.
Źródło:
Technika Poszukiwań Geologicznych; 2014, R. 53, nr 1, 1; 71-83
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implications of plant growth regulators on induction of in vitro flowering in Aerva lanata (L.) Juss. ex Schult.
Autorzy:
Shekhawat, Mahipal S.
Manokari, M.
Ravindran, C. P.
Powiązania:
https://bibliotekanauki.pl/articles/1186752.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Aerva lanata
In vitro flowering
Spectral flux photon density
Opis:
In vitro flowering was successfully induced from the shoots regenerated in cultures of Aerva lanata. In vitro flowering method can be monitored effectively in studying floral transition and flower development from vegetative to reproductive phase. The nodal shoot segments were used as explants in the present study. The explants were surface sterilized using HgCl2 and inoculated on Murashige and Skoog’s (MS) medium supplemented with 6-benzylaminopurine (BAP) for bud break. Maximum numbers of shoots were induced on MS medium supplemented with 1.0 mg l-1 BAP. The cultures were multiplied by continuous subculturing of shoots with mother explants on fresh MS medium with BAP and Kinetin (Kin). Rooting was achieved on one fourth MS medium supplemented with 2.0 mg l-1 indole-3-butyric acid (IBA). The multiplied shoots were subjected to various concentrations of different plant growth regulators and photoperiod regimes to induce flowering in vitro. The maximum numbers of in vitro flowers were recorded from the shoots on full strength MS medium with 0.5 mg l-1 BAP and 0.1 mg l-1 indole-3-acetic acid (IAA) on 12/12 h/d photoperiod.
Źródło:
World Scientific News; 2016, 32; 71-81
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous measurement of oxygen flux and salinity of the water saturated mineral soils
Autorzy:
Bieganowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/24164.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
mineral soil
simultaneous measurement
electrical conductivity
saturated soil
oxygen flux
soil oxygen
soil salinity
water
salinity
flux density
Źródło:
International Agrophysics; 2003, 17, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienie wilgotnosci krytycznej w pomiarach potencjalnej gestosci strumienia tlenu w glebie
Autorzy:
Bieganowski, A
Wolinska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1402616.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
gleby
wilgotnosc krytyczna
gestosc strumienia tlenu
tlen
soil
critical water content
oxygen flux density
oxygen
Źródło:
Acta Agrophysica; 2001, 53; 37-45
1234-4125
Pojawia się w:
Acta Agrophysica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of different rotor magnetic circuit structure on the performance of permanent magnet synchronous motor
Autorzy:
Qiu, H.
Yu, W.
YANG, C.
Yi, R.
Powiązania:
https://bibliotekanauki.pl/articles/141061.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air gap flux density
cogging torque
magnetic circuit structure
overload capacity
permanent magnet synchronous motor
Opis:
In order to compare the performance difference of the permanent magnet synchronous motors (PMSM) with different rotor structure, two kinds of rotor magnetic circuit structure with surface-mounted radial excitation and tangential excitation are designed respectively. By comparing and analyzing the results, the difference of the motor performance was determined. Firstly, based on the finite element method (FEM), the motor electromagnetic field performance was studied, and the magnetic field distribution of the different magnetic circuit structure was obtained. The influence mechanism of the different magnetic circuit structure on the air gap flux density was obtained by using the Fourier theory. Secondly, the cogging torque, output torque and overload capacity of the PMSM with different rotor structure were studied. The effect mechanism of the different rotor structure on the motor output property difference was obtained. The motor prototype with two kinds of rotor structure was manufactured, and the experimental study was carried out. By comparing the experimental data and simulation data, the correctness of the research is verified. This paper lays a foundation for the research on the performance of the PMSM with different magnetic circuit structure.
Źródło:
Archives of Electrical Engineering; 2017, 66, 3; 583-594
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena doboru sieci neuronowej do określania występowania i wyznaczania zakresu quasiplateau w woltamperometrycznych pomiarach natlenienia gleby
Assessment of the selection of neural network used to show the occurrence and to determine quasiplateau range in volt-ampere-metric soil oxygenation measurements
Autorzy:
Bartnik, G.
Marciniak, A. W.
Bieganowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/287583.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
sieć neuronowa
OFD
natlenienie gleby
gęstość strumienia tlenu
neural network
soil oxygenation
oxygen flux density
Opis:
Wartość natlenienia gleby jest określana m.in. w oparciu o pomiarowo dostępne krzywe woltamperometryczne I(U), a konkretnie o występowanie i zakres plateau na tych krzywych. Celem pracy było zaprojektowanie sieci neuronowej, która w sposób automatyczny identyfikowałaby te krzywe I(U), które są interpretowalne w kategoriach natlenienia gleby, tzn. występuje na nich plateau oraz, w przypadku występowania, określała granice napięć, przy których to plateau występuje. W ten sposób elektrochemiczny układ pomiarowy zostanie wzbogacony o "inteligentny" moduł umożliwiający dalsze, obiektywne obliczenia.
Among others, soil oxygenation value is determined on the basis of available measurements of volt-ampere-metric curves I(U), and specifically on the basis of plateau occurrence and range in these curves. The purpose of the work was to design a neural network that would automatically identify these curves I(U), which are interpretable in terms of soil oxygenation, that is they have a plateau. Moreover, the network would determine voltage limits, at which this plateau occurs, provided that it occurs. Thus, the electrochemical measurement system will be provided with an extra "intelligent" module allowing to perform further, objective computations.
Źródło:
Inżynieria Rolnicza; 2008, R. 12, nr 7(105), 7(105); 7-14
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies