Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ekg" wg kryterium: Temat


Tytuł:
The EKG signal measurement and the influence of alpine conditions on heart actions
Autorzy:
Sapota, G.
Wróbel, Z.
Powiązania:
https://bibliotekanauki.pl/articles/333688.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG
GPRS
Opis:
This work presents the possibility of measuring heart action parameters in the alpine conditions as well as the measuring system, which helps to measure and transmit EKG signal with the aid of GPRS net. The GPRS transmission makes the estimation of heart action on - line possible. Thanks to it, it is possible to monitor the reaction of human organism being on a certain level of height. GPRS net application enables the measuring in the whole world. The charge for using this net is only dependent on the quantity of transmitted data which needs the signal compression. This work also mentions the possibility of compression use, which takes the advantage of temporal and frequency decomposition.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 7; KB99-103
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method in the Chaos – a step-by-step approach to ECG interpretation
Autorzy:
Kozłowski, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/895823.pdf
Data publikacji:
2018-09-28
Wydawca:
Gdański Uniwersytet Medyczny
Tematy:
EKG
ECG
interpretation
how-to
guide
Opis:
According to the expert opinion of the Working Group on Noninvasive Electrocardiology and Telemedicine of the Polish Cardiac Society, the interpretation (and report) of an electrocardiogram (ECG) consists of 10 steps. For the sake of simplicity, it is possible to simplify these rules to 7 steps. The aim of this article is to help refresh the clinical aspects of ECG interpretation and to hopefully clarify the confusion surrounding it.
Źródło:
European Journal of Translational and Clinical Medicine; 2018, 1, 1; 76-92
2657-3148
2657-3156
Pojawia się w:
European Journal of Translational and Clinical Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Voltage Quality on Asynchronous Motor Performance of EKG Excavator in Open Pit Mines – Vinacomin
Wpływ jakości napięcia na wydajność silnika asynchronicznego koparki EKG w kopalniach odkrywkowych Vinacomin
Autorzy:
Ngo, Xuan Cuong
Do, Nhu Y.
Tran, Quang Hieu
Powiązania:
https://bibliotekanauki.pl/articles/318392.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
power quality
harmonic
nonsinusoidal voltage
EKG excavators
jakość energii
napięcie harmoniczne
napięcie niesinusoidalne
koparki EKG
Opis:
At present, in open-pit mining, the main and most important electrical load is the electric excavator, and currently using a variety of EKG excavators. 6kV electrical network in open pit mining has the characteristics such as long outgoing lines, use high-powered equipment, multiple branches, and increasing use of power electronics on the grid, this reduces the quality of the power supplied to the excavators EKG, resulting in an increase in power losses thereby greatly affecting the performance of the excavators. Previous studies on the quality of the power supplied to the excavator often only mentioned voltage deviations, in addition to this factor, the performance of the excavator is also greatly affected by nonsinusoidal voltage waveforms of the excavator power supply. This paper analyzes the influence of the nonsinusoidal of voltage on the power loss of electric motors used in EKG electric excavators in open pit mining based on the method of electromagnetic analysis and verification on simulation software.
Obecnie, EKG są powszechne koparki stosowane w kopalnictwie odkrywkowym Wietnamu. Sieć elektryczna 6kV w kopalniach odkrywkowych ma takie cechy, jak długie linie wychodzące, zastosowanie sprzętu o dużej mocy, wiele odgałęzień co obniża jakość energii dostarczanej do koparek EKG, skutkując wzrost strat mocy, co znacząco wpływa na wydajność koparek. Dotychczasowe badania jakości energii dostarczanej do koparki często wskazywały tylko na odchylenia napięcia. W artykule, przeanalizowano wpływ napięcia niesinusoidalnego na straty mocy silników elektrycznych stosowanych w koparkach elektrycznych EKG w górnictwie odkrywkowym w oparciu o metodę analizy elektromagnetycznej i weryfikacji w oprogramowaniu symulacyjnym.
Źródło:
Inżynieria Mineralna; 2020, 1, 2; 139-145
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany w zapisie EKG u chorych na cukrzycę zakwalifikowanych do operacji pomostowania aortalno-wieńcowego
ECG changes in diabetes patients qualified for coronary artery bypass grafting surgery
Autorzy:
Brazevic, S.
Grajek, M.
Kopyciuk, T.
Powiązania:
https://bibliotekanauki.pl/articles/261379.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
CABG
EKG
cukrzyca
BMI
ECG
diabetes
Opis:
Praca przedstawia wyniki analizy statystycznej danych uzyskanych podczas badania EKG w grupie pacjentów chorych na cukrzycę i zakwalifikowanych do operacji CABG (pomostowanie aortalno-wieńcowe), a także analizę wskaźnika BMI w przebadanej grupie. Na podstawie wyników uzyskanych w badaniu EKG sprawdzano, jaki sposób leczenia cukrzycy typu 1 lub 2 ma korzystniejszy wpływ na stan pacjenta i proces rekonwalescencji. Ponadto dodatkowym celem było określenie istotnych statystycznie zmian patologicznych w zapisie EKG oraz sprawdzenie, czy związane z nimi choroby, takie jak zawał mięśnia sercowego czy nadciśnienie tętnicze, mają również negatywny wpływ na stan pacjenta. Uzyskane wyniki analizy EKG w grupie pacjentów chorych na cukrzycę mają charakter poznawczy, stanowią tylko część przeprowadzonego badania pacjentów z zaawansowaną chorobą niedokrwienną serca i mogą być podstawą wykonania dalszych, bardziej dokładnych badań.
Results of the statistical analysis ECG signals of diabetes patients qualified for CABG (coronary artery bypass grafting), as well as an analysis of BMI in the studied group, are presented. Basing on ECG analysis, the influence of the treatment methods of diabetes type 1 or 2 on patient’s condition and convalescence process, were studied. Furthermore, an additional goal was to determine statistically significant pathological changes in ECG and verification if associated diseases, such as myocardial infarction and hypertension also have a negative impact on the patient's condition. ECG analysis in case of patients with diabetes may be a part of further extended research on patients with advanced coronary artery.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2015, 21, 3; 177-184
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czułość i swoistość elektrokardiograficznej oceny przerostu mięśnia serca u chorych z pierwotnym nadciśnieniem tętniczym powyżej 60. roku życia
Autorzy:
Młynarczyk, Jagoda
Gać, Paweł
Mazur, Grzegorz
Sobieszczańska, Małgorzata
Poręba, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/552147.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Przyjaciół Medycyny Rodzinnej i Lekarzy Rodzinnych
Tematy:
nadciśnienie tętnicze
przerost mięśnia sercowego
EKG
geriatria
Źródło:
Family Medicine & Primary Care Review; 2016, 1; 29-32
1734-3402
Pojawia się w:
Family Medicine & Primary Care Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integralny wskaźnik niebezpieczeństwa jako inicjator interpretacji EKG w systemach monitorowania na żądanie
Integral emergency indicator as a trigger for the on-demand cardiac monitoring
Autorzy:
Augustyniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/261703.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
EKG
kardiologia
system monitorowania
cardiology
monitoring system
Opis:
Poszukiwania optymalizacji ekonomicznej oraz możliwości wykorzystania doświadczenia eksperta kardiologa w systemach nadzoru pacjenta w warunkach domowych zaowocowały m.in. koncepcją interpretacji na żądanie. Zakłada ona inicjowanie interpretacji kolejnych fragmentów zapisu EKG w momentach bezpośrednio poprzedzających termin ważności wartości obliczonych poprzednio. Niestety, stan pacjenta nie jest stały w czasie i jego gwałtowne pogorszenie może spowodować zbyt rzadkie uaktualnianie interpretacji, co w przypadku ostrego przebiegu patologii kardiologicznych może zagrażać ciągłości monitorowania. W systemach autoadaptacyjnych przydatny jest zatem dodatkowy czynnik kontrolujący występowanie nagłych zagrożeń. W rezultacie analizy złożoności obliczeniowej wstępnych etapów przetwarzania elektrokardiogramu, w kontekście siły związku zmian wynikowych parametrów diagnostycznych z najczęstszymi patologiami, zaproponowany został złożony wskaźnik niebezpieczeństwa oparty na częstości akcji serca i stałości ośrodka pobudzającego. Prostota obliczeń pozwala na zaimplementowanie detektora w osobistym rejestratorze, bazującym np. na telefonie komórkowym, bez istotnego wpływu na czas jego autonomicznej pracy.
Combining economical requirements and the necessity of using the expertise of cardiologist, influences the development of a request-driven ECG interpretation method. It is assumed that the processing of the acquired ECG is triggered by the data validity period expiry or by the emergency detector continuously supervising basic parameters of the signal. This paper focuses on the correct choice of the emergency detector procedure covering a wide range of diseases, but not requiring much computational power in the patient-side wearable system. After the examination of numerical complexity of the initial stages of ECG processing and checking the presence of most common diseases in basic cardiac parameters, we propose a short-term rhythm index as an emergency indicator. The computation is simple enough to be performed in a limited-resources environment (e.g. mobile phone) without considerably influencing its autonomy time.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 2; 154-157
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jak uporządkować chaos, czyli interpretacja EKG krok po kroku
Autorzy:
Kozłowski, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2151979.pdf
Data publikacji:
2019-12-31
Wydawca:
Gdański Uniwersytet Medyczny
Tematy:
ECG
EKG
interpretacja
przewodnik
heptalog
siedem kroków
Opis:
Zgodnie ze stanowiskiem grupy ekspertów Sekcji Elektrokardiologii Nieinwazyjnej i Telemedycyny Polskiego Towarzystwa Kardiologicznego podstawowa zasada opisu elektrokardiogramu obejmuje dziesięć punktów. Dla lepszej przejrzystości można skrócić zasady podstawowego opisu EKG do 7 kroków. Celem niniejszego artykułu jest odświeżenie klinicznych aspektów interpretacji EKG oraz (mam nadzieję) wyjaśnienie niepewności z tym związanych.
Źródło:
European Journal of Translational and Clinical Medicine; 2019, 2, Suppl. 2; 1-23
2657-3148
2657-3156
Pojawia się w:
European Journal of Translational and Clinical Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Software Platform for Combined Analysis of Weather Data and Holter Monitoring Data
Autorzy:
Kotas, R.
Kamiński, M.
Mazur, P.
Cieślik-Guerra, U.
Sakowicz, B.
Marańda, W.
Piotrowicz, M.
Kurpesa, M.
Napieralski, A.
Powiązania:
https://bibliotekanauki.pl/articles/397959.pdf
Data publikacji:
2012
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
EKG
Holter EKG
wpływ pogody na zdrowie
monitoring meteorologiczny
ECG
Holter monitoring
weather influence on health
weather monitoring
Opis:
This paper presents the concept of computing software platform that allows for simultaneous analysis of weather and Holter signals. The first part of this paper describes the weather station and the software platform that is currently being developed. The second part of the article presents examples of preliminary analysis that can be performed using the software platform.
Źródło:
International Journal of Microelectronics and Computer Science; 2012, 3, 4; 159-164
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ECG 3D mapping and its clinical applications, a preliminary study
Autorzy:
Adamusiak, T.
Zajdel, R.
Jacymirski, M.
Szczepaniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/333057.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG
odwzorowanie 3D
electrocardiography
3D mapping
Opis:
The inverse electrocardiography was under development for many years. In this novel approach one application was elaborated and described in this paper; with 3D real–time visualisation of ECG tracings on a PC. Using the electrocardiography data–stream from the chest leads, electrical excitation sequence was visualised — by the non–invasive technique, supported by the three–dimensional model of heart.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 8; II3-6
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja artefaktów EKG zarejestrowanych podczas monitorowania sygnału EMG
Identification of ECG Artifact Recorded During Monitoring of the EMG Signal
Autorzy:
Krawiecki, Z.
Szałkiewicz, S.
Hulewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/376054.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
sygnał bioelektryczny
sygnał EMG
identyfikacja zakłóceń
artefakt EKG
Opis:
W artykule opisane zostały wybrane zagadnienia związane z identyfikacją artefaktów EKG zarejestrowanych wraz z sygnałem bioelektrycznym z mięśni człowieka. Napisany został program do przetwarzania wyników pomiarów. Program wykorzystuje dane zapisane w pliku tekstowym. Algorytm aplikacji realizuje identyfikację składowych zespołu QRS. Wykonywane są operacje uśredniania sygnału w odpowiednio dobranych oknach czasowych. Na przykładzie wybranych plików z wynikami pomiarów przeprowadzone zostały testy działania algorytmu identyfikacji artefaktów i napisanej w środowisku Matlab aplikacji.
In the paper, the selected problems that concern the identification of ECG artifacts recorded in a bioelectrical signal of human muscles. A special program has been written to process the measurement results. The program uses the data that have been saved in a text file. The presented algorithm detects interferences related to the identification of the QRS component. Identification of the QRS components was performed by the algorithm. Signal averaging operations are realized in properly selected time windows. Using the selected files concerning the results, operation tests on the algorithm and Matlab application were realized.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 89; 229-238
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous recording and analysis of direct and indirect fetal electrocardiography
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333338.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG płodu
monitorowanie płodu
fetal electrocardiography
fetal monitoring
Opis:
Recording and analysis of fetal heart rate variability is still the most common method for detection of early symptoms of fetal hypoxia. However, fetal heart rate obtained via ultrasound describes only mechanical activity of fetus heart. Limitations of this technique have stimulated the development of fetal electrocardiography. It ensures more precise determination of fetal heart rate and, which is more important, enables assessment of the morphology of the fetal QRS complexes. In this paper two techniques of obtaining the fetal electrocardiogram are described and their comparative study is presented.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 8; MM111-118
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrocardiographic changes in pregnancy and postpartum period
Zmiany elektrokardiograficzne u kobiet ciężarnych i w okresie połogu
Autorzy:
Kandzia, Tomasz
Markiewicz-Łoskot, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/1036631.pdf
Data publikacji:
2016
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
pregnancy
postpartum
ecg
repolarization
ciąża
połóg
ekg
repolaryzacja
Opis:
Pregnancy and labor, though a physiological and natural time in a woman’s life, are associated with many changes to the woman’s body. The overall blood volume, cardiac output and heart rate of a pregnant woman differ significantly from pre-pregnancy time. This again has a significant effect on the electrical activity of the heart. Abnormal electric activity of the heart might be confused with an ongoing or commencing heart disease. Moreover, pregnancy, labour and especially the post partum period are also known to increase the risk of cardiac events including arrhythmia, myocardial infarction or even sudden cardiac death, especially in women with a present cardiac disease like LQTS (Long QT Syndrome). In order to reduce the occurrence of adverse cardiac events and enable their early detection and diagnosis, there is a need for a more thorough understanding of electrocardiographic changes occurring during pregnancy. Unfortunately, data regarding changes of the electric activity of the heart during pregnancy are scarce. The aim of this work is to give an outline on the electric activity changes of the heart of a pregnant woman. The available data confirm that intense changes in the cardiovascular system caused by pregnancy strongly affect the electrical activity of the heart.
Ciąża i poród, choć należą do fizjologicznego i naturalnego czasu w życiu kobiety, wiążą się z wieloma zmianami w jej organizmie. Całkowita objętość krwi, rzut serca i tętno u kobiet w ciąży znacznie odbiegają od wartości przedciążowych. Zmiany te mają znaczący wpływ na aktywność elektryczną serca. Zmieniona aktywność elektryczna serca może być mylona z trwającą lub nowo powstałą chorobą serca. Ponadto w okresie ciąży, porodu, a również połogu w sposób istotny zwiększa się ryzyko zdarzeń sercowych, w tym zaburzeń rytmu, zawału serca lub nawet nagłej śmierci sercowej, zwłaszcza u kobiet z chorobą serca w wywiadzie, takich jak LQTS (zespół wydłużonego odcinka QT). W celu zmniejszenia występowania niepożądanych zdarzeń sercowych oraz umożliwienia ich wcześniejszego wykrywania i diagnostyki istnieje potrzeba bardziej dogłębnego zrozumienia zmian elektrokardiograficznych zachodzących w okresie ciąży. Niestety, dane dotyczące zmian elektrokardiograficznych w ciąży są nieliczne. Celem naszej pracy poglądowej jest przedstawienie zarysu zmian elektrycznej aktywności serca u kobiety ciężarnej. Dostępne wyniki badań dowodzą, że intensywne zmiany w układzie krążenia spowodowane ciążą silnie wpływają na aktywność elektryczną serca.
Źródło:
Annales Academiae Medicae Silesiensis; 2016, 70; 9-14
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power supply and signal filtering for 24-hour ECG
Autorzy:
Tomala, R.
Marciniak, P.
Kotas, R.
Wenerski, M.
Napieralski, A.
Powiązania:
https://bibliotekanauki.pl/articles/398077.pdf
Data publikacji:
2011
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
Holter EKG
elektrokardiografia
EKG
linia izoelektryczna
zakłócenia mięśniowe
interferencje
Holter monitoring system
electrocardiograph
ECG
baseline wandering
muscle noise
power line interference
Opis:
The goal of this research is to present signals filtering for the high resolution Hotter monitoring system. The first part of this paper concentrates on working of human heart and description of architecture of biopotentials recorder. This part also includes proper amplification and filtration of interferences of bioelectric signals. The second part of this research presents practical realization of Holter monitoring system. Special attention is put on proper selection of components of the recorder and joining them into optimal structure.
Źródło:
International Journal of Microelectronics and Computer Science; 2011, 2, 1; 28-34
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of defibrillation treatment on some electrical parameters and application safety of ECG electrodes
Autorzy:
Ochocki, M.
Latos, S.
Powiązania:
https://bibliotekanauki.pl/articles/333268.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG
elektrody
defibrylacja
impedancja
bezpieczeństwo
ECG
electrodes
defibrillation
impedance
safety
Opis:
The subject of examination was mainly the determination of safety of available ECG electrodes use in conditions of defibrillation treatment in monitored patients. The electrodes of four European producers used in healthcare have been tested. For reason of periods of electrodes obtaining and their physical condition, the examinations have comprised four selected years and 7 types of electrodes. For testing needs, the electrodes were glued into pairs, in gel-to-gel mode. Testing was based on requirements of globally used American ANSI⁄AAMI EC 12:2000⁄(R)2010 standard for disposable ECG electrodes. For the electrodes pairs tested, determined was the influence of fourfold defibrillation release on polarization potential and their impedance measured with the current of 10 Hz frequency. It has been generally found that in result of fourfold exposition to defibrillating pulse the drop of impedance occurred in all tested, electrode pairs. For each electrodes series, mean value of this drop falls into interval of 10,8% to 57%. It was also pointed out that the ECG electrodes examined, while complying to requirements of the standard, allow the operator to perform the defibrillation procedure safely, including the possibility to fast evaluate the defibrillation result basing on ECG waveform recorded. Such general estimation of safety level of the available European ECG electrodes may be used as some reference in today very diversified market as to provenience end quality of products.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 133-139
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assesment of low-frequency response of ECG recorders in relation to international requirements
Autorzy:
Gibiński, P.
Owczarek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333784.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
analiza EKG
międzynarodowe wymogi
ECG analysis
ST-segment
international requirements
Opis:
Electrocardiography (ECG) is commonly used non-invasive procedure for recording electrical activity of the heart. It is a powerful clinical non-invasive tool for proper diagnosis and therapy of cardiac abnormalities. Thus, accurate reproduction of the ECG is required especially if diagnosis making process is supported by automatic measurements and their interpretation. The paper presents an assessment of lowf-requency response of selected ECG recorders in relation to international requirements. Four recorders have been selected and tested according to IEC draft 62D: 60601-2-51/Ed.1 and the results have been discussed.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT63-72
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristic points detection in ECG signal using Bayesian learning and fuzzy system
Autorzy:
Momot, M.
Momot, A.
Powiązania:
https://bibliotekanauki.pl/articles/333840.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
sygnał EKG
systemy rozmyte
ECG signal
fuzzy systems
bayesian learning
Opis:
Characteristic points detection such as beginnings and ends of P-wave, T-wave or QRS complex is one of primary aims in automated analysis of ECG signal. The paper presents one possible approach based on Bayesian inference to design of kernel based classifier. The classification function is constructed using the probability distribution function of standard normal distribution and independent Gaussian random variables. The parameters of such variables are computed using iterative Expectation-Maximization algorithm. This approach is used to calculate parameters of classification function to modelling Takagi-Sugeno-Kang fuzzy systems. Numerical experiment of characteristic points detection in ECG signal using CTS database is also presented.
Źródło:
Journal of Medical Informatics & Technologies; 2007, 11; 171-176
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody rozpoznawania sygnałów EKG w celu określenia ekspozycji na pole magnetyczne
Autorzy:
Libal, U.
Sztafrowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/1190073.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
rozpoznawanie sygnałów
EKG
pole magnatyczne
pattern recognition
electrocardiogram
magnetic field
Opis:
Wpływ pola magnetycznego na organizm ludzki może być zarówno pozytywny, jak i negatywny. Możliwe, że w przyszłości, gdy zostanie doprecyzowane prawo dotyczące bezpiecznej ekspozycji na pole magnetyczne, wykrywanie post fatum przekroczeń będzie narzędziem przyczyniającym się do ochrony pracowników na stanowiskach pracy. Artykuł przedstawia zastosowanie algorytmów rozpoznawania wzorców (takich jak klasyfikator Bayesowski, czy algorytm k-Nearest Neighbors) dla sygnałów EKG w celu określenia, czy ochotnik został poddany działaniu pola magnetycznego. Rozpatrywany jest dwuklasowy problem klasyfikacji nadzorowanej. W pierwszym etapie klasyfikator jest uczony na podstawie ciągu uczącego, zawierającego sygnały EKG zarejestrowane przed (klasa 1) i po (klasa 2) godzinnej ekspozycji ochotnika na pole magnetyczne. W etapie drugim nauczony klasyfikator sam decyduje o wyborze klasy dla nowego sygnału EKG. Porównanie wyników klasyfikacji ze znanym rzeczywistym faktem narażenia lub brakiem narażenia na pole magnetyczne pozwala wyznaczyć jakość klasyfikatora. Jakość klasyfikatora jest mierzona ryzykiem popełnienia przez klasyfikator błędu. Niska wartość ryzyka oznacza, że taki klasyfikator może być używany do detekcji wystąpienia narażenia na pole magnetyczne na podstawie analizy sygnału EKG.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2013, 1, 1; 32--35
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrocardiogram generation software for testing of parameter extraction algorithms
Autorzy:
Maciejewski, Marcin
Maciejewska, Barbara
Karpiński, Robert
Krakowski, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/1837776.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
ECG
software
algorithm testing
heart
EKG
oprogramowanie
testowanie algorytmów
serce
Opis:
Fast and automated ECG diagnosis is of great benefit for treatment of cardi-ovascular and other conditions. The algorithms used to extract parameters need to be precise, robust and efficient. Appropriate training and testing methods for such algorithms need to be implemented for optimal results. This paper presents a software solution for computer ECG generation and a simplified concept of testing process. All the parameters of the resulting generated signal can be tweaked and set properly. Such software can also be beneficial for training and educational use.
Źródło:
Applied Computer Science; 2020, 16, 4; 37-47
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ECG signal analysis for detection BPM
Wykrywanie HR na podstawie sygnału EKG
Autorzy:
Śmigiel, S.
Ledziński, D.
Powiązania:
https://bibliotekanauki.pl/articles/389822.pdf
Data publikacji:
2014
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
ECG analysis
algorithm
R-waves
BPM
EKG
algorytm
załamek R
HR
Opis:
The methodology in this article is focused on the development intelligent algorithms in the area of biomedical engineering, or more precisely, on the biomedical signal. The purpose of these activities is generally counteraction to occurring the problem of diagnosing cardiac diseases based on the ECG signal. This paper proposes various algorithms to detect the BPM, which can be used for diagnosis of cardiovascular abnormalities. These algorithms detects the R-peaks in signal ECG and on their basis computes the BPM. Proposed solutions allow to select three algorithms to determine R-peaks. As part of this method have been used function of threshold, the derivative signal, and the slider window.
Przedstawiona w pracy metodologia badawcza koncentruje się na rozwoju inteligentnych algorytmów w obszarze inżynierii biomedycznej, a ściślej w zakresie przetwarzania sygnałów biomedycznych. Celem realizowanych w pracy algorytmów jest ogólnie występujący problem diagnozowania chorób serca, w oparciu o zapis EKG. Niniejszy dokument prezentuje różnego rodzaju algorytmy wykrywające wartości HR, świadczące o częstotliwości pracy serca, które mogą stanowić oparcie dla lekarzy w diagnozowaniu zaburzeń sercowonaczyniowych. Analizowane algorytmy wykrywają załamki R z zapisu EKG, aby w dalszym etapie obliczyć HR. Proponowane przez autorów rozwiązania umożliwiają wybór jednej z trzech omówionych metod. W każdej z nich został zastosowany inny algorytm wyznaczania załamków R. Wprowadzono m.in. funkcję progu, wyznaczanie pochodnej sygnału oraz okno przesuwne.
Źródło:
Zeszyty Naukowe. Telekomunikacja i Elektronika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy; 2014, 18; 23-31
1899-0088
Pojawia się w:
Zeszyty Naukowe. Telekomunikacja i Elektronika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparing methods of ECG respiration signals derivation based on measuring the amplitude of QRS complexes
Autorzy:
Kikta, A.
Augustyniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/333821.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG
sygnał oddechowy
wykrywanie bezdechu
ECG
EDR
respiratory signal
apnea detection
Opis:
This paper presents the study of algorithms for derivation of respiration waveform from the electrocardiogram. The problem has considerable clinical impact, because the heart rate and respiration are both driven by the central nervous system, and commonly used low-cost Holter recording may be used for efficient detection of breath disturbances (e.g. apnea). Three methods based on: heart rate, heart position and lung resistance influencing the ECG amplitude were compared in our research. Among 18 volunteers breathing at a controlled frequency all implemented algorithms show acceptable sensitivity of order of 97% in slow breathing phases detection. In fast breathing the sensitivity is reduced to 90%, since the heart beats are too sparse with regard of respiration waveform.
Źródło:
Journal of Medical Informatics & Technologies; 2007, 11; 155-163
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using the dsPIC microcontroller for ECG QRS complex interpretation
Badanie i interpretacja zespołu ECG-QRS w układzie mikrokontrolera dsPIC
Autorzy:
Kurtynik, P.
Borowik, B.
Powiązania:
https://bibliotekanauki.pl/articles/157362.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikrokontroler
PIC micro
QRS
EKG
DSP
cardiac signal
microcontroller
ECG
PICmicro
Opis:
The paper provides a QRS descriptive analysis of the ECG plots obtained from a Digital Signal Processing circuitry. In the considered here project there has been used a high performance DSP 16-bit microcontroller of the dsPIC33F family. Its capabilities comprise of digital signal filtering and processing. The authors have attempted to provide here a descriptive analysis of the ECG tracing, especially of the QRS complex. At the beginning the analog data from ECG electrodes has been converted into a digital form for further DSP processing. In the next step data has been sent through the SPI bus to the mass storage device, such as the removable Flash-based media card for further analysis. For a practical reason a versatile SD card has been used.
W pracy przedstawiono zastosowanie układu przetwarzania sygnałów do badania zespołu QRS, przy interpretacji danych EKG. Zespół QRS odzwierciedla elektryczno-impulsową aktywność serca. Reprezentuje on pobudzenie, czyli depolaryzację komór serca. Ma on także szerokie widmo częstotliwości. Celowe staje się tu zastosowanie procesora sygnałowego DSP, pozwalającego na przetwarzanie sygnałów. Charakterystyka i kształt zespołu QRS dają najwięcej informacji o pracy serca. Analizę QRS w dziedzinie częstotliwości przeprowadza się za pomocą specyfikowanego modułu mikrokontrolera: DSP Engine do przetwarzania sygnałów, w którym wykorzystywany jest specjalny zestaw instrukcji DSP Instruction Set. Znajduje tu zastosowanie dyskretne przekształcenie Fouriera DFT. Do analizy zespołu QRS wykorzystana jest także funkcja autokorelacji. Przy analizie częstotliwości sygnału wykorzystywany jest kolejno fragment QRS w oparciu o funkcję okna, znajdującą się w programie.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 3, 3; 259-261
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie transformaty falkowej do detekcji rytmu zatokowego w sygnale EKG
Using wavelet transform for detection of sinus rhythm in ECG signal
Autorzy:
Wilk, B.
Powiązania:
https://bibliotekanauki.pl/articles/157996.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
detekcja załamków EKG
transformata falkowa
detection of ECG waves
wavelet transform
Opis:
W artykule omówiono podstawowe zasady rozpoznawania rytmu zatoko-wego w sygnale EKG. Zaprezentowano przykłady zastosowania transformaty falkowej (ang. wavelet transform, WT) do wyznaczania lokalizacji czasowej załamków P i R. Parametry wspomnianych załamków oraz relacje czasowe zachodzące miedzy nimi są wykorzystywane do automa-tycznej detekcji (w trybie off-line) rytmu zatokowego serca.
In this article, basic principles applied to recognition of the sinus rhythm in ECG signal are described. Examples of using the wavelet transform for determination of P and R waves localization are presented. Parameters of the mentioned waves and time relations between them are using for automatic off-line detection of the sinus rhythm.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 38-40
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimizing the machine description of electrocardiogram
Autorzy:
Augustyniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/333326.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
interpretacja EKG
przenośne urządzenie medyczne
telemedycyna
electrocardiogram interpretation
wearable medical devices
telemedicine
Opis:
The electrocardiogram is a digital record of effective action potentials of heart muscle fibres, thus it contains an important information about the heart function. Unfortunately, the signal theory-based description of the ECG contents is not efficient in extracting these data, and the practical interpretation software is mostly based on heuristic statements. This conclusion was a motivation for our research on the expert-like machine reasoning based on ECG perception analysis, physiology-driven feature extraction and fuzzy logic. This paper highlights the aspect of optimal description of an electrocardiogram contents in a digital record.
Źródło:
Journal of Medical Informatics & Technologies; 2004, 8; MM41-48
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Empirical Bayesian averaging method and its application to noise reduction in ECG signal
Autorzy:
Momot, A.
Momot, M.
Łęski, J.
Powiązania:
https://bibliotekanauki.pl/articles/333575.pdf
Data publikacji:
2006
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
sygnał EKG
średnia ważona
wnioskowanie bayesowskie
ECG signal
weighted averaging
Bayesian inference
Opis:
An electrocardiogram (ECG) is the prime tool in non-invasive cardiac electrophysiology and has a prime function in the screening and diagnosis of cardiovascular diseases. However one of the greatest problems is that usually recording an electrical activity of the heart is performed in the presence of noise. The paper presents empirical Bayesian approach to problem of signal averaging which is commonly used to extract a useful signal distorted by a noise. The averaging is especially useful for biomedical signal such as ECG signal, where the spectra of the signal and noise significantly overlap. In reality the variability of noise can be observed, with power from cycle to cycle, which is motivation for weighted averaging methods usage. It is demonstrated that by exploiting a probabilistic Bayesian learning framework, it can be derived accurate prediction models offering significant additional advantage, namely automatic estimation of 'nuisance' parameters. Performance of the new method is experimentally compared to the traditional averaging by using arithmetic mean and weighted averaging method based on criterion function minimization.
Źródło:
Journal of Medical Informatics & Technologies; 2006, 10; 93-101
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Fuzzy Relevance Vector Machine and its application to noise reduction in ECG signal
Autorzy:
Momot, A.
Momot, M.
Łęski, J.
Powiązania:
https://bibliotekanauki.pl/articles/333828.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
systemy rozmyte
wnioskowanie bayesowskie
sygnał EKG
fuzzy systems
Bayesian inference
ECG signal
Opis:
The paper presents new method called the Fuzzy Relevance Vector Machine (FRVM), a modification of the relevance vector machine, introduced by M. Tipping, applied to learning Takagi-Sugeno-Kang (TSK) fuzzy system. Moreover it describes application of the FRVM to noise reduction in ECG signal. The results of the process are compared to those obtained using both Least Squares method for learning output functions in TSK rules and commonly used method using a low-pass moving average filter.
Źródło:
Journal of Medical Informatics & Technologies; 2005, 9; 99-105
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies