Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "camera calibration" wg kryterium: Temat


Tytuł:
A new method to estimate dimensions of vehicle using a single camera
Autorzy:
Bazan, M.
Janiczek, T.
Halawa, K.
Wykrzykowski, A.
Łabuda, P.
Powiązania:
https://bibliotekanauki.pl/articles/393575.pdf
Data publikacji:
2017
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
vehicle dimensions estimation
single camera vehicle sizes estimation
calibration
szacowanie wielkości pojazdu
kalibracja
Opis:
The capability of a telematic vision system of estimating dimensions of vehicles is used for such tasks as vehicle classification or preselection of vehicles that violate local vehicle size limitations. Also in some European countries dimensions of heavy vehicles must obey some global regulations. Furthermore, vehicle size estimation allows us to determine the structure of traffic and can be very useful for advanced traffic flow control. Many existing Intelligent Transportation Systems consist of a large number of video cameras located in various places e.g., the ITS in Wrocław uses more than 1400 cameras. In this paper we propose a new method developed by the ArsNumerica Group and CyberTech Scientific Circle for the precise estimation of vehicle sizes using a single camera. The method does not require the entering of measurements such as the distance between lane lines or the height of the camera above the roadway. Only one vehicle’s dimensions are used for calibration. The proposed method is easy to implement and may be applied with the OpenCV library which is free both for academic and commercial use. The method is tested on real-world video streams. The obtained results are shown and analyzed in the paper.
Źródło:
Archives of Transport System Telematics; 2017, 10, 3; 3-7
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A stereovision system for three-dimensional measurements of machines
Autorzy:
Grudziński, Marek
Marchewka, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/135398.pdf
Data publikacji:
2019
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
stereovision system
machine vision
camera tracking
camera calibration
calibration pattern
3D reconstruction
Opis:
The modern manufacturing or transportation machines that are used in industrial processes require continuous supervision in certain circumstances and even manual control by a human. Despite the fact the machines are more and more reliable and accurate than they used to be there is still the need for manual and time-consuming programming and safety control, especially when the external conditions change. For the operation of large machines, where the risk of damage and even disaster exists, an additional supervisory system based on vision devices could be utilized. The vision systems are commonly used in a range of simple 2D detection as well as very precise 3D reconstruction. The stereovision systems could be applied for unusual operations, especially in terms of safety and collision avoidance, such as crane observations while transporting a heavy load, robot and CNC machine preparation and normal operation. Through the use of optical devices the observed objects could be quickly positioned. In this research a test bench for stereovision reconstruction for the example of a robotic arm has been presented. The calibration procedures have been explained and accuracy tests in a large measuring volume were performed. Finally the possibilities of the applications and the utilization of such a system have been assessed.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2019, 58 (130); 16-23
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy analysis of automatic distortion correction
Ocena dokładności automatycznej korekcji dystorsji
Autorzy:
Kolecki, J.
Rzonca, A.
Powiązania:
https://bibliotekanauki.pl/articles/145565.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
camera calibration
radial distortion
disortion correction
accuracy analysis
bundle adjustment
korekcja zniekształceń
analiza dokładności
pomiar fotogrametryczny
Opis:
The paper addresses the problem of the automatic distortion removal from images acquired with non-metric SLR camera equipped with prime lenses. From the photogrammetric point of view the following question arises: is the accuracy of distortion control data provided by the manufacturer for a certain lens model (not item) sufficient in order to achieve demanded accuracy? In order to obtain the reliable answer to the aforementioned problem the two kinds of tests were carried out for three lens models. Firstly the multi-variant camera calibration was conducted using the software providing full accuracy analysis. Secondly the accuracy analysis using check points took place. The check points were measured in the images resampled based on estimated distortion model or in distortion-free images simply acquired in the automatic distortion removal mode. The extensive conclusions regarding application of each calibration approach in practice are given. Finally the rules of applying automatic distortion removal in photogrammetric measurements are suggested.
Publikacja ma na celu przedstawienie wyników automatycznego usuwania dystorsji dla niemetrycznej kamery z obiektywem stałoogniskowym. Z punktu widzenia fotogrametrii pojawia się zasadnicze pytanie, czy dokładność określenia dystorsji dla danego typu obiektywu (a nie egzemplarza) jest wystarczająca, żeby otrzymać oczekiwane dokładności pomiaru fotogrametrycznego. W tym celu wykonano dwa rodzaje obliczeń kontrolnych. Pierwsze obliczenia to kalibracja kamery w wariantach zapewniających szeroką dyskusję wyników, wykonana w oprogramowaniu zapewniającym podanie pełnej analizy dokładności. Dodatkowo każdy wariant został sprawdzony poprzez kalibrację kontrolną, którą policzono na podstawie pomiaru zdjęć z fizycznie usuniętym wpływem dystorsji. Drugi etap obliczeń – analiza dokładności – polegał na wykonaniu pomiarów sprawdzających punktów kontrolowanych na zdjęciach dla wszystkich 3 zestawów przyjętych lub obliczonych elementów orientacji wewnętrznej oraz dystorsji usuniętej automatycznie lub programem, na podstawie wyników kalibracji. W publikacji zamieszczono obszerny komentarz dotyczący praktycznych aspektów stosowania każdej z tych metod kalibracji. Wniosek ostateczny podaje zasady stosowania wyników automatycznej redukcji dystorsji w zastosowaniach fotogrametrycznych.
Źródło:
Geodesy and Cartography; 2015, 64, 1; 3-14
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy kalibracji stereoskopowego układu kamer i rekonstrukcji sceny trójwymiarowej na podstawie obrazów termowizyjnych
Calibration methods for stereoscopic cameras used in 3D scene reconstruction
Autorzy:
Rzeszotarski, D.
Powiązania:
https://bibliotekanauki.pl/articles/154660.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stereowizja
kalibracja kamer
trójwymiarowa rekonstrukcja
obrazy termowizyjne
stereovision
camera calibration
3D reconstruction
thermal images
Opis:
W niniejszej pracy pojęcie trójwymiarowej rekonstrukcji sceny na podstawie obrazów termowizyjnych jest rozumiane, jako przypisanie każdemu punktowi obrazu termowizyjnego współrzędnych przestrzennych. Kalibracja układu kamery (lub kamer) jest ważnym elementem takiej rekonstrukcji. W artykule opisano algorytmy do kalibracji kamer pod kątem ich zastosowania do trójwymiarowej rekonstrukcji sceny termowizyjnej. Na tle istniejących rozwiązań w omawianej tematyce opisano podejście zaproponowane przez autora. Algorytmy napisano w języku C++ oraz poddano weryfikacji, której wyniki opisano w końcowej części pracy.
In this paper reconstruction of 3D scene refers to assigning 3D coordinates to each pixel of a thermal image. Calibration of cameras is a crucial element of such a system. There is presented classification and review of camera calibration techniques in the paper. The first perspective model of a single camera is given (Fig. 1) and the basics regarding 3D reconstruction by means of a stereoscopic set of cameras are provided (Fig. 2). Classification of 3D scene reconstruction techniques according to calibration algorithms is summed up in Tab. 1. The calibration algorithm of a single camera by means of a special board is described in Section 5. Next, the more detailed description of the algorithms providing extrinsic parameters i.e. the rotation matrix and translation vector between two cameras or two different positions of the same camera is given. Finally, a robust calibration technique proposed by the author is outlined. The stereovision set integrated with a thermal camera used as a test bed for the implemented calibration algorithms is shown in Fig. 4. The obtained results of calibration and reconstruction are presented in Tabs. 3 and 4. The reconstructed object is shown in Fig. 5. According to Tab. 4, the best reconstruction results are obtained by means of a stereovision set consisting of two visual cameras calibrated by means of a classical calibration board (Fig. 3). In the case of a single moving thermographic camera calibrated by means of the method proposed by the author, the obtained recon-struction results are worse; the reconstruction error is about 5 mm, while the distances between the reconstructed points are 300mm (Fig. 5).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1138-1141
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis on the dynamic deformations of the images from digital film sequences
Badania zniekształceń dynamicznych obrazów pochodzących z cyfrowych sekwencji filmowych
Autorzy:
Markowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/145385.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
image sequences
digital video camera
internal geometry
non-metric camera
camera calibration
sekwencje obrazów
kamera cyfrowa
kalibracja kamery
Opis:
Image sequences, in particular digital video sequences, are characterised by the features which result in their high potential as measurement data. However, as early as at the stage of visual assessment of digital film images, originating, in particular, from amateur cameras, occurrence of some deformations may be observed, which may highly influence the results of measurements performed using these images; such deformations differ from deformations occurred in the case of static photographic images. It results both, by the method of image recording, using an electronic shutter and interlaced or progressive scanning, as well as the method of file recording and compression. It is worth to notice the systematic nature of such deformations, which highly depend on mutual motions of a camera and recorded objects. The objective of presented research works was to develop the mathematical description of image deformations, as a function of motion parameters. This would allow for adaptation of the camera calibration process to the demands of sequential imaging, as well as for modification of algorithms of measurements using self-calibration, and, as a result, minimisation of deformations. Another objective was to analyse the influence of deformations, typical for digital film images, on the results of measurements performed using these images, by means of series of experiments, which were based on multiple calibration of static and a moving camera, also with the use of a spatial test field. The first part was made by developing formulas based on some geometric relations, using some simplifications. On the stage of experimental research a certain degree of compatibility of experimental results and theoretical assumptions were confirmed.
Zobrazowania sekwencyjne, a w szczególności sekwencje filmowe, posiadają cechy, dzięki którym mogą mieć duży potencjał pomiarowy. Należą do nich między innymi systematyka i stosunkowo duża częstotliwość obrazowania, skutkujące dużą liczbą obserwacji oraz podobieństwem sąsiednich obrazów (co ma znaczenie przy automatyzacji pomiarów), a ponadto zmniejszony wkład pracy operatora kamery, możliwość pozyskiwania i przetwarzania w czasie rzeczywistym oraz ogromna i nadal zwiększająca się dostępność zobrazowań. Jednak już na etapie oceny wzrokowej cyfrowych zobrazowań filmowych, zwłaszcza pochodzących z kamer określanych powszechnie jako amatorskie, zauważyć można występowanie pewnych zniekształceń, które mogą mieć znaczący wpływ na wyniki pomiarów. Jest to spowodowane zarówno sposobem rejestracji, z wykorzystaniem migawki elektronicznej i przeplotowego lub progresywnego skanowania, jak i metodami zapisu i kompresji plików. Warto zauważyć, iż są to w dużym stopniu deformacje systematyczne, uzależnione od wzajemnego ruchu kamery i badanego obiektu. Celem opisanych w artykule badań była próba opisu, typowych dla cyfrowych zobrazowań filmowych, zniekształceń dynamicznych, w funkcji parametrów ruchu kamery względem obiektu, jak również próba zbadania rozkładu deformacji poprzez wykonane w odpowiedni sposób wielokrotne kalibracje kamery, w celu porównania otrzymanych wartości z rozważaniami teoretycznymi. Pierwsza część została wykonana, poprzez wyprowadzenie w oparciu o relacje geometryczne, wzorów, opisujących deformacje dynamiczne obrazu, w funkcji współrzędnych tłowych, prędkości liniowej lub kątowej, czasu rejestracji pojedynczej linii obrazu oraz odległości obrazowej i odległości kamery od obiektu. Część druga, eksperymentalna, obejmowała z kolei analizy rozkładu zniekształceń dynamicznych dla kilku przykładowych sekwencji, zarejestrowanych w trakcie obrotów kamery wokół poszczególnych osi układu współrzędnych. Analizując wyniki eksperymentów, potwierdzono pewną zgodność występujących rzeczywistych zniekształceń z przewidywaniami, które pojawiły się na etapie rozważań teoretycznych. Niestety nie udało się przeprowadzić konkretnych analiz liczbowych, ponieważ na tym etapie nie opracowano jeszcze metody wyznaczenia czasu rejestracji pojedynczej linii obrazu, co uniemożliwiło oszacowanie wartości teoretycznych deformacji.
Źródło:
Geodesy and Cartography; 2015, 64, 1; 43-64
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie cyfrowych aparatów fotograficznych dla zastosowań fotogrametrycznych
An investigation of digital photographic cameras for the close-range photogrammetry
Autorzy:
Tokarczyk, R.
Boroń, A.
Powiązania:
https://bibliotekanauki.pl/articles/130044.pdf
Data publikacji:
2000
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
cyfrowy aparat fotograficzny
fotogrametria
kalibracja
digital compact camera
photogrammetry
calibration
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2000, 10; 63-1-63-10
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie potencjału pomiarowego aparatu cyfrowego typu SLR Kodak DCS Pro 14n (13.5 MP)
Evaluation of the measuring potential of Kodak DCS Pro 14n (13.5 MP) SLR digital camera
Autorzy:
Sawicki, P.
Ostrowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/129958.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
lustrzanka cyfrowa
dystorsja sygnału
samokalibracja
metoda wiązek
digital SLR camera
signal distortion
self-calibration
bundle adjustment
Opis:
Badanie jakości radiometrycznej sygnału i samokalibrację fotogrametryczną przeprowadzono dla lustrzanki cyfrowej Kodak DCS Pro 14n wyposażonej w sensor CMOS (format 36×24 mm, rozdzielczość 4500×3000). Ocenę poziomu szumów i dystorsji sygnału przetwornika CMOS IBIS4-14000 (FillFactory NV, Belgia) wykonano w autorskim programie "Image Analysis" napisanym w języku Delphi 7. Program oblicza średnia wartość poziomu szarości, wariancje oraz odchylenie standardowe dla każdego piksela w zdefiniowanych obszarach zainteresowania sekwencji obrazów. Na podstawie analizy sekwencji 30 obrazów stwierdzono, _e obrazy rejestrowane aparatem Kodak DCS Pro 14n charakteryzują się niskim poziomem szumów i wysoka jakością układu przetwarzającego dane. Dla jasności I średnie odchylenie standardowe wyniosło SdtDev = 1.5 (kanał R: SdtDev = 1.7, kanał G: SdtDev = 1.6, kanał B: SdtDev = 2.1). Samokalibracje on-the-job z dodatkowymi parametrami modelującymi błędy systematyczne obrazu: A1 , A2 , B1 , B2 , C1 , C2 , łącznie z wyznaczeniem współrzędnych 3D dla ca 110 sygnalizowanych punktów (30 punktów kodowanych, kod 12 bit) pola testowego, przeprowadzono programem AICON 3D Studio firmy AICON Systems GmbH, Niemcy. Siec zdjęć tworzyła konfiguracja 11 zdjęć zbieżnych wykonanych z odległości ca YF = 5 m. Wszystkie punkty na zdjęciach cyfrowych zostały pomierzone w pełni automatycznie. Średnia wartość Sigma 0 po wyrównaniu metoda wiązek wyniosła _0 = ±0.055 piksela. Podstawowe elementy orientacji wewnętrznej: cK, x¢ 0 , y¢ 0 wyznaczone zostały z dokładnością ±0.2 piksela. Średnie odchylenie standardowe wyznaczonych współrzędnych wyniosły odpowiednio: SXY = ±0.03 mm, SZ = ±0.04 mm. W prezentowanej aplikacji bliskiego zasięgu przy zastosowaniu profesjonalnej lustrzanki cyfrowej Kodak DCS Pro 14n otrzymano względną dokładność opracowania analitycznego rzędu ca 1: 150 000.
The study on the radiometric signal quality and the photogrammetric self-calibration was performed for the Kodak DCS Pro 14n SLR digital camera with the CMOS sensor (format size of 36×24 mm, full resolution of 4500×3000). The examination of noise level and the signal distortion in the CMOS IBIS4-14000 (Fill Factory NV, Belgium) converter was determined in the "Image Analysis" authors’ software, which was written with the Delphi 7 programming tools. The program calculates mean grey level value, variance and standard deviation for each pixel in the defined areas of interest in the image sequences. Based on the analysis of 30 image sequences, it was found that low noise level and high quality of data processing module were characteristic for the Kodak DCS Pro 14n camera. In the brightness channel I, the mean standard deviation amounted to SdtDev = 1.5 (channel R: SdtDev = 1.7, channel G: SdtDev = 1.6, channel B: SdtDev = 2.1). The on-the-job self-calibration with additional digital imaging systematic errors modelling parameters: A1, A2, B1, B2 , C1, C2 and the calculation with ca 110 signalised points 3D coordinates (30 coded points, 12 bit code) on a test field, was determined in the AICON 3D Studio program (AICON Systems GmbH, Germany). The digital image network was created by the configuration of eleven convergent photos registered from the distance of ca YF = 5 m. All points in digital images were measured completely automatically. The Sigma 0 mean value after the combined bundle adjustment amounted to _0 = ±0.055 pxl. Basic parameters of interior orientation: cK, x¢ 0 , y¢ 0 were determined with the accuracy of ±0.2 pxl. The mean standard deviation of calculated coordinates amounted to: SXY = ±0.03 mm, SZ = ±0.04 mm. In the presented close range application, when the Kodak DCS Pro 14n SLR digital camera was used, a relative accuracy of 3D coordinates analytical estimation of 1: 150 000 in the object space was achieved.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2007, 17b; 729-738
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu filtracji cyfrowej na dokładność rozwiązania metodą wiązek sieci zdjęć bliskiego zasięgu
Assessment of the influence of digital filtering on the accuracy of close range bundle blockadjustment
Autorzy:
Sawicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/129845.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
lustrzanka cyfrowa
obraz cyfrowy
filtr cyfrowy
pomiar automatyczny
metoda wiązek
kalibracja równoczesna
DSLR camera
digital image
digital filter
automatic measurement
bundle adjustment
self-calibration
Opis:
Zastosowanie filtracji cyfrowej umożliwia korekcję wpływu nieostrości (rozmycia) oraz wyeliminowanie szumów na obrazach cyfrowych. W pracy badano wpływ 6. liniowych filtrów górnoprzepustowych (high-pass filters), wyostrzających obrazy rozmyte, oraz 5. filtrów liniowych dolnoprzepustowych (low-pass filters) i nieliniowego filtru medianowego, służących do eliminacji szumów, na dokładność pomiaru i rozwiązania sieci zdjęć bliskiego zasięgu. Badania przeprowadzono na 11. zdjęciach cyfrowych (4500x3000) pola testowego (220 punktów sygnalizowanych, w tym 65 punktów kodowych), z których wygenerowane zostały obrazy JPG nieostre (rozmycie gaussowskie, promień r = 2, r = 3 piksele) i obarczone szumem (gaussowski losowy, poziom = 25, gęstość= 50). W systemie AICON 3D Studio wykonano automatyczny pomiar punktów metodą ważonego środka ciężkości (Center Weighted Metod) oraz rozwiązanie terratriangulacji metodą wiązek, łącznie z kalibracją lustrzanki cyfrowej. Stwierdzono, że filtracja górnoprzepustowa obrazów nieostrych (rozmycie r = 2) jest niezbędna przy pomiarze punktów strukturalnych metodą ważonego środka ciężkości. W przypadku pomiaru obrazów silnie rozmytych (r = 3) jedynym skutecznym filtrem górnoprzepustowym, który umożliwia pomiar punktów, jest laplasjan gaussowski (maska 5×5 pikseli). Filtracja dolnoprzepustowa i medianowa obrazów zaszumionych nie wpływa na dokładność pomiaru oraz zmianę wartości wyznaczanych parametrów. Metoda ważonego środka ciężkości działa skutecznie przy pomiarze sygnalizowanych punktów na nieznacznie rozmytych obrazach cyfrowych bliskiego zasięgu oraz jest odporna na występowanie szumów losowych. W analizowanych wariantach obliczeń otrzymano dokładności: Sigma 0 = 0.07 piksela (p’HV= 7.9 μm), średniokwadratowe poprawki do współrzędnych tłowych RMS Vx’ = 0.05, RMS Vy’ = 0.06 piksela, oraz średniokwadratowe błędy współrzędnych wyznaczonych w układzie obiektu RMS SX = 0.05 mm, RMS SY = 0.1 mm, RMS SZ = 0.04 mm.
Random and systematic radiometric distortion in the images sequence is a common issue in digital photogrammetric close range applications. A digital image filtering enables correction of blur and elimination of noise on digital images. The paper analyses the influence of digital filtering of blurred and noisy close-range images on the subpixel accuracy of signalized points measurement and accuracy block bundle adjustment. Blurred (out of focus) images were processed with 6 linear high-pass filters, whereas 5 linear low-pass filters and 1 nonlinear median filter were applied for noisy images. The photogrammetric measurement was conducted on test field in Institute of Photogrammetry and Remote Sensing, Dresden University of Technology. The test field consisted of the total of 220 signalized, retro-reflective points (65 coded points, 14 bit code). The test field was registered on eleven convergent and normal color photos from the distance of ca YF = 5 m using digital SLR Kodak DCS Pro 14n (resolution 4500x3000) camera. Adobe Photoshop CS6 and Corel PHOTO-PAINT X6software were used for generation of blurred images (Gaussian blur, radius r = 2 and radius r = 3) and noisy images (random Gaussian noise, level = 25, density = 50). The fully automatic points measurement on the digital images using center weighted method, the bundle adjustment including self-calibration with additional parameters for modeling systematic imaging errors was determined in the AICON 3D Studio software package (AICON 3D Systems GmbH, Germany). The optimal correction terms contain additional parameters for the compensation of radial-symmetric A1, A2 lens distortion and radial-asymmetric tangential B1, B2 lens distortion as well as affinity C1 and shear of the digital sensor coordinate system C2. High-pass filtering of blurred digital images (blur r = 2) is essential for measurement of structural signalized points using center weighted method. In the case of significantly blurred images (blur r = 3) the typical Laplace filters do not sharpen the images to the extend enabling measurement. Laplacian of Gauss (mask 5×5 pixel) turned out to be the only efficient high-pass filter. The low-pass filtering and nonlinear median filter of noisy digital images does not influence the measurement accuracy and values of adjusted parameters. The center weighted operator is robust in the structural signalized points measurement on the insignificantly blurred images and is resistant to occurrences of random noises. In all of the analyzed variants Sigma 0 mean value after the combined bundle adjustment with the self-calibration amounted to σ0 = 0.07 pixel (sensor pixel size p’HV = 7.9 μm). The RMS image coordinates residuals after adjustment amounted to RMS Vx' = 0.05 pixel and RMS Vy' = 0.06 pixel and the RMS standard deviation of calculated object coordinates respectively amounted to: RMS SX = 0.05 mm, RMS SY = 0.1 mm, RMS SZ = 0.04 mm.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2012, 24; 333-343
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration low-cost cameras with wide-angle lenses for measurements
Autorzy:
Wierzbicki, D.
Powiązania:
https://bibliotekanauki.pl/articles/384304.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
sensors
measurements
camera calibration
videos
accuracy
czujnik
pomiary
kalibracja kamery
filmy video
precyzja
Opis:
So far too many examinations concerning the possibility of the application action cameras weren’t conducted in UAV photogrammetric studies. However in the recent time development of the action cameras production technology he let receive sensors which are light, userfriendly, and most importantly can gain images and video sequences of high resolution. The essential meaning has taking into account the camera’s influencing factors in UAV photogrammetry. Due to the fact that the action cameras are non-metric cameras the significant influence on the quality of photogrammetric studies has a stability internal orientation of elements of such cameras. Within the framework of carried out research calibration of five GoPro Hero 4 Black. The calibration of cameras was carried out on different calibration tests in the GML Camera Calibration Toolbox and Agisoft Lens software. Different calibration setups and processing are presented and discussed in this article. Additionally a repetitiveness of achieved results of the calibration was examined in five GoPro cameras Hero 4 Black. Dedicated calibration templates in the form of chessboards were used to the calibration. As a part of the research a comparative analysis of the results have been done. Based on performed examinations a repetitiveness of determined internal orientation elements was checked under different video acquisition modes.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2018, 12, 2; 45-51
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of Altitude Accuracy of Punctual Celestial Bodies Measured with Help of Digital Still Camera
Autorzy:
Bobkiewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/116884.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Morski w Gdyni. Wydział Nawigacyjny
Tematy:
Astronavigation
Altitude Accuracy
Celestial Navigation
Digital Still Camera
Sextant
Calibration
Celestial Bodies
Accuracy of Position
Opis:
Measurement of altitude traditionally made with sextant may be done with help of digital still camera. Factors influencing accuracy of this measurement done with help of such a device are described in the paper. Values of errors introduced by each of these factors are estimated basing on example technical data of typical digital camera. This analysis shows, which factors are the most important and if accuracy of altitude is sufficient for purposes of celestial navigation.
Źródło:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation; 2008, 2, 3; 279-284
2083-6473
2083-6481
Pojawia się w:
TransNav : International Journal on Marine Navigation and Safety of Sea Transportation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of power losses in a high-frequency planar transformer using a thermal camera
Autorzy:
Barlik, R.
Nowak, M.
Grzejszczak, P.
Zdanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/140759.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power losses estimation
thermal camera
thermal calibration
planar transformer
Dowell’s and Steinmetz’s equations
Opis:
This paper presents the implementation of a thermal camera for the quantitative estimation of power losses in a high frequency planar transformer (100 kHz/ 5600 VA). The methodology is based on the observation of the transient temperature rise and determination of the power losses by means of curves representing the derivative of temperature as a function of power losses dissipated in the transformer. First, the thermal calibration characteristics had to be obtained from a simple experiment, where power losses are generated by DC current in the ferrite core and windings. Next, experimental investigations focused on the determination of the transformer power losses for a short circuit and no load, with a resistive load and with the rectifier as a load were carried out. Finally, to verify the obtained results, analytical calculations based on Dowell’s and modified Steinmetz’s equations were additionally made, which showed a good convergence. The proposed method is easy to implement and can be used as an alternative to the calorimetric method which is time-consuming and requires a complicated measurement setup.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 613-627
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examining the impact of recording long-series images taken from non-metric cameras on optimisation of modelling process and 3D visualisations
Badanie wpływu seryjnej rejestracji obrazów z kamer niemetrycznych na optymalizację procesu modelowania i wizualizacji 3D
Autorzy:
Jankowicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/100280.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
recording of long-series images
non-metric camera
calibration
3D modelling
rejestracja wielkoseryjna obrazów
kamera niemetryczna
kalibracja
modelowanie 3D
Opis:
In spite of the diversity of methods used in acquiring data images and later in the modelling process and spatial visualisation it is worthwhile to seek for alternative methods of optimizing the applied technique and processing method. Adopting costly solutions is not always necessary. For the purposes of terrain analysis and local assessments of landscape the author suggest to use the modelling method based on recording series images taken by non-metric cameras, guaranteeing economical, technically optimal and accurate solution of the problem. This claim is proven by the accuracy analyses of generated spatial visualisations and the results of calibration of chosen non-metric cameras. The study confirmed the consistency of the results of control measurements - carried out by means of analyses of calibration reports in chosen non-metric cameras and an exemplary objects spatial model created by a separate software - with the predictions made in the stage of theoretical considerations.
Mimo różnorodności metod stosowanych zarówno przy pozyskiwaniu danych obrazowych jak i później podczas procesu modelowania i wizualizacji przestrzennej, warto poszukiwać alternatywnych metod celem optymalizacji przyjętej techniki i metodyki opracowania. Nie zawsze konieczne jest użycie kosztownych rozwiązań. Dla celów analiz terenu i lokalnych ocen krajobrazu autor proponuje zastosowanie metodyki modelowania, opartej na wielkoseryjnej (rozwinięcie seryjnej) rejestracji obrazów cyfrowych z kamer niemetrycznych, zapewniając jednocześnie ekonomiczne i optymalne techniczno-dokładnościowe rozwiązanie problemu, czego dowodem oprócz analiz dokładnościowych wygenerowanych wizualizacji przestrzennych, są wyniki kalibracji wybranych kamer niemetrycznych. Mając na uwadze rezultaty badań, potwierdzono zgodność wyników pomiarów kontrolnych, przeprowadzonych za pośrednictwem analiz raportów kalibracji wybranych kamer niemetrycznych jak i przykładowego modelu przestrzennego obiektu, opracowanego na bazie odrębnego software’u, z przewidywaniami, które pojawiły się na etapie rozważań teoretycznych.
Źródło:
Geomatics, Landmanagement and Landscape; 2016, 2; 41-47
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja kamer z zastosowanym warunkiem Scheimpfluga
Camera calibration with Scheimpflug condition
Autorzy:
Tokarczyk, R.
Jędrzejek, M.
Powiązania:
https://bibliotekanauki.pl/articles/130084.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
fotogrametria bliskiego zasięgu
kalibracja kamery
warunek Scheimpfluga
dystorsja obiektywu
close-range photogrammetry
camera calibration
Scheimpflug condition
lens distortion
Opis:
Zastosowanie warunku Scheimpfluga w kamerach powoduje, że dystorsja obiektywu nie jest symetryczna wokół punktu głównego zdjęcia, a przyjęcie tego punktu jako początku promieni radialnych dla dystorsji powoduje znaczące obniżenie dokładności fotogrametrycznego pomiaru. Dodatkowo, zmienia się charakter dystorsji, jej zniekształcenie nie jest kołowe, a eliptyczne. Dotychczasowe rozwiązania problemu polegają na dodaniu do parametrów kalibracji kamery kąta nachylenia płaszczyzny rejestracji w stosunku do płaszczyzn głównych obiektywu kamery i wyznaczenie ich w procesie wyrównania sieci z samokalibracją. W przypadkach stosowania metod jednoobrazowych, wykorzystywanych na przykład w pomiarach z zastosowaniem profili świetlnych, znajomość parametrów kalibracji można ograniczyć tylko do błędów obrazu – przede wszystkim do wpływu dystorsji obiektywu. W pracy podano proste obliczeniowo metody wyznaczenia błędów obrazu dla zdjęć wykonanych kamerą z warunkiem Scheimpfluga. Pierwszy polega na wyznaczeniu wyinterpolowanych poprawek do pomierzonych współrzędnych w oparciu o „mapę” odchyłek otrzymaną na podstawie przekształcenia rzutowego płaskiego wielopunktowego pola testowego na zdjęcie. Druga metoda wymaga obliczenia oprócz parametrów dystorsji również punktu najlepszej symetrii dystorsji wykorzystując odchyłki po transformacji rzutowej. Badania wykonano w oparciu o dane rzeczywiste, jak i symulacyjne. Rezultaty usunięcia wpływu dystorsji pierwszą z metod okazały się znacznie lepsze od drugiej metody, pozwoliły na zmniejszenie wpływu błędu dystorsji do poziomu błędów przypadkowych pomiaru.
Automatic processes of manufacturing supervision with digital cameras often need to employ the Scheimpflug condition. This is quite common when registering profiles with a laser light. The Scheimplug condition is applied in this case because usually the registration plane cannot be set in parallel to the plane of a laser profile. Moreover, the low-light conditions forcing the use of large diaphragm size and low image acquisition distance imply that the depth of field is insufficient. Setting up three planes: lens main, image and profile in a way that they intersect within one edge, causes that the axis of the lens impales image plane at a point distant from the principal point, which in the analytical evaluation of the photogrammetric networks is adopted as the best-distortionsymmetry point. The Scheimpflug condition causes that the lens distortion (a feature significantly influencing the central projection) is not symmetrical around the principal point and, assuming this point as the origin of radial rays, leads to significant reduction of accuracy of measurement. A solution to this problem is to include the incidence angle between the detector array and lens main planes in the calibration parameters and their evaluation in the self-calibration network adjustment. This best solution from the substantive point of view thus needs elaboration of a specific software for self-calibration bundle adjustment, which is costly and time consuming. In this paper the different – computationally easier methods for the evaluation of image errors for the images taken considering the use of a camera with the Scheimpflug condition. The first method involves determination of interpolated corrections to measured coordinates based on a “deviation map” obtained from the projective transform of a planar, multi-point test-field on the image. The second method employs the evaluation of the best-distortion-symmetry point using the deviations evaluated after the projective transform, approximated by a radial and tangential distortion polynomial evaluated regarding this point. The research was conducted using real as well as simulated data.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2010, 21; 385-394
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja równoczesna aparatu cyfrowego Kodak DC4800 w procesie fotogrametrycznego pomiaru punktów w bliskim zasięgu
Simultaneous calibration of a digital camera Kodak DC4800 in close range photogrammetric point measurement
Autorzy:
Sawicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/131238.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
kamera cyfrowa
kalibracja
parametry
pomiar
bliski zasięg
digital camera
calibration
parameters
measurement
close range
Opis:
W fotogrametrii bliskiego zasięgu aktualnym zagadnieniem jest badanie technik kalibracji oraz praktycznych możliwości zastosowania niemetrycznych aparatów cyfrowych typu compact w pomiarach metrologicznych, rekonstrukcji inżynierskiej as-built, w inwentaryzacji architektonicznej etc. Możliwości i warunki kalibracji aparatu cyfrowego typu compact Kodak DC 4800 o rozdzielczości 2.2 K × 1.4 K pikseli, badano w warunkach praktycznego pomiaru przemysłowego kotła parowego. 24 fotopunkty wyznaczono z dokładnością mX,Z = ±0.2 mm i mY = ±0.3 mm. Wykonano 16 zdjęć słabo zbieżnych. Punkty na obrazach cyfrowych pomierzono w trybie semiautomatycznym metodą matching’u LSM i manualnie. Kalibrację aparatu cyfrowego wykonano przy użyciu metody kalibracji równoczesnej on-the-job, stosując model korekcji błędów systematycznych wg Luhmann’a. Parametry kalibracji aparatu cyfrowego i terratriangulację rozwiązano metodą wiązek przy użyciu programu PICTRAN B. W procesie kalibracji równoczesnej występują istotne korelacje między wyznaczanymi parametrami, co nie obniża dokładności fotogrametrycznego wyznaczenia współrzędnych punktów. Użycie tych parametrów jako stałe do innych rozwiązań spowoduje zafałszowanie wyników obliczeń. Metoda kalibracji równoczesnej on-the-job niemetrycznego aparatu cyfrowego najdokładniej odpowiada rzeczywistym warunkom rejestracji i reprezentuje optymalny model funkcjonalny analitycznego opracowania. Metoda ta umożliwia otrzymanie najwyższej dokładności fotogrametrycznego wyznaczenia punktów.
A current issue in close range photogtammetry is the calibration of non-metric digital cameras and their use for photogrammetric points measurement. In the research the test object, i.e. an industrial steam boiler and its technical infrastructure, was recorded using a non-metric digital camera of the compact type Kodak DC4800 with 2.2 K × 1.4 K resolution, to realize as-built documentation. The digital camera was calibrated by means of the simultaneous on-the-job calibration method. The calibration model allowing to determine the interior orientation cK , x′0 , y′0 and additional parameters modeling systematic errors of digital imaging, i.e., radial symmetric lens distortion A1 and A2 , tangential B1 and decentring distortion B2 , scale factor C1 in x and shear C2 , has been formulated by Luhmann. The phototriangulation of digital images with simultaneous calibration of digital camera was solved by means of a combined bundle adjustment of observations using the PICTRAN B software. The results obtained and the accuracy of digital camera simultaneous calibration are discussed in the paper. The simultaneous on-the-job calibration of a digital non-metric camera exactly fulfills real conditions of registration and represents an adequate functional model for analytical elaboration. It enables obtaining the highest accuracy of photogrammetric point measurement.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2003, 13b; 457-466
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja systemów stereowizyjnych przy użyciu odpornej metody podwójnej płaszczyzny
Robust double-plane calibration of stereovision systems
Autorzy:
Rotter, P.
Byrski, W.
Dajda, M.
Powiązania:
https://bibliotekanauki.pl/articles/274599.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
stereowizja
kalibracja kamer
metoda podwójnej płaszczyzny
stereovision
camera calibration
double-plane method
Opis:
W metodzie podwójnej płaszczyzny (ang. double plane) zależność między współrzędnymi obrazowymi a współrzędnymi w przestrzeni trójwymiarowej jest obliczana na podstawie czterech przekształceń płaszczyzny na płaszczyznę (dwie kamery i dwie płaszczyzny kalibracyjne). Metoda jest intuicyjna i łatwa w implementacji, lecz ma poważną wadę w postaci złego uwarunkowania zadania dla pewnych obszarów przestrzeni. W artykule proponujemy odporną metodę kalibracji, która wykorzystuje dodatkowo trzecią płaszczyznę kalibracyjną. Jest to płaszczyzna wirtualna, która nie jest fizycznie elementem wzorca, ale jest zdefiniowana przez odpowiednio rozmieszczone punkty kalibracyjne na dwóch płaszczyznach podstawowych. Proponowany algorytm wykorzystuje liniową kombinację trzech par płaszczyzn: dla par płaszczyzn, które mogą generować błędy numeryczne przypisywana jest niska waga, minimalizująca ich wpływ na wynik końcowy. Eksperymenty wykazały dużą dokładność i wiarygodność proponowanej metody w stosunku do podstawowej wersji algorytmu: błąd średniokwadratowy i błąd maksymalny zostały zredukowane odpowiednio 4- i 20-krotnie.
In double-plane method for stereovision system calibration the correspondence between screen coordinates and location in 3D space is calculated based on four plane-to-plane transformations: there are two planes of the calibration pattern and two cameras. The method is intuitive and easy to implement but the main disadvantage is ill-conditioning for some spatial locations. In this paper we proposed a robust method which exploits the third plane which physically does not belong to the calibration pattern but can be calculated from the set of reference points. Our algorithm uses combination of three calibration planes with weights which depend on screen coordinates of the point of interest: a pair of planes which could cause numerical errors receives small weight and has practically no inl uence on the i nal results. We analysed errors and their distribution in 3D space for basic and improved algorithm. Experiments demonstrate high accuracy and reliability of our method comparing to the basic version: mean square error and maximum error are reduced 4 times and 20 times respectively.
Źródło:
Pomiary Automatyka Robotyka; 2011, 15, 12; 121-126
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies