The concentrated winding (CW) is obviously different from the traditional distributed winding (DW) in the arrangement of windings and the calculation of winding
factors, which will inevitably lead to different performances of the permanent magnet synchronous motor (PMSM). In order to analyze the differences between the CW and the DW
in the performance, a 3 kW, 1500 r/min PMSM is taken as an example to establish a 2-D
finite element model. The correctness of the model is verified by comparing experimental
data and calculated data. Firstly, the finite element method (FEM) is used to calculate the
electromagnetic field of the PMSM, and the performance parameters of the PMSM are
obtained. On this basis, the influences of the two winding structures on the performance
are quantitatively analyzed, and the differences between the two winding structures on the
performance of the PMSM will be determined. Finally, the differences of efficiency between
the two winding structures are obtained. In addition, the influences of the winding structures
on eddy current loss are further studied, and the mechanism of eddy current loss is revealed
by studying the eddy current density. The analysis of this paper provides reference and
practical value for the optimization design of the PMSM.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies